<Contingencies Timestamp="2026-06-10T02:15:06">
  <Contingency>
    <SeqNum>10</SeqNum>
    <Name>For TT Transfer Interface Select</Name>
    <LastEdit Timestamp="2025-10-10T13:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="GREYSTON" b2="230 KV" b3="B44" />
      <ContingencyEquipment Action="CL" Type="CB" b1="GREYSTON" b2="230 KV" b3="B61" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="GREYSTON" b2="230 KV" b3="BK 1 DI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60</SeqNum>
    <Name>L69.Lewis-MossMill.0701</Name>
    <LastEdit Timestamp="2026-04-08T09:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="DT CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEWIS" b2="69 KV" b3="LEW-MOSS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSSMILL" b2="69 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSSMILL" b2="69 KV" b3="N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70</SeqNum>
    <Name>L69.Cedar-Motts.0770</Name>
    <LastEdit Timestamp="2026-01-28T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CEDAR" b2="69 KV" b3="CED-MOT5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTTS" b2="69 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80</SeqNum>
    <Name>L69.Cedar-ShipBottom.0767</Name>
    <LastEdit Timestamp="2026-01-28T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CEDAR" b2="69 KV" b3="CED-SHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB GQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHIPBOTT" b2="69 KV" b3="GCB F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHIPBOTT" b2="69 KV" b3="GCB J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90</SeqNum>
    <Name>L69.Cedar-ShipBottom.0766</Name>
    <LastEdit Timestamp="2026-01-28T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CEDAR" b2="69 KV" b3="CED-SHI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="FF CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB KM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHIPBOTT" b2="69 KV" b3="GCB C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHIPBOTT" b2="69 KV" b3="GCB E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100</SeqNum>
    <Name>L69.Cedar-Barnegate.0777</Name>
    <LastEdit Timestamp="2026-01-28T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BARNEGAT" b2="69 KV" b3="BAR-CED1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARNEGAT" b2="69 KV" b3="CB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARNEGAT" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB ES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="OCB D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>110</SeqNum>
    <Name>L69.Cedar-Barnegate.0791</Name>
    <LastEdit Timestamp="2026-01-28T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BARNEGAT" b2="69 KV" b3="BAR-CED2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARNEGAT" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARNEGAT" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB IO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>120</SeqNum>
    <Name>L69.Lewis-Absecon.0702</Name>
    <LastEdit Timestamp="2026-01-28T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ABSECON" b2="69 KV" b3="ABS-LEW1" />
      <ContingencyEquipment Action="CL" Type="CB" b1="ABSECON" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ABSECON" b2="69 KV" b3="M" />
      <ContingencyEquipment Action="S" Type="SD" b1="ABSECON" b2="69 KV" b3="SERIES1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="OCB G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>130</SeqNum>
    <Name>L69.Lewis-Higbee.0751</Name>
    <LastEdit Timestamp="2026-01-28T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGBEE" b2="69 KV" b3="OCB H" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGBEE" b2="69 KV" b3="HIG-LEWI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="OCB J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>140</SeqNum>
    <Name>L69.Lewis-Higbee.0741</Name>
    <LastEdit Timestamp="2026-01-28T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HIGBEE" b2="69 KV" b3="HIG-LEW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGBEE" b2="69 KV" b3="OCB B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="OCB S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>150</SeqNum>
    <Name>L69.Lewis-Ontario.0742</Name>
    <LastEdit Timestamp="2026-01-28T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="GCB KM" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEWIS" b2="69 KV" b3="LEW-ONT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONTARIO" b2="69 KV" b3="OCB B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>160</SeqNum>
    <Name>L69.Higbee-Ontario.0772</Name>
    <LastEdit Timestamp="2026-01-28T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HIGBEE" b2="69 KV" b3="HIG-ONT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGBEE" b2="69 KV" b3="OCB E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONTARIO" b2="69 KV" b3="OCB A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>170</SeqNum>
    <Name>L69.Mill-Marven.0749</Name>
    <LastEdit Timestamp="2026-01-28T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARVENAE" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARVENAE" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARVENAE" b2="69 KV" b3="MAR-MILL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL" b2="69 KV" b3="OCB B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>190</SeqNum>
    <Name>L69.Lewis-FAATC.0719</Name>
    <LastEdit Timestamp="2025-12-03T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAATC" b2="69 KV" b3="76462" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAATC" b2="69 KV" b3="FAA-LEW2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FAATC" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="OCB C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>200</SeqNum>
    <Name>L69.Lenox-EggHarbor.0794</Name>
    <LastEdit Timestamp="2026-01-28T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EGGHARBO" b2="69 KV" b3="A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EGGHARBO" b2="69 KV" b3="E CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EGGHARBO" b2="69 KV" b3="EGG-LEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LENOX AE" b2="69 KV" b3="OCB D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>210</SeqNum>
    <Name>L69.Monroe-WinslowA-Dacosta.0731</Name>
    <LastEdit Timestamp="2026-01-28T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DACOSTA" b2="69 KV" b3="DAC-WIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DACOSTA" b2="69 KV" b3="OCB M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="69 KV" b3="OCB A" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONR AE" b2="69 KV" b3="MON-WINA" />
      <ContingencyEquipment Action="L" Type="LN" b1="WINSLOW" b2="69 KV" b3="WIN-WINA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>220</SeqNum>
    <Name>L69.Monroe-Vineland.0711</Name>
    <LastEdit Timestamp="2026-01-28T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MONR AE" b2="69 KV" b3="MON-VINE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="69 KV" b3="OCB L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINELAND" b2="69 KV" b3="OCB U" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>230</SeqNum>
    <Name>L69.Butler-Vineland.0789</Name>
    <LastEdit Timestamp="2026-01-28T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BUTLER" b2="69 KV" b3="BUT-VIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTLER" b2="69 KV" b3="OCB M" />
      <ContingencyEquipment Action="S" Type="SD" b1="BUTLER" b2="69 KV" b3="SD789" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINELAND" b2="69 KV" b3="OCB D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>240</SeqNum>
    <Name>L69.Sherman-Vineland.0761</Name>
    <LastEdit Timestamp="2026-01-29T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERMAN" b2="69 KV" b3="OCB C" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHERMAN" b2="69 KV" b3="SHE-VIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINELAND" b2="69 KV" b3="OCB A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>250</SeqNum>
    <Name>L69.Sherman-SecondSt.0757</Name>
    <LastEdit Timestamp="2026-01-29T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SECONDST" b2="69 KV" b3="OCB H" />
      <ContingencyEquipment Action="L" Type="LN" b1="SECONDST" b2="69 KV" b3="SEC-SHE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERMAN" b2="69 KV" b3="OCB J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>260</SeqNum>
    <Name>L69.Sherman-SecondSt.0758</Name>
    <LastEdit Timestamp="2026-01-29T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SECONDST" b2="69 KV" b3="OCB K" />
      <ContingencyEquipment Action="L" Type="LN" b1="SECONDST" b2="69 KV" b3="SEC-SHE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERMAN" b2="69 KV" b3="OCB A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>270</SeqNum>
    <Name>L69.SecondStreet-WheatonTap-SouthMillville.0733</Name>
    <LastEdit Timestamp="2025-08-22T08:00:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SECONDST" b2="69 KV" b3="OCB L" />
      <ContingencyEquipment Action="L" Type="LN" b1="SECONDST" b2="69 KV" b3="SEC-WHTP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMILLVIL" b2="69 KV" b3="OCB A" />
      <ContingencyEquipment Action="L" Type="LN" b1="SMILLVIL" b2="69 KV" b3="SMI-WHTP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHEATOTP" b2="69 KV" b3="BETA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>280</SeqNum>
    <Name>L69.Butler-Lincoln.0764</Name>
    <LastEdit Timestamp="2026-01-28T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BUTLER" b2="69 KV" b3="BUT-LINC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTLER" b2="69 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN3" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN3" b2="69 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>290</SeqNum>
    <Name>L69.Newport-SouthMillville.0762</Name>
    <LastEdit Timestamp="2024-06-13T13:01:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="NEWPORT" b2="69 KV" b3="0762-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPORT" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWPORT" b2="69 KV" b3="NEW-SML" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPORT" b2="69 KV" b3="OCB H" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWPORT" b2="69 KV" b3="SILICA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMILLVIL" b2="69 KV" b3="OCB B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>300</SeqNum>
    <Name>L69.Fairton-Newport.0727</Name>
    <LastEdit Timestamp="2025-11-14T09:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FAIRTON" b2="69 KV" b3="FAI-NEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRTON" b2="69 KV" b3="OCB G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPORT" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPORT" b2="69 KV" b3="OCB G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>310</SeqNum>
    <Name>L69.Laurel-Fairton.0708</Name>
    <LastEdit Timestamp="2026-01-29T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FAIRTON" b2="69 KV" b3="FAI-LAU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRTON" b2="69 KV" b3="OCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUREL" b2="69 KV" b3="OCB E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>320</SeqNum>
    <Name>L69.CarllsCorner-Laurel.0709</Name>
    <LastEdit Timestamp="2026-01-29T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARLLS" b2="69 KV" b3="CAR-LAU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLLS" b2="69 KV" b3="OCB C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUREL" b2="69 KV" b3="OCB A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>350</SeqNum>
    <Name>L69.CarllsCorner-Sherman.0739</Name>
    <LastEdit Timestamp="2026-01-29T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARLLS" b2="69 KV" b3="CAR-SHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLLS" b2="69 KV" b3="OCB D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERMAN" b2="69 KV" b3="OCB H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>360</SeqNum>
    <Name>L69.Butler-Sherman.0778</Name>
    <LastEdit Timestamp="2026-01-29T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BUTLER" b2="69 KV" b3="BUT-SHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTLER" b2="69 KV" b3="OCB K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERMAN" b2="69 KV" b3="OCB M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>370</SeqNum>
    <Name>L69.Quinton-Roadstown.0799</Name>
    <LastEdit Timestamp="2026-01-27T10:39:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINTON" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="QUINTON" b2="69 KV" b3="QUI-ROA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROADSTOW" b2="69 KV" b3="0799DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROADSTOW" b2="69 KV" b3="B CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>390</SeqNum>
    <Name>L69.Laurel-Woodstown.0740</Name>
    <LastEdit Timestamp="2026-01-29T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAUREL" b2="69 KV" b3="LAU-WOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUREL" b2="69 KV" b3="OCB C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSTOW" b2="69 KV" b3="OCB S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>400</SeqNum>
    <Name>L69.Clayton-Woodstown.0714</Name>
    <LastEdit Timestamp="2026-01-29T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYTNAE" b2="69 KV" b3="CLA-WOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTNAE" b2="69 KV" b3="OCB E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSTOW" b2="69 KV" b3="OCB F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>410</SeqNum>
    <Name>L69.Monroe-WilliamsT-Clayton.0716</Name>
    <LastEdit Timestamp="2026-01-29T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYTNAE" b2="69 KV" b3="CLA-WIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTNAE" b2="69 KV" b3="OCB D" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONR AE" b2="69 KV" b3="MON-WIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="69 KV" b3="OCB B" />
      <ContingencyEquipment Action="L" Type="LN" b1="WILLIAMS" b2="69 KV" b3="WIL-WILT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>440</SeqNum>
    <Name>L69.ChurchTown-Salem-Woodstown.0724</Name>
    <LastEdit Timestamp="2025-12-18T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCHTO" b2="69 KV" b3="CHU-MAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="DT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="ES" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MANNMILL" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANNMILL" b2="69 KV" b3="MAN-WOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSTOW" b2="69 KV" b3="OCB W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>460</SeqNum>
    <Name>L69.Woodstown-Churchtown.0725</Name>
    <LastEdit Timestamp="2026-01-29T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCHTO" b2="69 KV" b3="CHU-WOO5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="JN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="LM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSTOW" b2="69 KV" b3="OCB E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>470</SeqNum>
    <Name>L69.Woodstown-Churchtown.0726</Name>
    <LastEdit Timestamp="2026-01-30T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCHTO" b2="69 KV" b3="CHU-WOO6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="GQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="HP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSTOW" b2="69 KV" b3="OCB R" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>480</SeqNum>
    <Name>L69.Pitman-Washington.0753</Name>
    <LastEdit Timestamp="2025-07-07T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PITMAN" b2="69 KV" b3="OCB A" />
      <ContingencyEquipment Action="L" Type="LN" b1="PITMAN" b2="69 KV" b3="PIT-WAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WASHINGT" b2="69 KV" b3="GCB D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WASHINGT" b2="69 KV" b3="GCB_E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>490</SeqNum>
    <Name>L69.Monroe-Washington.0786</Name>
    <LastEdit Timestamp="2025-07-17T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MONR AE" b2="69 KV" b3="MON-WAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="69 KV" b3="OCB U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WASHINGT" b2="69 KV" b3="GCB B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WASHINGT" b2="69 KV" b3="GCB_F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>500</SeqNum>
    <Name>L69.Monroe-Sickler.0732</Name>
    <LastEdit Timestamp="2026-01-29T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MONR AE" b2="69 KV" b3="MON-SIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="69 KV" b3="OCB G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SICKLER" b2="69 KV" b3="OCB C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>510</SeqNum>
    <Name>L69.Mickleton-River.0747</Name>
    <LastEdit Timestamp="2026-03-10T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="KK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="LL" />
      <ContingencyEquipment Action="L" Type="LN" b1="MICKLETO" b2="69 KV" b3="MIC-RIV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVER" b2="69 KV" b3="OCB B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>520</SeqNum>
    <Name>L69.Mickleton-ValeroTap-Paulsboro.0746</Name>
    <LastEdit Timestamp="2025-03-26T10:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MICKLETO" b2="69 KV" b3="MIC-VALT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="NN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="PP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAULSBRO" b2="69 KV" b3="OCB O" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAULSBRO" b2="69 KV" b3="PAU-VALT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALERO" b2="69 KV" b3="OCB 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="VALERO" b2="69 KV" b3="VAL-VALT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>530</SeqNum>
    <Name>L69.Paulsboro-Valero.0774</Name>
    <LastEdit Timestamp="2025-05-22T13:41:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PAULSBRO" b2="69 KV" b3="OCB Q" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAULSBRO" b2="69 KV" b3="PAU-VAPK" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VALERO" b2="69 KV" b3="LOAD3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALERO" b2="69 KV" b3="OCB 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="VALERO" b2="69 KV" b3="VAL-VAPK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>550</SeqNum>
    <Name>L69.Oldman-Churchtown.0710</Name>
    <LastEdit Timestamp="2025-11-04T15:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLDMAN" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCHTO" b2="69 KV" b3="CHU-OLDM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>560</SeqNum>
    <Name>L69.Monsanto-BurlTap-River.0763</Name>
    <LastEdit Timestamp="2026-01-27T10:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BURL_TAP" b2="69 KV" b3="BUR-RIVE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BURL_TAP" b2="69 KV" b3="BUR_LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURL_TAP" b2="69 KV" b3="BUR-MONS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONSANTO" b2="69 KV" b3="OCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVER" b2="69 KV" b3="OCB C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>580</SeqNum>
    <Name>L138.England-Scull-Mill.1407</Name>
    <LastEdit Timestamp="2026-01-29T14:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-G" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENGLAND" b2="138 KV" b3="ENG-SCU7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILL" b2="138 KV" b3="MIL-SC_7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL" b2="138 KV" b3="O" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCULL" b2="138 KV" b3="BUS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>610</SeqNum>
    <Name>L138.Merion-Corson.1411 + LoadTransfer</Name>
    <LastEdit Timestamp="2024-05-02T11:21:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORSON" b2="138 KV" b3="COR-MER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORSON" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERION" b2="138 KV" b3="GCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERION" b2="138 KV" b3="GCB B" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MERION" b2="138 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>620</SeqNum>
    <Name>L138.England-Merion.1401</Name>
    <LastEdit Timestamp="2025-09-08T08:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-C" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENGLAND" b2="138 KV" b3="ENG-MER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERION" b2="138 KV" b3="GCB B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERION" b2="138 KV" b3="GCB C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>630</SeqNum>
    <Name>L138.Corson-MiddleTap-England.1403</Name>
    <LastEdit Timestamp="2025-05-20T11:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORSON" b2="138 KV" b3="COR-MDT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORSON" b2="138 KV" b3="OCB R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-D" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENGLAND" b2="138 KV" b3="ENG-MDT" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDD AE" b2="138 KV" b3="MID #4" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDD AE" b2="138 KV" b3="MID-MDT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLTAP" b2="138 KV" b3="OCB G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>640</SeqNum>
    <Name>L138.Corson-Middle.1412</Name>
    <LastEdit Timestamp="2025-11-26T11:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORSON" b2="138 KV" b3="COR-MID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORSON" b2="138 KV" b3="OCB Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD AE" b2="138 KV" b3="R" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>650</SeqNum>
    <Name>L138.Middle-MiddleTap.1413 + 138/69.Middle.T4</Name>
    <LastEdit Timestamp="2025-05-20T11:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MIDD AE" b2="138 KV" b3="MID #4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD AE" b2="69 KV" b3="XFMROCBL" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDD AE" b2="138 KV" b3="MID-MDT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLTAP" b2="138 KV" b3="OCB G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>660</SeqNum>
    <Name>L138.Corson-Union.1402</Name>
    <LastEdit Timestamp="2026-01-29T14:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORSON" b2="138 KV" b3="COR-UNI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORSON" b2="138 KV" b3="OCB S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNION" b2="138 KV" b3="C CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>670</SeqNum>
    <Name>L138.Corson-Dennis.1417</Name>
    <LastEdit Timestamp="2025-09-08T08:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORSON" b2="138 KV" b3="COR-DEN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORSON" b2="138 KV" b3="OCB-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="138 KV" b3="GCB A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>680</SeqNum>
    <Name>L138.Cumberland-Union.1416</Name>
    <LastEdit Timestamp="2026-01-29T14:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="138 KV" b3="BUSGCBF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="138 KV" b3="BUSGCBH" />
      <ContingencyEquipment Action="L" Type="LN" b1="CUMB AE" b2="138 KV" b3="CUM-UNI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNION" b2="138 KV" b3="D CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>690</SeqNum>
    <Name>L138.Cumberland-Sherman.1415</Name>
    <LastEdit Timestamp="2026-01-29T14:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="138 KV" b3="BUSGCBD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="138 KV" b3="BUSGCBE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CUMB AE" b2="138 KV" b3="CUM-SHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERMAN" b2="138 KV" b3="OCB S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>710</SeqNum>
    <Name>230/138.Cumberland.T2</Name>
    <LastEdit Timestamp="2024-12-12T11:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="230 KV" b3="BUSGCBB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="230 KV" b3="BUSGCBC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="138 KV" b3="BUSGCBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="138 KV" b3="BUSGCBF" />
      <ContingencyEquipment Action="X" Type="XF" b1="CUMB AE" b2="230 KV" b3="CUMB #2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>720</SeqNum>
    <Name>Cumberland.CT1</Name>
    <LastEdit Timestamp="2026-01-29T14:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CUMB AE" b2="13.8 KV" b3="AUXLD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="138 KV" b3="BUSGCBH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="138 KV" b3="BUSGCBL" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CUMB AE" b2="13.8 KV" b3="CUMBCT" />
      <ContingencyEquipment Action="X" Type="XF" b1="CUMB AE" b2="138 KV" b3="GSU1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>760</SeqNum>
    <Name>L138.Churchtown-UpperPittsgrove.1405</Name>
    <LastEdit Timestamp="2026-02-11T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="138 KV" b3="BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCHTO" b2="138 KV" b3="CHU-UPP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERPIT" b2="138 KV" b3="OCBE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>770</SeqNum>
    <Name>L138.Landis-UpperPittsgrove.1406</Name>
    <LastEdit Timestamp="2025-11-30T18:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDIS" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANDIS" b2="138 KV" b3="LAN-UPP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDIS" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERPIT" b2="138 KV" b3="OCBA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>790</SeqNum>
    <Name>L138.Monroe-Franklin.1420</Name>
    <LastEdit Timestamp="2026-01-29T14:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKAE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKAE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKAE" b2="138 KV" b3="FRA-MONR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="138 KV" b3="XFMROCBH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="138 KV" b3="XFMROCBP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>800</SeqNum>
    <Name>L138.Landis-Minotola.1409</Name>
    <LastEdit Timestamp="2026-01-29T14:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LANDIS" b2="138 KV" b3="LAN-MIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDIS" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDIS" b2="138 KV" b3="W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINOTOLA" b2="138 KV" b3="H CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINOTOLA" b2="138 KV" b3="M CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>810</SeqNum>
    <Name>230/69.Churchtown.T1</Name>
    <LastEdit Timestamp="2026-01-29T14:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CHURCHTO" b2="230 KV" b3="CRCH #1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="230 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="230 KV" b3="U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="XFMRGCBD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>820</SeqNum>
    <Name>138/69.Lewis.T1</Name>
    <LastEdit Timestamp="2026-01-29T14:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LEWIS" b2="138 KV" b3="LEW #1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="138 KV" b3="XFMRABSM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="XFMROCBD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>830</SeqNum>
    <Name>138/69.Lewis.T3</Name>
    <LastEdit Timestamp="2026-01-29T14:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="HP CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LEWIS" b2="138 KV" b3="IO DIS" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEWIS" b2="138 KV" b3="LEW #3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>840</SeqNum>
    <Name>138/69.Lewis.T2</Name>
    <LastEdit Timestamp="2026-01-30T11:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LEWIS" b2="138 KV" b3="LEW #2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="138 KV" b3="XFMRABSN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="XFMROCBE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>850</SeqNum>
    <Name>138/69.Corson.T1</Name>
    <LastEdit Timestamp="2026-01-29T14:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CORSON" b2="138 KV" b3="BUSOCBT" />
      <ContingencyEquipment Action="X" Type="XF" b1="CORSON" b2="138 KV" b3="CORS #1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORSON" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORSON" b2="69 KV" b3="XFMROCBJ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>860</SeqNum>
    <Name>138/69.Corson.T2</Name>
    <LastEdit Timestamp="2026-01-29T14:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CORSON" b2="138 KV" b3="CORS #2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CORSON" b2="138 KV" b3="DIS-F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORSON" b2="69 KV" b3="XFMROCBA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>890</SeqNum>
    <Name>230/138.Churchtown.T4</Name>
    <LastEdit Timestamp="2026-02-10T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="230 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="138 KV" b3="BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="230 KV" b3="E" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHURCHTO" b2="230 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>910</SeqNum>
    <Name>138/69.Sherman.T2</Name>
    <LastEdit Timestamp="2026-01-30T11:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SHERMAN" b2="138 KV" b3="SHER #2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERMAN" b2="69 KV" b3="XFMROCBD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERMAN" b2="138 KV" b3="XFMRQBV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>920</SeqNum>
    <Name>138/69.Sherman.T3</Name>
    <LastEdit Timestamp="2026-01-30T11:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SHERMAN" b2="138 KV" b3="SHER #3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERMAN" b2="69 KV" b3="XFMROCBL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERMAN" b2="138 KV" b3="XFMRQBW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>930</SeqNum>
    <Name>L69.Mickleton-Mantua.0748</Name>
    <LastEdit Timestamp="2026-01-16T13:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MANTUA" b2="69 KV" b3="MAN-MIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANTUA" b2="69 KV" b3="OCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="QQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="RR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>940</SeqNum>
    <Name>L69.Cardiff-Absecon-Lewis.0781</Name>
    <LastEdit Timestamp="2025-11-03T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="ABSECON" b2="69 KV" b3="0781-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ABSECON" b2="69 KV" b3="ABS-CAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="ABSECON" b2="69 KV" b3="ABS-LEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ABSECON" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="CL" Type="CB" b1="ABSECON" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="69 KV" b3="OCB G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="GQ CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>950</SeqNum>
    <Name>L69.Cardiff-Mill</Name>
    <LastEdit Timestamp="2026-01-30T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARDIFF" b2="69 KV" b3="CAR-MILL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="69 KV" b3="GCB F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL" b2="69 KV" b3="XFMROCBJ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>970</SeqNum>
    <Name>Sherman.CT1</Name>
    <LastEdit Timestamp="2026-01-30T12:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHERMAN" b2="13.8 KV" b3="AUXLD1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SHERMAN" b2="13.8 KV" b3="CT 1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHERMAN" b2="138 KV" b3="GSU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERMAN" b2="138 KV" b3="OCB BV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>990</SeqNum>
    <Name>L230.Steele-Vienna.23085</Name>
    <LastEdit Timestamp="2026-02-11T10:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="230 KV" b3="252" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="230 KV" b3="9230" />
      <ContingencyEquipment Action="L" Type="LN" b1="STEELE" b2="230 KV" b3="STE-VIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="230 KV" b3="230" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1000</SeqNum>
    <Name>230/138.CedarCreek.AT20</Name>
    <LastEdit Timestamp="2026-01-30T11:32:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCRE" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCRE" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCRE" b2="230 KV" b3="233" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCRE" b2="230 KV" b3="234" />
      <ContingencyEquipment Action="X" Type="XF" b1="CEDARCRE" b2="230 KV" b3="AT20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1010</SeqNum>
    <Name>230/138.Milford.AT20</Name>
    <LastEdit Timestamp="2026-01-30T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="138 KV" b3="8610" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="138 KV" b3="8640" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="230 KV" b3="9380" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="230 KV" b3="9390" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILFORD" b2="230 KV" b3="AT20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1020</SeqNum>
    <Name>230/138.Vienna.AT20</Name>
    <LastEdit Timestamp="2025-10-30T15:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="VIENNA" b2="138 KV" b3="13710" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="230 KV" b3="230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="138 KV" b3="8130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="138 KV" b3="8140" />
      <ContingencyEquipment Action="X" Type="XF" b1="VIENNA" b2="230 KV" b3="AT20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1040</SeqNum>
    <Name>L138.Church-OilCity-Steele.13701</Name>
    <LastEdit Timestamp="2026-01-30T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="138 KV" b3="8430" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCH" b2="138 KV" b3="CHU-OIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OILCITY" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="OILCITY" b2="138 KV" b3="OIL-STE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="8290" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1050</SeqNum>
    <Name>L138.IndianRiver-Frankford-Bishop.13719</Name>
    <LastEdit Timestamp="2026-01-30T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP" b2="138 KV" b3="164" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP" b2="138 KV" b3="165" />
      <ContingencyEquipment Action="L" Type="LN" b1="BISHOP" b2="138 KV" b3="BIS-FRA" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKFOR" b2="138 KV" b3="FRA-IND" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRANKFOR" b2="138 KV" b3="FRANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="8040" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="8050" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1060</SeqNum>
    <Name>L138.Bishop-OceanBay.13786</Name>
    <LastEdit Timestamp="2026-01-30T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP" b2="138 KV" b3="161" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP" b2="138 KV" b3="166" />
      <ContingencyEquipment Action="L" Type="LN" b1="BISHOP" b2="138 KV" b3="BIS-OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANBAY" b2="138 KV" b3="172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANBAY" b2="138 KV" b3="173" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1070</SeqNum>
    <Name>L138.Bishop-Worcester.13779</Name>
    <LastEdit Timestamp="2026-02-11T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP" b2="138 KV" b3="162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP" b2="138 KV" b3="164" />
      <ContingencyEquipment Action="L" Type="LN" b1="BISHOP" b2="138 KV" b3="BIS-WOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="138 KV" b3="195" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1080</SeqNum>
    <Name>L138.IndianRiver-Nelson.13703</Name>
    <LastEdit Timestamp="2026-01-30T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="8060" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="8070" />
      <ContingencyEquipment Action="L" Type="LN" b1="INDIANRI" b2="138 KV" b3="IND-NEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="138 KV" b3="152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="138 KV" b3="155" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1090</SeqNum>
    <Name>L138.IndianRiver-Omar-Roxana.13745</Name>
    <LastEdit Timestamp="2025-02-25T19:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="8000" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="8010" />
      <ContingencyEquipment Action="L" Type="LN" b1="INDIANRI" b2="138 KV" b3="IND-OMA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OMAR" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXANA" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXANA" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="L" Type="LN" b1="OMAR" b2="138 KV" b3="OMA-ROXA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1100</SeqNum>
    <Name>L138.Bethany-138thSt.13732</Name>
    <LastEdit Timestamp="2026-01-30T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="138 KV" b3="132CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHANY" b2="138 KV" b3="BET-ST1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ST138" b2="138 KV" b3="130" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1110</SeqNum>
    <Name>L138.Nelson-Vienna.13707</Name>
    <LastEdit Timestamp="2026-01-30T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="138 KV" b3="150" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="138 KV" b3="154" />
      <ContingencyEquipment Action="L" Type="LN" b1="NELSON" b2="138 KV" b3="NEL-VIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="138 KV" b3="8150" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="138 KV" b3="8180" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1120</SeqNum>
    <Name>Nelson.SVC</Name>
    <LastEdit Timestamp="2025-02-14T14:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="138 KV" b3="151" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="138 KV" b3="155" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NELSON" b2="138 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1130</SeqNum>
    <Name>L138.Steele-Hillsboro-WyeMills.13761/13788</Name>
    <LastEdit Timestamp="2026-01-30T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSBRO" b2="138 KV" b3="150CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLSBRO" b2="138 KV" b3="HIL-STE" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLSBRO" b2="138 KV" b3="HIL-WYE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILLSBRO" b2="138 KV" b3="HLSBRO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="8260" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="138 KV" b3="130 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="138 KV" b3="8680" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1140</SeqNum>
    <Name>L138.NewChurch-PineyGrove.13764</Name>
    <LastEdit Timestamp="2026-01-30T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCHURC" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCHURC" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWCHURC" b2="138 KV" b3="NEW-PIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="138 KV" b3="8880" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1150</SeqNum>
    <Name>L138.NewChurch-OakHall.13765</Name>
    <LastEdit Timestamp="2026-02-02T12:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCHURC" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCHURC" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWCHURC" b2="138 KV" b3="NEW-OAK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="183" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="188" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1160</SeqNum>
    <Name>L138.NewChurch-OakHall.13763</Name>
    <LastEdit Timestamp="2026-02-02T12:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCHURC" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCHURC" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWCHURC" b2="138 KV" b3="NEW-OAK3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="185" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="187" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1170</SeqNum>
    <Name>NewChurch.CT1-2</Name>
    <LastEdit Timestamp="2026-02-03T15:09:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCHURC" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCHURC" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWCHURC" b2="13 KV" b3="CT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWCHURC" b2="13 KV" b3="CT2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWCHURC" b2="13 KV" b3="SS_1_2" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWCHURC" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="S" Type="SD" b1="NEWCHURC" b2="138 KV" b3="T1T2 SD" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWCHURC" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1180</SeqNum>
    <Name>NewChurch.CT3-4</Name>
    <LastEdit Timestamp="2026-02-03T15:09:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCHURC" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCHURC" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWCHURC" b2="13 KV" b3="CT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWCHURC" b2="13 KV" b3="CT4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWCHURC" b2="13 KV" b3="SS_3_4" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWCHURC" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="S" Type="SD" b1="NEWCHURC" b2="138 KV" b3="T3T4 SD" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWCHURC" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1190</SeqNum>
    <Name>NewChurch.CT5-7</Name>
    <LastEdit Timestamp="2026-02-02T12:38:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCHURC" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCHURC" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWCHURC" b2="13 KV" b3="CT5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWCHURC" b2="13 KV" b3="CT6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWCHURC" b2="13 KV" b3="CT7" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWCHURC" b2="138 KV" b3="T5" />
      <ContingencyEquipment Action="S" Type="SD" b1="NEWCHURC" b2="138 KV" b3="T5-7 SD" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWCHURC" b2="138 KV" b3="T6" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWCHURC" b2="138 KV" b3="T7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1200</SeqNum>
    <Name>L138.Cheswold-Jones-Clayton.13770</Name>
    <LastEdit Timestamp="2025-09-16T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWOLD" b2="138 KV" b3="8220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWOLD" b2="138 KV" b3="8230" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESWOLD" b2="138 KV" b3="CHE-JON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTON" b2="138 KV" b3="8270" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTON" b2="138 KV" b3="8280" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYTON" b2="138 KV" b3="CLA-JON" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="JONES" b2="138 KV" b3="JONES" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1210</SeqNum>
    <Name>L138.NorthSeaford-SouthHarrington.13771</Name>
    <LastEdit Timestamp="2026-02-02T12:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="138 KV" b3="8380" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="138 KV" b3="8390" />
      <ContingencyEquipment Action="L" Type="LN" b1="NSEAFORD" b2="138 KV" b3="NSE-SHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="138 KV" b3="8340" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="138 KV" b3="8350" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1220</SeqNum>
    <Name>L138.Felton-SouthHarrington.13709</Name>
    <LastEdit Timestamp="2026-01-30T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FELTON" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FELTON" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="L" Type="LN" b1="FELTON" b2="138 KV" b3="FEL-SHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="138 KV" b3="8360" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="138 KV" b3="8370" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1240</SeqNum>
    <Name>L138.Cheswold-Felton.13704</Name>
    <LastEdit Timestamp="2026-01-30T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWOLD" b2="138 KV" b3="8240" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWOLD" b2="138 KV" b3="8250" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESWOLD" b2="138 KV" b3="CHE-FEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FELTON" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FELTON" b2="138 KV" b3="135" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1250</SeqNum>
    <Name>L138.Loretto-PineyGrove.13777</Name>
    <LastEdit Timestamp="2026-02-02T12:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LORETTO" b2="138 KV" b3="8460" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORETTO" b2="138 KV" b3="8470" />
      <ContingencyEquipment Action="L" Type="LN" b1="LORETTO" b2="138 KV" b3="LOR-PIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="138 KV" b3="8860" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="138 KV" b3="8880" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1260</SeqNum>
    <Name>L138.Loretto-Vienna.13780</Name>
    <LastEdit Timestamp="2024-10-23T08:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LORETTO" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORETTO" b2="138 KV" b3="8460" />
      <ContingencyEquipment Action="L" Type="LN" b1="LORETTO" b2="138 KV" b3="LOR-VIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="138 KV" b3="8110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="138 KV" b3="8160" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1270</SeqNum>
    <Name>L138.KingsCreek-Loretto.13713</Name>
    <LastEdit Timestamp="2026-01-30T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGSCRK" b2="138 KV" b3="KIN-LOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORETTO" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORETTO" b2="138 KV" b3="8410" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1280</SeqNum>
    <Name>138/69.KingsCreek.AT1</Name>
    <LastEdit Timestamp="2025-04-10T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="69 KV" b3="61CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="69 KV" b3="62CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="KINGSCRK" b2="138 KV" b3="AT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1290</SeqNum>
    <Name>L138.KingsCreek-Costen-Pocomoke.13714</Name>
    <LastEdit Timestamp="2026-01-30T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COSTEN" b2="138 KV" b3="COS-KIN" />
      <ContingencyEquipment Action="L" Type="LN" b1="COSTEN" b2="138 KV" b3="COS-POC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COSTEN" b2="138 KV" b3="COSTEN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COSTEN" b2="138 KV" b3="COSTENSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCOMOKE" b2="138 KV" b3="132 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1300</SeqNum>
    <Name>L138.Edgemoor-Christiana.13805</Name>
    <LastEdit Timestamp="2026-01-30T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHR138" b2="138 KV" b3="CHR-EDG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="3-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1330</SeqNum>
    <Name>L138.ChapelStreet-Harmony.13821</Name>
    <LastEdit Timestamp="2026-01-30T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAPELST" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAPELST" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAPELST" b2="138 KV" b3="CHA-HAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="132" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1340</SeqNum>
    <Name>L138.ChapelStreet-Keeney.13819/20</Name>
    <LastEdit Timestamp="2026-01-30T11:35:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAPELST" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAPELST" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHAPELST" b2="138 KV" b3="DUM6" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHAPELST" b2="138 KV" b3="DUM7" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHAPELST" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHAPELST" b2="138 KV" b3="T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAPELST" b2="138 KV" b3="CHA-KEE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1350</SeqNum>
    <Name>L138.Harmony-Kiamensi.13828</Name>
    <LastEdit Timestamp="2026-01-30T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARMONY" b2="138 KV" b3="HAR-KIA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="137" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="138" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1360</SeqNum>
    <Name>L138.Hockesin-Kiamensi.13838</Name>
    <LastEdit Timestamp="2026-01-30T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOCKESIN" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOCKESIN" b2="138 KV" b3="HOC-KIA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="132" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1370</SeqNum>
    <Name>L138.Hockesin-Valley-Mer-Milltown.13835/7</Name>
    <LastEdit Timestamp="2026-01-30T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOCKESIN" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOCKESIN" b2="138 KV" b3="HOC-VAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MERMAID" b2="138 KV" b3="LOADT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERMAID" b2="138 KV" b3="MER-MIL" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERMAID" b2="138 KV" b3="MER-VAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLTOWN" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLTOWN" b2="138 KV" b3="134" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1380</SeqNum>
    <Name>L138.BasinRoad-Bear.13816</Name>
    <LastEdit Timestamp="2026-01-30T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="L" Type="LN" b1="BASINRD" b2="138 KV" b3="BAS-BEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAR DPL" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAR DPL" b2="138 KV" b3="135" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1390</SeqNum>
    <Name>L138.BasinRoad-Kiamensi.13813</Name>
    <LastEdit Timestamp="2026-01-30T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="L" Type="LN" b1="BASINRD" b2="138 KV" b3="BAS-KIA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="140" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="141" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1400</SeqNum>
    <Name>L138.BasinRoad-NewCastle.13815</Name>
    <LastEdit Timestamp="2025-05-22T13:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="L" Type="LN" b1="BASINRD" b2="138 KV" b3="BAS-NEW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="138 KV" b3="136" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1410</SeqNum>
    <Name>L138.Bear-SunsetLake.13843</Name>
    <LastEdit Timestamp="2026-01-30T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAR DPL" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAR DPL" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAR DPL" b2="138 KV" b3="BEA-SUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNSETLA" b2="138 KV" b3="132 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNSETLA" b2="138 KV" b3="133 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1420</SeqNum>
    <Name>L138.Glasgow-MtPleasant.13801</Name>
    <LastEdit Timestamp="2026-02-02T12:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLASGOW" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLASGOW" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLASGOW" b2="138 KV" b3="GLA-MTP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTPLEASN" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTPLEASN" b2="138 KV" b3="136" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1430</SeqNum>
    <Name>L138.Glasgow-Keeney.13809</Name>
    <LastEdit Timestamp="2026-02-02T12:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLASGOW" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLASGOW" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLASGOW" b2="138 KV" b3="GLA-KEE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="137" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="138" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1440</SeqNum>
    <Name>L138.Cecil-Glasgow.13810</Name>
    <LastEdit Timestamp="2026-02-11T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CECIL" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CECIL" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="L" Type="LN" b1="CECIL" b2="138 KV" b3="CEC-GLA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLASGOW" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLASGOW" b2="138 KV" b3="134" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1450</SeqNum>
    <Name>L138.CedarCreek-Clayton.13832</Name>
    <LastEdit Timestamp="2026-02-02T12:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCRE" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCRE" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARCRE" b2="138 KV" b3="CED-CLA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTON" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTON" b2="138 KV" b3="8290" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1460</SeqNum>
    <Name>L138.Church-Townsend.13833</Name>
    <LastEdit Timestamp="2026-02-02T12:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="138 KV" b3="8420" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCH" b2="138 KV" b3="CHU-TOW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWNSEND" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWNSEND" b2="138 KV" b3="138" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1470</SeqNum>
    <Name>138/69.Loretto.AT1&amp;2</Name>
    <LastEdit Timestamp="2026-02-02T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LORETTO" b2="69 KV" b3="7430" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORETTO" b2="69 KV" b3="7440" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORETTO" b2="138 KV" b3="8410" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORETTO" b2="138 KV" b3="8470" />
      <ContingencyEquipment Action="X" Type="XF" b1="LORETTO" b2="138 KV" b3="AT1" />
      <ContingencyEquipment Action="X" Type="XF" b1="LORETTO" b2="138 KV" b3="AT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1480</SeqNum>
    <Name>138/69.Cheswold.AT1</Name>
    <LastEdit Timestamp="2025-09-08T08:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWOLD" b2="138 KV" b3="130 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWOLD" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWOLD" b2="138 KV" b3="8250" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESWOLD" b2="138 KV" b3="AT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1490</SeqNum>
    <Name>138/69.Easton.AT1</Name>
    <LastEdit Timestamp="2025-09-08T08:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="138 KV" b3="165" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="69 KV" b3="7410" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="69 KV" b3="7420" />
      <ContingencyEquipment Action="X" Type="XF" b1="EASTON" b2="138 KV" b3="AT-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1500</SeqNum>
    <Name>138/69.Edgemoor.AT1&amp;AT2</Name>
    <LastEdit Timestamp="2025-01-15T17:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="69 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="69 KV" b3="2-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="3-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="3-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="138 KV" b3="AT1" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="138 KV" b3="AT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1510</SeqNum>
    <Name>138/69.NorthSeaford.AT1</Name>
    <LastEdit Timestamp="2026-02-02T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="69 KV" b3="7340" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="69 KV" b3="7350" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="138 KV" b3="8370" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="138 KV" b3="8380" />
      <ContingencyEquipment Action="X" Type="XF" b1="NSEAFORD" b2="138 KV" b3="AT-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1520</SeqNum>
    <Name>138/69.NorthSeaford.AT2</Name>
    <LastEdit Timestamp="2026-02-02T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="69 KV" b3="7320" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="138 KV" b3="8390" />
      <ContingencyEquipment Action="X" Type="XF" b1="NSEAFORD" b2="138 KV" b3="AT-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1530</SeqNum>
    <Name>138/69.Nelson.AT1 + Nelson.69.Cap1</Name>
    <LastEdit Timestamp="2026-02-02T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="138 KV" b3="152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="138 KV" b3="153" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="69 KV" b3="74" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="69 KV" b3="77" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="69 KV" b3="80" />
      <ContingencyEquipment Action="X" Type="XF" b1="NELSON" b2="138 KV" b3="AT1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NELSON" b2="69 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1540</SeqNum>
    <Name>138/69.OakHall.AT1</Name>
    <LastEdit Timestamp="2024-11-22T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="181" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="186" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="69 KV" b3="7220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="69 KV" b3="7240" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKHALL" b2="138 KV" b3="AT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1550</SeqNum>
    <Name>138/69.OakHall.AT2</Name>
    <LastEdit Timestamp="2024-11-22T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="184" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="185" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="69 KV" b3="7270" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="69 KV" b3="7290" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKHALL" b2="138 KV" b3="AT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1560</SeqNum>
    <Name>138/69.PineyGrove.AT1</Name>
    <LastEdit Timestamp="2026-02-02T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="69 KV" b3="7920" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="69 KV" b3="7960" />
      <ContingencyEquipment Action="X" Type="XF" b1="PINEYGRO" b2="138 KV" b3="AT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1570</SeqNum>
    <Name>138/69.SouthHarrington.AT1</Name>
    <LastEdit Timestamp="2026-02-11T09:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="69 KV" b3="7260" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="69 KV" b3="7270" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="138 KV" b3="8340" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="138 KV" b3="8370" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHARRING" b2="138 KV" b3="AT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1580</SeqNum>
    <Name>138/69.Vienna.AT1</Name>
    <LastEdit Timestamp="2026-02-02T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="69 KV" b3="7710" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="138 KV" b3="8120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="138 KV" b3="8150" />
      <ContingencyEquipment Action="X" Type="XF" b1="VIENNA" b2="138 KV" b3="AT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1590</SeqNum>
    <Name>138/69.Vienna.AT2</Name>
    <LastEdit Timestamp="2026-02-02T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="69 KV" b3="7720" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="138 KV" b3="8160" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="138 KV" b3="8170" />
      <ContingencyEquipment Action="X" Type="XF" b1="VIENNA" b2="138 KV" b3="AT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1600</SeqNum>
    <Name>138/69.WyeMills.AT1</Name>
    <LastEdit Timestamp="2026-02-02T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="138 KV" b3="131 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="138 KV" b3="132 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="7550" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="7560" />
      <ContingencyEquipment Action="X" Type="XF" b1="WYEMILLS" b2="138 KV" b3="AT-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1610</SeqNum>
    <Name>L69.Fruitland-Pemberton-NorthSalisbury.6701</Name>
    <LastEdit Timestamp="2026-02-02T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRUITLAN" b2="69 KV" b3="7550" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRUITLAN" b2="69 KV" b3="FRT-PEM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSALISBU" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NSALISBU" b2="69 KV" b3="6718_BT" />
      <ContingencyEquipment Action="L" Type="LN" b1="NSALISBU" b2="69 KV" b3="NSA-PEM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEMBERTO" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEMBERTO" b2="69 KV" b3="T-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1620</SeqNum>
    <Name>L69.Todd-Vienna.6702</Name>
    <LastEdit Timestamp="2026-04-14T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TODD" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODD" b2="69 KV" b3="7350" />
      <ContingencyEquipment Action="L" Type="LN" b1="TODD" b2="69 KV" b3="TOD-VIEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="69 KV" b3="1200" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="69 KV" b3="500" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1630</SeqNum>
    <Name>DTX69.Loretto-Princess.6756.PRNCSS</Name>
    <LastEdit Timestamp="2025-12-01T13:54:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LORETTO" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORETTO" b2="69 KV" b3="7450" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LORETTO" b2="69 KV" b3="PRNCSS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1640</SeqNum>
    <Name>L69.Blanco-NewMeredith-Kent.6704</Name>
    <LastEdit Timestamp="2025-05-13T10:57:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLANCO" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLANCO" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLANCO" b2="69 KV" b3="BLA-NEWM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="7860" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="7870" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENT" b2="69 KV" b3="KEN-NME" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWMERED" b2="69 KV" b3="N-MERD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1650</SeqNum>
    <Name>L69.Laurel-Sharptown-Vienna.6705</Name>
    <LastEdit Timestamp="2026-02-02T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAURELDP" b2="69 KV" b3="6705-280" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAURELDP" b2="69 KV" b3="LAU-SHA" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHARP" b2="69 KV" b3="SHA-VIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHARP" b2="69 KV" b3="SHARP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="69 KV" b3="288" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1660</SeqNum>
    <Name>L69.Laurel-Short-Nelson.6706</Name>
    <LastEdit Timestamp="2026-02-02T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAURELDP" b2="69 KV" b3="6706-350" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAURELDP" b2="69 KV" b3="LAU-SHO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="69 KV" b3="76" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="69 KV" b3="77" />
      <ContingencyEquipment Action="L" Type="LN" b1="NELSON" b2="69 KV" b3="NEL-SHO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHORT" b2="69 KV" b3="SHORT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1670</SeqNum>
    <Name>L69.Easton-EastonTap-Muni-Longwood-WyeMills.6707</Name>
    <LastEdit Timestamp="2025-04-28T15:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="69 KV" b3="7450" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTON" b2="69 KV" b3="EAS-EAT" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTONTP" b2="69 KV" b3="EAT-LON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTONTP" b2="69 KV" b3="SW_TAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EMUNI" b2="69 KV" b3="3610_CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTONTP" b2="69 KV" b3="EAT-EMU" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONGWOOD" b2="69 KV" b3="LON-WYE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LONGWOOD" b2="69 KV" b3="LONGWD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="7510" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="7570" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1680</SeqNum>
    <Name>L69.Hebron-Mardela-Vienna.6708</Name>
    <LastEdit Timestamp="2026-02-10T08:31:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRON" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEBRON" b2="69 KV" b3="HEB-MAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARDELA" b2="69 KV" b3="MAR-VIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARDELA" b2="69 KV" b3="MARREA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="69 KV" b3="62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1690</SeqNum>
    <Name>L69.Church-IBCorners-Price-WyeMills.6710</Name>
    <LastEdit Timestamp="2025-12-26T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="7240" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="7250" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCH" b2="69 KV" b3="CHU-IBC" />
      <ContingencyEquipment Action="L" Type="LN" b1="IBCORN" b2="69 KV" b3="IBC-PRI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IBCORN" b2="69 KV" b3="IBCORN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PRICE" b2="69 KV" b3="CHUHILSP" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRICE" b2="69 KV" b3="PRI-WYEM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PRICE" b2="69 KV" b3="PRICE T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="7540" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="7550" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1700</SeqNum>
    <Name>L69.Fruitland-Loretto.6711</Name>
    <LastEdit Timestamp="2026-02-02T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRUITLAN" b2="69 KV" b3="7500" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRUITLAN" b2="69 KV" b3="FRT-LOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORETTO" b2="69 KV" b3="7430" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORETTO" b2="69 KV" b3="7450" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1710</SeqNum>
    <Name>L69.Stockton-Signpost-Wattsville.6712</Name>
    <LastEdit Timestamp="2024-10-16T13:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SIGNPOST" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="SIGNPOST" b2="69 KV" b3="SGP-STO" />
      <ContingencyEquipment Action="L" Type="LN" b1="SIGNPOST" b2="69 KV" b3="SGP-WAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STOCKTON" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="69 KV" b3="61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1720</SeqNum>
    <Name>L69.Easton-TrappeTap-Talbt-Tanyd-Preston-Todd.6716</Name>
    <LastEdit Timestamp="2025-06-23T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="69 KV" b3="7410" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="69 KV" b3="7460" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="69 KV" b3="7480" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTON" b2="69 KV" b3="EAS-TRA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="EASTON" b2="69 KV" b3="EASTON" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRESTON" b2="69 KV" b3="PRE-TAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRESTON" b2="69 KV" b3="PRE-TOD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PRESTON" b2="69 KV" b3="PRSTON" />
      <ContingencyEquipment Action="L" Type="LN" b1="TALBOT" b2="69 KV" b3="TAL-TAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="TALBOT" b2="69 KV" b3="TAL-TRA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TALBOT" b2="69 KV" b3="TALBOT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TANYARD" b2="69 KV" b3="TANYRD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODD" b2="69 KV" b3="7330" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODD" b2="69 KV" b3="7380" />
      <ContingencyEquipment Action="S" Type="SD" b1="TRAPPETP" b2="69 KV" b3="DUMTRAP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRAPPETP" b2="69 KV" b3="T4LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRAPPETP" b2="69 KV" b3="TRAPPE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1730</SeqNum>
    <Name>L69.OakHall-Wattsvl.6717 + 69/25.OakHall.T2(N.O)</Name>
    <LastEdit Timestamp="2026-05-29T12:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="OAKHALL" b2="25 KV" b3="3239" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="69 KV" b3="7240" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="69 KV" b3="7270" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKHALL" b2="69 KV" b3="OAK-WAT" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKHALL" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="69 KV" b3="7630" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="69 KV" b3="7650" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1740</SeqNum>
    <Name>L69.Tasley-BelleHaven-Kellam.6703</Name>
    <LastEdit Timestamp="2025-05-16T12:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELLEHAV" b2="69 KV" b3="BEL-KEL" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLEHAV" b2="69 KV" b3="BEL-TAS" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BELLEHAV" b2="12 KV" b3="D-SMES" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELLEHAV" b2="12 KV" b3="LOAD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BELLEHAV" b2="69 KV" b3="SMES CAP" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLEHAV" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELLAM" b2="69 KV" b3="74" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELLAM" b2="69 KV" b3="75" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TASLEY" b2="69 KV" b3="7470" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TASLEY" b2="69 KV" b3="7480" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1750</SeqNum>
    <Name>L69.KingsCreek-Westover-Kingston-Crisfield.6725</Name>
    <LastEdit Timestamp="2026-02-03T15:10:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISFIE" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISFIE" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISFIE" b2="69 KV" b3="7130" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CRISFIE" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CRISFIE" b2="69 KV" b3="CAP2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRISFIE" b2="69 KV" b3="CRI-KST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CRISFIE" b2="4 KV" b3="G1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CRISFIE" b2="4 KV" b3="G2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CRISFIE" b2="4 KV" b3="G3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CRISFIE" b2="4 KV" b3="G4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRISFIE" b2="12 KV" b3="LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRISFIE" b2="12 KV" b3="LOAD12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRISFIE" b2="25 KV" b3="LOAD25" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRISFIE" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRISFIE" b2="12 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRISFIE" b2="69 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="69 KV" b3="62CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="69 KV" b3="63CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGSCRK" b2="69 KV" b3="KIN-WOR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSTON" b2="69 KV" b3="KNGSTN" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGSTON" b2="69 KV" b3="KST-WOR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOVERDPL" b2="69 KV" b3="WSTOVR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1760</SeqNum>
    <Name>L69.Beaglin-NorthSalisbury.6726</Name>
    <LastEdit Timestamp="2024-12-30T14:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAGLIN" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAGLIN" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAGLIN" b2="69 KV" b3="BEA-NSA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSALISBU" b2="69 KV" b3="61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1770</SeqNum>
    <Name>L69.MountHermon-PineyGrove.6728</Name>
    <LastEdit Timestamp="2026-02-03T09:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MTHERMON" b2="69 KV" b3="7570" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTHERMON" b2="69 KV" b3="MTH-PIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="69 KV" b3="7910" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="69 KV" b3="7960" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="69 KV" b3="7980" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PINEYGRO" b2="69 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1780</SeqNum>
    <Name>L69.Kenney-MtOlive-PineyGrove.6729</Name>
    <LastEdit Timestamp="2025-12-18T16:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNEY" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNEY" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENNEY" b2="69 KV" b3="KEN-MTO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTOLIVE" b2="69 KV" b3="MT-OLV" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTOLIVE" b2="69 KV" b3="MTO-PIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="69 KV" b3="7910" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="69 KV" b3="7920" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1790</SeqNum>
    <Name>L69.DupontSeaford-Laurel.6736</Name>
    <LastEdit Timestamp="2026-02-03T09:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPSEAFD" b2="69 KV" b3="70" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUPSEAFD" b2="69 KV" b3="DUP-LAU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAURELDP" b2="69 KV" b3="62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1800</SeqNum>
    <Name>L69.Bridgeville-Taylor-NorthSeaford.6737</Name>
    <LastEdit Timestamp="2025-09-11T09:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRIDGEVI" b2="69 KV" b3="BRD-TAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEVI" b2="69 KV" b3="CB62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="69 KV" b3="7330" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="69 KV" b3="7340" />
      <ContingencyEquipment Action="L" Type="LN" b1="NSEAFORD" b2="69 KV" b3="NSE-TAT" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="TAYLOR" b2="69 KV" b3="TAYLOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1810</SeqNum>
    <Name>L69.Bridgeville-Kratz-SouthHarrington.6738</Name>
    <LastEdit Timestamp="2025-09-11T09:58:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRIDGEVI" b2="69 KV" b3="BRI-KRAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEVI" b2="69 KV" b3="CB60" />
      <ContingencyEquipment Action="L" Type="LN" b1="KRATZ" b2="69 KV" b3="KRA-SHAR" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="KRATZ" b2="69 KV" b3="KRATZ" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="KRATZ" b2="69 KV" b3="KRATZ" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="KRATZ" b2="69 KV" b3="KRATZ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="69 KV" b3="65" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="69 KV" b3="7270" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="69 KV" b3="7280" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SHARRING" b2="69 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1820</SeqNum>
    <Name>L69.Harrington-SouthHarrington.6739</Name>
    <LastEdit Timestamp="2026-05-13T14:11:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRTN" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRTN" b2="69 KV" b3="7210" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRTN" b2="69 KV" b3="HAR-SHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="69 KV" b3="7260" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="69 KV" b3="7280" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1830</SeqNum>
    <Name>L69.Nelson-Edgewood-NorthSalisbury.6743</Name>
    <LastEdit Timestamp="2026-02-11T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEWDPL" b2="69 KV" b3="EDG-NEL" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEWDPL" b2="69 KV" b3="EDG-NSA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDGEWDPL" b2="69 KV" b3="EDGEWD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEWDPL" b2="69 KV" b3="KUMQUASP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="69 KV" b3="74" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON" b2="69 KV" b3="76" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSALISBU" b2="69 KV" b3="62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1840</SeqNum>
    <Name>L69.Kellam-RedBank-Eastville-Cheriton.6750</Name>
    <LastEdit Timestamp="2024-12-09T12:53:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHERITON" b2="69 KV" b3="3071" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHERITON" b2="69 KV" b3="3072" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHERITON" b2="69 KV" b3="CHE-EAST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHERITON" b2="4 KV" b3="G1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHERITON" b2="4 KV" b3="G2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHERITON" b2="4 KV" b3="G3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHERITON" b2="4 KV" b3="G4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHERITON" b2="4 KV" b3="G5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHERITON" b2="4 KV" b3="G6" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHERITON" b2="69 KV" b3="T1_TXF" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHERITON" b2="69 KV" b3="T2_TXF" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHERITON" b2="25 KV" b3="T3" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTVILL" b2="69 KV" b3="EAS-KEN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTVILL" b2="69 KV" b3="EASTVL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELLAM" b2="69 KV" b3="72" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELLAM" b2="69 KV" b3="73" />
      <ContingencyEquipment Action="L" Type="LN" b1="KELLAM" b2="69 KV" b3="KEL-RED" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KENDLGRV" b2="69 KV" b3="CHERRYSP" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENDLGRV" b2="69 KV" b3="KEN-RED" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REDBDPL" b2="69 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1850</SeqNum>
    <Name>Cheriton.CT1-6</Name>
    <LastEdit Timestamp="2025-11-25T17:04:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHERITON" b2="25 KV" b3="3110" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHERITON" b2="4 KV" b3="G1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHERITON" b2="4 KV" b3="G2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHERITON" b2="4 KV" b3="G3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHERITON" b2="4 KV" b3="G4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHERITON" b2="4 KV" b3="G5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHERITON" b2="4 KV" b3="G6" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHERITON" b2="25 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1860</SeqNum>
    <Name>L69.DupontSeaford-PineStreet-NorthSeaford.6752</Name>
    <LastEdit Timestamp="2026-02-03T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPSEAFD" b2="69 KV" b3="72" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUPSEAFD" b2="69 KV" b3="DUP-PIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="69 KV" b3="7330" />
      <ContingencyEquipment Action="L" Type="LN" b1="NSEAFORD" b2="69 KV" b3="NSE-PIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PINE ST" b2="69 KV" b3="SEACTY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1870</SeqNum>
    <Name>L69.Harrington-Wells-Vaughn-Kent.6784</Name>
    <LastEdit Timestamp="2026-02-03T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRTN" b2="69 KV" b3="7230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRTN" b2="69 KV" b3="7240" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRTN" b2="69 KV" b3="HAR-WEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="7830" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="7840" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENT" b2="69 KV" b3="KEN-VAU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="VAUGHN" b2="69 KV" b3="CENTRALF" />
      <ContingencyEquipment Action="L" Type="LN" b1="VAUGHN" b2="69 KV" b3="VAU-WEL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VAUGHN" b2="69 KV" b3="VAUGHN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WELLS" b2="69 KV" b3="WELLSLD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1880</SeqNum>
    <Name>L138.OakHall-Pocomoke.13787</Name>
    <LastEdit Timestamp="2026-02-03T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="181" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="183" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKHALL" b2="138 KV" b3="OAK-POC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCOMOKE" b2="138 KV" b3="130 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1890</SeqNum>
    <Name>L69.OakHall-Perdue-Tasley.6778</Name>
    <LastEdit Timestamp="2026-02-03T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="69 KV" b3="7260" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="69 KV" b3="7290" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PERDUE" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKHALL" b2="69 KV" b3="OAK-PER" />
      <ContingencyEquipment Action="L" Type="LN" b1="PERDUE" b2="69 KV" b3="PER-TAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TASLEY" b2="69 KV" b3="7450" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TASLEY" b2="69 KV" b3="7460" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1900</SeqNum>
    <Name>L69.OakHall-Hallwood-GreenBush-Tasley.6790</Name>
    <LastEdit Timestamp="2025-10-24T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENBUS" b2="69 KV" b3="8RP" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENBUS" b2="69 KV" b3="GRN-HAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENBUS" b2="69 KV" b3="GRNBSH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HALLWOOD" b2="69 KV" b3="HALLWD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="69 KV" b3="7210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="69 KV" b3="7220" />
      <ContingencyEquipment Action="L" Type="LN" b1="HALLWOOD" b2="69 KV" b3="HAL-OAK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TASLEY" b2="69 KV" b3="7400" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TASLEY" b2="69 KV" b3="7440" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENBUS" b2="69 KV" b3="GRN-TAS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1910</SeqNum>
    <Name>230/138.PineyGrove.AT20</Name>
    <LastEdit Timestamp="2024-12-17T15:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="138 KV" b3="8860" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="138 KV" b3="8870" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="230 KV" b3="9530" />
      <ContingencyEquipment Action="X" Type="XF" b1="PINEYGRO" b2="230 KV" b3="AT20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1920</SeqNum>
    <Name>L230.IndianRiver-PineyGrove.23002</Name>
    <LastEdit Timestamp="2024-12-17T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="230 KV" b3="234" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="230 KV" b3="235" />
      <ContingencyEquipment Action="L" Type="LN" b1="INDIANRI" b2="230 KV" b3="IND-PIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="230 KV" b3="9530" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1930</SeqNum>
    <Name>138/69.Church.AT1</Name>
    <LastEdit Timestamp="2026-02-02T12:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="7260" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="138 KV" b3="8430" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHURCH" b2="138 KV" b3="AT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1940</SeqNum>
    <Name>230/138.Steele.AT20</Name>
    <LastEdit Timestamp="2026-02-03T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="230 KV" b3="250" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="8250" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="8290" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="230 KV" b3="9210" />
      <ContingencyEquipment Action="X" Type="XF" b1="STEELE" b2="230 KV" b3="AT20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1950</SeqNum>
    <Name>230/138.Steele.AT21</Name>
    <LastEdit Timestamp="2026-02-03T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="230 KV" b3="251" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="230 KV" b3="252" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="8270" />
      <ContingencyEquipment Action="X" Type="XF" b1="STEELE" b2="230 KV" b3="AT21" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1960</SeqNum>
    <Name>Steele.138.Cap.1&amp;2</Name>
    <LastEdit Timestamp="2026-02-11T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="8270" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="8280" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="STEELE" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="STEELE" b2="138 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1980</SeqNum>
    <Name>138/69.Cromby.T3</Name>
    <LastEdit Timestamp="2026-02-02T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="69 KV" b3="250 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="138 KV" b3="270 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROMBY" b2="138 KV" b3="CROM3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>1990</SeqNum>
    <Name>138/69.Cromby.T4</Name>
    <LastEdit Timestamp="2026-02-02T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="69 KV" b3="350 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="138 KV" b3="370 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROMBY" b2="138 KV" b3="CROM4TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2020</SeqNum>
    <Name>500/138.Wescosville.T3</Name>
    <LastEdit Timestamp="2024-12-16T16:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WESCOSVI" b2="500 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="138 KV" b3="TRAN3138" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="500 KV" b3="TRAN3_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="500 KV" b3="TRAN3_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2040</SeqNum>
    <Name>500/230.EastWindsor.T1</Name>
    <LastEdit Timestamp="2025-06-18T12:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="500 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="500 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="230 KV" b3="B40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="230 KV" b3="B46" />
      <ContingencyEquipment Action="X" Type="XF" b1="EWINDSOR" b2="500 KV" b3="T-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2050</SeqNum>
    <Name>500/230.EastWindsor.T2</Name>
    <LastEdit Timestamp="2026-02-03T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="230 KV" b3="2F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="500 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="500 KV" b3="B3" />
      <ContingencyEquipment Action="X" Type="XF" b1="EWINDSOR" b2="500 KV" b3="BK 2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="230 KV" b3="G2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2060</SeqNum>
    <Name>500/230.Hunterstown.T1</Name>
    <LastEdit Timestamp="2025-08-11T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HUNTERST" b2="500 KV" b3="1 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="500 KV" b3="B192" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="230 KV" b3="B320" />
      <ContingencyEquipment Action="S" Type="SD" b1="HUNTERST" b2="230 KV" b3="REACT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2070</SeqNum>
    <Name>500/230.Brighton.T1</Name>
    <LastEdit Timestamp="2025-08-25T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="230 KV" b3="1DB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="230 KV" b3="3DB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="500 KV" b3="6BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="500 KV" b3="6CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRIGHTON" b2="500 KV" b3="NO.1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2100</SeqNum>
    <Name>BrandonShores.U1</Name>
    <LastEdit Timestamp="2025-02-25T19:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BRANDONS" b2="230 KV" b3="1GEN XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="23432391" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="2391CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRANDONS" b2="24 KV" b3="GEN 01" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2110</SeqNum>
    <Name>BrandonShores.U2</Name>
    <LastEdit Timestamp="2025-02-25T19:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="23422392" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="2392CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRANDONS" b2="230 KV" b3="2GEN XF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRANDONS" b2="24 KV" b3="GEN 02" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2120</SeqNum>
    <Name>BrunnerIsland.U3</Name>
    <LastEdit Timestamp="2026-02-03T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNNERI" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="GEN_3-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="GEN_3-W" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRUNNERI" b2="24 KV" b3="UNIT03" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2130</SeqNum>
    <Name>CalvertCliffs.U1</Name>
    <LastEdit Timestamp="2025-04-23T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CALVERTC" b2="500 KV" b3="1GEN XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="23" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CALVERTC" b2="25 KV" b3="GEN 01" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2140</SeqNum>
    <Name>CalvertCliffs.U2</Name>
    <LastEdit Timestamp="2025-04-23T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CALVERTC" b2="500 KV" b3="2GEN XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="63" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CALVERTC" b2="22 KV" b3="GEN 02" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2160</SeqNum>
    <Name>ChalkPoint.U3</Name>
    <LastEdit Timestamp="2026-02-03T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="6BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="6CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHALKPT" b2="24 KV" b3="CHLKG3" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHALKPT" b2="230 KV" b3="STAE-U3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2170</SeqNum>
    <Name>ChalkPoint.U4</Name>
    <LastEdit Timestamp="2026-02-03T10:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="7BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="7CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHALKPT" b2="24 KV" b3="CHLKG4" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHALKPT" b2="230 KV" b3="STAE-U4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2180</SeqNum>
    <Name>Conemaugh.U1</Name>
    <LastEdit Timestamp="2026-02-03T10:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONEMAUG" b2="500 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONEMAUG" b2="500 KV" b3="B7" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONEMAUG" b2="500 KV" b3="BK 1 50" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONEMAUG" b2="22 KV" b3="UNIT 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2190</SeqNum>
    <Name>Conemaugh.U2</Name>
    <LastEdit Timestamp="2026-02-03T10:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONEMAUG" b2="500 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONEMAUG" b2="500 KV" b3="B2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONEMAUG" b2="500 KV" b3="BK 2 50" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONEMAUG" b2="22 KV" b3="UNIT02" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2200</SeqNum>
    <Name>Eddystone.U3</Name>
    <LastEdit Timestamp="2026-02-05T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="230 KV" b3="35 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDDYSTON" b2="230 KV" b3="EDDY 3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDDYSTON" b2="20 KV" b3="UNIT03" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2210</SeqNum>
    <Name>Eddystone.U4</Name>
    <LastEdit Timestamp="2026-02-05T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="230 KV" b3="45 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDDYSTON" b2="230 KV" b3="EDDY 4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDDYSTON" b2="20 KV" b3="UNIT04" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2270</SeqNum>
    <Name>Keystone.U1</Name>
    <LastEdit Timestamp="2026-02-05T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B5" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEYSTONE" b2="500 KV" b3="BK 1 50" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEYSTONE" b2="20 KV" b3="UNIT 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2280</SeqNum>
    <Name>Keystone.U2</Name>
    <LastEdit Timestamp="2026-02-05T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B2" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEYSTONE" b2="500 KV" b3="BK 2 50" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEYSTONE" b2="20 KV" b3="UNIT 2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2290</SeqNum>
    <Name>Limerick.U1</Name>
    <LastEdit Timestamp="2025-04-02T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="230 KV" b3="535 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="230 KV" b3="635 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LIMERICK" b2="230 KV" b3="LIM1UNT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LIMERICK" b2="20 KV" b3="UNIT01" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2300</SeqNum>
    <Name>Limerick.U2</Name>
    <LastEdit Timestamp="2025-08-19T10:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="500 KV" b3="235 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="500 KV" b3="335 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LIMERICK" b2="500 KV" b3="LIM2UNT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LIMERICK" b2="20 KV" b3="UNIT02" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2310</SeqNum>
    <Name>MartinsCreek.U3</Name>
    <LastEdit Timestamp="2026-02-05T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MARTINSC" b2="230 KV" b3="G3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="GEN3QUA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="GEN_3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MARTINSC" b2="24 KV" b3="UNIT03" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2320</SeqNum>
    <Name>MartinsCreek.U4</Name>
    <LastEdit Timestamp="2024-08-16T13:50:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MARTINSC" b2="230 KV" b3="G4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="GEN4KLEC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="GEN_4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MARTINSC" b2="24 KV" b3="UNIT04" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2330</SeqNum>
    <Name>Montour.U1</Name>
    <LastEdit Timestamp="2024-05-15T08:03:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MONTOUR" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="24 KV" b3="GEN1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="GEN1SUTI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="GEN_1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MONTOUR" b2="24 KV" b3="UNIT01" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2340</SeqNum>
    <Name>Montour.U2</Name>
    <LastEdit Timestamp="2024-05-15T08:04:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MONTOUR" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="24 KV" b3="GEN2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="GEN2SUSQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="GEN_2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MONTOUR" b2="24 KV" b3="UNIT02" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2380</SeqNum>
    <Name>(NUKE)PeachBottom.U2</Name>
    <LastEdit Timestamp="2025-02-25T19:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="215 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="225 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="230 KV" b3="DUMNK2-1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="13 KV" b3="DUMNK2-3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="230 KV" b3="DUMNK3-1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="13 KV" b3="DUMNK3-3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUK10" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUK11" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="13 KV" b3="DUMNUKE1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="230 KV" b3="DUMNUKE1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="230 KV" b3="DUMNUKE2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="230 KV" b3="DUMNUKE3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE6" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE7" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE8" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE9" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEACHBOT" b2="500 KV" b3="P.B.2TR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PEACHBOT" b2="22 KV" b3="UNIT02" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHTAP" b2="230 KV" b3="DUMNUKE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2390</SeqNum>
    <Name>PeachBottom.U2</Name>
    <LastEdit Timestamp="2025-04-02T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="215 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="225 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEACHBOT" b2="500 KV" b3="P.B.2TR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PEACHBOT" b2="22 KV" b3="UNIT02" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2400</SeqNum>
    <Name>(NUKE)PeachBottom.U3</Name>
    <LastEdit Timestamp="2025-02-25T19:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="15 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="65 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="230 KV" b3="DUMNK2-1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="13 KV" b3="DUMNK2-3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="230 KV" b3="DUMNK3-1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="13 KV" b3="DUMNK3-3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUK10" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUK11" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="13 KV" b3="DUMNUKE1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="230 KV" b3="DUMNUKE1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="230 KV" b3="DUMNUKE2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="230 KV" b3="DUMNUKE3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE6" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE7" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE8" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHBOT" b2="500 KV" b3="DUMNUKE9" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEACHBOT" b2="500 KV" b3="P.B.3TR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PEACHBOT" b2="22 KV" b3="UNIT03" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PEACHTAP" b2="230 KV" b3="DUMNUKE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2410</SeqNum>
    <Name>PeachBottom.U3</Name>
    <LastEdit Timestamp="2025-04-02T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="15 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="65 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEACHBOT" b2="500 KV" b3="P.B.3TR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PEACHBOT" b2="22 KV" b3="UNIT03" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2420</SeqNum>
    <Name>Salem.U1</Name>
    <LastEdit Timestamp="2026-02-10T11:26:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SALEM" b2="25 KV" b3="AUX1LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="SALEM" b2="500 KV" b3="NO 1GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SALEM" b2="25 KV" b3="SALEM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2430</SeqNum>
    <Name>Salem.U2</Name>
    <LastEdit Timestamp="2026-02-10T11:28:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SALEM" b2="25 KV" b3="AUX2LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="SALEM" b2="500 KV" b3="NO 2GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SALEM" b2="25 KV" b3="SALEM2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2440</SeqNum>
    <Name>Susquehanna.U1</Name>
    <LastEdit Timestamp="2026-04-20T12:44:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SUSQUEHA" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="SYNCHRO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUSQUEHA" b2="24 KV" b3="T11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SUSQUEHA" b2="24 KV" b3="UNIT01" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2460</SeqNum>
    <Name>Susquehanna.U2</Name>
    <LastEdit Timestamp="2026-02-11T12:08:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SUSQUEHA" b2="500 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="500 KV" b3="GEN_2-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="500 KV" b3="GEN_2-S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUSQUEHA" b2="69 KV" b3="LD3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUSQUEHA" b2="24 KV" b3="T12" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUSQUEHA" b2="500 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="500 KV" b3="T3-T4_CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SUSQUEHA" b2="24 KV" b3="UNIT02" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2570</SeqNum>
    <Name>L230.MartinsCreek-Portland.1008</Name>
    <LastEdit Timestamp="2025-04-28T23:29:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="LMBEPORT" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARTINSC" b2="230 KV" b3="MAR-POR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="PORT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTLAND" b2="230 KV" b3="B100812" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2580</SeqNum>
    <Name>L230.Portland-Greystone.S1007</Name>
    <LastEdit Timestamp="2025-08-29T13:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREYSTON" b2="230 KV" b3="B44" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREYSTON" b2="230 KV" b3="BK 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTLAND" b2="230 KV" b3="B112" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREYSTON" b2="230 KV" b3="GRE-POR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2590</SeqNum>
    <Name>Bergen.CC1</Name>
    <LastEdit Timestamp="2025-10-10T12:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="138 KV" b3="1112X_HI" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="13 KV" b3="1112X_L1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="13 KV" b3="1112X_L2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="138 KV" b3="1314X_HI" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="13 KV" b3="1314X_L1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="13 KV" b3="1314X_L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="138 KV" b3="3-4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BERGEN" b2="13 KV" b3="CC11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="13 KV" b3="CC11CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BERGEN" b2="13 KV" b3="CC12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="13 KV" b3="CC12CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BERGEN" b2="13 KV" b3="CC13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="13 KV" b3="CC13CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BERGEN" b2="13 KV" b3="CC14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="13 KV" b3="CC14CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="138 KV" b3="NO 1GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="138 KV" b3="SECT 2-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BERGEN" b2="18 KV" b3="UNIT 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2600</SeqNum>
    <Name>Bergen.2CC</Name>
    <LastEdit Timestamp="2026-02-11T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="BERGEN" b2="18 KV" b3="2001 STM" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BERGEN" b2="18 KV" b3="2101 CT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="21CT CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="230 KV" b3="21CT GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BERGEN" b2="18 KV" b3="2202 CT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="22CT CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="230 KV" b3="22CT GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="2STM CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="230 KV" b3="2STM GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2620</SeqNum>
    <Name>BrunnerIsland.U1</Name>
    <LastEdit Timestamp="2026-02-06T09:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNNERI" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="GEN_1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRUNNERI" b2="18 KV" b3="UNIT01" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2630</SeqNum>
    <Name>BrunnerIsland.U2</Name>
    <LastEdit Timestamp="2026-02-06T09:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNNERI" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="GEN_2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRUNNERI" b2="18 KV" b3="UNIT02" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2640</SeqNum>
    <Name>Burlington.CT121 + CT122 + CT123 + CT124</Name>
    <LastEdit Timestamp="2026-02-06T11:46:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURLINGT" b2="230 KV" b3="TR12" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURLINGT" b2="138 KV" b3="TR121" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURLINGT" b2="138 KV" b3="TR122" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURLINGT" b2="138 KV" b3="TR123" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURLINGT" b2="138 KV" b3="TR124" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BURLINGT" b2="13 KV" b3="UNIT121" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BURLINGT" b2="13 KV" b3="UNIT122" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BURLINGT" b2="13 KV" b3="UNIT123" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BURLINGT" b2="13 KV" b3="UNIT124" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2780</SeqNum>
    <Name>Edgemoor.U4</Name>
    <LastEdit Timestamp="2026-02-06T09:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="3-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="3-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="19 KV" b3="UNIT04" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2790</SeqNum>
    <Name>Edgemoor.U5</Name>
    <LastEdit Timestamp="2026-02-06T09:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="230 KV" b3="234" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="230 KV" b3="235" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="230 KV" b3="T5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="23 KV" b3="UNIT05" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2860</SeqNum>
    <Name>IndianRiver.CT10</Name>
    <LastEdit Timestamp="2026-02-06T09:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="69 KV" b3="7060" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDIANRI" b2="69 KV" b3="TG10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="INDIANRI" b2="13 KV" b3="UNIT10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2880</SeqNum>
    <Name>Vienna.U8</Name>
    <LastEdit Timestamp="2026-02-10T10:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="138 KV" b3="8140" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="138 KV" b3="8190" />
      <ContingencyEquipment Action="X" Type="XF" b1="VIENNA" b2="138 KV" b3="T8" />
      <ContingencyEquipment Action="U" Type="GEN" b1="VIENNA" b2="18 KV" b3="UNIT08" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2890</SeqNum>
    <Name>Independence.6CC (NYISO)</Name>
    <LastEdit Timestamp="2026-02-11T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="INDEPEND" b2="18 KV" b3="GT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="INDEPEND" b2="18 KV" b3="GT4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDEPEND" b2="345 KV" b3="R270" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDEPEND" b2="345 KV" b3="R915" />
      <ContingencyEquipment Action="U" Type="GEN" b1="INDEPEND" b2="18 KV" b3="ST6" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDEPEND" b2="345 KV" b3="TB3" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDEPEND" b2="345 KV" b3="TB4" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDEPEND" b2="345 KV" b3="TB6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>2900</SeqNum>
    <Name>JAFitzpatrick.U1</Name>
    <LastEdit Timestamp="2025-10-07T10:30:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JAFITZP" b2="345 KV" b3="10031" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JAFITZP" b2="24 KV" b3="FTZPTRK" />
      <ContingencyEquipment Action="X" Type="XF" b1="JAFITZP" b2="345 KV" b3="T1A_T1B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3040</SeqNum>
    <Name>Shawville.U3</Name>
    <LastEdit Timestamp="2026-02-10T10:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWVILL" b2="230 KV" b3="BNK #3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWVILL" b2="230 KV" b3="NO3TX230" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SHAWVILL" b2="22 KV" b3="UNIT 3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3050</SeqNum>
    <Name>Shawville.U4</Name>
    <LastEdit Timestamp="2026-02-10T10:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWVILL" b2="230 KV" b3="BNK #4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWVILL" b2="230 KV" b3="NO4TX230" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SHAWVILL" b2="22 KV" b3="UNIT 4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3070</SeqNum>
    <Name>Wagner.U4</Name>
    <LastEdit Timestamp="2026-02-11T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="130001OC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="4GENOCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDONS" b2="230 KV" b3="BRA-WAG4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WAGNER" b2="13 KV" b3="GEN 04" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAGNER" b2="230 KV" b3="U4 XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3100</SeqNum>
    <Name>Wagner.U3</Name>
    <LastEdit Timestamp="2026-02-10T11:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="3GENSYN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WAGNER" b2="13 KV" b3="GEN 03" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAGNER" b2="115 KV" b3="U3 XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3130</SeqNum>
    <Name>L500.Branchburg-Elroy.5017 + Elroy.T1&amp;T2</Name>
    <LastEdit Timestamp="2026-02-06T09:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="500 KV" b3="SECT 5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="500 KV" b3="SECT 6-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROY" b2="500 KV" b3="175 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROY" b2="500 KV" b3="475 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANCHBU" b2="500 KV" b3="BRA-ELR" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELROYPL" b2="500 KV" b3="1 TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELROYPL" b2="138 KV" b3="2 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROYPL" b2="500 KV" b3="TRAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROYPL" b2="138 KV" b3="TRAN1DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROYPL" b2="69 KV" b3="TRAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROYPL" b2="138 KV" b3="TRAN2DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3150</SeqNum>
    <Name>L500.NewFreedom-Salem.5024</Name>
    <LastEdit Timestamp="2024-06-19T15:14:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="NEWFREED" b2="500 KV" b3="NEW-SAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT7-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3160</SeqNum>
    <Name>L500.Hosensack-Elroy.5028 + 500/138.Elroy.T3</Name>
    <LastEdit Timestamp="2025-05-09T11:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROY" b2="500 KV" b3="145 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROY" b2="500 KV" b3="475 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELROY" b2="500 KV" b3="ELR-ELR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELROY" b2="500 KV" b3="ELR-HOS" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELROYPL" b2="500 KV" b3="3 TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELROYPL" b2="138 KV" b3="4 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROYPL" b2="500 KV" b3="TRAN3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="500 KV" b3="ELROLAUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="500 KV" b3="ELROY CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3170</SeqNum>
    <Name>L500.Limerick-PeachBottom.5010</Name>
    <LastEdit Timestamp="2025-01-17T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="500 KV" b3="225 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="500 KV" b3="325 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIMERICK" b2="500 KV" b3="LIM-PEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="55 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="65 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3180</SeqNum>
    <Name>L500.PeachBottom-TMI.5007</Name>
    <LastEdit Timestamp="2026-05-07T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="25 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="35 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="PEACHBOT" b2="500 KV" b3="PEA-TMI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="500 KV" b3="070802" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="500 KV" b3="500702" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3200</SeqNum>
    <Name>L500.Alburtis-Branchburg.5016</Name>
    <LastEdit Timestamp="2025-02-25T19:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBURTIS" b2="500 KV" b3="ALB-BRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTIS" b2="500 KV" b3="BRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTIS" b2="500 KV" b3="BREI2BRN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="500 KV" b3="16-17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="500 KV" b3="8-16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3210</SeqNum>
    <Name>L500.Alburtis-Hosensack.5027</Name>
    <LastEdit Timestamp="2025-01-15T18:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBURTIS" b2="500 KV" b3="ALB-HOS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTIS" b2="500 KV" b3="HOSE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTIS" b2="500 KV" b3="JUNIHOSE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="500 KV" b3="ALBU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="500 KV" b3="ELROY CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3220</SeqNum>
    <Name>L500.Alburtis-Juniata.5009</Name>
    <LastEdit Timestamp="2025-01-15T18:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBURTIS" b2="500 KV" b3="ALB-JUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTIS" b2="500 KV" b3="JUNI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTIS" b2="500 KV" b3="JUNIHOSE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="500 KV" b3="ALBU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="500 KV" b3="KEYSALBU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3230</SeqNum>
    <Name>L500.Juniata-Keystone.5004</Name>
    <LastEdit Timestamp="2026-03-23T20:46:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIATA" b2="500 KV" b3="JUN-KEY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="500 KV" b3="KEYS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="500 KV" b3="KEYSALBU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3240</SeqNum>
    <Name>L500.Juniata-TMI.5008</Name>
    <LastEdit Timestamp="2026-02-06T09:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="500 KV" b3="CONETMIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIATA" b2="500 KV" b3="JUN-TMI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="500 KV" b3="TMIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="500 KV" b3="070802" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="500 KV" b3="500802" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3300</SeqNum>
    <Name>L500.Conastone-PeachBottom.5012</Name>
    <LastEdit Timestamp="2025-08-25T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="500 KV" b3="500 B CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="500 KV" b3="500 C CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="235 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="245 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONASTON" b2="500 KV" b3="CNS-PEA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3310</SeqNum>
    <Name>L500.Conemaugh-Juniata.5005</Name>
    <LastEdit Timestamp="2024-12-18T08:06:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONEMAUG" b2="500 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONEMAUG" b2="500 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONEMAUG" b2="500 KV" b3="CNM-JUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="500 KV" b3="CONE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="500 KV" b3="CONETMIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3320</SeqNum>
    <Name>L500.Conemaugh-Keystone.5003</Name>
    <LastEdit Timestamp="2026-04-01T15:02:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONEMAUG" b2="500 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONEMAUG" b2="500 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONEMAUG" b2="500 KV" b3="CNM-KEY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3330</SeqNum>
    <Name>L500.Keystone-SouthBend.5001(513)</Name>
    <LastEdit Timestamp="2025-08-25T10:27:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEYSTONE" b2="500 KV" b3="KEY-SBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBEND" b2="500 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBEND" b2="500 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3340</SeqNum>
    <Name>L500.Cabot-Keystone.5002</Name>
    <LastEdit Timestamp="2026-02-06T09:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="500 KV" b3="CB 05" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="500 KV" b3="CB 06" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B16" />
      <ContingencyEquipment Action="L" Type="LN" b1="CABOT" b2="500 KV" b3="CAB-KEY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3350</SeqNum>
    <Name>L500.Keeney-RockSprings.5025</Name>
    <LastEdit Timestamp="2025-12-29T10:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="500 KV" b3="501" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="500 KV" b3="505" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEENEY" b2="500 KV" b3="KEE-ROC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKSPRI" b2="500 KV" b3="52-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKSPRI" b2="500 KV" b3="52-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3380</SeqNum>
    <Name>L500.Bedington-BlackOak</Name>
    <LastEdit Timestamp="2025-11-18T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="BDL3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="BDL4 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEDINGTO" b2="500 KV" b3="BED-BLA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKOAK" b2="500 KV" b3="BOL2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKOAK" b2="500 KV" b3="BOL3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3390</SeqNum>
