10    For TT Transfer Interface Select                  Y Y Y S Y Y N N     YNNNNYYNNNNYNNNNYNNNNNNYY YNNNNYYNNNNYNNNNYNNNNNNYY
          GREYSTON     CL     BK 1 DI  230 KV    DIS            .000         .000      P
          GREYSTON     CL     S1007 AC 230 KV    CB             .000         .000      P
          GREYSTON     CL     Q1031 AC 230 KV    CB             .000         .000      P
   20    69/23.Cedar.T1                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CEDAR        X      XFR T1   69 KV                    .000         .000      P
          CEDAR        OP     GCB BB   69 KV     CB             .000         .000      P
          CEDAR        OP     OCB F    23 KV     CB             .000         .000      P
   30    69/23.Cedar.T2                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CEDAR        X      XFR T2   69 KV                    .000         .000      P
          CEDAR        OP     OCB E    23 KV     CB             .000         .000      P
          CEDAR        OP     GCB AA   69 KV     CB             .000         .000      P
   60    L69.Lewis-MossMill.0701                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LEWIS        OP     DT CB    69 KV     CB             .000         .000      P
          MOSSMILL     OP     N        69 KV     CB             .000         .000      P
          MOSSMILL     OP     M        69 KV     CB             .000         .000      P
          LEWIS        L      LEW-MOSS 69 KV                    .000         .000      P
   70    L69.Cedar-Motts.0770                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CEDAR        OP     GCB B    69 KV     CB             .000         .000      P
          CEDAR        L      CED-MOT5 69 KV                    .000         .000      P
          MOTTS        OP     F        69 KV     CB             .000         .000      P
   80    L69.Cedar-ShipBottom.0767                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CEDAR        OP     GCB HS   69 KV     CB             .000         .000      P
          CEDAR        OP     GCB GQ   69 KV     CB             .000         .000      P
          SHIPBOTT     OP     GCB J    69 KV     CB             .000         .000      P
          SHIPBOTT     OP     GCB F    69 KV     CB             .000         .000      P
          CEDAR        L      CED-SHI  69 KV                    .000         .000      P
   90    L69.Cedar-ShipBottom.0766                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHIPBOTT     OP     GCB C    69 KV     CB             .000         .000       
          CEDAR        OP     FF CB    69 KV     CB             .000         .000       
          SHIPBOTT     OP     GCB E    69 KV     CB             .000         .000       
          CEDAR        OP     GCB KM   69 KV     CB             .000         .000       
          CEDAR        L      CED-SHI2 69 KV                    .000         .000       
  100    L69.Cedar-Barnegate.0777                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BARNEGAT     OP     H        69 KV     CB             .000         .000       
          CEDAR        OP     GCB ES   69 KV     CB             .000         .000       
          CEDAR        OP     OCB D    69 KV     CB             .000         .000       
          BARNEGAT     OP     CB A     69 KV     CB             .000         .000       
          BARNEGAT     L      BAR-CED1 69 KV                    .000         .000       
  110    L69.Cedar-Barnegate.0791                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BARNEGAT     OP     G        69 KV     CB             .000         .000       
          CEDAR        OP     GCB IO   69 KV     CB             .000         .000       
          BARNEGAT     L      BAR-CED2 69 KV                    .000         .000       
          BARNEGAT     OP     F        69 KV     CB             .000         .000       
          CEDAR        OP     GCB HS   69 KV     CB             .000         .000       
  120    L69.Lewis-Absecon.0702                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ABSECON      OP     M        69 KV     CB             .000         .000      P
          LEWIS        OP     OCB G    69 KV     CB             .000         .000      P
          ABSECON      CL     L        69 KV     CB             .000         .000      P
          ABSECON      OP     LEWIS    69 KV     DIS            .000         .000      P
          ABSECON      S      SERIES1  69 KV                    .000         .000      P
          ABSECON      L      ABS-LEW1 69 KV                    .000         .000      P
  130    L69.Lewis-Higbee.0751                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LEWIS        L      HIG-LEWI 69 KV                    .000         .000      P
          HIGBEE       OP     OCB H    69 KV     CB             .000         .000      P
          LEWIS        OP     OCB J    69 KV     CB             .000         .000      P
  140    L69.Lewis-Higbee.0741                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HIGBEE       L      HIG-LEW1 69 KV                    .000         .000      P
          HIGBEE       OP     OCB B    69 KV     CB             .000         .000      P
          LEWIS        OP     OCB S    69 KV     CB             .000         .000      P
  150    L69.Lewis-Ontario.0742                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ONTARIO      OP     OCB B    69 KV     CB             .000         .000      P
          LEWIS        OP     F        69 KV     CB             .000         .000      P
          LEWIS        L      LEW-ONT2 69 KV                    .000         .000      P
          LEWIS        OP     GCB KM   69 KV     CB             .000         .000      P
  160    L69.Higbee-Ontario.0772                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ONTARIO      OP     OCB A    69 KV     CB             .000         .000      P
          HIGBEE       OP     OCB E    69 KV     CB             .000         .000      P
          HIGBEE       L      HIG-ONT  69 KV                    .000         .000      P
  170    L69.Mill-Marven.0749                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MARVENAE     L      MAR-MILL 69 KV                    .000         .000      P
          MARVENAE     OP     J        69 KV     CB             .000         .000      P
          MARVENAE     OP     D        69 KV     CB             .000         .000      P
          MILL         OP     OCB B    69 KV     CB             .000         .000      P
  190    L69.Lewis-Lenox.0721                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LEWIS        OP     R        69 KV     CB             .000         .000      P
          LENOX AE     OP     OCB L    69 KV     CB             .000         .000      P
          LENOX AE     L      LEN-LEW  69 KV                    .000         .000      P
  200    L69.Lenox-EggHarbor.0794                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EGGHARBO     OP     E CB     69 KV     CB             .000         .000      P
          EGGHARBO     OP     A CB     69 KV     CB             .000         .000      P
          LENOX AE     L      EGG-LEN  69 KV                    .000         .000      P
          LENOX AE     OP     OCB D    69 KV     CB             .000         .000      P
  210    L69.Monroe-WinslowA-Dacosta.0731                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WINSLOWA     L      WIN-WINA 69 KV                    .000         .000      P
          DACOSTA      OP     OCB M    69 KV     CB             .000         .000      P
          MONR AE      OP     OCB A    69 KV     CB             .000         .000      P
          DACOSTA      L      DAC-WIN  69 KV                    .000         .000      P
          WINSLOWA     L      MON-WINA 69 KV                    .000         .000      P
  220    L69.Monroe-Vineland.0711                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          VINELAND     OP     OCB U    69 KV     CB             .000         .000      P
          MONR AE      OP     OCB L    69 KV     CB             .000         .000      P
          MONR AE      L      MON-VINE 69 KV                    .000         .000      P
  230    L69.Butler-Vineland.0789                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          VINELAND     OP     OCB D    69 KV     CB             .000         .000      P
          BUTLER       L      BUT-VIN  69 KV                    .000         .000      P
          BUTLER       OP     OCB M    69 KV     CB             .000         .000      P
  240    L69.Sherman-Vineland.0761                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHERMAN      OP     OCB C    69 KV     CB             .000         .000      P
          VINELAND     OP     OCB A    69 KV     CB             .000         .000      P
          SHERMAN      L      SHE-VIN  69 KV                    .000         .000      P
  250    L69.Sherman-SecondSt.0757                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHERMAN      OP     OCB J    69 KV     CB             .000         .000      P
          SECONDST     L      SEC-SHE1 69 KV                    .000         .000      P
          SECONDST     OP     OCB H    69 KV     CB             .000         .000      P
  260    L69.Sherman-SecondSt.0758                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SECONDST     OP     OCB K    69 KV     CB             .000         .000      P
          SECONDST     L      SEC-SHE2 69 KV                    .000         .000      P
          SHERMAN      OP     OCB A    69 KV     CB             .000         .000      P
  270    L69.SecondSt-SouthMillville.0733                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SECONDST     OP     OCB L    69 KV     CB             .000         .000      P
          SECONDST     L      SEC-SML  69 KV                    .000         .000      P
          SMILLVIL     OP     OCB A    69 KV     CB             .000         .000      P
  280    L69.Butler-Lincoln.0764                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BUTLER       L      BUT-LINC 69 KV                    .000         .000      P
          LINCOLN3     OP     L        69 KV     CB             .000         .000      P
          LINCOLN3     OP     J        69 KV     CB             .000         .000      P
          BUTLER       OP     P        69 KV     CB             .000         .000      P
  290    L69.Newport-SouthMillville.0762                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SMILLVIL     OP     OCB B    69 KV     CB             .000         .000      P
          NEWPORT      L      NEW-SML  69 KV                    .000         .000      P
          NEWPORT      OP     OCB H    69 KV     CB             .000         .000      P
  300    L69.Fairton-Newport.0727                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FAIRTON      OP     OCB G    69 KV     CB             .000         .000      P
          FAIRTON      L      FAI-NEW  69 KV                    .000         .000      P
          NEWPORT      OP     OCB G    69 KV     CB             .000         .000      P
  310    L69.Laurel-Fairton.0708                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LAUREL       OP     OCB E    69 KV     CB             .000         .000      P
          FAIRTON      L      FAI-LAU  69 KV                    .000         .000      P
          FAIRTON      OP     OCB A    69 KV     CB             .000         .000      P
  320    L69.CarllsCorner-Laurel.0709                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARLLS       L      CAR-LAU  69 KV                    .000         .000      P
          CARLLS       OP     OCB C    69 KV     CB             .000         .000      P
          LAUREL       OP     OCB A    69 KV     CB             .000         .000      P
  330    CarllsCorner.CT1                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARLLS       U      CT_1     69 KV                    .000         .000      P
          CARLLS       OP     G        69 KV     DIS            .000         .000      P
  340    CarllsCorner.CT2                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARLLS       U      CT_2     69 KV                    .000         .000      P
          CARLLS       OP     H        69 KV     DIS            .000         .000      P
  350    L69.CarllsCorner-Sherman.0739                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARLLS       OP     OCB D    69 KV     CB             .000         .000      P
          SHERMAN      OP     OCB H    69 KV     CB             .000         .000      P
          CARLLS       L      CAR-SHE  69 KV                    .000         .000      P
  360    L69.Butler-Sherman.0778                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BUTLER       L      BUT-SHE  69 KV                    .000         .000      P
          BUTLER       OP     OCB K    69 KV     CB             .000         .000      P
          SHERMAN      OP     OCB M    69 KV     CB             .000         .000      P
  370    L69.Quinton-Roadstown.1723-2                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROADSTOW     OP     B CB     69 KV     CB             .000         .000      P
          QUINTON      OP     H CB     69 KV     CB             .000         .000      P
          QUINTON      L      QUI-ROA  69 KV                    .000         .000      P
  390    L69.Laurel-Woodstown.0740                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LAUREL       L      LAU-WOO  69 KV                    .000         .000      P
          WOODSTOW     OP     OCB S    69 KV     CB             .000         .000      P
          LAUREL       OP     OCB C    69 KV     CB             .000         .000      P
  400    L69.Clayton-Woodstown.0714                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WOODSTOW     OP     OCB F    69 KV     CB             .000         .000      P
          CLAYTNAE     OP     OCB E    69 KV     CB             .000         .000      P
          CLAYTNAE     L      CLA-WOO  69 KV                    .000         .000      P
  410    L69.Monroe-WilliamsT-Clayton.0716                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WILLIAMT     L      WIL-WILT 69 KV                    .000         .000      P
          CLAYTNAE     L      CLA-WIL  69 KV                    .000         .000      P
          MONR AE      OP     OCB B    69 KV     CB             .000         .000      P
          CLAYTNAE     OP     OCB D    69 KV     CB             .000         .000      P
          MONR AE      L      MON-WIL  69 KV                    .000         .000      P
  420    L69.Churchtown-Deepwater.0788                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DEEPWATE     OP     GCB 6626 69 KV     CB             .000         .000      P
          CHURCHTO     L      CHU-DEE  69 KV                    .000         .000      P
          CHURCHTO     OP     BV       69 KV     CB             .000         .000      P
  430    L69.Deepwater-Beckett-Paulsboro.0722              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BECKETT      LD     LOAD1    69 KV                    .000         .000      P
          DEEPWATE     OP     OCB 6624 69 KV     CB             .000         .000      P
          PAULSBRO     OP     OCB P    69 KV     CB             .000         .000      P
          BECKETT      L      BEC-DEE  69 KV                    .000         .000      P
          BECKETT      L      BEC-PAU  69 KV                    .000         .000      P
          BECKETT      LD     LOAD2    69 KV                    .000         .000      P
  440    L69.Deepwater-Salem.0724                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DEEPWATE     L      DEE-SAL  69 KV                    .000         .000      P
          SALEM AE     OP     DIS S    69 KV     DIS            .000         .000      P
          DEEPWATE     OP     OCB 6622 69 KV     CB             .000         .000      P
          SALEM AE     CL     DIS G    69 KV     DIS            .000         .000      P
  450    L69.Woodstown-Salem.0745                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SALEM AE     OP     DIS R    69 KV     DIS            .000         .000      P
          WOODSTOW     OP     OCB W    69 KV     CB             .000         .000      P
          SALEM AE     CL     DIS G    69 KV     DIS            .000         .000      P
          SALEM AE     L      SAL-WOO  69 KV                    .000         .000      P
  460    L69.Woodstown-Churchtown.0725                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WOODSTOW     OP     OCB E    69 KV     CB             .000         .000      P
          CHURCHTO     OP     JN       69 KV     CB             .000         .000      P
          CHURCHTO     OP     LM       69 KV     CB             .000         .000      P
          CHURCHTO     L      CHU-WOO5 69 KV                    .000         .000      P
  470    L69.Woodstown-Churchtown.0726                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHURCHTO     OP     HP       69 KV     CB             .000         .000      P
          WOODSTOW     OP     OCB R    69 KV     CB             .000         .000      P
          CHURCHTO     L      CHU-WOO6 69 KV                    .000         .000      P
          CHURCHTO     OP     GQ       69 KV     CB             .000         .000      P
  480    L69.Pitman-Washington.0753                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PITMAN       L      PIT-WAS  69 KV                    .000         .000      P
          WASHINGT     OP     GCB D    69 KV     CB             .000         .000      P
          PITMAN       OP     OCB A    69 KV     CB             .000         .000      P
  490    L69.Monroe-Washington.0786                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MONR AE      L      MON-WAS  69 KV                    .000         .000      P
          WASHINGT     OP     GCB B    69 KV     CB             .000         .000      P
          MONR AE      OP     OCB U    69 KV     CB             .000         .000      P
  500    L69.Monroe-Sickler.0732                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MONR AE      L      MON-SIC  69 KV                    .000         .000       
          SICKLER      OP     OCB C    69 KV     CB             .000         .000       
          MONR AE      OP     OCB G    69 KV     CB             .000         .000       
  510    L69.Mickleton-River.0747                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MICKLETO     L      MIC-RIV  69 KV                    .000         .000       
          RIVER        OP     OCB B    69 KV     CB             .000         .000       
          MICKLETO     OP     OCB A    69 KV     CB             .000         .000       
  520    L69.Mickleton-ValeroTap-Paulsboro.0746            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MICKLETO     L      MIC-VALT 69 KV                    .000         .000       
          VALERO       OP     OCB 1    69 KV     CB             .000         .000       
          PAULSBRO     OP     OCB O    69 KV     CB             .000         .000       
          PAULSBRO     L      PAU-VALT 69 KV                    .000         .000       
          MICKLETO     OP     OCB C    69 KV     CB             .000         .000       
          VALERO       L      VAL-VALT 69 KV                    .000         .000       
  530    L69.Paulsboro-Valero.0774                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PAULSBRO     OP     OCB Q    69 KV     CB             .000         .000       
          VALERO       OP     DUM19014 69 KV     DIS            .000         .000       
          PAULSBRO     L      PAU-VAL  69 KV                    .000         .000       
  540    L69.Monsanto-Nortonville-Oldman.0705              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NORTONVL     OP     A        69 KV     DIS            .000         .000       
          NORTONVL     OP     KL       69 KV     DIS            .000         .000       
          NORTONVL     L      NOR-OLDM 69 KV                    .000         .000       
          MONSANTO     L      MON-NORT 69 KV                    .000         .000       
          NORTONVL     OP     JK       69 KV     DIS            .000         .000       
          MONSANTO     OP     OCB B    69 KV     CB             .000         .000       
          NORTONVL     LD     T2 LOAD  69 KV                    .000         .000       
          OLDMAN       OP     B        69 KV     CB             .000         .000       
          NORTONVL     OP     B        69 KV     DIS            .000         .000       
  550    L69.Oldman-PennsGrove.0704                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OLDMAN       L      OLD-PEN  69 KV                    .000         .000       
          PENNSGRO     OP     OCB A    69 KV     CB             .000         .000       
          OLDMAN       OP     A        69 KV     CB             .000         .000       
  560    L69.Monsanto-River.0763                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RIVER        OP     OCB C    69 KV     CB             .000         .000       
          MONSANTO     OP     OCB A    69 KV     CB             .000         .000       
          MONSANTO     L      MON-RIV  69 KV                    .000         .000       
  570    Mickleton.CT1                                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MICKLETO     OP     DIS N    69 KV     DIS            .000         .000       
          MICKLETO     U      CT_1     69 KV                    .000         .000       
  580    L138.England-Scull-Mill.1407                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ENGLAND      L      ENG-SCU7 138 KV                   .000         .000       
          MILL         L      MIL-SC_7 138 KV                   .000         .000       
          MILL         OP     A        138 KV    CB             .000         .000       
          ENGLAND      OP     452-G    138 KV    CB             .000         .000       
          SCULL        LD     BUS1     138 KV                   .000         .000       
          MILL         OP     O        138 KV    CB             .000         .000       
  610    L138.Corson-Merion.1411                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CORSON       OP     E        138 KV    CB             .000         .000       
          MERION       OP     DS D     138 KV    DIS            .000         .000       
          CORSON       L      COR-MER  138 KV                   .000         .000       
  620    L138.England-Merion.1401                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MERION       OP     DS E     138 KV    DIS            .000         .000      P
          ENGLAND      OP     452-C    138 KV    CB             .000         .000      P
          ENGLAND      L      ENG-MER  138 KV                   .000         .000      P
  630    L138.Corson-MiddleTap-England.1403                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MIDD AE      X      MID #4   138 KV                   .000         .000      P
          CORSON       L      COR-MDT  138 KV                   .000         .000      P
          ENGLAND      L      ENG-MDT  138 KV                   .000         .000      P
          MIDDLTAP     OP     OCB G    138 KV    CB             .000         .000      P
          CORSON       OP     OCB R    138 KV    CB             .000         .000      P
          MIDDLTAP     L      MID-MDT  138 KV                   .000         .000      P
          ENGLAND      OP     452-D    138 KV    CB             .000         .000      P
  640    L138.Corson-Middle.1412 + 138/69.Middle.T3        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MIDD AE      X      MID #3   138 KV                   .000         .000      P
          CORSON       OP     OCB Q    138 KV    CB             .000         .000      P
          MIDD AE      OP     XFMROCBE 69 KV     CB             .000         .000      P
          CORSON       L      COR-MID  138 KV                   .000         .000      P
  650    L138.Middle-MiddleTap.1413 + 138/69.Middle.T4     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MIDD AE      X      MID #4   138 KV                   .000         .000      P
          MIDD AE      OP     XFMROCBL 69 KV     CB             .000         .000      P
          MIDDLTAP     L      MID-MDT  138 KV                   .000         .000      P
          MIDDLTAP     OP     OCB G    138 KV    CB             .000         .000      P
  660    L138.Corson-Union.1402                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CORSON       L      COR-UNI  138 KV                   .000         .000      P
          CORSON       OP     OCB S    138 KV    CB             .000         .000      P
          UNION        OP     C CB     138 KV    CB             .000         .000      P
  670    L138.Corson-Dennis.1417                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DENNIS       OP     GCB A    138 KV    CB             .000         .000      P
          DENNIS       X      T2       230 KV                   .000         .000      P
          CORSON       L      COR-DEN  138 KV                   .000         .000      P
          CORSON       OP     OCB-D    138 KV    CB             .000         .000      P
  680    L138.Cumberland-Union.1416                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CUMB AE      OP     BUSGCBF  138 KV    CB             .000         .000      P
          UNION        OP     D CB     138 KV    CB             .000         .000      P
          CUMB AE      L      CUM-UNI  138 KV                   .000         .000      P
          CUMB AE      OP     BUSGCBH  138 KV    CB             .000         .000      P
  690    L138.Cumberland-Sherman.1415                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CUMB AE      OP     BUSGCBD  138 KV    CB             .000         .000      P
          CUMB AE      OP     BUSGCBE  138 KV    CB             .000         .000      P
          CUMB AE      L      CUM-SHE  138 KV                   .000         .000      P
          SHERMAN      OP     OCB S    138 KV    CB             .000         .000      P
  710    230/138.Cumberland.T2                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CUMB AE      OP     BUSGCBF  138 KV    CB             .000         .000      P
          CUMB AE      OP     BUSGCBB  230 KV    CB             .000         .000      P
          CUMB AE      X      CUMB #2  230 KV                   .000         .000      P
          CUMB AE      OP     BUSGCBC  230 KV    CB             .000         .000      P
          CUMB AE      OP     XFMRDISP 230 KV    DIS            .000         .000      P
          CUMB AE      OP     BUSGCBE  138 KV    CB             .000         .000      P
  720    Cumberland.CT1                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CUMB AE      X      GSU1     138 KV                   .000         .000      P
          CUMB AE      OP     BUSGCBL  138 KV    CB             .000         .000      P
          CUMB AE      OP     T1       138 KV    DIS            .000         .000      P
          CUMB AE      OP     BUSGCBH  138 KV    CB             .000         .000      P
          CUMB AE      LD     AUXLD1   13.8 KV                  .000         .000      P
          CUMB AE      U      CUMBCT   13.8 KV                  .000         .000      P
  760    L138.Churchtown-UpperPittsgrove.1405              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          UPPERPIT     OP     OCBE     138 KV    CB             .000         .000      P
          UPPERPIT     L      CHU-UPP  138 KV                   .000         .000      P
          CHURCHTO     X      T4       230 KV                   .000         .000      P
          CHURCHTO     OP     BB       138 KV    CB             .000         .000      P
  770    L138.Landis-UpperPittsgrove.1405-2                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LANDIS       L      LAN-UPP  138 KV                   .000         .000       
          LANDIS       OP     T        138 KV    CB             .000         .000       
          LANDIS       OP     J        138 KV    CB             .000         .000       
          UPPERPIT     OP     OCBA     138 KV    CB             .000         .000       
  790    L138.Monroe-Franklin.1420                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MONR AE      OP     XFMROCBH 138 KV    CB             .000         .000       
          FRANKAE      OP     D        138 KV    CB             .000         .000       
          FRANKAE      OP     C        138 KV    CB             .000         .000       
          MONR AE      OP     XFMROCBP 138 KV    CB             .000         .000       
          MONR AE      OP     GG       138 KV    DIS            .000         .000       
          FRANKAE      L      FRA-MONR 138 KV                   .000         .000       
  800    L138.Landis-Minotola.1409                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LANDIS       L      LAN-MIN  138 KV                   .000         .000       
          LANDIS       OP     N        138 KV    CB             .000         .000       
          MINOTOLA     OP     H CB     138 KV    CB             .000         .000       
          LANDIS       OP     W        138 KV    CB             .000         .000       
          MINOTOLA     OP     M CB     138 KV    CB             .000         .000       
  810    230/69.Churchtown.T1                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHURCHTO     OP     BUSGCBA  230 KV    CB             .000         .000       
          CHURCHTO     OP     B        230 KV    CB             .000         .000       
          CHURCHTO     OP     XFMRGCBD 69 KV     CB             .000         .000       
          CHURCHTO     X      CRCH #1  230 KV                   .000         .000       
  820    138/69.Lewis.T1                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LEWIS        OP     XFMROCBD 69 KV     CB             .000         .000       
          LEWIS        OP     XFMRABSM 138 KV    CB             .000         .000       
          LEWIS        X      LEW #1   138 KV                   .000         .000       
  830    138/69.Lewis.T3                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LEWIS        OP     HP CB    69 KV     CB             .000         .000      P
          LEWIS        X      LEW #3   138 KV                   .000         .000      P
          LEWIS        OP     IO DIS   138 KV    DIS            .000         .000      P
  840    138/69.Lewis.T2                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LEWIS        OP     XFMRABSN 138 KV    CB             .000         .000      P
          LEWIS        OP     XFMROCBE 69 KV     CB             .000         .000      P
          LEWIS        X      LEW #2   138 KV                   .000         .000      P
  850    138/69.Corson.T1                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CORSON       OP     XFMROCBJ 69 KV     CB             .000         .000      P
          CORSON       L      COR-MER  138 KV                   .000         .000      P
          CORSON       OP     BUSOCBT  138 KV    CB             .000         .000      P
          CORSON       OP     E        138 KV    CB             .000         .000      P
          CORSON       X      CORS #1  138 KV                   .000         .000      P
  860    138/69.Corson.T2                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CORSON       X      CORS #2  138 KV                   .000         .000      P
          CORSON       OP     DIS-F    138 KV    DIS            .000         .000      P
          CORSON       OP     XFMROCBA 69 KV     CB             .000         .000      P
  890    230/138.Churchtown.T4                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHURCHTO     X      T4       230 KV                   .000         .000      P
          CHURCHTO     OP     E        230 KV    CB             .000         .000      P
          CHURCHTO     OP     B        230 KV    CB             .000         .000      P
          CHURCHTO     L      CHU-UPP  138 KV                   .000         .000      P
          CHURCHTO     OP     BB       138 KV    CB             .000         .000      P
  910    138/69.Sherman.T2                                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHERMAN      OP     XFMROCBD 69 KV     CB             .000         .000       
          SHERMAN      OP     XFMRQBV  138 KV    CB             .000         .000       
          SHERMAN      X      SHER #2  138 KV                   .000         .000       
  920    138/69.Sherman.T3                                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHERMAN      X      SHER #3  138 KV                   .000         .000       
          SHERMAN      OP     XFMRQBW  138 KV    CB             .000         .000       
          SHERMAN      OP     XFMROCBL 69 KV     CB             .000         .000       
  930    L69.Mickleton-Mantua.0748                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MANTUA       L      MAN-MIC  69 KV                    .000         .000       
          MANTUA       OP     OCB A    69 KV     CB             .000         .000       
          MICKLETO     OP     GCB B    69 KV     CB             .000         .000       
  940    L69.Cardiff-Absecon-Lewis.0781                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARDIFF      OP     OCB G    69 KV     CB             .000         .000       
          ABSECON      CL     L        69 KV     CB             .000         .000       
          ABSECON      OP     K        69 KV     CB             .000         .000       
          LEWIS        OP     GQ CB    69 KV     CB             .000         .000       
          ABSECON      L      ABS-CAR  69 KV                    .000         .000       
          ABSECON      L      ABS-LEW  69 KV                    .000         .000       
  950    L69.Cardiff-Mill                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARDIFF      OP     GCB F    69 KV     CB             .000         .000       
          MILL         OP     XFMROCBJ 69 KV     CB             .000         .000       
          CARDIFF      L      CAR-MILL 69 KV                    .000         .000       
  970    Sherman.CT1                                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHERMAN      OP     OCB BV   138 KV    CB             .000         .000       
          SHERMAN      X      GSU1     138 KV                   .000         .000       
          SHERMAN      LD     AUXLD1   13.8 KV                  .000         .000       
          SHERMAN      U      CT 1     13.8 KV                  .000         .000       
  990    L230.Steele-Vienna.23085 & 230/138.Vienna.AT20    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          VIENNA       X      AT20     230 KV                   .000         .000       
          STEELE       OP     9230     230 KV    CB             .000         .000       
          STEELE       OP     252      230 KV    CB             .000         .000       
          STEELE       L      STE-VIE  230 KV                   .000         .000       
          VIENNA       OP     230      230 KV    CB             .000         .000       
 1000    230/138.CedarCreek.AT20                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CEDARCRE     X      AT20     230 KV                   .000         .000       
          CEDARCRE     OP     233      230 KV    CB             .000         .000       
          CEDARCRE     OP     137      138 KV    CB             .000         .000       
          CEDARCRE     OP     234      230 KV    CB             .000         .000       
          CEDARCRE     OP     130      138 KV    CB             .000         .000       
 1010    230/138.Milford.AT20                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MILFORD      OP     8610     138 KV    CB             .000         .000       
          MILFORD      OP     9380     230 KV    CB             .000         .000       
          MILFORD      X      AT20     230 KV                   .000         .000       
          MILFORD      OP     8640     138 KV    CB             .000         .000       
          MILFORD      OP     9390     230 KV    CB             .000         .000       
 1020    230/138.Vienna.AT20                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          VIENNA       X      AT20     230 KV                   .000         .000       
          VIENNA       OP     8130     138 KV    CB             .000         .000       
          VIENNA       OP     230      230 KV    CB             .000         .000       
          VIENNA       L      STE-VIE  230 KV                   .000         .000       
          VIENNA       OP     8140     138 KV    CB             .000         .000       
 1040    L138.Church-OilCity-Steele.13701                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STEELE       OP     8290     138 KV    CB             .000         .000       
          STEELE       OP     132      138 KV    CB             .000         .000       
          OILCITY      LD     LOAD1    138 KV                   .000         .000       
          CHURCH       L      CHU-OIL  138 KV                   .000         .000       
          CHURCH       OP     133      138 KV    CB             .000         .000       
          OILCITY      L      OIL-STE  138 KV                   .000         .000       
          CHURCH       OP     8430     138 KV    CB             .000         .000       
 1050    L138.IndianRiver-Frankford-Bishop.13719           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FRANKFOR     LD     FRANK    138 KV                   .000         .000       
          INDIANRI     OP     8040     138 KV    CB             .000         .000       
          INDIANRI     OP     8050     138 KV    CB             .000         .000       
          BISHOP       OP     165      138 KV    CB             .000         .000       
          FRANKFOR     L      FRA-IND  138 KV                   .000         .000       
          BISHOP       L      BIS-FRA  138 KV                   .000         .000       
          BISHOP       OP     164      138 KV    CB             .000         .000       
 1060    L138.Bishop-OceanBay.13786                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BISHOP       OP     161      138 KV    CB             .000         .000       
          OCEANBAY     OP     173      138 KV    CB             .000         .000       
          BISHOP       L      BIS-OCB  138 KV                   .000         .000       
          OCEANBAY     OP     172      138 KV    CB             .000         .000       
          BISHOP       OP     166      138 KV    CB             .000         .000       
 1070    L138.Bishop-Worcester.13779                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WORCESTE     X      AT1      138 KV                   .000         .000      P
          BISHOP       OP     164      138 KV    CB             .000         .000      P
          BISHOP       L      BIS-WOR  138 KV                   .000         .000      P
          WORCESTE     OP     195      138 KV    CB             .000         .000      P
          BISHOP       OP     162      138 KV    CB             .000         .000      P
 1080    L138.IndianRiver-Nelson.13703                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NELSON       OP     152      138 KV    CB             .000         .000      P
          NELSON       OP     155      138 KV    CB             .000         .000      P
          INDIANRI     OP     8070     138 KV    CB             .000         .000      P
          INDIANRI     L      IND-NEL  138 KV                   .000         .000      P
          INDIANRI     OP     8060     138 KV    CB             .000         .000      P
 1090    L138.IndianRiver-Omar-Roxana.13745                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OMAR         LD     LOAD1    138 KV                   .000         .000      P
          ROXANA       OP     131      138 KV    CB             .000         .000      P
          INDIANRI     L      IND-OMA  138 KV                   .000         .000      P
          ROXANA       OP     13745-L1 138 KV    DIS            .000         .000      P
          INDIANRI     OP     8010     138 KV    CB             .000         .000      P
          INDIANRI     OP     8000     138 KV    CB             .000         .000      P
          ROXANA       L      OMA-ROXA 138 KV                   .000         .000      P
          ROXANA       OP     130      138 KV    CB             .000         .000      P
 1100    L138.Bethany-138thSt.13732                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ST138        OP     130      138 KV    CB             .000         .000      P
          BETHANY      OP     134      138 KV    CB             .000         .000      P
          BETHANY      L      BET-ST1  138 KV                   .000         .000      P
          BETHANY      OP     132CB    138 KV    CB             .000         .000      P
 1110    L138.Nelson-Vienna.13707                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          VIENNA       OP     8180     138 KV    CB             .000         .000       
          NELSON       OP     154      138 KV    CB             .000         .000       
          NELSON       L      NEL-VIE  138 KV                   .000         .000       
          NELSON       OP     150      138 KV    CB             .000         .000       
          VIENNA       OP     8150     138 KV    CB             .000         .000       
 1120    Nelson.SVC                                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NELSON       U      SVC      138 KV                   .000         .000       
          NELSON       OP     151      138 KV    CB             .000         .000       
          NELSON       OP     155      138 KV    CB             .000         .000       
 1130    L138.Steele-Hillsboro-WyeMills.13761/13788        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STEELE       OP     131      138 KV    CB             .000         .000       
          WYEMILLS     OP     130 CB   138 KV    CB             .000         .000       
          WYEMILLS     OP     8680     138 KV    CB             .000         .000       
          STEELE       OP     8260     138 KV    CB             .000         .000       
          HILLSBRO     LD     HLSBRO   138 KV                   .000         .000       
          HILLSBRO     L      HIL-WYE  138 KV                   .000         .000       
          HILLSBRO     L      HIL-STE  138 KV                   .000         .000       
          HILLSBRO     OP     150CB    138 KV    CB             .000         .000       
 1140    L138.NewChurch-PineyGrove.13764                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          NEWCHURC     L      NEW-PIN  138 KV                   .000         .000       
          PINEYGRO     OP     131      138 KV    CB             .000         .000       
          NEWCHURC     OP     135      138 KV    CB             .000         .000       
          PINEYGRO     OP     8880     138 KV    CB             .000         .000       
          NEWCHURC     OP     130      138 KV    CB             .000         .000       
 1150    L138.NewChurch-OakHall.13765                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          OAKHALL      OP     183      138 KV    CB             .000         .000       
          NEWCHURC     L      NEW-OAK  138 KV                   .000         .000       
          NEWCHURC     OP     134      138 KV    CB             .000         .000       
          NEWCHURC     OP     133      138 KV    CB             .000         .000       
          OAKHALL      OP     188      138 KV    CB             .000         .000       
 1160    L138.NewChurch-OakHall.13763                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          NEWCHURC     OP     131      138 KV    CB             .000         .000       
          NEWCHURC     L      NEW-OAK3 138 KV                   .000         .000       
          OAKHALL      OP     185      138 KV    CB             .000         .000       
          OAKHALL      OP     187      138 KV    CB             .000         .000       
          NEWCHURC     OP     132      138 KV    CB             .000         .000       
 1170    NewChurch.CT1-2                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NEWCHURC     X      T2       138 KV                   .000         .000       
          NEWCHURC     U      CT1      13 KV                    .000         .000       
          NEWCHURC     OP     130      138 KV    CB             .000         .000       
          NEWCHURC     OP     131      138 KV    CB             .000         .000       
          NEWCHURC     U      CT2      13 KV                    .000         .000       
          NEWCHURC     X      T1       138 KV                   .000         .000       
 1180    NewChurch.CT3-4                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NEWCHURC     X      T3       138 KV                   .000         .000       
          NEWCHURC     X      T4       138 KV                   .000         .000       
          NEWCHURC     OP     134      138 KV    CB             .000         .000       
          NEWCHURC     OP     135      138 KV    CB             .000         .000       
          NEWCHURC     U      CT3      13 KV                    .000         .000       
          NEWCHURC     U      CT4      13 KV                    .000         .000       
 1190    NewChurch.CT5-7                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NEWCHURC     U      CT7      13 KV                    .000         .000       
          NEWCHURC     U      CT6      13 KV                    .000         .000       
          NEWCHURC     OP     132      138 KV    CB             .000         .000       
          NEWCHURC     OP     133      138 KV    CB             .000         .000       
          NEWCHURC     X      T7       138 KV                   .000         .000       
          NEWCHURC     X      T5       138 KV                   .000         .000       
          NEWCHURC     U      CT5      13 KV                    .000         .000       
          NEWCHURC     X      T6       138 KV                   .000         .000       
 1200    L138.Cheswold-Jones-Clayton.13770                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CLAYTON      L      CLA-JON  138 KV                   .000         .000       
          CLAYTON      OP     8280     138 KV    CB             .000         .000       
          CHESWOLD     OP     8220     138 KV    CB             .000         .000       
          CLAYTON      OP     8270     138 KV    CB             .000         .000       
          CHESWOLD     L      CHE-JON  138 KV                   .000         .000       
          JONES        OP     M-L5     138 KV    DIS            .000         .000       
          CHESWOLD     OP     8230     138 KV    CB             .000         .000       
          JONES        LD     JONES    138 KV                   .000         .000       
 1210    L138.NorthSeaford-SouthHarrington.13771           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHARRING     OP     8340     138 KV    CB             .000         .000       
          NSEAFORD     OP     8380     138 KV    CB             .000         .000       
          SHARRING     OP     8350     138 KV    CB             .000         .000       
          NSEAFORD     OP     8390     138 KV    CB             .000         .000       
          NSEAFORD     L      NSE-SHA  138 KV                   .000         .000       
 1220    L138.Felton-SouthHarrington.13709                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FELTON       OP     135      138 KV    CB             .000         .000       
          FELTON       OP     130      138 KV    CB             .000         .000       
          SHARRING     OP     8360     138 KV    CB             .000         .000       
          SHARRING     OP     8370     138 KV    CB             .000         .000       
          FELTON       L      FEL-SHA  138 KV                   .000         .000       
 1240    L138.Cheswold-Felton.13704                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          FELTON       OP     135      138 KV    CB             .000         .000      P
          FELTON       OP     133      138 KV    CB             .000         .000      P
          CHESWOLD     OP     8240     138 KV    CB             .000         .000      P
          CHESWOLD     OP     8250     138 KV    CB             .000         .000      P
          CHESWOLD     L      CHE-FEL  138 KV                   .000         .000      P
 1250    L138.Loretto-PineyGrove.13777                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          LORETTO      L      LOR-PIN  138 KV                   .000         .000      P
          PINEYGRO     OP     8880     138 KV    CB             .000         .000      P
          PINEYGRO     OP     8860     138 KV    CB             .000         .000      P
          LORETTO      OP     8470     138 KV    CB             .000         .000      P
          LORETTO      OP     8460     138 KV    CB             .000         .000      P
 1260    L138.Loretto-Vienna.13780                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LORETTO      OP     8460     138 KV    CB             .000         .000      P
          LORETTO      L      LOR-VIE  138 KV                   .000         .000      P
          LORETTO      OP     130      138 KV    CB             .000         .000      P
          VIENNA       OP     8110     138 KV    CB             .000         .000      P
          VIENNA       OP     8160     138 KV    CB             .000         .000      P
 1270    L138.KingsCreek-Loretto.13713                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          LORETTO      OP     8410     138 KV    CB             .000         .000      P
          KINGSCRK     OP     135      138 KV    CB             .000         .000      P
          KINGSCRK     OP     136      138 KV    CB             .000         .000      P
          LORETTO      OP     130      138 KV    CB             .000         .000      P
          KINGSCRK     L      KIN-LOR  138 KV                   .000         .000      P
 1280    138/69.KingsCreek.AT1                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KINGSCRK     OP     134      138 KV    CB             .000         .000       
          KINGSCRK     X      AT1      138 KV                   .000         .000       
          KINGSCRK     OP     AT1-L2   69 KV     DIS            .000         .000       
          KINGSCRK     OP     130      138 KV    CB             .000         .000       
 1290    L138.KingsCreek-Costen-Pocomoke.13714             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          POCOMOKE     OP     132 CB   138 KV    CB             .000         .000       
          COSTEN       U      COSTENSP 138 KV                   .000         .000       
          COSTEN       L      COS-KIN  138 KV                   .000         .000       
          COSTEN       LD     COSTEN   138 KV                   .000         .000       
          KINGSCRK     OP     134      138 KV    CB             .000         .000       
          KINGSCRK     OP     133      138 KV    CB             .000         .000       
          COSTEN       L      COS-POC  138 KV                   .000         .000       
 1300    L138.Edgemoor-Christiana.13805                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDGEMOOR     OP     3-4      138 KV    CB             .000         .000       
          CHR138       OP     132      138 KV    CB             .000         .000       
          EDGEMOOR     OP     3-5      138 KV    CB             .000         .000       
          CHR138       L      CHR-EDG  138 KV                   .000         .000       
          CHR138       OP     131      138 KV    CB             .000         .000       
 1310    L138.BasinRoad-ChurchmansTap-Keeney.13806/07      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BASINRD      L      BAS-CHU  138 KV                   .000         .000       
          BASINRD      OP     136      138 KV    CB             .000         .000       
          KEENEY       OP     134      138 KV    CB             .000         .000       
          CHURCTAP     LD     T4       138 KV                   .000         .000       
          KEENEY       OP     133      138 KV    CB             .000         .000       
          CHURCTAP     OP     130      138 KV    CB             .000         .000       
          CHURCTAP     OP     131      138 KV    CB             .000         .000       
          CHURCTAP     LD     T3       138 KV                   .000         .000       
          CHURCTAP     L      CHU-KEE  138 KV                   .000         .000       
          BASINRD      OP     132      138 KV    CB             .000         .000       
 1330    L138.ChapelStreet-Harmony.13821                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHAPELST     OP     132      138 KV    CB             .000         .000       
          CHAPELST     L      CHA-HAR  138 KV                   .000         .000       
          HARMONY      OP     131      138 KV    CB             .000         .000       
          CHAPELST     OP     131      138 KV    CB             .000         .000       
          HARMONY      OP     132      138 KV    CB             .000         .000       
 1340    L138.ChapelStreet-Keeney.13819/20                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHAPELST     LD     T4       138 KV                   .000         .000       
          KEENEY       L      CHA-KEE  138 KV                   .000         .000       
          KEENEY       OP     131      138 KV    CB             .000         .000       
          KEENEY       OP     130      138 KV    CB             .000         .000       
          CHAPELST     OP     130      138 KV    CB             .000         .000       
          CHAPELST     LD     T5       138 KV                   .000         .000       
          CHAPELST     OP     134      138 KV    CB             .000         .000       
 1350    L138.Harmony-Kiamensi.13828                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARMONY      OP     133      138 KV    CB             .000         .000      P
          HARMONY      L      HAR-KIA  138 KV                   .000         .000      P
          KIAMENSI     OP     137      138 KV    CB             .000         .000      P
          KIAMENSI     OP     138      138 KV    CB             .000         .000      P
          HARMONY      OP     134      138 KV    CB             .000         .000      P
 1360    L138.Hockesin-Kiamensi.13838                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOCKESIN     L      HOC-KIA  138 KV                   .000         .000       
          KIAMENSI     OP     131      138 KV    CB             .000         .000       
          KIAMENSI     OP     132      138 KV    CB             .000         .000       
          HOCKESIN     OP     130      138 KV    CB             .000         .000       
 1370    L138.Hockesin-Valley-Mer-Milltown.13835/7         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MERMAID      L      MER-MIL  138 KV                   .000         .000       
          HOCKESIN     OP     133      138 KV    CB             .000         .000       
          MILLTOWN     OP     134      138 KV    CB             .000         .000       
          MILLTOWN     OP     133      138 KV    CB             .000         .000       
          MERMAID      LD     LOADT1   138 KV                   .000         .000       
          MERMAID      L      MER-VAL  138 KV                   .000         .000       
          HOCKESIN     L      HOC-VAL  138 KV                   .000         .000       
 1380    L138.BasinRoad-Bear.13816                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BASINRD      OP     131      138 KV    CB             .000         .000       
          BASINRD      OP     136      138 KV    CB             .000         .000       
          BASINRD      L      BAS-BEA  138 KV                   .000         .000       
          BEAR DPL     OP     135      138 KV    CB             .000         .000       
          BEAR DPL     OP     133      138 KV    CB             .000         .000       
 1390    L138.BasinRoad-Kiamensi.13813                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KIAMENSI     OP     141      138 KV    CB             .000         .000       
          BASINRD      OP     132      138 KV    CB             .000         .000       
          BASINRD      L      BAS-KIA  138 KV                   .000         .000       
          KIAMENSI     OP     140      138 KV    CB             .000         .000       
          BASINRD      OP     133      138 KV    CB             .000         .000       
 1400    L138.BasinRoad-NewCastle.13815                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BASINRD      OP     131      138 KV    CB             .000         .000       
          NEWCASTL     OP     136      138 KV    CB             .000         .000       
          BASINRD      OP     135      138 KV    CB             .000         .000       
          BASINRD      L      BAS-NEW  138 KV                   .000         .000       
          NEWCASTL     OP     135      138 KV    CB             .000         .000       
 1410    L138.Bear-SunsetLake.13843                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BEAR DPL     OP     132      138 KV    CB             .000         .000       
          BEAR DPL     L      BEA-SUN  138 KV                   .000         .000       
          SUNSETLA     OP     132 CB   138 KV    CB             .000         .000       
          SUNSETLA     OP     133 CB   138 KV    CB             .000         .000       
          BEAR DPL     OP     131      138 KV    CB             .000         .000       
 1420    L138.Glasgow-MtPleasant.13801                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MTPLEASN     OP     133      138 KV    CB             .000         .000       
          GLASGOW      OP     132      138 KV    CB             .000         .000       
          MTPLEASN     OP     136      138 KV    CB             .000         .000       
          GLASGOW      OP     131      138 KV    CB             .000         .000       
          GLASGOW      L      GLA-MTP  138 KV                   .000         .000       
 1430    L138.Glasgow-Keeney.13809                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KEENEY       OP     138      138 KV    CB             .000         .000       
          GLASGOW      OP     131      138 KV    CB             .000         .000       
          KEENEY       OP     137      138 KV    CB             .000         .000       
          GLASGOW      OP     136      138 KV    CB             .000         .000       
          GLASGOW      L      GLA-KEE  138 KV                   .000         .000       
 1440    L138.Cecil-Glasgow.138-10                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CECIL        OP     133      138 KV    CB             .000         .000       
          CECIL        OP     131      138 KV    CB             .000         .000       
          GLASGOW      OP     134      138 KV    CB             .000         .000       
          GLASGOW      OP     133      138 KV    CB             .000         .000       
          CECIL        L      CEC-GLA  138 KV                   .000         .000       
 1450    L138.CedarCreek-Clayton.13832                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CEDARCRE     L      CED-CLA  138 KV                   .000         .000       
          CEDARCRE     OP     130      138 KV    CB             .000         .000       
          CLAYTON      OP     8290     138 KV    CB             .000         .000       
          CEDARCRE     OP     136      138 KV    CB             .000         .000       
          CLAYTON      OP     130      138 KV    CB             .000         .000       
 1460    L138.Church-Townsend.13833                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TOWNSEND     OP     138      138 KV    CB             .000         .000       
          CHURCH       OP     131      138 KV    CB             .000         .000       
          CHURCH       OP     8420     138 KV    CB             .000         .000       
          TOWNSEND     OP     131      138 KV    CB             .000         .000       
          CHURCH       L      CHU-TOW  138 KV                   .000         .000       
 1470    138/69.Loretto.AT1&2                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LORETTO      OP     7430     69 KV     CB             .000         .000       
          LORETTO      X      AT2      138 KV                   .000         .000       
          LORETTO      X      AT1      138 KV                   .000         .000       
          LORETTO      OP     7440     69 KV     CB             .000         .000       
          LORETTO      OP     8470     138 KV    CB             .000         .000       
          LORETTO      OP     8410     138 KV    CB             .000         .000       
 1480    138/69.Cheswold.AT1 + L69.Cheswold-Kent.6768      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KENT         OP     7870     69 KV     CB             .000         .000       
          CHESWOLD     L      CHE-KEN  69 KV                    .000         .000       
          CHESWOLD     OP     130 CB   138 KV    CB             .000         .000       
          CHESWOLD     OP     8250     138 KV    CB             .000         .000       
          KENT         OP     7890     69 KV     CB             .000         .000       
          CHESWOLD     X      AT1      138 KV                   .000         .000       
 1490    138/69.Easton.AT1 + L138.Steele-Easton.13712      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EASTON       OP     7410     69 KV     CB             .000         .000      P
          EASTON       X      AT-1     138 KV                   .000         .000      P
          EASTON       OP     165      138 KV    CB             .000         .000      P
          EASTON       OP     7420     69 KV     CB             .000         .000      P
          EASTON       L      EAS-STE  138 KV                   .000         .000      P
 1500    138/69.Edgemoor.AT1&AT2                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDGEMOOR     OP     SWHATH2  138 KV    DIS            .000         .000      P
          EDGEMOOR     OP     SWLATL2  69 KV     DIS            .000         .000      P
          EDGEMOOR     OP     SWHATH1  138 KV    DIS            .000         .000      P
          EDGEMOOR     OP     SWLATL1  69 KV     DIS            .000         .000      P
          EDGEMOOR     OP     2-4      69 KV     CB             .000         .000      P
          EDGEMOOR     X      AT1      138 KV                   .000         .000      P
          EDGEMOOR     X      AT2      138 KV                   .000         .000      P
          EDGEMOOR     OP     2-5      69 KV     CB             .000         .000      P
          EDGEMOOR     OP     3-3      138 KV    CB             .000         .000      P
 1510    138/69.NorthSeaford.AT1                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NSEAFORD     OP     8380     138 KV    CB             .000         .000      P
          NSEAFORD     X      AT-1     138 KV                   .000         .000      P
          NSEAFORD     OP     7340     69 KV     CB             .000         .000      P
          NSEAFORD     OP     7350     69 KV     CB             .000         .000      P
          NSEAFORD     OP     8370     138 KV    CB             .000         .000      P
 1520    138/69.NorthSeaford.AT2                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NSEAFORD     OP     131      138 KV    CB             .000         .000      P
          NSEAFORD     OP     7320     69 KV     CB             .000         .000      P
          NSEAFORD     X      AT-2     138 KV                   .000         .000      P
          NSEAFORD     OP     60       69 KV     CB             .000         .000      P
          NSEAFORD     OP     8390     138 KV    CB             .000         .000      P
 1530    138/69.Nelson.AT1 + Nelson.69.Cap1                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NELSON       OP     74       69 KV     CB             .000         .000      P
          NELSON       OP     152      138 KV    CB             .000         .000      P
          NELSON       OP     77       69 KV     CB             .000         .000      P
          NELSON       OP     153      138 KV    CB             .000         .000      P
          NELSON       X      AT1      138 KV                   .000         .000      P
          NELSON       OP     80       69 KV     CB             .000         .000      P
          NELSON       CP     CAP1     69 KV                    .000         .000      P
 1540    138/69.OakHall.AT1                                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OAKHALL      OP     181      138 KV    CB             .000         .000      P
          OAKHALL      OP     7240     69 KV     CB             .000         .000      P
          OAKHALL      X      AT1      138 KV                   .000         .000      P
          OAKHALL      OP     7220     69 KV     CB             .000         .000      P
          OAKHALL      OP     186      138 KV    CB             .000         .000      P
 1550    138/69.OakHall.AT2                                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OAKHALL      X      AT2      138 KV                   .000         .000       
          OAKHALL      OP     7290     69 KV     CB             .000         .000       
          OAKHALL      OP     7270     69 KV     CB             .000         .000       
          OAKHALL      OP     184      138 KV    CB             .000         .000       
          OAKHALL      OP     185      138 KV    CB             .000         .000       
 1560    138/69.PineyGrove.AT1                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PINEYGRO     OP     130      138 KV    CB             .000         .000      P
          PINEYGRO     OP     7920     69 KV     CB             .000         .000      P
          PINEYGRO     X      AT1      138 KV                   .000         .000      P
          PINEYGRO     OP     7960     69 KV     CB             .000         .000      P
          PINEYGRO     OP     131      138 KV    CB             .000         .000      P
 1570    138/69.SouthHarrington.AT1                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHARRING     X      AT1      138 KV                   .000         .000       
          SHARRING     CL     8370     138 KV    CB             .000         .000       
          SHARRING     OP     7270     69 KV     CB             .000         .000       
          SHARRING     OP     7260     69 KV     CB             .000         .000       
          SHARRING     OP     8340     138 KV    CB             .000         .000       
 1580    138/69.Vienna.AT1                                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          VIENNA       X      AT1      138 KV                   .000         .000      P
          VIENNA       OP     7710     69 KV     CB             .000         .000      P
          VIENNA       OP     8150     138 KV    CB             .000         .000      P
          VIENNA       OP     8120     138 KV    CB             .000         .000      P
 1590    138/69.Vienna.AT2                                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          VIENNA       OP     7720     69 KV     CB             .000         .000       
          VIENNA       X      AT2      138 KV                   .000         .000       
          VIENNA       OP     8170     138 KV    CB             .000         .000       
          VIENNA       OP     8160     138 KV    CB             .000         .000       
 1600    138/69.WyeMills.AT1                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WYEMILLS     OP     131 CB   138 KV    CB             .000         .000      P
          WYEMILLS     OP     7550     69 KV     CB             .000         .000      P
          WYEMILLS     X      AT-1     138 KV                   .000         .000      P
          WYEMILLS     OP     132 CB   138 KV    CB             .000         .000      P
          WYEMILLS     OP     7560     69 KV     CB             .000         .000      P
 1610    L69.Fruitland-Pemberton-NorthSalisbury.6701       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NSALISBU     OP     6718_BT  69 KV     DIS            .000         .000       
          FRUITLAN     OP     7550     69 KV     CB             .000         .000       
          PEMBERTO     OP     60       69 KV     CB             .000         .000       
          NSALISBU     OP     63       69 KV     CB             .000         .000       
          FRUITLAN     L      FRT-PEM  69 KV                    .000         .000       
          PEMBERTO     LD     T-1      69 KV                    .000         .000       
          NSALISBU     L      NSA-PEM  69 KV                    .000         .000       
 1620    L69.Todd-ViennaLocal-Vienna.6702                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TODD         OP     7350     69 KV     CB             .000         .000       
          VIENNA       OP     1200     69 KV     CB             .000         .000       
          VIENNALO     OP     6702-L2  69 KV     DIS            .000         .000       
          VIENNA       L      VIE-VNL2 69 KV                    .000         .000       
          VIENNA       OP     500      69 KV     CB             .000         .000       
          TODD         OP     7370     69 KV     CB             .000         .000       
          VIENNALO     CL     6709-57  69 KV     DIS            .000         .000       
          TODD         L      TOD-VNL  69 KV                    .000         .000       
 1630    L69.Loretto-Princess (LOAD TAP)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LORETTO      LD     PRNCSS   69 KV                    .000         .000       
          LORETTO      OP     7440     69 KV     CB             .000         .000       
          LORETTO      OP     7450     69 KV     CB             .000         .000       
 1640    L69.Church-NewMeredith-Kent.6704                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHURCH       OP     7290     69 KV     CB             .000         .000       
          KENT         OP     7870     69 KV     CB             .000         .000       
          NEWMERED     LD     N-MERD   69 KV                    .000         .000       
          KENT         L      KEN-NME  69 KV                    .000         .000       
          KENT         OP     7860     69 KV     CB             .000         .000       
          CHURCH       OP     7220     69 KV     CB             .000         .000       
          CHURCH       L      CHU-NME  69 KV                    .000         .000       
 1650    L69.Laurel-Sharptown-Vienna.6705                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          VIENNA       OP     288      69 KV     CB             .000         .000       
          LAURELDP     L      LAU-SHA  69 KV                    .000         .000       
          LAURELDP     OP     6705-280 69 KV     DIS            .000         .000       
          SHARP        L      SHA-VIE  69 KV                    .000         .000       
          SHARP        LD     SHARP    69 KV                    .000         .000       
 1660    L69.Laurel-Short-Nelson.6706                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NELSON       L      NEL-SHO  69 KV                    .000         .000      P
          SHORT        LD     SHORT    69 KV                    .000         .000      P
          LAURELDP     L      LAU-SHO  69 KV                    .000         .000      P
          NELSON       OP     76       69 KV     CB             .000         .000      P
          LAURELDP     OP     6706-350 69 KV     DIS            .000         .000      P
          NELSON       OP     77       69 KV     CB             .000         .000      P
 1670    L69.Easton-EastonTap-Muni-Longwood-WyeMills.6707  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LONGWOOD     L      LON-WYE  69 KV                    .000         .000      P
          WYEMILLS     OP     7570     69 KV     CB             .000         .000      P
          EASTONTP     OP     SW_TAP1  69 KV     CB             .000         .000      P
          EASTONTP     L      EAT-LON  69 KV                    .000         .000      P
          EASTON       L      EAS-EAT  69 KV                    .000         .000      P
          EMUNI        L      EAT-EMU  69 KV                    .000         .000      P
          EASTON       OP     61       69 KV     CB             .000         .000      P
          EMUNI        OP     3610     69 KV     DIS            .000         .000      P
          LONGWOOD     LD     LONGWD   69 KV                    .000         .000      P
          WYEMILLS     OP     7510     69 KV     CB             .000         .000      P
          EASTON       OP     7450     69 KV     CB             .000         .000      P
 1680    L69.NorthSalisbury-Rockawlkn-H-Mardela-Vienna.6708Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROCKWLKN     L      NSA-ROCK 69 KV                    .000         .000      P
          HEBRON       L      HEB-ROC  69 KV                    .000         .000      P
          HEBRON       LD     HEBRON   69 KV                    .000         .000      P
          NSALISBU     OP     64       69 KV     CB             .000         .000      P
          MARDELA      L      MAR-VIE  69 KV                    .000         .000      P
          VIENNA       OP     488      69 KV     CB             .000         .000      P
          HEBRON       L      HEB-MAR  69 KV                    .000         .000      P
          MARDELA      LD     MARREA   69 KV                    .000         .000      P
          ROCKWLKN     LD     LOAD1    69 KV                    .000         .000      P
 1690    L69.Church-IBCornrs-Pric-Centreville-WyeMills.6710Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PRICE        L      CNT-PRI  69 KV                    .000         .000      P
          CHURCH       OP     7250     69 KV     CB             .000         .000      P
          WYEMILLS     OP     7540     69 KV     CB             .000         .000      P
          CHURCH       OP     7240     69 KV     CB             .000         .000      P
          CENTREVL     L      CNT-WYE  69 KV                    .000         .000      P
          CENTREVL     LD     448      69 KV                    .000         .000      P
          IBCORN       LD     IBCORN   69 KV                    .000         .000      P
          PRICE        LD     PRICE T1 69 KV                    .000         .000      P
          CENTREVL     LD     449      69 KV                    .000         .000      P
          WYEMILLS     OP     7550     69 KV     CB             .000         .000      P
          IBCORN       L      IBC-PRI  69 KV                    .000         .000      P
          CHURCH       L      CHU-IBC  69 KV                    .000         .000      P
 1700    L69.Fruitland-Loretto.6711                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LORETTO      OP     7450     69 KV     CB             .000         .000      P
          LORETTO      OP     7430     69 KV     CB             .000         .000      P
          FRUITLAN     L      FRT-LOR  69 KV                    .000         .000      P
          FRUITLAN     OP     7500     69 KV     CB             .000         .000      P
 1710    L69.Kenney-Stockton-Signpost-Wattsville.6712      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SIGNPOST     L      SGP-WAT  69 KV                    .000         .000      P
          SIGNPOST     L      SGP-STO  69 KV                    .000         .000      P
          KENNEY       OP     62       69 KV     CB             .000         .000      P
          WATTSVIL     OP     61       69 KV     CB             .000         .000      P
          SIGNPOST     LD     LOAD     69 KV                    .000         .000      P
          WATTSVIL     OP     60       69 KV     CB             .000         .000      P
          KENNEY       L      KEN-STO  69 KV                    .000         .000      P
          STOCKTON     LD     STOCTN   69 KV                    .000         .000      P
          KENNEY       OP     6712-L4  69 KV     DIS            .000         .000      P
          KENNEY       OP     63       69 KV     CB             .000         .000      P
 1720    L69.Easton-TrappeTap-Talbt-Tanyd-Preston-Todd.6716Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TRAPPETP     OP     6716-L11 69 KV     DIS            .000         .000      P
          TODD         OP     7330     69 KV     CB             .000         .000      P
          TALBOT       LD     TALBOT   69 KV                    .000         .000      P
          TRAPPETP     S      DUMTRAP  69 KV                    .000         .000      P
          EASTON       OP     7480     69 KV     CB             .000         .000      P
          PRESTON      LD     PRSTON   69 KV                    .000         .000      P
          EASTON       L      EAS-TRA  69 KV                    .000         .000      P
          TALBOT       L      TAL-TAN  69 KV                    .000         .000      P
          EASTON       CP     EASTON   69 KV                    .000         .000      P
          EASTON       OP     7460     69 KV     CB             .000         .000      P
          PRESTON      L      PRE-TOD  69 KV                    .000         .000      P
          TANYARD      LD     TANYRD   69 KV                    .000         .000      P
          PRESTON      L      PRE-TAN  69 KV                    .000         .000      P
          EASTON       OP     7410     69 KV     CB             .000         .000      P
          TALBOT       L      TAL-TRA  69 KV                    .000         .000      P
          TODD         OP     7380     69 KV     CB             .000         .000      P
          TRAPPETP     LD     TRAPPE   69 KV                    .000         .000      P
 1730    L69.OakHall-Wattsville.6717 + 69/25.Wattsville.T2 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OAKHALL      OP     3239     25 KV     DIS            .000         .000      P
          OAKHALL      L      OAK-WAT  69 KV                    .000         .000      P
          WATTSVIL     OP     7650     69 KV     CB             .000         .000      P
          WATTSVIL     OP     7630     69 KV     CB             .000         .000      P
          OAKHALL      X      T2       69 KV                    .000         .000      P
          OAKHALL      OP     7270     69 KV     CB             .000         .000      P
          OAKHALL      OP     7240     69 KV     CB             .000         .000      P
 1740    L69.Tasley-BelleHaven-Kellam.6703                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KELLAM       OP     6703-L5  69 KV     DIS            .000         .000       
          KELLAM       OP     74       69 KV     CB             .000         .000       
          KELLAM       OP     75       69 KV     CB             .000         .000       
          BELLEHAV     L      BEL-TAS  69 KV                    .000         .000       
          BELLEHAV     LD     LOAD     12 KV                    .000         .000       
          TASLEY       OP     7470     69 KV     CB             .000         .000       
          TASLEY       OP     7480     69 KV     CB             .000         .000       
          BELLEHAV     X      T1       69 KV                    .000         .000       
          BELLEHAV     L      BEL-KEL  69 KV                    .000         .000       
          BELLEHAV     CP     SMES CAP 69 KV                    .000         .000       
          BELLEHAV     U      D-SMES   12 KV                    .000         .000       
 1750    L69.KingsCreek-Westover-Kingston-Crisfield.6725   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CRISFIE      CP     CAP2     69 KV                    .000         .000      P
          CRISFIE      X      T2       12 KV                    .000         .000      P
          CRISFIE      CP     CAP1     69 KV                    .000         .000      P
          CRISFIE      OP     7130     69 KV     CB             .000         .000      P
          CRISFIE      X      T1       69 KV                    .000         .000      P
          CRISFIE      U      G2       4 KV                     .000         .000      P
          CRISFIE      OP     61       69 KV     CB             .000         .000      P
          KINGSCRK     L      KIN-WOR  69 KV                    .000         .000      P
          KINGSTON     L      KST-WOR  69 KV                    .000         .000      P
          CRISFIE      OP     62       69 KV     CB             .000         .000      P
          CRISFIE      U      G3       4 KV                     .000         .000      P
          WOVERDPL     LD     WSTOVR   69 KV                    .000         .000      P
          KINGSTON     LD     KNGSTN   69 KV                    .000         .000      P
          CRISFIE      X      T3       69 KV                    .000         .000      P
          CRISFIE      LD     LOAD25   25 KV                    .000         .000      P
          CRISFIE      L      CRI-KST  69 KV                    .000         .000      P
          CRISFIE      LD     LOAD12   12 KV                    .000         .000      P
          CRISFIE      U      G1       4 KV                     .000         .000      P
          KINGSCRK     OP     62CB     69 KV     CB             .000         .000      P
          KINGSCRK     OP     63CB     69 KV     CB             .000         .000      P
          CRISFIE      U      G4       4 KV                     .000         .000      P
 1760    L69.MountHermon-NorthSalisbury.6726               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MTHERMON     OP     7590     69 KV     CB             .000         .000       
          MTHERMON     L      MTH-NSA  69 KV                    .000         .000       
          NSALISBU     OP     61       69 KV     CB             .000         .000       
 1770    L69.MountHermon-PineyGrove.6728                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MTHERMON     OP     7570     69 KV     CB             .000         .000      P
          PINEYGRO     OP     7980     69 KV     CB             .000         .000      P
          PINEYGRO     CP     CAP1     69 KV                    .000         .000      P
          MTHERMON     L      MTH-PIN  69 KV                    .000         .000      P
          PINEYGRO     OP     7910     69 KV     CB             .000         .000      P
          PINEYGRO     OP     7960     69 KV     CB             .000         .000      P
 1780    L69.Kenney-MtOlive-PineyGrove.6729                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KENNEY       OP     6729-L4  69 KV     DIS            .000         .000      P
          KENNEY       L      KEN-MTO  69 KV                    .000         .000      P
          MTOLIVE      U      WRCETRLF 69 KV                    .000         .000      P
          PINEYGRO     OP     7910     69 KV     CB             .000         .000      P
          KENNEY       OP     60       69 KV     CB             .000         .000      P
          KENNEY       OP     61       69 KV     CB             .000         .000      P
          MTOLIVE      LD     MT-OLV   69 KV                    .000         .000      P
          MTOLIVE      L      MTO-PIN  69 KV                    .000         .000      P
          PINEYGRO     OP     7920     69 KV     CB             .000         .000      P
 1790    L69.DupontSeaford-Laurel.6736                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LAURELDP     OP     62       69 KV     CB             .000         .000       
          DUPSEAFD     OP     70       69 KV     CB             .000         .000       
          DUPSEAFD     L      DUP-LAU  69 KV                    .000         .000       
 1800    L69.Bridgeville-Taylor-NorthSeaford.6737          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NSEAFORD     OP     7330     69 KV     CB             .000         .000       
          TAYLOR       LD     TAYLOR   69 KV                    .000         .000       
          NSEAFORD     OP     7340     69 KV     CB             .000         .000       
          BRIDGEVI     L      BRD-TAT  69 KV                    .000         .000       
          BRIDGEVI     OP     CB62     69 KV     CB             .000         .000       
          NSEAFORD     L      NSE-TAT  69 KV                    .000         .000       
          TAYLOR       OP     TAYLORSW 69 KV     DIS            .000         .000       
 1810    L69.Bridgeville-Kratz-SouthHarrington.6738        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRIDGEVI     L      BRI-KRAT 69 KV                    .000         .000       
          SHARRING     OP     65       69 KV     CB             .000         .000       
          SHARRING     OP     7270     69 KV     CB             .000         .000       
          KRATZ        L      KRA-SHAR 69 KV                    .000         .000       
          KRATZ        LD     KRATZ    69 KV                    .000         .000       
          BRIDGEVI     OP     CB60     69 KV     CB             .000         .000       
          SHARRING     OP     7280     69 KV     CB             .000         .000       
 1820    L69.Harrington-SouthHarrington.6739               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARRTN       L      HAR-SHA  69 KV                    .000         .000       
          HARRTN       OP     7210     69 KV     CB             .000         .000       
          SHARRING     OP     7260     69 KV     CB             .000         .000       
          SHARRING     OP     7280     69 KV     CB             .000         .000       
          HARRTN       OP     60       69 KV     CB             .000         .000       
 1830    L69.Nelson-Edgewood-NorthSalisbury.6743           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NSALISBU     OP     62       69 KV     CB             .000         .000       
          NELSON       OP     76       69 KV     CB             .000         .000       
          NELSON       OP     74       69 KV     CB             .000         .000       
          EDGEWDPL     L      EDG-NSA  69 KV                    .000         .000       
          EDGEWDPL     L      EDG-NEL  69 KV                    .000         .000       
          EDGEWDPL     LD     EDGEWD   69 KV                    .000         .000       
 1840    L69.Kellam-WeirwoodTap-Eastville-Bayview.6750     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BAYVIEW      X      T1       69 KV                    .000         .000       
          EASTVILL     L      EAS-KEN  69 KV                    .000         .000       
          BAYVIEW      L      BAY-EAV  69 KV                    .000         .000       
          BAYVIEW      OP     3110     25 KV     CB             .000         .000       
          BAYVIEW      X      T2       25 KV                    .000         .000       
          BAYVIEW      U      G5       4 KV                     .000         .000       
          BAYVIEW      U      WINDFARM 25 KV                    .000         .000       
          BAYVIEW      CP     CAP1     25 KV                    .000         .000       
          BAYVIEW      OP     PCB 60   69 KV     CB             .000         .000       
          BAYVIEW      U      G4       4 KV                     .000         .000       
          BAYVIEW      CP     CAP2     69 KV                    .000         .000       
          EASTVILL     LD     EASTVL   69 KV                    .000         .000       
          KENDLGRV     L      KEN-WEI  69 KV                    .000         .000       
          BAYVIEW      LD     LOAD62   25 KV                    .000         .000       
          BAYVIEW      U      G3       4 KV                     .000         .000       
          KELLAM       OP     73       69 KV     CB             .000         .000       
          BAYVIEW      OP     70       69 KV     CB             .000         .000       
          KELLAM       L      KEL-WEI  69 KV                    .000         .000       
          KELLAM       OP     72       69 KV     CB             .000         .000       
          BAYVIEW      U      G2       4 KV                     .000         .000       
          BAYVIEW      U      G1       4 KV                     .000         .000       
          BAYVIEW      LD     LOAD40   25 KV                    .000         .000       
          BAYVIEW      U      G6       4 KV                     .000         .000       
          WEIRWDTP     LD     LOAD1    69 KV                    .000         .000       
          BAYVIEW      LD     LOAD19   25 KV                    .000         .000       
 1850    25/4.Bayview.T2 + Bayview.CT.1-6                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BAYVIEW      U      G4       4 KV                     .000         .000       
          BAYVIEW      U      G3       4 KV                     .000         .000       
          BAYVIEW      U      G5       4 KV                     .000         .000       
          BAYVIEW      X      T2       25 KV                    .000         .000       
          BAYVIEW      U      G6       4 KV                     .000         .000       
          BAYVIEW      U      G2       4 KV                     .000         .000       
          BAYVIEW      OP     3110     25 KV     CB             .000         .000       
          BAYVIEW      U      G1       4 KV                     .000         .000       
 1860    L69.DupontSeaford-PineStreet-NorthSeaford.6752    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NSEAFORD     OP     7330     69 KV     CB             .000         .000       
          PINE ST      LD     SEACTY   69 KV                    .000         .000       
          DUPSEAFD     OP     72       69 KV     CB             .000         .000       
          DUPSEAFD     L      DUP-PIN  69 KV                    .000         .000       
          NSEAFORD     L      NSE-PIN  69 KV                    .000         .000       
          NSEAFORD     OP     60       69 KV     CB             .000         .000       
 1870    L69.Harrington-Wells-Vaughn-Kent.6784             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          VAUGHN       LD     VAUGHN   69 KV                    .000         .000       
          HARRTN       OP     7230     69 KV     CB             .000         .000       
          VAUGHN       L      VAU-WEL  69 KV                    .000         .000       
          KENT         OP     7830     69 KV     CB             .000         .000       
          WELLS        LD     WELLSLD  69 KV                    .000         .000       
          VAUGHN       U      CENTRALF 69 KV                    .000         .000       
          HARRTN       L      HAR-WEL  69 KV                    .000         .000       
          KENT         OP     7840     69 KV     CB             .000         .000       
          HARRTN       OP     7240     69 KV     CB             .000         .000       
          KENT         L      KEN-VAU  69 KV                    .000         .000       
 1880    L138.OakHall-Pocomoke.13787                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          OAKHALL      L      OAK-POC  138 KV                   .000         .000       
          OAKHALL      OP     183      138 KV    CB             .000         .000       
          POCOMOKE     OP     130 CB   138 KV    CB             .000         .000       
          OAKHALL      OP     181      138 KV    CB             .000         .000       
 1890    L69.OakHall-Perdue-Tasley.6778                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TASLEY       OP     7450     69 KV     CB             .000         .000       
          PERDUE       L      PER-TAS  69 KV                    .000         .000       
          OAKHALL      OP     7260     69 KV     CB             .000         .000       
          TASLEY       OP     7460     69 KV     CB             .000         .000       
          PERDUE       LD     LOAD1    69 KV                    .000         .000       
          OAKHALL      OP     7290     69 KV     CB             .000         .000       
          PERDUE       L      OAK-PER  69 KV                    .000         .000       
 1900    L69.OakHall-Hallwood-GreenBush-Tasley.6790        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OAKHALL      L      HAL-OAK  69 KV                    .000         .000       
          GREENBUS     L      GRN-HAL  69 KV                    .000         .000       
          GREENBUS     OP     7510     69 KV     CB             .000         .000       
          OAKHALL      OP     7210     69 KV     CB             .000         .000       
          GREENBUS     LD     GRNBSH   69 KV                    .000         .000       
          TASLEY       OP     7440     69 KV     CB             .000         .000       
          TASLEY       L      GRN-TAS  69 KV                    .000         .000       
          OAKHALL      OP     7220     69 KV     CB             .000         .000       
          TASLEY       OP     7400     69 KV     CB             .000         .000       
          HALLWOOD     LD     HALLWD   69 KV                    .000         .000       
 1910    230/138.PineyGrove.AT20+L230.PinyGrve-IndinR.23002Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          PINEYGRO     OP     8870     138 KV    CB             .000         .000       
          PINEYGRO     OP     8860     138 KV    CB             .000         .000       
          PINEYGRO     OP     9530     230 KV    CB             .000         .000       
          PINEYGRO     X      AT20     230 KV                   .000         .000       
 1920    L230.IndianRvr-PineyGrve.23002+230/138.PinyGr.AT20Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          INDIANRI     L      IND-PIN  230 KV                   .000         .000       
          INDIANRI     OP     234      230 KV    CB             .000         .000       
          PINEYGRO     OP     9530     230 KV    CB             .000         .000       
          INDIANRI     OP     235      230 KV    CB             .000         .000       
 1930    138/69.Church.AT1                                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHURCH       OP     60       69 KV     CB             .000         .000      P
          CHURCH       X      AT1      138 KV                   .000         .000      P
          CHURCH       OP     8430     138 KV    CB             .000         .000      P
          CHURCH       OP     132      138 KV    CB             .000         .000      P
          CHURCH       OP     7260     69 KV     CB             .000         .000      P
 1940    230/138.Steele.AT20                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STEELE       OP     250      230 KV    CB             .000         .000       
          STEELE       OP     8250     138 KV    CB             .000         .000       
          STEELE       X      AT20     230 KV                   .000         .000       
          STEELE       OP     9210     230 KV    CB             .000         .000       
          STEELE       OP     8290     138 KV    CB             .000         .000       
 1950    230/138.Steele.AT21                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STEELE       OP     251      230 KV    CB             .000         .000      P
          STEELE       OP     8270     138 KV    CB             .000         .000      P
          STEELE       X      AT21     230 KV                   .000         .000      P
          STEELE       OP     252      230 KV    CB             .000         .000      P
          STEELE       OP     130      138 KV    CB             .000         .000      P
 1960    Steele.138.Cap.1-2                                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STEELE       OP     8270     138 KV    CB             .000         .000      P
          STEELE       CP     CAP2     138 KV                   .000         .000      P
          STEELE       OP     8280     138 KV    CB             .000         .000      P
          STEELE       CP     CAP1     138 KV                   .000         .000      P
 1970    L138.Steele-Easton.13712 + 138/69.Easton.AT1      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STEELE       OP     130      138 KV    CB             .000         .000      P
          STEELE       OP     8260     138 KV    CB             .000         .000      P
          EASTON       X      AT-1     138 KV                   .000         .000      P
          EASTON       L      EAS-STE  138 KV                   .000         .000      P
          EASTON       OP     165      138 KV    CB             .000         .000      P
 1980    138/69.Cromby.T3                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROMBY       OP     270 CB   138 KV    CB             .000         .000      P
          CROMBY       OP     250 CB   69 KV     CB             .000         .000      P
          CROMBY       X      CROM3TR  138 KV                   .000         .000      P
 1990    138/69.Cromby.T4                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROMBY       X      CROM4TR  138 KV                   .000         .000      P
          CROMBY       OP     370 CB   138 KV    CB             .000         .000      P
          CROMBY       OP     350 CB   69 KV     CB             .000         .000      P
 2020    500/138.Wescosville.T3                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          WESCOSVI     OP     TRAN3500 500 KV    CB             .000         .000      P
          WESCOSVI     X      3        500 KV                   .000         .000      P
          WESCOSVI     OP     TRAN3138 138 KV    CB             .000         .000      P
 2040    500/230.EastWindsor.T1                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EWINDSOR     OP     B3       500 KV    CB             .000         .000      P
          EWINDSOR     OP     B13      500 KV    CB             .000         .000      P
          EWINDSOR     X      T-1      500 KV                   .000         .000      P
          EWINDSOR     OP     B40      230 KV    CB             .000         .000      P
          EWINDSOR     OP     G2       230 KV    CB             .000         .000      P
 2050    500/230.EastWindsor.T2                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EWINDSOR     OP     B3       500 KV    CB             .000         .000      P
          EWINDSOR     OP     G2       230 KV    CB             .000         .000      P
          EWINDSOR     OP     2F       230 KV    CB             .000         .000      P
          EWINDSOR     OP     B10      500 KV    CB             .000         .000      P
          EWINDSOR     X      BK 2TR   500 KV                   .000         .000      P
 2060    500/230.Hunterstown.T1                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          HUNTERST     OP     B1       230 KV    CB             .000         .000      P
          HUNTERST     OP     105392   230 KV    CB             .000         .000      P
          HUNTERST     OP     B192     500 KV    CB             .000         .000      P
          HUNTERST     X      1 BANK   500 KV                   .000         .000      P
 2070    500/230.Brighton.T1                               Y Y Y S Y Y N N     YNNNNNNNNNNYNNNNNNNNNNNYN YNNNNNNNNNNYNNNNNNNNNNNYN
          BRIGHTON     OP     1DB      230 KV    CB             .000         .000      P
          BRIGHTON     X      NO.1TR   500 KV                   .000         .000      P
          BRIGHTON     OP     6BB      500 KV    CB             .000         .000      P
          BRIGHTON     OP     6CB      500 KV    CB             .000         .000      P
          BRIGHTON     OP     3DB      230 KV    CB             .000         .000      P
 2080    500/138.Cabot.T1&T3 (Sctnlz F)                    Y Y Y S Y Y N N     NNNNNNNNNNYNNNNNNNNNYYNNN NNNNNNNNNNYNNNNNNNNNYYNNN
          CABOT        OP     CB 01    500 KV    CB             .000         .000      P
          CABOT        OP     C19      138 KV    CB             .000         .000      P
          CABOT        OP     CB 05    500 KV    CB             .000         .000      P
          CABOT        OP     C11      138 KV    CB             .000         .000      P
          CABOT        X      TRAN  3  500 KV                   .000         .000      P
          CABOT        X      TRAN  1  500 KV                   .000         .000      P
 2100    BrandonShores.U1                                  Y Y Y S Y Y N N     YNNNNNNNNNNYNNNNNNNNNNNYN YNNNNNNNNNNYNNNNNNNNNNNYN
          BRANDONS     OP     23432391 230 KV    CB             .000         .000      P
          BRANDONS     X      1GEN XF  230 KV                   .000         .000      P
          BRANDONS     U      GEN 01   24 KV                    .000         .000      P
          BRANDONS     OP     2391CB   230 KV    CB             .000         .000      P
 2110    BrandonShores.U2                                  Y Y Y S Y Y N N     YNNNNNNNNNNYNNNNNNNNNNNYN YNNNNNNNNNNYNNNNNNNNNNNYN
          BRANDONS     U      GEN 02   24 KV                    .000         .000       
          BRANDONS     OP     2392CB   230 KV    CB             .000         .000       
          BRANDONS     OP     23422392 230 KV    CB             .000         .000       
          BRANDONS     X      2GEN XF  230 KV                   .000         .000       
 2120    BrunnerIsland.U3                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRUNNERI     X      3        230 KV                   .000         .000       
          BRUNNERI     OP     GEN_3-W  230 KV    CB             .000         .000       
          BRUNNERI     U      UNIT03   24 KV                    .000         .000       
          BRUNNERI     OP     GEN_3-E  230 KV    CB             .000         .000       
 2130    CalvertCliffs.U1(for TLC)                         Y Y Y S Y Y N N     NNNNNYYNNNNYNNNNYNNNNNNNN NNNNNYYNNNNYNNNNYNNNNNNNN
          CALVERTC     U      GEN 01   25 KV                    .000         .000       
          CALVERTC     OP     50511GEN 500 KV    CB             .000         .000       
          CALVERTC     X      1GEN XF  500 KV                   .000         .000       
          CALVERTC     OP     1GEN     500 KV    CB             .000         .000       
 2140    CalvertCliffs.U2(for TLC)                         Y Y Y S Y Y N N     NNNNNYYNNNNYNNNNYNNNNNNNN NNNNNYYNNNNYNNNNYNNNNNNNN
          CALVERTC     OP     2GEN_72  500 KV    CB             .000         .000       
          CALVERTC     OP     2GEN     500 KV    CB             .000         .000       
          CALVERTC     U      GEN 02   22 KV                    .000         .000       
          CALVERTC     X      2GEN XF  500 KV                   .000         .000       
 2150    DBL:CalvertCliffs.U1 & CalvertCliffs.U2           Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNYNNNNNNN NNNNNNNNNNNNNNNNNYNNNNNNN
          CALVERTC     U      GEN 01   25 KV                    .000         .000       
          CALVERTC     X      2GEN XF  500 KV                   .000         .000       
          CALVERTC     OP     2GEN     500 KV    CB             .000         .000       
          CALVERTC     U      GEN 02   22 KV                    .000         .000       
          CALVERTC     OP     1GENBKR  25 KV     CB             .000         .000       
          CALVERTC     OP     50511GEN 500 KV    CB             .000         .000       
          CALVERTC     OP     2GEN_72  500 KV    CB             .000         .000       
          CALVERTC     OP     1GEN     500 KV    CB             .000         .000       
 2160    ChalkPoint.U3                                     Y Y Y S Y Y N N     YNNNNNNNNNNYNNNNNNNNNNNYN YNNNNNNNNNNYNNNNNNNNNNNYN
          CHALKPT      OP     6BB      230 KV    CB             .000         .000      P
          CHALKPT      OP     6CB      230 KV    CB             .000         .000      P
          CHALKPT      X      STAE-U3  230 KV                   .000         .000      P
          CHALKPT      U      CHLKG3   24 KV                    .000         .000      P
 2170    ChalkPoint.U4                                     Y Y Y S Y Y N N     YNNNNNNNNNNYNNNNNNNNNNNYN YNNNNNNNNNNYNNNNNNNNNNNYN
          CHALKPT      OP     7CB      230 KV    CB             .000         .000      P
          CHALKPT      OP     7BB      230 KV    CB             .000         .000      P
          CHALKPT      X      STAE-U4  230 KV                   .000         .000      P
          CHALKPT      U      CHLKG4   24 KV                    .000         .000      P
 2180    Conemaugh.U1                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONEMAUG     U      UNIT 1   22 KV                    .000         .000      P
          CONEMAUG     X      BK 1 50  500 KV                   .000         .000      P
          CONEMAUG     OP     B7       500 KV    CB             .000         .000      P
          CONEMAUG     OP     B6       500 KV    CB             .000         .000      P
 2190    Conemaugh.U2                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONEMAUG     U      UNIT02   22 KV                    .000         .000      P
          CONEMAUG     OP     B2       500 KV    CB             .000         .000      P
          CONEMAUG     OP     B1       500 KV    CB             .000         .000      P
          CONEMAUG     X      BK 2 50  500 KV                   .000         .000      P
 2200    Eddystone.U3                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDDYSTON     X      EDDY 3   230 KV                   .000         .000      P
          EDDYSTON     OP     35 CB    230 KV    CB             .000         .000      P
          EDDYSTON     U      UNIT03   20 KV                    .000         .000      P
 2210    Eddystone.U4                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDDYSTON     OP     45 CB    230 KV    CB             .000         .000      P
          EDDYSTON     U      UNIT04   20 KV                    .000         .000      P
          EDDYSTON     X      EDDY 4   230 KV                   .000         .000      P
 2220    HomerCity.U1                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOMERCIT     OP     205      230 KV    CB             .000         .000      P
          HOMERCIT     OP     206      230 KV    CB             .000         .000      P
          HOMERCIT     LD     ONE      20 KV                    .000         .000      P
          HOMERCIT     X      NO.1 23  230 KV                   .000         .000      P
          HOMERCIT     U      UNIT 1   20 KV                    .000         .000      P
 2230    HomerCity.U2                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOMERCIT     U      UNIT 2   20 KV                    .000         .000       
          HOMERCIT     X      NO.2 34  345 KV                   .000         .000       
          HOMERCIT     LD     TWO      20 KV                    .000         .000       
          HOMERCIT     OP     303      345 KV    CB             .000         .000       
          HOMERCIT     OP     302      345 KV    CB             .000         .000       
 2240    HomerCity.U3                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOMERCIT     X      NO.3 34  345 KV                   .000         .000       
          HOMERCIT     LD     THREE    24 KV                    .000         .000       
          HOMERCIT     OP     305      345 KV    CB             .000         .000       
          HOMERCIT     OP     306      345 KV    CB             .000         .000       
          HOMERCIT     U      UNIT 3   24 KV                    .000         .000       
 2260    Marion.U2                                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNNYN YNNNNNNNNNNNNNNYNNNNNNNYN
          MARION       U      UNIT02   20 KV                    .000         .000      P
          MARION       OP     11-12    345 KV    CB             .000         .000      P
          MARION       X      GSU2     345 KV                   .000         .000      P
          MARION       OP     1-11     345 KV    CB             .000         .000      P
 2270    Keystone.U1                                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KEYSTONE     OP     B4       500 KV    CB             .000         .000      P
          KEYSTONE     OP     B5       500 KV    CB             .000         .000      P
          KEYSTONE     U      UNIT 1   20 KV                    .000         .000      P
          KEYSTONE     X      BK 1 50  500 KV                   .000         .000      P
 2280    Keystone.U2                                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KEYSTONE     X      BK 2 50  500 KV                   .000         .000      P
          KEYSTONE     OP     B2       500 KV    CB             .000         .000      P
          KEYSTONE     OP     B1       500 KV    CB             .000         .000      P
          KEYSTONE     U      UNIT 2   20 KV                    .000         .000      P
 2290    Limerick.U1(For TLC)                              Y Y Y S Y Y N N     NNNNNYYNNNNNNNNYNNNNNNYNN NNNNNYYNNNNNNNNYNNNNNNYNN
          LIMERICK     X      LIM1UNT  230 KV                   .000         .000      P
          LIMERICK     OP     535 CB   230 KV    CB             .000         .000      P
          LIMERICK     OP     635 CB   230 KV    CB             .000         .000      P
          LIMERICK     U      UNIT01   20 KV                    .000         .000      P
 2300    Limerick.U2(For TLC)                              Y Y Y S Y Y N N     NNNNNYYNNNNNNNNYNNNNNNNNN NNNNNYYNNNNNNNNYNNNNNNNNN
          LIMERICK     OP     335 CB   500 KV    CB             .000         .000      P
          LIMERICK     OP     235 CB   500 KV    CB             .000         .000      P
          LIMERICK     X      LIM2UNT  500 KV                   .000         .000      P
          LIMERICK     U      UNIT02   20 KV                    .000         .000      P
 2310    MartinsCreek.U3                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MARTINSC     X      G3       230 KV                   .000         .000      P
          MARTINSC     U      UNIT03   24 KV                    .000         .000      P
          MARTINSC     OP     GEN3QUA2 230 KV    CB             .000         .000      P
          MARTINSC     OP     GEN_3    230 KV    CB             .000         .000      P
 2320    MartinsCreek.U4                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MARTINSC     OP     GEN_4    230 KV    CB             .000         .000      P
          MARTINSC     X      G4       230 KV                   .000         .000      P
          MARTINSC     U      UNIT04   24 KV                    .000         .000      P
          MARTINSC     OP     GEN4SIE2 230 KV    CB             .000         .000      P
 2330    Montour.U1                                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MONTOUR      OP     GEN1 CB  24 KV     CB             .000         .000      P
          MONTOUR      X      1        230 KV                   .000         .000      P
          MONTOUR      OP     ATG1 CB  24 KV     CB             .000         .000      P
          MONTOUR      U      UNIT01   24 KV                    .000         .000      P
          MONTOUR      OP     GEN_1    230 KV    CB             .000         .000      P
          MONTOUR      OP     GEN1SUTI 230 KV    CB             .000         .000      P
 2340    Montour.U2                                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MONTOUR      OP     GEN2 CB  24 KV     CB             .000         .000      P
          MONTOUR      U      UNIT02   24 KV                    .000         .000      P
          MONTOUR      X      2        230 KV                   .000         .000      P
          MONTOUR      OP     GEN2SUSQ 230 KV    CB             .000         .000      P
          MONTOUR      OP     GEN_2    230 KV    CB             .000         .000      P
          MONTOUR      OP     ATG2 CB  24 KV     CB             .000         .000      P
 2350    Morgantown.U1                                     Y Y Y S Y Y N N     YNNNNNNNNNNYNNNNNNNNNNNYN YNNNNNNNNNNYNNNNNNNNNNNYN
          MORGANTO     U      UNIT01   23 KV                    .000         .000      P
          MORGANTO     OP     5BB      230 KV    CB             .000         .000      P
          MORGANTO     OP     5AB      230 KV    CB             .000         .000      P
          MORGANTO     X      STAF-1U  230 KV                   .000         .000      P
 2360    Morgantown.U2                                     Y Y Y S Y Y N N     YNNNNNNNNNNYNNNNNNNNNNNYN YNNNNNNNNNNYNNNNNNNNNNNYN
          MORGANTO     X      STAF-2U  230 KV                   .000         .000       
          MORGANTO     OP     6AB      230 KV    CB             .000         .000       
          MORGANTO     U      UNIT02   23 KV                    .000         .000       
          MORGANTO     OP     6BB      230 KV    CB             .000         .000       
 2370    OysterCreek.U1(for SA)                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OYSTERCR     CL     DUMNUKE5 230 KV    DIS            .000         .000      P
          OYSTERCR     CL     DUMNUKE4 230 KV    DIS            .000         .000      P
          OYSTERCR     OP     BK 1B DI 230 KV    DIS            .000         .000      P
          OYSTERCR     CL     DUMNUKE6 230 KV    DIS            .000         .000      P
          OYSTERCR     U      UNIT01   24 KV                    .000         .000      P
          OYSTERCR     CL     DUMNUKE1 230 KV    DIS            .000         .000      P
          OYSTERCR     X      1A TX 2  230 KV                   .000         .000      P
          OYSTERCR     OP     BK 1A DI 230 KV    DIS            .000         .000      P
          OYSTERCR     CL     DUMNUKE2 230 KV    DIS            .000         .000      P
          OYSTERCR     CL     DUMNUKE3 230 KV    DIS            .000         .000      P
          OYSTERCR     OP     GD1 OC   230 KV    CB             .000         .000      P
          OYSTERCR     CL     DUMNUK22 230 KV    DIS            .000         .000      P
          OYSTERCR     OP     GC1 GC   230 KV    CB             .000         .000      P
          OYSTERCR     X      1B TX 2  230 KV                   .000         .000      P
 2380    PeachBottom.U2(for SA)                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PEACHBOT     CL     DUMNK3-1 230 KV    DIS            .000         .000      P
          PEACHBOT     CL     DUMNUK11 500 KV    DIS            .000         .000      P
          PEACHBOT     CL     DUMNUKE7 500 KV    DIS            .000         .000      P
          PEACHBOT     CL     DUMNK2-3 13 KV     DIS            .000         .000      P
          PEACHBOT     CL     DUMNUKE1 230 KV    DIS            .000         .000      P
          PEACHTAP     CL     DUMNUKE1 230 KV    DIS            .000         .000      P
          PEACHBOT     OP     225 CB   500 KV    CB             .000         .000      P
          PEACHBOT     CL     DUMNK2-1 230 KV    DIS            .000         .000      P
          PEACHBOT     CL     DUMNUKE4 500 KV    DIS            .000         .000      P
          PEACHBOT     CL     DUMNUKE3 230 KV    DIS            .000         .000      P
          PEACHBOT     CL     DUMNUKE1 500 KV    DIS            .000         .000      P
          PEACHBOT     CL     DUMNUKE5 500 KV    DIS            .000         .000      P
          PEACHBOT     OP     215 CB   500 KV    CB             .000         .000      P
          PEACHBOT     CL     DUMNUKE3 500 KV    DIS            .000         .000      P
          PEACHBOT     CL     DUMNUKE6 500 KV    DIS            .000         .000      P
          PEACHBOT     CL     DUMNUKE1 13 KV     DIS            .000         .000      P
          PEACHBOT     CL     DUMNUKE8 500 KV    DIS            .000         .000      P
          PEACHBOT     CL     DUMNUK10 500 KV    DIS            .000         .000      P
          PEACHBOT     U      UNIT02   22 KV                    .000         .000      P
          PEACHBOT     CL     DUMNUKE2 230 KV    DIS            .000         .000      P
          PEACHBOT     CL     DUMNK3-3 13 KV     DIS            .000         .000      P
          PEACHBOT     X      P.B.2TR  500 KV                   .000         .000      P
          PEACHBOT     CL     DUMNUKE9 500 KV    DIS            .000         .000      P
          PEACHBOT     CL     DUMNUKE2 500 KV    DIS            .000         .000      P
 2390    PeachBottom.U2(for TLC)                           Y Y Y S Y Y N N     NNNNNYYYNNNNNNYNNNNNNNNNN NNNNNYYYNNNNNNYNNNNNNNNNN
          PEACHBOT     X      P.B.2TR  500 KV                   .000         .000       
          PEACHBOT     U      UNIT02   22 KV                    .000         .000       
          PEACHBOT     OP     225 CB   500 KV    CB             .000         .000       
          PEACHBOT     OP     215 CB   500 KV    CB             .000         .000       
 2400    PeachBottom.U3(for SA)                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PEACHBOT     CL     DUMNK2-1 230 KV    DIS            .000         .000       
          PEACHBOT     CL     DUMNUK10 500 KV    DIS            .000         .000       
          PEACHBOT     CL     DUMNUKE7 500 KV    DIS            .000         .000       
          PEACHBOT     CL     DUMNUKE1 500 KV    DIS            .000         .000       
          PEACHBOT     X      P.B.3TR  500 KV                   .000         .000       
          PEACHBOT     CL     DUMNUKE9 500 KV    DIS            .000         .000       
          PEACHBOT     CL     DUMNUKE2 230 KV    DIS            .000         .000       
          PEACHBOT     CL     DUMNK2-3 13 KV     DIS            .000         .000       
          PEACHBOT     CL     DUMNUKE2 500 KV    DIS            .000         .000       
          PEACHBOT     CL     DUMNUKE3 500 KV    DIS            .000         .000       
          PEACHBOT     CL     DUMNUK11 500 KV    DIS            .000         .000       
          PEACHBOT     CL     DUMNUKE6 500 KV    DIS            .000         .000       
          PEACHBOT     OP     65 CB    500 KV    CB             .000         .000       
          PEACHBOT     CL     DUMNUKE5 500 KV    DIS            .000         .000       
          PEACHBOT     CL     DUMNK3-3 13 KV     DIS            .000         .000       
          PEACHBOT     OP     15 CB    500 KV    CB             .000         .000       
          PEACHBOT     CL     DUMNUKE1 13 KV     DIS            .000         .000       
          PEACHBOT     CL     DUMNUKE8 500 KV    DIS            .000         .000       
          PEACHBOT     U      UNIT03   22 KV                    .000         .000       
          PEACHTAP     CL     DUMNUKE1 230 KV    DIS            .000         .000       
          PEACHBOT     CL     DUMNK3-1 230 KV    DIS            .000         .000       
          PEACHBOT     CL     DUMNUKE3 230 KV    DIS            .000         .000       
          PEACHBOT     CL     DUMNUKE4 500 KV    DIS            .000         .000       
          PEACHBOT     CL     DUMNUKE1 230 KV    DIS            .000         .000       
 2410    PeachBottom.U3(for TLC)                           Y Y Y S Y Y N N     NNNNNYYYNNNNNNYNNNNNNNNNN NNNNNYYYNNNNNNYNNNNNNNNNN
          PEACHBOT     OP     65 CB    500 KV    CB             .000         .000       
          PEACHBOT     U      UNIT03   22 KV                    .000         .000       
          PEACHBOT     OP     15 CB    500 KV    CB             .000         .000       
          PEACHBOT     X      P.B.3TR  500 KV                   .000         .000       
