Transmission Owner Guidelines

Transmission Owner Technical Guidelines & Recommendations below, formerly were referred to as the “PJM TSDS Technical Requirements”, as published by the PJM Transmission & Sustation Design Committee (TSDS).

The documents included here are still subject to PJM's review and may thus potentially change before being formally published pursuant to Section 1.2c of the PJM Open Access Transmission Tariff (PDF).

These documents were originally developed for PJM by TSDS member companies when PJM’s footprint matched the NERC MAAC Region (contributing companies included AE, BGC, DPL, JCPL, MetEd, PECO, PENELEC, PEPCO, PPL and PSEG.) Many of these companies often reference these documents for their Technical Requirements and Standards as defined in the PJM OATT. PJM now extends into multiple NERC regions. New members typically reference their own documents and therefore these documents no longer represent all of PJM. However, all PJM members are welcome to reference these documents.

Date
I. Introduction - Technical Requirements and Design Philosophy (PDF) 06.2002
II. Transmission System Design Criteria (PDF) 11.2001
III. Substation Bus Configuration and Substation Design Requirements (PDF) 06.2002
IV. Spare Equipment Philosophy (PDF) 02.1999
V. Design, Application, Maintenance and Operation Technical Requirements
a. Overhead Transmission Lines (PDF) 01.2002
b. Power Cables  (PDF) 03.2002
c. Large Power Transformers  (PDF) 06.2002
d. Circuit Breakers (PDF) 06.2002
e. Load Interrupting Switches (Circuit Switches) (PDF) 06.2002
f.  Disconnects and Switches  (PDF) 06.2002
g. Shunt Capacitors (PDF) 08.1999
h. Instrument Transformers (PDF) 02.1999
i. AC Station Service (PDF) 06.1999
j. Substation Batteries and Chargers  (PDF) 04.1999
k. DC Substation Service  (PDF) 06.1999
l. Substation Operation and Maintenance (PDF) 12.2003
m. Carrier Current Line Traps  (PDF) 06.2002
n. Insulation Coordination and Surge Protection  (PDF) 06.2002
o. Relay and Control Building Requirements (PDF) 06.2004
VI. Rating Guides
a. Bare Overhead Transmission Conductor Ratings (PDF) 11.2000
b. Power Transformers (PDF) 02.1999
c. Circuit Breakers (PDF) 06.1999
d. Air Disconnect Switches (PDF) 02.1999
e. Outdoor Substation Conductor Ratings (PDF) 12.2004
f. Current Transformers (PDF) 02.1999
g. Line Traps (PDF) 08.1999
VII. Installation and Commissioning (PDF) 12.2003
VIII. Inspection, Testing and Acceptance (PDF) 12.2003
Annexes
A. System Phasing Diagrams (PDF) 01.2002
B. Definitions (PDF) 06.2002