    <Name>L500.Bedington-Doubs.520</Name>
    <LastEdit Timestamp="2025-11-21T15:05:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="BDL1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="BDL2 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEDINGTO" b2="500 KV" b3="BED-DOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="CB 51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="CB 54" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3400</SeqNum>
    <Name>L500.MtStorm-Pruntytown.554</Name>
    <LastEdit Timestamp="2026-03-30T09:18:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="554TB3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="554TB4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="500 KV" b3="B124" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="500 KV" b3="B125" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTSTORM4" b2="500 KV" b3="MTS-PRU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3410</SeqNum>
    <Name>500/230.Branchburg.500-1</Name>
    <LastEdit Timestamp="2026-02-05T10:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BRANCHBU" b2="500 KV" b3="500-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="500 KV" b3="500-1HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT9-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT9-13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3420</SeqNum>
    <Name>500/230.Branchburg.500-2</Name>
    <LastEdit Timestamp="2025-05-30T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BRANCHBU" b2="500 KV" b3="500-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="500 KV" b3="500-2HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT 2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT 7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3430</SeqNum>
    <Name>500/230.NewFreedom.500-1</Name>
    <LastEdit Timestamp="2026-02-06T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="230 1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="230 3-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWFREED" b2="500 KV" b3="500 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3440</SeqNum>
    <Name>500/230.NewFreedom.500-2</Name>
    <LastEdit Timestamp="2026-02-06T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="230 1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="230 5-6" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWFREED" b2="500 KV" b3="500-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3450</SeqNum>
    <Name>500/230.NewFreedom.500-3</Name>
    <LastEdit Timestamp="2026-02-06T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="230 1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="230 7-8" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWFREED" b2="500 KV" b3="500-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3460</SeqNum>
    <Name>500/230.NewFreedom.500-4</Name>
    <LastEdit Timestamp="2026-02-06T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="1-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="11_12" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWFREED" b2="500 KV" b3="500-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3470</SeqNum>
    <Name>500/230.Juniata.T2</Name>
    <LastEdit Timestamp="2025-04-09T13:35:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="JUNIATA" b2="500 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="500 KV" b3="TRAN2FBA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="230 KV" b3="TRAN2_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="230 KV" b3="TRAN2_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3500</SeqNum>
    <Name>500/230.Conastone.500-2</Name>
    <LastEdit Timestamp="2025-08-25T15:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="2302 GCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="2322 GCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="2323 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="2324_GCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="500 KV" b3="500 K CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="500 KV" b3="500 L CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONASTON" b2="500 KV" b3="500-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3520</SeqNum>
    <Name>500/230.Conastone.500-4</Name>
    <LastEdit Timestamp="2025-08-25T15:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="2310CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="2323 4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="3 SS TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="500 KV" b3="500 A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="500 KV" b3="500 B CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="500-1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONASTON" b2="500 KV" b3="500-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3530</SeqNum>
    <Name>500/230.TMI.T1</Name>
    <LastEdit Timestamp="2025-11-12T10:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TMI" b2="500 KV" b3="1 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="500 KV" b3="500802" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="500 KV" b3="502602" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TMI" b2="500 KV" b3="A43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="230 KV" b3="B38" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3540</SeqNum>
    <Name>500/230.Keeney.AT50</Name>
    <LastEdit Timestamp="2026-02-05T10:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="236" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="237" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="500 KV" b3="505" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="500 KV" b3="507" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEENEY" b2="500 KV" b3="AT50" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3550</SeqNum>
    <Name>500/230.Keeney.AT51</Name>
    <LastEdit Timestamp="2026-02-05T10:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="233" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="234" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="500 KV" b3="501" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="500 KV" b3="502" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEENEY" b2="500 KV" b3="AT51" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3560</SeqNum>
    <Name>L500.CalvertCliffs-ChalkPoint.5072</Name>
    <LastEdit Timestamp="2025-04-23T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="500 KV" b3="12BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="500 KV" b3="12CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CALVERTC" b2="500 KV" b3="CAL-CHA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3570</SeqNum>
    <Name>L500.CalvertCliffs-WaughChapel.5052</Name>
    <LastEdit Timestamp="2025-05-22T12:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="43" />
      <ContingencyEquipment Action="L" Type="LN" b1="CALVERTC" b2="500 KV" b3="CAL-WAU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="500 KV" b3="3TR_5052" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="500 KV" b3="5052" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3580</SeqNum>
    <Name>L500.Brighton-WaughChapel</Name>
    <LastEdit Timestamp="2025-08-25T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="500 KV" b3="5AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="500 KV" b3="5BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="500 KV" b3="4TR_5053" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="500 KV" b3="5053CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIGHTON" b2="500 KV" b3="BRI-WAU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3590</SeqNum>
    <Name>L500.Brighton-Conastone.5011</Name>
    <LastEdit Timestamp="2025-08-25T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="500 KV" b3="6AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="500 KV" b3="6BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="500 KV" b3="500 H CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="500 KV" b3="500 J CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIGHTON" b2="500 KV" b3="BRI-CNS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3600</SeqNum>
    <Name>L500.Brighton-Doubs.5055</Name>
    <LastEdit Timestamp="2025-08-25T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="500 KV" b3="7AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="500 KV" b3="7BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIGHTON" b2="500 KV" b3="BRI-DOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="CB 51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="CB 55" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3610</SeqNum>
    <Name>L69.WestNyack-Orangeburg-Sparkill (NYISO)</Name>
    <LastEdit Timestamp="2024-10-03T15:18:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ORANGEBU" b2="69 KV" b3="ALUFPLAS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ORANGEBU" b2="69 KV" b3="BK254 LD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ORANGEBU" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ORANGEBU" b2="69 KV" b3="CAP2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ORANGEBU" b2="69 KV" b3="ORA-SPA" />
      <ContingencyEquipment Action="L" Type="LN" b1="ORANGEBU" b2="69 KV" b3="ORA-WNY" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SPARKILL" b2="69 KV" b3="750-50-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WNYACK" b2="69 KV" b3="75-21-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3620</SeqNum>
    <Name>L500.Hunterstown-Conastone.5013</Name>
    <LastEdit Timestamp="2025-08-25T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="500 KV" b3="500 L CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="500 KV" b3="500 M CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONASTON" b2="500 KV" b3="CNS-HUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="500 KV" b3="B325" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="500 KV" b3="B40" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3630</SeqNum>
    <Name>500/13/230.Limerick.T4A&amp;T4B</Name>
    <LastEdit Timestamp="2025-10-15T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="500 KV" b3="115 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LIMERICK" b2="13 KV" b3="20AUX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="500 KV" b3="315 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="LIMERICK" b2="500 KV" b3="4ABLEAD1" />
      <ContingencyEquipment Action="S" Type="SD" b1="LIMERICK" b2="230 KV" b3="4ABLEAD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="230 KV" b3="525 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="230 KV" b3="625 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LIMERICK" b2="500 KV" b3="LIM 4A-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="LIMERICK" b2="230 KV" b3="LIM 4A-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="LIMERICK" b2="13 KV" b3="LIM 4A-T" />
      <ContingencyEquipment Action="X" Type="XF" b1="LIMERICK" b2="500 KV" b3="LIM 4B-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="LIMERICK" b2="230 KV" b3="LIM 4B-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="LIMERICK" b2="13 KV" b3="LIM 4B-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3640</SeqNum>
    <Name>L500.Limerick-Whitpain.5030+500/230.Whitpain.500-1</Name>
    <LastEdit Timestamp="2025-01-15T18:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="500 KV" b3="125 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="500 KV" b3="225 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="230 KV" b3="115 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="500 KV" b3="185 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="500 KV" b3="475 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIMERICK" b2="500 KV" b3="LIM-WHI0" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHITPAIN" b2="500 KV" b3="WHT 1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3650</SeqNum>
    <Name>L500.Limerick-Whitpain.5031+500/230.Whitpain.500-2</Name>
    <LastEdit Timestamp="2025-01-15T18:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="500 KV" b3="135 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="500 KV" b3="235 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="230 KV" b3="225 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="500 KV" b3="285 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="500 KV" b3="575 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIMERICK" b2="500 KV" b3="LIM-WHI1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHITPAIN" b2="500 KV" b3="WHT 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3680</SeqNum>
    <Name>L500.Deans-Smithburg.5020</Name>
    <LastEdit Timestamp="2026-01-27T10:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="500 KV" b3="SECT 2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="500 KV" b3="SECT 7-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHBUR" b2="500 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEANS" b2="500 KV" b3="DEA-SMI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3710</SeqNum>
    <Name>L500.Susquehanna-Wescosville.5043</Name>
    <LastEdit Timestamp="2025-02-10T11:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="500 KV" b3="WESC_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="500 KV" b3="WESC_S" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUSQUEHA" b2="500 KV" b3="SUS-WES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="500 KV" b3="SUSQ_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="500 KV" b3="SUSQ_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3730</SeqNum>
    <Name>L500.Salem-Orchard.5021</Name>
    <LastEdit Timestamp="2026-02-06T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARD" b2="500 KV" b3="GCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARD" b2="500 KV" b3="GCB B" />
      <ContingencyEquipment Action="L" Type="LN" b1="ORCHARD" b2="500 KV" b3="ORC-SAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT1-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT2-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3760</SeqNum>
    <Name>Chateaugay.HVDC.Tie (NYISO)</Name>
    <LastEdit Timestamp="2025-07-28T12:01:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CHATEAUG" b2="765 KV" b3="AC-GEN" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHATEAUG" b2="765 KV" b3="CHA-MAS" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHATEAUG" b2="765 KV" b3="DC-A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHATEAUG" b2="765 KV" b3="DC-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASSENA" b2="765 KV" b3="7102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASSENA" b2="765 KV" b3="7108" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASSENA" b2="765 KV" b3="7122" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MASSENA" b2="765 KV" b3="REACT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3810</SeqNum>
    <Name>RAS.500/230.PeachBottom.T1 + MuddyRun.U5-8</Name>
    <LastEdit Timestamp="2025-05-19T15:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUDDYRN" b2="230 KV" b3="075 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MUDDYRN" b2="230 KV" b3="MR 3TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="MUDDYRN" b2="230 KV" b3="MR 4TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="MUDDYRN" b2="230 KV" b3="MUD-PEA7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT8" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEACHBOT" b2="500 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEACHBOT" b2="230 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEACHBOT" b2="13 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="230 KV" b3="175 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="35 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEACHBOT" b2="13 KV" b3="3SU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="45 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="230 KV" b3="475" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEACHBOT" b2="230 KV" b3="4TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="230 KV" b3="675 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3820</SeqNum>
    <Name>L230.SteelCity-Quarry.2</Name>
    <LastEdit Timestamp="2025-06-05T08:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="QUARRY" b2="230 KV" b3="QUA-STE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="230 KV" b3="STCI2_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="230 KV" b3="STCI2_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELCTY" b2="230 KV" b3="BEP2QUA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELCTY" b2="230 KV" b3="QUAR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3870</SeqNum>
    <Name>L115.Pumphrey-Westport-ClareSt.110526</Name>
    <LastEdit Timestamp="2025-05-13T11:09:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CLAREST" b2="115 KV" b3="110-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLAREST" b2="34.5 KV" b3="110-2LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAREST" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAREST" b2="115 KV" b3="CLA-WES2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="110526" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="526_534" />
      <ContingencyEquipment Action="X" Type="XF" b1="WESTPORT" b2="115 KV" b3="110-10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTPORT" b2="13 KV" b3="110-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="110526CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="526-554" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="526-586" />
      <ContingencyEquipment Action="L" Type="LN" b1="PUMPHREY" b2="115 KV" b3="PUM-WES6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3880</SeqNum>
    <Name>L115.Pumphrey-Westport.110524 + 115/24.110-6</Name>
    <LastEdit Timestamp="2025-11-17T15:28:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="110524" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="524_532" />
      <ContingencyEquipment Action="L" Type="LN" b1="PUMPHREY" b2="115 KV" b3="PUM-WES4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="34 KV" b3="110-6BBB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="34 KV" b3="110-6RBB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="110524-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="524-553" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREE BC" b2="115 KV" b3="GRE-WES3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="T4X" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3900</SeqNum>
    <Name>L230.Brighton-Burtonsville.23013</Name>
    <LastEdit Timestamp="2026-02-06T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="230 KV" b3="3BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="23013B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIGHTON" b2="230 KV" b3="BRI-BUR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3910</SeqNum>
    <Name>L230.Brighton-Burtonsville.23012</Name>
    <LastEdit Timestamp="2026-02-06T09:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="230 KV" b3="1BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIGHTON" b2="230 KV" b3="BRI-BUR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="23012B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3920</SeqNum>
    <Name>L230.Byberry-Woodbourne.220-22+WDBTR6+BYBTR6&amp;18&amp;21</Name>
    <LastEdit Timestamp="2025-09-08T08:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BYBERRY" b2="138 KV" b3="160 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BYBERRY" b2="13 KV" b3="18TRLSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BYBERRY" b2="13 KV" b3="21TRLSCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BYBERRY" b2="230 KV" b3="BYB 6TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="BYBERRY" b2="230 KV" b3="BYB-WOO" />
      <ContingencyEquipment Action="X" Type="XF" b1="BYBERRY" b2="138 KV" b3="BYB18TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="BYBERRY" b2="138 KV" b3="BYB21TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODBOUR" b2="35 KV" b3="665 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODBOUR" b2="230 KV" b3="705 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODBOUR" b2="230 KV" b3="WDB 6TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3960</SeqNum>
    <Name>L115.Center-Erdman.110555</Name>
    <LastEdit Timestamp="2025-04-28T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CENTER" b2="115 KV" b3="110-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTER" b2="115 KV" b3="555556GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTER" b2="115 KV" b3="555589GC" />
      <ContingencyEquipment Action="CL" Type="CB" b1="CENTER" b2="13 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTER" b2="115 KV" b3="CEN-ERD5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTER" b2="13 KV" b3="DUM4LSBK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERDMAN" b2="115 KV" b3="555_605" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3970</SeqNum>
    <Name>L115.Pumphrey-Westport-ClareSt.110525</Name>
    <LastEdit Timestamp="2025-04-26T11:50:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CLAREST" b2="115 KV" b3="110-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAREST" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAREST" b2="115 KV" b3="CLA-WES1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PUMPHREY" b2="115 KV" b3="PUM-WES5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="S525_2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="SW110525" />
      <ContingencyEquipment Action="X" Type="XF" b1="WESTPORT" b2="115 KV" b3="110-9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTPORT" b2="13 KV" b3="110-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="110525" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3980</SeqNum>
    <Name>L115.Center-Erdman.110556</Name>
    <LastEdit Timestamp="2025-04-28T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CENTER" b2="115 KV" b3="110-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTER" b2="115 KV" b3="552556OC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTER" b2="115 KV" b3="555556GC" />
      <ContingencyEquipment Action="CL" Type="CB" b1="CENTER" b2="13 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTER" b2="115 KV" b3="CEN-ERD6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTER" b2="13 KV" b3="DUM1LSBK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERDMAN" b2="115 KV" b3="556_606" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>3990</SeqNum>
    <Name>L115.Westport-Pumphrey.110521</Name>
    <LastEdit Timestamp="2025-05-01T09:50:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="110521" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="521_535" />
      <ContingencyEquipment Action="L" Type="LN" b1="PUMPHREY" b2="115 KV" b3="PUM-WES1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="110521CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="585-521" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4000</SeqNum>
    <Name>L230.ChalkPoint-Ryceville-Morgantown.23071/2</Name>
    <LastEdit Timestamp="2026-02-11T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="2BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="2CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHALKPT" b2="230 KV" b3="CHA-RYC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="11BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="11CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RYCEVILL" b2="230 KV" b3="536" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORGANTO" b2="230 KV" b3="MOR-RYC1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4010</SeqNum>
    <Name>L230.ChalkPoint-Ryceville-Morgantown.23073/4</Name>
    <LastEdit Timestamp="2026-02-11T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="1BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="1CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHALKPT" b2="230 KV" b3="CHA-RYC4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="10BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RYCEVILL" b2="230 KV" b3="540" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORGANTO" b2="230 KV" b3="MOR-RYC3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4020</SeqNum>
    <Name>L230.Chester-WestWharton.H2034</Name>
    <LastEdit Timestamp="2026-03-27T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTJCT" b2="230 KV" b3="B106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTJCT" b2="35 KV" b3="BK 4LCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTJCT" b2="230 KV" b3="BK 4TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTJCT" b2="230 KV" b3="CHE-WWH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="230 KV" b3="B54" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="34 KV" b3="BK2E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="34 KV" b3="BK2F" />
      <ContingencyEquipment Action="X" Type="XF" b1="WWHARTON" b2="230 KV" b3="BK_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="230 KV" b3="EH OC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4030</SeqNum>
    <Name>230/138.Chichester.9A/B</Name>
    <LastEdit Timestamp="2024-12-06T10:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="230 KV" b3="195CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="138 KV" b3="795CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHICHEST" b2="230 KV" b3="9A" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHICHEST" b2="230 KV" b3="9B" />
      <ContingencyEquipment Action="S" Type="SD" b1="CHICHEST" b2="138 KV" b3="SD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4040</SeqNum>
    <Name>L230.Claymont-Linwood.220-84</Name>
    <LastEdit Timestamp="2025-01-06T16:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYMONT" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYMONT" b2="230 KV" b3="233" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="125" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYMONT" b2="230 KV" b3="CLA-LIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4050</SeqNum>
    <Name>L230.Edgemoor-Linwood.220-85</Name>
    <LastEdit Timestamp="2025-09-03T09:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="230 KV" b3="233" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="230 KV" b3="234" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="125" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="205" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEMOOR" b2="230 KV" b3="EDG-LIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4060</SeqNum>
    <Name>L230.Chambers-Churchtown.2313</Name>
    <LastEdit Timestamp="2026-02-06T09:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBERS" b2="230 KV" b3="BUSGCBA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBERS" b2="230 KV" b3="BUSGCBC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="230 KV" b3="BUSGCBA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="230 KV" b3="BUSGCBC" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAMBERS" b2="230 KV" b3="CHA-CHU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4070</SeqNum>
    <Name>L230.Chambers-Pedricktown.2312</Name>
    <LastEdit Timestamp="2026-02-06T09:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBERS" b2="230 KV" b3="BUSGCBA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBERS" b2="230 KV" b3="BUSGCBB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAMBERS" b2="230 KV" b3="CHA-PED" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEDRICKT" b2="230 KV" b3="BUSGCBA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEDRICKT" b2="230 KV" b3="BUSGCBB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4080</SeqNum>
    <Name>L230.CedarGrove-CedarSub-Roseland.Y-2277</Name>
    <LastEdit Timestamp="2026-02-06T09:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="230 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARSUB" b2="230 KV" b3="CED-CEDY" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CEDARSUB" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="3-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="3-13" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARSUB" b2="230 KV" b3="CED-ROSY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4090</SeqNum>
    <Name>L230.Clinton-Elimsport</Name>
    <LastEdit Timestamp="2024-11-14T15:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLINTON" b2="230 KV" b3="CLI-ELI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON" b2="230 KV" b3="ELIM_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON" b2="230 KV" b3="ELIM_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMSPOR" b2="230 KV" b3="CLINTONE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMSPOR" b2="230 KV" b3="CLINTONW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4110</SeqNum>
    <Name>L230.Frackville-Colu+Colu.T1</Name>
    <LastEdit Timestamp="2024-09-24T10:00:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="COLU PL" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="230 KV" b3="MONT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="69 KV" b3="TRAN_1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLU PL" b2="230 KV" b3="COL-FRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="230 KV" b3="COLUNEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="230 KV" b3="TR3_COLU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4120</SeqNum>
    <Name>L230.Columbia-Montour+230/69.Columbia.T2</Name>
    <LastEdit Timestamp="2024-09-23T11:08:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="COLU PL" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLU PL" b2="230 KV" b3="COL-MON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="230 KV" b3="MONT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="69 KV" b3="TRAN_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="BAY7COLU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="COLU_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4140</SeqNum>
    <Name>L230.Chichester-Foulk.220-04</Name>
    <LastEdit Timestamp="2025-07-29T11:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="230 KV" b3="045 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOULK" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOULK" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICHEST" b2="230 KV" b3="CHI-FOU" />
      <ContingencyEquipment Action="X" Type="XF" b1="FOULK" b2="230 KV" b3="FOU 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4160</SeqNum>
    <Name>L230.Lenape-Concord.220-70</Name>
    <LastEdit Timestamp="2026-02-06T11:47:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC PE" b2="35 KV" b3="115 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC PE" b2="230 KV" b3="455 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONC PE" b2="230 KV" b3="CON 1TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONC PE" b2="230 KV" b3="CON-LEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LENAPE" b2="35 KV" b3="225 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LENAPE" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LENAPE" b2="230 KV" b3="LEN2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4170</SeqNum>
    <Name>L230.Middletown-Concord.220-25</Name>
    <LastEdit Timestamp="2025-01-15T18:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC PE" b2="230 KV" b3="255 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONC PE" b2="230 KV" b3="CON-MID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD PE" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD PE" b2="35 KV" b3="555 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD PE" b2="230 KV" b3="875 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDD PE" b2="230 KV" b3="MID 1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDD PE" b2="230 KV" b3="MID 5TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4180</SeqNum>
    <Name>L138.FoxChase-Crescentville.130-24 + Crescent.T7</Name>
    <LastEdit Timestamp="2025-06-05T12:45:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESCENT" b2="138 KV" b3="705 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESCENT" b2="13 KV" b3="7TRLS" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRESCENT" b2="138 KV" b3="CRE-FOX" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRESCENT" b2="138 KV" b3="CRS 7TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOXCHASE" b2="138 KV" b3="245 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4190</SeqNum>
    <Name>L138.Waneeta-Crescentville.130-01</Name>
    <LastEdit Timestamp="2025-06-12T11:16:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESCENT" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESCENT" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESCENT" b2="138 KV" b3="805 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRESCENT" b2="138 KV" b3="CRS 1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRESCENT" b2="138 KV" b3="CRS 3TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="138 KV" b3="15 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRESCENT" b2="138 KV" b3="CRE-WAN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4200</SeqNum>
    <Name>L138.Waneeta-Crescentville.130-03 + Crescent.T4&amp;5</Name>
    <LastEdit Timestamp="2025-05-28T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESCENT" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESCENT" b2="13 KV" b3="5TRLS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESCENT" b2="138 KV" b3="905 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRESCENT" b2="138 KV" b3="CRS 4TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRESCENT" b2="138 KV" b3="CRS 5TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="138 KV" b3="35 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRESCENT" b2="138 KV" b3="CRE-WAN3" />
      <ContingencyEquipment Action="S" Type="SD" b1="WANEETA" b2="138 KV" b3="SD_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4210</SeqNum>
    <Name>L138.Cromby-Perkiomen</Name>
    <LastEdit Timestamp="2025-01-16T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="138 KV" b3="320 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROMBY" b2="138 KV" b3="CRO-PER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERKIOME" b2="138 KV" b3="305" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4220</SeqNum>
    <Name>L230.Limerick-Lock.220-61</Name>
    <LastEdit Timestamp="2026-05-04T15:10:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="230 KV" b3="635 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="230 KV" b3="735 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIMERICK" b2="230 KV" b3="LIM-LOC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCK" b2="230 KV" b3="605" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCK" b2="230 KV" b3="705" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4230</SeqNum>
    <Name>L230.Limerick-Cromby.220-60</Name>
    <LastEdit Timestamp="2026-02-06T09:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="230 KV" b3="605 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROMBY" b2="230 KV" b3="CRO-LIM0" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="230 KV" b3="515 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="230 KV" b3="715 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4240</SeqNum>
    <Name>L230.RemingtonCT-Opal-Warrenton.2155</Name>
    <LastEdit Timestamp="2024-05-13T11:32:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OPAL" b2="230 KV" b3="H172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPAL" b2="230 KV" b3="H272" />
      <ContingencyEquipment Action="L" Type="LN" b1="OPAL" b2="230 KV" b3="OPA-WARR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="21142155" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="215562" />
      <ContingencyEquipment Action="L" Type="LN" b1="OPAL" b2="230 KV" b3="OPA-REMN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRENTN" b2="230 KV" b3="20862155" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRENTN" b2="230 KV" b3="H152CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4250</SeqNum>
    <Name>L230.Camden-CuthbertBlvd.U-2299</Name>
    <LastEdit Timestamp="2026-02-11T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDEN" b2="230 KV" b3="1-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDEN" b2="230 KV" b3="11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUTHBERT" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUTHBERT" b2="230 KV" b3="2-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMDEN" b2="230 KV" b3="CAM-CUTU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CUTHBERT" b2="230 KV" b3="T30LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4260</SeqNum>
    <Name>L230.CuthbertBlvd-Gloucester.C-2308</Name>
    <LastEdit Timestamp="2026-02-06T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUTHBERT" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUTHBERT" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CUTHBERT" b2="230 KV" b3="T10-20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUTHBERT" b2="230 KV" b3="T20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="2-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CUTHBERT" b2="230 KV" b3="CUT-GLOC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4280</SeqNum>
    <Name>L230.Dauphin-Juniata+230/69.Dauphin.T2</Name>
    <LastEdit Timestamp="2025-04-16T11:37:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DAUPHIN" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAUPHIN" b2="230 KV" b3="DAU-JUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAUPHIN" b2="230 KV" b3="JUNICOP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAUPHIN" b2="69 KV" b3="TRAN_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="230 KV" b3="DAUP_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="230 KV" b3="DAUP_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4290</SeqNum>
    <Name>L230.Deans-NewDover-Westfield.W-2249</Name>
    <LastEdit Timestamp="2025-01-14T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DEANS" b2="230 KV" b3="DEA-NEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="230 KV" b3="SECT 1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="230 KV" b3="SECT 5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWDOVER" b2="230 KV" b3="NEW-WES" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWDOVER" b2="230 KV" b3="T20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTFIEL" b2="230 KV" b3="230SC1-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTFIEL" b2="230 KV" b3="T-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4300</SeqNum>
    <Name>L230.Brunswick-Deans.D-2204</Name>
    <LastEdit Timestamp="2024-12-03T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SEC15-16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SEC4-16" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNSWIC" b2="230 KV" b3="BRU-DEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="230 KV" b3="SECT 1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="230 KV" b3="SECT9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4310</SeqNum>
    <Name>L230.Dickerson-QuinceOrchard.23033</Name>
    <LastEdit Timestamp="2026-02-06T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSO" b2="230 KV" b3="3AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSO" b2="230 KV" b3="3BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DICKERSO" b2="230 KV" b3="DIC-QUI3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23033B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4320</SeqNum>
    <Name>L230.DickersonH-QuinceOrchard.23032</Name>
    <LastEdit Timestamp="2026-02-06T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSH" b2="230 KV" b3="45B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSH" b2="230 KV" b3="45C" />
      <ContingencyEquipment Action="L" Type="LN" b1="DICKERSH" b2="230 KV" b3="DIC-QUI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23032B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4340</SeqNum>
    <Name>L230.Dickerson-QuinceOrchard.23035</Name>
    <LastEdit Timestamp="2026-02-06T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSO" b2="230 KV" b3="4AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSO" b2="230 KV" b3="4BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DICKERSO" b2="230 KV" b3="DIC-QUI5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23035B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4350</SeqNum>
    <Name>L230.AlabamaAvenue-BuzzardPoint.23027</Name>
    <LastEdit Timestamp="2026-03-26T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALABAMA" b2="230 KV" b3="4BB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALABAMA" b2="230 KV" b3="4T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALABAMA" b2="13 KV" b3="4TS3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALABAMA" b2="13 KV" b3="4TS4B" />
      <ContingencyEquipment Action="P" Type="XF" b1="BUZZARD" b2="138 KV" b3="13T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUZZARD" b2="138 KV" b3="13TSBCB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BUZZARD" b2="230 KV" b3="23027SR" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALABAMA" b2="230 KV" b3="ALA-BUZ7" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUZZARD" b2="230 KV" b3="STAB-13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4360</SeqNum>
    <Name>L230.AlabamaAvenue-PalmersCorner.23088</Name>
    <LastEdit Timestamp="2026-01-27T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="ALABAMA" b2="230 KV" b3="136-2R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALABAMA" b2="230 KV" b3="3BB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALABAMA" b2="230 KV" b3="3T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALABAMA" b2="13 KV" b3="3TS4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALABAMA" b2="13 KV" b3="3TS5B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALABAMA" b2="230 KV" b3="6B" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALABAMA" b2="230 KV" b3="ALA-PAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="230 KV" b3="23088B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4370</SeqNum>
    <Name>L230.AlabamaAvenue-BuzzardPoint.23026</Name>
    <LastEdit Timestamp="2026-01-16T13:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALABAMA" b2="230 KV" b3="2BB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALABAMA" b2="230 KV" b3="2T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALABAMA" b2="13 KV" b3="2TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALABAMA" b2="13 KV" b3="2TS2B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BUZZARD" b2="230 KV" b3="23026SR" />
      <ContingencyEquipment Action="P" Type="XF" b1="BUZZARD" b2="138 KV" b3="8T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUZZARD" b2="138 KV" b3="8TSBCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALABAMA" b2="230 KV" b3="ALA-BUZ6" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUZZARD" b2="230 KV" b3="STAB-8T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4380</SeqNum>
    <Name>L230.AlabamaAvenue-PalmersCorner.23089</Name>
    <LastEdit Timestamp="2025-06-05T08:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="ALABAMA" b2="230 KV" b3="136-1R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALABAMA" b2="230 KV" b3="1BB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALABAMA" b2="230 KV" b3="1T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALABAMA" b2="13 KV" b3="1TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALABAMA" b2="13 KV" b3="1TS6B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALABAMA" b2="230 KV" b3="5B" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALABAMA" b2="230 KV" b3="ALA-PAL9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="230 KV" b3="23089B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4430</SeqNum>
    <Name>L230.Altoona-BearRock</Name>
    <LastEdit Timestamp="2026-02-06T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALTOONA" b2="230 KV" b3="ALT-BEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTOONA" b2="230 KV" b3="B27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTOONA" b2="230 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARROCK" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARROCK" b2="230 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4470</SeqNum>
    <Name>L230.Altoona-Raystown.2001</Name>
    <LastEdit Timestamp="2025-01-23T12:30:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALTOONA" b2="230 KV" b3="ALT-RAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTOONA" b2="230 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTOONA" b2="230 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAYSTOWN" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAYSTOWN" b2="230 KV" b3="B25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4490</SeqNum>
    <Name>L69.Atco-Tabernacle.0783</Name>
    <LastEdit Timestamp="2026-02-11T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ATCO" b2="69 KV" b3="ATC-TAB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATCO" b2="69 KV" b3="OCB P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TABERNAC" b2="69 KV" b3="OCB B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4500</SeqNum>
    <Name>L69.ATCO-Tansboro.0707</Name>
    <LastEdit Timestamp="2025-04-15T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ATCO" b2="69 KV" b3="ATC-TAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATCO" b2="69 KV" b3="OCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANSBORO" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANSBORO" b2="69 KV" b3="F CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4510</SeqNum>
    <Name>230/138.Athenia.220-1</Name>
    <LastEdit Timestamp="2024-09-19T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="2-10" />
      <ContingencyEquipment Action="X" Type="XF" b1="ATHENIA" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="220-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4520</SeqNum>
    <Name>L230.Athenia-Belleville.Z-2226</Name>
    <LastEdit Timestamp="2026-02-06T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="3-5" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATHENIA" b2="230 KV" b3="ATH-BEL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELLEVIL" b2="230 KV" b3="26KV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEVIL" b2="230 KV" b3="SECT 1-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4530</SeqNum>
    <Name>L230.Athenia-Saddlebrook.Q-2217</Name>
    <LastEdit Timestamp="2026-02-06T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="4-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATHENIA" b2="230 KV" b3="ATH-SAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SADDLEBR" b2="230 KV" b3="1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SADDLEBR" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SADDLEBR" b2="230 KV" b3="RCTR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4540</SeqNum>
    <Name>L138.Fairlawn-KullerRoad.L-1364</Name>
    <LastEdit Timestamp="2026-04-14T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAIRLAWN" b2="138 KV" b3="132-3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="FAIRLAWN" b2="26 KV" b3="23TRANSF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRLAWN" b2="138 KV" b3="SECT 1-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAIRLAWN" b2="138 KV" b3="FAI-KUL" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KULLERRD" b2="138 KV" b3="METROSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KULLERRD" b2="138 KV" b3="SECT 1-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4550</SeqNum>
    <Name>L138.Athenia-KullerRoad.J-1362</Name>
    <LastEdit Timestamp="2026-03-31T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATHENIA" b2="138 KV" b3="ATH-KUL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KULLERRD" b2="138 KV" b3="SECT 1-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4560</SeqNum>
    <Name>L138.Fairlawn-Athenia.I-1361</Name>
    <LastEdit Timestamp="2025-06-18T13:11:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="1-5" />
      <ContingencyEquipment Action="X" Type="XF" b1="ATHENIA" b2="138 KV" b3="132-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="132-3SF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATHENIA" b2="138 KV" b3="ATH-FAI" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ATHENIA" b2="26 KV" b3="GRFALLUN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ATHENIA" b2="26 KV" b3="OU GRP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAIRLAWN" b2="26 KV" b3="12TRANSF" />
      <ContingencyEquipment Action="X" Type="XF" b1="FAIRLAWN" b2="138 KV" b3="132-1T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FAIRLAWN" b2="26 KV" b3="26KV-1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FAIRLAWN" b2="26 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRLAWN" b2="138 KV" b3="SECT 1-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4570</SeqNum>
    <Name>L230.Bala-Upland.220-72 + Bala.4TR</Name>
    <LastEdit Timestamp="2025-09-08T09:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BALA" b2="230 KV" b3="250 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALA" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BALA" b2="230 KV" b3="BAL-UPLA" />
      <ContingencyEquipment Action="X" Type="XF" b1="BALA" b2="230 KV" b3="BALA4TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPLANDPE" b2="230 KV" b3="725_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4580</SeqNum>
    <Name>L230.PlymouthMeeting-Bala.220-18 + Bala.6TR</Name>
    <LastEdit Timestamp="2025-09-08T09:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BALA" b2="230 KV" b3="250 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALA" b2="13 KV" b3="6TRLS CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BALA" b2="230 KV" b3="BAL-PLY" />
      <ContingencyEquipment Action="X" Type="XF" b1="BALA" b2="230 KV" b3="BALA6TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="230 KV" b3="185 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4590</SeqNum>
    <Name>L230.PlymouthMeeting-Barbados.220-64</Name>
    <LastEdit Timestamp="2025-04-29T17:52:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BARBADOS" b2="230 KV" b3="345 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARBADOS" b2="35 KV" b3="90 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BARBADOS" b2="230 KV" b3="BAR-PLY" />
      <ContingencyEquipment Action="X" Type="XF" b1="BARBADOS" b2="230 KV" b3="BARB 9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="230 KV" b3="645 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4620</SeqNum>
    <Name>L230.BvrBrk-Glcstr.I-2235 + 230/26.Glcstr.220-3</Name>
    <LastEdit Timestamp="2025-04-11T17:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVERBR" b2="230 KV" b3="BEA-GLO" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BEAVERBR" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERBR" b2="230 KV" b3="REAC" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BEAVERBR" b2="230 KV" b3="REACTOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERBR" b2="230 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BEAVERBR" b2="230 KV" b3="TRAN  2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="1-9CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="2-9CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLOUCEST" b2="230 KV" b3="220-3 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="220-3CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="GLOUCEST" b2="26 KV" b3="R3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4640</SeqNum>
    <Name>L230.Bergen-Leonia.T-2272</Name>
    <LastEdit Timestamp="2025-09-16T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="3-13" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERGEN" b2="230 KV" b3="BER-LEO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEONIA" b2="230 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEONIA" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LEONIA" b2="230 KV" b3="T12TRANS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEONIA" b2="230 KV" b3="T3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LEONIA" b2="230 KV" b3="T34TRANS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4650</SeqNum>
    <Name>L138.Fairlawn-Bergen.M-1339</Name>
    <LastEdit Timestamp="2024-05-15T07:49:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="138 KV" b3="1-5" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERGEN" b2="138 KV" b3="BER-FAIM" />
      <ContingencyEquipment Action="S" Type="SD" b1="BERGEN" b2="138 KV" b3="REAC1339" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="138 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAIRLAWN" b2="138 KV" b3="132-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="FAIRLAWN" b2="138 KV" b3="132-2T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRLAWN" b2="138 KV" b3="SECT 1-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4660</SeqNum>
    <Name>L230.Berks-Lauschtwn+230/69.Berks.T2</Name>
    <LastEdit Timestamp="2024-09-23T10:56:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BERKS" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKS" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKS" b2="230 KV" b3="3-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKS" b2="69 KV" b3="TRAN_2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERKS" b2="230 KV" b3="BER-LAU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="230 KV" b3="BERKS3_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="230 KV" b3="BERKS3_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4670</SeqNum>
    <Name>L138.Byberry-Bluegrass.130-18</Name>
    <LastEdit Timestamp="2025-01-10T12:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEGRAS" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEGRAS" b2="13 KV" b3="6TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEGRAS" b2="138 KV" b3="905 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUEGRAS" b2="138 KV" b3="BLU 3TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUEGRAS" b2="138 KV" b3="BLU 6TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEGRAS" b2="138 KV" b3="BLU-BYB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BYBERRY" b2="138 KV" b3="150 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BYBERRY" b2="13 KV" b3="19TRLSCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BYBERRY" b2="138 KV" b3="BYB19TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4680</SeqNum>
    <Name>L138.Holmesburg-Bluegrass.130-16</Name>
    <LastEdit Timestamp="2025-01-10T12:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEGRAS" b2="138 KV" b3="165 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEGRAS" b2="138 KV" b3="BLU-HOL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLMESBU" b2="13 KV" b3="11TRLSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLMESBU" b2="138 KV" b3="705 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOLMESBU" b2="138 KV" b3="HOL11TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4690</SeqNum>
    <Name>L230.Bushkill-BloomingGr+BloomingGr.T1</Name>
    <LastEdit Timestamp="2024-09-23T10:56:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BLOOMING" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLOOMING" b2="230 KV" b3="BLO-BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLOOMING" b2="230 KV" b3="PAUPBUSH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLOOMING" b2="69 KV" b3="TRAN_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUSHKILL" b2="230 KV" b3="BLGR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4700</SeqNum>
    <Name>L230.Newlinville-Bradford.220-32 + Newlinville.2TR</Name>
    <LastEdit Timestamp="2025-01-09T14:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="230 KV" b3="270 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADFORD" b2="230 KV" b3="BRA-NEW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLINVI" b2="230 KV" b3="250 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLINVI" b2="35 KV" b3="50 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWLINVI" b2="230 KV" b3="NEW 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4710</SeqNum>
    <Name>L230.Newlinville-Bradford.220-33 + Bradford.1TR</Name>
    <LastEdit Timestamp="2025-01-09T14:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="35 KV" b3="115 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="230 KV" b3="15 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="230 KV" b3="280 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADFORD" b2="230 KV" b3="BRA-NEW3" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRADFORD" b2="230 KV" b3="BRAD1TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLINVI" b2="230 KV" b3="230 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4720</SeqNum>
    <Name>L230.PlaneBrook-Bradford.220-31</Name>
    <LastEdit Timestamp="2025-04-28T15:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="230 KV" b3="25 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="230 KV" b3="290 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADFORD" b2="230 KV" b3="BRA-PLA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="315 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4730</SeqNum>
    <Name>L230.Bridgeport-Mickleton.2315</Name>
    <LastEdit Timestamp="2025-01-17T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRIDGEPO" b2="230 KV" b3="BRI-MIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEPO" b2="230 KV" b3="BUSGCBA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEPO" b2="230 KV" b3="BUSGCBB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="BV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="ES" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4740</SeqNum>
    <Name>L230.Bridgewater-Somerville.O-2215</Name>
    <LastEdit Timestamp="2025-06-05T08:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEWA" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEWA" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIDGEWA" b2="230 KV" b3="BRI-SOM" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SOMERVIL" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOMERVIL" b2="230 KV" b3="SECT1-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SOMERVIL" b2="230 KV" b3="TRANT-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4760</SeqNum>
    <Name>L230.BrandonShores-Wagner.2346</Name>
    <LastEdit Timestamp="2026-01-07T10:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="1TR_P2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="2346CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDONS" b2="230 KV" b3="BRA-WAG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="110533CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="110535CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAGNER" b2="230 KV" b3="230-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="32-3OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="34-1OCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4770</SeqNum>
    <Name>L230.BrandonShores-Wagner.2347</Name>
    <LastEdit Timestamp="2026-01-07T10:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="23472344" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="2347CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDONS" b2="230 KV" b3="BRA-WAG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="110-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="110401" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="110402" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="110403" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAGNER" b2="230 KV" b3="230-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4790</SeqNum>
    <Name>L230.Yorkana-BrunnerIsland.1055</Name>
    <LastEdit Timestamp="2025-06-09T12:57:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNNERI" b2="230 KV" b3="BRU-YOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="YORK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="YORKWEST" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="YORKANA" b2="230 KV" b3="A26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="230 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="230 KV" b3="B121" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4810</SeqNum>
    <Name>L230.DickersonH-Doubs.23102/203</Name>
    <LastEdit Timestamp="2025-08-25T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSH" b2="230 KV" b3="412A" />
      <ContingencyEquipment Action="L" Type="LN" b1="DICKERSH" b2="230 KV" b3="DIC-DOU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ6 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4820</SeqNum>
    <Name>L230.Branchburg-EastFlemington.I-2209</Name>
    <LastEdit Timestamp="2025-07-23T16:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT 1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT 3-4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EFLEMING" b2="35 KV" b3="BK 4LSD" />
      <ContingencyEquipment Action="X" Type="XF" b1="EFLEMING" b2="230 KV" b3="BK 4TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANCHBU" b2="230 KV" b3="BRA-EFL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EFLEMING" b2="230 KV" b3="QI GC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4830</SeqNum>
    <Name>L230.PleasantValley-EastFlemington.Q-2243</Name>
    <LastEdit Timestamp="2025-07-23T16:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="EFLEMING" b2="35 KV" b3="BK 3LSD" />
      <ContingencyEquipment Action="X" Type="XF" b1="EFLEMING" b2="230 KV" b3="BK 3TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="EFLEMING" b2="230 KV" b3="EFL-PLV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EFLEMING" b2="230 KV" b3="QI GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLVY PS" b2="230 KV" b3="SECT1-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4840</SeqNum>
    <Name>L230.Siegfried-EPalm+230/69.EPalm.T1</Name>
    <LastEdit Timestamp="2024-09-23T11:15:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EPALMERT" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPALMERT" b2="230 KV" b3="EPA-SIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EPALMERT" b2="230 KV" b3="HARWSIE3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EPALMERT" b2="69 KV" b3="TRAN_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="EPALM_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="EPALM_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4860</SeqNum>
    <Name>L138.Bergen-EastRutherford.R-1344</Name>
    <LastEdit Timestamp="2025-09-16T14:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="138 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="138 KV" b3="4-5" />
      <ContingencyEquipment Action="S" Type="SD" b1="BERGEN" b2="138 KV" b3="REAC1344" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ERUTHERF" b2="138 KV" b3="132-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ERUTHERF" b2="138 KV" b3="132-1TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERUTHERF" b2="138 KV" b3="132-3H" />
      <ContingencyEquipment Action="X" Type="XF" b1="ERUTHERF" b2="138 KV" b3="132-3T" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERGEN" b2="138 KV" b3="BER-ERU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERUTHERF" b2="138 KV" b3="SECT 1-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4870</SeqNum>
    <Name>L115.EastSayre-EastTowanda.1056</Name>
    <LastEdit Timestamp="2025-03-28T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ESAYRE" b2="115 KV" b3="ESA-ETO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESAYRE" b2="115 KV" b3="ETOWANDA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B176" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4890</SeqNum>
    <Name>L230.EaglePoint-Gloucester.P-2242</Name>
    <LastEdit Timestamp="2025-06-05T08:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLEPT" b2="230 KV" b3="100" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLEPT" b2="230 KV" b3="101" />
      <ContingencyEquipment Action="L" Type="LN" b1="EAGLEPT" b2="230 KV" b3="EAG-GLO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4900</SeqNum>
    <Name>L230.Eddington-Holmesburg-Richmond.220-56</Name>
    <LastEdit Timestamp="2026-03-26T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDINGTO" b2="230 KV" b3="125 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDINGTO" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDDINGTO" b2="230 KV" b3="EDD-HOLT" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDDINGTO" b2="230 KV" b3="EDNG4TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLMESBU" b2="230 KV" b3="565" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLMESBU" b2="230 KV" b3="HOL-HOLT" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLMETAP" b2="230 KV" b3="HOLT-RIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="230 KV" b3="475 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="230 KV" b3="575 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4910</SeqNum>
    <Name>L230.Chichester-Eddystone.220-36</Name>
    <LastEdit Timestamp="2025-04-28T15:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="230 KV" b3="365 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="230 KV" b3="365 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICHEST" b2="230 KV" b3="CHI-EDD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4920</SeqNum>
    <Name>L230.Claymont-Edgemoor.23015</Name>
    <LastEdit Timestamp="2025-05-06T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYMONT" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYMONT" b2="230 KV" b3="235" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="230 KV" b3="230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYMONT" b2="230 KV" b3="CLA-EDG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4930</SeqNum>
    <Name>230/138.Edgemoor.AT20</Name>
    <LastEdit Timestamp="2026-02-11T09:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="3-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="3-6" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="230 KV" b3="AT20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4940</SeqNum>
    <Name>L230.Edgemoor-Harmony.23012</Name>
    <LastEdit Timestamp="2026-02-11T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="230 KV" b3="236" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="230 KV" b3="237" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEMOOR" b2="230 KV" b3="EDG-HAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="230 KV" b3="233" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="230 KV" b3="234" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4950</SeqNum>
    <Name>L345.Gordonrd-EdicPorter</Name>
    <LastEdit Timestamp="2025-11-18T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDIC_PTR" b2="345 KV" b3="R3510" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDIC_PTR" b2="345 KV" b3="R935" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDIC_PTR" b2="345 KV" b3="EDI-GORD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONRD" b2="345 KV" b3="G320" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONRD" b2="345 KV" b3="G330" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>4990</SeqNum>
    <Name>230/69.Kingsland.T3</Name>
    <LastEdit Timestamp="2024-10-30T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSLAN" b2="230 KV" b3="T-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSLAN" b2="230 KV" b3="T3_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5010</SeqNum>
    <Name>L230.Elimsport-Lycoming.2 + 230/69.Lycoming.2</Name>
    <LastEdit Timestamp="2025-01-21T13:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMSPOR" b2="230 KV" b3="ELI-LYC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMSPOR" b2="230 KV" b3="LYCOM2E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMSPOR" b2="230 KV" b3="LYCOM2W" />
      <ContingencyEquipment Action="X" Type="XF" b1="LYCOMING" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="TRAN2_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="TRAN2_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5070</SeqNum>
    <Name>L230.Elko-Shawville</Name>
    <LastEdit Timestamp="2025-05-20T11:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELKO" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKO" b2="230 KV" b3="ELK-SHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWVILL" b2="230 KV" b3="B83" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5080</SeqNum>
    <Name>500/138.Elroy.1TR+138/69.Elroy.2TR</Name>
    <LastEdit Timestamp="2026-02-11T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ELROYPL" b2="500 KV" b3="1 TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELROYPL" b2="138 KV" b3="2 TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELROY" b2="500 KV" b3="ELR-ELR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROYPL" b2="500 KV" b3="TRAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROYPL" b2="138 KV" b3="TRAN1DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROYPL" b2="69 KV" b3="TRAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROYPL" b2="138 KV" b3="TRAN2DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5090</SeqNum>
    <Name>230/138.Emilie.T8</Name>
    <LastEdit Timestamp="2024-08-27T09:39:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="138 KV" b3="180 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="230 KV" b3="885" />
      <ContingencyEquipment Action="X" Type="XF" b1="EMILIE" b2="230 KV" b3="EMIL8TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5100</SeqNum>
    <Name>230/138.Emilie.T7</Name>
    <LastEdit Timestamp="2024-08-27T09:39:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="138 KV" b3="175 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="230 KV" b3="775 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="EMILIE" b2="230 KV" b3="EMIL7TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5110</SeqNum>
    <Name>L115.WindyEdge-Hazelwood-Erdman.110506</Name>
    <LastEdit Timestamp="2025-12-16T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERDMAN" b2="115 KV" b3="506B_606" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERDMAN" b2="115 KV" b3="ERD-HAZ6" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAZELWOO" b2="115 KV" b3="110-8HS" />
      <ContingencyEquipment Action="S" Type="SD" b1="HAZELWOO" b2="115 KV" b3="110604" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZELWOO" b2="115 KV" b3="110604CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="HAZELWOO" b2="115 KV" b3="115KVABS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZELWOO" b2="115 KV" b3="505_506" />
      <ContingencyEquipment Action="CL" Type="CB" b1="HAZELWOO" b2="115 KV" b3="602_604" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAZELWOO" b2="115 KV" b3="HAZ-WIN6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110506" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5130</SeqNum>
    <Name>L345.ErieSouth-ErieWest.3001</Name>
    <LastEdit Timestamp="2026-02-11T10:27:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="345 KV" b3="128 B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="345 KV" b3="128 B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="345 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="345 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERIES" b2="345 KV" b3="ERI-ERI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5170</SeqNum>
    <Name>L138.Foundry-Newark.K-1337</Name>
    <LastEdit Timestamp="2025-08-26T17:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FOUNDRY" b2="138 KV" b3="FOU-NEW" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="FOUNDRY" b2="138 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOUNDRY" b2="138 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FOUNDRY" b2="138 KV" b3="TRAN T-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5180</SeqNum>
    <Name>L115.FaceRock-FiveForks.110901 + FaceRock.T1&amp;T2</Name>
    <LastEdit Timestamp="2024-05-15T08:39:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FACEROCK" b2="115 KV" b3="1" />
      <ContingencyEquipment Action="X" Type="XF" b1="FACEROCK" b2="115 KV" b3="2" />
      <ContingencyEquipment Action="S" Type="SD" b1="FACEROCK" b2="115 KV" b3="FAROFIF2" />
      <ContingencyEquipment Action="S" Type="SD" b1="FACEROCK" b2="115 KV" b3="FAROFIF3" />
      <ContingencyEquipment Action="S" Type="SD" b1="FACEROCK" b2="69 KV" b3="FAROZBR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="FIFO695T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="FIFOSBUS" />
      <ContingencyEquipment Action="L" Type="LN" b1="FACEROCK" b2="115 KV" b3="FAC-FIV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIVEFORK" b2="115 KV" b3="TIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5190</SeqNum>
    <Name>L230.Fairlawn-Waldwick.O-2267 + Fairlawn.220-1</Name>
    <LastEdit Timestamp="2026-02-11T10:08:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FAIRLAWN" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRLAWN" b2="138 KV" b3="2201 LSD" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAIRLAWN" b2="230 KV" b3="FAI-WAL" />
      <ContingencyEquipment Action="P" Type="XF" b1="WALDWICK" b2="230 KV" b3="2267PAR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WALDWICK" b2="230 KV" b3="DUM11" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WALDWICK" b2="230 KV" b3="DUM21" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WALDWICK" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="230 KV" b3="SECT2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="230 KV" b3="SECT3-4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALDWICK" b2="230 KV" b3="T-20" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALDWICK" b2="230 KV" b3="T40" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WALDWICK" b2="230 KV" b3="WALDWKSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5200</SeqNum>
    <Name>L115.Warren-Falconer.1086 [NYISO]</Name>
    <LastEdit Timestamp="2026-02-11T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FALCONER" b2="115 KV" b3="FAL-WAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALCONER" b2="115 KV" b3="R121" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="115 KV" b3="B32" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5210</SeqNum>
    <Name>L138.Emilie-Falls + 138/35.Falls.T1</Name>
    <LastEdit Timestamp="2024-10-03T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="138 KV" b3="120 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLS" b2="35 KV" b3="10 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLS" b2="138 KV" b3="215 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EMILIE" b2="138 KV" b3="EMI-FAL" />
      <ContingencyEquipment Action="X" Type="XF" b1="FALLS" b2="138 KV" b3="FALL1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5220</SeqNum>
    <Name>L138.SteelTap-Falls + 138/35.Falls.T2</Name>
    <LastEdit Timestamp="2024-10-03T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLS" b2="35 KV" b3="20 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLS" b2="138 KV" b3="215 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="FALLS" b2="138 KV" b3="FAL-STE" />
      <ContingencyEquipment Action="X" Type="XF" b1="FALLS" b2="138 KV" b3="FALL2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELTAP" b2="138 KV" b3="30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELTAP" b2="138 KV" b3="60" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5240</SeqNum>
    <Name>L345.Farragut-Marion.C-3403</Name>
    <LastEdit Timestamp="2026-02-11T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARRAGUT" b2="345 KV" b3="CB 18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION" b2="345 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARRAGUT" b2="345 KV" b3="FAR-MAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5250</SeqNum>
    <Name>L138.Bluegrass-FoxChase.130-33</Name>
    <LastEdit Timestamp="2025-09-05T10:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEGRAS" b2="138 KV" b3="335 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOXCHASE" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOXCHASE" b2="138 KV" b3="985 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEGRAS" b2="138 KV" b3="BLU-FOX" />
      <ContingencyEquipment Action="X" Type="XF" b1="FOXCHASE" b2="138 KV" b3="FOX 4TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5260</SeqNum>
    <Name>L345.Gilboa-Fraser</Name>
    <LastEdit Timestamp="2026-02-11T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRASER" b2="345 KV" b3="35-B262" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRASER" b2="345 KV" b3="B1-3562" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRASER" b2="345 KV" b3="FRA-GIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBOA" b2="345 KV" b3="3102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBOA" b2="345 KV" b3="3114" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5270</SeqNum>
    <Name>L230.Atlantic-Freneau.H1022</Name>
    <LastEdit Timestamp="2024-08-20T08:55:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B48" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATLANTIC" b2="230 KV" b3="ATL-FRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENEAU" b2="230 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENEAU" b2="230 KV" b3="B86" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRENEAU" b2="230 KV" b3="BK 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRENEAU" b2="230 KV" b3="LBK 4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5290</SeqNum>
    <Name>L230.Gilbert-GlenGardner.V-1036</Name>
    <LastEdit Timestamp="2026-01-09T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBERT" b2="230 KV" b3="B53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBERT" b2="230 KV" b3="B57" />
      <ContingencyEquipment Action="L" Type="LN" b1="GILBERT" b2="230 KV" b3="GIL-GLEG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENGARD" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENGARD" b2="230 KV" b3="B21" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5300</SeqNum>
    <Name>L230.Gilbert-Springfield</Name>
    <LastEdit Timestamp="2026-03-17T11:24:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBERT" b2="230 KV" b3="B50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBERT" b2="230 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="GILBERT" b2="230 KV" b3="GIL-SPR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRNGFLD" b2="230 KV" b3="GILB_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRNGFLD" b2="230 KV" b3="GILB_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5310</SeqNum>
    <Name>L345.Gilboa-New Scotland</Name>
    <LastEdit Timestamp="2026-02-13T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBOA" b2="345 KV" b3="3308" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBOA" b2="345 KV" b3="3314" />
      <ContingencyEquipment Action="L" Type="LN" b1="GILBOA" b2="345 KV" b3="GIL-NEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWSCOTL" b2="345 KV" b3="R1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5320</SeqNum>
    <Name>L69.Monroe-Glassboro.0729 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-21T12:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLASSBOR" b2="69 KV" b3="ABS J" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLASSBOR" b2="69 KV" b3="GLA-MON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="69 KV" b3="OCB Y" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5330</SeqNum>
    <Name>L345/230.Linden-Goethals.A-2253</Name>
    <LastEdit Timestamp="2025-05-20T14:10:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="GOETHALS" b2="345 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="GOETHALS" b2="230 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="GOETHALS" b2="13 KV" b3="1-T" />
      <ContingencyEquipment Action="P" Type="XF" b1="GOETHALS" b2="345 KV" b3="345SD01" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="7" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOETHALS" b2="230 KV" b3="GOE-LINA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GOETHALS" b2="13 KV" b3="TN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="13 KV" b3="TN1 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GOETHALS" b2="13 KV" b3="TN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="13 KV" b3="TN2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5340</SeqNum>
    <Name>L115.WarrinerPond-LaurelLake-Goudey [NYISO]</Name>
    <LastEdit Timestamp="2026-05-13T16:34:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOUDEY" b2="115 KV" b3="95202" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOUDEY" b2="115 KV" b3="GOU-LAU" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAURELL" b2="115 KV" b3="LAU-WARR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAURELL" b2="34.5 KV" b3="T X1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINER" b2="115 KV" b3="B72" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINER" b2="115 KV" b3="B89" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5350</SeqNum>
    <Name>L230.Conastone-Graceton.2323</Name>
    <LastEdit Timestamp="2025-08-26T17:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="2323 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="2323 4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRACETON" b2="230 KV" b3="2323-1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRACETON" b2="230 KV" b3="2323-2B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONASTON" b2="230 KV" b3="CNS-GRA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5360</SeqNum>
    <Name>L138.GrandPoint-Letterkenny-Grn-Roxbury</Name>
    <LastEdit Timestamp="2025-05-13T14:02:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GRANDPT" b2="138 KV" b3="GRA-LET" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDPT" b2="138 KV" b3="LETTERKE" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREE APS" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREE APS" b2="138 KV" b3="GRE-GRET" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENTAP" b2="138 KV" b3="GRE-LET" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LETTERKE" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBURY" b2="138 KV" b3="B35" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENTAP" b2="138 KV" b3="GRE-ROX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5370</SeqNum>
    <Name>L230.Northwest-Granite.2311</Name>
    <LastEdit Timestamp="2026-02-12T08:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="230 KV" b3="2311_12" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANITE" b2="230 KV" b3="GRA-NOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="2371-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="5TR-11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5380</SeqNum>
    <Name>L230.Northwest-Granite.2326 + 230/115.Granite.2</Name>
    <LastEdit Timestamp="2025-12-18T16:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="115 KV" b3="110530" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="115 KV" b3="110561-A" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRANITE" b2="230 KV" b3="230-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="230 KV" b3="2326_32" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANITE" b2="230 KV" b3="GRA-HOW3" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANITE" b2="230 KV" b3="GRA-NOR6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="2370-26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="4TR-26" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5390</SeqNum>
    <Name>L230.WestWharton-Greystone.E1045</Name>
    <LastEdit Timestamp="2024-08-20T08:57:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREYSTON" b2="230 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREYSTON" b2="230 KV" b3="GRE-WWH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="230 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="230 KV" b3="CE GCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5400</SeqNum>
    <Name>230/115.WestWharton.TX3</Name>
    <LastEdit Timestamp="2024-11-06T13:26:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WWHARTON" b2="230 KV" b3="BK 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="230 KV" b3="BK3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="115 KV" b3="BK3A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="115 KV" b3="BK3B CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5410</SeqNum>
    <Name>WestWharton.230.Cap5&amp;6</Name>
    <LastEdit Timestamp="2025-04-29T17:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="230 KV" b3="B15" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WWHARTON" b2="230 KV" b3="CAP5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="230 KV" b3="CAP5CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WWHARTON" b2="230 KV" b3="CAP6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5420</SeqNum>
    <Name>230/138.Harmony.AT20</Name>
    <LastEdit Timestamp="2026-02-11T09:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="230 KV" b3="230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARMONY" b2="230 KV" b3="AT20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5430</SeqNum>
    <Name>L230.Harwood-Siegfried</Name>
    <LastEdit Timestamp="2025-04-14T10:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HARWOOD" b2="230 KV" b3="HAR-SIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="230 KV" b3="SIEG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="230 KV" b3="SUS1-SIG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="HARWD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="HARWDTR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5440</SeqNum>
    <Name>L230.EPalm-Harwood+230/69.EPalm.T2</Name>
    <LastEdit Timestamp="2024-09-23T11:15:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EPALMERT" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPALMERT" b2="230 KV" b3="EPA-HAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EPALMERT" b2="230 KV" b3="HARWSIE3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EPALMERT" b2="69 KV" b3="TRAN_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="230 KV" b3="EPAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="230 KV" b3="SUS2-EPA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5450</SeqNum>
    <Name>L230.Harwood-Susquehanna.1</Name>
    <LastEdit Timestamp="2026-04-17T14:14:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HARWOOD" b2="230 KV" b3="HAR-SUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="230 KV" b3="SUS1-SIG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="230 KV" b3="SUSQ1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="AWSHAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="HARW1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5460</SeqNum>
    <Name>L230.Hawthorne-Waldwick.E-2257</Name>
    <LastEdit Timestamp="2026-02-11T10:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HAWTHORN" b2="230 KV" b3="HAW-WAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAWTHORN" b2="230 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAWTHORN" b2="230 KV" b3="T-20" />
      <ContingencyEquipment Action="P" Type="XF" b1="WALDWICK" b2="230 KV" b3="2257PAR" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="WALDWICK" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="230 KV" b3="SECT1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="230 KV" b3="SECT2-9" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WALDWICK" b2="230 KV" b3="TRANT-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5470</SeqNum>
    <Name>L138.Heaton-Perkiomen.130-31</Name>
    <LastEdit Timestamp="2025-01-14T15:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="138 KV" b3="315 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEATON" b2="138 KV" b3="HEA-PER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERKIOME" b2="138 KV" b3="315" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5480</SeqNum>
    <Name>L230.Woodbourne-Heaton.220-73+230/138.Heaton.T9</Name>
    <LastEdit Timestamp="2025-01-14T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="230 KV" b3="805 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="138 KV" b3="995 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="HEATON" b2="230 KV" b3="HEA 9TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEATON" b2="230 KV" b3="HEA-WOO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HEATON" b2="230 KV" b3="XFMR6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODBOUR" b2="35 KV" b3="555 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODBOUR" b2="230 KV" b3="905 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODBOUR" b2="230 KV" b3="WDB 5TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5490</SeqNum>
    <Name>L230.Whitpain-Jarrett.220-52+230/13.Jarrett.T1</Name>
    <LastEdit Timestamp="2025-05-06T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JARRET" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JARRET" b2="230 KV" b3="565 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="JARRET" b2="230 KV" b3="JAR-WHI" />
      <ContingencyEquipment Action="X" Type="XF" b1="JARRET" b2="230 KV" b3="JARRET1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="230 KV" b3="525 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5510</SeqNum>
    <Name>L230.HomerCity-Seward.2011</Name>
    <LastEdit Timestamp="2026-02-12T08:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="230 KV" b3="204" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="230 KV" b3="205" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOMERCIT" b2="230 KV" b3="HOM-SEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="230 KV" b3="B-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="230 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5520</SeqNum>
    <Name>345/230.HomerCity.TR4_N</Name>
    <LastEdit Timestamp="2024-08-01T08:45:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="230 KV" b3="210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="345 KV" b3="B307" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="345 KV" b3="B308" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOMERCIT" b2="345 KV" b3="TR4_N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5550</SeqNum>
    <Name>345/230.HomerCity.AT-S</Name>
    <LastEdit Timestamp="2025-08-14T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="230 KV" b3="211" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="345 KV" b3="B303" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="345 KV" b3="B306" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="345 KV" b3="B309" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOMERCIT" b2="23 KV" b3="DUM2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOMERCIT" b2="345 KV" b3="S.AUTO-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOMERCIT" b2="230 KV" b3="S.AUTO-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOMERCIT" b2="23 KV" b3="S.AUTO-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5580</SeqNum>
    <Name>L230.Alburtis-Hosensack.1073</Name>
    <LastEdit Timestamp="2025-08-21T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBURTME" b2="230 KV" b3="ALB-HOS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTME" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTME" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSME" b2="230 KV" b3="B24" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5590</SeqNum>
    <Name>L230.Buxmont-Hosensack.220-10+Buxmont.T2</Name>
    <LastEdit Timestamp="2024-09-23T10:57:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BUXMONT" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUXMONT" b2="69 KV" b3="TRAN_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUXMONT" b2="230 KV" b3="WHITHOS3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUXMONT" b2="230 KV" b3="BUX-HOS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="230 KV" b3="BUXM_3-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="230 KV" b3="BUXM_3-W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5600</SeqNum>
    <Name>230/115.Hosensack.T4 + 230.Hosensack.BusEast</Name>
    <LastEdit Timestamp="2025-10-03T13:29:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HOSENSME" b2="230 KV" b3="4-115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSME" b2="230 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSME" b2="230 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSME" b2="230 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSME" b2="115 KV" b3="B4B52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSME" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSME" b2="230 KV" b3="B9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSME" b2="230 KV" b3="BC182" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HOSENSME" b2="230 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HOSENSME" b2="230 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5610</SeqNum>
    <Name>L230.Hosensack-Wescosville + 230/138.Wescosvlle.T5</Name>
    <LastEdit Timestamp="2024-12-03T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HOSENSAC" b2="230 KV" b3="HOS-WES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="230 KV" b3="WESC_3-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="230 KV" b3="WESC_3-W" />
      <ContingencyEquipment Action="X" Type="XF" b1="WESCOSVI" b2="230 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="138 KV" b3="TRAN5_LO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5630</SeqNum>
    <Name>L345.Hurley-Roseton</Name>
    <LastEdit Timestamp="2026-02-13T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HURLEY" b2="345 KV" b3="30353" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HURLEY" b2="345 KV" b3="30354" />
      <ContingencyEquipment Action="L" Type="LN" b1="HURLEY" b2="345 KV" b3="HUR-ROS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSETON" b2="345 KV" b3="30356" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSETON" b2="345 KV" b3="31151" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5640</SeqNum>
    <Name>230/138.IndianRiver.AT20</Name>
    <LastEdit Timestamp="2025-11-04T16:17:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="141" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="230 KV" b3="238" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="230 KV" b3="239" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDIANRI" b2="230 KV" b3="AT-20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5650</SeqNum>
    <Name>230/138.IndianRiver.AT21</Name>
    <LastEdit Timestamp="2026-02-11T09:51:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="8010" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="8020" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDIANRI" b2="230 KV" b3="AT-21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="230 KV" b3="CS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5660</SeqNum>
    <Name>IndianRiver.230.Cap2</Name>
    <LastEdit Timestamp="2026-02-13T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="INDIANRI" b2="230 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5670</SeqNum>
    <Name>IndianRiver.SVC</Name>
    <LastEdit Timestamp="2025-02-20T13:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="230 KV" b3="9440" />
      <ContingencyEquipment Action="U" Type="GEN" b1="INDIANRI" b2="230 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5680</SeqNum>
    <Name>L230.Eddystone-IslandRoad.230-23</Name>
    <LastEdit Timestamp="2025-09-05T10:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="230 KV" b3="235 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="230 KV" b3="235 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="13 KV" b3="7TRLS CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDDYSTON" b2="230 KV" b3="EDD-ISL" />
      <ContingencyEquipment Action="X" Type="XF" b1="ISLANDRD" b2="230 KV" b3="IR 7TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5690</SeqNum>
    <Name>L138.Siegfried-Jackson.2</Name>
    <LastEdit Timestamp="2025-01-16T16:01:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EFFRTMTN" b2="138 KV" b3="EFF-GIL2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EFFRTMTN" b2="138 KV" b3="EFF-MCM2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="EFFRTMTN" b2="138 KV" b3="EMT1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EFFRTMTN" b2="138 KV" b3="EMT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GILBERTT" b2="138 KV" b3="GIL-SIE2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GILBERTT" b2="138 KV" b3="LOAD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBERTT" b2="138 KV" b3="TRAN 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PL" b2="138 KV" b3="SIEGMON2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PL" b2="138 KV" b3="SIEG_2CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACK PL" b2="138 KV" b3="JAC-MCM1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCMICHLS" b2="138 KV" b3="LOAD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCMICHLS" b2="138 KV" b3="TRAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="138 KV" b3="JACKSINS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="138 KV" b3="JACKSON" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5700</SeqNum>
    <Name>L230.Hunterstown-Jackson.1053</Name>
    <LastEdit Timestamp="2025-07-11T13:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="230 KV" b3="B320" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="230 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="230 KV" b3="B11" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTERST" b2="230 KV" b3="HUN-JAC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5710</SeqNum>
    <Name>L230.Stanton-Jenkins.1 + 230/69.Stanton.TR3</Name>
    <LastEdit Timestamp="2024-10-23T13:16:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JENKINS" b2="230 KV" b3="JEN-STA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="230 KV" b3="ST1-PALO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="230 KV" b3="STAN1" />
      <ContingencyEquipment Action="X" Type="XF" b1="STANTON" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANTON" b2="230 KV" b3="JENK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANTON" b2="69 KV" b3="TRAN_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5720</SeqNum>
    <Name>L230.Susquehanna-Palooka.1</Name>
    <LastEdit Timestamp="2025-01-06T16:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PALOOKA" b2="230 KV" b3="PAL-SUS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALOOKA" b2="230 KV" b3="SUSQ1_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALOOKA" b2="230 KV" b3="SUSQ1_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="MONTPALO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="PALO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5730</SeqNum>
    <Name>L230.HomerCity-Johnstown</Name>
    <LastEdit Timestamp="2026-02-12T08:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="230 KV" b3="201" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="230 KV" b3="202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSTOW" b2="230 KV" b3="B17" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOMERCIT" b2="230 KV" b3="HOM-JOH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5740</SeqNum>
    <Name>L230.Johnstown-Seward.2018</Name>
    <LastEdit Timestamp="2026-02-12T08:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSTOW" b2="230 KV" b3="B14" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSTOW" b2="230 KV" b3="JOH-SEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="230 KV" b3="B-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="230 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5750</SeqNum>
    <Name>230/115.Johnstown.T2</Name>
    <LastEdit Timestamp="2026-02-12T09:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSTOW" b2="115 KV" b3="B58" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSTOW" b2="230 KV" b3="B60" />
      <ContingencyEquipment Action="X" Type="XF" b1="JOHNSTOW" b2="230 KV" b3="NO2 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5790</SeqNum>
    <Name>230/115.Seward.9TX+T11</Name>
    <LastEdit Timestamp="2026-02-12T09:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SEWARD" b2="230 KV" b3="9 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="230 KV" b3="B-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="230 KV" b3="B-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="115 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="115 KV" b3="B8" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEWARD" b2="230 KV" b3="T11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5800</SeqNum>
    <Name>L230.Lewistown-Juniata</Name>
    <LastEdit Timestamp="2025-04-16T11:36:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIATA" b2="230 KV" b3="JUN-LEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="230 KV" b3="LEWI_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="230 KV" b3="LEWI_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B64" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B89" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5810</SeqNum>
    <Name>L230.Harmony-Keeney.23013</Name>
    <LastEdit Timestamp="2025-05-22T12:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="230 KV" b3="236" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="230 KV" b3="237" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="234" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="235" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARMONY" b2="230 KV" b3="HAR-KEE3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5820</SeqNum>
    <Name>L230.Harmony-Keeney.23010</Name>
    <LastEdit Timestamp="2025-05-22T12:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="230 KV" b3="234" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="230 KV" b3="235" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="240" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="241" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARMONY" b2="230 KV" b3="HAR-KEE0" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5830</SeqNum>
    <Name>230/138.Keeney.AT20</Name>
    <LastEdit Timestamp="2025-10-30T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="S" Type="SD" b1="KEENEY" b2="138 KV" b3="13822" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEENEY" b2="230 KV" b3="AT20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5840</SeqNum>
    <Name>L230.Keeney-RedLion.23011</Name>
    <LastEdit Timestamp="2025-05-22T12:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEENEY" b2="230 KV" b3="KEE-RED2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="243" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="244" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5850</SeqNum>
    <Name>L230.Green-Keeney.23009</Name>
    <LastEdit Timestamp="2026-04-29T17:15:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENDPL" b2="230 KV" b3="230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENDPL" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="239" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="240" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENDPL" b2="230 KV" b3="GRE-KEEN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5860</SeqNum>
    <Name>L230.Keeney-Steele.23001</Name>
    <LastEdit Timestamp="2025-05-23T14:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="237" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="238" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEENEY" b2="230 KV" b3="KEE-STE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="230 KV" b3="257" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="230 KV" b3="9210" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5870</SeqNum>
    <Name>500/230.Keystone.T4</Name>
    <LastEdit Timestamp="2026-02-12T09:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="KEYSTONE" b2="500 KV" b3="4 TX-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEYSTONE" b2="230 KV" b3="4 TX-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEYSTONE" b2="20 KV" b3="4 TX-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="230 KV" b3="B80" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B9" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="KEYSTONE" b2="500 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEYSTONE" b2="20 KV" b3="SS #4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5880</SeqNum>
    <Name>500/230.Keystone.T3</Name>
    <LastEdit Timestamp="2026-03-04T00:50:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="500 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="230 KV" b3="B70" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEYSTONE" b2="500 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5890</SeqNum>
    <Name>L230.Portland-Kittatinny.V1010</Name>
    <LastEdit Timestamp="2026-03-27T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTATIN" b2="230 KV" b3="B119" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KITTATIN" b2="34 KV" b3="BK 1LSD" />
      <ContingencyEquipment Action="X" Type="XF" b1="KITTATIN" b2="230 KV" b3="BK 1TR" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="KITTATIN" b2="230 KV" b3="CAP3" />
      <ContingencyEquipment Action="L" Type="LN" b1="KITTATIN" b2="230 KV" b3="KIT-POR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTATIN" b2="230 KV" b3="VT AC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTLAND" b2="230 KV" b3="B101012" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5900</SeqNum>
    <Name>L230.WashingtonAve-Kingsland-NJTMeadows</Name>
    <LastEdit Timestamp="2026-04-29T14:17:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="KINGSLAN" b2="230 KV" b3="DUM" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KINGSLAN" b2="230 KV" b3="DUM4" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGSLAN" b2="230 KV" b3="KIN-NJT" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGSLAN" b2="230 KV" b3="KIN-WASH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSLAN" b2="230 KV" b3="T-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSLAN" b2="230 KV" b3="T-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NJTMEADO" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NJTMEADO" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WASHAVE" b2="230 KV" b3="1-2CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WASHAVE" b2="230 KV" b3="T-20LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5920</SeqNum>
    <Name>L230.Smithburg-Larrabee.H2008+500/230.Smithburg.T4</Name>
    <LastEdit Timestamp="2025-06-02T12:54:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRABEE" b2="230 KV" b3="B48" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRABEE" b2="230 KV" b3="B57" />
      <ContingencyEquipment Action="L" Type="LN" b1="LARRABEE" b2="230 KV" b3="LAR-SMIH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHBUR" b2="230 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHBUR" b2="230 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHBUR" b2="500 KV" b3="B5" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMITHBUR" b2="500 KV" b3="BK 4 50" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5930</SeqNum>
    <Name>L230.Smithburg-Larrabee.D2004</Name>
    <LastEdit Timestamp="2025-06-05T08:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRABEE" b2="230 KV" b3="B 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRABEE" b2="230 KV" b3="B37" />
      <ContingencyEquipment Action="L" Type="LN" b1="LARRABEE" b2="230 KV" b3="LAR-SMID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHBUR" b2="230 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHBUR" b2="230 KV" b3="ED GC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5940</SeqNum>
    <Name>L230.Lakewood-Larrabee.Z2026</Name>
    <LastEdit Timestamp="2024-11-20T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEWOOD" b2="230 KV" b3="ZA GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEWOOD" b2="230 KV" b3="ZG GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRABEE" b2="230 KV" b3="B 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRABEE" b2="230 KV" b3="B9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LARRABEE" b2="230 KV" b3="BK 8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LARRABEE" b2="230 KV" b3="BK12" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEWOOD" b2="230 KV" b3="LAK-LAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5950</SeqNum>
    <Name>L230.Atlantic-Larrabee.R1032</Name>
    <LastEdit Timestamp="2026-02-12T09:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B34" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATLANTIC" b2="230 KV" b3="ATL-LAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRABEE" b2="230 KV" b3="B60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRABEE" b2="230 KV" b3="B63" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5960</SeqNum>
    <Name>L230.Clarksville-Lawrence.D-1018</Name>
    <LastEdit Timestamp="2026-02-17T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLARKSVI" b2="230 KV" b3="CLARKSP" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CLARKSVI" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKSVI" b2="230 KV" b3="SECT1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="2-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="5-6 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLARKSVI" b2="230 KV" b3="CLA-LAW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5970</SeqNum>
    <Name>L230.Lawrence-Hopewell.F-1020</Name>
    <LastEdit Timestamp="2025-02-20T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL1" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL1" b2="230 KV" b3="1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="3-4 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPEWEL1" b2="230 KV" b3="HOP-LAW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>5980</SeqNum>
    <Name>L230.Bradford-Lenape.220-48</Name>
    <LastEdit Timestamp="2026-04-21T15:27:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="230 KV" b3="240 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LENAPE" b2="35 KV" b3="115 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LENAPE" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADFORD" b2="230 KV" b3="BRA-LEN" />
      <ContingencyEquipment Action="X" Type="XF" b1="LENAPE" b2="230 KV" b3="LEN1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6000</SeqNum>
    <Name>L230.Aldene-SpringfieldRoad.G-2285</Name>
    <LastEdit Timestamp="2024-12-16T16:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALDENE" b2="230 KV" b3="4-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALDENE" b2="230 KV" b3="ALD-SPRG" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ALDENE" b2="230 KV" b3="REACTOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALDENE" b2="230 KV" b3="SECT 2-6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALDENE" b2="230 KV" b3="T-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGRD" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SPRINGRD" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGRD" b2="230 KV" b3="T20CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6010</SeqNum>
    <Name>L230.Aldene-Warinanco.N-2240</Name>
    <LastEdit Timestamp="2025-05-12T05:10:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALDENE" b2="230 KV" b3="1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALDENE" b2="230 KV" b3="4-6" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ALDENE" b2="230 KV" b3="DUM14169" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALDENE" b2="230 KV" b3="ALD-WAR" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="WARINANC" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARINANC" b2="230 KV" b3="SECT1-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WARINANC" b2="230 KV" b3="TRAN T-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6020</SeqNum>
    <Name>L138.Hogan-JonesCreek-Aladdin</Name>
    <LastEdit Timestamp="2025-08-13T13:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALADDIN" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALADDIN" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOGAN" b2="138 KV" b3="AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOGAN" b2="138 KV" b3="AB1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JONESCRE" b2="138 KV" b3="HOG-JON" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALADDIN" b2="138 KV" b3="ALA-JON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JONESCRE" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6050</SeqNum>
    <Name>L230.Buckingham-Linton.220-21</Name>
    <LastEdit Timestamp="2025-05-06T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKINGH" b2="230 KV" b3="240 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINTON" b2="35 KV" b3="225 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINTON" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKINGH" b2="230 KV" b3="BUC-LIN" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINTON" b2="230 KV" b3="LIN 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6060</SeqNum>
    <Name>L230.Cookstown-Lumberton.T2246</Name>
    <LastEdit Timestamp="2025-06-06T17:04:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOKSTOW" b2="230 KV" b3="B37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOKSTOW" b2="230 KV" b3="B66" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMBERTO" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMBERTO" b2="230 KV" b3="220-6CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOKSTOW" b2="230 KV" b3="COO-LUM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMBERTO" b2="230 KV" b3="SECT1-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6070</SeqNum>
    <Name>L230.Alburtis-Lyons.1021</Name>
    <LastEdit Timestamp="2025-08-21T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBURTME" b2="230 KV" b3="ALB-LYO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTME" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTME" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYONS" b2="230 KV" b3="103172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYONS" b2="230 KV" b3="B371CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6080</SeqNum>
    <Name>L230.NorthHershey-NorthTemple.1001</Name>
    <LastEdit Timestamp="2025-11-21T12:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NHERSHEY" b2="230 KV" b3="109982" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHERSHEY" b2="230 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="NHERSHEY" b2="230 KV" b3="NHE-NTE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTEMPLE" b2="230 KV" b3="070112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTEMPLE" b2="230 KV" b3="100112" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6090</SeqNum>
    <Name>L230.Lakewood-LeisureVillage.U2021</Name>
    <LastEdit Timestamp="2025-10-10T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEWOOD" b2="230 KV" b3="B37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEWOOD" b2="230 KV" b3="B39" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAKEWOOD" b2="230 KV" b3="TR6" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEWOOD" b2="230 KV" b3="LAK-LEI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEISUREV" b2="230 KV" b3="UC CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6100</SeqNum>
    <Name>L230.Lakewood-LeisureVillage.D2030</Name>
    <LastEdit Timestamp="2025-06-06T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEWOOD" b2="230 KV" b3="DB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEWOOD" b2="230 KV" b3="DK" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEWOOD" b2="230 KV" b3="LAK-LEI0" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEISUREV" b2="230 KV" b3="BANK 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEISUREV" b2="230 KV" b3="BK 4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEISUREV" b2="230 KV" b3="DA CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6110</SeqNum>
    <Name>L230.Lakewood-Larrabee.K2011</Name>
    <LastEdit Timestamp="2024-10-29T16:29:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEWOOD" b2="230 KV" b3="DK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEWOOD" b2="230 KV" b3="KG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRABEE" b2="230 KV" b3="B162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRABEE" b2="230 KV" b3="B51_X" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEWOOD" b2="230 KV" b3="LAK-LAR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6120</SeqNum>
    <Name>L230.Manitou-LeisureVillage.A2027</Name>
    <LastEdit Timestamp="2026-02-12T09:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEISUREV" b2="230 KV" b3="DA CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEISUREV" b2="230 KV" b3="LEI-MANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="230 KV" b3="AO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="230 KV" b3="AV" />
      <ContingencyEquipment Action="X" Type="XF" b1="MANITOU" b2="230 KV" b3="BK 7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="35 KV" b3="BK7LOBKR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6130</SeqNum>
    <Name>L230.Manitou-LeisureVillage.C2029</Name>
    <LastEdit Timestamp="2025-06-06T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEISUREV" b2="230 KV" b3="BK 1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEISUREV" b2="230 KV" b3="BK 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEISUREV" b2="230 KV" b3="LEI-MANU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEISUREV" b2="230 KV" b3="UC CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="230 KV" b3="B51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="230 KV" b3="B55" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6140</SeqNum>
    <Name>L230.OysterCreek-Manitou.O1029</Name>
    <LastEdit Timestamp="2025-03-28T15:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="230 KV" b3="AO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="230 KV" b3="B27" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANITOU" b2="230 KV" b3="MAN-OYSO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OYSTERCR" b2="230 KV" b3="B84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OYSTERCR" b2="230 KV" b3="B87" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6150</SeqNum>
    <Name>L230.OysterCreek-Manitou.N1028</Name>
    <LastEdit Timestamp="2025-04-01T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="230 KV" b3="B51" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANITOU" b2="230 KV" b3="MAN-OYSN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="230 KV" b3="VN GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OYSTERCR" b2="230 KV" b3="B91" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OYSTERCR" b2="230 KV" b3="B94" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6160</SeqNum>
    <Name>L230.OtterCrk-Manor-SafeHarbor.2302</Name>
    <LastEdit Timestamp="2026-03-09T12:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MANOR" b2="230 KV" b3="MAN-SAF1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="230 KV" b3="MLWD_S" />
      <ContingencyEquipment Action="S" Type="SD" b1="MANOR" b2="230 KV" b3="SAFEHAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="230 KV" b3="WHEM_2-S" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANOR" b2="230 KV" b3="MAN-OTTC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTCRKPL" b2="230 KV" b3="MANO_NCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTCRKPL" b2="230 KV" b3="MANO_SCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SAFEHARB" b2="230 KV" b3="2301" />
      <ContingencyEquipment Action="X" Type="XF" b1="SAFEHARB" b2="230 KV" b3="2302" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAFEHARB" b2="13 KV" b3="TR1-NE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAFEHARB" b2="13 KV" b3="TR1-NW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAFEHARB" b2="13 KV" b3="TR1-SE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SAFEHARB" b2="13 KV" b3="TR1-SW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAFEHARB" b2="13 KV" b3="TR2-NE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAFEHARB" b2="13 KV" b3="TR2-NW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAFEHARB" b2="13 KV" b3="TR2-SE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SAFEHARB" b2="13 KV" b3="TR2-SW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAFEHARB" b2="230 KV" b3="TRAN2301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAFEHARB" b2="230 KV" b3="TRAN2302" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6170</SeqNum>
    <Name>L230.Graceton-Manor-SafeHarbor.2303 + SfHrbr.U8-12</Name>
    <LastEdit Timestamp="2024-09-12T15:26:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRACETON" b2="230 KV" b3="2303 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRACETON" b2="230 KV" b3="2313-03" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRACETON" b2="230 KV" b3="GRA-MANO" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANOR" b2="230 KV" b3="MAN-SAF2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="230 KV" b3="MLWD_N" />
      <ContingencyEquipment Action="S" Type="SD" b1="MANOR" b2="230 KV" b3="SAFEHAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="230 KV" b3="WHEM_2-N" />
      <ContingencyEquipment Action="X" Type="XF" b1="SAFEHARB" b2="230 KV" b3="2303" />