 2420    Salem.U1(for TLC)                                 Y Y Y S Y Y N N     NNNNNNNNNNNNNNNYNNNNNNNNN NNNNNNNNNNNNNNNYNNNNNNNNN
          SALEM        OP     SECT1-5  500 KV    CB             .000         .000       
          SALEM        U      SALEM1   25 KV                    .000         .000       
          SALEM        X      NO 1GSU  500 KV                   .000         .000       
          SALEM        OP     SECT5-6  500 KV    CB             .000         .000       
 2430    Salem.U2(for TLC)                                 Y Y Y S Y Y N N     NNNNNNNNNNNNNNNYNNNNNNNNN NNNNNNNNNNNNNNNYNNNNNNNNN
          SALEM        U      SALEM2   25 KV                    .000         .000       
          SALEM        OP     SECT1-9  500 KV    CB             .000         .000       
          SALEM        X      NO 2GSU  500 KV                   .000         .000       
          SALEM        OP     SECT9-10 500 KV    CB             .000         .000       
 2440    Susquehanna.U1 (for TLC)                          Y Y Y S Y Y N N     NNNNNNNYNNNNNNYNYNNNNNNNN NNNNNNNYNNNNNNYNYNNNNNNNN
          SUSQUEHA     OP     SYNCHRO  230 KV    CB             .000         .000       
          SUSQUEHA     X      1        230 KV                   .000         .000       
          SUSQUEHA     U      UNIT01   24 KV                    .000         .000       
 2450    Susquehanna.U1 + Relay.ESayre                     Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          SUSQUEHA     CL     DUMNUKE2 230 KV    DIS            .000         .000      P
          SUSQUEHA     CL     DUMNUKE5 500 KV    DIS            .000         .000      P
          ESAYRE       OP     N WVRLY  115 KV    CB             .000         .000      P
          SUSQUEHA     CL     DUMNUKE3 230 KV    DIS            .000         .000      P
          SUSQUEHA     X      1        230 KV                   .000         .000      P
          SUSQUEHA     CL     DUMNUKE4 500 KV    DIS            .000         .000      P
          SUSQUEHA     OP     SYNCHRO  230 KV    CB             .000         .000      P
          SUSQUEHA     CL     DUMNUKE9 230 KV    DIS            .000         .000      P
          SUSQUEHA     CL     DUMNUKE2 500 KV    DIS            .000         .000      P
          SUSQUEHA     CL     DUMNUKE5 230 KV    DIS            .000         .000      P
          SUSQUEHA     U      UNIT01   24 KV                    .000         .000      P
          SUSQUEHA     CL     DUMNUKE1 500 KV    DIS            .000         .000      P
          ESAYRE       L      ESA-NWA  115 KV                   .000         .000      P
          SUSQUEHA     CL     DUMNUKE3 500 KV    DIS            .000         .000      P
          SUSQUEHA     CL     DUMNUKE7 230 KV    DIS            .000         .000      P
          SUSQUEHA     CL     DUMNUK14 230 KV    DIS            .000         .000      P
          SUSQUEHA     CL     DUMNUK13 230 KV    DIS            .000         .000      P
          SUSQUEHA     CL     DUMNUKE6 230 KV    DIS            .000         .000      P
          SUSQUEHA     CL     DUMNUKE1 230 KV    DIS            .000         .000      P
 2460    Susquehanna.U2 (for TLC)                          Y Y Y S Y Y N N     NNNNNNNYNNNNNNYNYNNNNNNNN NNNNNNNYNNNNNNYNYNNNNNNNN
          SUSQUEHA     U      UNIT02   24 KV                    .000         .000       
          SUSQUEHA     OP     GEN_2-N  500 KV    CB             .000         .000       
          SUSQUEHA     X      2        500 KV                   .000         .000       
          SUSQUEHA     OP     GEN_2-S  500 KV    CB             .000         .000       
 2470    TMI.U1 (for TLC)                                  Y Y Y S Y Y N N     NNNNNYNYNNNNNNYNNNNNNNNNN NNNNNYNYNNNNNNYNNNNNNNNNN
          TMI          OP     GB1-02   230 KV    CB             .000         .000      P
          TMI          OP     GB1-12   230 KV    CB             .000         .000      P
          TMI          X      1B TX 2  230 KV                   .000         .000      P
          TMI          U      UNIT01   20 KV                    .000         .000      P
          TMI          X      1A TX 2  230 KV                   .000         .000      P
 2480    Chateaguay.AC-Gen                                 Y Y Y L Y Y N N     NNNNYNNNNNNNNNNNNNYNNNNNN NNNNYNNNNNNNNNNNNNYNNNNNN
          CHATEAUG     U      AC-GEN   765 KV                   .000         .000      P
          CHATEAUG     OP     CB 04    765 KV    CB             .000         .000      P
 2490    Millstone.U1                                      Y Y Y L Y Y N N     NNNNYNNNNNNNNNNNNNYNNNNNN NNNNYNNNNNNNNNNNNNYNNNNNN
          MILLSTON     U      GEN  1   345 KV                   .000         .000      P
          MILLSTON     OP     UNIT 1   345 KV    CB             .000         .000      P
 2500    Millstone.U2                                      Y Y Y L Y Y N N     NNNNYNNNNNNNNNNNNNYNNNNNN NNNNYNNNNNNNNNNNNNYNNNNNN
          MILLSTON     U      GEN  2   345 KV                   .000         .000      P
          MILLSTON     OP     UNIT 2   345 KV    CB             .000         .000      P
 2510    Millstone.U3                                      Y Y Y L Y Y N N     NNNNYNNNNNNNNNNNNNYNNNNNN NNNNYNNNNNNNNNNNNNYNNNNNN
          MILLSTON     U      GEN  3   345 KV                   .000         .000      P
          MILLSTON     OP     UNIT 3   345 KV    CB             .000         .000      P
 2520    NE ISO LARGEST UNIT TRIP (SIMULATED AT SANDYPOND) Y Y Y L Y Y N N     NNNNYNNNNNNNNNNNNNYNYYNNN NNNNYNNNNNNNNNNNNNYNYYNNN
          SANDYPON     U      HQHVDC   345 KV                   .000         .000      P
 2530    Comerford.HVDC.Tie                                Y Y Y L Y Y N N     NNNNYNNNNNNNNNNNNNYNNNNNN NNNNYNNNNNNNNNNNNNYNNNNNN
          COMERFOR     OP     345UNIT  345 KV    CB             .000         .000      P
          COMERFOR     U      HQHVDC   345 KV                   .000         .000      P
 2540    Highgate.HVDC.Tie                                 Y Y Y L Y Y N N     NNNNYNNNNNNNNNNNNNYNNNNNN NNNNYNNNNNNNNNNNNNYNNNNNN
          HIGHGATE     U      HQHVDC   115 KV                   .000         .000      P
          HIGHGATE     OP     115 UNIT 115 KV    CB             .000         .000      P
 2550    NewBrunswick.HVDC.Tie                             Y Y Y L Y Y N N     NNNNYNNNNNNNNNNNNNYNNNNNN NNNNYNNNNNNNNNNNNNYNNNNNN
          HQNEWBRU     OP     345 UNIT 345 KV    CB             .000         .000       
          HQNEWBRU     U      HQHVDC   345 KV                   .000         .000       
 2560    L765.Chateauguay-Massena                          Y Y Y L Y Y N N     NNNNYNNNNNNNNNNNNNYNNNNNN NNNNYNNNNNNNNNNNNNYNNNNNN
          MASSENA      OP     7102     765 KV    CB             .000         .000       
          CHATEAUG     L      CHA-MAS  765 KV                   .000         .000       
          MASSENA      OP     7108     765 KV    CB             .000         .000       
          CHATEAUG     OP     CB 01    765 KV    CB             .000         .000       
 2570    L230.MartinsCreek-Portland.1008                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          MARTINSC     OP     PORT     230 KV    CB             .000         .000      P
          MARTINSC     L      MAR-POR  230 KV                   .000         .000      P
          PORTLAND     OP     100812   230 KV    CB             .000         .000      P
          MARTINSC     OP     BRK A    230 KV    CB             .000         .000      P
 2580    L230.Portland-Greystone.S1007                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GREYSTON     OP     BK 3 DI  230 KV    DIS            .000         .000      P
          GREYSTON     LD     BK 3     230 KV                   .000         .000      P
          PORTLAND     L      GRE-POR  230 KV                   .000         .000      P
          PORTLAND     OP     100712   230 KV    CB             .000         .000      P
          GREYSTON     OP     S1007 AC 230 KV    CB             .000         .000      P
 2590    Bergen.CC1                                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BERGEN       U      CC13     18 KV                    .000         .000       
          BERGEN       U      CC12     18 KV                    .000         .000       
          BERGEN       X      CC13-14  138 KV                   .000         .000       
          BERGEN       OP     A-1301   138 KV    CB             .000         .000       
          BERGEN       OP     CC14 GEN 18 KV     CB             .000         .000       
          BERGEN       U      UNIT 1   18 KV                    .000         .000       
          BERGEN       X      CC11-12  138 KV                   .000         .000       
          BERGEN       OP     1112     138 KV    CB             .000         .000       
          BERGEN       U      CC14     18 KV                    .000         .000       
          BERGEN       OP     CC11 GEN 18 KV     CB             .000         .000       
          BERGEN       U      CC11     18 KV                    .000         .000       
          BERGEN       OP     CC13 GEN 18 KV     CB             .000         .000       
          BERGEN       OP     1314     138 KV    CB             .000         .000       
          BERGEN       OP     CC12 GEN 18 KV     CB             .000         .000       
 2600    Bergen.2CC (2001 STM/2101 CT1/2202 CT2)           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BERGEN       OP     22CT CB  230 KV    CB             .000         .000       
          BERGEN       OP     2STM CB  230 KV    CB             .000         .000       
          BERGEN       U      2001 STM 18 KV                    .000         .000       
          BERGEN       U      2202 CT2 18 KV                    .000         .000       
          BERGEN       OP     21CT CB  230 KV    CB             .000         .000       
          BERGEN       U      2101 CT1 18 KV                    .000         .000       
 2620    BrunnerIsland.U1                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRUNNERI     OP     GEN_1    230 KV    CB             .000         .000       
          BRUNNERI     X      1        230 KV                   .000         .000       
          BRUNNERI     U      UNIT01   18 KV                    .000         .000       
 2630    BrunnerIsland.U2                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRUNNERI     U      UNIT02   18 KV                    .000         .000      P
          BRUNNERI     OP     GEN_2    230 KV    CB             .000         .000      P
          BRUNNERI     X      2        230 KV                   .000         .000      P
 2640    Burlington.CT121 + CT122 + CT123 + CT124          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BURLINGT     U      UNIT123  13 KV                    .000         .000       
          BURLINGT     X      TR123    138 KV                   .000         .000       
          BURLINGT     U      UNIT121  13 KV                    .000         .000       
          BURLINGT     X      TR124    138 KV                   .000         .000       
          BURLINGT     X      TR121    138 KV                   .000         .000       
          BURLINGT     OP     1-3      230 KV    CB             .000         .000       
          BURLINGT     U      UNIT122  13 KV                    .000         .000       
          BURLINGT     U      UNIT124  13 KV                    .000         .000       
          BURLINGT     OP     2-3      230 KV    CB             .000         .000       
          BURLINGT     X      TR122    138 KV                   .000         .000       
 2660    L138.Burlingtn-Levitwn-Cinam-Camdn.J1310&BuCT91-94Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BURLINGT     OP     1-10     230 KV    CB             .000         .000       
 2670    BURLINGTON CT UNITS 101-105                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BURLINGT     OP     TR12L    138 KV    DIS            .000         .000      P
 2690    ChalkPoint.U1                                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHALKPT      U      CHLKG1   20 KV                    .000         .000      P
          CHALKPT      OP     4BB      230 KV    CB             .000         .000      P
          CHALKPT      X      STAE-U1  230 KV                   .000         .000      P
          CHALKPT      OP     4CB      230 KV    CB             .000         .000      P
 2700    ChalkPoint.U2                                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHALKPT      U      CHLKG2   20 KV                    .000         .000      P
          CHALKPT      OP     5CB      230 KV    CB             .000         .000      P
          CHALKPT      OP     5BB      230 KV    CB             .000         .000      P
          CHALKPT      X      STAE-U2  230 KV                   .000         .000      P
 2710    Crane.U1                                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CRANE        X      U1 XFMR  115 KV                   .000         .000      P
          CRANE        L      CRA-WIN1 115 KV                   .000         .000      P
          CRANE        OP     1GENSYN  115 KV    CB             .000         .000      P
          CRANE        U      GEN 01   20 KV                    .000         .000      P
 2720    Crane.U2                                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CRANE        X      U2 XFMR  115 KV                   .000         .000      P
          CRANE        L      CRA-WIN2 115 KV                   .000         .000      P
          CRANE        OP     2GENSYN  115 KV    CB             .000         .000      P
          CRANE        U      GEN 02   20 KV                    .000         .000      P
 2730    Dickerson.U1                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DICKERSO     OP     1BB      230 KV    CB             .000         .000      P
          DICKERSO     X      STADG1T  230 KV                   .000         .000      P
          DICKERSO     OP     1CB      230 KV    CB             .000         .000      P
          DICKERSO     U      STADG1   13 KV                    .000         .000      P
 2740    Dickerson.U2                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DICKERSO     U      STADG2   13 KV                    .000         .000      P
          DICKERSO     OP     2BB      230 KV    CB             .000         .000      P
          DICKERSO     X      STADGT2  230 KV                   .000         .000      P
          DICKERSO     OP     2CB      230 KV    CB             .000         .000      P
 2750    Dickerson.U3                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DICKERSO     X      STADG3T  230 KV                   .000         .000      P
          DICKERSO     OP     3CB      230 KV    CB             .000         .000      P
          DICKERSO     OP     3BB      230 KV    CB             .000         .000      P
          DICKERSO     U      STADG3   13 KV                    .000         .000      P
 2780    Edgemoor.U4                                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDGEMOOR     U      UNIT04   19 KV                    .000         .000      P
          EDGEMOOR     OP     3-2      138 KV    CB             .000         .000      P
          EDGEMOOR     OP     3-1      138 KV    CB             .000         .000      P
          EDGEMOOR     X      T4       138 KV                   .000         .000      P
 2790    Edgemoor.U5                                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDGEMOOR     OP     235      230 KV    CB             .000         .000      P
          EDGEMOOR     X      T5       230 KV                   .000         .000      P
          EDGEMOOR     OP     234      230 KV    CB             .000         .000      P
          EDGEMOOR     U      UNIT05   23 KV                    .000         .000      P
 2810    England.U2                                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ENGLAND      U      UNIT02   18 KV                    .000         .000      P
          ENGLAND      X      ENG #2   138 KV                   .000         .000      P
          ENGLAND      OP     452-F    138 KV    CB             .000         .000      P
          ENGLAND      OP     452-E    138 KV    CB             .000         .000      P
 2820    England.U3                                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ENGLAND      OP     452-I    138 KV    CB             .000         .000      P
          ENGLAND      U      UNIT03   20 KV                    .000         .000      P
          ENGLAND      OP     452-J    138 KV    CB             .000         .000      P
          ENGLAND      X      ENG #3   138 KV                   .000         .000      P
 2850    IndianRiver.U3                                    Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          INDIANRI     U      UNIT03   20 KV                    .000         .000      P
          INDIANRI     OP     8026     138 KV    CB             .000         .000      P
          INDIANRI     X      TG3      138 KV                   .000         .000      P
 2860    IndianRiver.CT10                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          INDIANRI     U      UNIT10   13 KV                    .000         .000      P
          INDIANRI     X      TG10     69 KV                    .000         .000      P
          INDIANRI     OP     7060     69 KV     CB             .000         .000      P
 2870    IndianRiver.U4                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          INDIANRI     OP     9445     230 KV    CB             .000         .000      P
          INDIANRI     X      TG4      230 KV                   .000         .000      P
          INDIANRI     U      UNIT04   26 KV                    .000         .000      P
 2880    Vienna.U8                                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          VIENNA       OP     8140     138 KV    CB             .000         .000      P
          VIENNA       OP     8190     138 KV    CB             .000         .000      P
          VIENNA       X      T8       138 KV                   .000         .000      P
          VIENNA       U      UNIT08   18 KV                    .000         .000      P
 2890    Independence.6CC (NYISO)                          Y Y Y S Y Y N N     YNNNYNNNNNNNNNNNNNNNNNNYN YNNNYNNNNNNNNNNNNNNNNNNYN
          INDEPEND     U      ST6      18 KV                    .000         .000       
          INDEPEND     OP     R270     345 KV    CB             .000         .000       
          INDEPEND     U      GT4      18 KV                    .000         .000       
          INDEPEND     U      GT3      18 KV                    .000         .000       
          INDEPEND     OP     R915     345 KV    CB             .000         .000       
 2900    JAFitzpatrick.U1                                  Y Y Y S Y Y N N     YNNNYNNNNNNNNNNNNNNNNNNYN YNNNYNNNNNNNNNNNNNNNNNNYN
          JAFITZP      U      GEN  1   345 KV                   .000         .000      P
 2930    230/69.MartinsCreek.T21                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          MARTINSC     OP     TR21NTIE 230 KV    CB             .000         .000      P
          MARTINSC     OP     TRAN_21  69 KV     CB             .000         .000      P
          MARTINSC     X      21       230 KV                   .000         .000      P
          MARTINSC     OP     TR_21    230 KV    CB             .000         .000      P
          MARTINSC     OP     DUM19216 69 KV     DIS            .000         .000      P
 2950    Mercer.U1                                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MERCER       OP     SECT1-6  230 KV    CB             .000         .000      P
          MERCER       OP     SECT1-2  230 KV    CB             .000         .000      P
          MERCER       U      UNIT01   18 KV                    .000         .000      P
          MERCER       X      220-1    230 KV                   .000         .000      P
 2960    Mercer.U2                                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MERCER       OP     SECT2-3  230 KV    CB             .000         .000      P
          MERCER       OP     SECT3-4  230 KV    CB             .000         .000      P
          MERCER       X      220-2    230 KV                   .000         .000      P
          MERCER       U      UNIT02   18 KV                    .000         .000      P
 2970    Portland.U2                                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PORTLAND     X      G2 TX 2  230 KV                   .000         .000      P
          PORTLAND     OP     GEN2UNIT 230 KV    CB             .000         .000      P
          PORTLAND     U      UNIT 2   15 KV                    .000         .000      P
 2980    Portland.U1                                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PORTLAND     X      G1 TX 1  115 KV                   .000         .000      P
          PORTLAND     OP     G12      115 KV    CB             .000         .000      P
          PORTLAND     U      UNIT 1   13 KV                    .000         .000      P
 2990    Riverside.U4                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RIVERSID     U      GEN 04   13 KV                    .000         .000      P
          RIVERSID     X      U4 XF    115 KV                   .000         .000      P
          RIVERSID     OP     4GENSYN  115 KV    CB             .000         .000      P
 3000    Sewaren.U1                                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SEWAREN      U      UNIT01   13 KV                    .000         .000      P
          SEWAREN      OP     261AGRPI 26 KV     CB             .000         .000      P
          SEWAREN      OP     261BGRPM 26 KV     CB             .000         .000      P
          SEWAREN      X      26-1A    26 KV                    .000         .000      P
          SEWAREN      X      26-1B    26 KV                    .000         .000      P
 3010    Sewaren.U2                                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SEWAREN      X      132-2    138 KV                   .000         .000      P
          SEWAREN      U      UNIT02   13 KV                    .000         .000      P
          SEWAREN      OP     132-2 CB 13 KV     CB             .000         .000      P
          SEWAREN      X      26-2     26 KV                    .000         .000      P
 3020    Sewaren.U3                                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SEWAREN      OP     132-3 CB 13 KV     CB             .000         .000      P
          SEWAREN      X      26-3     26 KV                    .000         .000      P
          SEWAREN      X      132-3    138 KV                   .000         .000      P
          SEWAREN      U      UNIT03   13 KV                    .000         .000      P
          SEWAREN      OP     26-3 CB  13 KV     CB             .000         .000      P
 3030    Sewaren.U4                                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SEWAREN      OP     NO 4 GEN 16 KV     DIS            .000         .000      P
          SEWAREN      X      132-4    138 KV                   .000         .000      P
          SEWAREN      U      UNIT04   16 KV                    .000         .000      P
 3040    Shawville.U3                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHAWVILL     U      UNIT 3   22 KV                    .000         .000      P
          SHAWVILL     X      BNK #3   230 KV                   .000         .000      P
          SHAWVILL     OP     NO3TX230 230 KV    CB             .000         .000      P
 3050    Shawville.U4                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHAWVILL     U      UNIT 4   22 KV                    .000         .000       
          SHAWVILL     X      BNK #4   230 KV                   .000         .000       
          SHAWVILL     OP     NO4TX230 230 KV    CB             .000         .000       
 3070    Wagner.U4                                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRANDONS     L      BRA-WAG4 230 KV                   .000         .000      P
          BRANDONS     OP     130001OC 230 KV    CB             .000         .000      P
          WAGNER       U      GEN 04   13 KV                    .000         .000      P
          BRANDONS     OP     4GENOCB  230 KV    CB             .000         .000      P
 3080    Wagner.U1                                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WAGNER       X      U1 XF    115 KV                   .000         .000       
          WAGNER       U      GEN 01   13 KV                    .000         .000       
          WAGNER       OP     1GENSYNA 115 KV    CB             .000         .000       
 3090    Wagner.U2                                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WAGNER       X      U2 XF    115 KV                   .000         .000      P
          WAGNER       OP     P4000-2  115 KV    CB             .000         .000      P
          WAGNER       U      GEN 02   13 KV                    .000         .000      P
          WAGNER       OP     2GENSYNA 115 KV    CB             .000         .000      P
 3100    Wagner.U3                                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WAGNER       OP     3GENSYN  115 KV    CB             .000         .000      P
          WAGNER       X      U3 XF    115 KV                   .000         .000      P
          WAGNER       U      GEN 03   13 KV                    .000         .000      P
 3120    L34.Westport-GouldStreet.33851                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WESTPORT     OP     33851BBB 34 KV     CB             .000         .000       
          WESTPORT     P      PAR33851 34 KV                    .000         .000       
          GOULDST      OP     33851CB  34 KV     CB             .000         .000       
          GOULDST      L      GOU-WES1 34 KV                    .000         .000       
          WESTPORT     OP     33851RBB 34 KV     CB             .000         .000       
 3130    L500.Branchburg-Elroy.5017 + Elroy.T1&T2          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNNYN YNNNNNNNNNNNNNNYNNNNNNNYN
          ELROY        OP     175 CB   500 KV    CB             .000         .000      P
          ELROYPL      OP     TRAN2DIS 138 KV    CB             .000         .000      P
          ELROYPL      X      1 TR     500 KV                   .000         .000      P
          ELROY        OP     475 CB   500 KV    CB             .000         .000      P
          ELROYPL      OP     TRAN2    69 KV     CB             .000         .000      P
          BRANCHBU     OP     SECT 5-6 500 KV    CB             .000         .000      P
          ELROYPL      OP     TRAN1    500 KV    CB             .000         .000      P
          BRANCHBU     OP     SECT 6-7 500 KV    CB             .000         .000      P
          ELROYPL      X      2 TR     138 KV                   .000         .000      P
          ELROY        L      BRA-ELR  500 KV                   .000         .000      P
          ELROYPL      OP     TRAN1DIS 138 KV    CB             .000         .000      P
 3150    L500.NewFreedom-Salem.5024                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNYYN YNNNNNNNNNNNNNNYNNNNNNYYN
          NEWFREED     OP     SECT7-8  500 KV    CB             .000         .000      P
          SALEM        OP     SECT2-6  500 KV    CB             .000         .000      P
          NEWFREED     OP     SECT2-8  500 KV    CB             .000         .000      P
          NEWFREED     OP     5024     500 KV    DIS            .000         .000      P
          SALEM        OP     SECT5-6  500 KV    CB             .000         .000      P
          NEWFREED     L      NEW-SAL  500 KV                   .000         .000      P
 3160    L500.Hosensack-Elroy.5028 + 500/138.Elroy.T3      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNYYN YNNNNNNNNNNNNNNYNNNNNNYYN
          HOSENSAC     OP     ELROY CB 500 KV    CB             .000         .000      P
          ELROY        L      ELR-ELR1 500 KV                   .000         .000      P
          HOSENSAC     OP     EL-TMI   500 KV    CB             .000         .000      P
          HOSENSAC     OP     DIS 5028 500 KV    DIS            .000         .000      P
          ELROYPL      OP     TRAN3    500 KV    CB             .000         .000      P
          ELROY        OP     145 CB   500 KV    CB             .000         .000      P
          ELROYPL      X      3 TR     500 KV                   .000         .000      P
          ELROY        OP     475 CB   500 KV    CB             .000         .000      P
          ELROY        L      ELR-HOS  500 KV                   .000         .000      P
 3170    L500.Limerick-PeachBottom.5010                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNYYN YNNNNNNNNNNNNNNYNNNNNNYYN
          LIMERICK     OP     225 CB   500 KV    CB             .000         .000      P
          PEACHBOT     OP     103 DIS  500 KV    DIS            .000         .000      P
          LIMERICK     OP     101 DIS  500 KV    DIS            .000         .000      P
          PEACHBOT     OP     65 CB    500 KV    CB             .000         .000      P
          LIMERICK     OP     325 CB   500 KV    CB             .000         .000      P
          PEACHBOT     OP     55 CB    500 KV    CB             .000         .000      P
          LIMERICK     L      LIM-PEA  500 KV                   .000         .000      P
 3180    L500.PeachBottom-TMI.5007                         Y Y Y S Y Y N N     YNNNNNNYNNNNNNYYNNNNNNYYN YNNNNNNYNNNNNNYYNNNNNNYYN
          PEACHBOT     L      PEA-TMI  500 KV                   .000         .000      P
          TMI          OP     500702   500 KV    CB             .000         .000      P
          TMI          OP     070802   500 KV    CB             .000         .000      P
          PEACHBOT     OP     25 CB    500 KV    CB             .000         .000      P
          PEACHBOT     OP     35 CB    500 KV    CB             .000         .000      P
 3190    L500.PeachBottom-TMI.5007 + MuddyRun.U5-8         Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          MUDDYRN      U      UNIT5    13 KV                    .000         .000      P
          MUDDYRN      U      UNIT8    13 KV                    .000         .000      P
          MUDDYRN      U      UNIT7    13 KV                    .000         .000      P
          PEACHBOT     OP     1T3 DIS  500 KV    DIS            .000         .000      P
          PEACHBOT     OP     675 CB   230 KV    CB             .000         .000      P
          PEACHBOT     OP     25 CB    500 KV    CB             .000         .000      P
          PEACHBOT     L      PEA-TMI  500 KV                   .000         .000      P
          TMI          OP     500702   500 KV    CB             .000         .000      P
          PEACHBOT     X      1-P      500 KV                   .000         .000      P
          MUDDYRN      OP     8 GEN CB 13 KV     CB             .000         .000      P
          PEACHBOT     OP     45 CB    500 KV    CB             .000         .000      P
          MUDDYRN      OP     6 GEN CB 13 KV     CB             .000         .000      P
          PEACHBOT     OP     473      230 KV    DIS            .000         .000      P
          MUDDYRN      OP     075 CB   230 KV    CB             .000         .000      P
          PEACHBOT     OP     175 CB   230 KV    CB             .000         .000      P
          MUDDYRN      OP     5 GEN CB 13 KV     CB             .000         .000      P
          PEACHBOT     OP     SU35     13 KV     CB             .000         .000      P
          PEACHBOT     OP     073 DIS  230 KV    DIS            .000         .000      P
          TMI          OP     070802   500 KV    CB             .000         .000      P
          PEACHBOT     X      1-S      230 KV                   .000         .000      P
          TMI          OP     DIS 5007 500 KV    DIS            .000         .000      P
          MUDDYRN      U      UNIT6    13 KV                    .000         .000      P
          PEACHBOT     OP     35 CB    500 KV    CB             .000         .000      P
          MUDDYRN      X      MR 3TR   230 KV                   .000         .000      P
          PEACHBOT     OP     475      230 KV    CB             .000         .000      P
          MUDDYRN      L      MUD-PEA7 230 KV                   .000         .000      P
          MUDDYRN      X      MR 4TR   230 KV                   .000         .000      P
          PEACHBOT     X      1-T      13 KV                    .000         .000      P
          MUDDYRN      OP     7 GEN CB 13 KV     CB             .000         .000      P
 3200    L500.Alburtis-Branchburg.5016                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNYYN YNNNNNNNNNNNNNNYNNNNNNYYN
          ALBURTIS     OP     DUM4     500 KV    DIS            .000         .000      P
          ALBURTIS     OP     BREI2BRN 500 KV    CB             .000         .000      P
          ALBURTIS     L      ALB-BRA  500 KV                   .000         .000      P
          BRANCHBU     OP     8-16     500 KV    CB             .000         .000      P
          BRANCHBU     OP     5016     500 KV    DIS            .000         .000      P
          BRANCHBU     OP     16-17    500 KV    CB             .000         .000      P
          ALBURTIS     OP     BRAN     500 KV    CB             .000         .000      P
 3210    L500.Alburtis-Hosensack.5027                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          ALBURTIS     L      ALB-HOS  500 KV                   .000         .000      P
          HOSENSAC     OP     ALBU     500 KV    CB             .000         .000      P
          HOSENSAC     OP     ELROY CB 500 KV    CB             .000         .000      P
          ALBURTIS     OP     JUNIHOSE 500 KV    CB             .000         .000      P
          HOSENSAC     OP     DIS 5027 500 KV    DIS            .000         .000      P
          ALBURTIS     OP     HOSE     500 KV    CB             .000         .000      P
 3220    L500.Alburtis-Juniata.5009                        Y Y Y S Y Y N N     YNNNNNNYNNNNNNYYNNNNNNYYN YNNNNNNYNNNNNNYYNNNNNNYYN
          ALBURTIS     OP     DUM3     500 KV    DIS            .000         .000       
          ALBURTIS     OP     JUNIHOSE 500 KV    CB             .000         .000       
          JUNIATA      OP     DIS 5009 500 KV    DIS            .000         .000       
          ALBURTIS     L      ALB-JUN  500 KV                   .000         .000       
          ALBURTIS     OP     JUNI     500 KV    CB             .000         .000       
          JUNIATA      OP     ALBU     500 KV    CB             .000         .000       
          JUNIATA      OP     KEYSALBU 500 KV    CB             .000         .000       
 3230    L500.Juniata-Keystone.5004                        Y Y Y S Y Y N N     YNNNNYYYNNNYNNYYYNNNNNYYN YNNNNYYYNNNYNNYYYNNNNNYYN
          JUNIATA      OP     KEYS     500 KV    CB             .000         .000       
          JUNIATA      OP     KEYSALBU 500 KV    CB             .000         .000       
          KEYSTONE     OP     B3       500 KV    CB             .000         .000       
          KEYSTONE     OP     B2       500 KV    CB             .000         .000       
          KEYSTONE     OP     DIS5004  500 KV    DIS            .000         .000       
          JUNIATA      OP     DIS 5004 500 KV    DIS            .000         .000       
          JUNIATA      L      JUN-KEY  500 KV                   .000         .000       
 3240    L500.Juniata-TMI.5008                             Y Y Y S Y Y N N     YNNNNNNYNNNNNNYYNNNNNNYYN YNNNNNNYNNNNNNYYNNNNNNYYN
          JUNIATA      OP     CONETMIS 500 KV    CB             .000         .000      P
          TMI          OP     500802   500 KV    CB             .000         .000      P
          TMI          OP     DIS 5008 500 KV    DIS            .000         .000      P
          JUNIATA      L      JUN-TMI  500 KV                   .000         .000      P
          TMI          OP     070802   500 KV    CB             .000         .000      P
          JUNIATA      OP     DIS 5008 500 KV    DIS            .000         .000      P
          JUNIATA      OP     TMIS     500 KV    CB             .000         .000      P
 3300    L500.Conastone-PeachBottom.5012                   Y Y Y S Y Y N N     YNNNNYNYNNNNNNYYNNNNNNYYN YNNNNYNYNNNNNNYYNNNNNNYYN
          CONASTON     OP     500 C CB 500 KV    CB             .000         .000      P
          PEACHBOT     OP     123 DIS  500 KV    DIS            .000         .000      P
          CONASTON     OP     500 B CB 500 KV    CB             .000         .000      P
          PEACHBOT     OP     235 CB   500 KV    CB             .000         .000      P
          PEACHBOT     L      CNS-PEA  500 KV                   .000         .000      P
          CONASTON     OP     5012DSW  500 KV    DIS            .000         .000      P
          PEACHBOT     OP     245 CB   500 KV    CB             .000         .000      P
 3310    L500.Conemaugh-Juniata.5005                       Y Y Y S Y Y N N     YNNNNYYYNNNYNNYYYNNNNNYYN YNNNNYYYNNNYNNYYYNNNNNYYN
          JUNIATA      OP     DIS 5005 500 KV    DIS            .000         .000      P
          CONEMAUG     OP     DIS5005  500 KV    DIS            .000         .000      P
          CONEMAUG     OP     B4       500 KV    CB             .000         .000      P
          JUNIATA      OP     CONETMIS 500 KV    CB             .000         .000      P
          JUNIATA      L      CNM-JUN  500 KV                   .000         .000      P
          CONEMAUG     OP     B5       500 KV    CB             .000         .000      P
          JUNIATA      OP     CONE     500 KV    CB             .000         .000      P
 3320    L500.Conemaugh-Keystone.5003                      Y Y Y S Y Y N N     YNNNNYYYNNNNNNYYYNNNNNYYN YNNNNYYYNNNNNNYYYNNNNNYYN
          CONEMAUG     OP     B3       500 KV    CB             .000         .000      P
          CONEMAUG     L      CNM-KEY  500 KV                   .000         .000      P
          KEYSTONE     OP     B6       500 KV    CB             .000         .000      P
          KEYSTONE     OP     B5       500 KV    CB             .000         .000      P
          CONEMAUG     OP     DIS 5003 500 KV    DIS            .000         .000      P
          KEYSTONE     OP     DIS 5003 500 KV    DIS            .000         .000      P
          CONEMAUG     OP     B2       500 KV    CB             .000         .000      P
 3330    L500.Keystone-SouthBend.5001(513)                 Y Y Y S Y Y N N     YNNNNYYYNNNNNNYNYNNNNNYYN YNNNNYYYNNNNNNYNYNNNNNYYN
          KEYSTONE     OP     DIS 5001 500 KV    DIS            .000         .000      P
          SBEND        OP     SBL1     500 KV    CB             .000         .000      P
          KEYSTONE     OP     B8       500 KV    CB             .000         .000      P
          KEYSTONE     OP     B9       500 KV    CB             .000         .000      P
          SBEND        OP     SBL2     500 KV    CB             .000         .000      P
          SBEND        OP     DUMKEYST 500 KV    DIS            .000         .000      P
          KEYSTONE     L      KEY-SBE  500 KV                   .000         .000      P
 3340    L500.Cabot-Keystone.5002                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          CABOT        OP     CB 05    500 KV    CB             .000         .000      P
          KEYSTONE     OP     B16      500 KV    CB             .000         .000      P
          KEYSTONE     OP     B14      500 KV    CB             .000         .000      P
          CABOT        OP     CB 06    500 KV    CB             .000         .000      P
          KEYSTONE     L      CAB-KEY  500 KV                   .000         .000      P
 3350    L500.Keeney-RockSprings.5025                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNYYN YNNNNNNNNNNNNNNYNNNNNNYYN
          ROCKSPRI     OP     89-5C    500 KV    DIS            .000         .000      P
          ROCKSPRI     OP     52-5     500 KV    CB             .000         .000      P
          KEENEY       L      KEE-ROC  500 KV                   .000         .000      P
          KEENEY       OP     5025-L1  500 KV    DIS            .000         .000      P
          KEENEY       OP     501      500 KV    CB             .000         .000      P
          KEENEY       OP     505      500 KV    CB             .000         .000      P
          ROCKSPRI     OP     52-4     500 KV    CB             .000         .000      P
 3380    L500.Bedington-BlackOak                           Y Y Y S Y Y N N     YNNNNNYNNNNYNNYYYNNYNNYYN YNNNNNYNNNNYNNYYYNNYNNYYN
          BLACKOAK     OP     BOL3 CB  500 KV    CB             .000         .000      P
          BEDINGTO     OP     BLACKOAK 500 KV    DIS            .000         .000      P
          BEDINGTO     OP     BDL4 CB  500 KV    CB             .000         .000      P
          BLACKOAK     OP     BEDINGTO 500 KV    DIS            .000         .000      P
          BLACKOAK     L      BED-BLA  500 KV                   .000         .000      P
          BEDINGTO     OP     BDL3 CB  500 KV    CB             .000         .000      P
          BLACKOAK     OP     BOL2 CB  500 KV    CB             .000         .000      P
 3390    L500.Bedington-Doubs                              Y Y Y S Y Y N N     YNNNNNYNNNNNNNNNYNNNNNYYN YNNNNNYNNNNNNNNNYNNNNNYYN
          DOUBS        OP     DUM18383 500 KV    DIS            .000         .000      P
          DOUBS        OP     CB 51    500 KV    CB             .000         .000      P
          BEDINGTO     OP     BDL2 CB  500 KV    CB             .000         .000      P
          BEDINGTO     OP     DOUBS    500 KV    DIS            .000         .000      P
          BEDINGTO     OP     BDL1 CB  500 KV    CB             .000         .000      P
          BEDINGTO     L      BED-DOU  500 KV                   .000         .000      P
          DOUBS        OP     CB 54    500 KV    CB             .000         .000      P
 3400    L500.MtStorm-Pruntytown.554                       Y Y Y S Y Y N N     YNNNNYYNNNNYNNNNYNNNNNYYN YNNNNYYNNNNYNNNNYNNNNNYYN
          MTSTORM4     OP     DUM5     500 KV    DIS            .000         .000      P
          MTSTORM4     OP     554TB4   500 KV    CB             .000         .000      P
          MTSTORM4     OP     554TB3   500 KV    CB             .000         .000      P
          PRUNTYTO     OP     PL5 CB   500 KV    CB             .000         .000      P
          PRUNTYTO     L      MTS-PRU  500 KV                   .000         .000      P
          PRUNTYTO     OP     MTSTORM_ 500 KV    DIS            .000         .000      P
          PRUNTYTO     OP     PL4 CB   500 KV    CB             .000         .000      P
 3410    500/230.Branchburg.500-1                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRANCHBU     X      500-1    500 KV                   .000         .000       
          BRANCHBU     OP     SECT9-10 230 KV    CB             .000         .000       
          BRANCHBU     OP     SECT9-13 230 KV    CB             .000         .000       
          BRANCHBU     OP     500-1HCB 500 KV    CB             .000         .000       
 3420    500/230.Branchburg.500-2                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRANCHBU     X      500-2    500 KV                   .000         .000      P
          BRANCHBU     OP     SECT 2-8 230 KV    CB             .000         .000      P
          BRANCHBU     OP     500-2HCB 500 KV    CB             .000         .000      P
          BRANCHBU     OP     5002_LSD 230 KV    DIS            .000         .000      P
          BRANCHBU     OP     SECT 7-8 230 KV    CB             .000         .000      P
 3430    500/230.NewFreedom.500-1                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          NEWFREED     OP     SECT3-4  500 KV    CB             .000         .000       
          NEWFREED     OP     230 1-3  230 KV    CB             .000         .000       
          NEWFREED     OP     SECT1-3  500 KV    CB             .000         .000       
          NEWFREED     X      500 1    500 KV                   .000         .000       
          NEWFREED     OP     230 3-4  230 KV    CB             .000         .000       
 3440    500/230.NewFreedom.500-2                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          NEWFREED     OP     230 1-5  230 KV    CB             .000         .000      P
          NEWFREED     OP     SECT1-5  500 KV    CB             .000         .000      P
          NEWFREED     X      500-2    500 KV                   .000         .000      P
          NEWFREED     OP     230 5-6  230 KV    CB             .000         .000      P
          NEWFREED     OP     SECT5-6  500 KV    CB             .000         .000      P
 3450    500/230.NewFreedom.500-3                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          NEWFREED     OP     SECT7-8  500 KV    CB             .000         .000      P
          NEWFREED     OP     230 7-8  230 KV    CB             .000         .000      P
          NEWFREED     OP     230 1-7  230 KV    CB             .000         .000      P
          NEWFREED     OP     SECT1-7  500 KV    CB             .000         .000      P
          NEWFREED     X      500-3    500 KV                   .000         .000      P
 3460    500/230.NewFreedom.500-4                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          NEWFREED     X      500-4    500 KV                   .000         .000      P
          NEWFREED     OP     SECT9-10 500 KV    CB             .000         .000      P
          NEWFREED     OP     SECT1-9  500 KV    CB             .000         .000      P
          NEWFREED     OP     11_12    230 KV    CB             .000         .000      P
          NEWFREED     OP     1-11     230 KV    CB             .000         .000      P
 3470    500/230.Juniata.T2                                Y Y Y S Y Y N N     YNNNNNNYNNNNNNYNYNNNNNNYN YNNNNNNYNNNNNNYNYNNNNNNYN
          JUNIATA      X      2        500 KV                   .000         .000       
          JUNIATA      OP     TRAN2FBA 500 KV    CB             .000         .000       
          JUNIATA      OP     TRAN_2   230 KV    CB             .000         .000       
 3490    500/230.Susquehanna.T21 (Sctnlz F)                Y Y Y S Y Y N N     NNNNNNNNNNYNNNNNNNNNYYYNN NNNNNNNNNNYNNNNNNNNNYYYNN
          SUSQUEHA     OP     WESC_S   500 KV    CB             .000         .000      P
          SUSQUEHA     OP     TR_BK_21 230 KV    CB             .000         .000      P
          SUSQUEHA     X      21       500 KV                   .000         .000      P
          SUSQUEHA     OP     SUNB_2-S 500 KV    CB             .000         .000      P
          SUSQUEHA     OP     GEN_2-S  500 KV    CB             .000         .000      P
 3500    500/230.Conastone.500-2                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONASTON     OP     500 K CB 500 KV    CB             .000         .000      P
          CONASTON     OP     2302 GCB 230 KV    CB             .000         .000      P
          CONASTON     OP     2324_GCB 230 KV    CB             .000         .000      P
          CONASTON     X      500-2    500 KV                   .000         .000      P
          CONASTON     OP     2323 2   230 KV    CB             .000         .000      P
          CONASTON     OP     500 L CB 500 KV    CB             .000         .000      P
          CONASTON     OP     2322 GCB 230 KV    CB             .000         .000      P
 3520    500/230.Conastone.500-4                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONASTON     OP     500 A CB 500 KV    CB             .000         .000      P
          CONASTON     OP     500 B CB 500 KV    CB             .000         .000      P
          CONASTON     X      500-4    500 KV                   .000         .000      P
          CONASTON     OP     3 SS TR  230 KV    CB             .000         .000      P
          CONASTON     OP     500-1TR  230 KV    CB             .000         .000      P
          CONASTON     OP     DIS500-4 230 KV    DIS            .000         .000      P
          CONASTON     OP     2323 4   230 KV    CB             .000         .000      P
          CONASTON     OP     2310CB   230 KV    CB             .000         .000      P
          CONASTON     OP     5004TRCS 500 KV    DIS            .000         .000      P
 3530    500/230.TMI.T1                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          TMI          OP     1B-12    230 KV    CB             .000         .000      P
          TMI          OP     500802   500 KV    CB             .000         .000      P
          TMI          X      1 BANK   500 KV                   .000         .000      P
          TMI          OP     1B-02    230 KV    CB             .000         .000      P
          TMI          OP     502602   500 KV    CB             .000         .000      P
 3540    500/230.Keeney.AT50                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          KEENEY       OP     237      230 KV    CB             .000         .000       
          KEENEY       OP     507      500 KV    CB             .000         .000       
          KEENEY       X      AT50     500 KV                   .000         .000       
          KEENEY       OP     236      230 KV    CB             .000         .000       
          KEENEY       OP     505      500 KV    CB             .000         .000       
 3550    500/230.Keeney.AT51                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          KEENEY       X      AT51     500 KV                   .000         .000       
          KEENEY       OP     233      230 KV    CB             .000         .000       
          KEENEY       OP     502      500 KV    CB             .000         .000       
          KEENEY       OP     234      230 KV    CB             .000         .000       
          KEENEY       OP     501      500 KV    CB             .000         .000       
 3560    L500.CalvertCliffs-ChalkPoint.5072                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          CHALKPT      OP     12BB     500 KV    CB             .000         .000       
          CALVERTC     OP     5072     500 KV    CB             .000         .000       
          CHALKPT      L      CAL-CHA  500 KV                   .000         .000       
          CHALKPT      OP     12CB     500 KV    CB             .000         .000       
          CALVERTC     OP     2GEN_72  500 KV    CB             .000         .000       
 3570    L500.CalvertCliffs-WaughChapel.5052               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          CALVERTC     L      CAL-WAU2 500 KV                   .000         .000       
          CALVERTC     OP     5052 RB  500 KV    CB             .000         .000       
          WAUGHCHA     OP     3TR_5052 500 KV    CB             .000         .000       
          CALVERTC     OP     5052 BB  500 KV    CB             .000         .000       
          WAUGHCHA     OP     5052LINE 500 KV    DIS            .000         .000       
          CALVERTC     OP     DUM 5052 500 KV    DIS            .000         .000       
          WAUGHCHA     OP     5052     500 KV    CB             .000         .000       
 3580    L500.Brighton-WaughChapel                         Y Y Y S Y Y N N     YNNNNNNNNNNYNNNNNNNNNNYYN YNNNNNNNNNNYNNNNNNNNNNYYN
          WAUGHCHA     OP     4TR_5053 500 KV    CB             .000         .000       
          WAUGHCHA     OP     5053CB   500 KV    CB             .000         .000       
          BRIGHTON     OP     5BB      500 KV    CB             .000         .000       
          BRIGHTON     OP     5AB      500 KV    CB             .000         .000       
          WAUGHCHA     L      BRI-WAU  500 KV                   .000         .000       
 3590    L500.Brighton-Conastone                           Y Y Y S Y Y N N     YNNNNYYYNNNYNNYNNNNNNNYYN YNNNNYYYNNNYNNYNNNNNNNYYN
          BRIGHTON     OP     6BB      500 KV    CB             .000         .000      P
          CONASTON     OP     500 H CB 500 KV    CB             .000         .000      P
          CONASTON     OP     5011DSW  500 KV    DIS            .000         .000      P
          CONASTON     L      BRI-CNS  500 KV                   .000         .000      P
          BRIGHTON     OP     DUM18384 500 KV    DIS            .000         .000      P
          BRIGHTON     OP     6AB      500 KV    CB             .000         .000      P
          CONASTON     OP     500 J CB 500 KV    CB             .000         .000      P
 3600    L500.Brighton-Doubs.5055                          Y Y Y S Y Y N N     YNNNNNNYNNNYNNYNNNNNNNYYN YNNNNNNYNNNYNNYNNNNNNNYYN
          DOUBS        OP     CB 51    500 KV    CB             .000         .000      P
          DOUBS        L      BRI-DOU  500 KV                   .000         .000      P
          BRIGHTON     OP     DUM18385 500 KV    DIS            .000         .000      P
          DOUBS        OP     DUM18386 500 KV    DIS            .000         .000      P
          DOUBS        OP     CB 55    500 KV    CB             .000         .000      P
          BRIGHTON     OP     7AB      500 KV    CB             .000         .000      P
          BRIGHTON     OP     7BB      500 KV    CB             .000         .000      P
 3610    L500.TMI-Hosensack.5026                           Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          HOSENSAC     L      HOS-TMI  500 KV                   .000         .000      P
          HOSENSAC     OP     TMI CB   500 KV    CB             .000         .000      P
          HOSENSAC     OP     TMISLINE 500 KV    DIS            .000         .000      P
          TMI          OP     502602   500 KV    CB             .000         .000      P
          TMI          OP     DIS 5026 500 KV    DIS            .000         .000      P
          HOSENSAC     OP     EL-TMI   500 KV    CB             .000         .000      P
          TMI          OP     502612   500 KV    CB             .000         .000      P
 3620    L500.Hunterstown-Conastone.5013                   Y Y Y S Y Y N N     YNNNNYYYNNNNNNYNYNNNNNYYN YNNNNYYYNNNNNNYNYNNNNNYYN
          CONASTON     OP     500 L CB 500 KV    CB             .000         .000       
          HUNTERST     OP     501382   500 KV    CB             .000         .000       
          HUNTERST     OP     B40      500 KV    CB             .000         .000       
          CONASTON     OP     500 M CB 500 KV    CB             .000         .000       
          CONASTON     L      CNS-HUN  500 KV                   .000         .000       
 3630    500/13/230.Limerick.T4A&T4B                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          LIMERICK     X      LIM 4A-T 13 KV                    .000         .000      P
          LIMERICK     X      LIM 4B-P 500 KV                   .000         .000      P
          LIMERICK     X      LIM 4A-S 230 KV                   .000         .000      P
          LIMERICK     OP     4A1 DIS  500 KV    DIS            .000         .000      P
          LIMERICK     OP     115 CB   500 KV    CB             .000         .000      P
          LIMERICK     X      LIM 4B-T 13 KV                    .000         .000      P
          LIMERICK     OP     315 CB   500 KV    CB             .000         .000      P
          LIMERICK     OP     525 CB   230 KV    CB             .000         .000      P
          LIMERICK     OP     4B3 DIS  230 KV    DIS            .000         .000      P
          LIMERICK     LD     20AUX    13 KV                    .000         .000      P
          LIMERICK     X      LIM 4B-S 230 KV                   .000         .000      P
          LIMERICK     OP     4B1 DIS  500 KV    DIS            .000         .000      P
          LIMERICK     X      LIM 4A-P 500 KV                   .000         .000      P
          LIMERICK     OP     4A3 DIS  230 KV    DIS            .000         .000      P
          LIMERICK     OP     625 CB   230 KV    CB             .000         .000      P
 3640    L500.Limerick-Whitpain.5030+500/230.Whitpain.500-1Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNYYN YNNNNNNNNNNNNNNYNNNNNNYYN
          WHITPAIN     OP     15 DIS   500 KV    DIS            .000         .000      P
          WHITPAIN     OP     185 CB   500 KV    CB             .000         .000      P
          WHITPAIN     X      WHT 1TR  500 KV                   .000         .000      P
          LIMERICK     OP     225 CB   500 KV    CB             .000         .000      P
          WHITPAIN     L      LIM-WHI0 500 KV                   .000         .000      P
          WHITPAIN     OP     475 CB   500 KV    CB             .000         .000      P
          LIMERICK     OP     125 CB   500 KV    CB             .000         .000      P
          WHITPAIN     OP     307 DIS  500 KV    DIS            .000         .000      P
          LIMERICK     OP     301 DIS  500 KV    DIS            .000         .000      P
          WHITPAIN     OP     115 CB   230 KV    CB             .000         .000      P
 3650    L500.Limerick-Whitpain.5031+500/230.Whitpain.500-2Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNYYN YNNNNNNNNNNNNNNYNNNNNNYYN
          WHITPAIN     OP     285 CB   500 KV    CB             .000         .000      P
          WHITPAIN     X      WHT 2TR  500 KV                   .000         .000      P
          LIMERICK     OP     235 CB   500 KV    CB             .000         .000      P
          LIMERICK     OP     311 DIS  500 KV    DIS            .000         .000      P
          WHITPAIN     OP     225 CB   230 KV    CB             .000         .000      P
          WHITPAIN     L      LIM-WHI1 500 KV                   .000         .000      P
          LIMERICK     OP     135 CB   500 KV    CB             .000         .000      P
          WHITPAIN     OP     575 CB   500 KV    CB             .000         .000      P
          WHITPAIN     OP     317 DIS  500 KV    DIS            .000         .000      P
          WHITPAIN     OP     25 DIS   500 KV    DIS            .000         .000      P
 3680    L500.Deans-Smithburg.5020                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNYYN YNNNNNNNNNNNNNNYNNNNNNYYN
          DEANS        OP     SECT 7-8 500 KV    CB             .000         .000       
          DEANS        OP     SECT 2-8 500 KV    CB             .000         .000       
          SMITHBUR     L      DEA-SMI  500 KV                   .000         .000       
          DEANS        OP     5020 DIS 500 KV    DIS            .000         .000       
          SMITHBUR     OP     BK4500DS 500 KV    DIS            .000         .000       
          SMITHBUR     OP     B5       500 KV    CB             .000         .000       
 3710    L500.Susqhnna-Wscsvl-Brngsvl.5043/5044 + Wscsvl.T3Y Y Y S Y Y N N     YNNNNNNYNNNNNNYYNNNNNNYYN YNNNNNNYNNNNNNYYNNNNNNYYN
          SUSQUEHA     OP     WESC_N   500 KV    CB             .000         .000       
          SUSQUEHA     OP     DIS 5043 500 KV    DIS            .000         .000       
          WESCOSVI     OP     TRAN3500 500 KV    CB             .000         .000       
          WESCOSVI     L      SUS-WES  500 KV                   .000         .000       
          WESCOSVI     OP     SUSQU    500 KV    DIS            .000         .000       
          SUSQUEHA     OP     WESC_S   500 KV    CB             .000         .000       
          WESCOSVI     OP     WESGIS   500 KV    CB             .000         .000       
          WESCOSVI     OP     TRAN_3   500 KV    CB             .000         .000       
 3730    L500.Salem-Orchard.5021                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNYYN YNNNNNNNNNNNNNNYNNNNNNYYN
          ORCHARD      OP     GCB A    500 KV    CB             .000         .000       
          SALEM        OP     SECT1-8  500 KV    CB             .000         .000       
          ORCHARD      OP     GCB B    500 KV    CB             .000         .000       
          SALEM        OP     DUM_ORC  500 KV    DIS            .000         .000       
          SALEM        L      ORC-SAL  500 KV                   .000         .000       
          ORCHARD      OP     G        500 KV    DIS            .000         .000       
          SALEM        OP     SECT2-8  500 KV    CB             .000         .000       
          SALEM        OP     5021 DIS 500 KV    DIS            .000         .000       
 3740    MILLSTONE STATION Units 1/2/3                     Y Y Y S Y Y N N     NNNNYNNNNNNNNNNNNNNNNNNNN NNNNYNNNNNNNNNNNNNNNNNNNN
          MILLSTON     U      GEN  2   345 KV                   .000         .000       
          MILLSTON     U      GEN  3   345 KV                   .000         .000       
          MILLSTON     U      GEN  1   345 KV                   .000         .000       
 3750    MILLSTONE STATION 1 & 3                           Y Y Y S Y Y N N     NNNNYNNNNNNNNNNNNNNNNNNNN NNNNYNNNNNNNNNNNNNNNNNNNN
          MILLSTON     U      GEN  1   345 KV                   .000         .000      P
          MILLSTON     U      GEN  3   345 KV                   .000         .000      P
 3760    CHATEAUGAY STATION TOTAL                          Y Y Y S Y Y N N     NNNNYNNNNNNNNNNNNNNNNNNNN NNNNYNNNNNNNNNNNNNNNNNNNN
          CHATEAUG     L      CHA-MAS  765 KV                   .000         .000       
          CHATEAUG     U      DC-A     765 KV                   .000         .000       
          CHATEAUG     U      AC-GEN   765 KV                   .000         .000       
          CHATEAUG     U      DC-B     765 KV                   .000         .000       
 3770    CHATEAUGAY DC TOTAL                               Y Y Y S Y Y N N     NNNNYNNNNNNNNNNNNNNNNNNNN NNNNYNNNNNNNNNNNNNNNNNNNN
          CHATEAUG     U      DC-B     765 KV                   .000         .000      P
          CHATEAUG     U      DC-A     765 KV                   .000         .000      P
 3780    PeachBottom.U2&U3                                 Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          PEACHBOT     X      P.B.3TR  500 KV                   .000         .000       
          PEACHBOT     OP     15 CB    500 KV    CB             .000         .000       
          PEACHBOT     OP     225 CB   500 KV    CB             .000         .000       
          PEACHBOT     U      UNIT02   22 KV                    .000         .000       
          PEACHBOT     X      P.B.2TR  500 KV                   .000         .000       
          PEACHBOT     OP     215 CB   500 KV    CB             .000         .000       
          PEACHBOT     U      UNIT03   22 KV                    .000         .000       
          PEACHBOT     OP     65 CB    500 KV    CB             .000         .000       
 3790    PEACH BOTTOM UNITS & 220-34                       Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          PEACHBOT     OP     345 CB   230 KV    CB             .000         .000       
          NEWLINVI     OP     260  CB  230 KV    CB             .000         .000       
          NEWLINVI     OP     273 DIS  230 KV    DIS            .000         .000       
          PEACHBOT     OP     65 CB    500 KV    CB             .000         .000       
          COCHRNVL     L      COC-NEW  230 KV                   .000         .000       
          PEACHBOT     U      UNIT03   22 KV                    .000         .000       
          PEACHBOT     OP     225 CB   500 KV    CB             .000         .000       
          PEACHBOT     OP     215 CB   500 KV    CB             .000         .000       
          PEACHBOT     OP     15 CB    500 KV    CB             .000         .000       
          COCHRNVL     L      COC-PEA  230 KV                   .000         .000       
          PEACHBOT     U      UNIT02   22 KV                    .000         .000       
 3800    PEACH BOTTOM UNITS & 220-08                       Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          NOTTINGH     OP     085      230 KV    CB             .000         .000       
          NOTTINGH     L      NOT-PEA  230 KV                   .000         .000       
          NOTTINGH     OP     087      230 KV    DIS            .000         .000       
          PEACHBOT     X      P.B.3TR  500 KV                   .000         .000       
          PEACHBOT     OP     65 CB    500 KV    CB             .000         .000       
          PEACHBOT     OP     225 CB   500 KV    CB             .000         .000       
          PEACHBOT     OP     2G3 DIS  500 KV    DIS            .000         .000       
          PEACHBOT     U      UNIT02   22 KV                    .000         .000       
          PEACHBOT     OP     3G3 DIS  500 KV    DIS            .000         .000       
          PEACHBOT     X      P.B.2TR  500 KV                   .000         .000       
          PEACHBOT     U      UNIT03   22 KV                    .000         .000       
          PEACHBOT     OP     215 CB   500 KV    CB             .000         .000       
          PEACHBOT     OP     15 CB    500 KV    CB             .000         .000       
 3810    SPS.500/13/230.PeachBottom.T1 + MuddyRun.5-8      Y Y Y S Y Y N N     YNNNNNNYNNNNNNYYNNNNNNYYN YNNNNNNYNNNNNNYYNNNNNNYYN
          PEACHBOT     X      1-S      230 KV                   .000         .000      P
          PEACHBOT     X      1-T      13 KV                    .000         .000      P
          PEACHBOT     LD     4TR      230 KV                   .000         .000      P
          MUDDYRN      L      MUD-PEA7 230 KV                   .000         .000      P
          MUDDYRN      U      UNIT7    13 KV                    .000         .000      P
          MUDDYRN      OP     075 CB   230 KV    CB             .000         .000      P
          PEACHBOT     OP     675 CB   230 KV    CB             .000         .000      P
          PEACHBOT     OP     35 CB    500 KV    CB             .000         .000      P
          PEACHBOT     OP     475      230 KV    CB             .000         .000      P
          PEACHBOT     X      1-P      500 KV                   .000         .000      P
          MUDDYRN      U      UNIT5    13 KV                    .000         .000      P
          MUDDYRN      U      UNIT6    13 KV                    .000         .000      P
          MUDDYRN      X      MR 3TR   230 KV                   .000         .000      P
          PEACHBOT     OP     175 CB   230 KV    CB             .000         .000      P
          PEACHBOT     OP     1T3 DIS  500 KV    DIS            .000         .000      P
          PEACHBOT     LD     3SU      13 KV                    .000         .000      P
          MUDDYRN      X      MR 4TR   230 KV                   .000         .000      P
          PEACHBOT     OP     45 CB    500 KV    CB             .000         .000      P
          MUDDYRN      U      UNIT8    13 KV                    .000         .000      P
 3820    L230.SteelCity-Quarry.2                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          QUARRY       OP     STCI_2   230 KV    CB             .000         .000       
          STEELCTY     OP     QUAR2    230 KV    CB             .000         .000       
          QUARRY       OP     DUMSTE   230 KV    DIS            .000         .000       
          QUARRY       OP     STCI2_E  230 KV    CB             .000         .000       
          QUARRY       L      QUA-STE2 230 KV                   .000         .000       
          QUARRY       OP     STCI2_W  230 KV    CB             .000         .000       
          STEELCTY     OP     BEP2QUA2 230 KV    CB             .000         .000       
 3840    L230.Kittatiny-Newton.T-2298                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          KITTATIN     OP     VT AC    230 KV    CB             .000         .000      P
          NEWTON       OP     BK1230DI 230 KV    DIS            .000         .000      P
          KITTATIN     OP     TK AC    230 KV    CB             .000         .000      P
          NEWTON       OP     T2298LND 230 KV    DIS            .000         .000      P
          NEWTON       L      KIT-NEW  230 KV                   .000         .000      P
          KITTATIN     OP     T2298 DI 230 KV    DIS            .000         .000      P
          NEWTON       OP     NT GC    230 KV    CB             .000         .000      P
 3870    L115.Pumphrey-Westport.110526                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PUMPHREY     OP     110526   115 KV    CB             .000         .000      P
          PUMPHREY     OP     526_534  115 KV    CB             .000         .000      P
          WESTPORT     OP     526-554  115 KV    CB             .000         .000      P
          WESTPORT     L      PUM-WES6 115 KV                   .000         .000      P
          WESTPORT     OP     13TRBBBK 34 KV     CB             .000         .000      P
          WESTPORT     OP     110526CB 115 KV    CB             .000         .000      P
          WESTPORT     X      110-10   115 KV                   .000         .000      P
          GREE BC      L      GRE-WES4 115 KV                   .000         .000      P
          WESTPORT     OP     13TRRBBK 34 KV     CB             .000         .000      P
          WESTPORT     X      110-2    115 KV                   .000         .000      P
          WESTPORT     OP     110-2BBB 34 KV     CB             .000         .000      P
          WESTPORT     OP     110-2RBB 34 KV     CB             .000         .000      P
          WESTPORT     OP     526-586  115 KV    CB             .000         .000      P
 3880    L115.Pmphry-Wstprt110524&Wstprt-Grst.110553&Wsp.U5Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PUMPHREY     L      PUM-WES4 115 KV                   .000         .000      P
          PUMPHREY     OP     524_532  115 KV    CB             .000         .000      P
          WESTPORT     OP     110-6BBB 34 KV     CB             .000         .000      P
          WESTPORT     X      110-6    115 KV                   .000         .000      P
          WESTPORT     U      CT  05   13 KV                    .000         .000      P
          PUMPHREY     OP     110524   115 KV    CB             .000         .000      P
          WESTPORT     OP     524-553  115 KV    CB             .000         .000      P
          WESTPORT     OP     110524-2 115 KV    CB             .000         .000      P
          WESTPORT     OP     110-6RBB 34 KV     CB             .000         .000      P
          WESTPORT     L      GRE-WES3 115 KV                   .000         .000      P
          WESTPORT     X      110-4    115 KV                   .000         .000      P
          WESTPORT     OP     110524-1 115 KV    CB             .000         .000      P
          WESTPORT     OP     DUMUNIT5 13 KV     DIS            .000         .000      P
 3900    L230.Brighton-Burtonsville.23013                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BURTONSV     L      BRI-BUR3 230 KV                   .000         .000      P
          BURTONSV     OP     23013B   230 KV    CB             .000         .000      P
          BRIGHTON     OP     3BB      230 KV    CB             .000         .000      P
 3910    L230.Brighton-Burtonsville.23012                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BURTONSV     OP     23012B   230 KV    CB             .000         .000      P
          BRIGHTON     L      BRI-BUR2 230 KV                   .000         .000      P
          BRIGHTON     OP     1BB      230 KV    CB             .000         .000      P
 3920    BYBERRY 138-WOODBOURNE 230 AND TRANSFORMER        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BYBERRY      X      BYB18TR  138 KV                   .000         .000      P
          WOODBOUR     X      WDB 6TR  230 KV                   .000         .000      P
          BYBERRY      L      BYB-WOO  230 KV                   .000         .000      P
          BYBERRY      X      BYB21TR  138 KV                   .000         .000      P
          BYBERRY      X      BYB 6TR  230 KV                   .000         .000      P
 3940    L115.Carroll-Taneytown-Germantown                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARROLL      OP     TANEYTOW 138 KV    CB             .000         .000      P
          TANEYTOW     L      CAR-TAN  138 KV                   .000         .000      P
          GERMANTO     OP     A3       138 KV    CB             .000         .000      P
          TANEYTOW     L      GER-TAN  138 KV                   .000         .000      P
 3950    L230.Cartanza-RedLion.23032                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          REDLION      OP     247      230 KV    CB             .000         .000      P
          CARTANZA     OP     231      230 KV    CB             .000         .000      P
          CARTANZA     L      CAR-RED  230 KV                   .000         .000      P
          CARTANZA     OP     230      230 KV    CB             .000         .000      P
          REDLION      OP     246      230 KV    CB             .000         .000      P
 3960    Center-Erdman (110555) 115 kV line                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CENTER       X      110-4    115 KV                   .000         .000      P
          CENTER       CL     BUSTIE   13 KV     CB             .000         .000      P
          CENTER       L      CEN-ERD5 115 KV                   .000         .000      P
          ERDMAN       OP     555_605  115 KV    CB             .000         .000      P
          CENTER       OP     DUM4LSBK 13 KV     CB             .000         .000      P
 3970    WSTPRT-PMPHRY(110525) 115 kV LINE                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WESTPORT     X      110-9    115 KV                   .000         .000      P
          PUMPHREY     L      PUM-WES5 115 KV                   .000         .000      P
          WESTPORT     X      110-3    115 KV                   .000         .000      P
          PUMPHREY     OP     SW110525 115 KV    CB             .000         .000      P
          WESTPORT     OP     110525   115 KV    CB             .000         .000      P
          PUMPHREY     OP     S525_2TR 115 KV    CB             .000         .000      P
          WESTPORT     OP     110-3BBB 34 KV     CB             .000         .000      P
          WESTPORT     OP     DUM9LS D 13 KV     DIS            .000         .000      P
          WESTPORT     OP     110-3RBB 34 KV     CB             .000         .000      P
 3980    Center-Erdman (110556) 115 kV line                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CENTER       X      110-1    115 KV                   .000         .000      P
          ERDMAN       OP     556_606  115 KV    CB             .000         .000      P
          CENTER       L      CEN-ERD6 115 KV                   .000         .000      P
          CENTER       OP     DUM1LSBK 13 KV     CB             .000         .000      P
          CENTER       CL     BUSTIE   13 KV     CB             .000         .000      P
          CENTER       OP     552556OC 115 KV    CB             .000         .000      P
 3990    WSTPRT-PMPHRY(110521) 115 kV LINE                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WESTPORT     OP     110-5RBB 34 KV     CB             .000         .000      P
          PUMPHREY     OP     521_535  115 KV    CB             .000         .000      P
          WESTPORT     OP     110-5BBB 34 KV     CB             .000         .000      P
          WESTPORT     X      110-5    115 KV                   .000         .000      P
          WESTPORT     OP     585-521  115 KV    CB             .000         .000      P
          PUMPHREY     OP     110521   115 KV    CB             .000         .000      P
          PUMPHREY     L      PUM-WES1 115 KV                   .000         .000      P
          WESTPORT     OP     110521CB 115 KV    CB             .000         .000      P
 4000    L230.ChalkPoint-Ryceville-Morgantown.23071/2      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MORGANTO     OP     11CB     230 KV    CB             .000         .000      P
          CHALKPT      L      CHA-RYC2 230 KV                   .000         .000      P
          CHALKPT      OP     2CB      230 KV    CB             .000         .000      P
          MORGANTO     OP     11BB     230 KV    CB             .000         .000      P
          RYCEVILL     L      MOR-RYC1 230 KV                   .000         .000      P
          CHALKPT      OP     2BB      230 KV    CB             .000         .000      P
 4010    L230.ChalkPoint-Ryceville-Morgantown.23073/4      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHALKPT      OP     1CB      230 KV    CB             .000         .000      P
          MORGANTO     OP     10CB     230 KV    CB             .000         .000      P
          CHALKPT      L      CHA-RYC4 230 KV                   .000         .000      P
          RYCEVILL     L      MOR-RYC3 230 KV                   .000         .000      P
          MORGANTO     OP     10BB     230 KV    CB             .000         .000      P
          CHALKPT      OP     1BB      230 KV    CB             .000         .000      P
 4020    L230.Chester-WestWharton.H2034                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHESTJCT     OP     H20341DI 230 KV    DIS            .000         .000      P
          CHESTJCT     OP     BK4230CS 230 KV    DIS            .000         .000      P
          WWHARTON     OP     BK2230CS 230 KV    DIS            .000         .000      P
          CHESTJCT     L      CHE-WWH  230 KV                   .000         .000      P
          WWHARTON     LD     BK 2     230 KV                   .000         .000      P
          CHESTJCT     OP     BK 4LCB  35 KV     CB             .000         .000      P
          WWHARTON     OP     EH OC    230 KV    CB             .000         .000      P
          WWHARTON     OP     H2034 DI 230 KV    DIS            .000         .000      P
          WWHARTON     OP     HA OC    230 KV    CB             .000         .000      P
          CHESTJCT     OP     LNTIECB  230 KV    CB             .000         .000      P
          CHESTJCT     X      BK 4TR   230 KV                   .000         .000      P
 4030    230/138.Chichester.9A/B                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHICHEST     OP     195CB    230 KV    CB             .000         .000      P
          CHICHEST     X      9A       230 KV                   .000         .000      P
          CHICHEST     X      9B       230 KV                   .000         .000      P
          CHICHEST     OP     795CB    138 KV    CB             .000         .000      P
 4040    Claymont-Linwood.220-84                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CLAYMONT     OP     232      230 KV    CB             .000         .000      P
          LINWDPE      OP     115      230 KV    CB             .000         .000      P
          LINWDPE      L      CLA-LIN  230 KV                   .000         .000      P
          CLAYMONT     OP     233      230 KV    CB             .000         .000      P
          LINWDPE      OP     125      230 KV    CB             .000         .000      P
 4050    Edgemoor-Linwood.22043.or.220-85                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          EDGEMOOR     OP     234      230 KV    CB             .000         .000      P
          LINWDPE      OP     125      230 KV    CB             .000         .000      P
          LINWDPE      OP     225      230 KV    CB             .000         .000      P
          EDGEMOOR     OP     233      230 KV    CB             .000         .000      P
          LINWDPE      L      EDG-LIN  230 KV                   .000         .000      P
 4060    L230.Chambers-Churchtown.2313                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          CHURCHTO     OP     BUSGCBC  230 KV    CB             .000         .000       
          CHURCHTO     L      CHA-CHU  230 KV                   .000         .000       
          CHURCHTO     OP     BUSGCBA  230 KV    CB             .000         .000       
          CHAMBERS     OP     BUSGCBC  230 KV    CB             .000         .000       
          CHAMBERS     OP     BUSGCBA  230 KV    CB             .000         .000       
 4070    L230.Chambers-Pedricktown.2312                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          CHAMBERS     L      CHA-PED  230 KV                   .000         .000      P
          CHAMBERS     OP     BUSGCBA  230 KV    CB             .000         .000      P
          PEDRICKT     OP     BUSGCBB  230 KV    CB             .000         .000      P
          CHAMBERS     OP     BUSGCBB  230 KV    CB             .000         .000      P
          PEDRICKT     OP     BUSGCBA  230 KV    CB             .000         .000      P
 4080    L230.CedarGrove-CedarSub-Roseland.Y-2277          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CEDARGRO     OP     1-5      230 KV    CB             .000         .000      P
          CEDARGRO     OP     2-5      230 KV    CB             .000         .000      P
          CEDARSUB     CL     LOADTRAN 230 KV    DIS            .000         .000      P
          ROSELAND     L      CED-ROSY 230 KV                   .000         .000      P
          CEDARGRO     L      CED-CEDY 230 KV                   .000         .000      P
          ROSELAND     OP     3-10     230 KV    CB             .000         .000      P
          ROSELAND     OP     3-13     230 KV    CB             .000         .000      P
 4090    ELIMSPORT-CLINTON 230 LINE                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          ELIMSPOR     OP     CLINTONW 230 KV    CB             .000         .000      P
          CLINTON      OP     SAEGERS  230 KV    CB             .000         .000      P
          ELIMSPOR     OP     CLINTONE 230 KV    CB             .000         .000      P
          CLINTON      L      CLI-ELI  230 KV                   .000         .000      P
          CLINTON      X      1        230 KV                   .000         .000      P
          CLINTON      OP     TRAN_1   69 KV     CB             .000         .000      P
          CLINTON      OP     TRAN1MOD 230 KV    DIS            .000         .000      P
          CLINTON      OP     ELIMLINE 230 KV    CB             .000         .000      P
 4100    Windsor-Clarksville (C-1017) 230 kV line          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WIND JC      OP     CAP1 CB  35 KV     CB             .000         .000      P
          CLARKSVI     OP     TRANT-2  230 KV    DIS            .000         .000      P
          CLARKSVI     L      CLA-WIN  230 KV                   .000         .000      P
          WIND JC      OP     FC       230 KV    CB             .000         .000      P
          CLARKSVI     CL     LOADTRAN 230 KV    DIS            .000         .000      P
          WIND JC      X      BK 1TR   230 KV                   .000         .000      P
          CLARKSVI     OP     SECT1-2  230 KV    CB             .000         .000      P
 4110    L230.Frackville-Columbia + Frackvil.T2 + Colu.T1  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          COLU PL      X      1        230 KV                   .000         .000      P
          COLU PL      OP     MONT     230 KV    CB             .000         .000      P
          FRACKVIL     OP     TRAN_2   69 KV     CB             .000         .000      P
          FRACKVIL     X      2        230 KV                   .000         .000      P
          COLU PL      OP     TRAN_1   69 KV     CB             .000         .000      P
          FRACKVIL     OP     COLU     230 KV    CB             .000         .000      P
          FRACKVIL     L      COL-FRA  230 KV                   .000         .000      P
 4120    L230.Columbia-Montour                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          COLU PL      OP     TRAN2MOD 230 KV    DIS            .000         .000       
          COLU PL      OP     TRAN_2   69 KV     CB             .000         .000       
          COLU PL      X      2        230 KV                   .000         .000       
          MONTOUR      OP     COLU     230 KV    CB             .000         .000       
          COLU PL      OP     MONT_MOD 230 KV    DIS            .000         .000       
          MONTOUR      OP     COLUSAEG 230 KV    CB             .000         .000       
          COLU PL      L      COL-MON  230 KV                   .000         .000       
          COLU PL      OP     MONT     230 KV    CB             .000         .000       
 4130    L115.GreeneStreet-ConcordStreet.110559            Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          CONC BC      OP     110-1HS  115 KV    CB             .000         .000       
          GREE BC      OP     553_59   115 KV    CB             .000         .000       
          GREE BC      OP     110-2LS  13 KV     CB             .000         .000       
          GREE BC      X      110-2    115 KV                   .000         .000       
          CONC BC      OP     TIE CB2  13 KV     CB             .000         .000       
 4140    CHICHESTER-FOULK 230 LINE                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FOULK        L      CHI-FOU  230 KV                   .000         .000      P
          FOULK        X      FOU 2TR  230 KV                   .000         .000      P
 4160    L230.Lenape-Concord.220-70                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LENAPE       X      LEN2TR   230 KV                   .000         .000       
          CONC PE      X      CON 1TR  230 KV                   .000         .000       
          LENAPE       OP     785 CB   230 KV    CB             .000         .000       
          CONC PE      OP     455 CB   230 KV    CB             .000         .000       
          CONC PE      L      CON-LEN  230 KV                   .000         .000       
 4170    L230.Middletown-Concord.220-25                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MIDD PE      OP     1TRLS CB 13 KV     CB             .000         .000      P
          CONC PE      L      CON-MID  230 KV                   .000         .000      P
          CONC PE      OP     255 CB   230 KV    CB             .000         .000      P
          MIDD PE      OP     715 CB   230 KV    DIS            .000         .000      P
          MIDD PE      OP     875 CB   230 KV    CB             .000         .000      P
          MIDD PE      OP     55 CS    230 KV    DIS            .000         .000      P
          MIDD PE      OP     257 DIS  230 KV    DIS            .000         .000      P
          MIDD PE      OP     555 CB   35 KV     CB             .000         .000      P
          MIDD PE      X      MID 5TR  230 KV                   .000         .000      P
          MIDD PE      X      MID 1TR  230 KV                   .000         .000      P
 4180    FOX CHASE-CRESCENTVILLE 138 LINE                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CRESCENT     L      CRE-FOX  138 KV                   .000         .000      P
          CRESCENT     X      CRS 2TR  138 KV                   .000         .000      P
 4190    WANEETA-CRESCENTVILLE 130-01                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CRESCENT     X      CRS 1TR  138 KV                   .000         .000      P
          WANEETA      L      CRE-WAN1 138 KV                   .000         .000      P
          CRESCENT     X      CRS 3TR  138 KV                   .000         .000      P
 4200    WANEETA-CRESCENTVILLE 130-03 & TRANS              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WANEETA      L      CRE-WAN3 138 KV                   .000         .000       
          CRESCENT     X      CRS 4TR  138 KV                   .000         .000       
 4210    L138.Cromby-Perkiomen                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROMBY       OP     320 CB   138 KV    CB             .000         .000      P
          CROMBY       L      CRO-PER  138 KV                   .000         .000      P
          PERKIOME     OP     305      138 KV    CB             .000         .000      P
          PERKIOME     OP     307 DIS  138 KV    DIS            .000         .000      P
 4220    L230.Limerick-Cromby.220-61                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          LIMERICK     OP     735 CB   230 KV    CB             .000         .000      P
          CROMBY       L      CRO-LIM1 230 KV                   .000         .000      P
          LIMERICK     OP     635 CB   230 KV    CB             .000         .000      P
          CROMBY       OP     615 CB   230 KV    CB             .000         .000      P
 4230    L230.Limerick-Cromby.220-60                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          LIMERICK     OP     715 CB   230 KV    CB             .000         .000      P
          CROMBY       L      CRO-LIM0 230 KV                   .000         .000      P
          LIMERICK     OP     515 CB   230 KV    CB             .000         .000      P
          CROMBY       OP     605 CB   230 KV    CB             .000         .000      P
 4240    L230.WestShore-Cumberland + 230/69.Cumberland.T1  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CUMB PL      X      1        230 KV                   .000         .000      P
          CUMB PL      L      CUM-WSH  230 KV                   .000         .000      P
          WSHORE       OP     CUMBERLA 230 KV    CB             .000         .000      P
          CUMB PL      OP     WSHO     230 KV    CB             .000         .000      P
          CUMB PL      OP     TRAN_1   69 KV     CB             .000         .000      P
 4250    L230.Camden-Cuthbert Blvd.U-2299                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CUTHBERT     LD     T30LD    230 KV                   .000         .000      P
          CUTHBERT     L      CAM-CUTU 230 KV                   .000         .000      P
          CUTHBERT     OP     2-4      230 KV    CB             .000         .000      P
          CAMDEN       OP     1-11     230 KV    CB             .000         .000      P
          CAMDEN       OP     11-12    230 KV    CB             .000         .000      P
          CUTHBERT     OP     2-3      230 KV    CB             .000         .000      P
 4260    L230.CuthbertBlvd-Gloucester.C-2308               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CUTHBERT     CL     T10-20   230 KV    DIS            .000         .000      P
          GLOUCEST     OP     2-4      230 KV    CB             .000         .000      P
          GLOUCEST     L      CUT-GLOC 230 KV                   .000         .000      P
          CUTHBERT     OP     2-3      230 KV    CB             .000         .000      P
          CUTHBERT     OP     T20      230 KV    CB             .000         .000      P
          CUTHBERT     OP     1-3      230 KV    CB             .000         .000      P
          GLOUCEST     OP     1-4      230 KV    CB             .000         .000      P
 4270    L230.Dauphin-Hummelstown.1097 + Dauphin.T1        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DAUPHIN      OP     JUNIHUMM 230 KV    CB             .000         .000      P
          DAUPHIN      L      DAU-HUM  230 KV                   .000         .000      P
          HUMMELST     OP     DAUP_W   230 KV    CB             .000         .000      P
          HUMMELST     OP     DAUP_E   230 KV    CB             .000         .000      P
          DAUPHIN      X      1        230 KV                   .000         .000      P
          DAUPHIN      OP     TRAN_1   69 KV     CB             .000         .000      P
          HUMMELST     OP     TRAN_1-W 69 KV     CB             .000         .000      P
 4280    L230.Dauphin-Juniata.1087 + 230/69.Dauphin.T2     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DAUPHIN      OP     TRAN_2   69 KV     CB             .000         .000      P
          DAUPHIN      OP     JUNIHUMM 230 KV    CB             .000         .000      P
          DAUPHIN      X      2        230 KV                   .000         .000      P
          JUNIATA      OP     DAUP     230 KV    CB             .000         .000      P
          DAUPHIN      L      DAU-JUN  230 KV                   .000         .000      P
 4290    L230.Deans-Westfield.W-2249                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DEANS        OP     SECT 5-6 230 KV    CB             .000         .000      P
          DEANS        L      DEA-NEW  230 KV                   .000         .000      P
          DEANS        OP     SECT 1-5 230 KV    CB             .000         .000      P
          WESTFIEL     OP     230SC1-2 230 KV    CB             .000         .000      P
          NEWDOVER     L      NEW-WES  230 KV                   .000         .000      P
          WESTFIEL     OP     T-1 DIS  230 KV    DIS            .000         .000      P
          NEWDOVER     OP     TRAN20   230 KV    DIS            .000         .000      P
          NEWDOVER     OP     W22491-2 230 KV    DIS            .000         .000      P
          NEWDOVER     OP     W-2249   230 KV    DIS            .000         .000      P
          WESTFIEL     OP     W-2249   230 KV    DIS            .000         .000      P
 4300    L230.Brunswick-Deans.D-2204                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRUNSWIC     OP     SEC15-16 230 KV    CB             .000         .000       
          DEANS        OP     SECT9-10 230 KV    CB             .000         .000       
          BRUNSWIC     OP     3-15     230 KV    CB             .000         .000       
          DEANS        OP     SECT 1-9 230 KV    CB             .000         .000       
          DEANS        L      BRU-DEA  230 KV                   .000         .000       
 4310    L230.Dickerson-QuinceOrchard.23033                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DICKERSO     L      DIC-QUI3 230 KV                   .000         .000      P
          QUINCEOR     OP     23033B   230 KV    CB             .000         .000      P
          DICKERSO     OP     3BB      230 KV    CB             .000         .000      P
          DICKERSO     OP     3AB      230 KV    CB             .000         .000      P
 4320    L230.DickersonH-QuinceOrchard.23032               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DICKERSH     OP     45B      230 KV    CB             .000         .000      P
          DICKERSH     OP     45C      230 KV    CB             .000         .000      P
          DICKERSH     L      DIC-QUI2 230 KV                   .000         .000      P
          QUINCEOR     OP     23032B   230 KV    CB             .000         .000      P
 4330    GARRETT TRANS 1 138-115 XF                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PENNMAR      OP     GENDUMMY 22 KV     CB             .000         .000       
          GARRETAP     L      GAR-PEN  115 KV                   .000         .000       
          GARRETAP     L      DEE-GAR  115 KV                   .000         .000       
          GARRETAP     L      GAR-GAR  115 KV                   .000         .000       
          GARRETT      OP     T2 CB    138 KV    CB             .000         .000       
          PENNMAR      OP     LOAD BKR 22 KV     CB             .000         .000       
          DEEPCRK      OP     2GEN115  115 KV    CB             .000         .000       
          DEEPCRK      OP     LOAD BKR 12 KV     CB             .000         .000       
          PENNMAR      OP     ROCKWOSF 115 KV    CB             .000         .000       
          DEEPCRK      OP     1GEN115  115 KV    CB             .000         .000       
 4340    L230.Dickerson-QuinceOrchard.23035                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DICKERSO     OP     4AB      230 KV    CB             .000         .000       
          DICKERSO     L      DIC-QUI5 230 KV                   .000         .000       
          DICKERSO     OP     4BB      230 KV    CB             .000         .000       
          QUINCEOR     OP     23035B   230 KV    CB             .000         .000       
 4350    L230.AlabamaAvenue-BuzzardPoint.23027             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BUZZARD      OP     13TSBCB  138 KV    CB             .000         .000      P
          BUZZARD      P      13T-PS   138 KV                   .000         .000      P
          BUZZARD      X      STAB-13  230 KV                   .000         .000      P
          ALABAMA      OP     4TS4B    13 KV     CB             .000         .000      P
          ALABAMA      X      4T       230 KV                   .000         .000      P
          BUZZARD      CP     B-027    230 KV                   .000         .000      P
          ALABAMA      OP     4BB      230 KV    CB             .000         .000      P
          ALABAMA      OP     4TS3B    13 KV     CB             .000         .000      P
          BUZZARD      L      ALA-BUZ7 230 KV                   .000         .000      P
 4360    L230.AlabamaAvenue-PalmersCorner.23088            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ALABAMA      X      3T       230 KV                   .000         .000       
          ALABAMA      OP     3BB      230 KV    CB             .000         .000       
          PALMERS      OP     23088B   230 KV    CB             .000         .000       
          ALABAMA      L      ALA-PAL  230 KV                   .000         .000       
          ALABAMA      OP     3TS5B    13 KV     CB             .000         .000       
          ALABAMA      OP     6B       230 KV    CB             .000         .000       
          ALABAMA      CP     136-2R   230 KV                   .000         .000       
          ALABAMA      OP     3TS4B    13 KV     CB             .000         .000       
 4370    L230.AlabamaAvenue-BuzzardPoint.23026             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ALABAMA      OP     2TS2B    13 KV     CB             .000         .000       
          ALABAMA      OP     2TS1B    13 KV     CB             .000         .000       
          BUZZARD      CP     B-026    230 KV                   .000         .000       
          BUZZARD      OP     8TSBCB   138 KV    CB             .000         .000       
          BUZZARD      X      STAB-8T  230 KV                   .000         .000       
          ALABAMA      X      2T       230 KV                   .000         .000       
          ALABAMA      OP     2BB      230 KV    CB             .000         .000       
          BUZZARD      L      ALA-BUZ6 230 KV                   .000         .000       
          BUZZARD      P      8T-PS    138 KV                   .000         .000       
 4380    L230.AlabamaAvenue-PalmersCorner.23089            Y Y Y S Y Y N N     YNNNNNNNNNNYNNNNNNNNNNNYN YNNNNNNNNNNYNNNNNNNNNNNYN
          ALABAMA      CP     136-1R   230 KV                   .000         .000       
          ALABAMA      L      ALA-PAL9 230 KV                   .000         .000       
          ALABAMA      OP     1TS6B    13 KV     CB             .000         .000       
          ALABAMA      OP     1TS1B    13 KV     CB             .000         .000       
          ALABAMA      OP     23089L   230 KV    DIS            .000         .000       
          ALABAMA      OP     1BB      230 KV    CB             .000         .000       
          PALMERS      OP     23089B   230 KV    CB             .000         .000       
          ALABAMA      X      1T       230 KV                   .000         .000       
          ALABAMA      OP     5B       230 KV    CB             .000         .000       
 4390    L230.BearRock-Johnstown                           Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNYYN YNNYNNNNNNNNNNNNNNNNNNYYN
          JOHNSTOW     L      BEA-JOH  230 KV                   .000         .000      P
          JOHNSTOW     OP     B7       230 KV    CB             .000         .000      P
          BEARROCK     OP     B1       230 KV    CB             .000         .000      P
          BEARROCK     OP     B2       230 KV    CB             .000         .000      P
 4400    L230.BearRock-Johnstown + Seneca.1.Pump           Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          JOHNSTOW     L      BEA-JOH  230 KV                   .000         .000      P
          SENECA       U      1GEN     13 KV                    .000         .000      P
          JOHNSTOW     OP     B7       230 KV    CB             .000         .000      P
          BEARROCK     OP     B2       230 KV    CB             .000         .000      P
          BEARROCK     OP     B1       230 KV    CB             .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
 4410    L230.BearRock-Johnstown + Seneca.2.Pump           Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          BEARROCK     OP     B2       230 KV    CB             .000         .000       
          JOHNSTOW     OP     B7       230 KV    CB             .000         .000       
          BEARROCK     OP     B1       230 KV    CB             .000         .000       
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000       
          SENECA       X      NO2 230  230 KV                   .000         .000       
          JOHNSTOW     L      BEA-JOH  230 KV                   .000         .000       
          SENECA       U      2GEN     13 KV                    .000         .000       
 4420    L230.BearRock-Johnstown + Seneca.1&2.Pump         Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       U      1GEN     13 KV                    .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
          BEARROCK     OP     B1       230 KV    CB             .000         .000      P
          JOHNSTOW     L      BEA-JOH  230 KV                   .000         .000      P
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          BEARROCK     OP     B2       230 KV    CB             .000         .000      P
          JOHNSTOW     OP     B7       230 KV    CB             .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
          SENECA       X      NO2 230  230 KV                   .000         .000      P
 4430    L230.Altoona-BearRock                             Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNYYN YNNYNNNNNNNNNNNNNNNNNNYYN
          ALTOONA      OP     B30      230 KV    CB             .000         .000      P
          BEARROCK     OP     B3       230 KV    CB             .000         .000      P
          BEARROCK     OP     B1       230 KV    CB             .000         .000      P
          ALTOONA      L      ALT-BEA  230 KV                   .000         .000      P
          ALTOONA      OP     B27      230 KV    CB             .000         .000      P
 4440    L230.Altoona-BearRock + Seneca.1.Pump             Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       U      1GEN     13 KV                    .000         .000      P
          ALTOONA      L      ALT-BEA  230 KV                   .000         .000      P
          BEARROCK     OP     B3       230 KV    CB             .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          ALTOONA      OP     B27      230 KV    CB             .000         .000      P
          BEARROCK     OP     B1       230 KV    CB             .000         .000      P
          ALTOONA      OP     B30      230 KV    CB             .000         .000      P
 4450    L230.Altoona-BearRock + Seneca.2.Pump             Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          ALTOONA      OP     B30      230 KV    CB             .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
          BEARROCK     OP     B3       230 KV    CB             .000         .000      P
          ALTOONA      L      ALT-BEA  230 KV                   .000         .000      P
          ALTOONA      OP     B27      230 KV    CB             .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
          BEARROCK     OP     B1       230 KV    CB             .000         .000      P
          SENECA       X      NO2 230  230 KV                   .000         .000      P
 4460    L230.Altoona-BearRock + Seneca.1&2.Pump           Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          SENECA       U      1GEN     13 KV                    .000         .000      P
          ALTOONA      L      ALT-BEA  230 KV                   .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
          SENECA       X      NO2 230  230 KV                   .000         .000      P
          BEARROCK     OP     B3       230 KV    CB             .000         .000      P
          BEARROCK     OP     B1       230 KV    CB             .000         .000      P
          ALTOONA      OP     B30      230 KV    CB             .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
          ALTOONA      OP     B27      230 KV    CB             .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
 4470    L230.Altoona-Raystown.2001                        Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNNYN YNNYNNNNNNNNNNNNNNNNNNNYN
          ALTOONA      L      ALT-RAY  230 KV                   .000         .000      P
          ALTOONA      OP     B10      230 KV    CB             .000         .000      P
          RAYSTOWN     OP     B1       230 KV    CB             .000         .000      P
          ALTOONA      OP     B24      230 KV    CB             .000         .000      P
 4490    L69.ATCO-Tabernacle.0783                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ATCO         L      ATC-TAB  69 KV                    .000         .000      P
          ATCO         OP     OCB P    69 KV     CB             .000         .000      P
          TABERNAC     OP     OCB B    69 KV     CB             .000         .000      P
 4500    L69.ATCO-Tansboro.0707                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TANSBORO     OP     OCB B    69 KV     CB             .000         .000      P
          ATCO         OP     OCB A    69 KV     CB             .000         .000      P
          ATCO         L      ATC-TAN  69 KV                    .000         .000      P
 4510    230/138.Athenia.220-1                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ATHENIA      X      220-1    230 KV                   .000         .000      P
          ATHENIA      OP     220-1LS  138 KV    CB             .000         .000      P
          ATHENIA      OP     220-1CB  230 KV    CB             .000         .000      P
 4520    L230.Athenia-Belleville.Z-2226                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BELLEVIL     LD     26KV     230 KV                   .000         .000      P
          ATHENIA      OP     1-5      230 KV    CB             .000         .000      P
          ATHENIA      OP     3-5      230 KV    CB             .000         .000      P
          BELLEVIL     OP     SECT 1-2 230 KV    CB             .000         .000      P
          ATHENIA      L      ATH-BEL  230 KV                   .000         .000      P
 4530    L230.Athenia-Saddlebrook.Q-2217                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SADDLEBR     CP     RCTR     230 KV                   .000         .000      P
          ATHENIA      OP     4-8      230 KV    CB             .000         .000      P
          ATHENIA      L      ATH-SAD  230 KV                   .000         .000      P
          SADDLEBR     OP     1-6      230 KV    CB             .000         .000      P
          SADDLEBR     OP     5-6      230 KV    CB             .000         .000      P
          ATHENIA      OP     2-8      230 KV    CB             .000         .000      P
 4540    L138.Fairlawn-KullerRoad.L-1364                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FAIRLAWN     OP     SECT 1-6 138 KV    CB             .000         .000      P
          KULLERRD     L      FAI-KUL  138 KV                   .000         .000      P
          FAIRLAWN     CL     23TRANSF 26 KV     DIS            .000         .000      P
          KULLERRD     CL     LOADTRAN 138 KV    DIS            .000         .000      P
          KULLERRD     OP     SECT 1-3 138 KV    CB             .000         .000      P
          FAIRLAWN     OP     132-3    138 KV    DIS            .000         .000      P
          KULLERRD     OP     TRAN T-1 138 KV    DIS            .000         .000      P
 4550    Athenia-Kuller Road (J-1362) 138 kV line          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KULLERRD     OP     SECT 1-3 138 KV    CB             .000         .000      P
          KULLERRD     OP     TRAN T-2 138 KV    DIS            .000         .000      P
          KULLERRD     CL     LOADTRAN 138 KV    DIS            .000         .000      P
          ATHENIA      L      ATH-KUL  138 KV                   .000         .000      P
          ATHENIA      OP     SECT 2-3 138 KV    CB             .000         .000      P
          ATHENIA      OP     SECT 1-2 138 KV    CB             .000         .000      P
 4560    L138.Fairlawn-Athenia.I-1361                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ATHENIA      OP     I-1361   138 KV    DIS            .000         .000      P
          FAIRLAWN     OP     SECT 1-2 138 KV    CB             .000         .000      P
          ATHENIA      OP     1-5      138 KV    CB             .000         .000      P
          ATHENIA      OP     GREATFAL 26 KV     DIS            .000         .000      P
          ATHENIA      OP     3-8CB    138 KV    CB             .000         .000      P
          ATHENIA      OP     132-3 SF 138 KV    DIS            .000         .000      P
          ATHENIA      OP     5-6      138 KV    CB             .000         .000      P
          ATHENIA      L      ATH-FAI  138 KV                   .000         .000      P
          FAIRLAWN     OP     132-1    138 KV    DIS            .000         .000      P
          ATHENIA      X      132-3    138 KV                   .000         .000      P
 4570    L230.Bala-Parrish.220-20                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BALA         L      BAL-PAR  230 KV                   .000         .000      P
          BALA         X      BALA4TR  230 KV                   .000         .000      P
          PARRISH      X      PAR 1TR  230 KV                   .000         .000      P
 4580    PLYMOUTH MEETING-BALA 230 LINE                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BALA         L      BAL-PLY  230 KV                   .000         .000      P
          PLYMOUTH     OP     185 CB   230 KV    CB             .000         .000      P
          BALA         OP     250 CB   230 KV    CB             .000         .000      P
          BALA         X      BALA6TR  230 KV                   .000         .000      P
          BALA         OP     6TRLS CB 13 KV     CB             .000         .000      P
          BALA         OP     265 DIS  230 KV    CB             .000         .000      P
 4590    PLYMOUTH MEETING-BARBADOS 230 LINE                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BARBADOS     X      BARB 9   230 KV                   .000         .000      P
          BARBADOS     L      BAR-PLY  230 KV                   .000         .000      P
 4600    Marion-Bayonne (L-1338) 138 kV line               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BAYONNE      OP     SECT 1-2 138 KV    CB             .000         .000      P
          MARION       OP     132-2    138 KV    DIS            .000         .000      P
          BAYONNE      OP     132-1    138 KV    DIS            .000         .000      P
          BAYONNE      L      BAY-MAR  138 KV                   .000         .000      P
          MARION       CL     23TRANSF 138 KV    DIS            .000         .000      P
          MARION       OP     SECT 3-4 138 KV    CB             .000         .000      P
          MARION       OP     SECT 1-4 138 KV    CB             .000         .000      P
          BAYONNE      X      132-1 TR 138 KV                   .000         .000      P
 4610    LINDEN-BAYWAY (Z-1352) 138 LINE                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BAYWAY       L      BAY-LINZ 138 KV                   .000         .000      P
          LINDEN       OP     Z-1352   138 KV    CB             .000         .000      P
          BAYWAY       OP     SECT 1-2 138 KV    CB             .000         .000      P
          BAYWAY       OP     Z-1352   138 KV    DIS            .000         .000      P
          LINDEN       OP     ZTRNSFBU 138 KV    DIS            .000         .000      P
 4620    L230.BvrBrk-Glcstr.I-2235 + 230/26.Glcstr.220-3   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BEAVERBR     CL     LOADTRAN 230 KV    DIS            .000         .000       
          BEAVERBR     L      BEA-GLO  230 KV                   .000         .000       
          GLOUCEST     OP     I-2235   230 KV    DIS            .000         .000       
          BEAVERBR     OP     SECT 1-2 230 KV    CB             .000         .000       
          GLOUCEST     OP     220-3CB  230 KV    CB             .000         .000       
          GLOUCEST     X      220-3 TR 230 KV                   .000         .000       
          BEAVERBR     OP     TRAN  2  230 KV    DIS            .000         .000       
          GLOUCEST     OP     1-9CB    230 KV    CB             .000         .000       
          BEAVERBR     OP     I-2235   230 KV    DIS            .000         .000       
          GLOUCEST     OP     2-9CB    230 KV    CB             .000         .000       
 4630    L230.NewFreedom-BeaverBrook.K-2237                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BEAVERBR     OP     K-2237   230 KV    DIS            .000         .000      P
          NEWFREED     OP     230 2-8  230 KV    CB             .000         .000      P
          BEAVERBR     CL     LOADTRAN 230 KV    DIS            .000         .000      P
          NEWFREED     OP     230 7-8  230 KV    CB             .000         .000      P
          BEAVERBR     CL     TRAN  1  230 KV    DIS            .000         .000      P
          NEWFREED     L      BEA-NEW  230 KV                   .000         .000      P
          BEAVERBR     OP     SECT 1-2 230 KV    CB             .000         .000      P
 4640    L230.Bergen-Leonia.T-2272                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BERGEN       OP     T 2272   230 KV    DIS            .000         .000      P
          LEONIA       OP     SECT 1-2 230 KV    CB             .000         .000      P
          BERGEN       OP     3-13     230 KV    CB             .000         .000      P
          BERGEN       L      BER-LEO  230 KV                   .000         .000      P
          LEONIA       OP     T2272DIS 230 KV    DIS            .000         .000      P
          BERGEN       OP     13-14    230 KV    CB             .000         .000      P
 4650    L138.Fairlawn-Bergen.M-1339                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BERGEN       OP     1-6      138 KV    CB             .000         .000      P
          BERGEN       OP     SECT 1-2 138 KV    CB             .000         .000      P
          FAIRLAWN     OP     SECT 1-4 138 KV    CB             .000         .000      P
          BERGEN       L      BER-FAIM 138 KV                   .000         .000      P
          FAIRLAWN     OP     M-1339-3 138 KV    DIS            .000         .000      P
          BERGEN       OP     M-1339-1 138 KV    DIS            .000         .000      P
          BERGEN       OP     M-1339   138 KV    CB             .000         .000      P
          FAIRLAWN     OP     132-2    138 KV    DIS            .000         .000      P
 4660    L230.Berks-Lauschtown+230/69.Berks.T2             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BERKS        OP     LAUSSREA 230 KV    CB             .000         .000      P
          BERKS        OP     LAUSSLEB 230 KV    CB             .000         .000      P
          BERKS        X      2        230 KV                   .000         .000      P
          LAUSCHTO     OP     BERKS3_E 230 KV    CB             .000         .000      P
          BERKS        OP     TRAN_2   69 KV     CB             .000         .000      P
          LAUSCHTO     L      BER-LAU  230 KV                   .000         .000      P
          LAUSCHTO     OP     BERKS3_W 230 KV    CB             .000         .000      P
 4670    BYBERRY-BLUEGRASS 138 LINE                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BLUEGRAS     X      BLU 6TR  138 KV                   .000         .000      P
          BLUEGRAS     L      BLU-BYB  138 KV                   .000         .000      P
          BYBERRY      X      BYB19TR  138 KV                   .000         .000      P
          BLUEGRAS     X      BLU 3TR  138 KV                   .000         .000      P
 4680    HOLMSBURG-BLUEGRASS 138 LINE                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOLMESBU     OP     11TRLSCB 13 KV     CB             .000         .000      P
          HOLMESBU     X      HOL11TR  138 KV                   .000         .000      P
          HOLMESBU     OP     705 CB   138 KV    CB             .000         .000      P
          BLUEGRAS     L      BLU-HOL  138 KV                   .000         .000      P
          BLUEGRAS     OP     165 CB   138 KV    CB             .000         .000      P
 4690    L230.Bushkill-BloomingGrove + BloomingGrove.T1    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BLOOMING     X      1        230 KV                   .000         .000      P
          BLOOMING     OP     TRAN_1   69 KV     CB             .000         .000      P
          BUSHKILL     OP     BLGR     230 KV    CB             .000         .000      P
          BLOOMING     OP     PAUPBUSH 230 KV    CB             .000         .000      P
          BLOOMING     L      BLO-BUS  230 KV                   .000         .000      P
 4700    NEWLINVILLE-BRADFORD 220-32                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          NEWLINVI     X      NEW 2TR  230 KV                   .000         .000      P
          BRADFORD     L      BRA-NEW2 230 KV                   .000         .000      P
 4710    NEWLINVILLE-BRADFORD 220-33                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          BRADFORD     OP     15 CB    230 KV    CB             .000         .000      P
          BRADFORD     L      BRA-NEW3 230 KV                   .000         .000      P
          BRADFORD     OP     280 CB   230 KV    CB             .000         .000      P
          NEWLINVI     OP     230 CB   230 KV    CB             .000         .000      P
 4720    PLANEBROOK-BRADFORD 230 LINE                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          BRADFORD     L      BRA-PLA1 230 KV                   .000         .000      P
          PLANEBRO     OP     315 CB   230 KV    CB             .000         .000      P
          BRADFORD     OP     290 CB   230 KV    CB             .000         .000      P
          BRADFORD     OP     25 CB    230 KV    CB             .000         .000      P
 4730    L230.Bridgeport-Mickleton.2315                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MICKLETO     OP     BV       230 KV    CB             .000         .000      P
          BRIDGEPO     OP     BUSGCBB  230 KV    CB             .000         .000      P
          MICKLETO     OP     DIS KM   230 KV    DIS            .000         .000      P
          BRIDGEPO     L      BRI-MIC  230 KV                   .000         .000      P
          MICKLETO     OP     ES       230 KV    CB             .000         .000      P
          BRIDGEPO     OP     BUSGCBA  230 KV    CB             .000         .000      P
 4740    L230.Bridgewater-Somerville.O-2215                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SOMERVIL     OP     SECT1-2  230 KV    CB             .000         .000      P
          SOMERVIL     CL     LOADTRAN 230 KV    DIS            .000         .000      P
          BRIDGEWA     OP     5-6      230 KV    CB             .000         .000      P
          BRIDGEWA     L      BRI-SOM  230 KV                   .000         .000      P
          SOMERVIL     OP     TRANT-1  230 KV    DIS            .000         .000      P
          BRIDGEWA     OP     O-2215   230 KV    DIS            .000         .000      P
          BRIDGEWA     OP     2-6      230 KV    CB             .000         .000      P
 4760    L230.BrandonShores-Wagner.2346                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WAGNER       X      230-1    230 KV                   .000         .000      P
          WAGNER       OP     35-2_3   115 KV    CB             .000         .000      P
          BRANDONS     OP     1TR_P2TR 230 KV    CB             .000         .000      P
          BRANDONS     OP     2346CB   230 KV    CB             .000         .000      P
          WAGNER       OP     34-1OCB  115 KV    CB             .000         .000      P
