<?xml version="1.0" encoding="UTF-8"?>
<edart xmlns:xsi="http://www.w3.org/2000/10/XMLSchema-instance">
        <generator_list>
                <gen_unit>
                        <generator_id>11</generator_id>
                        <generator_name>Earmark 1</generator_name>
                        <generator_type>Hydro</generator_type>
                        <capacity>350</capacity>
                        <mvar_ratings>
                                <Rating>
                                        <ta_id>12345</ta_id>
                                        <EMS_Equip_Name>EARMARK GEN 11 UNIT</EMS_Equip_Name>
                                        <MW_Point>125</MW_Point>
                                        <MVAR_Max>70</MVAR_Max>
                                        <MVAR_Min>-50</MVAR_Min>
                                </Rating>
                                <Rating>
                                        <ta_id>12345</ta_id>
                                        <EMS_Equip_Name>EARMARK GEN 11 UNIT</EMS_Equip_Name>
                                        <MW_Point>150</MW_Point>
                                        <MVAR_Max>60</MVAR_Max>
                                        <MVAR_Min>-40</MVAR_Min>
                                </Rating>
                                <Rating>
                                        <ta_id>12345</ta_id>
                                        <EMS_Equip_Name>EARMARK GEN 11 UNIT</EMS_Equip_Name>
                                        <MW_Point>175</MW_Point>
                                        <MVAR_Max>50</MVAR_Max>
                                        <MVAR_Min>-30</MVAR_Min>
                                </Rating>
                                <Rating>
                                        <ta_id>12346</ta_id>
                                        <EMS_Equip_Name>EARMARK GEN 12 UNIT</EMS_Equip_Name>
                                        <MW_Point>125</MW_Point>
                                        <MVAR_Max>70</MVAR_Max>
                                        <MVAR_Min>-50</MVAR_Min>
                                </Rating>
                                <Rating>
                                        <ta_id>12346</ta_id>
                                        <EMS_Equip_Name>EARMARK GEN 12 UNIT</EMS_Equip_Name>
                                        <MW_Point>150</MW_Point>
                                        <MVAR_Max>60</MVAR_Max>
                                        <MVAR_Min>-40</MVAR_Min>
                                </Rating>
                                <Rating>
                                        <ta_id>12346</ta_id>
                                        <EMS_Equip_Name>EARMARK GEN 12 UNIT</EMS_Equip_Name>
                                        <MW_Point>175</MW_Point>
                                        <MVAR_Max>50</MVAR_Max>
                                        <MVAR_Min>-30</MVAR_Min>
                                </Rating>
                        </mvar_ratings>
                </gen_unit>
                <gen_unit>
                        <generator_id>15</generator_id>
                        <generator_name>Primetime 3</generator_name>
                        <generator_type>Nug</generator_type>
                        <capacity>120</capacity>
                        <mvar_ratings>
                                <Rating>
                                        <ta_id>16345</ta_id>
                                        <EMS_Equip_Name>PRIMETIME GEN 3 UNIT</EMS_Equip_Name>
                                        <MW_Point>100</MW_Point>
                                        <MVAR_Max>70</MVAR_Max>
                                        <MVAR_Min>-50</MVAR_Min>
                                </Rating>
                                <Rating>
                                        <ta_id>16345</ta_id>
                                        <EMS_Equip_Name>PRIMETIME GEN 3 UNIT</EMS_Equip_Name>
                                        <MW_Point>120</MW_Point>
                                        <MVAR_Max>60</MVAR_Max>
                                        <MVAR_Min>-40</MVAR_Min>
                                </Rating>
                        </mvar_ratings>
                </gen_unit>
        </generator_list>
</edart>