      <ContingencyEquipment Action="X" Type="XF" b1="SAFEHARB" b2="230 KV" b3="2304" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAFEHARB" b2="230 KV" b3="TRAN2303" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAFEHARB" b2="230 KV" b3="TRAN2304" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SAFEHARB" b2="13 KV" b3="UNIT10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SAFEHARB" b2="13 KV" b3="UNIT11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SAFEHARB" b2="13 KV" b3="UNIT12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SAFEHARB" b2="13 KV" b3="UNIT8" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SAFEHARB" b2="13 KV" b3="UNIT9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6230</SeqNum>
    <Name>L230.Siegfried-Klecknersville</Name>
    <LastEdit Timestamp="2026-05-21T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KLECKNER" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KLECKNER" b2="230 KV" b3="B10" />
      <ContingencyEquipment Action="L" Type="LN" b1="KLECKNER" b2="230 KV" b3="KLE-SIEG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="KLEC_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="KLEC_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6240</SeqNum>
    <Name>L230.Siegfried-MartinsCreek.1</Name>
    <LastEdit Timestamp="2026-02-13T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="2030SIE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARTINSC" b2="230 KV" b3="MAR-SIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="SIEG_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="MACR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="MACR1TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6260</SeqNum>
    <Name>L138.Eddystone-Master.130-43</Name>
    <LastEdit Timestamp="2026-02-13T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="138 KV" b3="435 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASTER" b2="138 KV" b3="435 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDDYSTON" b2="138 KV" b3="EDD-MAS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6270</SeqNum>
    <Name>230/138.Master.8TR</Name>
    <LastEdit Timestamp="2025-05-23T14:57:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MASTER" b2="138 KV" b3="825 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASTER" b2="230 KV" b3="885" />
      <ContingencyEquipment Action="X" Type="XF" b1="MASTER" b2="230 KV" b3="MAS 8TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6280</SeqNum>
    <Name>L230.Master-Parrish.220-45</Name>
    <LastEdit Timestamp="2025-01-21T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MASTER" b2="230 KV" b3="455 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="MASTER" b2="230 KV" b3="MAS-PAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARRISH" b2="230 KV" b3="805 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARRISH" b2="230 KV" b3="825 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PARRISH" b2="230 KV" b3="PAR 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6290</SeqNum>
    <Name>L230.BrunnerIsland-MiddletownJct.1056</Name>
    <LastEdit Timestamp="2026-06-03T10:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNNERI" b2="230 KV" b3="BRU-MID6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="MIDDLET1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B105682" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B160" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6300</SeqNum>
    <Name>L230.BrunnerIsland-MiddletownJct.1005</Name>
    <LastEdit Timestamp="2026-03-17T15:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNNERI" b2="230 KV" b3="BRU-MID5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="MIJU2_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="MIJU2_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B100542" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B173" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6310</SeqNum>
    <Name>L230.Hummelstown-MiddleJct.1098</Name>
    <LastEdit Timestamp="2025-11-03T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HUMMELST" b2="230 KV" b3="HUM-MID8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="230 KV" b3="MIJU_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="230 KV" b3="MIJU_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B109842" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B134" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6320</SeqNum>
    <Name>L230.TMI-MiddletownJunction.1091</Name>
    <LastEdit Timestamp="2024-11-27T11:14:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B109142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B137" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDDLJCT" b2="230 KV" b3="MID-TMI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="230 KV" b3="109102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="230 KV" b3="109112" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6330</SeqNum>
    <Name>L230.TMI-MiddletownJunction.1092</Name>
    <LastEdit Timestamp="2026-03-27T09:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B154" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B157" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDDLJCT" b2="230 KV" b3="MID-TMI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="230 KV" b3="109202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="230 KV" b3="925102" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6340</SeqNum>
    <Name>L230.Mercer-Kuser-LawrenceSub-Lawrence.A-2201</Name>
    <LastEdit Timestamp="2025-04-08T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KUSERRD" b2="230 KV" b3="KUS-LAW" />
      <ContingencyEquipment Action="L" Type="LN" b1="KUSERRD" b2="230 KV" b3="KUS-MERA" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KUSERRD" b2="230 KV" b3="T1-2TRAN" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KUSERRD" b2="230 KV" b3="T3-4TRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KUSERRD" b2="230 KV" b3="TRAN T-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KUSERRD" b2="230 KV" b3="TRAN T-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="1-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="9-10 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAWRENCE" b2="230 KV" b3="LAW-LAWA" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LAWRESUB" b2="230 KV" b3="T1020TRS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LAWRESUB" b2="230 KV" b3="T3040TRS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAWRESUB" b2="230 KV" b3="TRANT-10" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAWRESUB" b2="230 KV" b3="TRANT-30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCER" b2="230 KV" b3="A-2201" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6360</SeqNum>
    <Name>L69.Lamb-Mantua.0785</Name>
    <LastEdit Timestamp="2025-05-02T13:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMB" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAMB" b2="69 KV" b3="LAM-MANT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANTUA" b2="69 KV" b3="OCB B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6370</SeqNum>
    <Name>L230.Mickleton-Monroe.2304</Name>
    <LastEdit Timestamp="2025-04-23T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MICKLETO" b2="230 KV" b3="MIC-MON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="230 KV" b3="BUSOCBBB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="230 KV" b3="II" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6380</SeqNum>
    <Name>230/138.Monroe.T3 (AE)</Name>
    <LastEdit Timestamp="2026-02-12T09:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="230 KV" b3="II" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="230 KV" b3="JJ" />
      <ContingencyEquipment Action="X" Type="XF" b1="MONR AE" b2="230 KV" b3="MON #3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="138 KV" b3="XFMROCBN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="138 KV" b3="XFMROCBP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6390</SeqNum>
    <Name>L230.Morton-Middletown.220-66 + 230/34.Middltwn.T4</Name>
    <LastEdit Timestamp="2026-02-13T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MIDD PE" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD PE" b2="35 KV" b3="45" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD PE" b2="230 KV" b3="895" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD PE" b2="230 KV" b3="945" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDD PE" b2="230 KV" b3="MID-MOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORTON" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORTON" b2="230 KV" b3="565 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MORTON" b2="230 KV" b3="MORTON1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6400</SeqNum>
    <Name>L230.Milford-Steele.23076</Name>
    <LastEdit Timestamp="2026-02-13T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="230 KV" b3="9310" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="230 KV" b3="9320" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILFORD" b2="230 KV" b3="MIL-STE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="230 KV" b3="9230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="230 KV" b3="9240" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6410</SeqNum>
    <Name>L115.WindyEdge-Erdman.110507</Name>
    <LastEdit Timestamp="2025-12-03T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERDMAN" b2="115 KV" b3="507-557" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERDMAN" b2="115 KV" b3="ERD-WIN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110507" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6430</SeqNum>
    <Name>L115.WindyEdge-Erdman.110508</Name>
    <LastEdit Timestamp="2026-06-05T12:23:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ERDMAN" b2="115 KV" b3="ERD-WIN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERDMAN" b2="115 KV" b3="GBB6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERDMAN" b2="115 KV" b3="GBT6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110508" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6440</SeqNum>
    <Name>230/69.Monroe.T5 (AE)</Name>
    <LastEdit Timestamp="2026-02-12T09:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="230 KV" b3="BUSOCBAA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="230 KV" b3="LL" />
      <ContingencyEquipment Action="X" Type="XF" b1="MONR AE" b2="230 KV" b3="MON #5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="69 KV" b3="XFMROCBS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6450</SeqNum>
    <Name>230/69.Monroe.T6 (AE)</Name>
    <LastEdit Timestamp="2026-02-12T09:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="230 KV" b3="BUSOCBBB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="230 KV" b3="BUSOCBCC" />
      <ContingencyEquipment Action="X" Type="XF" b1="MONR AE" b2="230 KV" b3="MON #6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="69 KV" b3="XFMROCBT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6460</SeqNum>
    <Name>L230.NewFreedom-Monroe.2305</Name>
    <LastEdit Timestamp="2026-02-13T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="230 KV" b3="BUSOCBCC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="230 KV" b3="BUSOCBDD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONR AE" b2="230 KV" b3="MON-NEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="230 2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="230 3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6470</SeqNum>
    <Name>L138.Jackson-TannersV-BartonV-Stroudsburg-Monroe.2</Name>
    <LastEdit Timestamp="2026-05-12T09:49:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRTNSVIL" b2="138 KV" b3="7844" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BRTNSVIL" b2="138 KV" b3="DUM1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACK PL" b2="138 KV" b3="JAC-TAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PL" b2="138 KV" b3="MONR CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PL" b2="138 KV" b3="SIEGMONR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR PL" b2="138 KV" b3="JKSN CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONR PL" b2="138 KV" b3="MON-STR" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRTNSVIL" b2="138 KV" b3="BAR-NST" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NSTRDSBG" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSTRDSBG" b2="138 KV" b3="CAP1CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NSTRDSBG" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="STRDSBG" b2="138 KV" b3="STR-NST" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STRDSBG" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRTNSVIL" b2="138 KV" b3="BAR-TAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TANNERSV" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6480</SeqNum>
    <Name>L230.Foxhill-MonroePL.1018</Name>
    <LastEdit Timestamp="2025-10-24T12:57:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOXHILL" b2="230 KV" b3="B19" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOXHILL" b2="230 KV" b3="FOX-MON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR PL" b2="230 KV" b3="FOXHILTI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6490</SeqNum>
    <Name>L230.MartinsCreek-Monroe + 230/138.Monr.T2</Name>
    <LastEdit Timestamp="2026-02-13T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="GBRTMONR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="MONR" />
      <ContingencyEquipment Action="X" Type="XF" b1="MONR PL" b2="230 KV" b3="2 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR PL" b2="230 KV" b3="FOXHILTI" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARTINSC" b2="230 KV" b3="MAR-MON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR PL" b2="138 KV" b3="TRAN2LS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6510</SeqNum>
    <Name>L230.Whippany-StonyBrook-Morristown.B1016</Name>
    <LastEdit Timestamp="2025-11-12T10:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISTO" b2="230 KV" b3="B83" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MORRISTO" b2="230 KV" b3="BK 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORRISTO" b2="230 KV" b3="MOR-STO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STON JC" b2="230 KV" b3="BK 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STON JC" b2="230 KV" b3="STO-WHI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="230 KV" b3="B34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6520</SeqNum>
    <Name>L230.ETowanda-SctchHllw-Grover-Marshall</Name>
    <LastEdit Timestamp="2025-04-24T11:12:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="230 KV" b3="B31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="230 KV" b3="B41" />
      <ContingencyEquipment Action="L" Type="LN" b1="ETOWANDA" b2="230 KV" b3="ETO-SCO" />
      <ContingencyEquipment Action="X" Type="XF" b1="GROVER" b2="230 KV" b3="1TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GROVER" b2="34 KV" b3="1TXB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GROVER" b2="230 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GROVER" b2="230 KV" b3="GRO-MARS" />
      <ContingencyEquipment Action="L" Type="LN" b1="GROVER" b2="230 KV" b3="GRO-SCO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHALL" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHALL" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCOTCHHO" b2="230 KV" b3="SCOTCH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6540</SeqNum>
    <Name>L230.Moshannon-Shawville.2019</Name>
    <LastEdit Timestamp="2025-04-25T17:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSHANON" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSHANON" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOSHANON" b2="230 KV" b3="MOS-SHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWVILL" b2="230 KV" b3="B71" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6550</SeqNum>
    <Name>L230.SusquehannaT10-Mountain</Name>
    <LastEdit Timestamp="2025-01-17T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MOUN UGI" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="230 KV" b3="23010" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66230" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUN UGI" b2="230 KV" b3="MOU-T10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQT10" b2="230 KV" b3="MOUNT10T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQT10" b2="230 KV" b3="MOUNTAIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6560</SeqNum>
    <Name>L230.Brighton-MtZion-QuinceOrchard.23125/23025</Name>
    <LastEdit Timestamp="2026-02-12T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="230 KV" b3="4AB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIGHTON" b2="230 KV" b3="BRI-MTZ5" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTZION" b2="230 KV" b3="MTZ-NOR9" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTZION" b2="230 KV" b3="MTZ-QUI5" />
      <ContingencyEquipment Action="X" Type="XF" b1="NORBECK" b2="230 KV" b3="158-4T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORBECK" b2="69 KV" b3="4TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORBECK" b2="69 KV" b3="4TS4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23025B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6570</SeqNum>
    <Name>L230.QuinceOrchard-BellsMillRoad.23031</Name>
    <LastEdit Timestamp="2024-10-17T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="69 KV" b3="11TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="69 KV" b3="11TS2B" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLSMIL" b2="230 KV" b3="121-11T" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLSMIL" b2="230 KV" b3="121-6T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K9" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BELLSMIL" b2="230 KV" b3="4 CAP" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLSMIL" b2="230 KV" b3="BEL-QUI1" />
      <ContingencyEquipment Action="X" Type="XF" b1="QUINCEOR" b2="230 KV" b3="118-2T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23022B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23032B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="69 KV" b3="69K4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="69 KV" b3="69K5B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6580</SeqNum>
    <Name>L230.Brighton-MtZion-QuinceOrchard.23122/23022</Name>
    <LastEdit Timestamp="2026-02-12T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="230 KV" b3="1AB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIGHTON" b2="230 KV" b3="BRI-MTZ2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTZION" b2="230 KV" b3="MTZ-NOR8" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTZION" b2="230 KV" b3="MTZ-QUI2" />
      <ContingencyEquipment Action="X" Type="XF" b1="NORBECK" b2="230 KV" b3="158-2T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORBECK" b2="69 KV" b3="2TS2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORBECK" b2="69 KV" b3="2TS3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23022B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6590</SeqNum>
    <Name>L230.Brighton-MtZion-QuinceOrchard.23123/23023</Name>
    <LastEdit Timestamp="2026-02-12T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="230 KV" b3="3AB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIGHTON" b2="230 KV" b3="BRI-MTZ3" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTZION" b2="230 KV" b3="MTZ-NOR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTZION" b2="230 KV" b3="MTZ-QUI3" />
      <ContingencyEquipment Action="X" Type="XF" b1="NORBECK" b2="230 KV" b3="158-3T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORBECK" b2="69 KV" b3="3TS3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORBECK" b2="69 KV" b3="3TS4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23023B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6600</SeqNum>
    <Name>L230.QuinceOrchard-BellsMillRoad.23028</Name>
    <LastEdit Timestamp="2024-10-14T13:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="BELLSMIL" b2="230 KV" b3="1 CAP" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLSMIL" b2="230 KV" b3="121-14T" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLSMIL" b2="230 KV" b3="121-2T" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLSMIL" b2="230 KV" b3="121-4T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="69 KV" b3="14TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="69 KV" b3="14TS4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="34 KV" b3="2TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="34 KV" b3="2TS4B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLSMIL" b2="230 KV" b3="BEL-QUI8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23028B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6610</SeqNum>
    <Name>L230.WaughChapel-JerichoPark-Bowie.2340</Name>
    <LastEdit Timestamp="2025-10-06T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="230 KV" b3="2340B" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23016_50" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23016_51" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23025_50" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23025_51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JERICHOP" b2="230 KV" b3="230-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JERICHOP" b2="230 KV" b3="2340-50" />
      <ContingencyEquipment Action="S" Type="SD" b1="JERICHOP" b2="230 KV" b3="2340SD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOWIE" b2="230 KV" b3="BOW-JER0" />
      <ContingencyEquipment Action="L" Type="LN" b1="JERICHOP" b2="230 KV" b3="JER-WAU0" />
      <ContingencyEquipment Action="CL" Type="CB" b1="JERICHOP" b2="230 KV" b3="TIECB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="2327_40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="2340OCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6620</SeqNum>
    <Name>L230.Hummelstown-NHershey + Hummel.T2</Name>
    <LastEdit Timestamp="2025-12-16T15:43:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HUMMELST" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="230 KV" b3="NHER_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="230 KV" b3="NHER_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="69 KV" b3="TRAN_2-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="69 KV" b3="TRAN_2-W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHERSHEY" b2="230 KV" b3="B18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHERSHEY" b2="230 KV" b3="B92" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUMMELST" b2="230 KV" b3="HUM-NHE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6630</SeqNum>
    <Name>L230.MiddletownJunction-WillowDrive-Copperstone</Name>
    <LastEdit Timestamp="2025-12-04T16:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COPPERST" b2="230 KV" b3="COP-WIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="230 KV" b3="DAUPMIJU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="230 KV" b3="MIJU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDDLJCT" b2="230 KV" b3="MIDJ-WIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILLOWDR" b2="230 KV" b3="SUNOCO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6640</SeqNum>
    <Name>L230.Hillsdale-NewMilford.V-2222</Name>
    <LastEdit Timestamp="2024-12-18T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWMILFR" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWMILFR" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLSDAL" b2="230 KV" b3="HIL-NEW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6650</SeqNum>
    <Name>L230.Maywood-Saddlebrook.G-2259</Name>
    <LastEdit Timestamp="2026-02-17T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MAYWOOD" b2="230 KV" b3="MAY-SAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYWOOD" b2="230 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAYWOOD" b2="13 KV" b3="TR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAYWOOD" b2="13 KV" b3="TR4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SADDLEBR" b2="230 KV" b3="1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SADDLEBR" b2="230 KV" b3="SECT 1-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6660</SeqNum>
    <Name>L230.Master-NorthPhiladelphia.220-44</Name>
    <LastEdit Timestamp="2026-03-12T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MASTER" b2="230 KV" b3="445 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="MASTER" b2="230 KV" b3="MAS-NPH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="230 KV" b3="875 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="230 KV" b3="885" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6670</SeqNum>
    <Name>L230.NorthPhiladelphia-Waneeta.220-49</Name>
    <LastEdit Timestamp="2025-11-24T15:12:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="230 KV" b3="655 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="230 KV" b3="775_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="230 KV" b3="875 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="NPHILADE" b2="230 KV" b3="NPH-WAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="230 KV" b3="495 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6680</SeqNum>
    <Name>L230.Hosensack-NorthTemple.1003</Name>
    <LastEdit Timestamp="2025-03-17T14:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSME" b2="230 KV" b3="B100342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTEMPLE" b2="230 KV" b3="070312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTEMPLE" b2="230 KV" b3="100312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTEMPLE" b2="69 KV" b3="4B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOSENSME" b2="230 KV" b3="HOS-NTE" />
      <ContingencyEquipment Action="X" Type="XF" b1="NTEMPLE" b2="230 KV" b3="NT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6690</SeqNum>
    <Name>L230.NorthTemple-Northkill</Name>
    <LastEdit Timestamp="2025-03-05T16:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHKILL" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHKILL" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTEMPLE" b2="230 KV" b3="070112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTEMPLE" b2="230 KV" b3="100312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTEMPLE" b2="69 KV" b3="6B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="NRTHKILL" b2="230 KV" b3="NKI-NTE" />
      <ContingencyEquipment Action="X" Type="XF" b1="NTEMPLE" b2="230 KV" b3="NT6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6700</SeqNum>
    <Name>L230.NWales-Whitpain.220-16 + 230/35.NWales.TR1</Name>
    <LastEdit Timestamp="2026-02-13T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NWALES" b2="35 KV" b3="10 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWALES" b2="230 KV" b3="905 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="NWALES" b2="230 KV" b3="NW 1TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="230 KV" b3="165 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="NWALES" b2="230 KV" b3="NWA-WHI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6710</SeqNum>
    <Name>L138.Byberry-Neshaminy.130-17</Name>
    <LastEdit Timestamp="2026-02-12T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BYBERRY" b2="138 KV" b3="120 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BYBERRY" b2="13 KV" b3="17TRLSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BYBERRY" b2="13 KV" b3="20TRLSCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BYBERRY" b2="138 KV" b3="BYB17TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="BYBERRY" b2="138 KV" b3="BYB20TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NESHAMIN" b2="138 KV" b3="175" />
      <ContingencyEquipment Action="L" Type="LN" b1="BYBERRY" b2="138 KV" b3="BYB-NES" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6720</SeqNum>
    <Name>L138.Emilie-Neshaminy.130-25</Name>
    <LastEdit Timestamp="2025-09-08T09:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="138 KV" b3="130 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NESHAMIN" b2="138 KV" b3="755" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NESHAMIN" b2="138 KV" b3="785" />
      <ContingencyEquipment Action="L" Type="LN" b1="EMILIE" b2="138 KV" b3="EMI-NES" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="NESHAMIN" b2="138 KV" b3="T15" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="NESHAMIN" b2="138 KV" b3="T15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6730</SeqNum>
    <Name>L230.NewFreedom-Cardiff.2310</Name>
    <LastEdit Timestamp="2026-02-13T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="V CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="W CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="1-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="2-14" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARDIFF" b2="230 KV" b3="CAR-NEW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6740</SeqNum>
    <Name>L138.DoremusPlace-Newark.N-1366</Name>
    <LastEdit Timestamp="2025-08-26T17:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="DOREMUSP" b2="138 KV" b3="DOREMUSP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DOREMUSP" b2="138 KV" b3="FOODBKSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOREMUSP" b2="138 KV" b3="SECT 2-3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOREMUSP" b2="138 KV" b3="T-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOREMUSP" b2="138 KV" b3="T-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="3-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOREMUSP" b2="138 KV" b3="DOR-NEW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6750</SeqNum>
    <Name>L230.NorthBergen-49thStreet-Hoboken.R-2270</Name>
    <LastEdit Timestamp="2025-11-17T08:37:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="49STREET" b2="230 KV" b3="49T-HOBR" />
      <ContingencyEquipment Action="L" Type="LN" b1="49STREET" b2="230 KV" b3="49T-NBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOBOKEN" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOBOKEN" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBERGEN" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBERGEN" b2="230 KV" b3="T-30" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NBERGEN" b2="230 KV" b3="T30" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6760</SeqNum>
    <Name>L230.Newton-Iliff-Montville.N2214</Name>
    <LastEdit Timestamp="2025-02-18T15:20:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ILIFF" b2="230 KV" b3="230LOAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ILIFF" b2="230 KV" b3="ILI-MONT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTVILL" b2="230 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTVILL" b2="230 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTON" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="ILIFF" b2="230 KV" b3="ILI-NEWT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6770</SeqNum>
    <Name>L230.MartinsCreek-Northwood.1011</Name>
    <LastEdit Timestamp="2024-11-06T12:15:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="NORT_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="NORT_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="230 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="230 KV" b3="B27" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARTINSC" b2="230 KV" b3="MAR-NOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6780</SeqNum>
    <Name>L230.Northwood-Quarry</Name>
    <LastEdit Timestamp="2024-12-05T16:00:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="230 KV" b3="B28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="230 KV" b3="B29" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHWOO" b2="230 KV" b3="NOR-QUA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="230 KV" b3="NORT_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="230 KV" b3="NORT_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6790</SeqNum>
    <Name>L230.Cooper-PeachBottomTap-Nottingham.220-08</Name>
    <LastEdit Timestamp="2025-08-26T17:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOPERPE" b2="230 KV" b3="125" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOPERPE" b2="230 KV" b3="COO-PEA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COOPERPE" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTTINGH" b2="230 KV" b3="085" />
      <ContingencyEquipment Action="S" Type="SD" b1="NOTTINGH" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="S" Type="SD" b1="NOTTINGH" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="NOTTINGH" b2="230 KV" b3="NOT-PEA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEACHTAP" b2="13 KV" b3="2SU" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEACHTAP" b2="230 KV" b3="2SU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6800</SeqNum>
    <Name>L115.Northwest-Delight-Gwynbrook-MaysChapel.110578</Name>
    <LastEdit Timestamp="2025-04-21T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="DELIGHT" b2="115 KV" b3="1XF_2XF" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELIGHT" b2="115 KV" b3="DEL-GWY8" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELIGHT" b2="115 KV" b3="DEL-NOR8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELIGHT" b2="115 KV" b3="XF1_578" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOLFIELD" b2="115 KV" b3="DOL-GWY6" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOLFIELD" b2="115 KV" b3="DOL-SUD6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GWYNNBRO" b2="115 KV" b3="110576" />
      <ContingencyEquipment Action="L" Type="LN" b1="GWYNNBRO" b2="115 KV" b3="GWY-MAY8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYSCHAP" b2="115 KV" b3="110578-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="110578-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="110578-5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUDBROOK" b2="115 KV" b3="13TR_576" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUDBROOK" b2="115 KV" b3="24TR_576" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUDBROOK" b2="115 KV" b3="24TR_577" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6810</SeqNum>
    <Name>L115.WindyEdge-Chesc-E.Pnt-G.Mnr-RiverSide.110501</Name>
    <LastEdit Timestamp="2025-04-24T14:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHESACO" b2="115 KV" b3="CHE-EAP" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESACO" b2="115 KV" b3="CHE-WIN" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTPT" b2="115 KV" b3="EAP-GRA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYMANO" b2="115 KV" b3="GRA-RIV1" />
      <ContingencyEquipment Action="S" Type="SD" b1="RIVERSID" b2="115 KV" b3="110501SD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="115 KV" b3="1TR_501" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110501" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6820</SeqNum>
    <Name>L115.WindyEdge-Fullrtn-Chesc-GMnr-Riverside.110502</Name>
    <LastEdit Timestamp="2025-11-17T16:07:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESACO" b2="115 KV" b3="110580CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESACO" b2="115 KV" b3="CHE-FUL" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESACO" b2="115 KV" b3="CHE-GRA" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESACO" b2="115 KV" b3="CHE-MID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULLERTO" b2="115 KV" b3="1TR_502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULLERTO" b2="115 KV" b3="2TR502HS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="FULLERTO" b2="115 KV" b3="2TR503HS" />
      <ContingencyEquipment Action="L" Type="LN" b1="FULLERTO" b2="115 KV" b3="FUL-WIN2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GRAYMANO" b2="115 KV" b3="1TR_502" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GRAYMANO" b2="115 KV" b3="2TR_502" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYMANO" b2="115 KV" b3="GRA-RIV2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MIDDLERI" b2="115 KV" b3="5TR_02" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MIDDLERI" b2="115 KV" b3="6TR_02" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MIDDLERI" b2="115 KV" b3="6TR_83" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MIDDLERI" b2="115 KV" b3="7TR_02" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MIDDLERI" b2="115 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="S" Type="SD" b1="RIVERSID" b2="115 KV" b3="110502SD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="115 KV" b3="2TR_502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110502" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6840</SeqNum>
    <Name>L115.WindyEdg-GoldRng-EPt-GrayMnr-RiverSid.110504</Name>
    <LastEdit Timestamp="2026-02-27T15:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="EASTPT" b2="115 KV" b3="110-2HS" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTPT" b2="115 KV" b3="EAP-GOL4" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTPT" b2="115 KV" b3="EAP-GRA4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOLDENRI" b2="115 KV" b3="1TR504HS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GOLDENRI" b2="115 KV" b3="2TR504HS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="GOLDENRI" b2="13 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOLDENRI" b2="115 KV" b3="GOL-WIN" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="GRAYMANO" b2="115 KV" b3="2TR_502" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GRAYMANO" b2="115 KV" b3="2TR_504" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYMANO" b2="115 KV" b3="GRA-RIV4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="115 KV" b3="110504" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110504" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6850</SeqNum>
    <Name>L115.Northwest-Delight-Gwynbrook-MaysChapel.110579</Name>
    <LastEdit Timestamp="2025-04-24T14:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="DELIGHT" b2="115 KV" b3="1XF_2XF" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELIGHT" b2="115 KV" b3="DEL-GWY9" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELIGHT" b2="115 KV" b3="DEL-NOR9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELIGHT" b2="115 KV" b3="XF2_579" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOLFIELD" b2="115 KV" b3="DOL-GWY7" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOLFIELD" b2="115 KV" b3="DOL-SUD7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GWYNNBRO" b2="115 KV" b3="110577" />
      <ContingencyEquipment Action="L" Type="LN" b1="GWYNNBRO" b2="115 KV" b3="GWY-MAY9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYSCHAP" b2="115 KV" b3="110579-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="110579" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="579-561" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUDBROOK" b2="115 KV" b3="13TR_576" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUDBROOK" b2="115 KV" b3="13TR_577" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUDBROOK" b2="115 KV" b3="24TR_577" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6860</SeqNum>
    <Name>L230.Conastone-Northwest.2310</Name>
    <LastEdit Timestamp="2025-08-26T17:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="2310CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="2310_02" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="2371-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="5TR-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONASTON" b2="230 KV" b3="CNS-NOR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6870</SeqNum>
    <Name>L230.Conastone-Northwest.2322</Name>
    <LastEdit Timestamp="2025-08-26T17:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="1TR_2322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="2322 GCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONASTON" b2="230 KV" b3="CNS-NOR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="2370-22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="4TR-22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6880</SeqNum>
    <Name>230/115.Northwest.230-3</Name>
    <LastEdit Timestamp="2025-02-25T19:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NORTHWES" b2="230 KV" b3="230-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWES" b2="115 KV" b3="230-3LS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWES" b2="230 KV" b3="2371CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NORTHWES" b2="230 KV" b3="CAP3" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHWES" b2="230 KV" b3="NOR-NOR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6890</SeqNum>
    <Name>230/115.Northwest.230-2</Name>
    <LastEdit Timestamp="2025-06-04T13:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NORTHWES" b2="230 KV" b3="230-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWES" b2="115 KV" b3="230-2LS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWES" b2="230 KV" b3="2370CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NORTHWES" b2="230 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWES" b2="230 KV" b3="CAP2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6900</SeqNum>
    <Name>L115.ESayreville-NWaverly-SOwego-Chemung-Hillside</Name>
    <LastEdit Timestamp="2026-02-12T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMUNG" b2="115 KV" b3="1B-44" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHEMUNG" b2="115 KV" b3="CHE-HIL2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHEMUNG" b2="115 KV" b3="TB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSIDE" b2="115 KV" b3="96212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWAVERLY" b2="115 KV" b3="CB 01" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHEMUNG" b2="115 KV" b3="CHE-NWA" />
      <ContingencyEquipment Action="L" Type="LN" b1="ESAYRE" b2="115 KV" b3="ESA-NWA" />
      <ContingencyEquipment Action="L" Type="LN" b1="NWAVERLY" b2="115 KV" b3="NWAV-SOW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOWEGO" b2="115 KV" b3="96272" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6910</SeqNum>
    <Name>L230.Burtonsville-OakGrove.23042</Name>
    <LastEdit Timestamp="2026-02-13T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="23042B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="13AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="13BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURTONSV" b2="230 KV" b3="BUR-OAK2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6920</SeqNum>
    <Name>L230.Burtonsville-OakGrove.23045</Name>
    <LastEdit Timestamp="2026-02-13T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="23045B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="9AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="9BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURTONSV" b2="230 KV" b3="BUR-OAK5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6930</SeqNum>
    <Name>L230.ChalkPt-Aquasco-OakGrv-HollndClf.23062/23152</Name>
    <LastEdit Timestamp="2026-03-31T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUASCO" b2="230 KV" b3="1120" />
      <ContingencyEquipment Action="L" Type="LN" b1="AQUASCO" b2="230 KV" b3="AQU-CHA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="AQUASCO" b2="230 KV" b3="AQU-OAK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="6AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="6BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="14BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="14CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6940</SeqNum>
    <Name>L230.ChalkPoint-OakGrove.23064</Name>
    <LastEdit Timestamp="2026-02-13T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="5AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="5BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="13BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="13CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHALKPT" b2="230 KV" b3="CHA-OAK4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6950</SeqNum>
    <Name>L230.Morgantown-Hawkins-OakGrove.23077/87</Name>
    <LastEdit Timestamp="2026-02-13T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HAWKINS" b2="230 KV" b3="HAW-HAW1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAWKINS" b2="230 KV" b3="HAW-MOR7" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAWKINS" b2="230 KV" b3="HAW-OAK7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAWKINSM" b2="230 KV" b3="1020" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="5BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="5CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="6BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="6CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6960</SeqNum>
    <Name>L230.BurchesHill-PalmersCorner.23091</Name>
    <LastEdit Timestamp="2026-02-13T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="2AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="2BB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PALMERS" b2="230 KV" b3="084-2T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="230 KV" b3="23106B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="69 KV" b3="2TS2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="69 KV" b3="2TS3B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURCHESH" b2="230 KV" b3="BUR-PAL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6970</SeqNum>
    <Name>L230.PalmersCorner-BluePlains-Potomac.23106</Name>
    <LastEdit Timestamp="2026-02-17T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="BLUEPLAI" b2="230 KV" b3="083-6R" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEPLAI" b2="230 KV" b3="BLU-PAL6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEPLAI" b2="230 KV" b3="BLU-POT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEPLAI" b2="230 KV" b3="LINK6B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEPLAI" b2="230 KV" b3="LINK6WB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="230 KV" b3="23106B" />
      <ContingencyEquipment Action="P" Type="XF" b1="POTOMAC" b2="69 KV" b3="8T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="8TSB" />
      <ContingencyEquipment Action="X" Type="XF" b1="POTOMAC" b2="230 KV" b3="STAC-8T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6980</SeqNum>
    <Name>L230.PalmersCorner-PotomacRiver.23108</Name>
    <LastEdit Timestamp="2024-09-10T13:32:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="PALMERS" b2="230 KV" b3="1085R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="230 KV" b3="23108B" />
      <ContingencyEquipment Action="L" Type="LN" b1="PALMERS" b2="230 KV" b3="PAL-POT1" />
      <ContingencyEquipment Action="P" Type="XF" b1="POTOMAC" b2="69 KV" b3="9T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="9TSB" />
      <ContingencyEquipment Action="X" Type="XF" b1="POTOMAC" b2="230 KV" b3="STAC-9T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>6990</SeqNum>
    <Name>L230.BurchesHill-PalmersCorner.23092</Name>
    <LastEdit Timestamp="2026-02-13T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="3AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="3BB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PALMERS" b2="230 KV" b3="084-3T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="230 KV" b3="23107B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="69 KV" b3="3TS3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="69 KV" b3="3TS4B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURCHESH" b2="230 KV" b3="BUR-PAL2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7000</SeqNum>
    <Name>L230.PalmersCorner-BluePlains-Potomac.23107</Name>
    <LastEdit Timestamp="2026-02-17T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="BLUEPLAI" b2="230 KV" b3="083-7R" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEPLAI" b2="230 KV" b3="BLU-PAL7" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEPLAI" b2="230 KV" b3="BLU-POT3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEPLAI" b2="230 KV" b3="LINK7B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEPLAI" b2="230 KV" b3="LINK7RB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="230 KV" b3="23107B" />
      <ContingencyEquipment Action="P" Type="XF" b1="POTOMAC" b2="69 KV" b3="7T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="230 KV" b3="7TPL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="7TSB" />
      <ContingencyEquipment Action="X" Type="XF" b1="POTOMAC" b2="230 KV" b3="STAC-7T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7010</SeqNum>
    <Name>L230.BurchesHill-PalmersCorner.23090</Name>
    <LastEdit Timestamp="2025-11-02T06:14:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="4AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="4BB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PALMERS" b2="230 KV" b3="084-4T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="230 KV" b3="23088B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="230 KV" b3="23109B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="69 KV" b3="4TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="69 KV" b3="4TS4B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURCHESH" b2="230 KV" b3="BUR-PAL0" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7020</SeqNum>
    <Name>L230.GraysFerry-Tunnel.220-89 + 230/13.GrysFrry.T1</Name>
    <LastEdit Timestamp="2026-02-13T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="GRAYSFER" b2="230 KV" b3="1TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="13 KV" b3="1TRLS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="275 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="295 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNNEL" b2="230 KV" b3="125 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNNEL" b2="230 KV" b3="225 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYSFER" b2="230 KV" b3="GRA-TUN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TUNNEL" b2="230 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7030</SeqNum>
    <Name>L230.GraysFerry-Passyunk.220-11+L69.Pas-SWark.6637</Name>
    <LastEdit Timestamp="2025-01-21T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="115 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PASSYUNK" b2="69 KV" b3="435 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYSFER" b2="230 KV" b3="GRA-PAS" />
      <ContingencyEquipment Action="X" Type="XF" b1="PASSYUNK" b2="230 KV" b3="PAS 9TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="PASSYUNK" b2="69 KV" b3="PAS-SWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWARK" b2="69 KV" b3="35 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWARK" b2="69 KV" b3="375 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SWARK" b2="69 KV" b3="SWK 3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7040</SeqNum>
    <Name>L230.Newlinville-Cochranville-PeachBottom.220-34</Name>
    <LastEdit Timestamp="2025-11-18T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COCHRNVL" b2="230 KV" b3="1TR" />
      <ContingencyEquipment Action="S" Type="SD" b1="COCHRNVL" b2="230 KV" b3="22034SD" />
      <ContingencyEquipment Action="L" Type="LN" b1="COCHRNVL" b2="230 KV" b3="COC-NEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLINVI" b2="230 KV" b3="260  CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLINVI" b2="230 KV" b3="270 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEACHBOT" b2="13 KV" b3="343SU" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEACHBOT" b2="230 KV" b3="343SU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="230 KV" b3="345 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="COCHRNVL" b2="230 KV" b3="COC-PEA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7050</SeqNum>
    <Name>230/69.Copperstone.T1</Name>
    <LastEdit Timestamp="2025-01-17T15:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="COPPERST" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="69 KV" b3="T1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="230 KV" b3="TRAN1CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7060</SeqNum>
    <Name>L230.Bridgeport-Pedricktown.2311</Name>
    <LastEdit Timestamp="2026-02-13T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEPO" b2="230 KV" b3="BUSGCBA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEPO" b2="230 KV" b3="BUSGCBC" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIDGEPO" b2="230 KV" b3="BRI-PED" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEDRICKT" b2="230 KV" b3="BUSGCBA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEDRICKT" b2="230 KV" b3="BUSGCBC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7070</SeqNum>
    <Name>L115.Portland-PequestRiver.Q927</Name>
    <LastEdit Timestamp="2025-08-14T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEQUESTR" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEQUESTR" b2="115 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="PEQUESTR" b2="115 KV" b3="PEQ-POR" />
      <ContingencyEquipment Action="S" Type="SD" b1="PEQUESTR" b2="115 KV" b3="REACTOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTLAND" b2="115 KV" b3="B92712" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7080</SeqNum>
    <Name>L230.RaphaelRoad-OtterPoint-Perryman.2360</Name>
    <LastEdit Timestamp="2025-06-05T08:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="OTTERPT" b2="230 KV" b3="1_2TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTERPT" b2="230 KV" b3="2360 OCB" />
      <ContingencyEquipment Action="S" Type="SD" b1="OTTERPT" b2="230 KV" b3="2360SD" />
      <ContingencyEquipment Action="L" Type="LN" b1="OTTERPT" b2="230 KV" b3="OTT-PER0" />
      <ContingencyEquipment Action="L" Type="LN" b1="OTTERPT" b2="230 KV" b3="OTT-RAP0" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PERRYMAN" b2="230 KV" b3="230-1GCB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PERRYMAN" b2="230 KV" b3="230-1_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPHAERD" b2="230 KV" b3="2360_1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPHAERD" b2="230 KV" b3="2360_2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7090</SeqNum>
    <Name>L230.RaphaelRoad-OtterPoint-Perryman.2361</Name>
    <LastEdit Timestamp="2026-02-17T11:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="OTTERPT" b2="230 KV" b3="1_2TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTERPT" b2="230 KV" b3="2361 OCB" />
      <ContingencyEquipment Action="S" Type="SD" b1="OTTERPT" b2="230 KV" b3="2361SD" />
      <ContingencyEquipment Action="L" Type="LN" b1="OTTERPT" b2="230 KV" b3="OTT-PER1" />
      <ContingencyEquipment Action="L" Type="LN" b1="OTTERPT" b2="230 KV" b3="OTT-RAP1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PERRYMAN" b2="230 KV" b3="230-1_2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PERRYMAN" b2="230 KV" b3="230-2GCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPHAERD" b2="230 KV" b3="2361_1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPHAERD" b2="230 KV" b3="2361_2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7120</SeqNum>
    <Name>L69.Monroe-PineHill.0752</Name>
    <LastEdit Timestamp="2026-02-17T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="69 KV" b3="GCB E" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONR AE" b2="69 KV" b3="MON-PIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEHILL" b2="69 KV" b3="OCB C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7140</SeqNum>
    <Name>L69.Monroe-WinslowT-Winslow-Williams.0755</Name>
    <LastEdit Timestamp="2026-02-20T11:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="69 KV" b3="GCB D" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONR AE" b2="69 KV" b3="MON-WIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLIAMS" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="WILLIAMS" b2="69 KV" b3="WIL-WIN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WINSLOW" b2="69 KV" b3="M" />
      <ContingencyEquipment Action="L" Type="LN" b1="WINSLOW" b2="69 KV" b3="WIN-WINT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7160</SeqNum>
    <Name>L69.Lindenwold-SilverLake.0744</Name>
    <LastEdit Timestamp="2026-02-17T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LINDENWO" b2="69 KV" b3="LIN-SIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDENWO" b2="69 KV" b3="OCB B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERLA" b2="69 KV" b3="OCB D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7170</SeqNum>
    <Name>L230.Bradford-Planebrook.220-02</Name>
    <LastEdit Timestamp="2024-10-23T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="230 KV" b3="220 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="25CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADFORD" b2="230 KV" b3="BRA-PLA2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7180</SeqNum>
    <Name>L230.Nottingham-Daleville-Bradford.220-05</Name>
    <LastEdit Timestamp="2025-11-18T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="230 KV" b3="250 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADFORD" b2="230 KV" b3="BRA-DAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DALESVIL" b2="230 KV" b3="1TR" />
      <ContingencyEquipment Action="S" Type="SD" b1="DALESVIL" b2="230 KV" b3="220-05" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DALESVIL" b2="230 KV" b3="2TR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DALESVIL" b2="230 KV" b3="CHESTER" />
      <ContingencyEquipment Action="L" Type="LN" b1="DALESVIL" b2="230 KV" b3="DAL-NOT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTTINGH" b2="230 KV" b3="055" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7200</SeqNum>
    <Name>L230.Whitpain-PlymouthMeeting.220-13</Name>
    <LastEdit Timestamp="2025-12-19T10:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="230 KV" b3="315" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLYMOUTH" b2="230 KV" b3="PLY-WHI3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="230 KV" b3="135 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7210</SeqNum>
    <Name>L230.Whitpain-PlymouthMeeting.220-15</Name>
    <LastEdit Timestamp="2026-02-17T11:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="230 KV" b3="155 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLYMOUTH" b2="230 KV" b3="PLY-WHI5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="230 KV" b3="155 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7220</SeqNum>
    <Name>L230.Whitpain-PlymouthMeeting.220-14</Name>
    <LastEdit Timestamp="2025-12-23T07:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="230 KV" b3="435" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLYMOUTH" b2="230 KV" b3="PLY-WHI4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="230 KV" b3="145 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7250</SeqNum>
    <Name>L115.Chestnut-Frederick-ViaductAve-Pumphrey.110528</Name>
    <LastEdit Timestamp="2025-12-04T17:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTNUT" b2="115 KV" b3="110528" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTNUT" b2="115 KV" b3="CHE-FRE8" />
      <ContingencyEquipment Action="CL" Type="CB" b1="FRED BC" b2="115 KV" b3="1_4TR27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRED BC" b2="115 KV" b3="1_4TR28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRED BC" b2="115 KV" b3="2_3TR28" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRED BC" b2="115 KV" b3="FRE-VIA8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="110528" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="528_520" />
      <ContingencyEquipment Action="L" Type="LN" b1="PUMPHREY" b2="115 KV" b3="PUM-VIA8" />
      <ContingencyEquipment Action="CL" Type="CB" b1="VIADUCAV" b2="115 KV" b3="527_1XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIADUCAV" b2="115 KV" b3="528_1XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7260</SeqNum>
    <Name>Croydon.CTs</Name>
    <LastEdit Timestamp="2025-01-21T12:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="11 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="12 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="230 KV" b3="135 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="21 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="22 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="230 KV" b3="235 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="31 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="32 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="41 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="42 CT CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROYDON" b2="230 KV" b3="CROY 10" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROYDON" b2="230 KV" b3="CROY 20" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROYDON" b2="230 KV" b3="CROY 30" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROYDON" b2="230 KV" b3="CROY 40" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT21" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT22" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT31" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT32" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT41" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT42" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7270</SeqNum>
    <Name>L345.Ladentown-Ramapo</Name>
    <LastEdit Timestamp="2024-12-03T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LADENTOW" b2="345 KV" b3="1-56-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADENTOW" b2="345 KV" b3="4-56-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LADENTOW" b2="345 KV" b3="LAD-RAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="T1500-72" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="W-72-2Y" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7290</SeqNum>
    <Name>L230.Northeast-RaphaelRoad.2337</Name>
    <LastEdit Timestamp="2026-02-17T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="230 KV" b3="2337CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPHAERD" b2="230 KV" b3="2313_37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPHAERD" b2="230 KV" b3="2337" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHEAS" b2="230 KV" b3="NOR-RAP7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7300</SeqNum>
    <Name>L230.Lewistown-Raystown.2027</Name>
    <LastEdit Timestamp="2024-12-30T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B88" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAYSTOWN" b2="230 KV" b3="B29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAYSTOWN" b2="230 KV" b3="B33" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEWISTOW" b2="230 KV" b3="LEW-RAY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7310</SeqNum>
    <Name>L230.Branchburg-Readington.M-2265</Name>
    <LastEdit Timestamp="2025-12-03T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="11-13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT2-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="READINGT" b2="230 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="READINGT" b2="35 KV" b3="BK 1LCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="READINGT" b2="230 KV" b3="BK 1TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANCHBU" b2="230 KV" b3="BRA-REA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7320</SeqNum>
    <Name>L230.Readington-Roseland.U-2221</Name>
    <LastEdit Timestamp="2025-12-03T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="READINGT" b2="230 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="READINGT" b2="35 KV" b3="BK 2LCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="READINGT" b2="230 KV" b3="BK 2TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="READINGT" b2="230 KV" b3="REA-ROS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="8-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="8-15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7330</SeqNum>
    <Name>L230.RedLion-SilverRun.2</Name>
    <LastEdit Timestamp="2025-04-08T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDLION" b2="230 KV" b3="RED-SIL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERUN" b2="230 KV" b3="F120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERUN" b2="230 KV" b3="F130" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7340</SeqNum>
    <Name>230/138.RedLion.AT20</Name>
    <LastEdit Timestamp="2026-02-13T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDLION" b2="230 KV" b3="20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="231" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7350</SeqNum>
    <Name>L230.Camden-Richmond.C-220-29</Name>
    <LastEdit Timestamp="2026-03-26T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDEN" b2="230 KV" b3="13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDEN" b2="230 KV" b3="2-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="230 KV" b3="415 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="230 KV" b3="475 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RICH PE" b2="230 KV" b3="4TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMDEN" b2="230 KV" b3="CAM-RIC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7360</SeqNum>
    <Name>L115.WindyEdge-Fullrtn-GldRng-EPnt-Riversid.110503</Name>
    <LastEdit Timestamp="2025-04-28T15:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EASTPT" b2="115 KV" b3="110-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTPT" b2="115 KV" b3="EAP-RIV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULLERTO" b2="115 KV" b3="1TR503HS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="FULLERTO" b2="115 KV" b3="1TR_502" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FULLERTO" b2="115 KV" b3="DUMWIN3" />
      <ContingencyEquipment Action="L" Type="LN" b1="FULLERTO" b2="115 KV" b3="FUL-GOL" />
      <ContingencyEquipment Action="L" Type="LN" b1="FULLERTO" b2="115 KV" b3="FUL-WIN3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="GOLDENRI" b2="115 KV" b3="2TR503HS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GOLDENRI" b2="115 KV" b3="2TR504HS" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTPT" b2="115 KV" b3="EAP-GOL3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="115 KV" b3="110503" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110503" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7380</SeqNum>
    <Name>L230.Northeast-Riverside.2317</Name>
    <LastEdit Timestamp="2026-02-17T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="230 KV" b3="2317CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHEAS" b2="230 KV" b3="NOR-RIV7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="230 KV" b3="2317OCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7390</SeqNum>
    <Name>L345.Ramapo-RockTavern</Name>
    <LastEdit Timestamp="2026-02-20T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="77-2X" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="T77-94-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKTAVE" b2="345 KV" b3="377545" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKTAVE" b2="345 KV" b3="377556" />
      <ContingencyEquipment Action="L" Type="LN" b1="RAMAPO" b2="345 KV" b3="RAM-ROC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7400</SeqNum>
    <Name>L138.Emilie-Rolling.130-39</Name>
    <LastEdit Timestamp="2026-02-19T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="138 KV" b3="190 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROLL PE" b2="138 KV" b3="120 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EMILIE" b2="138 KV" b3="EMI-ROL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7410</SeqNum>
    <Name>L138.Biles-SteelTap-RollingMill</Name>
    <LastEdit Timestamp="2026-02-19T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BILES" b2="138 KV" b3="10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROLL PE" b2="138 KV" b3="130 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROLL PE" b2="138 KV" b3="ROL-STE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELTAP" b2="138 KV" b3="60" />
      <ContingencyEquipment Action="L" Type="LN" b1="BILES" b2="138 KV" b3="BIL-STE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7420</SeqNum>
    <Name>L230.Montville-Roseland.E-2205</Name>
    <LastEdit Timestamp="2026-04-24T08:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTVILL" b2="230 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTVILL" b2="230 KV" b3="B33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="2-13" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONTVILL" b2="230 KV" b3="MNT-ROS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7450</SeqNum>
    <Name>L345.RockTavern-Roseton</Name>
    <LastEdit Timestamp="2026-02-19T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKTAVE" b2="345 KV" b3="31153" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKTAVE" b2="345 KV" b3="31154" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSETON" b2="345 KV" b3="31151" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSETON" b2="345 KV" b3="31152" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKTAVE" b2="345 KV" b3="ROC-ROS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7470</SeqNum>
    <Name>L230.Millwood-SouthAkron + Millwood.T1 + SAkron.T3</Name>
    <LastEdit Timestamp="2025-10-17T17:49:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLWDPL" b2="230 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLWDPL" b2="230 KV" b3="MIL-SAK" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILLWDPL" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLWDPL" b2="69 KV" b3="T1 LS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SAKRON" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="MLWD_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="MLWD_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="69 KV" b3="TRAN_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7480</SeqNum>
    <Name>L230.SManheim-SAkron + 230/69.SMan.T4&amp;SAkron.T4</Name>
    <LastEdit Timestamp="2026-02-17T11:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SAKRON" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="SMAN_4-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="SMAN_4-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="69 KV" b3="TRAN_4" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMANHEIM" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMANHEIM" b2="230 KV" b3="LINE_MOD" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAKRON" b2="230 KV" b3="SAK-SMA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMANHEIM" b2="69 KV" b3="TRAN_4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7490</SeqNum>
    <Name>L230.MiddletownJct-SouthLebanon.1004</Name>
    <LastEdit Timestamp="2025-12-09T16:28:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B100442" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B100482" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLEBANON" b2="230 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLEBANON" b2="230 KV" b3="B80" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDDLJCT" b2="230 KV" b3="MID-SLE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7500</SeqNum>
    <Name>L230.Berks-SouthLebanon.1074</Name>
    <LastEdit Timestamp="2025-11-05T09:13:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKS" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKS" b2="230 KV" b3="3-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERKS" b2="230 KV" b3="BER-SLE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKS" b2="230 KV" b3="TRAN3HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLEBANON" b2="230 KV" b3="B70" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLEBANON" b2="230 KV" b3="B80" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7510</SeqNum>
    <Name>L230.Cedar-OysterCreek</Name>
    <LastEdit Timestamp="2025-04-01T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="230 KV" b3="GCB LL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="230 KV" b3="GCB NN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OYSTERCR" b2="230 KV" b3="B104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OYSTERCR" b2="230 KV" b3="B94" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDAR" b2="230 KV" b3="CED-OYS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7520</SeqNum>
    <Name>L230.Chichester-Saville.130-50</Name>
    <LastEdit Timestamp="2026-03-12T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="138 KV" b3="505 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAVILLE" b2="138 KV" b3="905 CB" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SAVILLE" b2="138 KV" b3="9BUS" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICHEST" b2="138 KV" b3="CHI-SAV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7530</SeqNum>
    <Name>L138.Eddystone-Saville.130-40</Name>
    <LastEdit Timestamp="2026-03-12T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="138 KV" b3="275" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="EDDYSTON" b2="138 KV" b3="70XFMR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAVILLE" b2="138 KV" b3="705 CB" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SAVILLE" b2="138 KV" b3="7BUS" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDDYSTON" b2="138 KV" b3="EDD-SAV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7540</SeqNum>
    <Name>L230.Sayreville-RedOakB-Parlin.G1047</Name>
    <LastEdit Timestamp="2025-12-11T09:37:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PARLIN" b2="230 KV" b3="GA GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARLIN" b2="230 KV" b3="GB GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDOAKB" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDOAKB" b2="18 KV" b3="CT" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDOAKB" b2="230 KV" b3="CT TRAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="PARLIN" b2="230 KV" b3="PAR-REDB" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDOAKB" b2="230 KV" b3="REDB-SAY" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDOAKB" b2="18 KV" b3="ST" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDOAKB" b2="230 KV" b3="ST TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="B143" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="B144" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7560</SeqNum>
    <Name>L230.Shawnee-Foxhill + Shawnee.T1</Name>
    <LastEdit Timestamp="2025-12-31T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOXHILL" b2="230 KV" b3="B16" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWNEE" b2="230 KV" b3="1 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEE" b2="34 KV" b3="1B32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEE" b2="230 KV" b3="B7" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOXHILL" b2="230 KV" b3="FOX-SHA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7580</SeqNum>
    <Name>L230.Lewistown-Shingletown.2023</Name>
    <LastEdit Timestamp="2025-04-25T17:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B57" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B90" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHINGLET" b2="230 KV" b3="B57" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEWISTOW" b2="230 KV" b3="LEW-SHI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7590</SeqNum>
    <Name>L230.Shawville-Shingletown.2022</Name>
    <LastEdit Timestamp="2025-05-27T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWVILL" b2="230 KV" b3="B87" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHINGLET" b2="230 KV" b3="B7" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHAWVILL" b2="230 KV" b3="SHA-SHI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7600</SeqNum>
    <Name>L230.NewFreedom-Sickler.2308</Name>
    <LastEdit Timestamp="2025-09-08T09:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="230 2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="230 5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SICKLER" b2="230 KV" b3="AW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SICKLER" b2="230 KV" b3="BV" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWFREED" b2="230 KV" b3="NEW-SIC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7610</SeqNum>
    <Name>L230.Frackville-Siegfried</Name>
    <LastEdit Timestamp="2025-03-24T12:29:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="230 KV" b3="SIEG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="230 KV" b3="TR1_SIEG" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRACKVIL" b2="230 KV" b3="FRA-SIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="FRAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="FRACKTR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7620</SeqNum>
    <Name>L230.Levittown-MtLaurel-CoxsCorner.E-2231</Name>
    <LastEdit Timestamp="2025-04-10T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COXSCORN" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COXSCORN" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="COXSCORN" b2="230 KV" b3="COX-MTLE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEVITTOW" b2="230 KV" b3="1-2CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEVITTOW" b2="230 KV" b3="LEV-MTLE" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MTLAUREL" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MTLAUREL" b2="230 KV" b3="TRAN T-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7630</SeqNum>
    <Name>L230.Atlantic-NewProspectRoad-Smithburg</Name>
    <LastEdit Timestamp="2025-06-05T12:48:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ATLANTIC" b2="230 KV" b3="ATL-NEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B48" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPROSP" b2="230 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPROSP" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWPROSP" b2="230 KV" b3="BK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWPROSP" b2="230 KV" b3="NEW-SMI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWPROSP" b2="230 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHBUR" b2="230 KV" b3="BK2230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHBUR" b2="230 KV" b3="GA GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHBUR" b2="230 KV" b3="MG GC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7640</SeqNum>
    <Name>L230.Smithburg-Manalapan-Englishtown.M2039</Name>
    <LastEdit Timestamp="2025-10-30T15:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="230 KV" b3="B78" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="230 KV" b3="B84" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENGLISHT" b2="230 KV" b3="ENG-MAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MANALAPA" b2="230 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MANALAPA" b2="230 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANALAPA" b2="230 KV" b3="MAN-SMI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHBUR" b2="230 KV" b3="MB GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHBUR" b2="230 KV" b3="MG GC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7650</SeqNum>
    <Name>L230.Atlantic-SouthRiver.P1030</Name>
    <LastEdit Timestamp="2025-12-11T08:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ATLANTIC" b2="230 KV" b3="1TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="34 KV" b3="1TRDUM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B16" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATLANTIC" b2="230 KV" b3="ATL-SRI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SRIVER" b2="230 KV" b3="PA GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SRIVER" b2="230 KV" b3="PB GC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7660</SeqNum>
    <Name>L230.Sayreville-RedOakA-SouthRiver.T-1034</Name>
    <LastEdit Timestamp="2025-12-11T09:39:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="REDOAKA" b2="230 KV" b3="2TRAN" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDOAKA" b2="230 KV" b3="3TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDOAKA" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDOAKA" b2="18 KV" b3="CT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDOAKA" b2="18 KV" b3="CT3" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDOAKA" b2="230 KV" b3="REDA-SAY" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDOAKA" b2="230 KV" b3="REDA-SRI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="B145" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="B146" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SRIVER" b2="230 KV" b3="BT GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SRIVER" b2="230 KV" b3="TA GC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7670</SeqNum>
    <Name>L69.Lumberton-SouthHampton.B-600</Name>
    <LastEdit Timestamp="2026-02-20T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMBERTO" b2="69 KV" b3="1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMBERTO" b2="69 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="LUMBERTO" b2="69 KV" b3="LUM-SAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMPTON" b2="69 KV" b3="B600" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7680</SeqNum>
    <Name>L138.BlairsvilleEast-SocialHall + 138/115.BEast.T1</Name>
    <LastEdit Timestamp="2025-10-29T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAIRSVE" b2="115 KV" b3="B51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAIRSVE" b2="115 KV" b3="B55" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLAIRSVE" b2="138 KV" b3="BLA-SOC" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLAIRSVE" b2="138 KV" b3="NO.1 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOCIALHA" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7690</SeqNum>
    <Name>L230.Branchburg-Somerville.C-2203</Name>
    <LastEdit Timestamp="2026-02-13T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRANCHBU" b2="230 KV" b3="BRA-SOM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT5-6" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SOMERVIL" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOMERVIL" b2="230 KV" b3="SECT1-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SOMERVIL" b2="230 KV" b3="TRANT-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7700</SeqNum>
    <Name>L230.Jenkins-Mountain</Name>
    <LastEdit Timestamp="2024-10-23T08:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="230 KV" b3="MOUNEAST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="230 KV" b3="MOUNWEST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="230 KV" b3="23050" />
      <ContingencyEquipment Action="L" Type="LN" b1="JENKINS" b2="230 KV" b3="JEN-MOU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7710</SeqNum>
    <Name>L230.Mountain-Susquehanna</Name>
    <LastEdit Timestamp="2026-02-17T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="230 KV" b3="23040" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUN UGI" b2="230 KV" b3="MOU-SUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="MOUN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7720</SeqNum>
    <Name>230/69.Mountain.T3(UGI)</Name>
    <LastEdit Timestamp="2026-04-02T13:31:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="230 KV" b3="23040" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="230 KV" b3="23050" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOUN UGI" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66200" />
      <ContingencyEquipment Action="L" Type="LN" b1="JENKINS" b2="230 KV" b3="JEN-MOU" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUN UGI" b2="230 KV" b3="MOU-SUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7800</SeqNum>
    <Name>L230.Sunbury-Susquehanna</Name>
    <LastEdit Timestamp="2026-04-17T14:13:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="MIL1SUS1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUNBURY" b2="230 KV" b3="SUN-SUS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="SUSQ1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="SUNBHAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="SUNB_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7810</SeqNum>
    <Name>L230.Montour-Glenbrook.1</Name>
    <LastEdit Timestamp="2025-12-30T11:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GLENBROO" b2="230 KV" b3="GLE-MON1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="230 KV" b3="MONT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="230 KV" b3="MONTSUSQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="GEN1SUTI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="SUSQ_10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7820</SeqNum>
    <Name>L230.Harwood-Susquehanna.2</Name>
    <LastEdit Timestamp="2026-04-17T14:13:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HARWOOD" b2="230 KV" b3="HAR-SUS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="230 KV" b3="SUS2-EPA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="230 KV" b3="SUSQ2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="HARW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="SUNBHAR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7840</SeqNum>
    <Name>L230.Montour-Glenbrook.2</Name>
    <LastEdit Timestamp="2025-09-03T09:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GLENBROO" b2="230 KV" b3="GLE-MON2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="230 KV" b3="MONT2_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="230 KV" b3="MONT2_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="GEN2SUSQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="SUSQ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7850</SeqNum>
    <Name>L230.Hudson-SouthWaterFront.P-2268</Name>
    <LastEdit Timestamp="2024-09-26T16:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="3-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUDSON" b2="230 KV" b3="HUD-SWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="230 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="230 KV" b3="SECT 1-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7860</SeqNum>
    <Name>L230.Newport-Hoboken.T-2220</Name>
    <LastEdit Timestamp="2025-04-14T10:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOBOKEN" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOBOKEN" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOBOKEN" b2="230 KV" b3="HOB-NEWY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWP PS" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWP PS" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWP PS" b2="230 KV" b3="T-4LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7870</SeqNum>
    <Name>L230.Newport-SouthWaterfront.Q-2269</Name>
    <LastEdit Timestamp="2025-01-09T14:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWP PS" b2="230 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWP PS" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWP PS" b2="230 KV" b3="NEW-SWAQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="230 KV" b3="SECT 6-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="230 KV" b3="SECT 7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7880</SeqNum>
    <Name>L230.Jackson-TMI.1051</Name>
    <LastEdit Timestamp="2026-02-13T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="230 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="230 KV" b3="B9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="230 KV" b3="105102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="230 KV" b3="925102" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACK ME" b2="230 KV" b3="JAC-TMI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7890</SeqNum>
    <Name>230/115.Jackson.T4BA</Name>
    <LastEdit Timestamp="2024-12-02T12:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="JACK ME" b2="230 KV" b3="4 BA-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="JACK ME" b2="115 KV" b3="4 BA-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="230 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="115 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="230 KV" b3="B9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7900</SeqNum>
    <Name>L230.Jenkintown-Tabor.220-26</Name>
    <LastEdit Timestamp="2026-02-19T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINTO" b2="230 KV" b3="230 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TABOR" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TABOR" b2="230 KV" b3="905 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="JENKINTO" b2="230 KV" b3="JEN-TAB" />
      <ContingencyEquipment Action="X" Type="XF" b1="TABOR" b2="230 KV" b3="TR 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7910</SeqNum>
    <Name>L230.Waneeta-WayneJunction-Pulaski.220-42</Name>
    <LastEdit Timestamp="2025-11-18T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PULASKI" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PULASKI" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PULASKI" b2="13 KV" b3="LD 3TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="PULASKI" b2="230 KV" b3="PUL-WAY" />
      <ContingencyEquipment Action="X" Type="XF" b1="PULASKI" b2="230 KV" b3="PULS3TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="230 KV" b3="425 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="WANEETA" b2="230 KV" b3="WAN-WAY2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNEJCT" b2="230 KV" b3="1A CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="WAYNEJCT" b2="230 KV" b3="220-42" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7920</SeqNum>
    <Name>L69.Monroe-Tansboro.0754</Name>
    <LastEdit Timestamp="2025-04-10T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="69 KV" b3="GCB C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANSBORO" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANSBORO" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONR AE" b2="69 KV" b3="MON-TAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7930</SeqNum>
    <Name>L69.Sickler-ManvilleTap-Tansboro.0776</Name>
    <LastEdit Timestamp="2025-05-28T12:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MANVILTP" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANVILTP" b2="69 KV" b3="MAN-SICK" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANVILTP" b2="69 KV" b3="MAN-TANS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SICKLER" b2="69 KV" b3="OCB B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANSBORO" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANSBORO" b2="69 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7940</SeqNum>
    <Name>L230.Chichester-Trainer.220-53</Name>
    <LastEdit Timestamp="2026-02-17T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="230 KV" b3="535  CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="CHICHEST" b2="230 KV" b3="L22053" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRAINER" b2="230 KV" b3="1BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRAINER" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICHEST" b2="230 KV" b3="CHI-TRA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7950</SeqNum>
    <Name>L230.Gillette-SummitJC-Traynor.U-1035</Name>
    <LastEdit Timestamp="2026-02-17T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GILLETTE" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GILLETTE" b2="230 KV" b3="BK 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GILLETTE" b2="230 KV" b3="GIL-SUMU" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUMM JC" b2="230 KV" b3="SUM-TRAU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUMM JC" b2="230 KV" b3="TW TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRAYNOR" b2="230 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7960</SeqNum>
    <Name>L230.Gillette-SummitJC-Traynor.X-1038</Name>
    <LastEdit Timestamp="2025-04-25T17:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GILLETTE" b2="230 KV" b3="X1038 AB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GILLETTE" b2="230 KV" b3="GIL-SUMX" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUMM JC" b2="230 KV" b3="SUM-TRAX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUMM JC" b2="230 KV" b3="TE TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRAYNOR" b2="230 KV" b3="B60" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7970</SeqNum>
    <Name>L230.Planebrook-Tredyffrin-UppMerion-Flint.220-24</Name>
    <LastEdit Timestamp="2025-09-08T09:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINT" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINT" b2="230 KV" b3="705 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLINT" b2="230 KV" b3="FLI-UPP" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLINT" b2="230 KV" b3="FLNT2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="245 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TREDYFFR" b2="230 KV" b3="245" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TREDYFFR" b2="230 KV" b3="845 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLANEBRO" b2="230 KV" b3="PLA-TRE4" />
      <ContingencyEquipment Action="L" Type="LN" b1="TREDYFFR" b2="230 KV" b3="TRE-UPP4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERMER" b2="35 KV" b3="20 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="UPPERMER" b2="230 KV" b3="UP 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7980</SeqNum>
    <Name>L230.PlymouthMeeting-Flint.220-47</Name>
    <LastEdit Timestamp="2025-01-13T14:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINT" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINT" b2="230 KV" b3="705 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLINT" b2="230 KV" b3="FLI-PLY" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLINT" b2="230 KV" b3="FLNT3TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="230 KV" b3="475 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>7990</SeqNum>
    <Name>L230.Planebrook-TredyFfrin-UpperMerion.220-09</Name>
    <LastEdit Timestamp="2025-02-25T19:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="095" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TREDYFFR" b2="230 KV" b3="95 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLANEBRO" b2="230 KV" b3="PLA-TRE9" />
      <ContingencyEquipment Action="L" Type="LN" b1="TREDYFFR" b2="230 KV" b3="TRE-UPP9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERMER" b2="13 KV" b3="15 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERMER" b2="35 KV" b3="30 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERMER" b2="230 KV" b3="355 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="UPPERMER" b2="230 KV" b3="UP 11TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="UPPERMER" b2="230 KV" b3="UP 3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8000</SeqNum>
    <Name>L230.PlymouthMeeting-UpperMerion.220-69</Name>
    <LastEdit Timestamp="2026-02-19T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="230 KV" b3="695 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERMER" b2="13 KV" b3="25 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERMER" b2="230 KV" b3="355 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLYMOUTH" b2="230 KV" b3="PLY-UPP" />
      <ContingencyEquipment Action="X" Type="XF" b1="UPPERMER" b2="230 KV" b3="UP 12TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8010</SeqNum>
    <Name>L230.BrunnerIsland-WestHempfield+230/69.WH.T1</Name>
    <LastEdit Timestamp="2026-01-08T09:40:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNNERI" b2="230 KV" b3="T20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="WHEM" />
      <ContingencyEquipment Action="S" Type="SD" b1="BRUNNERI" b2="230 KV" b3="WHEMPFLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="WHEM_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="WHEM_W" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHEMPFIE" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="230 KV" b3="BRIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNNERI" b2="230 KV" b3="BRU-WHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8020</SeqNum>
    <Name>L230.Manor-WestHempfield + Manor.T4 + WHempf.T2&amp;T4</Name>
    <LastEdit Timestamp="2025-09-03T09:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MANOR" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANOR" b2="230 KV" b3="MAN-WHE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="TRAN4-CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="230 KV" b3="WHEM_2-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="230 KV" b3="WHEM_2-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHEMPFIE" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHEMPFIE" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="230 KV" b3="MANO_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="230 KV" b3="TRAN4HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8030</SeqNum>
    <Name>L230.Steelton-WestShore</Name>
    <LastEdit Timestamp="2025-04-15T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELTON" b2="230 KV" b3="TRAN_3SF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELTON" b2="230 KV" b3="WSHO" />
      <ContingencyEquipment Action="L" Type="LN" b1="STEELTON" b2="230 KV" b3="STE-WSH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHORE" b2="230 KV" b3="STEE_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHORE" b2="230 KV" b3="STEE_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8040</SeqNum>
    <Name>L115.Pumphrey-LipinsCorner-Wagner.110535</Name>
    <LastEdit Timestamp="2025-04-21T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIPINSCO" b2="115 KV" b3="1-4TR535" />
      <ContingencyEquipment Action="S" Type="SD" b1="LIPINSCO" b2="115 KV" b3="110535" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIPINSCO" b2="115 KV" b3="2-5TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIPINSCO" b2="115 KV" b3="2-5TR535" />
      <ContingencyEquipment Action="CL" Type="CB" b1="LIPINSCO" b2="115 KV" b3="3-6TR534" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIPINSCO" b2="115 KV" b3="3-6TR535" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIPINSCO" b2="115 KV" b3="LIP-PUM5" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIPINSCO" b2="115 KV" b3="LIP-WAG5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="110535" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="521_535" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="110535CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="535-2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8050</SeqNum>
    <Name>L115.Pumphrey-LipinsCorner-Wagner.110534</Name>
    <LastEdit Timestamp="2025-04-21T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIPINSCO" b2="115 KV" b3="1-4TR534" />
      <ContingencyEquipment Action="CL" Type="CB" b1="LIPINSCO" b2="115 KV" b3="1-4TR535" />
      <ContingencyEquipment Action="S" Type="SD" b1="LIPINSCO" b2="115 KV" b3="110534" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIPINSCO" b2="115 KV" b3="2-5TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIPINSCO" b2="115 KV" b3="2-5TR534" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIPINSCO" b2="115 KV" b3="3-6TR534" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIPINSCO" b2="115 KV" b3="LIP-PUM4" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIPINSCO" b2="115 KV" b3="LIP-WAG4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="110534" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="526_534" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAGNER" b2="115 KV" b3="110-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="34-1OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="34-1_403" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8060</SeqNum>
    <Name>L115.Pumphrey-Wagner.110532</Name>
    <LastEdit Timestamp="2026-02-19T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="110532" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="524_532" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAGNER" b2="115 KV" b3="110-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="32-3OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="32-3_402" />
      <ContingencyEquipment Action="L" Type="LN" b1="PUMPHREY" b2="115 KV" b3="PUM-WAG2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAGNER" b2="34 KV" b3="THRE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8070</SeqNum>
    <Name>L115.Pumphrey-Wagner.110533</Name>
    <LastEdit Timestamp="2026-02-17T10:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="110533" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="533_1TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="110533CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="533_401" />
      <ContingencyEquipment Action="L" Type="LN" b1="PUMPHREY" b2="115 KV" b3="PUM-WAG3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8080</SeqNum>
    <Name>345/230.Waldwick.345-1</Name>
    <LastEdit Timestamp="2026-02-17T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WALDWICK" b2="345 KV" b3="345-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="345 KV" b3="345SC1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="345 KV" b3="345SC2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="230 KV" b3="SECT1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="230 KV" b3="SECT3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8090</SeqNum>
    <Name>L230.WhiteHorse-KuserRoad-Trenton.H2208</Name>
    <LastEdit Timestamp="2025-08-13T14:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KUSERRD" b2="230 KV" b3="KUS-TRE" />
      <ContingencyEquipment Action="L" Type="LN" b1="KUSERRD" b2="230 KV" b3="KUS-WHIT" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KUSERRD" b2="230 KV" b3="T1-2TRAN" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KUSERRD" b2="230 KV" b3="T3-4TRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KUSERRD" b2="230 KV" b3="TRAN T-1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KUSERRD" b2="230 KV" b3="TRAN T-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITHRSE" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITHRSE" b2="230 KV" b3="2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8100</SeqNum>
    <Name>L230.Hillsdale-Waldwick</Name>
    <LastEdit Timestamp="2025-01-28T17:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="4-14" />
      <ContingencyEquipment Action="P" Type="XF" b1="WALDWICK" b2="230 KV" b3="2258PAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLSDAL" b2="230 KV" b3="HIL-WAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="230 KV" b3="SECT2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="230 KV" b3="SECT5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8110</SeqNum>
    <Name>L230.Richmond-Waneeta.220-35</Name>
    <LastEdit Timestamp="2026-02-19T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="230 KV" b3="525 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="230 KV" b3="575 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RICH PE" b2="230 KV" b3="6TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="230 KV" b3="355 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="RICH PE" b2="230 KV" b3="RIC-WAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8120</SeqNum>
    <Name>230/138.Waneeta.T8</Name>
    <LastEdit Timestamp="2026-02-19T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="230 KV" b3="85 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="138 KV" b3="885 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WANEETA" b2="230 KV" b3="WAN 8TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8130</SeqNum>
    <Name>L230.Buckingham-Warrington.220-19</Name>
    <LastEdit Timestamp="2026-02-19T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKINGH" b2="230 KV" b3="195 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINGT" b2="230 KV" b3="195 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKINGH" b2="230 KV" b3="BUC-WAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8150</SeqNum>
    <Name>L230.Hartman-Warrington</Name>
    <LastEdit Timestamp="2025-06-06T11:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARTMAN" b2="230 KV" b3="785" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINGT" b2="230 KV" b3="585 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARTMAN" b2="230 KV" b3="HAR-WAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8160</SeqNum>
    <Name>L345.ErieWest-Wayne.3004</Name>
    <LastEdit Timestamp="2024-10-23T09:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="345 KV" b3="B79" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="345 KV" b3="B82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE" b2="345 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE" b2="345 KV" b3="B32" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERIEW" b2="345 KV" b3="ERI-WAY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8170</SeqNum>
    <Name>L345.HandsomeLake-Wayne</Name>
    <LastEdit Timestamp="2024-08-01T08:35:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANDSOME" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANDSOME" b2="345 KV" b3="BWHL" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANDSOME" b2="345 KV" b3="HAN-WAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE" b2="345 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE" b2="345 KV" b3="B45" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8180</SeqNum>
    <Name>L345.HandsomeLake-Armstrong</Name>
    <LastEdit Timestamp="2024-08-01T08:32:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMSTRON" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMSTRON" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARMSTRON" b2="345 KV" b3="ARM-HAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANDSOME" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANDSOME" b2="345 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8230</SeqNum>
    <Name>138/69.Wescosville.T4</Name>
    <LastEdit Timestamp="2026-02-17T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WESCOSVI" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="138 KV" b3="TRAN_4HI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="69 KV" b3="TRAN_4LO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8240</SeqNum>
    <Name>500/230.WaughChapel.500-1</Name>
    <LastEdit Timestamp="2025-10-06T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="500 KV" b3="1TR_5051" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="230-1OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="230-2OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="230-3OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="23041BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="2327OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="23411BUS" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAUGHCHA" b2="500 KV" b3="500-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="500 KV" b3="500-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="500-31B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8250</SeqNum>
    <Name>L230.Buxmont-Whitpain+230/69.Buxmont.T1</Name>
    <LastEdit Timestamp="2024-09-23T10:57:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BUXMONT" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUXMONT" b2="69 KV" b3="TRAN_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUXMONT" b2="230 KV" b3="WHITHOS3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUXMONT" b2="230 KV" b3="BUX-WHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="230 KV" b3="J105 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8260</SeqNum>
    <Name>L230.Whitpain-Whitemarsh-Jenkintown.220-17</Name>
    <LastEdit Timestamp="2025-11-18T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINTO" b2="13 KV" b3="13TRLSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINTO" b2="230 KV" b3="220 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="JENKINTO" b2="230 KV" b3="JEN-WHI" />
      <ContingencyEquipment Action="X" Type="XF" b1="JENKINTO" b2="230 KV" b3="JENK13T" />
      <ContingencyEquipment Action="S" Type="SD" b1="WHITEMAR" b2="230 KV" b3="220-17" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHITEMAR" b2="230 KV" b3="DBU4" />
      <ContingencyEquipment Action="L" Type="LN" b1="WHITEMAR" b2="230 KV" b3="WHI-WHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="230 KV" b3="175 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8270</SeqNum>
    <Name>L230.Manitou-Whitings.V2022</Name>
    <LastEdit Timestamp="2025-08-25T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="230 KV" b3="AV" />
      <ContingencyEquipment Action="X" Type="XF" b1="MANITOU" b2="230 KV" b3="BK 1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MANITOU" b2="230 KV" b3="BK 6" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MANITOU" b2="230 KV" b3="BK1230CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="230 KV" b3="VN GC" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHITINGS" b2="230 KV" b3="BANK 4TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITINGS" b2="35 KV" b3="BK 4LCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITINGS" b2="230 KV" b3="BV GC" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANITOU" b2="230 KV" b3="MAN-WHI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8280</SeqNum>
    <Name>L230.Traynor-Whippany.Z1040</Name>
    <LastEdit Timestamp="2025-10-22T14:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRAYNOR" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRAYNOR" b2="230 KV" b3="BK 13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="230 KV" b3="B117" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="230 KV" b3="B34" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRAYNOR" b2="230 KV" b3="TRA-WHIZ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8290</SeqNum>
    <Name>L230.Traynor-Whippany.Y1039</Name>
    <LastEdit Timestamp="2025-10-22T14:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRAYNOR" b2="230 KV" b3="B71" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRAYNOR" b2="230 KV" b3="BK 14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="230 KV" b3="B114" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="230 KV" b3="B117" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRAYNOR" b2="230 KV" b3="TRA-WHIY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8300</SeqNum>
    <Name>L230.Roseland-Whippany.A-941</Name>
    <LastEdit Timestamp="2025-10-24T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="5-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="5-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="230 KV" b3="B114" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="230 KV" b3="B161" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROSELAND" b2="230 KV" b3="ROS-WHI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8310</SeqNum>
    <Name>L230.Greystone-Whippany.J1024</Name>
    <LastEdit Timestamp="2026-02-17T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREYSTON" b2="230 KV" b3="J1024 GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="230 KV" b3="B35" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="230 KV" b3="B57" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREYSTON" b2="230 KV" b3="GRE-WHIJ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8320</SeqNum>
    <Name>L230.Greystone-Whippany.Q1031 + 230/115.Whppny.12</Name>
    <LastEdit Timestamp="2025-02-18T15:21:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREYSTON" b2="230 KV" b3="B61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="230 KV" b3="B161" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="230 KV" b3="B57" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="115 KV" b3="B78" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHIPPANY" b2="230 KV" b3="BK 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHIPPANY" b2="230 KV" b3="BK 7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="230 KV" b3="BK 7 230" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREYSTON" b2="230 KV" b3="GRE-WHIQ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8330</SeqNum>
    <Name>L115.MaysChapel-Texas-WindyEdge.110509</Name>
    <LastEdit Timestamp="2025-07-28T11:59:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYSCHAP" b2="115 KV" b3="110509" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYSCHAP" b2="115 KV" b3="509-515" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TEXAS" b2="115 KV" b3="110509" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TEXAS" b2="115 KV" b3="5-6_509" />
      <ContingencyEquipment Action="CL" Type="CB" b1="TEXAS" b2="115 KV" b3="5-6_515A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TEXAS" b2="115 KV" b3="7TR_509" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAYSCHAP" b2="115 KV" b3="MAY-TEX9" />
      <ContingencyEquipment Action="L" Type="LN" b1="TEXAS" b2="115 KV" b3="TEX-WIN9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110509" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8340</SeqNum>
    <Name>L115.MaysChapel-Texas-WindyEdge.110515</Name>
    <LastEdit Timestamp="2025-07-28T11:59:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYSCHAP" b2="115 KV" b3="110515-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYSCHAP" b2="115 KV" b3="509-515" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAYSCHAP" b2="115 KV" b3="MAY-TEX5" />
      <ContingencyEquipment Action="CL" Type="CB" b1="TEXAS" b2="115 KV" b3="110509" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TEXAS" b2="115 KV" b3="110515-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TEXAS" b2="115 KV" b3="5-6_515A" />
      <ContingencyEquipment Action="CL" Type="CB" b1="TEXAS" b2="115 KV" b3="7TR_509" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TEXAS" b2="115 KV" b3="7TR_515A" />
      <ContingencyEquipment Action="L" Type="LN" b1="TEXAS" b2="115 KV" b3="TEX-WIN5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110515" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8350</SeqNum>
    <Name>L230.Linton-Woodbourne.220-59+230/35.Woodbourne.T7</Name>
    <LastEdit Timestamp="2025-06-06T11:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINTON" b2="35 KV" b3="335 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINTON" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINTON" b2="230 KV" b3="LIN 3TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODBOUR" b2="35 KV" b3="775 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODBOUR" b2="230 KV" b3="805 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINTON" b2="230 KV" b3="LIN-WOO" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODBOUR" b2="230 KV" b3="WDB 7TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8360</SeqNum>
    <Name>L115.Westport-GreeneStreet.110554</Name>
    <LastEdit Timestamp="2026-02-17T10:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="GREE BC" b2="115 KV" b3="110-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREE BC" b2="13 KV" b3="110-3LS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREE BC" b2="115 KV" b3="554_562" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="526-554" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREE BC" b2="115 KV" b3="GRE-WES4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8370</SeqNum>
    <Name>L115.Westport-GreeneStreet.110553</Name>
    <LastEdit Timestamp="2026-02-17T10:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="GREE BC" b2="115 KV" b3="110-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREE BC" b2="13 KV" b3="110-1LS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREE BC" b2="115 KV" b3="553_59" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="524-553" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREE BC" b2="115 KV" b3="GRE-WES3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8390</SeqNum>
    <Name>L230.Burlington-Bustleton-Crosswicks-WardAve.Y2356</Name>
    <LastEdit Timestamp="2025-05-27T17:34:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="1-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="2-11" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURLINGT" b2="230 KV" b3="BUR-BSTY" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUSTLETO" b2="230 KV" b3="BUS-CROY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUSTLETO" b2="230 KV" b3="T-2CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROSSWIC" b2="230 KV" b3="CRO-WARY" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROSSWIC" b2="13 KV" b3="CROSS1SP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CROSSWIC" b2="13 KV" b3="LOADT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSWIC" b2="230 KV" b3="T-1CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CROSSWIC" b2="13 KV" b3="T1LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROSSWIC" b2="230 KV" b3="TXR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARDAV" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARDAV" b2="230 KV" b3="L-Y" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8410</SeqNum>
    <Name>L115.WindyEdge-Glenarm-Colon-FiveForks.110511</Name>
    <LastEdit Timestamp="2024-05-15T08:43:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLONIAL" b2="115 KV" b3="511ABS" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLONIAL" b2="115 KV" b3="COL-GLE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLONIAL" b2="115 KV" b3="COL-ROC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIVEFORK" b2="115 KV" b3="511" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIVEFORK" b2="115 KV" b3="FIV-ROC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENARM" b2="115 KV" b3="1TR_511" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENARM" b2="115 KV" b3="GLE-WIN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKRIDG" b2="115 KV" b3="1_3TR511" />
      <ContingencyEquipment Action="CL" Type="CB" b1="ROCKRIDG" b2="115 KV" b3="1_3TR512" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKRIDG" b2="115 KV" b3="2TR511" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110511" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8420</SeqNum>
    <Name>L115.WindyEdge-Glenarm-Colon-FiveForks.110512</Name>
    <LastEdit Timestamp="2024-05-15T08:44:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="COLONIAL" b2="115 KV" b3="511ABS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLONIAL" b2="115 KV" b3="512ABS" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLONIAL" b2="115 KV" b3="COL-GLE2" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLONIAL" b2="115 KV" b3="COL-ROC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIVEFORK" b2="115 KV" b3="512" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIVEFORK" b2="115 KV" b3="FIV-ROC2" />
      <ContingencyEquipment Action="CL" Type="CB" b1="GLENARM" b2="115 KV" b3="1TR_511" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENARM" b2="115 KV" b3="1TR_512" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENARM" b2="115 KV" b3="GLE-WIN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKRIDG" b2="115 KV" b3="1_3TR512" />
      <ContingencyEquipment Action="CL" Type="CB" b1="ROCKRIDG" b2="115 KV" b3="2TR511" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKRIDG" b2="115 KV" b3="2TR512" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110512" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8430</SeqNum>
    <Name>L345.Gilboa-Leeds</Name>
    <LastEdit Timestamp="2026-02-17T11:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBOA" b2="345 KV" b3="3208" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBOA" b2="345 KV" b3="3214" />
      <ContingencyEquipment Action="L" Type="LN" b1="GILBOA" b2="345 KV" b3="GIL-LEE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEEDS" b2="345 KV" b3="R3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEEDS" b2="345 KV" b3="R395" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8440</SeqNum>
    <Name>230/69.Mickleton.T1</Name>
    <LastEdit Timestamp="2024-12-03T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="AF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="FF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="HH" />
      <ContingencyEquipment Action="X" Type="XF" b1="MICKLETO" b2="230 KV" b3="MICK #1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8450</SeqNum>
    <Name>L230.Brighton-MtZion-QuinceOrchard.23124/23024</Name>
    <LastEdit Timestamp="2026-02-17T10:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="230 KV" b3="2AB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIGHTON" b2="230 KV" b3="BRI-MTZ4" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTZION" b2="230 KV" b3="MTZ-NOR0" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTZION" b2="230 KV" b3="MTZ-QUI4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORBECK" b2="69 KV" b3="1TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORBECK" b2="69 KV" b3="1TS2B" />
      <ContingencyEquipment Action="X" Type="XF" b1="NORBECK" b2="230 KV" b3="NORBT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23024" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8460</SeqNum>
    <Name>L230.QuinceOrchard-BellsMillRoad.23029</Name>
    <LastEdit Timestamp="2026-02-17T11:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BELLSMIL" b2="230 KV" b3="121-13T" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLSMIL" b2="230 KV" b3="121-1T" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLSMIL" b2="230 KV" b3="121-5T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="69 KV" b3="13TS3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="69 KV" b3="13TS4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="34 KV" b3="1TS2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="34 KV" b3="1TS3B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BELLSMIL" b2="230 KV" b3="2 CAP" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLSMIL" b2="230 KV" b3="BEL-QUI9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23029B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8470</SeqNum>