          WAGNER       OP     32-3OCB  115 KV    CB             .000         .000      P
          WAGNER       OP     110533CB 115 KV    CB             .000         .000      P
          BRANDONS     L      BRA-WAG1 230 KV                   .000         .000      P
 4770    L230.BrandonShores-Wagner.2347                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRANDONS     OP     23472344 230 KV    CB             .000         .000      P
          WAGNER       OP     110402   115 KV    CB             .000         .000      P
          WAGNER       OP     35-2_4   115 KV    CB             .000         .000      P
          BRANDONS     OP     2347CB   230 KV    CB             .000         .000      P
          WAGNER       OP     110401   115 KV    CB             .000         .000      P
          WAGNER       OP     110403   115 KV    CB             .000         .000      P
          WAGNER       X      230-2    230 KV                   .000         .000      P
          BRANDONS     L      BRA-WAG2 230 KV                   .000         .000      P
 4780    L230.BrunnerIsland-WestShore1&2 + WShore.T2       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRUNNERI     OP     WSHO_E   230 KV    CB             .000         .000      P
          BRUNNERI     OP     WSHO_W   230 KV    CB             .000         .000      P
          WSHORE       OP     TRAN2MOD 230 KV    DIS            .000         .000      P
          WSHORE       OP     BRIS1    230 KV    CB             .000         .000      P
          WSHORE       X      2        230 KV                   .000         .000      P
          BRUNNERI     L      BRU-WSH1 230 KV                   .000         .000      P
          WSHORE       OP     TRAN_2   69 KV     CB             .000         .000      P
 4790    L230.Yorkana-BrunnerIsland + Yorkana.T1           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRUNNERI     OP     YORKWEST 230 KV    CB             .000         .000      P
          YORKANA      OP     B14      230 KV    CB             .000         .000      P
          BRUNNERI     OP     YORK     230 KV    CB             .000         .000      P
          YORKANA      OP     B11      230 KV    CB             .000         .000      P
          YORKANA      X      BANK 1   230 KV                   .000         .000      P
          YORKANA      OP     1B82     115 KV    CB             .000         .000      P
          BRUNNERI     L      BRU-YOR  230 KV                   .000         .000      P
          YORKANA      OP     A27      230 KV    DIS            .000         .000      P
 4810    L230.DickersonH-Doubs.23102/203                   Y Y Y S Y Y N N     YNNNNNNNNNNYNNNNNNNNNNNYN YNNNNNNNNNNYNNNNNNNNNNNYN
          DICKERSH     OP     412A     230 KV    CB             .000         .000      P
          DOUBS        L      DIC-DOU2 230 KV                   .000         .000      P
          DOUBS        OP     DJ5 CB   230 KV    CB             .000         .000      P
          DOUBS        OP     DJ6 CB   230 KV    CB             .000         .000      P
 4820    L230.Branchburg-EastFlemington.I-2209             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EFLEMING     X      BK 4TR   230 KV                   .000         .000      P
          EFLEMING     OP     QI GC    230 KV    CB             .000         .000      P
          EFLEMING     L      BRA-EFL  230 KV                   .000         .000      P
          BRANCHBU     OP     SECT 1-3 230 KV    CB             .000         .000      P
          EFLEMING     OP     BK4230CS 230 KV    DIS            .000         .000      P
          EFLEMING     OP     I2209 DI 230 KV    DIS            .000         .000      P
          BRANCHBU     OP     I-2209   230 KV    DIS            .000         .000      P
          BRANCHBU     OP     SECT 3-4 230 KV    CB             .000         .000      P
 4830    L230.PleasantValley-EastFlemington.Q-2243         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PLVY PS      OP     SECT1-2  230 KV    CB             .000         .000      P
          EFLEMING     OP     BK3230CS 230 KV    DIS            .000         .000      P
          EFLEMING     OP     QI GC    230 KV    CB             .000         .000      P
          EFLEMING     X      BK 3TR   230 KV                   .000         .000      P
          EFLEMING     L      EFL-PLV  230 KV                   .000         .000      P
 4840    L230.Siegfried-E.Palmrt + 230/69.Sgfrd.T3&EPlmt.T1Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          SIEGFRIE     OP     TRAN_3-E 69 KV     CB             .000         .000      P
          EPALMERT     OP     TRAN_1   69 KV     CB             .000         .000      P
          EPALMERT     OP     TRAN1MOD 230 KV    DIS            .000         .000      P
          EPALMERT     L      EPA-SIE  230 KV                   .000         .000      P
          SIEGFRIE     X      3        230 KV                   .000         .000      P
          EPALMERT     OP     HARWSIE3 230 KV    CB             .000         .000      P
          EPALMERT     X      1        230 KV                   .000         .000      P
          EPALMERT     OP     SIEG_3   230 KV    CB             .000         .000      P
          SIEGFRIE     OP     TRAN_3-W 69 KV     CB             .000         .000      P
 4850    L138.Athenia-EastRutherford.S-1345                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ATHENIA      OP     1-4CB    138 KV    CB             .000         .000      P
          ERUTHERF     OP     132-2    138 KV    DIS            .000         .000      P
          ATHENIA      X      132-4    138 KV                   .000         .000      P
          ATHENIA      OP     132-4SF  138 KV    CB             .000         .000      P
          ERUTHERF     X      132-2TR  138 KV                   .000         .000      P
          ERUTHERF     OP     SECT 1-2 138 KV    CB             .000         .000      P
          ERUTHERF     L      ATH-ERU  138 KV                   .000         .000      P
          ATHENIA      OP     S-1345   138 KV    DIS            .000         .000      P
          ERUTHERF     OP     132-1    138 KV    DIS            .000         .000      P
 4860    L138.Bergen-EastRutherford.R-1344                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ERUTHERF     OP     TRAN T10 138 KV    DIS            .000         .000      P
          BERGEN       OP     R-1344   138 KV    DIS            .000         .000      P
          ERUTHERF     OP     R-1344   138 KV    DIS            .000         .000      P
          BERGEN       OP     R_1344   138 KV    CB             .000         .000      P
          ERUTHERF     OP     SECT 1-2 138 KV    CB             .000         .000      P
          ERUTHERF     OP     132-1    138 KV    DIS            .000         .000      P
          ERUTHERF     L      BER-ERU  138 KV                   .000         .000      P
 4870    L115.EastSayre-EastTowanda.1056                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ESAYRE       L      ESA-ETO  115 KV                   .000         .000      P
          ESAYRE       OP     ETOWANDA 115 KV    CB             .000         .000      P
          ETOWANDA     OP     E SAYRSF 115 KV    CB             .000         .000      P
 4880    L230.EaglePoint-Thorofare.O-2241                  Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          EAGLEPT      OP     100      230 KV    CB             .000         .000      P
          EAGLEPT      OP     102      230 KV    CB             .000         .000      P
          EAGLEPT      OP     O-2241   230 KV    DIS            .000         .000      P
          THOROFAR     OP     O-2241-3 230 KV    DIS            .000         .000      P
          THOROFAR     OP     O-W      230 KV    CB             .000         .000      P
          THOROFAR     OP     TRANT-2  230 KV    CB             .000         .000      P
          THOROFAR     CL     LOADTRAN 230 KV    DIS            .000         .000      P
          EAGLEPT      L      EAG-THOO 230 KV                   .000         .000      P
 4890    L230.EaglePoint-Gloucester.P-2242                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GLOUCEST     OP     1-3      230 KV    CB             .000         .000      P
          EAGLEPT      L      EAG-GLO  230 KV                   .000         .000      P
          GLOUCEST     OP     2-3      230 KV    CB             .000         .000      P
          GLOUCEST     OP     P-2242   230 KV    DIS            .000         .000      P
          EAGLEPT      OP     100      230 KV    CB             .000         .000      P
          EAGLEPT      OP     P-2242   230 KV    DIS            .000         .000      P
          EAGLEPT      OP     101      230 KV    CB             .000         .000      P
 4900    L230.Eddington-Holmesburg-Richmond.220-56         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDDINGTO     L      EDD-HOLT 230 KV                   .000         .000      P
          HOLMETAP     L      HOLT-RIC 230 KV                   .000         .000      P
          HOLMESBU     L      HOL-HOLT 230 KV                   .000         .000      P
          RICH PE      OP     475 CB   230 KV    CB             .000         .000      P
          RICH PE      OP     575 CB   230 KV    CB             .000         .000      P
          EDDINGTO     OP     4TRLS CB 13 KV     CB             .000         .000      P
          EDDINGTO     X      EDNG4TR  230 KV                   .000         .000      P
          EDDINGTO     OP     125 CB   230 KV    CB             .000         .000      P
          HOLMESBU     OP     565      230 KV    CB             .000         .000      P
 4910    CHICHESTER-EDDYSTONE 230 LINE                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHICHEST     OP     365 CB   230 KV    CB             .000         .000       
          EDDYSTON     OP     365 CB   230 KV    CB             .000         .000       
          EDDYSTON     L      CHI-EDD  230 KV                   .000         .000       
 4920    Claymont-Edgemoor.23015                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          EDGEMOOR     OP     231      230 KV    CB             .000         .000      P
          CLAYMONT     OP     231      230 KV    CB             .000         .000      P
          EDGEMOOR     L      CLA-EDG  230 KV                   .000         .000      P
          CLAYMONT     OP     235      230 KV    CB             .000         .000      P
          EDGEMOOR     OP     230      230 KV    CB             .000         .000      P
 4930    230/138.Edgemoor.AT20                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDGEMOOR     OP     231      230 KV    CB             .000         .000      P
          EDGEMOOR     OP     3-6      138 KV    CB             .000         .000      P
          EDGEMOOR     X      AT20     230 KV                   .000         .000      P
          EDGEMOOR     OP     232      230 KV    CB             .000         .000      P
          EDGEMOOR     OP     3-5      138 KV    CB             .000         .000      P
 4940    L230.Edgemoor-Harmony.23012                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARMONY      OP     234      230 KV    CB             .000         .000       
          EDGEMOOR     OP     236      230 KV    CB             .000         .000       
          EDGEMOOR     OP     237      230 KV    CB             .000         .000       
          HARMONY      OP     233      230 KV    CB             .000         .000       
          EDGEMOOR     L      EDG-HAR  230 KV                   .000         .000       
 4950    NW SCOTT-EDIC 345 LINE                            Y Y Y S Y Y N N     YNNNYNNNNNNNNNNNNNNNNNNYN YNNNYNNNNNNNNNNNNNNNNNNYN
          EDIC_PTR     L      EDI-NEW  345 KV                   .000         .000       
 4960    L138.Devilsbrook-Plainsboro-Trenton.D1330         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TRENTON      L      PLA-TRE  138 KV                   .000         .000       
          PLAINSBU     L      DEV-PLA  138 KV                   .000         .000       
          PLAINSBU     OP     D13303-4 138 KV    DIS            .000         .000       
          PLAINSBU     OP     TRAN T-2 138 KV    DIS            .000         .000       
          TRENTON      OP     SECT1-2  138 KV    CB             .000         .000       
          PLAINSBU     CL     LOADTRAN 138 KV    DIS            .000         .000       
          DEVILSBR     OP     TRAN T-1 138 KV    CB             .000         .000       
          DEVILSBR     OP     SECT 1-2 138 KV    DIS            .000         .000       
          TRENTON      OP     SECT2-3  138 KV    CB             .000         .000       
          PLAINSBU     OP     D13301-2 138 KV    DIS            .000         .000       
          PLAINSBU     OP     D13302-3 138 KV    DIS            .000         .000       
          DEVILSBR     CL     LOADXFER 138 KV    DIS            .000         .000       
 4970    230/138.Brunswick.220-6                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRUNSWIC     OP     220-6CB  138 KV    CB             .000         .000       
          BRUNSWIC     OP     SEC15-16 230 KV    CB             .000         .000       
          BRUNSWIC     X      220-6    230 KV                   .000         .000       
          BRUNSWIC     OP     220-6DIS 230 KV    DIS            .000         .000       
          BRUNSWIC     OP     SEC4-16  230 KV    CB             .000         .000       
 4980    Edison-MeadowRoad-Metuchen (Q-1317) 138 kV Line   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDISON       U      UNIT12   13 KV                    .000         .000       
          MEADOWRD     L      MEA-METQ 138 KV                   .000         .000       
          EDISON       U      UNIT14   13 KV                    .000         .000       
          EDISON       U      UNIT13   13 KV                    .000         .000       
          MEADOWRD     CL     LOADTRAN 138 KV    DIS            .000         .000       
          EDISON       L      EDI-MEAQ 138 KV                   .000         .000       
          EDISON       X      NO 1GSU  138 KV                   .000         .000       
          MEADOWRD     OP     TRAN T-1 138 KV    DIS            .000         .000       
          METUCHEN     OP     Q-1317   138 KV    CB             .000         .000       
          EDISON       OP     SECT 1-2 138 KV    CB             .000         .000       
          EDISON       U      UNIT11   13 KV                    .000         .000       
 4990    Brunswick-Edison-Meadow Rd-Metuchn (H-1360/R-1318)Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDISON       X      NO 2GSU  138 KV                   .000         .000       
          MEADOWRD     OP     TRAN T-2 138 KV    DIS            .000         .000       
          MEADOWRD     L      MEA-METR 138 KV                   .000         .000       
          EDISON       L      EDI-MEAR 138 KV                   .000         .000       
          EDISON       OP     SECT 1-3 138 KV    CB             .000         .000       
          EDISON       U      UNIT21   13 KV                    .000         .000       
          EDISON       U      UNIT23   13 KV                    .000         .000       
          BRUNSWIC     OP     H-1360   138 KV    CB             .000         .000       
          MEADOWRD     OP     R13182-3 138 KV    DIS            .000         .000       
          BRUNSWIC     L      BRU-EDI  138 KV                   .000         .000       
          MEADOWRD     OP     R13181-2 138 KV    DIS            .000         .000       
          METUCHEN     OP     R-1318   138 KV    CB             .000         .000       
          MEADOWRD     CL     LOADTRAN 138 KV    DIS            .000         .000       
          EDISON       U      UNIT24   13 KV                    .000         .000       
          EDISON       OP     R-1318-3 138 KV    DIS            .000         .000       
          EDISON       OP     H-1360   138 KV    DIS            .000         .000       
          EDISON       U      UNIT22   13 KV                    .000         .000       
 5010    L230.Elimsport-Lycoming.2 + 230/69.Lycoming.2     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          ELIMSPOR     L      ELI-LYC2 230 KV                   .000         .000       
          LYCOMING     X      2        230 KV                   .000         .000       
          ELIMSPOR     OP     LYCOM2E  230 KV    CB             .000         .000       
          ELIMSPOR     OP     LYCOM2W  230 KV    CB             .000         .000       
          LYCOMING     OP     TRAN_2   69 KV     CB             .000         .000       
 5020    230/115.Forest.T1 (Sctnlz F)                      Y Y Y S Y Y N N     NNNYNNNNNNYNNNNNNNNNYYYNN NNNYNNNNNNYNNNNNNNNNYYYNN
          FOREST       OP     GLADE    230 KV    CB             .000         .000       
          FOREST       OP     B11      230 KV    CB             .000         .000       
          FOREST       X      1 TX     230 KV                   .000         .000       
          FOREST       OP     1TX115   115 KV    CB             .000         .000       
 5030    230/115.Forest.T1 (Sctnlz F) + Relay.Warren       Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          FOREST       L      FOR-GLA1 230 KV                   .000         .000       
          FOREST       L      FOR-SQU  230 KV                   .000         .000       
          WARREN       OP     B32      115 KV    CB             .000         .000       
          WARREN       L      FAL-WAR  115 KV                   .000         .000       
          FOREST       L      FOR-RID  115 KV                   .000         .000       
          FOREST       OP     GLADE    230 KV    CB             .000         .000       
          FOREST       OP     B11      230 KV    CB             .000         .000       
          FOREST       OP     1TX115   115 KV    CB             .000         .000       
          FOREST       X      1 TX     230 KV                   .000         .000       
 5040    230/115.Forest.T1 (Scntlz F) + Seneca.2.Pump      Y Y Y S Y Y N N     NNNYNNNNNNYNNNNNNNNNNNNNN NNNYNNNNNNYNNNNNNNNNNNNNN
          FOREST       OP     1TX115   115 KV    CB             .000         .000       
          FOREST       OP     B11      230 KV    CB             .000         .000       
          FOREST       X      1 TX     230 KV                   .000         .000       
          FOREST       L      FOR-RID  115 KV                   .000         .000       
          FOREST       L      FOR-SQU  230 KV                   .000         .000       
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000       
          FOREST       L      FOR-GLA1 230 KV                   .000         .000       
          SENECA       U      2GEN     13 KV                    .000         .000       
 5050    230/115.Forest.T1 (Scntlz F) + Seneca.1&2.Pump    Y Y Y S Y Y N N     NNNYNNNNNNYNNNNNNNNNNNNNN NNNYNNNNNNYNNNNNNNNNNNNNN
          FOREST       X      1 TX     230 KV                   .000         .000       
          FOREST       OP     1TX115   115 KV    CB             .000         .000       
          SENECA       U      2GEN     13 KV                    .000         .000       
          SENECA       U      1GEN     13 KV                    .000         .000       
          FOREST       L      FOR-GLA1 230 KV                   .000         .000       
          FOREST       OP     B11      230 KV    CB             .000         .000       
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000       
          FOREST       L      FOR-RID  115 KV                   .000         .000       
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000       
          FOREST       L      FOR-SQU  230 KV                   .000         .000       
 5060    230/115.Forest.T1 (Scntlz F) + Seneca.1.Pump      Y Y Y S Y Y N N     NNNYNNNNNNYNNNNNNNNNNNNNN NNNYNNNNNNYNNNNNNNNNNNNNN
          FOREST       OP     1TX115   115 KV    CB             .000         .000       
          FOREST       L      FOR-RID  115 KV                   .000         .000       
          FOREST       L      FOR-GLA1 230 KV                   .000         .000       
          FOREST       L      FOR-SQU  230 KV                   .000         .000       
          FOREST       X      1 TX     230 KV                   .000         .000       
          FOREST       OP     B11      230 KV    CB             .000         .000       
          SENECA       U      1GEN     13 KV                    .000         .000       
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000       
 5070    L230.Elko-Shawville                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ELKO         L      ELK-SHA  230 KV                   .000         .000       
          SHAWVILL     OP     ELKO230  230 KV    CB             .000         .000       
          ELKO         OP     SHAWVILL 230 KV    CB             .000         .000       
 5080    500/138.Elroy.1TR+138/69.Elroy.2TR                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ELROYPL      L      ELR-ELR  500 KV                   .000         .000       
          ELROYPL      OP     TRAN1DIS 138 KV    CB             .000         .000       
          ELROYPL      X      1 TR     500 KV                   .000         .000       
          ELROYPL      X      2 TR     138 KV                   .000         .000       
          ELROYPL      OP     TRAN2    69 KV     CB             .000         .000       
          ELROYPL      OP     TRAN1MOD 500 KV    DIS            .000         .000       
          ELROY        OP     13       500 KV    DIS            .000         .000       
          ELROYPL      OP     TRAN2DIS 138 KV    CB             .000         .000       
          ELROYPL      OP     TRAN1    500 KV    CB             .000         .000       
 5090    230/138.Emilie.8TR                                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EMILIE       OP     885      230 KV    CB             .000         .000       
          EMILIE       X      EMIL8TR  230 KV                   .000         .000       
          EMILIE       OP     180 CB   138 KV    CB             .000         .000       
 5100    230/138.Emilie.7TR                                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EMILIE       OP     175 CB   138 KV    CB             .000         .000       
          EMILIE       X      EMIL7TR  230 KV                   .000         .000       
          EMILIE       OP     775 CB   230 KV    CB             .000         .000       
 5110    WINDY EDGE-HAZEL-ERDMAN 110506                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ERDMAN       L      ERD-HAZ6 115 KV                   .000         .000      P
          HAZELWOO     L      HAZ-WIN6 115 KV                   .000         .000      P
          ERDMAN       X      110-1    115 KV                   .000         .000      P
 5120    L115.WindyEdge-Hazelwood-Erdman.110505            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ERDMAN       X      110-2    115 KV                   .000         .000      P
          ERDMAN       L      ERD-HAZ5 115 KV                   .000         .000      P
          HAZELWOO     L      HAZ-WIN5 115 KV                   .000         .000      P
 5130    L345.ErieSouth-ErieWest.3001                      Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNYYN YNNYNNNNNNNNNNNNNNNNNNYYN
          ERIEW        OP     B9       345 KV    CB             .000         .000      P
          ERIES        OP     128 B2   345 KV    CB             .000         .000      P
          ERIES        X      5 TX  3  345 KV                   .000         .000      P
          ERIES        X      NO8 TX   345 KV                   .000         .000      P
          ERIEW        L      ERI-ERI  345 KV                   .000         .000      P
          ERIES        OP     128 B1   345 KV    CB             .000         .000      P
          ERIEW        OP     B8       345 KV    CB             .000         .000      P
 5140    L345.ErieSouth-ErieWest.3001 + Seneca.1.Pump      Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       X      NO1 230  230 KV                   .000         .000      P
          ERIES        X      NO8 TX   345 KV                   .000         .000      P
          SENECA       U      1GEN     13 KV                    .000         .000      P
          ERIES        OP     128 B2   345 KV    CB             .000         .000      P
          ERIES        X      5 TX  3  345 KV                   .000         .000      P
          ERIEW        L      ERI-ERI  345 KV                   .000         .000      P
          ERIEW        OP     B9       345 KV    CB             .000         .000      P
          ERIEW        OP     B8       345 KV    CB             .000         .000      P
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          ERIES        OP     128 B1   345 KV    CB             .000         .000      P
 5150    L345.ErieSouth-ErieWest.3001 + Seneca.1&2.Pump    Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          SENECA       U      1GEN     13 KV                    .000         .000      P
          ERIES        OP     128 B2   345 KV    CB             .000         .000      P
          ERIEW        OP     B9       345 KV    CB             .000         .000      P
          ERIES        OP     128 B1   345 KV    CB             .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
          ERIEW        L      ERI-ERI  345 KV                   .000         .000      P
          ERIEW        OP     B8       345 KV    CB             .000         .000      P
          ERIES        X      5 TX  3  345 KV                   .000         .000      P
          ERIES        X      NO8 TX   345 KV                   .000         .000      P
          SENECA       X      NO2 230  230 KV                   .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
 5160    L345.ErieSouth-ErieWest.3001 + Seneca.2.Pump      Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       X      NO2 230  230 KV                   .000         .000       
          ERIES        X      NO8 TX   345 KV                   .000         .000       
          ERIES        X      5 TX  3  345 KV                   .000         .000       
          ERIEW        L      ERI-ERI  345 KV                   .000         .000       
          ERIEW        OP     B9       345 KV    CB             .000         .000       
          ERIES        OP     128 B2   345 KV    CB             .000         .000       
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000       
          ERIES        OP     128 B1   345 KV    CB             .000         .000       
          SENECA       U      2GEN     13 KV                    .000         .000       
          ERIEW        OP     B8       345 KV    CB             .000         .000       
 5170    L138.Foundry-Newark.K-1337                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FOUNDRY      OP     SECT 1-2 138 KV    CB             .000         .000       
          NEWARK       OP     132-2 CB 13 KV     CB             .000         .000       
          NEWARK       OP     132-2    138 KV    DIS            .000         .000       
          NEWARK       X      132-2-P  138 KV                   .000         .000       
          NEWARK       OP     132-2 CB 26 KV     CB             .000         .000       
          NEWARK       X      132-2-T  13 KV                    .000         .000       
          FOUNDRY      OP     TRAN T-1 138 KV    DIS            .000         .000       
          FOUNDRY      CL     LOADTRAN 138 KV    DIS            .000         .000       
          NEWARK       OP     SECT 2-5 138 KV    CB             .000         .000       
          NEWARK       X      132-2-S  26 KV                    .000         .000       
          FOUNDRY      L      FOU-NEW  138 KV                   .000         .000       
 5180    L115.FaceRock-FiveForks.110901-1&2                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FACEROCK     OP     FIFO_1   115 KV    DIS            .000         .000      P
          FIVEFORK     L      FAC-FIV1 115 KV                   .000         .000      P
          FACEROCK     OP     FIFO_2   115 KV    DIS            .000         .000      P
          FACEROCK     L      FAC-FIV2 115 KV                   .000         .000      P
          FIVEFORK     OP     110KVTIE 115 KV    CB             .000         .000      P
 5190    L230.Fairlawn-Waldwick.O-2267 + Fairlawn.220-1    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FAIRLAWN     L      FAI-WAL  230 KV                   .000         .000      P
          WALDWICK     OP     SECT3-4  230 KV    CB             .000         .000      P
          FAIRLAWN     X      220-1    230 KV                   .000         .000      P
          WALDWICK     OP     SECT2-4  230 KV    CB             .000         .000      P
          FAIRLAWN     OP     2201 LSD 138 KV    CB             .000         .000      P
          WALDWICK     P      2267PAR  230 KV                   .000         .000      P
 5200    L115.Warren-Falconer.1086 [NYISO]                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WARREN       OP     B32      115 KV    CB             .000         .000       
          FALCONER     L      FAL-WAR  115 KV                   .000         .000       
          FALCONER     OP     R121     115 KV    CB             .000         .000       
 5210    EMILIE-FALLS 138 LINE                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FALLS        X      FALL1TR  138 KV                   .000         .000      P
          FALLS        OP     215 CB   138 KV    CB             .000         .000      P
          FALLS        L      EMI-FAL  138 KV                   .000         .000      P
          FALLS        OP     10 CB    35 KV     CB             .000         .000      P
 5220    STEEL TAP-FALLS 138 LINE                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FALLS        L      FAL-STE  138 KV                   .000         .000      P
          FALLS        X      FALL2TR  138 KV                   .000         .000      P
          FALLS        OP     223 DIS  138 KV    DIS            .000         .000      P
          FALLS        OP     267 DIS  138 KV    DIS            .000         .000      P
          FALLS        OP     20 CB    35 KV     CB             .000         .000      P
          FALLS        OP     215 CB   138 KV    CB             .000         .000      P
          STEELTAP     OP     30       138 KV    CB             .000         .000      P
          STEELTAP     OP     64       138 KV    DIS            .000         .000      P
          STEELTAP     OP     60       138 KV    CB             .000         .000      P
 5230    L345.Hudson-Farragut.B-3402                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HUDSON       OP     1-9      230 KV    CB             .000         .000      P
          HUDSON       X      345-1    345 KV                   .000         .000      P
          FARRAGUT     OP     CB 22    345 KV    CB             .000         .000      P
          HUDSON       OP     9-10     230 KV    CB             .000         .000      P
          HUDSON       L      FAR-HUDB 345 KV                   .000         .000      P
 5240    L345.Farragut-Marion.C-3403                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MARION       L      FAR-MAR  345 KV                   .000         .000      P
          MARION       OP     3-4      345 KV    CB             .000         .000      P
          MARION       OP     1-3      345 KV    CB             .000         .000      P
          FARRAGUT     OP     CB 18    345 KV    CB             .000         .000      P
 5250    BLUEGRASS-FOX CHASE 138 LINE                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FOXCHASE     OP     333 DIS  138 KV    CB             .000         .000      P
          FOXCHASE     L      BLU-FOX  138 KV                   .000         .000      P
          BLUEGRAS     OP     335 CB   138 KV    CB             .000         .000      P
 5260    L345.Gilboa-Fraser                                Y Y Y S Y Y N N     YNNNYNNNNNNNNNNNNNNNNNNYN YNNNYNNNNNNNNNNNNNNNNNNYN
          FRASER       L      FRA-GIL  345 KV                   .000         .000      P
 5270    L230.Atlantic-Freneau.H1022                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FRENEAU      OP     B23      230 KV    CB             .000         .000      P
          ATLANTIC     OP     B11      230 KV    CB             .000         .000      P
          FRENEAU      OP     B3       230 KV    CB             .000         .000      P
          FRENEAU      L      ATL-FRE  230 KV                   .000         .000      P
          FRENEAU      LD     LBK 4    230 KV                   .000         .000      P
          ATLANTIC     OP     B48      230 KV    CB             .000         .000      P
          ATLANTIC     OP     H1022 DI 230 KV    DIS            .000         .000      P
          FRENEAU      LD     BK 2     230 KV                   .000         .000      P
 5290    L230.Gilbert-GlenGardner.V-1036                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GLENGARD     OP     V1036LND 230 KV    DIS            .000         .000      P
          GLENGARD     OP     B21      230 KV    CB             .000         .000      P
          GLENGARD     OP     B2       230 KV    CB             .000         .000      P
          GILBERT      OP     V1036 DI 230 KV    DIS            .000         .000      P
          GILBERT      OP     VC OC    230 KV    CB             .000         .000      P
          GILBERT      L      GIL-GLE  230 KV                   .000         .000      P
          GILBERT      OP     PV OC    230 KV    CB             .000         .000      P
 5300    L230.Gilbert-Springfield                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GILBERT      OP     A13 OC   230 KV    CB             .000         .000      P
          SPRNGFLD     OP     GILB_E   230 KV    CB             .000         .000      P
          GILBERT      L      GIL-SPR  230 KV                   .000         .000      P
          SPRNGFLD     OP     GILB_W   230 KV    CB             .000         .000      P
          GILBERT      OP     B8       230 KV    CB             .000         .000      P
 5310    L345.Gilboa-New Scotland                          Y Y Y S Y Y N N     YNNNYNNNNNNNNNNNNNNNNNNYN YNNNYNNNNNNNNNNNNNNNNNNYN
          GILBOA       L      GIL-NEW  345 KV                   .000         .000      P
 5320    L69.Monroe-Glassboro-Rowan.0729                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROWAN        L      GLA-ROW  69 KV                    .000         .000      P
          ROWAN        OP     GCB D    69 KV     CB             .000         .000      P
          MONR AE      OP     OCB Y    69 KV     CB             .000         .000      P
          GLASSBOR     OP     ABS J    69 KV     CB             .000         .000      P
          GLASSBOR     LD     BUS3     69 KV                    .000         .000      P
          GLASSBOR     OP     ABS-K    69 KV     DIS            .000         .000      P
          GLASSBOR     LD     BUS5     69 KV                    .000         .000      P
          GLASSBOR     L      GLA-MON  69 KV                    .000         .000      P
          GLASSBOR     LD     BUS2     69 KV                    .000         .000      P
          ROWAN        OP     GCB C    69 KV     CB             .000         .000      P
 5330    L345/230.Linden-Goethals.A-2253                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LINDEN       OP     9-10     230 KV    CB             .000         .000      P
          LINDEN       OP     2-10     230 KV    CB             .000         .000      P
          GOETHALS     P      345SD01  345 KV                   .000         .000      P
          GOETHALS     OP     5        345 KV    CB             .000         .000      P
          GOETHALS     L      GOE-LIN  230 KV                   .000         .000      P
          GOETHALS     OP     7        345 KV    CB             .000         .000      P
          GOETHALS     X      1-P      345 KV                   .000         .000      P
 5340    L115.Tiffany-LaurelLake-Goudey [NYISO]            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TIFFANY      OP     LB1      115 KV    DIS            .000         .000      P
          GOUDEY       L      GOU-LAU  115 KV                   .000         .000      P
          GOUDEY       OP     95202    115 KV    CB             .000         .000      P
          LAURELL      LD     T X1     34.5 KV                  .000         .000      P
          LAURELL      L      LAU-TIF  115 KV                   .000         .000      P
 5350    L230.Conastone-Graceton.2323                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GRACETON     OP     2323 ABS 230 KV    DIS            .000         .000      P
          CONASTON     OP     2323ABS  230 KV    DIS            .000         .000      P
          GRACETON     L      CNS-GRA  230 KV                   .000         .000      P
          CONASTON     OP     2323 4   230 KV    CB             .000         .000      P
          GRACETON     OP     2323-1B  230 KV    CB             .000         .000      P
          CONASTON     OP     2323 2   230 KV    CB             .000         .000      P
          GRACETON     OP     2323-2B  230 KV    CB             .000         .000      P
 5360    L138.GrandPoint-Lttrknny-Grn-Roxbury + Roxbury.T2 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GRANDPT      L      GRA-LET  138 KV                   .000         .000      P
          ROXBURY      X      NO2 TX   138 KV                   .000         .000      P
          GREENTAP     OP     DUM2     138 KV    DIS            .000         .000      P
          GRANDPT      OP     LETTERKE 138 KV    CB             .000         .000      P
          GREENTAP     OP     DUM3     138 KV    DIS            .000         .000      P
          GREE APS     OP     T1 DIS   138 KV    DIS            .000         .000      P
          ROXBURY      OP     GRAND PT 115 KV    CB             .000         .000      P
          GREENTAP     OP     DUM1     138 KV    DIS            .000         .000      P
          ROXBURY      L      GRE-ROX  138 KV                   .000         .000      P
 5370    L230.Northwest-Granite.2311                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NRTHWES2     OP     2371-11  230 KV    CB             .000         .000      P
          NRTHWES2     OP     5TR-11   230 KV    CB             .000         .000      P
          GRANITE      OP     2311_12  230 KV    CB             .000         .000      P
          GRANITE      L      GRA-NOR1 230 KV                   .000         .000      P
 5380    L230.Northwest-Granite.2326 + 230/115.Granite.2   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NRTHWES2     OP     4TR-26   230 KV    CB             .000         .000      P
          NRTHWES2     OP     2370-26  230 KV    CB             .000         .000      P
          GRANITE      OP     2326_32  230 KV    CB             .000         .000      P
          GRANITE      OP     110528-B 115 KV    CB             .000         .000      P
          GRANITE      L      GRA-NOR6 230 KV                   .000         .000      P
          GRANITE      L      GRA-HOW3 230 KV                   .000         .000      P
          GRANITE      OP     110561-A 115 KV    CB             .000         .000      P
          GRANITE      X      230-2    230 KV                   .000         .000      P
 5390    L230.WestWharton-Greystone.E1045                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WWHARTON     OP     EH OC    230 KV    CB             .000         .000      P
          WWHARTON     OP     CE GCB   230 KV    CB             .000         .000      P
          GREYSTON     L      GRE-WWH  230 KV                   .000         .000      P
          GREYSTON     OP     E1045 GC 230 KV    CB             .000         .000      P
 5400    West Wharton #3 230/115 kV transformer            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WWHARTON     OP     BK1230CS 230 KV    DIS            .000         .000      P
          WWHARTON     OP     31C      230 KV    CB             .000         .000      P
          WWHARTON     X      BK 3     230 KV                   .000         .000      P
          WWHARTON     OP     BK3A CB  115 KV    CB             .000         .000      P
          WWHARTON     OP     BK3B CB  115 KV    CB             .000         .000      P
          WWHARTON     OP     1A3 GCB  230 KV    CB             .000         .000      P
 5410    West Wharton 230 kV capacitor                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WWHARTON     OP     CAP5CB   230 KV    CB             .000         .000      P
          WWHARTON     CP     CAP6     230 KV                   .000         .000      P
 5420    230/138.Harmony.AT20                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARMONY      OP     230      230 KV    CB             .000         .000      P
          HARMONY      X      AT20     230 KV                   .000         .000      P
          HARMONY      OP     130      138 KV    CB             .000         .000      P
          HARMONY      OP     131      138 KV    CB             .000         .000      P
          HARMONY      OP     232      230 KV    CB             .000         .000      P
 5430    L230.Harwood-Siegfried                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          HARWOOD      OP     SIEG     230 KV    CB             .000         .000      P
          HARWOOD      L      HAR-SIE  230 KV                   .000         .000      P
          SIEGFRIE     OP     HARW     230 KV    CB             .000         .000      P
          HARWOOD      OP     SIEG-T1  230 KV    CB             .000         .000      P
 5440    L230.E.Palmerton-Harwood + 230/69.Harwood.T6      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          EPALMERT     X      2        230 KV                   .000         .000      P
          EPALMERT     OP     TRAN_2   69 KV     CB             .000         .000      P
          HARWOOD      OP     TRAN6MOD 230 KV    DIS            .000         .000      P
          EPALMERT     L      EPA-HAR  230 KV                   .000         .000      P
          HARWOOD      OP     EPAL_S   230 KV    CB             .000         .000      P
          EPALMERT     OP     HARWSIE3 230 KV    CB             .000         .000      P
          HARWOOD      X      6        230 KV                   .000         .000      P
          HARWOOD      OP     TRAN_6   69 KV     CB             .000         .000      P
          HARWOOD      OP     EPAL_N   230 KV    CB             .000         .000      P
 5450    L230.Harwood-Susquehanna.1 + 230/69.Harwood.T5    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          HARWOOD      OP     EPAL_N   230 KV    CB             .000         .000      P
          SUSQUEHA     OP     SUNB1HAR 230 KV    CB             .000         .000      P
          SUSQUEHA     OP     HARW     230 KV    CB             .000         .000      P
          HARWOOD      X      5        230 KV                   .000         .000      P
          HARWOOD      OP     SIEG-T1  230 KV    CB             .000         .000      P
          HARWOOD      L      HAR-SUS  230 KV                   .000         .000      P
          HARWOOD      OP     TRAN_5   69 KV     CB             .000         .000      P
 5460    L230.Hawthorne-Waldwick.E-2257                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WALDWICK     OP     SECT2-9  230 KV    CB             .000         .000      P
          WALDWICK     P      2257PAR  230 KV                   .000         .000      P
          HAWTHORN     L      HAW-WAL  230 KV                   .000         .000      P
          WALDWICK     OP     SECT1-9  230 KV    CB             .000         .000      P
          WALDWICK     CL     LOADTRAN 230 KV    DIS            .000         .000      P
          WALDWICK     OP     TRANT-10 230 KV    DIS            .000         .000      P
          HAWTHORN     LD     T-20     230 KV                   .000         .000      P
          HAWTHORN     OP     SECT 1-2 230 KV    CB             .000         .000      P
 5470    HEATON-PERKIOMEN 138KV LINE                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HEATON       L      HEA-PER  138 KV                   .000         .000      P
          PERKIOME     OP     315      138 KV    CB             .000         .000      P
          HEATON       OP     315 CB   138 KV    CB             .000         .000      P
 5480    HEATON HEA 9TR 230-138 TRANSFORMER                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HEATON       OP     995 CB   138 KV    CB             .000         .000      P
          HEATON       L      HEA-WOO  230 KV                   .000         .000      P
          HEATON       X      HEA 9TR  230 KV                   .000         .000      P
          HEATON       OP     805 CB   230 KV    CB             .000         .000      P
          WOODBOUR     OP     905 CB   230 KV    CB             .000         .000      P
          WOODBOUR     X      WDB 5TR  230 KV                   .000         .000      P
          WOODBOUR     OP     555 CB   35 KV     CB             .000         .000      P
 5490    WHITPAIN-JARRET 230 LINE AND TRANSFORMER 1        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JARRET       X      JARRET1  230 KV                   .000         .000      P
          JARRET       L      JAR-WHI  230 KV                   .000         .000      P
 5500    WOODBOURNE-HEATON                                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WOODBOUR     X      WDB 5TR  230 KV                   .000         .000       
          HEATON       X      HEA 9TR  230 KV                   .000         .000       
          HEATON       L      HEA-WOO  230 KV                   .000         .000       
 5510    L230.HomerCity-Seward.2011                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          HOMERCIT     L      HOM-SEW  230 KV                   .000         .000      P
          HOMERCIT     OP     204      230 KV    CB             .000         .000      P
          SEWARD       OP     B-3      230 KV    CB             .000         .000      P
          HOMERCIT     OP     205      230 KV    CB             .000         .000      P
          SEWARD       OP     B4       230 KV    CB             .000         .000      P
 5520    345/230.HomerCity.AT-N                            Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNYYN YNNYNNNNNNNNNNNNNNNNNNYYN
          HOMERCIT     OP     XFNLDTER 23 KV     CB             .000         .000       
          HOMERCIT     X      N.AUTO-P 345 KV                   .000         .000       
          HOMERCIT     OP     210      230 KV    CB             .000         .000       
          HOMERCIT     OP     307      345 KV    CB             .000         .000       
          HOMERCIT     X      N.AUTO-S 230 KV                   .000         .000       
          HOMERCIT     OP     301      345 KV    CB             .000         .000       
          HOMERCIT     X      N.AUTO-T 23 KV                    .000         .000       
          HOMERCIT     OP     304      345 KV    CB             .000         .000       
 5530    345/230.HomerCity.AT-N + SPS.HomerCity.3          Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          HOMERCIT     X      N.AUTO-P 345 KV                   .000         .000       
          HOMERCIT     OP     307      345 KV    CB             .000         .000       
          HOMERCIT     X      N.AUTO-T 23 KV                    .000         .000       
          HOMERCIT     OP     210      230 KV    CB             .000         .000       
          HOMERCIT     OP     305      345 KV    CB             .000         .000       
          HOMERCIT     OP     301      345 KV    CB             .000         .000       
          HOMERCIT     X      N.AUTO-S 230 KV                   .000         .000       
          HOMERCIT     OP     XFSLDTER 23 KV     CB             .000         .000       
          HOMERCIT     OP     306      345 KV    CB             .000         .000       
          HOMERCIT     OP     304      345 KV    CB             .000         .000       
          HOMERCIT     U      UNIT 3   24 KV                    .000         .000       
 5540    345/230.HomerCity.AT-N + Relay.Warren             Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          HOMERCIT     OP     304      345 KV    CB             .000         .000      P
          HOMERCIT     X      N.AUTO-P 345 KV                   .000         .000      P
          HOMERCIT     OP     XFNLDTER 23 KV     CB             .000         .000      P
          HOMERCIT     CL     307      345 KV    CB             .000         .000      P
          HOMERCIT     OP     301      345 KV    CB             .000         .000      P
          WARREN       OP     B32      115 KV    CB             .000         .000      P
          HOMERCIT     X      N.AUTO-S 230 KV                   .000         .000      P
          HOMERCIT     X      N.AUTO-T 23 KV                    .000         .000      P
          WARREN       L      FAL-WAR  115 KV                   .000         .000      P
          HOMERCIT     OP     210      230 KV    CB             .000         .000      P
 5550    345/230.HomerCity.AT-S                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOMERCIT     X      S.AUTO-P 345 KV                   .000         .000      P
          HOMERCIT     OP     211      230 KV    CB             .000         .000      P
          HOMERCIT     OP     308      345 KV    CB             .000         .000      P
          HOMERCIT     X      S.AUTO-S 230 KV                   .000         .000      P
          HOMERCIT     LD     DUM2     23 KV                    .000         .000      P
          HOMERCIT     OP     306      345 KV    CB             .000         .000      P
          HOMERCIT     X      S.AUTO-T 23 KV                    .000         .000      P
          HOMERCIT     OP     303      345 KV    CB             .000         .000      P
 5560    345/230.HomerCity.AT-S + SPS.HomerCity.3          Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          HOMERCIT     X      S.AUTO-S 230 KV                   .000         .000      P
          HOMERCIT     OP     308      345 KV    CB             .000         .000      P
          HOMERCIT     OP     305      345 KV    CB             .000         .000      P
          HOMERCIT     OP     303      345 KV    CB             .000         .000      P
          HOMERCIT     X      NO.3 34  345 KV                   .000         .000      P
          HOMERCIT     LD     DUM2     23 KV                    .000         .000      P
          HOMERCIT     X      S.AUTO-T 23 KV                    .000         .000      P
          HOMERCIT     X      S.AUTO-P 345 KV                   .000         .000      P
          HOMERCIT     OP     211      230 KV    CB             .000         .000      P
          HOMERCIT     OP     306      345 KV    CB             .000         .000      P
          HOMERCIT     U      UNIT 3   24 KV                    .000         .000      P
 5570    L230.HomerCity-Quemahoning-Hooversville.2024      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          HOOVERSV     X      3 TX  1  230 KV                   .000         .000      P
          QUEMAHON     LD     TWO      230 KV                   .000         .000      P
          HOOVERSV     OP     NO3TX115 115 KV    CB             .000         .000      P
          HOMERCIT     OP     208      230 KV    CB             .000         .000      P
          QUEMAHON     LD     ONE      230 KV                   .000         .000      P
          HOOVERSV     L      HOO-QUE  230 KV                   .000         .000      P
          HOMERCIT     OP     207      230 KV    CB             .000         .000      P
          QUEMAHON     L      HOM-QUE  230 KV                   .000         .000      P
 5580    L230.Alburtis-Hosensack                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOSENSME     OP     107382   230 KV    CB             .000         .000       
          ALBURTME     OP     107342   230 KV    CB             .000         .000       
          ALBURTME     L      ALB-HOS  230 KV                   .000         .000       
 5590    L230.Buxmont-Hosensack.220-10 + Buxmont.T2        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOSENSAC     L      BUX-HOS  230 KV                   .000         .000      P
          HOSENSAC     OP     BUXM_3-W 230 KV    CB             .000         .000      P
          BUXMONT      OP     WHITHOS3 230 KV    CB             .000         .000      P
          HOSENSAC     OP     BUXM_3-E 230 KV    CB             .000         .000      P
          BUXMONT      OP     TRAN_2   69 KV     CB             .000         .000      P
          BUXMONT      X      2        230 KV                   .000         .000      P
 5600    230/115.Hosensack.T4 + 230.Hosensack.BusEast      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOSENSME     OP     4TRCB    115 KV    CB             .000         .000      P
          HOSENSME     L      HOS-SPR  230 KV                   .000         .000      P
          HOSENSME     OP     107382   230 KV    CB             .000         .000      P
          HOSENSME     OP     T-82     230 KV    CB             .000         .000      P
          GLENDON      OP     91432    115 KV    CB             .000         .000      P
          HOSENSME     L      GLE-HOS  115 KV                   .000         .000      P
          HOSENSME     X      4-115    230 KV                   .000         .000      P
          HOSENSME     L      HOS-NBO  230 KV                   .000         .000      P
          HOSENSME     OP     CAPSALL  230 KV    CB             .000         .000      P
          HOSENSME     OP     100682   230 KV    CB             .000         .000      P
          HOSENSME     L      ALB-HOS  230 KV                   .000         .000      P
          HOSENSME     OP     101582-1 230 KV    CB             .000         .000      P
 5610    L230.Hosensack-Wescosville.2200 +230/69.Wscsvll.T2Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOSENSAC     OP     WESC_3-E 230 KV    CB             .000         .000      P
          HOSENSAC     OP     WESC_3-W 230 KV    CB             .000         .000      P
          HOSENSAC     L      HOS-WES  230 KV                   .000         .000      P
          WESCOSVI     X      2        230 KV                   .000         .000      P
          WESCOSVI     OP     TRAN_2LO 69 KV     CB             .000         .000      P
 5620    HighRidge-Howard-Pumphrey.2332-A                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PUMPHREY     OP     230-1 LS 115 KV    DIS            .000         .000      P
          HOWARD       L      GRA-HOW3 230 KV                   .000         .000      P
          HIGHRIDG     OP     2332A CB 230 KV    CB             .000         .000      P
          HOWARD       OP     DUM1LS   230 KV    DIS            .000         .000      P
          HOWARD       L      HIG-HOW  230 KV                   .000         .000      P
          HIGHRIDG     OP     23052332 230 KV    CB             .000         .000      P
          PUMPHREY     OP     519_1TR  115 KV    CB             .000         .000      P
          HOWARD       L      HOW-PUM  230 KV                   .000         .000      P
          HOWARD       OP     2332 ABS 230 KV    CB             .000         .000      P
          HOWARD       OP     2332     230 KV    DIS            .000         .000      P
          HOWARD       OP     2332 GCB 230 KV    CB             .000         .000      P
          HOWARD       OP     2332-B   230 KV    CB             .000         .000      P
          PUMPHREY     OP     2332BCSW 230 KV    DIS            .000         .000      P
          HOWARD       LD     LOAD 1   230 KV                   .000         .000      P
          HOWARD       OP     2332-A   230 KV    CB             .000         .000      P
          PUMPHREY     OP     230-1OCB 115 KV    CB             .000         .000      P
          PUMPHREY     X      230-1    230 KV                   .000         .000      P
 5630    L345.Hurley-Roseton                               Y Y Y S Y Y N N     YNNNYNNNNNNNNNNNNNNNNNNYN YNNNYNNNNNNNNNNNNNNNNNNYN
          ROSETON      OP     31151    345 KV    CB             .000         .000      P
          ROSETON      OP     30356    345 KV    CB             .000         .000      P
          HURLEY       L      HUR-ROS  345 KV                   .000         .000      P
 5640    230/138.IndianRiver.AT20                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          INDIANRI     OP     141      138 KV    CB             .000         .000       
          INDIANRI     OP     239      230 KV    CB             .000         .000       
          INDIANRI     X      AT-20    230 KV                   .000         .000       
          INDIANRI     OP     238      230 KV    CB             .000         .000       
 5650    230/138.IndianRiver.AT21                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          INDIANRI     OP     8020     138 KV    CB             .000         .000      P
          INDIANRI     OP     233      230 KV    CB             .000         .000      P
          INDIANRI     OP     8010     138 KV    CB             .000         .000      P
          INDIANRI     X      AT-21    230 KV                   .000         .000      P
          INDIANRI     OP     9460     230 KV    CB             .000         .000      P
 5660    IndianRiver.230.Cap                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          INDIANRI     CP     CAP2     230 KV                   .000         .000       
          INDIANRI     OP     231      230 KV    CB             .000         .000       
 5670    IndianRiver.SVC                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          INDIANRI     U      SVC      230 KV                   .000         .000       
          INDIANRI     OP     9440     230 KV    CB             .000         .000       
          INDIANRI     OP     232      230 KV    CB             .000         .000       
 5680    EDDYSTONE-ISLAND ROAD 230 LINE                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ISLANDRD     L      EDD-ISL  230 KV                   .000         .000      P
          ISLANDRD     LD     7BUS     13 KV                    .000         .000      P
 5690    L138.Siegfried-Jackson.2                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JACK PL      OP     SIEG_2CB 138 KV    CB             .000         .000       
          EFFRTMTN     OP     EMT2     138 KV    DIS            .000         .000       
          JACK PL      OP     SIEGMON2 138 KV    CB             .000         .000       
          EFFRTMTN     CL     EMT1     138 KV    DIS            .000         .000       
          GILBERTT     L      GIL-SIE2 138 KV                   .000         .000       
          MCMICHLS     L      JAC-MCM1 138 KV                   .000         .000       
          SIEGFRIE     OP     JACKSON  138 KV    CB             .000         .000       
          EFFRTMTN     L      EFF-MCM2 138 KV                   .000         .000       
          EFFRTMTN     L      EFF-GIL2 138 KV                   .000         .000       
 5700    Hunterstown-Jackson (1053) 230 kV line            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HUNTERST     OP     B5       230 KV    CB             .000         .000      P
          JACK ME      L      HUN-JAC  230 KV                   .000         .000      P
          JACK ME      OP     B10      230 KV    CB             .000         .000      P
          JACK ME      OP     B11      230 KV    CB             .000         .000      P
          HUNTERST     OP     105392   230 KV    CB             .000         .000      P
 5710    L230.Stanton-Jenkins.1 + 230/69.TR3               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          JENKINS      OP     ST1-ACAH 230 KV    CB             .000         .000      P
          STANTON      OP     TRAN_3   69 KV     CB             .000         .000      P
          STANTON      OP     JENK1    230 KV    CB             .000         .000      P
          JENKINS      OP     STAN1W   230 KV    CB             .000         .000      P
          STANTON      X      3        230 KV                   .000         .000      P
          JENKINS      L      JEN-STA  230 KV                   .000         .000      P
 5720    L230.Susquehanna-Jenkins + 230/69.Jenkins.T2      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          JENKINS      OP     TRAN_2   69 KV     CB             .000         .000       
          JENKINS      OP     TRAN2MOD 230 KV    DIS            .000         .000       
          JENKINS      OP     SUSQWEST 230 KV    CB             .000         .000       
          JENKINS      OP     SUSQEAST 230 KV    CB             .000         .000       
          JENKINS      L      JEN-SUS  230 KV                   .000         .000       
          SUSQUEHA     OP     JENK     230 KV    CB             .000         .000       
          JENKINS      X      2        230 KV                   .000         .000       
          SUSQUEHA     OP     MONTJENK 230 KV    CB             .000         .000       
 5730    L230.HomerCity-Johnstown                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          JOHNSTOW     OP     B17      230 KV    CB             .000         .000       
          HOMERCIT     OP     201      230 KV    CB             .000         .000       
          JOHNSTOW     L      HOM-JOH  230 KV                   .000         .000       
          HOMERCIT     OP     202      230 KV    CB             .000         .000       
 5740    L230.Johnstown-Seward.2018                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          SEWARD       OP     B4       230 KV    CB             .000         .000      P
          JOHNSTOW     L      JOH-SEW  230 KV                   .000         .000      P
          SEWARD       OP     B-5      230 KV    CB             .000         .000      P
          JOHNSTOW     OP     B14      230 KV    CB             .000         .000      P
 5750    230/115.Johnstown.T2                              Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNNYN YNNYNNNNNNNNNNNNNNNNNNNYN
          JOHNSTOW     OP     B17      230 KV    CB             .000         .000      P
          JOHNSTOW     OP     BSSEC230 230 KV    CB             .000         .000      P
          JOHNSTOW     OP     NO2TX115 115 KV    CB             .000         .000      P
          JOHNSTOW     OP     B7       230 KV    CB             .000         .000      P
          JOHNSTOW     L      BEA-JOH  230 KV                   .000         .000      P
          JOHNSTOW     S      NO2REACT 230 KV                   .000         .000      P
          HOMERCIT     L      HOM-JOH  230 KV                   .000         .000      P
          JOHNSTOW     X      NO2 TX   230 KV                   .000         .000      P
 5760    230/115.Johnstown.T2 + Seneca.1.Pump              Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          JOHNSTOW     OP     B17      230 KV    CB             .000         .000      P
          HOMERCIT     L      HOM-JOH  230 KV                   .000         .000      P
          JOHNSTOW     OP     NO2TX115 115 KV    CB             .000         .000      P
          JOHNSTOW     X      NO2 TX   230 KV                   .000         .000      P
          JOHNSTOW     L      JOH-SEW  230 KV                   .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
          JOHNSTOW     S      NO2REACT 230 KV                   .000         .000      P
          JOHNSTOW     OP     B7       230 KV    CB             .000         .000      P
          JOHNSTOW     L      BEA-JOH  230 KV                   .000         .000      P
          JOHNSTOW     OP     BSSEC230 230 KV    CB             .000         .000      P
          SENECA       U      1GEN     13 KV                    .000         .000      P
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
 5770    230/115.Johnstown.T2 + Seneca.2.Pump              Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       U      2GEN     13 KV                    .000         .000      P
          JOHNSTOW     OP     NO2TX115 115 KV    CB             .000         .000      P
          JOHNSTOW     S      NO2REACT 230 KV                   .000         .000      P
          SENECA       X      NO2 230  230 KV                   .000         .000      P
          JOHNSTOW     OP     BSSEC230 230 KV    CB             .000         .000      P
          JOHNSTOW     OP     B7       230 KV    CB             .000         .000      P
          JOHNSTOW     L      JOH-SEW  230 KV                   .000         .000      P
          JOHNSTOW     L      BEA-JOH  230 KV                   .000         .000      P
          HOMERCIT     L      HOM-JOH  230 KV                   .000         .000      P
          JOHNSTOW     OP     B17      230 KV    CB             .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
          JOHNSTOW     X      NO2 TX   230 KV                   .000         .000      P
 5780    230/115.Johnstown.T2 + Seneca.1&2.Pump            Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          JOHNSTOW     L      JOH-SEW  230 KV                   .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
          JOHNSTOW     OP     NO2TX115 115 KV    CB             .000         .000      P
          SENECA       U      1GEN     13 KV                    .000         .000      P
          JOHNSTOW     OP     BSSEC230 230 KV    CB             .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
          JOHNSTOW     X      NO2 TX   230 KV                   .000         .000      P
          SENECA       X      NO2 230  230 KV                   .000         .000      P
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          JOHNSTOW     S      NO2REACT 230 KV                   .000         .000      P
          JOHNSTOW     OP     B7       230 KV    CB             .000         .000      P
          HOMERCIT     L      HOM-JOH  230 KV                   .000         .000      P
          JOHNSTOW     OP     B17      230 KV    CB             .000         .000      P
          JOHNSTOW     L      BEA-JOH  230 KV                   .000         .000      P
 5790    230/115.Seward.9TX+T11                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          SEWARD       OP     B-2      230 KV    CB             .000         .000      P
          SEWARD       OP     B8       115 KV    CB             .000         .000      P
          SEWARD       X      T11      230 KV                   .000         .000      P
          SEWARD       OP     B-1      230 KV    CB             .000         .000      P
          SEWARD       OP     B7       115 KV    CB             .000         .000      P
          SEWARD       X      9 TX     230 KV                   .000         .000      P
 5800    L230.Lewistown-Juniata                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JUNIATA      OP     LEWI     230 KV    CB             .000         .000      P
          LEWISTOW     OP     JUNIATSF 230 KV    CB             .000         .000      P
          LEWISTOW     OP     B64      230 KV    CB             .000         .000      P
          LEWISTOW     OP     B89      230 KV    CB             .000         .000      P
          JUNIATA      L      JUN-LEW  230 KV                   .000         .000      P
 5810    Harmony-Keeney.23013                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KEENEY       OP     235      230 KV    CB             .000         .000       
          KEENEY       L      HAR-KEE3 230 KV                   .000         .000       
          KEENEY       OP     234      230 KV    CB             .000         .000       
          HARMONY      OP     236      230 KV    CB             .000         .000       
          HARMONY      OP     237      230 KV    CB             .000         .000       
 5820    Harmony-Keeney.23010                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KEENEY       OP     241      230 KV    CB             .000         .000       
          KEENEY       OP     240      230 KV    CB             .000         .000       
          HARMONY      OP     234      230 KV    CB             .000         .000       
          KEENEY       L      HAR-KEE0 230 KV                   .000         .000       
          HARMONY      OP     235      230 KV    CB             .000         .000       
 5830    230/138.Keeney.AT20                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KEENEY       X      AT20     230 KV                   .000         .000      P
          KEENEY       OP     231      230 KV    CB             .000         .000      P
          KEENEY       OP     230      230 KV    CB             .000         .000      P
          KEENEY       OP     131      138 KV    CB             .000         .000      P
          KEENEY       OP     132      138 KV    CB             .000         .000      P
 5840    Keeney-RedLion.23011                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          REDLION      OP     243      230 KV    CB             .000         .000       
          KEENEY       OP     232      230 KV    CB             .000         .000       
          KEENEY       OP     231      230 KV    CB             .000         .000       
          KEENEY       L      KEE-RED  230 KV                   .000         .000       
          REDLION      OP     244      230 KV    CB             .000         .000       
 5850    Keeney-Steele.23009                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KEENEY       OP     240      230 KV    CB             .000         .000       
          STEELE       OP     256      230 KV    CB             .000         .000       
          STEELE       OP     9240     230 KV    CB             .000         .000       
          KEENEY       L      KEE-STE9 230 KV                   .000         .000       
          KEENEY       OP     239      230 KV    CB             .000         .000       
 5860    Keeney-Steele.23001                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STEELE       OP     257      230 KV    CB             .000         .000      P
          STEELE       OP     9210     230 KV    CB             .000         .000      P
          KEENEY       L      KEE-STE1 230 KV                   .000         .000      P
          KEENEY       OP     238      230 KV    CB             .000         .000      P
          KEENEY       OP     237      230 KV    CB             .000         .000      P
 5870    500/230.Keystone.T4                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          KEYSTONE     X      4 TX-P   500 KV                   .000         .000       
          KEYSTONE     X      4 TX-S   230 KV                   .000         .000       
          KEYSTONE     CP     CAP1     500 KV                   .000         .000       
          KEYSTONE     OP     B3       500 KV    CB             .000         .000       
          KEYSTONE     OP     B9       500 KV    CB             .000         .000       
          KEYSTONE     OP     B80      230 KV    CB             .000         .000       
          KEYSTONE     X      4 TX-T   20 KV                    .000         .000       
          KEYSTONE     OP     B16      500 KV    CB             .000         .000       
          KEYSTONE     OP     B6       500 KV    CB             .000         .000       
          KEYSTONE     LD     SS #4    20 KV                    .000         .000       
          KEYSTONE     OP     B81      500 KV    CB             .000         .000       
 5880    500/230.Keystone.T3                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          KEYSTONE     U      UNIT 3   20 KV                    .000         .000       
          KEYSTONE     X      3 TX-T   20 KV                    .000         .000       
          KEYSTONE     OP     B4       500 KV    CB             .000         .000       
          KEYSTONE     LD     SS #3    20 KV                    .000         .000       
          KEYSTONE     X      3 TX-P   500 KV                   .000         .000       
          KEYSTONE     OP     B8       500 KV    CB             .000         .000       
          KEYSTONE     OP     B1       500 KV    CB             .000         .000       
          KEYSTONE     OP     B14      500 KV    CB             .000         .000       
          KEYSTONE     OP     B70      230 KV    CB             .000         .000       
          KEYSTONE     X      3 TX-S   230 KV                   .000         .000       
 5890    L230.Portland-Kittatinny.V1010                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          KITTATIN     OP     BK 1LSD  34 KV     DIS            .000         .000      P
          KITTATIN     OP     NO 9 DI  230 KV    DIS            .000         .000      P
          KITTATIN     L      KIT-POR  230 KV                   .000         .000      P
          KITTATIN     X      BK 1TR   230 KV                   .000         .000      P
          PORTLAND     OP     101012   230 KV    CB             .000         .000      P
          KITTATIN     OP     LV AC    230 KV    CB             .000         .000      P
          KITTATIN     OP     A66      230 KV    DIS            .000         .000      P
          KITTATIN     CP     CAP3     230 KV                   .000         .000      P
          KITTATIN     OP     VT AC    230 KV    CB             .000         .000      P
 5900    L230.Athenia-Cook Rd-Kingsland-NJTMeadows.C-2281  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          COOKRD       L      ATH-COO  230 KV                   .000         .000       
          ATHENIA      OP     3-7      230 KV    CB             .000         .000       
          ATHENIA      OP     1-7      230 KV    CB             .000         .000       
          NJTMEADO     OP     SECT 1-2 230 KV    CB             .000         .000       
          COOKRD       L      COO-KIN  230 KV                   .000         .000       
          NJTMEADO     OP     WESTBREA 230 KV    CB             .000         .000       
          KINGSLAN     L      KIN-NJT  230 KV                   .000         .000       
 5920    L230.Smithburg-Larrabee.H2008+500/230.Smithburg.T4Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LARRABEE     OP     B57      230 KV    CB             .000         .000       
          LARRABEE     OP     H2008_DI 230 KV    DIS            .000         .000       
          SMITHBUR     X      BK 4 50  500 KV                   .000         .000       
          SMITHBUR     OP     BK4230DS 230 KV    DIS            .000         .000       
          SMITHBUR     L      DEA-SMI  500 KV                   .000         .000       
          SMITHBUR     OP     1H GC    230 KV    CB             .000         .000       
          LARRABEE     OP     B48      230 KV    CB             .000         .000       
          SMITHBUR     OP     HA GC    230 KV    CB             .000         .000       
          SMITHBUR     OP     B5       500 KV    CB             .000         .000       
          LARRABEE     L      LAR-SMIH 230 KV                   .000         .000       
 5930    L230.Smithburg-Larrabee.D2004                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LARRABEE     OP     B37      230 KV    CB             .000         .000       
          LARRABEE     OP     BK9230CS 230 KV    DIS            .000         .000       
          LARRABEE     OP     B 12     230 KV    CB             .000         .000       
          SMITHBUR     OP     DA GC    230 KV    CB             .000         .000       
          LARRABEE     L      LAR-SMID 230 KV                   .000         .000       
          SMITHBUR     OP     ED GC    230 KV    CB             .000         .000       
          LARRABEE     LD     BK 9     230 KV                   .000         .000       
 5940    L230.Lakewood-Larrabee.Z2026                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LARRABEE     LD     BK 3     230 KV                   .000         .000      P
          LARRABEE     U      HOWELLSP 230 KV                   .000         .000      P
          LAKEWOOD     OP     ZA GC    230 KV    CB             .000         .000      P
          LARRABEE     OP     B 12     230 KV    CB             .000         .000      P
          LARRABEE     OP     D65      230 KV    DIS            .000         .000      P
          LARRABEE     L      LAK-LAR  230 KV                   .000         .000      P
          LARRABEE     OP     B9       230 KV    CB             .000         .000      P
          LAKEWOOD     OP     ZG GC    230 KV    CB             .000         .000      P
 5950    L230.Atlantic-Larrabee.R1032                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LARRABEE     OP     A36      230 KV    DIS            .000         .000      P
          LARRABEE     L      ATL-LAR  230 KV                   .000         .000      P
          LARRABEE     OP     B63      230 KV    CB             .000         .000      P
          ATLANTIC     OP     B34      230 KV    CB             .000         .000      P
          ATLANTIC     OP     B27      230 KV    CB             .000         .000      P
          LARRABEE     OP     B60      230 KV    CB             .000         .000      P
 5960    L230.Clarksville-Lawrence.D-1018                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CLARKSVI     OP     TRANT-1  230 KV    DIS            .000         .000       
          CLARKSVI     U      CLARKSP  230 KV                   .000         .000       
          LAWRENCE     OP     5-6 CB   230 KV    CB             .000         .000       
          LAWRENCE     L      CLA-LAW  230 KV                   .000         .000       
          CLARKSVI     CL     LOADTRAN 230 KV    DIS            .000         .000       
          LAWRENCE     OP     2-6 CB   230 KV    CB             .000         .000       
 5970    L230.Pleasant Valley(PS)-Lawrence.F-1020          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PLVY PS      OP     SECT2-3  230 KV    CB             .000         .000       
          LAWRENCE     OP     1-3 CB   230 KV    CB             .000         .000       
          LAWRENCE     OP     3-4 CB   230 KV    CB             .000         .000       
          LAWRENCE     OP     F-1020   230 KV    DIS            .000         .000       
          LAWRENCE     L      LAW-PLV  230 KV                   .000         .000       
 5980    BRADFORD-LENAPE 230 LINE                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          LENAPE       OP     785 CB   230 KV    CB             .000         .000      P
          BRADFORD     OP     240 CB   230 KV    CB             .000         .000      P
          LENAPE       L      BRA-LEN  230 KV                   .000         .000      P
          LENAPE       X      LEN1TR   230 KV                   .000         .000      P
          LENAPE       OP     115 CB   35 KV     CB             .000         .000      P
 6000    L230.Aldene-SpringfieldRoad.G-2285                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ALDENE       OP     4-6      230 KV    CB             .000         .000       
          ALDENE       L      ALD-SPRG 230 KV                   .000         .000       
          ALDENE       OP     SECT 2-6 230 KV    CB             .000         .000       
          SPRINGRD     OP     1-2CB    230 KV    CB             .000         .000       
          SPRINGRD     CL     LOADTRAN 230 KV    DIS            .000         .000       
 6010    L230.Aldene-Warinanco.N-2240                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ALDENE       LD     T220-1   230 KV                   .000         .000      P
          ALDENE       OP     4-6      230 KV    CB             .000         .000      P
          ALDENE       OP     DUM14169 230 KV    DIS            .000         .000      P
          ALDENE       OP     1-4      230 KV    CB             .000         .000      P
          WARINANC     OP     SECT1-2  230 KV    CB             .000         .000      P
          WARINANC     L      ALD-WAR  230 KV                   .000         .000      P
          WARINANC     CL     LOADTRAN 230 KV    DIS            .000         .000      P
          WARINANC     OP     TRAN T-2 230 KV    DIS            .000         .000      P
 6020    L138.Hogan-JonesCreek-Aladdin-Strawton            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STRAWTON     OP     C        138 KV    CB             .000         .000      P
          JONESCRE     L      ALA-JON  138 KV                   .000         .000      P
          HOGAN        OP     B CB     138 KV    CB             .000         .000      P
          HOGAN        L      HOG-JON  138 KV                   .000         .000      P
          STRAWTON     OP     C2       138 KV    CB             .000         .000      P
          ALADDIN      OP     V        138 KV    DIS            .000         .000      P
          ALADDIN      OP     U        138 KV    DIS            .000         .000      P
          JONESCRE     OP     U        138 KV    DIS            .000         .000      P
          STRAWTON     L      ALA-STR  138 KV                   .000         .000      P
          JONESCRE     OP     W        138 KV    DIS            .000         .000      P
 6030    Bayonne-PVSC (I-1335) 138 kV line                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BAYONNE      OP     132-2    138 KV    DIS            .000         .000      P
          PVSC         OP     I-1335   138 KV    DIS            .000         .000      P
          BAYONNE      X      132-2 TR 138 KV                   .000         .000      P
          BAYONNE      L      BAY-PVS  138 KV                   .000         .000      P
 6040    LINDEN-BAYWAY (X-1324) 138 LINE                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LINDEN       L      BAY-LINX 138 KV                   .000         .000      P
          BAYWAY       OP     SECT 3-4 138 KV    CB             .000         .000      P
          LINDEN       OP     XTRNSFBU 138 KV    DIS            .000         .000      P
          LINDEN       OP     X-1324   138 KV    CB             .000         .000      P
 6050    BUCKINGHAM-LINTON 230 LINE                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LINTON       L      BUC-LIN  230 KV                   .000         .000      P
          LINTON       X      LIN 2TR  230 KV                   .000         .000      P
 6060    L230.Cookstown-Lumberton.T2246                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LUMBERTO     OP     220-6CB  230 KV    CB             .000         .000      P
          LUMBERTO     OP     2-3      230 KV    CB             .000         .000      P
          LUMBERTO     L      COO-LUM  230 KV                   .000         .000      P
          LUMBERTO     OP     1-3      69 KV     CB             .000         .000      P
          LUMBERTO     OP     3-4      69 KV     CB             .000         .000      P
          COOKSTOW     OP     B37      230 KV    CB             .000         .000      P
          LUMBERTO     X      T-220-6  230 KV                   .000         .000      P
          LUMBERTO     OP     SECT1-2  230 KV    CB             .000         .000      P
          COOKSTOW     OP     B66      230 KV    CB             .000         .000      P
          COOKSTOW     OP     T2246 DI 230 KV    DIS            .000         .000      P
 6070    Alburtis-Lyons (1021) 230 kV line                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LYONS        OP     103172   230 KV    CB             .000         .000      P
          LYONS        OP     B371CB   230 KV    CB             .000         .000      P
          ALBURTME     L      ALB-LYO  230 KV                   .000         .000      P
          ALBURTME     OP     102142   230 KV    CB             .000         .000      P
 6080    L230.NHershey-IronwoodTap-NTemple.1001            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          NHERSHEY     OP     109982   230 KV    CB             .000         .000      P
          IRONWTAP     L      IRO-IRO  230 KV                   .000         .000      P
          NTEMPLE      OP     070112   230 KV    CB             .000         .000      P
          IRONWTAP     L      IRO-NTE  230 KV                   .000         .000      P
          NTEMPLE      OP     100112   230 KV    CB             .000         .000      P
          IRONWTAP     L      IRO-NHE  230 KV                   .000         .000      P
          IRONWOOD     OP     100152   230 KV    CB             .000         .000      P
          IRONWOOD     OP     T-52     230 KV    CB             .000         .000      P
 6090    L230.Lakewood-LeisureVillage.U2021                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LAKEWOOD     OP     UB GC    230 KV    CB             .000         .000       
          LAKEWOOD     LD     TR6      230 KV                   .000         .000       
          LEISUREV     L      LAK-LEI  230 KV                   .000         .000       
          LEISUREV     OP     UC CB    230 KV    CB             .000         .000       
          LAKEWOOD     OP     UA GC    230 KV    CB             .000         .000       
 6100    L230.Lakewood-LeisureVillage.D2030                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LAKEWOOD     OP     DK       230 KV    CB             .000         .000      P
          LEISUREV     LD     BK 4     230 KV                   .000         .000      P
          LAKEWOOD     OP     DB       230 KV    CB             .000         .000      P
          LEISUREV     OP     DA CB    230 KV    CB             .000         .000      P
          LEISUREV     OP     BK2_4L D 230 KV    DIS            .000         .000      P
          LEISUREV     LD     BANK 2   230 KV                   .000         .000      P
          LAKEWOOD     L      LAK-LEI0 230 KV                   .000         .000      P
 6110    L230.Lakewood-Larrabee.K2011                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LARRABEE     OP     B48      230 KV    CB             .000         .000      P
          LARRABEE     L      LAK-LAR1 230 KV                   .000         .000      P
          LAKEWOOD     OP     KG       230 KV    CB             .000         .000      P
          LARRABEE     OP     B51      230 KV    CB             .000         .000      P
          LAKEWOOD     OP     DK       230 KV    CB             .000         .000      P
 6120    L230.Manitou-LeisureVillage.A2027                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MANITOU      OP     BK7LOBKR 35 KV     CB             .000         .000       
          LEISUREV     OP     DA CB    230 KV    CB             .000         .000       
          MANITOU      OP     AO       230 KV    CB             .000         .000       
          MANITOU      OP     AV       230 KV    CB             .000         .000       
          LEISUREV     L      LEI-MANK 230 KV                   .000         .000       
          MANITOU      X      BK 7     230 KV                   .000         .000       
 6130    L230.Manitou-LeisureVillage.C2029                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LEISUREV     OP     UC CB    230 KV    CB             .000         .000      P
          LEISUREV     LD     BK 3     230 KV                   .000         .000      P
          LEISUREV     L      LEI-MANU 230 KV                   .000         .000      P
          LEISUREV     LD     BK 1     230 KV                   .000         .000      P
          MANITOU      OP     NC       230 KV    CB             .000         .000      P
          MANITOU      OP     CF       230 KV    CB             .000         .000      P
          LEISUREV     OP     BK1_3L D 230 KV    DIS            .000         .000      P
 6140    L230.OysterCreek-Manitou.O1029                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          MANITOU      L      MAN-OYSO 230 KV                   .000         .000       
          MANITOU      OP     AO       230 KV    CB             .000         .000       
          OYSTERCR     OP     OD GC    230 KV    CB             .000         .000       
          OYSTERCR     OP     OC GC    230 KV    CB             .000         .000       
          MANITOU      OP     B27      230 KV    CB             .000         .000       
 6150    L230.OysterCreek-Manitou.N1028                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          OYSTERCR     OP     NC GC    230 KV    CB             .000         .000      P
          OYSTERCR     OP     NS GC    230 KV    CB             .000         .000      P
          MANITOU      OP     VN GC    230 KV    CB             .000         .000      P
          MANITOU      OP     NC       230 KV    CB             .000         .000      P
          MANITOU      L      MAN-OYSN 230 KV                   .000         .000      P
 6160    L230.OtterCreek-SafeHarbor-Manor                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          SAFEHARB     OP     TRAN2302 230 KV    CB             .000         .000      P
          OTTCRKPL     OP     YORK     230 KV    CB             .000         .000      P
          SAFEHARB     OP     TR1-NW   13 KV     CB             .000         .000      P
          SAFEHARB     OP     TR1-NE   13 KV     CB             .000         .000      P
          SAFEHARB     OP     TR2-SE   13 KV     CB             .000         .000      P
          SAFEHARB     OP     TR2-SW   13 KV     DIS            .000         .000      P
          MANOR        L      MAN-SAF1 230 KV                   .000         .000      P
          SAFEHARB     X      2301     230 KV                   .000         .000      P
          OTTCRKPL     L      OTT-SAF  230 KV                   .000         .000      P
          SAFEHARB     OP     TR2-NW   13 KV     CB             .000         .000      P
          MANOR        OP     WHEM_2-S 230 KV    CB             .000         .000      P
          SAFEHARB     OP     TRAN2301 230 KV    CB             .000         .000      P
          SAFEHARB     OP     TR2-NE   13 KV     CB             .000         .000      P
          OTTCRKPL     OP     CONA2302 230 KV    CB             .000         .000      P
          SAFEHARB     OP     TR1-SE   13 KV     CB             .000         .000      P
          MANOR        OP     MLWD_S   230 KV    CB             .000         .000      P
          SAFEHARB     OP     TR1-SW   13 KV     DIS            .000         .000      P
          SAFEHARB     X      2302     230 KV                   .000         .000      P
          SAFEHARB     OP     OTT_MOD  230 KV    DIS            .000         .000      P
 6170    L230.Graceton-SafeHarbor-Manor.2303 + SfHrbr.U8-12Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          SAFEHARB     U      UNIT11   13 KV                    .000         .000      P
          SAFEHARB     U      UNIT10   13 KV                    .000         .000      P
          SAFEHARB     U      UNIT12   13 KV                    .000         .000      P
          GRACETON     OP     2303 CB  230 KV    CB             .000         .000      P
          MANOR        OP     MLWD_N   230 KV    CB             .000         .000      P
          SAFEHARB     U      UNIT9    13 KV                    .000         .000      P
          MANOR        OP     WHEM_2-N 230 KV    CB             .000         .000      P
          SAFEHARB     L      GRA-SAF  230 KV                   .000         .000      P
          SAFEHARB     X      2304     230 KV                   .000         .000      P
          GRACETON     OP     2313-03  230 KV    CB             .000         .000      P
          MANOR        L      MAN-SAF2 230 KV                   .000         .000      P
          SAFEHARB     X      2303     230 KV                   .000         .000      P
          SAFEHARB     U      UNIT8    13 KV                    .000         .000      P
 6190    HUDSON 220-2 LINE(HUDSON BUS TIES CLOSED)         Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          HUDSON       OP     3-6      230 KV    CB             .000         .000       
          MARION       OP     220-2    138 KV    CB             .000         .000       
          HUDSON       OP     3-10     230 KV    CB             .000         .000       
          HUDSON       OP     3-8      230 KV    CB             .000         .000       
          HUDSON       L      HUD-MAR2 138 KV                   .000         .000       
          HUDSON       OP     2202 HSD 230 KV    DIS            .000         .000       
          HUDSON       X      HUDSON2  230 KV                   .000         .000       
 6200    L138.Hudson-Marion+230/138.Hudson.T220-2          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HUDSON       OP     3-6      230 KV    CB             .000         .000      P
          HUDSON       L      HUD-MAR2 138 KV                   .000         .000      P
          HUDSON       OP     3-8      230 KV    CB             .000         .000      P
          HUDSON       X      HUDSON2  230 KV                   .000         .000      P
          HUDSON       OP     3-10     230 KV    CB             .000         .000      P
          MARION       OP     220-2    138 KV    CB             .000         .000      P
          HUDSON       OP     2202 HSD 230 KV    DIS            .000         .000      P
          HUDSON       OP     3-4      230 KV    CB             .000         .000      P
 6210    HUDSON 220-1 LINE (HUDSON BUS TIES CLOSED)        Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          HUDSON       OP     1-5      230 KV    CB             .000         .000       
          MARION       OP     220-1    138 KV    CB             .000         .000       
          HUDSON       OP     2201 HSD 230 KV    DIS            .000         .000       
          HUDSON       OP     1-9      230 KV    CB             .000         .000       
          HUDSON       L      HUD-MAR1 138 KV                   .000         .000       
          HUDSON       X      HUDSON1  230 KV                   .000         .000       
          HUDSON       OP     1-7      230 KV    CB             .000         .000       
 6220    L138.Hudson-Marion+230/138.Hudson.T220-1          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HUDSON       OP     2-17     230 KV    CB             .000         .000      P
          HUDSON       OP     2201 HSD 230 KV    DIS            .000         .000      P
          HUDSON       OP     2-13     230 KV    CB             .000         .000      P
          HUDSON       OP     2-15     230 KV    CB             .000         .000      P
          HUDSON       X      HUDSON1  230 KV                   .000         .000      P
          HUDSON       OP     2-11     230 KV    CB             .000         .000      P
          HUDSON       OP     1-2      230 KV    CB             .000         .000      P
          MARION       OP     220-1    138 KV    CB             .000         .000      P
          HUDSON       L      HUD-MAR1 138 KV                   .000         .000      P
 6230    L230.Siegfried-MartinsCreek.2                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          SIEGFRIE     OP     TRAN_2   69 KV     CB             .000         .000      P
          SIEGFRIE     OP     MACR2E   230 KV    CB             .000         .000      P
          MARTINSC     OP     GEN4SIE2 230 KV    CB             .000         .000      P
          MARTINSC     L      MAR-SIE2 230 KV                   .000         .000      P
          SIEGFRIE     X      2        230 KV                   .000         .000      P
          SIEGFRIE     OP     MACR2W   230 KV    CB             .000         .000      P
          MARTINSC     OP     SIEG_2   230 KV    CB             .000         .000      P
          SIEGFRIE     OP     TRAN2MOD 230 KV    DIS            .000         .000      P
 6240    L230.Siegfried-MartinsCreek.1                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          SIEGFRIE     X      1        230 KV                   .000         .000      P
          MARTINSC     L      MAR-SIE1 230 KV                   .000         .000      P
          MARTINSC     OP     2030SIE1 230 KV    CB             .000         .000      P
          SIEGFRIE     OP     MACR_1   230 KV    CB             .000         .000      P
          SIEGFRIE     OP     TRAN_1-E 69 KV     CB             .000         .000      P
          SIEGFRIE     OP     TRAN1MOD 230 KV    DIS            .000         .000      P
          MARTINSC     OP     SIEG_1   230 KV    CB             .000         .000      P
          SIEGFRIE     OP     TRAN_1-W 69 KV     CB             .000         .000      P
 6250    SPS.L765.Marcy-Massena + Massena-Chateuaguay      Y Y Y S Y Y N N     NNNNYNNNNNNNNNNNNNNNNNNNN NNNNYNNNNNNNNNNNNNNNNNNNN
          MARCY        CP     REACT1   765 KV                   .000         .000      P
          MASSENA      OP     7108     765 KV    CB             .000         .000      P
          MARCY        OP     7202     765 KV    CB             .000         .000      P
          MARCY        OP     7214     765 KV    CB             .000         .000      P
          MASSENA      OP     7102     765 KV    CB             .000         .000      P
          MASSENA      OP     7122     765 KV    CB             .000         .000      P
          MASSENA      OP     7208     765 KV    CB             .000         .000      P
          MASSENA      CP     REACT1   765 KV                   .000         .000      P
          CHATEAUG     U      AC-GEN   765 KV                   .000         .000      P
          MASSENA      CP     REACT2   765 KV                   .000         .000      P
          MASSENA      L      CHA-MAS  765 KV                   .000         .000      P
          MASSENA      OP     7222     765 KV    CB             .000         .000      P
          CHATEAUG     U      DC-A     765 KV                   .000         .000      P
          MASSENA      L      MAR-MAS  765 KV                   .000         .000      P
          MASSENA      OP     7214     765 KV    CB             .000         .000      P
          MARCY        OP     7223     765 KV    CB             .000         .000      P
          CHATEAUG     U      DC-B     765 KV                   .000         .000      P
 6260    EDDYSTONE-MASTER 138 LINE                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MASTER       OP     435 CB   138 KV    CB             .000         .000      P
          MASTER       L      EDD-MAS  138 KV                   .000         .000      P
          EDDYSTON     OP     435 CB   138 KV    CB             .000         .000      P
 6270    MASTER MAS 8TR 230-138 TRANSFORMER                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MASTER       OP     85 CB    230 KV    CB             .000         .000      P
          MASTER       OP     825 CB   138 KV    CB             .000         .000      P
          MASTER       X      MAS 8TR  230 KV                   .000         .000      P
 6280    L230.Master-Parrish.220-45                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PARRISH      X      PAR 2TR  230 KV                   .000         .000      P
          PARRISH      OP     2TRLS CB 13 KV     CB             .000         .000      P
          MASTER       OP     455 CB   230 KV    CB             .000         .000      P
          MASTER       L      MAS-PAR  230 KV                   .000         .000      P
          PARRISH      OP     805 CB   230 KV    CB             .000         .000      P
 6290    L230.BrunnerIsland-MiddletownJct                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          BRUNNERI     L      BRU-MID6 230 KV                   .000         .000       
          MIDDLJCT     OP     105682   230 KV    CB             .000         .000       
          BRUNNERI     OP     MIDDLET1 230 KV    CB             .000         .000       
 6300    L230.Brunner Island-Middletown Jct.1005           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          BRUNNERI     L      BRU-MID5 230 KV                   .000         .000       
          BRUNNERI     OP     MIJU2_E  230 KV    CB             .000         .000       
          BRUNNERI     OP     MIJU2_W  230 KV    CB             .000         .000       
          MIDDLJCT     OP     100542   230 KV    CB             .000         .000       
 6310    L230.Hummelst-MiddleJct.1098 + 230/69.Hummelst.T3 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HUMMELST     OP     MIJU_1   230 KV    CB             .000         .000       
          HUMMELST     OP     TRAN_3-E 69 KV     CB             .000         .000       
          MIDDLJCT     OP     109842   230 KV    CB             .000         .000       
          HUMMELST     OP     TRAN_3-W 69 KV     CB             .000         .000       
          HUMMELST     X      3        230 KV                   .000         .000       
          HUMMELST     L      HUM-MID8 230 KV                   .000         .000       
 6320    L230.TMI-MiddletownJunction.1091                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          MIDDLJCT     L      MID-TMI1 230 KV                   .000         .000       
          TMI          OP     109112   230 KV    CB             .000         .000       
          MIDDLJCT     OP     109142   230 KV    CB             .000         .000       
          TMI          OP     109102   230 KV    CB             .000         .000       
 6330    L230.TMI-MiddletownJunction.1092                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MIDDLJCT     L      MID-TMI2 230 KV                   .000         .000       
          TMI          OP     925102   230 KV    CB             .000         .000       
          TMI          OP     109202   230 KV    CB             .000         .000       
          MIDDLJCT     OP     109282   230 KV    CB             .000         .000       
 6340    L230.Mercer-Kuser-LawrenceSub-Lawrence.A-2201     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LAWRENCE     OP     DUM15335 26 KV     DIS            .000         .000       
          LAWRESUB     OP     TRANT-30 230 KV    DIS            .000         .000       
          LAWRENCE     OP     220-1CB  230 KV    CB             .000         .000       
          KUSERRD      OP     TRAN T-2 230 KV    DIS            .000         .000       
          LAWRENCE     L      LAW-LAWA 230 KV                   .000         .000       
          KUSERRD      L      KUS-MERA 230 KV                   .000         .000       
          MERCER       OP     A-2201   230 KV    CB             .000         .000       
          LAWRESUB     CL     T1020TRS 230 KV    DIS            .000         .000       
          KUSERRD      CL     T3-4TRAN 230 KV    DIS            .000         .000       
          LAWRENCE     X      220-1 TR 230 KV                   .000         .000       
          KUSERRD      OP     TRAN T-4 230 KV    DIS            .000         .000       
          LAWRENCE     OP     9-10 CB  230 KV    CB             .000         .000       
          LAWRESUB     CL     T3040TRS 230 KV    DIS            .000         .000       
          LAWRENCE     CL     BUSDUMMY 26 KV     CB             .000         .000       
          KUSERRD      CL     T1-2TRAN 230 KV    DIS            .000         .000       
          KUSERRD      L      KUS-LAW  230 KV                   .000         .000       
          LAWRESUB     OP     TRANT-10 230 KV    DIS            .000         .000       
          LAWRENCE     OP     1-9 CB   230 KV    CB             .000         .000       
 6350    L230.Mercer-Trenton.B2202                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TRENTON      OP     SECT5-6  138 KV    CB             .000         .000       
          TRENTON      L      MER-TRE  230 KV                   .000         .000       
          TRENTON      X      220-2    230 KV                   .000         .000       
          TRENTON      OP     SECT4-5  138 KV    CB             .000         .000       
          MERCER       OP     SECT5-6  230 KV    CB             .000         .000       
          MERCER       OP     SECT1-6  230 KV    CB             .000         .000       
 6360    L69.Lamb-Wenonah-Mantua.0785                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LAMB         L      LAM-WEN  69 KV                    .000         .000       
          WENONAH      LD     LOAD2    69 KV                    .000         .000       
          MANTUA       OP     OCB B    69 KV     CB             .000         .000       
          MANTUA       L      MAN-WEN  69 KV                    .000         .000       
          LAMB         OP     B        69 KV     CB             .000         .000       
          WENONAH      LD     LOAD1    69 KV                    .000         .000       
 6370    L230.Mickleton-Monroe.2304                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MICKLETO     OP     BUSOCBR  230 KV    CB             .000         .000       
          MICKLETO     OP     BUSGCBU  230 KV    CB             .000         .000       
          MICKLETO     L      MIC-MON  230 KV                   .000         .000       
          MONR AE      OP     II       230 KV    CB             .000         .000       
          MONR AE      OP     BUSOCBBB 230 KV    CB             .000         .000       
 6380    230/138.Monroe.T3 (AE)                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MONR AE      OP     JJ       230 KV    CB             .000         .000      P
          MONR AE      X      MON #3   230 KV                   .000         .000      P
          MONR AE      OP     XFMROCBN 138 KV    CB             .000         .000      P
          MONR AE      OP     XFMROCBP 138 KV    CB             .000         .000      P
          MONR AE      OP     II       230 KV    CB             .000         .000      P
 6390    L230.Morton-Middletown.220-66 + 230/34.Middltwn.T4Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MIDD PE      OP     895      230 KV    CB             .000         .000       
          MORTON       OP     565 CB   230 KV    CB             .000         .000       
          MORTON       X      MORTON1  230 KV                   .000         .000       
          MIDD PE      X      4        230 KV                   .000         .000       
          MIDD PE      L      MID-MOR  230 KV                   .000         .000       
          MIDD PE      OP     45       35 KV     CB             .000         .000       
          MORTON       OP     1TRLS CB 13 KV     CB             .000         .000       
          MIDD PE      OP     945      230 KV    CB             .000         .000       
 6400    L230.Milford-Steele.23076                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MILFORD      L      MIL-STE  230 KV                   .000         .000       
          MILFORD      OP     9320     230 KV    CB             .000         .000       
          STEELE       OP     9230     230 KV    CB             .000         .000       
          STEELE       OP     9240     230 KV    CB             .000         .000       
          MILFORD      OP     9310     230 KV    CB             .000         .000       
 6410    WINDYEDGE-HAZEL-ERDMAN-MONUMENT ST 110507         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ERDMAN       OP     507-557  115 KV    CB             .000         .000      P
          ERDMAN       L      ERD-MON7 115 KV                   .000         .000      P
          ERDMAN       L      ERD-WIN1 115 KV                   .000         .000      P
          HAZELWOO     OP     602_604  115 KV    CB             .000         .000      P
          MONUMEST     OP     557_564  115 KV    CB             .000         .000      P
          WINDYEDG     OP     110507   115 KV    CB             .000         .000      P
          HAZELWOO     OP     110604CB 115 KV    CB             .000         .000      P
 6420    L115.GreeneStreet-ConcordStreet.110562            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GREE BC      OP     110-4LS  13 KV     CB             .000         .000      P
          GREE BC      OP     554_562  115 KV    CB             .000         .000      P
          GREE BC      X      110-4    115 KV                   .000         .000      P
          CONC BC      OP     TIE CB   13 KV     CB             .000         .000      P
          CONC BC      OP     110-3HS  115 KV    DIS            .000         .000      P
 6430    L115.WindyEdge-Erdman.110508                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ERDMAN       OP     508_558  115 KV    CB             .000         .000      P
          WINDYEDG     OP     110508   115 KV    CB             .000         .000      P
          ERDMAN       L      ERD-MON8 115 KV                   .000         .000      P
          ERDMAN       L      ERD-WIN2 115 KV                   .000         .000      P
 6440    230/69.Monroe.T5 (AE)                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MONR AE      X      MON #5   230 KV                   .000         .000      P
          MONR AE      OP     XFMROCBS 69 KV     CB             .000         .000      P
          MONR AE      OP     BUSOCBAA 230 KV    CB             .000         .000      P
          MONR AE      OP     LL       230 KV    CB             .000         .000      P
 6450    230/69.Monroe.T6 (AE)                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MONR AE      OP     BUSOCBCC 230 KV    CB             .000         .000      P
          MONR AE      X      MON #6   230 KV                   .000         .000      P
          MONR AE      OP     XFMROCBT 69 KV     CB             .000         .000      P
          MONR AE      OP     BUSOCBBB 230 KV    CB             .000         .000      P
 6460    L230.NewFreedom-Monroe.R-2305                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MONR AE      OP     BUSOCBDD 230 KV    CB             .000         .000      P
          NEWFREED     OP     230 2-4  230 KV    CB             .000         .000      P
          MONR AE      OP     BUSOCBCC 230 KV    CB             .000         .000      P
          NEWFREED     OP     230 3-4  230 KV    CB             .000         .000      P
          MONR AE      L      MON-NEW  230 KV                   .000         .000      P
 6470    L138.JacksonPL-MonroePL.1                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JACK PL      OP     SIEGMONR 138 KV    CB             .000         .000       
          NSTRDSBG     L      BAR-NST  138 KV                   .000         .000       
          TANNERSV     L      BAR-TAN  138 KV                   .000         .000       
          JACK PL      OP     MONR CB  138 KV    CB             .000         .000       
          NSTRDSBG     CP     CAP1     138 KV                   .000         .000       
          JACK PL      L      JAC-TAN  138 KV                   .000         .000       
          MONR PL      OP     JKSN CB  138 KV    CB             .000         .000       
          NSTRDSBG     L      STR-NST  138 KV                   .000         .000       
          MONR PL      L      MON-STR  138 KV                   .000         .000       
 6480    L230.Foxhill-MonroePL                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FOXHILL      OP     B161     230 KV    CB             .000         .000      P
          MONR PL      L      FOX-MON  230 KV                   .000         .000      P
          MONR PL      OP     FOXHILTI 230 KV    CB             .000         .000      P
          FOXHILL      OP     101869 D 230 KV    DIS            .000         .000      P
 6490    L230.MartinsCreek-Monroe + 230/138.Monr.T2        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          MONR PL      X      2 TR     230 KV                   .000         .000      P
          MONR PL      L      MAR-MON  230 KV                   .000         .000      P
          MONR PL      OP     FOXHILTI 230 KV    CB             .000         .000      P
          MONR PL      OP     TRAN2LS  138 KV    CB             .000         .000      P
          MARTINSC     OP     GBRTMONR 230 KV    CB             .000         .000      P
          MARTINSC     OP     MONR     230 KV    CB             .000         .000      P
 6510    L230.Whippany-StonyBrook-Morristown.B1016         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MORRISTO     L      MOR-STO  230 KV                   .000         .000      P
          STON JC      L      STO-WHI  230 KV                   .000         .000      P
          WHIPPANY     OP     B34      230 KV    CB             .000         .000      P
          MORRISTO     OP     B105     230 KV    CB             .000         .000      P
          STON JC      LD     BK 1     230 KV                   .000         .000      P
          WHIPPANY     OP     B2       230 KV    CB             .000         .000      P
 6520    L230.ETowanda-ScotchHollow-Grover-Marshall        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          ETOWANDA     OP     B41      230 KV    CB             .000         .000      P
          GROVER       OP     A4       230 KV    DIS            .000         .000      P
          SCOTCHHO     OP     ETOW     230 KV    DIS            .000         .000      P
          MARSHALL     OP     B1       230 KV    CB             .000         .000      P
          GROVER       X      1TX      230 KV                   .000         .000      P
          MARSHALL     OP     B3       230 KV    CB             .000         .000      P
          GROVER       OP     1TXB     34 KV     CB             .000         .000      P
          ETOWANDA     L      ETO-SCO  230 KV                   .000         .000      P
          ETOWANDA     OP     B31      230 KV    CB             .000         .000      P
          GROVER       L      GRO-MARS 230 KV                   .000         .000      P
          GROVER       OP     A6       230 KV    DIS            .000         .000      P
          GROVER       L      GRO-SCO  230 KV                   .000         .000      P
          SCOTCHHO     OP     GROV     230 KV    DIS            .000         .000      P
          SCOTCHHO     LD     SCOTCH   230 KV                   .000         .000      P
 6530    L230.ETowanda-ScthHollw-Grvr-Marshall+Relay.WarrenY Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          GROVER       OP     A6       230 KV    DIS            .000         .000      P
          GROVER       L      GRO-MARS 230 KV                   .000         .000      P
          MARSHALL     OP     B3       230 KV    CB             .000         .000      P
          WARREN       L      FAL-WAR  115 KV                   .000         .000      P
          GROVER       OP     1TXB     34 KV     CB             .000         .000      P
          GROVER       X      1TX      230 KV                   .000         .000      P
          ETOWANDA     OP     B41      230 KV    CB             .000         .000      P
          GROVER       L      GRO-SCO  230 KV                   .000         .000      P
          MARSHALL     OP     B1       230 KV    CB             .000         .000      P
          WARREN       OP     B32      115 KV    CB             .000         .000      P
          ETOWANDA     OP     B31      230 KV    CB             .000         .000      P
          ETOWANDA     L      ETO-SCO  230 KV                   .000         .000      P
 6540    L230.Moshannon-Shawville.2019                     Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNNYN YNNYNNNNNNNNNNNNNNNNNNNYN
          MOSHANON     OP     B1       230 KV    CB             .000         .000      P
          MOSHANON     OP     B4       230 KV    CB             .000         .000      P
          SHAWVILL     OP     MOSHANSF 230 KV    CB             .000         .000      P
          MOSHANON     L      MOS-SHA  230 KV                   .000         .000      P
 6550    L230.SusquehannaT10-Mountain                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          MOUN UGI     OP     66230    69 KV     CB             .000         .000       
          MOUN UGI     OP     66210    69 KV     CB             .000         .000       
          SUSQT10      OP     MOUNTAIN 230 KV    CB             .000         .000       
          MOUN UGI     OP     23010    230 KV    CB             .000         .000       
          SUSQT10      OP     MOUNT10T 230 KV    CB             .000         .000       
          SUSQT10      OP     MOUNTDIS 230 KV    DIS            .000         .000       
          MOUN UGI     OP     TRAN_1   230 KV    CB             .000         .000       
          MOUN UGI     OP     MONT_MOD 230 KV    DIS            .000         .000       
          MOUN UGI     X      1        230 KV                   .000         .000       
          MOUN UGI     L      MOU-T10  230 KV                   .000         .000       
 6560    L230.Brighton-MtZion-QuinceOrchard.23125/23025    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NORBECK      OP     4TS4B    69 KV     CB             .000         .000       
          NORBECK      OP     4TS1B    69 KV     CB             .000         .000       
          NORBECK      X      158-4T   230 KV                   .000         .000       
          QUINCEOR     OP     23025B   230 KV    CB             .000         .000       
          BRIGHTON     OP     4AB      230 KV    CB             .000         .000       
          MTZION       L      MTZ-NOR9 230 KV                   .000         .000       
          BRIGHTON     L      BRI-MTZ5 230 KV                   .000         .000       
          MTZION       L      MTZ-QUI5 230 KV                   .000         .000       
 6570    L230.QuinceOrchard-BellsMillRoad.23031            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          QUINCEOR     X      118-2T   230 KV                   .000         .000       
          QUINCEOR     OP     69K5B    69 KV     CB             .000         .000       
          BELLSMIL     OP     11TS2B   69 KV     CB             .000         .000       
          QUINCEOR     OP     69K4B    69 KV     CB             .000         .000       
          BELLSMIL     OP     138K9    138 KV    CB             .000         .000       
          BELLSMIL     X      121-11T  230 KV                   .000         .000       
          BELLSMIL     OP     138K8    138 KV    CB             .000         .000       
          BELLSMIL     OP     11TS1B   69 KV     CB             .000         .000       
          QUINCEOR     OP     23022B   230 KV    CB             .000         .000       
          BELLSMIL     CP     4 CAP    230 KV                   .000         .000       
          BELLSMIL     X      121-6T   230 KV                   .000         .000       
          BELLSMIL     L      BEL-QUI1 230 KV                   .000         .000       
          QUINCEOR     OP     23032B   230 KV    CB             .000         .000       
 6580    L230.Brighton-MtZion-QuinceOrchard.23122/23022    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          QUINCEOR     OP     23022B   230 KV    CB             .000         .000       
          BRIGHTON     OP     1AB      230 KV    CB             .000         .000       
          NORBECK      X      158-2T   230 KV                   .000         .000       
          MTZION       L      MTZ-NOR8 230 KV                   .000         .000       
          BRIGHTON     L      BRI-MTZ2 230 KV                   .000         .000       
          NORBECK      OP     2TS3B    69 KV     CB             .000         .000       
          MTZION       L      MTZ-QUI2 230 KV                   .000         .000       
          NORBECK      OP     2TS2B    69 KV     CB             .000         .000       
 6590    L230.Brighton-MtZion-QuinceOrchard.23123/23023    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MTZION       L      MTZ-QUI3 230 KV                   .000         .000      P
          NORBECK      X      158-3T   230 KV                   .000         .000      P
          NORBECK      OP     3TS3B    69 KV     CB             .000         .000      P
          NORBECK      OP     3TS4B    69 KV     CB             .000         .000      P
          MTZION       L      MTZ-NOR1 230 KV                   .000         .000      P
          BRIGHTON     OP     3AB      230 KV    CB             .000         .000      P
          BRIGHTON     L      BRI-MTZ3 230 KV                   .000         .000      P
          QUINCEOR     OP     23023B   230 KV    CB             .000         .000      P
 6600    L230.QuinceOrchard-BellsMillRoad.23028            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BELLSMIL     X      121-14T  230 KV                   .000         .000       
          BELLSMIL     CP     1 CAP    230 KV                   .000         .000       
          QUINCEOR     OP     23028B   230 KV    CB             .000         .000       
          BELLSMIL     X      121-4T   230 KV                   .000         .000       
          BELLSMIL     X      121-2T   230 KV                   .000         .000       
          BELLSMIL     OP     138K4    138 KV    CB             .000         .000       
          BELLSMIL     L      BEL-QUI8 230 KV                   .000         .000       
          BELLSMIL     OP     138K6    138 KV    CB             .000         .000       
          BELLSMIL     OP     2TS1B    34 KV     CB             .000         .000       
          BELLSMIL     OP     2TS4B    34 KV     CB             .000         .000       
          BELLSMIL     OP     14TS4B   69 KV     CB             .000         .000       
          BELLSMIL     OP     14TS1B   69 KV     CB             .000         .000       
 6610    L230.WaughChapel-JerichoPark-Bowie.2340           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WAUGHCHA     OP     2340OCB  230 KV    CB             .000         .000       
          WAUGHCHA     OP     2327_40  230 KV    CB             .000         .000       
          JERICHOP     OP     2340-50  230 KV    CB             .000         .000       
          BOWIE        OP     2340B    230 KV    CB             .000         .000       
          JERICHOP     S      2340SD   230 KV                   .000         .000       
          JERICHOP     L      JER-WAU0 230 KV                   .000         .000       
          JERICHOP     L      BOW-JER0 230 KV                   .000         .000       
 6620    L230.Hummelstown-NHershey + NHersh.T1 + Hummel.T2 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NHERSHEY     L      HUM-NHE  230 KV                   .000         .000       
          HUMMELST     OP     NHER_E   230 KV    CB             .000         .000       
          HUMMELST     OP     NHER_W   230 KV    CB             .000         .000       
          NHERSHEY     OP     109982   230 KV    CB             .000         .000       
          HUMMELST     OP     TRAN_2-W 69 KV     CB             .000         .000       
          HUMMELST     OP     TRAN_2-E 69 KV     CB             .000         .000       
          NHERSHEY     X      1BANK    230 KV                   .000         .000       
          HUMMELST     X      2        230 KV                   .000         .000       
 6630    L230.MiddletownJunction-WillowDrive-Copperstone   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MIDDLJCT     OP     B8       230 KV    CB             .000         .000       
          WILLOWDR     L      MIDJ-WIL 230 KV                   .000         .000       
          COPPERST     OP     MIJU-N   230 KV    CB             .000         .000       
          COPPERST     L      COP-WIL  230 KV                   .000         .000       
          COPPERST     OP     MIJU-S   230 KV    CB             .000         .000       
          WILLOWDR     LD     SUNOCO   230 KV                   .000         .000       
 6640    HILLSDALE-NEW MILFORD 230 LINE                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NEWMILFR     L      HIL-NEW  230 KV                   .000         .000       
          NEWMILFR     OP     SECT 1-5 230 KV    CB             .000         .000       
          HILLSDAL     CL     LOADTR56 230 KV    DIS            .000         .000       
          HILLSDAL     OP     T4 CB    230 KV    CB             .000         .000       
          NEWMILFR     OP     V-2222   230 KV    DIS            .000         .000       
          HILLSDAL     OP     V-2222   230 KV    DIS            .000         .000       
          HILLSDAL     CL     LOADTR34 230 KV    DIS            .000         .000       
          NEWMILFR     OP     SECT 5-6 230 KV    CB             .000         .000       
          HILLSDAL     OP     TRAN T-2 230 KV    DIS            .000         .000       
          HILLSDAL     OP     SECT 1-2 230 KV    CB             .000         .000       
          HILLSDAL     CL     LOADTRAN 230 KV    DIS            .000         .000       
 6650    L230.Maywood-Saddlebrook.G-2259                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MAYWOOD      LD     TR2      13 KV                    .000         .000       
          MAYWOOD      L      MAY-SAD  230 KV                   .000         .000       
          MAYWOOD      LD     TR4      13 KV                    .000         .000       
          MAYWOOD      OP     SECT 1-2 230 KV    CB             .000         .000       
          SADDLEBR     OP     1-6      230 KV    CB             .000         .000       
          SADDLEBR     OP     SECT 1-2 230 KV    CB             .000         .000       
 6660    Master-North Philadelphia (220-44) 230 kV line    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MASTER       L      MAS-NPH  230 KV                   .000         .000       
          NPHILADE     OP     875 CB   230 KV    CB             .000         .000       
          MASTER       OP     445 CB   230 KV    CB             .000         .000       
          NPHILADE     X      NP 8TR   230 KV                   .000         .000       
          NPHILADE     OP     85 CB    69 KV     CB             .000         .000       
 6670    N. Phila-Waneeta (220-49) & N. Phila-Westmoreland Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NPHILADE     L      NPH-WMO  230 KV                   .000         .000       
          NPHILADE     X      NP 7TR   230 KV                   .000         .000       
          WANEETA      OP     495 CB   230 KV    CB             .000         .000       
          NPHILADE     OP     75 CB    69 KV     CB             .000         .000       
          NPHILADE     OP     655 CB   230 KV    CB             .000         .000       
          NPHILADE     OP     875 CB   230 KV    CB             .000         .000       
          NPHILADE     L      NPH-WAN  230 KV                   .000         .000       
 6680    L230.Hosensack-NorthTemple.1003                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NTEMPLE      OP     070312   230 KV    CB             .000         .000       
          NTEMPLE      X      NT4      230 KV                   .000         .000       
          NTEMPLE      OP     100312   230 KV    CB             .000         .000       
          NTEMPLE      OP     4B12     69 KV     CB             .000         .000       
          NTEMPLE      L      HOS-NTE  230 KV                   .000         .000       
          HOSENSME     OP     100342   230 KV    CB             .000         .000       
 6690    L230.NorthTemple-Northkill                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NTEMPLE      L      NKI-NTE  230 KV                   .000         .000       
          NTEMPLE      OP     6B12     69 KV     CB             .000         .000       
          NTEMPLE      X      NT6      230 KV                   .000         .000       
          NTEMPLE      OP     070112   230 KV    CB             .000         .000       
          NRTHKILL     OP     B3       230 KV    CB             .000         .000       
          NTEMPLE      OP     100312   230 KV    CB             .000         .000       
          NRTHKILL     OP     B2       230 KV    CB             .000         .000       
 6700    NORTH WALES-WHITPAIN 220-16                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NWALES       X      NW 1TR   230 KV                   .000         .000       
          WHITPAIN     L      NWA-WHI  230 KV                   .000         .000       
 6710    L138.Byberry-Neshaminy.130-17                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BYBERRY      OP     17TRLSCB 13 KV     CB             .000         .000       
          BYBERRY      OP     20TRLSCB 13 KV     CB             .000         .000       
          BYBERRY      X      BYB17TR  138 KV                   .000         .000       
          NESHAMIN     L      BYB-NES  138 KV                   .000         .000       
          BYBERRY      X      BYB20TR  138 KV                   .000         .000       
          BYBERRY      OP     120 CB   138 KV    CB             .000         .000       
          NESHAMIN     OP     175      138 KV    CB             .000         .000       
 6720    L138.Emilie-Neshaminy.130-25                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NESHAMIN     OP     131 DIS  138 KV    DIS            .000         .000       
          NESHAMIN     L      EMI-NES  138 KV                   .000         .000       
          EMILIE       OP     130 CB   138 KV    CB             .000         .000       
 6730    L230.NewFreedom-Cardiff.2310                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NEWFREED     OP     1-14     230 KV    CB             .000         .000       
          CARDIFF      OP     V CB     230 KV    CB             .000         .000       
          NEWFREED     OP     2-14     230 KV    CB             .000         .000       
          NEWFREED     L      CAR-NEW  230 KV                   .000         .000       
          CARDIFF      OP     W CB     230 KV    CB             .000         .000       
 6740    Doremus Place-Newark (N-1366) 138 kV line         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NEWARK       OP     132-1    138 KV    DIS            .000         .000       
          NEWARK       X      132-1-P  138 KV                   .000         .000       
          NEWARK       X      132-1-S  26 KV                    .000         .000       
          NEWARK       OP     132-1 CB 26 KV     CB             .000         .000       
          NEWARK       OP     SECT 1-4 138 KV    CB             .000         .000       
          NEWARK       L      DOR-NEW  138 KV                   .000         .000       
          NEWARK       OP     132-1 CB 13 KV     CB             .000         .000       
          DOREMUSP     OP     N-1366   138 KV    DIS            .000         .000       
          NEWARK       X      132-1-T  13 KV                    .000         .000       
 6750    L230.Bergen-NorthBergen-49thStreet-Hoboken.R-2270 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BERGEN       L      BER-NBE3 230 KV                   .000         .000       
          NBERGEN      OP     TRAN T-1 230 KV    DIS            .000         .000       
          BERGEN       OP     15-16    230 KV    CB             .000         .000       
          HOBOKEN      OP     2-6      230 KV    CB             .000         .000       
          49STREET     L      49T-HOBR 230 KV                   .000         .000       
          HOBOKEN      OP     5-6      230 KV    CB             .000         .000       
          BERGEN       OP     4-16     230 KV    CB             .000         .000       
          49STREET     L      49T-NBE  230 KV                   .000         .000       
          HOBOKEN      OP     R22702-3 230 KV    DIS            .000         .000       
 6760    L230.Newton-Iliff-Montville.N2214                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NEWTON       OP     B3       230 KV    CB             .000         .000       
          ILIFF        OP     LB2_LBSW 230 KV    DIS            .000         .000       
          NEWTON       L      NEW-LLF  230 KV                   .000         .000       
          ILIFF        LD     230LOAD1 230 KV                   .000         .000       
          NEWTON       OP     N2214DIS 230 KV    DIS            .000         .000       
          MONTVILL     OP     B8       230 KV    CB             .000         .000       
          ILIFF        OP     LB19     230 KV    DIS            .000         .000       
          MONTVILL     OP     B7       230 KV    CB             .000         .000       
          ILIFF        L      MNT-LLF  230 KV                   .000         .000       
 6770    L230.MartinsCreek-Northwood.1011                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          NORTHWOO     OP     101156   230 KV    CB             .000         .000       
          MARTINSC     OP     TR21NTIE 230 KV    CB             .000         .000       
          NORTHWOO     L      MAR-NOR  230 KV                   .000         .000       
          MARTINSC     OP     NORT     230 KV    CB             .000         .000       
          NORTHWOO     OP     101152   230 KV    CB             .000         .000       
          NORTHWOO     OP     B251     230 KV    CB             .000         .000       
 6780    L230.Northwood-Quarry                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NORTHWOO     L      NOR-QUA  230 KV                   .000         .000       
          NORTHWOO     OP     6B52     115 KV    CB             .000         .000       
          NORTHWOO     X      6 BANK   230 KV                   .000         .000       
          QUARRY       OP     NORT_E   230 KV    CB             .000         .000       
          NORTHWOO     LD     3 BANK   230 KV                   .000         .000       
          QUARRY       OP     NORT_W   230 KV    CB             .000         .000       
          NORTHWOO     OP     101152   230 KV    CB             .000         .000       
 6790    L230.Cooper-PeachBottomTap-Nottingham.220-08      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NOTTINGH     OP     085      230 KV    CB             .000         .000       
          COOPERPE     OP     125      230 KV    CB             .000         .000       
          COOPERPE     L      COO-PEA  230 KV                   .000         .000       
          NOTTINGH     L      NOT-PEA  230 KV                   .000         .000       
          PEACHTAP     OP     22008DIS 230 KV    DIS            .000         .000       
          NOTTINGH     OP     087      230 KV    DIS            .000         .000       
          PEACHTAP     OP     NOTT DIS 230 KV    DIS            .000         .000       
          COOPERPE     OP     083      230 KV    DIS            .000         .000       
          PEACHTAP     LD     2SU      13 KV                    .000         .000       
          NOTTINGH     OP     089      230 KV    DIS            .000         .000       
 6800    L115.Northwest-Delight-Gwynbrook-MaysChapel.110578Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DELIGHT      CL     1XF_2XF  115 KV    CB             .000         .000       
          SUDBROOK     OP     24TR_577 115 KV    DIS            .000         .000       
          SUDBROOK     CL     13TR_576 115 KV    DIS            .000         .000       
          SUDBROOK     OP     24TR_576 115 KV    DIS            .000         .000       
          DELIGHT      OP     XF1_578  115 KV    CB             .000         .000       
          NRTHWES2     OP     110578-5 115 KV    CB             .000         .000       
          MAYSCHAP     OP     110578-A 115 KV    CB             .000         .000       
          DOLFIELD     L      DOL-SUD6 115 KV                   .000         .000       
          DELIGHT      L      DEL-GWY8 115 KV                   .000         .000       
          NRTHWES2     OP     110578-4 115 KV    CB             .000         .000       
          DOLFIELD     L      DOL-GWY6 115 KV                   .000         .000       
          DELIGHT      L      DEL-NOR8 115 KV                   .000         .000       
          GWYNNBRO     L      GWY-MAY8 115 KV                   .000         .000       
 6810    110501 WINDY EDGE-CHES-E.POINT-GRAY M-RIVERSIDE   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RIVERSID     OP     1TR_501  115 KV    CB             .000         .000       
          GRAYMANO     L      GRA-RIV1 115 KV                   .000         .000       
          EASTPT       L      EAP-GRA1 115 KV                   .000         .000       
          WINDYEDG     OP     110501   115 KV    CB             .000         .000       
          CHESACO      L      CHE-WIN  115 KV                   .000         .000       
          CHESACO      L      CHE-EAP  115 KV                   .000         .000       
 6820    L115.WindyEdge-Riverside.110502                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WINDYEDG     OP     110502   115 KV    CB             .000         .000       
          CHESACO      L      CHE-MID  115 KV                   .000         .000       
          GRAYMANO     L      GRA-RIV2 115 KV                   .000         .000       
          RIVERSID     OP     2TR_502  115 KV    CB             .000         .000       
          CHESACO      L      CHE-GRA  115 KV                   .000         .000       
          FULLERTO     L      FUL-WIN2 115 KV                   .000         .000       
          CHESACO      L      CHE-FUL  115 KV                   .000         .000       
          RIVERSID     X      110-2    115 KV                   .000         .000       
 6830    L115.WINDYEDGE-FULRTON-GLDRG-E.PT-RIVERSID.110503 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FULLERTO     L      FUL-WIN3 115 KV                   .000         .000      P
          WINDYEDG     OP     110503   115 KV    CB             .000         .000      P
          GOLDENRI     OP     1TR503HS 115 KV    CB             .000         .000      P
          FULLERTO     OP     1TR503HS 115 KV    CB             .000         .000      P
          FULLERTO     L      FUL-GOL  115 KV                   .000         .000      P
          GOLDENRI     CL     BUS TIE  13 KV     CB             .000         .000      P
          EASTPT       L      EAP-GOL3 115 KV                   .000         .000      P
          EASTPT       L      EAP-RIV  115 KV                   .000         .000      P
          EASTPT       OP     1103HSCS 115 KV    DIS            .000         .000      P
 6840    L115.WINDYEDG-GOLDNRG-E.PT-GRAYMNR-RIVERSID.110504Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EASTPT       L      EAP-GOL4 115 KV                   .000         .000      P
          GRAYMANO     L      GRA-RIV4 115 KV                   .000         .000      P
          RIVERSID     OP     110504   115 KV    CB             .000         .000      P
          GRAYMANO     OP     XF2_504  115 KV    CB             .000         .000      P
          EASTPT       L      EAP-GRA4 115 KV                   .000         .000      P
          WINDYEDG     OP     110504   115 KV    CB             .000         .000      P
          GOLDENRI     CL     BUS TIE  13 KV     CB             .000         .000      P
          EASTPT       OP     110-2HS  115 KV    DIS            .000         .000      P
          GOLDENRI     OP     1TR504HS 115 KV    CB             .000         .000      P
          GOLDENRI     OP     2TR504HS 115 KV    DIS            .000         .000      P
          GOLDENRI     L      GOL-WIN  115 KV                   .000         .000      P
 6850    L115.Northwest-Delight-Gwynbrook-MaysChapel.110579Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MAYSCHAP     OP     110579-C 115 KV    CB             .000         .000      P
          DELIGHT      CL     1XF_2XF  115 KV    CB             .000         .000      P
          DOLFIELD     L      DOL-GWY7 115 KV                   .000         .000      P
          DELIGHT      OP     XF2_579  115 KV    CB             .000         .000      P
          SUDBROOK     OP     24TR_577 115 KV    DIS            .000         .000      P
          SUDBROOK     CL     13TR_577 115 KV    DIS            .000         .000      P
          DOLFIELD     L      DOL-SUD7 115 KV                   .000         .000      P
          NRTHWES2     OP     574-560  115 KV    CB             .000         .000      P
          NRTHWES2     OP     110579   115 KV    CB             .000         .000      P
          DELIGHT      L      DEL-NOR9 115 KV                   .000         .000      P
          DELIGHT      L      DEL-GWY9 115 KV                   .000         .000      P
          GWYNNBRO     L      GWY-MAY9 115 KV                   .000         .000      P
          SUDBROOK     OP     13TR_576 115 KV    DIS            .000         .000      P
 6860    L230.Conastone-Northwest.2310                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONASTON     OP     2310CB   230 KV    CB             .000         .000      P
          CONASTON     OP     2310_02  230 KV    CB             .000         .000      P
          NRTHWES2     OP     5TR-10   230 KV    CB             .000         .000      P
          NRTHWES2     OP     2371-10  230 KV    CB             .000         .000      P
          NRTHWES2     L      CNS-NOR1 230 KV                   .000         .000      P
 6870    L230.Conastone-Northwest.2322                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONASTON     L      CNS-NOR2 230 KV                   .000         .000      P
          NRTHWES2     OP     4TR-22   230 KV    CB             .000         .000      P
          CONASTON     OP     2322 GCB 230 KV    CB             .000         .000      P
          CONASTON     OP     1TR_2322 230 KV    CB             .000         .000      P
          NRTHWES2     OP     2370-22  230 KV    CB             .000         .000      P
 6880    230/115.Northwest.230-3                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NORTHWES     L      NOR-NOR3 230 KV                   .000         .000       
          NORTHWES     OP     230-3 HS 230 KV    DIS            .000         .000       
          NORTHWES     OP     2371CB   230 KV    CB             .000         .000       
          NORTHWES     OP     230-3LS  115 KV    CB             .000         .000       
          NORTHWES     CP     CAP3     230 KV                   .000         .000       
          NORTHWES     X      230-3    230 KV                   .000         .000       
 6890    230/115.Northwest.230-2                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NORTHWES     OP     230-2LS  115 KV    CB             .000         .000       
          NORTHWES     CP     CAP2     230 KV                   .000         .000       
          NORTHWES     OP     230-2 HS 230 KV    DIS            .000         .000       
          NORTHWES     L      NOR-NOR1 230 KV                   .000         .000       
          NORTHWES     OP     2370CB   230 KV    CB             .000         .000       
          NORTHWES     X      230-2    230 KV                   .000         .000       
 6900    L115.ESayreville-NWaverly-SOwego-Chemung-Hillside Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SOWEGO       OP     96272    115 KV    CB             .000         .000       
          CHEMUNG      OP     1B-44    115 KV    CB             .000         .000       
          NWAVERLY     L      ESA-NWA  115 KV                   .000         .000       
          NWAVERLY     L      NWAV-SOW 115 KV                   .000         .000       
          CHEMUNG      L      CHE-HIL2 115 KV                   .000         .000       
          NWAVERLY     L      CHE-NWA  115 KV                   .000         .000       
          NWAVERLY     OP     CB 01    115 KV    CB             .000         .000       
          CHEMUNG      LD     TB1      115 KV                   .000         .000       
          HILLSIDE     OP     96212    115 KV    CB             .000         .000       
 6910    L230.Burtonsville-OakGrove.23042                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BURTONSV     OP     23042B   230 KV    CB             .000         .000       
          OAKGROVE     OP     13AB     230 KV    CB             .000         .000       
          OAKGROVE     L      BUR-OAK2 230 KV                   .000         .000       
          OAKGROVE     OP     13BB     230 KV    CB             .000         .000       
 6920    L230.Burtonsville-OakGove.23045                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OAKGROVE     OP     9AB      230 KV    CB             .000         .000       
          OAKGROVE     OP     9BB      230 KV    CB             .000         .000       
          BURTONSV     OP     23045B   230 KV    CB             .000         .000       
          OAKGROVE     L      BUR-OAK5 230 KV                   .000         .000       
 6930    L230.ChalkPoint-Aquasco-OakGrove.23062/23152      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHALKPT      OP     6BB      230 KV    CB             .000         .000       
          OAKGROVE     OP     14BB     230 KV    CB             .000         .000       
          OAKGROVE     OP     14CB     230 KV    CB             .000         .000       
          CHALKPT      OP     6AB      230 KV    CB             .000         .000       
          AQUASCO      L      AQU-OAK  230 KV                   .000         .000       
          AQUASCO      L      AQU-CHA1 230 KV                   .000         .000       
 6940    L230.ChalkPoint-OakGrove.23064                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHALKPT      OP     5AB      230 KV    CB             .000         .000       
          CHALKPT      OP     5BB      230 KV    CB             .000         .000       
          OAKGROVE     OP     13CB     230 KV    CB             .000         .000       
          OAKGROVE     L      CHA-OAK4 230 KV                   .000         .000       
          OAKGROVE     OP     13BB     230 KV    CB             .000         .000       
 6950    L230.Morgantown-Hawkins-OakGrove.23077/87         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MORGANTO     OP     5BB      230 KV    CB             .000         .000       
          OAKGROVE     OP     6CB      230 KV    CB             .000         .000       
          HAWKINS      L      HAW-HAW1 230 KV                   .000         .000       
          MORGANTO     OP     5CB      230 KV    CB             .000         .000       
          HAWKINS      L      HAW-OAK7 230 KV                   .000         .000       
          OAKGROVE     OP     6BB      230 KV    CB             .000         .000       
          HAWKINS      L      HAW-MOR7 230 KV                   .000         .000       
 6960    L230.BurchesHill-PalmersCorner.23091              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PALMERS      OP     2TS2B    69 KV     CB             .000         .000       
          PALMERS      L      BUR-PAL1 230 KV                   .000         .000       
          BURCHESH     OP     2BB      230 KV    CB             .000         .000       
          BURCHESH     OP     2AB      230 KV    CB             .000         .000       
          PALMERS      OP     23106B   230 KV    CB             .000         .000       
          PALMERS      OP     2TS3B    69 KV     CB             .000         .000       
          PALMERS      X      084-2T   230 KV                   .000         .000       
 6970    L230.PalmersCorner-BluePlains-Potomac.23106       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BLUEPLAI     CP     083-6R   230 KV                   .000         .000       
          BLUEPLAI     L      BLU-PAL6 230 KV                   .000         .000       
          POTOMAC      OP     8TSB     69 KV     CB             .000         .000       
          BLUEPLAI     OP     LINK6WB  230 KV    CB             .000         .000       
          BLUEPLAI     OP     LINK6B   230 KV    CB             .000         .000       
          POTOMAC      P      8T-PS    69 KV                    .000         .000       
          BLUEPLAI     L      BLU-POT2 230 KV                   .000         .000       
          POTOMAC      X      STAC-8T  230 KV                   .000         .000       
          PALMERS      OP     23106B   230 KV    CB             .000         .000       
 6980    L230.PalmersCorner-BluePlains-PotomacRi.23108     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BLUEPLAI     L      BLU-PAL8 230 KV                   .000         .000       
          PALMERS      OP     23108B   230 KV    CB             .000         .000       
          PALMERS      CP     1085R    230 KV                   .000         .000       
          POTOMAC      OP     9TSB     69 KV     CB             .000         .000       
          BLUEPLAI     L      BLU-POT1 230 KV                   .000         .000       
          POTOMAC      P      9T-PS    69 KV                    .000         .000       
          BLUEPLAI     OP     LINK6RB  230 KV    CB             .000         .000       
          POTOMAC      X      STAC-9T  230 KV                   .000         .000       
          BLUEPLAI     OP     DUM23108 230 KV    DIS            .000         .000       
 6990    L230.BurchesHill-PalmersCorner.23092              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PALMERS      OP     3TS3B    69 KV     CB             .000         .000       
          BURCHESH     OP     3BB      230 KV    CB             .000         .000       
          PALMERS      L      BUR-PAL2 230 KV                   .000         .000       
          PALMERS      OP     3TS4B    69 KV     CB             .000         .000       
          PALMERS      OP     23107B   230 KV    CB             .000         .000       
          PALMERS      X      084-3T   230 KV                   .000         .000       
          BURCHESH     OP     3AB      230 KV    CB             .000         .000       
 7000    L230.PalmersCorner-BluePlains-PotomacRi.23107     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PALMERS      OP     23107B   230 KV    CB             .000         .000       
          BLUEPLAI     L      BLU-POT3 230 KV                   .000         .000       
          BLUEPLAI     CP     083-7R   230 KV                   .000         .000       
          BLUEPLAI     OP     LINK7B   230 KV    CB             .000         .000       
          POTOMAC      OP     7TSB     69 KV     CB             .000         .000       
          POTOMAC      P      7T-PS    69 KV                    .000         .000       
          POTOMAC      X      STAC-7T  230 KV                   .000         .000       
          BLUEPLAI     L      BLU-PAL7 230 KV                   .000         .000       
          BLUEPLAI     OP     107SRB   230 KV    CB             .000         .000       
          POTOMAC      OP     7TPL     230 KV    CB             .000         .000       
          BLUEPLAI     OP     LINK7RB  230 KV    CB             .000         .000       
 7010    L230.BurchesHill-PalmersCorner.23090              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PALMERS      L      BUR-PAL0 230 KV                   .000         .000      P
          PALMERS      OP     23109B   230 KV    CB             .000         .000      P
          PALMERS      OP     4TS4B    69 KV     CB             .000         .000      P
          PALMERS      X      084-4T   230 KV                   .000         .000      P
          BURCHESH     OP     4AB      230 KV    CB             .000         .000      P
          PALMERS      OP     23088B   230 KV    CB             .000         .000      P
          PALMERS      OP     4TS1B    69 KV     CB             .000         .000      P
          BURCHESH     OP     4BB      230 KV    CB             .000         .000      P
 7020    L230.GraysFerry-Tunnel.220-89 + 230/13.GrysFrry.T1Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TUNNEL       OP     125 CB   230 KV    CB             .000         .000      P
          GRAYSFER     X      1TRAN    230 KV                   .000         .000      P
          GRAYSFER     OP     275 CB   230 KV    CB             .000         .000      P
          TUNNEL       LD     LOAD2    230 KV                   .000         .000      P
          TUNNEL       L      GRA-TUN  230 KV                   .000         .000      P
          TUNNEL       OP     225 CB   230 KV    CB             .000         .000      P
          GRAYSFER     OP     295 CB   230 KV    CB             .000         .000      P
          GRAYSFER     OP     1TRLS    13 KV     CB             .000         .000      P
 7030    L230.GraysFerry-Passyunk.220-11+L69.Pas-SWark.6637Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SWARK        X      SWK56TR  69 KV                    .000         .000       
          PASSYUNK     L      PAS-SWA  69 KV                    .000         .000       
          SWARK        U      UNIT5    13 KV                    .000         .000       
          PASSYUNK     X      PAS 9TR  230 KV                   .000         .000       
          SWARK        U      UNIT6    13 KV                    .000         .000       
          PASSYUNK     L      GRA-PAS  230 KV                   .000         .000       
 7040    L230.Newlinville-Cochranville-PeachBottom.220-34  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          PEACHBOT     LD     343SU    13 KV                    .000         .000      P
          NEWLINVI     X      NEW 3TR  230 KV                   .000         .000      P
          PEACHBOT     L      COC-PEA  230 KV                   .000         .000      P
          PEACHBOT     X      343SU    230 KV                   .000         .000      P
          COCHRNVL     L      COC-NEW  230 KV                   .000         .000      P
          PEACHBOT     OP     345 CB   230 KV    CB             .000         .000      P
          COCHRNVL     LD     1TR      230 KV                   .000         .000      P
          NEWLINVI     OP     270 CB   230 KV    CB             .000         .000      P
          NEWLINVI     OP     260  CB  230 KV    CB             .000         .000      P
 7050    230/69.Copperstone.T1                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          COPPERST     OP     MIJU-N   230 KV    CB             .000         .000       
          COPPERST     X      T1       230 KV                   .000         .000       
          COPPERST     OP     T1 CB    69 KV     CB             .000         .000       
          COPPERST     OP     NLEB-N   230 KV    CB             .000         .000       
 7060    L230.Bridgeport-Pedricktown.2311                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PEDRICKT     OP     BUSGCBA  230 KV    CB             .000         .000      P
          PEDRICKT     OP     BUSGCBC  230 KV    CB             .000         .000      P
          BRIDGEPO     OP     BUSGCBC  230 KV    CB             .000         .000      P
          BRIDGEPO     OP     BUSGCBA  230 KV    CB             .000         .000      P
          PEDRICKT     L      BRI-PED  230 KV                   .000         .000      P
 7070    L115.Portland-PequestRiver.Q927                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PEQUESTR     X      BK 2     115 KV                   .000         .000      P
          PEQUESTR     L      PEQ-POR  115 KV                   .000         .000      P
 7080    L230.RaphaelRoad-OtterPoint-Perryman.2360         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OTTERPT      OP     DUM2360B 230 KV    CB             .000         .000      P
          PERRYMAN     CL     230-1_2  230 KV    DIS            .000         .000      P
          OTTERPT      S      2360SD   230 KV                   .000         .000      P
          OTTERPT      L      OTT-RAP0 230 KV                   .000         .000      P
          OTTERPT      L      OTT-PER0 230 KV                   .000         .000      P
          RAPHAERD     OP     2360_1B  230 KV    CB             .000         .000      P
          OTTERPT      OP     2360 OCB 230 KV    CB             .000         .000      P
          OTTERPT      CL     1_2TIE   230 KV    DIS            .000         .000      P
          PERRYMAN     OP     230-1GCB 230 KV    DIS            .000         .000      P
          RAPHAERD     OP     2360_2B  230 KV    CB             .000         .000      P
 7090    L230.RaphaelRoad-OtterPoint-Perryman.2361         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OTTERPT      L      OTT-RAP1 230 KV                   .000         .000      P
          OTTERPT      OP     2361 OCB 230 KV    CB             .000         .000      P
          OTTERPT      S      2361SD   230 KV                   .000         .000      P
          OTTERPT      L      OTT-PER1 230 KV                   .000         .000      P
          RAPHAERD     OP     2361_1B  230 KV    CB             .000         .000      P
          OTTERPT      CL     1_2TIE   230 KV    DIS            .000         .000      P
          PERRYMAN     OP     230-2GCB 230 KV    DIS            .000         .000      P
          RAPHAERD     OP     2361_2B  230 KV    CB             .000         .000      P
          PERRYMAN     CL     230-1_2  230 KV    DIS            .000         .000      P
 7110    L230.Deans-PiersonAve-Metchuen.S-2219             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DEANS        OP     SECT1-11 230 KV    CB             .000         .000      P
          METUCHEN     OP     5-6      230 KV    CB             .000         .000      P
          METUCHEN     L      MET-PIE  230 KV                   .000         .000      P
          PIERSOAV     CL     LOADTRAN 230 KV    DIS            .000         .000      P
          DEANS        L      DEA-PIES 230 KV                   .000         .000      P
          DEANS        OP     SECT2-11 230 KV    CB             .000         .000      P
          METUCHEN     OP     2-6      230 KV    CB             .000         .000      P
 7120    L69.Monroe-PineHill.0752                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PINEHILL     L      MON-PIN  69 KV                    .000         .000      P
          PINEHILL     OP     OCB C    69 KV     CB             .000         .000      P
          MONR AE      OP     GCB E    69 KV     CB             .000         .000      P
 7140    L69.Monroe-WinslowT-Winslow                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WINSLOW      OP     M        69 KV     DIS            .000         .000      P
          WILLIAMS     OP     A        69 KV     CB             .000         .000      P
          MONR AE      L      MON-WIN  69 KV                    .000         .000      P
          MONR AE      OP     GCB D    69 KV     CB             .000         .000      P
          WINSLOWT     L      WIN-WINT 69 KV                    .000         .000      P
          WILLIAMS     L      WIL-WIN  69 KV                    .000         .000      P
 7150    L69.PineHill-Terrace-Pitman.0756                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TERRACE      LD     BUS3     69 KV                    .000         .000      P
          PINEHILL     L      PIN-TER  69 KV                    .000         .000      P
          PINEHILL     OP     OCB A    69 KV     CB             .000         .000      P
          PITMAN       L      PIT-TER  69 KV                    .000         .000      P
          TERRACE      LD     BUS1     69 KV                    .000         .000      P
          PITMAN       OP     OCB D    69 KV     CB             .000         .000      P
 7160    L69.Lindenwold-SilverLake.0744                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LINDENWO     L      LIN-SIL  69 KV                    .000         .000      P
          SILVERLA     OP     OCB D    69 KV     CB             .000         .000      P
          LINDENWO     OP     OCB B    69 KV     CB             .000         .000      P
 7170    L230.Bradford-Planebrook.220-02                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          PLANEBRO     OP     25CB     230 KV    CB             .000         .000      P
          BRADFORD     OP     220 CB   230 KV    CB             .000         .000      P
          PLANEBRO     L      BRA-PLA2 230 KV                   .000         .000      P
 7180    L230.Nottingham-Daleville-Bradford.220-05         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NOTTINGH     OP     055      230 KV    CB             .000         .000      P
          BRADFORD     OP     250 CB   230 KV    CB             .000         .000      P
          DALESVIL     LD     2TR      230 KV                   .000         .000      P
          DALESVIL     LD     1TR      230 KV                   .000         .000      P
          DALESVIL     U      CHESTER  230 KV                   .000         .000      P
          BRADFORD     L      BRA-DAL  230 KV                   .000         .000      P
          DALESVIL     L      DAL-NOT  230 KV                   .000         .000      P
 7200    L230.Whitpain-PlymouthMeeting.220-13              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WHITPAIN     OP     135 CB   230 KV    CB             .000         .000      P
          PLYMOUTH     L      PLY-WHI3 230 KV                   .000         .000      P
          PLYMOUTH     OP     135 CB   230 KV    CB             .000         .000      P
 7210    L230.Whitpain-PlymouthMeeting.220-15              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PLYMOUTH     L      PLY-WHI5 230 KV                   .000         .000      P
          PLYMOUTH     OP     155 CB   230 KV    CB             .000         .000      P
          WHITPAIN     OP     155 CB   230 KV    CB             .000         .000      P
 7220    L230.Whitpain-PlymouthMeeting.220-14              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WHITPAIN     OP     145 CB   230 KV    CB             .000         .000      P
          PLYMOUTH     OP     145 CB   230 KV    CB             .000         .000      P
          PLYMOUTH     L      PLY-WHI4 230 KV                   .000         .000      P
 7240    L115.Granite-Hollofield-ViaductAve-Pumphrey.110527Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOLLOFIE     OP     110527B1 115 KV    DIS            .000         .000      P
          VIADUCAV     OP     DUMPUM7  115 KV    DIS            .000         .000      P
          HOLLOFIE     CL     1-2BUSCS 115 KV    DIS            .000         .000      P
          VIADUCAV     OP     527_1XF  115 KV    CB             .000         .000      P
          CHESTNUT     OP     110527A  115 KV    DIS            .000         .000      P
          FRED BC      L      FRE-VIA7 115 KV                   .000         .000      P
          GRANITE      OP     110527-B 115 KV    CB             .000         .000      P
          CHESTNUT     OP     DUM527B  115 KV    DIS            .000         .000      P
          VIADUCAV     OP     528_1XF  115 KV    CB             .000         .000      P
          CHESTNUT     L      CHE-FRE7 115 KV                   .000         .000      P
          CHESTNUT     CL     DUM2728T 115 KV    CB             .000         .000      P
          PUMPHREY     OP     110527   115 KV    CB             .000         .000      P
          FRED BC      OP     110527AB 115 KV    DIS            .000         .000      P
          CHESTNUT     L      CHE-HOL7 115 KV                   .000         .000      P
          HOLLOFIE     OP     527_1B   115 KV    CB             .000         .000      P
          HOLLOFIE     OP     1-2 BUS  115 KV    DIS            .000         .000      P
          FRED BC      OP     110527-A 115 KV    DIS            .000         .000      P
          FRED BC      OP     1_4TR27  115 KV    CB             .000         .000      P
          PUMPHREY     L      PUM-VIA7 115 KV                   .000         .000      P
          HOLLOFIE     OP     110-2H_S 115 KV    DIS            .000         .000      P
          PUMPHREY     OP     527_522  115 KV    CB             .000         .000      P
          GRANITE      OP     561A_27B 115 KV    CB             .000         .000      P
          GRANITE      L      GRA-HOL7 115 KV                   .000         .000      P
          HOLLOFIE     OP     110527B2 115 KV    DIS            .000         .000      P
          VIADUCAV     OP     DUMFRE7  115 KV    DIS            .000         .000      P
 7250    L115.Granite-Hollofield-ViaductAve-Pumphrey.110528Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHESTNUT     OP     110528SF 115 KV    DIS            .000         .000      P
          GRANITE      L      GRA-HOL8 115 KV                   .000         .000      P
          GRANITE      OP     528B_60A 115 KV    CB             .000         .000      P
          PUMPHREY     L      PUM-VIA8 115 KV                   .000         .000      P
          VIADUCAV     OP     527_1XF  115 KV    CB             .000         .000      P
          CHESTNUT     CL     DUM2728T 115 KV    CB             .000         .000      P
          CHESTNUT     L      CHE-FRE8 115 KV                   .000         .000      P
          FRED BC      L      FRE-VIA8 115 KV                   .000         .000      P
          GRANITE      OP     110528-B 115 KV    CB             .000         .000      P
          PUMPHREY     OP     110528   115 KV    CB             .000         .000      P
          CHESTNUT     OP     DUM528A  115 KV    DIS            .000         .000      P
          HOLLOFIE     CL     1-2BUSCS 115 KV    DIS            .000         .000      P
          CHESTNUT     L      CHE-HOL8 115 KV                   .000         .000      P
          HOLLOFIE     OP     1-2 BUS  115 KV    DIS            .000         .000      P
          VIADUCAV     CL     528_1XF  115 KV    CB             .000         .000      P
          HOLLOFIE     OP     110-2H_S 115 KV    DIS            .000         .000      P
          PUMPHREY     OP     528_520  115 KV    CB             .000         .000      P
          FRED BC      OP     1_4TR27  115 KV    CB             .000         .000      P
 7260    Croydon.CT11+CT12+CT21+CT22+CT31+CT32+CT41+CT42   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROYDON      U      UNIT21   13 KV                    .000         .000       
          CROYDON      OP     103 DIS  230 KV    DIS            .000         .000       
          CROYDON      U      UNIT11   13 KV                    .000         .000       
          CROYDON      X      CROY 30  230 KV                   .000         .000       
          CROYDON      X      CROY 40  230 KV                   .000         .000       
          CROYDON      U      UNIT41   13 KV                    .000         .000       
          CROYDON      U      UNIT12   13 KV                    .000         .000       
          CROYDON      U      UNIT32   13 KV                    .000         .000       
          CROYDON      X      CROY 20  230 KV                   .000         .000       
          CROYDON      OP     403 DIS  230 KV    DIS            .000         .000       
          CROYDON      OP     CTBUSDIS 230 KV    DIS            .000         .000       
          CROYDON      X      CROY 10  230 KV                   .000         .000       
          CROYDON      OP     203 DIS  230 KV    DIS            .000         .000       
          CROYDON      U      UNIT22   13 KV                    .000         .000       
          CROYDON      U      UNIT31   13 KV                    .000         .000       
          CROYDON      OP     303 DIS  230 KV    DIS            .000         .000       
          CROYDON      OP     135 CB   230 KV    CB             .000         .000       
          CROYDON      OP     235 CB   230 KV    CB             .000         .000       
          CROYDON      U      UNIT42   13 KV                    .000         .000       
 7270    L345.Ladentown-Ramapo                             Y Y Y S Y Y N N     YNNNYNNNNNNNNNNNNNNNNNNYN YNNNYNNNNNNNNNNNNNNNNNNYN
          RAMAPO       L      LAD-RAM  345 KV                   .000         .000      P
 7290    L230.Northeast-RaphaelRoad.2337                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NORTHEAS     OP     2337CB   230 KV    CB             .000         .000      P
          RAPHAERD     L      NOR-RAP7 230 KV                   .000         .000      P
          RAPHAERD     OP     2337     230 KV    CB             .000         .000      P
          RAPHAERD     OP     2313_37  230 KV    CB             .000         .000      P
 7300    L230.Lewistown-Raystown.2027                      Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNNYN YNNYNNNNNNNNNNNNNNNNNNNYN
          RAYSTOWN     X      NO1 TX   230 KV                   .000         .000      P
          RAYSTOWN     L      LEW-RAY  230 KV                   .000         .000      P
          RAYSTOWN     U      RAYS     46 KV                    .000         .000      P
          LEWISTOW     OP     B5       230 KV    CB             .000         .000      P
          RAYSTOWN     OP     B1       230 KV    CB             .000         .000      P
          RAYSTOWN     OP     CAP CB   230 KV    CB             .000         .000      P
          RAYSTOWN     CP     CAP      230 KV                   .000         .000      P
          RAYSTOWN     LD     ONE      46 KV                    .000         .000      P
 7310    L230.Branchburg-Readington.M-2265                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          READINGT     X      BK 1TR   230 KV                   .000         .000      P
          READINGT     OP     MU OC    230 KV    CB             .000         .000      P
          BRANCHBU     OP     11-13    230 KV    CB             .000         .000      P
          READINGT     L      BRA-REA  230 KV                   .000         .000      P
          BRANCHBU     OP     SECT2-11 230 KV    CB             .000         .000      P
          READINGT     OP     BK 1LCB  35 KV     CB             .000         .000      P
 7320    L230.Readington-Roseland.U-2221                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROSELAND     OP     8-15     230 KV    CB             .000         .000      P
          READINGT     OP     MU OC    230 KV    CB             .000         .000      P
          ROSELAND     OP     8-12     230 KV    CB             .000         .000      P
          READINGT     L      REA-ROS  230 KV                   .000         .000      P
          READINGT     OP     BK 2LCB  35 KV     CB             .000         .000      P
          READINGT     X      BK 2TR   230 KV                   .000         .000      P
 7330    L230.CedarCreek-RedLion.23030                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          REDLION      OP     231      230 KV    CB             .000         .000      P
          REDLION      OP     232      230 KV    CB             .000         .000      P
          CEDARCRE     OP     231      230 KV    CB             .000         .000      P
          REDLION      L      CED-RED  230 KV                   .000         .000      P
          CEDARCRE     OP     230      230 KV    CB             .000         .000      P
 7340    230/138.RedLion.AT20                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          REDLION      OP     130      138 KV    CB             .000         .000      P
          REDLION      OP     231      230 KV    CB             .000         .000      P
          REDLION      OP     131      138 KV    CB             .000         .000      P
          REDLION      X      20       230 KV                   .000         .000      P
          REDLION      OP     230      230 KV    CB             .000         .000      P
 7350    L230.Camden-Richmond.C-220-29                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CAMDEN       OP     13-14    230 KV    CB             .000         .000      P
          RICH PE      OP     297 DI   230 KV    DIS            .000         .000      P
          RICH PE      OP     415 CB   230 KV    CB             .000         .000      P
          CAMDEN       OP     2-14     230 KV    CB             .000         .000      P
          CAMDEN       OP     C-220-29 230 KV    DIS            .000         .000      P
          RICH PE      L      CAM-RIC  230 KV                   .000         .000      P
          RICH PE      OP     475 CB   230 KV    CB             .000         .000      P
          RICH PE      LD     4TR      230 KV                   .000         .000      P
 7360    L115.WndyEdg-Fullertn-GldRngs-EPoint-Rvrsid.110503Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FULLERTO     CL     1TR_502  115 KV    CB             .000         .000      P
          RIVERSID     OP     110503   115 KV    CB             .000         .000      P
          EASTPT       OP     1103HSCS 115 KV    DIS            .000         .000      P
          FULLERTO     L      FUL-WIN3 115 KV                   .000         .000      P
          WINDYEDG     OP     110503   115 KV    CB             .000         .000      P
          FULLERTO     OP     1TR503HS 115 KV    CB             .000         .000      P
          FULLERTO     L      FUL-GOL  115 KV                   .000         .000      P
          GOLDENRI     L      EAP-GOL3 115 KV                   .000         .000      P
          GOLDENRI     OP     2TR504HS 115 KV    DIS            .000         .000      P
          FULLERTO     OP     DUMWIN3  115 KV    DIS            .000         .000      P
          EASTPT       L      EAP-RIV  115 KV                   .000         .000      P
          GOLDENRI     CL     2TR503HS 115 KV    DIS            .000         .000      P
 7380    L230.Northeast-Riverside.2317                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NORTHEAS     L      NOR-RIV7 230 KV                   .000         .000      P
          NORTHEAS     OP     2317CB   230 KV    CB             .000         .000      P
          RIVERSID     OP     2317OCB  230 KV    CB             .000         .000      P
 7390    L345.Ramapo-Rock tavern                           Y Y Y S Y Y N N     YNNNYNNNNNNNNNNNNNNNNNNYN YNNNYNNNNNNNNNNNNNNNNNNYN
          ROCKTAVE     OP     377545   345 KV    CB             .000         .000      P
          RAMAPO       OP     T77-94-2 345 KV    CB             .000         .000      P
          RAMAPO       OP     77-2X    345 KV    CB             .000         .000      P
          ROCKTAVE     L      RAM-ROC  345 KV                   .000         .000      P
          ROCKTAVE     OP     377556   345 KV    CB             .000         .000      P
 7400    EMILIE-ROLLING MILL 138 LINE                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROLL PE      OP     120 CB   138 KV    CB             .000         .000      P
          EMILIE       OP     190 CB   138 KV    CB             .000         .000      P
          ROLL PE      L      EMI-ROL  138 KV                   .000         .000      P
 7410    STEEL TAP-ROLLING MILL 138 LINE                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STEELTAP     L      BIL-STE1 138 KV                   .000         .000      P
          ROLL PE      L      ROL-STE  138 KV                   .000         .000      P
          ROLL PE      OP     130 CB   138 KV    CB             .000         .000      P
          STEELTAP     OP     60       138 KV    CB             .000         .000      P
          BILES        OP     10       138 KV    CB             .000         .000      P
 7420    L230.Montville-Roseland.E-2205                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MONTVILL     OP     B10      230 KV    CB             .000         .000      P
          MONTVILL     OP     B33      230 KV    CB             .000         .000      P
          ROSELAND     OP     2-10     230 KV    CB             .000         .000      P
          ROSELAND     L      MNT-ROS  230 KV                   .000         .000      P
          ROSELAND     OP     E-2205   230 KV    DIS            .000         .000      P
          ROSELAND     OP     2-13     230 KV    CB             .000         .000      P
 7450    L345.Rock Tavern-Roseton                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROSETON      OP     31152    345 KV    CB             .000         .000      P
          ROCKTAVE     OP     31154    345 KV    CB             .000         .000      P
          ROCKTAVE     OP     31153    345 KV    CB             .000         .000      P
          ROSETON      L      ROC-ROS  345 KV                   .000         .000      P
          ROSETON      OP     31151    345 KV    CB             .000         .000      P
 7460    SHADE GAP-ROXBURY 115 LINE                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROXBURY      OP     KR SHD G 115 KV    CB             .000         .000      P
          ROXBURY      L      ROX-SHA  115 KV                   .000         .000      P
          SHADEGAP     OP     KR RXBRY 115 KV    CB             .000         .000      P
 7470    L230.Millwood-SouthAkron + Millwood.T1 + SAkron.T3Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SAKRON       OP     TRAN_3   69 KV     CB             .000         .000      P
          MILLWDPL     X      T1       230 KV                   .000         .000      P
          SAKRON       OP     MLWD_S   230 KV    CB             .000         .000      P
          SAKRON       OP     MLWD_N   230 KV    CB             .000         .000      P
          MILLWDPL     OP     BUSTIE   230 KV    CB             .000         .000      P
          MILLWDPL     OP     T1 LS CB 69 KV     CB             .000         .000      P
          SAKRON       X      3        230 KV                   .000         .000      P
          MILLWDPL     L      MIL-SAK  230 KV                   .000         .000      P
 7480    L230.SManheim-SAkron + 230/69.SMan.T4&SAkron.T4   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SAKRON       X      4        230 KV                   .000         .000      P
          SMANHEIM     OP     LINE_MOD 230 KV    CB             .000         .000      P
          SAKRON       OP     SMAN_4-N 230 KV    CB             .000         .000      P
          SAKRON       OP     SMAN_4-S 230 KV    CB             .000         .000      P
          SAKRON       OP     TRAN_4   69 KV     CB             .000         .000      P
          SMANHEIM     OP     TRAN_4   69 KV     CB             .000         .000      P
          SMANHEIM     X      4        230 KV                   .000         .000      P
          SMANHEIM     L      SAK-SMA  230 KV                   .000         .000      P
 7490    L230.MiddletownJct-SouthLebanon.1004              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SLEBANON     X      2BANK    230 KV                   .000         .000      P
          MIDDLJCT     OP     100482   230 KV    CB             .000         .000      P
          SLEBANON     OP     100422CB 230 KV    CB             .000         .000      P
          SLEBANON     L      MID-SLE  230 KV                   .000         .000      P
          SLEBANON     OP     B221     230 KV    CB             .000         .000      P
          MIDDLJCT     OP     100442   230 KV    CB             .000         .000      P
 7500    SOUTH LEBANON-BERKS 230 KV LINE                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BERKS        OP     SREASLEB 230 KV    CB             .000         .000      P
          BERKS        L      BER-SLE  230 KV                   .000         .000      P
          SLEBANON     OP     107422CB 230 KV    CB             .000         .000      P
          BERKS        OP     LAUSSLEB 230 KV    CB             .000         .000      P
 7510    L230.Cedar-OysterCreek                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          OYSTERCR     OP     SD OC    230 KV    CB             .000         .000      P
          CEDAR        OP     GCB LL   230 KV    CB             .000         .000      P
          CEDAR        OP     GCB NN   230 KV    CB             .000         .000      P
          OYSTERCR     OP     NS GC    230 KV    CB             .000         .000      P
          OYSTERCR     L      CED-OYS  230 KV                   .000         .000      P
 7520    CHICHESTER-SAVILLE 138 LINE                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SAVILLE      L      CHI-SAV  138 KV                   .000         .000      P
 7530    EDDYSTONE-SAVILLE 138 LINE                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SAVILLE      L      EDD-SAV  138 KV                   .000         .000      P
 7540    L230.Sayreville-RedOakB-Parlin.G1047              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SAYREVIL     OP     B144     230 KV    CB             .000         .000      P
          REDOAKB      OP     G1 GCB   230 KV    CB             .000         .000      P
          REDOAKB      U      ST       18 KV                    .000         .000      P
          REDOAKB      L      PAR-REDB 230 KV                   .000         .000      P
          PARLIN       OP     GB GC    230 KV    CB             .000         .000      P
          REDOAKB      L      REDB-SAY 230 KV                   .000         .000      P
          PARLIN       OP     GA GC    230 KV    CB             .000         .000      P
          REDOAKB      U      CT       18 KV                    .000         .000      P
          SAYREVIL     OP     B143     230 KV    CB             .000         .000      P
 7550    230/138.Sewaren.T220-1                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SEWAREN      X      220-1    230 KV                   .000         .000      P
          SEWAREN      OP     13856    138 KV    CB             .000         .000      P
          SEWAREN      OP     220-1LSD 138 KV    DIS            .000         .000      P
          SEWAREN      OP     3-5      138 KV    CB             .000         .000      P
          SEWAREN      OP     1-7      230 KV    CB             .000         .000      P
          SEWAREN      OP     7-8      230 KV    CB             .000         .000      P
 7560    FOXHILL-SHAWNEE 230 LINE                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHAWNEE      L      FOX-SHA  230 KV                   .000         .000      P
          SHAWNEE      X      1 BANK   230 KV                   .000         .000      P
 7580    L230.Lewistown-Shingletown.2023                   Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNNYN YNNYNNNNNNNNNNNNNNNNNNNYN
          SHINGLET     L      LEW-SHI  230 KV                   .000         .000      P
          SHINGLET     OP     LEWISTOW 230 KV    CB             .000         .000      P
          LEWISTOW     OP     SHNGLTWN 230 KV    CB             .000         .000      P
 7590    L230.Shawville-Shingletown.2022                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHINGLET     OP     SHAWVILL 230 KV    CB             .000         .000      P
          SHINGLET     L      SHA-SHI  230 KV                   .000         .000      P
          SHAWVILL     OP     SHNGLTWN 230 KV    CB             .000         .000      P
 7600    L230.NewFreedom-Sickler.M-2213.or.2308            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SICKLER      X      SICK #2  230 KV                   .000         .000      P
          NEWFREED     OP     230 2-6  230 KV    CB             .000         .000      P
          NEWFREED     OP     230 5-6  230 KV    CB             .000         .000      P
          SICKLER      L      NEW-SIC  230 KV                   .000         .000      P
          SICKLER      OP     XFMROCBD 69 KV     CB             .000         .000      P
          SICKLER      OP     XFMROCBG 69 KV     CB             .000         .000      P
          SICKLER      X      SICK #1  230 KV                   .000         .000      P
 7610    L230.Frackville-Siegfried                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          SIEGFRIE     OP     FRAC_E   230 KV    CB             .000         .000      P
          FRACKVIL     OP     SIEGFRIE 230 KV    CB             .000         .000      P
          SIEGFRIE     L      FRA-SIE  230 KV                   .000         .000      P
          SIEGFRIE     OP     FRAC_W   230 KV    CB             .000         .000      P
 7620    L230.Levittown-MtLaurel-CoxsCorner.E-2231         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          COXSCORN     L      COX-MTLE 230 KV                   .000         .000      P
          COXSCORN     OP     1-7      230 KV    CB             .000         .000      P
          MTLAUREL     OP     TRAN T-2 230 KV    DIS            .000         .000      P
          COXSCORN     OP     7-8      230 KV    CB             .000         .000      P
          MTLAUREL     OP     E-2231   230 KV    DIS            .000         .000      P
          LEVITTOW     OP     1-2CB    230 KV    CB             .000         .000      P
          LEVITTOW     L      LEV-MTLE 230 KV                   .000         .000      P
          MTLAUREL     CL     LOADTRAN 230 KV    DIS            .000         .000      P
 7630    L230.Atlantic-NewProspectRoad-Smithburg           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SMITHBUR     OP     GA GC    230 KV    CB             .000         .000      P
          ATLANTIC     OP     B48      230 KV    CB             .000         .000      P
          SMITHBUR     X      BK 2TR   230 KV                   .000         .000      P
          ATLANTIC     L      ATL-NEW  230 KV                   .000         .000      P
          SMITHBUR     OP     MG GC    230 KV    CB             .000         .000      P
          SMITHBUR     OP     BK2230   230 KV    CB             .000         .000      P
          NEWPROSP     L      NEW-SMI  230 KV                   .000         .000      P
          ATLANTIC     OP     B41      230 KV    CB             .000         .000      P
          ATLANTIC     OP     G1021 DI 230 KV    DIS            .000         .000      P
          NEWPROSP     LD     TR2      230 KV                   .000         .000      P
          NEWPROSP     OP     B4       230 KV    CB             .000         .000      P
          NEWPROSP     LD     BK1      230 KV                   .000         .000      P
 7640    L230.Smithburg-Manalapan-Englishtown.M2039        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ENGLISHT     L      ENG-MAN  230 KV                   .000         .000      P
          MANALAPA     LD     BK1      230 KV                   .000         .000      P
          SMITHBUR     L      MAN-SMI  230 KV                   .000         .000      P
          ENGLISHT     OP     B78      230 KV    CB             .000         .000      P
          MANALAPA     LD     BK2      230 KV                   .000         .000      P
          SMITHBUR     OP     MG GC    230 KV    CB             .000         .000      P
          ENGLISHT     OP     B84      230 KV    CB             .000         .000      P
          SMITHBUR     OP     MB GC    230 KV    CB             .000         .000      P
 7650    L230.Atlantic-SouthRiver.P1030                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SRIVER       L      ATL-SRI  230 KV                   .000         .000      P
          SRIVER       OP     PB GC    230 KV    CB             .000         .000      P
          SRIVER       OP     PA GC    230 KV    CB             .000         .000      P
          ATLANTIC     OP     1TRDUM   34 KV     CB             .000         .000      P
          ATLANTIC     OP     A39      230 KV    DIS            .000         .000      P
          ATLANTIC     X      1TRAN    230 KV                   .000         .000      P
          ATLANTIC     OP     B13      230 KV    CB             .000         .000      P
          ATLANTIC     OP     B16      230 KV    CB             .000         .000      P
 7660    L230.Sayreville-RedOakA-SouthRiver.T-1034         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SRIVER       OP     TA GC    230 KV    CB             .000         .000      P
          REDOAKA      U      CT2      18 KV                    .000         .000      P
          REDOAKA      OP     T2 GCB   230 KV    CB             .000         .000      P
          REDOAKA      L      REDA-SAY 230 KV                   .000         .000      P
          REDOAKA      U      CT3      18 KV                    .000         .000      P
          SAYREVIL     OP     B145     230 KV    CB             .000         .000      P
          SRIVER       OP     BT GC    230 KV    CB             .000         .000      P
          SAYREVIL     OP     B146     230 KV    CB             .000         .000      P
          REDOAKA      L      REDA-SRI 230 KV                   .000         .000      P
 7670    LUMBERTON-TABERNACLE-SOUTH HAMPTON 69 LINE        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SAMPTON      OP     DUMT1    69 KV     DIS            .000         .000      P
          TABERNAC     OP     OCB A    69 KV     CB             .000         .000      P
          LUMBERTO     OP     1-9      69 KV     CB             .000         .000      P
          SAMPTON      L      MED-SAM  69 KV                    .000         .000      P
          LUMBERTO     OP     9-10     69 KV     CB             .000         .000      P
          LUMBERTO     L      LUM-SAM  69 KV                    .000         .000      P
          TABERNAC     L      MED-TAB  69 KV                    .000         .000      P
 7680    L138.BlairsvilleEast-SocialHall + 138/115.BEast.T1Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BLAIRSVE     L      BLA-SOC  138 KV                   .000         .000      P
          SOCIALHA     OP     BLAIRSVI 138 KV    CB             .000         .000      P
          BLAIRSVE     OP     SOCHL115 115 KV    CB             .000         .000      P
          BLAIRSVE     X      NO.1 TX  138 KV                   .000         .000      P
 7690    L230.Branchburg-Somerville.C-2203                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SOMERVIL     OP     SECT1-2  230 KV    CB             .000         .000      P
          SOMERVIL     OP     TRANT-2  230 KV    DIS            .000         .000      P
          BRANCHBU     OP     SECT5-6  230 KV    CB             .000         .000      P
          SOMERVIL     CL     LOADTRAN 230 KV    DIS            .000         .000      P
          BRANCHBU     L      BRA-SOM  230 KV                   .000         .000      P
          BRANCHBU     OP     SECT2-6  230 KV    CB             .000         .000      P
 7700    L230.Jenkins-Mountain                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          MOUN UGI     L      JEN-MOU  230 KV                   .000         .000      P
          MOUN UGI     OP     23050    230 KV    CB             .000         .000      P
          JENKINS      OP     MOUNWEST 230 KV    CB             .000         .000      P
          JENKINS      OP     MOUNEAST 230 KV    CB             .000         .000      P
 7710    L230.Mountain-Susquehanna                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          MOUN UGI     OP     23040    230 KV    CB             .000         .000      P
          SUSQUEHA     L      MOU-SUS  230 KV                   .000         .000      P
          SUSQUEHA     OP     STAN_1   230 KV    CB             .000         .000      P
 7720    230/69.Mountain.T3(UGI)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MOUN UGI     L      JEN-MOU  230 KV                   .000         .000      P
          MOUN UGI     OP     66200    69 KV     CB             .000         .000      P
          MOUN UGI     OP     23050    230 KV    CB             .000         .000      P
          MOUN UGI     OP     23040    230 KV    CB             .000         .000      P
          MOUN UGI     X      3        230 KV                   .000         .000      P
          MOUN UGI     L      MOU-SUS  230 KV                   .000         .000      P
 7730    230/69.Mountain.T3(UGI) w/ 23030 closed           Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          MOUN UGI     OP     23050    230 KV    CB             .000         .000      P
          MOUN UGI     X      3        230 KV                   .000         .000      P
          MOUN UGI     OP     23010    230 KV    CB             .000         .000      P
          MOUN UGI     OP     23020    230 KV    CB             .000         .000      P
          MOUN UGI     OP     23040    230 KV    CB             .000         .000      P
          MOUN UGI     L      MOU-SUS  230 KV                   .000         .000      P
          MOUN UGI     L      JEN-MOU  230 KV                   .000         .000      P
          MOUN UGI     CL     23030TIE 230 KV    CB             .000         .000      P
          MOUN UGI     OP     66200    69 KV     CB             .000         .000      P
 7760    L345.HomerCity-PierceBrook+Seneca.2.Pump          Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       X      NO2 230  230 KV                   .000         .000       
          HOMERCIT     OP     305      345 KV    CB             .000         .000       
          PIERCEBR     OP     B5       345 KV    CB             .000         .000       
          PIERCEBR     OP     B4       345 KV    CB             .000         .000       
          HOMERCIT     L      HOM-PIE  345 KV                   .000         .000       
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000       
          SENECA       U      2GEN     13 KV                    .000         .000       
          HOMERCIT     OP     304      345 KV    CB             .000         .000       
 7770    L345.HomerCity-PierceBrook+Seneca.1&2.Pump        Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          HOMERCIT     OP     305      345 KV    CB             .000         .000      P
          HOMERCIT     L      HOM-PIE  345 KV                   .000         .000      P
          SENECA       X      NO2 230  230 KV                   .000         .000      P
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
          SENECA       U      1GEN     13 KV                    .000         .000      P
          HOMERCIT     OP     304      345 KV    CB             .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
          PIERCEBR     OP     B5       345 KV    CB             .000         .000      P
          PIERCEBR     OP     B4       345 KV    CB             .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
 7780    L345.HomerCity-PierceBrook+Seneca.1.Pump          Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       X      NO1 230  230 KV                   .000         .000       
          HOMERCIT     L      HOM-PIE  345 KV                   .000         .000       
          PIERCEBR     OP     B4       345 KV    CB             .000         .000       
          HOMERCIT     OP     304      345 KV    CB             .000         .000       
          HOMERCIT     OP     305      345 KV    CB             .000         .000       
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000       
          PIERCEBR     OP     B5       345 KV    CB             .000         .000       
          SENECA       U      1GEN     13 KV                    .000         .000       
 7800    L230.Sunbury-Susquehanna                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          SUNBURY      L      SUN-SUS  230 KV                   .000         .000      P
          SUSQUEHA     OP     SUNB_1   230 KV    CB             .000         .000      P
          SUNBURY      OP     TRAN22MO 230 KV    DIS            .000         .000      P
          SUNBURY      OP     SUSQ_1   230 KV    CB             .000         .000      P
          SUNBURY      X      22       230 KV                   .000         .000      P
          SUNBURY      OP     TR_BK_22 69 KV     CB             .000         .000      P
          SUSQUEHA     OP     SUNB1HAR 230 KV    CB             .000         .000      P
 7810    L230.Montour-SusquehannaT10                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          SUSQT10      OP     MONTNBUS 230 KV    CB             .000         .000      P
          MONTOUR      OP     GEN1SUTI 230 KV    CB             .000         .000      P
          SUSQT10      OP     MONTSBUS 230 KV    CB             .000         .000      P
          MONTOUR      OP     SUSQ_10  230 KV    CB             .000         .000      P
          SUSQT10      L      MON-T10  230 KV                   .000         .000      P
 7820    L230.Harwood-Susquehanna.2                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          HARWOOD      L      HAR-SUS2 230 KV                   .000         .000      P
          SUSQUEHA     OP     EPAL_E   230 KV    CB             .000         .000      P
          HARWOOD      OP     SUSQ_2   230 KV    CB             .000         .000      P
          SUSQUEHA     OP     EPAL_W   230 KV    CB             .000         .000      P
 7840    L230.Montour-Susquehanna                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          MONTOUR      OP     SUSQ     230 KV    CB             .000         .000      P
          SUSQUEHA     OP     MONTJENK 230 KV    CB             .000         .000      P
          SUSQUEHA     L      MON-SUS  230 KV                   .000         .000      P
          SUSQUEHA     OP     MONT     230 KV    CB             .000         .000      P
          MONTOUR      OP     GEN2SUSQ 230 KV    CB             .000         .000      P
 7850    HUDSON-SOUTH WATER FRONT 230 LINE                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SWATERFR     L      HUD-SWA  230 KV                   .000         .000      P
          HUDSON       OP     5-6      230 KV    CB             .000         .000      P
          HUDSON       OP     3-6      230 KV    CB             .000         .000      P
          SWATERFR     OP     SECT 1-2 230 KV    CB             .000         .000      P
          SWATERFR     OP     SECT 1-8 230 KV    CB             .000         .000      P
 7860    L230.Newport-Hoboken.Y2225                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOBOKEN      L      HOB-NEWY 230 KV                   .000         .000      P
          NEWP PS      OP     1-3      230 KV    CB             .000         .000      P
          HOBOKEN      OP     7-8      230 KV    CB             .000         .000      P
          NEWP PS      OP     T-2220   230 KV    DIS            .000         .000      P
          NEWP PS      OP     3-4      230 KV    CB             .000         .000      P
          HOBOKEN      OP     2-8      230 KV    CB             .000         .000      P
 7870    L230.Newport-South Waterfront.Q-2269              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NEWP PS      OP     2-4      230 KV    CB             .000         .000      P
          SWATERFR     OP     SECT 7-8 230 KV    CB             .000         .000      P
          NEWP PS      OP     Q-2269   230 KV    DIS            .000         .000      P
          SWATERFR     OP     SECT 6-7 230 KV    CB             .000         .000      P
          SWATERFR     L      NEW-SWAQ 230 KV                   .000         .000      P
          NEWP PS      OP     3-4      230 KV    CB             .000         .000      P
 7880    L230.Jackson-TMI.1051                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TMI          OP     925102   230 KV    CB             .000         .000      P
          TMI          OP     105102   230 KV    CB             .000         .000      P
          TMI          L      JAC-TMI  230 KV                   .000         .000      P
          JACK ME      OP     B8       230 KV    CB             .000         .000      P
          JACK ME      OP     B9       230 KV    CB             .000         .000      P
 7890    Jackson #4 230/115kV Transformer                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JACK ME      OP     B10      230 KV    CB             .000         .000      P
          JACK ME      OP     C442     13 KV     CB             .000         .000      P
          JACK ME      OP     B13      115 KV    CB             .000         .000      P
          JACK ME      CP     C446 C   13 KV                    .000         .000      P
          JACK ME      X      4 BA-S   115 KV                   .000         .000      P
          JACK ME      CP     C445 C   13 KV                    .000         .000      P
          JACK ME      OP     B9       230 KV    CB             .000         .000      P
 7900    JENKINTOWN-TABOR 230 LINE                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TABOR        X      TR 1     230 KV                   .000         .000      P
          TABOR        L      JEN-TAB  230 KV                   .000         .000      P
 7910    WANEETA-WAYNE JUNCTION 42-PULASKI 230 1 LINE      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PULASKI      X      PULS3TR  230 KV                   .000         .000      P
          PULASKI      L      PUL-WAY  230 KV                   .000         .000      P
          PULASKI      OP     785 CB   230 KV    CB             .000         .000      P
          WANEETA      L      WAN-WAY2 230 KV                   .000         .000      P
 7920    L69.Monroe-Tansboro.0754                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TANSBORO     L      MON-TAN  69 KV                    .000         .000      P
          TANSBORO     OP     OCB C    69 KV     CB             .000         .000      P
          MONR AE      OP     GCB C    69 KV     CB             .000         .000      P
 7930    L69.Sickler-Tansboro.0776                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TANSBORO     OP     OCB L    69 KV     CB             .000         .000      P
          SICKLER      OP     OCB B    69 KV     CB             .000         .000      P
          SICKLER      L      SIC-TAN  69 KV                    .000         .000      P
 7940    L230.Chichester-Trainer.220-53                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHICHEST     S      L22053   230 KV                   .000         .000      P
          TRAINER      LD     1BUS     230 KV                   .000         .000      P
          CHICHEST     OP     535  CB  230 KV    CB             .000         .000      P
          TRAINER      OP     785 CB   230 KV    CB             .000         .000      P
          TRAINER      L      CHI-TRA  230 KV                   .000         .000      P
 7950    L230.Gillette-SummitJC-Traynor.U-1035             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TRAYNOR      OP     B1       230 KV    CB             .000         .000      P
          GILLETTE     OP     UI AC    230 KV    CB             .000         .000      P
          SUMM JC      L      SUM-TRAU 230 KV                   .000         .000      P
          SUMM JC      LD     TW TX    230 KV                   .000         .000      P
          SUMM JC      L      GIL-SUMU 230 KV                   .000         .000      P
          GILLETTE     LD     BK 1     230 KV                   .000         .000      P
 7960    L230.Gillette-SummitJC-Traynor.X-1038             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SUMM JC      LD     TE TX    230 KV                   .000         .000      P
          TRAYNOR      LD     BK 11    230 KV                   .000         .000      P
          GILLETTE     OP     WX AC    230 KV    CB             .000         .000      P
          TRAYNOR      OP     XY GC    230 KV    CB             .000         .000      P
          SUMM JC      L      GIL-SUMX 230 KV                   .000         .000      P
          SUMM JC      L      SUM-TRAX 230 KV                   .000         .000      P
 7970    PLANEBROOK-TREDYFFRIN-UPPERMERION-FLINT 220-24    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          UPPERMER     X      UP 2TR   230 KV                   .000         .000      P
          FLINT        L      FLI-UPP  230 KV                   .000         .000      P
          TREDYFFR     X      TRED8TR  230 KV                   .000         .000      P
          UPPERMER     OP     20 CB    35 KV     CB             .000         .000      P
          TREDYFFR     OP     845 CB   230 KV    CB             .000         .000      P
          PLANEBRO     OP     245 CB   230 KV    CB             .000         .000      P
          FLINT        OP     705 CB   230 KV    CB             .000         .000      P
          TREDYFFR     X      TRED2TR  230 KV                   .000         .000      P
          TREDYFFR     OP     245      230 KV    CB             .000         .000      P
          TREDYFFR     L      PLA-TRE4 230 KV                   .000         .000      P
          TREDYFFR     OP     2BUS DIS 13 KV     DIS            .000         .000      P
          FLINT        X      FLNT2TR  230 KV                   .000         .000      P
          TREDYFFR     L      TRE-UPP4 230 KV                   .000         .000      P
          TREDYFFR     LD     2BUS     13 KV                    .000         .000      P
 7980    PLMOUTH MEETING-FLINT 220-47                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FLINT        X      FLNT3TR  230 KV                   .000         .000      P
          FLINT        OP     935 DIS  230 KV    DIS            .000         .000      P
          FLINT        L      FLI-PLY  230 KV                   .000         .000      P
          FLINT        OP     477 DIS  230 KV    DIS            .000         .000      P
          PLYMOUTH     OP     475 CB   230 KV    CB             .000         .000      P
          FLINT        OP     705 CB   230 KV    CB             .000         .000      P
 7990    L230.Planebrook-Tredyfferin-Upper Merion.220-09   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TREDYFFR     X      TRED7TR  230 KV                   .000         .000      P
          TREDYFFR     X      TRED1TR  230 KV                   .000         .000      P
          TREDYFFR     L      PLA-TRE9 230 KV                   .000         .000      P
          UPPERMER     X      UP 11TR  230 KV                   .000         .000      P
          TREDYFFR     L      TRE-UPP9 230 KV                   .000         .000      P
 8000    L230.Plymouth Meeting-Upper Merion.220-69         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          UPPERMER     OP     355 CB   230 KV    CB             .000         .000      P
          UPPERMER     L      PLY-UPP  230 KV                   .000         .000      P
          UPPERMER     X      UP 12TR  230 KV                   .000         .000      P
          PLYMOUTH     OP     695 CB   230 KV    CB             .000         .000      P
          UPPERMER     OP     25 CB    13 KV     CB             .000         .000      P
 8010    L230.BrunnerIsland-WestHempfield+230/69.WH.T1     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRUNNERI     S      WHEMPFLD 230 KV                   .000         .000      P
          WHEMPFIE     OP     BRIS     230 KV    CB             .000         .000      P
          BRUNNERI     OP     WHEM_E   230 KV    CB             .000         .000      P
          WHEMPFIE     L      BRU-WHE  230 KV                   .000         .000      P
          WHEMPFIE     OP     TRAN_1   69 KV     CB             .000         .000      P
          BRUNNERI     OP     WHEM     230 KV    CB             .000         .000      P
          WHEMPFIE     X      1        230 KV                   .000         .000      P
          BRUNNERI     OP     WHEM_W   230 KV    CB             .000         .000      P
 8020    L230.Manor-WestHempfield + Manor.T2 + WHempf.T2&T4Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MANOR        OP     TRAN4-CB 69 KV     CB             .000         .000      P
          MANOR        OP     WHEM_2-N 230 KV    CB             .000         .000      P
          WHEMPFIE     OP     TRAN_4   138 KV    CB             .000         .000      P
          WHEMPFIE     OP     MANO_2   230 KV    CB             .000         .000      P
          WHEMPFIE     X      2        230 KV                   .000         .000      P
          WHEMPFIE     OP     TRAN_2   69 KV     CB             .000         .000      P
          WHEMPFIE     X      4        230 KV                   .000         .000      P
          MANOR        X      4        230 KV                   .000         .000      P
          MANOR        L      MAN-WHE  230 KV                   .000         .000      P
          MANOR        OP     WHEM_2-S 230 KV    CB             .000         .000      P
 8030    L230.Steelton-WestShore + 230/69.WestShore.T1     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WSHORE       X      1        230 KV                   .000         .000      P
          STEELTON     OP     TRAN_3SF 230 KV    CB             .000         .000      P
          WSHORE       OP     STEE     230 KV    CB             .000         .000      P
          STEELTON     OP     WSHO     230 KV    CB             .000         .000      P
          WSHORE       L      STE-WSH  230 KV                   .000         .000      P
          WSHORE       OP     TRAN_1   69 KV     CB             .000         .000      P
 8040    L115.Pumphrey-LipinsCorner-Wagner.110535          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WAGNER       OP     110535   115 KV    DIS            .000         .000      P
          WAGNER       OP     535-2TR  115 KV    CB             .000         .000      P
          LIPINSCO     OP     1-4TR535 115 KV    CB             .000         .000      P
          LIPINSCO     OP     1-4TIE   115 KV    DIS            .000         .000      P
          LIPINSCO     L      LIP-PUM5 115 KV                   .000         .000      P
          LIPINSCO     OP     3-6TR535 115 KV    CB             .000         .000      P
          LIPINSCO     L      LIP-WAG5 115 KV                   .000         .000      P
          WAGNER       OP     35-2_3   115 KV    CB             .000         .000      P
          PUMPHREY     OP     521_535  115 KV    CB             .000         .000      P
          PUMPHREY     OP     110535   115 KV    CB             .000         .000      P
          LIPINSCO     OP     2-5TR535 115 KV    CB             .000         .000      P
          LIPINSCO     CL     1-4TR534 115 KV    CB             .000         .000      P
 8050    L115.Pumphrey-LipinsCorner-Wagner.110534          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PUMPHREY     OP     110534   115 KV    CB             .000         .000      P
          WAGNER       OP     34-1OCB  115 KV    CB             .000         .000      P
          LIPINSCO     L      LIP-PUM4 115 KV                   .000         .000      P
          LIPINSCO     OP     2-5TR534 115 KV    CB             .000         .000      P
          LIPINSCO     CL     3-6TR535 115 KV    CB             .000         .000      P
          WAGNER       OP     34-1_403 115 KV    CB             .000         .000      P
          LIPINSCO     CL     2-5TR535 115 KV    CB             .000         .000      P
          LIPINSCO     OP     3-6TR534 115 KV    CB             .000         .000      P
          LIPINSCO     L      LIP-WAG4 115 KV                   .000         .000      P
          PUMPHREY     OP     526_534  115 KV    CB             .000         .000      P
          WAGNER       X      110-1    115 KV                   .000         .000      P
 8060    L115.Pumphrey-Wagner.110532                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WAGNER       OP     32-3OCB  115 KV    CB             .000         .000      P
          WAGNER       X      110-3    115 KV                   .000         .000      P
          PUMPHREY     OP     524_532  115 KV    CB             .000         .000      P
          WAGNER       OP     32-3_402 115 KV    CB             .000         .000      P
          PUMPHREY     OP     110532   115 KV    CB             .000         .000      P
          WAGNER       L      PUM-WAG2 115 KV                   .000         .000      P
 8070    L115.Pumphrey-Wagner.110533                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WAGNER       OP     533_401  115 KV    CB             .000         .000      P
          PUMPHREY     OP     110533   115 KV    CB             .000         .000      P
          WAGNER       OP     110533CB 115 KV    CB             .000         .000      P
          PUMPHREY     OP     533_1TR  115 KV    CB             .000         .000      P
          WAGNER       L      PUM-WAG3 115 KV                   .000         .000      P
 8080    345/230.Waldwick.345-1                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WALDWICK     X      345-1    345 KV                   .000         .000      P
          WALDWICK     OP     SECT3-4  230 KV    CB             .000         .000      P
          WALDWICK     OP     345SC2-4 345 KV    CB             .000         .000      P
          WALDWICK     OP     345SC1-4 345 KV    CB             .000         .000      P
          WALDWICK     OP     SECT1-3  230 KV    CB             .000         .000      P
 8090    L230.Mercer-KuserRoad-Trenton.H2208               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KUSERRD      OP     TRAN T-3 230 KV    DIS            .000         .000      P
          KUSERRD      CL     T3-4TRAN 230 KV    DIS            .000         .000      P
          TRENTON      X      220-1    230 KV                   .000         .000      P
          MERCER       OP     SECT3-4  230 KV    CB             .000         .000      P
          TRENTON      OP     SECT1-11 138 KV    CB             .000         .000      P
          KUSERRD      OP     TRAN T-1 230 KV    DIS            .000         .000      P
          KUSERRD      CL     T1-2TRAN 230 KV    DIS            .000         .000      P
          KUSERRD      L      KUS-MERH 230 KV                   .000         .000      P
          KUSERRD      L      KUS-TRE  230 KV                   .000         .000      P
          MERCER       OP     SECT4-5  230 KV    CB             .000         .000      P
          TRENTON      OP     SECT1011 138 KV    CB             .000         .000      P
 8100    L230.Hillsdale-Waldwick                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HILLSDAL     OP     T3 CB    230 KV    CB             .000         .000      P
          WALDWICK     P      2258PAR  230 KV                   .000         .000      P
          HILLSDAL     CL     LOADTR56 230 KV    DIS            .000         .000      P
          WALDWICK     OP     SECT2-6  230 KV    CB             .000         .000      P
          WALDWICK     L      HIL-WAL  230 KV                   .000         .000      P
          HILLSDAL     CL     LOADTRAN 230 KV    DIS            .000         .000      P
          HILLSDAL     OP     TRAN T-1 230 KV    DIS            .000         .000      P
          HILLSDAL     OP     SECT 1-2 230 KV    CB             .000         .000      P
          WALDWICK     OP     SECT5-6  230 KV    CB             .000         .000      P
          HILLSDAL     CL     LOADTR34 230 KV    DIS            .000         .000      P
 8110    Richmond-Waneeta (220-35) 230 kV line             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RICH PE      OP     575 CB   230 KV    CB             .000         .000       
          WANEETA      OP     355 CB   230 KV    CB             .000         .000       
          RICH PE      OP     525 CB   230 KV    CB             .000         .000       
          WANEETA      L      RIC-WAN  230 KV                   .000         .000       
 8120    WANEETA WAN 8TR 230-138 TRANSFORMER               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WANEETA      OP     85 CB    230 KV    CB             .000         .000       
          WANEETA      OP     885 CB   138 KV    CB             .000         .000       
          WANEETA      X      WAN 8TR  230 KV                   .000         .000       
 8130    BUCKINGHAM-WARRINGTON 230 LINE                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WARRINGT     L      BUC-WAR  230 KV                   .000         .000       
          WARRINGT     OP     195 CB   230 KV    CB             .000         .000       
          BUCKINGH     OP     195 CB   230 KV    CB             .000         .000       
 8140    BUCKINGHAM-WARRINGTON 230 LINE W/ CB 220 OPEN     Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          BUCKINGH     OP     245      230 KV    CB             .000         .000      P
          BUCKINGH     OP     40 CB    35 KV     CB             .000         .000      P
          BUCKINGH     OP     20       35 KV     CB             .000         .000      P
          WARRINGT     OP     195 CB   230 KV    CB             .000         .000      P
          BUCKINGH     OP     325 CB   35 KV     CB             .000         .000      P
          BUCKINGH     OP     23 DIS   230 KV    DIS            .000         .000      P
          BUCKINGH     OP     195 CB   230 KV    CB             .000         .000      P
          WARRINGT     L      BUC-WAR  230 KV                   .000         .000      P
 8150    HARTMAN-WARRINGTON 230 LINE                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WARRINGT     L      HAR-WAR  230 KV                   .000         .000      P
          HARTMAN      OP     785      230 KV    CB             .000         .000      P
          WARRINGT     OP     585 CB   230 KV    CB             .000         .000      P
 8160    L345.ErieWest-Wayne.3004                          Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNYYN YNNYNNNNNNNNNNNNNNNNNNYYN
          WAYNE        OP     B45      345 KV    CB             .000         .000      P
          ERIEW        OP     B82      345 KV    CB             .000         .000      P
          WAYNE        L      ERI-WAY  345 KV                   .000         .000      P
          WAYNE        OP     B30      345 KV    CB             .000         .000      P
          ERIEW        OP     B79      345 KV    CB             .000         .000      P
 8170    L345.HandsomeLake-Wayne                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          WAYNE        OP     B45      345 KV    CB             .000         .000      P
          HANDSOME     OP     WAYNECB  345 KV    CB             .000         .000      P
          HANDSOME     OP     LNTIECB  345 KV    CB             .000         .000      P
          WAYNE        OP     B10      345 KV    CB             .000         .000      P
          HANDSOME     L      HAN-WAY  345 KV                   .000         .000      P
 8180    L345.HandsomeLake-Armstrong                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          HANDSOME     L      ARM-HAN  345 KV                   .000         .000       
          HANDSOME     OP     LNTIECB  345 KV    CB             .000         .000       
          ARMSTRON     OP     B4       345 KV    CB             .000         .000       
          ARMSTRON     OP     B3       345 KV    CB             .000         .000       
          HANDSOME     OP     HOMERCB  345 KV    CB             .000         .000       
 8200    L345.HandsomLake-HomerCity + SPS.HomerCity.U2     Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          HOMERCIT     U      UNIT 3   24 KV                    .000         .000      P
          HOMERCIT     OP     305      345 KV    CB             .000         .000      P
          HOMERCIT     LD     TWO      20 KV                    .000         .000      P
          HOMERCIT     OP     303      345 KV    CB             .000         .000      P
          HOMERCIT     OP     301      345 KV    CB             .000         .000      P
          HOMERCIT     OP     306      345 KV    CB             .000         .000      P
          HOMERCIT     X      NO.2 34  345 KV                   .000         .000      P
          HOMERCIT     OP     302      345 KV    CB             .000         .000      P
          HANDSOME     OP     HOMERCB  345 KV    CB             .000         .000      P
          HANDSOME     OP     LNTIECB  345 KV    CB             .000         .000      P
          HOMERCIT     X      NO.3 34  345 KV                   .000         .000      P
          HOMERCIT     U      UNIT 2   20 KV                    .000         .000      P
 8210    138/69.Wescosville.T1 (Sctnlz F)                  Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNYYNNN NNNNNNNNNNNNNNNNNNNNYYNNN
          WESCOSVI     OP     BUS_1-2  138 KV    CB             .000         .000      P
          WESCOSVI     OP     SIEG_2   138 KV    CB             .000         .000      P
          WESCOSVI     X      1        138 KV                   .000         .000      P
          WESCOSVI     OP     CEAL_2   138 KV    CB             .000         .000      P
          WESCOSVI     OP     BUSSEC13 138 KV    CB             .000         .000      P
          WESCOSVI     OP     BUSTIE13 138 KV    CB             .000         .000      P
          WESCOSVI     OP     TR1OPERB 138 KV    CB             .000         .000      P
          WESCOSVI     OP     TRAN_1   69 KV     CB             .000         .000      P
 8230    138/69.Wescosville.T4                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WESCOSVI     OP     TRAN_4HI 138 KV    CB             .000         .000      P
          WESCOSVI     OP     TRAN_4LO 69 KV     CB             .000         .000      P
          WESCOSVI     X      4        138 KV                   .000         .000      P
 8240    500/230.WaughChapel.500-1                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WAUGHCHA     OP     23411BUS 230 KV    CB             .000         .000      P
          WAUGHCHA     OP     2327OCB  230 KV    CB             .000         .000      P
          WAUGHCHA     OP     500-31B  230 KV    CB             .000         .000      P
          WAUGHCHA     X      500-1    500 KV                   .000         .000      P
          WAUGHCHA     OP     230-2OCB 230 KV    CB             .000         .000      P
          WAUGHCHA     OP     23041BUS 230 KV    CB             .000         .000      P
          WAUGHCHA     OP     500-1CB  500 KV    CB             .000         .000      P
          WAUGHCHA     OP     230-3OCB 230 KV    CB             .000         .000      P
          WAUGHCHA     OP     1TR_5051 500 KV    CB             .000         .000      P
          WAUGHCHA     OP     230-1OCB 230 KV    CB             .000         .000      P
 8250    L230.Buxmont-Whitpain + 230/69.Buxmont.T1         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BUXMONT      OP     WHITHOS3 230 KV    CB             .000         .000       
          WHITPAIN     L      BUX-WHI  230 KV                   .000         .000       
          BUXMONT      OP     TRAN_1   69 KV     CB             .000         .000       
          WHITPAIN     OP     J105 CB  230 KV    CB             .000         .000       
          BUXMONT      X      1        230 KV                   .000         .000       
 8260    WHITPAIN-WHITMARSH-JENKINTOWN (220-17) 230 KV LINEY Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JENKINTO     X      JENK13T  230 KV                   .000         .000      P
          JENKINTO     L      JEN-WHI  230 KV                   .000         .000      P
          WHITEMAR     L      WHI-WHI  230 KV                   .000         .000      P
          WHITPAIN     OP     175 CB   230 KV    CB             .000         .000      P
          JENKINTO     OP     245 DIS  230 KV    CB             .000         .000      P
          JENKINTO     OP     13TRLSCB 13 KV     CB             .000         .000      P
          JENKINTO     OP     220 CB   230 KV    CB             .000         .000      P
          WHITEMAR     OP     177 DIS  230 KV    DIS            .000         .000      P
 8270    L230.Manitou-Whitings.V2022                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MANITOU      OP     AV       230 KV    CB             .000         .000      P
          WHITINGS     OP     BK 4 C   230 KV    CB             .000         .000      P
          MANITOU      X      BK 1     230 KV                   .000         .000      P
          MANITOU      OP     BK1230CS 230 KV    DIS            .000         .000      P
          MANITOU      LD     BK 6     230 KV                   .000         .000      P
          WHITINGS     X      BANK 4TR 230 KV                   .000         .000      P
          WHITINGS     L      MAN-WHI  230 KV                   .000         .000      P
          WHITINGS     OP     BV GC    230 KV    CB             .000         .000      P
          MANITOU      OP     VN GC    230 KV    CB             .000         .000      P
 8280    L230.Traynor-Whippany.Z1040                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TRAYNOR      LD     BK 13    230 KV                   .000         .000      P
          WHIPPANY     L      TRA-WHIZ 230 KV                   .000         .000      P
          WHIPPANY     OP     ZY GC    230 KV    CB             .000         .000      P
          WHIPPANY     OP     B34      230 KV    CB             .000         .000      P
          TRAYNOR      OP     B2       230 KV    CB             .000         .000      P
 8290    L230.Traynor-Whippany.Y1039                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TRAYNOR      LD     BK 14    230 KV                   .000         .000      P
          WHIPPANY     L      TRA-WHIY 230 KV                   .000         .000      P
          WHIPPANY     OP     ZY GC    230 KV    CB             .000         .000      P
          WHIPPANY     OP     YA GC    230 KV    CB             .000         .000      P
          TRAYNOR      OP     XY GC    230 KV    CB             .000         .000      P
 8300    L230.Roseland-Whippany.A-941                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROSELAND     OP     5-14     230 KV    CB             .000         .000      P
          WHIPPANY     L      ROS-WHI  230 KV                   .000         .000      P
          WHIPPANY     OP     YA GC    230 KV    CB             .000         .000      P
          WHIPPANY     OP     AQ GC    230 KV    CB             .000         .000      P
          ROSELAND     OP     5-11     230 KV    CB             .000         .000      P
 8310    L230.Greystone-Whippany.J1024                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WHIPPANY     OP     B57      230 KV    CB             .000         .000      P
          WHIPPANY     L      GRE-WHIJ 230 KV                   .000         .000      P
          GREYSTON     OP     J1024 GC 230 KV    CB             .000         .000      P
          WHIPPANY     OP     B35      230 KV    CB             .000         .000      P
 8320    L230.Greystone-Whippany.Q1031 + 230/115.Whppny.12 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WHIPPANY     OP     BK 7 230 230 KV    CB             .000         .000      P
          GREYSTON     OP     Q1031 AC 230 KV    CB             .000         .000      P
          WHIPPANY     OP     G943 OC  115 KV    CB             .000         .000      P
          WHIPPANY     X      BK 12    230 KV                   .000         .000      P
          WHIPPANY     LD     BK 7     230 KV                   .000         .000      P
          WHIPPANY     L      GRE-WHIQ 230 KV                   .000         .000      P
          WHIPPANY     OP     B57      230 KV    CB             .000         .000      P
          WHIPPANY     OP     AQ GC    230 KV    CB             .000         .000      P
 8330    Mays Chapel-Texas-Windy Edge (110509) 115 kV line Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TEXAS        L      TEX-WIN9 115 KV                   .000         .000      P
          MAYSCHAP     OP     110509   115 KV    CB             .000         .000      P
          WINDYEDG     OP     110509   115 KV    CB             .000         .000      P
          TEXAS        L      MAY-TEX9 115 KV                   .000         .000      P
          TEXAS        OP     7TR_509  115 KV    CB             .000         .000      P
          TEXAS        OP     110509   115 KV    CB             .000         .000      P
          TEXAS        OP     5-6_509  115 KV    CB             .000         .000      P
          TEXAS        CL     5-6_515A 115 KV    CB             .000         .000      P
 8340    L115.Mays Chapel-Texas-Windy Edge.110515          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WINDYEDG     OP     110515   115 KV    CB             .000         .000      P
          TEXAS        CL     7TR_509  115 KV    CB             .000         .000      P
          MAYSCHAP     L      MAY-TEX5 115 KV                   .000         .000      P
          MAYSCHAP     OP     110515-A 115 KV    CB             .000         .000      P
          TEXAS        OP     110515-A 115 KV    CB             .000         .000      P
          TEXAS        L      TEX-WIN5 115 KV                   .000         .000      P
          TEXAS        OP     7TR_515A 115 KV    CB             .000         .000      P
          TEXAS        OP     5-6_515A 115 KV    CB             .000         .000      P
          TEXAS        CL     110509   115 KV    CB             .000         .000      P
 8350    LINTON-WOODBOURNE 230 LINE & 7 TRANSFORMER        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WOODBOUR     X      WDB 7TR  230 KV                   .000         .000      P
          WOODBOUR     OP     805 CB   230 KV    CB             .000         .000      P
          WOODBOUR     L      LIN-WOO  230 KV                   .000         .000      P
          WOODBOUR     OP     775 CB   35 KV     CB             .000         .000      P
          LINTON       OP     593      230 KV    DIS            .000         .000      P
 8360    L115.Westport-GreeneStreet.110554                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GREE BC      OP     554_562  115 KV    CB             .000         .000      P
          WESTPORT     OP     526-554  115 KV    CB             .000         .000      P
          GREE BC      OP     110-3LS  13 KV     CB             .000         .000      P
          GREE BC      X      110-3    115 KV                   .000         .000      P
          WESTPORT     L      GRE-WES4 115 KV                   .000         .000      P
 8370    L115.Westport-GreeneStreet.110553                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GREE BC      OP     110-1LS  13 KV     CB             .000         .000       
          WESTPORT     L      GRE-WES3 115 KV                   .000         .000       
          WESTPORT     OP     524-553  115 KV    CB             .000         .000       
          GREE BC      X      110-1    115 KV                   .000         .000       
          GREE BC      OP     553_59   115 KV    CB             .000         .000       
 8390    L138.Burlington-Bustleton-Crosswicks-WardAv.Z1326 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROSSWIC     OP     T-2 DIS  138 KV    DIS            .000         .000      P
          BUSTLETO     OP     T-1 DIS  138 KV    DIS            .000         .000      P
          BURLINGT     X      5TR      230 KV                   .000         .000      P
          BUSTLETO     L      BUR-BUSZ 138 KV                   .000         .000      P
          WARDAV       OP     Z-F      138 KV    CB             .000         .000      P
          BUSTLETO     CL     LOADTRAN 138 KV    DIS            .000         .000      P
          CROSSWIC     L      CRO-WARZ 138 KV                   .000         .000      P
          BUSTLETO     L      BUS-CHE  138 KV                   .000         .000      P
          CROSSWIC     CL     LOADTRAN 138 KV    DIS            .000         .000      P
          BURLINGT     OP     2-12     230 KV    CB             .000         .000      P
          BURLINGT     OP     1-12     230 KV    CB             .000         .000      P
          CHESTERF     LD     T1       138 KV                   .000         .000      P
          CHESTERF     L      CHE-CRO  138 KV                   .000         .000      P
 8400    L138.Essex-Newark.H-1308                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ESSEX        OP     SECT5XFB 138 KV    DIS            .000         .000       
          ESSEX        OP     SECT 3-5 138 KV    CB             .000         .000       
          NEWARK       OP     SECT 3-6 138 KV    CB             .000         .000       
          ESSEX        L      ESS-NEW  138 KV                   .000         .000       
          NEWARK       OP     SECT 2-5 138 KV    CB             .000         .000       
          NEWARK       OP     SECT 1-4 138 KV    CB             .000         .000       
 8410    WINDY EDGE-GLENARM-COLON-FIVEFORKS 110511         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GLENARM      L      GLE-WIN1 115 KV                   .000         .000      P
          COLONIAL     L      COL-ROC1 115 KV                   .000         .000      P
          COLONIAL     OP     511ABS   115 KV    CB             .000         .000      P
          FIVEFORK     L      FIV-ROC1 115 KV                   .000         .000      P
          ROCKRIDG     CL     1_3TR512 115 KV    CB             .000         .000      P
          FIVEFORK     OP     110511OC 115 KV    CB             .000         .000      P
          ROCKRIDG     OP     1_3TR511 115 KV    CB             .000         .000      P
          COLONIAL     L      COL-GLE1 115 KV                   .000         .000      P
          WINDYEDG     OP     110511   115 KV    CB             .000         .000      P
          ROCKRIDG     OP     2TR511   115 KV    CB             .000         .000      P
 8420    WINDY EDGE-GLENARM-COLON-FIVEFORKS 110512         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROCKRIDG     OP     1_3TR512 115 KV    CB             .000         .000      P
          COLONIAL     L      COL-GLE2 115 KV                   .000         .000      P
          COLONIAL     L      COL-ROC2 115 KV                   .000         .000      P
          FIVEFORK     OP     110512OC 115 KV    CB             .000         .000      P
          ROCKRIDG     OP     2TR512   115 KV    CB             .000         .000      P
          WINDYEDG     OP     110512   115 KV    CB             .000         .000      P
          FIVEFORK     L      FIV-ROC2 115 KV                   .000         .000      P
          GLENARM      OP     1TR_512  115 KV    CB             .000         .000      P
          GLENARM      CL     1TR_511  115 KV    CB             .000         .000      P
          ROCKRIDG     CL     2TR511   115 KV    CB             .000         .000      P
          GLENARM      L      GLE-WIN2 115 KV                   .000         .000      P
          COLONIAL     OP     512ABS   115 KV    CB             .000         .000      P
 8430    L345.Gilboa-Leeds                                 Y Y Y S Y Y N N     YNNNYNNNNNNNNNNNNNNNNNNYN YNNNYNNNNNNNNNNNNNNNNNNYN
          LEEDS        OP     R3       345 KV    CB             .000         .000      P
          GILBOA       OP     3214     345 KV    CB             .000         .000      P
          LEEDS        OP     R395     345 KV    CB             .000         .000      P
          GILBOA       L      GIL-LEE  345 KV                   .000         .000      P
          GILBOA       OP     3208     345 KV    CB             .000         .000      P
 8440    230/69.Mickleton.T1                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MICKLETO     OP     FF       230 KV    CB             .000         .000      P
          MICKLETO     OP     BB       230 KV    CB             .000         .000      P
          MICKLETO     X      MICK #1  230 KV                   .000         .000      P
          MICKLETO     OP     XFMROCBH 69 KV     CB             .000         .000      P
 8450    L230.Brighton-MtZion-QuinceOrchard.23124/23024    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRIGHTON     OP     2AB      230 KV    CB             .000         .000      P
          NORBECK      OP     1TS1B    69 KV     CB             .000         .000      P
          NORBECK      X      NORBT1   230 KV                   .000         .000      P
          BRIGHTON     L      BRI-MTZ4 230 KV                   .000         .000      P
          NORBECK      OP     1TS2B    69 KV     CB             .000         .000      P
          QUINCEOR     OP     23024    230 KV    CB             .000         .000      P
          MTZION       L      MTZ-QUI4 230 KV                   .000         .000      P
          MTZION       L      MTZ-NOR0 230 KV                   .000         .000      P
 8460    L230.QuinceOrchard-BellsMillRoad.23029            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BELLSMIL     X      121-13T  230 KV                   .000         .000      P
          BELLSMIL     OP     1TS2B    34 KV     CB             .000         .000      P
          BELLSMIL     X      121-5T   230 KV                   .000         .000      P
          BELLSMIL     OP     13TS4B   69 KV     CB             .000         .000      P
          BELLSMIL     OP     13TS3B   69 KV     CB             .000         .000      P
          BELLSMIL     CP     2 CAP    230 KV                   .000         .000      P
          BELLSMIL     X      121-1T   230 KV                   .000         .000      P
          BELLSMIL     L      BEL-QUI9 230 KV                   .000         .000      P
          BELLSMIL     OP     138K7    138 KV    CB             .000         .000      P
          BELLSMIL     OP     1TS3B    34 KV     CB             .000         .000      P
          BELLSMIL     OP     138K5    138 KV    CB             .000         .000      P
          QUINCEOR     OP     23029B   230 KV    CB             .000         .000      P
 8470    L230.BurchesHill-PalmersCorner.23093              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PALMERS      OP     23108B   230 KV    CB             .000         .000      P
          BURCHESH     L      BUR-PAL3 230 KV                   .000         .000      P
          PALMERS      OP     1TS2B    69 KV     CB             .000         .000      P
          BURCHESH     OP     1AB      230 KV    CB             .000         .000      P
          PALMERS      OP     1TS1B    69 KV     CB             .000         .000      P
          BURCHESH     OP     1BB      230 KV    CB             .000         .000      P
          PALMERS      OP     23089B   230 KV    CB             .000         .000      P
          PALMERS      X      084-1T   230 KV                   .000         .000      P
 8480    West Wharton-DOT Whar-Elstimold-Pohatcong 230 lineY Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          POHATCON     OP     AL OC    230 KV    CB             .000         .000      P
          WWHARTON     OP     HA OC    230 KV    CB             .000         .000      P
          DOTWWHAR     L      DOT-ELA  230 KV                   .000         .000      P
          WWHARTON     OP     1A3 GCB  230 KV    CB             .000         .000      P
          ELASTIMO     L      ELA-POH  230 KV                   .000         .000      P
          DOTWWHAR     L      DOT-WWH  230 KV                   .000         .000      P
 8490    Concord Street-Monument Street (110564) 115 kV    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONC BC      OP     110-4HS  115 KV    DIS            .000         .000      P
          CONC BC      OP     567564CB 115 KV    CB             .000         .000      P
          MONUMEST     OP     557_564  115 KV    CB             .000         .000      P
          CONC BC      OP     TIE CB2  13 KV     CB             .000         .000      P
          MONUMEST     L      CON-MON  115 KV                   .000         .000      P
 8500    L230.Branchburg-SunnymeadeRoad-BennettsLane.X-2224Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SUNNYMEA     CL     T34TRANS 230 KV    DIS            .000         .000      P
          SUNNYMEA     CL     T12TRANS 230 KV    DIS            .000         .000      P
          BENNETTS     OP     1-2      230 KV    CB             .000         .000      P
          BRANCHBU     OP     SECT1-7  230 KV    CB             .000         .000      P
          SUNNYMEA     L      BEN-SUN  230 KV                   .000         .000      P
          BRANCHBU     L      BRA-SUN  230 KV                   .000         .000      P
          SUNNYMEA     OP     TRANT3   230 KV    DIS            .000         .000      P
          SUNNYMEA     OP     TRANT1   230 KV    DIS            .000         .000      P
          BENNETTS     OP     T-2 CB   230 KV    CB             .000         .000      P
          BRANCHBU     OP     SECT 7-8 230 KV    CB             .000         .000      P
          BENNETTS     CL     LOADTRAN 230 KV    DIS            .000         .000      P
 8510    L230.Buckingham-Rocktown.220-12                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROCKTOWN     OP     B9       230 KV    CB             .000         .000      P
          ROCKTOWN     OP     B2       230 KV    CB             .000         .000      P
          BUCKINGH     OP     230 CB   230 KV    CB             .000         .000      P
          BUCKINGH     L      BUCK-ROC 230 KV                   .000         .000      P
 8520    L500.Branchburg-Deans.5019                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNYYN YNNNNNNNNNNNNNNYNNNNNNYYN