    <Name>L230.BurchesHill-PalmersCorner.23093</Name>
    <LastEdit Timestamp="2025-05-06T05:23:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="1AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="1BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURCHESH" b2="230 KV" b3="BUR-PAL3" />
      <ContingencyEquipment Action="X" Type="XF" b1="PALMERS" b2="230 KV" b3="084-1T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="69 KV" b3="1TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="69 KV" b3="1TS2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="230 KV" b3="23089B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="230 KV" b3="23108B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8480</SeqNum>
    <Name>L230.WWharton-DOTWhar-Elstimold-Pohatcong</Name>
    <LastEdit Timestamp="2026-02-27T15:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DOTWWHAR" b2="230 KV" b3="DOT-ELA" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOTWWHAR" b2="230 KV" b3="DOT-WWH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOTWWHAR" b2="230 KV" b3="TE TX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELASTIMO" b2="230 KV" b3="1 TX" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELASTIMO" b2="230 KV" b3="ELA-POH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POHATCON" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="230 KV" b3="1A3 GCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="230 KV" b3="B54" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8490</SeqNum>
    <Name>L115.ConcordStreet-MonumentStreet.110564</Name>
    <LastEdit Timestamp="2025-02-26T14:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CONC BC" b2="115 KV" b3="110-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC BC" b2="13 KV" b3="110-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC BC" b2="115 KV" b3="567564CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC BC" b2="13 KV" b3="TIE CB2" />
      <ContingencyEquipment Action="X" Type="XF" b1="MONUMEST" b2="115 KV" b3="110-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONUMEST" b2="115 KV" b3="110-4HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONUMEST" b2="115 KV" b3="110-6HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONUMEST" b2="115 KV" b3="557_564" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONC BC" b2="115 KV" b3="CON-MON" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONUMEST" b2="13 KV" b3="FOUR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONUMEST" b2="115 KV" b3="SIX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8500</SeqNum>
    <Name>L230.Branchburg-SunnymeadeRoad-BennettsLane.X-2224</Name>
    <LastEdit Timestamp="2026-02-17T10:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNETTS" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BENNETTS" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNETTS" b2="230 KV" b3="T-2 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANCHBU" b2="230 KV" b3="BRA-SUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT 7-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT1-7" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENNETTS" b2="230 KV" b3="BEN-SUN" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUNNYMEA" b2="230 KV" b3="T12TRANS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUNNYMEA" b2="230 KV" b3="T34TRANS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUNNYMEA" b2="230 KV" b3="TRANT1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUNNYMEA" b2="230 KV" b3="TRANT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8510</SeqNum>
    <Name>L230.Buckingham-Rocktown.220-12</Name>
    <LastEdit Timestamp="2026-02-17T10:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKINGH" b2="230 KV" b3="230 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKINGH" b2="230 KV" b3="BUCK-ROC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKTOWN" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKTOWN" b2="230 KV" b3="B9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8520</SeqNum>
    <Name>L500.Branchburg-Deans.5019</Name>
    <LastEdit Timestamp="2025-01-15T18:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRANCHBU" b2="500 KV" b3="BRA-DEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="500 KV" b3="SECT 3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="500 KV" b3="SECT 4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="500 KV" b3="SECT 2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="500 KV" b3="SECT 3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8530</SeqNum>
    <Name>L230.Mickleton-DelcoTp-Trainer.220-38 + Delco.Unit</Name>
    <LastEdit Timestamp="2025-04-23T15:51:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DELCOTAP" b2="230 KV" b3="1 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELCOTAP" b2="230 KV" b3="185 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELCOTAP" b2="230 KV" b3="DEL-MIC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DELCOTAP" b2="230 KV" b3="DELC1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELCOTAP" b2="13 KV" b3="DELCO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="DT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="V" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRAINER" b2="230 KV" b3="3BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRAINER" b2="230 KV" b3="875 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELCOTAP" b2="230 KV" b3="DEL-TRA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8540</SeqNum>
    <Name>L138.FederalSquare-Newark.G-1359</Name>
    <LastEdit Timestamp="2025-08-04T13:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FEDERALS" b2="138 KV" b3="132-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FEDERALS" b2="138 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="FEDERALS" b2="138 KV" b3="FED-NEW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8560</SeqNum>
    <Name>L230.Graceton-FvFrks.110510 + 230/115.Grctn.230-1</Name>
    <LastEdit Timestamp="2024-05-15T08:45:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FIVEFORK" b2="115 KV" b3="511" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIVEFORK" b2="115 KV" b3="512" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIVEFORK" b2="115 KV" b3="FIV-GRA" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIVEFORK" b2="115 KV" b3="FIV-ROC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIVEFORK" b2="115 KV" b3="FIV-ROC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIVEFORK" b2="115 KV" b3="TIE" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRACETON" b2="230 KV" b3="230-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRACETON" b2="230 KV" b3="230-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRACETON" b2="230 KV" b3="2305-1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8570</SeqNum>
    <Name>L230.Granite-Howard-Columbia-HighRidge.2312</Name>
    <LastEdit Timestamp="2026-04-22T16:28:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="COLU BC" b2="230 KV" b3="1TR-2318" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COLU BC" b2="230 KV" b3="1TR-2320" />
      <ContingencyEquipment Action="S" Type="SD" b1="COLU BC" b2="230 KV" b3="2312 SD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU BC" b2="230 KV" b3="2320CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="COLU BC" b2="230 KV" b3="24TR2318" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COLU BC" b2="230 KV" b3="24TR2320" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLU BC" b2="230 KV" b3="COL-HIG" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLU BC" b2="230 KV" b3="COL-HOW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="115 KV" b3="110529" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="115 KV" b3="110560-A" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRANITE" b2="230 KV" b3="230-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="230 KV" b3="2311_12" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANITE" b2="230 KV" b3="GRA-HOW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="2312B43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="2312CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HOWARD" b2="230 KV" b3="1-2TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD" b2="230 KV" b3="2312 GCB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="SNOWDENR" b2="230 KV" b3="230TIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SNOWDENR" b2="230 KV" b3="2320-A" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SNOWDENR" b2="230 KV" b3="DUMHIG" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="WILDELAK" b2="230 KV" b3="1TR-1BUS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WILDELAK" b2="230 KV" b3="1TR-2BUS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="WILDELAK" b2="230 KV" b3="2TR-1BUS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="WILDELAK" b2="230 KV" b3="3TR-1BUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8610</SeqNum>
    <Name>230/69.Hosensack.T1</Name>
    <LastEdit Timestamp="2026-02-19T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HOSENSAC" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="230 KV" b3="TRAN_1-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="230 KV" b3="TRAN_1-W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="69 KV" b3="TRAN_1_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="69 KV" b3="TRAN_1_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8630</SeqNum>
    <Name>L230.Grnt-Hwrd-Pmphry-HghRg.2332 + 230/115.Pmphr.1</Name>
    <LastEdit Timestamp="2026-02-17T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="230 KV" b3="2326_32" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANITE" b2="230 KV" b3="GRA-HOW3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="23052332" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="2332A CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHRIDG" b2="230 KV" b3="HIG-HOW" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HOWARD" b2="230 KV" b3="1-2TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD" b2="230 KV" b3="2332 GCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOWARD" b2="230 KV" b3="HOW-PUM" />
      <ContingencyEquipment Action="X" Type="XF" b1="PUMPHREY" b2="230 KV" b3="230-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="230-1OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="519_1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8650</SeqNum>
    <Name>L230.Sayreville-Kilmer-LakeNelson.W-1037</Name>
    <LastEdit Timestamp="2025-12-10T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KILMER" b2="230 KV" b3="KIL-LAKW" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KILMER" b2="230 KV" b3="T12TRANS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KILMER" b2="230 KV" b3="T34TRANS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KILMER" b2="230 KV" b3="TRAN T-1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KILMER" b2="230 KV" b3="TRAN T-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKENELS" b2="230 KV" b3="W1037 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="KILMER" b2="230 KV" b3="KIL-SAYW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8670</SeqNum>
    <Name>L230.Mickleton-Thorofare-EaglePoint.O-2241</Name>
    <LastEdit Timestamp="2024-11-21T09:02:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLEPT" b2="230 KV" b3="100" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLEPT" b2="230 KV" b3="102" />
      <ContingencyEquipment Action="L" Type="LN" b1="EAGLEGEN" b2="230 KV" b3="EAG-EAG2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EAGLEPT" b2="230 KV" b3="EAG-THOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="BV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="GQ" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="THOROFAR" b2="230 KV" b3="DUMD1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="THOROFAR" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="MICKLETO" b2="230 KV" b3="MIC-THO" />
      <ContingencyEquipment Action="U" Type="GEN" b1="THOROFAR" b2="230 KV" b3="THOROFSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOROFAR" b2="230 KV" b3="TRANT-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8680</SeqNum>
    <Name>230/69.Mickleton.T4</Name>
    <LastEdit Timestamp="2025-03-26T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="AN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="BE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="EE" />
      <ContingencyEquipment Action="X" Type="XF" b1="MICKLETO" b2="230 KV" b3="MICK #4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="MK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8690</SeqNum>
    <Name>L230.Roseland-WCaldwel-Cook-TurnPke-Kearny.M-2318</Name>
    <LastEdit Timestamp="2026-02-19T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COOKRD" b2="230 KV" b3="COO-TURM" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="COOKRD" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="17-21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="21-22" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEARNY" b2="230 KV" b3="KEA-TURM" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="TURNPIKE" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOKRD" b2="230 KV" b3="COO-WCAM" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROSELAND" b2="230 KV" b3="ROS-WCAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCALDWEL" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="WCALDWEL" b2="230 KV" b3="T1-2TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCALDWEL" b2="230 KV" b3="T3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="WCALDWEL" b2="230 KV" b3="T3-4TRAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8730</SeqNum>
    <Name>L230.Roseland-WCaldwell-Kingsland.K-2316</Name>
    <LastEdit Timestamp="2025-02-03T19:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSLAN" b2="230 KV" b3="1-2CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGSLAN" b2="230 KV" b3="KIN-KNSW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSLAN" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSLSW" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="17-19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="19-20" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROSELAND" b2="230 KV" b3="ROS-WCAK" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGSLSW" b2="230 KV" b3="KNS-WCAL" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="WCALDWEL" b2="230 KV" b3="T1-2TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCALDWEL" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="WCALDWEL" b2="230 KV" b3="T3-4TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCALDWEL" b2="230 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8740</SeqNum>
    <Name>L230.PlymouthMeeting-WhiteMarsh-Pulaski.220-41</Name>
    <LastEdit Timestamp="2025-11-18T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="230 KV" b3="415 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLYMOUTH" b2="230 KV" b3="PLY-WHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PULASKI" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PULASKI" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PULASKI" b2="13 KV" b3="LD 1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="PULASKI" b2="230 KV" b3="PULS1TR" />
      <ContingencyEquipment Action="S" Type="SD" b1="WHITEMAR" b2="230 KV" b3="220-41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEMAR" b2="230 KV" b3="75 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHITEMAR" b2="230 KV" b3="DBU6" />
      <ContingencyEquipment Action="L" Type="LN" b1="PULASKI" b2="230 KV" b3="PUL-WHI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8750</SeqNum>
    <Name>L230.Northeast-Riverside.2339</Name>
    <LastEdit Timestamp="2026-02-19T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="230 KV" b3="2339CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHEAS" b2="230 KV" b3="NOR-RIV9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="230 KV" b3="2339_44" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8760</SeqNum>
    <Name>230/115.Riverside.230-1</Name>
    <LastEdit Timestamp="2025-11-21T12:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="115 KV" b3="110981" />
      <ContingencyEquipment Action="S" Type="SD" b1="RIVERSID" b2="115 KV" b3="115011" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIVERSID" b2="230 KV" b3="230-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="115 KV" b3="230-1OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="230 KV" b3="2339_44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="230 KV" b3="2344GCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8780</SeqNum>
    <Name>230/115.Riverside.230-2</Name>
    <LastEdit Timestamp="2025-11-21T12:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="115 KV" b3="110982" />
      <ContingencyEquipment Action="S" Type="SD" b1="RIVERSID" b2="115 KV" b3="115012" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIVERSID" b2="230 KV" b3="230-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="115 KV" b3="230-2OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="230 KV" b3="2317OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="230 KV" b3="2345OCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8790</SeqNum>
    <Name>L230.Whitpain-Roxborough-Westmoreland.220-65</Name>
    <LastEdit Timestamp="2025-12-23T07:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="ROXBOROU" b2="230 KV" b3="220-65" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBOROU" b2="69 KV" b3="235 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROXBOROU" b2="230 KV" b3="ROX 3TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROXBOROU" b2="230 KV" b3="ROX-WMO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="230 KV" b3="655 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROXBOROU" b2="230 KV" b3="ROX-WHI" />
      <ContingencyEquipment Action="X" Type="XF" b1="WMORELAN" b2="230 KV" b3="11TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="13 KV" b3="11TRLSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="230 KV" b3="705 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8800</SeqNum>
    <Name>L230.NorthPhiladelphia-Westmoreland.220-77</Name>
    <LastEdit Timestamp="2025-05-22T13:44:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="230 KV" b3="655 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="NPHILADE" b2="230 KV" b3="NPH-WMO1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WMORELAN" b2="230 KV" b3="13TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="13 KV" b3="13TRLSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="230 KV" b3="905 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8830</SeqNum>
    <Name>L230.Steelton-Hummelstown-MiddletownJct.1002</Name>
    <LastEdit Timestamp="2024-11-27T11:17:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="230 KV" b3="SDMIJUSF" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUMMELST" b2="230 KV" b3="HUM-HUM" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUMMETAP" b2="230 KV" b3="HUM-MID2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUMMETAP" b2="230 KV" b3="HUM-STE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B77" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELTON" b2="230 KV" b3="HUMM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STEELTON" b2="230 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8840</SeqNum>
    <Name>L230.Burtonsville-Bowie.23044</Name>
    <LastEdit Timestamp="2026-02-17T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="230 KV" b3="23044B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOWIE" b2="230 KV" b3="BOW-BUR4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="23044B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8850</SeqNum>
    <Name>L230.Burtonsville-Bowie.23043</Name>
    <LastEdit Timestamp="2026-02-17T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="230 KV" b3="23043B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOWIE" b2="230 KV" b3="BOW-BUR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="23043B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8860</SeqNum>
    <Name>230/13.Conowingo.GSU.TR5-6 + Conowingo.U8-U11</Name>
    <LastEdit Timestamp="2025-12-01T13:33:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="10GEN CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="11GEN CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="230 KV" b3="220-03CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="8 GEN CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="9 GEN CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="230 KV" b3="BUSTIE D" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONOWING" b2="230 KV" b3="CONO5TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONOWING" b2="230 KV" b3="CONO6TR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONOWING" b2="13 KV" b3="COPCOLD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="G10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="G11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN8" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8870</SeqNum>
    <Name>L230.Conowingo-Nottingham-220-03</Name>
    <LastEdit Timestamp="2025-08-26T17:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="230 KV" b3="220-03CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONOWING" b2="230 KV" b3="CON-NOT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTTINGH" b2="230 KV" b3="035" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8880</SeqNum>
    <Name>L230.Betzwood-Cromby.220-63</Name>
    <LastEdit Timestamp="2025-10-16T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETZWOOD" b2="230 KV" b3="635" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETZWOOD" b2="230 KV" b3="BET-CRO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="69 KV" b3="455 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="230 KV" b3="575 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="230 KV" b3="615 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="35 KV" b3="75" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROMBY" b2="230 KV" b3="CROM5TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROMBY" b2="230 KV" b3="CROM7TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8890</SeqNum>
    <Name>L230.NewFreedom-Echelon.E-2336</Name>
    <LastEdit Timestamp="2024-11-06T15:29:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ECHELON" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ECHELON" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="ECHELON" b2="230 KV" b3="ECH-NEWF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="11_12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="230 2-12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8900</SeqNum>
    <Name>L230.Croydon-Burlington.D-220-30</Name>
    <LastEdit Timestamp="2024-10-28T12:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="2-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="230-10CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BURLINGT" b2="230 KV" b3="230-10LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURLINGT" b2="230 KV" b3="BUR-CRO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="230 KV" b3="115 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="230 KV" b3="215 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8920</SeqNum>
    <Name>L230.Smithburg-EastWindsor.E-2005</Name>
    <LastEdit Timestamp="2025-04-01T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="230 KV" b3="B40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="230 KV" b3="FE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHBUR" b2="230 KV" b3="B25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHBUR" b2="230 KV" b3="ED GC" />
      <ContingencyEquipment Action="L" Type="LN" b1="EWINDSOR" b2="230 KV" b3="EWI-SMI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8930</SeqNum>
    <Name>L230.EastWindsor-Windsor.F2006</Name>
    <LastEdit Timestamp="2025-07-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="230 KV" b3="2F" />
      <ContingencyEquipment Action="L" Type="LN" b1="EWINDSOR" b2="230 KV" b3="EWI-WIN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="230 KV" b3="FE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND JC" b2="230 KV" b3="B57" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND JC" b2="230 KV" b3="B61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8950</SeqNum>
    <Name>Linden.U5&amp;U6</Name>
    <LastEdit Timestamp="2025-01-30T15:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="230 KV" b3="BK 56-P" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINDEN" b2="13 KV" b3="UNIT05" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINDEN" b2="13 KV" b3="UNIT06" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8960</SeqNum>
    <Name>L115.Orchards-Center.110589 + 115/13.Center.T3</Name>
    <LastEdit Timestamp="2026-02-19T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CENTER" b2="115 KV" b3="110-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTER" b2="115 KV" b3="552589CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTER" b2="115 KV" b3="555589GC" />
      <ContingencyEquipment Action="CL" Type="CB" b1="CENTER" b2="13 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTER" b2="115 KV" b3="CEN-ORC9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTER" b2="13 KV" b3="DUM3LSBK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="110589" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="589_598" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8970</SeqNum>
    <Name>L230.Northeast-RaphaelRoad.2315</Name>
    <LastEdit Timestamp="2026-02-19T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="230 KV" b3="2315CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHEAS" b2="230 KV" b3="NOR-RAP5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPHAERD" b2="230 KV" b3="2305_15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPHAERD" b2="230 KV" b3="2315" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8980</SeqNum>
    <Name>L115.NorthEast-HoneyGo-WindyEdgeWest.110581</Name>
    <LastEdit Timestamp="2025-03-11T06:16:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HONEYGO" b2="115 KV" b3="1TR_581" />
      <ContingencyEquipment Action="CL" Type="CB" b1="HONEYGO" b2="115 KV" b3="1_2TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="HONEYGO" b2="115 KV" b3="HON-WIN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHEAS" b2="115 KV" b3="NOR-HON1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="1101-581" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="110581" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110581" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WINDYEDG" b2="115 KV" b3="115TIE" />
      <ContingencyEquipment Action="S" Type="SD" b1="WINDYEDG" b2="115 KV" b3="581SD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>8990</SeqNum>
    <Name>L115.NorthEast-WindyEdgeEast.110582</Name>
    <LastEdit Timestamp="2025-02-18T11:36:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="HONEYGO" b2="115 KV" b3="1_2TIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HONEYGO" b2="115 KV" b3="2TR_582" />
      <ContingencyEquipment Action="L" Type="LN" b1="HONEYGO" b2="115 KV" b3="HON-WIN2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHEAS" b2="115 KV" b3="NOR-HON2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="582-591" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="582_-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110582" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="WINDYEDG" b2="115 KV" b3="115TIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WINDYEDG" b2="115 KV" b3="1TR_582" />
      <ContingencyEquipment Action="S" Type="SD" b1="WINDYEDG" b2="115 KV" b3="582SD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9000</SeqNum>
    <Name>L345.Waldwick-SouthMahwah-Ramapo.J-3410/69</Name>
    <LastEdit Timestamp="2026-02-20T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="2500-69" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="69-2Y" />
      <ContingencyEquipment Action="L" Type="LN" b1="RAMAPO" b2="345 KV" b3="RAM-SMA9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="345 KV" b3="T258_J34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="345 KV" b3="345SC1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="345 KV" b3="345SC5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="SMAWA" b2="345 KV" b3="SMA-WALJ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9010</SeqNum>
    <Name>L345.Waldwick-SouthMahwah-Ramapo.K-3411/70</Name>
    <LastEdit Timestamp="2026-02-19T10:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="70-2Y" />
      <ContingencyEquipment Action="L" Type="LN" b1="RAMAPO" b2="345 KV" b3="RAM-SMA0" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="T-70-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="345 KV" b3="345SC1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="345 KV" b3="345SC7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="SMAWA" b2="345 KV" b3="SMA-WALK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9020</SeqNum>
    <Name>L115.Westport-Center.110552</Name>
    <LastEdit Timestamp="2025-07-23T16:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CENTER" b2="115 KV" b3="110-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTER" b2="115 KV" b3="552556OC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTER" b2="115 KV" b3="552589CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="CENTER" b2="13 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTER" b2="115 KV" b3="CEN-WES2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTER" b2="13 KV" b3="DUM2LSBK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="10552TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="110552" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9030</SeqNum>
    <Name>230/138.Trenton.220-6+L138.Trenton-SteelTap-Biles</Name>
    <LastEdit Timestamp="2025-02-03T19:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BILES" b2="138 KV" b3="20" />
      <ContingencyEquipment Action="L" Type="LN" b1="BILES" b2="138 KV" b3="BIL-STE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELTAP" b2="138 KV" b3="30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="2-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="TRENTON" b2="230 KV" b3="220-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="STEELTAP" b2="138 KV" b3="STE-TRE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9040</SeqNum>
    <Name>L230.Cookstown-Manchester-Whitings.B1042</Name>
    <LastEdit Timestamp="2026-03-19T14:08:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOKSTOW" b2="230 KV" b3="B154" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOKSTOW" b2="230 KV" b3="B39" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOKSTOW" b2="230 KV" b3="COO-MANC" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANCHEST" b2="230 KV" b3="MAN-WHI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MANCHEST" b2="230 KV" b3="T1_LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MANCHEST" b2="230 KV" b3="T2_LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHITINGS" b2="230 KV" b3="BANK 5TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITINGS" b2="230 KV" b3="BV GC" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WHITINGS" b2="35 KV" b3="DUM20255" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9050</SeqNum>
    <Name>230/69.SilverLake.T2</Name>
    <LastEdit Timestamp="2026-02-19T10:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERLA" b2="230 KV" b3="OCB C" />
      <ContingencyEquipment Action="X" Type="XF" b1="SILVERLA" b2="230 KV" b3="SILV #2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERLA" b2="69 KV" b3="XFMROCBL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9060</SeqNum>
    <Name>L230.Morgantown-Hawkins-KelsonRidge.23076/84</Name>
    <LastEdit Timestamp="2025-03-05T16:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HAWKINS" b2="230 KV" b3="HAW-HAW4" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAWKINS" b2="230 KV" b3="HAW-KEL" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAWKINS" b2="230 KV" b3="HAW-MOR6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSONRI" b2="230 KV" b3="1C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSONRI" b2="230 KV" b3="1D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="9BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="9CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9070</SeqNum>
    <Name>L230.CedarGrove-CedarSub-William.F-2206</Name>
    <LastEdit Timestamp="2026-02-19T10:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARSUB" b2="230 KV" b3="CED-CEDF" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARSUB" b2="230 KV" b3="CED-WILF" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CEDARSUB" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLIAM1" b2="230 KV" b3="SC2-3CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLIAM1" b2="230 KV" b3="SC3-4CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9080</SeqNum>
    <Name>L230.Cromby-UpperProvidence.220-62</Name>
    <LastEdit Timestamp="2026-02-25T10:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="69 KV" b3="365 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CROMBY" b2="230 KV" b3="6-4 CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="230 KV" b3="605 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROMBY" b2="230 KV" b3="CROM6TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERPRO" b2="230 KV" b3="625" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROMBY" b2="230 KV" b3="CRO-UPP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9110</SeqNum>
    <Name>L230.Cumberland-Juniata.2235</Name>
    <LastEdit Timestamp="2026-01-06T13:36:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CUMB PL" b2="230 KV" b3="CUM-JUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="230 KV" b3="JUNI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="230 KV" b3="TR2_JUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="230 KV" b3="CUMB1_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="230 KV" b3="CUMB1_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9120</SeqNum>
    <Name>500/230.ChalkPoint.T5</Name>
    <LastEdit Timestamp="2026-02-19T10:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="500 KV" b3="10BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="500 KV" b3="10CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHALKPT" b2="500 KV" b3="500-5T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="7AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="7BB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9130</SeqNum>
    <Name>500/230.ChalkPoint.T6</Name>
    <LastEdit Timestamp="2026-02-19T10:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="500 KV" b3="11BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="500 KV" b3="11CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHALKPT" b2="500 KV" b3="500-6T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="8AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="8BB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9140</SeqNum>
    <Name>L230.DickersonH-QuinceOrchard.23034</Name>
    <LastEdit Timestamp="2026-02-19T10:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSH" b2="230 KV" b3="44B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSH" b2="230 KV" b3="44C" />
      <ContingencyEquipment Action="L" Type="LN" b1="DICKERSH" b2="230 KV" b3="DIC-QUI4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23034B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9150</SeqNum>
    <Name>L230.QuinceOrchard-BellsMillRoad.23030</Name>
    <LastEdit Timestamp="2026-02-19T10:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BELLSMIL" b2="230 KV" b3="121-12T" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLSMIL" b2="230 KV" b3="121-3T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="69 KV" b3="12TS2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="69 KV" b3="12TS3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BELLSMIL" b2="230 KV" b3="3 CAP" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLSMIL" b2="230 KV" b3="BEL-QUI0" />
      <ContingencyEquipment Action="X" Type="XF" b1="QUINCEOR" b2="230 KV" b3="118-3T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23025B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23035B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="69 KV" b3="69K7B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="69 KV" b3="69K8B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9160</SeqNum>
    <Name>L230.BurchHill-OakGrove-Talbert-KelsnRdge.68/86/81</Name>
    <LastEdit Timestamp="2025-02-28T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="1BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSONRI" b2="230 KV" b3="2A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSONRI" b2="230 KV" b3="2B" />
      <ContingencyEquipment Action="L" Type="LN" b1="KELSONRI" b2="230 KV" b3="KEL-TAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="9BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="9CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKGROVE" b2="230 KV" b3="OAK-TAL8" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURCHESH" b2="230 KV" b3="BUR-TAL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9170</SeqNum>
    <Name>L230.Morgantwn-Talbert-OakGrove-BurchHill.85/67/82</Name>
    <LastEdit Timestamp="2026-02-20T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="2BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="6BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="6CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="7AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="7CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKGROVE" b2="230 KV" b3="OAK-TAL7" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURCHESH" b2="230 KV" b3="BUR-TAL2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORGANTO" b2="230 KV" b3="MOR-TAL5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9180</SeqNum>
    <Name>L345.Ashtabula-ErieWest</Name>
    <LastEdit Timestamp="2026-04-17T08:32:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="345 KV" b3="B246" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="345 KV" b3="B249" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASHTABUL" b2="345 KV" b3="ASH-ERI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="345 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="345 KV" b3="B8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9190</SeqNum>
    <Name>345/115.ErieWest.T1</Name>
    <LastEdit Timestamp="2025-04-07T15:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="115 KV" b3="B139" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="115 KV" b3="B142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="345 KV" b3="B60" />
      <ContingencyEquipment Action="X" Type="XF" b1="ERIEW" b2="345 KV" b3="NO1 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9210</SeqNum>
    <Name>L115.Burma-Piney + 138/115.Burma.T1</Name>
    <LastEdit Timestamp="2025-01-10T12:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BURMA" b2="115 KV" b3="BUR-PIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURMA" b2="138 KV" b3="PINEY138" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURMA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEY" b2="115 KV" b3="BURMA115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEY" b2="115 KV" b3="BURMAAX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9220</SeqNum>
    <Name>L115.NorthMeshoppen-Lenox</Name>
    <LastEdit Timestamp="2024-11-27T10:56:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LENOX" b2="115 KV" b3="N MESHOP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="115 KV" b3="B98" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="115 KV" b3="B99" />
      <ContingencyEquipment Action="L" Type="LN" b1="LENOX" b2="115 KV" b3="LEN-NME" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9230</SeqNum>
    <Name>L230.Maywood-NewMilford.J-2236</Name>
    <LastEdit Timestamp="2025-07-07T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MAYWOOD" b2="13 KV" b3="MAYWOOSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYWOOD" b2="230 KV" b3="SECT1-3" />
      <ContingencyEquipment Action="X" Type="XF" b1="MAYWOOD" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MAYWOOD" b2="230 KV" b3="T3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAYWOOD" b2="13 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAYWOOD" b2="13 KV" b3="TR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWMILFR" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWMILFR" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAYWOOD" b2="230 KV" b3="MAY-NEW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9250</SeqNum>
    <Name>L230.Kittatinny-Newton.T2298</Name>
    <LastEdit Timestamp="2025-01-20T17:29:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTATIN" b2="230 KV" b3="TK AC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTATIN" b2="230 KV" b3="VT AC" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWTON" b2="230 KV" b3="BK1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NEWTON" b2="34.5 KV" b3="DUM4" />
      <ContingencyEquipment Action="L" Type="LN" b1="KITTATIN" b2="230 KV" b3="KIT-NEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTON" b2="230 KV" b3="NT GC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9270</SeqNum>
    <Name>L230.Hudson-Penhorn-Homestead-NBergen.X-2250</Name>
    <LastEdit Timestamp="2025-09-16T14:22:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HOMESTEA" b2="230 KV" b3="HOM-NBE" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOMESTEA" b2="230 KV" b3="HOM-PEN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMESTEA" b2="230 KV" b3="TRAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMESTEA" b2="230 KV" b3="TRAN4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="2-13" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUDSON" b2="230 KV" b3="HUD-PENT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBERGEN" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NBERGEN" b2="230 KV" b3="T40" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENHORN" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENHORN" b2="230 KV" b3="T-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENHORN" b2="230 KV" b3="TRAN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9280</SeqNum>
    <Name>L230.PleasantValley-Rocktown.Z-2357</Name>
    <LastEdit Timestamp="2026-02-20T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLVY PS" b2="230 KV" b3="SECT1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLVY PS" b2="230 KV" b3="SECT2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKTOWN" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKTOWN" b2="230 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLVY PS" b2="230 KV" b3="PLVY-ROC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9290</SeqNum>
    <Name>L230.Pohatcong-Kittatinny.L2012</Name>
    <LastEdit Timestamp="2026-03-27T09:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTATIN" b2="230 KV" b3="B100" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTATIN" b2="230 KV" b3="B119" />
      <ContingencyEquipment Action="L" Type="LN" b1="KITTATIN" b2="230 KV" b3="KIT-POH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POHATCON" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POHATCON" b2="34.5 KV" b3="DUM01" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POHATCON" b2="34.5 KV" b3="DUM02" />
      <ContingencyEquipment Action="X" Type="XF" b1="POHATCON" b2="230 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9300</SeqNum>
    <Name>L500.Keeney-RedLion.5036</Name>
    <LastEdit Timestamp="2025-09-04T14:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="500 KV" b3="503" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="500 KV" b3="508" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEENEY" b2="500 KV" b3="KEE-RED1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="500 KV" b3="501" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="500 KV" b3="502" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9310</SeqNum>
    <Name>L230.WaughChapel-BrandonShores.2342</Name>
    <LastEdit Timestamp="2025-10-06T11:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="2342 OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="23422392" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDONS" b2="230 KV" b3="BRA-WAU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="230-1_42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="2342OCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9320</SeqNum>
    <Name>L230.BrandonShores-WaughChapel.2343</Name>
    <LastEdit Timestamp="2025-10-06T11:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="2343 OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="23432391" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDONS" b2="230 KV" b3="BRA-WAU3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="230-3_43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="2343OCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9330</SeqNum>
    <Name>L230.DickersonH-Dickerson.23103</Name>
    <LastEdit Timestamp="2026-02-20T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSH" b2="230 KV" b3="42A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSO" b2="230 KV" b3="6 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DICKERSH" b2="230 KV" b3="DIC-DIC3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9340</SeqNum>
    <Name>L230.DickersonH-Dickerson.23104</Name>
    <LastEdit Timestamp="2026-02-20T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSH" b2="230 KV" b3="42C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSO" b2="230 KV" b3="5AB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DICKERSH" b2="230 KV" b3="DIC-DIC4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9350</SeqNum>
    <Name>L115.FarmersValley-Ridgeway</Name>
    <LastEdit Timestamp="2025-12-26T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMERSV" b2="115 KV" b3="B32" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMERSV" b2="115 KV" b3="FAR-RID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDG PN" b2="115 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RIDG PN" b2="115 KV" b3="D10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9370</SeqNum>
    <Name>L230.Eldred-Frackville+Eldred.T2</Name>
    <LastEdit Timestamp="2025-02-08T08:27:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ELDRED" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELDRED" b2="230 KV" b3="ELD-FRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDRED" b2="230 KV" b3="SUNBLINE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDRED" b2="69 KV" b3="TRAN_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="230 KV" b3="ELDR_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="230 KV" b3="ELDR_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9380</SeqNum>
    <Name>L230.Croydon-China-Emilie.220-54 + Emilie.TR6</Name>
    <LastEdit Timestamp="2025-03-27T15:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHINA" b2="230 KV" b3="1TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHINA" b2="230 KV" b3="CHI-CRO" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHINA" b2="230 KV" b3="CHI-EMI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="230 KV" b3="215 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="230 KV" b3="315 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="35 KV" b3="40 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="230 KV" b3="545 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="EMILIE" b2="230 KV" b3="EMIL6TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9390</SeqNum>
    <Name>L230.Burtonsville-SandySprings-HighRidge.2334</Name>
    <LastEdit Timestamp="2025-06-26T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="2D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="4D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="23342302" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="2334CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHRIDG" b2="230 KV" b3="HIG-SAN3" />
      <ContingencyEquipment Action="CL" Type="CB" b1="SANDYSPG" b2="230 KV" b3="1_2TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDYSPG" b2="230 KV" b3="2334 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURTONSV" b2="230 KV" b3="BUR-SAN3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9400</SeqNum>
    <Name>L230.HighRidge-SandySprings-Burtonsville.2314</Name>
    <LastEdit Timestamp="2025-06-26T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="1D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="3D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="23142304" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="2314CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHRIDG" b2="230 KV" b3="HIG-SAN1" />
      <ContingencyEquipment Action="CL" Type="CB" b1="SANDYSPG" b2="230 KV" b3="1_2TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDYSPG" b2="230 KV" b3="2314 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURTONSV" b2="230 KV" b3="BUR-SAN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9410</SeqNum>
    <Name>L230.Heaton-Jarrett.220-51 + 230/13.Jarrett.T2 </Name>
    <LastEdit Timestamp="2025-01-15T18:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="230 KV" b3="705 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="HEATON" b2="230 KV" b3="HEA 8TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEATON" b2="230 KV" b3="HEA-JAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HEATON" b2="230 KV" b3="XFMR5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JARRET" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JARRET" b2="230 KV" b3="565 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="JARRET" b2="230 KV" b3="JARRET2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9420</SeqNum>
    <Name>L230.Buckingham-Warminster.220-50</Name>
    <LastEdit Timestamp="2025-09-08T09:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKINGH" b2="230 KV" b3="210 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKINGH" b2="35 KV" b3="30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKINGH" b2="35 KV" b3="50 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKINGH" b2="230 KV" b3="BUC-WRM" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUCKINGH" b2="230 KV" b3="BUCK3TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUCKINGH" b2="230 KV" b3="BUCK5TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARMINST" b2="230 KV" b3="125 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARMINST" b2="230 KV" b3="535 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9430</SeqNum>
    <Name>L230.Warminster-Heaton.220-57</Name>
    <LastEdit Timestamp="2026-02-25T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="230 KV" b3="905 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEATON" b2="230 KV" b3="HEA-WRM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARMINST" b2="230 KV" b3="125 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARMINST" b2="13 KV" b3="14TRLS C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARMINST" b2="13 KV" b3="16TRLSCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WARMINST" b2="230 KV" b3="WRM14TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="WARMINST" b2="230 KV" b3="WRM16TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9440</SeqNum>
    <Name>L230.Linden-Tosco.B-2254</Name>
    <LastEdit Timestamp="2024-11-07T00:42:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINDEN" b2="230 KV" b3="LIN-TOS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOCB" b2="230 KV" b3="BUSTIECB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOCB" b2="230 KV" b3="CB2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TOSCOCB" b2="230 KV" b3="TOS-TOS2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9450</SeqNum>
    <Name>L230.Tosco-VFT St.2271</Name>
    <LastEdit Timestamp="2025-04-14T10:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOCB" b2="230 KV" b3="BUSTIECB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOCB" b2="230 KV" b3="CB1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TOSCOCB" b2="230 KV" b3="TOS-VFT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VFT_ST" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VFT_ST" b2="230 KV" b3="1-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9460</SeqNum>
    <Name>L230.Warinanco-VFT_ST.U-2273</Name>
    <LastEdit Timestamp="2025-05-16T11:05:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VFT_ST" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VFT_ST" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="WARINANC" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARINANC" b2="230 KV" b3="SECT1-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WARINANC" b2="230 KV" b3="TRAN T-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="VFT_ST" b2="230 KV" b3="VFT-WAR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9470</SeqNum>
    <Name>500/230.RedLion.AT50</Name>
    <LastEdit Timestamp="2026-02-20T10:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="233" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="234" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDLION" b2="500 KV" b3="50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="500 KV" b3="502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="500 KV" b3="503" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9480</SeqNum>
    <Name>500/230.RedLion.AT51</Name>
    <LastEdit Timestamp="2026-02-20T10:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="240" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="500 KV" b3="501" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="500 KV" b3="505" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDLION" b2="500 KV" b3="51" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9490</SeqNum>
    <Name>L230.RedLion-Edgemoor.23020 + Edgemoor.HayRd.CC8</Name>
    <LastEdit Timestamp="2026-02-25T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEMOOR" b2="230 KV" b3="EDG-RED" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="13 KV" b3="HAYRD5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="13 KV" b3="HAYRD6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="13 KV" b3="HAYRD7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="18 KV" b3="HAYRD8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="230 KV" b3="L1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDGEMOOR" b2="230 KV" b3="SSLD" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="230 KV" b3="T50" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="230 KV" b3="T60" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="230 KV" b3="T70" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="230 KV" b3="T80" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="242" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="243" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9500</SeqNum>
    <Name>L230.CoxsCorner-Lumberton.S-2245</Name>
    <LastEdit Timestamp="2025-06-05T08:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COXSCORN" b2="230 KV" b3="COX-LUM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COXSCORN" b2="230 KV" b3="SECT2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COXSCORN" b2="230 KV" b3="SECT3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMBERTO" b2="230 KV" b3="1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMBERTO" b2="69 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMBERTO" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMBERTO" b2="69 KV" b3="7-8" />
      <ContingencyEquipment Action="X" Type="XF" b1="LUMBERTO" b2="230 KV" b3="T-220-5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LUMBERTO" b2="230 KV" b3="T12TRANS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9510</SeqNum>
    <Name>230/138.Essex.T220-1 + L138.Essex-ECRRF.C-1355</Name>
    <LastEdit Timestamp="2025-06-02T13:34:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ECRRF" b2="138 KV" b3="ECR-ESS" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ECRRF" b2="13 KV" b3="ECRF#1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ECRRF" b2="138 KV" b3="NO 1GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ECRRF" b2="138 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ECRRF" b2="13 KV" b3="TIECB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ESSEX" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="220-1T" />
      <ContingencyEquipment Action="S" Type="SD" b1="ESSEX" b2="138 KV" b3="H-C1355" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9520</SeqNum>
    <Name>L230.Tabor-WayneJCT-Waneeta.220-28</Name>
    <LastEdit Timestamp="2026-02-25T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TABOR" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TABOR" b2="230 KV" b3="905 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="TABOR" b2="230 KV" b3="TAB-WAY" />
      <ContingencyEquipment Action="X" Type="XF" b1="TABOR" b2="230 KV" b3="TR 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="230 KV" b3="285 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="WAYNEJCT" b2="230 KV" b3="220-28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNEJCT" b2="230 KV" b3="2A CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="WANEETA" b2="230 KV" b3="WAN-WAY8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9560</SeqNum>
    <Name>L230.CedarGrove-JacksonRoad.S-2350</Name>
    <LastEdit Timestamp="2025-05-15T09:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="230 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARGRO" b2="230 KV" b3="CED-JAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PS" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PS" b2="230 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9570</SeqNum>
    <Name>L230.HinchmansAv-JacksonsRd.M-2239</Name>
    <LastEdit Timestamp="2024-10-25T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HINCHMAN" b2="230 KV" b3="HIN-JAC" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HINCHMAN" b2="230 KV" b3="REAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINCHMAN" b2="230 KV" b3="SECT 3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PS" b2="230 KV" b3="2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PS" b2="230 KV" b3="9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9610</SeqNum>
    <Name>L115.Orrtanna-Lincoln</Name>
    <LastEdit Timestamp="2026-02-26T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN" b2="115 KV" b3="96362" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLN" b2="115 KV" b3="LIN-ORRT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORRTANNA" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORRTANNA" b2="115 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9620</SeqNum>
    <Name>L115.Mountain-Gardners.974</Name>
    <LastEdit Timestamp="2026-03-12T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GARDNERS" b2="115 KV" b3="97482" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARDNERS" b2="115 KV" b3="97488" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARDNERS" b2="115 KV" b3="GAR-MOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN ME" b2="115 KV" b3="B97412" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9640</SeqNum>
    <Name>L115.PPGI-Allen.981-1 </Name>
    <LastEdit Timestamp="2026-05-27T07:22:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLEN" b2="115 KV" b3="ALL-PPG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLEN" b2="115 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLEN" b2="115 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PPGI" b2="115 KV" b3="B98122" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9650</SeqNum>
    <Name>L115.PPGI-Mountain.982</Name>
    <LastEdit Timestamp="2026-03-12T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN ME" b2="115 KV" b3="98212" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUN ME" b2="115 KV" b3="MOU-PPG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PPGI" b2="115 KV" b3="B98222" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9660</SeqNum>
    <Name>L115.Hunterstown-TexasEastern-Gardners.991</Name>
    <LastEdit Timestamp="2026-03-12T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GARDNERS" b2="115 KV" b3="B99182" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GARDNERS" b2="115 KV" b3="B99188" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARDNERS" b2="115 KV" b3="GAR-TEX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="115 KV" b3="99192CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="TEXSEAST" b2="115 KV" b3="TEX-HUN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TEXSEAST" b2="115 KV" b3="TEXSEAST" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9670</SeqNum>
    <Name>L115.Lincoln-Straban-Germantown.998</Name>
    <LastEdit Timestamp="2026-02-25T10:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GERMANTO" b2="115 KV" b3="99842" />
      <ContingencyEquipment Action="L" Type="LN" b1="GERMANTO" b2="115 KV" b3="GER-STR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN" b2="115 KV" b3="99862" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLN" b2="115 KV" b3="LIN-STR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINCOLN" b2="115 KV" b3="MOB12_LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STRABAN" b2="115 KV" b3="1 BANK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9680</SeqNum>
    <Name>L115.Hunterstown-Riley</Name>
    <LastEdit Timestamp="2026-01-23T15:38:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="115 KV" b3="96292" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTERST" b2="115 KV" b3="HUN-RILE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RILEY" b2="115 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RILEY" b2="115 KV" b3="B30" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9700</SeqNum>
    <Name>Orrtanna.CT</Name>
    <LastEdit Timestamp="2025-07-23T16:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ORRTANNA" b2="115 KV" b3="3 TX 11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORRTANNA" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORRTANNA" b2="115 KV" b3="B4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ORRTANNA" b2="13 KV" b3="ORRTAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9710</SeqNum>
    <Name>Mountain.CT1</Name>
    <LastEdit Timestamp="2026-02-25T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN ME" b2="13 KV" b3="G112" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOUN ME" b2="13 KV" b3="GEN #1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9720</SeqNum>
    <Name>Mountain.CT2</Name>
    <LastEdit Timestamp="2026-02-25T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN ME" b2="13 KV" b3="G212" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOUN ME" b2="13 KV" b3="GEN #2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9740</SeqNum>
    <Name>230/115.MiddletownJct.T5</Name>
    <LastEdit Timestamp="2024-12-09T15:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="MIDDLJCT" b2="115 KV" b3="5 TX RE" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDDLJCT" b2="230 KV" b3="5T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="115 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B64" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9750</SeqNum>
    <Name>L115.CarlislePike-Gardners.976</Name>
    <LastEdit Timestamp="2024-07-20T07:55:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CARL PN" b2="115 KV" b3="1TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARL PN" b2="115 KV" b3="A34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARL PN" b2="115 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARDNERS" b2="115 KV" b3="B97682" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARL PN" b2="115 KV" b3="CAR-GAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9760</SeqNum>
    <Name>L115.CarlislePike-Roxbury.1049</Name>
    <LastEdit Timestamp="2025-11-25T16:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CARL PN" b2="115 KV" b3="2TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARL PN" b2="115 KV" b3="A11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARL PN" b2="115 KV" b3="B13" />
      <ContingencyEquipment Action="CL" Type="CB" b1="CARL PN" b2="23 KV" b3="BSSCT23" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARL PN" b2="115 KV" b3="CAR-ROX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBURY" b2="115 KV" b3="B31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBURY" b2="115 KV" b3="B32" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9790</SeqNum>
    <Name>L115.Claysburg-SummitWest</Name>
    <LastEdit Timestamp="2025-11-11T14:28:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSBUR" b2="115 KV" b3="B46" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSBUR" b2="115 KV" b3="B47" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYSBUR" b2="115 KV" b3="CLA-SUMM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="115 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="115 KV" b3="B40" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9800</SeqNum>
    <Name>L115.SnakeSpring-Saxton</Name>
    <LastEdit Timestamp="2025-03-17T13:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SAXTON" b2="115 KV" b3="B42" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAXTON" b2="115 KV" b3="SAX-SNA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SNAKESPR" b2="115 KV" b3="1 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SNAKESPR" b2="115 KV" b3="B17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9810</SeqNum>
    <Name>L115.BedfordNorth-SnakeSpring.1064</Name>
    <LastEdit Timestamp="2025-01-27T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD" b2="115 KV" b3="B26" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEDFORD" b2="115 KV" b3="BED-SNA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SNAKESPR" b2="115 KV" b3="2 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SNAKESPR" b2="115 KV" b3="B17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9820</SeqNum>
    <Name>L115.Allegheny-Somerset.1007</Name>
    <LastEdit Timestamp="2025-03-14T10:45:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLEGHEN" b2="115 KV" b3="ALL-PRI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLEGHEN" b2="115 KV" b3="B16" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PRIDE" b2="115 KV" b3="PRIDE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOME PN" b2="115 KV" b3="B28" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRIDE" b2="115 KV" b3="PRI-SOM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9830</SeqNum>
    <Name>L115.Lewistown-Reeds-ShadeGap</Name>
    <LastEdit Timestamp="2025-08-22T12:23:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLAIN" b2="115 KV" b3="#1 TX" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLAIN" b2="115 KV" b3="BLA-REE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="115 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEWISTOW" b2="115 KV" b3="LEW-REE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="115 KV" b3="SHDGPAUX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REEDSGAP" b2="115 KV" b3="1 TX" />
      <ContingencyEquipment Action="L" Type="LN" b1="REEDSGAP" b2="115 KV" b3="REE-REE" />
      <ContingencyEquipment Action="L" Type="LN" b1="REEDSSS" b2="115 KV" b3="REE-SHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHADEGAP" b2="115 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9840</SeqNum>
    <Name>DTX230.Lewistown.T1</Name>
    <LastEdit Timestamp="2025-07-28T12:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B86" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B87" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEWISTOW" b2="230 KV" b3="T1_LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9850</SeqNum>
    <Name>230/115.Lewistown.T3</Name>
    <LastEdit Timestamp="2024-09-25T14:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B83" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="115 KV" b3="B92" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEWISTOW" b2="230 KV" b3="NO3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9860</SeqNum>
    <Name>L115.Mansfield-NilesValley.1095</Name>
    <LastEdit Timestamp="2026-02-20T10:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MANS PN" b2="115 KV" b3="MAN-NIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANS PN" b2="115 KV" b3="NILESVLY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NILESVAL" b2="115 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9870</SeqNum>
    <Name>L115.Hector-Gold-TennGas-Potter</Name>
    <LastEdit Timestamp="2026-02-10T11:35:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GOLD" b2="115 KV" b3="GOL-HEC" />
      <ContingencyEquipment Action="L" Type="LN" b1="TENNGAS" b2="115 KV" b3="GOL-TEN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOLD" b2="115 KV" b3="NO.1 T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HECTOR" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HECTOR" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTER" b2="115 KV" b3="1CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTER" b2="115 KV" b3="2CAP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POTTER" b2="115 KV" b3="BT CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="POTTER" b2="115 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="POTTER" b2="115 KV" b3="CAP2" />
      <ContingencyEquipment Action="X" Type="XF" b1="POTTER" b2="115 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTER" b2="46 KV" b3="T2LCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="POTTER" b2="115 KV" b3="POT-TENN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TENNGAS" b2="115 KV" b3="TENNGAS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9910</SeqNum>
    <Name>L115.Forest-Ridgeway</Name>
    <LastEdit Timestamp="2025-12-26T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOREST" b2="115 KV" b3="B20" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOREST" b2="115 KV" b3="FOR-RID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDG PN" b2="115 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RIDG PN" b2="115 KV" b3="D17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9920</SeqNum>
    <Name>L115.Ridgeway-Whetstone</Name>
    <LastEdit Timestamp="2024-05-15T09:13:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDG PN" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RIDG PN" b2="115 KV" b3="D49" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIDG PN" b2="115 KV" b3="RID-WHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHETSTON" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHETSTON" b2="115 KV" b3="BRCKW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9940</SeqNum>
    <Name>L115.Dubois-RocktonMtn-Shawville.1076</Name>
    <LastEdit Timestamp="2024-10-10T03:58:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUBOIS" b2="34.5 KV" b3="3LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="DUBOIS" b2="115 KV" b3="3TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUBOIS" b2="115 KV" b3="BSSCT115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUBOIS" b2="34.5 KV" b3="BSSCT34" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUBOIS" b2="115 KV" b3="DUB-ROC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DUBOIS" b2="34.5 KV" b3="UNVIA_SP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKTONM" b2="115 KV" b3="NO.1 T" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKTONM" b2="115 KV" b3="ROC-SHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWVILL" b2="115 KV" b3="B14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9950</SeqNum>
    <Name>Shawville.U1</Name>
    <LastEdit Timestamp="2025-04-29T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWVILL" b2="230 KV" b3="B1017" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWVILL" b2="115 KV" b3="B1019" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWVILL" b2="115 KV" b3="B1021" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWVILL" b2="230 KV" b3="BNK 1A-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWVILL" b2="115 KV" b3="BNK 1A-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWVILL" b2="18 KV" b3="BNK 1A-T" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWVILL" b2="115 KV" b3="BNK 1B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SHAWVILL" b2="18 KV" b3="UNIT 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9960</SeqNum>
    <Name>Shawville.U2</Name>
    <LastEdit Timestamp="2025-04-29T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWVILL" b2="230 KV" b3="B2017" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWVILL" b2="115 KV" b3="B2019" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWVILL" b2="115 KV" b3="B2021" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWVILL" b2="230 KV" b3="BNK 2A-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWVILL" b2="115 KV" b3="BNK 2A-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWVILL" b2="18 KV" b3="BNK 2A-T" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWVILL" b2="115 KV" b3="BNK 2B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SHAWVILL" b2="18 KV" b3="UNIT 2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9980</SeqNum>
    <Name>L115.Glory-Garman.992</Name>
    <LastEdit Timestamp="2025-07-31T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GARMAN" b2="115 KV" b3="1 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARMAN" b2="115 KV" b3="B11" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARMAN" b2="115 KV" b3="GAR-GLO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLORY" b2="115 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLORY" b2="115 KV" b3="B54" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>9990</SeqNum>
    <Name>L115.Shawville-Philipsburg.1079</Name>
    <LastEdit Timestamp="2026-03-03T10:55:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PHILIPSB" b2="115 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PHILIPSB" b2="115 KV" b3="DUMF2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PHILIPSB" b2="115 KV" b3="PHI-SHA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PHILIPSB" b2="115 KV" b3="TWO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHILIPSB" b2="115 KV" b3="UNSH_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWVILL" b2="115 KV" b3="B28" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10000</SeqNum>
    <Name>115/46.TyroneNorth.BK1</Name>
    <LastEdit Timestamp="2024-11-21T14:31:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TYRONEN" b2="115 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYRONEN" b2="115 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYRONEN" b2="46 KV" b3="B6" />
      <ContingencyEquipment Action="X" Type="XF" b1="TYRONEN" b2="115 KV" b3="BK_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10010</SeqNum>
    <Name>L115.ThirtyFirst-SummitWest</Name>
    <LastEdit Timestamp="2026-02-10T10:30:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="115 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="115 KV" b3="B60" />
      <ContingencyEquipment Action="L" Type="LN" b1="THIRTYST" b2="115 KV" b3="THI-SUMW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THIRTYST" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THIRTYST" b2="115 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10020</SeqNum>
    <Name>L115.CorryEast-Warren</Name>
    <LastEdit Timestamp="2025-05-13T10:02:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRYE" b2="115 KV" b3="A5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRYE" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRYE" b2="34.5 KV" b3="B2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CORRYE" b2="115 KV" b3="BK3" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORRYE" b2="115 KV" b3="COR-WAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="115 KV" b3="B29" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10050</SeqNum>
    <Name>L230.Bushkill-Shawnee + 230/34.Shawnee.T4</Name>
    <LastEdit Timestamp="2024-10-23T13:19:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUSHKILL" b2="230 KV" b3="SHAWNCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWNEE" b2="230 KV" b3="4 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEE" b2="34 KV" b3="4B32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEE" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUSHKILL" b2="230 KV" b3="BUS-SHA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10060</SeqNum>
    <Name>L230.SouthManheim-BrunnerIsland + SouthManheim.T3</Name>
    <LastEdit Timestamp="2026-01-07T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNNERI" b2="230 KV" b3="BRU-SMA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="SMAN E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="SMAN W" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMANHEIM" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMANHEIM" b2="230 KV" b3="LINE_MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMANHEIM" b2="69 KV" b3="TRAN_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10120</SeqNum>
    <Name>L230.Elko-SquabHollow</Name>
    <LastEdit Timestamp="2026-02-20T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELKO" b2="230 KV" b3="ELK-SQU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELKO" b2="230 KV" b3="FOREST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SQUABHOL" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SQUABHOL" b2="230 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10160</SeqNum>
    <Name>L230.ErieEast-SouthRipley [NYISO]</Name>
    <LastEdit Timestamp="2024-11-08T12:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEE" b2="230 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEE" b2="230 KV" b3="B8" />
      <ContingencyEquipment Action="S" Type="SD" b1="ERIEE" b2="230 KV" b3="SEREACT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SRIPLEY" b2="230 KV" b3="100" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERIEE" b2="230 KV" b3="ERI-SRI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10260</SeqNum>
    <Name>230/115.EastTowanda.T4</Name>
    <LastEdit Timestamp="2025-04-22T11:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ETOWANDA" b2="230 KV" b3="4 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B111" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="230 KV" b3="B29 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10310</SeqNum>
    <Name>230/115.EastTowanda.T3</Name>
    <LastEdit Timestamp="2025-03-28T15:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ETOWANDA" b2="230 KV" b3="3 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B116" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="230 KV" b3="B39" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10330</SeqNum>
    <Name>L69.UpperSaddleRiver-SouthMahwah.652</Name>
    <LastEdit Timestamp="2026-02-25T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="69 KV" b3="652-52-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SMAWA" b2="69 KV" b3="SMA-UPP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="UPPERSAD" b2="69 KV" b3="652-49-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10340</SeqNum>
    <Name>L500.HopeCreek-Salem.5037</Name>
    <LastEdit Timestamp="2026-02-10T11:49:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="SECT2-6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOPECREE" b2="500 KV" b3="SLP_2_NC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOPECREE" b2="500 KV" b3="SLP_4_NC" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPECREE" b2="500 KV" b3="HOP-SAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10350</SeqNum>
    <Name>L500.HopeCreek-NewFreedom.5023</Name>
    <LastEdit Timestamp="2026-02-20T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="SECT1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="SECT5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPECREE" b2="500 KV" b3="HOP-NEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10360</SeqNum>
    <Name>HopeCreek.U1</Name>
    <LastEdit Timestamp="2026-02-10T11:59:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOPECREE" b2="25 KV" b3="AUX1LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOPECREE" b2="500 KV" b3="NO 1GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="SECT2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="SECT5-6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HOPECREE" b2="25 KV" b3="UNIT 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10370</SeqNum>
    <Name>L500.HopeCreek-RedLion.5015</Name>
    <LastEdit Timestamp="2024-12-30T14:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="SECT1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="SECT3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="500 KV" b3="503" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="500 KV" b3="505" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPECREE" b2="500 KV" b3="HOP-RED" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10410</SeqNum>
    <Name>L230.SteelCity-Quarry.1</Name>
    <LastEdit Timestamp="2026-02-20T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="QUARRY" b2="230 KV" b3="QUA-STE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="230 KV" b3="STCI1_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="230 KV" b3="STCI1_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELCTY" b2="230 KV" b3="QUAR1_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELCTY" b2="230 KV" b3="QUAR1_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10630</SeqNum>
    <Name>L500.Deans-EastWindsor.5022</Name>
    <LastEdit Timestamp="2025-01-15T18:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="500 KV" b3="SECT 2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="500 KV" b3="SECT 5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="500 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="500 KV" b3="B16" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEANS" b2="500 KV" b3="DEA-EWI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10760</SeqNum>
    <Name>L230.Burtonsville-MetzerottRoad-Takoma.23040/23018</Name>
    <LastEdit Timestamp="2026-05-14T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="23040B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURTONSV" b2="230 KV" b3="BUR-MET0" />
      <ContingencyEquipment Action="X" Type="XF" b1="METZTAP" b2="230 KV" b3="163-1T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METZTAP" b2="69 KV" b3="1TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METZTAP" b2="69 KV" b3="1TS2B" />
      <ContingencyEquipment Action="L" Type="LN" b1="METZTAP" b2="230 KV" b3="MET-TAK8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="6A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="6B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10770</SeqNum>
    <Name>L230.Burtonsville-MetzerottRoad-Takoma.23041/23019</Name>
    <LastEdit Timestamp="2026-01-27T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="23041-B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURTONSV" b2="230 KV" b3="BUR-MET8" />
      <ContingencyEquipment Action="X" Type="XF" b1="METZTAP" b2="230 KV" b3="163-4T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METZTAP" b2="69 KV" b3="4TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METZTAP" b2="69 KV" b3="4TS4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="3A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="3B" />
      <ContingencyEquipment Action="L" Type="LN" b1="METZTAP" b2="230 KV" b3="MET-TAK9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10780</SeqNum>
    <Name>L230.Burtonsville-MetzerottRoad-Takoma.23046/23020</Name>
    <LastEdit Timestamp="2024-06-13T08:40:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="23046B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURTONSV" b2="230 KV" b3="BUR-MET6" />
      <ContingencyEquipment Action="X" Type="XF" b1="METZTAP" b2="230 KV" b3="163-3T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METZTAP" b2="69 KV" b3="3TS3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METZTAP" b2="69 KV" b3="3TS4B" />
      <ContingencyEquipment Action="L" Type="LN" b1="METZTAP" b2="230 KV" b3="MET-TAK0" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="2A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10790</SeqNum>
    <Name>L230.Burtonsville-MetzerottRoad-Takoma.23047/23021</Name>
    <LastEdit Timestamp="2025-11-18T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="23047B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURTONSV" b2="230 KV" b3="BUR-MET7" />
      <ContingencyEquipment Action="X" Type="XF" b1="METZTAP" b2="230 KV" b3="163-2T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METZTAP" b2="69 KV" b3="2TS2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METZTAP" b2="69 KV" b3="2TS3B" />
      <ContingencyEquipment Action="L" Type="LN" b1="METZTAP" b2="230 KV" b3="MET-TAK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="5A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="5B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10800</SeqNum>
    <Name>L230.OakGrove-Ritchie.23059 + 230/69.Ritchie.T3</Name>
    <LastEdit Timestamp="2026-02-25T10:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="4AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="4CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKGROVE" b2="230 KV" b3="OAK-RIT9" />
      <ContingencyEquipment Action="X" Type="XF" b1="RITCHIE" b2="230 KV" b3="123-3T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="230 KV" b3="23003B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="230 KV" b3="23016B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="69 KV" b3="3TS3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="69 KV" b3="3TS4B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10810</SeqNum>
    <Name>L230.OakGrove-Ritchie.23060 + 230/69.Ritchie.T2</Name>
    <LastEdit Timestamp="2026-02-25T10:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="2AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="2BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKGROVE" b2="230 KV" b3="OAK-RIT0" />
      <ContingencyEquipment Action="X" Type="XF" b1="RITCHIE" b2="230 KV" b3="123-2T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="230 KV" b3="23004B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="230 KV" b3="23051B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="69 KV" b3="2TS2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="69 KV" b3="2TS3B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10840</SeqNum>
    <Name>L230.Benning-Ritchie.23003</Name>
    <LastEdit Timestamp="2026-02-20T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="2BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="2CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENNING" b2="230 KV" b3="BEN-RIT3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="230 KV" b3="23003B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10850</SeqNum>
    <Name>L230.Bowie-OakGrv-Aquasco-ChalkPt-Holl.23153/23063</Name>
    <LastEdit Timestamp="2026-03-31T15:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUASCO" b2="230 KV" b3="1110" />
      <ContingencyEquipment Action="L" Type="LN" b1="AQUASCO" b2="230 KV" b3="AQU-CHA2" />
      <ContingencyEquipment Action="L" Type="LN" b1="AQUASCO" b2="230 KV" b3="AQU-OAKG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="230 KV" b3="23054LB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOWIE" b2="230 KV" b3="BOW-OAK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="4AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="4BB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10860</SeqNum>
    <Name>L230.Bowie-ChalkPoint.23065</Name>
    <LastEdit Timestamp="2025-12-26T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="230 KV" b3="23065B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOWIE" b2="230 KV" b3="BOW-CHAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="1AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="1BB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10870</SeqNum>
    <Name>L230.WaughChapel-JerichoPark-Bowie.2341</Name>
    <LastEdit Timestamp="2025-10-06T11:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="230 KV" b3="2341B" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23016_50" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23016_51" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23025_50" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23025_51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JERICHOP" b2="230 KV" b3="230-2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JERICHOP" b2="230 KV" b3="2341-51" />
      <ContingencyEquipment Action="S" Type="SD" b1="JERICHOP" b2="230 KV" b3="2341SD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOWIE" b2="230 KV" b3="BOW-JER1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JERICHOP" b2="230 KV" b3="JER-WAU1" />
      <ContingencyEquipment Action="CL" Type="CB" b1="JERICHOP" b2="230 KV" b3="TIECB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="23411BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="23414BUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10880</SeqNum>
    <Name>L230.OakGrove-Ritchie.23058 + 230/69.Ritchie.T1</Name>
    <LastEdit Timestamp="2026-02-20T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="6AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="6BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="RITCHIE" b2="230 KV" b3="OAK-RIT8" />
      <ContingencyEquipment Action="X" Type="XF" b1="RITCHIE" b2="230 KV" b3="123-1T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="69 KV" b3="1TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="69 KV" b3="1TS2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="230 KV" b3="23002B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10910</SeqNum>
    <Name>230/115.ErieSouth.T6</Name>
    <LastEdit Timestamp="2025-12-22T21:44:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ERIES" b2="230 KV" b3="3 TX 3" />
      <ContingencyEquipment Action="X" Type="XF" b1="ERIES" b2="230 KV" b3="6 TX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ERIES" b2="230 KV" b3="7 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="115 KV" b3="B153" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="230 KV" b3="B27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="230 KV" b3="CAPWESTC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="230 KV" b3="NO5TX230" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ERIES" b2="230 KV" b3="WEST" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>10990</SeqNum>
    <Name>L115.EastTowanda-NorthMeshoppen.1057</Name>
    <LastEdit Timestamp="2024-11-07T11:42:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B108" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B109" />
      <ContingencyEquipment Action="L" Type="LN" b1="ETOWANDA" b2="115 KV" b3="ETO-NME" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="115 KV" b3="B101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="115 KV" b3="B102" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11070</SeqNum>
    <Name>L500.MeadowBrook-FrontRoyal.580</Name>
    <LastEdit Timestamp="2025-05-23T14:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTROY" b2="500 KV" b3="541T580" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTROY" b2="500 KV" b3="580T592" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRONTROY" b2="500 KV" b3="FRO-MEAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="500 KV" b3="MDL09" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="500 KV" b3="MDL10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11080</SeqNum>
    <Name>L500.BlackOak-Hatfield.542</Name>
    <LastEdit Timestamp="2026-04-20T15:28:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKOAK" b2="500 KV" b3="BOL1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKOAK" b2="500 KV" b3="BOL2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATFIELD" b2="500 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATFIELD" b2="500 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKOAK" b2="500 KV" b3="BLA-HAT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11090</SeqNum>
    <Name>L500.Cabot-Cranberry</Name>
    <LastEdit Timestamp="2025-06-03T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRANBERY" b2="500 KV" b3="CAB-CRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="500 KV" b3="CB 01" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="500 KV" b3="CB 02" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="500 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="500 KV" b3="B6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11100</SeqNum>
    <Name>L69.Richmond-Amtrak.6662</Name>
    <LastEdit Timestamp="2025-01-13T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMTRAK" b2="69 KV" b3="22 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMTRAK" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMTRAK" b2="69 KV" b3="LOAD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="69 KV" b3="20 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="69 KV" b3="60 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMTRAK" b2="69 KV" b3="AMT-RIC2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11110</SeqNum>
    <Name>L69.Richmond-Tacony.6605</Name>
    <LastEdit Timestamp="2026-02-25T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="69 KV" b3="120 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="69 KV" b3="130 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="RICH PE" b2="69 KV" b3="RIC-TAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TACONY" b2="69 KV" b3="55 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11120</SeqNum>
    <Name>L69.Holmesburg-Tacony.6606</Name>
    <LastEdit Timestamp="2026-02-25T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLMESBU" b2="69 KV" b3="065 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLMESBU" b2="69 KV" b3="HOL-TAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TACONY" b2="69 KV" b3="65 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11130</SeqNum>
    <Name>L69.Richmond-Westmoreland.6603</Name>
    <LastEdit Timestamp="2025-01-13T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="69 KV" b3="140 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="69 KV" b3="150 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="RICH PE" b2="69 KV" b3="RIC-WMO3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="69 KV" b3="20 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="69 KV" b3="30 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11140</SeqNum>
    <Name>L69.Master-Westmoreland.6626</Name>
    <LastEdit Timestamp="2026-02-25T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MASTER" b2="69 KV" b3="265 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="MASTER" b2="69 KV" b3="MAS-WMO6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="69 KV" b3="50 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="69 KV" b3="60 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11150</SeqNum>
    <Name>L69.IslandRoad-SharonHill.6645</Name>
    <LastEdit Timestamp="2026-02-25T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="69 KV" b3="6645 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ISLANDRD" b2="69 KV" b3="ISL-SHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARONHI" b2="69 KV" b3="6645 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11170</SeqNum>
    <Name>L69.Chester-Chichester.6652</Name>
    <LastEdit Timestamp="2026-02-25T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="69 KV" b3="10 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="69 KV" b3="60 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTER" b2="69 KV" b3="CHE-CHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="69 KV" b3="525" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11180</SeqNum>
    <Name>L69.Chester-ScottPaperTap.6659</Name>
    <LastEdit Timestamp="2026-02-26T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="69 KV" b3="20 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="69 KV" b3="50 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTER" b2="69 KV" b3="CHE-SCO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOTTPAP" b2="69 KV" b3="595 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11190</SeqNum>
    <Name>69/13.Angora.T1</Name>
    <LastEdit Timestamp="2026-02-25T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGORA" b2="69 KV" b3="1TRHS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGORA" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ANGORA" b2="69 KV" b3="ANG 1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11200</SeqNum>
    <Name>69/13.Angora.T2</Name>
    <LastEdit Timestamp="2026-02-25T10:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGORA" b2="69 KV" b3="2TRHS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGORA" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ANGORA" b2="69 KV" b3="ANG 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11230</SeqNum>
    <Name>230/35.Bradford.T1</Name>
    <LastEdit Timestamp="2026-02-25T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="35 KV" b3="115 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="230 KV" b3="15 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRADFORD" b2="230 KV" b3="BRAD1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11240</SeqNum>
    <Name>230/35.Bradford.T2</Name>
    <LastEdit Timestamp="2026-02-25T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="35 KV" b3="225-CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="230 KV" b3="25 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRADFORD" b2="230 KV" b3="BRAD2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11250</SeqNum>
    <Name>230/34.Buckingham.2TR</Name>
    <LastEdit Timestamp="2025-09-05T10:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKINGH" b2="35 KV" b3="20" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUCKINGH" b2="230 KV" b3="25 CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUCKINGH" b2="230 KV" b3="BUCK2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11260</SeqNum>
    <Name>230/35.Buckingham.3TR</Name>
    <LastEdit Timestamp="2025-09-05T10:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKINGH" b2="35 KV" b3="30" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUCKINGH" b2="230 KV" b3="35 CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUCKINGH" b2="230 KV" b3="BUCK3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11270</SeqNum>
    <Name>138/35.Byberry.T2</Name>
    <LastEdit Timestamp="2026-02-25T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BYBERRY" b2="138 KV" b3="100 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BYBERRY" b2="35 KV" b3="90 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BYBERRY" b2="138 KV" b3="BYB 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11280</SeqNum>
    <Name>35/13.Chester.T38</Name>
    <LastEdit Timestamp="2026-02-25T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="13 KV" b3="125" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="35 KV" b3="385 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTER" b2="35 KV" b3="CHE38TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11290</SeqNum>
    <Name>69/35.Chester.T48</Name>
    <LastEdit Timestamp="2026-02-26T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="35 KV" b3="395 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="69 KV" b3="485 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTER" b2="69 KV" b3="CHE48TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11300</SeqNum>
    <Name>69/35.Chester.T52</Name>
    <LastEdit Timestamp="2026-02-26T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="13 KV" b3="165" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="69 KV" b3="50 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="69 KV" b3="60 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTER" b2="69 KV" b3="CHE52TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11310</SeqNum>
    <Name>138/69.Chichester.T7</Name>
    <LastEdit Timestamp="2026-02-25T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="69 KV" b3="175 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="138 KV" b3="775 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHICHEST" b2="138 KV" b3="CHI 7TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11320</SeqNum>
    <Name>138/69.Chichester.T8</Name>
    <LastEdit Timestamp="2026-02-25T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="69 KV" b3="285 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="138 KV" b3="885 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHICHEST" b2="138 KV" b3="CHI 8TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11340</SeqNum>
    <Name>230/13.Croydon.TX1</Name>
    <LastEdit Timestamp="2025-09-05T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="230 KV" b3="115 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="230 KV" b3="135 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROYDON" b2="230 KV" b3="CROY 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11350</SeqNum>
    <Name>230/13.Croydon.TX3</Name>
    <LastEdit Timestamp="2025-09-05T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="230 KV" b3="315 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="230 KV" b3="335 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROYDON" b2="230 KV" b3="CROY 3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11360</SeqNum>
    <Name>L230.Concord-Foulk.220-67 + 230/13.Foulk.T1</Name>
    <LastEdit Timestamp="2026-02-25T10:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC PE" b2="35 KV" b3="225 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC PE" b2="230 KV" b3="565 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONC PE" b2="230 KV" b3="CON 2TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONC PE" b2="230 KV" b3="CON-FOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOULK" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOULK" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FOULK" b2="230 KV" b3="FOU 1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11370</SeqNum>
    <Name>230/13.Foulk.2TR</Name>
    <LastEdit Timestamp="2025-09-05T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FOULK" b2="230 KV" b3="25 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOULK" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FOULK" b2="230 KV" b3="FOU 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11380</SeqNum>
    <Name>230/13.GraysFerry.T2</Name>
    <LastEdit Timestamp="2026-02-25T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="25 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRAYSFER" b2="230 KV" b3="2TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="13 KV" b3="2TRLS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11390</SeqNum>
    <Name>230/13.Jenkintown.T12</Name>
    <LastEdit Timestamp="2026-02-25T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINTO" b2="13 KV" b3="12TRLSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINTO" b2="230 KV" b3="240" />
      <ContingencyEquipment Action="X" Type="XF" b1="JENKINTO" b2="230 KV" b3="JENK12T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11400</SeqNum>
    <Name>230/69.IslandRoad.T6</Name>
    <LastEdit Timestamp="2026-02-25T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="69 KV" b3="65 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="230 KV" b3="665 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ISLANDRD" b2="230 KV" b3="IR 6TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11410</SeqNum>
    <Name>138/35.Llanerch.T5</Name>
    <LastEdit Timestamp="2026-03-06T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="35 KV" b3="515 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="138 KV" b3="555 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LLANERCH" b2="138 KV" b3="LAN 5TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11420</SeqNum>
    <Name>138/35.Llanerch.T6</Name>
    <LastEdit Timestamp="2026-03-06T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="35 KV" b3="635 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="138 KV" b3="665 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LLANERCH" b2="138 KV" b3="LAN 6TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11430</SeqNum>
    <Name>138/35.LLanerch.T11</Name>
    <LastEdit Timestamp="2026-03-06T09:45:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LLANERCH" b2="13 KV" b3="11BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="13 KV" b3="12-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="138 KV" b3="155 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LLANERCH" b2="138 KV" b3="LAN 11TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11460</SeqNum>
    <Name>69/13.MarcusHook.T3 </Name>
    <LastEdit Timestamp="2024-08-19T13:42:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARCUSHO" b2="69 KV" b3="335_CB_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARCUSHO" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARCUSHO" b2="69 KV" b3="MAR 3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11470</SeqNum>
    <Name>69/13.MarcusHook.T4 </Name>
    <LastEdit Timestamp="2024-08-19T13:43:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARCUSHO" b2="69 KV" b3="445_CB_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARCUSHO" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARCUSHO" b2="69 KV" b3="MAR 4TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11500</SeqNum>
    <Name>230/35.Newlinville.T1</Name>
    <LastEdit Timestamp="2026-03-06T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLINVI" b2="230 KV" b3="220 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLINVI" b2="35 KV" b3="40 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWLINVI" b2="230 KV" b3="NEW 1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11510</SeqNum>
    <Name>230/138.PlymouthMeeting.T6</Name>
    <LastEdit Timestamp="2026-02-25T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="230 KV" b3="265 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="138 KV" b3="865 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLYMOUTH" b2="230 KV" b3="PLY 6TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11540</SeqNum>
    <Name>69/13.Schuylkill.T5 </Name>
    <LastEdit Timestamp="2026-03-06T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="330 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="340 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="13 KV" b3="5TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCHUYLKI" b2="69 KV" b3="SCH 5TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11580</SeqNum>
    <Name>230/13.Wanneta.T1 </Name>
    <LastEdit Timestamp="2026-03-06T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="230 KV" b3="145 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WANEETA" b2="230 KV" b3="WAN 1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11590</SeqNum>
    <Name>230/13.Waneeta.T3 </Name>
    <LastEdit Timestamp="2026-03-06T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="230 KV" b3="365 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WANEETA" b2="230 KV" b3="WAN 3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11620</SeqNum>
    <Name>230/35.Warrington.TR1</Name>
    <LastEdit Timestamp="2026-02-26T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINGT" b2="35 KV" b3="115 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINGT" b2="230 KV" b3="195 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINGT" b2="230 KV" b3="875 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WARRINGT" b2="230 KV" b3="WAR 1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11630</SeqNum>
    <Name>230/35.Warrington.WAR3TR</Name>
    <LastEdit Timestamp="2025-06-05T08:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="WARRINGT" b2="230 KV" b3="230CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINGT" b2="35 KV" b3="315 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINGT" b2="230 KV" b3="585 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINGT" b2="230 KV" b3="815" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINGT" b2="230 KV" b3="875 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WARRINGT" b2="230 KV" b3="WAR 3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11650</SeqNum>
    <Name>230/13.Westmoreland.12TR</Name>
    <LastEdit Timestamp="2025-12-26T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WMORELAN" b2="230 KV" b3="12TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="13 KV" b3="12TRLSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="230 KV" b3="705 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="230 KV" b3="905 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11670</SeqNum>
    <Name>69/35.Whitemarsh.8TR</Name>
    <LastEdit Timestamp="2025-11-18T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEMAR" b2="69 KV" b3="185 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEMAR" b2="35 KV" b3="20 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHITEMAR" b2="69 KV" b3="WHIT8TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11680</SeqNum>
    <Name>69/35.Woodlyn.2TR</Name>
    <LastEdit Timestamp="2026-02-26T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODLYN" b2="35 KV" b3="25 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODLYN" b2="69 KV" b3="45 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODLYN" b2="69 KV" b3="WOD 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11690</SeqNum>
    <Name>Emilie.230.CapEML8-1</Name>
    <LastEdit Timestamp="2026-02-26T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="230 KV" b3="815 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="EMILIE" b2="230 KV" b3="EML 8-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11700</SeqNum>
    <Name>GraysFerry.230.Cap1</Name>
    <LastEdit Timestamp="2026-03-26T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="GRAYSFER" b2="230 KV" b3="8-1_CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="815 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11710</SeqNum>
    <Name>GraysFerry.230.Cap2</Name>
    <LastEdit Timestamp="2026-03-26T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="GRAYSFER" b2="230 KV" b3="8-2_CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="825CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11720</SeqNum>
    <Name>Limerick.500.CapLI3-1</Name>
    <LastEdit Timestamp="2026-02-27T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="500 KV" b3="345 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="500 KV" b3="355 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LIMERICK" b2="500 KV" b3="LI 3-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11730</SeqNum>
    <Name>PlymouthMeeting.230.CapPL1-6</Name>
    <LastEdit Timestamp="2026-02-27T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="230 KV" b3="165 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PLYMOUTH" b2="230 KV" b3="PL 1-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11740</SeqNum>
    <Name>Waneeta.230.CapWA2-1</Name>
    <LastEdit Timestamp="2026-02-27T15:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="230 KV" b3="205 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WANEETA" b2="230 KV" b3="WA 2-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11750</SeqNum>
    <Name>Whitpain.230.2-4Cap</Name>
    <LastEdit Timestamp="2026-04-14T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="WHITPAIN" b2="230 KV" b3="2-4_CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="230 KV" b3="245 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11760</SeqNum>
    <Name>Whitpain.230.2-5Cap</Name>
    <LastEdit Timestamp="2026-04-14T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="WHITPAIN" b2="230 KV" b3="2-5_CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="230 KV" b3="255 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11770</SeqNum>
    <Name>Chester.CT7</Name>
    <LastEdit Timestamp="2026-02-26T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="13 KV" b3="7 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESTER" b2="13 KV" b3="UNIT 7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11780</SeqNum>
    <Name>Chester.CT8</Name>
    <LastEdit Timestamp="2026-02-26T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="13 KV" b3="8 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESTER" b2="13 KV" b3="UNIT 8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11790</SeqNum>
    <Name>Chester.CT9</Name>
    <LastEdit Timestamp="2026-02-26T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="13 KV" b3="9 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESTER" b2="13 KV" b3="UNIT 9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11800</SeqNum>
    <Name>Eddystone.CT10</Name>
    <LastEdit Timestamp="2026-02-26T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="138 KV" b3="105 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDDYSTON" b2="138 KV" b3="EDD 10A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDDYSTON" b2="13 KV" b3="UNIT10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11810</SeqNum>
    <Name>Eddystone.CT20</Name>
    <LastEdit Timestamp="2026-02-26T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="138 KV" b3="205 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDDYSTON" b2="138 KV" b3="EDDY20A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDDYSTON" b2="13 KV" b3="UNIT20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11820</SeqNum>
    <Name>L230.Elmwood-GraysFerry.220-37</Name>
    <LastEdit Timestamp="2026-02-26T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ELMWOOD" b2="230 KV" b3="6TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMWOOD" b2="13 KV" b3="6TRLS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMWOOD" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMWOOD" b2="230 KV" b3="ELM-GRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="375 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="395 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRAYSFER" b2="230 KV" b3="3TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="13 KV" b3="3TRLS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11830</SeqNum>
    <Name>L230.Elmwood-MacDade.220-40</Name>
    <LastEdit Timestamp="2026-02-26T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ELMWOOD" b2="230 KV" b3="4TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMWOOD" b2="13 KV" b3="4TRLS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMWOOD" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMWOOD" b2="230 KV" b3="ELM-MAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACDADE" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACDADE" b2="230 KV" b3="805 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MACDADE" b2="230 KV" b3="MCDADE3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11840</SeqNum>
    <Name>L230.Printz-Ridley-Morton-MacDade.220-46</Name>
    <LastEdit Timestamp="2024-10-23T08:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MACDADE" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACDADE" b2="230 KV" b3="905 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="MACDADE" b2="230 KV" b3="MAC-RID" />
      <ContingencyEquipment Action="X" Type="XF" b1="MACDADE" b2="230 KV" b3="MCDADE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORTON" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORTON" b2="230 KV" b3="565 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORTON" b2="230 KV" b3="MOR-RID" />
      <ContingencyEquipment Action="X" Type="XF" b1="MORTON" b2="230 KV" b3="MORTON2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINTZ" b2="230 KV" b3="115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINTZ" b2="230 KV" b3="125" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRINTZ" b2="230 KV" b3="PRI-RID" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11850</SeqNum>
    <Name>L230.Eddystone-Printz.220-78</Name>
    <LastEdit Timestamp="2026-03-12T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDDYSTON" b2="230 KV" b3="EDD-PRI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINTZ" b2="230 KV" b3="225" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINTZ" b2="230 KV" b3="315" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11860</SeqNum>
    <Name>Printz.Liberty.GTG2</Name>
    <LastEdit Timestamp="2025-12-01T13:41:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PRINTZ" b2="230 KV" b3="1EY_TF-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINTZ" b2="230 KV" b3="215" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINTZ" b2="230 KV" b3="315" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINTZ" b2="18 KV" b3="DUM B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PRINTZ" b2="18 KV" b3="GTG2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PRINTZ" b2="18 KV" b3="SSLOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11870</SeqNum>
    <Name>Printz.Liberty.GTG1</Name>
    <LastEdit Timestamp="2025-12-01T13:40:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINTZ" b2="230 KV" b3="125" />
      <ContingencyEquipment Action="X" Type="XF" b1="PRINTZ" b2="230 KV" b3="1EY_TF-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINTZ" b2="230 KV" b3="225" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINTZ" b2="18 KV" b3="DUM A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PRINTZ" b2="18 KV" b3="GTG1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PRINTZ" b2="18 KV" b3="SSLOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11880</SeqNum>
    <Name>Printz.Liberty.STG</Name>
    <LastEdit Timestamp="2025-11-26T11:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINTZ" b2="230 KV" b3="115" />
      <ContingencyEquipment Action="X" Type="XF" b1="PRINTZ" b2="230 KV" b3="1EY_TF-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINTZ" b2="230 KV" b3="215" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINTZ" b2="18 KV" b3="DUM C" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PRINTZ" b2="18 KV" b3="STG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11890</SeqNum>
    <Name>L230.Emilie-Eddington-Croydon.220-55</Name>
    <LastEdit Timestamp="2026-02-26T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="230 KV" b3="235 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="230 KV" b3="335 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROYDON" b2="230 KV" b3="CRO-EDD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDINGTO" b2="230 KV" b3="125 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDINGTO" b2="13 KV" b3="6TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDDINGTO" b2="230 KV" b3="EDNG6TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDDINGTO" b2="230 KV" b3="EDD-EDD" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDDINTAP" b2="230 KV" b3="EDD-EMI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="230 KV" b3="555 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="35 KV" b3="80 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="EMILIE" b2="230 KV" b3="EMIL5TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11910</SeqNum>
    <Name>L230.IslandRoad-Penrose</Name>
    <LastEdit Timestamp="2026-02-27T15:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="230 KV" b3="235 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="69 KV" b3="65 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="230 KV" b3="665 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="13 KV" b3="8TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ISLANDRD" b2="230 KV" b3="IR 6TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="ISLANDRD" b2="230 KV" b3="IR 8TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="ISLANDRD" b2="230 KV" b3="ISL-PEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENROSE" b2="230 KV" b3="345" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENROSE" b2="230 KV" b3="745" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11920</SeqNum>
    <Name>L230.GraysFerry-GraysCC.220-76 + GraysFerry.CC</Name>
    <LastEdit Timestamp="2026-02-27T15:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="GRAYFR_1" b2="13 KV" b3="1 CT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRAYFR_1" b2="13 KV" b3="1 GEN" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRAYFR_1" b2="230 KV" b3="1TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYFR_1" b2="230 KV" b3="22076CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYFR_1" b2="230 KV" b3="GRA-GRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYFR_1" b2="13 KV" b3="XF1 LS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="765 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11930</SeqNum>
    <Name>L138.Montco-PlymouthMeeting.130-34 + Montco.Unit</Name>
    <LastEdit Timestamp="2026-02-26T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTCO" b2="138 KV" b3="1TRHS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTCO" b2="13 KV" b3="LOAD CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MONTCO" b2="138 KV" b3="MNT 1TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONTCO" b2="138 KV" b3="MON-PLY" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MONTCO" b2="13 KV" b3="MONTCO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="138 KV" b3="345 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11940</SeqNum>