          DEANS        OP     5019 DIS 500 KV    DIS            .000         .000      P
          BRANCHBU     OP     SECT 4-5 500 KV    CB             .000         .000      P
          DEANS        OP     SECT 3-4 500 KV    CB             .000         .000      P
          BRANCHBU     L      BRA-DEA  500 KV                   .000         .000      P
          DEANS        OP     SECT 2-4 500 KV    CB             .000         .000      P
          BRANCHBU     OP     5019     500 KV    DIS            .000         .000      P
          BRANCHBU     OP     SECT 3-4 500 KV    CB             .000         .000      P
 8530    L230.Mickleton-DelcoTp-Trainer.220-38 + Delco.UnitY Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DELCOTAP     X      1 TR     230 KV                   .000         .000      P
          DELCOTAP     OP     185 CB   230 KV    CB             .000         .000      P
          MICKLETO     OP     BUSGCBV  230 KV    CB             .000         .000      P
          TRAINER      L      DEL-TRA  230 KV                   .000         .000      P
          DELCOTAP     LD     DELC1    230 KV                   .000         .000      P
          DELCOTAP     L      DEL-MIC  230 KV                   .000         .000      P
          MICKLETO     OP     DT       230 KV    CB             .000         .000      P
          TRAINER      OP     875 CB   230 KV    CB             .000         .000      P
          DELCOTAP     U      DELCO    13 KV                    .000         .000      P
 8540    L138.FederalSquare-Newark.G-1359                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NEWARK       OP     SECT 3-6 138 KV    CB             .000         .000      P
          FEDERALS     OP     SECT 1-2 138 KV    CB             .000         .000      P
          NEWARK       L      FED-NEW  138 KV                   .000         .000      P
          NEWARK       X      132-3-T  13 KV                    .000         .000      P
          FEDERALS     OP     132-1    138 KV    CB             .000         .000      P
          NEWARK       X      132-3-P  138 KV                   .000         .000      P
          FEDERALS     LD     LOAD1    138 KV                   .000         .000      P
          NEWARK       OP     132-3    138 KV    DIS            .000         .000      P
          NEWARK       OP     132-3 CB 26 KV     CB             .000         .000      P
          NEWARK       X      132-3-S  26 KV                    .000         .000      P
          NEWARK       OP     132-3 CB 13 KV     CB             .000         .000      P
          FEDERALS     OP     G1359DIS 138 KV    DIS            .000         .000      P
          NEWARK       CL     BUSTIE3  13 KV     CB             .000         .000      P
          NEWARK       CL     BUSTIE23 26 KV     CB             .000         .000      P
 8560    L230.Graceton-FvFrks.110510 + 230/115.Grctn.230-1 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FIVEFORK     OP     110KVTIE 115 KV    CB             .000         .000      P
          FIVEFORK     OP     110511OC 115 KV    CB             .000         .000      P
          GRACETON     OP     230-1CB  230 KV    CB             .000         .000      P
          FIVEFORK     L      FIV-GRA  115 KV                   .000         .000      P
          GRACETON     X      230-1    230 KV                   .000         .000      P
          FIVEFORK     L      FIV-ROC2 115 KV                   .000         .000      P
          GRACETON     OP     2305-1TR 230 KV    CB             .000         .000      P
          FIVEFORK     L      FIV-ROC1 115 KV                   .000         .000      P
          FIVEFORK     OP     110512OC 115 KV    CB             .000         .000      P
 8570    L230.Grnt-Hwrd-Clmbia-HghRdg.2312 + 230/115.Grnt.1Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GRANITE      OP     2311_12  230 KV    CB             .000         .000      P
          HIGHRIDG     OP     2312CB   230 KV    CB             .000         .000      P
          GRANITE      OP     110560-A 115 KV    CB             .000         .000      P
          GRANITE      X      230-1    230 KV                   .000         .000      P
          GRANITE      OP     110527-B 115 KV    CB             .000         .000      P
          HIGHRIDG     OP     2312B43  230 KV    CB             .000         .000      P
          HOWARD       OP     2312 GCB 230 KV    CB             .000         .000      P
          HOWARD       CL     1-2TIE   230 KV    DIS            .000         .000      P
          COLU BC      L      COL-HOW  230 KV                   .000         .000      P
          GRANITE      L      GRA-HOW1 230 KV                   .000         .000      P
          COLU BC      L      COL-HIG  230 KV                   .000         .000      P
          COLU BC      S      2312 SD  230 KV                   .000         .000      P
          COLU BC      OP     2320CB   230 KV    CB             .000         .000      P
 8590    L230.WaughChapel-HighRidge.2316                   Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          HIGHRIDG     OP     23012316 230 KV    CB             .000         .000      P
          WAUGHCHA     OP     2327OCB  230 KV    CB             .000         .000      P
          HIGHRIDG     OP     2316     230 KV    DIS            .000         .000      P
          WAUGHCHA     OP     2327_40  230 KV    CB             .000         .000      P
 8610    230/69.Hosensack.T1                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOSENSAC     OP     TRAN_1-W 230 KV    CB             .000         .000      P
          HOSENSAC     X      1        230 KV                   .000         .000      P
          HOSENSAC     OP     TRAN_1-E 230 KV    CB             .000         .000      P
          HOSENSAC     OP     TRAN_1   69 KV     CB             .000         .000      P
 8630    L230.Grnt-Hwrd-Pmphry-HghRg.2332 + 230/115.Pmphr.1Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HIGHRIDG     OP     23052332 230 KV    CB             .000         .000       
          PUMPHREY     OP     230-1OCB 115 KV    CB             .000         .000       
          GRANITE      OP     2326_32  230 KV    CB             .000         .000       
          PUMPHREY     X      230-1    230 KV                   .000         .000       
          PUMPHREY     OP     519_1TR  115 KV    CB             .000         .000       
          HOWARD       OP     2332 GCB 230 KV    CB             .000         .000       
          HIGHRIDG     L      HIG-HOW  230 KV                   .000         .000       
          GRANITE      L      GRA-HOW3 230 KV                   .000         .000       
          HIGHRIDG     OP     2332A CB 230 KV    CB             .000         .000       
          HOWARD       CL     1-2TIE   230 KV    DIS            .000         .000       
          HOWARD       L      HOW-PUM  230 KV                   .000         .000       
 8640    L230.Essex-NJTMeadows.P-2216 + Kearny.12CT.1-4    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NJTMEADO     OP     SECT 1-2 230 KV    CB             .000         .000       
          KEARNY       OP     NO12GENH 230 KV    DIS            .000         .000       
          KEARNY       U      UN123    13 KV                    .000         .000       
          ESSEX        OP     1-11CB   230 KV    CB             .000         .000       
          NJTMEADO     OP     EASTBREA 230 KV    CB             .000         .000       
          NJTMEADO     CL     LOADTRAN 230 KV    DIS            .000         .000       
          KEARNY       U      UN124    13 KV                    .000         .000       
          KEARNY       U      UN122    13 KV                    .000         .000       
          ESSEX        OP     11-12CB  230 KV    CB             .000         .000       
          ESSEX        L      ESS-KEA  230 KV                   .000         .000       
          KEARNY       X      NO 12XF  230 KV                   .000         .000       
          KEARNY       U      UN121    13 KV                    .000         .000       
          KEARNY       L      KEA-NJT  230 KV                   .000         .000       
 8650    L230.Sayreville-Kilmer-LakeNelson.W-1037          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KILMER       CL     T12TRANS 230 KV    DIS            .000         .000      P
          SAYREVIL     OP     B4       230 KV    CB             .000         .000      P
          KILMER       OP     TRAN T-3 230 KV    DIS            .000         .000      P
          KILMER       OP     TRAN T-1 230 KV    DIS            .000         .000      P
          SAYREVIL     L      KIL-SAYW 230 KV                   .000         .000      P
          KILMER       CL     T34TRANS 230 KV    DIS            .000         .000      P
          KILMER       L      KIL-LAKW 230 KV                   .000         .000      P
          KILMER       OP     W-1037-2 230 KV    DIS            .000         .000      P
          KILMER       OP     W-1037-3 230 KV    DIS            .000         .000      P
          SAYREVIL     OP     B3       230 KV    CB             .000         .000      P
          LAKENELS     OP     W1037 CB 230 KV    CB             .000         .000      P
 8670    L230.Mickleton-Thorofare-EaglePoint.O-2241        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EAGLEPT      OP     102      230 KV    CB             .000         .000      P
          EAGLEPT      L      EAG-THOO 230 KV                   .000         .000      P
          THOROFAR     CL     LOADTRAN 230 KV    DIS            .000         .000      P
          THOROFAR     OP     TRANT-2  230 KV    CB             .000         .000      P
          THOROFAR     OP     O-W      230 KV    CB             .000         .000      P
          EAGLEPT      OP     100      230 KV    CB             .000         .000      P
          EAGLEPT      OP     O-2241   230 KV    DIS            .000         .000      P
          THOROFAR     L      MIC-THO  230 KV                   .000         .000      P
          THOROFAR     U      THOROFSP 230 KV                   .000         .000      P
          MICKLETO     OP     GQ       230 KV    CB             .000         .000      P
          MICKLETO     OP     BV       230 KV    CB             .000         .000      P
 8680    230/69.Mickleton.T4                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MICKLETO     OP     XFMROCBP 69 KV     CB             .000         .000      P
          MICKLETO     X      MICK #4  230 KV                   .000         .000      P
          MICKLETO     OP     EE       230 KV    CB             .000         .000      P
          MICKLETO     OP     MK       230 KV    CB             .000         .000      P
 8690    L230.Roseland-Kearny.M-2318                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WCALDWEL     L      COO-WCAM 230 KV                   .000         .000      P
          COOKRD       L      COO-TURM 230 KV                   .000         .000      P
          TURNPIKE     L      KEA-TURM 230 KV                   .000         .000      P
          KEARNY       OP     3-4      230 KV    CB             .000         .000      P
          WCALDWEL     CL     T3-4TRAN 230 KV    DIS            .000         .000      P
          WCALDWEL     CL     T1-2TRAN 230 KV    DIS            .000         .000      P
          TURNPIKE     CL     LOADTRAN 230 KV    DIS            .000         .000      P
          ROSELAND     OP     17-21    230 KV    CB             .000         .000      P
          WCALDWEL     L      ROS-WCAM 230 KV                   .000         .000      P
          KEARNY       OP     1-3      230 KV    CB             .000         .000      P
          ROSELAND     OP     21-22    230 KV    CB             .000         .000      P
          COOKRD       CL     LOADTRAN 230 KV    DIS            .000         .000      P
 8700    L230.Montour-Milton-Sunbury                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          SUNBURY      OP     MONT     230 KV    CB             .000         .000      P
          MILTON       X      1        230 KV                   .000         .000      P
          MILTON       OP     TRAN_1   69 KV     CB             .000         .000      P
          MONTOUR      OP     SAEGSUNB 230 KV    CB             .000         .000      P
          MONTOUR      OP     SUNB     230 KV    CB             .000         .000      P
          MONTOUR      L      MIL-MON  230 KV                   .000         .000      P
          SUNBURY      L      MIL-SUN  230 KV                   .000         .000      P
 8710    L230.MartinsCreek-MorrisPark-Gilbert.P-2016       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          GILBERT      OP     13P OC   230 KV    CB             .000         .000      P
          MARTINSC     L      MAR-MRP  230 KV                   .000         .000      P
          MORRISPA     OP     BK2 DS   230 KV    DIS            .000         .000      P
          MARTINSC     OP     GBRTMONR 230 KV    CB             .000         .000      P
          GILBERT      L      GIL-MRP  230 KV                   .000         .000      P
          GILBERT      OP     PV OC    230 KV    CB             .000         .000      P
          MARTINSC     OP     GBRT     230 KV    CB             .000         .000      P
          MORRISPA     X      BK2      230 KV                   .000         .000      P
 8720    L230.Hosensack-NBoyertown-SReading.1006           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NBOYERTO     OP     1B92     69 KV     CB             .000         .000      P
          SREADING     OP     B100652  230 KV    CB             .000         .000      P
          SREADING     L      NBO-SRE  230 KV                   .000         .000      P
          HOSENSME     L      HOS-NBO  230 KV                   .000         .000      P
          HOSENSME     OP     100682   230 KV    CB             .000         .000      P
 8730    L230.Roseland-Kingsland.K-2316                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WCALDWEL     CL     T1-2TRAN 230 KV    DIS            .000         .000      P
          ROSELAND     OP     17-19    230 KV    CB             .000         .000      P
          KINGSLAN     L      KIN-WCAK 230 KV                   .000         .000      P
          ROSELAND     L      ROS-WCAK 230 KV                   .000         .000      P
          WCALDWEL     CL     T3-4TRAN 230 KV    DIS            .000         .000      P
          KINGSLAN     CL     DUM      230 KV    DIS            .000         .000      P
          KINGSLAN     OP     T2       230 KV    CB             .000         .000      P
          ROSELAND     OP     19-20    230 KV    CB             .000         .000      P
          KINGSLAN     OP     1-2CB    230 KV    CB             .000         .000      P
 8740    L230.Plymouth Meeting-Whitemarsh-Pulaski.220-41   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WHITEMAR     L      PUL-WHI  230 KV                   .000         .000      P
          PULASKI      OP     785 CB   230 KV    CB             .000         .000      P
          CEDARBRO     OP     2TRLS CB 13 KV     CB             .000         .000      P
          WHITEMAR     OP     417 DIS  230 KV    DIS            .000         .000      P
          PLYMOUTH     L      PLY-WHI  230 KV                   .000         .000      P
          PLYMOUTH     OP     415 CB   230 KV    CB             .000         .000      P
          PULASKI      OP     1TRLS CB 13 KV     CB             .000         .000      P
          WHITEMAR     OP     75 CB    230 KV    CB             .000         .000      P
 8750    L230.Northeast-Riverside.2339                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RIVERSID     OP     2339_44  230 KV    CB             .000         .000      P
          NORTHEAS     L      NOR-RIV9 230 KV                   .000         .000      P
          NORTHEAS     OP     2339CB   230 KV    CB             .000         .000      P
 8760    L230.BrndnShrs-RvrSde.2344 + 230/115.RvrSide.230-1Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RIVERSID     OP     2339_44  230 KV    CB             .000         .000      P
          RIVERSID     OP     230-1OCB 115 KV    CB             .000         .000      P
          RIVERSID     OP     110981   115 KV    CB             .000         .000      P
          RIVERSID     S      115011   115 KV                   .000         .000      P
          NORTHPT      L      NOR-RIV1 115 KV                   .000         .000      P
          NORTHEAS     L      NOR-RIV9 230 KV                   .000         .000      P
          RIVERSID     X      230-1    230 KV                   .000         .000      P
          BRANDONS     OP     2344 OCB 230 KV    CB             .000         .000      P
          BRANDONS     L      BRA-RIV4 230 KV                   .000         .000      P
          BRANDONS     OP     23472344 230 KV    CB             .000         .000      P
 8770    L230.BrandonShores-Riverside.2345                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRANDONS     OP     23450CB  230 KV    CB             .000         .000      P
          BRANDONS     OP     2345_S6  230 KV    CB             .000         .000      P
          RIVERSID     L      BRA-RIV5 230 KV                   .000         .000      P
          RIVERSID     OP     2345OCB  230 KV    CB             .000         .000      P
 8780    230/115.Riverside.T2+L230.Rivsid-BrndShr&Rivsid-NEY Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RIVERSID     OP     110982   115 KV    CB             .000         .000       
          RIVERSID     L      NOR-RIV2 115 KV                   .000         .000       
          RIVERSID     OP     230-2OCB 115 KV    CB             .000         .000       
          RIVERSID     L      NOR-RIV7 230 KV                   .000         .000       
          RIVERSID     OP     2345OCB  230 KV    CB             .000         .000       
          RIVERSID     S      115012   115 KV                   .000         .000       
          BRANDONS     L      BRA-RIV5 230 KV                   .000         .000       
          RIVERSID     OP     2317OCB  230 KV    CB             .000         .000       
          RIVERSID     X      230-2    230 KV                   .000         .000       
 8790    L230.Whitpain-Roxborough-Westmoreland.220-65      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROXBOROU     X      ROX 3TR  230 KV                   .000         .000      P
          ROXBOROU     OP     235 CB   69 KV     CB             .000         .000      P
          WMORELAN     OP     705 CB   230 KV    CB             .000         .000      P
          ROXBOROU     L      ROX-WMO  230 KV                   .000         .000      P
          WHITPAIN     L      ROX-WHI  230 KV                   .000         .000      P
          WMORELAN     X      11TR     230 KV                   .000         .000      P
          WHITPAIN     OP     655 CB   230 KV    CB             .000         .000      P
 8800    L230.NorthPhiladelphia-Westmoreland.220-77        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NPHILADE     L      NPH-WMO  230 KV                   .000         .000      P
          WMORELAN     X      13TR     230 KV                   .000         .000      P
          NPHILADE     OP     655 CB   230 KV    CB             .000         .000      P
          WMORELAN     OP     905 CB   230 KV    CB             .000         .000      P
 8810    L230.HomerCity-Shelocta-Keystone.2014             Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNYYN YNNYNNNNNNNNNNNNNNNNNNYYN
          KEYSTONE     OP     10       230 KV    CB             .000         .000      P
          KEYSTONE     L      KEY-SHE  230 KV                   .000         .000      P
          HOMERCIT     L      HOM-SHE  230 KV                   .000         .000      P
          HOMERCIT     OP     209      230 KV    CB             .000         .000      P
          KEYSTONE     OP     20       230 KV    CB             .000         .000      P
          SHELOCTA     X      NO2      230 KV                   .000         .000      P
          HOMERCIT     OP     208      230 KV    CB             .000         .000      P
          SHELOCTA     OP     NO2TX115 115 KV    CB             .000         .000      P
 8820    DBL: L230.HomerCity-Shelocta-Keyston + Keystone.U1Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          KEYSTONE     U      UNIT 1   20 KV                    .000         .000      P
          HOMERCIT     L      HOM-SHE  230 KV                   .000         .000      P
          HOMERCIT     OP     209      230 KV    CB             .000         .000      P
          KEYSTONE     OP     20       230 KV    CB             .000         .000      P
          KEYSTONE     OP     10       230 KV    CB             .000         .000      P
          KEYSTONE     L      KEY-SHE  230 KV                   .000         .000      P
          SHELOCTA     OP     NO2TX115 115 KV    CB             .000         .000      P
          HOMERCIT     OP     208      230 KV    CB             .000         .000      P
          SHELOCTA     X      NO2      230 KV                   .000         .000      P
          KEYSTONE     OP     B4       500 KV    CB             .000         .000      P
          KEYSTONE     X      BK 1 50  500 KV                   .000         .000      P
          KEYSTONE     OP     B5       500 KV    CB             .000         .000      P
 8830    STEELTN-HUMMLSTWN-MIDDLTOWN JCT (1002) 230 KV LINEY Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STEELTON     OP     HUMM     230 KV    CB             .000         .000      P
          STEELTON     OP     TRAN_1SF 230 KV    CB             .000         .000      P
          MIDDLJCT     OP     B22      230 KV    CB             .000         .000      P
          HUMMETAP     L      HUM-MID2 230 KV                   .000         .000      P
          HUMMETAP     L      HUM-HUM  230 KV                   .000         .000      P
          HUMMELST     OP     SDMIJUSF 230 KV    CB             .000         .000      P
          HUMMETAP     L      HUM-STE  230 KV                   .000         .000      P
 8840    L230.Burtonsville-Bowie.23044                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BOWIE        L      BOW-BUR4 230 KV                   .000         .000      P
          BOWIE        OP     23044B   230 KV    CB             .000         .000      P
          BURTONSV     OP     23044B   230 KV    CB             .000         .000      P
 8850    L230.Burtonsville-Bowie.23043                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BOWIE        OP     23043B   230 KV    CB             .000         .000      P
          BOWIE        L      BOW-BUR3 230 KV                   .000         .000      P
          BURTONSV     OP     23043B   230 KV    CB             .000         .000      P
 8860    L230.Conowingo-Nottingham-220-03&Conowingo.U8-U11 Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          NOTTINGH     L      CON-NOT  230 KV                   .000         .000      P
          CONOWING     U      GEN8     13 KV                    .000         .000      P
          CONOWING     U      GEN9     13 KV                    .000         .000      P
          CONOWING     OP     220-03CB 230 KV    CB             .000         .000      P
          CONOWING     X      CONO6TR  230 KV                   .000         .000      P
          CONOWING     U      G11      13 KV                    .000         .000      P
          NOTTINGH     OP     035      230 KV    CB             .000         .000      P
          CONOWING     X      CONO5TR  230 KV                   .000         .000      P
          CONOWING     U      G10      13 KV                    .000         .000      P
 8870    L230.Conowingo-Nottingham-220-03                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          NOTTINGH     OP     035      230 KV    CB             .000         .000      P
          CONOWING     L      CON-NOT  230 KV                   .000         .000      P
          CONOWING     OP     220-03CB 230 KV    CB             .000         .000      P
 8880    L230.Limerick-Cromby-Betzwood.220-61/63           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          CROMBY       X      CROM7TR  230 KV                   .000         .000      P
          CROMBY       X      CROM5TR  230 KV                   .000         .000      P
          CROMBY       OP     455 CB   69 KV     CB             .000         .000      P
          CROMBY       OP     575 CB   230 KV    CB             .000         .000      P
          CROMBY       OP     615 CB   230 KV    CB             .000         .000      P
          LIMERICK     L      CRO-LIM1 230 KV                   .000         .000      P
          BETZWOOD     OP     635      230 KV    CB             .000         .000      P
          CROMBY       OP     75       35 KV     CB             .000         .000      P
          BETZWOOD     L      BET-CRO  230 KV                   .000         .000      P
 8890    L230.NewFreedom-Marlton-CoxsCorner.W-2223         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MARLTON      CL     T1-2TRAN 230 KV    DIS            .000         .000      P
          NEWFREED     OP     11_12    230 KV    CB             .000         .000      P
          NEWFREED     L      MAR-NEW  230 KV                   .000         .000      P
          NEWFREED     OP     230 2-12 230 KV    CB             .000         .000      P
          COXSCORN     L      COX-MARW 230 KV                   .000         .000      P
          COXSCORN     OP     SECT3-4  230 KV    CB             .000         .000      P
          MARLTON      CL     T3-4TRAN 230 KV    DIS            .000         .000      P
          COXSCORN     OP     SECT1-3  230 KV    CB             .000         .000      P
 8900    L230.Croydon-Burlington.D-220-30                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BURLINGT     OP     2-5      230 KV    CB             .000         .000      P
          BURLINGT     L      BUR-CRO  230 KV                   .000         .000      P
          CROYDON      OP     115 CB   230 KV    CB             .000         .000      P
          CROYDON      OP     215 CB   230 KV    CB             .000         .000      P
          BURLINGT     OP     1-5      230 KV    CB             .000         .000      P
 8910    L230.Essex-Hudson.A-2227                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HUDSON       OP     5-6      230 KV    CB             .000         .000      P
          ESSEX        L      ESS-HUD  230 KV                   .000         .000      P
          ESSEX        OP     13-14CB  230 KV    CB             .000         .000      P
          ESSEX        OP     2-14CB   230 KV    CB             .000         .000      P
          HUDSON       OP     1-5      230 KV    CB             .000         .000      P
 8920    L230.Smithburg-EastWindsor.E-2005                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SMITHBUR     L      EWI-SMI  230 KV                   .000         .000      P
          EWINDSOR     OP     B40      230 KV    CB             .000         .000      P
          SMITHBUR     OP     ED GC    230 KV    CB             .000         .000      P
          SMITHBUR     OP     EB GC    230 KV    CB             .000         .000      P
          EWINDSOR     OP     FE       230 KV    CB             .000         .000      P
 8930    L230.EastWindsor-Windsor.F-2006                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EWINDSOR     OP     FE       230 KV    CB             .000         .000      P
          WIND JC      OP     FC       230 KV    CB             .000         .000      P
          EWINDSOR     OP     2F       230 KV    CB             .000         .000      P
          WIND JC      OP     BK3LSD   35 KV     CB             .000         .000      P
          EWINDSOR     L      EWI-WIN  230 KV                   .000         .000      P
          WIND JC      X      BK 3TR   230 KV                   .000         .000      P
 8940    L230.Lackawanna-Oxbow-N.Meshoppen                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          NMESHOPP     L      NME-OXB  230 KV                   .000         .000      P
          LACKAWAN     OP     NMESH_E  230 KV    CB             .000         .000      P
          NMESHOPP     OP     B22      230 KV    CB             .000         .000      P
          NMESHOPP     OP     B19      230 KV    CB             .000         .000      P
          LACKAWAN     OP     NMESH_W  230 KV    CB             .000         .000      P
          LACKAWAN     L      LAC-OXB  230 KV                   .000         .000      P
 8950    Linden.U5&U6                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LINDEN       U      UNIT05   13 KV                    .000         .000      P
          LINDEN       U      UNIT06   13 KV                    .000         .000      P
          LINDEN       OP     3-4      230 KV    CB             .000         .000      P
          LINDEN       OP     1-3      230 KV    CB             .000         .000      P
          LINDEN       X      BK 56-P  230 KV                   .000         .000      P
 8960    Orchards-Center (110589) 115 kV line              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CENTER       OP     555589GC 115 KV    CB             .000         .000      P
          CENTER       CL     BUSTIE   13 KV     CB             .000         .000      P
          ORCHARDS     OP     110589   115 KV    CB             .000         .000      P
          CENTER       OP     DUM3LSBK 13 KV     CB             .000         .000      P
          ORCHARDS     OP     589_598  115 KV    CB             .000         .000      P
          CENTER       X      110-3    115 KV                   .000         .000      P
          CENTER       OP     552589CB 115 KV    CB             .000         .000      P
          CENTER       L      CEN-ORC9 115 KV                   .000         .000      P
 8970    L230.Northeast-RaphaelRoad.2315                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NORTHEAS     OP     2315CB   230 KV    CB             .000         .000      P
          RAPHAERD     OP     2305_15  230 KV    CB             .000         .000      P
          NORTHEAS     L      NOR-RAP5 230 KV                   .000         .000      P
          RAPHAERD     OP     2315     230 KV    CB             .000         .000      P
 8980    L115.Northeast-WindyEdge.110581                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HONEYGO      L      GEN-HON1 115 KV                   .000         .000      P
          NORTHEAS     OP     110581   115 KV    CB             .000         .000      P
          GENMOTOR     OP     SW110581 115 KV    DIS            .000         .000      P
          HONEYGO      L      HON-WIN1 115 KV                   .000         .000      P
          WINDYEDG     OP     110581   115 KV    CB             .000         .000      P
          NORTHEAS     OP     1101-581 115 KV    CB             .000         .000      P
          GENMOTOR     OP     DUM3     115 KV    DIS            .000         .000      P
          GENMOTOR     L      GEN-NOR1 115 KV                   .000         .000      P
 8990    L115.Northeast-WindyEdge.110582                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GENMOTOR     OP     SW110582 115 KV    DIS            .000         .000      P
          HONEYGO      L      GEN-HON2 115 KV                   .000         .000      P
          WINDYEDG     OP     110582   115 KV    CB             .000         .000      P
          HONEYGO      L      HON-WIN2 115 KV                   .000         .000      P
          NORTHEAS     OP     582_-3   115 KV    CB             .000         .000      P
          NORTHEAS     OP     582_-2   115 KV    CB             .000         .000      P
          GENMOTOR     L      GEN-NOR2 115 KV                   .000         .000      P
 9000    L345.Waldwick-SouthMahwah-Ramapo.J-3410/69        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RAMAPO       OP     69-2Y    345 KV    CB             .000         .000       
          RAMAPO       OP     2500-69  345 KV    CB             .000         .000       
          WALDWICK     OP     345SC5-6 345 KV    CB             .000         .000       
          SMAWA        OP     69DIS    345 KV    DIS            .000         .000       
          WALDWICK     L      SMA-WALJ 345 KV                   .000         .000       
          SMAWA        X      BK258    345 KV                   .000         .000       
          RAMAPO       L      RAM-SMA9 345 KV                   .000         .000       
          WALDWICK     OP     345SC1-5 345 KV    CB             .000         .000       
          WALDWICK     OP     J-3410   345 KV    DIS            .000         .000       
          SMAWA        OP     T258_J34 345 KV    CB             .000         .000       
          SMAWA        OP     J_3410   345 KV    DIS            .000         .000       
 9010    L345.Waldwick-SouthMahwah-Ramapo.K-3411/70        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RAMAPO       L      RAM-SMA0 345 KV                   .000         .000      P
          RAMAPO       OP     T-70-2   345 KV    CB             .000         .000      P
          WALDWICK     OP     345SC1-7 345 KV    CB             .000         .000      P
          WALDWICK     OP     345SC7-8 345 KV    CB             .000         .000      P
          WALDWICK     L      SMA-WALK 345 KV                   .000         .000      P
          RAMAPO       OP     70-2Y    345 KV    CB             .000         .000      P
 9020    Westport-Center (110552) 115 kV line              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WESTPORT     OP     10552TIE 115 KV    CB             .000         .000      P
          CENTER       OP     552556OC 115 KV    CB             .000         .000      P
          CENTER       X      110-2    115 KV                   .000         .000      P
          CENTER       CL     BUSTIE   13 KV     CB             .000         .000      P
          CENTER       L      CEN-WES2 115 KV                   .000         .000      P
          CENTER       OP     DUM2LSBK 13 KV     CB             .000         .000      P
          WESTPORT     OP     110552   115 KV    CB             .000         .000      P
          WESTPORT     OP     525LN DS 115 KV    DIS            .000         .000      P
          CENTER       OP     552589CB 115 KV    CB             .000         .000      P
 9030    L138.Trenton-USSteel-Biles.A-130-27               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STEELTAP     L      STE-TRE  138 KV                   .000         .000      P
          TRENTON      OP     SECT6-7  138 KV    CB             .000         .000      P
          TRENTON      OP     SECT7-8  138 KV    CB             .000         .000      P
          BILES        L      BIL-STE2 138 KV                   .000         .000      P
          STEELTAP     OP     30       138 KV    CB             .000         .000      P
          BILES        OP     20       138 KV    CB             .000         .000      P
 9040    L230.Cookstown-VanHise-Larrabee-Whitings.B1042    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          VANHISVI     L      COO-VAN1 230 KV                   .000         .000      P
          COOKSTOW     OP     B39      230 KV    CB             .000         .000      P
          MANCHEST     L      MAN-WHI1 230 KV                   .000         .000      P
          WHITINGS     OP     B1042    230 KV    DIS            .000         .000      P
          WHITINGS     X      BANK 5TR 230 KV                   .000         .000      P
          COOKSTOW     OP     B69      230 KV    CB             .000         .000      P
          VANHISVI     L      MAN-VAN1 230 KV                   .000         .000      P
          LARRABEE     OP     B90      230 KV    CB             .000         .000      P
          VANHISVI     L      LAR-VAN1 230 KV                   .000         .000      P
          LARRABEE     OP     B93      230 KV    CB             .000         .000      P
          MANCHEST     LD     MANCHEST 230 KV                   .000         .000      P
          WHITINGS     OP     BK 5 CS  230 KV    DIS            .000         .000      P
          WHITINGS     OP     BV GC    230 KV    CB             .000         .000      P
 9050    230/69.SilverLake.T2                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SILVERLA     OP     XFMROCBL 69 KV     CB             .000         .000      P
          SILVERLA     X      SILV #2  230 KV                   .000         .000      P
          SILVERLA     OP     OCB C    230 KV    CB             .000         .000      P
 9060    L230.Morgantown-Hawkins-KelsonRidge.23076/84      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MORGANTO     OP     9BB      230 KV    CB             .000         .000      P
          HAWKINS      L      HAW-KEL  230 KV                   .000         .000      P
          MORGANTO     OP     9CB      230 KV    CB             .000         .000      P
          HAWKINS      L      HAW-MOR6 230 KV                   .000         .000      P
          KELSONRI     OP     1C       230 KV    CB             .000         .000      P
          KELSONRI     OP     1D       230 KV    CB             .000         .000      P
          HAWKINS      L      HAW-HAW4 230 KV                   .000         .000      P
 9070    L230.CedarGrove-CedarSub-William.F-2206           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CEDARSUB     CL     LOADTRAN 230 KV    DIS            .000         .000      P
          CEDARGRO     OP     3-4      230 KV    CB             .000         .000      P
          CEDARGRO     L      CED-CEDF 230 KV                   .000         .000      P
          CEDARSUB     L      CED-WILF 230 KV                   .000         .000      P
          WILLIAM1     OP     SC3-4CB  230 KV    CB             .000         .000      P
          CEDARGRO     OP     1-3      230 KV    CB             .000         .000      P
          WILLIAM1     OP     SC2-3CB  230 KV    CB             .000         .000      P
 9080    L230.Limerick-Cromby-UpperProvidence.220-60/62    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          UPPERPRO     L      CRO-UPP  230 KV                   .000         .000      P
          CROMBY       X      CROM6TR  230 KV                   .000         .000      P
          LIMERICK     L      CRO-LIM0 230 KV                   .000         .000      P
          UPPERPRO     OP     625      230 KV    CB             .000         .000      P
          CROMBY       OP     365 CB   69 KV     CB             .000         .000      P
          CROMBY       OP     605 CB   230 KV    CB             .000         .000      P
 9110    L230.Cumberland-Juniata + 230/69.Cumberland.T2    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JUNIATA      OP     CUMB_1   230 KV    CB             .000         .000      P
          CUMB PL      L      CUM-JUN  230 KV                   .000         .000      P
          CUMB PL      OP     JUNI_1   230 KV    CB             .000         .000      P
          CUMB PL      OP     TRAN_2   69 KV     CB             .000         .000      P
          CUMB PL      X      2        230 KV                   .000         .000      P
 9120    500/230.ChalkPoint.T5                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHALKPT      X      500-5T   500 KV                   .000         .000      P
          CHALKPT      OP     10BB     500 KV    CB             .000         .000      P
          CHALKPT      OP     7BB      230 KV    CB             .000         .000      P
          CHALKPT      OP     7AB      230 KV    CB             .000         .000      P
          CHALKPT      OP     10CB     500 KV    CB             .000         .000      P
 9130    500/230.ChalkPoint.T6                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHALKPT      OP     8BB      230 KV    CB             .000         .000      P
          CHALKPT      OP     8AB      230 KV    CB             .000         .000      P
          CHALKPT      OP     11BB     500 KV    CB             .000         .000      P
          CHALKPT      OP     11CB     500 KV    CB             .000         .000      P
          CHALKPT      X      500-6T   500 KV                   .000         .000      P
 9140    L230.DickersonH-QuinceOrchard.23034               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DICKERSH     OP     44B      230 KV    CB             .000         .000      P
          DICKERSH     OP     44C      230 KV    CB             .000         .000      P
          QUINCEOR     OP     23034B   230 KV    CB             .000         .000      P
          DICKERSH     L      DIC-QUI4 230 KV                   .000         .000      P
 9150    L230.QuinceOrchard-BellsMillRoad.23030            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          QUINCEOR     X      118-3T   230 KV                   .000         .000      P
          BELLSMIL     X      121-3T   230 KV                   .000         .000      P
          QUINCEOR     OP     23025B   230 KV    CB             .000         .000      P
          QUINCEOR     OP     23035B   230 KV    CB             .000         .000      P
          BELLSMIL     OP     12TS2B   69 KV     CB             .000         .000      P
          QUINCEOR     OP     69K7B    69 KV     CB             .000         .000      P
          BELLSMIL     X      121-12T  230 KV                   .000         .000      P
          BELLSMIL     OP     138K1    138 KV    CB             .000         .000      P
          BELLSMIL     OP     138K3    138 KV    CB             .000         .000      P
          BELLSMIL     OP     12TS3B   69 KV     CB             .000         .000      P
          QUINCEOR     OP     69K8B    69 KV     CB             .000         .000      P
          BELLSMIL     CP     3 CAP    230 KV                   .000         .000      P
          BELLSMIL     L      BEL-QUI0 230 KV                   .000         .000      P
 9160    L230.BurchHill-OakGrove-Talbert-KelsnRdge.68/86/81Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OAKGROVE     OP     9BB      230 KV    CB             .000         .000      P
          BURCHESH     OP     1BB      230 KV    CB             .000         .000      P
          BURCHESH     OP     1CB      230 KV    CB             .000         .000      P
          TALBERT      L      BUR-TAL1 230 KV                   .000         .000      P
          KELSONRI     OP     2A       230 KV    CB             .000         .000      P
          OAKGROVE     OP     9CB      230 KV    CB             .000         .000      P
          KELSONRI     L      KEL-TAL  230 KV                   .000         .000      P
          KELSONRI     OP     2B       230 KV    CB             .000         .000      P
          OAKGROVE     L      OAK-TAL8 230 KV                   .000         .000      P
 9170    L230.Morgantwn-Talbert-OakGrove-BurchHill.85/67/82Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MORGANTO     OP     6CB      230 KV    CB             .000         .000      P
          OAKGROVE     OP     7AB      230 KV    CB             .000         .000      P
          BURCHESH     OP     2CB      230 KV    CB             .000         .000      P
          TALBERT      L      MOR-TAL5 230 KV                   .000         .000      P
          TALBERT      L      BUR-TAL2 230 KV                   .000         .000      P
          BURCHESH     OP     2BB      230 KV    CB             .000         .000      P
          MORGANTO     OP     6BB      230 KV    CB             .000         .000      P
          OAKGROVE     L      OAK-TAL7 230 KV                   .000         .000      P
          OAKGROVE     OP     7CB      230 KV    CB             .000         .000      P
 9180    L345.ErieWest-Ashtabula-Perry                     Y Y Y S Y Y N N     YNNYNNNNYNNNNNNNNNNNNNYYN YNNYNNNNYNNNNNNNNNNNNNYYN
          ERIEW        OP     B7       345 KV    CB             .000         .000      P
          PERRY_FE     OP     S621     345 KV    CB             .000         .000      P
          ASHTABUL     L      PER-ASH1 345 KV                   .000         .000      P
          ASHTABUL     OP     DUM18014 345 KV    DIS            .000         .000      P
          ERIEW        OP     B8       345 KV    CB             .000         .000      P
          ERIEW        L      ASH-ERI  345 KV                   .000         .000      P
          ASHTABUL     X      TR-8     345 KV                   .000         .000      P
          ASHTABUL     OP     B1       345 KV    CB             .000         .000      P
          ERIEW        OP     DUMASH   345 KV    DIS            .000         .000      P
          ASHTABUL     OP     DUMPER   345 KV    DIS            .000         .000      P
          PERRY_FE     OP     S620     345 KV    CB             .000         .000      P
 9190    345/115.ErieWest.T1                               Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNNYN YNNYNNNNNNNNNNNNNNNNNNNYN
          ERIEW        OP     B60      345 KV    CB             .000         .000      P
          ERIEW        OP     B5       345 KV    CB             .000         .000      P
          ERIEW        OP     CS30     345 KV    DIS            .000         .000      P
          ERIEW        OP     B54      115 KV    CB             .000         .000      P
          ERIEW        X      NO1 TX   345 KV                   .000         .000      P
 9200    L345.ErieWest-Ashtabula-Perry + Relay.Warren      Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          ASHTABUL     L      PER-ASH1 345 KV                   .000         .000      P
          ERIEW        OP     B8       345 KV    CB             .000         .000      P
          WARREN       OP     B32      115 KV    CB             .000         .000      P
          ASHTABUL     OP     B1       345 KV    CB             .000         .000      P
          ERIEW        L      ASH-ERI  345 KV                   .000         .000      P
          PERRY_FE     OP     S620     345 KV    CB             .000         .000      P
          ASHTABUL     X      TR-8     345 KV                   .000         .000      P
          WARREN       L      FAL-WAR  115 KV                   .000         .000      P
          PERRY_FE     OP     S621     345 KV    CB             .000         .000      P
          ERIEW        OP     B7       345 KV    CB             .000         .000      P
 9210    BURMA-PINEY & BURMA TRANSFORMER                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BURMA        OP     PINEY138 138 KV    CB             .000         .000      P
          PINEY        OP     BURMA115 115 KV    CB             .000         .000      P
          PINEY        OP     BURMAAX  115 KV    CB             .000         .000      P
          BURMA        X      T1       138 KV                   .000         .000      P
          BURMA        L      BUR-PIN  115 KV                   .000         .000      P
 9220    NORTH MESHOPPEN-LENOX                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LENOX        OP     N MESHOP 115 KV    CB             .000         .000      P
          NMESHOPP     L      LEN-NME  115 KV                   .000         .000      P
          NMESHOPP     OP     LENOX115 115 KV    CB             .000         .000      P
 9230    MAYWOOD-NEW MILFORD(J-2236) 230 LINE              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MAYWOOD      OP     SECT 1-2 230 KV    CB             .000         .000      P
          MAYWOOD      OP     TRAN T-1 230 KV    DIS            .000         .000      P
          NEWMILFR     OP     9-10     230 KV    CB             .000         .000      P
          NEWMILFR     OP     SECT2-10 230 KV    CB             .000         .000      P
          NEWMILFR     L      MAY-NEW  230 KV                   .000         .000      P
          MAYWOOD      OP     TRAN T-3 230 KV    DIS            .000         .000      P
 9250    L230.Kittatinny-Newton.T2298                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          KITTATIN     OP     TK AC    230 KV    CB             .000         .000      P
          NEWTON       L      KIT-NEW  230 KV                   .000         .000      P
          KITTATIN     OP     VT AC    230 KV    CB             .000         .000      P
          NEWTON       OP     NT GC    230 KV    CB             .000         .000      P
          NEWTON       X      BK1      230 KV                   .000         .000      P
 9260    S.Waterfrnt-Newprt-Penhrn-Hudsn (Newprt DIS Clsd) Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          HUDSON       OP     9-10     230 KV    CB             .000         .000       
          SWATERFR     OP     SECT 7-8 230 KV    CB             .000         .000       
          NEWP PS      OP     TRANT2   230 KV    DIS            .000         .000       
          HOBOKEN      L      HOB-NEWY 230 KV                   .000         .000       
          SWATERFR     OP     SEC5RCTR 230 KV    CB             .000         .000       
          SWATERFR     OP     SECT 6-7 230 KV    CB             .000         .000       
          NEWP PS      OP     T-2220   230 KV    DIS            .000         .000       
          SWATERFR     OP     SECT 4-5 230 KV    CB             .000         .000       
          HOBOKEN      L      49T-HOB  230 KV                   .000         .000       
          PENHORN      CL     LOADTRAN 230 KV    DIS            .000         .000       
          PENHORN      OP     TRAN2    230 KV    CB             .000         .000       
          HUDSON       L      HUD-PENY 230 KV                   .000         .000       
          SWATERFR     L      NEW-SWAL 230 KV                   .000         .000       
          HOBOKEN      OP     TRANT2AB 230 KV    DIS            .000         .000       
          HOBOKEN      OP     TRANT4AB 230 KV    DIS            .000         .000       
          HUDSON       OP     3-10     230 KV    CB             .000         .000       
          NEWP PS      L      NEW-SWAQ 230 KV                   .000         .000       
          SWATERFR     OP     SECT 5-6 230 KV    CB             .000         .000       
 9270    L230.Hudson-Penhorn-Homestead-NBergen.X-2250      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HUDSON       L      HUD-PENT 230 KV                   .000         .000       
          BERGEN       OP     4-18     230 KV    CB             .000         .000       
          PENHORN      CL     LOADTRAN 230 KV    DIS            .000         .000       
          HOMESTEA     OP     TRAN2    230 KV    CB             .000         .000       
          BERGEN       OP     17-18    230 KV    CB             .000         .000       
          HOMESTEA     OP     TRAN4    230 KV    CB             .000         .000       
          PENHORN      OP     TRAN1    230 KV    CB             .000         .000       
          HOMESTEA     L      HOM-PEN2 230 KV                   .000         .000       
          HOMESTEA     L      HOM-NBE  230 KV                   .000         .000       
          HUDSON       OP     13-14    230 KV    CB             .000         .000       
          NBERGEN      OP     TRAN T-1 230 KV    DIS            .000         .000       
          BERGEN       L      BER-NBE  230 KV                   .000         .000       
          HUDSON       OP     2-13     230 KV    CB             .000         .000       
 9280    L230.PleasantValley-Rocktown.Z-2357               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PLVY PS      OP     SECT1-2  230 KV    CB             .000         .000      P
          ROCKTOWN     L      PLVY-ROC 230 KV                   .000         .000      P
          PLVY PS      OP     SECT2-3  230 KV    CB             .000         .000      P
          ROCKTOWN     OP     B5       230 KV    CB             .000         .000      P
          ROCKTOWN     OP     B9       230 KV    CB             .000         .000      P
 9290    L230.Pohatcong-Kittatinny.L2012                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          KITTATIN     OP     LV AC    230 KV    CB             .000         .000      P
          POHATCON     OP     AL OC    230 KV    CB             .000         .000      P
          KITTATIN     OP     ML AC    230 KV    CB             .000         .000      P
          POHATCON     OP     BK-1     230 KV    DIS            .000         .000      P
          POHATCON     OP     DUM02    34.5 KV   DIS            .000         .000      P
          POHATCON     OP     DUM01    34.5 KV   DIS            .000         .000      P
          POHATCON     X      TR1      230 KV                   .000         .000      P
          KITTATIN     L      KIT-POH  230 KV                   .000         .000      P
 9300    L500.Keeney-RedLion.5036                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNYYN YNNNNNNNNNNNNNNYNNNNNNYYN
          REDLION      OP     501      500 KV    CB             .000         .000       
          REDLION      OP     5036_L2  500 KV    DIS            .000         .000       
          KEENEY       OP     503      500 KV    CB             .000         .000       
          KEENEY       OP     508      500 KV    CB             .000         .000       
          KEENEY       OP     5036-L1  500 KV    CB             .000         .000       
          KEENEY       L      KEE-RED  500 KV                   .000         .000       
          REDLION      OP     502      500 KV    CB             .000         .000       
 9310    L230.WaughChapel-BrandonShores.2342               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WAUGHCHA     OP     230-1_42 230 KV    CB             .000         .000       
          BRANDONS     OP     2342 OCB 230 KV    CB             .000         .000       
          BRANDONS     OP     23422392 230 KV    CB             .000         .000       
          WAUGHCHA     OP     2342OCB  230 KV    CB             .000         .000       
          BRANDONS     L      BRA-WAU2 230 KV                   .000         .000       
 9320    L230.BrandonShores-WaughChapel.2343               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRANDONS     OP     2343 OCB 230 KV    CB             .000         .000      P
          WAUGHCHA     OP     2343OCB  230 KV    CB             .000         .000      P
          WAUGHCHA     OP     230-3_43 230 KV    CB             .000         .000      P
          BRANDONS     OP     23432391 230 KV    CB             .000         .000      P
          BRANDONS     L      BRA-WAU3 230 KV                   .000         .000      P
 9330    L230.DickersonH-Dickerson.23103                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DICKERSO     OP     6 CB     230 KV    CB             .000         .000      P
          DICKERSO     L      DIC-DIC3 230 KV                   .000         .000      P
          DICKERSH     OP     42A      230 KV    CB             .000         .000      P
 9340    L230.DickersonH-Dickerson.23104                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DICKERSO     OP     5AB      230 KV    CB             .000         .000      P
          DICKERSO     L      DIC-DIC4 230 KV                   .000         .000      P
          DICKERSH     OP     42C      230 KV    CB             .000         .000      P
 9350    Farmers Valley-Ridgway 115 kV line                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RIDG PN      OP     FRMRS VL 115 KV    CB             .000         .000      P
          FARMERSV     L      FAR-RID  115 KV                   .000         .000      P
          FARMERSV     OP     RIDGWAY1 115 KV    CB             .000         .000      P
 9360    Farmers Valley-Ridgway & LD shed @ Lewis Run      Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          LEWISRN      OP     A5       115 KV    DIS            .000         .000      P
          RIDG PN      OP     FRMRS VL 115 KV    CB             .000         .000      P
          LEWISRN      OP     1TX MO   115 KV    DIS            .000         .000      P
          FARMERSV     L      FAR-RID  115 KV                   .000         .000      P
          FARMERSV     OP     RIDGWAY1 115 KV    CB             .000         .000      P
 9370    L230.Eldred-Frackvil + 230/69.Eldred.T2&Frackv.T3 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          ELDRED       L      ELD-FRA  230 KV                   .000         .000       
          ELDRED       OP     TRAN_2   69 KV     CB             .000         .000       
          FRACKVIL     X      3        230 KV                   .000         .000       
          ELDRED       X      2        230 KV                   .000         .000       
          FRACKVIL     OP     ELDREDSF 230 KV    CB             .000         .000       
          ELDRED       OP     SUNBLINE 230 KV    CB             .000         .000       
          FRACKVIL     OP     TRAN_3   69 KV     CB             .000         .000       
 9380    CROYDON-CHINA-EMILIE LINE AND EMILIE #6           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHINA        L      CHI-CRO  230 KV                   .000         .000      P
          CHINA        L      CHI-EMI  230 KV                   .000         .000      P
          CROYDON      OP     315 CB   230 KV    CB             .000         .000      P
          EMILIE       X      EMIL6TR  230 KV                   .000         .000      P
          EMILIE       OP     545 CB   230 KV    CB             .000         .000      P
          EMILIE       OP     40 CB    35 KV     CB             .000         .000      P
          CROYDON      OP     215 CB   230 KV    CB             .000         .000      P
 9390    L230.Burtonsville-SandySprings-HighRidge.2334     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SANDYSPG     OP     2334 CB  230 KV    CB             .000         .000       
          HIGHRIDG     OP     2334CB   230 KV    CB             .000         .000       
          HIGHRIDG     OP     23342302 230 KV    CB             .000         .000       
          SANDYSPG     CL     1_2TIE   230 KV    CB             .000         .000       
          BURTONSV     OP     230K46B  230 KV    CB             .000         .000       
          HIGHRIDG     L      HIG-SAN3 230 KV                   .000         .000       
          SANDYSPG     L      BUR-SAN3 230 KV                   .000         .000       
          BURTONSV     OP     230K26B  230 KV    CB             .000         .000       
 9400    L230.HighRidge-SandySprings-Burtonsville.2314     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SANDYSPG     L      BUR-SAN1 230 KV                   .000         .000      P
          HIGHRIDG     L      HIG-SAN1 230 KV                   .000         .000      P
          BURTONSV     OP     230K15B  230 KV    CB             .000         .000      P
          HIGHRIDG     OP     2314CB   230 KV    CB             .000         .000      P
          SANDYSPG     OP     2314 CB  230 KV    CB             .000         .000      P
          SANDYSPG     CL     1_2TIE   230 KV    CB             .000         .000      P
          BURTONSV     OP     230K35B  230 KV    CB             .000         .000      P
          HIGHRIDG     OP     23142304 230 KV    CB             .000         .000      P
 9410    HEATON-JARRETT AND JARRETT 2 TRANSFORMER          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HEATON       OP     785 CB   230 KV    CB             .000         .000      P
          HEATON       OP     755 DIS  230 KV    DIS            .000         .000      P
          HEATON       OP     705 CB   230 KV    CB             .000         .000      P
          JARRET       OP     1-2 CB   13 KV     CB             .000         .000      P
          JARRET       X      JARRET2  230 KV                   .000         .000      P
          JARRET       OP     565 CB   230 KV    CB             .000         .000      P
          HEATON       L      HEA-JAR  230 KV                   .000         .000      P
 9420    L230.Buckingham-Warminster.220-50                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BUCKINGH     L      BUC-WRM  230 KV                   .000         .000      P
          BUCKINGH     X      BUCK5TR  230 KV                   .000         .000      P
          BUCKINGH     OP     210 CB   230 KV    CB             .000         .000      P
          WARMINST     OP     13TRLS C 13 KV     CB             .000         .000      P
          BUCKINGH     OP     50 CB    35 KV     CB             .000         .000      P
          BUCKINGH     OP     35 CS    230 KV    DIS            .000         .000      P
          WARMINST     OP     125 CB   230 KV    CB             .000         .000      P
          WARMINST     X      WRM13TR  230 KV                   .000         .000      P
          WARMINST     X      WRM15TR  230 KV                   .000         .000      P
          BUCKINGH     X      BUCK3TR  230 KV                   .000         .000      P
 9430    L230.Warminster-Heaton.220-57                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WARMINST     OP     125 CB   230 KV    CB             .000         .000      P
          WARMINST     X      WRM16TR  230 KV                   .000         .000      P
          HEATON       OP     905 CB   230 KV    CB             .000         .000      P
          WARMINST     X      WRM14TR  230 KV                   .000         .000      P
          HEATON       L      HEA-WRM  230 KV                   .000         .000      P
          WARMINST     OP     14TRLS C 13 KV     CB             .000         .000      P
 9440    L230.Linden-Tosco.B-2254                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LINDEN       OP     5-6      230 KV    CB             .000         .000      P
          TOSCOCB      OP     BUSTIECB 230 KV    CB             .000         .000      P
          LINDEN       OP     1-5      230 KV    CB             .000         .000      P
          TOSCOCB      OP     CB2      230 KV    CB             .000         .000      P
          TOSCOCB      L      TOS-TOS2 230 KV                   .000         .000      P
          LINDEN       L      LIN-TOS  230 KV                   .000         .000      P
 9450    L230.Tosco-VFT St.2271                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          VFT_ST       OP     1-3      230 KV    CB             .000         .000      P
          TOSCOCB      OP     CB1      230 KV    CB             .000         .000      P
          TOSCOCB      L      TOS-VFT1 230 KV                   .000         .000      P
          VFT_ST       OP     1-2      230 KV    CB             .000         .000      P
          TOSCOCB      OP     BUSTIECB 230 KV    CB             .000         .000      P
 9460    L230.Warinanco-VFT_ST.U-2273                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WARINANC     CL     LOADTRAN 230 KV    DIS            .000         .000      P
          WARINANC     OP     SECT1-2  230 KV    CB             .000         .000      P
          WARINANC     OP     TRAN T-1 230 KV    DIS            .000         .000      P
          WARINANC     L      VFT-WAR1 230 KV                   .000         .000      P
          VFT_ST       OP     1-2      230 KV    CB             .000         .000      P
          VFT_ST       OP     2-3      230 KV    CB             .000         .000      P
 9470    500/230.RedLion.AT50                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          REDLION      OP     503      500 KV    CB             .000         .000      P
          REDLION      X      50       500 KV                   .000         .000      P
          REDLION      OP     233      230 KV    CB             .000         .000      P
          REDLION      OP     234      230 KV    CB             .000         .000      P
          REDLION      OP     502      500 KV    CB             .000         .000      P
 9480    500/230.RedLion.AT51                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          REDLION      X      51       500 KV                   .000         .000      P
          REDLION      OP     240      230 KV    CB             .000         .000      P
          REDLION      OP     501      500 KV    CB             .000         .000      P
          REDLION      OP     505      500 KV    CB             .000         .000      P
 9490    L230.RedLion-Edgemoor.23020 + Edgemoor.HayRd.CC8+3Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDGEMOOR     OP     L1       230 KV    CB             .000         .000      P
          REDLION      OP     242      230 KV    CB             .000         .000      P
          EDGEMOOR     X      T60      230 KV                   .000         .000      P
          EDGEMOOR     U      HAYRD8   18 KV                    .000         .000      P
          EDGEMOOR     LD     SSLD     230 KV                   .000         .000      P
          REDLION      OP     243      230 KV    CB             .000         .000      P
          EDGEMOOR     X      T70      230 KV                   .000         .000      P
          EDGEMOOR     U      HAYRD6   13 KV                    .000         .000      P
          EDGEMOOR     U      HAYRD5   13 KV                    .000         .000      P
          EDGEMOOR     X      T50      230 KV                   .000         .000      P
          EDGEMOOR     L      EDG-RED  230 KV                   .000         .000      P
          EDGEMOOR     X      T80      230 KV                   .000         .000      P
          EDGEMOOR     U      HAYRD7   13 KV                    .000         .000      P
 9500    L230.CoxsCorner-Lumberton.S-2245                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          COXSCORN     L      COX-LUM  230 KV                   .000         .000      P
          LUMBERTO     X      T-220-5  230 KV                   .000         .000      P
          LUMBERTO     CL     T12TRANS 230 KV    DIS            .000         .000      P
          LUMBERTO     OP     3-4      230 KV    CB             .000         .000      P
          LUMBERTO     OP     1-4      230 KV    CB             .000         .000      P
          COXSCORN     OP     SECT3-4  230 KV    CB             .000         .000      P
          COXSCORN     OP     SECT2-4  230 KV    CB             .000         .000      P
          LUMBERTO     OP     220-5LSD 69 KV     DIS            .000         .000      P
 9510    L138.Essex-ECRRF.C-1355 + ECRRF.U1                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ECRRF        OP     SECT 1-2 138 KV    CB             .000         .000      P
          ECRRF        L      ECR-ESS  138 KV                   .000         .000      P
          ESSEX        OP     C1355    138 KV    CB             .000         .000      P
          ECRRF        U      ECRF#1   13 KV                    .000         .000      P
          ECRRF        X      NO 1GSU  138 KV                   .000         .000      P
 9520    TABOR-WAYNE JCT-WANEETA (220-28)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WAYNEJCT     L      WAN-WAY8 230 KV                   .000         .000      P
          TABOR        OP     3TRLS CB 13 KV     CB             .000         .000      P
          TABOR        L      TAB-WAY  230 KV                   .000         .000      P
          TABOR        X      TR 3     230 KV                   .000         .000      P
          TABOR        OP     905 CB   230 KV    CB             .000         .000      P
          WANEETA      OP     285 CB   230 KV    CB             .000         .000      P
          WAYNEJCT     OP     2A CB    230 KV    CB             .000         .000      P
 9530    L138.Bayway-Doremus Place.Q1369                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BAYWAY       OP     SECT 2-3 138 KV    CB             .000         .000       
          DOREMUSP     OP     Q-1369   138 KV    DIS            .000         .000       
          BAYWAY       OP     SECT 3-4 138 KV    CB             .000         .000       
          BAYWAY       L      BAY-DOR  138 KV                   .000         .000       
 9550    Susquehanna.U1&U2 (for TLC)                       Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          SUSQUEHA     X      1        230 KV                   .000         .000      P
          SUSQUEHA     OP     GEN1-W   230 KV    CB             .000         .000      P
          SUSQUEHA     U      UNIT01   24 KV                    .000         .000      P
          SUSQUEHA     OP     GEN_2-S  500 KV    CB             .000         .000      P
          SUSQUEHA     U      UNIT02   24 KV                    .000         .000      P
          SUSQUEHA     OP     GEN_2-N  500 KV    CB             .000         .000      P
          SUSQUEHA     OP     GEN1-E   230 KV    CB             .000         .000      P
          SUSQUEHA     X      2        500 KV                   .000         .000      P
 9560    L230.CedarGrove-JacksonRoad.L-2238                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CEDARGRO     L      CED-JAC  230 KV                   .000         .000       
          CEDARGRO     OP     3-4      230 KV    CB             .000         .000       
          JACK PS      OP     7-8      230 KV    CB             .000         .000       
          CEDARGRO     OP     2-4      230 KV    CB             .000         .000       
          JACK PS      OP     2-8      230 KV    CB             .000         .000       
 9570    HINCHMANS AVE-JACKSON ROAD (M-2239) 230KV LINE    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JACK PS      OP     2-3CB    230 KV    CB             .000         .000      P
          HINCHMAN     L      HIN-JAC  230 KV                   .000         .000      P
          HINCHMAN     OP     SECT 3-4 230 KV    CB             .000         .000      P
          JACK PS      OP     LOADTRAN 230 KV    DIS            .000         .000      P
 9610    Lincoln Jct. 115 kV (Hunterstown-Orrtanna-Lincoln)Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ORRTANNA     OP     96382    115 KV    CB             .000         .000      P
          LINCOJCT     L      LNJ-ORR  115 KV                   .000         .000      P
          LINCOJCT     L      LNJ-LIN  115 KV                   .000         .000      P
          HUNTERST     OP     96392    115 KV    CB             .000         .000      P
          LINCOLN      OP     96362    115 KV    CB             .000         .000      P
          HUNTERST     L      HUN-LNJ  115 KV                   .000         .000      P
 9620    Mountain-Gardners (974) 115 kV line               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GARDNERS     OP     97482    115 KV    CB             .000         .000      P
          MOUN ME      OP     97412    115 KV    CB             .000         .000      P
          GARDNERS     L      GAR-MOU  115 KV                   .000         .000      P
 9630    L115.MiddletownJct-Roundtop.975 (Sctnlz F)        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MIDDLJCT     OP     97542    115 KV    CB             .000         .000      P
          CLY          L      CLY-NEW  115 KV                   .000         .000      P
          NEWBERRY     L      NEW-ROU  115 KV                   .000         .000      P
          COLLINS      L      COL-MID  115 KV                   .000         .000      P
          ROUNDTOP     OP     97572    115 KV    CB             .000         .000      P
          CLY          L      CLY-COL  115 KV                   .000         .000      P
 9640    Roundtop-Allen-PPGI (981) 115 kV line             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PPGI         OP     98122    115 KV    CB             .000         .000      P
          ALLEN        L      ALL-PPG  115 KV                   .000         .000      P
          ALLEN        L      ALL-ROU  115 KV                   .000         .000      P
          ROUNDTOP     OP     98172    115 KV    CB             .000         .000      P
 9650    PPGI-Mountain (982) 115 kV line                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MOUN ME      L      MOU-PPG  115 KV                   .000         .000       
          PPGI         OP     98222    115 KV    CB             .000         .000       
          MOUN ME      OP     98212    115 KV    CB             .000         .000       
 9660    Hunterstown-TexasEastern-Gardners (991) 115 kV linY Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HUNTERST     L      TEX-HUN  115 KV                   .000         .000      P
          TEXSEAST     LD     TEXSEAST 115 KV                   .000         .000      P
          HUNTERST     OP     99192CB  115 KV    CB             .000         .000      P
          GARDNERS     L      GAR-TEX  115 KV                   .000         .000      P
          GARDNERS     OP     99182    115 KV    CB             .000         .000      P
 9670    Lincoln-Straban-Germantown (998) 115 kV line      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GERMANTO     L      GER-STR  115 KV                   .000         .000      P
          GERMANTO     OP     99842    115 KV    CB             .000         .000      P
          LINCOLN      L      LIN-STR  115 KV                   .000         .000      P
          LINCOLN      OP     99862    115 KV    CB             .000         .000      P
 9680    Hunterstown-Lincoln (962) 115 kV line             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LINCOLN      OP     96262-1  115 KV    CB             .000         .000      P
          HUNTERST     L      HUN-LIN  115 KV                   .000         .000      P
          HUNTERST     OP     96292    115 KV    CB             .000         .000      P
 9690    Gardners-Roundtop (973) 115 kV line               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DILLSBUR     L      DIL-GAR  115 KV                   .000         .000      P
          GARDNERS     OP     97382    115 KV    CB             .000         .000      P
          DILLSBUR     L      DIL-ROU  115 KV                   .000         .000      P
          ROUNDTOP     OP     97372    115 KV    CB             .000         .000      P
 9700    Orrtanna CT                                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ORRTANNA     OP     B384     115 KV    CB             .000         .000      P
          ORRTANNA     U      ORRTAN   13 KV                    .000         .000      P
          ORRTANNA     X      3 TX 11  115 KV                   .000         .000      P
 9710    Mountain #1 CT                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MOUN ME      U      GEN #1   13 KV                    .000         .000      P
 9720    Mountain #2 CT                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MOUN ME      U      GEN #2   13 KV                    .000         .000      P
 9730    230/115.MiddletownJct.T1&T3.+230.Bus4             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          MIDDLJCT     OP     B1-44    230 KV    CB             .000         .000      P
          MIDDLJCT     X      3 BANK   230 KV                   .000         .000      P
          MIDDLJCT     L      HUM-MID8 230 KV                   .000         .000      P
          MIDDLJCT     L      BRU-MID5 230 KV                   .000         .000      P
          MIDDLJCT     L      MID-TMI1 230 KV                   .000         .000      P
          MIDDLJCT     OP     100542   230 KV    CB             .000         .000      P
          MIDDLJCT     OP     109142   230 KV    CB             .000         .000      P
          MIDDLJCT     OP     100442   230 KV    CB             .000         .000      P
          MIDDLJCT     OP     B3-44    230 KV    CB             .000         .000      P
          MIDDLJCT     OP     B8       230 KV    CB             .000         .000      P
          MIDDLJCT     X      1 BANK-P 230 KV                   .000         .000      P
          MIDDLJCT     OP     GENDUMMY 69 KV     CB             .000         .000      P
          MIDDLJCT     OP     109842   230 KV    CB             .000         .000      P
          MIDDLJCT     OP     B19      230 KV    CB             .000         .000      P
          MIDDLJCT     OP     B2-44    230 KV    CB             .000         .000      P
          MIDDLJCT     OP     1B82     115 KV    CB             .000         .000      P
 9740    Middletown Jct #5 230/115 kV XF and BUS #8        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MIDDLJCT     OP     5B82     115 KV    CB             .000         .000      P
          MIDDLJCT     OP     B16      230 KV    CB             .000         .000      P
          MIDDLJCT     OP     109282   230 KV    CB             .000         .000      P
          BRUNNERI     L      BRU-MID6 230 KV                   .000         .000      P
          MIDDLJCT     X      5 BANK-P 230 KV                   .000         .000      P
          MIDDLJCT     OP     105682   230 KV    CB             .000         .000      P
          MIDDLJCT     L      MID-TMI2 230 KV                   .000         .000      P
          MIDDLJCT     X      5 BANK-S 115 KV                   .000         .000      P
          MIDDLJCT     OP     100482   230 KV    CB             .000         .000      P
          HUMMETAP     L      HUM-MID2 230 KV                   .000         .000      P
          MIDDLJCT     OP     B22      230 KV    CB             .000         .000      P
 9750    L115.CarlislePike-Gardners.1049                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARL PN      OP     KRGG MOA 115 KV    DIS            .000         .000      P
          CARL PN      OP     GEN_CB   115 KV    CB             .000         .000      P
          GARDNERS     L      CAR-GAR  115 KV                   .000         .000      P
          GARDNERS     OP     97682    115 KV    CB             .000         .000      P
 9760    L115.CarlislePike-Roxbury.1049                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARL PN      L      CAR-ROX  115 KV                   .000         .000      P
          ROXBURY      OP     KRG CL P 115 KV    CB             .000         .000      P
          CARL PN      OP     KRGR MOA 115 KV    DIS            .000         .000      P
 9770    L115.ShadeGap-ThreeSprings-Saxton                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHADEGAP     L      SHA-THR  115 KV                   .000         .000      P
          SAXTON       OP     K-SHD GP 115 KV    CB             .000         .000      P
          SAXTON       L      SAX-THR  115 KV                   .000         .000      P
          SHADEGAP     OP     K-SAXTON 115 KV    CB             .000         .000      P
 9780    L115.Claysburg-Curryville-Saxton.1099             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CLAYSBUR     L      CLA-CUR  115 KV                   .000         .000      P
          SAXTON       OP     CURRYVAU 115 KV    CB             .000         .000      P
          CURRYVIL     L      CUR-SAX  115 KV                   .000         .000      P
          CLAYSBUR     OP     B48      115 KV    CB             .000         .000      P
          SAXTON       OP     B24      115 KV    CB             .000         .000      P
          CURRYVIL     LD     #1 TX    115 KV                   .000         .000      P
          CLAYSBUR     OP     B49      115 KV    CB             .000         .000      P
 9790    L115.Claysburg-Summit.1060                        Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNNYN YNNYNNNNNNNNNNNNNNNNNNNYN
          CLAYSBUR     L      CLA-SUM  115 KV                   .000         .000      P
          CLAYSBUR     OP     B47      115 KV    CB             .000         .000      P
          SUMM PN      OP     CLAYSBSF 115 KV    CB             .000         .000      P
          CLAYSBUR     OP     B46      115 KV    CB             .000         .000      P
 9800    L115.SnakeSpring-Saxton                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SNAKESPR     OP     BSSEC115 115 KV    CB             .000         .000      P
          SAXTON       L      SAX-SNA  115 KV                   .000         .000      P
          SAXTON       OP     SYS SNSP 115 KV    CB             .000         .000      P
 9810    L115.BedfordNorth-SnakeSpring.1064                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BEDFORD      L      BED-SNA  115 KV                   .000         .000      P
          SNAKESPR     OP     BDFN115M 115 KV    DIS            .000         .000      P
          BEDFORD      OP     B26      115 KV    CB             .000         .000      P
 9820    L115.Allegheny-Somerset.1007                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ALLEGHEN     L      ALL-PRI  115 KV                   .000         .000      P
          SOME PN      L      PRI-SOM  115 KV                   .000         .000      P
          SOME PN      OP     PRIDE    115 KV    CB             .000         .000      P
          ALLEGHEN     OP     PRIDE    115 KV    DIS            .000         .000      P
 9830    L115.Lewistown-Reeds-ShadeGap                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          REEDSGAP     L      REE-REE  115 KV                   .000         .000      P
          BLAIN        LD     #1 TX    115 KV                   .000         .000      P
          REEDSSS      L      REE-SHA  115 KV                   .000         .000      P
          BLAIN        L      BLA-REE  115 KV                   .000         .000      P
          LEWISTOW     OP     SHDGPAUX 115 KV    CB             .000         .000      P
          SHADEGAP     OP     1-2 LWST 115 KV    CB             .000         .000      P
          LEWISTOW     OP     SHADE GP 115 KV    CB             .000         .000      P
          REEDSGAP     LD     1 TX     115 KV                   .000         .000      P
          LEWISTOW     L      LEW-REE  115 KV                   .000         .000      P
 9840    230/115/46.Lewistown.T1                           Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNNYN YNNYNNNNNNNNNNNNNNNNNNNYN
          LEWISTOW     X      NO1 -P   230 KV                   .000         .000      P
          LEWISTOW     L      JUN-LEW  230 KV                   .000         .000      P
          LEWISTOW     LD     NO1 TX   46 KV                    .000         .000      P
          LEWISTOW     OP     B29      230 KV    CB             .000         .000      P
          LEWISTOW     OP     B65      230 KV    CB             .000         .000      P
          LEWISTOW     OP     JUNIATSF 230 KV    CB             .000         .000      P
          LEWISTOW     L      LEW-YEA1 230 KV                   .000         .000      P
          LEWISTOW     X      NO1 -T   46 KV                    .000         .000      P
          LEWISTOW     OP     NO1TXAUX 115 KV    CB             .000         .000      P
          LEWISTOW     CP     #1 CAP   230 KV                   .000         .000      P
          LEWISTOW     OP     NO1TX115 115 KV    CB             .000         .000      P
          LEWISTOW     X      NO1 -S   115 KV                   .000         .000      P
          LEWISTOW     OP     BSSEC230 230 KV    CB             .000         .000      P
          LEWISTOW     OP     NO1TX46  46 KV     CB             .000         .000      P
          LEWISTOW     CP     #2 CAP   230 KV                   .000         .000      P
 9850    230/115/46.Lewistown.T2&T3                        Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNNYN YNNYNNNNNNNNNNNNNNNNNNNYN
          LEWISTOW     X      NO2 -T   46 KV                    .000         .000      P
          LEWISTOW     OP     B92      115 KV    CB             .000         .000      P
          LEWISTOW     LD     NO2 TX   46 KV                    .000         .000      P
          LEWISTOW     OP     NO2TX46  46 KV     CB             .000         .000      P
          LEWISTOW     X      NO2 -P   230 KV                   .000         .000      P
          LEWISTOW     OP     B34      230 KV    CB             .000         .000      P
          LEWISTOW     X      NO2 -S   115 KV                   .000         .000      P
          LEWISTOW     OP     BSSEC230 230 KV    CB             .000         .000      P
          LEWISTOW     OP     SHNGLTWN 230 KV    CB             .000         .000      P
          LEWISTOW     L      LEW-YEA2 230 KV                   .000         .000      P
          LEWISTOW     L      LEW-RAY  230 KV                   .000         .000      P
          LEWISTOW     X      NO3      230 KV                   .000         .000      P
          LEWISTOW     OP     NO2TXAUX 115 KV    CB             .000         .000      P
          LEWISTOW     OP     B5       230 KV    CB             .000         .000      P
          LEWISTOW     OP     NO2TX115 115 KV    CB             .000         .000      P
          LEWISTOW     L      LEW-SHI  230 KV                   .000         .000      P
 9860    L115.Mansfield-NilesValley.1095                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MANS PN      L      MAN-NIL  115 KV                   .000         .000      P
          NILESVAL     OP     MANSFIEL 115 KV    CB             .000         .000      P
          MANS PN      OP     NILESVLY 115 KV    CB             .000         .000      P
 9870    L115.NilesValley-Sabinsville-Gold-TennGas-Potter  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SABINSVI     OP     1_2TXMOA 115 KV    DIS            .000         .000       
          POTTER       OP     1CAP     115 KV    CB             .000         .000       
          NILESVAL     L      NIL-SAB  115 KV                   .000         .000       
          HECTOR       L      HEC-SAB  115 KV                   .000         .000       
          GOLD         OP     DUMGAS   115 KV    DIS            .000         .000       
          SABINSVI     LD     WELLBR   34 KV                    .000         .000       
          POTTER       LD     115LD2   115 KV                   .000         .000       
          TENNGAS      L      POT-TEN  115 KV                   .000         .000       
          POTTER       CP     CAP1     115 KV                   .000         .000       
          GOLD         L      GOL-TEN  115 KV                   .000         .000       
          NILESVAL     OP     POTTER11 115 KV    CB             .000         .000       
          POTTER       OP     BT CB    115 KV    DIS            .000         .000       
          POTTER       OP     2CAP     115 KV    CB             .000         .000       
          GOLD         OP     DUM15640 115 KV    DIS            .000         .000       
          POTTER       OP     NVL      115 KV    DIS            .000         .000       
          POTTER       CP     CAP2     115 KV                   .000         .000       
          SABINSVI     X      TR 1     115 KV                   .000         .000       
          GOLD         LD     NO.1 T   115 KV                   .000         .000       
          SABINSVI     LD     OSCEOL   34 KV                    .000         .000       
          GOLD         L      GOL-HEC  115 KV                   .000         .000       
          TENNGAS      LD     TENNGAS  115 KV                   .000         .000       
 9890    L115.PierceBrook-TwoMile-Potter + Relay.ESayre    Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          POTTER       OP     BT CB    115 KV    DIS            .000         .000       
          TWOMILE      LD     1BANK    115 KV                   .000         .000       
          ESAYRE       L      ESA-NWA  115 KV                   .000         .000       
          ESAYRE       OP     N WVRLY  115 KV    CB             .000         .000       
          PIERCEBR     OP     B14      115 KV    CB             .000         .000       
          PIERCEBR     OP     B13      115 KV    CB             .000         .000       
          PIERCEBR     L      PIE-TWO  115 KV                   .000         .000       
          TWOMILE      L      POT-TWO  115 KV                   .000         .000       
 9900    L115.LewisRun-FarmersValley                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FARMERSV     L      FAR-LEW  115 KV                   .000         .000       
          FARMERSV     OP     LEWISRUN 115 KV    CB             .000         .000       
          LEWISRN      OP     B7       115 KV    CB             .000         .000       
 9910    L115.Forest-Ridgway                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FOREST       OP     1TX115   115 KV    CB             .000         .000      P
          RIDG PN      OP     FORESTSF 115 KV    CB             .000         .000      P
          FOREST       L      FOR-RID  115 KV                   .000         .000      P
 9920    Ridgway-Whetstone 115 kV line                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WHETSTON     OP     DUBOIS11 115 KV    CB             .000         .000       
          RIDG PN      OP     WHETSTSF 115 KV    CB             .000         .000       
          RIDG PN      L      RID-WHE  115 KV                   .000         .000       
          WHETSTON     LD     BRCKW    115 KV                   .000         .000       
 9930    L115.Dubois-HarveyRun-Whetstone.982               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WHETSTON     OP     DUBOIS11 115 KV    CB             .000         .000       
          HARVEYRN     LD     1 TX     115 KV                   .000         .000       
          DUBOIS       L      DUB-HAR  115 KV                   .000         .000       
          HARVEYRN     L      HAR-WHE  115 KV                   .000         .000       
          DUBOIS       OP     WHETSTN  115 KV    CB             .000         .000       
 9940    L115.Dubois-RocktonMtn-Shawville.1076             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHAWVILL     OP     DUBOIS11 115 KV    CB             .000         .000      P
          DUBOIS       LD     3-TX     115 KV                   .000         .000      P
          DUBOIS       L      DUB-ROC  115 KV                   .000         .000      P
          ROCKTONM     L      ROC-SHA  115 KV                   .000         .000      P
          DUBOIS       OP     BSSCT115 115 KV    CB             .000         .000      P
          DUBOIS       OP     SHWVLMOA 115 KV    DIS            .000         .000      P
          ROCKTONM     LD     NO.1 T   115 KV                   .000         .000      P
 9950    Shawville.U1                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHAWVILL     OP     1BTX115  115 KV    CB             .000         .000       
          SHAWVILL     X      BNK 1B   115 KV                   .000         .000       
          SHAWVILL     U      UNIT 1   18 KV                    .000         .000       
          SHAWVILL     X      BNK 1A-P 230 KV                   .000         .000       
          SHAWVILL     OP     1ATX115  115 KV    CB             .000         .000       
          SHAWVILL     OP     1ATX230  230 KV    CB             .000         .000       
          SHAWVILL     X      BNK 1A-S 115 KV                   .000         .000       
 9960    Shawville.U2                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHAWVILL     U      UNIT 2   18 KV                    .000         .000       
          SHAWVILL     X      BNK 2A-P 230 KV                   .000         .000       
          SHAWVILL     OP     2ATX230  230 KV    CB             .000         .000       
          SHAWVILL     OP     2ATX115  115 KV    CB             .000         .000       
          SHAWVILL     OP     2BTX115  115 KV    CB             .000         .000       
          SHAWVILL     X      BNK 2A-S 115 KV                   .000         .000       
          SHAWVILL     X      BNK 2B   115 KV                   .000         .000       
 9970    L115.Garman-Westover-Mader-BioEnergy-Shawville.991Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHAWVILL     OP     GARMAN11 115 KV    CB             .000         .000       
          BIOENRGY     L      BIO-MAD  115 KV                   .000         .000       
          MADERA       LD     2 TX     115 KV                   .000         .000       
          GARMAN       L      GAR-WES  115 KV                   .000         .000       
          BIOENRGY     L      BIO-SHA  115 KV                   .000         .000       
          MADERA       LD     1 TX     115 KV                   .000         .000       
          MADERA       L      MAD-WES  115 KV                   .000         .000       
          WESTOVER     LD     1-TX     115 KV                   .000         .000       
          GARMAN       OP     SHAWVLLE 115 KV    CB             .000         .000       
 9980    L115.Glory-Garman.992                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GARMAN       LD     1 TX     115 KV                   .000         .000       
          GLORY        OP     GARMANSF 115 KV    CB             .000         .000       
          GARMAN       OP     BSSEC115 115 KV    CB             .000         .000       
          GARMAN       L      GAR-GLO  115 KV                   .000         .000       
 9990    L115.Shawville-Philipsburg.1079                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHAWVILL     OP     PHILBURG 115 KV    CB             .000         .000       
          PHILIPSB     LD     ONE      115 KV                   .000         .000       
          PHILIPSB     OP     BSSEC115 115 KV    CB             .000         .000       
          PHILIPSB     L      PHI-SHA  115 KV                   .000         .000       
10000    L115.EagleValley-TyroneN-Westfall.1037            Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNNYN YNNYNNNNNNNNNNNNNNNNNNNYN
          TYRONEN      OP     NO2 TX   46 KV     CB             .000         .000       
          TYRONEN      OP     NO1 TX   46 KV     CB             .000         .000       
          TYRONEN      X      BK_1     115 KV                   .000         .000       
          TYRONEN      X      BK_2     115 KV                   .000         .000       
          WESTFALL     OP     B11      115 KV    CB             .000         .000       
          EAGLEVAL     OP     1137-B1  115 KV    CB             .000         .000       
          EAGLEVAL     L      EAG-TYR  115 KV                   .000         .000       
          EAGLEVAL     OP     1137-B3  115 KV    CB             .000         .000       
          WESTFALL     OP     B15      115 KV    CB             .000         .000       
          TYRONEN      L      TYR-WES  115 KV                   .000         .000       
10010    L115.Summit-Thirty First St.                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          THIRTYST     L      THI-SUM  115 KV                   .000         .000       
          THIRTYST     OP     B2       115 KV    CB             .000         .000       
          THIRTYST     OP     B1       115 KV    CB             .000         .000       
          SUMM PN      OP     B6       115 KV    CB             .000         .000       
10020    L115.CorryEast-Warren                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CORRYE       OP     BSSCT115 115 KV    CB             .000         .000       
          CORRYE       OP     A5       115 KV    CB             .000         .000       
          CORRYE       X      BK3      115 KV                   .000         .000       
          CORRYE       L      COR-WAR  115 KV                   .000         .000       
          CORRYE       OP     B2       34.5 KV   CB             .000         .000       
          WARREN       OP     B29      115 KV    CB             .000         .000       
10050    L230.Bushkill-Shawnee + Shawnee.T4                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          BUSHKILL     OP     SHAWNCB  230 KV    CB             .000         .000       
          SHAWNEE      L      BUS-SHA  230 KV                   .000         .000       
          SHAWNEE      X      4 BANK   230 KV                   .000         .000       
          SHAWNEE      OP     B3       230 KV    CB             .000         .000       
          SHAWNEE      OP     4B32     34 KV     CB             .000         .000       
10060    L230.SouthManheim-BrunnerIsland + SouthManheim.T3 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SMANHEIM     X      3        230 KV                   .000         .000       
          BRUNNERI     OP     SMAN E   230 KV    CB             .000         .000       
          SMANHEIM     OP     TRAN_3   69 KV     CB             .000         .000       
          BRUNNERI     L      BRU-SMA  230 KV                   .000         .000       
          BRUNNERI     OP     SMAN W   230 KV    CB             .000         .000       
          SMANHEIM     OP     LINE_MOD 230 KV    CB             .000         .000       
10080    HQ-NPCC HVDC (W/O SANDY POND)                     Y Y Y L Y Y N N     NNNNYNNNNNNNNNNNNNYNNNNNN NNNNYNNNNNNNNNNNNNYNNNNNN
          HQNEWBRU     U      HQHVDC   345 KV                   .000         .000       
          COMERFOR     OP     345UNIT  345 KV    CB             .000         .000       
          CHATEAUG     OP     CB 02    765 KV    CB             .000         .000       
          COMERFOR     U      HQHVDC   345 KV                   .000         .000       
          CHATEAUG     OP     CB 03    765 KV    CB             .000         .000       
          CHATEAUG     U      DC-B     765 KV                   .000         .000       
          HQNEWBRU     OP     345 UNIT 345 KV    CB             .000         .000       
          HIGHGATE     OP     115 UNIT 115 KV    CB             .000         .000       
          CHATEAUG     U      DC-A     765 KV                   .000         .000       
          HIGHGATE     U      HQHVDC   115 KV                   .000         .000       
10090    L345.HomerCity-Watercure [NYISO] + Relay.ESayre   Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          HOMERCIT     OP     308      345 KV    CB             .000         .000       
          ESAYRE       OP     N WVRLY  115 KV    CB             .000         .000       
          WATERCUR     OP     B1-3042  345 KV    CB             .000         .000       
          ESAYRE       L      ESA-NWA  115 KV                   .000         .000       
          HOMERCIT     OP     307      345 KV    CB             .000         .000       
          WATERCUR     OP     30-3142  345 KV    CB             .000         .000       
10120    L230.Elko-SquabHollow                             Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNYYN YNNYNNNNNNNNNNNNNNNNNNYYN
          SQUABHOL     OP     B4       230 KV    CB             .000         .000       
          SQUABHOL     OP     B5       230 KV    CB             .000         .000       
          ELKO         OP     FOREST   230 KV    CB             .000         .000       
          ELKO         L      ELK-SQU1 230 KV                   .000         .000       
10130    L230.ErieEast-FourMile + Relay.Warren             Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          ERIEE        OP     ERIE SSF 230 KV    CB             .000         .000       
          ERIEE        L      4MIL-ERE 230 KV                   .000         .000       
          4MILEJCT     OP     B22      230 KV    CB             .000         .000       
          4MILEJCT     OP     B8       230 KV    CB             .000         .000       
          WARREN       OP     B32      115 KV    CB             .000         .000       
          FALCONER     L      FAL-WAR  115 KV                   .000         .000       
10140    L230.ErieSouth-FourMile + Relay.Warren            Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          FALCONER     L      FAL-WAR  115 KV                   .000         .000       
          ERIES        L      4MIL-ERI 230 KV                   .000         .000       
          4MILEJCT     OP     B2       230 KV    CB             .000         .000       
          WARREN       OP     B32      115 KV    CB             .000         .000       
          4MILEJCT     OP     B8       230 KV    CB             .000         .000       
          ERIES        OP     B38      230 KV    CB             .000         .000       
10150    L230.ErieEast-SouthRipley [NYISO] + Relay.Warren  Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SRIPLEY      OP     100      230 KV    CB             .000         .000       
          ERIEE        OP     S RIPLSF 230 KV    CB             .000         .000       
          FALCONER     L      FAL-WAR  115 KV                   .000         .000       
          WARREN       OP     B32      115 KV    CB             .000         .000       
          ERIEE        L      ERI-SRI  230 KV                   .000         .000       
10160    L230.ErieEast-SouthRipley [NYISO]                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SRIPLEY      L      ERI-SRI  230 KV                   .000         .000       
          SRIPLEY      OP     100      230 KV    CB             .000         .000       
          ERIEE        OP     S RIPLSF 230 KV    CB             .000         .000       
10170    L230.ErieEast-SthRipley [NYISO] + Seneca.1.Pump   Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          ERIEE        OP     S RIPLSF 230 KV    CB             .000         .000      P
          SENECA       U      1GEN     13 KV                    .000         .000      P
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          SRIPLEY      OP     100      230 KV    CB             .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
          SRIPLEY      L      ERI-SRI  230 KV                   .000         .000      P
10180    L230.ErieEast-SthRipley [NYISO] + Seneca.1&2.Pump Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SRIPLEY      L      ERI-SRI  230 KV                   .000         .000       
          SENECA       U      1GEN     13 KV                    .000         .000       
          SRIPLEY      OP     100      230 KV    CB             .000         .000       
          SENECA       U      2GEN     13 KV                    .000         .000       
          ERIEE        OP     S RIPLSF 230 KV    CB             .000         .000       
          SENECA       X      NO2 230  230 KV                   .000         .000       
          SENECA       X      NO1 230  230 KV                   .000         .000       
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000       
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000       
10190    L230.ErieEast-SthRipley [NYISO] + Seneca.2.Pump   Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          ERIEE        OP     S RIPLSF 230 KV    CB             .000         .000       
          SENECA       X      NO2 230  230 KV                   .000         .000       
          SENECA       U      2GEN     13 KV                    .000         .000       
          SRIPLEY      OP     100      230 KV    CB             .000         .000       
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000       
          SRIPLEY      L      ERI-SRI  230 KV                   .000         .000       
10200    L230.ErieE-SRipley + Relay.Warren + Seneca.1.Pump Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SRIPLEY      OP     100      230 KV    CB             .000         .000       
          SENECA       X      NO1 230  230 KV                   .000         .000       
          FALCONER     L      FAL-WAR  115 KV                   .000         .000       
          WARREN       OP     B32      115 KV    CB             .000         .000       
          ERIEE        OP     S RIPLSF 230 KV    CB             .000         .000       
          SENECA       U      1GEN     13 KV                    .000         .000       
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000       
          ERIEE        L      ERI-SRI  230 KV                   .000         .000       
10210    L230.ErieE-SRipley + Relay.Warren + Seneca.2.Pump Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          FALCONER     L      FAL-WAR  115 KV                   .000         .000      P
          SRIPLEY      OP     100      230 KV    CB             .000         .000      P
          ERIEE        OP     S RIPLSF 230 KV    CB             .000         .000      P
          ERIEE        L      ERI-SRI  230 KV                   .000         .000      P
          SENECA       X      NO2 230  230 KV                   .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
          WARREN       OP     B32      115 KV    CB             .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
10220    L230.ErieE-SRipley+Relay.Warren+Seneca.1&2.Pump   Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000       
          SENECA       X      NO1 230  230 KV                   .000         .000       
          SENECA       X      NO2 230  230 KV                   .000         .000       
          SRIPLEY      OP     100      230 KV    CB             .000         .000       
          SENECA       U      2GEN     13 KV                    .000         .000       
          FALCONER     L      FAL-WAR  115 KV                   .000         .000       
          SENECA       U      1GEN     13 KV                    .000         .000       
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000       
          ERIEE        OP     S RIPLSF 230 KV    CB             .000         .000       
          WARREN       OP     B32      115 KV    CB             .000         .000       
          ERIEE        L      ERI-SRI  230 KV                   .000         .000       
10260    230/115.EastTowanda.T4                            Y Y Y S Y Y N N     YNNYNNNNNNYNNNNNNNNNNNYYN YNNYNNNNNNYNNNNNNNNNNNYYN
          ETOWANDA     OP     NO4TX115 115 KV    CB             .000         .000      P
          ETOWANDA     X      4 TX     230 KV                   .000         .000      P
          ETOWANDA     OP     B29 CB   230 KV    CB             .000         .000      P
10270    230/115.ETowanda.T4 + Seneca.1.Pump               Y Y Y S Y Y N N     NNNYNNNNNNYNNNNNNNNNNNNNN NNNYNNNNNNYNNNNNNNNNNNNNN
          SENECA       U      1GEN     13 KV                    .000         .000      P
          ETOWANDA     OP     NO4TX115 115 KV    CB             .000         .000      P
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          ETOWANDA     X      4 TX     230 KV                   .000         .000      P
          ETOWANDA     OP     B29 CB   230 KV    CB             .000         .000      P
10280    230/115.ETowanda.T4 + Seneca.2.Pump               Y Y Y S Y Y N N     NNNYNNNNNNYNNNNNNNNNNNNNN NNNYNNNNNNYNNNNNNNNNNNNNN
          ETOWANDA     X      4 TX     230 KV                   .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
          ETOWANDA     OP     NO4TX115 115 KV    CB             .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
          ETOWANDA     OP     B29 CB   230 KV    CB             .000         .000      P
10290    230/115.ETowanda.T4 + Seneca.1&2.Pump             Y Y Y S Y Y N N     NNNYNNNNNNYNNNNNNNNNNNNNN NNNYNNNNNNYNNNNNNNNNNNNNN
          ETOWANDA     OP     NO4TX115 115 KV    CB             .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
          ETOWANDA     X      4 TX     230 KV                   .000         .000      P
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          SENECA       U      1GEN     13 KV                    .000         .000      P
          ETOWANDA     OP     B29 CB   230 KV    CB             .000         .000      P
10300    230/115.EastTowanda.T3 + Relay.ESayre             Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          ESAYRE       OP     N WVRLY  115 KV    CB             .000         .000       
          ESAYRE       L      ESA-NWA  115 KV                   .000         .000       
          ETOWANDA     OP     B39      230 KV    CB             .000         .000       
          ETOWANDA     OP     B7       115 KV    CB             .000         .000       
          ETOWANDA     OP     B2       230 KV    CB             .000         .000       
          ETOWANDA     X      3 TX     230 KV                   .000         .000       
10310    230/115.EastTowanda.T3                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          ETOWANDA     OP     B2       230 KV    CB             .000         .000       
          ETOWANDA     OP     B39      230 KV    CB             .000         .000       
          ETOWANDA     X      3 TX     230 KV                   .000         .000       
          ETOWANDA     OP     B7       115 KV    CB             .000         .000       
10320    L230.ErieSouth-Warren.2008 + Relay.Warren         Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNYNN NNNYNNNNNNNNNNNNNNNNNNYNN
          WARREN       L      FAL-WAR  115 KV                   .000         .000       
          WARREN       OP     B32      115 KV    CB             .000         .000       
          ERIES        OP     WARREN23 230 KV    CB             .000         .000       
          WARREN       OP     B50      230 KV    CB             .000         .000       
          ERIES        L      ERI-WAR  230 KV                   .000         .000       
          WARREN       OP     B53      230 KV    CB             .000         .000       
10330    L69.UpperSaddleRiver-SouthMahwah                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SMAWA        OP     652-52-2 69 KV     CB             .000         .000      P
          UPPERSAD     OP     652-49-2 69 KV     DIS            .000         .000      P
          SMAWA        L      SMA-UPP  69 KV                    .000         .000      P
10340    L500.HopeCreek-Salem.5037                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNYYN YNNNNNNNNNNNNNNYNNNNNNYYN
          HOPECREE     OP     SECT2-6  500 KV    CB             .000         .000      P
          HOPECREE     OP     NO4STAPW 500 KV    DIS            .000         .000      P
          HOPECREE     OP     NO2STAPW 500 KV    DIS            .000         .000      P
          HOPECREE     LD     SLP_2 NC 500 KV                   .000         .000      P
          SALEM        L      HOP-SAL  500 KV                   .000         .000      P
          HOPECREE     OP     5037     500 KV    DIS            .000         .000      P
          SALEM        OP     DUM18402 500 KV    DIS            .000         .000      P
          HOPECREE     LD     SLP_4 NC 500 KV                   .000         .000      P
          SALEM        OP     SECT2-10 500 KV    CB             .000         .000      P
          SALEM        OP     SECT9-10 500 KV    CB             .000         .000      P
          HOPECREE     OP     2-4      500 KV    CB             .000         .000      P
10350    L500.HopeCreek-NewFreedom.5023                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          NEWFREED     OP     SECT3-4  500 KV    CB             .000         .000      P
          HOPECREE     OP     SECT1-5  500 KV    CB             .000         .000      P
          NEWFREED     L      HOP-NEW  500 KV                   .000         .000      P
          NEWFREED     OP     SECT2-4  500 KV    CB             .000         .000      P
          HOPECREE     OP     SECT5-6  500 KV    CB             .000         .000      P
10360    HopeCreek.U1 (for TLC)                            Y Y Y S Y Y N N     NNNNNNNNNNNNNNNYNNNNNNYNN NNNNNNNNNNNNNNNYNNNNNNYNN
          HOPECREE     OP     SECT2-6  500 KV    CB             .000         .000      P
          HOPECREE     U      UNIT 1   25 KV                    .000         .000      P
          HOPECREE     OP     SECT5-6  500 KV    CB             .000         .000      P
          HOPECREE     X      NO 1GSU  500 KV                   .000         .000      P
10370    L500.HopeCreek-RedLion.5015                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNYYNNNNNNYYN YNNNNNNNNNNNNNYYNNNNNNYYN
          REDLION      OP     505      500 KV    CB             .000         .000      P
          REDLION      L      HOP-RED  500 KV                   .000         .000      P
          HOPECREE     OP     SECT1-3  500 KV    CB             .000         .000      P
          REDLION      OP     503      500 KV    CB             .000         .000      P
          HOPECREE     OP     5015 BKR 500 KV    DIS            .000         .000      P
          REDLION      OP     5015L1   500 KV    DIS            .000         .000      P
          HOPECREE     OP     SECT3-4  500 KV    CB             .000         .000      P
10380    L230.Glade-Warren.2088 + Relay.ESayre             Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          ESAYRE       L      ESA-NWA  115 KV                   .000         .000       
          GLADE        OP     B1       230 KV    CB             .000         .000       
          GLADE        L      GLA-WAR  230 KV                   .000         .000       
          WARREN       OP     B43      230 KV    CB             .000         .000       
          WARREN       OP     B46      230 KV    CB             .000         .000       
          GLADE        OP     B2       230 KV    CB             .000         .000       
          ESAYRE       OP     N WVRLY  115 KV    CB             .000         .000       
10410    L230.SteelCity-Quarry.1                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          STEELCTY     OP     QUAR1_W  230 KV    CB             .000         .000       
          STEELCTY     OP     QUAR1_E  230 KV    CB             .000         .000       
          QUARRY       OP     STCI1_E  230 KV    CB             .000         .000       
          QUARRY       L      QUA-STE  230 KV                   .000         .000       
          QUARRY       OP     STCI1_W  230 KV    CB             .000         .000       
10610    Salem.U1&U2                                       Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          SALEM        X      NO 1GSU  500 KV                   .000         .000      P
          SALEM        CL     DUMNUKE8 500 KV    DIS            .000         .000      P
          SALEM        CL     DUMNUK10 500 KV    DIS            .000         .000      P
          SALEM        OP     SECT1-9  500 KV    CB             .000         .000      P
          SALEM        OP     SECT1-5  500 KV    CB             .000         .000      P
          SALEM        CL     DUMNUKE5 500 KV    DIS            .000         .000      P
          SALEM        X      NO 2GSU  500 KV                   .000         .000      P
          SALEM        CL     DUMNUKE6 500 KV    DIS            .000         .000      P
          SALEM        OP     SECT5-6  500 KV    CB             .000         .000      P
          SALEM        CL     DUMNUKE1 500 KV    DIS            .000         .000      P
          SALEM        CL     DUMNUKE2 500 KV    DIS            .000         .000      P
          SALEM        CL     DUMNUKE9 500 KV    DIS            .000         .000      P
          SALEM        U      SALEM2   25 KV                    .000         .000      P
          SALEM        U      SALEM1   25 KV                    .000         .000      P
          SALEM        OP     SECT9-10 500 KV    CB             .000         .000      P
10630    L500.Deans-EastWindsor.5022                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNYNNNNNNYYN YNNNNNNNNNNNNNNYNNNNNNYYN
          EWINDSOR     OP     B16      500 KV    CB             .000         .000       
          DEANS        OP     SECT 2-6 500 KV    CB             .000         .000       
          DEANS        OP     5022 DIS 500 KV    DIS            .000         .000       
          EWINDSOR     OP     DUM DEAN 500 KV    DIS            .000         .000       
          EWINDSOR     OP     B13      500 KV    CB             .000         .000       
          DEANS        OP     SECT 5-6 500 KV    CB             .000         .000       
          EWINDSOR     L      DEA-EWI  500 KV                   .000         .000       
10660    Linden-Bayway (W-1323) 138 kV line                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LINDEN       OP     W-1323-3 138 KV    CB             .000         .000      P
          LINDEN       OP     WTRNSFBU 138 KV    DIS            .000         .000      P
10670    PVSC-North Avenue (E-1331) 138 kV line            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NORTHAV      L      NOR-PVS  138 KV                   .000         .000      P
          PVSC         OP     E-1331   138 KV    DIS            .000         .000      P
          NORTHAV      OP     TRAN T-1 138 KV    DIS            .000         .000      P
          NORTHAV      CL     LOADTRAN 138 KV    DIS            .000         .000      P
          NORTHAV      OP     SECT 1-2 138 KV    CB             .000         .000      P
10680    North Avenue-Linden (T-1346) 138 kV line          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NORTHAV      OP     SECT 1-2 138 KV    CB             .000         .000      P
          LINDEN       OP     TTRNSFBU 138 KV    DIS            .000         .000      P
          NORTHAV      OP     TRAN T-2 138 KV    DIS            .000         .000      P
          LINDEN       OP     T-1346   138 KV    CB             .000         .000      P
          LINDEN       L      LIN-NOR  138 KV                   .000         .000      P
          NORTHAV      CL     LOADTRAN 138 KV    DIS            .000         .000      P
10760    L230.Burtonsville-MetzerottRoad-Takoma.23040/23018Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TAKOMA       OP     69K1B    69 KV     CB             .000         .000      P
          METZTAP      OP     1TS1B    69 KV     CB             .000         .000      P
          BURTONSV     L      BUR-MET0 230 KV                   .000         .000      P
          METZTAP      OP     1TS2B    69 KV     CB             .000         .000      P
          TAKOMA       X      027-8T   230 KV                   .000         .000      P
          TAKOMA       OP     10TS3B   34 KV     CB             .000         .000      P
          TAKOMA       OP     10TS4B   34 KV     CB             .000         .000      P
          TAKOMA       X      027-10T  230 KV                   .000         .000      P
          BURTONSV     OP     23040B   230 KV    CB             .000         .000      P
          TAKOMA       OP     69K2B    69 KV     CB             .000         .000      P
          METZTAP      X      163-1T   230 KV                   .000         .000      P
          METZTAP      L      MET-TAK8 230 KV                   .000         .000      P
10770    L230.Burtonsville-MetzerottRoad-Takoma.23041/23019Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BURTONSV     OP     23041-B  230 KV    CB             .000         .000      P
          TAKOMA       OP     69K11B   69 KV     CB             .000         .000      P
          METZTAP      OP     4TS4B    69 KV     CB             .000         .000      P
          METZTAP      X      163-4T   230 KV                   .000         .000      P
          TAKOMA       OP     69K9B    69 KV     CB             .000         .000      P
          TAKOMA       X      027-12T  230 KV                   .000         .000      P
          TAKOMA       L      MET-TAK9 230 KV                   .000         .000      P
          TAKOMA       P      12PAC    69 KV                    .000         .000      P
          METZTAP      OP     4TS1B    69 KV     CB             .000         .000      P
          BURTONSV     L      BUR-MET8 230 KV                   .000         .000      P
10780    L230.Burtonsville-MetzerottRoad-Takoma.23046/23020Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BURTONSV     L      BUR-MET6 230 KV                   .000         .000      P
          TAKOMA       OP     5TS1B    34 KV     CB             .000         .000      P
          METZTAP      OP     3TS4B    69 KV     CB             .000         .000      P
          METZTAP      X      163-3T   230 KV                   .000         .000      P
          TAKOMA       P      7PAC     69 KV                    .000         .000      P
          METZTAP      OP     3TS3B    69 KV     CB             .000         .000      P
          TAKOMA       X      027-7T   230 KV                   .000         .000      P
          TAKOMA       OP     5TS3B    34 KV     CB             .000         .000      P
          TAKOMA       OP     69K12B   69 KV     CB             .000         .000      P
          TAKOMA       X      027-5T   230 KV                   .000         .000      P
          METZTAP      L      MET-TAK0 230 KV                   .000         .000      P
          BURTONSV     OP     23046B   230 KV    CB             .000         .000      P
          TAKOMA       OP     69K10B   69 KV     CB             .000         .000      P