    <Name>L138.BrynMawr-PlymouthMeeting.130-35</Name>
    <LastEdit Timestamp="2026-02-26T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRYNMAWR" b2="138 KV" b3="100 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRYNMAWR" b2="35 KV" b3="160 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRYNMAWR" b2="138 KV" b3="19TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRYNMAWR" b2="13 KV" b3="19TRLS" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRYNMAWR" b2="138 KV" b3="BRY-PLY" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRYNMAWR" b2="138 KV" b3="BRYNMR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="138 KV" b3="355 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11950</SeqNum>
    <Name>L138.BrynMawr-Llanerch.130-36</Name>
    <LastEdit Timestamp="2025-09-05T11:57:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRYNMAWR" b2="138 KV" b3="110 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRYNMAWR" b2="35 KV" b3="130 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRYNMAWR" b2="138 KV" b3="20TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRYNMAWR" b2="13 KV" b3="20TRLS" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRYNMAWR" b2="138 KV" b3="BRY-LLA1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRYNMAWR" b2="138 KV" b3="BRYNMR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="13 KV" b3="12-11" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LLANERCH" b2="13 KV" b3="12BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="13 KV" b3="13-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="138 KV" b3="365 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LLANERCH" b2="138 KV" b3="LAN 12TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11960</SeqNum>
    <Name>L138.Eddystone-Woodlyn.130-41 + 138/69.Woodlyn.4TR</Name>
    <LastEdit Timestamp="2026-02-26T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="138 KV" b3="415 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDDYSTON" b2="138 KV" b3="EDD-WOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODLYN" b2="69 KV" b3="45 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODLYN" b2="138 KV" b3="WOD 4TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11970</SeqNum>
    <Name>L138.Eddystone-Llanerch.130-42</Name>
    <LastEdit Timestamp="2024-12-06T10:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="138 KV" b3="255" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDDYSTON" b2="138 KV" b3="50XFMR" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDDYSTON" b2="138 KV" b3="EDD-LLA2" />
      <ContingencyEquipment Action="S" Type="SD" b1="EDDYSTON" b2="138 KV" b3="EDDYSTN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="138 KV" b3="425 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11980</SeqNum>
    <Name>L138.Eddystone-Llanerch.130-45</Name>
    <LastEdit Timestamp="2025-09-05T11:58:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="138 KV" b3="455" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDDYSTON" b2="138 KV" b3="EDD-LLA5" />
      <ContingencyEquipment Action="S" Type="SD" b1="EDDYSTON" b2="138 KV" b3="EDDYSTN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="13 KV" b3="13-12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LLANERCH" b2="13 KV" b3="13BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="138 KV" b3="455 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LLANERCH" b2="138 KV" b3="LAN 13TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>11990</SeqNum>
    <Name>L69.Burholme-DLuzerne-Waneeta-Richmond.6601</Name>
    <LastEdit Timestamp="2025-04-10T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURHOLME" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURHOLME" b2="69 KV" b3="260 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURHOLME" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURHOLME" b2="13 KV" b3="5TRLS CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURHOLME" b2="69 KV" b3="BUR-DLU" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURHOLME" b2="69 KV" b3="BUR1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURHOLME" b2="69 KV" b3="BUR3TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURHOLME" b2="69 KV" b3="BUR5TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="DLUZERNE" b2="69 KV" b3="DLU-RIC" />
      <ContingencyEquipment Action="L" Type="LN" b1="DLUZERNE" b2="69 KV" b3="DLU-WAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="69 KV" b3="50CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="69 KV" b3="60 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="138 KV" b3="895 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="69 KV" b3="905 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WANEETA" b2="138 KV" b3="WAN 9TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12000</SeqNum>
    <Name>L69.Master-University.6608</Name>
    <LastEdit Timestamp="2024-12-06T13:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MASTER" b2="138 KV" b3="245 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MASTER" b2="138 KV" b3="MAS 4TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="MASTER" b2="69 KV" b3="MAS-UNI" />
      <ContingencyEquipment Action="S" Type="SD" b1="MASTER" b2="69 KV" b3="MASTREAC" />
      <ContingencyEquipment Action="X" Type="XF" b1="UNIVERSI" b2="69 KV" b3="4TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIVERSI" b2="13 KV" b3="4TRLSBKR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIVERSI" b2="69 KV" b3="785 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12010</SeqNum>
    <Name>L69.Civic-University</Name>
    <LastEdit Timestamp="2025-12-17T14:49:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CIVIC" b2="69 KV" b3="105 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CIVIC" b2="69 KV" b3="115 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CIVIC" b2="69 KV" b3="CIV-UNIV" />
      <ContingencyEquipment Action="X" Type="XF" b1="UNIVERSI" b2="69 KV" b3="3TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIVERSI" b2="13 KV" b3="3TRLSBKR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIVERSI" b2="69 KV" b3="785 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12020</SeqNum>
    <Name>L69.Burholme-Byberry.6610</Name>
    <LastEdit Timestamp="2025-07-23T16:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURHOLME" b2="69 KV" b3="260 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURHOLME" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURHOLME" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURHOLME" b2="13 KV" b3="6TRLS CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURHOLME" b2="69 KV" b3="BUR-BYB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURHOLME" b2="69 KV" b3="BUR2TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURHOLME" b2="69 KV" b3="BUR4TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURHOLME" b2="69 KV" b3="BUR6TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BYBERRY" b2="69 KV" b3="70 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12030</SeqNum>
    <Name>L69.Schuylkill-Penn.6621</Name>
    <LastEdit Timestamp="2025-09-05T11:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PENN" b2="69 KV" b3="PEN-SCH1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PENN" b2="69 KV" b3="T1 DIS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PENN" b2="69 KV" b3="T4 DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="110 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="170 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12040</SeqNum>
    <Name>L69.IslandRoad-Civic</Name>
    <LastEdit Timestamp="2025-12-01T11:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CIVIC" b2="69 KV" b3="305 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CIVIC" b2="69 KV" b3="315 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="69 KV" b3="6623 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CIVIC" b2="69 KV" b3="CIV-ISLA" />
      <ContingencyEquipment Action="X" Type="XF" b1="ISLANDRD" b2="69 KV" b3="IR 1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="ISLANDRD" b2="69 KV" b3="IR 3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12050</SeqNum>
    <Name>L69.Civic - Schuylkill.1</Name>
    <LastEdit Timestamp="2025-10-29T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CIVIC" b2="69 KV" b3="215 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CIVIC" b2="69 KV" b3="225 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CIVIC" b2="69 KV" b3="CIV-SHUY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="120 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="130 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12060</SeqNum>
    <Name>L69.Lombard-Schuylkill.6627</Name>
    <LastEdit Timestamp="2026-02-27T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOMBARD" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOMBARD" b2="13 KV" b3="8TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOMBARD" b2="69 KV" b3="LOM 1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOMBARD" b2="69 KV" b3="LOM 8TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOMBARD" b2="69 KV" b3="LOM-SCH7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="240 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="250 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12070</SeqNum>
    <Name>L69.Penn-Schuylkill.6628</Name>
    <LastEdit Timestamp="2025-09-05T11:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PENN" b2="69 KV" b3="PEN-SCH8" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PENN" b2="69 KV" b3="T2 DIS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PENN" b2="69 KV" b3="T3 DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="210 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="220 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12080</SeqNum>
    <Name>L69.Angora-UpperDarby.6629</Name>
    <LastEdit Timestamp="2026-02-27T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGORA" b2="69 KV" b3="1TRHS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGORA" b2="69 KV" b3="210 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANGORA" b2="69 KV" b3="ANG-UPP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UPPERDAR" b2="69 KV" b3="13TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERDAR" b2="69 KV" b3="295 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12090</SeqNum>
    <Name>L69.Passyunk-Schuylkill.6630</Name>
    <LastEdit Timestamp="2026-02-27T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PASSYUNK" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PASSYUNK" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PASSYUNK" b2="69 KV" b3="PAS 1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="PASSYUNK" b2="69 KV" b3="PAS 4TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="PASSYUNK" b2="69 KV" b3="PAS-SCH0" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="310 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="360 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12100</SeqNum>
    <Name>L69.Passyunk-Schuylkill.6631</Name>
    <LastEdit Timestamp="2026-02-27T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PASSYUNK" b2="69 KV" b3="235 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PASSYUNK" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PASSYUNK" b2="13 KV" b3="5TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PASSYUNK" b2="69 KV" b3="PAS 2TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="PASSYUNK" b2="69 KV" b3="PAS 5TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="PASSYUNK" b2="69 KV" b3="PAS-SCH1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="220 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="230 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12110</SeqNum>
    <Name>L69.Lombard-Schuylkill.6632</Name>
    <LastEdit Timestamp="2025-09-05T10:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOMBARD" b2="13 KV" b3="3TR2LSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOMBARD" b2="13 KV" b3="3TR3LSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOMBARD" b2="13 KV" b3="6TR6LSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOMBARD" b2="13 KV" b3="6TR7LSCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOMBARD" b2="69 KV" b3="LOM 3TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOMBARD" b2="69 KV" b3="LOM 6TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOMBARD" b2="69 KV" b3="LOM-SCH2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="320 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="905 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12120</SeqNum>
    <Name>L69.Packer-Southwark + Southwark.CT5-6</Name>
    <LastEdit Timestamp="2025-09-05T11:59:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PACKER" b2="69 KV" b3="785 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PACKER" b2="69 KV" b3="LD2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PACKER" b2="69 KV" b3="PAC-SWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWARK" b2="69 KV" b3="125 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWARK" b2="69 KV" b3="355 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SWARK" b2="69 KV" b3="SWK56TR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SWARK" b2="13 KV" b3="UNIT5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SWARK" b2="13 KV" b3="UNIT6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12130</SeqNum>
    <Name>L69.Tuna-Delaware-SouthWark + Dela.CTs + SWark.CTs</Name>
    <LastEdit Timestamp="2025-01-16T16:03:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="DELA PE" b2="69 KV" b3="6636REAC" />
      <ContingencyEquipment Action="X" Type="XF" b1="DELA PE" b2="69 KV" b3="DEL 1TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELA PE" b2="69 KV" b3="DEL-SWA" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELA PE" b2="69 KV" b3="DEL-TUN6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA PE" b2="13 KV" b3="UNIT09" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA PE" b2="13 KV" b3="UNIT10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA PE" b2="13 KV" b3="UNIT11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA PE" b2="13 KV" b3="UNIT12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWARK" b2="69 KV" b3="125 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWARK" b2="69 KV" b3="15 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWARK" b2="69 KV" b3="375 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SWARK" b2="69 KV" b3="SWK34TR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SWARK" b2="13 KV" b3="UNIT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SWARK" b2="13 KV" b3="UNIT4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="69 KV" b3="140" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="69 KV" b3="150" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12140</SeqNum>
    <Name>L69.Tuna-NorthPhiladelphia.6638</Name>
    <LastEdit Timestamp="2025-11-24T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="69 KV" b3="85 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="NPHILADE" b2="69 KV" b3="NP 2TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="NPHILADE" b2="69 KV" b3="NP 4TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="69 KV" b3="110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="69 KV" b3="160" />
      <ContingencyEquipment Action="L" Type="LN" b1="NPHILADE" b2="69 KV" b3="NPH-TUN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12150</SeqNum>
    <Name>L69.NorthPhiladelphia-Westmoreland-Richmond.6607</Name>
    <LastEdit Timestamp="2025-11-24T09:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="69 KV" b3="75 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="NPHILADE" b2="69 KV" b3="NP 1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="NPHILADE" b2="69 KV" b3="NP 3TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="NPHILADE" b2="69 KV" b3="NPH-WMO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="69 KV" b3="30 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="69 KV" b3="50CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="RICH PE" b2="69 KV" b3="RIC-WMO7" />
      <ContingencyEquipment Action="S" Type="SD" b1="WMORELAN" b2="69 KV" b3="WESTREAC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12160</SeqNum>
    <Name>L69.IslandRoad-Packer.6641</Name>
    <LastEdit Timestamp="2024-12-30T14:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="69 KV" b3="6641 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ISLANDRD" b2="69 KV" b3="ISL-PAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PACKER" b2="69 KV" b3="785 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PACKER" b2="69 KV" b3="LD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12170</SeqNum>
    <Name>L69.Chichester-MarcusHook.6651</Name>
    <LastEdit Timestamp="2026-02-27T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="69 KV" b3="515 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICHEST" b2="69 KV" b3="CHI-MAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARCUSHO" b2="69 KV" b3="200 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARCUSHO" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARCUSHO" b2="69 KV" b3="MAR 4TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12180</SeqNum>
    <Name>L69.Chester-MarcusHook.6653</Name>
    <LastEdit Timestamp="2025-03-24T10:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER" b2="69 KV" b3="535 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTER" b2="69 KV" b3="CHE-MARC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARCUSHO" b2="69 KV" b3="200 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARCUSHO" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARCUSHO" b2="69 KV" b3="MAR 3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12190</SeqNum>
    <Name>L69.Llanerch-UpperDarby.6657</Name>
    <LastEdit Timestamp="2026-02-27T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="69 KV" b3="575 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LLANERCH" b2="69 KV" b3="LLA-UPP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UPPERDAR" b2="69 KV" b3="11TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERDAR" b2="69 KV" b3="575 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12200</SeqNum>
    <Name>L69.Eddystone - Scott Paper</Name>
    <LastEdit Timestamp="2026-02-27T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="69 KV" b3="585 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDDYSTON" b2="69 KV" b3="EDD-SCO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOTTPAP" b2="69 KV" b3="585 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12210</SeqNum>
    <Name>L69.Cedarbrook-Westmoreland.6668</Name>
    <LastEdit Timestamp="2026-03-03T10:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARBRO" b2="69 KV" b3="125 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARBRO" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARBRO" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CEDARBRO" b2="69 KV" b3="CED 1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CEDARBRO" b2="69 KV" b3="CED 3TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARBRO" b2="69 KV" b3="CED-WMO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="69 KV" b3="20 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="69 KV" b3="60 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12220</SeqNum>
    <Name>L69.Cedarbrook-Whitemarsh</Name>
    <LastEdit Timestamp="2025-11-18T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARBRO" b2="69 KV" b3="215 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARBRO" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARBRO" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CEDARBRO" b2="69 KV" b3="CED 2TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CEDARBRO" b2="69 KV" b3="CED 4TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARBRO" b2="69 KV" b3="CED-WHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEMAR" b2="69 KV" b3="695 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12230</SeqNum>
    <Name>L69.Pencoyd-Roxborough.6674</Name>
    <LastEdit Timestamp="2024-12-31T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENCOYD" b2="69 KV" b3="220 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENCOYD" b2="69 KV" b3="2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENCOYD" b2="13 KV" b3="2TRLSBKR" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENCOYD" b2="69 KV" b3="4TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENCOYD" b2="13 KV" b3="4TRLSBKR" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENCOYD" b2="69 KV" b3="PEN-ROX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBOROU" b2="69 KV" b3="745" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12240</SeqNum>
    <Name>L69.Roxborough-Westmoreland</Name>
    <LastEdit Timestamp="2025-11-18T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBOROU" b2="69 KV" b3="215 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBOROU" b2="13 KV" b3="6TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROXBOROU" b2="69 KV" b3="ROX 6TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROXBOROU" b2="69 KV" b3="ROX-WMO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="69 KV" b3="30 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELAN" b2="69 KV" b3="50 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12250</SeqNum>
    <Name>L69.Pencoyd-Master.6616</Name>
    <LastEdit Timestamp="2024-12-31T13:41:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MASTER" b2="69 KV" b3="165 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENCOYD" b2="69 KV" b3="1 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENCOYD" b2="13 KV" b3="1TRLSBKR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENCOYD" b2="69 KV" b3="220 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENCOYD" b2="69 KV" b3="3TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENCOYD" b2="13 KV" b3="3TRLSBKR" />
      <ContingencyEquipment Action="L" Type="LN" b1="MASTER" b2="69 KV" b3="MAS-PENC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12260</SeqNum>
    <Name>L69.Cromby-Limertap-Moser.6680</Name>
    <LastEdit Timestamp="2024-08-19T13:50:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="69 KV" b3="340 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROMBY" b2="69 KV" b3="CRO-LIM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERTAP" b2="69 KV" b3="805" />
      <ContingencyEquipment Action="X" Type="XF" b1="LIMERTAP" b2="69 KV" b3="80_TRANS" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIMERTAP" b2="69 KV" b3="LIM-MOS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="35 KV" b3="10 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="69 KV" b3="125 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOSER" b2="69 KV" b3="MOS 1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12270</SeqNum>
    <Name>L69.Cromby-Moser.6681</Name>
    <LastEdit Timestamp="2025-10-16T13:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="69 KV" b3="360 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROMBY" b2="69 KV" b3="CRO-MOS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="69 KV" b3="235 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="35 KV" b3="30 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOSER" b2="69 KV" b3="MOS 3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12290</SeqNum>
    <Name>L69.Goshen-Planebrook</Name>
    <LastEdit Timestamp="2025-07-31T13:58:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOSHEN" b2="69 KV" b3="125 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOSHEN" b2="69 KV" b3="15 CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOSHEN" b2="35 KV" b3="BUS1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOSHEN" b2="69 KV" b3="GOS-PLA" />
      <ContingencyEquipment Action="X" Type="XF" b1="GOSHEN" b2="69 KV" b3="TR 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="69 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="69 KV" b3="815" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12300</SeqNum>
    <Name>L69.Goshen-NewtownSquare-Middletown.6902</Name>
    <LastEdit Timestamp="2026-03-02T17:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOSHEN" b2="69 KV" b3="235 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOSHEN" b2="69 KV" b3="25 CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOSHEN" b2="35 KV" b3="BUS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOSHEN" b2="69 KV" b3="GOS-GOS" />
      <ContingencyEquipment Action="X" Type="XF" b1="GOSHEN" b2="69 KV" b3="TR 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOSHNTAP" b2="69 KV" b3="GOS-MID" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOSHNTAP" b2="69 KV" b3="GOS-NEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD PE" b2="69 KV" b3="025 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDD PE" b2="230 KV" b3="MID 9TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTOWNS" b2="69 KV" b3="235" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWTOWNS" b2="69 KV" b3="2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTOWNS" b2="13 KV" b3="2TRLS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12310</SeqNum>
    <Name>138/13.Bluegrass.5TR</Name>
    <LastEdit Timestamp="2026-03-02T17:34:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEGRAS" b2="138 KV" b3="165 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEGRAS" b2="13 KV" b3="5TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEGRAS" b2="138 KV" b3="805 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUEGRAS" b2="138 KV" b3="BLU 5TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12320</SeqNum>
    <Name>230/35.Buckingham.4TR</Name>
    <LastEdit Timestamp="2025-09-05T10:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKINGH" b2="230 KV" b3="245" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKINGH" b2="35 KV" b3="40 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUCKINGH" b2="230 KV" b3="BUCK4TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12340</SeqNum>
    <Name>35/13.Falls.4TR</Name>
    <LastEdit Timestamp="2026-03-02T17:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLS" b2="13 KV" b3="1 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLS" b2="13 KV" b3="2 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLS" b2="13 KV" b3="3 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLS" b2="35 KV" b3="40 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FALLS" b2="35 KV" b3="FALL4TR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FALLS" b2="13 KV" b3="UNIT01" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FALLS" b2="13 KV" b3="UNIT02" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FALLS" b2="13 KV" b3="UNIT03" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12350</SeqNum>
    <Name>138/13.Foxchase.6TR</Name>
    <LastEdit Timestamp="2026-03-02T17:35:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOXCHASE" b2="138 KV" b3="245 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOXCHASE" b2="13 KV" b3="6TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOXCHASE" b2="138 KV" b3="985 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FOXCHASE" b2="138 KV" b3="FOX 6TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12360</SeqNum>
    <Name>138/69.Holmesburg.T9&amp;T13</Name>
    <LastEdit Timestamp="2026-02-25T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLMESBU" b2="69 KV" b3="065 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLMESBU" b2="13 KV" b3="13TRLSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLMESBU" b2="138 KV" b3="905 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOLMESBU" b2="138 KV" b3="HOL 9TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOLMESBU" b2="138 KV" b3="HOL13TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12370</SeqNum>
    <Name>69/13.Island Road.2TR+4TR</Name>
    <LastEdit Timestamp="2025-09-05T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="69 KV" b3="24TRHSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ISLANDRD" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ISLANDRD" b2="69 KV" b3="IR 2TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="ISLANDRD" b2="69 KV" b3="IR 4TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12380</SeqNum>
    <Name>230/13.Jenkintown.2TR+11TR</Name>
    <LastEdit Timestamp="2026-03-02T17:36:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINTO" b2="13 KV" b3="11TRLSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINTO" b2="230 KV" b3="210 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINTO" b2="230 KV" b3="230 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINTO" b2="35 KV" b3="80 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="JENKINTO" b2="230 KV" b3="JENK 2T" />
      <ContingencyEquipment Action="X" Type="XF" b1="JENKINTO" b2="230 KV" b3="JENK11T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12390</SeqNum>
    <Name>230/13.MacDade.2TR</Name>
    <LastEdit Timestamp="2025-06-05T08:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MACDADE" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACDADE" b2="230 KV" b3="805 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACDADE" b2="230 KV" b3="905 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MACDADE" b2="230 KV" b3="MCDADE2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12400</SeqNum>
    <Name>69/35.Moser.2TR</Name>
    <LastEdit Timestamp="2026-03-02T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="69 KV" b3="125 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="69 KV" b3="235 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="35 KV" b3="50 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="35 KV" b3="70 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOSER" b2="69 KV" b3="MOS 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12410</SeqNum>
    <Name>35/13.Moser.4TR</Name>
    <LastEdit Timestamp="2026-03-02T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="13 KV" b3="1 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="13 KV" b3="2 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="13 KV" b3="3 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="35 KV" b3="40 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOSER" b2="35 KV" b3="MOS 4TR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOSER" b2="13 KV" b3="UNIT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOSER" b2="13 KV" b3="UNIT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOSER" b2="13 KV" b3="UNIT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12430</SeqNum>
    <Name>69/13.Passyunk.3TR+6TR</Name>
    <LastEdit Timestamp="2026-03-02T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PASSYUNK" b2="69 KV" b3="325 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PASSYUNK" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PASSYUNK" b2="69 KV" b3="435 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PASSYUNK" b2="13 KV" b3="6TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PASSYUNK" b2="69 KV" b3="PAS 3TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="PASSYUNK" b2="69 KV" b3="PAS 6TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12440</SeqNum>
    <Name>230/35.Planebrook.T2</Name>
    <LastEdit Timestamp="2026-03-02T17:38:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="35 KV" b3="20 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PLANEBRO" b2="230 KV" b3="8-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="805" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="885" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="985 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLANEBRO" b2="230 KV" b3="PLA 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12450</SeqNum>
    <Name>230/69.Planebrook.T9 + 230/35.Planebrook.T3</Name>
    <LastEdit Timestamp="2026-03-02T17:39:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="095" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="35 KV" b3="30 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="315 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="69 KV" b3="935" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="985 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLANEBRO" b2="230 KV" b3="PLA 3TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLANEBRO" b2="230 KV" b3="PLA 9TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12460</SeqNum>
    <Name>230/69.Schuylkill.7TR</Name>
    <LastEdit Timestamp="2025-10-02T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="775 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYSFER" b2="230 KV" b3="GRA-SCH7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="140 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="150 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCHUYLKI" b2="230 KV" b3="SCH 7TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12470</SeqNum>
    <Name>230/69.Schuylkill.8TR</Name>
    <LastEdit Timestamp="2025-09-04T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="985 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYSFER" b2="230 KV" b3="GRA-SCH8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="230 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="240 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCHUYLKI" b2="230 KV" b3="SCH 8TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12480</SeqNum>
    <Name>69/13.Tacony.1TR</Name>
    <LastEdit Timestamp="2026-03-10T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TACONY" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TACONY" b2="69 KV" b3="215 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TACONY" b2="69 KV" b3="65 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="TACONY" b2="69 KV" b3="TAC 1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12490</SeqNum>
    <Name>69/13.Tacony.2TR</Name>
    <LastEdit Timestamp="2026-03-10T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TACONY" b2="69 KV" b3="215 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TACONY" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TACONY" b2="69 KV" b3="55 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="TACONY" b2="69 KV" b3="TAC 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12500</SeqNum>
    <Name>69/35.UpperDarby.6TR</Name>
    <LastEdit Timestamp="2025-11-17T15:07:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERDAR" b2="35 KV" b3="40 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERDAR" b2="69 KV" b3="65 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERDAR" b2="35 KV" b3="80 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="UPPERDAR" b2="69 KV" b3="UPD 6TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12510</SeqNum>
    <Name>230/69.Whitemarsh.7TR</Name>
    <LastEdit Timestamp="2025-11-18T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEMAR" b2="69 KV" b3="185 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEMAR" b2="69 KV" b3="695 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEMAR" b2="230 KV" b3="75 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHITEMAR" b2="230 KV" b3="WHIT7TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12520</SeqNum>
    <Name>138/35.Heaton.2TR&amp;3TR</Name>
    <LastEdit Timestamp="2025-01-13T14:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="138 KV" b3="150 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="13 KV" b3="3TRLS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="35 KV" b3="80 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="138 KV" b3="995 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="HEATON" b2="138 KV" b3="HEA 2TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="HEATON" b2="138 KV" b3="HEA 3TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="HEATON" b2="230 KV" b3="HEA 9TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12580</SeqNum>
    <Name>DTX230.Chichester.T1</Name>
    <LastEdit Timestamp="2025-05-13T07:55:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="230 KV" b3="235" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHICHEST" b2="230 KV" b3="DBU1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12590</SeqNum>
    <Name>DTX230.Chichester.T2</Name>
    <LastEdit Timestamp="2026-03-10T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="230 KV" b3="255 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHICHEST" b2="230 KV" b3="DBU2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12630</SeqNum>
    <Name>DTX230.WayneJct.T2</Name>
    <LastEdit Timestamp="2025-01-17T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNEJCT" b2="230 KV" b3="1A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNEJCT" b2="230 KV" b3="1T DIS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="WAYNEJCT" b2="230 KV" b3="2A CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAYNEJCT" b2="230 KV" b3="DBU2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12640</SeqNum>
    <Name>Buckingham.230.Cap</Name>
    <LastEdit Timestamp="2026-03-10T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKINGH" b2="230 KV" b3="115 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BUCKINGH" b2="230 KV" b3="BUCK 1-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12650</SeqNum>
    <Name>NorthWales.230.Cap10-1</Name>
    <LastEdit Timestamp="2026-03-06T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NWALES" b2="230 KV" b3="105" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NWALES" b2="230 KV" b3="CAP 10-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12660</SeqNum>
    <Name>Woodbourne.230.Cap</Name>
    <LastEdit Timestamp="2026-03-27T09:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="WOODBOUR" b2="230 KV" b3="10-1_CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODBOUR" b2="230 KV" b3="105 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12670</SeqNum>
    <Name>Conowingo.U1</Name>
    <LastEdit Timestamp="2026-03-02T17:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="1 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12680</SeqNum>
    <Name>Conowingo.U2</Name>
    <LastEdit Timestamp="2026-03-02T17:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="2 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12690</SeqNum>
    <Name>Conowingo.U3</Name>
    <LastEdit Timestamp="2026-03-02T17:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="3 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12700</SeqNum>
    <Name>Conowingo.U4</Name>
    <LastEdit Timestamp="2026-03-02T17:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="4 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12710</SeqNum>
    <Name>Conowingo.U5</Name>
    <LastEdit Timestamp="2026-03-03T10:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="5 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12720</SeqNum>
    <Name>Conowingo.U6</Name>
    <LastEdit Timestamp="2026-03-03T10:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="6 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12730</SeqNum>
    <Name>Conowingo.U7</Name>
    <LastEdit Timestamp="2026-03-03T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="7 GEN CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONOWING" b2="230 KV" b3="CONO4TR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="UNIT07" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12740</SeqNum>
    <Name>Conowingo.U8</Name>
    <LastEdit Timestamp="2026-03-05T15:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="8 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12750</SeqNum>
    <Name>Conowingo.U9</Name>
    <LastEdit Timestamp="2026-03-05T15:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="9 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12760</SeqNum>
    <Name>Conowingo.U10</Name>
    <LastEdit Timestamp="2026-03-02T17:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="10GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="G10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12770</SeqNum>
    <Name>Conowingo.U11</Name>
    <LastEdit Timestamp="2026-03-02T17:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="11GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="G11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12780</SeqNum>
    <Name>Croydon.CT11 </Name>
    <LastEdit Timestamp="2025-03-27T15:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="11 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12790</SeqNum>
    <Name>Croydon.CT12</Name>
    <LastEdit Timestamp="2025-03-27T15:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="12 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12800</SeqNum>
    <Name>Croydon.CT21</Name>
    <LastEdit Timestamp="2025-03-27T15:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="21 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT21" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12810</SeqNum>
    <Name>Croydon.CT22</Name>
    <LastEdit Timestamp="2025-03-27T15:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="22 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12820</SeqNum>
    <Name>Croydon.CT31</Name>
    <LastEdit Timestamp="2025-03-27T15:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="31 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT31" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12830</SeqNum>
    <Name>Croydon.CT32</Name>
    <LastEdit Timestamp="2025-03-27T15:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="32 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT32" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12840</SeqNum>
    <Name>Croydon.CT41</Name>
    <LastEdit Timestamp="2025-03-27T15:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="41 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT41" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12850</SeqNum>
    <Name>Croydon.CT42</Name>
    <LastEdit Timestamp="2025-03-27T15:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROYDON" b2="13 KV" b3="42 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROYDON" b2="13 KV" b3="UNIT42" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12860</SeqNum>
    <Name>Delaware.CT9</Name>
    <LastEdit Timestamp="2026-03-10T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA PE" b2="13 KV" b3="9 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA PE" b2="13 KV" b3="UNIT09" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12870</SeqNum>
    <Name>Delaware.CT10</Name>
    <LastEdit Timestamp="2026-03-10T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA PE" b2="13 KV" b3="10 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA PE" b2="13 KV" b3="UNIT10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12880</SeqNum>
    <Name>Delaware.CT11</Name>
    <LastEdit Timestamp="2026-03-10T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA PE" b2="13 KV" b3="11 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA PE" b2="13 KV" b3="UNIT11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12890</SeqNum>
    <Name>Delaware.CT12</Name>
    <LastEdit Timestamp="2026-03-10T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA PE" b2="13 KV" b3="12 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA PE" b2="13 KV" b3="UNIT12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12900</SeqNum>
    <Name>Eddystone.CT30</Name>
    <LastEdit Timestamp="2026-03-10T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="13 KV" b3="30 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDDYSTON" b2="13 KV" b3="UNIT30" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12910</SeqNum>
    <Name>Eddystone.CT40</Name>
    <LastEdit Timestamp="2026-03-10T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="13 KV" b3="40 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDDYSTON" b2="13 KV" b3="UNIT40" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12920</SeqNum>
    <Name>Falls.CT1</Name>
    <LastEdit Timestamp="2026-03-10T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLS" b2="13 KV" b3="1 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FALLS" b2="13 KV" b3="UNIT01" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12930</SeqNum>
    <Name>Falls.CT2</Name>
    <LastEdit Timestamp="2026-03-10T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLS" b2="13 KV" b3="2 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FALLS" b2="13 KV" b3="UNIT02" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12940</SeqNum>
    <Name>Falls.CT3</Name>
    <LastEdit Timestamp="2026-03-10T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLS" b2="13 KV" b3="3 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FALLS" b2="13 KV" b3="UNIT03" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12970</SeqNum>
    <Name>NWales.Merck.COGEN</Name>
    <LastEdit Timestamp="2026-03-12T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MERCK" b2="13 KV" b3="COGEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCK" b2="13 KV" b3="TG3-13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12980</SeqNum>
    <Name>Moser.CT1</Name>
    <LastEdit Timestamp="2026-03-05T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="13 KV" b3="1 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOSER" b2="13 KV" b3="UNIT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>12990</SeqNum>
    <Name>Moser.CT2</Name>
    <LastEdit Timestamp="2026-03-05T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="13 KV" b3="2 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOSER" b2="13 KV" b3="UNIT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13000</SeqNum>
    <Name>Moser.CT3</Name>
    <LastEdit Timestamp="2026-03-05T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSER" b2="13 KV" b3="3 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOSER" b2="13 KV" b3="UNIT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13010</SeqNum>
    <Name>MuddyRun.U1</Name>
    <LastEdit Timestamp="2026-03-05T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUDDYRN" b2="13 KV" b3="1 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13020</SeqNum>
    <Name>MuddyRun.U2</Name>
    <LastEdit Timestamp="2026-03-05T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUDDYRN" b2="13 KV" b3="2 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13030</SeqNum>
    <Name>MuddyRun.U3</Name>
    <LastEdit Timestamp="2026-03-05T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUDDYRN" b2="13 KV" b3="3 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13040</SeqNum>
    <Name>MuddyRun.U4</Name>
    <LastEdit Timestamp="2026-03-05T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUDDYRN" b2="13 KV" b3="4 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13050</SeqNum>
    <Name>MuddyRun.U5</Name>
    <LastEdit Timestamp="2026-03-05T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUDDYRN" b2="13 KV" b3="5 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13060</SeqNum>
    <Name>MuddyRun.U6</Name>
    <LastEdit Timestamp="2026-03-06T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUDDYRN" b2="13 KV" b3="6 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13070</SeqNum>
    <Name>MuddyRun.U7</Name>
    <LastEdit Timestamp="2026-03-06T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUDDYRN" b2="13 KV" b3="7 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13080</SeqNum>
    <Name>MuddyRun.U8</Name>
    <LastEdit Timestamp="2026-03-06T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUDDYRN" b2="13 KV" b3="8 GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13090</SeqNum>
    <Name>Richmond.CT91</Name>
    <LastEdit Timestamp="2026-03-06T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="13 KV" b3="91 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RICH PE" b2="13 KV" b3="UNIT91" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13100</SeqNum>
    <Name>Richmond.CT92</Name>
    <LastEdit Timestamp="2026-03-06T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="13 KV" b3="92 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RICH PE" b2="13 KV" b3="UNIT92" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13120</SeqNum>
    <Name>Schuylkill.CT10</Name>
    <LastEdit Timestamp="2026-03-06T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="13 KV" b3="10 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SCHUYLKI" b2="13 KV" b3="UNIT10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13130</SeqNum>
    <Name>Schuylkill.CT11</Name>
    <LastEdit Timestamp="2026-03-06T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="13 KV" b3="11 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SCHUYLKI" b2="13 KV" b3="UNIT11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13140</SeqNum>
    <Name>Southwark.CT3</Name>
    <LastEdit Timestamp="2026-03-06T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SWARK" b2="13 KV" b3="3 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SWARK" b2="13 KV" b3="UNIT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13150</SeqNum>
    <Name>Southwark.CT4</Name>
    <LastEdit Timestamp="2026-03-06T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SWARK" b2="13 KV" b3="4 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SWARK" b2="13 KV" b3="UNIT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13160</SeqNum>
    <Name>Southwark.CT5</Name>
    <LastEdit Timestamp="2026-03-06T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SWARK" b2="13 KV" b3="5 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SWARK" b2="13 KV" b3="UNIT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13170</SeqNum>
    <Name>Southwark.CT6</Name>
    <LastEdit Timestamp="2026-03-06T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SWARK" b2="13 KV" b3="6 CT CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SWARK" b2="13 KV" b3="UNIT6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13190</SeqNum>
    <Name>L138.Weirton-AepTP-WylieRidge + 138/69.SToronto.T1</Name>
    <LastEdit Timestamp="2025-02-18T15:25:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AEPTAP" b2="138 KV" b3="AEP-STO" />
      <ContingencyEquipment Action="L" Type="LN" b1="AEPTAP" b2="138 KV" b3="AEP-WEI" />
      <ContingencyEquipment Action="L" Type="LN" b1="AEPTAP" b2="138 KV" b3="AEP-WYL" />
      <ContingencyEquipment Action="X" Type="XF" b1="STORONT2" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STORONT2" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEIRTON" b2="138 KV" b3="APTAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="B241" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="B44" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13220</SeqNum>
    <Name>L138.Albright-BrandJCT-Hazelton-LakeLynn</Name>
    <LastEdit Timestamp="2025-02-07T11:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBRIGHT" b2="138 KV" b3="ALB-BRJ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBRIGHT" b2="138 KV" b3="BRANDJCT" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDJCT" b2="138 KV" b3="BRA-HAZ" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDJCT" b2="138 KV" b3="BRA-LAK" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAZELTON" b2="138 KV" b3="BRANDJCT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKELYNN" b2="138 KV" b3="BRANDJCT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13230</SeqNum>
    <Name>L138.Albright-Denver-Intcoal-Grafton</Name>
    <LastEdit Timestamp="2026-03-02T17:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBRIGHT" b2="138 KV" b3="ALB-DEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBRIGHT" b2="138 KV" b3="DENVER" />
      <ContingencyEquipment Action="L" Type="LN" b1="DENVER" b2="138 KV" b3="DEN-INT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DENVER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DENVER" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAFTON" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAFTON" b2="138 KV" b3="GRA-INT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INTCOAL" b2="138 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13280</SeqNum>
    <Name>L138.Albright-Garrett.AR1</Name>
    <LastEdit Timestamp="2026-05-12T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBRIGHT" b2="138 KV" b3="ALB-GAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBRIGHT" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARRETT" b2="138 KV" b3="CARLOJCT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GARRETT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARRETT" b2="138 KV" b3="T2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GARRETT" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13290</SeqNum>
    <Name>L138.Albright-Mettiki-Rothrock-William</Name>
    <LastEdit Timestamp="2026-03-02T17:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBRIGHT" b2="138 KV" b3="ALB-MET" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBRIGHT" b2="138 KV" b3="METTIKI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="METTIKI" b2="138 KV" b3="METTIKI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROTHROCK" b2="138 KV" b3="GEN" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROTHROCK" b2="138 KV" b3="ROT-MET" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROTHROCK" b2="34.5 KV" b3="ROTHRKWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROTHROCK" b2="138 KV" b3="TRAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="METTIKI" b2="138 KV" b3="MET-WIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLIAM" b2="138 KV" b3="METTIKI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13300</SeqNum>
    <Name>William.Backbone</Name>
    <LastEdit Timestamp="2025-03-13T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLIAM" b2="138 KV" b3="BACKBONE" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WILLIAM" b2="34 KV" b3="BACKBONE" />
      <ContingencyEquipment Action="X" Type="XF" b1="WILLIAM" b2="138 KV" b3="XFGEN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13310</SeqNum>
    <Name>L138.Albright-Kitzmiller</Name>
    <LastEdit Timestamp="2025-10-22T10:31:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBRIGHT" b2="138 KV" b3="ALB-KITZ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBRIGHT" b2="138 KV" b3="MTZION" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITZMILR" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITZMILR" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13350</SeqNum>
    <Name>L138.Rivesville-Sanford-Alcan-StonyRd-Pruntytwn.34</Name>
    <LastEdit Timestamp="2025-08-25T10:42:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALCAN" b2="138 KV" b3="ALCAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALCAN" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="P7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVESVIL" b2="138 KV" b3="B34" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCAN" b2="138 KV" b3="ALC-SAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIVESVIL" b2="138 KV" b3="RIV-SAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SANFORD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCAN" b2="138 KV" b3="ALC-STO" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRUNTYTO" b2="138 KV" b3="PRU-STO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STONYRD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STONYRD" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STONYRD" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13360</SeqNum>
    <Name>AllDam6.U5&amp;6 </Name>
    <LastEdit Timestamp="2024-11-19T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="ALLDAM6" b2="138 KV" b3="GEN  5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ALLDAM6" b2="138 KV" b3="GEN  6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLDAM6" b2="138 KV" b3="GEN CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13370</SeqNum>
    <Name>L138.Kittanning-AllDam6</Name>
    <LastEdit Timestamp="2026-01-14T12:13:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLLUD4J" b2="138 KV" b3="ALJ-ALL" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLDAM6" b2="138 KV" b3="ALL-KIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLDAM6" b2="138 KV" b3="ALUD4JCT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ALLDAM6" b2="138 KV" b3="GEN  5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ALLDAM6" b2="138 KV" b3="GEN  6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLDAM6" b2="138 KV" b3="GEN CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTANNI" b2="138 KV" b3="ALLDAM6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13380</SeqNum>
    <Name>L138.KiskiValley-BrackenRidge-ShaffersCorner</Name>
    <LastEdit Timestamp="2025-01-16T11:23:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRACKENR" b2="138 KV" b3="BRDGJCT" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRACKENR" b2="138 KV" b3="BRA-BRAJ" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRACKNJC" b2="138 KV" b3="BRAJ-KIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRACKNJC" b2="138 KV" b3="BRAJ-SHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KISKIVAL" b2="138 KV" b3="BRDGJCT" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHAFFERS" b2="138 KV" b3="BRDGJCT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13390</SeqNum>
    <Name>L138.Allenport-Charleroi</Name>
    <LastEdit Timestamp="2024-09-30T13:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENPOR" b2="138 KV" b3="ALL-CHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENPOR" b2="138 KV" b3="CHARLERO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLERO" b2="138 KV" b3="ALLENPOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13400</SeqNum>
    <Name>L138.AllenPor-Frazr-LaytnJCT-IronBrdg-SmthTn-Yukon</Name>
    <LastEdit Timestamp="2025-11-21T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENPOR" b2="138 KV" b3="ALL-FRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENPOR" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRAZIER" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONBRID" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRAZIER" b2="138 KV" b3="FRA-LAY" />
      <ContingencyEquipment Action="L" Type="LN" b1="IRONBRID" b2="138 KV" b3="IRO-LAY" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAYTOJCT" b2="138 KV" b3="LAY-SMI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMITHTON" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SMITHTON" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="L" Type="LN" b1="SMITHTON" b2="138 KV" b3="SMI-YUK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="Y3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="Y5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13410</SeqNum>
    <Name>L138.Antietam-Reid</Name>
    <LastEdit Timestamp="2026-03-27T10:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ANTIETAM" b2="138 KV" b3="A1366" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANTIETAM" b2="138 KV" b3="ANT-REI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REID" b2="138 KV" b3="ANTIETAM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13430</SeqNum>
    <Name>L230.Aqueduct-DickersonH.23101/235</Name>
    <LastEdit Timestamp="2026-03-02T17:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AQUEDUCT" b2="230 KV" b3="AQU-DIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUEDUCT" b2="230 KV" b3="DICKERCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSH" b2="230 KV" b3="411C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13440</SeqNum>
    <Name>L230.Aqueduct-Doubs.201-1</Name>
    <LastEdit Timestamp="2025-08-26T17:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AQUEDUCT" b2="230 KV" b3="AQU-DOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUEDUCT" b2="230 KV" b3="DOUBSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13450</SeqNum>
    <Name>230/35.Aqueduct.T1</Name>
    <LastEdit Timestamp="2024-12-18T12:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AQUEDUCT" b2="230 KV" b3="AQU-DIC" />
      <ContingencyEquipment Action="L" Type="LN" b1="AQUEDUCT" b2="230 KV" b3="AQU-DOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUEDUCT" b2="230 KV" b3="DICKERCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUEDUCT" b2="230 KV" b3="DOUBSCB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="AQUEDUCT" b2="35 KV" b3="DUMLOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUEDUCT" b2="35 KV" b3="T1CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="AQUEDUCT" b2="230 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="35 KV" b3="ALPHA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LIMEKILN" b2="35 KV" b3="DUMFAI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="35 KV" b3="JEFFERSO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="35 KV" b3="SFREDRIK" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MONTGOME" b2="35 KV" b3="DUMLOAD1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MONTGOME" b2="35 KV" b3="DUMLOAD3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13460</SeqNum>
    <Name>L138.Armstrong-Burma</Name>
    <LastEdit Timestamp="2026-03-02T17:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMSTRON" b2="138 KV" b3="B32" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARMSTRON" b2="138 KV" b3="ARM-BUR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURMA" b2="138 KV" b3="ARMSTRON" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13470</SeqNum>
    <Name>L138.Armstrng-Kitanng-GarretJct-BigPineTap-KisKVly</Name>
    <LastEdit Timestamp="2024-06-27T07:03:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMSTRON" b2="138 KV" b3="B31" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ARMSTRON" b2="138 KV" b3="GARRNRES" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIGPINET" b2="138 KV" b3="BIG-KIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARMSTRON" b2="138 KV" b3="ARM-GAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIGPINET" b2="138 KV" b3="BIG-GAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARRNJCT" b2="138 KV" b3="GAR-KIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KISKIVAL" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTANNI" b2="138 KV" b3="GARRNJCT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13480</SeqNum>
    <Name>L138.Armstrong-Kittanning</Name>
    <LastEdit Timestamp="2026-03-02T17:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMSTRON" b2="138 KV" b3="B33" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARMSTRON" b2="138 KV" b3="ARM-KIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTANNI" b2="138 KV" b3="ARMSTRON" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13490</SeqNum>
    <Name>L138.Armstrong-NewBethlehem-Brookville.1101</Name>
    <LastEdit Timestamp="2025-02-25T19:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMSTRON" b2="138 KV" b3="B56" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BROOKVIL" b2="138 KV" b3="1 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKVIL" b2="138 KV" b3="BSSEC138" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARMSTRON" b2="138 KV" b3="ARM-NEW" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKVIL" b2="138 KV" b3="BRO-NEW" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWBETHL" b2="138 KV" b3="T62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13500</SeqNum>
    <Name>L138.Armstrong-KissingerJct-Burma-KarnsCity</Name>
    <LastEdit Timestamp="2025-05-13T10:05:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMSTRON" b2="138 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURMA" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KARNSCIT" b2="138 KV" b3="B19" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARMSTRON" b2="138 KV" b3="ARM-KIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURMA" b2="138 KV" b3="BUR-KIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="KARNSCIT" b2="138 KV" b3="KAR-KIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13550</SeqNum>
    <Name>L138.BackFork-Pickens.180</Name>
    <LastEdit Timestamp="2026-03-30T18:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BACKFORK" b2="138 KV" b3="PICK DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PICKENS" b2="138 KV" b3="B180" />
      <ContingencyEquipment Action="L" Type="LN" b1="BACKFORK" b2="138 KV" b3="BAC-PIC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13560</SeqNum>
    <Name>L138.Powell-Bays-Wolfrun-SuttonHill-Sutton</Name>
    <LastEdit Timestamp="2026-03-30T18:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAYS" b2="138 KV" b3="BAY-POW" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYS" b2="138 KV" b3="BAY-WOL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BAYS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POWELLMT" b2="138 KV" b3="B25" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUTTON" b2="138 KV" b3="SUT-SUT" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUTTON" b2="138 KV" b3="SUTTONHI" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUTTONHI" b2="138 KV" b3="SUT-SUTT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUTTONHI" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUTTONHI" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUTTONTP" b2="138 KV" b3="SUT-WOL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOLFRUN" b2="138 KV" b3="WOLFRUN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13580</SeqNum>
    <Name>500/138.Bedington.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-03-02T17:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEDINGTO" b2="500 KV" b3="TRAN  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="TRAN1HS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13590</SeqNum>
    <Name>500/138.Bedington.T2 + 500.Cap.2&amp;3 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-11-17T09:44:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="2CAPBDL7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="3CAPBDL8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD8" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BEDINGTO" b2="500 KV" b3="CAP2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BEDINGTO" b2="500 KV" b3="CAP3" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEDINGTO" b2="500 KV" b3="TRAN  2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="TRAN2HS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13600</SeqNum>
    <Name>500/138.Bedington.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-03-02T17:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD5" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEDINGTO" b2="500 KV" b3="TRAN  3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="TRAN3HS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13610</SeqNum>
    <Name>500/138.Bedington.T4 + 500.Cap.2&amp;3 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-11-17T09:44:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="2CAPBDL7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="3CAPBDL8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD10" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BEDINGTO" b2="500 KV" b3="CAP2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BEDINGTO" b2="500 KV" b3="CAP3" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEDINGTO" b2="500 KV" b3="TRAN  4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="TRAN4HS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13620</SeqNum>
    <Name>500/138.Bedington.T2&amp;T4 + 500.Cap.2&amp;3 (Sctnlz F)</Name>
    <LastEdit Timestamp="2026-01-15T14:49:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="2CAPBDL7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="3CAPBDL8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="BDL1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="500 KV" b3="BDL4 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BEDINGTO" b2="500 KV" b3="CAP2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BEDINGTO" b2="500 KV" b3="CAP3" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEDINGTO" b2="500 KV" b3="TRAN  2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEDINGTO" b2="500 KV" b3="TRAN  4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13630</SeqNum>
    <Name>L138.Bedington-CMCTap-Marlowe</Name>
    <LastEdit Timestamp="2025-11-14T11:15:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEDINGTO" b2="138 KV" b3="BED-CMC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARLOWE" b2="138 KV" b3="BEDINGT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CMC_T" b2="138 KV" b3="CMC-MAR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13640</SeqNum>
    <Name>L138.Bedington-Marlowe.BMR</Name>
    <LastEdit Timestamp="2025-10-02T10:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEDINGTO" b2="138 KV" b3="BED-MAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARLOWE" b2="138 KV" b3="BEDINGT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13650</SeqNum>
    <Name>L138.Bedington-Opequon</Name>
    <LastEdit Timestamp="2024-12-10T10:18:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD12" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEDINGTO" b2="138 KV" b3="BED-OPE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPEQUON" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPEQUON" b2="34.5 KV" b3="T3LSCB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OPEQUON" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="X" Type="XF" b1="OPEQUON" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13660</SeqNum>
    <Name>L138.Bedington-Shepherdstown</Name>
    <LastEdit Timestamp="2025-11-12T10:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD8" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEDINGTO" b2="138 KV" b3="BED-SHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEPERDS" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHEPERDS" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13670</SeqNum>
    <Name>L138.Bedington-HarmonyJct-Marlowe-CherryRun</Name>
    <LastEdit Timestamp="2026-03-30T18:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD13F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD14" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEDINGTO" b2="138 KV" b3="BED-HAR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHERRYRN" b2="138 KV" b3="A1348" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHERRYRN" b2="138 KV" b3="CHE-HAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARLOWE" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARMOJCT" b2="138 KV" b3="HAR-MAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13690</SeqNum>
    <Name>L138.Leadsville-Belington-UnionRoad-PruntyTown</Name>
    <LastEdit Timestamp="2025-01-15T18:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELINGTO" b2="138 KV" b3="BEL-LEA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELINGTO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEADSVIL" b2="138 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEADSVIL" b2="138 KV" b3="CB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="P5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="P6" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRUNTYTO" b2="138 KV" b3="PRU-UNI" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELINGTO" b2="138 KV" b3="BEL-UNI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIONRD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13700</SeqNum>
    <Name>L138.Charleroi-Belmon-SheplerJCT-Mitchell-Yukon</Name>
    <LastEdit Timestamp="2025-11-13T08:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELMON" b2="138 KV" b3="BEL-CHA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELMON" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELMON" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLERO" b2="138 KV" b3="BELMON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHELL" b2="138 KV" b3="SHEPLJCT" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMON" b2="138 KV" b3="BEL-SHE" />
      <ContingencyEquipment Action="L" Type="LN" b1="MITCHELL" b2="138 KV" b3="MIT-SHE" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHEPLJCT" b2="138 KV" b3="SHE-SMI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMITHTON" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SMITHTON" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="L" Type="LN" b1="SMITHTON" b2="138 KV" b3="SMI-YUK2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13710</SeqNum>
    <Name>L765.Kammer-Belmont-Mountaineer+765/500.Belmont.T5</Name>
    <LastEdit Timestamp="2025-10-08T04:18:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="765 KV" b3="BEL-KAM" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="765 KV" b3="BEL-MOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="500 KV" b3="BL10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="500 KV" b3="BL12" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELMONT" b2="765 KV" b3="TRAN  5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="765 KV" b3="PP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="765 KV" b3="PP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUNTAIN" b2="765 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUNTAIN" b2="765 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13740</SeqNum>
    <Name>500/138.Belmont.Tran1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-04-16T16:10:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELMONT" b2="500 KV" b3="TRAN  1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELMONT" b2="500 KV" b3="TX1 500" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13750</SeqNum>
    <Name>500/138.Belmont.Tran2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-04-16T16:10:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELMONT" b2="500 KV" b3="TRAN  2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELMONT" b2="500 KV" b3="TX2 500" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13760</SeqNum>
    <Name>500/138.Belmont.Tran3</Name>
    <LastEdit Timestamp="2025-10-10T12:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="500 KV" b3="B109" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="500 KV" b3="BL12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="500 KV" b3="BL3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="500 KV" b3="BL6" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELMONT" b2="500 KV" b3="TRAN  3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13780</SeqNum>
    <Name>L69.HaringsCorner-Montvale</Name>
    <LastEdit Timestamp="2026-03-05T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARINGSC" b2="69 KV" b3="658-30-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARINGSC" b2="69 KV" b3="HAR-MON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTVALE" b2="69 KV" b3="658-29-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13790</SeqNum>
    <Name>L138.Belmont-Edgelawn.628</Name>
    <LastEdit Timestamp="2026-03-30T18:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGELAWN" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="138 KV" b3="BEL-EDG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13800</SeqNum>
    <Name>L138.Belmont-OakGrove.606</Name>
    <LastEdit Timestamp="2026-03-10T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="138 KV" b3="BEL-OAK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKG APS" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKG APS" b2="138 KV" b3="3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13810</SeqNum>
    <Name>L138.Belmont-Trissler.604</Name>
    <LastEdit Timestamp="2024-05-15T09:35:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISSLER" b2="138 KV" b3="B604" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="138 KV" b3="BEL-TRI2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13820</SeqNum>
    <Name>L138.Belmont-Trissler.648</Name>
    <LastEdit Timestamp="2024-06-13T13:15:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISSLER" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="138 KV" b3="BEL-TRI1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13830</SeqNum>
    <Name>L115.Pamplin-RedHouse-SouthCreek.1006</Name>
    <LastEdit Timestamp="2026-03-05T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PAMPLIN" b2="115 KV" b3="100642" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAMPLIN" b2="115 KV" b3="1006C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAMPLIN" b2="115 KV" b3="154T1006" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDHSEDP" b2="115 KV" b3="1006B" />
      <ContingencyEquipment Action="L" Type="LN" b1="STHCREEK" b2="115 KV" b3="1006A" />
      <ContingencyEquipment Action="X" Type="XF" b1="STHCREEK" b2="115 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13860</SeqNum>
    <Name>L138.Page-Bethel-Riverton</Name>
    <LastEdit Timestamp="2024-12-05T16:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BETHEL" b2="138 KV" b3="BET-PAG" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHEL" b2="138 KV" b3="BET-RIVU" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BETHEL" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAGE" b2="138 KV" b3="RVRTON_R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERTON" b2="138 KV" b3="BETHELLU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13870</SeqNum>
    <Name>L138.Bethelboro-Connelsville</Name>
    <LastEdit Timestamp="2024-09-30T14:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BETHELBO" b2="138 KV" b3="BET-CON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHELBO" b2="138 KV" b3="CONNELLS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONNELSV" b2="138 KV" b3="BETHELBO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13880</SeqNum>
    <Name>L138.Bethelboro-Yukon</Name>
    <LastEdit Timestamp="2026-02-10T11:58:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHELBO" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHELBO" b2="138 KV" b3="BET-YUK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="Y13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13900</SeqNum>
    <Name>L345.12 Dresden-935 Kendall.93505-1</Name>
    <LastEdit Timestamp="2025-11-11T08:40:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="6-20" />
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="345 KV" b3="93505_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="BT6-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="BT9-10CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13910</SeqNum>
    <Name>L138.BethelPark-StClair</Name>
    <LastEdit Timestamp="2025-01-15T17:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BETHELPA" b2="138 KV" b3="BET-STC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHELPA" b2="138 KV" b3="ST CLAIR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STCL APS" b2="138 KV" b3="BETHELPA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13920</SeqNum>
    <Name>L138.SouthFayette-StClairAPS</Name>
    <LastEdit Timestamp="2025-03-05T16:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SFAYETTE" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SFAYETTE" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SFAYETTE" b2="138 KV" b3="SFA-STC" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STCL APS" b2="138 KV" b3="SFAYETTE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13930</SeqNum>
    <Name>L138.Cecil-SouthFayette</Name>
    <LastEdit Timestamp="2025-01-15T17:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CECI APS" b2="138 KV" b3="CEC-SFA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CECI APS" b2="138 KV" b3="ST.CLAIR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SFAYETTE" b2="138 KV" b3="CECIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13950</SeqNum>
    <Name>500/138.BlackOak.T3</Name>
    <LastEdit Timestamp="2026-01-23T13:09:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKOAK" b2="138 KV" b3="3XFMRBO3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKOAK" b2="500 KV" b3="B78" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLACKOAK" b2="500 KV" b3="TRAN  3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13960</SeqNum>
    <Name>L138.BlackOak-Junction</Name>
    <LastEdit Timestamp="2026-03-05T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKOAK" b2="138 KV" b3="BO10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKOAK" b2="138 KV" b3="BO9" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKOAK" b2="138 KV" b3="BLA-JUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNCTION" b2="138 KV" b3="BLACKOAK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>13990</SeqNum>
    <Name>L138.Boonsboro-Marlowe</Name>
    <LastEdit Timestamp="2025-12-29T10:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONSBOR" b2="138 KV" b3="MARLOWE" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOONSBOR" b2="138 KV" b3="BOO-MAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARLOWE" b2="138 KV" b3="BOONSBOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14000</SeqNum>
    <Name>230/138.Boonsboro.T5</Name>
    <LastEdit Timestamp="2024-12-02T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONSBOR" b2="138 KV" b3="FROSTOWN" />
      <ContingencyEquipment Action="X" Type="XF" b1="BOONSBOR" b2="230 KV" b3="T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONSBOR" b2="230 KV" b3="T5 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOONSBOR" b2="230 KV" b3="BOO-FRO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14010</SeqNum>
    <Name>L138.Loyalhanna-BrackenJct-Luxor-EastGate-Youngwd</Name>
    <LastEdit Timestamp="2025-01-17T15:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRACKJCT" b2="138 KV" b3="BRA-EAS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EASTGATE" b2="138 KV" b3="BRACYOUN" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTGATE" b2="138 KV" b3="EAS-YOU" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="EASTGATE" b2="138 KV" b3="LUXOSONY" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRACKJCT" b2="138 KV" b3="BRA-LOY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOYALHAN" b2="138 KV" b3="BRACKJCT" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOYALHAN" b2="138 KV" b3="BRACKRES" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRACKJCT" b2="138 KV" b3="BRA-LUX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUXOR" b2="138 KV" b3="BRACKJCT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YOUNGWOO" b2="138 KV" b3="EASTGATE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14030</SeqNum>
    <Name>L138.Luxor-Loyalhanna</Name>
    <LastEdit Timestamp="2025-02-10T13:24:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOYALHAN" b2="138 KV" b3="LUXOR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOYALHAN" b2="138 KV" b3="LUXORRES" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOYALHAN" b2="138 KV" b3="LOY-LUX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUXOR" b2="138 KV" b3="LOYALHAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14040</SeqNum>
    <Name>L138.Butler-CabreyJct-Bredinville-Cabot</Name>
    <LastEdit Timestamp="2025-02-25T19:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BREDINVI" b2="138 KV" b3="CABREJCT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTL APS" b2="138 KV" b3="CABREJCT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BREDINVI" b2="138 KV" b3="BRE-CAB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUTL APS" b2="138 KV" b3="BUT-CAB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CABOT" b2="138 KV" b3="CAB-CAB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14050</SeqNum>
    <Name>L138.Bredinville-Kilgo-McCalmont</Name>
    <LastEdit Timestamp="2025-01-10T12:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BREDINVI" b2="138 KV" b3="BRE-KIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BREDINVI" b2="138 KV" b3="KILGO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KILGO" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KILGO" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="L" Type="LN" b1="KILGO" b2="138 KV" b3="KIL-MCC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCALMON" b2="138 KV" b3="KILGO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14070</SeqNum>
    <Name>L138.ShinnsRun-BarnettsRun.406</Name>
    <LastEdit Timestamp="2025-01-15T18:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BARNETTS" b2="138 KV" b3="BAR-SHI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BARNETTS" b2="138 KV" b3="SHINNDIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHINNSRN" b2="138 KV" b3="BUS TIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14090</SeqNum>
    <Name>L138.Buckhannon-Volga-CorderCrossing-PruntyTown.12</Name>
    <LastEdit Timestamp="2025-09-04T14:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKHANN" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKHANN" b2="138 KV" b3="BUC-VOLG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CORDERCR" b2="138 KV" b3="CORDERCR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORDERCR" b2="138 KV" b3="CS223J" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORDERCR" b2="138 KV" b3="COR-LEER" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEERS_T" b2="138 KV" b3="LEE-LEER" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEERWEST" b2="138 KV" b3="LEE-PRU2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEERWEST" b2="138 KV" b3="LEERW_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORDERCR" b2="138 KV" b3="COR-VOLG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14100</SeqNum>
    <Name>L138.Buckhannon-FrenchCreek.44</Name>
    <LastEdit Timestamp="2025-04-25T16:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKHANN" b2="138 KV" b3="B44" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKHANN" b2="138 KV" b3="BUC-FRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENCHCR" b2="138 KV" b3="BUCKHANN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14110</SeqNum>
    <Name>L138.RiderSS-NationalCarbon-GlenFalls.50</Name>
    <LastEdit Timestamp="2025-06-26T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENFALL" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENFALL" b2="138 KV" b3="GLE-NAT" />
      <ContingencyEquipment Action="L" Type="LN" b1="NATIONAL" b2="138 KV" b3="NAT-RID" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NATIONAL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATIONAL" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDERSS" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDERSS" b2="138 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14120</SeqNum>
    <Name>L138.Buckhan-EBuckhan-Tallmans-RoarngCrk-LoughsLan</Name>
    <LastEdit Timestamp="2025-12-30T11:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKHANN" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKHANN" b2="138 KV" b3="BUC-EBU" />
      <ContingencyEquipment Action="L" Type="LN" b1="EBUCKHAN" b2="138 KV" b3="EBU-TAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EBUCKHAN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUGHSLA" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOUGHSLA" b2="138 KV" b3="LOU-ROR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROARCREK" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROARCREK" b2="138 KV" b3="ROR-TAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TALLMANS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TALLMANS" b2="138 KV" b3="T1 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14140</SeqNum>
    <Name>L138.Houseville-BullCreekJCT-McCalmont-Cabot</Name>
    <LastEdit Timestamp="2026-04-10T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BULLCJCT" b2="138 KV" b3="BUL-CAB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BULLCJCT" b2="138 KV" b3="BUL-HOU" />
      <ContingencyEquipment Action="L" Type="LN" b1="BULLCJCT" b2="138 KV" b3="BUL-MOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="B25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOUSEVIL" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOUSEVIL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCALMON" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCCALMON" b2="138 KV" b3="MCC-MOU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTGATHER" b2="138 KV" b3="MOUNTAIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14160</SeqNum>
    <Name>L138.Butler-Cabot.West</Name>
    <LastEdit Timestamp="2025-03-05T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTL APS" b2="138 KV" b3="CABOTW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUTL APS" b2="138 KV" b3="CABWRES" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUTL APS" b2="138 KV" b3="BUT-CABW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14170</SeqNum>
    <Name>L138.Butler-KarnsCity</Name>
    <LastEdit Timestamp="2025-05-13T10:10:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTL APS" b2="138 KV" b3="B19" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUTL APS" b2="138 KV" b3="BUT-KAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KARNSCIT" b2="138 KV" b3="B73" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14180</SeqNum>
    <Name>L138.Butler-Cabot.East</Name>
    <LastEdit Timestamp="2025-03-05T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUTL APS" b2="138 KV" b3="CABERES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTL APS" b2="138 KV" b3="CABOTE" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUTL APS" b2="138 KV" b3="BUT-CABE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14190</SeqNum>
    <Name>L138.Butler-ShanorManor-Krendale</Name>
    <LastEdit Timestamp="2025-03-24T13:06:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTL APS" b2="138 KV" b3="B31" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUTL APS" b2="138 KV" b3="BUT-SHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KRENDALE" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KRENDALE" b2="138 KV" b3="KRE-SHA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHANORMA" b2="138 KV" b3="T61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14210</SeqNum>
    <Name>500/138.Cabot.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-03-05T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C20" />
      <ContingencyEquipment Action="X" Type="XF" b1="CABOT" b2="500 KV" b3="TRAN  2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="500 KV" b3="XF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14220</SeqNum>
    <Name>500/138.Cabot.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-03-05T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C8" />
      <ContingencyEquipment Action="X" Type="XF" b1="CABOT" b2="500 KV" b3="TRAN  4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="500 KV" b3="XF4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14230</SeqNum>
    <Name>L138.Cabot-LawsonJCT-McCalmont-Fawn</Name>
    <LastEdit Timestamp="2025-09-03T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C5" />
      <ContingencyEquipment Action="L" Type="LN" b1="CABOT" b2="138 KV" b3="CAB-LAW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWN" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAWN" b2="138 KV" b3="FAW-LAW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCALMON" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAWSOJCT" b2="138 KV" b3="LAW-MCC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14240</SeqNum>
    <Name>L138.Cabot-Saxonburg </Name>
    <LastEdit Timestamp="2026-04-10T14:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C18" />
      <ContingencyEquipment Action="L" Type="LN" b1="CABOT" b2="138 KV" b3="CAB-SAX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SAXONBUR" b2="138 KV" b3="T61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14260</SeqNum>
    <Name>L138.LakeLynn-Lardin.2</Name>
    <LastEdit Timestamp="2026-03-05T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAKELYNN" b2="138 KV" b3="LAK-LAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKELYNN" b2="138 KV" b3="LARDIN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARDIN" b2="138 KV" b3="L-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARDIN" b2="138 KV" b3="L-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14300</SeqNum>
    <Name>L230.CarbonCenter-Elko</Name>
    <LastEdit Timestamp="2025-06-05T12:49:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARBONCE" b2="230 KV" b3="T1H" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARBONCE" b2="230 KV" b3="T82" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARBONCE" b2="230 KV" b3="CAR-ELK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELKO" b2="230 KV" b3="CARBONCE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14310</SeqNum>
    <Name>L138.Elko-CarbonCenter-Williamette-PaperCity</Name>
    <LastEdit Timestamp="2025-05-22T13:39:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARBONCE" b2="138 KV" b3="CAR-WIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARBONCE" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARBONCE" b2="138 KV" b3="T71" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARBONCE" b2="138 KV" b3="CAR-ELK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELKO" b2="138 KV" b3="CARBONCE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAPERCIT" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAPERCIT" b2="138 KV" b3="PAP-WIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PAPERCIT" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILLAMET" b2="138 KV" b3="T61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14320</SeqNum>
    <Name>230/138.CarbonCenter.T1</Name>
    <LastEdit Timestamp="2026-03-05T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CARBONCE" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARBONCE" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARBONCE" b2="230 KV" b3="T1H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14330</SeqNum>
    <Name>L138.Garrett-CarlosJct-DansMountain</Name>
    <LastEdit Timestamp="2024-12-23T11:56:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARLOJCT" b2="138 KV" b3="CAR-DAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLOJCT" b2="34.5 KV" b3="T1LSCB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARLOJCT" b2="34.5 KV" b3="T1_LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARLOJCT" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANSMNTN" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANSMNTN" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARLOJCT" b2="138 KV" b3="CAR-GAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARRETT" b2="138 KV" b3="CARLOJCT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14340</SeqNum>
    <Name>L138.Weirton-Carnegie-Tidd.224</Name>
    <LastEdit Timestamp="2025-01-16T15:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARNEGIE" b2="138 KV" b3="CAR-TID" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARNEGIE" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARNEGIE" b2="138 KV" b3="CAR-WEI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEIRTON" b2="138 KV" b3="CARNEGIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14350</SeqNum>
    <Name>L138.Carroll-Catoctin</Name>
    <LastEdit Timestamp="2025-12-18T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARROLL" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARROLL" b2="138 KV" b3="CAR-CAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CATOCTIN" b2="138 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14370</SeqNum>
    <Name>230/138.Carroll.T4</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARROLL" b2="138 KV" b3="B36" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARROLL" b2="230 KV" b3="B41" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARROLL" b2="230 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14380</SeqNum>
    <Name>L138.Catoctin-GarfieldTap-Ringgold</Name>
    <LastEdit Timestamp="2024-10-30T15:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CATOCTIN" b2="138 KV" b3="CAT-GAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CATOCTIN" b2="138 KV" b3="RINGGOLD" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARFLD_T" b2="138 KV" b3="GAR-RIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GARFLD_T" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RINGGOLD" b2="138 KV" b3="CATOCTIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14410</SeqNum>
    <Name>L138.Cecil-Enlow</Name>
    <LastEdit Timestamp="2025-03-05T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CECI APS" b2="138 KV" b3="ENLOW" />
      <ContingencyEquipment Action="L" Type="LN" b1="CECI APS" b2="138 KV" b3="CEC-ENL" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ENLOW" b2="138 KV" b3="CECIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14420</SeqNum>
    <Name>L138.Charleroi-Mitchell</Name>
    <LastEdit Timestamp="2025-01-10T12:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLERO" b2="138 KV" b3="MITCHELL" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLERO" b2="138 KV" b3="CHA-MIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHELL" b2="138 KV" b3="CHARLERO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14430</SeqNum>
    <Name>L138.Charleroi-DryRun-Mitchell</Name>
    <LastEdit Timestamp="2025-01-10T12:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLERO" b2="138 KV" b3="CHA-DRY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLERO" b2="138 KV" b3="DRYRUN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DRYRUN" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="L" Type="LN" b1="DRYRUN" b2="138 KV" b3="DRY-MIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHELL" b2="138 KV" b3="DRYRUN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14450</SeqNum>
    <Name>L138.Charleroi-Gordon</Name>
    <LastEdit Timestamp="2024-05-13T09:46:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLERO" b2="138 KV" b3="GORDON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDON" b2="138 KV" b3="B25" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLERO" b2="138 KV" b3="CHA-GOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14460</SeqNum>
    <Name>L138.Charleroi-UnionJCT-Mitchel-Peters</Name>
    <LastEdit Timestamp="2025-01-10T12:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLERO" b2="138 KV" b3="CHA-UNI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLERO" b2="138 KV" b3="UNIONJCT" />
      <ContingencyEquipment Action="L" Type="LN" b1="MITCHELL" b2="138 KV" b3="MIT-UNI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHELL" b2="138 KV" b3="UNIONJCT" />
      <ContingencyEquipment Action="L" Type="LN" b1="PETERS" b2="138 KV" b3="PET-UNI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERS" b2="138 KV" b3="UNIONJCT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14470</SeqNum>
    <Name>L138.Charleroi-Vanceville-WashingtonAPS</Name>
    <LastEdit Timestamp="2025-02-28T12:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLERO" b2="138 KV" b3="CHA-VAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLERO" b2="138 KV" b3="VANCEVIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VANCEVIL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="VANCEVIL" b2="138 KV" b3="VAN-WAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WASH APS" b2="138 KV" b3="VANCEVIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14510</SeqNum>
    <Name>L138.Charleroi-Yukon</Name>
    <LastEdit Timestamp="2025-07-25T16:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLERO" b2="138 KV" b3="CHA-YUK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLERO" b2="138 KV" b3="YUKON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="Y11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14520</SeqNum>
    <Name>L138.CherryRun-Warfordsburg-McConnelsburg</Name>
    <LastEdit Timestamp="2025-12-11T14:25:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHERRYRN" b2="138 KV" b3="CHE-WAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHERRYRN" b2="138 KV" b3="WARFORDS" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCCONNEL" b2="138 KV" b3="MCC-WAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCONNEL" b2="138 KV" b3="WARFORDS" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WARFORDS" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WARFORDS" b2="34.5 KV" b3="HE1_LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WARFORDS" b2="34.5 KV" b3="MCC_LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WARFORDS" b2="34.5 KV" b3="T52" />
      <ContingencyEquipment Action="X" Type="XF" b1="WARFORDS" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14530</SeqNum>
    <Name>L138.CherryRun-Morgan</Name>
    <LastEdit Timestamp="2025-01-13T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHERRYRN" b2="138 KV" b3="CHE-MOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHERRYRN" b2="138 KV" b3="MORGAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MORGAN" b2="138 KV" b3="CHERRYRN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14550</SeqNum>
    <Name>L138.Washington-TimberLake-DutchFork</Name>
    <LastEdit Timestamp="2025-08-25T12:30:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DUTCHFOR" b2="138 KV" b3="DUT-TIMB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUTCHFOR" b2="138 KV" b3="WASHAPS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIMBERLA" b2="138 KV" b3="LD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TIMBERLA" b2="138 KV" b3="TIM-WASH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WASH APS" b2="138 KV" b3="DUTCHFOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14560</SeqNum>
    <Name>L138.Connellsville-StoneJCT-KingFarm-IronBridge</Name>
    <LastEdit Timestamp="2024-05-21T15:08:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONNELSV" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONBRID" b2="138 KV" b3="B40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGFARM" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KINGFARM" b2="138 KV" b3="T61 DIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONNELSV" b2="138 KV" b3="CON-STO" />
      <ContingencyEquipment Action="L" Type="LN" b1="IRONBRID" b2="138 KV" b3="IRO-STO" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGFARM" b2="138 KV" b3="KIN-STO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14570</SeqNum>
    <Name>L138.Corner-Layman-WolfCreek.86</Name>
    <LastEdit Timestamp="2025-01-16T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORNER" b2="138 KV" b3="COR-LAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORNER" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CORNER" b2="138 KV" b3="LAYMON1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAYMAN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAYMAN" b2="138 KV" b3="LAY-WOL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFCREE" b2="138 KV" b3="N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14580</SeqNum>
    <Name>L138.Corner-RiverView</Name>
    <LastEdit Timestamp="2026-03-05T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORNER" b2="138 KV" b3="COR-RIV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORNER" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RIVERVIE" b2="138 KV" b3="1048MOAB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIE" b2="138 KV" b3="646" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14590</SeqNum>
    <Name>L138.Corner-Washington2</Name>
    <LastEdit Timestamp="2026-03-05T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORNER" b2="138 KV" b3="COR-WAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORNER" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CORNER" b2="138 KV" b3="WASHIRES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WASH2APS" b2="138 KV" b3="CORNER" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WASH2APS" b2="138 KV" b3="CORNERES" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14610</SeqNum>
    <Name>L138.Crupperneck-Nettie-GrassyFalls</Name>
    <LastEdit Timestamp="2025-03-31T17:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRUPPERN" b2="138 KV" b3="CRU-NET" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRUPPERN" b2="138 KV" b3="GRASFL_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRASSYFA" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRASSYFA" b2="138 KV" b3="GRA-NET" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NETTIE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14620</SeqNum>
    <Name>L138.Cumberland-Ridgeley</Name>
    <LastEdit Timestamp="2026-01-27T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB APS" b2="138 KV" b3="RIDGELEY" />
      <ContingencyEquipment Action="L" Type="LN" b1="CUMB APS" b2="138 KV" b3="CUM-RID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGELEY" b2="138 KV" b3="CUMBERLA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14640</SeqNum>
    <Name>L230.Damascus-Montgomery.220</Name>
    <LastEdit Timestamp="2025-11-21T15:33:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAMASCUS" b2="230 KV" b3="BUSTIEBA" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAMASCUS" b2="230 KV" b3="DAM-MON" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAMASCUS" b2="230 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTGOME" b2="230 KV" b3="DAMASCUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14650</SeqNum>
    <Name>L230.Damascus-MtAiry.213</Name>
    <LastEdit Timestamp="2025-03-14T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="DAMASCUS" b2="230 KV" b3="MTAIRY" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAMASCUS" b2="230 KV" b3="DAM-MTA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTAIRY" b2="230 KV" b3="DAMASCUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14660</SeqNum>
    <Name>L138.FairView-DentsRun-EastRun-Margaret-GlenFall</Name>
    <LastEdit Timestamp="2024-05-15T09:40:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DENTSRUN" b2="138 KV" b3="DEN-EAS" />
      <ContingencyEquipment Action="L" Type="LN" b1="DENTSRUN" b2="138 KV" b3="DEN-FAI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENTSRUN" b2="138 KV" b3="DENTS CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DENTSRUN" b2="138 KV" b3="DENTSRUN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTRUN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAIR APS" b2="138 KV" b3="DENTSRES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIR APS" b2="138 KV" b3="DENTSRUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENFALL" b2="138 KV" b3="B26" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENFALL" b2="138 KV" b3="GLE-HAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARSNRES" b2="138 KV" b3="HAR-ROB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARSNRES" b2="138 KV" b3="SS" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTRUN" b2="138 KV" b3="EAS-MAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARSNRES" b2="138 KV" b3="HAR-MAR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARGARET" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARGARET" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROBERTS" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14670</SeqNum>
    <Name>L138.DoubleTollGate-Greenwood.DRB-2</Name>
    <LastEdit Timestamp="2025-11-17T15:37:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBLETO" b2="138 KV" b3="DOU-GRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBLETO" b2="138 KV" b3="GREENWOO" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENWOO" b2="138 KV" b3="1339" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14680</SeqNum>
    <Name>L138.MeadowBrook-DoubleTollGate.1MBG</Name>
    <LastEdit Timestamp="2025-08-25T11:35:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBLETO" b2="138 KV" b3="DOU-MEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBLETO" b2="138 KV" b3="MEADOWB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14690</SeqNum>
    <Name>L138.MeadowBrook-DoubleTollGate.2MDT</Name>
    <LastEdit Timestamp="2025-03-05T16:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBLETO" b2="138 KV" b3="DOU-MEA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBLETO" b2="138 KV" b3="MEADOWB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14710</SeqNum>
    <Name>L138.DoubleTollGate-Riverton</Name>
    <LastEdit Timestamp="2026-01-16T13:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBLETO" b2="138 KV" b3="DOU-RIV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBLETO" b2="138 KV" b3="RIVERTON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERTON" b2="138 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14720</SeqNum>
    <Name>L500.Doubs-GooseCreek.514</Name>
    <LastEdit Timestamp="2026-03-05T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="CB 50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="CB 52" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBS" b2="500 KV" b3="DOU-GOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRE" b2="500 KV" b3="51482" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRE" b2="500 KV" b3="514T595" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14740</SeqNum>
    <Name>500/230.Doubs.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-12T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DOUBS" b2="500 KV" b3="500-1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DOUBS" b2="500 KV" b3="CAP4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ10 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="DL61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14750</SeqNum>
    <Name>500/230.Doubs.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-12T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DOUBS" b2="500 KV" b3="500-3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DOUBS" b2="500 KV" b3="CAP4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ12 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="DL61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="XF3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14770</SeqNum>
    <Name>500/230.Doubs.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-12T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="2CAPDL59" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOUBS" b2="500 KV" b3="500-2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DOUBS" b2="500 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ13 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="XF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14780</SeqNum>
    <Name>500/230.Doubs.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-12T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="2CAPDL59" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOUBS" b2="500 KV" b3="500-4" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DOUBS" b2="500 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ11 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="XF4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14790</SeqNum>
    <Name>L138.Doubs-Lovettsville-Millville</Name>
    <LastEdit Timestamp="2025-01-14T15:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBS" b2="138 KV" b3="DOU-LOV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="138 KV" b3="LOVETTSV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOVETTSV" b2="138 KV" b3="LOVE_DVP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOVETTSV" b2="138 KV" b3="LOV_DVP2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOVETTSV" b2="138 KV" b3="LOV-MIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLVILL" b2="138 KV" b3="LOVETTSV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14830</SeqNum>
    <Name>L230.Doubs-LimeKiln.207</Name>
    <LastEdit Timestamp="2025-01-13T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ15 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ16 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBS" b2="230 KV" b3="DOU-LIM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="230 KV" b3="DOUBS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14850</SeqNum>
    <Name>L230.Doubs-Frostown-Boonsboro-Ringold.202</Name>
    <LastEdit Timestamp="2025-04-08T10:12:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONSBOR" b2="138 KV" b3="FROSTOWN" />
      <ContingencyEquipment Action="X" Type="XF" b1="BOONSBOR" b2="230 KV" b3="T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONSBOR" b2="230 KV" b3="T5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ6 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOONSBOR" b2="230 KV" b3="BOO-FRO" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBS" b2="230 KV" b3="DOU-FRO" />
      <ContingencyEquipment Action="L" Type="LN" b1="FROSTOWN" b2="230 KV" b3="FRO-RIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RINGGOLD" b2="230 KV" b3="FROSTOWN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14860</SeqNum>
    <Name>230/138.Doubs.TX6</Name>
    <LastEdit Timestamp="2024-06-13T08:55:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="138 KV" b3="B80" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ8 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOUBS" b2="230 KV" b3="TRAN_6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14880</SeqNum>
    <Name>L138.Dupont-GEPlastics-Washington2</Name>
    <LastEdit Timestamp="2024-11-20T10:57:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPONT" b2="138 KV" b3="B94" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUPONT" b2="138 KV" b3="DUP-GEP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DUPONT" b2="138 KV" b3="W94_BYP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GEPLASTI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEPLASTI" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GEPLASTI" b2="138 KV" b3="GEP-WAS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WASH2APS" b2="138 KV" b3="GEPLASTI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14890</SeqNum>
    <Name>L230.Eaglehead-Monocacy.208</Name>
    <LastEdit Timestamp="2025-03-14T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EAGLEHEA" b2="230 KV" b3="EAG-MON" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EAGLEHEA" b2="230 KV" b3="MONOCACY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONOCACY" b2="230 KV" b3="EAGLEHEA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14900</SeqNum>
    <Name>L230.Eaglehead-NewMarket.209</Name>
    <LastEdit Timestamp="2025-03-14T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EAGLEHEA" b2="230 KV" b3="EAG-NEW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EAGLEHEA" b2="230 KV" b3="NEWMARKE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NEWMARKE" b2="230 KV" b3="EAGLEHEA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14910</SeqNum>
    <Name>L138.Edgelawn-GoffRun.632</Name>
    <LastEdit Timestamp="2025-01-13T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EDGELAWN" b2="138 KV" b3="EDG-GOF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGELAWN" b2="138 KV" b3="GOFFRUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOFFRUN" b2="138 KV" b3="B632" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14920</SeqNum>
    <Name>L138.Edgelawn-Trissler.90</Name>
    <LastEdit Timestamp="2025-10-29T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGELAWN" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDGELAWN" b2="138 KV" b3="EDG-TRI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISSLER" b2="138 KV" b3="B90" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14930</SeqNum>
    <Name>L138.LoyalHan-Edgewater-Vasco-EthelSpr-SocialHall</Name>
    <LastEdit Timestamp="2024-10-03T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDGEWATE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ETHELSPR" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ETHELSPR" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEWATE" b2="138 KV" b3="EDG-LOY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOYALHAN" b2="138 KV" b3="EDGEWATE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOYALHAN" b2="138 KV" b3="EDGEWRES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOCIALHA" b2="138 KV" b3="VASCOTAP" />
      <ContingencyEquipment Action="L" Type="LN" b1="ETHELSPR" b2="138 KV" b3="ETH-VAS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VASCO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEWATE" b2="138 KV" b3="EDG-VAS" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOCIALHA" b2="138 KV" b3="SOC-VAS" />
      <ContingencyEquipment Action="L" Type="LN" b1="VASCO" b2="138 KV" b3="VAS-VAS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14940</SeqNum>
    <Name>L138.EHagerstown-Ringgold</Name>
    <LastEdit Timestamp="2025-01-13T15:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="EHAGERST" b2="138 KV" b3="RINGGOLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RINGGOLD" b2="138 KV" b3="EASTHAGE" />
      <ContingencyEquipment Action="L" Type="LN" b1="EHAGERST" b2="138 KV" b3="EHA-RIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14950</SeqNum>
    <Name>L138.PruntyTown-WhitehallJct-Mcalpin.36</Name>
    <LastEdit Timestamp="2025-01-15T18:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELDORA" b2="138 KV" b3="ELD-WHI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELDORA" b2="138 KV" b3="WHITEJCT" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCALPIN" b2="138 KV" b3="MCA-WHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCALPIN" b2="138 KV" b3="WHITEJCT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="P4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="P5" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRUNTYTO" b2="138 KV" b3="PRU-WHI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14960</SeqNum>
    <Name>L138.Elko-RidgeWayAPS</Name>
    <LastEdit Timestamp="2025-02-28T12:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELKO" b2="138 KV" b3="RIDGWAY" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKO" b2="138 KV" b3="ELK-RID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDG APS" b2="138 KV" b3="ELKO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14970</SeqNum>
    <Name>L138.Brookville-SquabHollow</Name>
    <LastEdit Timestamp="2025-02-25T19:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BROOKVIL" b2="138 KV" b3="2 TX" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKVIL" b2="138 KV" b3="BRO-SQU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKVIL" b2="138 KV" b3="BSSEC138" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SQUABHOL" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SQUABHOL" b2="138 KV" b3="B16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14980</SeqNum>
    <Name>L230.Elko-Quehanna-Moshannon</Name>
    <LastEdit Timestamp="2024-11-06T03:31:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELKO" b2="230 KV" b3="QUEHANNA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSHANON" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSHANON" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKO" b2="230 KV" b3="ELK-QUE" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOSHANON" b2="230 KV" b3="MOS-QUE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="QUEHANNA" b2="230 KV" b3="T81" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>14990</SeqNum>
    <Name>230/138.Elko.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-19T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELKO" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELKO" b2="230 KV" b3="T1 DIS" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELKO" b2="230 KV" b3="TRAN  1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15000</SeqNum>
    <Name>L138.NorthFayette-Enlow</Name>
    <LastEdit Timestamp="2025-02-10T13:38:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ENLOW" b2="138 KV" b3="ENL-NFA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ENLOW" b2="138 KV" b3="N FAYETT" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NFAYETTE" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NFAYETTE" b2="138 KV" b3="CAP1 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NFAYETTE" b2="138 KV" b3="ENLOW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15020</SeqNum>
    <Name>L138.Carbondale-KanawhaRiver</Name>
    <LastEdit Timestamp="2026-05-20T17:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARBOND2" b2="138 KV" b3="CAR-KAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARBOND2" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="138 KV" b3="P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15060</SeqNum>
    <Name>L138.Fawn-Gobain</Name>
    <LastEdit Timestamp="2025-10-24T12:59:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWN" b2="138 KV" b3="B25" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAWN" b2="138 KV" b3="FAW-GOB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOBAIN" b2="138 KV" b3="B47" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15090</SeqNum>
    <Name>L138.FranklinAPS-WashingtonAPS</Name>
    <LastEdit Timestamp="2025-03-05T16:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FRAN APS" b2="138 KV" b3="WASHINGT" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRAN APS" b2="138 KV" b3="FRA-WAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WASH APS" b2="138 KV" b3="FRANKLIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15100</SeqNum>
    <Name>L138.Pursley-Whiteley</Name>
    <LastEdit Timestamp="2026-03-05T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PURSLEY" b2="138 KV" b3="PUR-WHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PURSLEY" b2="138 KV" b3="WHITELEY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITELEY" b2="138 KV" b3="PURS CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15110</SeqNum>
    <Name>L230.Frederick-McCain.233</Name>
    <LastEdit Timestamp="2025-04-25T17:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FREDERIC" b2="230 KV" b3="BUSTIEA" />
      <ContingencyEquipment Action="L" Type="LN" b1="FREDERIC" b2="230 KV" b3="FRE-MCC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FREDERIC" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCAIN" b2="230 KV" b3="B233" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15120</SeqNum>