10790    L230.Burtonsville-MetzerottRoad-Takoma.23047/23021Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          METZTAP      X      163-2T   230 KV                   .000         .000      P
          BURTONSV     OP     23047B   230 KV    CB             .000         .000      P
          METZTAP      OP     2TS2B    69 KV     CB             .000         .000      P
          BURTONSV     L      BUR-MET7 230 KV                   .000         .000      P
          TAKOMA       OP     6TS4B    34 KV     CB             .000         .000      P
          TAKOMA       OP     6TS2B    34 KV     CB             .000         .000      P
          TAKOMA       X      027-6T   230 KV                   .000         .000      P
          METZTAP      OP     2TS3B    69 KV     CB             .000         .000      P
          METZTAP      L      MET-TAK1 230 KV                   .000         .000      P
10800    L230.OakGrove-Ritchie.23059 + 230/69.Ritchie.T3   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OAKGROVE     L      OAK-RIT9 230 KV                   .000         .000      P
          RITCHIE      OP     3TS4B    69 KV     CB             .000         .000      P
          RITCHIE      OP     23003B   230 KV    CB             .000         .000      P
          RITCHIE      OP     23016B   230 KV    CB             .000         .000      P
          RITCHIE      X      123-3T   230 KV                   .000         .000      P
          RITCHIE      OP     3TS3B    69 KV     CB             .000         .000      P
          OAKGROVE     OP     4AB      230 KV    CB             .000         .000      P
          OAKGROVE     OP     4CB      230 KV    CB             .000         .000      P
10810    L230.OakGrove-Ritchie.23060 + 230/69.Ritchie.T2   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RITCHIE      OP     2TS2B    69 KV     CB             .000         .000      P
          RITCHIE      OP     2TS3B    69 KV     CB             .000         .000      P
          OAKGROVE     L      OAK-RIT0 230 KV                   .000         .000      P
          OAKGROVE     OP     2AB      230 KV    CB             .000         .000      P
          RITCHIE      OP     23051B   230 KV    CB             .000         .000      P
          RITCHIE      OP     23004B   230 KV    CB             .000         .000      P
          RITCHIE      X      123-2T   230 KV                   .000         .000      P
          OAKGROVE     OP     2BB      230 KV    CB             .000         .000      P
10830    L230.BuzzardPoint-Ritchie.23016                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BUZZARD      L      BUZ-RIT  230 KV                   .000         .000       
          BUZZARD      X      STAB-7-  230 KV                   .000         .000       
          BUZZARD      OP     7TSBCB   138 KV    CB             .000         .000       
          RITCHIE      OP     23016B   230 KV    CB             .000         .000       
          BUZZARD      CP     B-016    230 KV                   .000         .000       
          BUZZARD      P      7T-PS    138 KV                   .000         .000       
10840    L230.Benning-Ritchie.23003                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RITCHIE      OP     23003B   230 KV    CB             .000         .000       
          BENNING      OP     2CB      230 KV    CB             .000         .000       
          BENNING      L      BEN-RIT3 230 KV                   .000         .000       
          BENNING      OP     2BB      230 KV    CB             .000         .000       
10850    L230.Bowie-Aquasco-ChalkPoint.23153/23063         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHALKPT      OP     4BB      230 KV    CB             .000         .000       
          BOWIE        OP     23054LB  230 KV    CB             .000         .000       
          CHALKPT      OP     4AB      230 KV    CB             .000         .000       
          AQUASCO      L      AQU-BOW  230 KV                   .000         .000       
          AQUASCO      L      AQU-CHA2 230 KV                   .000         .000       
10860    L230.Bowie-ChalkPoint.23065                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BOWIE        OP     23065B   230 KV    CB             .000         .000       
          CHALKPT      OP     1AB      230 KV    CB             .000         .000       
          BOWIE        L      BOW-CHA5 230 KV                   .000         .000       
          CHALKPT      OP     1BB      230 KV    CB             .000         .000       
10870    L230.WaughChapel-JerichoPark-Bowie.2341           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JERICHOP     S      2341SD   230 KV                   .000         .000      P
          WAUGHCHA     OP     23411BUS 230 KV    CB             .000         .000      P
          WAUGHCHA     OP     23414BUS 230 KV    CB             .000         .000      P
          JERICHOP     L      JER-WAU1 230 KV                   .000         .000      P
          JERICHOP     L      BOW-JER1 230 KV                   .000         .000      P
          JERICHOP     OP     2341-51  230 KV    CB             .000         .000      P
          BOWIE        OP     2341B    230 KV    CB             .000         .000      P
10880    L230.OakGrove-Ritchie.23058 + 230/69.Ritchie.T1   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RITCHIE      OP     1TS2B    69 KV     CB             .000         .000      P
          OAKGROVE     OP     6BB      230 KV    CB             .000         .000      P
          RITCHIE      OP     23002B   230 KV    CB             .000         .000      P
          RITCHIE      OP     1TS1B    69 KV     CB             .000         .000      P
          RITCHIE      X      123-1T   230 KV                   .000         .000      P
          OAKGROVE     L      OAK-RIT8 230 KV                   .000         .000      P
          OAKGROVE     OP     6AB      230 KV    CB             .000         .000      P
10890    L230.Glade-Warren.2088 + Relay.Warren             Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          WARREN       OP     B32      115 KV    CB             .000         .000      P
          WARREN       L      GLA-WAR  230 KV                   .000         .000      P
          WARREN       OP     B46      230 KV    CB             .000         .000      P
          WARREN       OP     B43      230 KV    CB             .000         .000      P
          WARREN       L      FAL-WAR  115 KV                   .000         .000      P
          GLADE        OP     B2       230 KV    CB             .000         .000      P
          GLADE        OP     B1       230 KV    CB             .000         .000      P
10900    L345.ErieSouth-ErieWest.3001 + Relay.Warren       Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          WARREN       OP     B32      115 KV    CB             .000         .000      P
          ERIES        X      5 TX  3  345 KV                   .000         .000      P
          ERIEW        OP     B9       345 KV    CB             .000         .000      P
          ERIEW        OP     B8       345 KV    CB             .000         .000      P
          ERIES        OP     128 B2   345 KV    CB             .000         .000      P
          ERIES        X      NO8 TX   345 KV                   .000         .000      P
          WARREN       L      FAL-WAR  115 KV                   .000         .000      P
          ERIES        OP     128 B1   345 KV    CB             .000         .000      P
          ERIES        L      ERI-ERI  345 KV                   .000         .000      P
10910    230/115.ErieSouth.T6                              Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNNYN YNNYNNNNNNNNNNNNNNNNNNNYN
          ERIES        OP     NO5TX230 230 KV    CB             .000         .000       
          ERIES        LD     3 TX 3   230 KV                   .000         .000       
          ERIES        X      6 TX     230 KV                   .000         .000       
          ERIES        CP     WEST     230 KV                   .000         .000       
          ERIES        LD     7 TX     230 KV                   .000         .000       
          ERIES        X      5 TX  3  345 KV                   .000         .000       
          ERIES        OP     B27      230 KV    CB             .000         .000       
          ERIES        OP     CAPWESTC 230 KV    CB             .000         .000       
          ERIES        OP     NO6TX115 115 KV    CB             .000         .000       
10920    230/115.ErieSouth.T6 + Seneca.1.Pump              Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          ERIES        OP     B27      230 KV    CB             .000         .000       
          SENECA       U      1GEN     13 KV                    .000         .000       
          SENECA       X      NO1 230  230 KV                   .000         .000       
          ERIES        CP     WEST     230 KV                   .000         .000       
          ERIES        OP     NO6TX115 115 KV    CB             .000         .000       
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000       
          ERIES        LD     7 TX     230 KV                   .000         .000       
          ERIES        X      6 TX     230 KV                   .000         .000       
          ERIES        LD     3 TX 3   230 KV                   .000         .000       
          ERIES        OP     CAPWESTC 230 KV    CB             .000         .000       
          ERIES        X      5 TX  3  345 KV                   .000         .000       
          ERIES        OP     NO5TX230 230 KV    CB             .000         .000       
10930    230/115.ErieSouth.T6 + Seneca.1&2.Pump            Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000       
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000       
          SENECA       U      1GEN     13 KV                    .000         .000       
          ERIES        OP     NO6TX115 115 KV    CB             .000         .000       
          SENECA       X      NO1 230  230 KV                   .000         .000       
          ERIES        OP     B27      230 KV    CB             .000         .000       
          ERIES        LD     3 TX 3   230 KV                   .000         .000       
          SENECA       U      2GEN     13 KV                    .000         .000       
          ERIES        OP     CAPWESTC 230 KV    CB             .000         .000       
          ERIES        X      5 TX  3  345 KV                   .000         .000       
          ERIES        LD     7 TX     230 KV                   .000         .000       
          ERIES        OP     NO5TX230 230 KV    CB             .000         .000       
          SENECA       X      NO2 230  230 KV                   .000         .000       
          ERIES        CP     WEST     230 KV                   .000         .000       
          ERIES        X      6 TX     230 KV                   .000         .000       
10940    230/115.ErieSouth.T6 + Seneca.2.Pump              Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000       
          ERIES        X      5 TX  3  345 KV                   .000         .000       
          ERIES        OP     NO6TX115 115 KV    CB             .000         .000       
          SENECA       X      NO2 230  230 KV                   .000         .000       
          ERIES        X      6 TX     230 KV                   .000         .000       
          ERIES        LD     3 TX 3   230 KV                   .000         .000       
          ERIES        OP     B27      230 KV    CB             .000         .000       
          ERIES        CP     WEST     230 KV                   .000         .000       
          ERIES        OP     CAPWESTC 230 KV    CB             .000         .000       
          ERIES        OP     NO5TX230 230 KV    CB             .000         .000       
          SENECA       U      2GEN     13 KV                    .000         .000       
          ERIES        LD     7 TX     230 KV                   .000         .000       
10950    230/115.ErieSouth.T6 + Relay.Warren               Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          ERIES        X      6 TX     230 KV                   .000         .000      P
          WARREN       OP     B32      115 KV    CB             .000         .000      P
          ERIES        OP     NO5TX230 230 KV    CB             .000         .000      P
          ERIES        LD     7 TX     230 KV                   .000         .000      P
          ERIES        X      5 TX  3  345 KV                   .000         .000      P
          ERIES        LD     3 TX 3   230 KV                   .000         .000      P
          ERIES        OP     B27      230 KV    CB             .000         .000      P
          ERIES        OP     NO6TX115 115 KV    CB             .000         .000      P
          ERIES        CP     WEST     230 KV                   .000         .000      P
          ERIES        OP     CAPWESTC 230 KV    CB             .000         .000      P
          WARREN       L      FAL-WAR  115 KV                   .000         .000      P
10960    230/115.ErieSouth.T6+Relay.Warren+Seneca.1.Pump   Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       U      1GEN     13 KV                    .000         .000      P
          ERIES        X      6 TX     230 KV                   .000         .000      P
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          WARREN       L      FAL-WAR  115 KV                   .000         .000      P
          ERIES        LD     3 TX 3   230 KV                   .000         .000      P
          ERIES        OP     NO6TX115 115 KV    CB             .000         .000      P
          ERIES        OP     CAPWESTC 230 KV    CB             .000         .000      P
          ERIES        CP     WEST     230 KV                   .000         .000      P
          ERIES        OP     NO5TX230 230 KV    CB             .000         .000      P
          ERIES        X      5 TX  3  345 KV                   .000         .000      P
          WARREN       OP     B32      115 KV    CB             .000         .000      P
          ERIES        OP     B27      230 KV    CB             .000         .000      P
          ERIES        LD     7 TX     230 KV                   .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
10970    230/115.ErieSouth.T6+Relay.Warren+Seneca.1&2.Pump Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          WARREN       L      FAL-WAR  115 KV                   .000         .000      P
          ERIES        OP     CAPWESTC 230 KV    CB             .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
          ERIES        LD     7 TX     230 KV                   .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
          ERIES        OP     B27      230 KV    CB             .000         .000      P
          SENECA       X      NO2 230  230 KV                   .000         .000      P
          ERIES        X      5 TX  3  345 KV                   .000         .000      P
          ERIES        OP     NO5TX230 230 KV    CB             .000         .000      P
          ERIES        LD     3 TX 3   230 KV                   .000         .000      P
          ERIES        X      6 TX     230 KV                   .000         .000      P
          ERIES        OP     NO6TX115 115 KV    CB             .000         .000      P
          WARREN       OP     B32      115 KV    CB             .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
          SENECA       U      1GEN     13 KV                    .000         .000      P
          ERIES        CP     WEST     230 KV                   .000         .000      P
10980    230/115.ErieSouth.T6+Relay.Warren+Seneca.2.Pump   Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          ERIES        OP     CAPWESTC 230 KV    CB             .000         .000      P
          ERIES        LD     7 TX     230 KV                   .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
          WARREN       L      FAL-WAR  115 KV                   .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
          WARREN       OP     B32      115 KV    CB             .000         .000      P
          ERIES        LD     3 TX 3   230 KV                   .000         .000      P
          SENECA       X      NO2 230  230 KV                   .000         .000      P
          ERIES        OP     NO6TX115 115 KV    CB             .000         .000      P
          ERIES        OP     NO5TX230 230 KV    CB             .000         .000      P
          ERIES        CP     WEST     230 KV                   .000         .000      P
          ERIES        X      5 TX  3  345 KV                   .000         .000      P
          ERIES        X      6 TX     230 KV                   .000         .000      P
          ERIES        OP     B27      230 KV    CB             .000         .000      P
10990    L115.EastTowanda-NorthMeshoppen.1057              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NMESHOPP     OP     E TOWNSF 115 KV    CB             .000         .000      P
          ETOWANDA     OP     N MESHOP 115 KV    CB             .000         .000      P
          ETOWANDA     L      ETO-NME  115 KV                   .000         .000      P
11000    345/230.HomerCity.AT-N + Seneca.1.Pump            Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          HOMERCIT     OP     304      345 KV    CB             .000         .000      P
          HOMERCIT     OP     XFNLDTER 23 KV     CB             .000         .000      P
          HOMERCIT     X      N.AUTO-P 345 KV                   .000         .000      P
          HOMERCIT     X      N.AUTO-S 230 KV                   .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          HOMERCIT     X      N.AUTO-T 23 KV                    .000         .000      P
          SENECA       U      1GEN     13 KV                    .000         .000      P
          HOMERCIT     OP     301      345 KV    CB             .000         .000      P
          HOMERCIT     OP     307      345 KV    CB             .000         .000      P
          HOMERCIT     OP     210      230 KV    CB             .000         .000      P
11010    345/230.HomerCity.AT-N + Seneca.1&2.Pump          Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          HOMERCIT     OP     XFNLDTER 23 KV     CB             .000         .000      P
          HOMERCIT     X      N.AUTO-S 230 KV                   .000         .000      P
          HOMERCIT     OP     307      345 KV    CB             .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
          SENECA       X      NO2 230  230 KV                   .000         .000      P
          HOMERCIT     X      N.AUTO-P 345 KV                   .000         .000      P
          HOMERCIT     OP     301      345 KV    CB             .000         .000      P
          HOMERCIT     OP     210      230 KV    CB             .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
          SENECA       U      1GEN     13 KV                    .000         .000      P
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          HOMERCIT     X      N.AUTO-T 23 KV                    .000         .000      P
          HOMERCIT     OP     304      345 KV    CB             .000         .000      P
11020    345/230.HomerCity.AT-N + Seneca.2.Pump            Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          HOMERCIT     OP     301      345 KV    CB             .000         .000      P
          HOMERCIT     X      N.AUTO-P 345 KV                   .000         .000      P
          HOMERCIT     OP     307      345 KV    CB             .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
          HOMERCIT     OP     210      230 KV    CB             .000         .000      P
          SENECA       X      NO2 230  230 KV                   .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
          HOMERCIT     X      N.AUTO-S 230 KV                   .000         .000      P
          HOMERCIT     OP     XFNLDTER 23 KV     CB             .000         .000      P
          HOMERCIT     X      N.AUTO-T 23 KV                    .000         .000      P
          HOMERCIT     OP     304      345 KV    CB             .000         .000      P
11030    L345.ErieWest-Wayne.3004 + Seneca.1.Pump          Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          ERIEW        OP     B79      345 KV    CB             .000         .000       
          SENECA       X      NO1 230  230 KV                   .000         .000       
          SENECA       U      1GEN     13 KV                    .000         .000       
          WAYNE        OP     B45      345 KV    CB             .000         .000       
          ERIEW        OP     B82      345 KV    CB             .000         .000       
          WAYNE        OP     B30      345 KV    CB             .000         .000       
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000       
          WAYNE        L      ERI-WAY  345 KV                   .000         .000       
11040    L345.ErieWest-Wayne.3004 + Seneca.1&2.Pump        Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000       
          ERIEW        OP     B79      345 KV    CB             .000         .000       
          SENECA       U      1GEN     13 KV                    .000         .000       
          SENECA       X      NO2 230  230 KV                   .000         .000       
          SENECA       X      NO1 230  230 KV                   .000         .000       
          ERIEW        OP     B82      345 KV    CB             .000         .000       
          SENECA       U      2GEN     13 KV                    .000         .000       
          WAYNE        OP     B30      345 KV    CB             .000         .000       
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000       
          WAYNE        L      ERI-WAY  345 KV                   .000         .000       
          WAYNE        OP     B45      345 KV    CB             .000         .000       
11050    L345.ErieWest-Wayne.3004 + Seneca.2.Pump          Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          WAYNE        OP     B45      345 KV    CB             .000         .000       
          SENECA       U      2GEN     13 KV                    .000         .000       
          WAYNE        L      ERI-WAY  345 KV                   .000         .000       
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000       
          ERIEW        OP     B82      345 KV    CB             .000         .000       
          ERIEW        OP     B79      345 KV    CB             .000         .000       
          WAYNE        OP     B30      345 KV    CB             .000         .000       
          SENECA       X      NO2 230  230 KV                   .000         .000       
11060    138/69/12.Vanburen.T1                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          VANBUREN     X      1-S      69 KV                    .000         .000       
          VANBUREN     OP     B        69 KV     CB             .000         .000       
          VANBUREN     OP     XT1      138 KV    CB             .000         .000       
          VANBUREN     X      1-P      138 KV                   .000         .000       
          VANBUREN     LD     LOAD     69 KV                    .000         .000       
          VANBUREN     X      1-T      12 KV                    .000         .000       
          VANBUREN     LD     12KV     12 KV                    .000         .000       
          VANBUREN     L      LIB-VAN  69 KV                    .000         .000       
11070    L500.Meadow Brook-FrontRoyal.580                  Y Y Y S Y Y N N     YNNNNYYNNNNNNNNNNNNNNNYYN YNNNNYYNNNNNNNNNNNNNNNYYN
          FRONTROY     OP     DUMMEAD  500 KV    DIS            .000         .000       
          FRONTROY     L      FRO-MEAD 500 KV                   .000         .000       
          MEADOWBR     OP     MDL10    500 KV    CB             .000         .000       
          FRONTROY     OP     580T592  500 KV    CB             .000         .000       
          MEADOWBR     OP     ROYAL    500 KV    DIS            .000         .000       
          MEADOWBR     OP     MDL09    500 KV    CB             .000         .000       
          FRONTROY     OP     541T580  500 KV    CB             .000         .000       
11080    L500.BlackOak-Hatfield                            Y Y Y S Y Y N N     YNNNNNYNNNNYNNNNYNNYNNYYN YNNNNNYNNNNYNNNNYNNYNNYYN
          BLACKOAK     OP     BOL1 CB  500 KV    CB             .000         .000       
          HATFIELD     OP     HFL5 CB  500 KV    CB             .000         .000       
          HATFIELD     L      BLA-HAT  500 KV                   .000         .000       
          BLACKOAK     OP     BOL2 CB  500 KV    CB             .000         .000       
          HATFIELD     OP     HFL6 CB  500 KV    CB             .000         .000       
11090    L500.Cabot-Cranberry                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CABOT        OP     CB 01    500 KV    CB             .000         .000       
          CRANBERY     OP     B6       500 KV    CB             .000         .000       
          CABOT        OP     CB 02    500 KV    CB             .000         .000       
          CRANBERY     OP     DUMCABOT 500 KV    DIS            .000         .000       
          CABOT        OP     DUMCRAN  500 KV    DIS            .000         .000       
          CABOT        L      CAB-CRA  500 KV                   .000         .000       
          CRANBERY     OP     B5       500 KV    CB             .000         .000       
11100    Richmond - Westmoreland 6603 69 kV line           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RICH PE      OP     150 CB   69 KV     CB             .000         .000       
          WMORELAN     OP     30 CB    69 KV     CB             .000         .000       
          WMORELAN     OP     20 CB    69 KV     CB             .000         .000       
          RICH PE      L      RIC-WMO3 69 KV                    .000         .000       
          RICH PE      OP     140 CB   69 KV     CB             .000         .000       
11110    Richmond - Tacony 69 kV line                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RICH PE      OP     130 CB   69 KV     CB             .000         .000      P
          TACONY       OP     55 CB    69 KV     CB             .000         .000      P
          RICH PE      OP     120 CB   69 KV     CB             .000         .000      P
          RICH PE      L      RIC-TAC  69 KV                    .000         .000      P
11120    L69.Holmesburg-Tacony.6606                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOLMESBU     L      HOL-TAC  69 KV                    .000         .000      P
          TACONY       OP     65 CB    69 KV     CB             .000         .000      P
          HOLMESBU     X      HOL 9TR  138 KV                   .000         .000      P
          HOLMESBU     OP     065 CB   69 KV     CB             .000         .000      P
11130    Richmond - Westmoreland 6607 69 kV line           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RICH PE      OP     30 CB    69 KV     CB             .000         .000      P
          NPHILADE     OP     1TRLS CB 13 KV     CB             .000         .000      P
          RICH PE      OP     50CB     69 KV     CB             .000         .000      P
          WMORELAN     OP     6607 DIS 69 KV     DIS            .000         .000      P
          NPHILADE     OP     75 CB    69 KV     CB             .000         .000      P
          NPHILADE     L      NPH-WMO  69 KV                    .000         .000      P
          RICH PE      L      RIC-WMO7 69 KV                    .000         .000      P
          NPHILADE     OP     3TRLS CB 13 KV     CB             .000         .000      P
11140    L69.Master-Westmoreland.6626                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MASTER       L      MAS-WMO6 69 KV                    .000         .000      P
          WMORELAN     OP     60 CB    69 KV     CB             .000         .000      P
          MASTER       OP     265 CB   69 KV     CB             .000         .000      P
          MASTER       X      MAS 1TR  138 KV                   .000         .000      P
          WMORELAN     OP     50 CB    69 KV     CB             .000         .000      P
11150    Island Road - Sharon Hill 69 kV line              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ISLANDRD     OP     6645 CB  69 KV     CB             .000         .000      P
          SHARONHI     OP     6645 CB  69 KV     CB             .000         .000      P
          ISLANDRD     L      ISL-SHA  69 KV                    .000         .000      P
11160    Blueball - Chichester 69 kV line                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BLUEBALL     OP     135 CB   69 KV     CB             .000         .000      P
          CHICHEST     OP     485 CB   69 KV     CB             .000         .000      P
          BLUEBALL     L      BLU-CHI  69 KV                    .000         .000      P
          BLUEBALL     OP     235 CB   69 KV     CB             .000         .000      P
11170    Chester - Chichester 69 kV line                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHESTER      OP     60 CB    69 KV     CB             .000         .000      P
          CHICHEST     OP     525      69 KV     CB             .000         .000      P
          CHESTER      L      CHE-CHI  69 KV                    .000         .000      P
          CHESTER      OP     10 CB    69 KV     CB             .000         .000      P
11180    Chester - Scott Paper 69 kV line                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHESTER      OP     50 CB    69 KV     CB             .000         .000      P
          CHESTER      OP     20 CB    69 KV     CB             .000         .000      P
          SCOTTPAP     OP     595 CB   69 KV     CB             .000         .000      P
          CHESTER      L      CHE-SCO  69 KV                    .000         .000      P
11190    Angora #1 69/13 kV Transformer                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ANGORA       OP     1TRHS CB 69 KV     CB             .000         .000      P
          ANGORA       OP     1TRLS CB 13 KV     CB             .000         .000      P
          ANGORA       X      ANG 1TR  69 KV                    .000         .000      P
11200    Angora #2 69/13 kV Transformer                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ANGORA       OP     2TRHS CB 69 KV     CB             .000         .000       
          ANGORA       OP     2TRLS CB 13 KV     CB             .000         .000       
          ANGORA       X      ANG 2TR  69 KV                    .000         .000       
11210    Blue Ball #1 69/13 kV Transformer                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BLUEBALL     OP     135 CB   69 KV     CB             .000         .000      P
          BLUEBALL     OP     145 CB   69 KV     CB             .000         .000      P
          BLUEBALL     OP     1TRLSCB  13 KV     CB             .000         .000      P
          BLUEBALL     X      1TR      69 KV                    .000         .000      P
11220    Blue Ball #2 69/13 kV Transformer                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BLUEBALL     OP     235 CB   69 KV     CB             .000         .000      P
          BLUEBALL     OP     255 CB   69 KV     CB             .000         .000      P
          BLUEBALL     X      2TR      69 KV                    .000         .000      P
          BLUEBALL     OP     2TRLSCB  13 KV     CB             .000         .000      P
11230    Bradford #1 230/35 kV Transformer                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRADFORD     OP     115 CB   35 KV     CB             .000         .000       
          BRADFORD     OP     15 CB    230 KV    CB             .000         .000       
          BRADFORD     X      BRAD1TR  230 KV                   .000         .000       
11240    Bradford #2 230/35 kV Transformer                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRADFORD     OP     25 CB    230 KV    CB             .000         .000      P
          BRADFORD     X      BRAD2TR  230 KV                   .000         .000      P
          BRADFORD     OP     225-CB   35 KV     CB             .000         .000      P
11250    Buckingham #2 230/35 kV Transformer               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BUCKINGH     OP     325 CB   35 KV     CB             .000         .000      P
          BUCKINGH     OP     195 CB   230 KV    CB             .000         .000      P
          BUCKINGH     L      BUC-WAR  230 KV                   .000         .000      P
          BUCKINGH     X      BUCK4TR  230 KV                   .000         .000      P
          BUCKINGH     OP     40 CB    35 KV     CB             .000         .000      P
          BUCKINGH     X      BUCK2TR  230 KV                   .000         .000      P
          BUCKINGH     OP     20       35 KV     CB             .000         .000      P
          WARRINGT     OP     195 CB   230 KV    CB             .000         .000      P
          BUCKINGH     OP     220 CB   230 KV    CB             .000         .000      P
11260    Buckingham #3 230/35 kV Transformer               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BUCKINGH     X      BUCK5TR  230 KV                   .000         .000      P
          BUCKINGH     L      BUC-WRM  230 KV                   .000         .000      P
          BUCKINGH     OP     210 CB   230 KV    CB             .000         .000      P
          WARMINST     OP     125 CB   230 KV    CB             .000         .000      P
          WARMINST     OP     13TRLS C 13 KV     CB             .000         .000      P
          BUCKINGH     OP     30       35 KV     CB             .000         .000      P
          BUCKINGH     OP     50 CB    35 KV     CB             .000         .000      P
          WARMINST     X      WRM13TR  230 KV                   .000         .000      P
          BUCKINGH     OP     325 CB   35 KV     CB             .000         .000      P
          BUCKINGH     X      BUCK3TR  230 KV                   .000         .000      P
11270    Byberry #2 138/35 kV Transformer                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BYBERRY      OP     100 CB   138 KV    CB             .000         .000      P
          BYBERRY      X      BYB 2TR  138 KV                   .000         .000      P
          BYBERRY      OP     90 CB    35 KV     CB             .000         .000      P
11280    Chester 38TR 35/13 kV Transformer                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHESTER      X      CHE38TR  35 KV                    .000         .000      P
          CHESTER      OP     125      13 KV     CB             .000         .000      P
          CHESTER      OP     385 CB   35 KV     CB             .000         .000      P
11290    Chester 48TR 69/35 kV Transformer                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHESTER      OP     395 CB   35 KV     CB             .000         .000      P
          CHESTER      X      CHE48TR  69 KV                    .000         .000      P
          CHESTER      OP     485 CB   69 KV     CB             .000         .000      P
11300    Chester 52TR 69/35 kV Transformer                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHESTER      OP     165      13 KV     CB             .000         .000      P
          CHESTER      OP     50 CB    69 KV     CB             .000         .000      P
          CHESTER      X      CHE52TR  69 KV                    .000         .000      P
          CHESTER      OP     60 CB    69 KV     CB             .000         .000      P
11310    Chichester 7TR 138/69 kV Transformer              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHICHEST     OP     775 CB   138 KV    CB             .000         .000      P
          CHICHEST     X      CHI 7TR  138 KV                   .000         .000      P
          CHICHEST     OP     175 CB   69 KV     CB             .000         .000      P
11320    Chichester 8TR 138/69 kV Transformer              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHICHEST     X      CHI 8TR  138 KV                   .000         .000      P
          CHICHEST     OP     885 CB   138 KV    CB             .000         .000      P
          CHICHEST     OP     285 CB   69 KV     CB             .000         .000      P
11340    Croydon CROY1 230/13 kV Transformer               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROYDON      OP     015 CB   230 KV    CB             .000         .000      P
          CROYDON      OP     1TRLS CB 13 KV     CB             .000         .000      P
          CROYDON      X      CROY 1   230 KV                   .000         .000      P
11350    Croydon CROY3 230/13 kV Transformer               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROYDON      X      CROY 3   230 KV                   .000         .000      P
          CROYDON      OP     3TRLS CB 13 KV     CB             .000         .000      P
          CROYDON      OP     035 CB   230 KV    CB             .000         .000      P
11360    L230.Concord-Foulk.220-67 + 230/13.Foulk.T1       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FOULK        OP     1TRLS CB 13 KV     CB             .000         .000       
          CONC PE      L      CON-FOU  230 KV                   .000         .000       
          CONC PE      OP     565 CB   230 KV    CB             .000         .000       
          CONC PE      X      CON 2TR  230 KV                   .000         .000       
          FOULK        OP     785 CB   230 KV    CB             .000         .000       
          FOULK        X      FOU 1TR  230 KV                   .000         .000       
          CONC PE      OP     225 CB   35 KV     CB             .000         .000       
11370    Foulk 2TR 230/13 kV Transformer                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FOULK        OP     785 CB   230 KV    CB             .000         .000      P
          CHICHEST     OP     045 CB   230 KV    CB             .000         .000      P
          FOULK        X      FOU 2TR  230 KV                   .000         .000      P
          CHICHEST     L      CHI-FOU  230 KV                   .000         .000      P
          FOULK        OP     2TRLS CB 13 KV     CB             .000         .000      P
11380    Grays Ferry 2TRAN 230/13 kV Transformer           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GRAYSFER     OP     2TRLS    13 KV     CB             .000         .000       
          GRAYSFER     X      2TRAN    230 KV                   .000         .000       
          GRAYSFER     OP     25 CB    230 KV    CB             .000         .000       
11390    Jenkintown JENK12T 230/13 kV Transformer          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JENKINTO     OP     12TRLSCB 13 KV     CB             .000         .000       
          JENKINTO     OP     240      230 KV    CB             .000         .000       
          JENKINTO     X      JENK12T  230 KV                   .000         .000       
11400    Island Road 6TR 230/69 kV Transformer             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ISLANDRD     OP     665 CB   230 KV    CB             .000         .000      P
          ISLANDRD     OP     65 CB    69 KV     CB             .000         .000      P
          ISLANDRD     X      IR 6TR   230 KV                   .000         .000      P
11410    Llanerch 5TR 138/35 kV Transformer                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LLANERCH     X      LAN 5TR  138 KV                   .000         .000      P
          LLANERCH     OP     515 CB   35 KV     CB             .000         .000      P
          LLANERCH     OP     555 CB   138 KV    CB             .000         .000      P
11420    Llanerch 6TR 138/35 kV Transformer                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LLANERCH     OP     665 CB   138 KV    CB             .000         .000      P
          LLANERCH     X      LAN 6TR  138 KV                   .000         .000      P
          LLANERCH     OP     635 CB   35 KV     CB             .000         .000      P
11430    Llanerch 11TR 138/35 kV Transformer               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LLANERCH     OP     12-11    13 KV     CB             .000         .000      P
          LLANERCH     X      LAN 11TR 138 KV                   .000         .000      P
          LLANERCH     OP     155 CB   138 KV    CB             .000         .000      P
11460    Marcus Hook 3TR 69/13 kV Transformer              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MARCUSHO     X      MAR 3TR  69 KV                    .000         .000      P
          MARCUSHO     OP     3TRLS CB 13 KV     CB             .000         .000      P
          MARCUSHO     OP     3TRHS CB 69 KV     CB             .000         .000      P
11470    Marcus Hook 4TR 69/13 kV Transformer              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MARCUSHO     OP     4TRHS CB 69 KV     CB             .000         .000      P
          MARCUSHO     OP     4TRLS CB 13 KV     CB             .000         .000      P
          MARCUSHO     X      MAR 4TR  69 KV                    .000         .000      P
11500    Newlinville 1TR 230/35 kV Transformer             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NEWLINVI     OP     40 CB    35 KV     CB             .000         .000      P
          NEWLINVI     OP     220 CB   230 KV    CB             .000         .000      P
          NEWLINVI     X      NEW 1TR  230 KV                   .000         .000      P
11510    230/138.PlymouthMeeting.T6                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PLYMOUTH     OP     865 CB   138 KV    CB             .000         .000       
          PLYMOUTH     OP     265 CB   230 KV    CB             .000         .000       
          PLYMOUTH     X      PLY 6TR  230 KV                   .000         .000       
11540    Schuylkill 5TR 69/13 kV Transformer               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SCHUYLKI     OP     340 CB   69 KV     CB             .000         .000       
          SCHUYLKI     OP     5TRLS CB 13 KV     CB             .000         .000       
          SCHUYLKI     OP     330 CB   69 KV     CB             .000         .000       
          SCHUYLKI     X      SCH 5TR  69 KV                    .000         .000       
11560    Upper Merion 11TR 230/13 kV Transformer           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          UPPERMER     X      UP 3TR   230 KV                   .000         .000       
          TREDYFFR     L      TRE-UPP9 230 KV                   .000         .000       
          PLANEBRO     OP     095      230 KV    CB             .000         .000       
          PLANEBRO     L      PLA-TRE9 230 KV                   .000         .000       
          TREDYFFR     OP     95 CB    230 KV    DIS            .000         .000       
          UPPERMER     OP     15 CB    13 KV     CB             .000         .000       
          UPPERMER     X      UP 11TR  230 KV                   .000         .000       
          UPPERMER     OP     355 CB   230 KV    CB             .000         .000       
          UPPERMER     OP     30 CB    35 KV     CB             .000         .000       
11580    Waneeta 1TR 230/13 kV Transformer                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WANEETA      OP     145 CB   230 KV    CB             .000         .000      P
          WANEETA      OP     1TRLS CB 13 KV     CB             .000         .000      P
          WANEETA      X      WAN 1TR  230 KV                   .000         .000      P
11590    Waneeta 3TR 230/13 kV Transformer                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WANEETA      OP     3TRLS CB 13 KV     CB             .000         .000      P
          WANEETA      OP     365 CB   230 KV    CB             .000         .000      P
          WANEETA      X      WAN 3TR  230 KV                   .000         .000      P
11620    Warrington 1TR 230/35 kV Transformer              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WARRINGT     OP     195 CB   230 KV    CB             .000         .000       
          BUCKINGH     L      BUC-WAR  230 KV                   .000         .000       
          WARRINGT     X      WAR 1TR  230 KV                   .000         .000       
          WARRINGT     OP     115 CB   35 KV     CB             .000         .000       
          WARRINGT     OP     875 CB   230 KV    CB             .000         .000       
11630    Warrington 3TR 230/35 kV Transformer              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARTMAN      L      HAR-WAR  230 KV                   .000         .000       
          WARRINGT     OP     585 CB   230 KV    CB             .000         .000       
          WARRINGT     X      WAR 3TR  230 KV                   .000         .000       
          WARRINGT     OP     875 CB   230 KV    CB             .000         .000       
          WARRINGT     OP     35 CB    230 KV    DIS            .000         .000       
          WARRINGT     OP     315 CB   35 KV     CB             .000         .000       
11650    Westmoreland 12TR 230/13 kV Transformer           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WMORELAN     OP     2TR LS   13 KV     CB             .000         .000       
          WMORELAN     OP     705 CB   230 KV    CB             .000         .000       
          WMORELAN     OP     2TRDUMMY 13 KV     CB             .000         .000       
          WMORELAN     X      12TR     230 KV                   .000         .000       
          WMORELAN     OP     905 CB   230 KV    CB             .000         .000       
11670    Whitemarsh 8TR 69/35 kV Transformer               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WHITEMAR     OP     20 CB    35 KV     CB             .000         .000       
          WHITEMAR     OP     185 CB   69 KV     CB             .000         .000       
          WHITEMAR     X      WHIT8TR  69 KV                    .000         .000       
11680    69/35.Woodlyn.2TR                                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WOODLYN      OP     45 CB    69 KV     CB             .000         .000       
          WOODLYN      X      WOD 2TR  69 KV                    .000         .000       
          WOODLYN      OP     25 CB    35 KV     CB             .000         .000       
11690    Emilie EML8CP 230 kV Capacitor                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EMILIE       CP     EML 8-1  230 KV                   .000         .000       
          EMILIE       OP     815 CB   230 KV    CB             .000         .000       
11700    Grays Ferry 8-1 230 kV Capacitor                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GRAYSFER     OP     815 CB   230 KV    CB             .000         .000       
          GRAYSFER     CP     CAP1     230 KV                   .000         .000       
11710    Grays Ferry 8-2 230 kV Capacitor                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GRAYSFER     CP     CAP2     230 KV                   .000         .000       
          GRAYSFER     OP     825CB    230 KV    CB             .000         .000       
11720    Limerick LI3-1 500 kV Capacitor                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LIMERICK     OP     345 CB   500 KV    CB             .000         .000       
          LIMERICK     CP     LI 3-1   500 KV                   .000         .000       
          LIMERICK     OP     355 CB   500 KV    CB             .000         .000       
11730    Plymouth Meeting PL1-6 230 kV Capacitor           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PLYMOUTH     CP     PL 1-6   230 KV                   .000         .000       
          PLYMOUTH     OP     165 CB   230 KV    CB             .000         .000       
11740    Waneeta WA2-1 230 kV Capacitor                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WANEETA      OP     205 CB   230 KV    CB             .000         .000      P
          WANEETA      CP     WA 2-1   230 KV                   .000         .000      P
11750    Whitpain CAP1 230 kV Capacitor                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WHITPAIN     CP     CAP1     230 KV                   .000         .000      P
          WHITPAIN     OP     245 CB   230 KV    CB             .000         .000      P
11760    Whitpain CAP2 230 kV Capacitor                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WHITPAIN     OP     255 CB   230 KV    CB             .000         .000      P
          WHITPAIN     CP     CAP2     230 KV                   .000         .000      P
11770    Chester #7 CT                                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHESTER      U      UNIT 7   13 KV                    .000         .000       
          CHESTER      OP     7 CT CB  13 KV     CB             .000         .000       
11780    Chester #8 CT                                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHESTER      OP     8 CT CB  13 KV     CB             .000         .000       
          CHESTER      U      UNIT 8   13 KV                    .000         .000       
11790    Chester #9 CT                                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHESTER      U      UNIT 9   13 KV                    .000         .000      P
          CHESTER      OP     9 CT CB  13 KV     CB             .000         .000      P
11800    Eddystone #10 CT                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDDYSTON     U      UNIT10   13 KV                    .000         .000      P
          EDDYSTON     OP     105 CB   138 KV    CB             .000         .000      P
          EDDYSTON     X      EDD 10A  138 KV                   .000         .000      P
11810    Eddystone #20 CT                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDDYSTON     OP     205 CB   138 KV    CB             .000         .000      P
          EDDYSTON     X      EDDY20A  138 KV                   .000         .000      P
          EDDYSTON     U      UNIT20   13 KV                    .000         .000      P
11820    Elmwood - Grays Ferry 230 kV line                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GRAYSFER     OP     375 CB   230 KV    CB             .000         .000      P
          ELMWOOD      X      6TR      230 KV                   .000         .000      P
          ELMWOOD      OP     6TRLS    13 KV     CB             .000         .000      P
          ELMWOOD      L      ELM-GRA  230 KV                   .000         .000      P
          ELMWOOD      OP     785 CB   230 KV    CB             .000         .000      P
          GRAYSFER     OP     3TRLS    13 KV     CB             .000         .000      P
          GRAYSFER     X      3TRAN    230 KV                   .000         .000      P
11830    L230.Elmwood-MacDade.220-40                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ELMWOOD      OP     4TRLS    13 KV     CB             .000         .000       
          ELMWOOD      X      4TR      230 KV                   .000         .000       
          MACDADE      X      MCDADE3  230 KV                   .000         .000       
          MACDADE      OP     3TRLS CB 13 KV     CB             .000         .000       
          ELMWOOD      L      ELM-MAC  230 KV                   .000         .000       
          MACDADE      OP     805 CB   230 KV    CB             .000         .000       
          ELMWOOD      OP     785 CB   230 KV    CB             .000         .000       
11840    L230.Printz-Ridley-Morton-MacDade.220-46          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PRINTZ       L      PRI-RID  230 KV                   .000         .000      P
          MORTON       X      MORTON2  230 KV                   .000         .000      P
          MORTON       OP     565 CB   230 KV    CB             .000         .000      P
          MACDADE      L      MAC-RID  230 KV                   .000         .000      P
          MORTON       L      MOR-RID  230 KV                   .000         .000      P
          MACDADE      X      MCDADE1  230 KV                   .000         .000      P
          MACDADE      OP     905 CB   230 KV    CB             .000         .000      P
          MORTON       OP     2TRLS CB 13 KV     CB             .000         .000      P
          PRINTZ       OP     115      230 KV    CB             .000         .000      P
          MACDADE      OP     1TRLS CB 13 KV     CB             .000         .000      P
          PRINTZ       OP     125      230 KV    CB             .000         .000      P
11850    Eddystone-Printz 230 kV line                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PRINTZ       OP     315      230 KV    CB             .000         .000       
          PRINTZ       OP     225      230 KV    CB             .000         .000       
          EDDYSTON     OP     785 CB   230 KV    CB             .000         .000       
          EDDYSTON     L      EDD-PRI  230 KV                   .000         .000       
11860    Printz (Liberty) GTG2                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PRINTZ       OP     DUM B    18 KV     CB             .000         .000      P
          PRINTZ       U      GTG2     18 KV                    .000         .000      P
11870    Printz (Liberty) GTG1                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PRINTZ       OP     DUM A    18 KV     CB             .000         .000      P
          PRINTZ       U      GTG1     18 KV                    .000         .000      P
11880    Printz (Liberty) STG                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PRINTZ       U      STG      18 KV                    .000         .000      P
          PRINTZ       OP     DUM C    18 KV     CB             .000         .000      P
11890    L230.Emilie-Eddington-Croydon                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDDINGTO     OP     6TRLS CB 13 KV     CB             .000         .000       
          EMILIE       OP     80 CB    35 KV     CB             .000         .000       
          EDDINTAP     L      EDD-EDD  230 KV                   .000         .000       
          EMILIE       OP     555 CB   230 KV    CB             .000         .000       
          CROYDON      L      CRO-EDD  230 KV                   .000         .000       
          EMILIE       X      EMIL5TR  230 KV                   .000         .000       
          EDDINGTO     X      EDNG6TR  230 KV                   .000         .000       
          CROYDON      OP     335 CB   230 KV    CB             .000         .000       
          CROYDON      OP     235 CB   230 KV    CB             .000         .000       
          EDDINGTO     OP     125 CB   230 KV    CB             .000         .000       
          EDDINTAP     L      EDD-EMI  230 KV                   .000         .000       
11910    L230.IslandRoad-Penrose                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ISLANDRD     OP     8TRLS CB 13 KV     CB             .000         .000      P
          ISLANDRD     OP     235 CB   230 KV    CB             .000         .000      P
          ISLANDRD     X      IR 8TR   230 KV                   .000         .000      P
          PENROSE      OP     345      230 KV    CB             .000         .000      P
          ISLANDRD     L      ISL-PEN  230 KV                   .000         .000      P
          ISLANDRD     X      IR 6TR   230 KV                   .000         .000      P
          ISLANDRD     OP     665 CB   230 KV    CB             .000         .000      P
          PENROSE      OP     745      230 KV    CB             .000         .000      P
11920    230/13.GraysFerry.TR1 & GraysFerry.1Gen.1CT       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GRAYFR_1     X      1TR      230 KV                   .000         .000       
          GRAYFR_1     U      1 CT     13 KV                    .000         .000       
          GRAYFR_1     OP     XF1 LS   13 KV     CB             .000         .000       
          GRAYFR_1     L      GRA-GRA  230 KV                   .000         .000       
          GRAYFR_1     U      1 GEN    13 KV                    .000         .000       
          GRAYFR_1     OP     22076CB  230 KV    CB             .000         .000       
11930    Montco - Plymouth Meeting 138 kV line             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PLYMOUTH     OP     345 CB   138 KV    CB             .000         .000       
          MONTCO       OP     LOAD CB  13 KV     CB             .000         .000       
          MONTCO       OP     1TRHS CB 138 KV    CB             .000         .000       
          MONTCO       L      MON-PLY  138 KV                   .000         .000       
          MONTCO       U      MONTCO   13 KV                    .000         .000       
11940    Bryn Mawr - Plymouth Meeting 138 kV line          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRYNMAWR     OP     19TRLS   13 KV     CB             .000         .000       
          BRYNMAWR     L      BRY-PLY  138 KV                   .000         .000       
          PLYMOUTH     OP     355 CB   138 KV    CB             .000         .000       
          BRYNMAWR     OP     160 CB   35 KV     CB             .000         .000       
          BRYNMAWR     X      19TR     138 KV                   .000         .000       
          BRYNMAWR     X      BRYNMR1  138 KV                   .000         .000       
          BRYNMAWR     OP     100 CB   138 KV    CB             .000         .000       
11950    Bryn Mawr - Llanerch 138 kV line                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRYNMAWR     OP     20TRLS   13 KV     CB             .000         .000       
          LLANERCH     OP     13-12    13 KV     CB             .000         .000       
          BRYNMAWR     X      BRYNMR3  138 KV                   .000         .000       
          LLANERCH     X      LAN 12TR 138 KV                   .000         .000       
          LLANERCH     OP     12-11    13 KV     CB             .000         .000       
          LLANERCH     OP     365 CB   138 KV    CB             .000         .000       
          BRYNMAWR     OP     110 CB   138 KV    CB             .000         .000       
          BRYNMAWR     OP     130 CB   35 KV     CB             .000         .000       
          BRYNMAWR     X      20TR     138 KV                   .000         .000       
          BRYNMAWR     L      BRY-LLA  138 KV                   .000         .000       
11960    L138.Eddystone-Woodlyn + 138/69.Woodlyn.4TR       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WOODLYN      OP     45 CB    69 KV     CB             .000         .000       
          EDDYSTON     OP     415 CB   138 KV    CB             .000         .000       
          EDDYSTON     L      EDD-WOO  138 KV                   .000         .000       
          WOODLYN      X      WOD 4TR  138 KV                   .000         .000       
11970    Eddystone - Llanerch 130-42 138 kV line           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDDYSTON     OP     255      138 KV    CB             .000         .000       
          EDDYSTON     L      EDD-LLA2 138 KV                   .000         .000       
          LLANERCH     OP     425 CB   138 KV    CB             .000         .000       
11980    Eddystone - Llanerch 130-45 138 kV line           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDDYSTON     L      EDD-LLA5 138 KV                   .000         .000       
          LLANERCH     OP     13-12    13 KV     CB             .000         .000       
          LLANERCH     OP     455 CB   138 KV    CB             .000         .000       
          LLANERCH     X      LAN 13TR 138 KV                   .000         .000       
          EDDYSTON     OP     455      138 KV    CB             .000         .000       
11990    L69.Burholme - Dluzerne                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WANEETA      X      WAN 9TR  138 KV                   .000         .000       
          RICH PE      OP     60 CB    69 KV     CB             .000         .000       
          BURHOLME     X      BUR1TR   69 KV                    .000         .000       
          WANEETA      OP     905 CB   69 KV     CB             .000         .000       
          DLUZERNE     L      DLU-WAN  69 KV                    .000         .000       
          BURHOLME     OP     1TRLS CB 13 KV     CB             .000         .000       
          BURHOLME     L      BUR-DLU  69 KV                    .000         .000       
          WANEETA      OP     895 CB   138 KV    CB             .000         .000       
          BURHOLME     X      BUR5TR   69 KV                    .000         .000       
          BURHOLME     OP     5TRLS CB 13 KV     CB             .000         .000       
          RICH PE      OP     50CB     69 KV     CB             .000         .000       
          BURHOLME     OP     260 CB   69 KV     CB             .000         .000       
          BURHOLME     OP     3TRLS CB 13 KV     CB             .000         .000       
          DLUZERNE     L      DLU-RIC  69 KV                    .000         .000       
          BURHOLME     X      BUR3TR   69 KV                    .000         .000       
          BURHOLME     OP     135THSCB 69 KV     DIS            .000         .000       
12000    L69.Master - University                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          UNIVERSI     OP     4TRLSBKR 13 KV     CB             .000         .000       
          MASTER       OP     245 CB   138 KV    CB             .000         .000       
          MASTER       X      MAS 4TR  138 KV                   .000         .000       
          MASTER       L      MAS-UNI  69 KV                    .000         .000       
          UNIVERSI     OP     785 CB   69 KV     CB             .000         .000       
          UNIVERSI     X      4TR      69 KV                    .000         .000       
12010    L69.Schuylkill - University                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SCHUYLKI     L      SCH-UNI  69 KV                    .000         .000       
          SCHUYLKI     OP     340 CB   69 KV     CB             .000         .000       
          UNIVERSI     X      3TR      69 KV                    .000         .000       
          UNIVERSI     OP     785 CB   69 KV     CB             .000         .000       
          SCHUYLKI     OP     350 CB   69 KV     CB             .000         .000       
          UNIVERSI     OP     3TRLSBKR 13 KV     CB             .000         .000       
12020    L69.Burholme - Byberry                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BYBERRY      X      BYB4TR   138 KV                   .000         .000       
          BURHOLME     OP     260 CB   69 KV     CB             .000         .000       
          BURHOLME     X      BUR2TR   69 KV                    .000         .000       
          BYBERRY      OP     70 CB    69 KV     CB             .000         .000       
          BURHOLME     OP     6TRLS CB 13 KV     CB             .000         .000       
          BURHOLME     OP     2TRLS CB 13 KV     CB             .000         .000       
          BURHOLME     OP     246THSCB 69 KV     DIS            .000         .000       
          BURHOLME     L      BUR-BYB  69 KV                    .000         .000       
          BURHOLME     X      BUR6TR   69 KV                    .000         .000       
          BURHOLME     X      BUR4TR   69 KV                    .000         .000       
          BURHOLME     OP     4TRLS CB 13 KV     CB             .000         .000       
          BYBERRY      X      BYB3TR   138 KV                   .000         .000       
12030    L69.Schuylkill-Penn.6621                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PENN         S      PENN     69 KV                    .000         .000       
          SCHUYLKI     OP     110 CB   69 KV     CB             .000         .000       
          PENN         L      PEN-SCH1 69 KV                    .000         .000       
          PENN         LD     1BUS     69 KV                    .000         .000       
          SCHUYLKI     OP     170 CB   69 KV     CB             .000         .000       
12040    L69.Island Road - Schuylkill                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ISLANDRD     X      IR 3TR   69 KV                    .000         .000       
          ISLANDRD     OP     3TRHSDIS 69 KV     CB             .000         .000       
          ISLANDRD     OP     6623 CB  69 KV     CB             .000         .000       
          ISLANDRD     X      IR 1TR   69 KV                    .000         .000       
          ISLANDRD     L      ISL-SCH  69 KV                    .000         .000       
          SCHUYLKI     OP     250 CB   69 KV     CB             .000         .000       
          ISLANDRD     OP     1TRHSDIS 69 KV     CB             .000         .000       
          SCHUYLKI     OP     260 CB   69 KV     CB             .000         .000       
12050    L69.Angora - Schuylkill                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ANGORA       OP     2TRHS CB 69 KV     CB             .000         .000       
          SCHUYLKI     OP     120 CB   69 KV     CB             .000         .000       
          ANGORA       OP     2TRLS CB 13 KV     CB             .000         .000       
          ANGORA       OP     210 CB   69 KV     CB             .000         .000       
          SCHUYLKI     OP     130 CB   69 KV     CB             .000         .000       
          ANGORA       X      ANG 2TR  69 KV                    .000         .000       
          ANGORA       L      ANG-SCH  69 KV                    .000         .000       
12060    L69.Lombard - Schuylkill.6627                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SCHUYLKI     OP     250 CB   69 KV     CB             .000         .000       
          LOMBARD      L      LOM-SCH7 69 KV                    .000         .000       
          LOMBARD      X      LOM 1TR  69 KV                    .000         .000       
          LOMBARD      OP     8TRLS CB 13 KV     CB             .000         .000       
          LOMBARD      OP     1TRLS CB 13 KV     CB             .000         .000       
          LOMBARD      X      LOM 8TR  69 KV                    .000         .000       
          SCHUYLKI     OP     240 CB   69 KV     CB             .000         .000       
12070    L69.Penn - Schuylkill.6628                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PENN         S      PENN     69 KV                    .000         .000       
          SCHUYLKI     OP     210 CB   69 KV     CB             .000         .000       
          PENN         OP     T2 DIS   69 KV     DIS            .000         .000       
          SCHUYLKI     OP     220 CB   69 KV     CB             .000         .000       
          PENN         LD     3BUS     69 KV                    .000         .000       
          PENN         L      PEN-SCH8 69 KV                    .000         .000       
12080    L69.Angora - Upper Darby                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ANGORA       OP     210 CB   69 KV     CB             .000         .000       
          UPPERDAR     LD     13TR     69 KV                    .000         .000       
          ANGORA       OP     1TRLS CB 13 KV     CB             .000         .000       
          ANGORA       X      ANG 1TR  69 KV                    .000         .000       
          ANGORA       OP     1TRHS CB 69 KV     CB             .000         .000       
          UPPERDAR     OP     295 CB   69 KV     CB             .000         .000       
          ANGORA       L      ANG-UPP  69 KV                    .000         .000       
12090    L69.Passyunk - Schuylkill.6630                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SCHUYLKI     OP     360 CB   69 KV     CB             .000         .000       
          PASSYUNK     OP     4TRLS CB 13 KV     CB             .000         .000       
          PASSYUNK     OP     1TRLS CB 13 KV     CB             .000         .000       
          SCHUYLKI     OP     310 CB   69 KV     CB             .000         .000       
          PASSYUNK     X      PAS 1TR  69 KV                    .000         .000       
          PASSYUNK     X      PAS 4TR  69 KV                    .000         .000       
          PASSYUNK     L      PAS-SCH0 69 KV                    .000         .000       
12100    L69.Passyunk - Schuylkill.6631                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PASSYUNK     X      PAS 5TR  69 KV                    .000         .000       
          PASSYUNK     L      PAS-SCH1 69 KV                    .000         .000       
          PASSYUNK     X      PAS 2TR  69 KV                    .000         .000       
          PASSYUNK     OP     5TRLS CB 13 KV     CB             .000         .000       
          PASSYUNK     OP     235 CB   69 KV     CB             .000         .000       
          SCHUYLKI     OP     220 CB   69 KV     CB             .000         .000       
          PASSYUNK     OP     2TRLS CB 13 KV     CB             .000         .000       
          SCHUYLKI     OP     230 CB   69 KV     CB             .000         .000       
12110    L69.Lombard - Schuylkill.6632                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SCHUYLKI     OP     330 CB   69 KV     CB             .000         .000       
          LOMBARD      X      LOM 3TR  69 KV                    .000         .000       
          LOMBARD      L      LOM-SCH2 69 KV                    .000         .000       
          LOMBARD      OP     3TR2LSCB 13 KV     CB             .000         .000       
          LOMBARD      X      LOM 6TR  69 KV                    .000         .000       
          LOMBARD      OP     6TR7LSCB 13 KV     CB             .000         .000       
          LOMBARD      OP     6TR6LSCB 13 KV     CB             .000         .000       
          LOMBARD      OP     3TR3LSCB 13 KV     CB             .000         .000       
          SCHUYLKI     OP     320 CB   69 KV     CB             .000         .000       
12120    L69.Packer - Southwark                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PACKER       L      PAC-SWA  69 KV                    .000         .000       
          PACKER       OP     785 CB   69 KV     CB             .000         .000       
          PACKER       LD     LD2      69 KV                    .000         .000       
          SWARK        OP     125 CB   69 KV     CB             .000         .000       
12130    L69.Tuna-Delaware-Southwark                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DELA PE      S      6636REAC 69 KV                    .000         .000       
          SWARK        X      SWK34TR  69 KV                    .000         .000       
          SWARK        OP     375 CB   69 KV     CB             .000         .000       
          TUNA         OP     150      69 KV     CB             .000         .000       
          DELA PE      L      DEL-TUN6 69 KV                    .000         .000       
          DELA PE      OP     1TRLS CB 13 KV     CB             .000         .000       
          SWARK        U      UNIT4    13 KV                    .000         .000       
          SWARK        OP     125 CB   69 KV     CB             .000         .000       
          SWARK        U      UNIT3    13 KV                    .000         .000       
          DELA PE      L      DEL-SWA  69 KV                    .000         .000       
          TUNA         OP     140      69 KV     CB             .000         .000       
          DELA PE      X      DEL 1TR  69 KV                    .000         .000       
12140    L69.Tuna-NorthPhiladelphia.6638                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NPHILADE     OP     2TRLS CB 13 KV     CB             .000         .000       
          TUNA         OP     160      69 KV     CB             .000         .000       
          NPHILADE     X      NP 2TR   69 KV                    .000         .000       
          NPHILADE     OP     4TRLS CB 13 KV     CB             .000         .000       
          NPHILADE     OP     85 CB    69 KV     CB             .000         .000       
          TUNA         OP     387      69 KV     DIS            .000         .000       
          TUNA         OP     110      69 KV     CB             .000         .000       
          NPHILADE     X      NP 4TR   69 KV                    .000         .000       
          NPHILADE     X      NP 8TR   230 KV                   .000         .000       
          TUNA         L      NPH-TUN  69 KV                    .000         .000       
12150    L69.North Philadelphia - Westmoreland             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NPHILADE     OP     75 CB    69 KV     CB             .000         .000       
          NPHILADE     X      NP 7TR   230 KV                   .000         .000       
          RICH PE      L      RIC-WMO7 69 KV                    .000         .000       
          RICH PE      OP     140 CB   69 KV     CB             .000         .000       
          RICH PE      OP     150 CB   69 KV     CB             .000         .000       
          NPHILADE     OP     3TRLS CB 13 KV     CB             .000         .000       
          NPHILADE     X      NP 3TR   69 KV                    .000         .000       
          NPHILADE     OP     1TRLS CB 13 KV     CB             .000         .000       
          NPHILADE     X      NP 1TR   69 KV                    .000         .000       
          NPHILADE     L      NPH-WMO  69 KV                    .000         .000       
12160    L69.Island Road - Packer                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PACKER       OP     785 CB   69 KV     CB             .000         .000       
          PACKER       LD     LD1      69 KV                    .000         .000       
          ISLANDRD     L      ISL-PAC  69 KV                    .000         .000       
          ISLANDRD     OP     6641 CB  69 KV     CB             .000         .000       
12170    L69.Chichester - Marcus Hook                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHICHEST     OP     515 CB   69 KV     CB             .000         .000       
          MARCUSHO     OP     200 CB   69 KV     CB             .000         .000       
          MARCUSHO     OP     4TRLS CB 13 KV     CB             .000         .000       
          CHICHEST     L      CHI-MAR  69 KV                    .000         .000       
          MARCUSHO     X      MAR 4TR  69 KV                    .000         .000       
12180    L69.Chester - Marcus Hook.6653                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MARCUSHO     X      MAR 3TR  69 KV                    .000         .000       
          BLUEBALL     L      BLU-BLU  69 KV                    .000         .000       
          MARCUSHO     OP     3TRLS CB 13 KV     CB             .000         .000       
          CHESTER      OP     535 CB   69 KV     CB             .000         .000       
          BLUEBALL     OP     255 CB   69 KV     CB             .000         .000       
          MARCUSHO     OP     200 CB   69 KV     CB             .000         .000       
          BLUE TAP     L      BLU-MAR  69 KV                    .000         .000       
          BLUEBALL     OP     455 CB   69 KV     CB             .000         .000       
          BLUE TAP     L      BLU-CHE  69 KV                    .000         .000       
12190    L69.Llanerch - Upper Darby                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LLANERCH     OP     575 CB   69 KV     CB             .000         .000       
          LLANERCH     L      LLA-UPP  69 KV                    .000         .000       
          LLANERCH     X      LAN 7TR  138 KV                   .000         .000       
          LLANERCH     OP     755 CB   138 KV    CB             .000         .000       
          UPPERDAR     OP     575 CB   69 KV     CB             .000         .000       
          UPPERDAR     LD     11TR     69 KV                    .000         .000       
12200    L69.Eddystone - Scott Paper                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDDYSTON     L      EDD-SCO  69 KV                    .000         .000       
          SCOTTPAP     OP     585 CB   69 KV     CB             .000         .000       
          EDDYSTON     OP     585 CB   69 KV     CB             .000         .000       
12210    L69.Cedarbrook - Westmoreland                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CEDARBRO     OP     3TRLS CB 13 KV     CB             .000         .000       
          WMORELAN     OP     60 CB    69 KV     CB             .000         .000       
          CEDARBRO     OP     125 CB   69 KV     CB             .000         .000       
          CEDARBRO     L      CED-WMO  69 KV                    .000         .000       
          WMORELAN     OP     20 CB    69 KV     CB             .000         .000       
          CEDARBRO     X      CED 1TR  69 KV                    .000         .000       
          CEDARBRO     OP     1TRLS CB 13 KV     CB             .000         .000       
          CEDARBRO     X      CED 3TR  69 KV                    .000         .000       
12220    L69.Cedarbrook - Whitemarsh                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CEDARBRO     X      CED 2TR  69 KV                    .000         .000       
          CEDARBRO     OP     4TRLS CB 13 KV     CB             .000         .000       
          CEDARBRO     L      CED-WHI  69 KV                    .000         .000       
          CEDARBRO     X      CED 4TR  69 KV                    .000         .000       
          CEDARBRO     OP     215 CB   69 KV     CB             .000         .000       
          CEDARBRO     OP     2TRLS CB 13 KV     CB             .000         .000       
          WHITEMAR     OP     695 CB   69 KV     CB             .000         .000       
12230    L69.Pencoyd - Roxborough                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROXBOROU     X      ROX 4TR  69 KV                    .000         .000       
          PENCOYD      L      PEN-ROX  69 KV                    .000         .000       
          ROXBOROU     OP     125 CB   69 KV     CB             .000         .000       
          PENCOYD      OP     220 CB   69 KV     CB             .000         .000       
          ROXBOROU     OP     4TRLS CB 13 KV     CB             .000         .000       
          PENCOYD      X      3TR      69 KV                    .000         .000       
          PENCOYD      X      1 TR     69 KV                    .000         .000       
12240    L69.Roxborough - Westmoreland                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROXBOROU     L      ROX-WMO  69 KV                    .000         .000       
          ROXBOROU     X      ROX 6TR  69 KV                    .000         .000       
          WMORELAN     OP     30 CB    69 KV     CB             .000         .000       
          ROXBOROU     OP     6TRLS CB 13 KV     CB             .000         .000       
          ROXBOROU     OP     215 CB   69 KV     CB             .000         .000       
          WMORELAN     OP     50 CB    69 KV     CB             .000         .000       
12250    L69.Pencoyd - Westmoreland.6616                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PENCOYD      X      2TR      69 KV                    .000         .000       
          MASTER       L      MAS-WMO5 69 KV                    .000         .000       
          MASTER       OP     165 CB   69 KV     CB             .000         .000       
          PENCOYD      L      PEN-WMO  69 KV                    .000         .000       
          PENCOYD      OP     220 CB   69 KV     CB             .000         .000       
          MASTER       X      MAS 2TR  138 KV                   .000         .000       
          PENCOYD      X      4TR      69 KV                    .000         .000       
12260    L69.Cromby-Limertap-Moser.6680                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MOSER        OP     125 CB   69 KV     CB             .000         .000       
          CROMBY       OP     340 CB   69 KV     CB             .000         .000       
          LIMERTAP     X      LIM 8B   69 KV                    .000         .000       
          LIMERTAP     L      LIM-MOS  69 KV                    .000         .000       
          CROMBY       L      CRO-LIM  69 KV                    .000         .000       
          MOSER        X      MOS 1TR  69 KV                    .000         .000       
          LIMERTAP     X      LIM 8A   69 KV                    .000         .000       
          MOSER        OP     10 CB    35 KV     CB             .000         .000       
          LIMERTAP     OP     805      69 KV     CB             .000         .000       
12270    L69.Cromby-Moser.6681                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MOSER        X      MOS 3TR  69 KV                    .000         .000       
          CROMBY       OP     360 CB   69 KV     CB             .000         .000       
          MOSER        OP     235 CB   69 KV     CB             .000         .000       
          CROMBY       L      CRO-MOS1 69 KV                    .000         .000       
          MOSER        OP     30 CB    35 KV     CB             .000         .000       
12280    L69.Blue Ball - Sunoil                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SUNOIL       U      SUNOIL   13 KV                    .000         .000       
          BLUEBALL     OP     145 CB   69 KV     CB             .000         .000       
          BLUEBALL     OP     455 CB   69 KV     CB             .000         .000       
          BLUEBALL     L      BLU-SUN  69 KV                    .000         .000       
          SUNOIL       OP     82TRHSCB 69 KV     CB             .000         .000       
12290    L69.Goshen - Planebrook                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GOSHEN       L      GOS-PLA  69 KV                    .000         .000       
          GOSHEN       OP     125 CB   69 KV     CB             .000         .000       
          GOSHEN       X      TR 1     69 KV                    .000         .000       
          GOSHEN       LD     BUS1     35 KV                    .000         .000       
          PLANEBRO     X      PLA 9TR  230 KV                   .000         .000       
          PLANEBRO     OP     135      69 KV     CB             .000         .000       
          PLANEBRO     OP     935      69 KV     CB             .000         .000       
          GOSHEN       OP     15 CS    69 KV     CB             .000         .000       
12300    L69.Goshen-NewtownSquare-Middletown.6902          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GOSHEN       LD     BUS2     35 KV                    .000         .000       
          GOSHNTAP     OP     GOSHEN D 69 KV     DIS            .000         .000       
          GOSHEN       OP     235 CB   69 KV     CB             .000         .000       
          GOSHEN       OP     23 DIS   69 KV     DIS            .000         .000       
          GOSHNTAP     L      GOS-MID  69 KV                    .000         .000       
          GOSHEN       OP     25 CS    69 KV     CB             .000         .000       
          NEWTOWNS     OP     TAP DIS  69 KV     DIS            .000         .000       
          MIDD PE      OP     025 CB   69 KV     CB             .000         .000       
          MIDD PE      X      MID 9TR  230 KV                   .000         .000       
          NEWTOWNS     OP     CS  125  69 KV     DIS            .000         .000       
          NEWTOWNS     OP     235      69 KV     CB             .000         .000       
          GOSHEN       L      GOS-GOS  69 KV                    .000         .000       
          GOSHNTAP     L      GOS-NEW  69 KV                    .000         .000       
          NEWTOWNS     OP     223      69 KV     DIS            .000         .000       
          NEWTOWNS     OP     2TRLS    13 KV     CB             .000         .000       
          GOSHNTAP     OP     MIDDLTSF 69 KV     DIS            .000         .000       
          NEWTOWNS     X      2TR      69 KV                    .000         .000       
          GOSHEN       X      TR 2     69 KV                    .000         .000       
12310    138/13.Bluegrass.5TR                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BLUEGRAS     OP     5TRLS CB 13 KV     CB             .000         .000       
          BLUEGRAS     X      BLU 5TR  138 KV                   .000         .000       
          BLUEGRAS     OP     165 CB   138 KV    CB             .000         .000       
          BLUEGRAS     L      BLU-HOL  138 KV                   .000         .000       
          BLUEGRAS     OP     805 CB   138 KV    CB             .000         .000       
12320    230/35.Buckingham.4TR                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BUCKINGH     OP     325 CB   35 KV     CB             .000         .000       
          BUCKINGH     L      BUC-WAR  230 KV                   .000         .000       
          BUCKINGH     OP     195 CB   230 KV    CB             .000         .000       
          BUCKINGH     X      BUCK4TR  230 KV                   .000         .000       
          BUCKINGH     OP     20       35 KV     CB             .000         .000       
          BUCKINGH     OP     40 CB    35 KV     CB             .000         .000       
          BUCKINGH     X      BUCK2TR  230 KV                   .000         .000       
          BUCKINGH     LD     2 TR     35 KV                    .000         .000       
          BUCKINGH     OP     220 CB   230 KV    CB             .000         .000       
12340    35/13.Falls.4TR                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FALLS        OP     3 CT CB  13 KV     CB             .000         .000       
          FALLS        U      UNIT02   13 KV                    .000         .000       
          FALLS        OP     2 CT CB  13 KV     CB             .000         .000       
          FALLS        X      FALL4TR  35 KV                    .000         .000       
          FALLS        OP     40 CB    35 KV     CB             .000         .000       
          FALLS        U      UNIT03   13 KV                    .000         .000       
          FALLS        OP     1 CT CB  13 KV     CB             .000         .000       
          FALLS        U      UNIT01   13 KV                    .000         .000       
12350    138/13.Foxchase.6TR                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FOXCHASE     X      FOX 6TR  138 KV                   .000         .000       
          FOXCHASE     OP     6TRLS CB 13 KV     CB             .000         .000       
          FOXCHASE     OP     985 CB   138 KV    CB             .000         .000       
          FOXCHASE     OP     245 CB   138 KV    CB             .000         .000       
          CRESCENT     L      CRE-FOX  138 KV                   .000         .000       
12360    138/69.Holmesburg.T9                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HOLMESBU     X      HOL13TR  138 KV                   .000         .000       
          HOLMESBU     OP     905 CB   138 KV    CB             .000         .000       
          HOLMESBU     OP     13TRLSCB 13 KV     CB             .000         .000       
          HOLMESBU     OP     065 CB   69 KV     CB             .000         .000       
          HOLMESBU     L      HOL-TAC  69 KV                    .000         .000       
          HOLMESBU     X      HOL 9TR  138 KV                   .000         .000       
12370    69/13.Island Road.2TR+4TR                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ISLANDRD     OP     3TRLS CB 13 KV     CB             .000         .000       
          ISLANDRD     OP     24TRHSCB 69 KV     CB             .000         .000       
          ISLANDRD     OP     2TRLS CB 13 KV     CB             .000         .000       
          ISLANDRD     X      IR 2TR   69 KV                    .000         .000       
          ISLANDRD     X      IR 4TR   69 KV                    .000         .000       
12380    230/13.Jenkintown.2TR+11TR                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JENKINTO     OP     80 CB    35 KV     CB             .000         .000       
          JENKINTO     OP     210 CB   230 KV    CB             .000         .000       
          JENKINTO     OP     230 CB   230 KV    CB             .000         .000       
          JENKINTO     L      JEN-TAB  230 KV                   .000         .000       
          JENKINTO     OP     11TRLSCB 13 KV     CB             .000         .000       
          JENKINTO     X      JENK 2T  230 KV                   .000         .000       
          JENKINTO     X      JENK11T  230 KV                   .000         .000       
12390    230/13.Mac Dade.2TR                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MACDADE      OP     25 CS    230 KV    DIS            .000         .000       
          MACDADE      OP     805 CB   230 KV    CB             .000         .000       
          MACDADE      X      MCDADE2  230 KV                   .000         .000       
12400    69/35.Moser.2TR                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MOSER        OP     125 CB   69 KV     CB             .000         .000       
          MOSER        OP     70 CB    35 KV     CB             .000         .000       
          MOSER        OP     50 CB    35 KV     CB             .000         .000       
          MOSER        X      MOS 2TR  69 KV                    .000         .000       
          MOSER        OP     235 CB   69 KV     CB             .000         .000       
12410    35/13.Moser.4TR                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MOSER        U      UNIT2    13 KV                    .000         .000       
          MOSER        OP     3 CT CB  13 KV     CB             .000         .000       
          MOSER        OP     40 CB    35 KV     CB             .000         .000       
          MOSER        OP     1 CT CB  13 KV     CB             .000         .000       
          MOSER        OP     2 CT CB  13 KV     CB             .000         .000       
          MOSER        X      MOS 4TR  35 KV                    .000         .000       
          MOSER        U      UNIT3    13 KV                    .000         .000       
          MOSER        U      UNIT1    13 KV                    .000         .000       
12430    69/13.Passyunk.3TR+6TR                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PASSYUNK     X      PAS 6TR  69 KV                    .000         .000       
          PASSYUNK     OP     3TRLS CB 13 KV     CB             .000         .000       
          PASSYUNK     OP     6TRLS CB 13 KV     CB             .000         .000       
          PASSYUNK     OP     435 CB   69 KV     CB             .000         .000       
          PASSYUNK     OP     325 CB   69 KV     CB             .000         .000       
          PASSYUNK     X      PAS 3TR  69 KV                    .000         .000       
12440    230/35.Planebrook.T2                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PLANEBRO     X      PLA 2TR  230 KV                   .000         .000       
          PLANEBRO     OP     785 CB   230 KV    CB             .000         .000       
          PLANEBRO     OP     20 CB    35 KV     CB             .000         .000       
          PLANEBRO     OP     885      230 KV    CB             .000         .000       
          PLANEBRO     OP     985 CB   230 KV    CB             .000         .000       
          PLANEBRO     X      PLA 8TR  230 KV                   .000         .000       
          PLANEBRO     OP     805      230 KV    CB             .000         .000       
12450    230/69.Planebrook.T9 + 230/35.Planebrook.T3       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PLANEBRO     OP     985 CB   230 KV    CB             .000         .000       
          PLANEBRO     OP     935      69 KV     CB             .000         .000       
          PLANEBRO     X      PLA 9TR  230 KV                   .000         .000       
          PLANEBRO     X      PLA 3TR  230 KV                   .000         .000       
          PLANEBRO     OP     095      230 KV    CB             .000         .000       
          PLANEBRO     OP     315 CB   230 KV    CB             .000         .000       
          PLANEBRO     OP     30 CB    35 KV     CB             .000         .000       
          BRADFORD     L      BRA-PLA1 230 KV                   .000         .000       
          PLANEBRO     L      PLA-TRE9 230 KV                   .000         .000       
12460    230/69.Schuylkill.7TR                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GRAYSFER     L      GRA-SCH7 230 KV                   .000         .000       
          SCHUYLKI     X      SCH 7TR  230 KV                   .000         .000       
          SCHUYLKI     OP     140 CB   69 KV     CB             .000         .000       
          GRAYSFER     OP     775 CB   230 KV    CB             .000         .000       
          SCHUYLKI     OP     150 CB   69 KV     CB             .000         .000       
12470    230/69.Schuylkill.8TR                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SCHUYLKI     OP     360 CB   69 KV     CB             .000         .000       
          SCHUYLKI     OP     240 CB   69 KV     CB             .000         .000       
          GRAYSFER     L      GRA-SCH8 230 KV                   .000         .000       
          SCHUYLKI     X      SCH 8TR  230 KV                   .000         .000       
          GRAYSFER     OP     985 CB   230 KV    CB             .000         .000       
          SCHUYLKI     OP     350 CB   69 KV     CB             .000         .000       
          SCHUYLKI     OP     230 CB   69 KV     CB             .000         .000       
12480    Tacony 1TR 69/13 kV Transformer                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TACONY       OP     1TRLS CB 13 KV     CB             .000         .000       
          TACONY       OP     65 CB    69 KV     CB             .000         .000       
          HOLMESBU     L      HOL-TAC  69 KV                    .000         .000       
          TACONY       OP     215 CB   69 KV     CB             .000         .000       
          TACONY       X      TAC 1TR  69 KV                    .000         .000       
12490    Tacony 2TR 69/13 kV Transformer                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TACONY       OP     215 CB   69 KV     CB             .000         .000       
          RICH PE      L      RIC-TAC  69 KV                    .000         .000       
          TACONY       X      TAC 2TR  69 KV                    .000         .000       
          TACONY       OP     2TRLS CB 13 KV     CB             .000         .000       
          TACONY       OP     55 CB    69 KV     CB             .000         .000       
12500    Upper Darby 6TR 69/35 kV Transformer              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          UPPERDAR     OP     65 CB    69 KV     CB             .000         .000       
          UPPERDAR     OP     3-4 CB   35 KV     CB             .000         .000       
          UPPERDAR     CP     1-2 CAP  35 KV                    .000         .000       
          UPPERDAR     CP     3-4 CAP  35 KV                    .000         .000       
          UPPERDAR     X      UPD 6TR  69 KV                    .000         .000       
          UPPERDAR     OP     1-2 CB   35 KV     CB             .000         .000       
12510    Whitemarsh 7TR 230/69 kV Transformer              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CEDARBRO     L      CED-WHI  69 KV                    .000         .000       
          WHITEMAR     OP     20 CB    35 KV     CB             .000         .000       
          WHITEMAR     X      WHIT7TR  230 KV                   .000         .000       
          WHITEMAR     X      WHIT8TR  69 KV                    .000         .000       
          WHITEMAR     OP     185 CB   69 KV     CB             .000         .000       
          WHITEMAR     OP     75 CB    230 KV    CB             .000         .000       
          WHITEMAR     OP     695 CB   69 KV     CB             .000         .000       
12520    Heaton 2TR/3TR 138/35 kV Transformer              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HEATON       OP     995 CB   138 KV    CB             .000         .000       
          HEATON       X      HEA 3TR  138 KV                   .000         .000       
          HEATON       OP     150 CB   138 KV    CB             .000         .000       
          HEATON       X      HEA 9TR  230 KV                   .000         .000       
          HEATON       X      HEA 2TR  138 KV                   .000         .000       
          HEATON       OP     80 CB    35 KV     CB             .000         .000       
          HEATON       OP     3TRLS    13 KV     CB             .000         .000       
12580    Chichester 3TR 230/13 kV Transformer (Load1)      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHICHEST     LD     DBU1     230 KV                   .000         .000       
          CHICHEST     OP     135 CB   230 KV    CB             .000         .000       
12590    Chichester 5TR 230/13 kV Transformer (Load2)      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHICHEST     OP     255 CB   230 KV    CB             .000         .000       
          CHICHEST     LD     DBU2     230 KV                   .000         .000       
12620    Wayne Jct 1 230/13 kV Transformer (LoadDBU1)      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WAYNEJCT     OP     2A CB    230 KV    CB             .000         .000      P
          WAYNEJCT     OP     2T DIS   230 KV    CB             .000         .000      P
          WAYNEJCT     LD     DBU1     230 KV                   .000         .000      P
12630    Wayne Jct 2 230/13 kV Transformer (LoadDBU2)      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WAYNEJCT     LD     DBU2     230 KV                   .000         .000       
          WAYNEJCT     OP     1A CB    230 KV    CB             .000         .000       
          WAYNEJCT     OP     1T DIS   230 KV    CB             .000         .000       
12640    Buckingham 230 kV capacitor                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BUCKINGH     OP     115 CB   230 KV    CB             .000         .000       
          BUCKINGH     CP     BUCK 1-1 230 KV                   .000         .000       
12650    North Wales 230 kV capacitor                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NWALES       CP     CAP 10-1 230 KV                   .000         .000       
          NWALES       OP     105      230 KV    CB             .000         .000       
12660    Woodbourne 230 kV capacitor                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WOODBOUR     OP     105 CB   230 KV    CB             .000         .000       
          WOODBOUR     CP     WOODBOU  230 KV                   .000         .000       
12670    Conowingo.U1                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONOWING     U      GEN1     13 KV                    .000         .000       
          CONOWING     OP     1 GEN CB 13 KV     CB             .000         .000       
12680    Conowingo.U2                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONOWING     OP     2 GEN CB 13 KV     CB             .000         .000       
          CONOWING     U      GEN2     13 KV                    .000         .000       
12690    Conowingo.U3                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONOWING     U      GEN3     13 KV                    .000         .000       
          CONOWING     OP     3 GEN CB 13 KV     CB             .000         .000       
12700    Conowingo.U4                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONOWING     OP     4 GEN CB 13 KV     CB             .000         .000       
          CONOWING     U      GEN4     13 KV                    .000         .000       
12710    Conowingo.U5                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONOWING     OP     5 GEN CB 13 KV     CB             .000         .000       
          CONOWING     U      GEN5     13 KV                    .000         .000       
12720    Conowingo.U6                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONOWING     OP     6 GEN CB 13 KV     CB             .000         .000       
          CONOWING     U      GEN6     13 KV                    .000         .000       
12730    Conowingo.U7                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONOWING     X      CONO4TR  230 KV                   .000         .000       
          CONOWING     U      UNIT07   13 KV                    .000         .000       
          CONOWING     OP     7 GEN CB 13 KV     CB             .000         .000       
12740    Conowingo.U8                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONOWING     U      GEN8     13 KV                    .000         .000       
          CONOWING     OP     8 GEN CB 13 KV     CB             .000         .000       
12750    Conowingo.U9                                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONOWING     U      GEN9     13 KV                    .000         .000       
          CONOWING     OP     9 GEN CB 13 KV     CB             .000         .000       
12760    Conowingo.U10                                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONOWING     U      G10      13 KV                    .000         .000       
          CONOWING     OP     10GEN CB 13 KV     CB             .000         .000       
12770    Conowingo.U11                                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONOWING     U      G11      13 KV                    .000         .000      P
          CONOWING     OP     11GEN CB 13 KV     CB             .000         .000      P
12780    Croydon #11 CT                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROYDON      U      UNIT11   13 KV                    .000         .000       
          CROYDON      OP     11 CT CB 13 KV     CB             .000         .000       
12790    Croydon #12 CT                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROYDON      U      UNIT12   13 KV                    .000         .000      P
          CROYDON      OP     12 CT CB 13 KV     CB             .000         .000      P
12800    Croydon #21 CT                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROYDON      U      UNIT21   13 KV                    .000         .000      P
          CROYDON      OP     21 CT CB 13 KV     CB             .000         .000      P
12810    Croydon #22 CT                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROYDON      U      UNIT22   13 KV                    .000         .000      P
          CROYDON      OP     22 CT CB 13 KV     CB             .000         .000      P
12820    Croydon #31 CT                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROYDON      OP     31 CT CB 13 KV     CB             .000         .000      P
          CROYDON      U      UNIT31   13 KV                    .000         .000      P
12830    Croydon #32 CT                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROYDON      U      UNIT32   13 KV                    .000         .000      P
          CROYDON      OP     32 CT CB 13 KV     CB             .000         .000      P
12840    Croydon #41 CT                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROYDON      OP     41 CT CB 13 KV     CB             .000         .000      P
          CROYDON      U      UNIT41   13 KV                    .000         .000      P
12850    Croydon #42 CT                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROYDON      OP     42 CT CB 13 KV     CB             .000         .000      P
          CROYDON      U      UNIT42   13 KV                    .000         .000      P
12860    Delaware #9 CT                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DELA PE      OP     9 CT CB  13 KV     CB             .000         .000      P
          DELA PE      U      UNIT09   13 KV                    .000         .000      P
12870    Delaware #10 CT                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DELA PE      U      UNIT10   13 KV                    .000         .000      P
          DELA PE      OP     10 CT CB 13 KV     CB             .000         .000      P
12880    Delaware #11 CT                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DELA PE      U      UNIT11   13 KV                    .000         .000      P
          DELA PE      OP     11 CT CB 13 KV     CB             .000         .000      P
12890    Delaware #12 CT                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DELA PE      U      UNIT12   13 KV                    .000         .000      P
          DELA PE      OP     12 CT CB 13 KV     CB             .000         .000      P
12900    Eddystone #30 CT                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDDYSTON     OP     30 CT CB 13 KV     CB             .000         .000      P
          EDDYSTON     U      UNIT30   13 KV                    .000         .000      P
12910    Eddystone #40 CT                                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDDYSTON     OP     40 CT CB 13 KV     CB             .000         .000      P
          EDDYSTON     U      UNIT40   13 KV                    .000         .000      P
12920    Falls #1 CT                                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FALLS        U      UNIT01   13 KV                    .000         .000      P
          FALLS        OP     1 CT CB  13 KV     CB             .000         .000      P
12930    Falls #2 CT                                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FALLS        U      UNIT02   13 KV                    .000         .000      P
          FALLS        OP     2 CT CB  13 KV     CB             .000         .000      P
12940    Falls #3 CT                                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FALLS        OP     3 CT CB  13 KV     CB             .000         .000       
          FALLS        U      UNIT03   13 KV                    .000         .000       
12950    Farhills A Gen Unit                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FARHILLS     OP     A GEN CB 13 KV     CB             .000         .000       
          FARHILLS     U      A GEN    13 KV                    .000         .000       
12960    Farhills B Gen Unit                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FARHILLS     U      B GEN    13 KV                    .000         .000       
          FARHILLS     OP     B GEN CB 13 KV     CB             .000         .000       
12970    Merck COGEN Nug                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MERCK        U      COGEN    13 KV                    .000         .000      P
          MERCK        OP     TG3-13   13 KV     CB             .000         .000      P
12980    Moser #1 CT                                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MOSER        OP     1 CT CB  13 KV     CB             .000         .000      P
          MOSER        U      UNIT1    13 KV                    .000         .000      P
12990    Moser #2 CT                                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MOSER        OP     2 CT CB  13 KV     CB             .000         .000      P
          MOSER        U      UNIT2    13 KV                    .000         .000      P
13000    Moser #3 CT                                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MOSER        U      UNIT3    13 KV                    .000         .000      P
          MOSER        OP     3 CT CB  13 KV     CB             .000         .000      P
13010    Muddy Run 1 Gen Unit                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MUDDYRN      OP     1 GEN CB 13 KV     CB             .000         .000       
          MUDDYRN      U      UNIT1    13 KV                    .000         .000       
13020    Muddy Run 2 Gen Unit                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MUDDYRN      OP     2 GEN CB 13 KV     CB             .000         .000      P
          MUDDYRN      U      UNIT2    13 KV                    .000         .000      P
13030    Muddy Run 3 Gen Unit                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MUDDYRN      OP     3 GEN CB 13 KV     CB             .000         .000      P
          MUDDYRN      U      UNIT3    13 KV                    .000         .000      P
13040    Muddy Run 4 Gen Unit                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MUDDYRN      OP     4 GEN CB 13 KV     CB             .000         .000      P
          MUDDYRN      U      UNIT4    13 KV                    .000         .000      P
13050    Muddy Run 5 Gen Unit                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MUDDYRN      U      UNIT5    13 KV                    .000         .000       
          MUDDYRN      OP     5 GEN CB 13 KV     CB             .000         .000       
13060    Muddy Run 6 Gen Unit                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MUDDYRN      U      UNIT6    13 KV                    .000         .000      P
          MUDDYRN      OP     6 GEN CB 13 KV     CB             .000         .000      P
13070    Muddy Run 7 Gen Unit                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MUDDYRN      U      UNIT7    13 KV                    .000         .000      P
          MUDDYRN      OP     7 GEN CB 13 KV     CB             .000         .000      P
13080    Muddy Run 8 Gen Unit                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MUDDYRN      OP     8 GEN CB 13 KV     CB             .000         .000      P
          MUDDYRN      U      UNIT8    13 KV                    .000         .000      P
13090    Richmond #91 CT                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RICH PE      OP     91 CT CB 13 KV     CB             .000         .000       
          RICH PE      U      UNIT91   13 KV                    .000         .000       
13100    Richmond #92 CT                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RICH PE      U      UNIT92   13 KV                    .000         .000      P
          RICH PE      OP     92 CT CB 13 KV     CB             .000         .000      P
13120    Schuylkill #10 CT                                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SCHUYLKI     OP     10 CT CB 13 KV     CB             .000         .000      P
          SCHUYLKI     U      UNIT10   13 KV                    .000         .000      P
13130    Schuylkill #11 CT                                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SCHUYLKI     OP     11 CT CB 13 KV     CB             .000         .000      P
          SCHUYLKI     U      UNIT11   13 KV                    .000         .000      P
13140    Southwark #3 CT                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SWARK        U      UNIT3    13 KV                    .000         .000      P
          SWARK        OP     3 CT CB  13 KV     CB             .000         .000      P
13150    Southwark #4 CT                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SWARK        U      UNIT4    13 KV                    .000         .000       
          SWARK        OP     4 CT CB  13 KV     CB             .000         .000       
13160    Southwark #5 CT                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SWARK        U      UNIT5    13 KV                    .000         .000      P
          SWARK        OP     5 CT CB  13 KV     CB             .000         .000      P
13170    Southwark #6 CT                                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SWARK        U      UNIT6    13 KV                    .000         .000      P
          SWARK        OP     6 CT CB  13 KV     CB             .000         .000      P
13180    Passyunk-Schuylkill 6631 (radial fr Schuylkill)   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PASSYUNK     OP     5TRLS CB 13 KV     CB             .000         .000      P
          PASSYUNK     OP     235 CB   69 KV     CB             .000         .000      P
          PASSYUNK     OP     2TRLS CB 13 KV     CB             .000         .000      P
          PASSYUNK     X      PAS 2TR  69 KV                    .000         .000      P
          PASSYUNK     X      PAS 5TR  69 KV                    .000         .000      P
13190    L138.Weirton-AepTP-WylieRidge + 138/69.SToronto.T1Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STORONT2     OP     A        69 KV     CB             .000         .000      P
          AEPTAP       OP     S212-66  138 KV    DIS            .000         .000      P
          WYLIERID     OP     W9       138 KV    CB             .000         .000      P
          STORONT2     X      1        138 KV                   .000         .000      P
          AEPTAP       L      AEP-WEI  138 KV                   .000         .000      P
          AEPTAP       OP     DUMWYL   138 KV    DIS            .000         .000      P
          AEPTAP       OP     DUMSTO   138 KV    DIS            .000         .000      P
          AEPTAP       L      AEP-STO  138 KV                   .000         .000      P
          WEIRTON      OP     APTAP    138 KV    CB             .000         .000      P
          AEPTAP       L      AEP-WYL  138 KV                   .000         .000      P
          WYLIERID     OP     W8       138 KV    CB             .000         .000      P
13200    L138.Airco-Arroyo-WylieRidge (APS)                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WYLIERID     OP     W5       138 KV    CB             .000         .000      P
          ARROYO       OP     BUSTIE   138 KV    CB             .000         .000      P
          ARROYO       LD     T1       138 KV                   .000         .000      P
          ARROYO       OP     AIRCO    138 KV    DIS            .000         .000      P
          AIRCO        OP     ARROYOCB 138 KV    CB             .000         .000      P
          ARROYO       L      AIR-ARR  138 KV                   .000         .000      P
          ARROYO       OP     WYLIERID 138 KV    DIS            .000         .000      P
          ARROYO       L      ARR-WYL  138 KV                   .000         .000      P
          AIRCO        LD     T1       138 KV                   .000         .000      P
          AIRCO        LD     T2       138 KV                   .000         .000      P
          WYLIERID     OP     W6       138 KV    CB             .000         .000      P
13210    ALBRIGHT-BRANDONV-NECESSITY-TEXAS-BETHELBO (APS)  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ALBRIGHT     OP     BRANDONV 138 KV    CB             .000         .000      P
          TEXASEA5     LD     T1       138 KV                   .000         .000      P
          ALBRIGHT     L      ALB-BRA  138 KV                   .000         .000      P
          NUNION       LD     T61      138 KV                   .000         .000      P
          NUNION       OP     T61 DIS  138 KV    DIS            .000         .000      P
          NUTAP1       L      BET-NUT  138 KV                   .000         .000      P
          TEXASEA5     OP     DUMNU    138 KV    DIS            .000         .000      P
          NUTAP1       OP     DUMTEX   138 KV    DIS            .000         .000      P
          BRANDONV     OP     ALBRIGHT 138 KV    DIS            .000         .000      P
          NECESSIT     L      NEC-TEX  138 KV                   .000         .000      P
          TEXASEA5     OP     T1 DIS   138 KV    DIS            .000         .000      P
          BRANDONV     OP     T1 DIS   138 KV    DIS            .000         .000      P
          NUTAP1       L      NUN-NUT  138 KV                   .000         .000      P
          TEXASEA5     OP     NECESSIT 138 KV    DIS            .000         .000      P
          BETHELBO     OP     NU TP1   138 KV    CB             .000         .000      P
          NECESSIT     OP     BB       138 KV    DIS            .000         .000      P
          NUTAP1       OP     DUMNOR   138 KV    DIS            .000         .000      P
          TEXASEA5     L      NUT-TEX  138 KV                   .000         .000      P
          NECESSIT     LD     T1       138 KV                   .000         .000      P
          BRANDONV     LD     T1       138 KV                   .000         .000      P
          NUTAP1       OP     DUMBET   138 KV    DIS            .000         .000      P
          NECESSIT     OP     T1 DIS   138 KV    DIS            .000         .000      P
13220    ALBRIGHT-BRANDJCT-HAZELTON-LAKELYNN (APS)         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRANDJCT     OP     DUM ALBR 138 KV    DIS            .000         .000      P
          ALBRIGHT     OP     BRANDJCT 138 KV    CB             .000         .000      P
          BRANDJCT     L      BRA-LAK  138 KV                   .000         .000      P
          BRANDJCT     OP     DUM LAKE 138 KV    DIS            .000         .000      P
          BRANDJCT     L      BRA-HAZ  138 KV                   .000         .000      P
          ALBRIGHT     L      ALB-BRJ  138 KV                   .000         .000      P
          BRANDJCT     OP     HAZELTON 138 KV    DIS            .000         .000      P
          LAKELYNN     OP     BRANDJCT 138 KV    CB             .000         .000      P
          HAZELTON     OP     BRANDJCT 138 KV    DIS            .000         .000      P
13230    L138.Albright-Denver-Intcoal-Grafton              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DENVER       LD     T1       138 KV                   .000         .000       
          ALBRIGHT     L      ALB-DEN  138 KV                   .000         .000       
          INTCOAL      OP     DUMLD    138 KV    DIS            .000         .000       
          GRAFTON      OP     B22      138 KV    CB             .000         .000       
          DENVER       OP     A1244    138 KV    DIS            .000         .000       
          DENVER       OP     432J     138 KV    DIS            .000         .000       
          DENVER       OP     A1245    138 KV    DIS            .000         .000       
          INTCOAL      OP     1070     138 KV    DIS            .000         .000       
          DENVER       L      DEN-INT  138 KV                   .000         .000       
          ALBRIGHT     OP     DENVER   138 KV    CB             .000         .000       
          GRAFTON      L      GRA-INT  138 KV                   .000         .000       
          DENVER       OP     433J     138 KV    DIS            .000         .000       
          INTCOAL      OP     1069     138 KV    DIS            .000         .000       
          INTCOAL      LD     LOAD1    138 KV                   .000         .000       
          DENVER       OP     1221     138 KV    DIS            .000         .000       
          DENVER       LD     T2       138 KV                   .000         .000       
13240    ALBRIGHT-KINGWOOD-PRUNTYTOWN (APS)                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KINGWOOD     OP     PRUNTYTO 138 KV    DIS            .000         .000      P
          ALBRIGHT     OP     KINGWOOD 138 KV    CB             .000         .000      P
          PRUNTYTO     OP     P13      138 KV    CB             .000         .000      P
          KINGWOOD     LD     T2       138 KV                   .000         .000      P
          KINGWOOD     L      KIN-PRU  138 KV                   .000         .000      P
          KINGWOOD     OP     BUS TIE  138 KV    DIS            .000         .000      P
          PRUNTYTO     OP     P14      138 KV    CB             .000         .000      P
          KINGWOOD     OP     ALBRIGHT 138 KV    DIS            .000         .000      P
          KINGWOOD     LD     T1       138 KV                   .000         .000      P
          KINGWOOD     OP     T1 DIS   138 KV    DIS            .000         .000      P
          KINGWOOD     L      ALB-KIN  138 KV                   .000         .000      P
          KINGWOOD     OP     T2 DIS   138 KV    DIS            .000         .000      P
13250    L138.Albright-Ruthbelle-CheatLake                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RUTHBELL     OP     T1 DIS   138 KV    DIS            .000         .000      P
          CHTLAKE      L      CHT-RUT  138 KV                   .000         .000      P
          RUTHBELL     OP     ALBRIGHT 138 KV    DIS            .000         .000      P
          RUTHBELL     LD     T1       138 KV                   .000         .000      P
          CHTLAKE      OP     BUSTIE   138 KV    CB             .000         .000      P
          ALBRIGHT     L      ALB-RUT  138 KV                   .000         .000      P
          RUTHBELL     OP     BUSTIE   138 KV    DIS            .000         .000      P
          ALBRIGHT     OP     RUTHBELL 138 KV    CB             .000         .000      P
13260    L138.LakeLyn-CheatLake                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LAKELYNN     OP     CHEATLAK 138 KV    CB             .000         .000       
          CHTLAKE      OP     T62 DIS  138 KV    DIS            .000         .000       
          CHTLAKE      L      CHT-LAK  138 KV                   .000         .000       
          CHTLAKE      OP     T4 DIS   138 KV    DIS            .000         .000       
          CHTLAKE      X      4        138 KV                   .000         .000       
          CHTLAKE      OP     BUSTIE   138 KV    CB             .000         .000       
13270    ALBRIGHT-SNOWYCREEK-OAKPARK-KELSO GAP 138 KV(APS) Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OAKPARK      OP     T2 DIS   138 KV    DIS            .000         .000       
          SNOWYTAP     OP     DUM2     138 KV    DIS            .000         .000       
          OAKPARK      OP     SNOWYCRE 138 KV    DIS            .000         .000       
          OAKPARK      LD     T2       138 KV                   .000         .000       
          SNOWYTAP     OP     1300     138 KV    DIS            .000         .000       
          OAKPARK      OP     T1 DIS   138 KV    DIS            .000         .000       
          OAKPARK      OP     BUSTIE   138 KV    DIS            .000         .000       
          OAKPARK      LD     T1       138 KV                   .000         .000       
          SNOWYTAP     OP     DUM1     138 KV    DIS            .000         .000       
          KELSOGAP     OP     3 CB     138 KV    CB             .000         .000       
          KELSOGAP     OP     1 CB     138 KV    CB             .000         .000       
          ALBRIGHT     OP     SNOWYCRE 138 KV    CB             .000         .000       
          SNOWYCRE     X      1        138 KV                   .000         .000       
          SNOWYCRE     OP     T1 DIS   138 KV    DIS            .000         .000       
          KELSOGAP     L      KEL-OAK  138 KV                   .000         .000       
          OAKPARK      OP     KELSOGAP 138 KV    DIS            .000         .000       
          ALBRIGHT     L      ALB-SNO  138 KV                   .000         .000       
          KELSOGAP     OP     DUMOAK   138 KV    DIS            .000         .000       
13280    ALBRIGHT-GARRETT-GARRETT TAP-CARLOS JCT (APS)     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ALBRIGHT     OP     GARRETT  138 KV    CB             .000         .000      P
          GARRETT      OP     CARLOJCT 138 KV    CB             .000         .000      P
          GARRETT      OP     T4 DIS   138 KV    DIS            .000         .000      P
          GARRETT      LD     T4       138 KV                   .000         .000      P
          GARRETT      X      TRAN  2  138 KV                   .000         .000      P
          GARRETT      OP     T2 CB    138 KV    CB             .000         .000      P
          GARRETT      OP     T1 DIS   138 KV    DIS            .000         .000      P
          GARRETT      L      CAR-GAR  138 KV                   .000         .000      P
          ALBRIGHT     L      ALB-GAR  138 KV                   .000         .000      P
          GARRETT      OP     ALBRIGHT 138 KV    DIS            .000         .000      P
          GARRETT      LD     T1       138 KV                   .000         .000      P
          GARRETT      L      GAR-GAR  115 KV                   .000         .000      P
13290    L138.Albright-Mettiki-Rothrock-William            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROTHROCK     U      ROTHRKWF 34.5 KV                  .000         .000      P
          WILLIAM      OP     METTIKI  138 KV    CB             .000         .000      P
          METTIKI      OP     1297     138 KV    DIS            .000         .000      P
          WILLIAM      L      MET-WIL  138 KV                   .000         .000      P
          METTIKI      OP     MET DIS  138 KV    DIS            .000         .000      P
          METTIKI      LD     METTIKI  138 KV                   .000         .000      P
          ROTHROCK     OP     GEN      138 KV    CB             .000         .000      P
          ALBRIGHT     L      ALB-MET  138 KV                   .000         .000      P
          ALBRIGHT     OP     METTIKI  138 KV    CB             .000         .000      P
          METTIKI      OP     1296     138 KV    DIS            .000         .000      P
          ROTHROCK     L      ROT-MET  138 KV                   .000         .000      P
13300    WILLIAM BACKBONE UNIT (APS)                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WILLIAM      U      BACKBONE 34 KV                    .000         .000       
13310    ALBRIGHT-MTZION-WESTVACO-CROSSSCHOOL 138kV (APS)  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ALBRIGHT     OP     MTZION   138 KV    CB             .000         .000      P
          MTZI APS     LD     T1       138 KV                   .000         .000      P
          WESTVACO     LD     T1       138 KV                   .000         .000      P
          BERYL        OP     1306     138 KV    DIS            .000         .000      P
          WESTVACO     OP     BUS TIE  138 KV    DIS            .000         .000      P
          CROSSSCH     OP     CS2      138 KV    CB             .000         .000      P
          WESTVACO     OP     T2 DIS   138 KV    DIS            .000         .000      P
          CROSSSCH     L      BER-CRS  138 KV                   .000         .000      P
          ALBRIGHT     L      ALB-MTZ  138 KV                   .000         .000      P
          BERYL        OP     1391     138 KV    DIS            .000         .000      P
          WESTVACO     LD     T2       138 KV                   .000         .000      P
          WESTVACO     L      BER-WES  138 KV                   .000         .000      P
          WESTVACO     OP     DUM3     138 KV    DIS            .000         .000      P
          MTZI APS     OP     ALBRIGHT 138 KV    DIS            .000         .000      P
          CROSSSCH     OP     CS1      138 KV    CB             .000         .000      P
          WESTVACO     OP     T1 DIS   138 KV    DIS            .000         .000      P
          MTZI APS     OP     WESTVACO 138 KV    DIS            .000         .000      P
          BERYL        L      BER-MTZ  138 KV                   .000         .000      P
          BERYL        OP     1305     138 KV    DIS            .000         .000      P
          MTZI APS     OP     T1 DIS   138 KV    DIS            .000         .000      P
13350    RIVESVILLE-SANFORD-ALCAN-STONYRD-PRUNTYTOWN (APS) Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SANFORD      LD     T1       138 KV                   .000         .000      P
          RIVESVIL     OP     SANFORD  138 KV    CB             .000         .000      P
          SANFORD      L      ALC-SAN  138 KV                   .000         .000      P
          SANFORD      L      RIV-SAN  138 KV                   .000         .000      P
          STONYRD      L      PRU-STO  138 KV                   .000         .000      P
          PRUNTYTO     OP     P7       138 KV    CB             .000         .000      P
          STONYRD      OP     BUSTIE   138 KV    DIS            .000         .000      P
          STONYRD      OP     T3 DIS   138 KV    DIS            .000         .000      P
          SANFORD      OP     T1 DIS   138 KV    DIS            .000         .000      P
          ALCAN        OP     DUM STO  138 KV    DIS            .000         .000      P
          ALCAN        LD     ALCAN    138 KV                   .000         .000      P
          STONYRD      OP     PRUNTYTO 138 KV    DIS            .000         .000      P
          SANFORD      OP     DUMRIV   138 KV    DIS            .000         .000      P
          STONYRD      L      ALC-STO  138 KV                   .000         .000      P
          STONYRD      LD     T2       138 KV                   .000         .000      P
          ALCAN        OP     DUM SAN  138 KV    DIS            .000         .000      P
          STONYRD      LD     T3       138 KV                   .000         .000      P
          ALCAN        OP     ALC CB   138 KV    CB             .000         .000      P
          STONYRD      OP     T2 DIS   138 KV    DIS            .000         .000      P
          PRUNTYTO     OP     P8       138 KV    CB             .000         .000      P
          STONYRD      LD     T1       138 KV                   .000         .000      P
          STONYRD      OP     T1 DIS   138 KV    DIS            .000         .000      P
          STONYRD      OP     ALCAN    138 KV    DIS            .000         .000      P
          SANFORD      OP     ALCAN    138 KV    DIS            .000         .000      P
13360    ALLDAM6  GEN  6   (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ALLDAM6      U      GEN  6   138 KV                   .000         .000       
          ALLDAM6      OP     DUM6     138 KV    DIS            .000         .000       
13370    L138.Kittanning-AllDam6                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KITTANNI     OP     ALLDAM6  138 KV    CB             .000         .000      P
          ALLDAM6      L      ALL-KIT  138 KV                   .000         .000      P
          ALLDAM6      U      GEN  6   138 KV                   .000         .000      P
          ALLDAM6      OP     ALUD4JCT 138 KV    CB             .000         .000      P
          ALLDAM6      U      GEN  5   138 KV                   .000         .000      P
          ALLDAM6      OP     KITTANNI 138 KV    DIS            .000         .000      P
          ALLDAM6      OP     DUM5     138 KV    DIS            .000         .000      P
          ALLDAM6      OP     DUM6     138 KV    DIS            .000         .000      P
13380    L138.KiskiValley-BrackenRidge-ShaffersCorner      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRACKNJC     OP     DUMKVAL  138 KV    DIS            .000         .000      P
          SHAFFERS     OP     BRDGJCT  138 KV    DIS            .000         .000      P
          BRACKNJC     L      BRAJ-KIS 138 KV                   .000         .000      P
          SHAFFERS     OP     BUS TIE  138 KV    DIS            .000         .000      P
          SHAFFERS     OP     T61 DIS  138 KV    DIS            .000         .000      P
          BRACKNJC     OP     DUMBRDG  138 KV    DIS            .000         .000      P
          BRACKNJC     L      BRAJ-SHA 138 KV                   .000         .000      P
          BRACKNJC     OP     DUMSCOR  138 KV    DIS            .000         .000      P
          SHAFFERS     LD     T61      138 KV                   .000         .000      P
          BRACKNJC     L      BRA-BRAJ 138 KV                   .000         .000      P
          KISKIVAL     OP     BRDGJCT  138 KV    CB             .000         .000      P
          BRACKENR     OP     BRDGJCT  138 KV    CB             .000         .000      P
13390    ALLENPOR-CHARLEROI (APS)                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHARLERO     OP     ALLENPOR 138 KV    CB             .000         .000      P
          ALLENPOR     L      ALL-CHA  138 KV                   .000         .000      P
          ALLENPOR     OP     CHARLERO 138 KV    CB             .000         .000      P
13400    ALLENPOR-FRAZIER-LAYTOJCT-SMITHTON-YUKON-IRONBRID Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LAYTOJCT     OP     DUMSMI   138 KV    DIS            .000         .000       
          LAYTOJCT     OP     DUMIRO   138 KV    DIS            .000         .000       
          LAYTOJCT     L      LAY-SMI  138 KV                   .000         .000       
          YUKON        OP     SMITHTO1 138 KV    DIS            .000         .000       
          SMITHTON     OP     T61 DIS  138 KV    DIS            .000         .000       
          LAYTOJCT     L      IRO-LAY  138 KV                   .000         .000       
          LAYTOJCT     L      FRA-LAY  138 KV                   .000         .000       
          FRAZIER      OP     ALLENPOR 138 KV    DIS            .000         .000       
          FRAZIER      OP     LAYTOJCT 138 KV    DIS            .000         .000       
          FRAZIER      OP     BUS TIE  138 KV    DIS            .000         .000       
          SMITHTON     OP     YUK1LAYT 138 KV    DIS            .000         .000       
          ALLENPOR     L      ALL-FRA  138 KV                   .000         .000       
          SMITHTON     LD     T61      138 KV                   .000         .000       
          YUKON        OP     Y3       138 KV    CB             .000         .000       
          YUKON        OP     Y5       138 KV    CB             .000         .000       
          IRONBRID     OP     LAYTOJCT 138 KV    CB             .000         .000       
          YUKON        L      SMI-YUK  138 KV                   .000         .000       
          FRAZIER      OP     T62 DIS  138 KV    DIS            .000         .000       
          ALLENPOR     OP     FRAZIER  138 KV    CB             .000         .000       
          FRAZIER      LD     T62      138 KV                   .000         .000       
          LAYTOJCT     OP     DUMFRA   138 KV    DIS            .000         .000       
13410    EHAGERSTOWN-ANTIETAM-REID (APS)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ANTIETAM     OP     T2 DIS   138 KV    DIS            .000         .000      P
          ANTIETAM     OP     EHAGERST 138 KV    DIS            .000         .000      P
          ANTIETAM     L      ANT-REI2 138 KV                   .000         .000      P
          ANTIETAM     OP     T1 DIS   138 KV    DIS            .000         .000      P
          EHAGERST     OP     BUSTIE   138 KV    CB             .000         .000      P
          ANTIETAM     OP     T3 DIS   138 KV    DIS            .000         .000      P
          ANTIETAM     OP     BUS TIE  138 KV    CB             .000         .000      P
          ANTIETAM     L      ANT-EHA  138 KV                   .000         .000      P
          ANTIETAM     LD     T2       138 KV                   .000         .000      P
          ANTIETAM     OP     REID     138 KV    DIS            .000         .000      P
          ANTIETAM     LD     T3       138 KV                   .000         .000      P
          ANTIETAM     LD     T1       138 KV                   .000         .000      P
          REID         OP     ANTIETAM 138 KV    CB             .000         .000      P
13420    REID-ANTRIM-GUILFORD (APS)                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ANTRIM       OP     REID     138 KV    DIS            .000         .000      P
          REID         OP     ANTRIM   138 KV    CB             .000         .000      P
          ANTRIM       LD     T61      138 KV                   .000         .000      P
          ANTRIM       OP     T62 DIS  138 KV    DIS            .000         .000      P
          GUILFORD     OP     ANTRIM   138 KV    CB             .000         .000      P
          ANTRIM       L      ANT-REI  138 KV                   .000         .000      P
          ANTRIM       L      ANT-GUI  138 KV                   .000         .000      P
          ANTRIM       LD     T62      138 KV                   .000         .000      P
          ANTRIM       OP     BUS TIE  138 KV    DIS            .000         .000      P
          ANTRIM       OP     GUILFORD 138 KV    DIS            .000         .000      P
          ANTRIM       OP     T61 DIS  138 KV    DIS            .000         .000      P
13430    L230.Aqueduct-DickersonH.23101/235                Y Y Y S Y Y N N     YNNNNNNNNNNYNNNNNNNNNNNYN YNNNNNNNNNNYNNNNNNNNNNNYN
          AQUEDUCT     L      AQU-DIC  230 KV                   .000         .000       
          DICKERSH     OP     411C     230 KV    CB             .000         .000       
          AQUEDUCT     OP     DICKERCB 230 KV    CB             .000         .000       
13440    L230.Aqueduct-Doubs.201-1                         Y Y Y S Y Y N N     YNNNNNNNNNNYNNNNNNNNNNNYN YNNNNNNNNNNYNNNNNNNNNNNYN
          AQUEDUCT     L      AQU-DOU  230 KV                   .000         .000       
          DOUBS        OP     DJ4 CB   230 KV    CB             .000         .000       
          DOUBS        OP     DJ3 CB   230 KV    CB             .000         .000       
          AQUEDUCT     OP     DOUBSCB  230 KV    CB             .000         .000       
13450    230/35.Aqueduct.T1                                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          AQUEDUCT     L      AQU-DOU  230 KV                   .000         .000      P
          AQUEDUCT     OP     T1CB     35 KV     CB             .000         .000      P
          AQUEDUCT     OP     DOUBSCB  230 KV    CB             .000         .000      P
          AQUEDUCT     X      TR1      230 KV                   .000         .000      P
          AQUEDUCT     L      AQU-DIC  230 KV                   .000         .000      P
          AQUEDUCT     OP     DICKERCB 230 KV    CB             .000         .000      P
13460    L138.Armstrong-Burma                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BURMA        L      ARM-BUR  138 KV                   .000         .000      P
          ARMSTRON     OP     BURMA    138 KV    CB             .000         .000      P
          BURMA        OP     ARMSTRON 138 KV    CB             .000         .000      P
13470    L138.Armstrng-Kitanng-GarretJct-BigPineTap-KisKVlyY Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KITTANNI     OP     GARRNJCT 138 KV    CB             .000         .000       
          ARMSTRON     OP     GARRNJCT 138 KV    CB             .000         .000       
          KISKIVAL     OP     GARRNJCT 138 KV    CB             .000         .000       
          GARRNJCT     OP     DUMARM   138 KV    DIS            .000         .000       
          BIGPINET     OP     CUST     138 KV    DIS            .000         .000       
          BIGPINET     L      BIG-KIS  138 KV                   .000         .000       
          GARRNJCT     L      GAR-KIT  138 KV                   .000         .000       
          BIGPINET     OP     GAR      138 KV    DIS            .000         .000       
          GARRNJCT     L      BIG-GAR  138 KV                   .000         .000       
          GARRNJCT     OP     DUMKIT   138 KV    DIS            .000         .000       
          GARRNJCT     OP     DUM1     138 KV    DIS            .000         .000       
          GARRNJCT     L      ARM-GAR  138 KV                   .000         .000       
          BIGPINET     OP     KISK     138 KV    DIS            .000         .000       
13480    L138.Armstrong-Kittanning                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ARMSTRON     OP     KITTANNI 138 KV    CB             .000         .000       
          KITTANNI     OP     ARMSTRON 138 KV    CB             .000         .000       
          KITTANNI     L      ARM-KIT  138 KV                   .000         .000       
13490    L138.Armstrong-NewBethlehem-Brookville.1101       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ARMSTRON     OP     NEWBETHL 138 KV    CB             .000         .000       
          BROOKVIL     LD     1 TX     138 KV                   .000         .000       
          NEWBETHL     L      BRO-NEW  138 KV                   .000         .000       
          NEWBETHL     LD     T62      138 KV                   .000         .000       
          BROOKVIL     OP     BSSEC138 138 KV    CB             .000         .000       
          BROOKVIL     OP     ARMST138 138 KV    DIS            .000         .000       
          NEWBETHL     L      ARM-NEW  138 KV                   .000         .000       
13500    L138.Armstrong-Kissijct-Burma-Karnscity           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BURMA        OP     KISSINGE 138 KV    CB             .000         .000       
          KISSIJCT     OP     ARMSTRON 138 KV    DIS            .000         .000       
          KISSIJCT     OP     DUMBUR   138 KV    DIS            .000         .000       
          KISSIJCT     L      BUR-KIS  138 KV                   .000         .000       
          KISSIJCT     OP     KARNSCIT 138 KV    DIS            .000         .000       
          ARMSTRON     OP     KISSINGE 138 KV    CB             .000         .000       
          KARNSCIT     OP     KISSIJCT 138 KV    CB             .000         .000       
          KISSIJCT     L      ARM-KIS  138 KV                   .000         .000       
          KISSIJCT     L      KAR-KIS  138 KV                   .000         .000       
13530    L138.Arroyo-ArTap-SChstr-ELiverPo-WylieRidge(APS) Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SCHESTER     OP     EASTLIVE 138 KV    DIS            .000         .000       
          ARRJCT       OP     WYLIERID 138 KV    DIS            .000         .000       
          ARROYO       OP     QUAKERST 138 KV    CB             .000         .000       
          WYLIERID     OP     W2       138 KV    CB             .000         .000       
          ELIVERP2     L      ELI-STA1 69 KV                    .000         .000       
          WYLIERID     OP     W3       138 KV    CB             .000         .000       
          ARROYO       OP     BUSTIE   138 KV    CB             .000         .000       
          SCHESTER     OP     ARTAP    138 KV    DIS            .000         .000       
          ARROYO       LD     T2       138 KV                   .000         .000       
          SCHESTER     L      ELI-SCH  138 KV                   .000         .000       
          ELIVERP2     OP     B        69 KV     CB             .000         .000       
          ARRJCT       OP     DUM ARR  138 KV    DIS            .000         .000       
          ARRJCT       OP     SCHESTER 138 KV    DIS            .000         .000       
          ARROYO       L      ARR-QUA  138 KV                   .000         .000       
          ARROYO       OP     ARTAP    138 KV    DIS            .000         .000       
          SCHESTER     LD     T1       138 KV                   .000         .000       
          ARRJCT       L      ARR-ART  138 KV                   .000         .000       
          ARRJCT       L      ART-WYL  138 KV                   .000         .000       
          SCHESTER     OP     T1 DIS   138 KV    DIS            .000         .000       
          ELIVERP2     OP     A        69 KV     CB             .000         .000       
          ARRJCT       L      ART-SCH  138 KV                   .000         .000       
          ELIVERP2     X      1        138 KV                   .000         .000       
          ELIVERP2     L      ELI-SCA1 69 KV                    .000         .000       
          ELIVERP2     CP     CAP1     69 KV                    .000         .000       
13540    BACKFORK-COWEN-CRUPPERNECK (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BACKFORK     OP     COW DIS  138 KV    DIS            .000         .000      P
          COWEN        OP     BUSTIE   138 KV    DIS            .000         .000      P
          COWEN        OP     T2 DIS   138 KV    DIS            .000         .000      P
          COWEN        OP     BACKFORK 138 KV    DIS            .000         .000      P
          COWEN        LD     T2       138 KV                   .000         .000      P
          COWEN        OP     T1 DIS   138 KV    DIS            .000         .000      P
          COWEN        OP     CRUPPERN 138 KV    DIS            .000         .000      P
          CRUPPERN     OP     COWEN    138 KV    CB             .000         .000      P
          COWEN        L      BAC-COW  138 KV                   .000         .000      P
          COWEN        LD     T1       138 KV                   .000         .000      P
          COWEN        L      COW-CRU  138 KV                   .000         .000      P
13550    BACKFORK-PICKENS (APS)                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PICKENS      OP     BACKFORK 138 KV    CB             .000         .000      P
          PICKENS      L      BAC-PIC  138 KV                   .000         .000      P
          BACKFORK     OP     PICK DIS 138 KV    DIS            .000         .000      P
13560    POWELL-BAYS-WOLFRUN-SUTTONHILL-SUTTON (APS)       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SUTTONHI     X      TR1      138 KV                   .000         .000      P
          SUTTONTP     OP     1054     138 KV    DIS            .000         .000      P
          POWELLMT     OP     BAYS     138 KV    CB             .000         .000      P
          SUTTON       L      SUT-SUT  138 KV                   .000         .000      P
          SUTTONTP     OP     DUM      138 KV    DIS            .000         .000      P
          WOLFRUN      L      SUT-WOL  138 KV                   .000         .000      P
          BAYS         L      BAY-WOL  138 KV                   .000         .000      P
          SUTTON       OP     SUTTONHI 138 KV    DIS            .000         .000      P
          WOLFRUN      OP     DUMBAY   138 KV    DIS            .000         .000      P
          BAYS         OP     POWELLMO 138 KV    DIS            .000         .000      P
          BAYS         OP     T1 DIS   138 KV    DIS            .000         .000      P
          SUTTONTP     OP     1035     138 KV    DIS            .000         .000      P
          SUTTONHI     OP     291J     138 KV    DIS            .000         .000      P
          WOLFRUN      LD     WOLFRUN  138 KV                   .000         .000      P
          BAYS         LD     T1       138 KV                   .000         .000      P
          WOLFRUN      OP     DUMSUT   138 KV    DIS            .000         .000      P
          BAYS         OP     WOLFRUN  138 KV    DIS            .000         .000      P
          WOLFRUN      OP     D1078    138 KV    DIS            .000         .000      P
          BAYS         L      BAY-POW  138 KV                   .000         .000      P
13570    500/138.Bedington.T1&T3 (Sctnlz F)                Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNYYNNN NNNNNNNNNNNNNNNNNNNNYYNNN
          BEDINGTO     X      TRAN  1  500 KV                   .000         .000      P
          BEDINGTO     OP     BDL2 CB  500 KV    CB             .000         .000      P
          BEDINGTO     OP     BD5      138 KV    CB             .000         .000      P
          BEDINGTO     OP     BD4      138 KV    CB             .000         .000      P
          BEDINGTO     X      TRAN  3  500 KV                   .000         .000      P
          BEDINGTO     OP     BD1      138 KV    CB             .000         .000      P
          BEDINGTO     OP     BD2      138 KV    CB             .000         .000      P
          BEDINGTO     OP     BDL3 CB  500 KV    CB             .000         .000      P
13580    500/138.Bedington.T1 (Sctnlz)                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BEDINGTO     OP     TRAN1HS  500 KV    CB             .000         .000      P
          BEDINGTO     X      TRAN  1  500 KV                   .000         .000      P
          BEDINGTO     OP     BD2      138 KV    CB             .000         .000      P
          BEDINGTO     OP     BD1      138 KV    CB             .000         .000      P
13590    500/138.Bedington.T2 + 500.Cap.2&3 (Sctnlz)       Y Y Y S Y Y N N     YNNNNYYNNNNNNNNNNNNNNNNYN YNNNNYYNNNNNNNNNNNNNNNNYN
          BEDINGTO     OP     2CAPBDL7 500 KV    CB             .000         .000      P
          BEDINGTO     OP     BD8      138 KV    CB             .000         .000      P
          BEDINGTO     X      TRAN  2  500 KV                   .000         .000      P
          BEDINGTO     OP     BD7      138 KV    CB             .000         .000      P
          BEDINGTO     CP     CAP3     500 KV                   .000         .000      P
          BEDINGTO     OP     TRAN2HS  500 KV    CB             .000         .000      P
          BEDINGTO     OP     3CAPBDL8 500 KV    CB             .000         .000      P
          BEDINGTO     CP     CAP2     500 KV                   .000         .000      P
13600    500/138.Bedington.T3 (Sctnlz)                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BEDINGTO     OP     TRAN3HS  500 KV    CB             .000         .000      P
          BEDINGTO     OP     BD4      138 KV    CB             .000         .000      P
          BEDINGTO     OP     BD5      138 KV    CB             .000         .000      P
          BEDINGTO     X      TRAN  3  500 KV                   .000         .000      P
13610    500/138.Bedington.T4 + 500.Cap.2&3 (Sctnlz)       Y Y Y S Y Y N N     YNNNNYYNNNNNNNNNNNNNNNNYN YNNNNYYNNNNNNNNNNNNNNNNYN
          BEDINGTO     CP     CAP2     500 KV                   .000         .000      P
          BEDINGTO     CP     CAP3     500 KV                   .000         .000      P
          BEDINGTO     OP     TRAN4HS  500 KV    CB             .000         .000      P
          BEDINGTO     OP     BD11     138 KV    CB             .000         .000      P
          BEDINGTO     OP     BD10     138 KV    CB             .000         .000      P
          BEDINGTO     X      TRAN  4  500 KV                   .000         .000      P
          BEDINGTO     OP     3CAPBDL8 500 KV    CB             .000         .000      P
          BEDINGTO     OP     2CAPBDL7 500 KV    CB             .000         .000      P
13620    500/138.Bedington.T2&T4 + 500.Cap.2&3 (Sctnlz F)  Y Y Y S Y Y N N     NNNNNYYNNNNNNNNNNNNNYYNNN NNNNNYYNNNNNNNNNNNNNYYNNN
          BEDINGTO     OP     BD11     138 KV    CB             .000         .000      P
          BEDINGTO     CP     CAP2     500 KV                   .000         .000      P
          BEDINGTO     OP     BDL4 CB  500 KV    CB             .000         .000      P
          BEDINGTO     X      TRAN  2  500 KV                   .000         .000      P
          BEDINGTO     OP     BDL1 CB  500 KV    CB             .000         .000      P
          BEDINGTO     OP     3CAPBDL8 500 KV    CB             .000         .000      P
          BEDINGTO     OP     BD10     138 KV    CB             .000         .000      P
          BEDINGTO     OP     BD7      138 KV    CB             .000         .000      P
          BEDINGTO     X      TRAN  4  500 KV                   .000         .000      P
          BEDINGTO     CP     CAP3     500 KV                   .000         .000      P
          BEDINGTO     OP     2CAPBDL7 500 KV    CB             .000         .000      P
          BEDINGTO     OP     BD8      138 KV    CB             .000         .000      P
13630    L138.Bedington-Marlowe                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MARLOWE      L      BED-MAR  138 KV                   .000         .000      P
          BEDINGTO     OP     BD2      138 KV    CB             .000         .000      P
          MARLOWE      OP     BEDINGT1 138 KV    CB             .000         .000      P
          BEDINGTO     OP     BD3      138 KV    CB             .000         .000      P
13640    BEDINGTO-MARLOWE BMR (APS)                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BEDINGTO     OP     BD5      138 KV    CB             .000         .000      P
          MARLOWE      L      BED-MAR2 138 KV                   .000         .000      P
          BEDINGTO     OP     BD6      138 KV    CB             .000         .000      P
          MARLOWE      OP     BEDINGT2 138 KV    CB             .000         .000      P
13650    BEDINGTO-OPEQUON (APS)                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OPEQUON      L      BED-OPE  138 KV                   .000         .000      P
          BEDINGTO     OP     BD11     138 KV    CB             .000         .000      P
          OPEQUON      OP     BUSTIE   138 KV    CB             .000         .000      P
          BEDINGTO     OP     BD12     138 KV    CB             .000         .000      P
          OPEQUON      OP     BEDINGTO 138 KV    DIS            .000         .000      P
13660    L138.Bedington-Shepherdstown                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BEDINGTO     OP     BD9      138 KV    CB             .000         .000      P
          BEDINGTO     L      BED-SHE  138 KV                   .000         .000      P
          SHEPERDS     OP     BUSTIE   138 KV    CB             .000         .000      P
          SHEPERDS     OP     BEDINGTO 138 KV    DIS            .000         .000      P
          BEDINGTO     OP     BD8      138 KV    CB             .000         .000      P
          SHEPERDS     LD     T2       138 KV                   .000         .000      P
13670    L138.Bedington-Harmony Jct-Marlowe-Cherry Run     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MARLOWE      OP     HARMOJCT 138 KV    CB             .000         .000      P
          BEDINGTO     L      BED-HAR  138 KV                   .000         .000      P
          BEDINGTO     OP     BD13F    138 KV    CB             .000         .000      P
          CHERRYRN     OP     HARMOJCT 138 KV    DIS            .000         .000      P
          MARLOWE      L      HAR-MAR  138 KV                   .000         .000      P
          CHERRYRN     L      CHE-HAR  138 KV                   .000         .000      P
          HARMOJCT     OP     DUMMAR   138 KV    DIS            .000         .000      P
          HARMOJCT     OP     DUMCHE   138 KV    DIS            .000         .000      P
          HARMOJCT     OP     DUMBED   138 KV    DIS            .000         .000      P
          BEDINGTO     OP     BD14     138 KV    CB             .000         .000      P
13680    L138.Bedington-Nipetown-Reid                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BEDINGTO     L      BED-NIP  138 KV                   .000         .000      P
          BEDINGTO     OP     BD16     138 KV    CB             .000         .000      P
          NIPETOWN     OP     BUS TIE  138 KV    DIS            .000         .000      P
          NIPETOWN     OP     T1 DIS   138 KV    DIS            .000         .000      P
          REID         OP     NIPETOWN 138 KV    CB             .000         .000      P
          NIPETOWN     OP     BEDINGTO 138 KV    DIS            .000         .000      P
          BEDINGTO     OP     BD15     138 KV    CB             .000         .000      P
          NIPETOWN     OP     REID     138 KV    DIS            .000         .000      P
          REID         L      NIP-REI  138 KV                   .000         .000      P
          NIPETOWN     LD     T1       138 KV                   .000         .000      P
13690    LEADSVILLE-BELINGTON-UNIONRD-PRUNTYTOWN (APS)     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          UNIONRD      LD     T1       138 KV                   .000         .000      P
          BELINGTO     L      BEL-LEA  138 KV                   .000         .000      P
          LEADSVIL     OP     CB1      138 KV    CB             .000         .000      P
          BELINGTO     LD     T1       138 KV                   .000         .000      P
          BELINGTO     OP     SW-UN    138 KV    DIS            .000         .000      P
          BELINGTO     OP     T1 DIS   138 KV    DIS            .000         .000      P
          LEADSVIL     OP     CB2      138 KV    CB             .000         .000      P
          UNIONRD      OP     PRUNTYTO 138 KV    DIS            .000         .000      P
          PRUNTYTO     OP     P6       138 KV    CB             .000         .000      P
          PRUNTYTO     OP     P5       138 KV    CB             .000         .000      P
          UNIONRD      OP     T1 DIS   138 KV    DIS            .000         .000      P
          UNIONRD      OP     BELINGTO 138 KV    DIS            .000         .000      P
          LEADSVIL     OP     DUMBEL   138 KV    DIS            .000         .000      P
          PRUNTYTO     L      PRU-UNI  138 KV                   .000         .000      P
          BELINGTO     OP     LEADSVL  138 KV    DIS            .000         .000      P
          UNIONRD      L      BEL-UNI  138 KV                   .000         .000      P
13700    CHARLERO-BELMON-YUKON-SHEPLJCT-MITCHELL (APS)     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BELMON       OP     SHEPLERH 138 KV    DIS            .000         .000       
          MITCHELL     OP     SHEPLJCT 138 KV    CB             .000         .000       
          SHEPLJCT     L      SHE-SMI  138 KV                   .000         .000       
          SHEPLJCT     OP     DUMSMI   138 KV    DIS            .000         .000       
          SHEPLJCT     OP     DUMBEL   138 KV    DIS            .000         .000       
          BELMON       L      BEL-CHA  138 KV                   .000         .000       
          BELMON       OP     T61 DIS  138 KV    DIS            .000         .000       
          SMITHTON     OP     YUK2SHEP 138 KV    DIS            .000         .000       
          BELMON       OP     CHARLERO 138 KV    DIS            .000         .000       
          SMITHTON     OP     T62 DIS  138 KV    DIS            .000         .000       
          BELMON       OP     T62 DIS  138 KV    DIS            .000         .000       
          CHARLERO     OP     BELMON   138 KV    CB             .000         .000       
          BELMON       LD     T62      138 KV                   .000         .000       
          SHEPLJCT     OP     DUMMIT   138 KV    DIS            .000         .000       
          YUKON        L      SMI-YUK2 138 KV                   .000         .000       
          SHEPLJCT     L      BEL-SHE  138 KV                   .000         .000       
          SHEPLJCT     L      MIT-SHE  138 KV                   .000         .000       
          BELMON       LD     T61      138 KV                   .000         .000       
          SMITHTON     LD     T62      138 KV                   .000         .000       
          YUKON        OP     Y21      138 KV    CB             .000         .000       
          YUKON        OP     Y22      138 KV    CB             .000         .000       
13710    L765.Kammer-Belmont-Mountaineer+765/500.Belmont.T5Y Y Y 1 Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          KAMMER2      OP     DUM19089 765 KV    DIS            .000         .000       
          MOUNTAIN     OP     B1       765 KV    CB             .000         .000       
          BELMONT      OP     1172KAMM 765 KV    DIS            .000         .000       
          MOUNTAIN     OP     B2       765 KV    CB             .000         .000       
          BELMONT      OP     BL10     500 KV    CB             .000         .000       
          KAMMER2      OP     PP2      765 KV    CB             .000         .000       
          BELMONT      L      BEL-KAM  765 KV                   .000         .000       
          BELMONT      OP     5TX 765  765 KV    DIS            .000         .000       
          KAMMER2      OP     PP       765 KV    CB             .000         .000       
          BELMONT      OP     1171MOUN 765 KV    DIS            .000         .000       
          BELMONT      OP     BL12     500 KV    CB             .000         .000       
          BELMONT      L      BEL-MOU  765 KV                   .000         .000       
          BELMONT      X      TRAN  5  765 KV                   .000         .000       
          MOUNTAIN     OP     DUM19090 765 KV    DIS            .000         .000       
13720    L500.Belmont-Harrison                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          HARR APS     OP     BELMONT  500 KV    DIS            .000         .000      P
          BELMONT      OP     BL7      500 KV    CB             .000         .000      P
          BELMONT      OP     BL9      500 KV    CB             .000         .000      P
          BELMONT      OP     HARR LS  500 KV    DIS            .000         .000      P
          HARR APS     OP     HL11 CB  500 KV    CB             .000         .000      P
          HARR APS     OP     HL12 CB  500 KV    CB             .000         .000      P
          BELMONT      L      BEL-HAR  500 KV                   .000         .000      P
13730    500/138.Belmont.T1&T2 (Sctnlz F)                  Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNYYYNN NNNNNNNNNNNNNNNNNNNNYYYNN
          BELMONT      OP     BL2      500 KV    CB             .000         .000       
          BELMONT      X      TRAN  2  500 KV                   .000         .000       
          BELMONT      OP     B14      138 KV    CB             .000         .000       
          BELMONT      X      TRAN  1  500 KV                   .000         .000       
          BELMONT      OP     BL7      500 KV    CB             .000         .000       
          BELMONT      OP     B10      138 KV    CB             .000         .000       
          BELMONT      OP     BL5      500 KV    CB             .000         .000       
          BELMONT      OP     B13      138 KV    CB             .000         .000       
          BELMONT      OP     B11      138 KV    CB             .000         .000       
          BELMONT      OP     BL10     500 KV    CB             .000         .000       
13740    500/138.Belmont.Tran1 (Sctnlz)                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          BELMONT      OP     TX1 500  500 KV    DIS            .000         .000       
          BELMONT      OP     B11      138 KV    CB             .000         .000       
          BELMONT      OP     B10      138 KV    CB             .000         .000       
          BELMONT      X      TRAN  1  500 KV                   .000         .000       
13750    500/138.Belmont.Tran2 (Sctnlz)                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          BELMONT      OP     B14      138 KV    CB             .000         .000      P
          BELMONT      X      TRAN  2  500 KV                   .000         .000      P
          BELMONT      OP     TX2 500  500 KV    DIS            .000         .000      P
          BELMONT      OP     B13      138 KV    CB             .000         .000      P
13760    500/138.Belmont.Tran3                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          BELMONT      OP     BL9      500 KV    CB             .000         .000      P
          BELMONT      OP     BL6      500 KV    CB             .000         .000      P
          BELMONT      X      TRAN  3  500 KV                   .000         .000      P
          BELMONT      OP     B16      138 KV    CB             .000         .000      P
          BELMONT      OP     BL12     500 KV    CB             .000         .000      P
          BELMONT      OP     B17      138 KV    CB             .000         .000      P
          BELMONT      OP     BL3      500 KV    CB             .000         .000      P
13780    L69.HaringsCorner-Montvale                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARINGSC     OP     658-30-2 69 KV     CB             .000         .000       
          HARINGSC     L      HAR-MON  69 KV                    .000         .000       
          MONTVALE     OP     658-29-2 69 KV     CB             .000         .000       
13790    L138.Belmont-Edgelawn.628                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDGELAWN     L      BEL-EDG  138 KV                   .000         .000      P
          EDGELAWN     OP     BELMONT  138 KV    CB             .000         .000      P
          BELMONT      OP     B8       138 KV    CB             .000         .000      P
          BELMONT      OP     B7       138 KV    CB             .000         .000      P
13800    L138.Belmont-Oak Grove.606                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OAKG APS     OP     2        138 KV    CB             .000         .000      P
          BELMONT      L      BEL-OAK  138 KV                   .000         .000      P
          BELMONT      OP     B11      138 KV    CB             .000         .000      P
          BELMONT      OP     B12      138 KV    CB             .000         .000      P
          OAKG APS     OP     3        138 KV    CB             .000         .000      P
13810    L138.Belmont-Trissler.604                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TRISSLER     L      BEL-TRI  138 KV                   .000         .000      P
          BELMONT      OP     B8       138 KV    CB             .000         .000      P
          TRISSLER     OP     BELMONT4 138 KV    CB             .000         .000      P
          BELMONT      OP     B9       138 KV    CB             .000         .000      P
13820    L138.Belmont-Trissler.648                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TRISSLER     OP     BELMONT8 138 KV    CB             .000         .000      P
          TRISSLER     L      BEL-TRI2 138 KV                   .000         .000      P
          BELMONT      OP     B18      138 KV    CB             .000         .000      P
          BELMONT      OP     B17      138 KV    CB             .000         .000      P
13830    L115.Pamplin-RedHouse-SouthCreek.1006             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PAMPLIN      OP     100642   115 KV    CB             .000         .000      P
          PAMPLIN      OP     154T1006 115 KV    CB             .000         .000      P
          STHCREEK     L      1006A    115 KV                   .000         .000      P
          PAMPLIN      L      1006C    115 KV                   .000         .000      P
          STHCREEK     X      TX2      115 KV                   .000         .000      P
          REDHSEDP     L      1006B    115 KV                   .000         .000      P
13840    L138.Parkersburg-Belpre-Degussa-Corner            Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          BELPRE       OP     T1 DIS   138 KV    DIS            .000         .000      P
          DEGUSSA      OP     W        138 KV    DIS            .000         .000      P
          CORNER       L      COR-DEG  138 KV                   .000         .000      P
          BELPRE       OP     G        138 KV    CB             .000         .000      P
          DEGUSSA      LD     DEGUSSA  138 KV                   .000         .000      P
          DEGUSSA      OP     DEG CB   138 KV    CB             .000         .000      P
          BELPRE       OP     T2 DIS   138 KV    DIS            .000         .000      P
          BELPRE       OP     H        138 KV    CB             .000         .000      P
          PARKERSB     OP     BELPRE   138 KV    CB             .000         .000      P
          CORNER       OP     DEGUSRES 138 KV    DIS            .000         .000      P
          DEGUSSA      OP     Y        138 KV    DIS            .000         .000      P
          BELPRE       L      BEL-DEG  138 KV                   .000         .000      P
          BELPRE       LD     T1       138 KV                   .000         .000      P
          BELPRE       LD     T2       138 KV                   .000         .000      P
          BELPRE       OP     BUSTIE   138 KV    DIS            .000         .000      P
          CORNER       OP     J        138 KV    CB             .000         .000      P
          BELPRE       L      BEL-PAR  138 KV                   .000         .000      P
13860    L138.Page-Bethel-Riverton                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BETHEL       OP     DUMRIV   138 KV    DIS            .000         .000      P
          BETHEL       OP     DUMPAG   138 KV    DIS            .000         .000      P
          PAGE         OP     BETHEL   138 KV    CB             .000         .000      P
          BETHEL       L      BET-PAG  138 KV                   .000         .000      P
          RIVERTON     OP     BETHELLU 138 KV    CB             .000         .000      P
          BETHEL       L      BET-RIVU 138 KV                   .000         .000      P
13870    BETHELBO-CONNELSV (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CONNELSV     OP     BETHELBO 138 KV    CB             .000         .000      P
          BETHELBO     L      BET-CON  138 KV                   .000         .000      P
          BETHELBO     OP     CONNELLS 138 KV    CB             .000         .000      P
13880    BETHELBO-YUKON (APS)                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          YUKON        L      BET-YUK  138 KV                   .000         .000      P
          YUKON        OP     Y13      138 KV    CB             .000         .000      P
          YUKON        OP     Y2       138 KV    CB             .000         .000      P
          BETHELBO     OP     YUKON    138 KV    CB             .000         .000      P
13890    BETHELBO-SUNION-GANS-LAKELYNN (APS)               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SUNION       OP     GANS     138 KV    DIS            .000         .000       
          GANS         L      GAN-LAK  138 KV                   .000         .000       
          NUTAP2       OP     DUMBET   138 KV    DIS            .000         .000       
          SUNION       OP     BUS TIE  138 KV    DIS            .000         .000       
          NUTAP2       L      NUN-NUT2 138 KV                   .000         .000       
          GANS         OP     SS DIS   138 KV    DIS            .000         .000       
          BETHELBO     OP     NU TP2   138 KV    CB             .000         .000       
          GANS         U      GEN 9    138 KV                   .000         .000       
          SUNION       OP     T61 DIS  138 KV    DIS            .000         .000       
          NUNION       LD     T62      138 KV                   .000         .000       
          SUNION       LD     T62      138 KV                   .000         .000       
          GANS         OP     GEN8 CB  138 KV    CB             .000         .000       
          SUNION       OP     T62 DIS  138 KV    DIS            .000         .000       
          NUTAP2       OP     DUMNOR   138 KV    DIS            .000         .000       
          SUNION       OP     NU TP2   138 KV    DIS            .000         .000       
          SUNION       LD     T61      138 KV                   .000         .000       
          GANS         U      GEN 8    138 KV                   .000         .000       
          GANS         OP     LAKELYNN 138 KV    DIS            .000         .000       
          GANS         L      GAN-SUN  138 KV                   .000         .000       
          GANS         OP     BUS TIE  138 KV    DIS            .000         .000       
          NUTAP2       L      NUT-SUN  138 KV                   .000         .000       
          LAKELYNN     OP     GANS     138 KV    CB             .000         .000       
          BETHELBO     L      BET-NUT2 138 KV                   .000         .000       
          NUTAP2       OP     DUMSOU   138 KV    DIS            .000         .000       
          NUNION       OP     T62 DIS  138 KV    DIS            .000         .000       
          GANS         OP     GEN CB   138 KV    CB             .000         .000       
          NUNION       OP     NU TP2   138 KV    DIS            .000         .000       
          GANS         OP     GEN9 CB  138 KV    CB             .000         .000       
          GANS         LD     SS LOAD  138 KV                   .000         .000       
          GANS         OP     S UNION  138 KV    DIS            .000         .000       
13900    BETHELPA-PETERS (APS)                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PETERS       OP     1-2B     138 KV    CB             .000         .000      P
13910    BETHELPA-STCL APS (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STCL APS     OP     BUSTIE   138 KV    CB             .000         .000      P
          STCL APS     OP     T61 DIS  138 KV    DIS            .000         .000      P
          STCL APS     LD     T61      138 KV                   .000         .000      P
          BETHELPA     L      BET-STC  138 KV                   .000         .000      P
          BETHELPA     OP     ST CLAIR 138 KV    CB             .000         .000      P
13920    SFAYETTE-STCL APS (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SFAYETTE     OP     BUSTIE   138 KV    CB             .000         .000      P
          STCL APS     LD     T62      138 KV                   .000         .000      P
          STCL APS     OP     BUSTIE   138 KV    CB             .000         .000      P
          SFAYETTE     L      SFA-STC  138 KV                   .000         .000      P
          STCL APS     OP     T62 DIS  138 KV    DIS            .000         .000      P
13930    CECI APS-SFAYETTE (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CECI APS     OP     ST.CLAIR 138 KV    CB             .000         .000       
          SFAYETTE     LD     T61      138 KV                   .000         .000       
          SFAYETTE     OP     BUSTIE   138 KV    CB             .000         .000       
          SFAYETTE     OP     SW-T61   138 KV    DIS            .000         .000       
          CECI APS     L      CEC-SFA  138 KV                   .000         .000       
13940    PICKENS-DURBIN-BEVERLY-LOUGHSLA (APS)             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BEVERLY      OP     T1 DIS   138 KV    DIS            .000         .000       
          BEVERLY      L      BEV-DUR  138 KV                   .000         .000       
          BEVERLY      LD     T1       138 KV                   .000         .000       
          DURBINTP     OP     1010     138 KV    DIS            .000         .000       
          DURBIN       CP     CAP1     138 KV                   .000         .000       
          PICKENS      OP     DURBIN   138 KV    CB             .000         .000       
          BEVERLY      OP     LOUGHSLA 138 KV    DIS            .000         .000       
          DURBIN       OP     652J     138 KV    DIS            .000         .000       
          DURBIN       X      TR1      138 KV                   .000         .000       
          PICKENS      L      DUR-PIC  138 KV                   .000         .000       
          DURBINTP     OP     1007     138 KV    DIS            .000         .000       
          BEVERLY      OP     DURBIN   138 KV    DIS            .000         .000       
          DURBINTP     OP     1072     138 KV    DIS            .000         .000       
          LOUGHSLA     OP     BEVERLY  138 KV    CB             .000         .000       
          BEVERLY      L      BEV-LOU  138 KV                   .000         .000       
          DURBIN       OP     CAP1 CB  138 KV    CB             .000         .000       
13950    500/138.BlackOak.T3 + BlackOak.SVC + BlackOak.CapsY Y Y S Y Y N N     YNNNNYYYNNNNNNYNYNNNNNNYN YNNNNYYYNNNNNNYNYNNNNNNYN
          BLACKOAK     OP     BOL1 CB  500 KV    CB             .000         .000      P
          BLACKOAK     OP     3XFMRBO3 138 KV    CB             .000         .000      P
          BLACKOAK     X      TRAN  3  500 KV                   .000         .000      P
          BLACKOAK     U      SVC      500 KV                   .000         .000      P
          BLACKOAK     OP     BOL3 CB  500 KV    CB             .000         .000      P
          BLACKOAK     CP     CAP2     500 KV                   .000         .000      P
          BLACKOAK     OP     BOL10 CB 500 KV    CB             .000         .000      P
          BLACKOAK     OP     3CAPBOL9 500 KV    CB             .000         .000      P
          BLACKOAK     OP     2CAPBOL7 500 KV    CB             .000         .000      P
          BLACKOAK     CP     CAP3     500 KV                   .000         .000      P
13960    L138.BlackOak-Junction                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JUNCTION     OP     BLACKOAK 138 KV    CB             .000         .000       
          BLACKOAK     OP     BO10     138 KV    CB             .000         .000       
          BLACKOAK     OP     BO9      138 KV    CB             .000         .000       
          JUNCTION     L      BLA-JUN  138 KV                   .000         .000       
13970    L138.BlackOak-ShortGap-Cumberland(APS)            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHORTGAP     OP     BUS TIE  138 KV    DIS            .000         .000       
          SHORTGAP     LD     T1       138 KV                   .000         .000       
          BLACKOAK     L      BLA-SHO  138 KV                   .000         .000       
          BLACKOAK     OP     BO13     138 KV    CB             .000         .000       
          CUMB APS     L      CUM-SHO  138 KV                   .000         .000       
          SHORTGAP     OP     CUMBERLA 138 KV    DIS            .000         .000       
          CUMB APS     OP     SHORTGAP 138 KV    CB             .000         .000       
          BLACKOAK     OP     BO12     138 KV    CB             .000         .000       
          SHORTGAP     OP     BLACKOAK 138 KV    DIS            .000         .000       
          SHORTGAP     OP     T1 DIS   138 KV    DIS            .000         .000       
13980    L138.Whiteley-Blacksville-MiracleRun-Fairview     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MIRACLER     OP     T2 CB    138 KV    CB             .000         .000       
          FAIR APS     OP     MIRACLER 138 KV    CB             .000         .000       
          BLACKSVI     OP     SW-WHT   138 KV    DIS            .000         .000       
          MIRACLER     OP     404J     138 KV    DIS            .000         .000       
          MIRACLER     OP     1013     138 KV    DIS            .000         .000       
          BLACKSVI     OP     BLACK CB 138 KV    CB             .000         .000       
          WHITELEY     OP     BLACK CB 138 KV    CB             .000         .000       
          BLACKSVI     L      BLA-MIR  138 KV                   .000         .000       
          MIRACLER     OP     1014     138 KV    DIS            .000         .000       
          FAIR APS     L      FAI-MIR  138 KV                   .000         .000       
          BLACKSVI     LD     BLACKSVI 138 KV                   .000         .000       
          BLACKSVI     OP     MIRACLER 138 KV    DIS            .000         .000       
          MIRACLER     OP     1022     138 KV    DIS            .000         .000       
          BLACKSVI     L      BLA-WHI  138 KV                   .000         .000       
13990    L138.Boonsboro-Marlowe                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MARLOWE      L      BOO-MAR  138 KV                   .000         .000       
          MARLOWE      OP     BOONSBOR 138 KV    CB             .000         .000       
          BOONSBOR     OP     MARLOWE  138 KV    CB             .000         .000       
14000    230/138.Boonsboro.T5                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FROSTOWN     OP     DUMBOON  230 KV    DIS            .000         .000       
          BOONSBOR     OP     T5 CB    230 KV    CB             .000         .000       
          BOONSBOR     OP     FROSTOWN 138 KV    CB             .000         .000       
          FROSTOWN     L      BOO-FRO  230 KV                   .000         .000       
14010    L138.Loyalhanna-BrackenJct-Luxor-EastGate-Youngwd Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EASTGATE     OP     T61 DIS  138 KV    DIS            .000         .000       
          LOYALHAN     L      BRA-LOY  138 KV                   .000         .000       
          EASTGATE     OP     BRACYOUN 138 KV    DIS            .000         .000       
          BRACKJCT     OP     DUMEAS   138 KV    DIS            .000         .000       
          EASTGATE     L      EAS-YOU  138 KV                   .000         .000       
          LUXOR        L      BRA-LUX  138 KV                   .000         .000       
          EASTGATE     OP     BUS TIE  138 KV    DIS            .000         .000       
          EASTGATE     L      BRA-EAS  138 KV                   .000         .000       
          EASTGATE     LD     T61      138 KV                   .000         .000       
          LOYALHAN     OP     BRACKJCT 138 KV    CB             .000         .000       
          EASTGATE     LD     T62      138 KV                   .000         .000       
          YOUNGWOO     OP     EASTGATE 138 KV    CB             .000         .000       
          BRACKJCT     OP     DUMLUX   138 KV    DIS            .000         .000       
          EASTGATE     OP     T62 DIS  138 KV    DIS            .000         .000       
          BRACKJCT     OP     DUMLOY   138 KV    DIS            .000         .000       
          LUXOR        OP     BRACKJCT 138 KV    CB             .000         .000       
14020    LUXOR-EASTGATE-SONY-KINGFARM (APS)                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SONY         LD     T62      138 KV                   .000         .000       
          SONY         OP     EASTGATE 138 KV    DIS            .000         .000       
          SONY         OP     T62 DIS  138 KV    DIS            .000         .000       
          SONY         LD     T61      138 KV                   .000         .000       
          LUXOR        OP     EASTGATE 138 KV    CB             .000         .000       
          SONY         L      EAS-SON  138 KV                   .000         .000       
          SONY         OP     KINGFARM 138 KV    DIS            .000         .000       
          SONY         OP     T61 DIS  138 KV    DIS            .000         .000       
          KINGFARM     OP     SONY     138 KV    DIS            .000         .000       
          SONY         L      KIN-SON  138 KV                   .000         .000       
          EASTGATE     OP     LUXOSONY 138 KV    DIS            .000         .000       
          SONY         OP     BUS TIE  138 KV    DIS            .000         .000       
          LUXOR        L      EAS-LUX  138 KV                   .000         .000       
14030    LUXOR-LOYALHAN (APS)                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LUXOR        OP     LOYALHAN 138 KV    CB             .000         .000      P
          LOYALHAN     OP     LUXOR    138 KV    CB             .000         .000      P
          LUXOR        L      LOY-LUX  138 KV                   .000         .000      P
14040    L138.Butler-CabreyJct-Bredinville-Cabot (APS)     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CABREJCT     OP     DUMBUT   138 KV    DIS            .000         .000       
          BUTL APS     OP     CABREJCT 138 KV    CB             .000         .000       
          CABREJCT     OP     DUMBRE   138 KV    DIS            .000         .000       
          CABREJCT     OP     DUMCAB   138 KV    DIS            .000         .000       
          BREDINVI     OP     CABREJCT 138 KV    CB             .000         .000       
          CABREJCT     L      BRE-CAB  138 KV                   .000         .000       
          CABOT        OP     C3       138 KV    CB             .000         .000       
          CABREJCT     L      CAB-CAB  138 KV                   .000         .000       
          CABOT        OP     C2       138 KV    CB             .000         .000       
          CABREJCT     L      BUT-CAB  138 KV                   .000         .000       
14050    BREDINVI-KILGO-MCCALMONT (APS)                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KILGO        OP     T61 DIS  138 KV    DIS            .000         .000      P
          KILGO        OP     BUS TIE  138 KV    DIS            .000         .000      P
          KILGO        LD     T62      138 KV                   .000         .000      P
          KILGO        OP     T62 DIS  138 KV    DIS            .000         .000      P
          MCCALMON     L      KIL-MCC  138 KV                   .000         .000      P
          KILGO        OP     MCCALMON 138 KV    DIS            .000         .000      P
          MCCALMON     OP     KILGO    138 KV    CB             .000         .000      P
          BREDINVI     L      BRE-KIL  138 KV                   .000         .000      P
          KILGO        LD     T61      138 KV                   .000         .000      P
          KILGO        OP     BREDINVI 138 KV    DIS            .000         .000      P
          BREDINVI     OP     KILGO    138 KV    CB             .000         .000      P
14060    BARNETTS RUN-BRID APS-GLENFALL (APS)              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BRID APS     OP     BUSTIE   138 KV    DIS            .000         .000      P
          BRID APS     L      BRI-GLE  138 KV                   .000         .000      P
          BRID APS     OP     T2 DIS   138 KV    DIS            .000         .000      P
          BRID APS     LD     T1       138 KV                   .000         .000      P
          GLENFALL     OP     BRIDGEPO 138 KV    CB             .000         .000      P
          BRID APS     LD     T2       138 KV                   .000         .000      P
          BARNETTS     OP     BRIDGECB 138 KV    CB             .000         .000      P
          BRID APS     OP     T1 DIS   138 KV    DIS            .000         .000      P
          BRID APS     OP     GLENFALL 138 KV    DIS            .000         .000      P
          BARNETTS     L      BAR-BRI  138 KV                   .000         .000      P
14070    SHINNSRN-BARNETTS RUN (APS)                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BARNETTS     OP     BRIDGECB 138 KV    CB             .000         .000      P
          SHINNSRN     OP     BUS TIE  138 KV    CB             .000         .000      P
          BARNETTS     LD     T1 HREA  138 KV                   .000         .000      P
          BARNETTS     L      BAR-SHI  138 KV                   .000         .000      P
14080    L138.PierPt-Brookhaven-SMorgantwn-Pricehill       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BROOKHAV     L      BRO-SMO  138 KV                   .000         .000      P
          SMORGANT     OP     T1 DIS   138 KV    DIS            .000         .000      P
          SMORGANT     OP     BUSTIE   138 KV    DIS            .000         .000      P
          BROOKHAV     OP     SABRATON 138 KV    DIS            .000         .000      P
          BROOKHAV     LD     T1       138 KV                   .000         .000      P
          SMORGANT     L      PRI-SMO  138 KV                   .000         .000      P
          BROOKHAV     OP     T1 DIS   138 KV    DIS            .000         .000      P
          BROOKHAV     L      BRO-PIE  138 KV                   .000         .000      P
          SMORGANT     OP     T2 DIS   138 KV    DIS            .000         .000      P
          SMORGANT     OP     SABRATON 138 KV    DIS            .000         .000      P
          SMORGANT     OP     PRICEHIL 138 KV    DIS            .000         .000      P
          SMORGANT     LD     T2       138 KV                   .000         .000      P
          PRICEHIL     OP     SOUTHMOR 138 KV    CB             .000         .000      P
          SMORGANT     LD     T1       138 KV                   .000         .000      P
          BROOKHAV     OP     PIERPONT 138 KV    DIS            .000         .000      P
14090    BUCKHANN-CORDERCR-PRUNTYTO (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CORDERCR     OP     PRUNTYTO 138 KV    DIS            .000         .000      P
          PRUNTYTO     OP     P2       138 KV    CB             .000         .000      P
          BUCKHANN     L      BUC-COR  138 KV                   .000         .000      P
          PRUNTYTO     L      COR-PRU  138 KV                   .000         .000      P
          PRUNTYTO     OP     P3       138 KV    CB             .000         .000      P
          BUCKHANN     OP     CORDERCR 138 KV    CB             .000         .000      P
          CORDERCR     OP     CORD DIS 138 KV    DIS            .000         .000      P
          CORDERCR     LD     CORDERCR 138 KV                   .000         .000      P
          CORDERCR     OP     BUCKHANN 138 KV    DIS            .000         .000      P
14100    BUCKHANN-FRENCHCR (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BUCKHANN     OP     FRENCHCR 138 KV    CB             .000         .000      P
          FRENCHCR     OP     BUCKHANN 138 KV    CB             .000         .000      P
          BUCKHANN     L      BUC-FRE  138 KV                   .000         .000      P
14110    BUCKHANN-NATIONAL-GLENFALL (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NATIONAL     OP     T1 CB    138 KV    CB             .000         .000       
          NATIONAL     OP     DUMGLE   138 KV    DIS            .000         .000       
          GLENFALL     L      GLE-NAT  138 KV                   .000         .000       
          NATIONAL     LD     T1       138 KV                   .000         .000       
          GLENFALL     OP     NATIONAL 138 KV    CB             .000         .000       
14120    L138.Buckhan-EBuckhan-Tallmans-RoarngCrk-LoughsLanY Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LOUGHSLA     CP     CAP1     138 KV                   .000         .000       
          TALLMANS     OP     DUMEAS   138 KV    DIS            .000         .000       
          EBUCKHAN     OP     BUCKHANN 138 KV    DIS            .000         .000       
          ROARCREK     L      ROR-TAL  138 KV                   .000         .000       
          TALLMANS     OP     T1 CB    138 KV    CB             .000         .000       
          EBUCKHAN     LD     T1       138 KV                   .000         .000       
          TALLMANS     LD     T1       138 KV                   .000         .000       
          EBUCKHAN     OP     TALLMANS 138 KV    DIS            .000         .000       
          EBUCKHAN     L      EBU-TAL  138 KV                   .000         .000       
          BUCKHANN     OP     EASTBUCK 138 KV    CB             .000         .000       
          EBUCKHAN     OP     T1 DIS   138 KV    DIS            .000         .000       
          LOUGHSLA     L      LOU-ROR  138 KV                   .000         .000       
          BUCKHANN     L      BUC-EBU  138 KV                   .000         .000       
          LOUGHSLA     OP     CAP1 DIS 138 KV    DIS            .000         .000       
          LOUGHSLA     OP     TALLMANS 138 KV    CB             .000         .000       
          EBUCKHAN     OP     BUSTIE   138 KV    DIS            .000         .000       
14130    WEIRTON-HAMIL-PARKVIEW-BUFFAJCT-CECIL-WINDSOR(APS)Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CECI APS     OP     BUFFAJCT 138 KV    CB             .000         .000      P
          HAMI APS     OP     DUMWEI   138 KV    DIS            .000         .000      P
          HAMI APS     OP     T61 DIS  138 KV    DIS            .000         .000      P
          HAMI APS     L      HAM-WEI  138 KV                   .000         .000      P
          BUFFAJCT     L      BUF-CEC  138 KV                   .000         .000      P
          PARKVIEW     OP     HAMILTON 138 KV    DIS            .000         .000      P
          HAMI APS     LD     T1       138 KV                   .000         .000      P
          BUFFAJCT     OP     DUMCEC   138 KV    DIS            .000         .000      P
          BUFFAJCT     OP     DUMWIN   138 KV    DIS            .000         .000      P
          BUFFAJCT     L      BUF-PAR  138 KV                   .000         .000      P
          WEIRTON      OP     HAMILTON 138 KV    CB             .000         .000      P
          PARKVIEW     OP     T2 DIS   138 KV    DIS            .000         .000      P
          BUFFAJCT     OP     PARKVIEW 138 KV    DIS            .000         .000      P
          PARKVIEW     OP     BUFFALOJ 138 KV    DIS            .000         .000      P
          PARKVIEW     OP     BUSTIE   138 KV    DIS            .000         .000      P
          PARKVIEW     OP     T1 DIS   138 KV    DIS            .000         .000      P
          HAMI APS     L      HAM-PAR  138 KV                   .000         .000      P
          BUFFAJCT     L      BUF-WIN  138 KV                   .000         .000      P
          HAMI APS     OP     PARKVIEW 138 KV    DIS            .000         .000      P
          HAMI APS     OP     T1 DIS   138 KV    DIS            .000         .000      P
          WIND APS     OP     BUFFAJCT 138 KV    CB             .000         .000      P
          PARKVIEW     LD     T2       138 KV                   .000         .000      P
          HAMI APS     LD     T61      138 KV                   .000         .000      P
          PARKVIEW     LD     T1       138 KV                   .000         .000      P
14140    HOUSEVIL-BULLCJCT-MCCALMON-CABOT (APS)            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BULLCJCT     OP     DUMHOU   138 KV    DIS            .000         .000       
          BULLCJCT     L      BUL-MOU  138 KV                   .000         .000       
          HOUSEVIL     OP     BULLCJCT 138 KV    DIS            .000         .000       
          MCCALMON     OP     BULCRJCT 138 KV    CB             .000         .000       
          BULLCJCT     OP     DUMMCC   138 KV    DIS            .000         .000       
          BULLCJCT     L      BUL-CAB  138 KV                   .000         .000       
          CABOT        OP     C17      138 KV    CB             .000         .000       
          BULLCJCT     OP     DUMCAB   138 KV    DIS            .000         .000       
          BULLCJCT     L      BUL-HOU  138 KV                   .000         .000       
          CABOT        OP     C16      138 KV    CB             .000         .000       
          MCCALMON     L      MCC-MOU  138 KV                   .000         .000       
14150    BURMA-CLARION-RIDG APS (APS)                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BURMA        OP     CLARION  138 KV    CB             .000         .000       
          CLARION      LD     T2       138 KV                   .000         .000       
          CLARION      LD     T62      138 KV                   .000         .000       
          CLARION      LD     T61      138 KV                   .000         .000       
          RIDG APS     L      CLA-RID  138 KV                   .000         .000       
          CLARION      OP     BURMA    138 KV    DIS            .000         .000       
          CLARION      OP     T2 DIS   138 KV    DIS            .000         .000       
          BURMA        L      BUR-CLA  138 KV                   .000         .000       
          RIDG APS     OP     CLARION  138 KV    CB             .000         .000       
          CLARION      OP     T61 DIS  138 KV    DIS            .000         .000       
          CLARION      OP     RIDGWAY  138 KV    DIS            .000         .000       
          CLARION      OP     T62 DIS  138 KV    DIS            .000         .000       
          CLARION      OP     BUS TIE  138 KV    DIS            .000         .000       
14160    L138.Butler-Cabot.West (APS)                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CABOT        OP     C2       138 KV    CB             .000         .000       
          BUTL APS     OP     CABOTW   138 KV    CB             .000         .000       
          CABOT        OP     C1       138 KV    CB             .000         .000       
          CABOT        L      BUT-CABW 138 KV                   .000         .000       
14170    L138.Butler-KarnsCity (APS)                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KARNSCIT     OP     BUTLER   138 KV    CB             .000         .000       
          BUTL APS     L      BUT-KAR  138 KV                   .000         .000       
          BUTL APS     OP     KARNSCIT 138 KV    CB             .000         .000       
14180    L138.Butler-Cabot.East (APS)                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CABOT        OP     C14      138 KV    CB             .000         .000       
          CABOT        OP     C15      138 KV    CB             .000         .000       
          BUTL APS     OP     CABOTE   138 KV    CB             .000         .000       
          CABOT        L      BUT-CABE 138 KV                   .000         .000       
14190    L138.Butler-ShanonManor-Krendale (APS)            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHANORMA     OP     T61 DIS  138 KV    DIS            .000         .000       
          KRENDALE     OP     SHANORMA 138 KV    CB             .000         .000       
          BUTL APS     L      BUT-SHA  138 KV                   .000         .000       
          SHANORMA     LD     T61      138 KV                   .000         .000       
          BUTL APS     OP     SHANORMA 138 KV    CB             .000         .000       
          SHANORMA     OP     KRENDALE 138 KV    DIS            .000         .000       
          SHANORMA     OP     BUTLER   138 KV    DIS            .000         .000       
          SHANORMA     OP     BUS TIE  138 KV    DIS            .000         .000       
          KRENDALE     L      KRE-SHA  138 KV                   .000         .000       
14200    500/138.Cabot.T2&T4 (Sctnlz F)                    Y Y Y S Y Y N N     NNNNNNNNNNYNNNNNNNNNYYNNN NNNNNNNNNNYNNNNNNNNNYYNNN
          CABOT        OP     CB 06    500 KV    CB             .000         .000       
          CABOT        OP     C7       138 KV    CB             .000         .000       
          CABOT        OP     C8       138 KV    CB             .000         .000       
          CABOT        X      TRAN  4  500 KV                   .000         .000       
          CABOT        X      TRAN  2  500 KV                   .000         .000       
          CABOT        OP     CB 02    500 KV    CB             .000         .000       
          CABOT        OP     C20      138 KV    CB             .000         .000       
14210    500/138.Cabot.T2 (Sctnlz)                         Y Y Y S Y Y N N     YNNNNNNNNNYNNNNNNNNNNNNYN YNNNNNNNNNYNNNNNNNNNNNNYN
          CABOT        X      TRAN  2  500 KV                   .000         .000       
          CABOT        OP     XF2      500 KV    CB             .000         .000       
          CABOT        OP     C20      138 KV    CB             .000         .000       
14220    500/138.Cabot.T4 (Sctnlz)                         Y Y Y S Y Y N N     YNNNNNNNNNYNNNNNNNNNNNNYN YNNNNNNNNNYNNNNNNNNNNNNYN
          CABOT        OP     C7       138 KV    CB             .000         .000       
          CABOT        OP     C8       138 KV    CB             .000         .000       
          CABOT        OP     XF4      500 KV    CB             .000         .000       
          CABOT        X      TRAN  4  500 KV                   .000         .000       
14230    CABOT-LAWSOJCT-MCCALMON-FAWN (APS)                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CABOT        OP     C5       138 KV    CB             .000         .000       
          LAWSOJCT     OP     DUMCAB   138 KV    DIS            .000         .000       
          CABOT        OP     C4       138 KV    CB             .000         .000       
          LAWSOJCT     OP     DUMFAW   138 KV    DIS            .000         .000       
          CABOT        L      CAB-LAW  138 KV                   .000         .000       
          FAWN         L      FAW-LAW  138 KV                   .000         .000       
          LAWSOJCT     OP     DUMMCC   138 KV    DIS            .000         .000       
          FAWN         OP     LAWSOJCT 138 KV    CB             .000         .000       
          MCCALMON     OP     LAWSOJCT 138 KV    CB             .000         .000       
          MCCALMON     L      LAW-MCC  138 KV                   .000         .000       
14240    CABOT-SAXONBURG (APS)                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SAXONBUR     OP     SW-T61   138 KV    DIS            .000         .000       
          CABOT        OP     C17      138 KV    CB             .000         .000       
          SAXONBUR     LD     T61      138 KV                   .000         .000       
          CABOT        OP     C18      138 KV    CB             .000         .000       
          CABOT        L      CAB-SAX  138 KV                   .000         .000       
14250    CABOT-WOODLAND-N.POINT-KISKIVAL (APS)             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NPOINTE2     L      NPO-WOO  138 KV                   .000         .000       
          WOODLAND     LD     T2       138 KV                   .000         .000       
          KISKIVAL     L      KIS-NPO  138 KV                   .000         .000       
          CABOT        L      CAB-WOO  138 KV                   .000         .000       
          WOODLAND     OP     DUMCAB   138 KV    DIS            .000         .000       
          NPOINTE2     OP     WOODLAND 138 KV    DIS            .000         .000       
          WOODLAND     OP     T2 DIS   138 KV    DIS            .000         .000       
          NPOINTE2     OP     KISKIVAL 138 KV    DIS            .000         .000       
          NPOINTE2     LD     T1       138 KV                   .000         .000       
          CABOT        OP     C8       138 KV    CB             .000         .000       
          CABOT        OP     C9       138 KV    CB             .000         .000       
14260    L138.LakeLynn-Lardin.2                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LAKELYNN     OP     LARDIN2  138 KV    CB             .000         .000       
          LARDIN       OP     L-6      138 KV    CB             .000         .000       
          LAKELYNN     L      LAK-LAR2 138 KV                   .000         .000       
          LARDIN       OP     L-3      138 KV    CB             .000         .000       
14280    L138.Lardin-ClarksvllJct-Emerld-Luzrn-Maldn-Charl Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CLRKSJCT     L      CLA-LUZ  138 KV                   .000         .000       
          CALIFORN     L      CAL-MAL  138 KV                   .000         .000       
          CHARLERO     OP     CALIFORN 138 KV    CB             .000         .000       
          LARDIN       OP     L-5      138 KV    CB             .000         .000       
          CALIFORN     L      CAL-CHA  138 KV                   .000         .000       
          LUZERNE      L      LUZ-MAL  138 KV                   .000         .000       
          LARDIN       OP     L-4      138 KV    CB             .000         .000       
          CLRKSJCT     L      CLA-EME  138 KV                   .000         .000       
          CLRKSJCT     L      CLA-LAR  138 KV                   .000         .000       
14290    SENECACA-CANAANVA-WILLIAM (APS)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WILLIAM      OP     CANAANVA 138 KV    CB             .000         .000       
          CANAANVA     OP     SENECACA 138 KV    DIS            .000         .000       
          CANAANVA     OP     BUSTIE   138 KV    DIS            .000         .000       
          CANAANVA     LD     T1       138 KV                   .000         .000       
          CANAANVA     OP     T2 DIS   138 KV    DIS            .000         .000       
          WILLIAM      L      CAN-WIL  138 KV                   .000         .000       
          CANAANVA     OP     WILLIAM  138 KV    DIS            .000         .000       
          SENECACA     L      CAN-SEN  138 KV                   .000         .000       
          CANAANVA     LD     T2       138 KV                   .000         .000       
          SENECACA     OP     CANAANVA 138 KV    CB             .000         .000       
          CANAANVA     OP     T1 DIS   138 KV    DIS            .000         .000       
14300    L230.CarbonCenter-Elko                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARBONCE     X      T1       230 KV                   .000         .000       
          CARBONCE     LD     T82      230 KV                   .000         .000       
          CARBONCE     OP     DUMELK   230 KV    DIS            .000         .000       
          ELKO         L      CAR-ELK  230 KV                   .000         .000       
          CARBONCE     OP     T1H      230 KV    CB             .000         .000       
          ELKO         OP     CARBONCE 230 KV    CB             .000         .000       
14310    L138.Elko-Carbonce-Williamet-Papercit (APS)       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARBONCE     OP     DUMELK   230 KV    DIS            .000         .000      P
          CARBONCE     L      CAR-WIL  138 KV                   .000         .000      P
          CARBONCE     OP     CARB JCT 138 KV    DIS            .000         .000      P
          PAPERCIT     OP     WILLAMET 138 KV    DIS            .000         .000      P
          CARBONCE     LD     T71      138 KV                   .000         .000      P
          WILLAMET     LD     T61      138 KV                   .000         .000      P
          CARBONCE     OP     DUMWIL   138 KV    DIS            .000         .000      P
          WILLAMET     OP     T61 DIS  138 KV    DIS            .000         .000      P
          PAPERCIT     OP     BUS TIE  138 KV    CB             .000         .000      P
          ELKO         OP     CARBONCE 138 KV    CB             .000         .000      P
          ELKO         L      CAR-ELK  138 KV                   .000         .000      P
          CARBONCE     OP     T1 CB    138 KV    CB             .000         .000      P
          WILLAMET     OP     CACJ     138 KV    DIS            .000         .000      P
          WILLAMET     OP     PCT      138 KV    DIS            .000         .000      P
          PAPERCIT     LD     T2       138 KV                   .000         .000      P
          PAPERCIT     L      PAP-WIL  138 KV                   .000         .000      P
14320    230/138.CarbonCenter.T1                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARBONCE     OP     T1 CB    138 KV    CB             .000         .000       
          CARBONCE     OP     T1H      230 KV    CB             .000         .000       
          CARBONCE     X      T1       230 KV                   .000         .000       
14330    GARRETT-CARLOJCT-RIDGELEY (APS)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RIDGELEY     L      CAR-RID  138 KV                   .000         .000       
          CARLOJCT     OP     RIDGELEY 138 KV    DIS            .000         .000       
          CARLOJCT     OP     T1 DIS   138 KV    DIS            .000         .000       
          CARLOJCT     LD     T1       138 KV                   .000         .000       
          GARRETT      OP     CARLOJCT 138 KV    CB             .000         .000       
          RIDGELEY     OP     CARLOJCT 138 KV    CB             .000         .000       
          CARLOJCT     OP     GARRETT  138 KV    DIS            .000         .000       
          GARRETT      L      CAR-GAR  138 KV                   .000         .000       
14340    L138.Weirton-Carnegie-Tidd.224                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARNEGIE     OP     CARDINAL 138 KV    DIS            .000         .000       
          CARNEGIE     LD     T2       138 KV                   .000         .000       
          CARNEGIE     OP     T2 DIS   138 KV    DIS            .000         .000       
          CARNEGIE     L      CAR-TID  138 KV                   .000         .000       
          CARNEGIE     OP     WEIRTON  138 KV    DIS            .000         .000       
          WEIRTON      L      CAR-WEI  138 KV                   .000         .000       
          WEIRTON      OP     CARNEGIE 138 KV    CB             .000         .000       
          TIDD_AEP     OP     D1       138 KV    CB             .000         .000       
          TIDD_AEP     OP     D        138 KV    CB             .000         .000       
14350    CARROLL-CATOCTIN (APS)                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARROLL      OP     CATOCTIN 138 KV    CB             .000         .000      P
          CARROLL      L      CAR-CAT  138 KV                   .000         .000      P
          CATOCTIN     OP     CARROLL  138 KV    CB             .000         .000      P
14360    CARROLL-TANEYTOW-GERMANTO (APS)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GERMANTO     OP     B1       115 KV    CB             .000         .000       
          TANEYTOW     OP     GERMANTO 138 KV    DIS            .000         .000       
          TANEYTOW     LD     T1       138 KV                   .000         .000       
          TANEYTOW     OP     BUSTIE   138 KV    DIS            .000         .000       
          CARROLL      L      CAR-TAN  138 KV                   .000         .000       
          CARROLL      OP     TANEYTOW 138 KV    CB             .000         .000       
          TANEYTOW     OP     CARROLL  138 KV    DIS            .000         .000       
          TANEYTOW     OP     T1 DIS   138 KV    DIS            .000         .000       
          GERMANTO     X      1 BANK   138 KV                   .000         .000       
14370    CARROLL-MTAIRY & 230/138 TRAN (APS)               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CARROLL      X      T4       230 KV                   .000         .000      P
          CARROLL      L      CAR-MTA  230 KV                   .000         .000      P
          MTAIRY       OP     CARROL   230 KV    CB             .000         .000      P
          CARROLL      OP     T4 CB    138 KV    CB             .000         .000      P
14380    CATOCTIN-RINGGOLD (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RINGGOLD     OP     CATOCTIN 138 KV    CB             .000         .000      P
          CATOCTIN     L      CAT-RIN  138 KV                   .000         .000      P
          CATOCTIN     OP     RINGGOLD 138 KV    CB             .000         .000      P
14390    CATOCTIN-WALKERSV-MONOCACY (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WALKERSV     LD     T1       138 KV                   .000         .000      P
          WALKERSV     LD     T2       138 KV                   .000         .000      P
          MONOCACY     OP     WALKERSV 138 KV    CB             .000         .000      P
          WALKERSV     OP     CATOCTIN 138 KV    DIS            .000         .000      P
          WALKERSV     OP     MONOCACY 138 KV    DIS            .000         .000      P
          WALKERSV     OP     T1 DIS   138 KV    DIS            .000         .000      P
          MONOCACY     L      MON-WAL  138 KV                   .000         .000      P
          CATOCTIN     L      CAT-WAL  138 KV                   .000         .000      P
          CATOCTIN     OP     WALKERSV 138 KV    CB             .000         .000      P
          WALKERSV     OP     T2 DIS   138 KV    DIS            .000         .000      P
14400    CECI APS-CROSSGAT-PETERS (APS)                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CROSSGAT     OP     T62 DIS  138 KV    DIS            .000         .000      P
          CECI APS     L      CEC-CRO  138 KV                   .000         .000      P
          CROSSGAT     LD     T61      138 KV                   .000         .000      P
          PETERS       L      CRO-PET  138 KV                   .000         .000      P
          CECI APS     OP     CROSSGAT 138 KV    CB             .000         .000      P
          CROSSGAT     OP     PETERS   138 KV    DIS            .000         .000      P
          PETERS       OP     CROSSGAT 138 KV    CB             .000         .000      P
          CROSSGAT     OP     BUS TIE  138 KV    DIS            .000         .000      P
          CROSSGAT     LD     T62      138 KV                   .000         .000      P
          CROSSGAT     OP     CECIL    138 KV    DIS            .000         .000      P
          CROSSGAT     OP     T61 DIS  138 KV    DIS            .000         .000      P
14410    CECI APS-ENLOW (APS)                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CECI APS     OP     ENLOW    138 KV    CB             .000         .000      P
          ENLOW        L      CEC-ENL  138 KV                   .000         .000      P
          ENLOW        OP     CECIL    138 KV    DIS            .000         .000      P
14420    CHARLERO-MITCHELL (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MITCHELL     L      CHA-MIT  138 KV                   .000         .000      P
          MITCHELL     OP     CHARLERO 138 KV    CB             .000         .000      P
          CHARLERO     OP     MITCHELL 138 KV    CB             .000         .000      P
14430    CHARLERO-DRYRUN-MITCHELL (APS)                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MITCHELL     L      DRY-MIT  138 KV                   .000         .000      P
          DRYRUN       OP     MITCHELL 138 KV    DIS            .000         .000      P
          DRYRUN       LD     T61      138 KV                   .000         .000      P
          MITCHELL     OP     DRYRUN   138 KV    CB             .000         .000      P
          CHARLERO     OP     DRYRUN   138 KV    CB             .000         .000      P
          CHARLERO     L      CHA-DRY  138 KV                   .000         .000      P
          DRYRUN       OP     CHARLERO 138 KV    DIS            .000         .000      P
          DRYRUN       OP     T61 DIS  138 KV    DIS            .000         .000      P
          DRYRUN       OP     BUS TIE  138 KV    DIS            .000         .000      P
14440    CHARLERO-BROWNSVILLE JCT -EMERALD-GATEHILL(APS)   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BROWNJCT     L      BRO-EME  138 KV                   .000         .000      P
          BROWNJCT     OP     DUMEMER  138 KV    DIS            .000         .000      P
          GATESHIL     OP     LARDIN   138 KV    CB             .000         .000      P
          BROWNJCT     L      BRO-GAT  138 KV                   .000         .000      P
          CHARLERO     OP     EMERALD  138 KV    CB             .000         .000      P
          BROWNJCT     OP     DUMCHAR  138 KV    DIS            .000         .000      P
          BROWNJCT     L      BRO-CHA  138 KV                   .000         .000      P
          EMERALD      OP     BROWNS   138 KV    DIS            .000         .000      P
          GATESHIL     OP     T1 DIS   138 KV    DIS            .000         .000      P
          BROWNJCT     OP     DUMGATE  138 KV    DIS            .000         .000      P
          EMERALD      OP     BUS TIE  138 KV    CB             .000         .000      P
14450    CHARLERO-GORDON (APS)                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GORDON       OP     CHARLERO 138 KV    CB             .000         .000       
          GORDON       L      CHA-GOR  138 KV                   .000         .000       
          CHARLERO     OP     GORDON   138 KV    CB             .000         .000       
14460    CHARLERO-UNIONJCT-MITCHEL-PETERS (APS)            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          UNIONJCT     OP     MITCHELL 138 KV    DIS            .000         .000      P
          CHARLERO     OP     UNIONJCT 138 KV    CB             .000         .000      P
          PETERS       OP     UNIONJCT 138 KV    CB             .000         .000      P
          CHARLERO     L      CHA-UNI  138 KV                   .000         .000      P
          MITCHELL     OP     UNIONJCT 138 KV    CB             .000         .000      P
          PETERS       L      PET-UNI  138 KV                   .000         .000      P
          UNIONJCT     OP     DUMPET   138 KV    DIS            .000         .000      P
          UNIONJCT     OP     CHARLERO 138 KV    DIS            .000         .000      P
          MITCHELL     L      MIT-UNI  138 KV                   .000         .000      P
14470    CHARLERO-VANCEVIL-WASH APS (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WASH APS     L      VAN-WAS  138 KV                   .000         .000      P
          CHARLERO     L      CHA-VAN  138 KV                   .000         .000      P
          VANCEVIL     OP     DUMCHA   138 KV    DIS            .000         .000      P
          CHARLERO     OP     VANCEVIL 138 KV    CB             .000         .000      P
          WASH APS     OP     VANCEVIL 138 KV    CB             .000         .000      P
          VANCEVIL     OP     DUMWAS   138 KV    DIS            .000         .000      P
          VANCEVIL     LD     T2       138 KV                   .000         .000      P
          VANCEVIL     OP     T2 DIS   138 KV    DIS            .000         .000      P
14480    GORDON-LAGONDA-WIND APS (APS)                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GORDON       L      GOR-LAG  138 KV                   .000         .000      P
          LAGONDA      OP     BUS TIE  138 KV    DIS            .000         .000      P
          WIND APS     OP     LAGONDA  138 KV    CB             .000         .000      P
          LAGONDA      OP     WINDSOR  138 KV    DIS            .000         .000      P
          WIND APS     L      LAG-WIN  138 KV                   .000         .000      P
          LAGONDA      OP     GORDON   138 KV    DIS            .000         .000      P
          LAGONDA      LD     T61      138 KV                   .000         .000      P
          LAGONDA      OP     T61 DIS  138 KV    DIS            .000         .000      P
          LAGONDA      OP     T62 DIS  138 KV    DIS            .000         .000      P
          GORDON       OP     LAGONDA  138 KV    CB             .000         .000      P
          LAGONDA      LD     T62      138 KV                   .000         .000      P
14490    GORDON-LAGONDA-WINDSOR (APS)                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LAGONDA      LD     T61      138 KV                   .000         .000      P
          LAGONDA      LD     T62      138 KV                   .000         .000      P
          GORDON       L      GOR-LAG  138 KV                   .000         .000      P
          LAGONDA      L      LAG-WIN  138 KV                   .000         .000      P
14500    CHARLERO-WESTRAVE-YUKON (APS)                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WESTRAVE     OP     T62 DIS  138 KV    DIS            .000         .000       
          WESTRAVE     LD     T61      138 KV                   .000         .000       
          WESTRAVE     LD     T62      138 KV                   .000         .000       
          WESTRAVE     L      WES-YUK  138 KV                   .000         .000       
          WESTRAVE     OP     BUS TIE  138 KV    DIS            .000         .000       
          CHARLERO     OP     WESTRAVE 138 KV    CB             .000         .000       
          YUKON        OP     Y19      138 KV    CB             .000         .000       
          WESTRAVE     L      CHA-WES  138 KV                   .000         .000       
          WESTRAVE     OP     T61 DIS  138 KV    DIS            .000         .000       
          WESTRAVE     OP     YUKON    138 KV    DIS            .000         .000       
          WESTRAVE     OP     CHARLERO 138 KV    DIS            .000         .000       
          YUKON        OP     Y18      138 KV    CB             .000         .000       
14510    CHARLERO-YUKON (APS)                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          YUKON        OP     Y11      138 KV    CB             .000         .000      P
          CHARLERO     L      CHA-YUK  138 KV                   .000         .000      P
          YUKON        OP     Y10      138 KV    CB             .000         .000      P
          CHARLERO     OP     YUKON    138 KV    CB             .000         .000      P
14520    CHERRYRN-WARFORDS-MCCONNEL (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MCCONNEL     OP     WARFORDS 138 KV    CB             .000         .000       
          CHERRYRN     OP     WARFORDS 138 KV    CB             .000         .000       
          WARFORDS     OP     MCCONNEL 138 KV    DIS            .000         .000       
          WARFORDS     OP     CHERRYRU 138 KV    DIS            .000         .000       
          MCCONNEL     L      MCC-WAR  138 KV                   .000         .000       
          WARFORDS     OP     T2 DIS   138 KV    DIS            .000         .000       
          WARFORDS     LD     T2       138 KV                   .000         .000       
          CHERRYRN     L      CHE-WAR  138 KV                   .000         .000       
          WARFORDS     OP     BUS TIE  138 KV    DIS            .000         .000       
14530    CHERRYRN-MORGAN (APS)                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CHERRYRN     L      CHE-MOR  138 KV                   .000         .000      P
          CHERRYRN     OP     MORGAN   138 KV    CB             .000         .000      P
          MORGAN       OP     CHERRYRN 138 KV    DIS            .000         .000      P
14540    EVERSON-CHESAPEA-RIVESVIL (APS)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EVERSON      OP     CHESAPEA 138 KV    CB             .000         .000      P
          EVERSON      L      CHE-EVE  138 KV                   .000         .000      P
          RIVESVIL     L      CHE-RIV  138 KV                   .000         .000      P
          CHESAPEA     OP     EVERSON  138 KV    DIS            .000         .000      P
          RIVESVIL     OP     CHESAPEA 138 KV    CB             .000         .000      P
          CHESAPEA     OP     RIVESVIL 138 KV    DIS            .000         .000      P
          CHESAPEA     OP     BUSTIE   138 KV    DIS            .000         .000      P
          CHESAPEA     OP     T2 DIS   138 KV    DIS            .000         .000      P
          CHESAPEA     LD     T2       138 KV                   .000         .000      P
14550    WASH APS-CLAYSVIL-DUTCHFOR-ENON-WIND APS (APS)    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CLAYSVIL     OP     WASHINGT 138 KV    DIS            .000         .000      P
          WIND APS     OP     DUTCHFOR 138 KV    CB             .000         .000      P
          WIND APS     L      DUT-WIN  138 KV                   .000         .000      P
          CLAYSVIL     OP     T61 DIS  138 KV    DIS            .000         .000      P
          CLAYSVIL     L      CLA-DUT  138 KV                   .000         .000      P
          DUTCHFOR     OP     WIND APS 138 KV    DIS            .000         .000      P
          DUTCHFOR     OP     CLAYSVCB 138 KV    CB             .000         .000      P
          CLAYSVIL     OP     DUTCHFOR 138 KV    DIS            .000         .000      P
          WASH APS     OP     CLAYSVIL 138 KV    CB             .000         .000      P
          CLAYSVIL     L      CLA-WAS  138 KV                   .000         .000      P
          CLAYSVIL     LD     T61      138 KV                   .000         .000      P
14560    CONNELSV-STONEJCT-KINGFARM-IRONBRID (APS)         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STONEJCT     L      IRO-STO  138 KV                   .000         .000      P
          STONEJCT     L      CON-STO  138 KV                   .000         .000      P
          STONEJCT     OP     KINGFARM 138 KV    DIS            .000         .000      P
          IRONBRID     OP     STONEJCT 138 KV    CB             .000         .000      P
          STONEJCT     L      KIN-STO  138 KV                   .000         .000      P
          STONEJCT     OP     CONNELLS 138 KV    DIS            .000         .000      P
          STONEJCT     OP     DUMIRO   138 KV    DIS            .000         .000      P
          KINGFARM     OP     STONEJCT 138 KV    DIS            .000         .000      P
          CONNELSV     OP     STONEJCT 138 KV    CB             .000         .000      P
14570    L138.Corner-Layman-WolfCreek.86                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CORNER       OP     G        138 KV    CB             .000         .000      P
          WOLFCREE     OP     N        138 KV    CB             .000         .000      P
          LAYMAN       OP     T1 DIS   138 KV    DIS            .000         .000      P
          LAYMAN       LD     T1       138 KV                   .000         .000      P
          LAYMAN       OP     CORNER   138 KV    DIS            .000         .000      P
          LAYMAN       OP     BUS TIE  138 KV    DIS            .000         .000      P
          LAYMAN       OP     WOLFCREE 138 KV    DIS            .000         .000      P
          CORNER       L      COR-LAY  138 KV                   .000         .000      P
          WOLFCREE     L      LAY-WOL  138 KV                   .000         .000      P
14580    L138.Corner-RiverView                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RIVERVIE     OP     1048MOAB 138 KV    DIS            .000         .000      P
          RIVERVIE     OP     646      138 KV    CB             .000         .000      P
          CORNER       L      COR-RIV  138 KV                   .000         .000      P
          CORNER       OP     H        138 KV    CB             .000         .000      P
14590    L138.Corner-Washington2                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CORNER       OP     WASHIRES 138 KV    DIS            .000         .000      P
          CORNER       OP     L        138 KV    CB             .000         .000      P
          WASH2APS     OP     CORNER   138 KV    CB             .000         .000      P
          CORNER       L      COR-WAS  138 KV                   .000         .000      P
          WASH2APS     OP     CORNERES 138 KV    DIS            .000         .000      P
14600    CRUPPERN-CRAIGSVI-POWELLMT (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CRAIGSVI     OP     CRUPPERN 138 KV    DIS            .000         .000      P
          CRAIGSVI     OP     T1 DIS   138 KV    DIS            .000         .000      P
          CRUPPERN     L      CRA-CRU  138 KV                   .000         .000      P
          CRAIGSVI     OP     BUSTIE   138 KV    DIS            .000         .000      P
          CRAIGSVI     LD     T1       138 KV                   .000         .000      P
          POWELLMT     OP     CRAIGSVI 138 KV    CB             .000         .000      P
          CRUPPERN     OP     CRAIGSVI 138 KV    CB             .000         .000      P
          CRAIGSVI     OP     POWELLMO 138 KV    DIS            .000         .000      P
          POWELLMT     L      CRA-POW  138 KV                   .000         .000      P
14610    CRUPPERN-NETTIE-GRASSYFA (APS)                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GRASSYFA     L      GRA-NET  138 KV                   .000         .000      P
          CRUPPERN     L      CRU-NET  138 KV                   .000         .000      P
          NETTIE       OP     DUMGRA   138 KV    DIS            .000         .000      P
          GRASSYFA     OP     NETTIE   138 KV    DIS            .000         .000      P
          NETTIE       LD     T1       138 KV                   .000         .000      P
          CRUPPERN     OP     NETTIE   138 KV    CB             .000         .000      P
          NETTIE       OP     T1 DIS   138 KV    DIS            .000         .000      P
          NETTIE       OP     DUMCRU   138 KV    DIS            .000         .000      P
14620    CUMB APS-RIDGELEY  (APS)                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CUMB APS     OP     RIDGELEY 138 KV    CB             .000         .000      P
          RIDGELEY     L      CUM-RID  138 KV                   .000         .000      P
          RIDGELEY     OP     CUMBERLA 138 KV    CB             .000         .000      P
14640    DAMASCUS-MONTGOME (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MONTGOME     OP     DAMASCUS 230 KV    CB             .000         .000       
          MONTGOME     L      DAM-MON  230 KV                   .000         .000       
          DAMASCUS     OP     MONTGOME 230 KV    DIS            .000         .000       
14650    DAMASCUS-MTAIRY (APS)                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DAMASCUS     OP     MTAIRY   230 KV    DIS            .000         .000      P
          MTAIRY       L      DAM-MTA  230 KV                   .000         .000      P
          MTAIRY       OP     DAMASCUS 230 KV    CB             .000         .000      P
14660    FAIR APS-DENTSRUN-EASTRUN-MARGARET-GLENFALL (APS) Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARSNRES     OP     GLENFALL 138 KV    DIS            .000         .000      P
          MARGARET     L      HAR-MAR2 138 KV                   .000         .000      P
          MARGARET     LD     T1       138 KV                   .000         .000      P
          MARGARET     L      EAS-MAR  138 KV                   .000         .000      P
          MARGARET     OP     HARSNRES 138 KV    DIS            .000         .000      P
          FAIR APS     OP     DENTSRUN 138 KV    CB             .000         .000      P
          EASTRUN      LD     T1       138 KV                   .000         .000      P
          ROBERTS      OP     HARRISON 138 KV    DIS            .000         .000      P
          ROBERTS      OP     T2 DIS   138 KV    DIS            .000         .000      P
          DENTSRUN     OP     FAIRVIEW 138 KV    DIS            .000         .000      P
          HARSNRES     L      HAR-ROB  138 KV                   .000         .000      P
          GLENFALL     L      GLE-HAR  138 KV                   .000         .000      P
          DENTSRUN     L      DEN-EAS  138 KV                   .000         .000      P
          ROBERTS      LD     T2       138 KV                   .000         .000      P
          DENTSRUN     OP     EASTRUN  138 KV    DIS            .000         .000      P
          HARSNRES     OP     DUMMAR   138 KV    DIS            .000         .000      P
          MARGARET     OP     T1 CB    138 KV    CB             .000         .000      P
          MARGARET     OP     EASTRUN  138 KV    DIS            .000         .000      P
          GLENFALL     OP     HARRIRES 138 KV    CB             .000         .000      P
          DENTSRUN     LD     DENTSRUN 138 KV                   .000         .000      P
          HARSNRES     OP     ROBERTS  138 KV    DIS            .000         .000      P
          DENTSRUN     L      DEN-FAI  138 KV                   .000         .000      P
          EASTRUN      OP     DUMDEN   138 KV    DIS            .000         .000      P
          EASTRUN      OP     DUMMAR   138 KV    DIS            .000         .000      P
          DENTSRUN     OP     DENTS CB 138 KV    CB             .000         .000      P
          EASTRUN      OP     T1 DIS   138 KV    DIS            .000         .000      P
14670    L138.DoubleTollGate-Greenwood.DRB-2 (APS)         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DOUBLETO     OP     GREENWOO 138 KV    CB             .000         .000       
          DOUBLETO     L      DOU-GRE  138 KV                   .000         .000       
          GREENWOO     OP     DOUBLETO 138 KV    DIS            .000         .000       
14680    DOUBLETO-MEADOWBR MBG (APS)                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MEADOWBR     OP     MD14     138 KV    CB             .000         .000       
          MEADOWBR     OP     MD15     138 KV    CB             .000         .000       
          DOUBLETO     L      DOU-MEA  138 KV                   .000         .000       
          DOUBLETO     OP     MEADOWB1 138 KV    CB             .000         .000       
14690    DOUBLETO-MEADOWBR MDT (APS)                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MEADOWBR     OP     MD12     138 KV    CB             .000         .000       
          DOUBLETO     OP     MEADOWB2 138 KV    CB             .000         .000       
          DOUBLETO     L      DOU-MEA2 138 KV                   .000         .000       
          MEADOWBR     OP     MD11     138 KV    CB             .000         .000       
14700    L138.DoubleTollGate-OldChapel-Millville           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OLDCHAPE     OP     T1 DIS   138 KV    DIS            .000         .000       
          MILLVILL     OP     OLDCHAPE 138 KV    CB             .000         .000       
          OLDCHAPE     LD     T1       138 KV                   .000         .000       
          OLDCHAPE     LD     T2       138 KV                   .000         .000       
          OLDCHAPE     OP     BUSTIE   138 KV    DIS            .000         .000       
          OLDCHAPE     OP     MILLVILL 138 KV    DIS            .000         .000       
          OLDCHAPE     OP     DOUBLETO 138 KV    DIS            .000         .000       
          DOUBLETO     OP     OLDCHAPE 138 KV    CB             .000         .000       
          OLDCHAPE     OP     T2 DIS   138 KV    DIS            .000         .000       
          OLDCHAPE     L      DOU-OLD  138 KV                   .000         .000       
          OLDCHAPE     L      MIL-OLD  138 KV                   .000         .000       
14710    DOUBLETO-RIVERTON (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RIVERTON     OP     DOUBLETO 138 KV    CB             .000         .000       
          DOUBLETO     L      DOU-RIV  138 KV                   .000         .000       
          DOUBLETO     OP     RIVERTON 138 KV    CB             .000         .000       
14720    L500.Doubs-GooseCreek.514                         Y Y Y S Y Y N N     YNNNNNNNNNNYNNNNNNNNNNYYN YNNNNNNNNNNYNNNNNNNNNNYYN
          DOUBS        OP     543      500 KV    DIS            .000         .000       
          DOUBS        OP     CB 50    500 KV    CB             .000         .000       
          GOOSECRE     OP     514      500 KV    DIS            .000         .000       
          GOOSECRE     OP     51482    500 KV    CB             .000         .000       
          GOOSECRE     OP     514T595  500 KV    CB             .000         .000       
          DOUBS        OP     CB 52    500 KV    CB             .000         .000       
          DOUBS        L      DOU-GOO  500 KV                   .000         .000       
14730    500/230.Doubs.T1&T3 (Sctnlz F)                    Y Y Y S Y Y N N     NNNNNNNNNNYNNNNNNNNNYYNNN NNNNNNNNNNYNNNNNNNNNYYNNN
          DOUBS        X      500-3    500 KV                   .000         .000       
          DOUBS        OP     CB 58    500 KV    CB             .000         .000       
          DOUBS        X      500-1    500 KV                   .000         .000       
          DOUBS        OP     CB 53    500 KV    CB             .000         .000       
          DOUBS        OP     DJ10 CB  230 KV    CB             .000         .000       
          DOUBS        OP     DJ12 CB  230 KV    CB             .000         .000       
          DOUBS        OP     CB 54    500 KV    CB             .000         .000       
14740    500/230.Doubs.T1 (Sctnlz)                         Y Y Y S Y Y N N     YNNNNNNNNNYNNNNNNNNNNNNYN YNNNNNNNNNYNNNNNNNNNNNNYN
          DOUBS        OP     DJ10 CB  230 KV    CB             .000         .000       
          DOUBS        OP     XF1      500 KV    CB             .000         .000       
          DOUBS        X      500-1    500 KV                   .000         .000       
14750    500/230.Doubs.T3 (Sctnlz)                         Y Y Y S Y Y N N     YNNNNNNNNNYNNNNNNNNNNNNYN YNNNNNNNNNYNNNNNNNNNNNNYN
          DOUBS        OP     DJ12 CB  230 KV    CB             .000         .000       
          DOUBS        OP     XF3      500 KV    CB             .000         .000       
          DOUBS        X      500-3    500 KV                   .000         .000       
14760    500/230.Doubs.T2&T4 (Sctnlz F)                    Y Y Y S Y Y N N     NNNNNNNNNNYNNNNNNNNNYYNNN NNNNNNNNNNYNNNNNNNNNYYNNN
          DOUBS        X      500-4    500 KV                   .000         .000       
          DOUBS        OP     DJ11 CB  230 KV    CB             .000         .000       
          DOUBS        OP     CB 55    500 KV    CB             .000         .000       
          DOUBS        OP     CB 57    500 KV    CB             .000         .000       
          DOUBS        X      500-2    500 KV                   .000         .000       
          DOUBS        OP     CB 52    500 KV    CB             .000         .000       
          DOUBS        OP     DJ13 CB  230 KV    CB             .000         .000       
14770    500/230.Doubs.T2 (Sctnlz)                         Y Y Y S Y Y N N     YNNNNNNNNNYNNNNNNNNNNNNYN YNNNNNNNNNYNNNNNNNNNNNNYN
          DOUBS        OP     XF2      500 KV    CB             .000         .000       
          DOUBS        X      500-2    500 KV                   .000         .000       
          DOUBS        OP     DJ13 CB  230 KV    CB             .000         .000       
14780    500/230.Doubs.T4 (Sctnlz)                         Y Y Y S Y Y N N     YNNNNNNNNNYNNNNNNNNNNNNYN YNNNNNNNNNYNNNNNNNNNNNNYN
          DOUBS        X      500-4    500 KV                   .000         .000       
          DOUBS        OP     DJ11 CB  230 KV    CB             .000         .000       
          DOUBS        OP     XF4      500 KV    CB             .000         .000       
14790    DOUBS-LOVETTSV-MILLVILL (APS)                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LOVETTSV     OP     MILLVILL 138 KV    DIS            .000         .000       
          MILLVILL     L      LOV-MIL  138 KV                   .000         .000       
          LOVETTSV     OP     T1 DIS   138 KV    DIS            .000         .000       
          LOVETTSV     OP     DOUBS    138 KV    DIS            .000         .000       
          DOUBS        OP     LOVETTSV 138 KV    CB             .000         .000       
          MILLVILL     OP     LOVETTSV 138 KV    CB             .000         .000       
          DOUBS        L      DOU-LOV  138 KV                   .000         .000       
14800    DOUBS-LIMEKILN 231 (APS)                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DOUBS        L      DOU-LIM2 230 KV                   .000         .000       
          DOUBS        OP     DJ14 CB  230 KV    CB             .000         .000       
          DOUBS        OP     DJ15 CB  230 KV    CB             .000         .000       
          LIMEKILN     OP     DOUBS231 230 KV    CB             .000         .000       
14830    DOUBS-LIMEKILN 207 (APS)                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DOUBS        OP     DJ16 CB  230 KV    CB             .000         .000       
          LIMEKILN     OP     DOUBS    230 KV    CB             .000         .000       
          DOUBS        L      DOU-LIM  230 KV                   .000         .000       
          DOUBS        OP     DJ15 CB  230 KV    CB             .000         .000       
14840    DOUBS-MONOCACY 204 (APS)                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DOUBS        OP     DJ3 CB   230 KV    CB             .000         .000       
          MONOCACY     OP     DOUBS    230 KV    CB             .000         .000       
          DOUBS        L      DOU-MON  230 KV                   .000         .000       
          DOUBS        OP     DJ2 CB   230 KV    CB             .000         .000       
14850    L230.Doubs-Frostown-Boonsbor-Ringold.202          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RINGGOLD     OP     FROSTOWN 230 KV    CB             .000         .000       
          FROSTOWN     L      FRO-RIN  230 KV                   .000         .000       
          FROSTOWN     OP     DUMDOU   230 KV    DIS            .000         .000       
          DOUBS        OP     DJ1 CB   230 KV    CB             .000         .000       
          FROSTOWN     L      DOU-FRO  230 KV                   .000         .000       
          DOUBS        OP     DJ6 CB   230 KV    CB             .000         .000       
          BOONSBOR     OP     FROSTOWN 138 KV    CB             .000         .000       
          FROSTOWN     OP     DUMRIN   230 KV    DIS            .000         .000       
          FROSTOWN     OP     DUMBOON  230 KV    DIS            .000         .000       
14860    DOUBS 230/138 #5 (APS)                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          DOUBS        OP     DJ7 CB   230 KV    CB             .000         .000       
          DOUBS        OP     DJ8 CB   230 KV    CB             .000         .000       
          DOUBS        OP     5TX 138  138 KV    CB             .000         .000       
          DOUBS        X      TRAN  5  230 KV                   .000         .000       
14870    DUPONT-LARKMEAD-EDGELAWN (APS)                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LARKMEAD     OP     BUS TIE  138 KV    DIS            .000         .000       