    <Name>L230.Frederick-Monocacy.234</Name>
    <LastEdit Timestamp="2025-03-11T06:23:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FREDERIC" b2="230 KV" b3="BUSTIEA" />
      <ContingencyEquipment Action="L" Type="LN" b1="FREDERIC" b2="230 KV" b3="FRE-MONO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FREDERIC" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREDERIC" b2="230 KV" b3="T2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREDERIC" b2="230 KV" b3="T5CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONOCACY" b2="230 KV" b3="FREDERIK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15130</SeqNum>
    <Name>L138.FrenchCreek-Heaters-Sutton.52</Name>
    <LastEdit Timestamp="2025-08-25T12:33:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENCHCR" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRENCHCR" b2="138 KV" b3="FRE-HEA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HEATERS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HEATERS" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUTTON" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEATERS" b2="138 KV" b3="HEA-SUT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15140</SeqNum>
    <Name>L138.FrenchCreek-Pickens.56</Name>
    <LastEdit Timestamp="2025-11-24T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENCHCR" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRENCHCR" b2="138 KV" b3="FRE-PIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PICKENS" b2="138 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15150</SeqNum>
    <Name>L138.FrenchsMill-Junction.JST1</Name>
    <LastEdit Timestamp="2025-08-22T15:41:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENCHSM" b2="34.5 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENCHSM" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="X" Type="XF" b1="FRENCHSM" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNCTION" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRENCHSM" b2="138 KV" b3="FRE-JUN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15160</SeqNum>
    <Name>L138.FrenchsMill-Hampshire-Ridgeley</Name>
    <LastEdit Timestamp="2023-08-24T16:02:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENCHSM" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRENCHSM" b2="138 KV" b3="FRE-HAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENCHSM" b2="34.5 KV" b3="T2LCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FRENCHSM" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMPSHIR" b2="138 KV" b3="CS1323" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMPSHIR" b2="138 KV" b3="CS1324" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAMPSHIR" b2="138 KV" b3="HAM-RID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGELEY" b2="138 KV" b3="HAMPSHIR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15180</SeqNum>
    <Name>FtMartin.GEN1</Name>
    <LastEdit Timestamp="2025-03-05T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FTMARTIN" b2="500 KV" b3="FL1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FTMARTIN" b2="500 KV" b3="FL2 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FTMARTIN" b2="22 KV" b3="GEN  1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FTMARTIN" b2="22 KV" b3="SS1 LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="FTMARTIN" b2="500 KV" b3="TRAN  1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15190</SeqNum>
    <Name>FtMartin.GEN2</Name>
    <LastEdit Timestamp="2025-08-25T11:59:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FTMARTIN" b2="500 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FTMARTIN" b2="500 KV" b3="FL5 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FTMARTIN" b2="22 KV" b3="GEN  2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FTMARTIN" b2="22 KV" b3="SS2 LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="FTMARTIN" b2="500 KV" b3="TRAN  2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15200</SeqNum>
    <Name>L500.NorthLongview-FtMartin.523</Name>
    <LastEdit Timestamp="2025-06-04T13:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FTMARTIN" b2="500 KV" b3="FL7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FTMARTIN" b2="500 KV" b3="FL8 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="FTMARTIN" b2="500 KV" b3="FTM-NLO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLONGVW" b2="500 KV" b3="NLVL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLONGVW" b2="500 KV" b3="NLVL3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15210</SeqNum>
    <Name>L500.FtMartin-Pruntytown.508</Name>
    <LastEdit Timestamp="2025-08-25T10:46:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FTMARTIN" b2="500 KV" b3="B9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FTMARTIN" b2="500 KV" b3="FL8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="500 KV" b3="B122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="500 KV" b3="B123" />
      <ContingencyEquipment Action="L" Type="LN" b1="FTMARTIN" b2="500 KV" b3="FTM-PRU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15220</SeqNum>
    <Name>L500.Hatfield-Ronco.538</Name>
    <LastEdit Timestamp="2025-08-25T12:19:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HATFIELD" b2="500 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATFIELD" b2="500 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="HATFIELD" b2="500 KV" b3="HAT-RON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RONCO" b2="500 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RONCO" b2="500 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15230</SeqNum>
    <Name>L500.FtMartin-Ronco.516</Name>
    <LastEdit Timestamp="2025-08-25T12:02:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FTMARTIN" b2="500 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FTMARTIN" b2="500 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="FTMARTIN" b2="500 KV" b3="FTM-RON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RONCO" b2="500 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RONCO" b2="500 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15240</SeqNum>
    <Name>L138.Lardin-GatesHill</Name>
    <LastEdit Timestamp="2025-03-05T16:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GATESHIL" b2="138 KV" b3="GAT-LAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GATESHIL" b2="138 KV" b3="LARDIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARDIN" b2="138 KV" b3="L-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARDIN" b2="138 KV" b3="L-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15260</SeqNum>
    <Name>L138.GlenFalls-OakMound</Name>
    <LastEdit Timestamp="2025-05-08T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENFALL" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENFALL" b2="138 KV" b3="GLE-OAK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKMOUND" b2="138 KV" b3="GLEN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15270</SeqNum>
    <Name>L500.Freedom-Shickshinny&amp;Freedom.CC</Name>
    <LastEdit Timestamp="2025-06-04T13:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEDOM2" b2="500 KV" b3="11ABA" />
      <ContingencyEquipment Action="X" Type="XF" b1="FREEDOM2" b2="500 KV" b3="11BAT01" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEDOM2" b2="500 KV" b3="21ABA" />
      <ContingencyEquipment Action="X" Type="XF" b1="FREEDOM2" b2="500 KV" b3="21BAT01" />
      <ContingencyEquipment Action="L" Type="LN" b1="FREEDOM2" b2="500 KV" b3="FREE-SHI" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FREEDOM2" b2="24 KV" b3="UNIT11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FREEDOM2" b2="24 KV" b3="UNIT21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHICKSHI" b2="500 KV" b3="FRDM E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHICKSHI" b2="500 KV" b3="FRDM W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15280</SeqNum>
    <Name>L138.Lamberton-MountWood-Trissler</Name>
    <LastEdit Timestamp="2026-03-30T18:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAMBERTO" b2="138 KV" b3="LAM-MTW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMBERTO" b2="138 KV" b3="MNTWOOD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTWOOD" b2="138 KV" b3="MTW-TRI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTWOOD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISSLER" b2="138 KV" b3="B650" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15290</SeqNum>
    <Name>L138.GlenFalls-Mcalpin</Name>
    <LastEdit Timestamp="2026-01-27T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENFALL" b2="138 KV" b3="B30" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENFALL" b2="138 KV" b3="GLE-MCA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MCALPIN" b2="138 KV" b3="GLENFALL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15300</SeqNum>
    <Name>L138.Glenville-Grantsville-GoffRun.308</Name>
    <LastEdit Timestamp="2025-05-08T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENVILL" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENVILL" b2="138 KV" b3="GLE-GRA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLENVILL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOFFRUN" b2="138 KV" b3="B308" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOFFRUN" b2="138 KV" b3="GOF-GRA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRANTSVI" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15310</SeqNum>
    <Name>L138.Glenville-SandyFork-Weston</Name>
    <LastEdit Timestamp="2025-05-08T18:44:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENVILL" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GLENVILL" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENVILL" b2="138 KV" b3="CS3" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENVILL" b2="138 KV" b3="GLE-SAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SANDFTAP" b2="138 KV" b3="LOAD 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SANDFTAP" b2="138 KV" b3="SAN-WES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTON" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WESTON" b2="138 KV" b3="CAP 01" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTON" b2="138 KV" b3="CAP1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTON" b2="138 KV" b3="CS184J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15320</SeqNum>
    <Name>L138.Gobain-PittsburghMills</Name>
    <LastEdit Timestamp="2025-10-21T13:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOBAIN" b2="138 KV" b3="B48" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOBAIN" b2="138 KV" b3="GOB-PIT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOBAIN" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOBAIN" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PITTMILL" b2="138 KV" b3="BUSTIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15340</SeqNum>
    <Name>L138.Gore-StoneWall</Name>
    <LastEdit Timestamp="2025-07-10T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GORE APS" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="L" Type="LN" b1="GORE APS" b2="138 KV" b3="GOR-STO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STONEWAL" b2="138 KV" b3="GORE APS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15350</SeqNum>
    <Name>L138.Gore-Hampshire-MeadowBrook</Name>
    <LastEdit Timestamp="2020-10-19T15:32:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GORE APS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GORE APS" b2="138 KV" b3="GOR-HAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMPSHIR" b2="138 KV" b3="CS1323" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMPSHIR" b2="138 KV" b3="CS1324" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAMPSHIR" b2="138 KV" b3="HAM-MEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15370</SeqNum>
    <Name>L138.Gorsuch-HarmarHill-Goodrich-Devola</Name>
    <LastEdit Timestamp="2025-05-02T13:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEVOLA" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEVOLA" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEVOLA" b2="138 KV" b3="DEV-GOOD" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOODRICH" b2="138 KV" b3="GOO-HAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOODRICH" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOODRICH" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORSUCH" b2="138 KV" b3="BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORSUCH" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GORSUCH" b2="138 KV" b3="CAPB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GORSUCH" b2="138 KV" b3="GOR-HAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARMARHI" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15380</SeqNum>
    <Name>L138.Gorsuch-Riverview</Name>
    <LastEdit Timestamp="2026-03-05T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GORSUCH" b2="138 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORSUCH" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GORSUCH" b2="138 KV" b3="CAPA" />
      <ContingencyEquipment Action="L" Type="LN" b1="GORSUCH" b2="138 KV" b3="GOR-RIV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIE" b2="138 KV" b3="644" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15390</SeqNum>
    <Name>L138.GrandPoint-CiderPress-Guilford</Name>
    <LastEdit Timestamp="2025-07-18T13:17:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CIDERPR" b2="138 KV" b3="CID-GUIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CIDERPR" b2="138 KV" b3="CIDRPRLD" />
      <ContingencyEquipment Action="L" Type="LN" b1="CIDERPR" b2="138 KV" b3="CID-GRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDPT" b2="138 KV" b3="GUILFORD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUILFORD" b2="138 KV" b3="GRANDPOI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15400</SeqNum>
    <Name>Guilford.Gen12</Name>
    <LastEdit Timestamp="2026-03-12T10:05:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GUILFORD" b2="138 KV" b3="G12 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUILFORD" b2="138 KV" b3="G12GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUILFORD" b2="13.8 KV" b3="GEN12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15410</SeqNum>
    <Name>Guilford.Gen13</Name>
    <LastEdit Timestamp="2026-03-12T10:39:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GUILFORD" b2="138 KV" b3="G13 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUILFORD" b2="138 KV" b3="G13GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUILFORD" b2="13.8 KV" b3="GEN13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15430</SeqNum>
    <Name>L138.Guilford-TexasEast6-McDowell</Name>
    <LastEdit Timestamp="2026-01-09T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GUILFORD" b2="138 KV" b3="B126" />
      <ContingencyEquipment Action="L" Type="LN" b1="GUILFORD" b2="138 KV" b3="GUI-TEX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCDOWELL" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCDOWELL" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCDOWELL" b2="138 KV" b3="MCD-TEXA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TEXASEA6" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15470</SeqNum>
    <Name>L138.Hardy-Junction.JUH1</Name>
    <LastEdit Timestamp="2025-05-01T10:00:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDY" b2="138 KV" b3="B32" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDY" b2="138 KV" b3="HAR-JUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNCTION" b2="138 KV" b3="HARDY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15480</SeqNum>
    <Name>L138.Hardy-NorthPetersburg.JUH2</Name>
    <LastEdit Timestamp="2025-01-15T18:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARDY" b2="138 KV" b3="A1328" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HARDY" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDY" b2="138 KV" b3="CAP2 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDY" b2="138 KV" b3="HAR-NPE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPETERSB" b2="138 KV" b3="HARDY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15490</SeqNum>
    <Name>Harrison.U1</Name>
    <LastEdit Timestamp="2025-01-13T14:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="HARR APS" b2="20 KV" b3="GEN  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR APS" b2="500 KV" b3="HL1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR APS" b2="500 KV" b3="HL2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARR APS" b2="20 KV" b3="SS1 LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARR APS" b2="500 KV" b3="TRAN  1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15500</SeqNum>
    <Name>Harrison.U2 </Name>
    <LastEdit Timestamp="2025-01-13T14:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="HARR APS" b2="20 KV" b3="GEN  2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR APS" b2="500 KV" b3="HL4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR APS" b2="500 KV" b3="HL5 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARR APS" b2="20 KV" b3="SS2 LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARR APS" b2="500 KV" b3="TRAN  2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15510</SeqNum>
    <Name>Harrison.U3</Name>
    <LastEdit Timestamp="2025-01-13T14:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="HARR APS" b2="20 KV" b3="GEN  3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR APS" b2="500 KV" b3="HL7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR APS" b2="500 KV" b3="HL8 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARR APS" b2="20 KV" b3="SS3 LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARR APS" b2="500 KV" b3="TRAN  3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15520</SeqNum>
    <Name>L500.Harrison-WylieRidge.530</Name>
    <LastEdit Timestamp="2025-10-22T14:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR APS" b2="500 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR APS" b2="500 KV" b3="HL10 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARR APS" b2="500 KV" b3="HAR-WYL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="500 KV" b3="WL1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="500 KV" b3="WL2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15540</SeqNum>
    <Name>L138.WhiteValley-HarrisonCity</Name>
    <LastEdit Timestamp="2025-01-17T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HARRCITY" b2="138 KV" b3="HAR-WHI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARRCITY" b2="138 KV" b3="WHITEVAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEVAL" b2="138 KV" b3="HARRCITY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15550</SeqNum>
    <Name>L138.Harwick-Houseville</Name>
    <LastEdit Timestamp="2026-04-10T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWICK" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARWICK" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOUSEVIL" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARWICK" b2="138 KV" b3="HAR-HOU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOUSEVIL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15560</SeqNum>
    <Name>L138.Harwick-Springdale</Name>
    <LastEdit Timestamp="2025-12-29T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HARWICK" b2="138 KV" b3="HAR-SPR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARWICK" b2="138 KV" b3="SPRINGDA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="HARWICK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15570</SeqNum>
    <Name>L500.Hatfield-RhodesLane.518</Name>
    <LastEdit Timestamp="2025-08-26T17:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HATFIELD" b2="500 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATFIELD" b2="500 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="HATFIELD" b2="500 KV" b3="HAT-RHO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RHODESLN" b2="500 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RHODESLN" b2="500 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15580</SeqNum>
    <Name>L500.RhodesLane-WestMoreland &amp; WMorelnd.CC</Name>
    <LastEdit Timestamp="2026-01-27T10:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RHODESLN" b2="500 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RHODESLN" b2="500 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="RHODESLN" b2="500 KV" b3="RHO-WMO" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WMORELND" b2="20 KV" b3="CT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WMORELND" b2="20 KV" b3="CT2" />
      <ContingencyEquipment Action="X" Type="XF" b1="WMORELND" b2="500 KV" b3="CTG1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WMORELND" b2="500 KV" b3="CTG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMORELND" b2="500 KV" b3="RHODES" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WMORELND" b2="20 KV" b3="STG" />
      <ContingencyEquipment Action="X" Type="XF" b1="WMORELND" b2="500 KV" b3="STG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15630</SeqNum>
    <Name>L138.Huntingdon-Springdale</Name>
    <LastEdit Timestamp="2025-12-29T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTINGD" b2="138 KV" b3="HUN-SPR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HUNTINGD" b2="138 KV" b3="SPRINGDA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="HUNTINGD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15640</SeqNum>
    <Name>L138.Inwood-SpecksRun-Stonewall</Name>
    <LastEdit Timestamp="2024-11-20T10:57:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="INWOOD" b2="138 KV" b3="1351" />
      <ContingencyEquipment Action="L" Type="LN" b1="INWOOD" b2="138 KV" b3="INW-SPEC" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPECKSRN" b2="138 KV" b3="SPE-STOE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STONEWAL" b2="138 KV" b3="INWOOD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15660</SeqNum>
    <Name>L138.OakGrove-JohnsJCT-SVienna-JohnsMan-Parkersb</Name>
    <LastEdit Timestamp="2025-08-06T13:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JOHNSMAN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSMAN" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKG APS" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKG APS" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSJCT" b2="138 KV" b3="JOH-OAK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARKERSB" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSJCT" b2="138 KV" b3="JOH-PAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSMAN" b2="138 KV" b3="JMA-SVI" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSJCT" b2="138 KV" b3="JOH-SVI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SVIENNA" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15670</SeqNum>
    <Name>L138.Parkersburg-JugRun-Trissler.612</Name>
    <LastEdit Timestamp="2026-01-09T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JUGRUN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARKERSB" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUGRUN" b2="138 KV" b3="JUG-PAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISSLER" b2="138 KV" b3="B612" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUGRUN" b2="138 KV" b3="JUG-TRI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15680</SeqNum>
    <Name>L138.Junction-ParrRun.AJ-4</Name>
    <LastEdit Timestamp="2025-03-05T16:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNCTION" b2="138 KV" b3="PARRRUN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PARRRUN" b2="138 KV" b3="A1307" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNCTION" b2="138 KV" b3="JUN-PAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15690</SeqNum>
    <Name>L138.Kearneysville-Opequon</Name>
    <LastEdit Timestamp="2025-03-05T16:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEARNEYS" b2="138 KV" b3="OPEQUON" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEARNEYS" b2="138 KV" b3="KEA-OPE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPEQUON" b2="138 KV" b3="KEARNEYS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15700</SeqNum>
    <Name>L138.Keisters-Krendale</Name>
    <LastEdit Timestamp="2025-03-05T16:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEISTERS" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEISTERS" b2="138 KV" b3="KEI-KRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KRENDALE" b2="138 KV" b3="KEISTERS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15720</SeqNum>
    <Name>L138.KiskiValley-Vandergrift</Name>
    <LastEdit Timestamp="2025-08-25T12:34:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KISKIVAL" b2="138 KV" b3="B28" />
      <ContingencyEquipment Action="L" Type="LN" b1="KISKIVAL" b2="138 KV" b3="KIS-VAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VANDERGR" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15730</SeqNum>
    <Name>L138.KiskiValley-NorthWashington</Name>
    <LastEdit Timestamp="2025-01-14T15:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KISKIVAL" b2="138 KV" b3="KIS-NWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KISKIVAL" b2="138 KV" b3="N WASHIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NWASHING" b2="138 KV" b3="T61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15740</SeqNum>
    <Name>L138.MeadowBrook-KlinesMill-Riverton.MRV</Name>
    <LastEdit Timestamp="2025-01-15T18:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KLINESMI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KLINESMI" b2="138 KV" b3="KLI-MEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD18" />
      <ContingencyEquipment Action="L" Type="LN" b1="KLINESMI" b2="138 KV" b3="KLI-RIV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERTON" b2="138 KV" b3="KLINESMI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15750</SeqNum>
    <Name>L138.Krendale-RozcFarm-Sen-MrkWst-Zelienople-Maple</Name>
    <LastEdit Timestamp="2025-10-10T13:07:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KRENDALE" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="KRENDALE" b2="138 KV" b3="KRE-SEN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KRENDALE" b2="138 KV" b3="SENECA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLEOE" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLEOE" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAPLEOE" b2="138 KV" b3="MAP-ZEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARKWEST" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARKWEST" b2="138 KV" b3="LDTR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARKWEST" b2="138 KV" b3="LDTR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARKWEST" b2="138 KV" b3="MAR-MAR3" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARKWEST" b2="138 KV" b3="MAR-SEN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARKWST2" b2="138 KV" b3="MARKWST2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROZICFRM" b2="138 KV" b3="A720" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROZICFRM" b2="138 KV" b3="A721" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROZICFRM" b2="138 KV" b3="A722" />
      <ContingencyEquipment Action="L" Type="LN" b1="KRENDALE" b2="138 KV" b3="KRE-ROZI" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROZICFRM" b2="138 KV" b3="ROZ-SENE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SENECAOE" b2="138 KV" b3="CS8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SENECAOE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ZELIENOP" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARKWST2" b2="138 KV" b3="MAR-ZEL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15760</SeqNum>
    <Name>L138.LakeLynn-Pierpont</Name>
    <LastEdit Timestamp="2024-11-13T09:49:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAKELYNN" b2="138 KV" b3="LAK-PIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKELYNN" b2="138 KV" b3="PIERPNT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERPONT" b2="138 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15780</SeqNum>
    <Name>L138.CollinsFerry-Osage</Name>
    <LastEdit Timestamp="2025-01-15T17:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLLINSF" b2="138 KV" b3="COL-OSA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COLLINSF" b2="138 KV" b3="OSAGE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSAGE" b2="138 KV" b3="COLLINSF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15790</SeqNum>
    <Name>138/11.LakeLynn.T1&amp;T2 + LakeLynn.GEN1-4 </Name>
    <LastEdit Timestamp="2025-02-07T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="LAKELYNN" b2="11 KV" b3="GEN  1-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKELYNN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKELYNN" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKELYNN" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKELYNN" b2="138 KV" b3="T2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15800</SeqNum>
    <Name>L230.Limekiln-McCain.232</Name>
    <LastEdit Timestamp="2026-01-08T08:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LIMEKILN" b2="230 KV" b3="LIM-MCN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="230 KV" b3="MCCAIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCAIN" b2="230 KV" b3="B232" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15810</SeqNum>
    <Name>L138.Longreach-PadenCity</Name>
    <LastEdit Timestamp="2025-08-25T12:38:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGREAC" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONGREAC" b2="138 KV" b3="LON-PAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADENCIT" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PADENCIT" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15820</SeqNum>
    <Name>L138.Weirton-MahansLane</Name>
    <LastEdit Timestamp="2025-03-14T09:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAHANSLA" b2="138 KV" b3="252 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAHANSLA" b2="138 KV" b3="MAH-WEI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEIRTON" b2="138 KV" b3="252 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15830</SeqNum>
    <Name>L138.PruntyTown-MapleLake-QuietDell.18</Name>
    <LastEdit Timestamp="2025-01-13T14:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAPLELAK" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAPLELAK" b2="138 KV" b3="MAP-PRU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="P19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="P20" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAPLELAK" b2="138 KV" b3="MAP-QUI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUIETDEL" b2="138 KV" b3="MAPLELAK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15860</SeqNum>
    <Name>L138.Pricehill-Pruntytown</Name>
    <LastEdit Timestamp="2025-08-25T10:47:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PRICEHIL" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRICEHIL" b2="138 KV" b3="CS451J" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRICEHIL" b2="138 KV" b3="PRI-PRUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRICEHIL" b2="138 KV" b3="T3_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="P10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15880</SeqNum>
    <Name>500/138.MeadowBrook.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-25T11:37:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MEADOWBR" b2="500 KV" b3="1XFMR HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="B27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="B28" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MEADOWBR" b2="500 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="500 KV" b3="MDL11" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEADOWBR" b2="500 KV" b3="TRAN  1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15890</SeqNum>
    <Name>500/138.MeadowBrook.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-25T11:38:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MEADOWBR" b2="500 KV" b3="2XFMR HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD13" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEADOWBR" b2="500 KV" b3="TRAN  2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15900</SeqNum>
    <Name>500/138.MeadowBrook.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-09-26T14:46:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MEADOWBR" b2="500 KV" b3="4XFMR HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD17" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEADOWBR" b2="500 KV" b3="TRAN  4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15910</SeqNum>
    <Name>500/138.MeadowBrook.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-12T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MEADOWBR" b2="500 KV" b3="3XFMR HS" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MEADOWBR" b2="500 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="500 KV" b3="MDL11" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEADOWBR" b2="500 KV" b3="TRAN  3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15940</SeqNum>
    <Name>L138.Edinburg-Strasburg</Name>
    <LastEdit Timestamp="2025-09-02T09:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDINBUR4" b2="138 KV" b3="H312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDINBUR4" b2="138 KV" b3="H412" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRASBUR" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRASBUR" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRASBUR" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDINBUR4" b2="138 KV" b3="EDI-STR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STRASBUR" b2="138 KV" b3="SVEC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STRASBUR" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15960</SeqNum>
    <Name>L138.MessickRoad-CacaponTap-Morgan</Name>
    <LastEdit Timestamp="2025-09-09T13:49:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CACAPONT" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CACAPONT" b2="138 KV" b3="CAC-MORG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CACAPONT" b2="138 KV" b3="CACAPNLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MESSICRD" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CACAPONT" b2="138 KV" b3="CAC-MESS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MESSICRD" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGAN" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MORGAN" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15970</SeqNum>
    <Name>L138.MessickRoad-Ridgeley</Name>
    <LastEdit Timestamp="2026-05-08T10:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MESSICRD" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="MESSICRD" b2="138 KV" b3="MES-RID" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MESSICRD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGELEY" b2="138 KV" b3="MESSICRD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>15990</SeqNum>
    <Name>L230.Milesburg-DaleSummit</Name>
    <LastEdit Timestamp="2024-11-27T10:50:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DALESUMM" b2="230 KV" b3="CSMB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DALESUMM" b2="230 KV" b3="DAL-MIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILESBUR" b2="230 KV" b3="DALESUMM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16000</SeqNum>
    <Name>L138.Millville-SleepyHollow</Name>
    <LastEdit Timestamp="2024-11-21T14:21:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLVILL" b2="138 KV" b3="SLEEPYHO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLEEPYHO" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLVILL" b2="138 KV" b3="MIL-SLE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLEEPYHO" b2="34.5 KV" b3="T1LCB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SLEEPYHO" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SLEEPYHO" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16050</SeqNum>
    <Name>L138.Pickens-Monterville-Linwood</Name>
    <LastEdit Timestamp="2026-03-30T18:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LINWOOD" b2="138 KV" b3="LIN-MON" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINWOOD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINWOOD" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONTERVI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PICKENS" b2="138 KV" b3="B174" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONTERVI" b2="138 KV" b3="MON-PIC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16060</SeqNum>
    <Name>L230.MtAiry-NewMarket.210</Name>
    <LastEdit Timestamp="2025-03-14T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MTAIRY" b2="230 KV" b3="NEWMARKE" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTAIRY" b2="230 KV" b3="MTA-NEW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NEWMARKE" b2="230 KV" b3="MTAIRY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16090</SeqNum>
    <Name>L138.NorthPetersburg-NFranklin-SenecaCaverns.178</Name>
    <LastEdit Timestamp="2026-02-10T12:01:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NFRANKLI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NFRANKLI" b2="138 KV" b3="NFR-NPE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPETERSB" b2="138 KV" b3="SENCAV_1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NFRANKLI" b2="138 KV" b3="NFR-SEN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SENECACA" b2="138 KV" b3="NORTHFRA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16100</SeqNum>
    <Name>L138.Page-NorthShenandoah</Name>
    <LastEdit Timestamp="2024-11-07T11:12:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NSHE APS" b2="138 KV" b3="PAGE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAGE" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="L" Type="LN" b1="NSHE APS" b2="138 KV" b3="NSH-PAG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16110</SeqNum>
    <Name>L115.EndlessCaverns-Merck5-NorthShenandoah.118</Name>
    <LastEdit Timestamp="2025-06-10T12:32:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="115 KV" b3="11852" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="115 KV" b3="118T128" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCK5" b2="115 KV" b3="11802" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCK5" b2="115 KV" b3="H202" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MERCK5" b2="115 KV" b3="SC5" />
      <ContingencyEquipment Action="X" Type="XF" b1="MERCK5" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MERCK5" b2="13 KV" b3="TX2LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="MERCK5" b2="115 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MERCK5" b2="35 KV" b3="TX4" />
      <ContingencyEquipment Action="L" Type="LN" b1="NSHENVPC" b2="115 KV" b3="NSH-NSHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSHE APS" b2="138 KV" b3="T3 HSCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="NSHE APS" b2="138 KV" b3="T3 XF" />
      <ContingencyEquipment Action="L" Type="LN" b1="NSHENVPC" b2="115 KV" b3="118A" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENDCAVRN" b2="115 KV" b3="118B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16120</SeqNum>
    <Name>L138.RiverView-NorthVienna-WilliamsCreek.636</Name>
    <LastEdit Timestamp="2025-01-16T15:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="NVIENNA" b2="138 KV" b3="NVI-WIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NVIENNA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIE" b2="138 KV" b3="636" />
      <ContingencyEquipment Action="L" Type="LN" b1="NVIENNA" b2="138 KV" b3="NVI-RIV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLMCRK" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILLMCRK" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16130</SeqNum>
    <Name>OakGrove.Gen1CT</Name>
    <LastEdit Timestamp="2025-01-16T15:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKG APS" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKG APS" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OAKG APS" b2="18 KV" b3="GEN 1" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKG APS" b2="138 KV" b3="GSU 1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKG APS" b2="138 KV" b3="SS1 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16140</SeqNum>
    <Name>OakGrove.Gen2CT</Name>
    <LastEdit Timestamp="2025-01-16T15:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKG APS" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKG APS" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OAKG APS" b2="18 KV" b3="GEN 2" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKG APS" b2="138 KV" b3="GSU 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKG APS" b2="138 KV" b3="SS2 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16150</SeqNum>
    <Name>L138.OakMound-QuietDell.26</Name>
    <LastEdit Timestamp="2025-03-14T11:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKMOUND" b2="138 KV" b3="QUIETDEL" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKMOUND" b2="138 KV" b3="OAK-QUI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="QUIETDEL" b2="138 KV" b3="OAKMOUND" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16170</SeqNum>
    <Name>L138.Osage-Westover-Rivesville.10</Name>
    <LastEdit Timestamp="2025-02-25T19:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="OSAGE" b2="138 KV" b3="OSA-WOV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSAGE" b2="138 KV" b3="WESTOVER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVESVIL" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIVESVIL" b2="138 KV" b3="RIV-WOV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOVE APS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16180</SeqNum>
    <Name>L138.Page-SPerryville</Name>
    <LastEdit Timestamp="2025-01-16T15:54:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PAGE" b2="138 KV" b3="SPERRYVI" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAGE" b2="138 KV" b3="PAG-SPE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPERRYVI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPERRYVI" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16190</SeqNum>
    <Name>L138.PaperCity-Ridgeway</Name>
    <LastEdit Timestamp="2025-03-14T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PAPERCIT" b2="138 KV" b3="PAP-RID" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PAPERCIT" b2="138 KV" b3="RIDGWAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDG APS" b2="138 KV" b3="PAPERCIT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16200</SeqNum>
    <Name>L138.William-Parsons-LoughsLane.156</Name>
    <LastEdit Timestamp="2024-08-20T09:45:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUGHSLA" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOUGHSLA" b2="138 KV" b3="LOU-PAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PARSONS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLIAM" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="L" Type="LN" b1="PARSONS" b2="138 KV" b3="PAR-WIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16210</SeqNum>
    <Name>L138.PineyFork-USSClairton.Z-16</Name>
    <LastEdit Timestamp="2026-03-05T16:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PINEY FK" b2="138 KV" b3="PIN-USS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PINEY FK" b2="138 KV" b3="USSCLR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="USSCLAIR" b2="138 KV" b3="Z-16CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16220</SeqNum>
    <Name>L138.PineyFork-WoodvilleDUQ.Z-106</Name>
    <LastEdit Timestamp="2025-10-15T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PINEY FK" b2="138 KV" b3="PIN-WOO" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PINEY FK" b2="138 KV" b3="WOODVILL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVILL" b2="138 KV" b3="PINEYFOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16230</SeqNum>
    <Name>L500.Belmont-Pleasants.L1 + Pleasants.U1</Name>
    <LastEdit Timestamp="2025-04-23T11:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="500 KV" b3="BEL-PLE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="500 KV" b3="BL5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="500 KV" b3="BL6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PLEA APS" b2="26 KV" b3="GEN  1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLEA APS" b2="26 KV" b3="SS LOAD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLEA APS" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16240</SeqNum>
    <Name>L500.Belmont-Pleasants.L2 &amp; Pleasants.U2</Name>
    <LastEdit Timestamp="2025-08-13T14:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="500 KV" b3="BEL-PLE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="500 KV" b3="BL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="500 KV" b3="BL3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PLEA APS" b2="26 KV" b3="GEN  2" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLEA APS" b2="500 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16260</SeqNum>
    <Name>500/138.Pruntytown.Tran1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-25T10:51:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="PRUNTYTO" b2="500 KV" b3="A351J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="X" Type="XF" b1="PRUNTYTO" b2="500 KV" b3="TRAN  1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16270</SeqNum>
    <Name>500/138.Pruntytown.Tran2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-25T10:52:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="PRUNTYTO" b2="500 KV" b3="A352J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="X" Type="XF" b1="PRUNTYTO" b2="500 KV" b3="TRAN  2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16290</SeqNum>
    <Name>500/138.Pruntytown.Tran3 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-25T10:56:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="PRUNTYTO" b2="500 KV" b3="A353J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B15" />
      <ContingencyEquipment Action="X" Type="XF" b1="PRUNTYTO" b2="500 KV" b3="TRAN  3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16300</SeqNum>
    <Name>500/138.Pruntytown.Tran4 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-25T10:57:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="PRUNTYTO" b2="500 KV" b3="A354J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="X" Type="XF" b1="PRUNTYTO" b2="500 KV" b3="TRAN  4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16310</SeqNum>
    <Name>L138.Pruntytown-ShinnsRun.40</Name>
    <LastEdit Timestamp="2025-08-25T10:57:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="P1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRUNTYTO" b2="138 KV" b3="PRU-SHI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHINNSRN" b2="138 KV" b3="PRUNTYTO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16320</SeqNum>
    <Name>L138.Reid-Ringgold</Name>
    <LastEdit Timestamp="2024-09-30T14:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REID" b2="138 KV" b3="RINGGOLD" />
      <ContingencyEquipment Action="L" Type="LN" b1="REID" b2="138 KV" b3="REI-RIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RINGGOLD" b2="138 KV" b3="REID" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16330</SeqNum>
    <Name>230/138.Ringgold.T3</Name>
    <LastEdit Timestamp="2025-03-05T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RINGGOLD" b2="230 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RINGGOLD" b2="230 KV" b3="MONOCACY" />
      <ContingencyEquipment Action="L" Type="LN" b1="OLDFARM" b2="230 KV" b3="OLD-RIN" />
      <ContingencyEquipment Action="X" Type="XF" b1="RINGGOLD" b2="230 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RINGGOLD" b2="138 KV" b3="T3 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RINGGOLD" b2="230 KV" b3="T5 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16340</SeqNum>
    <Name>230/138.Ringgold.T4</Name>
    <LastEdit Timestamp="2025-03-05T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RINGGOLD" b2="230 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="FROSTOWN" b2="230 KV" b3="FRO-RIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RINGGOLD" b2="230 KV" b3="FROSTOWN" />
      <ContingencyEquipment Action="X" Type="XF" b1="RINGGOLD" b2="230 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RINGGOLD" b2="138 KV" b3="T4 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RINGGOLD" b2="230 KV" b3="T6 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16370</SeqNum>
    <Name>L138.Saltsburg-SocialHall</Name>
    <LastEdit Timestamp="2026-01-09T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTSBUR" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOCIALHA" b2="138 KV" b3="B35" />
      <ContingencyEquipment Action="L" Type="LN" b1="SALTSBUR" b2="138 KV" b3="SAL-SOC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16380</SeqNum>
    <Name>L138.Saltsburg-Vandergrift(Sect.)</Name>
    <LastEdit Timestamp="2025-07-11T12:56:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SALTSBUR" b2="138 KV" b3="SAL-VAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SALTSBUR" b2="138 KV" b3="VANDERGR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="VANDERGR" b2="138 KV" b3="SALTSBUR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16390</SeqNum>
    <Name>L138.Smith-WylieRidge.214</Name>
    <LastEdit Timestamp="2025-02-18T15:25:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SMIT APS" b2="25 KV" b3="B1TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMIT APS" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SMIT APS" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMIT APS" b2="138 KV" b3="T61 DIS" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMIT APS" b2="138 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMIT APS" b2="138 KV" b3="WYLIERID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="B241" />
      <ContingencyEquipment Action="L" Type="LN" b1="SMIT APS" b2="138 KV" b3="SMI-WYL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="W7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16400</SeqNum>
    <Name>Springdale.ST5</Name>
    <LastEdit Timestamp="2025-03-13T20:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SPRINGDA" b2="138 KV" b3="ST-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="ST5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPRINGDA" b2="18 KV" b3="ST5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRINGDA" b2="18 KV" b3="ST5 AUX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16410</SeqNum>
    <Name>Springdale.CT4</Name>
    <LastEdit Timestamp="2025-03-13T20:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SPRINGDA" b2="138 KV" b3="CT-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="CT4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPRINGDA" b2="18 KV" b3="CT4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRINGDA" b2="18 KV" b3="CT4 AUX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16420</SeqNum>
    <Name>Springdale.CT3</Name>
    <LastEdit Timestamp="2025-03-13T20:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SPRINGDA" b2="138 KV" b3="CT-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="CT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPRINGDA" b2="18 KV" b3="CT3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRINGDA" b2="18 KV" b3="CT3 AUX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16430</SeqNum>
    <Name>Springdale.AES1&amp;2</Name>
    <LastEdit Timestamp="2026-04-01T13:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="SPRINGDA" b2="13 KV" b3="AES 1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPRINGDA" b2="13 KV" b3="AES 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPRINGDA" b2="138 KV" b3="CT1_GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPRINGDA" b2="138 KV" b3="CT2_GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16440</SeqNum>
    <Name>L138.Cheswick-Springdale.Z-58 (N.O.)</Name>
    <LastEdit Timestamp="2025-12-29T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWICK" b2="138 KV" b3="SPRING58" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESWICK" b2="138 KV" b3="CHE-SPR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="CHESWICK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16460</SeqNum>
    <Name>L138.Weirton-WylieRidge.216</Name>
    <LastEdit Timestamp="2026-03-12T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WEIRTON" b2="138 KV" b3="WYLIE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="W4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="W5" />
      <ContingencyEquipment Action="L" Type="LN" b1="WEIRTON" b2="138 KV" b3="WEI-WYL2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16470</SeqNum>
    <Name>L138.Weirton-WylieRidge.210</Name>
    <LastEdit Timestamp="2026-03-12T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WEIRTON" b2="138 KV" b3="WYLIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="W12" />
      <ContingencyEquipment Action="L" Type="LN" b1="WEIRTON" b2="138 KV" b3="WEI-WYL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16480</SeqNum>
    <Name>L138.Windsor-Tiltonsville-WestBellaire</Name>
    <LastEdit Timestamp="2026-03-10T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="TILTONS2" b2="69 KV" b3="G DIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="TILTONS2" b2="138 KV" b3="TIL-WBE1" />
      <ContingencyEquipment Action="X" Type="XF" b1="TILTONS2" b2="138 KV" b3="XFMR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TILTONS2" b2="138 KV" b3="TIL-WIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND APS" b2="138 KV" b3="TILTONSV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16530</SeqNum>
    <Name>L345.Tidd-WylieRidge.242</Name>
    <LastEdit Timestamp="2026-02-10T11:44:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="CC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="CC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="345 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="345 KV" b3="B25" />
      <ContingencyEquipment Action="L" Type="LN" b1="TIDD_AEP" b2="345 KV" b3="TID-WYL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16560</SeqNum>
    <Name>L138.Cheswick-Wycoff-Yucon</Name>
    <LastEdit Timestamp="2024-12-19T12:36:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHESWICK" b2="138 KV" b3="CHE-WYCO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWICK" b2="138 KV" b3="Z-65_3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWICK" b2="138 KV" b3="Z-65_4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WYCOFF" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="WYCOFF" b2="138 KV" b3="WYC-YUK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16570</SeqNum>
    <Name>500/345.WylieRidge.T5+T6</Name>
    <LastEdit Timestamp="2026-02-10T11:45:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="345 KV" b3="B24" />
      <ContingencyEquipment Action="X" Type="XF" b1="WYLIERID" b2="500 KV" b3="TRAN  5" />
      <ContingencyEquipment Action="X" Type="XF" b1="WYLIERID" b2="500 KV" b3="TRAN  6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="345 KV" b3="WK1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="500 KV" b3="WL1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="500 KV" b3="WL4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16580</SeqNum>
    <Name>500/345.WylieRidge.T7+T8</Name>
    <LastEdit Timestamp="2026-02-10T11:46:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="345 KV" b3="B25" />
      <ContingencyEquipment Action="X" Type="XF" b1="WYLIERID" b2="500 KV" b3="TRAN  7" />
      <ContingencyEquipment Action="X" Type="XF" b1="WYLIERID" b2="500 KV" b3="TRAN  8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="345 KV" b3="WK6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="500 KV" b3="WL2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="500 KV" b3="WL5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16600</SeqNum>
    <Name>345/138.WylieRidge.1TX (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-18T15:26:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="WYLIERID" b2="345 KV" b3="1 XFMR" />
      <ContingencyEquipment Action="X" Type="XF" b1="WYLIERID" b2="345 KV" b3="1TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="B36" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="B37" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16610</SeqNum>
    <Name>345/138.WylieRidge.2TX (Sctnlz)</Name>
    <LastEdit Timestamp="2025-06-18T12:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="WYLIERID" b2="345 KV" b3="2 XFMR" />
      <ContingencyEquipment Action="X" Type="XF" b1="WYLIERID" b2="345 KV" b3="2TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="W16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16620</SeqNum>
    <Name>345/138.WylieRidge.3TX</Name>
    <LastEdit Timestamp="2025-02-18T15:26:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WYLIERID" b2="345 KV" b3="3TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="345 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="B44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="W12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="W3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="W6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="345 KV" b3="WK6 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16630</SeqNum>
    <Name>L500.SouthBend-Yukon</Name>
    <LastEdit Timestamp="2025-08-25T10:29:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SBEND" b2="500 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBEND" b2="500 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="SBEND" b2="500 KV" b3="SBE-YUK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="500 KV" b3="B106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="500 KV" b3="B195" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16680</SeqNum>
    <Name>L138.YoungWood-Yukon</Name>
    <LastEdit Timestamp="2025-01-14T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="YOUNGWOO" b2="138 KV" b3="YUKON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="Y1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="Y3" />
      <ContingencyEquipment Action="L" Type="LN" b1="YOUNGWOO" b2="138 KV" b3="YOU-YUK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16750</SeqNum>
    <Name>345/138.Highland.T1 (FE)</Name>
    <LastEdit Timestamp="2025-08-19T10:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HIGHLAOE" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="95" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16760</SeqNum>
    <Name>345/138.Highland.T2 (FE)</Name>
    <LastEdit Timestamp="2025-08-19T10:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="128" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="175" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIGHLAOE" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="46" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16790</SeqNum>
    <Name>L345.Chamberlin-Hanna(OE)</Name>
    <LastEdit Timestamp="2026-01-06T10:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="345 KV" b3="B88" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="345 KV" b3="B89" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B106" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANNAOE" b2="345 KV" b3="CHA-HAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16800</SeqNum>
    <Name>L345.Hoytdale-Mansfield</Name>
    <LastEdit Timestamp="2025-01-28T17:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="345 KV" b3="102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="345 KV" b3="106" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANSFIEL" b2="345 KV" b3="MAN-HOY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="46" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="50" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16810</SeqNum>
    <Name>L138.Hoytdale-Maple</Name>
    <LastEdit Timestamp="2026-03-10T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOYTDAL2" b2="138 KV" b3="HOY-MAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLEOE" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLEOE" b2="138 KV" b3="B6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16820</SeqNum>
    <Name>L345.BeaverValley-Mansfield.316</Name>
    <LastEdit Timestamp="2026-03-10T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="316-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="54" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAV DUQ" b2="345 KV" b3="BEA-MAN4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16830</SeqNum>
    <Name>L345.BeaverValley-Mansfield.310</Name>
    <LastEdit Timestamp="2026-03-10T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="310-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="38" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAV DUQ" b2="345 KV" b3="BEA-MAN5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16860</SeqNum>
    <Name>345/138.Star(FE).T1</Name>
    <LastEdit Timestamp="2026-03-10T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="STAR_FE" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="109" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="B258" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="STAR_FE" b2="345 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16870</SeqNum>
    <Name>L345.Tidd-Collier.301</Name>
    <LastEdit Timestamp="2026-03-12T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="301-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="301-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="CC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="CC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLLIER" b2="345 KV" b3="COL-TID" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16880</SeqNum>
    <Name>345/138.BeaverValley.T1-3</Name>
    <LastEdit Timestamp="2026-03-10T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BEAV DUQ" b2="345 KV" b3="1_3TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="138 KV" b3="1_3TIECB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="1_3TIECB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16890</SeqNum>
    <Name>L345.BeaverValley-Crescent.318</Name>
    <LastEdit Timestamp="2026-03-12T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="318-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="318-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAV DUQ" b2="345 KV" b3="BEA-CRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="BEAV1DUQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="BEAV2DUQ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16900</SeqNum>
    <Name>L500.BathCounty-Valley.548</Name>
    <LastEdit Timestamp="2025-03-18T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="VALLEY4" b2="500 KV" b3="548A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="500 KV" b3="H2T548" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="500 KV" b3="H3T548" />
      <ContingencyEquipment Action="S" Type="SD" b1="VALLEY4" b2="500 KV" b3="548CAPA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEY4" b2="500 KV" b3="548T549" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEY4" b2="500 KV" b3="H1T548" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16910</SeqNum>
    <Name>L115.Eclipse-Piney.1038</Name>
    <LastEdit Timestamp="2026-03-10T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ECLIPSE" b2="115 KV" b3="PINEY115" />
      <ContingencyEquipment Action="L" Type="LN" b1="ECLIPSE" b2="115 KV" b3="ECL-PIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEY" b2="115 KV" b3="ECLIPSEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEY" b2="115 KV" b3="ECLIPSSF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16920</SeqNum>
    <Name>L115.Seward-Armagh-Florence-BlairsvilleEast</Name>
    <LastEdit Timestamp="2025-09-15T10:16:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARMAGHTP" b2="115 KV" b3="ARM-FLOR" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARMAGHTP" b2="115 KV" b3="ARM-SEWA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ARMAGHTP" b2="115 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAIRSVE" b2="115 KV" b3="B41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAIRSVE" b2="115 KV" b3="B48" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLAIRSVE" b2="115 KV" b3="BLA-FLO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLORENCE" b2="115 KV" b3="T2 LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="115 KV" b3="B122" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16940</SeqNum>
    <Name>L115.JohnsTown-HillTop</Name>
    <LastEdit Timestamp="2025-01-06T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTOP" b2="115 KV" b3="B50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTOP" b2="115 KV" b3="B56" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLTOP" b2="115 KV" b3="HIL-JOHN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSTOW" b2="115 KV" b3="B49" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16970</SeqNum>
    <Name>L115.Claysburg-Krayn</Name>
    <LastEdit Timestamp="2026-03-10T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSBUR" b2="115 KV" b3="B44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSBUR" b2="115 KV" b3="B45" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYSBUR" b2="115 KV" b3="CLA-KRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KRAYN" b2="115 KV" b3="1123CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KRAYN" b2="115 KV" b3="1123CB3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>16990</SeqNum>
    <Name>L115.Cooper-Seward</Name>
    <LastEdit Timestamp="2025-05-20T11:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOPER" b2="115 KV" b3="B15" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOPER" b2="115 KV" b3="COO-SEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="115 KV" b3="B160" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17000</SeqNum>
    <Name>L115.Cooper-Rosedale-Hilltop-Prospect.1070</Name>
    <LastEdit Timestamp="2025-05-20T11:06:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOPER" b2="115 KV" b3="B7" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOPER" b2="115 KV" b3="COO-ROS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTOP" b2="115 KV" b3="B53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTOP" b2="115 KV" b3="B59" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLTOP" b2="115 KV" b3="HIL-ROS" />
      <ContingencyEquipment Action="L" Type="LN" b1="PROSPECT" b2="115 KV" b3="PRO-ROS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PROSPECT" b2="115 KV" b3="ROSEDLJ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17010</SeqNum>
    <Name>L115.Garrett-GarrettTap-DeepCreek-PennMar.1059</Name>
    <LastEdit Timestamp="2024-06-10T16:18:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEEPCRK" b2="115 KV" b3="1GEN115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEEPCRK" b2="115 KV" b3="2GEN115" />
      <ContingencyEquipment Action="X" Type="XF" b1="DEEPCRK" b2="115 KV" b3="BK 1 11" />
      <ContingencyEquipment Action="X" Type="XF" b1="DEEPCRK" b2="115 KV" b3="BK 2 11" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEEPCRK" b2="115 KV" b3="DEE-GAR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DEEPCRK" b2="12 KV" b3="NO 1 G" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DEEPCRK" b2="12 KV" b3="NO 2 G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DEEPCRK" b2="12 KV" b3="ONE" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARRETAP" b2="115 KV" b3="GAR-GAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARRETAP" b2="115 KV" b3="GAR-PEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARRETT" b2="138 KV" b3="T2 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GARRETT" b2="138 KV" b3="TRAN  2" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENNMAR" b2="115 KV" b3="NO1 TX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENNMAR" b2="22 KV" b3="ONE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENNMAR" b2="115 KV" b3="ROCKWOSF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PENNMAR" b2="22 KV" b3="YOUGHUN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17030</SeqNum>
    <Name>L115.NorthMeshoppen-Mehoopany.1</Name>
    <LastEdit Timestamp="2024-12-18T16:17:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MEHOOPAN" b2="115 KV" b3="3TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEHOOPAN" b2="13 KV" b3="3TX CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEHOOPAN" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEHOOPAN" b2="115 KV" b3="B11" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEHOOPAN" b2="115 KV" b3="MEH-NME1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="115 KV" b3="B107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="115 KV" b3="B108" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17040</SeqNum>
    <Name>L115.NorthMeshoppen-Mehoopany.2</Name>
    <LastEdit Timestamp="2024-12-18T16:17:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MEHOOPAN" b2="115 KV" b3="1TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEHOOPAN" b2="13 KV" b3="1TX CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEHOOPAN" b2="115 KV" b3="2TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEHOOPAN" b2="13 KV" b3="2TX CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEHOOPAN" b2="115 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEHOOPAN" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEHOOPAN" b2="115 KV" b3="MEH-NME2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="115 KV" b3="B104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="115 KV" b3="B105" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17050</SeqNum>
    <Name>L115.EastPike-Glory.1024</Name>
    <LastEdit Timestamp="2025-08-06T13:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EPIKE" b2="115 KV" b3="1 BK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EPIKE" b2="115 KV" b3="BSSEC115" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPIKE" b2="115 KV" b3="EPI-GLO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EPIKE" b2="22 KV" b3="N01TX23C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLORY" b2="115 KV" b3="B45" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLORY" b2="115 KV" b3="B7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17060</SeqNum>
    <Name>L115.EastPike-Lucerne.1008</Name>
    <LastEdit Timestamp="2025-05-12T13:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EPIKE" b2="115 KV" b3="2 BK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EPIKE" b2="115 KV" b3="BSSEC115" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPIKE" b2="115 KV" b3="EPI-LUC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EPIKE" b2="22 KV" b3="N02TX23C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUCERNE" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LUCERNE" b2="115 KV" b3="NO2 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17090</SeqNum>
    <Name>L115.Edinboro-ErieSouth.1017</Name>
    <LastEdit Timestamp="2026-01-20T17:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EDINBORO" b2="115 KV" b3="1TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDINBORO" b2="115 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDINBORO" b2="34.5 KV" b3="B1TX" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDINBORO" b2="115 KV" b3="EDI-ERI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="115 KV" b3="B157" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17110</SeqNum>
    <Name>L115.ErieSouth-UnionCity</Name>
    <LastEdit Timestamp="2024-11-20T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="115 KV" b3="B64" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERIES" b2="115 KV" b3="ERI-UNI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIONCIT" b2="115 KV" b3="B23" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17120</SeqNum>
    <Name>L115.ErieWest-Springboro</Name>
    <LastEdit Timestamp="2025-12-23T07:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="115 KV" b3="B142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="115 KV" b3="B145" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERIEW" b2="115 KV" b3="ERI-SPR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGBO" b2="115 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17130</SeqNum>
    <Name>L115.ErieWest-FairviewEast</Name>
    <LastEdit Timestamp="2025-12-29T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="115 KV" b3="B136" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="115 KV" b3="B139" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERIEW" b2="115 KV" b3="ERI-FAI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRVIEW" b2="115 KV" b3="B19CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17140</SeqNum>
    <Name>L115.Geneva-FranklinTap-Wayne</Name>
    <LastEdit Timestamp="2024-12-10T13:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKTAP" b2="115 KV" b3="FRN-GEN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKTAP" b2="115 KV" b3="FRN-WAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GENEVA" b2="115 KV" b3="WAYNE CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE" b2="115 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE" b2="115 KV" b3="B6 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17150</SeqNum>
    <Name>L115.Geneva-Vitrogls-APCI-FranklinTap-MorganSt</Name>
    <LastEdit Timestamp="2025-04-24T10:56:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="APCI" b2="115 KV" b3="APC-GEN" />
      <ContingencyEquipment Action="L" Type="LN" b1="APCI" b2="115 KV" b3="APC-VITR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="APCI" b2="115 KV" b3="API" />
      <ContingencyEquipment Action="OP" Type="CB" b1="APCI" b2="115 KV" b3="API CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="APCI" b2="115 KV" b3="API2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKTAP" b2="115 KV" b3="FRA-VITR" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKTAP" b2="115 KV" b3="FRN-MOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GENEVA" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANST" b2="115 KV" b3="GENEVASF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VITROGLS" b2="115 KV" b3="VITROGLS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17160</SeqNum>
    <Name>L115.Glory-Seward</Name>
    <LastEdit Timestamp="2025-08-06T13:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLORY" b2="115 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLORY" b2="115 KV" b3="B51" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLORY" b2="115 KV" b3="GLO-SEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="115 KV" b3="B137" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17170</SeqNum>
    <Name>L115.Grandview-Titusville</Name>
    <LastEdit Timestamp="2026-03-27T09:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GRANDVIE" b2="115 KV" b3="GRA-TIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDVIE" b2="115 KV" b3="TITUSVIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TITUSVIL" b2="34.5 KV" b3="B2TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TITUSVIL" b2="115 KV" b3="B7" />
      <ContingencyEquipment Action="X" Type="XF" b1="TITUSVIL" b2="115 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17190</SeqNum>
    <Name>L115.Hooversville-Somerset.1031</Name>
    <LastEdit Timestamp="2026-03-12T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HOOVERSV" b2="115 KV" b3="HOO-SOM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOOVERSV" b2="115 KV" b3="SOMERSSF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOME PN" b2="115 KV" b3="HOOVRSSF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17200</SeqNum>
    <Name>L115.Hooversville-Tower51</Name>
    <LastEdit Timestamp="2025-01-27T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOOVERSV" b2="115 KV" b3="B29" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOOVERSV" b2="115 KV" b3="HOO-TOW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWER51" b2="115 KV" b3="HOOVRSSF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17230</SeqNum>
    <Name>L115.JacksonRd-Seward.1080</Name>
    <LastEdit Timestamp="2024-11-21T14:37:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PN" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PN" b2="115 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACK PN" b2="115 KV" b3="JAC-SEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="115 KV" b3="B136" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17240</SeqNum>
    <Name>L115.Johnstown-Prospect</Name>
    <LastEdit Timestamp="2025-04-15T13:45:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSTOW" b2="115 KV" b3="B52" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSTOW" b2="115 KV" b3="JOH-PRO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PROSPECT" b2="115 KV" b3="B25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17250</SeqNum>
    <Name>L115.PennMar-Highpoint</Name>
    <LastEdit Timestamp="2026-03-12T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHPNT" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHPNT" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHPNT" b2="115 KV" b3="HIG-PEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENNMAR" b2="115 KV" b3="ROCKWOSF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17260</SeqNum>
    <Name>L115.Piney-Timblin.1091</Name>
    <LastEdit Timestamp="2026-03-12T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PINEY" b2="115 KV" b3="PIN-TIM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEY" b2="115 KV" b3="TIMBLINA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEY" b2="115 KV" b3="TIMBLISF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMBLIN" b2="115 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17270</SeqNum>
    <Name>L115.Rockwood-Somerset</Name>
    <LastEdit Timestamp="2025-01-09T14:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKWOOD" b2="115 KV" b3="BSSEC115" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKWOOD" b2="115 KV" b3="NO1 TX" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKWOOD" b2="115 KV" b3="ROC-SOM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOME PN" b2="115 KV" b3="B22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17280</SeqNum>
    <Name>L115.Seward-Tower51.1097</Name>
    <LastEdit Timestamp="2025-07-25T16:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="115 KV" b3="B110" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEWARD" b2="115 KV" b3="SEW-TOW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWER51" b2="115 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17290</SeqNum>
    <Name>L115.Titusville-UnionCity</Name>
    <LastEdit Timestamp="2026-04-14T09:28:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TITUSVIL" b2="34.5 KV" b3="B1TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TITUSVIL" b2="115 KV" b3="B7" />
      <ContingencyEquipment Action="X" Type="XF" b1="TITUSVIL" b2="115 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TITUSVIL" b2="115 KV" b3="TIT-UNI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="UNIONCIT" b2="115 KV" b3="A25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIONCIT" b2="115 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17300</SeqNum>
    <Name>L115.Belfast-AMDEaston-Northwood</Name>
    <LastEdit Timestamp="2025-04-25T09:19:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMDEASTN" b2="115 KV" b3="AMD-BELF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMDEASTN" b2="115 KV" b3="CUSTLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELFAST" b2="115 KV" b3="95162" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELFAST" b2="115 KV" b3="T 951" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMDEASTN" b2="115 KV" b3="AMD-NORW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="115 KV" b3="B171" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="115 KV" b3="B172" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17310</SeqNum>
    <Name>L115.Belfast-NBangor.951</Name>
    <LastEdit Timestamp="2026-03-12T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELFAST" b2="115 KV" b3="95262" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELFAST" b2="115 KV" b3="BEL-NBA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELFAST" b2="115 KV" b3="T 951" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBANGOR" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBANGOR" b2="115 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17330</SeqNum>
    <Name>L115.CatTractor-Pleasureville.971</Name>
    <LastEdit Timestamp="2025-05-07T10:20:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CATTRACT" b2="115 KV" b3="97112" />
      <ContingencyEquipment Action="L" Type="LN" b1="CATTRACT" b2="115 KV" b3="CAT-PLV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLVL ME" b2="115 KV" b3="97172" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17350</SeqNum>
    <Name>L115.Glendon-Hosensack.914</Name>
    <LastEdit Timestamp="2026-03-12T09:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDON" b2="115 KV" b3="91432" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSME" b2="115 KV" b3="B4B52" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENDON" b2="115 KV" b3="GLE-HOS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17360</SeqNum>
    <Name>L115.Hamilton-Jackson.965</Name>
    <LastEdit Timestamp="2025-03-26T10:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMILTON" b2="115 KV" b3="96512" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAMILTON" b2="115 KV" b3="HAM-JAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="115 KV" b3="B22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17370</SeqNum>
    <Name>L115.Hamilton-Hunterstown.961</Name>
    <LastEdit Timestamp="2025-03-26T10:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMILTON" b2="115 KV" b3="96112" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAMILTON" b2="115 KV" b3="HAM-HUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="115 KV" b3="96192" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17380</SeqNum>
    <Name>L115.YorkInc-HarleyDavidson-Pleasureville.986</Name>
    <LastEdit Timestamp="2026-03-12T09:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARLEY D" b2="115 KV" b3="1 BANK" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARLEY D" b2="115 KV" b3="2 BANK" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARLEY D" b2="115 KV" b3="HAR-PLV" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARLEY D" b2="115 KV" b3="HAR-YOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLVL ME" b2="115 KV" b3="98672" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORK INC" b2="115 KV" b3="98652" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17410</SeqNum>
    <Name>Hunterstown.CT1-3</Name>
    <LastEdit Timestamp="2026-03-12T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HUNTERST" b2="115 KV" b3="3 TX 11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="115 KV" b3="B392" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="13 KV" b3="G195" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="13 KV" b3="G295" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="13 KV" b3="G395" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="13 KV" b3="HUNTR1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="13 KV" b3="HUNTR2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="13 KV" b3="HUNTR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17430</SeqNum>
    <Name>L115.Jackson-NorthHanover.968</Name>
    <LastEdit Timestamp="2026-03-12T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="115 KV" b3="B23" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACK ME" b2="115 KV" b3="JAC-NHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHANOVER" b2="115 KV" b3="96832" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHANOVER" b2="115 KV" b3="96838" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17450</SeqNum>
    <Name>L115.NorthBangor-Portland.953</Name>
    <LastEdit Timestamp="2024-10-08T13:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NBANGOR" b2="115 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBANGOR" b2="115 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="NBANGOR" b2="115 KV" b3="NBA-POR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTLAND" b2="115 KV" b3="B95312" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17460</SeqNum>
    <Name>L115.WestGate-SmithJct-YorkInc.967</Name>
    <LastEdit Timestamp="2025-03-31T16:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SMITHJCT" b2="115 KV" b3="SMI-SMI" />
      <ContingencyEquipment Action="L" Type="LN" b1="SMITHJCT" b2="115 KV" b3="SMI-WES" />
      <ContingencyEquipment Action="L" Type="LN" b1="SMITHJCT" b2="115 KV" b3="SMI-YOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHST" b2="115 KV" b3="96702" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHST" b2="115 KV" b3="96708" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTGATE" b2="115 KV" b3="B96712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORK INC" b2="115 KV" b3="96752" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17480</SeqNum>
    <Name>L115.Tolna-JohnsonControls-Hill</Name>
    <LastEdit Timestamp="2024-12-18T16:27:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILL" b2="115 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILL" b2="115 KV" b3="B18" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILL" b2="115 KV" b3="HIL-JOH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JOHNSONC" b2="115 KV" b3="JOHNSON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOLNA" b2="115 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSONC" b2="115 KV" b3="JOH-TOL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17490</SeqNum>
    <Name>L115.Yorkana-Yoe-Windsor.989</Name>
    <LastEdit Timestamp="2024-11-21T14:28:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND ME" b2="115 KV" b3="B98932" />
      <ContingencyEquipment Action="L" Type="LN" b1="WIND ME" b2="115 KV" b3="WIN-YOE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YOE" b2="115 KV" b3="T989" />
      <ContingencyEquipment Action="L" Type="LN" b1="YOE" b2="115 KV" b3="YOE-YOR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="115 KV" b3="98982" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17500</SeqNum>
    <Name>L115.Gilbert-Glendon.A-911</Name>
    <LastEdit Timestamp="2025-05-22T13:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBERT" b2="115 KV" b3="A911 OC" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GILBERT" b2="115 KV" b3="A911CBSD" />
      <ContingencyEquipment Action="L" Type="LN" b1="GILBERT" b2="115 KV" b3="GIL-GLEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDON" b2="115 KV" b3="91132" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17510</SeqNum>
    <Name>L115.WWharton-StoneyBrook-Whippany.G943</Name>
    <LastEdit Timestamp="2025-02-18T15:21:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STON JC" b2="115 KV" b3="BK 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="STON JC" b2="115 KV" b3="STO-WHI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STON JC" b2="115 KV" b3="STO-WWH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHIPPANY" b2="115 KV" b3="B78" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="115 KV" b3="B62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="115 KV" b3="B63" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17520</SeqNum>
    <Name>L115.GoreJct-RollingMeadows</Name>
    <LastEdit Timestamp="2025-05-13T12:54:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOREJCT" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOREJCT" b2="115 KV" b3="ERIES CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOREJCT" b2="115 KV" b3="GOR-ROL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROLL PN" b2="115 KV" b3="1 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17530</SeqNum>
    <Name>L115.GoreJct-GESGTap-GreenGarden-ErieSouth</Name>
    <LastEdit Timestamp="2025-06-19T12:04:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ERIES" b2="115 KV" b3="ERI-GES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="115 KV" b3="GOREJCT" />
      <ContingencyEquipment Action="L" Type="LN" b1="GESGTAP" b2="115 KV" b3="GES-GOR" />
      <ContingencyEquipment Action="L" Type="LN" b1="GESGTAP" b2="115 KV" b3="GES-GRN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOREJCT" b2="115 KV" b3="ERIES CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENGAR" b2="115 KV" b3="ERIE115" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17570</SeqNum>
    <Name>L115.MiddleTownJct-YorkHaven-Cly.978</Name>
    <LastEdit Timestamp="2024-12-13T10:54:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLY" b2="115 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLY" b2="115 KV" b3="B7" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLY" b2="115 KV" b3="CLY-YOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="115 KV" b3="B97882" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDDLJCT" b2="115 KV" b3="MID-YOR8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKHAVE" b2="115 KV" b3="97837" />
      <ContingencyEquipment Action="CL" Type="CB" b1="YORKHAVE" b2="115 KV" b3="T-970" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17600</SeqNum>
    <Name>L115.Flanders-WestWharton.R-918</Name>
    <LastEdit Timestamp="2026-01-16T10:07:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FLANDERS" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLANDERS" b2="115 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLANDERS" b2="115 KV" b3="FLA-WWH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="115 KV" b3="R918OCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17610</SeqNum>
    <Name>L115.Englishtown-DeepRun-Sayreville.C3</Name>
    <LastEdit Timestamp="2026-02-10T11:14:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DEEPRN" b2="115 KV" b3="BANK 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEEPRN" b2="115 KV" b3="DEE-ENGC" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEEPRN" b2="115 KV" b3="DEE-SAYC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="115 KV" b3="B128" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="34.5 KV" b3="B153" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="115 KV" b3="B160" />
      <ContingencyEquipment Action="X" Type="XF" b1="ENGLISHT" b2="115 KV" b3="BK 1TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="115 KV" b3="BC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="115 KV" b3="C7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17620</SeqNum>
    <Name>L115.Englishtown-DeepRun-Sayreville.B2</Name>
    <LastEdit Timestamp="2025-12-11T08:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DEEPRN" b2="115 KV" b3="BANK 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEEPRN" b2="115 KV" b3="DEE-ENGB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEEPRN" b2="115 KV" b3="DEE-SAYB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="115 KV" b3="B128" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="115 KV" b3="B6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ENGLISHT" b2="115 KV" b3="BK7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="115 KV" b3="B45" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="115 KV" b3="BC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SAYREVIL" b2="115 KV" b3="BK 4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="115 KV" b3="BK4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17640</SeqNum>
    <Name>L230.Ontelaunee-NorthTemple.1014 + Ontelaunee.CC</Name>
    <LastEdit Timestamp="2026-03-12T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NTEMPLE" b2="230 KV" b3="100112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTEMPLE" b2="230 KV" b3="103112" />
      <ContingencyEquipment Action="L" Type="LN" b1="NTEMPLE" b2="230 KV" b3="NTE-ONT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONTELAUN" b2="230 KV" b3="101452" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONTELAUN" b2="230 KV" b3="101482" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ONTELAUN" b2="18 KV" b3="CT1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ONTELAUN" b2="230 KV" b3="CT1 XFMR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ONTELAUN" b2="18 KV" b3="CT2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ONTELAUN" b2="230 KV" b3="CT2 XFMR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ONTELAUN" b2="18 KV" b3="STM" />
      <ContingencyEquipment Action="X" Type="XF" b1="ONTELAUN" b2="230 KV" b3="STM XFMR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17710</SeqNum>
    <Name>138/115.Germantown.T1</Name>
    <LastEdit Timestamp="2026-03-12T10:39:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="GERMANTO" b2="138 KV" b3="1 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GERMANTO" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GERMANTO" b2="138 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17720</SeqNum>
    <Name>230/115.Northwood.6Bank</Name>
    <LastEdit Timestamp="2025-04-25T09:13:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NORTHWOO" b2="230 KV" b3="6 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="115 KV" b3="B169" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="115 KV" b3="B172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="230 KV" b3="B28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="230 KV" b3="B30" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17730</SeqNum>
    <Name>230/115.Portland.3TR</Name>
    <LastEdit Timestamp="2025-04-28T23:28:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PORTLAND" b2="230 KV" b3="3 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTLAND" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTLAND" b2="230 KV" b3="B312" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17740</SeqNum>
    <Name>L115.PequestRiver-Belvedere-MorrisPk-Gilbert.S-919</Name>
    <LastEdit Timestamp="2025-09-02T09:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELVEDER" b2="115 KV" b3="BEL-MER" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELVEDER" b2="115 KV" b3="BEL-PEQ" />
      <ContingencyEquipment Action="L" Type="LN" b1="GILBERT" b2="115 KV" b3="GIL-MRP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBERT" b2="115 KV" b3="S919 OC" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GILBERT" b2="115 KV" b3="S919CBSD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MERRILCR" b2="115 KV" b3="1 TX 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERRILCR" b2="115 KV" b3="MER-MRP" />
      <ContingencyEquipment Action="X" Type="XF" b1="MORRISPA" b2="115 KV" b3="BK1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MORRISPA" b2="35 KV" b3="DUMBK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEQUESTR" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEQUESTR" b2="115 KV" b3="B7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17760</SeqNum>
    <Name>230/115.Sayreville.T13</Name>
    <LastEdit Timestamp="2025-05-28T13:06:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="B199" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="115 KV" b3="B42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="115 KV" b3="B43" />
      <ContingencyEquipment Action="X" Type="XF" b1="SAYREVIL" b2="230 KV" b3="BK 13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17770</SeqNum>
    <Name>230/115.Englishtown.BK4</Name>
    <LastEdit Timestamp="2025-05-16T12:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="115 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="230 KV" b3="B81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="230 KV" b3="B87" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="115 KV" b3="B9" />
      <ContingencyEquipment Action="X" Type="XF" b1="ENGLISHT" b2="230 KV" b3="BK 4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17780</SeqNum>
    <Name>230/115.ErieSouth.T1</Name>
    <LastEdit Timestamp="2024-10-24T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="230 KV" b3="B140" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="115 KV" b3="B163" />
      <ContingencyEquipment Action="X" Type="XF" b1="ERIES" b2="230 KV" b3="NO.1 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17800</SeqNum>
    <Name>345/115.Wayne.2TX</Name>
    <LastEdit Timestamp="2024-10-17T15:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE" b2="345 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE" b2="345 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE" b2="115 KV" b3="B9" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAYNE" b2="345 KV" b3="NO2 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17880</SeqNum>
    <Name>L500.BathCounty-Lexington.547</Name>
    <LastEdit Timestamp="2025-03-18T16:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LEXINGTN" b2="500 KV" b3="547A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="500 KV" b3="H1T547" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="500 KV" b3="H2T547" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="500 KV" b3="54702" />
      <ContingencyEquipment Action="S" Type="SD" b1="LEXINGTN" b2="500 KV" b3="547CAPA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="500 KV" b3="547T566" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17910</SeqNum>
    <Name>L230.Benning-Ritchie.23001</Name>
    <LastEdit Timestamp="2026-03-12T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="4BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="4CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENNING" b2="230 KV" b3="BEN-RIT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="230 KV" b3="23001B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17920</SeqNum>
    <Name>L230.OakGrove-Ritchie.23061 + 230/69.Ritchie.T4</Name>
    <LastEdit Timestamp="2026-03-12T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="5AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="5CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKGROVE" b2="230 KV" b3="OAK-RIT1" />
      <ContingencyEquipment Action="X" Type="XF" b1="RITCHIE" b2="230 KV" b3="123-T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="230 KV" b3="23001B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="69 KV" b3="4TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="69 KV" b3="4TS4B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17930</SeqNum>
    <Name>L69.FTSlocum-12th&amp;Irving.69168</Name>
    <LastEdit Timestamp="2026-03-24T08:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="12THST" b2="69 KV" b3="12T-FTS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12THST" b2="69 KV" b3="1BB" />
      <ContingencyEquipment Action="X" Type="XF" b1="12THST" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="12THST" b2="13.8 KV" b3="T1_LOAD" />
      <ContingencyEquipment Action="P" Type="XF" b1="FTSLOCUM" b2="69 KV" b3="190-6R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FTSLOCUM" b2="69 KV" b3="4BB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FTSLOCUM" b2="69 KV" b3="T4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FTSLOCUM" b2="13.8 KV" b3="T4_LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17940</SeqNum>
    <Name>L69.FTSlocum-Takoma-Sligo.69054/69130</Name>
    <LastEdit Timestamp="2026-03-24T11:16:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FTSLOCUM" b2="69 KV" b3="3BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="FTSLOCUM" b2="69 KV" b3="FTS-TAK4" />
      <ContingencyEquipment Action="X" Type="XF" b1="FTSLOCUM" b2="69 KV" b3="T3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FTSLOCUM" b2="13.8 KV" b3="T3_LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="SLIGOPEP" b2="69 KV" b3="3T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLIGOPEP" b2="13 KV" b3="3TSB" />
      <ContingencyEquipment Action="L" Type="LN" b1="SLIGOPEP" b2="69 KV" b3="SLI-TAK4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K4B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17950</SeqNum>
    <Name>L69.FTSlocum-Takoma.69167</Name>
    <LastEdit Timestamp="2026-03-24T11:13:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FTSLOCUM" b2="69 KV" b3="2BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="FTSLOCUM" b2="69 KV" b3="FTS-TAK7" />
      <ContingencyEquipment Action="X" Type="XF" b1="FTSLOCUM" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FTSLOCUM" b2="13.8 KV" b3="T2_LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K3B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17960</SeqNum>
    <Name>L115.Benning-Tuxedo.11502</Name>
    <LastEdit Timestamp="2025-04-10T15:59:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="115 KV" b3="14B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENNING" b2="115 KV" b3="BEN-TUX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUXEDO" b2="115 KV" b3="11502B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17970</SeqNum>
    <Name>L115.Benning-Tuxedo-Bladensburg.11501/11513</Name>
    <LastEdit Timestamp="2025-04-11T17:35:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="115 KV" b3="13B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENNING" b2="115 KV" b3="BEN-TUX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLADENSB" b2="115 KV" b3="1TPL" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLADENSB" b2="115 KV" b3="BLA-TUX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="TUXEDO" b2="115 KV" b3="148-3T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUXEDO" b2="13 KV" b3="3TSB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUXEDO" b2="115 KV" b3="K1-33B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17980</SeqNum>
    <Name>L115.Lanham-Tuxedo.11503 + 115/13.Tuxedo.T1</Name>
    <LastEdit Timestamp="2026-03-13T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="115 KV" b3="11503B" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANHAM" b2="115 KV" b3="LAN-TUX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUXEDO" b2="115 KV" b3="11503L" />
      <ContingencyEquipment Action="X" Type="XF" b1="TUXEDO" b2="115 KV" b3="148-1T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUXEDO" b2="13 KV" b3="1TSB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUXEDO" b2="115 KV" b3="K1-31B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>17990</SeqNum>
    <Name>L115.Tuxedo-Lanham-Wildercroft.11504/11514</Name>
    <LastEdit Timestamp="2026-03-19T08:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LANHAM" b2="115 KV" b3="149-2T" />
      <ContingencyEquipment Action="X" Type="XF" b1="LANHAM" b2="115 KV" b3="149-4T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="34 KV" b3="2TS2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="34 KV" b3="2TS3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="13 KV" b3="4TSB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="115 KV" b3="K2-32B" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANHAM" b2="115 KV" b3="LAN-TUX4" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANHAM" b2="115 KV" b3="LAN-WIL4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUXEDO" b2="115 KV" b3="11504B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILDERCR" b2="115 KV" b3="2TPL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18000</SeqNum>
    <Name>L115.Bowie-Lanham-Wildercroft.11505/11515</Name>
    <LastEdit Timestamp="2026-03-19T08:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="115 KV" b3="115K3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="115 KV" b3="115K4B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOWIE" b2="115 KV" b3="BOW-LAN5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="115 KV" b3="11503B" />
      <ContingencyEquipment Action="X" Type="XF" b1="LANHAM" b2="115 KV" b3="149-1T" />
      <ContingencyEquipment Action="X" Type="XF" b1="LANHAM" b2="115 KV" b3="149-5T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="34 KV" b3="1TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="34 KV" b3="1TS2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="13 KV" b3="5TSB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANHAM" b2="115 KV" b3="LAN-WIL5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILDERCR" b2="115 KV" b3="1TPL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18010</SeqNum>
    <Name>L115.Lanham-Bowie.11506</Name>
    <LastEdit Timestamp="2025-06-19T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="115 KV" b3="115K1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="115 KV" b3="115K5B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOWIE" b2="115 KV" b3="BOW-LAN6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="115 KV" b3="11506B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18030</SeqNum>
    <Name>L138.BuzzardPoint-Southwest.13841</Name>
    <LastEdit Timestamp="2026-03-19T08:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUZZARD" b2="138 KV" b3="13841L" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUZZARD" b2="138 KV" b3="BUZ-SOU1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SOUTHWES" b2="138 KV" b3="13841LB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18040</SeqNum>
    <Name>L138.BuzzardPoint-Southwest.13843</Name>
    <LastEdit Timestamp="2026-03-19T08:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUZZARD" b2="138 KV" b3="13843L" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUZZARD" b2="138 KV" b3="BUZ-SOU3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SOUTHWES" b2="138 KV" b3="13843LB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18050</SeqNum>
    <Name>L138.BuzzardPoint-10thStreet.13842</Name>
    <LastEdit Timestamp="2026-03-19T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="10THST" b2="138 KV" b3="10T-BUZ4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="10THST" b2="138 KV" b3="13842DIS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUZZARD" b2="138 KV" b3="13842L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18060</SeqNum>
    <Name>L138.BuzzardPoint-10thStreet.13862</Name>
    <LastEdit Timestamp="2026-03-19T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="10THST" b2="138 KV" b3="10T-BUZ6" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="10THST" b2="138 KV" b3="13862DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUZZARD" b2="138 KV" b3="13862B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18070</SeqNum>
    <Name>L138.10thStreet-SouthWest.13833 </Name>
    <LastEdit Timestamp="2025-06-16T17:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="10THST" b2="138 KV" b3="10T-SOU" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="10THST" b2="138 KV" b3="13833DIS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SOUTHWES" b2="138 KV" b3="13833LB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18080</SeqNum>
    <Name>L138.10thStreet-OStreet.13832</Name>
    <LastEdit Timestamp="2024-11-20T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="10THST" b2="138 KV" b3="10T-OST" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="10THST" b2="138 KV" b3="13832DIS" />
      <ContingencyEquipment Action="P" Type="XF" b1="OST" b2="138 KV" b3="002-6R" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OST" b2="138 KV" b3="6RLB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18090</SeqNum>
    <Name>L138.Southwest-OStreet.13831</Name>
    <LastEdit Timestamp="2024-11-20T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="P" Type="XF" b1="OST" b2="138 KV" b3="002-5R" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OST" b2="138 KV" b3="5RLB" />
      <ContingencyEquipment Action="L" Type="LN" b1="OST" b2="138 KV" b3="OST-SOU" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SOUTHWES" b2="138 KV" b3="13831LB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18100</SeqNum>
    <Name>L138.OStreet-Vanness.13822</Name>
    <LastEdit Timestamp="2024-11-20T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="OST" b2="138 KV" b3="13822LB" />
      <ContingencyEquipment Action="L" Type="LN" b1="OST" b2="138 KV" b3="OST-VAN2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="VANNESS" b2="138 KV" b3="13822LB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18110</SeqNum>
    <Name>L138.Harrison-Bethesda-BellsMillRd.13816/02</Name>
    <LastEdit Timestamp="2025-02-03T19:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K4" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLSMIL" b2="138 KV" b3="BEL-BET2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BETHESDA" b2="138 KV" b3="006-7T" />
      <ContingencyEquipment Action="P" Type="XF" b1="BETHESDA" b2="34 KV" b3="7T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHESDA" b2="34 KV" b3="7TS3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHESDA" b2="34 KV" b3="7TS4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISN" b2="138 KV" b3="3B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHESDA" b2="138 KV" b3="BET-HAR6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARRISN" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18120</SeqNum>
    <Name>L138.Harrison-Bethesda-BellsMill.13815/01</Name>
    <LastEdit Timestamp="2025-01-31T15:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K9" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLSMIL" b2="138 KV" b3="BEL-BET1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BETHESDA" b2="138 KV" b3="006-5T" />
      <ContingencyEquipment Action="P" Type="XF" b1="BETHESDA" b2="34 KV" b3="5T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHESDA" b2="34 KV" b3="5TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHESDA" b2="34 KV" b3="5TS2B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHESDA" b2="138 KV" b3="BET-HAR5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISN" b2="138 KV" b3="1B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARRISN" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18130</SeqNum>
    <Name>L138.Vanness-Bethesda-BellsMill.13811</Name>
    <LastEdit Timestamp="2026-03-02T12:46:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K5" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLSMIL" b2="138 KV" b3="BEL-BET3" />
      <ContingencyEquipment Action="X" Type="XF" b1="BETHESDA" b2="138 KV" b3="006-6T" />
      <ContingencyEquipment Action="P" Type="XF" b1="BETHESDA" b2="34 KV" b3="6T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHESDA" b2="34 KV" b3="6TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHESDA" b2="34 KV" b3="6TS3B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHESDA" b2="138 KV" b3="BET-VAN1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="VANNESS" b2="138 KV" b3="13811LB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18140</SeqNum>
    <Name>L138.Vanness-Bethesda-BellsMill.13812</Name>
    <LastEdit Timestamp="2025-06-16T17:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLSMIL" b2="138 KV" b3="138K8" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLSMIL" b2="138 KV" b3="BEL-BET4" />
      <ContingencyEquipment Action="X" Type="XF" b1="BETHESDA" b2="138 KV" b3="006-8T" />
      <ContingencyEquipment Action="P" Type="XF" b1="BETHESDA" b2="34 KV" b3="8T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHESDA" b2="34 KV" b3="8TS2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHESDA" b2="34 KV" b3="8TS4B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHESDA" b2="138 KV" b3="BET-VAN2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="VANNESS" b2="138 KV" b3="13812LB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18170</SeqNum>
    <Name>L69.Benning-12th&amp;Irving.69049R</Name>
    <LastEdit Timestamp="2026-01-27T10:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="12THST" b2="69 KV" b3="12T-BEN9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12THST" b2="69 KV" b3="2BB" />
      <ContingencyEquipment Action="X" Type="XF" b1="12THST" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="12THST" b2="13.8 KV" b3="T2_LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K10B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K8B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENNING" b2="69 KV" b3="LOAD49" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18180</SeqNum>
    <Name>L69.Benning-12th&amp;Irving.69048R</Name>
    <LastEdit Timestamp="2026-01-27T10:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="12THST" b2="69 KV" b3="12T-BEN8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12THST" b2="69 KV" b3="4BB" />
      <ContingencyEquipment Action="X" Type="XF" b1="12THST" b2="69 KV" b3="T4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="12THST" b2="13.8 KV" b3="T4_LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K4B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENNING" b2="69 KV" b3="LOAD48" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18230</SeqNum>
    <Name>L138.ECRRF-Foundry.B-1328 + ECRRF.U2</Name>
    <LastEdit Timestamp="2024-10-03T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ECRRF" b2="138 KV" b3="ECR-FOU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ECRRF" b2="13 KV" b3="ECRF#2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ECRRF" b2="138 KV" b3="NO 2GSSF" />
      <ContingencyEquipment Action="X" Type="XF" b1="ECRRF" b2="138 KV" b3="NO 2GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ECRRF" b2="138 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="FOUNDRY" b2="138 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOUNDRY" b2="138 KV" b3="SECT 2-3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FOUNDRY" b2="138 KV" b3="TRAN T-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18300</SeqNum>
    <Name>L230.YardsCreek-Kittatinny.M1027 + YC.U1&amp;2&amp;3</Name>
    <LastEdit Timestamp="2026-01-21T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTATIN" b2="230 KV" b3="B100" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTATIN" b2="230 KV" b3="B97" />
      <ContingencyEquipment Action="X" Type="XF" b1="YARDSCRE" b2="230 KV" b3="BK 1 23" />
      <ContingencyEquipment Action="X" Type="XF" b1="YARDSCRE" b2="230 KV" b3="BK 2 23" />
      <ContingencyEquipment Action="X" Type="XF" b1="YARDSCRE" b2="230 KV" b3="BK 3 23" />
      <ContingencyEquipment Action="L" Type="LN" b1="KITTATIN" b2="230 KV" b3="KIT-YAR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="YARDSCRE" b2="14 KV" b3="UNIT01" />
      <ContingencyEquipment Action="U" Type="GEN" b1="YARDSCRE" b2="14 KV" b3="UNIT02" />
      <ContingencyEquipment Action="U" Type="GEN" b1="YARDSCRE" b2="14 KV" b3="UNIT03" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YARDSCRE" b2="230 KV" b3="UNT 1 AC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YARDSCRE" b2="230 KV" b3="UNT 2 AC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YARDSCRE" b2="230 KV" b3="UNT 3 AC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18330</SeqNum>
    <Name>Hunterstown.CT101</Name>
    <LastEdit Timestamp="2024-10-17T15:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="18 KV" b3="CT101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="18 KV" b3="GEN101CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18340</SeqNum>
    <Name>Hunterstown.CT201</Name>
    <LastEdit Timestamp="2024-10-17T15:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="18 KV" b3="CT201" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="18 KV" b3="GEN201" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18350</SeqNum>
    <Name>Hunterstown.CT301</Name>
    <LastEdit Timestamp="2024-10-17T15:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="18 KV" b3="CT301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="18 KV" b3="GEN301" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18360</SeqNum>
    <Name>Hunterstown.ST401</Name>
    <LastEdit Timestamp="2024-10-18T13:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="22 KV" b3="GEN401CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="22 KV" b3="ST401" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18370</SeqNum>
    <Name>Hunterstown.CT101+CT201</Name>
    <LastEdit Timestamp="2026-03-13T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="18 KV" b3="CT101" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="18 KV" b3="CT201" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="500 KV" b3="GB1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="500 KV" b3="GB1-82" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUNTERST" b2="500 KV" b3="GSU101" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUNTERST" b2="500 KV" b3="GSU201" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18380</SeqNum>
    <Name>Hunterstown.CT301+ST401</Name>
    <LastEdit Timestamp="2026-03-13T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="18 KV" b3="CT301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="500 KV" b3="GB1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="500 KV" b3="GB2-42" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUNTERST" b2="500 KV" b3="GSU301" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUNTERST" b2="500 KV" b3="GSU401" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="22 KV" b3="ST401" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18390</SeqNum>
    <Name>Hunterstown.CC</Name>
    <LastEdit Timestamp="2026-03-13T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="18 KV" b3="CT101" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="18 KV" b3="CT201" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="18 KV" b3="CT301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="500 KV" b3="GB1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="500 KV" b3="GB1-82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="500 KV" b3="GB2-42" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="22 KV" b3="ST401" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18400</SeqNum>
    <Name>L500.Conemaugh-Vinco.5006</Name>
    <LastEdit Timestamp="2026-04-17T14:31:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONEMAUG" b2="500 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONEMAUG" b2="500 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINCO" b2="500 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINCO" b2="500 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONEMAUG" b2="500 KV" b3="CNM-VIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18410</SeqNum>
    <Name>L500.PeachBottom-RockSprings.5014</Name>
    <LastEdit Timestamp="2025-08-21T13:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="205 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="215 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="PEACHBOT" b2="500 KV" b3="PEA-ROC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKSPRI" b2="500 KV" b3="52-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKSPRI" b2="500 KV" b3="52-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18430</SeqNum>
    <Name>RockSprings.CT1+CT2</Name>
    <LastEdit Timestamp="2026-03-13T09:45:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKSPRI" b2="500 KV" b3="52-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKSPRI" b2="500 KV" b3="52-4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROCKSPRI" b2="18 KV" b3="CT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROCKSPRI" b2="18 KV" b3="CT2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKSPRI" b2="500 KV" b3="TR12-P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18440</SeqNum>
    <Name>RockSprings.CT3+CT4</Name>
    <LastEdit Timestamp="2026-03-13T09:46:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKSPRI" b2="500 KV" b3="52-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKSPRI" b2="500 KV" b3="52-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROCKSPRI" b2="18 KV" b3="CT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROCKSPRI" b2="18 KV" b3="CT4" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKSPRI" b2="500 KV" b3="TR34-P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18450</SeqNum>
    <Name>Lakewood.CT1</Name>
    <LastEdit Timestamp="2026-03-13T09:38:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEWOOD" b2="230 KV" b3="CT1CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LAKEWOOD" b2="18 KV" b3="OCEAN C1" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKEWOOD" b2="230 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18460</SeqNum>
    <Name>Lakewood.CT2</Name>
    <LastEdit Timestamp="2026-03-13T09:38:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEWOOD" b2="230 KV" b3="CT2CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LAKEWOOD" b2="18 KV" b3="OCEAN C2" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKEWOOD" b2="230 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18470</SeqNum>
    <Name>L500.Hosensack-SteelCity.5032</Name>
    <LastEdit Timestamp="2025-05-08T12:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="500 KV" b3="ALBU" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOSENSAC" b2="500 KV" b3="HOS-STE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="500 KV" b3="LAUS_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELCTY" b2="500 KV" b3="BEP1_HOS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELCTY" b2="500 KV" b3="HOSE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18480</SeqNum>
    <Name>SteelCity.CC1</Name>
    <LastEdit Timestamp="2026-03-13T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="STEELCTY" b2="18 KV" b3="BETH 4CC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="STEELCTY" b2="13 KV" b3="BETH CT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="STEELCTY" b2="13 KV" b3="BETH CT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="STEELCTY" b2="13 KV" b3="BETH CT3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELCTY" b2="500 KV" b3="BKR1-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="STEELCTY" b2="500 KV" b3="CT1 GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="STEELCTY" b2="500 KV" b3="CT2 GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="STEELCTY" b2="500 KV" b3="CT3 GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="STEELCTY" b2="500 KV" b3="ST1 GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18510</SeqNum>
    <Name>SteelCity.CC2</Name>
    <LastEdit Timestamp="2026-03-13T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELCTY" b2="230 KV" b3="BEP2QUA2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="STEELCTY" b2="18 KV" b3="BETH 8CC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="STEELCTY" b2="13 KV" b3="BETH CT5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="STEELCTY" b2="13 KV" b3="BETH CT6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="STEELCTY" b2="13 KV" b3="BETH CT7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELCTY" b2="500 KV" b3="BKR5-8" />
      <ContingencyEquipment Action="X" Type="XF" b1="STEELCTY" b2="500 KV" b3="CT5 GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="STEELCTY" b2="500 KV" b3="CT6 GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="STEELCTY" b2="500 KV" b3="CT7 GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELCTY" b2="230 KV" b3="QUAR1_E" />
      <ContingencyEquipment Action="X" Type="XF" b1="STEELCTY" b2="230 KV" b3="ST2 GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18520</SeqNum>
    <Name>L230.Linwood-Post.220-97A</Name>
    <LastEdit Timestamp="2026-03-13T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="215" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINWDPE" b2="230 KV" b3="LIN-POS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POST" b2="230 KV" b3="475" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POST" b2="230 KV" b3="785" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18540</SeqNum>
    <Name>L230.Linwood-Chichester.220-43</Name>
    <LastEdit Timestamp="2024-12-06T10:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="230 KV" b3="435 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICHEST" b2="230 KV" b3="CHI-LIN3" />
      <ContingencyEquipment Action="S" Type="SD" b1="CHICHEST" b2="230 KV" b3="L22043" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="315" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="325" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18560</SeqNum>
    <Name>L230.Linwood-PhillipsIsl.220-86 + Phillips.STM.CT3</Name>
    <LastEdit Timestamp="2025-12-01T13:49:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="215" />
      <ContingencyEquipment Action="S" Type="SD" b1="LINWDPE" b2="230 KV" b3="220-86" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="315" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="4 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINWDPE" b2="230 KV" b3="4-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINWDPE" b2="18 KV" b3="4-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINWDPE" b2="18 KV" b3="4-T" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINWDPE" b2="18 KV" b3="CT3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINWDPE" b2="18 KV" b3="LINW2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINWDPE" b2="18 KV" b3="STM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18570</SeqNum>
    <Name>L230.Linwood-PhillipsIsl.220-87 + Phillips.CT1.CT2</Name>
    <LastEdit Timestamp="2025-01-09T14:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="2 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="LINWDPE" b2="230 KV" b3="220-87" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="225" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="325" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="6 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINWDPE" b2="18 KV" b3="CT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINWDPE" b2="18 KV" b3="CT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18590</SeqNum>
    <Name>Linwood.Phillips Island.CT3+STM</Name>
    <LastEdit Timestamp="2026-03-13T09:37:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="4 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINWDPE" b2="230 KV" b3="4-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINWDPE" b2="18 KV" b3="4-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINWDPE" b2="18 KV" b3="4-T" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINWDPE" b2="18 KV" b3="CT3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="18 KV" b3="CT3 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINWDPE" b2="18 KV" b3="LINW2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINWDPE" b2="18 KV" b3="STM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="18 KV" b3="STM CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18600</SeqNum>
    <Name>Linwood.PhillipsIsland.CT2</Name>
    <LastEdit Timestamp="2026-03-13T09:40:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="5 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINWDPE" b2="18 KV" b3="CT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="18 KV" b3="CT2 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINWDPE" b2="230 KV" b3="GSU5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18610</SeqNum>
    <Name>Linwood.PhillipsIsland.CT1</Name>
    <LastEdit Timestamp="2026-03-13T09:40:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="230 KV" b3="6 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINWDPE" b2="18 KV" b3="CT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWDPE" b2="18 KV" b3="CT1 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINWDPE" b2="230 KV" b3="GSU6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINWDPE" b2="18 KV" b3="LINW1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18620</SeqNum>
    <Name>L69.Lewis-Huron.0703</Name>
    <LastEdit Timestamp="2026-03-12T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HURON" b2="69 KV" b3="B CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HURON" b2="69 KV" b3="D CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HURON" b2="69 KV" b3="HUR-LEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="OCB B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18630</SeqNum>
    <Name>L69.Huron-Ontario.0734</Name>
    <LastEdit Timestamp="2026-03-12T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HURON" b2="69 KV" b3="H CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HURON" b2="69 KV" b3="HUR-ONT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HURON" b2="69 KV" b3="K CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONTARIO" b2="69 KV" b3="OCB E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18640</SeqNum>
    <Name>L230.Mickleton-Monroe.2316</Name>
    <LastEdit Timestamp="2026-03-13T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="HP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="JN" />
      <ContingencyEquipment Action="L" Type="LN" b1="MICKLETO" b2="230 KV" b3="MIC-MON6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="230 KV" b3="BUSOCBAA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="230 KV" b3="JJ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18650</SeqNum>
    <Name>345/230.ErieSouth.T5</Name>
    <LastEdit Timestamp="2025-12-26T22:50:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="345 KV" b3="128 B1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ERIES" b2="345 KV" b3="5 TX  3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="230 KV" b3="NO5TX230" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18660</SeqNum>
    <Name>345/230.ErieSouth.T8</Name>
    <LastEdit Timestamp="2026-03-13T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="345 KV" b3="128 B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="230 KV" b3="128 B3" />
      <ContingencyEquipment Action="X" Type="XF" b1="ERIES" b2="345 KV" b3="NO8 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18670</SeqNum>
    <Name>L230.EastTowanda-Canyon-NMeshoppen</Name>
    <LastEdit Timestamp="2025-08-19T10:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CANYON" b2="230 KV" b3="CAN-NME" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CANYON" b2="230 KV" b3="CNYOILGS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="230 KV" b3="B44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="230 KV" b3="B62" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANYON" b2="230 KV" b3="CAN-EAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="230 KV" b3="B25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="230 KV" b3="B60" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18680</SeqNum>
    <Name>230/69.Cardiff.T1</Name>
    <LastEdit Timestamp="2026-03-13T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CARDIFF" b2="230 KV" b3="CARD #1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="T CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="V CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="69 KV" b3="XFMRGCBA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18690</SeqNum>
    <Name>230/69.Cardiff.T2</Name>
    <LastEdit Timestamp="2026-03-13T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CARDIFF" b2="230 KV" b3="CARD #2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="GQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="W CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="69 KV" b3="XFMRGCBB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18700</SeqNum>
    <Name>Cardiff.SVC</Name>
    <LastEdit Timestamp="2026-03-13T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="BV CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CARDIFF" b2="230 KV" b3="CARD SVC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="U CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18710</SeqNum>
    <Name>Ronco.CC</Name>
    <LastEdit Timestamp="2025-07-14T15:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RONCO" b2="500 KV" b3="1EY-CB-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RONCO" b2="500 KV" b3="1EY-CB-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RONCO" b2="500 KV" b3="1EY-CB-C" />
      <ContingencyEquipment Action="X" Type="XF" b1="RONCO" b2="500 KV" b3="1EY-TF-A" />
      <ContingencyEquipment Action="X" Type="XF" b1="RONCO" b2="500 KV" b3="1EY-TF-B" />
      <ContingencyEquipment Action="X" Type="XF" b1="RONCO" b2="500 KV" b3="1EY-TF-C" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RONCO" b2="18 KV" b3="CT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RONCO" b2="18 KV" b3="CT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RONCO" b2="18 KV" b3="STM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18720</SeqNum>
    <Name>Ronco.CT1</Name>
    <LastEdit Timestamp="2026-03-16T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RONCO" b2="500 KV" b3="1EY-CB-A" />
      <ContingencyEquipment Action="X" Type="XF" b1="RONCO" b2="500 KV" b3="1EY-TF-A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RONCO" b2="18 KV" b3="CT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18730</SeqNum>
    <Name>Ronco.CT2</Name>
    <LastEdit Timestamp="2026-03-16T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RONCO" b2="500 KV" b3="1EY-CB-B" />
      <ContingencyEquipment Action="X" Type="XF" b1="RONCO" b2="500 KV" b3="1EY-TF-B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RONCO" b2="18 KV" b3="CT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18740</SeqNum>
    <Name>Ronco.STM</Name>
    <LastEdit Timestamp="2026-03-16T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RONCO" b2="500 KV" b3="1EY-CB-C" />
      <ContingencyEquipment Action="X" Type="XF" b1="RONCO" b2="500 KV" b3="1EY-TF-C" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RONCO" b2="18 KV" b3="STM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18750</SeqNum>
    <Name>230/69.Richmond.T7</Name>
    <LastEdit Timestamp="2026-03-16T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="69 KV" b3="130 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="69 KV" b3="140 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="230 KV" b3="285 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="230 KV" b3="525 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="RICH PE" b2="230 KV" b3="RICH 7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18760</SeqNum>
    <Name>Hunlock.U3</Name>
    <LastEdit Timestamp="2026-03-16T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNLOCK" b2="69 KV" b3="52T3" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUNLOCK" b2="69 KV" b3="GEN3XFMR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNLOCK" b2="13 KV" b3="HUNL_3ST" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18770</SeqNum>
    <Name>Hunlock.U4</Name>
    <LastEdit Timestamp="2026-03-16T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HUNLOCK" b2="69 KV" b3="GEN4XFMR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNLOCK" b2="69 KV" b3="GEN4_W" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNLOCK" b2="13 KV" b3="HUNL_4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18780</SeqNum>
    <Name>L115.WindyEdgeEast-SummerField-ETowson.110517</Name>
    <LastEdit Timestamp="2025-12-26T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="E TOWSON" b2="115 KV" b3="14TR517" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="E TOWSON" b2="115 KV" b3="23TR518" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="E TOWSON" b2="115 KV" b3="5TR517" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SHAWANRD" b2="115 KV" b3="1-2TIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHAWANRD" b2="115 KV" b3="2TR-517" />
      <ContingencyEquipment Action="L" Type="LN" b1="E TOWSON" b2="115 KV" b3="ETO-SUM7" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHAWANRD" b2="115 KV" b3="SHA-SUM7" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUMMERFD" b2="115 KV" b3="SUM-WIN7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110517" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18790</SeqNum>
    <Name>L115.WindyEdgeEast-SummerField-ETowson.110518</Name>
    <LastEdit Timestamp="2025-12-26T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="E TOWSON" b2="115 KV" b3="14TR517" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="E TOWSON" b2="115 KV" b3="23TR518" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="E TOWSON" b2="115 KV" b3="5TR517" />
      <ContingencyEquipment Action="L" Type="LN" b1="E TOWSON" b2="115 KV" b3="ETO-SUM8" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SHAWANRD" b2="115 KV" b3="1-2TIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHAWANRD" b2="115 KV" b3="1TR-518" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHAWANRD" b2="115 KV" b3="SHA-SUM8" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUMMERFD" b2="115 KV" b3="SUM-WIN8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110518" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18800</SeqNum>
    <Name>L115.PhiladelphiaRd-Erdman.110605A + PhilaRd.CT1-2</Name>
    <LastEdit Timestamp="2025-12-24T10:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ERDMAN" b2="115 KV" b3="110605A" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HIGHLAND" b2="115 KV" b3="1-2TIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HIGHLAND" b2="115 KV" b3="110605-A" />
      <ContingencyEquipment Action="L" Type="LN" b1="PHILADRD" b2="115 KV" b3="HLD-PHI5" />
      <ContingencyEquipment Action="X" Type="XF" b1="PHILADRD" b2="115 KV" b3="110-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHILADRD" b2="115 KV" b3="110-12C" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PHILADRD" b2="4 KV" b3="CT 1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PHILADRD" b2="4 KV" b3="CT 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERDMAN" b2="115 KV" b3="ERD-PHI5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18810</SeqNum>
    <Name>L115.PhiladelphiaRd-Erdman.110606A + PhilaRd.CT3-4</Name>
    <LastEdit Timestamp="2025-12-23T10:43:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ERDMAN" b2="115 KV" b3="110606A" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HIGHLAND" b2="115 KV" b3="1-2TIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HIGHLAND" b2="115 KV" b3="110606-A" />
      <ContingencyEquipment Action="L" Type="LN" b1="PHILADRD" b2="115 KV" b3="HLD-PHI6" />
      <ContingencyEquipment Action="X" Type="XF" b1="PHILADRD" b2="115 KV" b3="110-34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHILADRD" b2="115 KV" b3="110-34C" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PHILADRD" b2="4 KV" b3="CT 3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PHILADRD" b2="4 KV" b3="CT 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERDMAN" b2="115 KV" b3="ERD-PHI6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18820</SeqNum>
    <Name>L115.ConcordStreet-MonumentStreet.110563</Name>
    <LastEdit Timestamp="2025-07-23T16:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC BC" b2="115 KV" b3="110-2HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC BC" b2="115 KV" b3="568563CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONC BC" b2="115 KV" b3="CON-MON3" />
      <ContingencyEquipment Action="CL" Type="CB" b1="CONC BC" b2="13 KV" b3="TIE CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONUMEST" b2="115 KV" b3="110-2HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONUMEST" b2="115 KV" b3="563_558" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18840</SeqNum>
    <Name>PantherCreek.Nug</Name>
    <LastEdit Timestamp="2026-03-17T15:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PANTHER" b2="69 KV" b3="DUMMYGEN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PANTHER" b2="69 KV" b3="PANTR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18850</SeqNum>
    <Name>Blossburg.CT</Name>
    <LastEdit Timestamp="2025-06-18T12:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BLOSSBUR" b2="34 KV" b3="TRANSFR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BLOSSBUR" b2="34 KV" b3="TX345MOA" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BLOSSBUR" b2="13 KV" b3="UNITCT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18860</SeqNum>
    <Name>ColverPower.NUG</Name>
    <LastEdit Timestamp="2026-03-16T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="COLVERPO" b2="115 KV" b3="115_13" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COLVERPO" b2="13 KV" b3="NUG GE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLVERPO" b2="115 KV" b3="NUG115KV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18870</SeqNum>
    <Name>Cambria.Ebensburg.NUG</Name>
    <LastEdit Timestamp="2024-08-20T09:03:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIA" b2="115 KV" b3="B35" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIA" b2="115 KV" b3="B36" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMBRIA" b2="115 KV" b3="CAM-EBE" />
      <ContingencyEquipment Action="X" Type="XF" b1="EBENSBUR" b2="115 KV" b3="115_13" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EBENSBUR" b2="13 KV" b3="GEN LD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EBENSBUR" b2="13 KV" b3="NUG GE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBENSBUR" b2="13 KV" b3="NUGUNSTA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18880</SeqNum>
    <Name>ArchbaldTap.PEI.U2</Name>
    <LastEdit Timestamp="2026-03-17T15:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARCHBTAP" b2="69 KV" b3="GEN2 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ARCHBTAP" b2="69 KV" b3="GEN2 GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ARCHBTAP" b2="13 KV" b3="PEI 2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18890</SeqNum>
    <Name>L115.Ridgeway-PennTech + PennTech.Gen</Name>
    <LastEdit Timestamp="2025-12-23T10:38:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PENNTECH" b2="115 KV" b3="115_13" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PENNTECH" b2="13 KV" b3="GEN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENNTECH" b2="13 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENNTECH" b2="13 KV" b3="NUG DIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENNTECH" b2="115 KV" b3="PEN-RID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDG PN" b2="115 KV" b3="B29" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18910</SeqNum>
    <Name>L115.Eclipse-Scrubgrass + Scrubgrass.Unit</Name>
    <LastEdit Timestamp="2026-02-10T11:29:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ECLIPSE" b2="115 KV" b3="B18" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCRUBGRS" b2="115 KV" b3="115_13" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCRUBGRS" b2="13 KV" b3="AUXLD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCRUBGRS" b2="13 KV" b3="DATCENT1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCRUBGRS" b2="13 KV" b3="DATCENT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ECLIPSE" b2="115 KV" b3="ECL-SCR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SCRUBGRS" b2="13 KV" b3="GEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCRUBGRS" b2="115 KV" b3="LINE115K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCRUBGRS" b2="13 KV" b3="NUG GEN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18930</SeqNum>
    <Name>Smeco.CT</Name>
    <LastEdit Timestamp="2026-03-17T15:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SMECO" b2="13 KV" b3="4210" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SMECO" b2="13 KV" b3="SMECO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18940</SeqNum>
    <Name>L138.Christiana-NewCastle.13814</Name>
    <LastEdit Timestamp="2025-05-16T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHR138" b2="138 KV" b3="CHR-NEW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18950</SeqNum>
    <Name>L500.Belmont-FlintRun.528</Name>
    <LastEdit Timestamp="2024-06-30T14:23:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="500 KV" b3="B107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="500 KV" b3="B109" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="500 KV" b3="BEL-FLIR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="500 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="500 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18960</SeqNum>
    <Name>Motiva.CT6</Name>
    <LastEdit Timestamp="2025-01-15T18:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTIVA" b2="138 KV" b3="132 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTIVA" b2="138 KV" b3="133 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOTIVA" b2="13 KV" b3="G6" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOTIVA" b2="138 KV" b3="T6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18970</SeqNum>
    <Name>Motiva.DelawareCity.CT7</Name>
    <LastEdit Timestamp="2026-03-16T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTIVA" b2="138 KV" b3="134 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTIVA" b2="138 KV" b3="135 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOTIVA" b2="13 KV" b3="G7" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOTIVA" b2="138 KV" b3="T7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18980</SeqNum>
    <Name>L138.Motiva-Reybold.13825</Name>
    <LastEdit Timestamp="2026-03-16T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTIVA" b2="138 KV" b3="130 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTIVA" b2="138 KV" b3="135 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOTIVA" b2="138 KV" b3="MOT-REY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 138" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>18990</SeqNum>
    <Name>Clayton.DEMEC.G1.G2</Name>
    <LastEdit Timestamp="2024-09-10T13:41:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTON" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTON" b2="138 KV" b3="8260" />
      <ContingencyEquipment Action="S" Type="SD" b1="CLAYTON" b2="138 KV" b3="DUMSERIE" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLAYTON" b2="13 KV" b3="G1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLAYTON" b2="13 KV" b3="G2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLAYTON" b2="138 KV" b3="LDSMY" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLAYTON" b2="138 KV" b3="TX1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLAYTON" b2="13 KV" b3="TX1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLAYTON" b2="13 KV" b3="TX1-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19010</SeqNum>
    <Name>NorthStreetDover.CT11</Name>
    <LastEdit Timestamp="2025-06-20T15:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHST" b2="69 KV" b3="3060" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHST" b2="69 KV" b3="3070" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NORTHST" b2="69 KV" b3="DUM1AB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NORTHST" b2="12 KV" b3="G11" />
      <ContingencyEquipment Action="X" Type="XF" b1="NORTHST" b2="69 KV" b3="T11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19020</SeqNum>
    <Name>Kent.Dover.CC</Name>
    <LastEdit Timestamp="2025-09-09T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="52-G2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KENT" b2="13 KV" b3="DOVER1CT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHST" b2="69 KV" b3="3070" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHST" b2="69 KV" b3="3080" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NORTHST" b2="69 KV" b3="GF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19030</SeqNum>
    <Name>L69.Hazel-Harwood</Name>
    <LastEdit Timestamp="2026-05-12T09:46:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="69 KV" b3="BEAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="69 KV" b3="BEACPAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZELPL" b2="69 KV" b3="52M" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARWOOD" b2="69 KV" b3="HAR-HAZ" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HAZELPL" b2="69 KV" b3="HAZELFW" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAZELPL" b2="69 KV" b3="STLD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19040</SeqNum>
    <Name>ContinentalTap(WilliamsEnergy).CC</Name>
    <LastEdit Timestamp="2025-03-05T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CONTITAP" b2="69 KV" b3="2CT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONTITAP" b2="69 KV" b3="3CT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONTITAP" b2="69 KV" b3="4CT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONTITAP" b2="69 KV" b3="GEN_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONTITAP" b2="69 KV" b3="GEN_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONTITAP" b2="69 KV" b3="GEN_3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONTITAP" b2="69 KV" b3="GEN_4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONTITAP" b2="69 KV" b3="WILNU1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19050</SeqNum>
    <Name>NorthamptonEnergyNug.NUG</Name>
    <LastEdit Timestamp="2026-03-16T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NAMPTON" b2="138 KV" b3="GEN 138" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NAMPTON" b2="138 KV" b3="NUG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19190</SeqNum>
    <Name>L69.Zoar-Harbeson.6758</Name>
    <LastEdit Timestamp="2025-10-17T12:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBESON" b2="69 KV" b3="7120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBESON" b2="69 KV" b3="7170" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARBESON" b2="69 KV" b3="HAR-ZOAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZOAR" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZOAR" b2="69 KV" b3="63" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19200</SeqNum>
    <Name>L69.Huntsville-Mountain</Name>
    <LastEdit Timestamp="2025-02-25T19:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTSVIL" b2="69 KV" b3="66155" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTSVIL" b2="69 KV" b3="HUN-MOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66255" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66285" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19210</SeqNum>
    <Name>L69.Swoyersville-Glenview-Dallas-Huntsville</Name>
    <LastEdit Timestamp="2024-11-20T16:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DALLAS" b2="69 KV" b3="DAL-GLE" />
      <ContingencyEquipment Action="L" Type="LN" b1="DALLAS" b2="69 KV" b3="DAL-HUN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DALLAS" b2="13 KV" b3="LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="DALLAS" b2="69 KV" b3="XFMR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GLENVIEW" b2="69 KV" b3="66111" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENVIEW" b2="69 KV" b3="GLE-KUN" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENVIEW" b2="69 KV" b3="GLE-SWO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTSVIL" b2="69 KV" b3="66145" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KUNKLE" b2="13 KV" b3="LOAD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="KUNKLE" b2="69 KV" b3="XFMR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWOYERSV" b2="69 KV" b3="66102" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19220</SeqNum>
    <Name>L69.Swoyersville-Bunker-Wasserott-Mountain</Name>
    <LastEdit Timestamp="2025-03-14T10:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BUNKERHI" b2="69 KV" b3="BUN-GLE" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUNKERHI" b2="69 KV" b3="BUN-SWO" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUNKERHI" b2="69 KV" b3="BUN-WAS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COURTDAL" b2="69 KV" b3="66134" />
      <ContingencyEquipment Action="L" Type="LN" b1="COURTDAL" b2="69 KV" b3="COU-GAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARDENTP" b2="69 KV" b3="GAR-KIN" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARDENTP" b2="69 KV" b3="GAR-WAS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GLENVIEW" b2="69 KV" b3="66111" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLENVIEW" b2="13 KV" b3="LOAD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLENVIEW" b2="69 KV" b3="XFMR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KING UGI" b2="69 KV" b3="66117" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KING UGI" b2="69 KV" b3="66131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66295" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MOUN UGI" b2="69 KV" b3="66298" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUN UGI" b2="69 KV" b3="MOU-WAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWOYERSV" b2="69 KV" b3="6699" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19230</SeqNum>
    <Name>L69.Swoyersville-Mountain</Name>
    <LastEdit Timestamp="2026-03-16T14:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66245" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MOUN UGI" b2="69 KV" b3="66248" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUN UGI" b2="69 KV" b3="MOU-SWO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWOYERSV" b2="69 KV" b3="6695" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19240</SeqNum>
    <Name>L69.Kingston-Courtdale-Mountain</Name>
    <LastEdit Timestamp="2025-10-29T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="COURTDAL" b2="69 KV" b3="66132" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="COURTDAL" b2="69 KV" b3="66134" />
      <ContingencyEquipment Action="L" Type="LN" b1="COURTDAL" b2="69 KV" b3="COU-KIN" />
      <ContingencyEquipment Action="L" Type="LN" b1="COURTDAL" b2="69 KV" b3="COU-MOU" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KING UGI" b2="69 KV" b3="66116" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KING UGI" b2="69 KV" b3="66131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66235" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MOUN UGI" b2="69 KV" b3="66238" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19250</SeqNum>
    <Name>L69.Mountain-Plymouth.1</Name>
    <LastEdit Timestamp="2026-03-16T14:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66225" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MOUN UGI" b2="69 KV" b3="66228" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUN UGI" b2="69 KV" b3="MOU-PLY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYM UGI" b2="69 KV" b3="6690" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19260</SeqNum>
    <Name>L69.Mountain-Plymouth.2</Name>
    <LastEdit Timestamp="2026-03-16T14:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66275" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MOUN UGI" b2="69 KV" b3="66278" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUN UGI" b2="69 KV" b3="MOU-PLY2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYM UGI" b2="69 KV" b3="6680" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19270</SeqNum>
    <Name>L69.Mountain-Hunlock.1</Name>
    <LastEdit Timestamp="2025-02-26T16:19:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNLOCK" b2="69 KV" b3="18" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNLOCK" b2="69 KV" b3="HUN-MOU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66205" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MOUN UGI" b2="69 KV" b3="66208" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19280</SeqNum>
    <Name>L69.Mountain-Hunlock.2 + U5 + U6</Name>
    <LastEdit Timestamp="2026-03-16T14:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNLOCK" b2="69 KV" b3="52T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNLOCK" b2="69 KV" b3="52T6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNLOCK" b2="69 KV" b3="52U" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNLOCK" b2="13 KV" b3="HUNL_5CT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNLOCK" b2="13 KV" b3="HUNL_6CT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66250" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MOUN UGI" b2="69 KV" b3="66253" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNLOCK" b2="69 KV" b3="HUN-MOU3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19290</SeqNum>
    <Name>L69.Hunlock-Lincoln</Name>
    <LastEdit Timestamp="2026-03-17T15:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNLOCK" b2="69 KV" b3="35 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNLOCK" b2="69 KV" b3="HUN-LIN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LINC UGI" b2="69 KV" b3="6662" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19300</SeqNum>
    <Name>L69.Mountain-LoomisTap-Loomis-Hanover</Name>
    <LastEdit Timestamp="2025-09-23T13:24:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANOVER" b2="69 KV" b3="66404" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANOVER" b2="69 KV" b3="HAN-LOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOOMIS" b2="69 KV" b3="66166" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOOMIS" b2="69 KV" b3="LOO-LOOM" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOOMISTP" b2="69 KV" b3="LOO-MOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66265" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MOUN UGI" b2="69 KV" b3="66268" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19310</SeqNum>
    <Name>L69.Hunlock-Koonsville</Name>
    <LastEdit Timestamp="2025-10-16T13:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNLOCK" b2="69 KV" b3="42" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNLOCK" b2="69 KV" b3="HUN-KOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KOONSVIL" b2="69 KV" b3="66376" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19320</SeqNum>
    <Name>L69.Stanton-PopeTalbot-Exeter-Swoyersville</Name>
    <LastEdit Timestamp="2025-01-21T13:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EXETER" b2="69 KV" b3="EXE-POP2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EXETER" b2="69 KV" b3="EXE-SWO" />
      <ContingencyEquipment Action="S" Type="SD" b1="EXETER" b2="69 KV" b3="SERIES1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EXETER" b2="69 KV" b3="TRAN1 AB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="EXETER" b2="69 KV" b3="TRAN1-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POPETALB" b2="69 KV" b3="LOADDIS1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="POPETALB" b2="69 KV" b3="LOADDIS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="POPETALB" b2="69 KV" b3="POP-STA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANTON" b2="69 KV" b3="SWOY CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWOYERSV" b2="69 KV" b3="6693" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19330</SeqNum>
    <Name>L69.Plymouth-Hanover</Name>
    <LastEdit Timestamp="2025-06-25T12:49:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANOVER" b2="69 KV" b3="66413" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANOVER" b2="69 KV" b3="HAN-PLY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYM UGI" b2="69 KV" b3="6650" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19430</SeqNum>
    <Name>L765.Dumont-WiltonCenter.11215</Name>
    <LastEdit Timestamp="2025-02-25T19:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="112 WILT" b2="765 KV" b3="65I11215" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="765 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="765 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="765 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUMONT2" b2="765 KV" b3="DUM-WIL1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DUMONT2" b2="765 KV" b3="RXBG" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DUMONT2" b2="765 KV" b3="RXBH" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DUMONT2" b2="765 KV" b3="RXBI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19440</SeqNum>
    <Name>L765.Dumont-Greentown</Name>
    <LastEdit Timestamp="2025-10-02T10:48:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="765 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUMONT2" b2="765 KV" b3="DUM-GRE1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DUMONT2" b2="765 KV" b3="RXCA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DUMONT2" b2="765 KV" b3="RXCB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DUMONT2" b2="765 KV" b3="RXCC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="765 KV" b3="P1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="765 KV" b3="P2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19450</SeqNum>
    <Name>L765.Cook-Dumont</Name>
    <LastEdit Timestamp="2026-03-16T14:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="765 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOK" b2="765 KV" b3="COO-DUM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="765 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19460</SeqNum>
    <Name>L765.Rockport-Sullivan</Name>
    <LastEdit Timestamp="2025-07-27T11:05:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPOR2" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPOR2" b2="765 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKPOR2" b2="765 KV" b3="ROC-SUL1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ROCKPOR2" b2="765 KV" b3="RXDA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ROCKPOR2" b2="765 KV" b3="RXDB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ROCKPOR2" b2="765 KV" b3="RXDC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="765 KV" b3="A2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SULLIVA2" b2="765 KV" b3="RXAA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SULLIVA2" b2="765 KV" b3="RXAB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SULLIVA2" b2="765 KV" b3="RXAC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19470</SeqNum>
    <Name>L765.Jefferson-Rockport</Name>
    <LastEdit Timestamp="2026-04-16T21:40:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFERSO" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFERSO" b2="765 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JEFFERSO" b2="765 KV" b3="JEF-ROC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPOR2" b2="765 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPOR2" b2="765 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19480</SeqNum>
    <Name>L765.Greentown-Jefferson</Name>
    <LastEdit Timestamp="2025-12-05T12:08:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="765 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="765 KV" b3="N2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GREENTO2" b2="765 KV" b3="RXDA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GREENTO2" b2="765 KV" b3="RXDB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GREENTO2" b2="765 KV" b3="RXDC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFERSO" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFERSO" b2="765 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JEFFERSO" b2="765 KV" b3="JEF-GRE1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="JEFFERSO" b2="765 KV" b3="RXAA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="JEFFERSO" b2="765 KV" b3="RXAB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="JEFFERSO" b2="765 KV" b3="RXAC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19500</SeqNum>
    <Name>L765.Kammer-SouthCanton + 765/345/34.SCanton.T3</Name>
    <LastEdit Timestamp="2024-10-04T08:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KAMMER2" b2="765 KV" b3="KAM-SCA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="765 KV" b3="NN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="765 KV" b3="NN1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCANTON2" b2="765 KV" b3="3-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCANTON2" b2="345 KV" b3="3-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCANTON2" b2="34 KV" b3="3-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="345 KV" b3="C2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCANTON2" b2="34 KV" b3="LAVG" />
      <ContingencyEquipment Action="S" Type="SD" b1="SCANTON2" b2="345 KV" b3="SD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19510</SeqNum>
    <Name>L765.HangingRock-Jefferson</Name>
    <LastEdit Timestamp="2026-03-17T15:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANGING2" b2="765 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANGING2" b2="765 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANGING2" b2="765 KV" b3="HAN-JEF1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HANGING2" b2="765 KV" b3="RXBA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HANGING2" b2="765 KV" b3="RXBB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HANGING2" b2="765 KV" b3="RXBC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFERSO" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFERSO" b2="765 KV" b3="A2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="JEFFERSO" b2="765 KV" b3="RXGA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="JEFFERSO" b2="765 KV" b3="RXGB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="JEFFERSO" b2="765 KV" b3="RXGC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19520</SeqNum>
    <Name>L765.DonMarquis-HangingRock</Name>
    <LastEdit Timestamp="2025-06-06T17:10:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANGING2" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANGING2" b2="765 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANGING2" b2="765 KV" b3="HAN-MAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="765 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19530</SeqNum>
    <Name>L765.Flatlick-Gavin</Name>
    <LastEdit Timestamp="2025-02-25T19:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FLATLICK" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLATLICK" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="765 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="765 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GAVINAEP" b2="765 KV" b3="GAV-FLA1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GAVINAEP" b2="765 KV" b3="RXCA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GAVINAEP" b2="765 KV" b3="RXCB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GAVINAEP" b2="765 KV" b3="RXCC" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GAVINAEP" b2="765 KV" b3="RXCE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19540</SeqNum>
    <Name>L765.Axton-JacksonsFerry + 765/138.Axton.T1</Name>
    <LastEdit Timestamp="2026-01-21T15:20:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="AXTONAEP" b2="765 KV" b3=".  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AXTONAEP" b2="765 KV" b3="A010Q2" />
      <ContingencyEquipment Action="L" Type="LN" b1="AXTONAEP" b2="765 KV" b3="AXT-JAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AXTONAEP" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AXTONAEP" b2="138 KV" b3="G2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="AXTONAEP" b2="765 KV" b3="RXAA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="AXTONAEP" b2="765 KV" b3="RXAB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="AXTONAEP" b2="765 KV" b3="RXAC" />
      <ContingencyEquipment Action="S" Type="SD" b1="AXTONAEP" b2="138 KV" b3="SERREAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="765 KV" b3="A2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19550</SeqNum>
    <Name>L765.Broadford-JacksonsFerry+B138.Broadford.RL3</Name>
    <LastEdit Timestamp="2025-08-21T13:03:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROADFO2" b2="765 KV" b3="BRO-JAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="765 KV" b3="Q1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="765 KV" b3="Q2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="138 KV" b3="RL3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BROADFO2" b2="765 KV" b3="RXMD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BROADFO2" b2="765 KV" b3="RXME" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BROADFO2" b2="765 KV" b3="RXMF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="765 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19560</SeqNum>
    <Name>L765.Gavin-Mountaineer</Name>
    <LastEdit Timestamp="2026-03-17T15:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="765 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUNTAIN" b2="765 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUNTAIN" b2="765 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUNTAIN" b2="765 KV" b3="MOU-GAV1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19570</SeqNum>
    <Name>L765.Baker-HangingRock</Name>
    <LastEdit Timestamp="2025-02-25T19:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAKER" b2="765 KV" b3="BAK-HAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="765 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="765 KV" b3="Q2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANGING2" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANGING2" b2="765 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19580</SeqNum>
    <Name>L765.Baker-Broadford</Name>
    <LastEdit Timestamp="2026-02-10T09:39:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAKER" b2="765 KV" b3="BAK-BRO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="765 KV" b3="P1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="765 KV" b3="P2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BAKER" b2="765 KV" b3="RXGA_52" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BAKER" b2="765 KV" b3="RXGB_53" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BAKER" b2="765 KV" b3="RXGC_54" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="765 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="765 KV" b3="P1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BROADFO2" b2="765 KV" b3="RXLA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BROADFO2" b2="765 KV" b3="RXLB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BROADFO2" b2="765 KV" b3="RXLC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19590</SeqNum>
    <Name>L765.Culloden-Gavin</Name>
    <LastEdit Timestamp="2026-03-17T15:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CULLODE2" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CULLODE2" b2="765 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CULLODE2" b2="765 KV" b3="CUL-GAV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="765 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19600</SeqNum>
    <Name>L765.Culloden-Wyoming</Name>
    <LastEdit Timestamp="2026-04-27T14:46:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CULLODE2" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CULLODE2" b2="765 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CULLODE2" b2="765 KV" b3="CUL-WYO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="765 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="765 KV" b3="O" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WYOMING2" b2="765 KV" b3="R5A" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WYOMING2" b2="765 KV" b3="R5B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WYOMING2" b2="765 KV" b3="R5C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="765 KV" b3="RB5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WYOMING2" b2="765 KV" b3="RB5SPABC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19610</SeqNum>
    <Name>L765.Baker-Culloden</Name>
    <LastEdit Timestamp="2025-06-04T13:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="765 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="765 KV" b3="Q1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CULLODE2" b2="765 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CULLODE2" b2="765 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CULLODE2" b2="765 KV" b3="CUL-BAK1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19630</SeqNum>
    <Name>L765.Amos-Mountaineer</Name>
    <LastEdit Timestamp="2026-03-16T14:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="765 KV" b3="AMO-MOU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="U1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUNTAIN" b2="765 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUNTAIN" b2="765 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19640</SeqNum>
    <Name>L765.Amos-Culloden</Name>
    <LastEdit Timestamp="2026-03-16T14:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="765 KV" b3="AMO-CUL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="S2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CULLODE2" b2="765 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CULLODE2" b2="765 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19660</SeqNum>
    <Name>L765.Maliszewski-Marysville</Name>
    <LastEdit Timestamp="2026-03-17T15:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MALISZEW" b2="765 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="MALISZEW" b2="765 KV" b3="MAL-MAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="765 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="765 KV" b3="A2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MARYSVI2" b2="765 KV" b3="RSAG" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MARYSVI2" b2="765 KV" b3="RSAH" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MARYSVI2" b2="765 KV" b3="RSAI" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MARYSVI2" b2="765 KV" b3="RSAJ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19670</SeqNum>
    <Name>L765.Cloverdale-JoshuaFalls</Name>
    <LastEdit Timestamp="2025-01-22T08:54:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="765 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="765 KV" b3="AA2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVERD2" b2="765 KV" b3="CLO-JOS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="765 KV" b3="RAA2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CLOVERD2" b2="765 KV" b3="RXOD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CLOVERD2" b2="765 KV" b3="RXOE" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CLOVERD2" b2="765 KV" b3="RXOF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOSHUAF2" b2="765 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19680</SeqNum>
    <Name>L765.JacksonsFerry-Cloverdale + 138CB.JF.L</Name>
    <LastEdit Timestamp="2025-07-11T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="765 KV" b3="CC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="765 KV" b3="CC2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVERD2" b2="765 KV" b3="CLO-JAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="765 KV" b3="RCC2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CLOVERD2" b2="765 KV" b3="RXNA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CLOVERD2" b2="765 KV" b3="RXNB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CLOVERD2" b2="765 KV" b3="RXNC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="765 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19690</SeqNum>
    <Name>L765.Rockport-RockportWorks.2</Name>
    <LastEdit Timestamp="2025-12-24T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKPOR2" b2="765 KV" b3="ROC-ROC2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKPWKS" b2="765 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPWKS" b2="138 KV" b3="T7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPWKS" b2="765 KV" b3="TB7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19710</SeqNum>
    <Name>L765.Flatlick-Marysville</Name>
    <LastEdit Timestamp="2026-03-18T17:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FLATLICK" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLATLICK" b2="765 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="765 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARYSVI2" b2="765 KV" b3="MAR-FLA1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MARYSVI2" b2="765 KV" b3="RSDD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MARYSVI2" b2="765 KV" b3="RSDE" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MARYSVI2" b2="765 KV" b3="RSDF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19720</SeqNum>
    <Name>L500.Broadford-Sullivan (TVA) Tie</Name>
    <LastEdit Timestamp="2025-11-06T14:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROADFO2" b2="500 KV" b3="BRO-SUL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="765 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="765 KV" b3="P2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BROADFO2" b2="765 KV" b3="T6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA" b2="500 KV" b3="5014" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SULLIVA" b2="500 KV" b3="5017" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19730</SeqNum>
    <Name>L500.Nagel-PhippsBend (TVA)</Name>
    <LastEdit Timestamp="2024-08-20T11:38:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="500 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="500 KV" b3="H2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NAGELAEP" b2="500 KV" b3="NAG-PHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHIPPB" b2="500 KV" b3="5014" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHIPPB" b2="500 KV" b3="5018" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19740</SeqNum>
    <Name>L500.Nagel-Sullivan (TVA) Tie</Name>
    <LastEdit Timestamp="2025-01-30T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="500 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="500 KV" b3="J1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NAGELAEP" b2="500 KV" b3="NAG-SUL" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SULLIVA" b2="500 KV" b3="5063" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA" b2="500 KV" b3="5068" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19750</SeqNum>
    <Name>138/69.Tidd.T12</Name>
    <LastEdit Timestamp="2024-05-14T09:17:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="69 KV" b3="AL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="X" Type="XF" b1="TIDD_AEP" b2="138 KV" b3="T12XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19760</SeqNum>
    <Name>L500.JacksonsFerry-Antioch(DUKE)Tie+765/500.JF.T1</Name>
    <LastEdit Timestamp="2024-10-02T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ANTIOCH4" b2="500 KV" b3="12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANTIOCH4" b2="500 KV" b3="22" />
      <ContingencyEquipment Action="X" Type="XF" b1="JACKSONS" b2="765 KV" b3=".  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="765 KV" b3="D1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSONS" b2="500 KV" b3="JAC-ANT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19780</SeqNum>
    <Name>L345.Olive-GreenAcres.6615</Name>
    <LastEdit Timestamp="2025-10-07T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENACR" b2="345 KV" b3="1516" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENACR" b2="345 KV" b3="1517" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRACOLIV" b2="345 KV" b3="GRA-GREE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRACOLIV" b2="345 KV" b3="GRA-OLIV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19790</SeqNum>
    <Name>L345.Desoto-Whippleditch</Name>
    <LastEdit Timestamp="2026-05-05T14:17:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DESOTO" b2="345 KV" b3="DES-WHPL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHPLDICH" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHPLDICH" b2="345 KV" b3="D2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19800</SeqNum>
    <Name>L345.Sorenson-Keystone</Name>
    <LastEdit Timestamp="2025-03-05T16:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTNE" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTNE" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SORENSON" b2="345 KV" b3="SOR-KEY1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19810</SeqNum>
    <Name>L345.Desoto-Sorenson</Name>
    <LastEdit Timestamp="2026-03-16T14:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="345 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DESOTO" b2="345 KV" b3="DES-SOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="D2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19820</SeqNum>
    <Name>L345.Desoto-Losantville</Name>
    <LastEdit Timestamp="2026-03-16T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="345 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DESOTO" b2="345 KV" b3="DES-LOS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOSANTVL" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOSANTVL" b2="345 KV" b3="D1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19830</SeqNum>
    <Name>L345.Desoto-TannersCreek</Name>
    <LastEdit Timestamp="2025-01-06T16:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DESOTO" b2="345 KV" b3="DES-TAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="P1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="P2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19840</SeqNum>
    <Name>L345.Desoto-FallCreek</Name>
    <LastEdit Timestamp="2026-03-17T15:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DESOTO" b2="345 KV" b3="DES-FAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLCREE" b2="345 KV" b3="K2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19850</SeqNum>
    <Name>L345.Dumont-TwinBranch.1</Name>
    <LastEdit Timestamp="2026-03-17T15:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DUMONT2" b2="345 KV" b3="DUM-TWI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="345 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="345 KV" b3="F2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="345 KV" b3="L1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="345 KV" b3="LM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19860</SeqNum>
    <Name>L345.Dumont-TwinBranch.2</Name>
    <LastEdit Timestamp="2026-03-17T15:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DUMONT2" b2="345 KV" b3="DUM-TWI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="345 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="345 KV" b3="E2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="345 KV" b3="K1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="345 KV" b3="KM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19870</SeqNum>
    <Name>L345.Dequine-Eugene</Name>
    <LastEdit Timestamp="2026-03-17T15:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEQUINE" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEQUINE" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEQUINE" b2="345 KV" b3="DEQ-EUG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EUGENE" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EUGENE" b2="345 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19890</SeqNum>
    <Name>L345.Cook-Olive</Name>
    <LastEdit Timestamp="2026-03-17T15:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COOK" b2="345 KV" b3="COO-OLI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="M2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="345 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19900</SeqNum>
    <Name>L345.JacksonRoad-TwinBranch</Name>
    <LastEdit Timestamp="2024-10-31T08:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="345 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="345 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSONR" b2="345 KV" b3="JAC-TWI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="345 KV" b3="J1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="345 KV" b3="JM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19930</SeqNum>
    <Name>L345.Argenta-TwinBranch</Name>
    <LastEdit Timestamp="2026-03-17T15:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGENTA2" b2="345 KV" b3="34H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGENTA2" b2="345 KV" b3="34R8" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARGENTA2" b2="345 KV" b3="ANG-DUM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="345 KV" b3="K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="345 KV" b3="KM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>19980</SeqNum>
    <Name>L345.DuntonLake-RobisonPark</Name>
    <LastEdit Timestamp="2025-08-04T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNTONLK" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNTONLK" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUNTONLK" b2="345 KV" b3="DUN-ROBI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="345 KV" b3="PM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="345 KV" b3="PM2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20010</SeqNum>
    <Name>L345.DuntonLake-Hiple (NIPS) Tie</Name>
    <LastEdit Timestamp="2025-08-19T10:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNTONLK" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNTONLK" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUNTONLK" b2="345 KV" b3="DUN-HIPL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34525-26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34526" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20020</SeqNum>
    <Name>L345.AllenIM-Sorenson</Name>
    <LastEdit Timestamp="2026-03-17T15:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENIM" b2="345 KV" b3="ALL-SOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="F2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20030</SeqNum>
    <Name>L345.AllenIM-RobisonPark.1</Name>
    <LastEdit Timestamp="2026-03-17T15:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENIM" b2="345 KV" b3="ALL-ROB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="345 KV" b3="M1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="345 KV" b3="MM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20040</SeqNum>
    <Name>L345.Meridian-Twinbranch</Name>
    <LastEdit Timestamp="2026-03-18T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MERIDIAN" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERIDIAN" b2="345 KV" b3="MER-TWI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="345 KV" b3="J2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="345 KV" b3="JM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20050</SeqNum>
    <Name>L345.Jefferson-CliftyCreek</Name>
    <LastEdit Timestamp="2026-03-18T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFERSO" b2="345 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="JEFFERSO" b2="345 KV" b3="JEF-CLI1" />
      <ContingencyEquipment Action="X" Type="XF" b1="JEFFERSO" b2="765 KV" b3="XF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20060</SeqNum>
    <Name>L345.Eugene-Sullivan</Name>
    <LastEdit Timestamp="2024-09-30T14:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EUGENE" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EUGENE" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EUGENE" b2="345 KV" b3="EUG-SUL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="345 KV" b3="C1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20080</SeqNum>
    <Name>L345.Sullivan-Dequine</Name>
    <LastEdit Timestamp="2026-03-18T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEQUINE" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEQUINE" b2="345 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEQUINE" b2="345 KV" b3="DEQ-SUL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="345 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20120</SeqNum>
    <Name>L345.EastLima-FostoriaCentral</Name>
    <LastEdit Timestamp="2026-03-18T16:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMA" b2="345 KV" b3="ELI-FOS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="345 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="345 KV" b3="P2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="345 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20130</SeqNum>
    <Name>L345.EastLima-SouthWestLima</Name>
    <LastEdit Timestamp="2026-03-18T16:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMA" b2="345 KV" b3="ELI-SWL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="345 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="345 KV" b3="P1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="345 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20150</SeqNum>
    <Name>L345.CantonCentral-SouthEastCanton</Name>
    <LastEdit Timestamp="2026-03-17T15:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CANTONCE" b2="345 KV" b3="CAN-SEC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="345 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="345 KV" b3="L1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="345 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="345 KV" b3="N2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20160</SeqNum>
    <Name>L345.CantonCentral-SouthCanton</Name>
    <LastEdit Timestamp="2026-03-17T15:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CANTONCE" b2="345 KV" b3="CAN-SCA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="345 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="345 KV" b3="L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="345 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20170</SeqNum>
    <Name>L345.CantonCentral-Stemple</Name>
    <LastEdit Timestamp="2025-03-24T10:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CANTONCE" b2="345 KV" b3="CAN-STEM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="345 KV" b3="K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEMPLE" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEMPLE" b2="345 KV" b3="N1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20180</SeqNum>
    <Name>L345.Beacon-Roberts.2</Name>
    <LastEdit Timestamp="2024-11-13T09:33:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEACON" b2="345 KV" b3="BEA-ROBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEACON" b2="345 KV" b3="H007Q5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEACON" b2="345 KV" b3="H007Q8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="345 KV" b3="B CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20190</SeqNum>
    <Name>L345.Hayden-Celtic</Name>
    <LastEdit Timestamp="2025-12-09T16:03:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="345 KV" b3="H021A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="345 KV" b3="H021A5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYDEN" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYDEN" b2="345 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CELTIC" b2="345 KV" b3="CEL-HAYD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20220</SeqNum>
    <Name>L345.Conesville-HyattCS</Name>
    <LastEdit Timestamp="2026-03-17T15:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="345 KV" b3="301C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="345 KV" b3="301N" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONESVIL" b2="345 KV" b3="CON-HYA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="H1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20240</SeqNum>
    <Name>L345.Marysville-Tangy(OE)</Name>
    <LastEdit Timestamp="2026-03-18T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="345 KV" b3="K2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARYSVI2" b2="345 KV" b3="MAR-TAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="345 KV" b3="B81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="345 KV" b3="B91" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20250</SeqNum>
    <Name>L345.Marysville-SouthWestLima</Name>
    <LastEdit Timestamp="2024-10-18T13:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="345 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="345 KV" b3="H2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARYSVI2" b2="345 KV" b3="MAR-SWL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="345 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20260</SeqNum>
    <Name>L345.Gristmill-Shelby</Name>
    <LastEdit Timestamp="2025-04-18T17:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRISTMIL" b2="345 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRISTMIL" b2="345 KV" b3="GRI-SHLB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRISTMIL" b2="345 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="345 KV" b3="HH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="345 KV" b3="JJ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20270</SeqNum>
    <Name>L345.Bixby-Kirk</Name>
    <LastEdit Timestamp="2025-01-28T17:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BIXBY" b2="345 KV" b3="BIX-KIR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="345 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="345 KV" b3="F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="345 KV" b3="D CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="345 KV" b3="D2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20290</SeqNum>
    <Name>L345.Beatty-Cyprus</Name>
    <LastEdit Timestamp="2024-11-12T15:33:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="345 KV" b3="304C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="345 KV" b3="304E" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEATTY" b2="345 KV" b3="BEA-CYPR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="345 KV" b3="H017Y2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="345 KV" b3="H017Y8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20310</SeqNum>
    <Name>L345.Beatty-Cole</Name>
    <LastEdit Timestamp="2024-05-29T10:11:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="345 KV" b3="302C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="345 KV" b3="302E" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEATTY" b2="345 KV" b3="BEA-COLE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="345 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20320</SeqNum>
    <Name>L345.Beatty-Adkins</Name>
    <LastEdit Timestamp="2025-05-16T12:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADKINS" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADKINS" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="345 KV" b3="304C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="345 KV" b3="304W" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEATTY" b2="345 KV" b3="BEA-ADK1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20360</SeqNum>
    <Name>L345.OhioCentral-MuskingumRiver</Name>
    <LastEdit Timestamp="2026-03-18T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MUSKING2" b2="345 KV" b3="MUS-OHI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SJ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="345 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="345 KV" b3="L1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20380</SeqNum>
    <Name>138/69.Wallen.T2</Name>
    <LastEdit Timestamp="2026-05-08T14:48:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WALLEN" b2="69 KV" b3="AB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WALLEN" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALLEN" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20400</SeqNum>
    <Name>L345.Harmon(FE)-SouthCanton</Name>
    <LastEdit Timestamp="2026-03-18T17:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="345 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="345 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARMONOE" b2="345 KV" b3="HAR-SCAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20410</SeqNum>
    <Name>L345.SouthCanton-SouthEastCanton</Name>
    <LastEdit Timestamp="2026-03-18T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCANTON2" b2="345 KV" b3="SCA-SEC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="345 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="345 KV" b3="N1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20420</SeqNum>
    <Name>L345.MuskingumRiver-WestMillersport.1</Name>
    <LastEdit Timestamp="2024-10-18T13:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MUSKING2" b2="345 KV" b3="MUS-WMI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="345 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="345 KV" b3="L1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20440</SeqNum>
    <Name>L345.MuskingumRiver-WestMillersport.2</Name>
    <LastEdit Timestamp="2024-10-18T13:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MUSKING2" b2="345 KV" b3="MUS-WMI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="345 KV" b3="M1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20470</SeqNum>
    <Name>L345.Kammer-Lamping</Name>
    <LastEdit Timestamp="2025-01-31T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="345 KV" b3="DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="345 KV" b3="DD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMPING" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMPING" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KAMMER2" b2="345 KV" b3="KAM-LAM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20480</SeqNum>
    <Name>L345.Muskingum River-Waterford</Name>
    <LastEdit Timestamp="2026-03-18T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MUSKING2" b2="345 KV" b3="MUS-WAT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFOR" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFOR" b2="345 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20490</SeqNum>
    <Name>L345.Beverly-Holloway</Name>
    <LastEdit Timestamp="2026-03-18T16:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEVERLY2" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEVERLY2" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEVERLY2" b2="345 KV" b3="BEV-HOL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="345 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="345 KV" b3="N2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20500</SeqNum>
    <Name>L345.Beverly(IPP)-MuskingumRiver</Name>
    <LastEdit Timestamp="2026-03-18T16:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEVERLY2" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEVERLY2" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEVERLY2" b2="345 KV" b3="BEV-MUS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="ST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20510</SeqNum>
    <Name>L345.Sporn-Waterford</Name>
    <LastEdit Timestamp="2026-03-18T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="CC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="CC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPORNAEP" b2="345 KV" b3="SPO-WAT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFOR" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFOR" b2="345 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20520</SeqNum>
    <Name>L345.Cloverdale-MattFunk</Name>
    <LastEdit Timestamp="2026-03-18T16:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVERD2" b2="345 KV" b3="CLO-MAT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="345 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="345 KV" b3="P1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="345 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20540</SeqNum>
    <Name>L345.KanawhaRiver-MattFunk</Name>
    <LastEdit Timestamp="2024-12-06T10:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KANAWHAR" b2="345 KV" b3="KAN-MAT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="345 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="345 KV" b3="Q2" />
      <ContingencyEquipment Action="S" Type="SD" b1="KANAWHAR" b2="345 KV" b3="SC1-CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="345 KV" b3="A2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20550</SeqNum>
    <Name>L345.KanawhaRiver-Sporn</Name>
    <LastEdit Timestamp="2026-03-18T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="345 KV" b3="EE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="345 KV" b3="EE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KANAWHAR" b2="345 KV" b3="KAN-SPO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="DD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20560</SeqNum>
    <Name>L345.Amos-KanawhaRiver</Name>
    <LastEdit Timestamp="2026-03-18T16:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="345 KV" b3="AMO-KAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="345 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="345 KV" b3="J2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="345 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="345 KV" b3="Q1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20570</SeqNum>
    <Name>L345.Amos-Sporn</Name>
    <LastEdit Timestamp="2026-03-18T16:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="345 KV" b3="AMO-SPO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="345 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="345 KV" b3="J1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="CC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="CC2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20590</SeqNum>
    <Name>L345.Marquis-Stuart</Name>
    <LastEdit Timestamp="2025-01-30T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="345 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARQUIS2" b2="345 KV" b3="MAR-STUA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUART2" b2="345 KV" b3="VV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUART2" b2="345 KV" b3="WW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20610</SeqNum>
    <Name>L345.Waterford-PSEGGlob.2</Name>
    <LastEdit Timestamp="2026-03-18T17:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="PSEGGLOB" b2="18 KV" b3="7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PSEGGLOB" b2="18 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PSEGGLOB" b2="345 KV" b3="8_CEE468" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PSEGGLOB" b2="345 KV" b3="TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFOR" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFOR" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="WATERFOR" b2="345 KV" b3="WAT-PSE2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20620</SeqNum>
    <Name>L345.Waterford-PSEGGlob.1</Name>
    <LastEdit Timestamp="2026-03-18T17:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="PSEGGLOB" b2="22 KV" b3="5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PSEGGLOB" b2="18 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PSEGGLOB" b2="345 KV" b3="6_02F2FB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PSEGGLOB" b2="345 KV" b3="TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFOR" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFOR" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="WATERFOR" b2="345 KV" b3="WAT-PSE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20640</SeqNum>
    <Name>L345.KygerCreek-Sporn.1</Name>
    <LastEdit Timestamp="2026-01-06T11:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="AA1CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPORNAEP" b2="345 KV" b3="SPO-KYG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20650</SeqNum>
    <Name>L345.Dumont-Stillwell (NIPS)</Name>
    <LastEdit Timestamp="2025-05-08T12:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DUMONT2" b2="345 KV" b3="DUM-STI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="345 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="345 KV" b3="F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STILLWEL" b2="345 KV" b3="01" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STILLWEL" b2="345 KV" b3="01-W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20670</SeqNum>
    <Name>L345.FallCreek-Sunnyside</Name>
    <LastEdit Timestamp="2026-03-18T17:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLCREE" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="L" Type="LN" b1="FALLCREE" b2="345 KV" b3="FAL-SUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNNYSID" b2="345 KV" b3="M2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20680</SeqNum>
    <Name>L345.Bunsonville-Eugene</Name>
    <LastEdit Timestamp="2026-03-18T16:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUNSONV3" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUNSONV3" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EUGENE" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EUGENE" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EUGENE" b2="345 KV" b3="EUG-BUN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20690</SeqNum>
    <Name>L345.Cayuga-Eugene</Name>
    <LastEdit Timestamp="2026-03-18T16:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA3" b2="345 KV" b3="02G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA3" b2="345 KV" b3="3502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EUGENE" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EUGENE" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EUGENE" b2="345 KV" b3="EUG-CAY1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20700</SeqNum>
    <Name>L345.Dequine-Westwood.1+345/138.Westwood.1</Name>
    <LastEdit Timestamp="2025-08-04T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEQUINE" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEQUINE" b2="345 KV" b3="D1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEQUINE" b2="345 KV" b3="DEQ-WES1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WESTWOOD" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTWOOD" b2="138 KV" b3="138345-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20710</SeqNum>
    <Name>L345.Dequine-Westwood.2</Name>
    <LastEdit Timestamp="2025-01-29T14:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEQUINE" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEQUINE" b2="345 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEQUINE" b2="345 KV" b3="DEQ-WES2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTWOOD" b2="345 KV" b3="34529" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20720</SeqNum>
    <Name>345/138.Westwood.T2</Name>
    <LastEdit Timestamp="2025-04-22T14:04:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTWOOD" b2="138 KV" b3="138345-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="WESTWOOD" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTWOOD" b2="345 KV" b3="34529" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20740</SeqNum>
    <Name>L345.Sullivan-SNYD-CaseyWest</Name>
    <LastEdit Timestamp="2026-01-28T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CASEY  3" b2="345 KV" b3="3527" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CASEY  3" b2="345 KV" b3="3528" />
      <ContingencyEquipment Action="L" Type="LN" b1="CASEY  3" b2="345 KV" b3="CAS-SNYD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SNYD" b2="345 KV" b3="RFSF_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="345 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="345 KV" b3="H1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SNYD" b2="345 KV" b3="SNY-SULL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20760</SeqNum>
    <Name>L345.FostoriaCentral-Lemoyne</Name>
    <LastEdit Timestamp="2025-06-03T11:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTORIA" b2="345 KV" b3="FOS-LEM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B34506" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20770</SeqNum>
    <Name>L345.Marquis-DOEX530</Name>
    <LastEdit Timestamp="2026-03-20T10:26:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOEX530" b2="345 KV" b3="26L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARQUIS2" b2="345 KV" b3="MAR-DOE2" />
      <ContingencyEquipment Action="S" Type="SD" b1="MARQUIS2" b2="345 KV" b3="_MARQUIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20780</SeqNum>
    <Name>L345.KygerCreek-Marquis</Name>
    <LastEdit Timestamp="2026-03-19T08:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KYGERCRE" b2="345 KV" b3="KYG-MAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20790</SeqNum>
    <Name>L345.Baker-Foothill</Name>
    <LastEdit Timestamp="2026-01-06T11:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAKER" b2="345 KV" b3="BAK-FOO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="345 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="345 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOOTHILL" b2="345 KV" b3="1_AA20BA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOOTHILL" b2="345 KV" b3="2_E4C6D3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOOTHILL" b2="18 KV" b3="UNIT 4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOOTHILL" b2="18 KV" b3="UNIT 5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20800</SeqNum>
    <Name>L345.Baker-Zelda</Name>
    <LastEdit Timestamp="2026-01-06T11:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAKER" b2="345 KV" b3="BAK-ZEL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="345 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="345 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZELDA" b2="345 KV" b3="1_DF5B55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZELDA" b2="345 KV" b3="2_623E57" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZELDA" b2="345 KV" b3="3_5E90BD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ZELDA" b2="18 KV" b3="UNIT 1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ZELDA" b2="18 KV" b3="UNIT 2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ZELDA" b2="18 KV" b3="UNIT 3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20810</SeqNum>
    <Name>L345.Beverly-DenaWashington + DenaWash.U1&amp;2&amp;3</Name>
    <LastEdit Timestamp="2026-03-18T16:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEVERLY2" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEVERLY2" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEVERLY2" b2="345 KV" b3="BEV-DEN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENAWASH" b2="345 KV" b3="EYA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENAWASH" b2="345 KV" b3="EYB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENAWASH" b2="345 KV" b3="EYC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DENAWASH" b2="18 KV" b3="UN1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DENAWASH" b2="18 KV" b3="UN2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DENAWASH" b2="18 KV" b3="UN3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20830</SeqNum>
    <Name>L345.TannersCreek-EastBend</Name>
    <LastEdit Timestamp="2025-05-16T12:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEND" b2="345 KV" b3="1583" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEND" b2="345 KV" b3="1585" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TANNERSC" b2="345 KV" b3="TAN-EBE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20840</SeqNum>
    <Name>L345.TannersCreek-Hanna.Tie</Name>
    <LastEdit Timestamp="2024-11-20T16:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAIPL" b2="345 KV" b3="27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAIPL" b2="345 KV" b3="28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="R1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="R2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TANNERSC" b2="345 KV" b3="TAN-HAN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20850</SeqNum>
    <Name>L345.Meridian-EastWhitley-Sorenson</Name>
    <LastEdit Timestamp="2026-03-18T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EWHITLEY" b2="345 KV" b3="SWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERIDIAN" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERIDIAN" b2="345 KV" b3="MER-EWH1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERIDIAN" b2="345 KV" b3="MER-SOR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERIDIAN" b2="345 KV" b3="MER-TWI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20860</SeqNum>
    <Name>L345.TannersCreek-Dearborn.1</Name>
    <LastEdit Timestamp="2025-07-11T13:15:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEARBORN" b2="345 KV" b3="DB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEARBORN" b2="345 KV" b3="DC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="N1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TANNERSC" b2="345 KV" b3="TAN-DEA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20880</SeqNum>
    <Name>L345.TannersCreek-Lawrence.2</Name>
    <LastEdit Timestamp="2024-11-20T16:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENC2" b2="345 KV" b3="52-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="S2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TANNERSC" b2="345 KV" b3="TAN-LAW2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20890</SeqNum>
    <Name>L345.TannersCreek-Lawrence.1</Name>
    <LastEdit Timestamp="2024-11-20T16:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENC2" b2="345 KV" b3="52-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="S1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TANNERSC" b2="345 KV" b3="TAN-LAW1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20900</SeqNum>
    <Name>L230.Nagel-CaneRiver</Name>
    <LastEdit Timestamp="2025-03-17T14:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CANERIV" b2="230 KV" b3="1NAG_BK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANERIV" b2="230 KV" b3="CRAG1NAG" />
      <ContingencyEquipment Action="L" Type="LN" b1="NAGELAEP" b2="230 KV" b3="NAG-CAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="230 KV" b3="S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20910</SeqNum>
    <Name>L230.EastDanville-YancyTp(CPL)-Concord4</Name>
    <LastEdit Timestamp="2026-03-20T10:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONCORD4" b2="230 KV" b3="1EDN_2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDANVILL" b2="230 KV" b3="EDA-YAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDANVILL" b2="230 KV" b3="S" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONCORD4" b2="230 KV" b3="31019A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="YANCYT" b2="230 KV" b3="94_TOPO1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20920</SeqNum>
    <Name>L230.EastDanville-Roxborough(CPL).S</Name>
    <LastEdit Timestamp="2025-06-05T08:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EDANVILL" b2="230 KV" b3="EDA-ROX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDANVILL" b2="230 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBOROG" b2="230 KV" b3="1EDNN_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBOROG" b2="230 KV" b3="1EDNN_UN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20930</SeqNum>
    <Name>L138.Kammer-WestBellaire</Name>
    <LastEdit Timestamp="2026-03-18T16:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="F CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="F1 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="KAMMER2" b2="138 KV" b3="KAM-WBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="138 KV" b3="C1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20940</SeqNum>
    <Name>L138.Brues-WestBellaire.2</Name>
    <LastEdit Timestamp="2026-03-18T16:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUES" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRUES" b2="138 KV" b3="BRU-WBE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="138 KV" b3="D2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20950</SeqNum>
    <Name>L138.Kammer-GeorgeWashington</Name>
    <LastEdit Timestamp="2025-01-06T16:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GEORGEWA" b2="138 KV" b3="GEO-KAM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20960</SeqNum>
    <Name>L138.Natrium-NauvooRidge</Name>
    <LastEdit Timestamp="2026-03-26T12:53:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAUVOORI" b2="138 KV" b3="H001S5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAUVOORI" b2="138 KV" b3="H001S8" />
      <ContingencyEquipment Action="L" Type="LN" b1="NATRIUM2" b2="138 KV" b3="NAT-NAUV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20970</SeqNum>
    <Name>L138.Kammer-Natrium</Name>
    <LastEdit Timestamp="2026-03-19T08:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KAMMER2" b2="138 KV" b3="KAM-NAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="K3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20980</SeqNum>
    <Name>L138.Tidd-Steubenville</Name>
    <LastEdit Timestamp="2024-10-23T13:22:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STEUBENV" b2="69 KV" b3="H018C8" />
      <ContingencyEquipment Action="X" Type="XF" b1="STEUBENV" b2="138 KV" b3="LOADXF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STEUBENV" b2="138 KV" b3="STE-TID1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>20990</SeqNum>
    <Name>L138.Sunnyside-WarnerSS-Torrey</Name>
    <LastEdit Timestamp="2026-03-19T08:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNNYSOP" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="WARNERSS" b2="138 KV" b3="SUN-WAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORREY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="WARNERSS" b2="138 KV" b3="TOR-WAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WARNERSS" b2="138 KV" b3="ALLOYS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21000</SeqNum>
    <Name>L138.Sunnyside-Wagenhals</Name>
    <LastEdit Timestamp="2026-03-19T08:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNNYSOP" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUNNYSOP" b2="138 KV" b3="SUN-WAG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="A CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21010</SeqNum>
    <Name>L138.CantonCentral-Wagenhal.2</Name>
    <LastEdit Timestamp="2024-09-19T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANTONCE" b2="138 KV" b3="CAN-WAG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21020</SeqNum>
    <Name>L138.CantonCentral-Wagenhal.1</Name>
    <LastEdit Timestamp="2024-09-19T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANTONCE" b2="138 KV" b3="CAN-WAG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21030</SeqNum>
    <Name>L138.SouthEastCanton-CantonCentral</Name>
    <LastEdit Timestamp="2026-03-19T09:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANTONCE" b2="138 KV" b3="CAN-SEC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="138 KV" b3="D2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21040</SeqNum>
    <Name>L138.TimkenRichville-SouthCanton</Name>
    <LastEdit Timestamp="2024-06-17T18:57:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STIMKEN" b2="138 KV" b3="H001J5" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCANTON2" b2="138 KV" b3="SCA-STI1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21050</SeqNum>
    <Name>L138.Timken-TimkenRichville</Name>
    <LastEdit Timestamp="2026-05-08T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STIMKEN" b2="138 KV" b3="H001H8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMKEN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="STIMKEN" b2="138 KV" b3="STI-TIM1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIMKEN" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21060</SeqNum>
    <Name>L138.SouthCanton-Torrey</Name>
    <LastEdit Timestamp="2026-03-19T09:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="L1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCANTON2" b2="138 KV" b3="SCA-TOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORREY" b2="138 KV" b3="Y" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21070</SeqNum>
    <Name>L138.SouthCanton-WestCanton</Name>
    <LastEdit Timestamp="2026-03-19T09:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="J2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCANTON2" b2="138 KV" b3="SCA-WCA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21080</SeqNum>
    <Name>L138.SCanton-AppleCrk-CanalRd-EWooster</Name>
    <LastEdit Timestamp="2025-03-18T11:56:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="APPLECRE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEALLAVE" b2="69 KV" b3="BEA-WOOS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEALLAVE" b2="69 KV" b3="T12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEALLAVE" b2="69 KV" b3="T3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEALLAVE" b2="69 KV" b3="BEA-CANR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANALROA" b2="138 KV" b3="CAN-APP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANALROA" b2="138 KV" b3="CAN-EWO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANALROA" b2="69 KV" b3="CAN-EWOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANALROA" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANALROA" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CANALROA" b2="34.5 KV" b3="LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CANALROA" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CANALROA" b2="69 KV" b3="LOAD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CANALROA" b2="138 KV" b3="T1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="CANALROA" b2="69 KV" b3="T1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="CANALROA" b2="34.5 KV" b3="T1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWOOSTER" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="K2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCANTON2" b2="138 KV" b3="SCA-APP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOOSTER" b2="69 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21090</SeqNum>
    <Name>L138.SouthCanton-Bolivar-CityOfDover</Name>
    <LastEdit Timestamp="2026-04-01T13:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOLIVAR" b2="138 KV" b3="BOL-COD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOLIVAR" b2="138 KV" b3="BOL-SCA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOLIVAR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CODOVER" b2="138 KV" b3="H002D8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="N2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21100</SeqNum>
    <Name>L138.WestNewPhiladelphia-CityOfDover</Name>
    <LastEdit Timestamp="2026-04-01T13:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CODOVER" b2="138 KV" b3="H002Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WNEWPHIL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CODOVER" b2="138 KV" b3="COD-WNE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WNEWPHIL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WNEWPHIL" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21110</SeqNum>
    <Name>L138.Wagenhals-NorthEastCanton</Name>
    <LastEdit Timestamp="2025-04-21T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NECANTON" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NECANTON" b2="138 KV" b3="J2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NECANTON" b2="138 KV" b3="NEC-WAG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="R" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21120</SeqNum>
    <Name>L138.SCanton-Negley-Reedurban</Name>
    <LastEdit Timestamp="2025-12-16T16:31:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEGLEY" b2="138 KV" b3="T1 LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEDURBA" b2="138 KV" b3="H007C8" />
      <ContingencyEquipment Action="L" Type="LN" b1="REEDURBA" b2="138 KV" b3="REE-NEG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="J1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEGLEY" b2="138 KV" b3="NEG-SCA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21130</SeqNum>
    <Name>L138.Wagenhal-BeldenVillage-Wayview</Name>
    <LastEdit Timestamp="2026-03-19T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELDENVI" b2="138 KV" b3="BEL-WAG" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELDENVI" b2="138 KV" b3="BEL-WAY1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELDENVI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELDENVI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYVIEW" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21140</SeqNum>
    <Name>L138.NewarkCenter-Ridgely-Kirk+138/69.NewarkCE.TR1</Name>
    <LastEdit Timestamp="2025-10-15T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="138 KV" b3="L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARKCE" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARKCE" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARKCE" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWARKCE" b2="138 KV" b3="NEW-RIDG" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWARKCE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KIRK" b2="138 KV" b3="KIR-RIDG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21150</SeqNum>
    <Name>L138.Conesville-NewarkCenter</Name>
    <LastEdit Timestamp="2026-03-19T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="138 KV" b3="4C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="138 KV" b3="4S" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONESVIL" b2="138 KV" b3="CON-NEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARKCE" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21160</SeqNum>
    <Name>L138.Conesville-Centerburg</Name>
    <LastEdit Timestamp="2025-11-25T16:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTERBU" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTERBU" b2="138 KV" b3="CEN-CON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="138 KV" b3="H013W2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="138 KV" b3="H013W5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21170</SeqNum>
    <Name>L138.OhioCentral-WTrinway-Millwood-Academia</Name>
    <LastEdit Timestamp="2025-10-02T10:58:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ACADEMIA" b2="138 KV" b3="ACA-MIL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ACADEMIA" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLWOO2" b2="138 KV" b3="MIL-WTR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILLWOO2" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="OHIOCENT" b2="138 KV" b3="OHI-WTR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WTRINWAY" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21180</SeqNum>
    <Name>L138.Culbertson-EastZanesville-Philo</Name>
    <LastEdit Timestamp="2025-06-27T09:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CULBERTS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CULBERTS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CULBERTS" b2="138 KV" b3="CUL-EZAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EZANESVI" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EZANESVI" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EZANESVI" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="X" Type="XF" b1="EZANESVI" b2="138 KV" b3="T-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="EZANESVI" b2="138 KV" b3="T-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHILO" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="EZANESVI" b2="138 KV" b3="EZA-PHI1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21190</SeqNum>
    <Name>L138.Powelson-NorthZanesville</Name>
    <LastEdit Timestamp="2026-03-19T09:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NZANESVI" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="NZANESVI" b2="138 KV" b3="NZA-POW1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NZANESVI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POWELSON" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POWELSON" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21200</SeqNum>
    <Name>L138.OhioCentral-SouthCoshocton</Name>
    <LastEdit Timestamp="2025-02-28T12:21:00" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="OHIOCENT" b2="138 KV" b3="OHI-SCO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOSHOCT" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21210</SeqNum>
    <Name>L138.OhioCentral-WstCoshocton-SMillers-WstMillburg</Name>
    <LastEdit Timestamp="2025-03-05T16:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKHRN" b2="138 KV" b3="BUC-HWB1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKHRN" b2="138 KV" b3="BUC-WCO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HWBUCKHO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="OHIOCENT" b2="138 KV" b3="OHI-WCO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SMILLERS" b2="138 KV" b3="SMI-BUC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SMILLERS" b2="138 KV" b3="SMI-WMI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SMILLERS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WCOSHOCT" b2="138 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCOSHOCT" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILBURG" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21220</SeqNum>
    <Name>L138.Clouse-JunctionCity-WestLancaster</Name>
    <LastEdit Timestamp="2026-04-30T13:18:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUSE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUSE" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOUSE" b2="138 KV" b3="CLO-JNC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JNCTCITY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLANCAST" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WLANCAST" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WLANCAST" b2="138 KV" b3="V" />
      <ContingencyEquipment Action="L" Type="LN" b1="WLANCAST" b2="138 KV" b3="WLA-JCT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21230</SeqNum>
    <Name>L138.Philo-WPhilo-NPhilo-Zanesville</Name>
    <LastEdit Timestamp="2026-03-19T09:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="NPHILOSW" b2="138 KV" b3="NPH-ZAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHILO" b2="138 KV" b3="HA" />
      <ContingencyEquipment Action="L" Type="LN" b1="PHILO" b2="138 KV" b3="PHI-WPH" />
      <ContingencyEquipment Action="L" Type="LN" b1="NPHILOSW" b2="138 KV" b3="NPH-WPH1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WPHILO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZANESVIL" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21240</SeqNum>
    <Name>L138.Maliszewski-Polaris</Name>
    <LastEdit Timestamp="2024-12-09T14:02:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MALISZEW" b2="138 KV" b3="MAL-POL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MALISZEW" b2="138 KV" b3="P1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MALISZEW" b2="138 KV" b3="P2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MALISZEW" b2="138 KV" b3="T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POLARIS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POLARIS" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POLARIS" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21250</SeqNum>
    <Name>L138.Maliszewski-Genoa</Name>
    <LastEdit Timestamp="2026-03-19T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GENOA" b2="138 KV" b3="103N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MALISZEW" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MALISZEW" b2="138 KV" b3="M2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MALISZEW" b2="138 KV" b3="MAL-GEN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21260</SeqNum>
    <Name>L138.Maliszewski-HyattCS.1</Name>
    <LastEdit Timestamp="2026-03-19T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="105C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="105N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MALISZEW" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MALISZEW" b2="138 KV" b3="M1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MALISZEW" b2="138 KV" b3="MAL-HYA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21270</SeqNum>
    <Name>L138.Maliszewski-HyattCS.2</Name>
    <LastEdit Timestamp="2026-03-19T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="104C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="104N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MALISZEW" b2="138 KV" b3="L1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MALISZEW" b2="138 KV" b3="M2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MALISZEW" b2="138 KV" b3="MAL-HYA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MALISZEW" b2="138 KV" b3="P2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21280</SeqNum>
    <Name>L138.Delaware-Hyattcs</Name>
    <LastEdit Timestamp="2026-05-08T14:51:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELAWARE" b2="138 KV" b3="114" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="103C" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELAWARE" b2="138 KV" b3="DEL-HYA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="H010S2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21290</SeqNum>
    <Name>L138.HyattCS-Sawmill.1</Name>
    <LastEdit Timestamp="2026-03-19T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="104C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="104S" />
      <ContingencyEquipment Action="L" Type="LN" b1="HYATTCS" b2="138 KV" b3="HYA-SAW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="105C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="105N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21300</SeqNum>
    <Name>L138.Sawmill-Brookside</Name>
    <LastEdit Timestamp="2025-05-19T15:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSDE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKSDE" b2="138 KV" b3="BRO-SAW1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BROOKSDE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="105C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="105S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21310</SeqNum>
    <Name>L138.Corridor-Morse</Name>
    <LastEdit Timestamp="2025-04-14T10:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="104C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="104N" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORRIDOR" b2="138 KV" b3="COR-MOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="K" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21320</SeqNum>
    <Name>L138.Corridor-Gahanna</Name>
    <LastEdit Timestamp="2026-03-19T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="105C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="105N" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORRIDOR" b2="138 KV" b3="COR-GAH1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="111" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21330</SeqNum>
    <Name>L138.Stelzer-Morse</Name>
    <LastEdit Timestamp="2025-01-31T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORSE" b2="138 KV" b3="MOR-STE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STELZER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STELZER" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21340</SeqNum>
    <Name>L138.Roberts-Bethel</Name>
    <LastEdit Timestamp="2024-10-25T13:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHEL2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHEL2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHEL2" b2="138 KV" b3="BET-ROB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="H1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21350</SeqNum>
    <Name>L138.Roberts-Kenny</Name>
    <LastEdit Timestamp="2026-05-06T10:53:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNY" b2="138 KV" b3="106" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KENNY" b2="138 KV" b3="MOBILE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="J1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENNY" b2="138 KV" b3="KEN-ROB1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21360</SeqNum>
    <Name>L138.Roberts-WilsonCS</Name>
    <LastEdit Timestamp="2026-03-20T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROBERTS2" b2="138 KV" b3="ROB-WIL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONCS" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONCS" b2="138 KV" b3="5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21370</SeqNum>
    <Name>L138.Clinton-Kenny</Name>
    <LastEdit Timestamp="2025-03-28T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTOCS" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTOCS" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNY" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNY" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINTOCS" b2="138 KV" b3="CLI-KEN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KENNY" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21390</SeqNum>
    <Name>L138.WilsonCS-Beatty</Name>
    <LastEdit Timestamp="2026-03-20T10:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="2C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="2W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONCS" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONCS" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEATTY" b2="138 KV" b3="BEA-WIL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21410</SeqNum>
    <Name>L138.Hocking-Kimberly-Lemaster</Name>
    <LastEdit Timestamp="2024-11-21T14:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOCKING" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOCKING" b2="138 KV" b3="HOC-KIM" />
      <ContingencyEquipment Action="L" Type="LN" b1="KIMBERLY" b2="138 KV" b3="KIM-LEM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KIMBERLY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KIMBERLY" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMASTER" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMASTER" b2="138 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21420</SeqNum>
    <Name>L138.WestLancaster-SouthLancaster</Name>
    <LastEdit Timestamp="2026-03-20T10:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SLANCAST" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SLANCAST" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLANCAST" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="SLANCAST" b2="138 KV" b3="SLA-WLA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21430</SeqNum>
    <Name>L138.Beatty-WhiteRoad</Name>
    <LastEdit Timestamp="2024-05-13T11:27:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="2C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="2E" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEATTY" b2="138 KV" b3="BEA-WHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITERD" b2="138 KV" b3="A_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITERD" b2="138 KV" b3="H001C5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21440</SeqNum>
    <Name>L138.Beatty-McComb</Name>
    <LastEdit Timestamp="2025-12-15T15:39:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="1E" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEATTY" b2="138 KV" b3="BEA-MCC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCOMB" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MCCOMB" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCOMB" b2="138 KV" b3="H024D8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCCOMB" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21460</SeqNum>
    <Name>L138.Canal-Mound</Name>
    <LastEdit Timestamp="2025-11-18T10:27:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CANALAEP" b2="138 KV" b3="CAN-MOU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANALAEP" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANALAEP" b2="138 KV" b3="H006Q8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANALAEP" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUND" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUND" b2="138 KV" b3="104" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21480</SeqNum>
    <Name>L138.Leon-Sporn</Name>
    <LastEdit Timestamp="2024-12-24T13:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEONAP" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEONAP" b2="138 KV" b3="LEO-SPO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="JJ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="JJ1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21500</SeqNum>
    <Name>L138.Canal-Bixby</Name>
    <LastEdit Timestamp="2025-02-18T12:31:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="138 KV" b3="114" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="138 KV" b3="115" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIXBY" b2="138 KV" b3="BIX-CANA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANALAEP" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANALAEP" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21520</SeqNum>
    <Name>L138.NorthProctorville-Bellefonte</Name>
    <LastEdit Timestamp="2025-11-17T11:51:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEFON" b2="138 KV" b3="X" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLEFON" b2="138 KV" b3="BEL-NPR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="138 KV" b3="E1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21530</SeqNum>
    <Name>L138.NorthProctorville-SouthPoint</Name>
    <LastEdit Timestamp="2026-03-20T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NPROCTO2" b2="138 KV" b3="NPR-SPO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOINT" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21560</SeqNum>
    <Name>L138.SouthPoint-Kenova-Tristate + 138/69.Kenova.T8</Name>
    <LastEdit Timestamp="2026-05-18T15:09:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="KENOVA" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENOVA" b2="69 KV" b3="A014X5" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENOVA" b2="138 KV" b3="KEN-SPO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENOVA" b2="138 KV" b3="KEN-TRI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KENOVA" b2="138 KV" b3="T7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOINT" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="F1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21570</SeqNum>
    <Name>L138.SouthPoint-Millbrook</Name>
    <LastEdit Timestamp="2026-03-20T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLBROO" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLBROO" b2="138 KV" b3="MIL-SPO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOINT" b2="138 KV" b3="V" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21580</SeqNum>
    <Name>L138.Darrah-Tristate</Name>
    <LastEdit Timestamp="2026-03-20T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARRAH" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARRAH" b2="138 KV" b3="DAR-TRI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21590</SeqNum>
    <Name>L138.Gavin-Sporn</Name>
    <LastEdit Timestamp="2026-03-24T08:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="138 KV" b3="AD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="138 KV" b3="AD2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPORNAEP" b2="138 KV" b3="SPO-GAV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="J2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21600</SeqNum>
    <Name>L138.Gavin-FireBrick</Name>
    <LastEdit Timestamp="2026-03-20T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FIREBRIK" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="138 KV" b3="AE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="138 KV" b3="AE2 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIREBRIK" b2="138 KV" b3="FIR-GAV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21610</SeqNum>
    <Name>L138.NPortsmouth-Millbrook</Name>
    <LastEdit Timestamp="2025-04-08T10:18:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MILLBROO" b2="138 KV" b3="MIL-NPO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLBROO" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPORTSMO" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21620</SeqNum>
    <Name>L138.Sporn-Constellium.1</Name>
    <LastEdit Timestamp="2026-02-10T09:41:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONSTELM" b2="138 KV" b3="1_3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONSTELM" b2="138 KV" b3="A110" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONSTELM" b2="138 KV" b3="CON-SPO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="A2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21640</SeqNum>