          LARKMEAD     OP     T1 DIS   138 KV    DIS            .000         .000       
          EDGELAWN     OP     LARKMEAD 138 KV    CB             .000         .000       
          LARKMEAD     LD     T1       138 KV                   .000         .000       
          LARKMEAD     OP     EDGELAWN 138 KV    DIS            .000         .000       
          LARKMEAD     OP     DUPONT   138 KV    DIS            .000         .000       
          LARKMEAD     LD     T2       138 KV                   .000         .000       
          LARKMEAD     OP     T2 DIS   138 KV    DIS            .000         .000       
          DUPONT       L      DUP-LAR  138 KV                   .000         .000       
          DUPONT       OP     LARKMEAD 138 KV    CB             .000         .000       
          EDGELAWN     L      EDG-LAR  138 KV                   .000         .000       
14880    DUPONT-GEPLASTI-WASH2 APS (APS)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WASH2APS     OP     GEPLASTI 138 KV    DIS            .000         .000      P
          DUPONT       L      DUP-GEP  138 KV                   .000         .000      P
          GEPLASTI     OP     DUMDUP   138 KV    DIS            .000         .000      P
          GEPLASTI     OP     T1 CB    138 KV    CB             .000         .000      P
          GEPLASTI     OP     DUMWAS   138 KV    DIS            .000         .000      P
          DUPONT       OP     GEPLASTI 138 KV    CB             .000         .000      P
          WASH2APS     L      GEP-WAS  138 KV                   .000         .000      P
          GEPLASTI     LD     T1       138 KV                   .000         .000      P
14890    EAGLEHEA-MONOCACY (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EAGLEHEA     OP     MONOCACY 230 KV    DIS            .000         .000      P
          MONOCACY     OP     EAGLEHEA 230 KV    CB             .000         .000      P
          EAGLEHEA     L      EAG-MON  230 KV                   .000         .000      P
14900    EAGLEHEA-NEWMARKE (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EAGLEHEA     OP     NEWMARKE 230 KV    DIS            .000         .000      P
          NEWMARKE     OP     EAGLEHEA 230 KV    DIS            .000         .000      P
          EAGLEHEA     L      EAG-NEW  230 KV                   .000         .000      P
14910    L138.Edgelawn-GoffRun (APS)                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          EDGELAWN     OP     GOFFRUN  138 KV    CB             .000         .000      P
          EDGELAWN     L      EDG-GOF  138 KV                   .000         .000      P
          GOFFRUN      OP     EDGELAWN 138 KV    CB             .000         .000      P
14920    EDGELAWN-TRISSLER (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          TRISSLER     OP     EDGELAWN 138 KV    CB             .000         .000      P
          EDGELAWN     L      EDG-TRI  138 KV                   .000         .000      P
          EDGELAWN     OP     TRISSLER 138 KV    CB             .000         .000      P
14930    LOYALHAN-EDGEWATE-VASCO-ETHELSPR-SOCIALHA (APS)   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ETHELSPR     OP     VASCO    138 KV    DIS            .000         .000      P
          EDGEWATE     OP     T1 DIS   138 KV    DIS            .000         .000      P
          LOYALHAN     OP     EDGEWATE 138 KV    CB             .000         .000      P
          VASCOTAP     L      SOC-VAS  138 KV                   .000         .000      P
          SOCIALHA     OP     VASCOTAP 138 KV    CB             .000         .000      P
          VASCO        L      ETH-VAS  138 KV                   .000         .000      P
          VASCOTAP     L      EDG-VAS  138 KV                   .000         .000      P
          VASCO        OP     T1 DIS   138 KV    DIS            .000         .000      P
          ETHELSPR     OP     T61 CS   138 KV    DIS            .000         .000      P
          VASCO        OP     DUMVAS   138 KV    DIS            .000         .000      P
          VASCOTAP     OP     DUMSOC   138 KV    DIS            .000         .000      P
          VASCO        LD     T1       138 KV                   .000         .000      P
          ETHELSPR     LD     T61      138 KV                   .000         .000      P
          LOYALHAN     L      EDG-LOY  138 KV                   .000         .000      P
          EDGEWATE     OP     DUMLOY   138 KV    DIS            .000         .000      P
          EDGEWATE     LD     T1       138 KV                   .000         .000      P
          VASCO        OP     DUMETH   138 KV    DIS            .000         .000      P
          EDGEWATE     OP     DUMVAS   138 KV    DIS            .000         .000      P
          VASCOTAP     OP     DUMEDG   138 KV    DIS            .000         .000      P
          VASCOTAP     L      VAS-VAS  138 KV                   .000         .000      P
          VASCOTAP     OP     DUMVAS   138 KV    DIS            .000         .000      P
14940    EHAGERST-RINGGOLD (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RINGGOLD     L      EHA-RIN  138 KV                   .000         .000      P
          RINGGOLD     OP     EASTHAGE 138 KV    CB             .000         .000      P
          EHAGERST     OP     RINGGOLD 138 KV    DIS            .000         .000      P
14950    WHITEHALL JCT-MCALPIN-PRUNTYTOWN 138kV (APS)      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WHITEJCT     OP     DUMPRU   138 KV    DIS            .000         .000      P
          MCALPIN      OP     WHITEJCT 138 KV    CB             .000         .000      P
          PRUNTYTO     OP     P4       138 KV    CB             .000         .000      P
          ELDORA       LD     T2       138 KV                   .000         .000      P
          PRUNTYTO     L      PRU-WHI  138 KV                   .000         .000      P
          ELDORA       L      ELD-WHI  138 KV                   .000         .000      P
          ELDORA       OP     T2 DIS   138 KV    DIS            .000         .000      P
          PRUNTYTO     OP     P5       138 KV    CB             .000         .000      P
          PRUNTYTO     OP     WHITEJCT 138 KV    DIS            .000         .000      P
          ELDORA       OP     BUSTIE   138 KV    CB             .000         .000      P
          ELDORA       OP     WHITEJCT 138 KV    DIS            .000         .000      P
          WHITEJCT     OP     DUMMCA   138 KV    DIS            .000         .000      P
          MCALPIN      L      MCA-WHI  138 KV                   .000         .000      P
          WHITEJCT     OP     DUMELD   138 KV    DIS            .000         .000      P
14960    L138.Elko-RidgeWayAPS                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RIDG APS     OP     ELKO     138 KV    CB             .000         .000      P
          ELKO         OP     RIDGWAY  138 KV    CB             .000         .000      P
          RIDG APS     L      ELK-RID  138 KV                   .000         .000      P
14970    L138.Brookville-SquabHollow                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BROOKVIL     LD     2 TX     138 KV                   .000         .000      P
          BROOKVIL     OP     BSSEC138 138 KV    CB             .000         .000      P
          SQUABHOL     OP     B14      138 KV    CB             .000         .000      P
          BROOKVIL     OP     SQUAB    138 KV    DIS            .000         .000      P
          BROOKVIL     L      BRO-SQU  138 KV                   .000         .000      P
          SQUABHOL     OP     B16      138 KV    CB             .000         .000      P
14980    L230.Elko-Quehanna-Moshannon                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ELKO         OP     QUEHANNA 230 KV    CB             .000         .000      P
          QUEHANNA     OP     MOSHANNO 230 KV    DIS            .000         .000      P
          QUEHANNA     L      MOS-QUE  230 KV                   .000         .000      P
          MOSHANON     OP     B2       230 KV    CB             .000         .000      P
          QUEHANNA     OP     T81 DIS  230 KV    DIS            .000         .000      P
          QUEHANNA     L      ELK-QUE  230 KV                   .000         .000      P
          MOSHANON     OP     B3       230 KV    CB             .000         .000      P
          QUEHANNA     LD     T81      230 KV                   .000         .000      P
          QUEHANNA     OP     ELKO     230 KV    DIS            .000         .000      P
14990    230/138.Elko.T1                                   Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNNYN YNNYNNNNNNNNNNNNNNNNNNNYN
          ELKO         OP     T1 DIS   230 KV    DIS            .000         .000      P
          ELKO         OP     BUSTIE   230 KV    CB             .000         .000      P
          ELKO         OP     T1 CB    138 KV    CB             .000         .000      P
          ELKO         L      ELK-SQU1 230 KV                   .000         .000      P
          ELKO         OP     FOREST   230 KV    CB             .000         .000      P
          ELKO         X      TRAN  1  230 KV                   .000         .000      P
15000    L138.NFAYETTE-ENLOW (APS)                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NFAYETTE     OP     ENLOW    138 KV    DIS            .000         .000      P
          NFAYETTE     OP     T62 DIS  138 KV    DIS            .000         .000      P
          ENLOW        L      ENL-NFA  138 KV                   .000         .000      P
          NFAYETTE     LD     T62      138 KV                   .000         .000      P
          ENLOW        OP     N FAYETT 138 KV    DIS            .000         .000      P
          NFAYETTE     OP     BUS TIE  138 KV    DIS            .000         .000      P
          ENLOW        OP     T61 CB   138 KV    CB             .000         .000      P
          ENLOW        OP     BUS TIE  138 KV    CB             .000         .000      P
          ENLOW        LD     T61      138 KV                   .000         .000      P
15010    GILBOA-ENONTP-SUMMERSV-POWELLMT-GRASSYFA (APS)    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ENONTP       OP     DUMSUM   138 KV    DIS            .000         .000      P
          GILB APS     OP     ENONTP   138 KV    CB             .000         .000      P
          SUMMERSV     OP     T1 DIS   138 KV    DIS            .000         .000      P
          ENONTP       L      ENO-SUM  138 KV                   .000         .000      P
          SUMMERSV     OP     BUSTIE   138 KV    DIS            .000         .000      P
          ENONTP       OP     DUMGIL   138 KV    DIS            .000         .000      P
          SUMMERSV     OP     GRASSYFA 138 KV    DIS            .000         .000      P
          ENONTP       L      ENO-GIL  138 KV                   .000         .000      P
          SUMMERSV     OP     ENONTAP  138 KV    DIS            .000         .000      P
          SUMMERSV     OP     T2 DIS   138 KV    DIS            .000         .000      P
          ENONTP       OP     DUMPOW   138 KV    DIS            .000         .000      P
          SUMMERSV     LD     T1       138 KV                   .000         .000      P
          GRASSYFA     L      GRA-SUM  138 KV                   .000         .000      P
          SUMMERSV     LD     T2       138 KV                   .000         .000      P
          POWELLMT     OP     ENONTAP  138 KV    CB             .000         .000      P
          ENONTP       L      ENO-POW  138 KV                   .000         .000      P
          GRASSYFA     OP     SUMMERSV 138 KV    DIS            .000         .000      P
15020    L138.Gilboa-Belva-Carbondale-KanawhaRiv           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BELVAAEP     LD     T1A      138 KV                   .000         .000       
          GILB APS     OP     JONESTAP 138 KV    CB             .000         .000       
          CARBOND2     X      1-P      138 KV                   .000         .000       
          JONESTAP     L      BEL-JON  138 KV                   .000         .000       
          BELVAAEP     LD     T1B      138 KV                   .000         .000       
          CARBOND2     OP     B        46 KV     CB             .000         .000       
          CARBOND2     X      1-T      46 KV                    .000         .000       
          KANAWHAR     OP     P        138 KV    CB             .000         .000       
          CARBOND2     OP     E        69 KV     CB             .000         .000       
          GILB APS     L      GIL-JON  138 KV                   .000         .000       
          JONESTAP     OP     JONESDIS 138 KV    DIS            .000         .000       
          CARBOND2     L      CAR-KAN1 138 KV                   .000         .000       
          BELVAAEP     L      BEL-CAR1 138 KV                   .000         .000       
          JONESTAP     LD     JONES    138 KV                   .000         .000       
          CARBOND2     X      1-S      69 KV                    .000         .000       
15030    WWAYNESB-EWAYNESB-RINGGOLD (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WWAYNESB     L      EWA-WWA  138 KV                   .000         .000       
          EWAYNESB     LD     T61      138 KV                   .000         .000       
          EWAYNESB     OP     RINGGOLD 138 KV    DIS            .000         .000       
          WWAYNESB     OP     E WAYNES 138 KV    CB             .000         .000       
          EWAYNESB     OP     T62 DIS  138 KV    DIS            .000         .000       
          EWAYNESB     OP     T61 DIS  138 KV    DIS            .000         .000       
          EWAYNESB     OP     W WAYNES 138 KV    DIS            .000         .000       
          EWAYNESB     OP     BUS TIE  138 KV    DIS            .000         .000       
          RINGGOLD     L      EWA-RIN  138 KV                   .000         .000       
          EWAYNESB     LD     T62      138 KV                   .000         .000       
          RINGGOLD     OP     EASTWAYN 138 KV    CB             .000         .000       
15050    FAIR APS-GRANTOW-RIVESVIL (APS)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GRANTTOW     OP     GEN DIS  18 KV     DIS            .000         .000      P
          GRANTTOW     OP     SS DIS   18 KV     DIS            .000         .000      P
          GRANTTOW     OP     FAIRVIEW 138 KV    DIS            .000         .000      P
          GRANTTOW     LD     SS LOAD  18 KV                    .000         .000      P
          GRANTTOW     OP     NUG CB   138 KV    CB             .000         .000      P
          GRANTTOW     L      FAI-GRA  138 KV                   .000         .000      P
          FAIR APS     OP     GRANTTOW 138 KV    CB             .000         .000      P
          GRANTTOW     OP     RIVESVIL 138 KV    DIS            .000         .000      P
          GRANTTOW     U      ABPP NUG 18 KV                    .000         .000      P
          GRANTTOW     X      GSU WF1  138 KV                   .000         .000      P
          RIVESVIL     OP     GRANTTOW 138 KV    CB             .000         .000      P
          GRANTTOW     L      GRA-RIV  138 KV                   .000         .000      P
15060    FAWN-GOBAIN (APS)                                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GOBAIN       OP     FAWN     138 KV    DIS            .000         .000       
          FAWN         OP     GOBAIN   138 KV    DIS            .000         .000       
          FAWN         L      FAW-GOB  138 KV                   .000         .000       
15070    GRANDPT-FAYETTEV-WWAYNESB (APS)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FAYETTEV     LD     T61      138 KV                   .000         .000       
          FAYETTEV     L      FAY-WWA  138 KV                   .000         .000       
          FAYETTEV     OP     BUS TIE  138 KV    DIS            .000         .000       
          FAYETTEV     OP     GRANDPOI 138 KV    DIS            .000         .000       
          FAYETTEV     LD     T62      138 KV                   .000         .000       
          FAYETTEV     OP     W WAYNES 138 KV    DIS            .000         .000       
          WWAYNESB     OP     FAYETTEV 138 KV    CB             .000         .000       
          FAYETTEV     L      FAY-GRA  138 KV                   .000         .000       
          GRANDPT      OP     FAYETTEV 138 KV    CB             .000         .000       
          FAYETTEV     OP     T62 DIS  138 KV    DIS            .000         .000       
          FAYETTEV     OP     T61 DIS  138 KV    DIS            .000         .000       
15080    MILLVILL-FEAGANSM-STONEWAL (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FEAGANSM     L      FEA-MIL  138 KV                   .000         .000       
          STONEWAL     OP     FEAGANSM 138 KV    CB             .000         .000       
          MILLVILL     OP     FEAGANSM 138 KV    CB             .000         .000       
          FEAGANSM     LD     T1       138 KV                   .000         .000       
          FEAGANSM     OP     BUSTIE   138 KV    DIS            .000         .000       
          FEAGANSM     OP     STONEWAL 138 KV    DIS            .000         .000       
          FEAGANSM     OP     MILLVILL 138 KV    DIS            .000         .000       
          FEAGANSM     L      FEA-STO  138 KV                   .000         .000       
15090    FRAN APS-WASH APS (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FRAN APS     OP     WASHINGT 138 KV    DIS            .000         .000       
          WASH APS     L      FRA-WAS  138 KV                   .000         .000       
15100    L138.Pursley-Whiteley                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PURSLEY      L      PUR-WHI  138 KV                   .000         .000       
          PURSLEY      OP     WHITELEY 138 KV    CB             .000         .000       
          WHITELEY     OP     PURS CB  138 KV    CB             .000         .000       
15110    FREDERICK-MCCAIN 233 line (APS)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MCCAIN       OP     FREDRICK 230 KV    CB             .000         .000       
          FREDERIC     L      FRE-MCC1 230 KV                   .000         .000       
          FREDERIC     OP     BUSTIEA  230 KV    CB             .000         .000       
15120    FREDERICK-MONOCACY 234 line (APS)                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FREDERIC     OP     T5CB     230 KV    CB             .000         .000       
          FREDERIC     L      FRE-MONO 230 KV                   .000         .000       
          MONOCACY     OP     FREDERIK 230 KV    CB             .000         .000       
          FREDERIC     OP     BUSTIEA  230 KV    CB             .000         .000       
          FREDERIC     OP     T2CB     230 KV    CB             .000         .000       
15130    FRENCHCR-HEATERS-SUTTON (APS)                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HEATERS      OP     FRENCHCR 138 KV    DIS            .000         .000       
          HEATERS      OP     T1 DIS   138 KV    DIS            .000         .000       
          HEATERS      LD     T1       138 KV                   .000         .000       
          HEATERS      OP     SUTTON   138 KV    DIS            .000         .000       
          FRENCHCR     L      FRE-HEA  138 KV                   .000         .000       
          SUTTON       L      HEA-SUT  138 KV                   .000         .000       
          SUTTON       OP     HEATRSCB 138 KV    CB             .000         .000       
          FRENCHCR     OP     HEATERS  138 KV    CB             .000         .000       
15140    FRENCHCR-PICKENS (APS)                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FRENCHCR     L      FRE-PIC  138 KV                   .000         .000       
          PICKENS      OP     FRENCHCR 138 KV    CB             .000         .000       
          FRENCHCR     OP     PICKENS  138 KV    CB             .000         .000       
15150    FRENCHSM-JUNCTION (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JUNCTION     L      FRE-JUN  138 KV                   .000         .000      P
          JUNCTION     OP     FRENCHSM 138 KV    CB             .000         .000      P
          FRENCHSM     OP     1321     138 KV    DIS            .000         .000      P
15160    FRENCHSM-HAMPSHIR-RIDGELEY (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RIDGELEY     L      HAM-RID  138 KV                   .000         .000       
          HAMPSHIR     OP     JST2-RC1 138 KV    DIS            .000         .000       
          FRENCHSM     L      FRE-HAM  138 KV                   .000         .000       
          FRENCHSM     OP     1322     138 KV    DIS            .000         .000       
          RIDGELEY     OP     HAMPSHIR 138 KV    CB             .000         .000       
15180    FTMARTIN GEN  1   (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FTMARTIN     OP     FL1 CB   500 KV    CB             .000         .000      P
          FTMARTIN     U      GEN  1   22 KV                    .000         .000      P
          FTMARTIN     X      TRAN  1  500 KV                   .000         .000      P
          FTMARTIN     LD     SS1 LOAD 22 KV                    .000         .000      P
          FTMARTIN     OP     FL2 CB   500 KV    CB             .000         .000      P
15190    FTMARTIN GEN  2   (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          FTMARTIN     OP     FL3 CB   500 KV    CB             .000         .000      P
          FTMARTIN     LD     SS2 LOAD 22 KV                    .000         .000      P
          FTMARTIN     U      GEN  2   22 KV                    .000         .000      P
          FTMARTIN     OP     FL5 CB   500 KV    CB             .000         .000      P
          FTMARTIN     X      TRAN  2  500 KV                   .000         .000      P
15200    L500.NorthLongview-FtMartin                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          NLONGVW      OP     NLVL3    500 KV    CB             .000         .000      P
          FTMARTIN     OP     FL7 CB   500 KV    CB             .000         .000      P
          FTMARTIN     OP     FL8 CB   500 KV    CB             .000         .000      P
          FTMARTIN     L      FTM-NLO  500 KV                   .000         .000      P
          NLONGVW      OP     NLVL2    500 KV    CB             .000         .000      P
          FTMARTIN     OP     NLONGVW  500 KV    DIS            .000         .000      P
15210    L500.FtMartin-Pruntytown.508                      Y Y Y S Y Y N N     YNNNNYNNNNNNNNNNYNNNNNYYN YNNNNYNNNNNNNNNNYNNNNNYYN
          PRUNTYTO     OP     PL1 CB   500 KV    CB             .000         .000       
          PRUNTYTO     OP     PL2 CB   500 KV    CB             .000         .000       
          FTMARTIN     OP     FL8 CB   500 KV    CB             .000         .000       
          PRUNTYTO     L      FTM-PRU  500 KV                   .000         .000       
          FTMARTIN     OP     PRUNTYTO 500 KV    DIS            .000         .000       
          PRUNTYTO     OP     FTMARTIN 500 KV    CB             .000         .000       
          FTMARTIN     OP     FL9 CB   500 KV    CB             .000         .000       
15220    L500.Hatfield-Ronco                               Y Y Y S Y Y N N     YNNNNNYNNNNYNNNNYNNNNNYYN YNNNNNYNNNNYNNNNYNNNNNYYN
          RONCO        OP     DUMHAT   500 KV    DIS            .000         .000      P
          HATFIELD     OP     HFL8 CB  500 KV    CB             .000         .000      P
          HATFIELD     OP     RONCO    500 KV    DIS            .000         .000      P
          RONCO        OP     RCL-1    500 KV    CB             .000         .000      P
          RONCO        OP     RCL-2    500 KV    CB             .000         .000      P
          HATFIELD     L      HAT-RON  500 KV                   .000         .000      P
          HATFIELD     OP     HFL9 CB  500 KV    CB             .000         .000      P
15230    L500.FtMartin-Ronco                               Y Y Y S Y Y N N     YNNNNNYNNNNYNNNNYNNNNNYYN YNNNNNYNNNNYNNNNYNNNNNYYN
          FTMARTIN     OP     RONCO    500 KV    DIS            .000         .000      P
          FTMARTIN     L      FTM-RON  500 KV                   .000         .000      P
          RONCO        OP     DUMFTM   500 KV    DIS            .000         .000      P
          RONCO        OP     RCL-3    500 KV    CB             .000         .000      P
          RONCO        OP     RCL-1    500 KV    CB             .000         .000      P
          FTMARTIN     OP     FL3 CB   500 KV    CB             .000         .000      P
          FTMARTIN     OP     FL4 CB   500 KV    CB             .000         .000      P
15240    LARDIN-GATES HILL (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LARDIN       OP     L-1      138 KV    CB             .000         .000      P
          GATESHIL     L      GAT-LAR  138 KV                   .000         .000      P
          GATESHIL     OP     LARDIN   138 KV    CB             .000         .000      P
          LARDIN       OP     L-4      138 KV    CB             .000         .000      P
15250    HATFIELD RESERVE - LARDIN (APS)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HATFIRES     L      HATR-LAR 138 KV                   .000         .000       
          LARDIN       OP     L-1      138 KV    CB             .000         .000       
          LARDIN       OP     L-2      138 KV    CB             .000         .000       
          LARDIN       OP     HATFIRES 138 KV    DIS            .000         .000       
15260    L138.GlenFalls-OakMound                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GLENFALL     OP     OAKMOUND 138 KV    CB             .000         .000      P
          OAKMOUND     OP     GLEN     138 KV    CB             .000         .000      P
          GLENFALL     L      GLE-OAK  138 KV                   .000         .000      P
15270    L500.Freedom-Shickshinny&Freedom.CC(Future)       Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          FREEDOM2     U      UNIT11   24 KV                    .000         .000      P
          SHICKSHI     OP     FRDM E   500 KV    CB             .000         .000      P
          SHICKSHI     OP     FRDM W   500 KV    CB             .000         .000      P
          FREEDOM2     L      FREE-SHI 500 KV                   .000         .000      P
          SHICKSHI     OP     DUM2     500 KV    DIS            .000         .000      P
          FREEDOM2     OP     21ABA    500 KV    CB             .000         .000      P
          FREEDOM2     OP     ABA01    500 KV    DIS            .000         .000      P
          FREEDOM2     OP     11ABA    500 KV    CB             .000         .000      P
          FREEDOM2     U      UNIT21   24 KV                    .000         .000      P
15280    LAMBERTON-MTWOOD-TRISSLER 138KV                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LAMBERTO     OP     MNTWOOD  138 KV    CB             .000         .000      P
          MTWOOD       OP     T1 DIS   138 KV    DIS            .000         .000      P
          MTWOOD       LD     T1       138 KV                   .000         .000      P
          LAMBERTO     L      LAM-MTW  138 KV                   .000         .000      P
          TRISSLER     OP     MOUNTWOO 138 KV    CB             .000         .000      P
          MTWOOD       L      MTW-TRI  138 KV                   .000         .000      P
15290    GLENFALL-MCALPIN (APS)                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GLENFALL     OP     MCALPIN  138 KV    CB             .000         .000      P
          MCALPIN      L      GLE-MCA  138 KV                   .000         .000      P
          MCALPIN      OP     GLENFALL 138 KV    DIS            .000         .000      P
15300    GLENVILL-GRANTSVI-GOFFRUN (APS)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GRANTSVI     OP     BUS TIE  138 KV    DIS            .000         .000      P
          GOFFRUN      L      GOF-GRA  138 KV                   .000         .000      P
          GRANTSVI     OP     GOFFRUN  138 KV    DIS            .000         .000      P
          GRANTSVI     OP     T2 DIS   138 KV    DIS            .000         .000      P
          GRANTSVI     LD     T2       138 KV                   .000         .000      P
          GLENVILL     OP     GRANTSVI 138 KV    DIS            .000         .000      P
          GLENVILL     L      GLE-GRA  138 KV                   .000         .000      P
          GRANTSVI     OP     GLENVILL 138 KV    DIS            .000         .000      P
          GOFFRUN      OP     GRANTSVI 138 KV    CB             .000         .000      P
15310    L138.Glenville-SandyFork-Weston                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SANDFTAP     L      GLE-SAN  138 KV                   .000         .000      P
          WESTON       OP     T2 DIS   138 KV    DIS            .000         .000      P
          WMIL APS     LD     T1       138 KV                   .000         .000      P
          WESTON       OP     SANDFTAP 138 KV    DIS            .000         .000      P
          WESTON       LD     T1       138 KV                   .000         .000      P
          WESTON       OP     BUSTIE   138 KV    CB             .000         .000      P
          WMIL APS     OP     T1 DIS   138 KV    DIS            .000         .000      P
          WESTON       LD     T2       138 KV                   .000         .000      P
          SANDFTAP     L      SAN-WES  138 KV                   .000         .000      P
          WESTON       OP     T1 DIS   138 KV    DIS            .000         .000      P
          SANDFTAP     LD     LOAD 1   138 KV                   .000         .000      P
          GLENVILL     OP     BUS TIE  138 KV    CB             .000         .000      P
          SANDFTAP     OP     LOAD1    138 KV    DIS            .000         .000      P
          GLENVILL     OP     SANFTAP  138 KV    DIS            .000         .000      P
          SANDFTAP     OP     GLENVILL 138 KV    DIS            .000         .000      P
          SANDFTAP     OP     WESTON   138 KV    DIS            .000         .000      P
15320    GOBAIN-PITTSBURGH MILLS (APS)                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GOBAIN       OP     PITT DIS 138 KV    DIS            .000         .000      P
          GOBAIN       L      GOB-PIT  138 KV                   .000         .000      P
          PITTMILL     OP     GOBDIS   138 KV    DIS            .000         .000      P
15330    GOFFRUN-IVYDALE-POWELLMT & CAP1 (APS)             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          POWELLMT     OP     IVYDALE  138 KV    CB             .000         .000      P
          IVYDALE      LD     T1       138 KV                   .000         .000      P
          GOFFRUN      OP     SW-IVYD  138 KV    DIS            .000         .000      P
          IVYDALE      OP     T1 DIS   138 KV    DIS            .000         .000      P
          IVYDALE      OP     GOFFRUN  138 KV    DIS            .000         .000      P
          GOFFRUN      OP     CAP1 CB  138 KV    CB             .000         .000      P
          IVYDALE      OP     POWELLMT 138 KV    DIS            .000         .000      P
          GOFFRUN      L      GOF-IVY  138 KV                   .000         .000      P
          GOFFRUN      CP     CAP1     138 KV                   .000         .000      P
          POWELLMT     L      IVY-POW  138 KV                   .000         .000      P
15340    GORE APS-STONEWAL (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GORE APS     L      GOR-STO  138 KV                   .000         .000      P
          STONEWAL     OP     GORE APS 138 KV    CB             .000         .000      P
          GORE APS     OP     STONEWAL 138 KV    DIS            .000         .000      P
15350    GORE APS-HAMPSHIR-MEADOWBROOK (APS)               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HAMPSHIR     OP     JST3-RC2 138 KV    DIS            .000         .000      P
          MEADOWBR     OP     MD-1     138 KV    CB             .000         .000      P
          GORE APS     OP     HAMPSHIR 138 KV    DIS            .000         .000      P
          MEADOWBR     L      HAM-MEA  138 KV                   .000         .000      P
          GORE APS     L      GOR-HAM  138 KV                   .000         .000      P
          GORE APS     OP     BUSTIE   138 KV    CB             .000         .000      P
          MEADOWBR     OP     MD-2     138 KV    CB             .000         .000      P
15360    Gorsuch.U1 (Retired)                              Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          GORSUCH      OP     GEN DIS  138 KV    DIS            .000         .000      P
          GORSUCH      U      AMP OHIO 138 KV                   .000         .000      P
15370    L138.Gorsuch-HarmarHill-Goodrich-MillCreek        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GORSUCH      OP     BB       138 KV    CB             .000         .000      P
          HARMARHI     OP     GORSUCH  138 KV    DIS            .000         .000      P
          GOODRICH     LD     T1       138 KV                   .000         .000      P
          GORSUCH      L      GOR-HAR  138 KV                   .000         .000      P
          MILL AEP     LD     T2       138 KV                   .000         .000      P
          GOODRICH     OP     T1 CB    138 KV    CB             .000         .000      P
          MILL AEP     LD     T4       138 KV                   .000         .000      P
          GOODRICH     OP     DUMMIL   138 KV    DIS            .000         .000      P
          HARMARHI     LD     T1       138 KV                   .000         .000      P
          HARMARHI     OP     DUMGOO   138 KV    DIS            .000         .000      P
          GOODRICH     L      GOO-HAR  138 KV                   .000         .000      P
          GORSUCH      OP     C        138 KV    CB             .000         .000      P
          GOODRICH     OP     DUMHAR   138 KV    DIS            .000         .000      P
          MILL AEP     OP     BUS TIE  138 KV    CB             .000         .000      P
          HARMARHI     OP     T1 DIS   138 KV    DIS            .000         .000      P
          GOODRICH     L      GOO-MIL  138 KV                   .000         .000      P
          MILL AEP     OP     GOODRICH 138 KV    DIS            .000         .000      P
          GORSUCH      CP     CAPB     138 KV                   .000         .000      P
15380    L138.Gorsuch-Riverview                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GORSUCH      CP     CAPA     138 KV                   .000         .000      P
          GORSUCH      OP     AA       138 KV    CB             .000         .000      P
          GORSUCH      L      GOR-RIV  138 KV                   .000         .000      P
          GORSUCH      OP     C        138 KV    CB             .000         .000      P
          RIVERVIE     OP     644      138 KV    CB             .000         .000      P
15390    GRANDPT-GUILFORD (APS)                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GUILFORD     OP     GRANDPOI 138 KV    CB             .000         .000      P
          GRANDPT      OP     GUILFORD 138 KV    CB             .000         .000      P
          GRANDPT      L      GRA-GUI  138 KV                   .000         .000      P
15400    GUILFORD GEN12                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GUILFORD     U      GEN12    138 KV                   .000         .000      P
15410    GUILFORD GEN13                                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GUILFORD     U      GEN13    138 KV                   .000         .000       
15420    L138.GrassyFalls-McClung                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          GRASSYFA     OP     MCCLUNG  138 KV    DIS            .000         .000      P
          GRASSYFA     L      GRA-MCC  138 KV                   .000         .000      P
          MCCLUNG2     X      1        138 KV                   .000         .000      P
          MCCLUNG2     OP     B        69 KV     CB             .000         .000      P
15430    L138.Guilford-TexasEast6-McConnellsburg           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MCCONNEL     OP     TEXASEA6 138 KV    CB             .000         .000      P
          GUILFORD     OP     TEXASEA6 138 KV    CB             .000         .000      P
          TEXASEA6     OP     T1 DIS   138 KV    DIS            .000         .000      P
          TEXASEA6     OP     MCCONNEL 138 KV    DIS            .000         .000      P
          MCCONNEL     L      MCC-TEX  138 KV                   .000         .000      P
          TEXASEA6     OP     DUMGUI   138 KV    DIS            .000         .000      P
          GUILFORD     L      GUI-TEX  138 KV                   .000         .000      P
          TEXASEA6     LD     T1       138 KV                   .000         .000      P
15440    L138.Halfway-Marlowe                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HALFWAY      LD     T1       138 KV                   .000         .000      P
          HALFWAY      OP     T4 DIS   138 KV    DIS            .000         .000      P
          MARLOWE      OP     HALFWAY  138 KV    CB             .000         .000      P
          HALFWAY      OP     MARLOWE  138 KV    DIS            .000         .000      P
          HALFWAY      OP     AB TIE   138 KV    CB             .000         .000      P
          MARLOWE      L      HAL-MAR  138 KV                   .000         .000      P
15450    L138.Halfway-Paramount                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HALFWAY      OP     PARAMOUN 138 KV    DIS            .000         .000      P
          PARAMOUN     OP     HALFWAY  138 KV    DIS            .000         .000      P
          HALFWAY      L      HAL-PAR  138 KV                   .000         .000      P
          PARAMOUN     OP     T2 CB    138 KV    CB             .000         .000      P
          HALFWAY      OP     T3 DIS   138 KV    DIS            .000         .000      P
          HALFWAY      OP     BC TIE   138 KV    CB             .000         .000      P
          PARAMOUN     OP     BUS_TIE  138 KV    CB             .000         .000      P
15460    L138.Paramount-Reid.RI-2                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PARAMOUN     L      PAR-REI  138 KV                   .000         .000      P
          REID         OP     PARAMOUN 138 KV    CB             .000         .000      P
          PARAMOUN     OP     BUS_TIE  138 KV    CB             .000         .000      P
15470    L138.Hardy-Junction.JUH1                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARDY        OP     BUSTIE   138 KV    CB             .000         .000      P
          HARDY        OP     BAKER1   138 KV    CB             .000         .000      P
          JUNCTION     OP     HARDY    138 KV    CB             .000         .000      P
          HARDY        OP     JUNCTION 138 KV    DIS            .000         .000      P
          BAKER1       L      BAK-HAR  138 KV                   .000         .000      P
          HARDY        OP     T1 DIS   138 KV    DIS            .000         .000      P
          HARDY        L      HAR-JUN  138 KV                   .000         .000      P
          BAKER1       LD     T1       138 KV                   .000         .000      P
15480    L138.Hardy-NorthPetersburg.JUH2                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARDY        CP     CAP2     138 KV                   .000         .000      P
          HARDY        L      HAR-NPE  138 KV                   .000         .000      P
          HARDY        OP     CAP2 CB  138 KV    CB             .000         .000      P
          HARDY        OP     NPETERSB 138 KV    DIS            .000         .000      P
          NPETERSB     OP     HARDY    138 KV    CB             .000         .000      P
          HARDY        LD     T4       138 KV                   .000         .000      P
15490    HARR APS GEN  1   (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARR APS     U      GEN  1   20 KV                    .000         .000      P
          HARR APS     OP     HL1 CB   500 KV    CB             .000         .000      P
          HARR APS     OP     SS1 DIS  20 KV     DIS            .000         .000      P
          HARR APS     OP     HL2 CB   500 KV    CB             .000         .000      P
          HARR APS     X      TRAN  1  500 KV                   .000         .000      P
          HARR APS     LD     SS1 LOAD 20 KV                    .000         .000      P
15500    HARR APS GEN  2   (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARR APS     OP     HL4 CB   500 KV    CB             .000         .000       
          HARR APS     U      GEN  2   20 KV                    .000         .000       
          HARR APS     OP     HL5 CB   500 KV    CB             .000         .000       
          HARR APS     X      TRAN  2  500 KV                   .000         .000       
          HARR APS     LD     SS2 LOAD 20 KV                    .000         .000       
          HARR APS     OP     SS2 DIS  20 KV     DIS            .000         .000       
15510    Harrison.U3 (APS)                                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARR APS     LD     SS3 LOAD 20 KV                    .000         .000      P
          HARR APS     X      TRAN  3  500 KV                   .000         .000      P
          HARR APS     OP     SS3 DIS  20 KV     DIS            .000         .000      P
          HARR APS     OP     HL7 CB   500 KV    CB             .000         .000      P
          HARR APS     OP     HL8 CB   500 KV    CB             .000         .000      P
          HARR APS     U      GEN  3   20 KV                    .000         .000      P
15520    HARR APS-WYLIERID (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          WYLIERID     OP     WL2 CB   500 KV    CB             .000         .000      P
          HARR APS     OP     HL10 CB  500 KV    CB             .000         .000      P
          WYLIERID     L      HAR-WYL  500 KV                   .000         .000      P
          WYLIERID     OP     WL1 CB   500 KV    CB             .000         .000      P
          HARR APS     OP     HL11 CB  500 KV    CB             .000         .000      P
15530    LUXOR-NGREENS-HEMPFIELD-PEN-HARCTY (APS)          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NOAKFORD     OP     A3002    138 KV    DIS            .000         .000      P
          NOAKFORD     L      NOA-PEN  138 KV                   .000         .000      P
          NGREENSB     OP     STOSPJCT 138 KV    DIS            .000         .000      P
          SOAKFORD     OP     T61 DIS  138 KV    DIS            .000         .000      P
          NOAKFORD     LD     T61      138 KV                   .000         .000      P
          STONYJCT     OP     DUMLUX   138 KV    DIS            .000         .000      P
          HARRCITY     L      HAR-PEN  138 KV                   .000         .000      P
          PENN APS     OP     N OAKFOR 138 KV    DIS            .000         .000      P
          NOAKFORD     OP     DUMPEN   138 KV    DIS            .000         .000      P
          STONYJCT     OP     DUMSOU   138 KV    DIS            .000         .000      P
          PENN APS     OP     T61 DIS  138 KV    DIS            .000         .000      P
          NGREENSB     LD     T62      138 KV                   .000         .000      P
          LUXOR        L      LUX-STO  138 KV                   .000         .000      P
          NGREENSB     OP     BUS TIE  138 KV    DIS            .000         .000      P
          NGREENSB     LD     T61      138 KV                   .000         .000      P
          HARRCITY     OP     PENN     138 KV    CB             .000         .000      P
          SOAKFORD     LD     T61      138 KV                   .000         .000      P
          NGREENSB     OP     HEMPFIEL 138 KV    DIS            .000         .000      P
          PENN APS     OP     HARRCITY 138 KV    DIS            .000         .000      P
          NOAKFORD     OP     DUMSOU   138 KV    DIS            .000         .000      P
          STONYJCT     L      NGR-STO  138 KV                   .000         .000      P
          SOAKFORD     OP     DUMNOR   138 KV    DIS            .000         .000      P
          PENN APS     OP     BUS TIE  138 KV    DIS            .000         .000      P
          HEMPFIEL     L      HEM-NGR  138 KV                   .000         .000      P
          STONYJCT     L      SOA-STO  138 KV                   .000         .000      P
          NOAKFORD     L      NOA-SOA  138 KV                   .000         .000      P
          PENN APS     LD     T61      138 KV                   .000         .000      P
          NGREENSB     OP     T62 DIS  138 KV    DIS            .000         .000      P
          NGREENSB     OP     T61 DIS  138 KV    DIS            .000         .000      P
          STONYJCT     OP     DUMNOR   138 KV    DIS            .000         .000      P
          SOAKFORD     OP     DUMSTO   138 KV    DIS            .000         .000      P
15540    HARCTY-WHITEVAL (APS)                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARRCITY     OP     WHITEVAL 138 KV    DIS            .000         .000       
          WHITEVAL     OP     HARRCITY 138 KV    CB             .000         .000       
          HARRCITY     L      HAR-WHI  138 KV                   .000         .000       
15550    HARWICK-HOUSEVIL (APS)                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARWICK      OP     HOUSEVIL 138 KV    DIS            .000         .000      P
          HOUSEVIL     L      HAR-HOU  138 KV                   .000         .000      P
          HOUSEVIL     OP     HARWICK  138 KV    DIS            .000         .000      P
15560    HARWICK-SPRINGDALE (APS)                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HARWICK      L      HAR-SPR  138 KV                   .000         .000       
          SPRINGDA     OP     HARWICK  138 KV    CB             .000         .000       
          HARWICK      OP     SPRINGDA 138 KV    DIS            .000         .000       
15570    L500.Hatfield-RhodesLane.517                      Y Y Y S Y Y N N     YNNNNYYNNNNNNNNNNNNNNNYYN YNNNNYYNNNNNNNNNNNNNNNYYN
          RHODESLN     OP     B1       500 KV    CB             .000         .000       
          HATFIELD     L      HAT-RHO  500 KV                   .000         .000       
          RHODESLN     OP     B3       500 KV    CB             .000         .000       
          HATFIELD     OP     HFL2 CB  500 KV    CB             .000         .000       
          HATFIELD     OP     DUM1     500 KV    DIS            .000         .000       
          HATFIELD     OP     HFL3 CB  500 KV    CB             .000         .000       
          RHODESLN     OP     DUM1     500 KV    DIS            .000         .000       
15580    L500.RhodesLane-WestMoreland & WMorelnd.CC        Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          RHODESLN     OP     B3       500 KV    CB             .000         .000      P
          WMORELND     U      CT1      20 KV                    .000         .000      P
          RHODESLN     L      RHO-WMO  500 KV                   .000         .000      P
          WMORELND     U      CT2      20 KV                    .000         .000      P
          RHODESLN     OP     B2       500 KV    CB             .000         .000      P
          WMORELND     U      STG      20 KV                    .000         .000      P
          RHODESLN     OP     WMORE    500 KV    DIS            .000         .000      P
          WMORELND     OP     RHODES   500 KV    CB             .000         .000      P
15590    HATFIELD GEN  3   (APS)                           Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNN
          HATFIELD     OP     CB 05    18 KV     CB             .000         .000      P
          HATFIELD     X      TRAN  3  500 KV                   .000         .000      P
          HATFIELD     U      GEN  3   18 KV                    .000         .000      P
          HATFIELD     OP     HFL8 CB  500 KV    CB             .000         .000      P
          HATFIELD     LD     SS3 LOAD 18 KV                    .000         .000      P
          HATFIELD     OP     HFL7 CB  500 KV    CB             .000         .000      P
15610    HEMPFIEL-SEWICKLE-WALTZMIL-YUKON (APS)            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SEWICKLE     OP     WALTZMIL 138 KV    DIS            .000         .000       
          SEWICKLE     OP     J-2      138 KV    DIS            .000         .000       
          SEWICKLE     OP     T61 DIS  138 KV    DIS            .000         .000       
          SEWICKLE     OP     HEMPFIEL 138 KV    DIS            .000         .000       
          WALTZMIL     OP     T2 DIS   138 KV    DIS            .000         .000       
          YUKON        OP     Y6       138 KV    CB             .000         .000       
          SEWICKLE     LD     T61      138 KV                   .000         .000       
          WALTZMIL     OP     DUMYUK   138 KV    DIS            .000         .000       
          WALTZMIL     OP     DUMSEW   138 KV    DIS            .000         .000       
          HEMPFIEL     OP     SEWICKLE 138 KV    CB             .000         .000       
          WALTZMIL     LD     T2       138 KV                   .000         .000       
          YUKON        L      WAL-YUK  138 KV                   .000         .000       
          HEMPFIEL     L      HEM-SEW  138 KV                   .000         .000       
          YUKON        OP     Y7       138 KV    CB             .000         .000       
          SEWICKLE     L      SEW-WAL  138 KV                   .000         .000       
15620    HUNTINGD-ROBBINS-YUKON (APS)                      Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          ROBBINS      OP     YUKON    138 KV    DIS            .000         .000      P
          YUKON        OP     Y8       138 KV    CB             .000         .000      P
          ROBBINS      OP     T61 DIS  138 KV    DIS            .000         .000      P
          ROBBINS      LD     T62      138 KV                   .000         .000      P
          YUKON        L      ROB-YUK  138 KV                   .000         .000      P
          HUNTINGD     L      HUN-ROB  138 KV                   .000         .000      P
          HUNTINGD     OP     ROBBINS  138 KV    CB             .000         .000      P
          ROBBINS      OP     HUNTINGD 138 KV    DIS            .000         .000      P
          ROBBINS      OP     T62 DIS  138 KV    DIS            .000         .000      P
          YUKON        OP     Y7       138 KV    CB             .000         .000      P
          ROBBINS      OP     BUS TIE  138 KV    DIS            .000         .000      P
          ROBBINS      LD     T61      138 KV                   .000         .000      P
15630    HUNTINGD-SPRINGDA (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HUNTINGD     OP     SPRINGDA 138 KV    DIS            .000         .000      P
          SPRINGDA     OP     HUNTINGD 138 KV    CB             .000         .000      P
          HUNTINGD     L      HUN-SPR  138 KV                   .000         .000      P
15640    INWOOD-STONEWAL (APS)                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          INWOOD       L      INW-STO  138 KV                   .000         .000       
          INWOOD       OP     STONEWAL 138 KV    DIS            .000         .000       
          STONEWAL     OP     INWOOD   138 KV    CB             .000         .000       
15650    INWOOD-KEARNEYS (APS)                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          INWOOD       OP     KEARNEYS 138 KV    DIS            .000         .000       
          KEARNEYS     OP     BUS TIE  138 KV    CB             .000         .000       
          INWOOD       L      INW-KEA  138 KV                   .000         .000       
15660    OAKG APS-JOHNSJCT-SVIENNA-JOHNSMAN-PARKERSB (APS) Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JOHNSMAN     OP     T1 CB    138 KV    CB             .000         .000      P
          SVIENNA      OP     T1 DIS   138 KV    DIS            .000         .000      P
          OAKG APS     OP     2        138 KV    CB             .000         .000      P
          SVIENNA      LD     T1       138 KV                   .000         .000      P
          JOHNSJCT     OP     DUMPAR   138 KV    DIS            .000         .000      P
          JOHNSJCT     OP     DUMS V   138 KV    DIS            .000         .000      P
          PARKERSB     OP     JOHNSJCT 138 KV    CB             .000         .000      P
          SVIENNA      L      JMA-SVI  138 KV                   .000         .000      P
          JOHNSMAN     LD     T1       138 KV                   .000         .000      P
          SVIENNA      OP     DUMJOH   138 KV    DIS            .000         .000      P
          SVIENNA      L      JOH-SVI  138 KV                   .000         .000      P
          OAKG APS     OP     1        138 KV    CB             .000         .000      P
          OAKG APS     L      JOH-OAK  138 KV                   .000         .000      P
          SVIENNA      OP     DUMJCT   138 KV    DIS            .000         .000      P
          PARKERSB     L      JOH-PAR  138 KV                   .000         .000      P
          JOHNSJCT     OP     DUMOAK   138 KV    DIS            .000         .000      P
15670    PARKERSB-JUGRUN-TRISSLER (APS)                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JUGRUN       LD     T1       138 KV                   .000         .000       
          JUGRUN       OP     DUMTRI   138 KV    DIS            .000         .000       
          PARKERSB     L      JUG-PAR  138 KV                   .000         .000       
          TRISSLER     OP     JUGRUN   138 KV    CB             .000         .000       
          JUGRUN       OP     T1 DIS   138 KV    DIS            .000         .000       
          TRISSLER     L      JUG-TRI  138 KV                   .000         .000       
          JUGRUN       OP     DUMPAR   138 KV    DIS            .000         .000       
          PARKERSB     OP     JUGRUN   138 KV    CB             .000         .000       
15680    JUNCTION-PARRRUN (APS)                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PARRRUN      OP     JUNCTION 138 KV    DIS            .000         .000      P
          JUNCTION     OP     PARRRUN  138 KV    CB             .000         .000      P
          PARRRUN      L      JUN-PAR  138 KV                   .000         .000      P
15690    KEARNEYS-OPEQUON (APS)                            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OPEQUON      OP     KEARNEYS 138 KV    CB             .000         .000      P
          KEARNEYS     OP     OPEQUON  138 KV    DIS            .000         .000      P
          OPEQUON      L      KEA-OPE  138 KV                   .000         .000      P
15700    KEISTERS-KRENDALE (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KEISTERS     OP     KRENDALE 138 KV    DIS            .000         .000      P
          KEISTERS     OP     T62 DIS  138 KV    DIS            .000         .000      P
          KRENDALE     OP     KEISTERS 138 KV    CB             .000         .000      P
          KEISTERS     L      KEI-KRE  138 KV                   .000         .000      P
          KEISTERS     OP     T1 LS CB 25 KV     CB             .000         .000      P
          KEISTERS     LD     T62      138 KV                   .000         .000      P
          KEISTERS     X      T1 XF    138 KV                   .000         .000      P
15710    KEISTERS-CAMPBELL OE 69 KV (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KEISTERS     OP     CAMPBELL 69 KV     DIS            .000         .000       
          CAMPOHED     OP     A_AA2668 69 KV     CB             .000         .000       
          KEISTERS     L      CAM-KEI  69 KV                    .000         .000       
15720    KISKIVAL-VANDERGR (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KISKIVAL     OP     VANDERGR 138 KV    CB             .000         .000      P
          KISKIVAL     L      KIS-VAN  138 KV                   .000         .000      P
          VANDERGR     OP     KISKIVAL 138 KV    DIS            .000         .000      P
15730    KISKIVAL-NWASHING (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NWASHING     OP     T61 DIS  138 KV    DIS            .000         .000      P
          KISKIVAL     L      KIS-NWA  138 KV                   .000         .000      P
          NWASHING     OP     KISKIVAL 138 KV    DIS            .000         .000      P
          NWASHING     LD     T61      138 KV                   .000         .000      P
          KISKIVAL     OP     N WASHIN 138 KV    CB             .000         .000      P
15740    MEADOWBR-KLINESMI-RIVERTON (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MEADOWBR     L      KLI-MEA  138 KV                   .000         .000      P
          KLINESMI     LD     T1       138 KV                   .000         .000      P
          MEADOWBR     OP     MD18     138 KV    CB             .000         .000      P
          RIVERTON     L      KLI-RIV  138 KV                   .000         .000      P
          KLINESMI     OP     RIVERTON 138 KV    DIS            .000         .000      P
          RIVERTON     OP     KLINESMI 138 KV    CB             .000         .000      P
          KLINESMI     OP     T1 DIS   138 KV    DIS            .000         .000      P
          KLINESMI     OP     BUS TIE  138 KV    DIS            .000         .000      P
          MEADOWBR     OP     MD17     138 KV    CB             .000         .000      P
          KLINESMI     OP     MEADOWBR 138 KV    DIS            .000         .000      P
15750    L138.Krendale-Seneca-MarkWest-Maple               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          KRENDALE     L      KRE-SEN  138 KV                   .000         .000      P
          ZELIENOP     L      MAR-ZEL  138 KV                   .000         .000      P
          MAPLEOE      OP     BS1      138 KV    DIS            .000         .000      P
          MAPLEOE      L      MAP-ZEL  138 KV                   .000         .000      P
          SENECAOE     OP     A6101    138 KV    DIS            .000         .000      P
          MARKWEST     OP     B3       138 KV    CB             .000         .000      P
          MARKWEST     L      MAR-MAR3 138 KV                   .000         .000      P
          MAPLEOE      OP     B18      138 KV    CB             .000         .000      P
          MAPLEOE      OP     B10      138 KV    CB             .000         .000      P
          KRENDALE     OP     SENECA   138 KV    DIS            .000         .000      P
          SENECAOE     OP     CS8      138 KV    CB             .000         .000      P
          MARKWEST     L      MAR-SEN  138 KV                   .000         .000      P
15760    LAKELYNN-PIERPONT (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LAKELYNN     L      LAK-PIE  138 KV                   .000         .000       
          PIERPONT     OP     LAKELYNN 138 KV    DIS            .000         .000       
          LAKELYNN     OP     PIERPNT  138 KV    CB             .000         .000       
15770    LAKELYNN-WESTRUN-COLLINS FERRY (APS)              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WESTRUN      OP     LAKELYNN 138 KV    DIS            .000         .000       
          LAKELYNN     OP     W RUN    138 KV    CB             .000         .000       
          WESTRUN      OP     T1 DIS   138 KV    DIS            .000         .000       
          WESTRUN      LD     T2       138 KV                   .000         .000       
          WESTRUN      OP     BUSTIE   138 KV    DIS            .000         .000       
          WESTRUN      LD     T1       138 KV                   .000         .000       
          COLLINSF     L      COL-WES  138 KV                   .000         .000       
          WESTRUN      OP     T2 DIS   138 KV    DIS            .000         .000       
          COLLINSF     OP     WRUN     138 KV    CB             .000         .000       
          LAKELYNN     L      LAK-WES  138 KV                   .000         .000       
15780    COLLINS FERRY-OSAGE (APS)                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          COLLINSF     OP     WRUN     138 KV    CB             .000         .000      P
          OSAGE        OP     COLLINSF 138 KV    CB             .000         .000      P
          COLLINSF     L      COL-OSA  138 KV                   .000         .000      P
          COLLINSF     LD     T2       138 KV                   .000         .000      P
          COLLINSF     LD     T1       138 KV                   .000         .000      P
          COLLINSF     OP     SW-T2    138 KV    DIS            .000         .000      P
          COLLINSF     OP     SW-T1    138 KV    DIS            .000         .000      P
15790    LAKELYNN T1 T2 & GEN  1-4 (APS)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LAKELYNN     X      T1       138 KV                   .000         .000      P
          LAKELYNN     OP     T2 CB    138 KV    CB             .000         .000      P
          LAKELYNN     OP     T1 CB    138 KV    CB             .000         .000      P
          LAKELYNN     X      T2       138 KV                   .000         .000      P
          LAKELYNN     U      GEN  1-4 11 KV                    .000         .000      P
15800    L230.Limekiln-McCain.232                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LIMEKILN     OP     MCCAIN   230 KV    CB             .000         .000       
          LIMEKILN     L      LIM-MCN  230 KV                   .000         .000       
          MCCAIN       OP     LIMEKILN 230 KV    CB             .000         .000       
15810    LONGREAC-PADENCIT (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PADENCIT     OP     LONGREAC 138 KV    DIS            .000         .000      P
          LONGREAC     OP     PADENCIT 138 KV    CB             .000         .000      P
          LONGREAC     L      LON-PAD  138 KV                   .000         .000      P
15820    WEIRTON-MAHANS LANE 138 KV (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WEIRTON      OP     252 CB   138 KV    CB             .000         .000      P
          MAHANSLA     L      MAH-WEI  138 KV                   .000         .000      P
          MAHANSLA     OP     252 CB   138 KV    CB             .000         .000      P
15830    PRUNTYTO-MAPLELAK-QUIETDEL (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          QUIETDEL     L      MAP-QUI  138 KV                   .000         .000      P
          MAPLELAK     OP     QUIETDEL 138 KV    DIS            .000         .000      P
          PRUNTYTO     OP     P19      138 KV    CB             .000         .000      P
          MAPLELAK     LD     T1       138 KV                   .000         .000      P
          QUIETDEL     OP     MAPLELAK 138 KV    CB             .000         .000      P
          MAPLELAK     OP     BUS TIE  138 KV    DIS            .000         .000      P
          PRUNTYTO     L      MAP-PRU  138 KV                   .000         .000      P
          PRUNTYTO     OP     P20      138 KV    CB             .000         .000      P
          MAPLELAK     OP     T1 DIS   138 KV    DIS            .000         .000      P
          MAPLELAK     OP     PRUNTYTO 138 KV    DIS            .000         .000      P
15860    L138.Pricehill-Martinka-Pruntytown                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PRUNTYTO     L      MAR-PRU  138 KV                   .000         .000      P
          PRUNTYTO     OP     P10      138 KV    CB             .000         .000      P
          MARTINKA     LD     T1       138 KV                   .000         .000      P
          MARTINKA     OP     PRUNTYTO 138 KV    DIS            .000         .000      P
          PRUNTYTO     OP     P11      138 KV    CB             .000         .000      P
          MARTINKA     OP     T1 DIS   138 KV    DIS            .000         .000      P
          PRICEHIL     OP     MARTINKA 138 KV    DIS            .000         .000      P
          MARTINKA     OP     PRICEHIL 138 KV    DIS            .000         .000      P
          PRICEHIL     L      MAR-PRI  138 KV                   .000         .000      P
15870    500/138.MeadowBrook.T2&T4 (Sctnlz F)              Y Y Y S Y Y N N     NNNNNNNNNNYNNNNNNNNNYYNNN NNNNNNNNNNYNNNNNNNNNYYNNN
          MEADOWBR     OP     MD13     138 KV    CB             .000         .000      P
          MEADOWBR     OP     MDL10    500 KV    CB             .000         .000      P
          MEADOWBR     OP     B18      500 KV    CB             .000         .000      P
          MEADOWBR     X      TRAN  2  500 KV                   .000         .000      P
          MEADOWBR     OP     MDL08    500 KV    CB             .000         .000      P
          MEADOWBR     OP     MD14     138 KV    CB             .000         .000      P
          MEADOWBR     OP     MDL3 CB  500 KV    CB             .000         .000      P
          MEADOWBR     OP     MDL6 CB  500 KV    CB             .000         .000      P
          MEADOWBR     OP     MD17     138 KV    CB             .000         .000      P
          MEADOWBR     OP     MD16     138 KV    CB             .000         .000      P
          MEADOWBR     X      TRAN  4  500 KV                   .000         .000      P
15880    500/138.MeadowBrook.T1 (Sctnlz)                   Y Y Y S Y Y N N     YNNNNNNNNNYNNNNNNNNNNNNYN YNNNNNNNNNYNNNNNNNNNNNNYN
          MEADOWBR     OP     MD8      138 KV    CB             .000         .000      P
          MEADOWBR     OP     MD7      138 KV    CB             .000         .000      P
          MEADOWBR     X      TRAN  1  500 KV                   .000         .000      P
          MEADOWBR     OP     1XFMR HS 500 KV    DIS            .000         .000      P
15890    500/138.MeadowBrook.T2 (Sctnlz)                   Y Y Y S Y Y N N     YNNNNNNNNNYNNNNNNNNNNNNYN YNNNNNNNNNYNNNNNNNNNNNNYN
          MEADOWBR     OP     2XFMR HS 500 KV    DIS            .000         .000      P
          MEADOWBR     X      TRAN  2  500 KV                   .000         .000      P
          MEADOWBR     OP     MD14     138 KV    CB             .000         .000      P
          MEADOWBR     OP     MD13     138 KV    CB             .000         .000      P
15900    500/138.MeadowBrook.T4 (Sctnlz)                   Y Y Y S Y Y N N     YNNNNNNNNNYNNNNNNNNNNNNYN YNNNNNNNNNYNNNNNNNNNNNNYN
          MEADOWBR     OP     MD16     138 KV    CB             .000         .000      P
          MEADOWBR     OP     MD17     138 KV    CB             .000         .000      P
          MEADOWBR     OP     4XFMR HS 500 KV    DIS            .000         .000      P
          MEADOWBR     X      TRAN  4  500 KV                   .000         .000      P
15910    500/138.MeadowBrook.T3 (Sctnlz)                   Y Y Y S Y Y N N     YNNNNNNNNNYNNNNNNNNNNNNYN YNNNNNNNNNYNNNNNNNNNNNNYN
          MEADOWBR     X      TRAN  3  500 KV                   .000         .000      P
          MEADOWBR     OP     MD10     138 KV    CB             .000         .000      P
          MEADOWBR     OP     MD11     138 KV    CB             .000         .000      P
          MEADOWBR     OP     3XFMR HS 500 KV    DIS            .000         .000      P
15920    500/138.MeadowBrook.T1&T3 (Sctnlz F)              Y Y Y S Y Y N N     NNNNNNNNNNYNNNNNNNNNYYNNN NNNNNNNNNNYNNNNNNNNNYYNNN
          MEADOWBR     OP     MDL09    500 KV    CB             .000         .000      P
          MEADOWBR     OP     MDL2 CB  500 KV    CB             .000         .000      P
          MEADOWBR     X      TRAN  3  500 KV                   .000         .000      P
          MEADOWBR     OP     MD8      138 KV    CB             .000         .000      P
          MEADOWBR     OP     MD11     138 KV    CB             .000         .000      P
          MEADOWBR     OP     1XFMR HS 500 KV    DIS            .000         .000      P
          MEADOWBR     OP     MD7      138 KV    CB             .000         .000      P
          MEADOWBR     OP     3XFMR HS 500 KV    DIS            .000         .000      P
          MEADOWBR     OP     MD10     138 KV    CB             .000         .000      P
          MEADOWBR     OP     MDL07    500 KV    CB             .000         .000      P
          MEADOWBR     OP     B15      500 KV    CB             .000         .000      P
          MEADOWBR     X      TRAN  1  500 KV                   .000         .000      P
          MEADOWBR     OP     MDL5 CB  500 KV    CB             .000         .000      P
15930    L138.Meadowbrook-Strasburg + Strasburg.Cap        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MEADOWBR     OP     MD5      138 KV    CB             .000         .000      P
          STRASBUR     LD     T1_AP    138 KV                   .000         .000      P
          STRASBUR     OP     T1 DIS   138 KV    DIS            .000         .000      P
          MEADOWBR     OP     STRASBUR 138 KV    DIS            .000         .000      P
          MEADOWBR     OP     MD4      138 KV    CB             .000         .000      P
          STRASBUR     OP     T3 DIS   138 KV    DIS            .000         .000      P
          STRASBUR     CP     CAP2     138 KV                   .000         .000      P
          STRASBUR     OP     CAP2 CB  138 KV    CB             .000         .000      P
          STRASBUR     L      MEA-STR  138 KV                   .000         .000      P
          STRASBUR     OP     MEADOWBR 138 KV    DIS            .000         .000      P
          STRASBUR     OP     BUSTIE   138 KV    CB             .000         .000      P
          STRASBUR     LD     T3       138 KV                   .000         .000      P
15940    L138.Edinburg-Strasburg+230/115.Edinburg.TX3&4    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STRASBUR     L      EDI-STR  138 KV                   .000         .000      P
          EDINBUR4     X      TX4      138 KV                   .000         .000      P
          EDINBUR4     OP     L312     115 KV    CB             .000         .000      P
          EDINBUR4     X      TX3      138 KV                   .000         .000      P
          STRASBUR     OP     T1 DIS   138 KV    DIS            .000         .000      P
          STRASBUR     OP     BUSTIE   138 KV    CB             .000         .000      P
          STRASBUR     OP     EDINBURG 138 KV    DIS            .000         .000      P
          EDINBUR4     OP     L412     115 KV    CB             .000         .000      P
15950    MEADOWBR-WWINCHES-REDBUD (APS)                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          REDBUD       OP     WWINCHES 138 KV    CB             .000         .000      P
          WWINCHES     LD     T2       138 KV                   .000         .000      P
          WWINCHES     OP     BUS TIE  138 KV    DIS            .000         .000      P
          WWINCHES     OP     T2 DIS   138 KV    DIS            .000         .000      P
          MEADOWBR     OP     MD8      138 KV    CB             .000         .000      P
          MEADOWBR     OP     MD9      138 KV    CB             .000         .000      P
          MEADOWBR     L      MEA-WWI  138 KV                   .000         .000      P
          WWINCHES     OP     REDBUD   138 KV    DIS            .000         .000      P
          WWINCHES     LD     T1       138 KV                   .000         .000      P
          REDBUD       L      RED-WWI  138 KV                   .000         .000      P
          WWINCHES     OP     MEADOWBR 138 KV    DIS            .000         .000      P
          WWINCHES     OP     T1 DIS   138 KV    DIS            .000         .000      P
15960    MESSICRD-MORGAN (APS)                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MESSICRD     OP     MORGAN   138 KV    DIS            .000         .000      P
          MORGAN       OP     MESSICRD 138 KV    DIS            .000         .000      P
          MESSICRD     L      MES-MOR  138 KV                   .000         .000      P
15970    MESSICRD-RIDGELEY (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RIDGELEY     OP     MESSICRD 138 KV    CB             .000         .000      P
          MESSICRD     OP     RIDGELEY 138 KV    DIS            .000         .000      P
          MESSICRD     L      MES-RID  138 KV                   .000         .000      P
15990    L230.Milesburg-DalesSummit-Shingletown            Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SHINGLET     OP     DALESUMM 230 KV    CB             .000         .000      P
          DALESUMM     L      DAL-SHI  230 KV                   .000         .000      P
          DALESUMM     L      DAL-MIL  230 KV                   .000         .000      P
          MILESBUR     OP     DALESUMM 230 KV    CB             .000         .000      P
16000    L138.Millville-SleepyHollow                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SLEEPYHO     LD     T2       138 KV                   .000         .000      P
          SLEEPYHO     OP     BUSTIE   138 KV    CB             .000         .000      P
          SLEEPYHO     L      MIL-SLE  138 KV                   .000         .000      P
          MILLVILL     OP     SLEEPYHO 138 KV    CB             .000         .000      P
          SLEEPYHO     OP     MILLVILL 138 KV    DIS            .000         .000      P
          SLEEPYHO     LD     T1       138 KV                   .000         .000      P
16040    MONOCACY-OLDFARM-RINGOLD (APS)                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OLDFARM      L      OLD-RIN  230 KV                   .000         .000      P
          MONOCACY     OP     OLDFARM  230 KV    CB             .000         .000      P
          OLDFARM      OP     SW-T1    230 KV    DIS            .000         .000      P
          MONOCACY     L      MON-OLD  230 KV                   .000         .000      P
          RINGGOLD     OP     MONOCACY 230 KV    CB             .000         .000      P
16050    PICKENS-MONTERVILLE-LINWOOD (APS)                 Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MONTERVI     OP     T1 DIS   138 KV    DIS            .000         .000      P
          LINWOOD      LD     T2       138 KV                   .000         .000      P
          MONTERVI     OP     1045     138 KV    DIS            .000         .000      P
          LINWOOD      L      LIN-MON  138 KV                   .000         .000      P
          LINWOOD      OP     T2 DIS   138 KV    DIS            .000         .000      P
          LINWOOD      OP     MONTERVI 138 KV    DIS            .000         .000      P
          PICKENS      OP     MONTERVI 138 KV    CB             .000         .000      P
          PICKENS      L      MON-PIC  138 KV                   .000         .000      P
          LINWOOD      LD     T1       138 KV                   .000         .000      P
          MONTERVI     LD     T1       138 KV                   .000         .000      P
          LINWOOD      OP     T1 DIS   138 KV    DIS            .000         .000      P
          MONTERVI     OP     DUMPIC   138 KV    DIS            .000         .000      P
          LINWOOD      OP     BUS TIE  138 KV    DIS            .000         .000      P
16060    MTAIRY-NEWMARKE (APS)                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NEWMARKE     OP     MTAIRY   230 KV    DIS            .000         .000      P
          NEWMARKE     L      MTA-NEW  230 KV                   .000         .000      P
          MTAIRY       OP     NEWMARKE 230 KV    CB             .000         .000      P
16070    SPRINGDA-MURRYCRE-SUNDELMT-WHITEVAL (APS)         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SUNDELMT     OP     MURRY    138 KV    DIS            .000         .000      P
          MURRYCRE     OP     T61 DIS  138 KV    DIS            .000         .000      P
          MURRYCRE     LD     T62      138 KV                   .000         .000      P
          MURRYCRE     OP     SUNOCO   138 KV    DIS            .000         .000      P
          SUNDELMT     OP     SUN      138 KV    DIS            .000         .000      P
          SUNDELMT     OP     WHITE    138 KV    DIS            .000         .000      P
          MURRYCRE     L      MUR-SUN  138 KV                   .000         .000      P
          MURRYCRE     OP     BUS TIE  138 KV    DIS            .000         .000      P
          SPRINGDA     OP     MURRYCRE 138 KV    CB             .000         .000      P
          SUNDELMT     LD     SUNOCO   138 KV                   .000         .000      P
          WHITEVAL     OP     SPRING   138 KV    CB             .000         .000      P
          MURRYCRE     OP     SPRINGDA 138 KV    DIS            .000         .000      P
          SPRINGDA     L      MUR-SPR  138 KV                   .000         .000      P
          WHITEVAL     L      SUN-WHI  138 KV                   .000         .000      P
          MURRYCRE     LD     T61      138 KV                   .000         .000      P
          MURRYCRE     OP     T62 DIS  138 KV    DIS            .000         .000      P
16080    L138.PadenCity-NewMartinsville-Natrium.68         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NEWMARTI     OP     T1 DIS   138 KV    DIS            .000         .000      P
          NEWMARTI     OP     HANN CB  138 KV    CB             .000         .000      P
          PADENCIT     OP     NEWMARTI 138 KV    CB             .000         .000      P
          NEWMARTI     OP     BUS TIE  138 KV    DIS            .000         .000      P
          NATRIUM2     OP     M3       138 KV    CB             .000         .000      P
          NEWMARTI     U      HANN NUG 138 KV                   .000         .000      P
          NEWMARTI     OP     PADENCIT 138 KV    DIS            .000         .000      P
          NATRIUM2     OP     M        138 KV    CB             .000         .000      P
          NEWMARTI     LD     T2       138 KV                   .000         .000      P
          NEWMARTI     L      NAT-NEW  138 KV                   .000         .000      P
          NEWMARTI     OP     T2 DIS   138 KV    DIS            .000         .000      P
          NEWMARTI     OP     NATRIUM  138 KV    DIS            .000         .000      P
          NEWMARTI     L      NEW-PAD  138 KV                   .000         .000      P
          NEWMARTI     LD     T1       138 KV                   .000         .000      P
16090    NPETERSB-NFRANKLI-SENECACA (APS)                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NFRANKLI     OP     N PETERS 138 KV    DIS            .000         .000      P
          NPETERSB     OP     NFRANKLI 138 KV    CB             .000         .000      P
          SENECACA     L      NFR-SEN  138 KV                   .000         .000      P
          NPETERSB     L      NFR-NPE  138 KV                   .000         .000      P
          NFRANKLI     LD     T2       138 KV                   .000         .000      P
          NFRANKLI     OP     T2 DIS   138 KV    DIS            .000         .000      P
          SENECACA     OP     NORTHFRA 138 KV    DIS            .000         .000      P
          NFRANKLI     OP     SENECACA 138 KV    DIS            .000         .000      P
16100    L138.Page-North Shenandoah                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NSHE APS     OP     PAGE     138 KV    CB             .000         .000      P
          PAGE         OP     NORTHSHE 138 KV    DIS            .000         .000      P
          PAGE         L      NSH-PAG  138 KV                   .000         .000      P
16110    L115.EndlessCaverns-Merck5-NorthShenandoah.118    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          NSHENVPC     L      118B     115 KV                   .000         .000      P
          MERCK5       LD     TX2      35 KV                    .000         .000      P
          MERCK5       X      TX2      115 KV                   .000         .000      P
          MERCK5       X      TX4      115 KV                   .000         .000      P
          NSHENVPC     L      118A     115 KV                   .000         .000      P
          ENDCAVRN     OP     L5118    115 KV    CB             .000         .000      P
          NSHE APS     L      END-NSH  115 KV                   .000         .000      P
          NSHE APS     X      T3 XF    138 KV                   .000         .000      P
          MERCK5       CP     SC1      115 KV                   .000         .000      P
          MERCK5       OP     H202     115 KV    CB             .000         .000      P
          MERCK5       LD     TX4      35 KV                    .000         .000      P
          NSHE APS     OP     T3 HSCB  138 KV    CB             .000         .000      P
          MERCK5       OP     11802    115 KV    CB             .000         .000      P
16120    L138.Riverview-NVienna-WilliamsCrk (APS)          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WILLMCRK     OP     BUS TIE  138 KV    CB             .000         .000       
          RIVERVIE     OP     636      138 KV    CB             .000         .000       
          WILLMCRK     LD     T1       138 KV                   .000         .000       
          NVIENNA      LD     T1       138 KV                   .000         .000       
          WILLMCRK     OP     T1 DIS   138 KV    DIS            .000         .000       
          NVIENNA      OP     T1 DIS   138 KV    DIS            .000         .000       
          RIVERVIE     L      NVI-RIV  138 KV                   .000         .000       
          NVIENNA      L      NVI-WIL  138 KV                   .000         .000       
16130    OAKG APS GEN  1   (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OAKG APS     OP     SS1 DIS  138 KV    DIS            .000         .000      P
          OAKG APS     OP     4        138 KV    CB             .000         .000      P
          OAKG APS     U      GEN 1    18 KV                    .000         .000      P
          OAKG APS     OP     1        138 KV    CB             .000         .000      P
          OAKG APS     LD     SS1 LOAD 138 KV                   .000         .000      P
16140    OAKG APS GEN  2   (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OAKG APS     LD     SS2 LOAD 138 KV                   .000         .000      P
          OAKG APS     OP     6        138 KV    CB             .000         .000      P
          OAKG APS     OP     3        138 KV    CB             .000         .000      P
          OAKG APS     OP     SS2 DIS  138 KV    DIS            .000         .000      P
          OAKG APS     U      GEN 2    18 KV                    .000         .000      P
16150    OAKMOUND-QUIETDEL (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          QUIETDEL     OP     OAKMOUND 138 KV    DIS            .000         .000      P
          OAKMOUND     OP     QUIETDEL 138 KV    CB             .000         .000      P
          QUIETDEL     L      OAK-QUI  138 KV                   .000         .000      P
16160    OSAGE    MEA NUG  (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          OSAGE        OP     MEA CB   138 KV    CB             .000         .000      P
16170    OSAGE-WESTOVER-RIVESVIL (APS)                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WOVE APS     OP     BUS TIE  138 KV    DIS            .000         .000      P
          RIVESVIL     L      RIV-WOV  138 KV                   .000         .000      P
          WOVE APS     OP     OSAGE    138 KV    DIS            .000         .000      P
          RIVESVIL     OP     WESTOVER 138 KV    CB             .000         .000      P
          WOVE APS     OP     T1 DIS   138 KV    DIS            .000         .000      P
          OSAGE        OP     WESTOVER 138 KV    CB             .000         .000      P
          WOVE APS     LD     T1       138 KV                   .000         .000      P
          OSAGE        L      OSA-WOV  138 KV                   .000         .000      P
          WOVE APS     OP     RIVESVIL 138 KV    DIS            .000         .000      P
16180    L138.Page-SPerryville                             Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SPERRYVI     LD     T2       138 KV                   .000         .000      P
          PAGE         OP     SPERRYVI 138 KV    CB             .000         .000      P
          SPERRYVI     L      PAG-SPE  138 KV                   .000         .000      P
          SPERRYVI     OP     T2 DIS   138 KV    DIS            .000         .000      P
          SPERRYVI     OP     DUMPAG   138 KV    DIS            .000         .000      P
16190    PAPERCIT-RIDG APS (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RIDG APS     OP     PAPERCIT 138 KV    CB             .000         .000      P
          PAPERCIT     L      PAP-RID  138 KV                   .000         .000      P
          PAPERCIT     OP     RIDGWAY  138 KV    DIS            .000         .000      P
16200    WILLIAM-PARSONS-LOUGHSLA (APS)                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          LOUGHSLA     OP     PARSONS  138 KV    CB             .000         .000      P
          WILLIAM      OP     PARSONS  138 KV    CB             .000         .000      P
          PARSONS      OP     WILLIAM  138 KV    DIS            .000         .000      P
          PARSONS      OP     LOUGHSLA 138 KV    DIS            .000         .000      P
          LOUGHSLA     L      LOU-PAR  138 KV                   .000         .000      P
          WILLIAM      L      PAR-WIL  138 KV                   .000         .000      P
          PARSONS      OP     T1 DIS   138 KV    DIS            .000         .000      P
          PARSONS      LD     T1       138 KV                   .000         .000      P
16210    L138.PineyFork-USS Clairton.Z-16                  Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          USSCLAIR     OP     Z-16CB   138 KV    CB             .000         .000      P
          PINEY FK     L      PIN-USS  138 KV                   .000         .000      P
          PINEY FK     OP     USSCLR   138 KV    DIS            .000         .000      P
16220    PINEY FK-WOODVILL 138 KV (APS)                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PINEY FK     OP     WOODVILL 138 KV    DIS            .000         .000      P
          WOODVILL     OP     PINEYFOR 138 KV    CB             .000         .000      P
          PINEY FK     L      PIN-WOO  138 KV                   .000         .000      P
16230    L500.Belmont-Pleasants.L1 + Pleasants.U1          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BELMONT      L      BEL-PLE1 500 KV                   .000         .000      P
          PLEA APS     X      TX1      500 KV                   .000         .000      P
          PLEA APS     U      GEN  1   26 KV                    .000         .000      P
          PLEA APS     LD     SS LOAD1 26 KV                    .000         .000      P
          BELMONT      OP     BL6      500 KV    CB             .000         .000      P
          BELMONT      OP     BL5      500 KV    CB             .000         .000      P
16240    L500.Belmont-Pleasants.L2 & Pleasants.U2          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BELMONT      OP     BL2      500 KV    CB             .000         .000      P
          BELMONT      L      BEL-PLE2 500 KV                   .000         .000      P
          BELMONT      OP     BL3      500 KV    CB             .000         .000      P
          PLEA APS     X      TX2      500 KV                   .000         .000      P
          PLEA APS     U      GEN  2   26 KV                    .000         .000      P
16250    500/138.Pruntytown.T1 & T2 (Sctnlz F)             Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNYYNNN NNNNNNNNNNNNNNNNNNNNYYNNN
          PRUNTYTO     OP     PL1 CB   500 KV    CB             .000         .000      P
          PRUNTYTO     X      TRAN  1  500 KV                   .000         .000      P
          PRUNTYTO     OP     P11      138 KV    CB             .000         .000      P
          PRUNTYTO     X      TRAN  2  500 KV                   .000         .000      P
          PRUNTYTO     OP     P12      138 KV    CB             .000         .000      P
          PRUNTYTO     OP     P9       138 KV    CB             .000         .000      P
          PRUNTYTO     OP     PL4 CB   500 KV    CB             .000         .000      P
          PRUNTYTO     OP     P8       138 KV    CB             .000         .000      P
16260    500/138.Pruntytown.Tran1 (Sctnlz)                 Y Y Y S Y Y N N     YNNNNNNNNNYNNNNNNNNNNNNYN YNNNNNNNNNYNNNNNNNNNNNNYN
          PRUNTYTO     OP     1XFMR HS 500 KV    CB             .000         .000      P
          PRUNTYTO     OP     P8       138 KV    CB             .000         .000      P
          PRUNTYTO     X      TRAN  1  500 KV                   .000         .000      P
          PRUNTYTO     OP     P9       138 KV    CB             .000         .000      P
16270    500/138.Pruntytown.Tran2 (Sctnlz)                 Y Y Y S Y Y N N     YNNNNNNNNNYNNNNNNNNNNNNYN YNNNNNNNNNYNNNNNNNNNNNNYN
          PRUNTYTO     OP     2XFMR HS 500 KV    CB             .000         .000      P
          PRUNTYTO     OP     P12      138 KV    CB             .000         .000      P
          PRUNTYTO     OP     P11      138 KV    CB             .000         .000      P
          PRUNTYTO     X      TRAN  2  500 KV                   .000         .000      P
16280    500/138.Pruntytown.T3 & T4 (Sctnlz F)             Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNYYNNN NNNNNNNNNNNNNNNNNNNNYYNNN
          PRUNTYTO     OP     P14      138 KV    CB             .000         .000      P
          PRUNTYTO     OP     P17      138 KV    CB             .000         .000      P
          PRUNTYTO     OP     P18      138 KV    CB             .000         .000      P
          PRUNTYTO     OP     P15      138 KV    CB             .000         .000      P
          PRUNTYTO     X      TRAN  4  500 KV                   .000         .000      P
          PRUNTYTO     OP     PL6 CB   500 KV    CB             .000         .000      P
          PRUNTYTO     X      TRAN  3  500 KV                   .000         .000      P
          PRUNTYTO     OP     PL2 CB   500 KV    CB             .000         .000      P
16290    500/138.Pruntytown.Tran3 (Sctnlz)                 Y Y Y S Y Y N N     YNNNNNNNNNYNNNNNNNNNNNNYN YNNNNNNNNNYNNNNNNNNNNNNYN
          PRUNTYTO     OP     3XFMR HS 500 KV    CB             .000         .000      P
          PRUNTYTO     OP     P15      138 KV    CB             .000         .000      P
          PRUNTYTO     X      TRAN  3  500 KV                   .000         .000      P
          PRUNTYTO     OP     P14      138 KV    CB             .000         .000      P
16300    500/138.Pruntytown.Tran4 (Sctnlz)                 Y Y Y S Y Y N N     YNNNNNNNNNYNNNNNNNNNNNNYN YNNNNNNNNNYNNNNNNNNNNNNYN
          PRUNTYTO     OP     P17      138 KV    CB             .000         .000      P
          PRUNTYTO     OP     P18      138 KV    CB             .000         .000      P
          PRUNTYTO     X      TRAN  4  500 KV                   .000         .000      P
          PRUNTYTO     OP     4XFMR HS 500 KV    CB             .000         .000      P
16310    PRUNTYTO-SHINNSRN (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PRUNTYTO     L      PRU-SHI  138 KV                   .000         .000      P
          PRUNTYTO     OP     P1       138 KV    CB             .000         .000      P
          PRUNTYTO     OP     P2       138 KV    CB             .000         .000      P
          SHINNSRN     OP     PRUNTYTO 138 KV    DIS            .000         .000      P
16320    REID-RINGGOLD (APS)                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          REID         OP     RINGGOLD 138 KV    CB             .000         .000      P
          RINGGOLD     L      REI-RIN  138 KV                   .000         .000      P
          RINGGOLD     OP     REID     138 KV    CB             .000         .000      P
16330    RINGGOLD T3       (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RINGGOLD     X      T3       230 KV                   .000         .000      P
          RINGGOLD     OP     MONOCACY 230 KV    CB             .000         .000      P
          RINGGOLD     OP     T3 CB    138 KV    CB             .000         .000      P
          RINGGOLD     OP     BUSTIE   230 KV    CB             .000         .000      P
16340    RINGGOLD T4       (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          RINGGOLD     X      T4       230 KV                   .000         .000      P
          RINGGOLD     OP     T4 CB    138 KV    CB             .000         .000      P
          RINGGOLD     OP     BUSTIE   230 KV    CB             .000         .000      P
          RINGGOLD     OP     FROSTOWN 230 KV    CB             .000         .000      P
16370    SALTSBUR-SOCIALHA (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SOCIALHA     L      SAL-SOC  138 KV                   .000         .000      P
          SOCIALHA     OP     SALTSBUR 138 KV    CB             .000         .000      P
          SALTSBUR     OP     SOCIALHA 138 KV    DIS            .000         .000      P
16380    SALTSBUR-VANDERGR (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SALTSBUR     OP     VANDERGR 138 KV    DIS            .000         .000      P
          VANDERGR     OP     SALTSBUR 138 KV    DIS            .000         .000      P
          SALTSBUR     L      SAL-VAN  138 KV                   .000         .000      P
16390    SMIT APS-WYLIERID (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WYLIERID     OP     W8       138 KV    CB             .000         .000      P
          WYLIERID     OP     W7       138 KV    CB             .000         .000      P
          WYLIERID     L      SMI-WYL  138 KV                   .000         .000      P
          SMIT APS     OP     WYLIERID 138 KV    DIS            .000         .000      P
16400    SPRINGDA ST5 (APS)                                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SPRINGDA     OP     ST5      138 KV    CB             .000         .000      P
          SPRINGDA     X      ST-5     138 KV                   .000         .000      P
          SPRINGDA     U      ST5      18 KV                    .000         .000      P
16410    SPRINGDA CT4 (APS)                                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SPRINGDA     U      CT4      18 KV                    .000         .000       
          SPRINGDA     X      CT-4     138 KV                   .000         .000       
          SPRINGDA     OP     CT4      138 KV    CB             .000         .000       
16420    SPRINGDA CT3 (APS)                                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SPRINGDA     OP     CT3      138 KV    CB             .000         .000      P
          SPRINGDA     U      CT3      18 KV                    .000         .000      P
          SPRINGDA     X      CT-3     138 KV                   .000         .000      P
16430    SPRINGDA AE 1-2 & AE (APS)                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SPRINGDA     X      AE       138 KV                   .000         .000      P
          SPRINGDA     U      AES 1    13 KV                    .000         .000      P
          SPRINGDA     U      AES 2    13 KV                    .000         .000      P
          SPRINGDA     OP     AE1_2 CB 138 KV    CB             .000         .000      P
16440    L138.Cheswick-Springdale.Z-58                     Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SPRINGDA     L      CHE-SPR  138 KV                   .000         .000      P
          SPRINGDA     OP     CHESWICK 138 KV    CB             .000         .000      P
          CHESWICK     OP     SPRING58 138 KV    CB             .000         .000      P
16450    WARRIORN GEN1 & G1 TX (APS)                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WARRIORN     X      G1 TX    138 KV                   .000         .000      P
          WARRIORN     OP     52L      138 KV    CB             .000         .000      P
          WARRIORN     U      GEN1     13 KV                    .000         .000      P
16460    WEIRTON-WYLIERID2 (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WEIRTON      OP     WYLIE2   138 KV    CB             .000         .000      P
          WYLIERID     L      WEI-WYL2 138 KV                   .000         .000      P
          WYLIERID     OP     W4       138 KV    CB             .000         .000      P
          WYLIERID     OP     W5       138 KV    CB             .000         .000      P
16470    WEIRTON-WYLIERID  (APS)                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WEIRTON      OP     WYLIE1   138 KV    CB             .000         .000      P
          WYLIERID     OP     W12      138 KV    CB             .000         .000      P
          WYLIERID     L      WEI-WYL  138 KV                   .000         .000      P
16480    L138.Windsor-Tiltonsville-WestBellaire            Y Y Y 1 Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WBELLAI2     OP     E        138 KV    CB             .000         .000      P
          WIND APS     L      TIL-WIN  138 KV                   .000         .000      P
          TILTONS2     OP     G DIS    69 KV     DIS            .000         .000      P
          WBELLAI2     OP     E2       138 KV    CB             .000         .000      P
          TILTONS2     L      TIL-WBE1 138 KV                   .000         .000      P
          TILTONS2     X      XFMR     138 KV                   .000         .000      P
          WIND APS     OP     TILTONSV 138 KV    CB             .000         .000      P
16500    L345.Sammis-WylieRidge.240 + Seneca.1.Pump        Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SAMMISFE     OP     295      345 KV    CB             .000         .000      P
          WYLIERID     OP     WK3 CB   345 KV    CB             .000         .000      P
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          WYLIERID     OP     WK2 CB   345 KV    CB             .000         .000      P
          SENECA       U      1GEN     13 KV                    .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
          SAMMISFE     OP     298      345 KV    CB             .000         .000      P
16510    L345.Sammis-WylieRidge.240 + Seneca.2.Pump        Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SAMMISFE     OP     295      345 KV    CB             .000         .000      P
          WYLIERID     OP     WK3 CB   345 KV    CB             .000         .000      P
          WYLIERID     OP     WK2 CB   345 KV    CB             .000         .000      P
          SAMMISFE     OP     298      345 KV    CB             .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
          SENECA       X      NO2 230  230 KV                   .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
16520    L345.Sammis-WylieRidge.240 + Seneca.1&2.Pump      Y Y Y S Y Y N N     NNNYNNNNNNNNNNNNNNNNNNNNN NNNYNNNNNNNNNNNNNNNNNNNNN
          SAMMISFE     OP     298      345 KV    CB             .000         .000      P
          SAMMISFE     OP     295      345 KV    CB             .000         .000      P
          WYLIERID     OP     WK3 CB   345 KV    CB             .000         .000      P
          SENECA       X      NO1 230  230 KV                   .000         .000      P
          SENECA       U      1GEN     13 KV                    .000         .000      P
          SENECA       OP     NO1 GEN  230 KV    CB             .000         .000      P
          WYLIERID     OP     WK2 CB   345 KV    CB             .000         .000      P
          SENECA       U      2GEN     13 KV                    .000         .000      P
          SENECA       X      NO2 230  230 KV                   .000         .000      P
          SENECA       OP     NO2 GEN  230 KV    CB             .000         .000      P
16530    L345.Tidd-WylieRidge                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          WYLIERID     L      TID-WYL1 345 KV                   .000         .000      P
          TIDD_AEP     OP     CC       345 KV    CB             .000         .000      P
          WYLIERID     OP     WK5 CB   345 KV    CB             .000         .000      P
          WYLIERID     OP     WK4 CB   345 KV    CB             .000         .000      P
          TIDD_AEP     OP     CC2      345 KV    CB             .000         .000      P
          WYLIERID     OP     TIDD     345 KV    DIS            .000         .000      P
16560    SPRINGDA-WYCOFF-YUKON (APS)                       Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          YUKON        L      WYC-YUK  138 KV                   .000         .000      P
          SPRINGDA     OP     WYCOFF   138 KV    CB             .000         .000      P
          WYCOFF       LD     T1       138 KV                   .000         .000      P
          WYCOFF       OP     T1 DIS   138 KV    DIS            .000         .000      P
          SPRINGDA     L      SPR-WYC  138 KV                   .000         .000      P
          WYCOFF       OP     DUMSPR   138 KV    DIS            .000         .000      P
          YUKON        OP     Y10      138 KV    CB             .000         .000      P
          WYCOFF       OP     DUMYUK   138 KV    DIS            .000         .000      P
          YUKON        OP     Y9       138 KV    CB             .000         .000      P
16570    Wylie Ridge #5 & #6 500/345 kV trans              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WYLIERID     X      TRAN  5  500 KV                   .000         .000      P
          WYLIERID     OP     WK1 CB   345 KV    CB             .000         .000      P
          WYLIERID     OP     WL1 CB   500 KV    CB             .000         .000      P
          WYLIERID     OP     6XFMR HS 500 KV    DIS            .000         .000      P
          WYLIERID     OP     WK4 CB   345 KV    CB             .000         .000      P
          WYLIERID     OP     6XFMR LS 345 KV    DIS            .000         .000      P
          WYLIERID     X      TRAN  6  500 KV                   .000         .000      P
          WYLIERID     OP     WL4 CB   500 KV    CB             .000         .000      P
16580    Wylie Ridge #7 & #8 500/345 kV trans              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WYLIERID     X      TRAN  7  500 KV                   .000         .000      P
          WYLIERID     OP     WL2 CB   500 KV    CB             .000         .000      P
          WYLIERID     X      TRAN  8  500 KV                   .000         .000      P
          WYLIERID     OP     WK5 CB   345 KV    CB             .000         .000      P
          WYLIERID     OP     WL5 CB   500 KV    CB             .000         .000      P
          WYLIERID     OP     WK6 CB   345 KV    CB             .000         .000      P
16590    345/138.Wylie Ridge.1TX & 2TX (Sctnlz F)          Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNYYNNN NNNNNNNNNNNNNNNNNNNNYYNNN
          WYLIERID     OP     WK1 CB   345 KV    CB             .000         .000      P
          WYLIERID     X      1TX      345 KV                   .000         .000      P
          WYLIERID     OP     W2       138 KV    CB             .000         .000      P
          WYLIERID     X      2TX      345 KV                   .000         .000      P
          WYLIERID     OP     W1       138 KV    CB             .000         .000      P
          WYLIERID     OP     WK2 CB   345 KV    CB             .000         .000      P
16600    WYLIERID 1TX (APS)                                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WYLIERID     OP     1 XFMR   345 KV    DIS            .000         .000      P
          WYLIERID     X      1TX      345 KV                   .000         .000      P
          WYLIERID     OP     W1       138 KV    CB             .000         .000      P
          WYLIERID     OP     W2       138 KV    CB             .000         .000      P
16610    WYLIERID 2TX (APS)                                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WYLIERID     X      2TX      345 KV                   .000         .000      P
          WYLIERID     OP     2TX 138  138 KV    DIS            .000         .000      P
          WYLIERID     OP     2 XFMR   345 KV    DIS            .000         .000      P
16620    WYLIERID 3TX (APS)                                Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          WYLIERID     OP     W3       138 KV    CB             .000         .000      P
          WYLIERID     OP     W6       138 KV    CB             .000         .000      P
          WEIRTON      L      WEI-WYL  138 KV                   .000         .000      P
          WYLIERID     OP     W9       138 KV    CB             .000         .000      P
          WYLIERID     OP     WK6 CB   345 KV    CB             .000         .000      P
          WYLIERID     OP     WK3 CB   345 KV    CB             .000         .000      P
          WYLIERID     OP     W12      138 KV    CB             .000         .000      P
          WYLIERID     X      3TX      345 KV                   .000         .000      P
16630    L500.SouthBend-Yukon                              Y Y Y S Y Y N N     YNNNNYNYNNNNNNYNYNNNNNYYN YNNNNYNYNNNNNNYNYNNNNNYYN
          YUKON        OP     YL4 CB   500 KV    CB             .000         .000      P
          SBEND        OP     DUMYUKON 500 KV    DIS            .000         .000      P
          SBEND        OP     SBL1     500 KV    CB             .000         .000      P
          SBEND        L      SBE-YUK  500 KV                   .000         .000      P
          YUKON        OP     SBEND    500 KV    DIS            .000         .000      P
          SBEND        OP     SBL3     500 KV    CB             .000         .000      P
          YUKON        OP     YL6 CB   500 KV    CB             .000         .000      P
16640    SBEND UNIT C1 (APS)                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SBEND        U      CT1      18 KV                    .000         .000      P
16650    SBEND UNIT C2 (APS)                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SBEND        U      CT2      18 KV                    .000         .000      P
16660    SBEND UNIT C3 (APS)                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SBEND        U      CT3      18 KV                    .000         .000      P
16670    SBEND UNIT C4 (APS)                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SBEND        U      CT4      18 KV                    .000         .000      P
16680    YOUNGWOO-YUKON (APS)                              Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          YOUNGWOO     OP     YUKON    138 KV    CB             .000         .000      P
          YUKON        OP     Y3       138 KV    CB             .000         .000      P
          YUKON        OP     Y1       138 KV    CB             .000         .000      P
          YUKON        L      YOU-YUK  138 KV                   .000         .000      P
16690    500/138.Yukon.T1 & T3 (Failed Sect.)              Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNYYNNN NNNNNNNNNNNNNNNNNNNNYYNNN
          YUKON        OP     YL1 CB   500 KV    CB             .000         .000      P
          YUKON        OP     Y12      138 KV    CB             .000         .000      P
          YUKON        OP     Y2       138 KV    CB             .000         .000      P
          YUKON        OP     YL4 CB   500 KV    CB             .000         .000      P
          YUKON        OP     Y16      138 KV    CB             .000         .000      P
          YUKON        X      TRAN  3  500 KV                   .000         .000      P
          YUKON        X      TRAN  1  500 KV                   .000         .000      P
16700    500/138.Yukon.T1 (Sect.)                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          YUKON        OP     1XFMR HS 500 KV    DIS            .000         .000      P
          YUKON        OP     Y12      138 KV    CB             .000         .000      P
          YUKON        OP     Y2       138 KV    CB             .000         .000      P
          YUKON        X      TRAN  1  500 KV                   .000         .000      P
16710    500/138.Yukon.T3 (Sect.)                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          YUKON        X      TRAN  3  500 KV                   .000         .000      P
          YUKON        OP     3XFMR HS 500 KV    DIS            .000         .000      P
          YUKON        OP     Y16      138 KV    CB             .000         .000      P
16720    500/138.Yukon.T2 & T4 (Failed Sect.)              Y Y Y S Y Y N N     NNNNNNNNNNNNNNNNNNNNYYNNN NNNNNNNNNNNNNNNNNNNNYYNNN
          YUKON        OP     Y17      138 KV    CB             .000         .000      P
          YUKON        OP     Y14      138 KV    CB             .000         .000      P
          YUKON        OP     Y4       138 KV    CB             .000         .000      P
          YUKON        OP     YL3 CB   500 KV    CB             .000         .000      P
          YUKON        X      TRAN  4  500 KV                   .000         .000      P
          YUKON        X      TRAN  2  500 KV                   .000         .000      P
          YUKON        OP     YL6 CB   500 KV    CB             .000         .000      P
16730    500/138.Yukon.T2 (Sect.)                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          YUKON        OP     Y17      138 KV    CB             .000         .000       
          YUKON        OP     2XFMR HS 500 KV    DIS            .000         .000       
          YUKON        X      TRAN  2  500 KV                   .000         .000       
16740    500/138.Yukon.T4 (Sect.)                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          YUKON        OP     4XFMR HS 500 KV    DIS            .000         .000       
          YUKON        OP     Y4       138 KV    CB             .000         .000       
          YUKON        OP     Y14      138 KV    CB             .000         .000       
          YUKON        X      TRAN  4  500 KV                   .000         .000       
16750    HIGHLAND TRAN 1 345/138 KV (OE)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HIGHLAOE     OP     24       138 KV    CB             .000         .000      P
          HIGHLAOE     OP     95       345 KV    CB             .000         .000      P
          HIGHLAOE     OP     122      345 KV    CB             .000         .000      P
          HIGHLAOE     OP     172      345 KV    CB             .000         .000      P
          HIGHLAOE     OP     30       138 KV    CB             .000         .000      P
          HIGHLAOE     X      1        345 KV                   .000         .000      P
16760    HIGHLAND TRAN 2 345/138 KV (OE)                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          HIGHLAOE     OP     101      345 KV    CB             .000         .000      P
          HIGHLAOE     OP     175      345 KV    CB             .000         .000      P
          HIGHLAOE     OP     128      345 KV    CB             .000         .000      P
          HIGHLAOE     OP     46       138 KV    CB             .000         .000      P
          HIGHLAOE     X      2        345 KV                   .000         .000      P
          HIGHLAOE     OP     40       138 KV    CB             .000         .000      P
16790    L345.Chamberlin-Hanna(OE)                         Y Y Y S Y Y N N     YNNNNNNNYNNNNNNNNNNNNNNYN YNNNNNNNYNNNNNNNNNNNNNNYN
          HANNAOE      OP     DUMC     345 KV    DIS            .000         .000       
          HANNAOE      L      CHA-HAN  345 KV                   .000         .000       
          CHAMBROE     OP     DUMH     345 KV    DIS            .000         .000       
          CHAMBROE     OP     B89      345 KV    CB             .000         .000       
          HANNAOE      OP     106      345 KV    CB             .000         .000       
          HANNAOE      OP     105      345 KV    CB             .000         .000       
          CHAMBROE     OP     B88      345 KV    CB             .000         .000       
16800    L345.Hoytdale-Mansfield                           Y Y Y S Y Y N N     YNNNNNNNYNNNNNNNNNNNNNYYN YNNNNNNNYNNNNNNNNNNNNNYYN
          HOYTDAL2     L      MAN-HOY1 345 KV                   .000         .000       
          HOYTDAL2     OP     DUM18206 345 KV    DIS            .000         .000       
          HOYTDAL2     OP     106      345 KV    CB             .000         .000       
          MANSFIEL     OP     DUM18205 345 KV    DIS            .000         .000       
          MANSFIEL     OP     50       345 KV    CB             .000         .000       
          MANSFIEL     OP     46       345 KV    CB             .000         .000       
          HOYTDAL2     OP     102      345 KV    CB             .000         .000       
16810    L138.Hoytdale-Maple                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          MAPLEOE      OP     B6       138 KV    CB             .000         .000      P
          HOYTDAL2     OP     6        138 KV    CB             .000         .000      P
          HOYTDAL2     L      HOY-MAP1 138 KV                   .000         .000      P
          HOYTDAL2     OP     2        138 KV    CB             .000         .000      P
          MAPLEOE      OP     B22      138 KV    CB             .000         .000      P
16820    L345.BeaverValley-Mansfield.316                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          MANSFIEL     OP     50       345 KV    CB             .000         .000       
          MANSFIEL     L      BEA-MAN4 345 KV                   .000         .000       
          MANSFIEL     OP     54       345 KV    CB             .000         .000       
          BEAV DUQ     OP     316-1    345 KV    CB             .000         .000       
16830    L345.BeaverValley-Mansfield.310                   Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          MANSFIEL     OP     34       345 KV    CB             .000         .000      P
          BEAV DUQ     OP     310-2    345 KV    CB             .000         .000      P
          MANSFIEL     L      BEA-MAN5 345 KV                   .000         .000      P
          MANSFIEL     OP     38       345 KV    CB             .000         .000      P
16860    345/138.Star(FE).T1                               Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          STAR_FE      OP     232      345 KV    CB             .000         .000       
          STAR_FE      CP     CAP2     345 KV                   .000         .000       
          STAR_FE      X      1        345 KV                   .000         .000       
          STAR_FE      OP     2        138 KV    CB             .000         .000       
          STAR_FE      OP     B258     345 KV    CB             .000         .000       
          STAR_FE      OP     3        138 KV    CB             .000         .000       
          STAR_FE      OP     109      345 KV    CB             .000         .000       
          STAR_FE      OP     14       345 KV    CB             .000         .000       
16870    L345.Tidd-Collier                                 Y Y Y 1 Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          TIDD_AEP     L      COL-TID  345 KV                   .000         .000      P
          TIDD_AEP     OP     CC1      345 KV    CB             .000         .000      P
          TIDD_AEP     OP     CC       345 KV    CB             .000         .000      P
          COLLIER      OP     301-1    345 KV    CB             .000         .000      P
          COLLIER      OP     301-2    345 KV    CB             .000         .000      P
16880    345/138.BeaverValley.T1-3                         Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          BEAV DUQ     OP     1_3TIECB 345 KV    CB             .000         .000      P
          BEAV DUQ     X      1_3TIE   345 KV                   .000         .000      P
          BEAV DUQ     OP     1_3TIECB 138 KV    CB             .000         .000      P
16890    L345.BeaverValley-Crescent.318                    Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNYYN YNNNNNNNNNNNNNNNNNNNNNYYN
          BEAV DUQ     L      BEA-CRE  345 KV                   .000         .000       
          BEAV DUQ     OP     318-3    345 KV    CB             .000         .000       
          BEAV DUQ     OP     318-4    345 KV    CB             .000         .000       
          CRES DUQ     OP     BEAV1DUQ 345 KV    CB             .000         .000       
          CRES DUQ     OP     BEAV2DUQ 345 KV    CB             .000         .000       
16900    L500.BathCounty-Valley.548                        Y Y Y 4 Y Y N N     YYNNNYYNNNNNNNNNNNNYNNNYN YYNNNYYNNNNNNNNNNNNYNNNYN
          VALLEY4      OP     548T549  500 KV    CB             .000         .000      P
          VALLEY4      S      548CAPA  500 KV                   .000         .000      P
          VALLEY4      OP     H1T548   500 KV    CB             .000         .000      P
          BATHCO       L      548A     500 KV                   .000         .000      P
          BATHCO       OP     H2T548   500 KV    CB             .000         .000      P
          BATHCO       OP     H3T548   500 KV    CB             .000         .000      P
16910    L115.Eclipse-Piney.1038                           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          PINEY        OP     ECLIPSEA 115 KV    CB             .000         .000      P
          PINEY        OP     ECLIPSSF 115 KV    CB             .000         .000      P
          ECLIPSE      OP     PINEY115 115 KV    CB             .000         .000      P
          PINEY        L      ECL-PIN  115 KV                   .000         .000      P
16920    L115.Seward-Florence-BlairsvilleEast-Shelocta.1002Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          SEWARD       OP     FLORENSF 115 KV    CB             .000         .000       
          BLAIRSVE     OP     FLRNC115 115 KV    CB             .000         .000       
          BLAIRSVE     L      BLA-FLO  115 KV                   .000         .000       
          SHELOCTA     OP     BLRSVL   115 KV    CB             .000         .000       
          FLORENCE     LD     T2 LOAD  115 KV                   .000         .000       
          BLAIRSVE     L      BLA-SHE  115 KV                   .000         .000       
          SEWARD       L      FLO-SEW  115 KV                   .000         .000       
16930    L115.BonAir-Johnstown.1032                        Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          JOHNSTOW     OP     B49      115 KV    CB             .000         .000      P
          BONAIR       L      BON-JOH  115 KV                   .000         .000      P
          BONAIR       OP     BSSEC115 115 KV    CB             .000         .000      P
16940    L115.BonAir-Hilltop.1004                          Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          BONAIR       L      BON-HIL  115 KV                   .000         .000       
          HILLTOP      OP     B14      115 KV    CB             .000         .000       
          BONAIR       OP     BSSEC115 115 KV    CB             .000         .000       
16960    L115.Eclipse-ClarkSummit-Grandview.1009           Y Y Y S Y Y N N     YNNNNNNNNNNNNNNNNNNNNNNYN YNNNNNNNNNNNNNNNNNNNNNNYN
          CLARKSUM     LD     2 TX     115 KV                   .000         .000       
          CLARKSUM     L      CLA-GRA  115 KV                   .000         .000       
          ECLIPSE      OP     GRANDVW  115 KV    CB             .000         .000       
          CLARKSUM     L      CLA-ECL  115 KV                   .000         .000       
          CLARKSUM     LD     1 TX     115 KV                   .000         .000       
          GRANDVIE     OP     ECLIPSE  115 KV    CB             .000         .000       
16970    L115.Claysburg-Krayn                              Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNNYN YNNYNNNNNNNNNNNNNNNNNNNYN
          CLAYSBUR     OP     B44      115 KV    CB             .000         .000      P
          CLAYSBUR     OP     B45      115 KV    CB             .000         .000      P
          KRAYN        OP     1123CB3  115 KV    CB             .000         .000      P
          KRAYN        OP     1123CB1  115 KV    CB             .000         .000      P
          CLAYSBUR     L      CLA-KRA  115 KV                   .000         .000      P
16980    L115.Hilltop-Krayn-RachelHill (HillclayJct&Salix) Y Y Y S Y Y N N     YNNYNNNNNNNNNNNNNNNNNNNYN YNNYNNNNNNNNNNNNNN