    <Name>L138.Sporn-Constellium.2</Name>
    <LastEdit Timestamp="2026-02-10T09:41:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONSTELM" b2="138 KV" b3="2_4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONSTELM" b2="138 KV" b3="A330" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONSTELM" b2="138 KV" b3="CON-SPO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="GG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="GG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21660</SeqNum>
    <Name>L138.Sporn-Mountaineer.1</Name>
    <LastEdit Timestamp="2026-03-20T10:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUNTAIN" b2="138 KV" b3="701" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUNTAIN" b2="138 KV" b3="MOU-SPO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="P2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21670</SeqNum>
    <Name>L138.Sporn-Mountaineer.2</Name>
    <LastEdit Timestamp="2026-03-24T08:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUNTAIN" b2="138 KV" b3="601" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MOUNTAIN" b2="138 KV" b3="TCH2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUNTAIN" b2="138 KV" b3="MOU-SPO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="O" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="O1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21680</SeqNum>
    <Name>L138.Sporn-AmericanAlloy</Name>
    <LastEdit Timestamp="2026-03-20T10:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMALLOY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMALLOY" b2="138 KV" b3="AMA-SPO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="G2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21690</SeqNum>
    <Name>L138.AppleGrove-Mercerville-Thivener-Sporn</Name>
    <LastEdit Timestamp="2026-03-24T08:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="APPLEGRO" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="L" Type="LN" b1="APPLEGRO" b2="138 KV" b3="APP-MER1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MERCERBU" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="L2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPORNAEP" b2="138 KV" b3="SPO-THI" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERCERBU" b2="138 KV" b3="MER-THI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="THIVENER" b2="138 KV" b3="SPOI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21700</SeqNum>
    <Name>L138.TannersCreek-Wesley-CollegeCorner</Name>
    <LastEdit Timestamp="2026-03-20T10:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLLEGEC" b2="138 KV" b3="COL-WES1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLEGEC" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLEGEC" b2="138 KV" b3="K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="TANNERSC" b2="138 KV" b3="TAN-WES" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESLEY" b2="138 KV" b3="WESLEYLD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21710</SeqNum>
    <Name>L138.Madison-Shankatank</Name>
    <LastEdit Timestamp="2025-10-30T15:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON" b2="138 KV" b3="U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHANKATK" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHANKATK" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="MADISON" b2="138 KV" b3="MAD-SHAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21720</SeqNum>
    <Name>L138.TannersCreek-Pendleton</Name>
    <LastEdit Timestamp="2026-03-20T10:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENDLETO" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENDLETO" b2="138 KV" b3="PEN-TAN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21730</SeqNum>
    <Name>L138.Madison-CrossTap-Hogan</Name>
    <LastEdit Timestamp="2025-07-15T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CROSSSTR" b2="138 KV" b3="CRO-CRO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CROSSSTR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROSSTAP" b2="138 KV" b3="CRO-HOG1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROSSTAP" b2="138 KV" b3="CRO-MAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOGAN" b2="138 KV" b3="AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOGAN" b2="138 KV" b3="AB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON" b2="138 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21740</SeqNum>
    <Name>L138.Madison-Daleville-Medford</Name>
    <LastEdit Timestamp="2025-04-18T17:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DALEVILL" b2="138 KV" b3="DAL-MAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DALEVILL" b2="138 KV" b3="DAL-MED1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DALEVILL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEDFORD" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEDFORD" b2="138 KV" b3="D2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21750</SeqNum>
    <Name>L138.Madison-FallCreek</Name>
    <LastEdit Timestamp="2025-01-16T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLCREE" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLCREE" b2="138 KV" b3="G2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FALLCREE" b2="138 KV" b3="FAL-MAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21760</SeqNum>
    <Name>L138.Madison-Delcoremy</Name>
    <LastEdit Timestamp="2026-03-20T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELCORM5" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DELCORM5" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELCORM5" b2="138 KV" b3="DEL-MAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON" b2="138 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21770</SeqNum>
    <Name>765/138.JoshuaFalls.1</Name>
    <LastEdit Timestamp="2025-08-04T13:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="JOSHUAF2" b2="765 KV" b3=".  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOSHUAF2" b2="765 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOSHUAF2" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOSHUAF2" b2="138 KV" b3="H1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21780</SeqNum>
    <Name>765/345.Cloverdale.T17</Name>
    <LastEdit Timestamp="2025-04-10T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="765 KV" b3="DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="765 KV" b3="DD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVERD2" b2="765 KV" b3="T17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="345 KV" b3="U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="345 KV" b3="U2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21800</SeqNum>
    <Name>765/138.JacksonsFerry.T2</Name>
    <LastEdit Timestamp="2024-10-18T13:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="JACKSONS" b2="765 KV" b3=".  2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="765 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="P1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21820</SeqNum>
    <Name>765/345.Baker.T100</Name>
    <LastEdit Timestamp="2026-03-23T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BAKER" b2="765 KV" b3=".100" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="345 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="345 KV" b3="H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="765 KV" b3="P2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="765 KV" b3="Q2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21830</SeqNum>
    <Name>765/345.Sullivan.T1</Name>
    <LastEdit Timestamp="2026-03-23T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="345 KV" b3="D2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SULLIVA2" b2="765 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21840</SeqNum>
    <Name>765/345.Sullivan.T2</Name>
    <LastEdit Timestamp="2026-03-23T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="765 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="345 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="345 KV" b3="H2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SULLIVA2" b2="765 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21860</SeqNum>
    <Name>765/345.Cook.T4</Name>
    <LastEdit Timestamp="2026-03-23T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="COOK" b2="765 KV" b3="4-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="COOK" b2="345 KV" b3="4-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="COOK" b2="34 KV" b3="4-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="765 KV" b3="A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COOK" b2="34 KV" b3="AUX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="34 KV" b3="BC" />
      <ContingencyEquipment Action="CL" Type="CB" b1="COOK" b2="34 KV" b3="BD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="K1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21880</SeqNum>
    <Name>765/345.Dumont.T2</Name>
    <LastEdit Timestamp="2025-06-27T09:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="765 KV" b3="A2_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="765 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="345 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="345 KV" b3="H2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DUMONT2" b2="765 KV" b3="RXFG" />
      <ContingencyEquipment Action="X" Type="XF" b1="DUMONT2" b2="765 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21890</SeqNum>
    <Name>765/345.Kammer.T400</Name>
    <LastEdit Timestamp="2025-10-07T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="KAMMER2" b2="765 KV" b3="400" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="345 KV" b3="CC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="345 KV" b3="CC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="765 KV" b3="MM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="765 KV" b3="MMA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21910</SeqNum>
    <Name>765/230/138.Greentown.T2</Name>
    <LastEdit Timestamp="2025-12-05T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="GREENTO2" b2="765 KV" b3="2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENTO2" b2="230 KV" b3="2-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENTO2" b2="138 KV" b3="2-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="230 KV" b3="21B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="230 KV" b3="22B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="765 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="765 KV" b3="M2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21920</SeqNum>
    <Name>345/138.Cloverdale.T19</Name>
    <LastEdit Timestamp="2024-06-11T15:01:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVERD2" b2="345 KV" b3="T19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="345 KV" b3="U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="345 KV" b3="U1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21930</SeqNum>
    <Name>L138.Baker-BigSandy + 345/138.Baker.T200</Name>
    <LastEdit Timestamp="2026-01-06T11:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BAKER" b2="345 KV" b3="200" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="345 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="345 KV" b3="J1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAKER" b2="138 KV" b3="BAK-BIG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="D2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21940</SeqNum>
    <Name>345/138.Beatty.4</Name>
    <LastEdit Timestamp="2024-05-29T10:11:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="345 KV" b3="302E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="345 KV" b3="304E" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEATTY" b2="345 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="L1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21950</SeqNum>
    <Name>345/138.Beatty.3</Name>
    <LastEdit Timestamp="2024-05-29T10:11:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BEATTY" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="345 KV" b3="302W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="345 KV" b3="304W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="5C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="5E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21960</SeqNum>
    <Name>765/345/34.Amos.T5</Name>
    <LastEdit Timestamp="2026-03-23T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="AMOS" b2="765 KV" b3="5-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="AMOS" b2="345 KV" b3="5-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="AMOS" b2="34 KV" b3="5-T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMOS" b2="34 KV" b3="CENTSW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="345 KV" b3="K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="P" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMOS" b2="34 KV" b3="SS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21970</SeqNum>
    <Name>345/138.Hyattcs.T1A&amp;B</Name>
    <LastEdit Timestamp="2025-10-23T12:10:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="101C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="H006R2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="M1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="M2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HYATTCS" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>21980</SeqNum>
    <Name>345/138.Sorenson.T2</Name>
    <LastEdit Timestamp="2026-03-20T10:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SORENSON" b2="345 KV" b3="2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SORENSON" b2="138 KV" b3="2-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="N2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22000</SeqNum>
    <Name>345/138.SouthWestLima.T2</Name>
    <LastEdit Timestamp="2024-12-03T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SWLIMA" b2="345 KV" b3=".  2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="138 KV" b3="L2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22010</SeqNum>
    <Name>345/138.SouthWestLima.T1</Name>
    <LastEdit Timestamp="2026-03-20T10:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SWLIMA" b2="345 KV" b3=".  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="138 KV" b3="K1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22020</SeqNum>
    <Name>345/138/34.Amos.T8</Name>
    <LastEdit Timestamp="2026-03-23T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="AMOS" b2="345 KV" b3="8-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="AMOS" b2="138 KV" b3="8-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="AMOS" b2="34 KV" b3="8-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="345 KV" b3="J2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="345 KV" b3="K2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMOS" b2="34 KV" b3="PRECIP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMOS" b2="34 KV" b3="T8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22030</SeqNum>
    <Name>345/138/34.Amos.T7</Name>
    <LastEdit Timestamp="2026-03-23T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="AMOS" b2="345 KV" b3="7-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="AMOS" b2="138 KV" b3="7-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="AMOS" b2="34 KV" b3="7-T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMOS" b2="34 KV" b3="COAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="345 KV" b3="J1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="345 KV" b3="K1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMOS" b2="34 KV" b3="LOADSS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMOS" b2="34 KV" b3="T7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22040</SeqNum>
    <Name>L138.SouthCaldwell-SouthOliveSW-Macksburg</Name>
    <LastEdit Timestamp="2024-11-13T13:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MACKSBRG" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCALDWEL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCALDWEL" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCALDWEL" b2="138 KV" b3="SCA-SOL" />
      <ContingencyEquipment Action="L" Type="LN" b1="MACKSBRG" b2="138 KV" b3="MAC-SOL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOLIVESW" b2="138 KV" b3="SOLIVE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22060</SeqNum>
    <Name>345/138.CLoverdale.T3</Name>
    <LastEdit Timestamp="2024-11-13T09:40:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVERD2" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="345 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="345 KV" b3="R1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22070</SeqNum>
    <Name>500/138.Nagel.T3</Name>
    <LastEdit Timestamp="2025-01-30T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NAGELAEP" b2="500 KV" b3=".  3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="500 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="500 KV" b3="J2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="138 KV" b3="L2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22080</SeqNum>
    <Name>L345.Greene-SugarCreek</Name>
    <LastEdit Timestamp="2025-03-28T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="345 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="345 KV" b3="BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENE" b2="345 KV" b3="GRE-SUG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="345 KV" b3="RS-DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="345 KV" b3="RS-FF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22090</SeqNum>
    <Name>L345.Bath-Greene</Name>
    <LastEdit Timestamp="2025-05-08T12:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="345 KV" b3="GL-EE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="345 KV" b3="GL-FF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="345 KV" b3="EE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="345 KV" b3="FF" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENE" b2="345 KV" b3="GRE-BAT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22100</SeqNum>
    <Name>L345.Bath-Miami</Name>
    <LastEdit Timestamp="2025-05-08T12:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BATH" b2="345 KV" b3="BAT-MIA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="345 KV" b3="GL-HH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="345 KV" b3="GL-JJ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="345 KV" b3="GG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="345 KV" b3="HH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22110</SeqNum>
    <Name>L345.Miami-Shelby</Name>
    <LastEdit Timestamp="2026-03-23T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="345 KV" b3="EE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="345 KV" b3="GG" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHELBY" b2="345 KV" b3="SHE-MIA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="345 KV" b3="DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="345 KV" b3="FF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22130</SeqNum>
    <Name>L345.Miami-WestMilton</Name>
    <LastEdit Timestamp="2025-08-01T15:02:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="345 KV" b3="DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="345 KV" b3="EE" />
      <ContingencyEquipment Action="L" Type="LN" b1="WMILTON" b2="345 KV" b3="WMI-MIA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="345 KV" b3="OC-AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="345 KV" b3="OC-BB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22140</SeqNum>
    <Name>L345.Chenoweth-Madison</Name>
    <LastEdit Timestamp="2024-05-21T14:07:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHENOWET" b2="345 KV" b3="H005V5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHENOWET" b2="345 KV" b3="H005V8" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHENOWET" b2="345 KV" b3="CHE-MADI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON2" b2="345 KV" b3="JM-BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON2" b2="345 KV" b3="JM-EE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22150</SeqNum>
    <Name>L345.Adkins-Atlanta</Name>
    <LastEdit Timestamp="2026-01-09T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADKINS" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADKINS" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATLNTA" b2="345 KV" b3="ATL-ADK1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ATLNTA" b2="345 KV" b3="BK-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLNTA" b2="69 KV" b3="JA-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLNTA" b2="69 KV" b3="JA-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLNTA" b2="345 KV" b3="JA-BB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22160</SeqNum>
    <Name>L345.Foster-SugarCreek</Name>
    <LastEdit Timestamp="2025-03-28T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="345 KV" b3="1355" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="345 KV" b3="1357" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTER2" b2="345 KV" b3="FOS-SUG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="345 KV" b3="RS-BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="345 KV" b3="RS-EE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22170</SeqNum>
    <Name>L345.Clinton-Greene</Name>
    <LastEdit Timestamp="2025-12-05T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON3" b2="345 KV" b3="EE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON3" b2="345 KV" b3="HE-FF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="345 KV" b3="CC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="345 KV" b3="FF" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENE" b2="345 KV" b3="GRE-CLI1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22180</SeqNum>
    <Name>L345.Atlanta-Stuart</Name>
    <LastEdit Timestamp="2025-10-14T18:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLNTA" b2="345 KV" b3="JA-BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="STUART2" b2="345 KV" b3="STU-ATL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUART2" b2="345 KV" b3="SS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUART2" b2="345 KV" b3="TT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22210</SeqNum>
    <Name>345/138.Greene.BK-N</Name>
    <LastEdit Timestamp="2026-03-20T10:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="345 KV" b3="AA" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENE" b2="345 KV" b3="BK-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="345 KV" b3="DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="I" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22220</SeqNum>
    <Name>345/138.Greene.BK-S</Name>
    <LastEdit Timestamp="2026-03-20T10:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="GREENE" b2="138 KV" b3="138C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="345 KV" b3="BB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENE" b2="345 KV" b3="BK-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="345 KV" b3="CC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22230</SeqNum>
    <Name>345/138.Bath.BK-S</Name>
    <LastEdit Timestamp="2025-05-12T14:23:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BATH" b2="345 KV" b3="BK-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="138 KV" b3="GL-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="345 KV" b3="GL-FF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="138 KV" b3="GL-G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="345 KV" b3="GL-JJ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22240</SeqNum>
    <Name>345/138.Miami.BK-E</Name>
    <LastEdit Timestamp="2026-03-23T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="MIAMI" b2="138 KV" b3="138C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MIAMI" b2="138 KV" b3="138R" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIAMI" b2="345 KV" b3="BK-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="345 KV" b3="DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="345 KV" b3="HH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="138 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22250</SeqNum>
    <Name>345/138.Shelby.BK-N</Name>
    <LastEdit Timestamp="2026-03-20T10:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SHELBY" b2="345 KV" b3="BK-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="138 KV" b3="BLN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="345 KV" b3="FF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="345 KV" b3="JJ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22260</SeqNum>
    <Name>L345.Clinton-Clay</Name>
    <LastEdit Timestamp="2025-11-14T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAY" b2="345 KV" b3="HA-AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAY" b2="345 KV" b3="HA-BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAY" b2="345 KV" b3="CLA-CLIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON3" b2="345 KV" b3="HE-AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON3" b2="345 KV" b3="HE-CC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22270</SeqNum>
    <Name>Amos.U1</Name>
    <LastEdit Timestamp="2026-03-23T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="AMOS" b2="26 KV" b3="AM1" />
      <ContingencyEquipment Action="X" Type="XF" b1="AMOS" b2="765 KV" b3="GSU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="S1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22280</SeqNum>
    <Name>Amos.U2</Name>
    <LastEdit Timestamp="2026-03-23T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="AMOS" b2="26 KV" b3="AM2" />
      <ContingencyEquipment Action="X" Type="XF" b1="AMOS" b2="345 KV" b3="GSU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="345 KV" b3="K1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22290</SeqNum>
    <Name>Amos.U3</Name>
    <LastEdit Timestamp="2026-03-23T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="AMOS" b2="26 KV" b3="AM3" />
      <ContingencyEquipment Action="X" Type="XF" b1="AMOS" b2="765 KV" b3="GSU3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22300</SeqNum>
    <Name>Mountaineer.U1</Name>
    <LastEdit Timestamp="2025-09-08T09:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUNTAIN" b2="765 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUNTAIN" b2="765 KV" b3="C1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOUNTAIN" b2="765 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOUNTAIN" b2="26 KV" b3="MT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22360</SeqNum>
    <Name>ClinchRiver.U1</Name>
    <LastEdit Timestamp="2026-03-23T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLINCHRI" b2="15.5 KV" b3="CR1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLINCHRI" b2="138 KV" b3="GSU1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22370</SeqNum>
    <Name>ClinchRiver.U2</Name>
    <LastEdit Timestamp="2026-03-23T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLINCHRI" b2="15.5 KV" b3="CR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLINCHRI" b2="138 KV" b3="GSU2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22390</SeqNum>
    <Name>SmithMountain.U1&amp;U5</Name>
    <LastEdit Timestamp="2026-03-23T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMITHMOU" b2="138 KV" b3="GSU1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMITHMOU" b2="138 KV" b3="GSU5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SMITHMOU" b2="13.8 KV" b3="SM1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SMITHMOU" b2="13.8 KV" b3="SM5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22400</SeqNum>
    <Name>SmithMountain.U2</Name>
    <LastEdit Timestamp="2026-03-23T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="2G" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMITHMOU" b2="138 KV" b3="GSU2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SMITHMOU" b2="13.8 KV" b3="SM2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22410</SeqNum>
    <Name>SmithMountain.U3</Name>
    <LastEdit Timestamp="2026-03-23T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="3G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="3P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMITHMOU" b2="138 KV" b3="GSU3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SMITHMOU" b2="13.8 KV" b3="SM3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22420</SeqNum>
    <Name>SmithMountain.U4</Name>
    <LastEdit Timestamp="2026-03-23T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="4G" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMITHMOU" b2="138 KV" b3="GSU4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SMITHMOU" b2="13.8 KV" b3="SM4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22480</SeqNum>
    <Name>Gavin.U1</Name>
    <LastEdit Timestamp="2026-03-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="765 KV" b3="B2" />
      <ContingencyEquipment Action="X" Type="XF" b1="GAVINAEP" b2="765 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GAVINAEP" b2="26 KV" b3="GV1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22490</SeqNum>
    <Name>Gavin.U2</Name>
    <LastEdit Timestamp="2026-03-23T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="765 KV" b3="A2" />
      <ContingencyEquipment Action="X" Type="XF" b1="GAVINAEP" b2="765 KV" b3="GSU2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GAVINAEP" b2="26 KV" b3="GV2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22500</SeqNum>
    <Name>Kammer.Mitchell.U1 (765kV)</Name>
    <LastEdit Timestamp="2026-03-23T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="KAMMER2" b2="765 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KAMMER2" b2="26 KV" b3="ML1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="765 KV" b3="PP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="765 KV" b3="PP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22510</SeqNum>
    <Name>Kammer.Mitchell.U2 (345kV)</Name>
    <LastEdit Timestamp="2026-03-23T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="345 KV" b3="CC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="345 KV" b3="CC2" />
      <ContingencyEquipment Action="X" Type="XF" b1="KAMMER2" b2="345 KV" b3="GSU2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KAMMER2" b2="26 KV" b3="ML2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22550</SeqNum>
    <Name>BigSandy.U1</Name>
    <LastEdit Timestamp="2026-03-23T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BIGSANDY" b2="138 KV" b3="1E" />
      <ContingencyEquipment Action="X" Type="XF" b1="BIGSANDY" b2="138 KV" b3="1W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BIGSANDY" b2="22 KV" b3="BS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22570</SeqNum>
    <Name>Flatlick.U1&amp;2&amp;3</Name>
    <LastEdit Timestamp="2026-03-23T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="FLATLICK" b2="18 KV" b3="1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FLATLICK" b2="18 KV" b3="2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FLATLICK" b2="18 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLATLICK" b2="765 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLATLICK" b2="765 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22580</SeqNum>
    <Name>Flatlick.U4&amp;5</Name>
    <LastEdit Timestamp="2026-03-23T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="FLATLICK" b2="18 KV" b3="4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FLATLICK" b2="18 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLATLICK" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLATLICK" b2="765 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22590</SeqNum>
    <Name>Tidd.Cardinal.U2</Name>
    <LastEdit Timestamp="2026-03-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="BB1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TIDD_AEP" b2="24 KV" b3="CD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22600</SeqNum>
    <Name>Tidd.Cardinal.U1</Name>
    <LastEdit Timestamp="2026-03-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="TIDD_AEP" b2="24 KV" b3="CD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="K1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22610</SeqNum>
    <Name>Tidd.Cardinal.U3</Name>
    <LastEdit Timestamp="2026-03-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="TIDD_AEP" b2="26 KV" b3="CD3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="FF1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="FF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22720</SeqNum>
    <Name>Cook.U2</Name>
    <LastEdit Timestamp="2024-10-16T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="765 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="765 KV" b3="A2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COOK" b2="26 KV" b3="CK2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22730</SeqNum>
    <Name>Cook.U1</Name>
    <LastEdit Timestamp="2024-10-16T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="COOK" b2="26 KV" b3="CK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="O" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="O1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22760</SeqNum>
    <Name>Racine.U1</Name>
    <LastEdit Timestamp="2026-03-24T08:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RACINE" b2="8 KV" b3="1B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RACINE" b2="8 KV" b3="RA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22770</SeqNum>
    <Name>Racine.U2</Name>
    <LastEdit Timestamp="2026-03-24T08:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RACINE" b2="8 KV" b3="1A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RACINE" b2="8 KV" b3="RA2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22780</SeqNum>
    <Name>Rockport.U1</Name>
    <LastEdit Timestamp="2025-02-13T14:15:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPOR2" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPOR2" b2="765 KV" b3="A1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROCKPOR2" b2="26 KV" b3="RP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22790</SeqNum>
    <Name>Rockport.U2</Name>
    <LastEdit Timestamp="2026-03-24T08:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPOR2" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPOR2" b2="765 KV" b3="B1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROCKPOR2" b2="26 KV" b3="RP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22800</SeqNum>
    <Name>L345.Ramsey-Holland (Ameren)</Name>
    <LastEdit Timestamp="2024-11-18T13:02:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HDNW" b2="345 KV" b3="3516" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HDNW" b2="345 KV" b3="3519" />
      <ContingencyEquipment Action="L" Type="LN" b1="HDNW" b2="345 KV" b3="HDN-RAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMSEY 3" b2="345 KV" b3="V23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMSEY 3" b2="345 KV" b3="V25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22810</SeqNum>
    <Name>L69.Jenkins-Owens-EMountain-BearCrk-Palooka.2</Name>
    <LastEdit Timestamp="2025-08-06T14:36:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BEAR CRK" b2="69 KV" b3="TAP2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAR CRK" b2="69 KV" b3="BEA-EAS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTMNTN" b2="69 KV" b3="EAS-OWE2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTMNTN" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="JENKINS" b2="69 KV" b3="JEN-OWE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="PALO2_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="PALO2_S" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OWENSILL" b2="69 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OWENSILL" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAR CRK" b2="69 KV" b3="BEA-PAL2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PALOOKA" b2="69 KV" b3="DUM6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PALOOKA" b2="69 KV" b3="GEOR_LD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22820</SeqNum>
    <Name>Zelda.U1+U2+U3</Name>
    <LastEdit Timestamp="2026-03-26T08:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ZELDA" b2="345 KV" b3="1_DF5B55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZELDA" b2="345 KV" b3="2_623E57" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZELDA" b2="345 KV" b3="3_5E90BD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ZELDA" b2="18 KV" b3="UNIT 1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ZELDA" b2="18 KV" b3="UNIT 2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ZELDA" b2="18 KV" b3="UNIT 3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22830</SeqNum>
    <Name>Tait.CT1</Name>
    <LastEdit Timestamp="2026-03-24T08:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="TAITCT" b2="13.8 KV" b3="09T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAITCT" b2="69 KV" b3="19" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAITCT" b2="69 KV" b3="GSU1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22840</SeqNum>
    <Name>Tait.CT2</Name>
    <LastEdit Timestamp="2026-03-24T08:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="TAITCT" b2="13.8 KV" b3="09T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAITCT" b2="69 KV" b3="11" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAITCT" b2="69 KV" b3="GSU2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22850</SeqNum>
    <Name>Yankee.U1</Name>
    <LastEdit Timestamp="2026-03-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="09YANKEE" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="X" Type="XF" b1="09YANKEE" b2="69 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="09YANKEE" b2="12.5 KV" b3="UN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22860</SeqNum>
    <Name>Yankee.U2</Name>
    <LastEdit Timestamp="2026-03-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="09YANKEE" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="X" Type="XF" b1="09YANKEE" b2="69 KV" b3="GSU2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="09YANKEE" b2="12.5 KV" b3="UN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22870</SeqNum>
    <Name>Yankee.U3</Name>
    <LastEdit Timestamp="2026-03-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="09YANKEE" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="X" Type="XF" b1="09YANKEE" b2="69 KV" b3="GSU3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="09YANKEE" b2="12.5 KV" b3="UN3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22880</SeqNum>
    <Name>Yankee.U4</Name>
    <LastEdit Timestamp="2026-03-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="09YANKEE" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="X" Type="XF" b1="09YANKEE" b2="69 KV" b3="GSU4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="09YANKEE" b2="13.2 KV" b3="UN4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22890</SeqNum>
    <Name>Yankee.U5</Name>
    <LastEdit Timestamp="2026-03-25T16:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="09YANKEE" b2="69 KV" b3="GSU5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="09YANKEE" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="U" Type="GEN" b1="09YANKEE" b2="13.2 KV" b3="UN5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22900</SeqNum>
    <Name>Yankee.U6</Name>
    <LastEdit Timestamp="2026-03-25T16:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="09YANKEE" b2="69 KV" b3="GSU6" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="09YANKEE" b2="69 KV" b3="I" />
      <ContingencyEquipment Action="U" Type="GEN" b1="09YANKEE" b2="13.2 KV" b3="UN6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22910</SeqNum>
    <Name>Yankee.U7</Name>
    <LastEdit Timestamp="2026-03-25T16:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="09YANKEE" b2="69 KV" b3="GSU7" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="09YANKEE" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="U" Type="GEN" b1="09YANKEE" b2="13.2 KV" b3="UN7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>22980</SeqNum>
    <Name>Hutchings.U7</Name>
    <LastEdit Timestamp="2026-03-24T08:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HUTCHING" b2="69 KV" b3="GSU7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUTCHING" b2="13.8 KV" b3="HU7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="69 KV" b3="HU7_5123" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23040</SeqNum>
    <Name>Greenville.GT1</Name>
    <LastEdit Timestamp="2026-03-23T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09GRNVIL" b2="69 KV" b3="G1CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="09GRNVIL" b2="69 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="09GRNVIL" b2="13.8 KV" b3="GT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23050</SeqNum>
    <Name>Greenville.GT2</Name>
    <LastEdit Timestamp="2026-03-24T08:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09GRNVIL" b2="69 KV" b3="G2CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="09GRNVIL" b2="69 KV" b3="GSU2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="09GRNVIL" b2="13.8 KV" b3="GT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23060</SeqNum>
    <Name>Greenville.GT3</Name>
    <LastEdit Timestamp="2026-03-24T08:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09GRNVIL" b2="69 KV" b3="G3CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="09GRNVIL" b2="69 KV" b3="GSU3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="09GRNVIL" b2="13.8 KV" b3="GT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23070</SeqNum>
    <Name>Greenville.GT4</Name>
    <LastEdit Timestamp="2026-03-24T08:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09GRNVIL" b2="69 KV" b3="G4CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="09GRNVIL" b2="69 KV" b3="GSU4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="09GRNVIL" b2="13.8 KV" b3="GT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23080</SeqNum>
    <Name>Tait.U3</Name>
    <LastEdit Timestamp="2026-03-24T08:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="TAITCT" b2="13.8 KV" b3="09T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAITCT" b2="69 KV" b3="14" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAITCT" b2="69 KV" b3="GSU3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23090</SeqNum>
    <Name>Tait.U5</Name>
    <LastEdit Timestamp="2026-03-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="TAITCT" b2="13.8 KV" b3="09T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAITCT" b2="69 KV" b3="32" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAITCT" b2="69 KV" b3="GSU5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23100</SeqNum>
    <Name>Tait.U7</Name>
    <LastEdit Timestamp="2026-03-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="TAITCT" b2="13.8 KV" b3="09T7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAITCT" b2="69 KV" b3="34" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAITCT" b2="69 KV" b3="GSU7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23110</SeqNum>
    <Name>Sidney.Diesel</Name>
    <LastEdit Timestamp="2026-03-23T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="09SIDNEY" b2="69 KV" b3="DIESEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09SIDNEY" b2="69 KV" b3="DIESELCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23120</SeqNum>
    <Name>Monument.Diesel</Name>
    <LastEdit Timestamp="2026-03-23T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="09MONUMT" b2="12 KV" b3="DIESEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09MONUMT" b2="12 KV" b3="DIESELCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23130</SeqNum>
    <Name>Tait.Diesel</Name>
    <LastEdit Timestamp="2026-03-24T08:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TAIT" b2="12.5 KV" b3="BHD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TAIT" b2="4 KV" b3="DIESEL" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAIT" b2="12.5 KV" b3="GSUD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23160</SeqNum>
    <Name>Tait.U4</Name>
    <LastEdit Timestamp="2026-03-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="TAITCT" b2="13.8 KV" b3="09T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAITCT" b2="69 KV" b3="29" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAITCT" b2="69 KV" b3="GSU4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23170</SeqNum>
    <Name>Tait.U6</Name>
    <LastEdit Timestamp="2026-03-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="TAITCT" b2="13.8 KV" b3="09T6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAITCT" b2="69 KV" b3="33" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAITCT" b2="69 KV" b3="GSU6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23180</SeqNum>
    <Name>Adkins.GT1</Name>
    <LastEdit Timestamp="2026-03-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADKINS" b2="345 KV" b3="G1CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ADKINS" b2="13.8 KV" b3="GT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23190</SeqNum>
    <Name>Adkins.GT2</Name>
    <LastEdit Timestamp="2026-03-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADKINS" b2="345 KV" b3="G2CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ADKINS" b2="13.8 KV" b3="GT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23200</SeqNum>
    <Name>Adkins.GT3</Name>
    <LastEdit Timestamp="2026-03-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADKINS" b2="345 KV" b3="G3CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ADKINS" b2="13.8 KV" b3="GT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23210</SeqNum>
    <Name>Adkins.GT4</Name>
    <LastEdit Timestamp="2026-03-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADKINS" b2="345 KV" b3="G4CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ADKINS" b2="13.8 KV" b3="GT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23220</SeqNum>
    <Name>Adkins.GT5</Name>
    <LastEdit Timestamp="2026-03-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADKINS" b2="345 KV" b3="G5CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ADKINS" b2="13.8 KV" b3="GT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23230</SeqNum>
    <Name>Adkins.GT6</Name>
    <LastEdit Timestamp="2026-03-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADKINS" b2="345 KV" b3="G6CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ADKINS" b2="13.8 KV" b3="GT6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23240</SeqNum>
    <Name>20 Braidwood.U1</Name>
    <LastEdit Timestamp="2024-10-16T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="20 BRAID" b2="24 KV" b3="BR-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="20 BRAID" b2="345 KV" b3="TR1E 24" />
      <ContingencyEquipment Action="X" Type="XF" b1="20 BRAID" b2="345 KV" b3="TR1W 24" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23250</SeqNum>
    <Name>20 Braidwood.U2</Name>
    <LastEdit Timestamp="2024-10-16T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="20 BRAID" b2="24 KV" b3="BR-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT9-10CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23260</SeqNum>
    <Name>6 Byron.U1</Name>
    <LastEdit Timestamp="2024-10-16T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="6 BYRON" b2="25 KV" b3="BY-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23270</SeqNum>
    <Name>6 Byron.U2</Name>
    <LastEdit Timestamp="2024-10-16T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="6 BYRON" b2="25 KV" b3="BY-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23310</SeqNum>
    <Name>(NUKE) 12Dresden.U2</Name>
    <LastEdit Timestamp="2024-10-10T13:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT1-7 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="12 DRESD" b2="18 KV" b3="DR-2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="12 DRESD" b2="345 KV" b3="DUMBED1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="12 DRESD" b2="345 KV" b3="DUMBED2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="12 DRESD" b2="345 KV" b3="DUMBED3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="12 DRESD" b2="345 KV" b3="DUMBED4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="12 DRESD" b2="345 KV" b3="DUMBED5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="12 DRESD" b2="345 KV" b3="DUMBED6" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="12 DRESD" b2="345 KV" b3="DUMBED7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23320</SeqNum>
    <Name>(NUKE) 12Dresden.U3</Name>
    <LastEdit Timestamp="2025-05-05T12:34:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="12 DRESD" b2="18 KV" b3="DR-3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="12 DRESD" b2="345 KV" b3="DUMBED10" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="12 DRESD" b2="345 KV" b3="DUMBED11" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="12 DRESD" b2="345 KV" b3="DUMBED14" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="12 DRESD" b2="345 KV" b3="DUMBED15" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="12 DRESD" b2="345 KV" b3="DUMBED8" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="12 DRESD" b2="345 KV" b3="DUMBED9" />
      <ContingencyEquipment Action="X" Type="XF" b1="12 DRESD" b2="345 KV" b3="TR3 18" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23370</SeqNum>
    <Name>21 Kincaid.U1</Name>
    <LastEdit Timestamp="2026-03-25T16:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="21 KINCA" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="21 KINCA" b2="345 KV" b3="BT2-6 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="21 KINCA" b2="20 KV" b3="KN-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23380</SeqNum>
    <Name>21 Kincaid.U2</Name>
    <LastEdit Timestamp="2026-03-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="21 KINCA" b2="345 KV" b3="BT6-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="21 KINCA" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="21 KINCA" b2="20 KV" b3="KN-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23390</SeqNum>
    <Name>1 Lasalle.U1</Name>
    <LastEdit Timestamp="2024-10-16T12:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="1 LASALL" b2="24 KV" b3="LA-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="1 LASALL" b2="345 KV" b3="TR1E 24" />
      <ContingencyEquipment Action="X" Type="XF" b1="1 LASALL" b2="345 KV" b3="TR1W 24" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23400</SeqNum>
    <Name>1 Lasalle.U2</Name>
    <LastEdit Timestamp="2024-10-16T12:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="1 LASALL" b2="24 KV" b3="LA-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="1 LASALL" b2="345 KV" b3="TR2E 24" />
      <ContingencyEquipment Action="X" Type="XF" b1="1 LASALL" b2="345 KV" b3="TR2W 24" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23410</SeqNum>
    <Name>3 Powerton.U5</Name>
    <LastEdit Timestamp="2026-02-10T09:12:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="3 POWERT" b2="24 KV" b3="PO-5" />
      <ContingencyEquipment Action="X" Type="XF" b1="3 POWERT" b2="345 KV" b3="TR5 24" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="3 POWERT" b2="24 KV" b3="TR54104" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="3 POWERT" b2="24 KV" b3="TR54204" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23420</SeqNum>
    <Name>3 Powerton.U6</Name>
    <LastEdit Timestamp="2026-02-10T09:13:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="3 POWERT" b2="24 KV" b3="PO-6" />
      <ContingencyEquipment Action="X" Type="XF" b1="3 POWERT" b2="345 KV" b3="TR6 24" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="3 POWERT" b2="24 KV" b3="TR64104" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="3 POWERT" b2="24 KV" b3="TR64204" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23430</SeqNum>
    <Name>(NUKE) 4 Quad Cities.U1</Name>
    <LastEdit Timestamp="2025-08-01T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED10" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED11" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED6" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED7" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED8" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED9" />
      <ContingencyEquipment Action="U" Type="GEN" b1="4 QUAD C" b2="18 KV" b3="QC-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="4 QUAD C" b2="345 KV" b3="TR1 18" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23440</SeqNum>
    <Name>(NUKE) 4 Quad Cities.U2</Name>
    <LastEdit Timestamp="2024-10-10T13:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT1-11CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED10" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED11" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED6" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED7" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED8" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="4 QUAD C" b2="345 KV" b3="DUMBED9" />
      <ContingencyEquipment Action="U" Type="GEN" b1="4 QUAD C" b2="18 KV" b3="QC-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23470</SeqNum>
    <Name>16 Waukegan.U31 &amp; U32</Name>
    <LastEdit Timestamp="2026-03-25T16:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="138 KV" b3="TR16 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="16 WAUKE" b2="138 KV" b3="WA31" />
      <ContingencyEquipment Action="S" Type="SD" b1="16 WAUKE" b2="138 KV" b3="WA31_2Z1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="16 WAUKE" b2="138 KV" b3="WA32" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23540</SeqNum>
    <Name>L138.OhioCentral-Wakatomica-NBellville</Name>
    <LastEdit Timestamp="2026-05-08T14:55:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NBELLVIL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="NBELLVIL" b2="138 KV" b3="NBE-WAKA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="L" Type="LN" b1="OHIOCENT" b2="138 KV" b3="OHI-WAKA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAKATOMI" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23560</SeqNum>
    <Name>L765.Collins - Plano.2315</Name>
    <LastEdit Timestamp="2026-03-25T16:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="23 COLLI" b2="765 KV" b3="2315" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="765 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="765 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="23 COLLI" b2="765 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="23 COLLI" b2="765 KV" b3="BT3-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23570</SeqNum>
    <Name>L765.Wilton-Collins.11216</Name>
    <LastEdit Timestamp="2025-11-10T09:18:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="23 COLLI" b2="765 KV" b3="11216" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="765 KV" b3="BT1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="765 KV" b3="BT1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="23 COLLI" b2="765 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="23 COLLI" b2="765 KV" b3="BT4-5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23580</SeqNum>
    <Name>L345.Lasalle - Plano.0101</Name>
    <LastEdit Timestamp="2026-03-25T16:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="1 LASALL" b2="345 KV" b3="0101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="345 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="345 KV" b3="BT10-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="345 KV" b3="BT8-9 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23590</SeqNum>
    <Name>L345.Lasalle - Plano.0102</Name>
    <LastEdit Timestamp="2026-03-25T16:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="1 LASALL" b2="345 KV" b3="0102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="345 KV" b3="BT3-5CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23600</SeqNum>
    <Name>L345.Lasalle - Braidwood.0103</Name>
    <LastEdit Timestamp="2026-03-25T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="1 LASALL" b2="345 KV" b3="0103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT4-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT9-15CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23610</SeqNum>
    <Name>L345.Lasalle - Braidwood.0104</Name>
    <LastEdit Timestamp="2026-03-25T16:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="1 LASALL" b2="345 KV" b3="0104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT1113CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT1-8 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23620</SeqNum>
    <Name>L345.Powerton-KatydidRd.0301</Name>
    <LastEdit Timestamp="2026-03-25T16:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="196 KATY" b2="345 KV" b3="BT4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="196 KATY" b2="345 KV" b3="BT5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="196 KATY" b2="345 KV" b3="0301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT1-6 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23660</SeqNum>
    <Name>L345.Powerton-MoleCreek.0302</Name>
    <LastEdit Timestamp="2025-11-21T12:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="3 POWERT" b2="345 KV" b3="0302" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT4-9CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="908 MOLE" b2="345 KV" b3="BT1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="908 MOLE" b2="345 KV" b3="BT1-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23670</SeqNum>
    <Name>L138.Fisk-Y764-2.L1125 </Name>
    <LastEdit Timestamp="2025-06-17T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="1-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="11 FISK" b2="138 KV" b3="1125" />
      <ContingencyEquipment Action="OP" Type="CB" b1="Y764-2" b2="138 KV" b3="4-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23680</SeqNum>
    <Name>L138.Fisk-Y764-2.L1127 </Name>
    <LastEdit Timestamp="2025-06-17T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="10-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="11-12" />
      <ContingencyEquipment Action="L" Type="LN" b1="11 FISK" b2="138 KV" b3="1127" />
      <ContingencyEquipment Action="OP" Type="CB" b1="Y764-2" b2="138 KV" b3="2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23690</SeqNum>
    <Name>L138.WestNyack-SnakeHillRd.562 (NYISO)</Name>
    <LastEdit Timestamp="2024-10-03T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SNKEHLRD" b2="138 KV" b3="2-24-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SNKEHLRD" b2="138 KV" b3="3-24-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SNKEHLRD" b2="138 KV" b3="SNK-WNYA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WNYACK" b2="138 KV" b3="562-21-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23700</SeqNum>
    <Name>L345.Powerton-Dee Mac Rd.0303</Name>
    <LastEdit Timestamp="2026-05-19T12:58:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="915_DEEM" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="915_DEEM" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="915_DEEM" b2="345 KV" b3="DEE-POWE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23730</SeqNum>
    <Name>L345.HillTopper-MtPulaski.99401 + HillTopper.WF</Name>
    <LastEdit Timestamp="2024-10-25T13:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="188 MTPU" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="188 MTPU" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="188 MTPU" b2="345 KV" b3="99401" />
      <ContingencyEquipment Action="X" Type="XF" b1="994 HILL" b2="345 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="994 HILL" b2="34.5 KV" b3="HILLTPWF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="994 HILL" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23740</SeqNum>
    <Name>L345.Powerton-Tazewell.0304</Name>
    <LastEdit Timestamp="2024-07-16T14:35:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="3 POWERT" b2="345 KV" b3="0304" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT8-11CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWEL2" b2="345 KV" b3="V43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWEL2" b2="345 KV" b3="V45" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23760</SeqNum>
    <Name>L345.GunnRoad-Hardin</Name>
    <LastEdit Timestamp="2024-10-23T09:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GUNNROAD" b2="345 KV" b3="GUN-HAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUNNROAD" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUNNROAD" b2="345 KV" b3="N1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN" b2="345 KV" b3="D1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23770</SeqNum>
    <Name>L345.EastLima-Hardin</Name>
    <LastEdit Timestamp="2024-10-23T09:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="345 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="345 KV" b3="R1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN" b2="345 KV" b3="D1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMA" b2="345 KV" b3="ELI-HAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23780</SeqNum>
    <Name>L345.QuadCities-Sub91.0401</Name>
    <LastEdit Timestamp="2025-06-03T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="4 QUAD C" b2="345 KV" b3="0401 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT4-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUB 91" b2="161 KV" b3="OCB91824" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUB 91" b2="161 KV" b3="OCB91844" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUB 91" b2="345 KV" b3="PCB91944" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUB 91" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23790</SeqNum>
    <Name>L345.QuadCities-Cordova.0402</Name>
    <LastEdit Timestamp="2026-03-25T16:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="4 QUAD C" b2="345 KV" b3="0402" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="QC901CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="QC905CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23800</SeqNum>
    <Name>L345.940Cordova-Sub39 </Name>
    <LastEdit Timestamp="2025-06-26T11:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="940 CORD" b2="345 KV" b3="39-QC-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="QC901CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="QC902CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUB 39" b2="345 KV" b3="39914" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUB 39" b2="345 KV" b3="934" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23810</SeqNum>
    <Name>L345.QuadCities-Cordova.0403</Name>
    <LastEdit Timestamp="2026-03-25T16:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="4 QUAD C" b2="345 KV" b3="0403" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="BT1-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23840</SeqNum>
    <Name>L345.QuadCities-H471.0404</Name>
    <LastEdit Timestamp="2026-03-25T16:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="4 QUAD C" b2="345 KV" b3="0404" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT1-11CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H471" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H471" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="H471" b2="345 KV" b3="TR83 34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23870</SeqNum>
    <Name>L345.QuadCities-RockCreek.0405</Name>
    <LastEdit Timestamp="2026-03-25T16:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="4 QUAD C" b2="345 KV" b3="0405" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCK CRE" b2="345 KV" b3="180" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCK CRE" b2="345 KV" b3="182" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23890</SeqNum>
    <Name>L345.Byron-CherryValley.0621</Name>
    <LastEdit Timestamp="2026-03-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="6 BYRON" b2="345 KV" b3="0621" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="345 KV" b3="BT4-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="BT5-6 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23910</SeqNum>
    <Name>L345.Byron-CherryValley.0622</Name>
    <LastEdit Timestamp="2026-03-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="6 BYRON" b2="345 KV" b3="0622" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="345 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="BT1213CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23930</SeqNum>
    <Name>L345.Byron-Wempletown.0624</Name>
    <LastEdit Timestamp="2026-03-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="171 WEMP" b2="345 KV" b3="0624" />
      <ContingencyEquipment Action="OP" Type="CB" b1="171 WEMP" b2="345 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="171 WEMP" b2="345 KV" b3="BT2-11CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="10-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="BT1011CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23950</SeqNum>
    <Name>L345.Byron-LeeCounty.0627</Name>
    <LastEdit Timestamp="2026-03-26T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="6 BYRON" b2="345 KV" b3="0627" />
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="BT3-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="937 LEE" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="937 LEE" b2="345 KV" b3="BT2-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>23980</SeqNum>
    <Name>L345.Sheffield-7StateLine</Name>
    <LastEdit Timestamp="2025-06-03T11:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="345 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="7 STATE" b2="345 KV" b3="BT3-4 M" />
      <ContingencyEquipment Action="L" Type="LN" b1="7 STATE" b2="345 KV" b3="STA-SHE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="345 KV" b3="1112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="345 KV" b3="1120" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24000</SeqNum>
    <Name>L345.7StateLine-177Burnham.0722 </Name>
    <LastEdit Timestamp="2025-02-25T19:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="7 STATE" b2="345 KV" b3="0722" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT1213CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT2-13CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT8-13CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="345 KV" b3="BT2-4 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="7 STATE" b2="345 KV" b3="BT3-4 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24020</SeqNum>
    <Name>L345.12Dresden-900Elwood.1220</Name>
    <LastEdit Timestamp="2025-11-06T15:17:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="345 KV" b3="1220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="5-20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT8-12CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT9-10CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24030</SeqNum>
    <Name>L345.Dresden-WolfsCrossing.1221</Name>
    <LastEdit Timestamp="2026-04-02T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="345 KV" b3="1221" />
      <ContingencyEquipment Action="OP" Type="CB" b1="143 WOLF" b2="345 KV" b3="BT1-2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24040</SeqNum>
    <Name>L345.WolfsCrossing-ElectricJct.14321 + Wolfs.TR81</Name>
    <LastEdit Timestamp="2026-04-02T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="345 KV" b3="L14321CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="143 WOLF" b2="345 KV" b3="14321" />
      <ContingencyEquipment Action="OP" Type="CB" b1="143 WOLF" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="143 WOLF" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="143 WOLF" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="143 WOLF" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24050</SeqNum>
    <Name>L345.12 Dresden-900 Elwood.1222</Name>
    <LastEdit Timestamp="2025-01-20T10:06:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="11-12" />
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="345 KV" b3="1222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT2-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24060</SeqNum>
    <Name>L345.Dresden-ElectricJct.1223</Name>
    <LastEdit Timestamp="2026-04-02T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="345 KV" b3="1223" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="345 KV" b3="L1223 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="TR83" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24070</SeqNum>
    <Name>L345.Crawford-GoodingGrove.1311</Name>
    <LastEdit Timestamp="2026-04-02T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="13 CRAWF" b2="345 KV" b3="1311" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="L1311 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT7-8 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24090</SeqNum>
    <Name>L345.Crawford-GoodingsGrove.1312</Name>
    <LastEdit Timestamp="2026-04-02T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="L1312 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="13 CRAWF" b2="345 KV" b3="1312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT4-5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24100</SeqNum>
    <Name>L345.Braidwood-EastFrankfort.2001</Name>
    <LastEdit Timestamp="2026-04-02T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="20 BRAID" b2="345 KV" b3="2001" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="345 KV" b3="BT8-14CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="345 KV" b3="BT9-14CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24110</SeqNum>
    <Name>L345.Braidwood-DavisCreek.2002</Name>
    <LastEdit Timestamp="2024-11-05T14:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT4-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT7-11CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="86 DAVIS" b2="345 KV" b3="2002" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="345 KV" b3="6-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="345 KV" b3="9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24120</SeqNum>
    <Name>345/138.DavisCreek.TR83</Name>
    <LastEdit Timestamp="2024-10-31T08:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="345 KV" b3="4-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="86 DAVIS" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="86 DAVIS" b2="138 KV" b3="TR83CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24130</SeqNum>
    <Name>L345.Braidwood-EastFrankfort.2003</Name>
    <LastEdit Timestamp="2026-03-26T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="20 BRAID" b2="345 KV" b3="2003" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT1415CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT9-15CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="345 KV" b3="BT1-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="345 KV" b3="BT6-7 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24140</SeqNum>
    <Name>L345.Braidwood-Davis.2004</Name>
    <LastEdit Timestamp="2025-10-16T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="86 DAVIS" b2="345 KV" b3="2004" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT1114CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT7-11CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="20 BRAID" b2="345 KV" b3="DUMSD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="345 KV" b3="2-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="345 KV" b3="BT1-2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24150</SeqNum>
    <Name>L138.Sporn-YellowBush-KeraLakes</Name>
    <LastEdit Timestamp="2024-12-12T13:21:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KERALAKE" b2="138 KV" b3="A008D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERALAKE" b2="138 KV" b3="A008E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KERALAKE" b2="138 KV" b3="KER-YELL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPORNAEP" b2="138 KV" b3="SPO-YELL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="YELLOWBU" b2="138 KV" b3="GATLINGC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24160</SeqNum>
    <Name>L345.BlueMnd-TwinGrove.98901 + HighTrail.WF</Name>
    <LastEdit Timestamp="2026-02-11T10:21:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="178 BLUE" b2="345 KV" b3="98901" />
      <ContingencyEquipment Action="OP" Type="CB" b1="178 BLUE" b2="345 KV" b3="BT1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="178 BLUE" b2="345 KV" b3="BT2-3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="989 TWIN" b2="34.5 KV" b3="CAPC1-1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="989 TWIN" b2="34.5 KV" b3="CAPC1-2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="989 TWIN" b2="34.5 KV" b3="CAPC1-3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="989 TWIN" b2="34.5 KV" b3="CAPC1-4" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="989 TWIN" b2="34.5 KV" b3="CAPC1-5" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="989 TWIN" b2="34.5 KV" b3="CAPC1-6" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="989 TWIN" b2="34.5 KV" b3="CAPC2-1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="989 TWIN" b2="34.5 KV" b3="CAPC2-2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="989 TWIN" b2="34.5 KV" b3="CAPC2-3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="989 TWIN" b2="34.5 KV" b3="CAPC2-4" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="989 TWIN" b2="34.5 KV" b3="CAPC2-5" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="989 TWIN" b2="34.5 KV" b3="CAPC2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="989 TWIN" b2="34.5 KV" b3="GEN1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="989 TWIN" b2="34.5 KV" b3="GEN2CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="989 TWIN" b2="345 KV" b3="GSU1" />
      <ContingencyEquipment Action="X" Type="XF" b1="989 TWIN" b2="345 KV" b3="GSU2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="989 TWIN" b2="34.5 KV" b3="HTRAILWF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="989 TWIN" b2="34.5 KV" b3="OTRAILWF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24170</SeqNum>
    <Name>L345.Pontiac-BlueMound.8002</Name>
    <LastEdit Timestamp="2026-04-02T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="80 PONTI" b2="345 KV" b3="8002" />
      <ContingencyEquipment Action="OP" Type="CB" b1="178 BLUE" b2="345 KV" b3="BT1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="178 BLUE" b2="345 KV" b3="BT2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="80 PONTI" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="80 PONTI" b2="345 KV" b3="BT5-6 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24190</SeqNum>
    <Name>L345.Kincaid-Lanesville.2101</Name>
    <LastEdit Timestamp="2026-03-26T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LANESVL" b2="345 KV" b3="2101 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="21 KINCA" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="21 KINCA" b2="345 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANESVL" b2="345 KV" b3="BT3586CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANESVL" b2="345 KV" b3="BT3587CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24250</SeqNum>
    <Name>L345.Kincaid-Latham.2102</Name>
    <LastEdit Timestamp="2026-03-26T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="21 KINCA" b2="345 KV" b3="BT3-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="21 KINCA" b2="345 KV" b3="BT5-7 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="21 KINCA" b2="345 KV" b3="2102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LATHAM" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LATHAM" b2="345 KV" b3="V15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24300</SeqNum>
    <Name>L345.Kincaid-Pana.2105</Name>
    <LastEdit Timestamp="2026-02-10T09:13:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="21 KINCA" b2="345 KV" b3="BT2-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="21 KINCA" b2="345 KV" b3="BT6-8 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="PANA" b2="345 KV" b3="PAN-21K" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="21 KINCA" b2="345 KV" b3="TR24304" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANA" b2="345 KV" b3="V51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANA" b2="345 KV" b3="V53" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24380</SeqNum>
    <Name>L345.Waukegan-Northbrook.1626</Name>
    <LastEdit Timestamp="2024-12-17T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="159 NORT" b2="345 KV" b3="1626" />
      <ContingencyEquipment Action="OP" Type="CB" b1="159 NORT" b2="345 KV" b3="L1626" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="345 KV" b3="BT9-11CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24410</SeqNum>
    <Name>L345.Waukegan-Zion.2219</Name>
    <LastEdit Timestamp="2026-03-26T10:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="345 KV" b3="BT4-5CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="345 KV" b3="BT4-6CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="16 WAUKE" b2="345 KV" b3="L2219" />
      <ContingencyEquipment Action="OP" Type="CB" b1="22 ZION" b2="345 KV" b3="BT1718CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="22 ZION" b2="345 KV" b3="BT2-17CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24420</SeqNum>
    <Name>L345.Zion-PleasantPrairie.2221</Name>
    <LastEdit Timestamp="2026-05-08T13:22:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="22 ZION" b2="345 KV" b3="2-3LINK" />
      <ContingencyEquipment Action="L" Type="LN" b1="22 ZION" b2="345 KV" b3="2221" />
      <ContingencyEquipment Action="OP" Type="CB" b1="22 ZION" b2="345 KV" b3="BT2-17CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEAS PR" b2="345 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEAS PR" b2="345 KV" b3="6-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24430</SeqNum>
    <Name>L345.22_Zion-Paris.2222</Name>
    <LastEdit Timestamp="2026-05-08T13:24:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="22 ZION" b2="345 KV" b3="7-20LINK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="22 ZION" b2="345 KV" b3="BT1920CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="PARIS 83" b2="345 KV" b3="PAR-ZION" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARIS 83" b2="345 KV" b3="9304" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARIS 83" b2="345 KV" b3="9305" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24440</SeqNum>
    <Name>L345.22_Zion-974_Zion.2223</Name>
    <LastEdit Timestamp="2026-05-08T13:25:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="22 ZION" b2="345 KV" b3="2223" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="22 ZION" b2="345 KV" b3="4-5LINK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="22 ZION" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="974 ZION" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="974 ZION" b2="345 KV" b3="BT1-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24450</SeqNum>
    <Name>L345.154Libertyville-22Zion.2224</Name>
    <LastEdit Timestamp="2026-05-08T13:26:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="22 ZION" b2="345 KV" b3="2224" />
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="22 ZION" b2="345 KV" b3="18-19LNK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="22 ZION" b2="345 KV" b3="BT1920CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24460</SeqNum>
    <Name>L345.Collins-Kendall.2310</Name>
    <LastEdit Timestamp="2026-04-02T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="23 COLLI" b2="345 KV" b3="2310" />
      <ContingencyEquipment Action="OP" Type="CB" b1="23 COLLI" b2="345 KV" b3="L2310 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="BT1-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="BT2-5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24470</SeqNum>
    <Name>L345.23 Collins-12 Dresden.2311</Name>
    <LastEdit Timestamp="2024-11-13T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="345 KV" b3="2311" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="L2311" />
      <ContingencyEquipment Action="OP" Type="CB" b1="23 COLLI" b2="345 KV" b3="BT1-2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24480</SeqNum>
    <Name>L345.Joliet-Lockport.2912</Name>
    <LastEdit Timestamp="2026-04-02T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="29 JOLIE" b2="345 KV" b3="2912" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="29 JOLIE" b2="345 KV" b3="L2912 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24490</SeqNum>
    <Name>L345.Joliet-Lockport.2913</Name>
    <LastEdit Timestamp="2026-04-02T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="29 JOLIE" b2="345 KV" b3="2913" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT3-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="29 JOLIE" b2="345 KV" b3="L2913 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24500</SeqNum>
    <Name>L345.Desplains-ProspectHeights.4620</Name>
    <LastEdit Timestamp="2026-03-26T10:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="46 DESPL" b2="345 KV" b3="4620" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="345 KV" b3="L4620 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24510</SeqNum>
    <Name>L345.Desplains-GolfMill.4621 + GolfMill.TR82</Name>
    <LastEdit Timestamp="2024-12-02T14:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="172 GOLF" b2="345 KV" b3="4621" />
      <ContingencyEquipment Action="L" Type="LN" b1="88 SKOKI" b2="345 KV" b3="8823" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="172 GOLF" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="172 GOLF" b2="138 KV" b3="TR82CT-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="345 KV" b3="L4621 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24520</SeqNum>
    <Name>L345.Desplains-GolfMill.4622 + GolfMill.TR81</Name>
    <LastEdit Timestamp="2024-12-02T14:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="172 GOLF" b2="345 KV" b3="4622" />
      <ContingencyEquipment Action="L" Type="LN" b1="88 SKOKI" b2="345 KV" b3="8824" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="172 GOLF" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="172 GOLF" b2="138 KV" b3="TR81CT-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="345 KV" b3="L4622 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24530</SeqNum>
    <Name>L345.EFrankfort-Crete.6607</Name>
    <LastEdit Timestamp="2025-04-29T17:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="66 E FRN" b2="345 KV" b3="6607" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="345 KV" b3="BT9-14CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="945 CRET" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="945 CRET" b2="345 KV" b3="BT2-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24540</SeqNum>
    <Name>345L6608 E Frankfort-UP North 345 kV Line</Name>
    <LastEdit Timestamp="2025-08-22T10:04:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="66 E FRN" b2="345 KV" b3="6608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="345 KV" b3="BT1-4ACB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="345 KV" b3="BT4A-6CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="970 UP N" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="970 UP N" b2="345 KV" b3="BT1-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24550</SeqNum>
    <Name>L345.Loretto-Cayuga.97601 + CayugaRidgeSouth.WF</Name>
    <LastEdit Timestamp="2024-05-15T09:44:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="93 LORET" b2="345 KV" b3="97601" />
      <ContingencyEquipment Action="OP" Type="CB" b1="93 LORET" b2="345 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="93 LORET" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="976 CAYU" b2="34.5 KV" b3="CAYUG1WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="976 CAYU" b2="34.5 KV" b3="CAYUG2WF" />
      <ContingencyEquipment Action="X" Type="XF" b1="976 CAYU" b2="345 KV" b3="TR1" />
      <ContingencyEquipment Action="X" Type="XF" b1="976 CAYU" b2="345 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="976 CAYU" b2="345 KV" b3="TRCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24560</SeqNum>
    <Name>L345.Dresden-Pontiac.8014</Name>
    <LastEdit Timestamp="2024-05-15T09:56:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="14-15" />
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="345 KV" b3="8014" />
      <ContingencyEquipment Action="OP" Type="CB" b1="80 PONTI" b2="345 KV" b3="6-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="80 PONTI" b2="345 KV" b3="BT7-8 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24580</SeqNum>
    <Name>L345.GolfMill-Skokie.8823 R</Name>
    <LastEdit Timestamp="2025-04-28T15:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="88 SKOKI" b2="345 KV" b3="8823" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="88 SKOKI" b2="345 KV" b3="L8823 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24590</SeqNum>
    <Name>L345.Skokie-GolfMill.8824 R</Name>
    <LastEdit Timestamp="2025-04-28T15:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="88 SKOKI" b2="345 KV" b3="8824" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="88 SKOKI" b2="345 KV" b3="L8824 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24600</SeqNum>
    <Name>L345.Itasca-Desplains.10111 + 345/138.TR84 RF</Name>
    <LastEdit Timestamp="2026-01-21T15:15:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="46 DESPL" b2="345 KV" b3="10111 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="345 KV" b3="18-19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="345 KV" b3="19-20" />
      <ContingencyEquipment Action="S" Type="SD" b1="46 DESPL" b2="345 KV" b3="10111 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="345 KV" b3="L10111CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="345 KV" b3="T84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="46 DESPL" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="46 DESPL" b2="138 KV" b3="TR84CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="46 DESPL" b2="34.5 KV" b3="TR84CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24610</SeqNum>
    <Name>L345.Itasca-Desplains.10112 R</Name>
    <LastEdit Timestamp="2024-11-05T16:40:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="46 DESPL" b2="345 KV" b3="10112 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="345 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="46 DESPL" b2="345 KV" b3="1234 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24670</SeqNum>
    <Name>L138.187 SchauffRoad-980 Walnut.98001 + Walnut.WF</Name>
    <LastEdit Timestamp="2025-12-26T12:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="187 SCHA" b2="138 KV" b3="4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="187 SCHA" b2="138 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="187 SCHA" b2="138 KV" b3="98001" />
      <ContingencyEquipment Action="OP" Type="CB" b1="980 WALN" b2="138 KV" b3="CB01" />
      <ContingencyEquipment Action="OP" Type="CB" b1="980 WALN" b2="138 KV" b3="CB02" />
      <ContingencyEquipment Action="U" Type="GEN" b1="980 WALN" b2="34.5 KV" b3="WALNT2WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="980 WALN" b2="34.5 KV" b3="WALNTRWF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24700</SeqNum>
    <Name>L345.Lockport-Kendall.10805</Name>
    <LastEdit Timestamp="2024-10-18T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="108 LOCK" b2="345 KV" b3="10805" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="BT6-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="BT6-9 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24710</SeqNum>
    <Name>L345.DeerCreek-Beason.98704</Name>
    <LastEdit Timestamp="2025-05-28T10:28:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="909DCREE" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="909DCREE" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="987_BEAS" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="987_BEAS" b2="345 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="987_BEAS" b2="345 KV" b3="BEA-DCRE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24720</SeqNum>
    <Name>L345.108Lockport-935Kendall.10806</Name>
    <LastEdit Timestamp="2024-12-10T16:00:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="108 LOCK" b2="345 KV" b3="10806" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="BT2-5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24740</SeqNum>
    <Name>L345.Itasca-Lockport.10808-2</Name>
    <LastEdit Timestamp="2026-05-08T14:21:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="345 KV" b3="17-22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="345 KV" b3="21-22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT7-12CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="101 ITAS" b2="345 KV" b3="ITA-LOCK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24750</SeqNum>
    <Name>L345.ElectricJct-Aurora.11119</Name>
    <LastEdit Timestamp="2026-04-02T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="111 ELEC" b2="345 KV" b3="11119" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="345 KV" b3="L11119CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="345 KV" b3="BT2-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24760</SeqNum>
    <Name>L345.111ElectricJct-11120-W407-120Lombard.11120</Name>
    <LastEdit Timestamp="2025-03-24T16:02:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="111 ELEC" b2="345 KV" b3="11120 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="345 KV" b3="L11120CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="11120" b2="345 KV" b3="11120 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="11120" b2="345 KV" b3="11120 4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="11120" b2="345 KV" b3="2001 S" />
      <ContingencyEquipment Action="L" Type="LN" b1="120 LOMB" b2="345 KV" b3="11120 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="345 KV" b3="L11120CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="14419" b2="345 KV" b3="1901 S" />
      <ContingencyEquipment Action="L" Type="LN" b1="14419" b2="345 KV" b3="14419 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W407-4" b2="345 KV" b3="L11120CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="W407-4" b2="345 KV" b3="TR82 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="W407-4" b2="345 KV" b3="TR83 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="W407-4" b2="345 KV" b3="TR83A 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="W407-4" b2="345 KV" b3="TR84 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24770</SeqNum>
    <Name>345L11124 Electric Jct-Lombard 345 kV Line</Name>
    <LastEdit Timestamp="2025-08-04T12:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="111 ELEC" b2="345 KV" b3="11124" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="345 KV" b3="L11124CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="345 KV" b3="L11124CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24780</SeqNum>
    <Name>L345.ElectricJct-Wayne.11126</Name>
    <LastEdit Timestamp="2024-10-30T13:44:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="111 ELEC" b2="345 KV" b3="11126" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="345 KV" b3="L11126CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="345 KV" b3="BT6-7 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24790</SeqNum>
    <Name>L345.GoodingsGrove-EFrankfort.11601</Name>
    <LastEdit Timestamp="2024-10-03T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="66 E FRN" b2="345 KV" b3="11601" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="L11601CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="345 KV" b3="BT8-14CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24810</SeqNum>
    <Name>L345.GoodingsGr-EFrankfort.11602 &amp; TR83 (S) 3-29</Name>
    <LastEdit Timestamp="2026-06-04T13:51:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="66 E FRN" b2="345 KV" b3="11602" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="L11602CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="345 KV" b3="BT1-4ACB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="345 KV" b3="BT1-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="66 E FRN" b2="138 KV" b3="TR83CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24820</SeqNum>
    <Name>L345.GoodingsGrove-Lockport.11604</Name>
    <LastEdit Timestamp="2026-04-02T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="108 LOCK" b2="345 KV" b3="11604" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT1-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="L11604CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24830</SeqNum>
    <Name>L345.GoodingsGrove-BedfordPark.11607</Name>
    <LastEdit Timestamp="2025-05-06T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="116 GOOD" b2="345 KV" b3="11607" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="345 KV" b3="4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="L11607CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24840</SeqNum>
    <Name>L345.GoodingsGrove-BedfordPark.11608</Name>
    <LastEdit Timestamp="2025-05-20T11:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="116 GOOD" b2="345 KV" b3="11608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="345 KV" b3="12-13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="345 KV" b3="13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="L11608CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24850</SeqNum>
    <Name>L345.GoodingsGrove-BlueIsland-Wilton.11613</Name>
    <LastEdit Timestamp="2025-07-23T16:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="112 WILT" b2="345 KV" b3="11613 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="116 GOOD" b2="345 KV" b3="11613 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="L11613CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="76 BLUE" b2="345 KV" b3="11613 2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="76 BLUE" b2="345 KV" b3="L11613 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24860</SeqNum>
    <Name>L345.Gdngs-11614-BlIsl-Wltn.11614 R</Name>
    <LastEdit Timestamp="2024-11-15T11:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="112 WILT" b2="345 KV" b3="11614 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="345 KV" b3="BT2-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="116 GOOD" b2="345 KV" b3="11614 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="L11614CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="76 BLUE" b2="345 KV" b3="11614 2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="76 BLUE" b2="345 KV" b3="L11614 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24870</SeqNum>
    <Name>L345.GoodingsGrove-Lockport.11617</Name>
    <LastEdit Timestamp="2025-07-23T16:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="108 LOCK" b2="345 KV" b3="11617" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="L11617CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24880</SeqNum>
    <Name>L345.GoodingsGrove-Elwood.11620</Name>
    <LastEdit Timestamp="2025-05-02T12:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="116 GOOD" b2="345 KV" b3="11620" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="L11620CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT1112CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24890</SeqNum>
    <Name>L345.GoodingsGrove-Elwood.11622</Name>
    <LastEdit Timestamp="2025-12-11T08:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="116 GOOD" b2="345 KV" b3="11622" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="L11622CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT4-5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24910</SeqNum>
    <Name>L345.ProspectHeights-Liberty.11723 + Prospect.T81</Name>
    <LastEdit Timestamp="2024-12-02T14:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="154 LIBE" b2="345 KV" b3="11723" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="345 KV" b3="TR81" />
      <ContingencyEquipment Action="X" Type="XF" b1="117 PROS" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="117 PROS" b2="138 KV" b3="TR81CT-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="345 KV" b3="BT2-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24930</SeqNum>
    <Name>L345.ProspectHeights-Desplains.11724+Prospect.T84</Name>
    <LastEdit Timestamp="2024-12-02T14:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="46 DESPL" b2="345 KV" b3="11724" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="345 KV" b3="TR84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="117 PROS" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="117 PROS" b2="138 KV" b3="TR84CT-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="345 KV" b3="L11724CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24940</SeqNum>
    <Name>L345.Lombard-Elmhurst.12003+345/138.Elmhurst.TR83</Name>
    <LastEdit Timestamp="2026-04-02T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="120 LOMB" b2="345 KV" b3="12003" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="345 KV" b3="L12003CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="34.5 KV" b3="34C1TR83" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="34.5 KV" b3="34C2TR83" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="34.5 KV" b3="34C3TR83" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="34.5 KV" b3="34C4TR83" />
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="135 ELMH" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="135 ELMH" b2="138 KV" b3="TR83CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="135 ELMH" b2="34.5 KV" b3="TR83CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24950</SeqNum>
    <Name>L345.Lockport-Elmhurst.10807</Name>
    <LastEdit Timestamp="2026-05-14T18:50:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="108 LOCK" b2="345 KV" b3="10807_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="345 KV" b3="2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24960</SeqNum>
    <Name>L345.Lombard-Desplains.12005</Name>
    <LastEdit Timestamp="2026-03-26T10:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="46 DESPL" b2="345 KV" b3="12005" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="345 KV" b3="L12005CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="345 KV" b3="L12005CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24970</SeqNum>
    <Name>L345.Lombard-Desplains.12006</Name>
    <LastEdit Timestamp="2026-04-02T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="46 DESPL" b2="345 KV" b3="12006" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="345 KV" b3="L12006CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="345 KV" b3="L12006CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24980</SeqNum>
    <Name>L345.SilverLake-Libertyville.13821</Name>
    <LastEdit Timestamp="2025-08-21T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="138 SILV" b2="345 KV" b3="13821" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="345 KV" b3="BT3-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>24990</SeqNum>
    <Name>L345.Wayne-SilverLake.14401</Name>
    <LastEdit Timestamp="2024-05-15T10:07:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="138 SILV" b2="345 KV" b3="14401" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="345 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="345 KV" b3="BT12-16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="345 KV" b3="BT5-9CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="345 KV" b3="BT9-10CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25000</SeqNum>
    <Name>L345.Wayne-Tollway.14402 R</Name>
    <LastEdit Timestamp="2025-11-21T12:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="144 WAYN" b2="345 KV" b3="14402" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="144 WAYN" b2="345 KV" b3="L14402 M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="185 TOLL" b2="345 KV" b3="BT4-5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25030</SeqNum>
    <Name>L345.154Libertyville-974Zion.15423</Name>
    <LastEdit Timestamp="2026-01-06T17:06:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="154 LIBE" b2="345 KV" b3="15423" />
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="974 ZION" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="974 ZION" b2="345 KV" b3="BT2-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25040</SeqNum>
    <Name>L345.Nelson-LeeCounty.15501</Name>
    <LastEdit Timestamp="2026-05-26T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="155 NELS" b2="345 KV" b3="15501" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="937 LEE" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="937 LEE" b2="345 KV" b3="BT1-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25060</SeqNum>
    <Name>L345.Nelson-ElectricJct.15502</Name>
    <LastEdit Timestamp="2026-04-02T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="155 NELS" b2="345 KV" b3="15502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="345 KV" b3="L15502CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT4-5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25070</SeqNum>
    <Name>L345.Nelson-Cordova.15503</Name>
    <LastEdit Timestamp="2024-09-19T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="155 NELS" b2="345 KV" b3="15503" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="BT2-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25110</SeqNum>
    <Name>L345.155Nelson-H471.15504</Name>
    <LastEdit Timestamp="2024-10-03T15:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="155 NELS" b2="345 KV" b3="15504" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H471" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="H471" b2="345 KV" b3="TR81 34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25140</SeqNum>
    <Name>L345.CherryValley-Wempletown.15615</Name>
    <LastEdit Timestamp="2026-03-26T10:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="171 WEMP" b2="345 KV" b3="15615" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="345 KV" b3="BT10-13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="345 KV" b3="BT1213CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="171 WEMP" b2="345 KV" b3="BT2-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="171 WEMP" b2="345 KV" b3="BT8-14CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25150</SeqNum>
    <Name>L345.CherryValley-SilverLake.15616</Name>
    <LastEdit Timestamp="2025-06-03T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="138 SILV" b2="345 KV" b3="15616" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="345 KV" b3="BT4-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="345 KV" b3="BT6-7 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25160</SeqNum>
    <Name>L345.Northbrook-Skokie.15925 R</Name>
    <LastEdit Timestamp="2024-12-03T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="88 SKOKI" b2="345 KV" b3="15925" />
      <ContingencyEquipment Action="OP" Type="CB" b1="159 NORT" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="88 SKOKI" b2="345 KV" b3="L15925 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25170</SeqNum>
    <Name>L345.Northbrook-Skokie.15926 R</Name>
    <LastEdit Timestamp="2026-04-02T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="88 SKOKI" b2="345 KV" b3="15926" />
      <ContingencyEquipment Action="OP" Type="CB" b1="159 NORT" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="88 SKOKI" b2="345 KV" b3="L15926 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25180</SeqNum>
    <Name>L345.Plano-ElectricJct.16703</Name>
    <LastEdit Timestamp="2026-04-02T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="111 ELEC" b2="345 KV" b3="16703" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="345 KV" b3="L16703CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="345 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="345 KV" b3="BT5-6 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25190</SeqNum>
    <Name>L345.167Plano-111ElectricJct.16704+Plano.TR81</Name>
    <LastEdit Timestamp="2024-12-09T15:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="111 ELEC" b2="345 KV" b3="16704" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="345 KV" b3="L16704CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="345 KV" b3="BT8-12CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="167 PLAN" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="167 PLAN" b2="138 KV" b3="TR81CT-S" />
      <ContingencyEquipment Action="S" Type="SD" b1="167 PLAN" b2="138 KV" b3="TR81I" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25200</SeqNum>
    <Name>L345.Wempletown-Rockdale.17101 (Tie)</Name>
    <LastEdit Timestamp="2024-05-23T15:26:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="171 WEMP" b2="345 KV" b3="17101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="171 WEMP" b2="345 KV" b3="BT1314CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="171 WEMP" b2="345 KV" b3="BT8-14CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKDAL3" b2="345 KV" b3="6182S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKDAL3" b2="345 KV" b3="6190S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25210</SeqNum>
    <Name>L345.Burnham-BlueIsland.17701 R</Name>
    <LastEdit Timestamp="2025-04-22T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="76 BLUE" b2="345 KV" b3="17701" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT1-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="76 BLUE" b2="345 KV" b3="L17701 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25220</SeqNum>
    <Name>L345.Burnham-BlueIsl.17702 + 345/138.BluIsl.TR81</Name>
    <LastEdit Timestamp="2024-12-02T14:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT8-13CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="76 BLUE" b2="345 KV" b3="17702" />
      <ContingencyEquipment Action="OP" Type="CB" b1="76 BLUE" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="76 BLUE" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="76 BLUE" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="76 BLUE" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25230</SeqNum>
    <Name>L345.Burnham-Munster.17703</Name>
    <LastEdit Timestamp="2025-04-28T15:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="177 BURN" b2="345 KV" b3="BUR-MUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUNSTER2" b2="345 KV" b3="0422_BKR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUNSTER2" b2="345 KV" b3="04_BKR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25240</SeqNum>
    <Name>L345.Burnham-DavisCreek.17704</Name>
    <LastEdit Timestamp="2025-06-03T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="86 DAVIS" b2="345 KV" b3="17704" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT1213CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="345 KV" b3="3-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="345 KV" b3="BT3-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25250</SeqNum>
    <Name>345/138.DavisCreek.TR82</Name>
    <LastEdit Timestamp="2024-10-28T14:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="345 KV" b3="1-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="86 DAVIS" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="86 DAVIS" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25260</SeqNum>
    <Name>L345.Burnham-Sheffield.17705 (TIE)</Name>
    <LastEdit Timestamp="2026-04-02T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT1-5 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="177 BURN" b2="345 KV" b3="BUR-SHE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="345 KV" b3="1112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="345 KV" b3="12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25270</SeqNum>
    <Name>L345.Burnham-Calumet-Taylor.17723</Name>
    <LastEdit Timestamp="2026-04-02T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="150 CALU" b2="345 KV" b3="17723 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="150 CALU" b2="345 KV" b3="17723 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="150 CALU" b2="345 KV" b3="17723I1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="150 CALU" b2="345 KV" b3="17723I2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="150 CALU" b2="345 KV" b3="17723RE1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="150 CALU" b2="345 KV" b3="17723RE2" />
      <ContingencyEquipment Action="S" Type="SD" b1="150 CALU" b2="345 KV" b3="SD23BY" />
      <ContingencyEquipment Action="L" Type="LN" b1="153 TAYL" b2="345 KV" b3="17723 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="153 TAYL" b2="345 KV" b3="17723 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="345 KV" b3="BT1-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT2-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT4-5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25290</SeqNum>
    <Name>L345.Bloom-DavisCreek.17907</Name>
    <LastEdit Timestamp="2025-12-30T14:38:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="86 DAVIS" b2="345 KV" b3="17907" />
      <ContingencyEquipment Action="OP" Type="CB" b1="179 BLOO" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="179 BLOO" b2="345 KV" b3="TR84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="345 KV" b3="5-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="345 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25300</SeqNum>
    <Name>L345.Bloom-Burnham.17908 + 345/138.Burnham.TR81</Name>
    <LastEdit Timestamp="2024-12-02T14:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="177 BURN" b2="345 KV" b3="17908" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT2-13CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT2-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="177 BURN" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="177 BURN" b2="138 KV" b3="TR81CT-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="179 BLOO" b2="345 KV" b3="BT3-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25310</SeqNum>
    <Name>L345.Tollway-Libertyville.18502 R</Name>
    <LastEdit Timestamp="2026-04-02T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="154 LIBE" b2="345 KV" b3="18502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="185 TOLL" b2="345 KV" b3="BT5-6B6M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25320</SeqNum>
    <Name>900Elwood.CT1-4</Name>
    <LastEdit Timestamp="2026-03-31T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="900 ELWO" b2="345 KV" b3="90001 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="900 ELWO" b2="18 KV" b3="EL-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="900 ELWO" b2="18 KV" b3="EL-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="900 ELWO" b2="18 KV" b3="EL-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="900 ELWO" b2="18 KV" b3="EL-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="900 ELWO" b2="345 KV" b3="TR1 18" />
      <ContingencyEquipment Action="X" Type="XF" b1="900 ELWO" b2="345 KV" b3="TR2 18" />
      <ContingencyEquipment Action="X" Type="XF" b1="900 ELWO" b2="345 KV" b3="TR3 18" />
      <ContingencyEquipment Action="X" Type="XF" b1="900 ELWO" b2="345 KV" b3="TR4 18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="18 KV" b3="UEL-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="18 KV" b3="UEL-2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="18 KV" b3="UEL-3CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="18 KV" b3="UEL-4CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25330</SeqNum>
    <Name>900Elwood.CT5-7</Name>
    <LastEdit Timestamp="2026-03-25T14:56:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="900 ELWO" b2="345 KV" b3="90002 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="900 ELWO" b2="18 KV" b3="EL-5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="900 ELWO" b2="18 KV" b3="EL-6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="900 ELWO" b2="18 KV" b3="EL-7" />
      <ContingencyEquipment Action="X" Type="XF" b1="900 ELWO" b2="345 KV" b3="TR5 18" />
      <ContingencyEquipment Action="X" Type="XF" b1="900 ELWO" b2="345 KV" b3="TR6 18" />
      <ContingencyEquipment Action="X" Type="XF" b1="900 ELWO" b2="345 KV" b3="TR7 18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="18 KV" b3="UEL-5CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="18 KV" b3="UEL-6CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="18 KV" b3="UEL-7CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25340</SeqNum>
    <Name>935Kendall.CC1-2</Name>
    <LastEdit Timestamp="2026-03-31T15:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="BT6-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="935 KEND" b2="18 KV" b3="KDLCT-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="935 KEND" b2="18 KV" b3="KDLCT-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="935 KEND" b2="13.5 KV" b3="KDLST-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="935 KEND" b2="13.5 KV" b3="KDLST-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="TR1 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="935 KEND" b2="345 KV" b3="TR1CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="935 KEND" b2="18 KV" b3="TR1CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="935 KEND" b2="13.5 KV" b3="TR1CT-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="TR2 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="935 KEND" b2="345 KV" b3="TR2CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="935 KEND" b2="18 KV" b3="TR2CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="935 KEND" b2="13.5 KV" b3="TR2CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25350</SeqNum>
    <Name>935Kendall.CC3-4</Name>
    <LastEdit Timestamp="2026-03-31T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="BT1-5 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="935 KEND" b2="18 KV" b3="KDLCT-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="935 KEND" b2="18 KV" b3="KDLCT-4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="935 KEND" b2="13.5 KV" b3="KDLST-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="935 KEND" b2="13.5 KV" b3="KDLST-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="TR3 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="935 KEND" b2="345 KV" b3="TR3CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="935 KEND" b2="18 KV" b3="TR3CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="935 KEND" b2="13.5 KV" b3="TR3CT-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="935 KEND" b2="345 KV" b3="TR4 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="935 KEND" b2="345 KV" b3="TR4CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="935 KEND" b2="18 KV" b3="TR4CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="935 KEND" b2="13.5 KV" b3="TR4CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25370</SeqNum>
    <Name>L345.Brokaw-SBloom (AMRN)</Name>
    <LastEdit Timestamp="2024-12-24T13:49:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="345 KV" b3="4553" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROKAW" b2="345 KV" b3="BRO-SBLO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="345 KV" b3="BT4536" />
      <ContingencyEquipment Action="OP" Type="CB" b1="S BLOOM" b2="345 KV" b3="B089" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25380</SeqNum>
    <Name>L345.Lincoln-Wilton.93601 + 936Lincoln.CT1-8</Name>
    <LastEdit Timestamp="2026-04-02T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="112 WILT" b2="345 KV" b3="93601" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="345 KV" b3="BT2-7 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="936 LINC" b2="12 KV" b3="LE-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="936 LINC" b2="12 KV" b3="LE-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="936 LINC" b2="12 KV" b3="LE-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="936 LINC" b2="12 KV" b3="LE-4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="936 LINC" b2="12 KV" b3="LE-5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="936 LINC" b2="12 KV" b3="LE-6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="936 LINC" b2="12 KV" b3="LE-7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="936 LINC" b2="12 KV" b3="LE-8" />
      <ContingencyEquipment Action="X" Type="XF" b1="936 LINC" b2="345 KV" b3="TR1 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="936 LINC" b2="345 KV" b3="TR2 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="936 LINC" b2="345 KV" b3="TR3 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="936 LINC" b2="345 KV" b3="TR4 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25390</SeqNum>
    <Name>937LeeCounty.CT1-8</Name>
    <LastEdit Timestamp="2026-04-01T13:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="937 LEE" b2="345 KV" b3="93701 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="937 LEE" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="937 LEE" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="937 LEE" b2="13.5 KV" b3="LEE31-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="937 LEE" b2="13.5 KV" b3="LEE31-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="937 LEE" b2="13.5 KV" b3="LEE32-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="937 LEE" b2="13.5 KV" b3="LEE32-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="937 LEE" b2="13.5 KV" b3="LEE33-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="937 LEE" b2="13.5 KV" b3="LEE33-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="937 LEE" b2="13.5 KV" b3="LEE34-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="937 LEE" b2="13.5 KV" b3="LEE34-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="937 LEE" b2="345 KV" b3="TR31 13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="937 LEE" b2="345 KV" b3="TR31 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="937 LEE" b2="345 KV" b3="TR32 13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="937 LEE" b2="345 KV" b3="TR32 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="937 LEE" b2="345 KV" b3="TR33 13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="937 LEE" b2="345 KV" b3="TR33 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="937 LEE" b2="345 KV" b3="TR34 13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="937 LEE" b2="345 KV" b3="TR34 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25400</SeqNum>
    <Name>L345.Cordova.BusTie</Name>
    <LastEdit Timestamp="2026-04-02T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="940 CORD" b2="345 KV" b3="94001 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="QC903CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="QC904CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25410</SeqNum>
    <Name>L345.Crete.94501 + Crete.U1-4</Name>
    <LastEdit Timestamp="2025-04-29T17:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="945 CRET" b2="345 KV" b3="94501 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="945 CRET" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="945 CRET" b2="345 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="945 CRET" b2="13.5 KV" b3="CT-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="945 CRET" b2="13.5 KV" b3="CT-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="945 CRET" b2="13.5 KV" b3="CT-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="945 CRET" b2="13.5 KV" b3="CT-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="945 CRET" b2="345 KV" b3="TR1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="945 CRET" b2="345 KV" b3="TR3-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25420</SeqNum>
    <Name>L345.Crete-StJohns.94507 (NIPS) Tie</Name>
    <LastEdit Timestamp="2025-10-07T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="945 CRET" b2="345 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="945 CRET" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="945 CRET" b2="345 KV" b3="CRE-CRET" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS" b2="345 KV" b3="1719" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS" b2="345 KV" b3="19" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRETSTJO" b2="345 KV" b3="CRE-STJO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25430</SeqNum>
    <Name>951Aurora.CT1-2</Name>
    <LastEdit Timestamp="2026-04-03T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="951 AURO" b2="345 KV" b3="95101 Z1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="951 AURO" b2="18 KV" b3="AR-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="951 AURO" b2="18 KV" b3="AR-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="951 AURO" b2="18 KV" b3="ATR2 04" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="951 AURO" b2="345 KV" b3="TR1 18" />
      <ContingencyEquipment Action="X" Type="XF" b1="951 AURO" b2="345 KV" b3="TR2 18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="18 KV" b3="UAR-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="18 KV" b3="UAR-2CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25440</SeqNum>
    <Name>970UpNorth.CT1-12</Name>
    <LastEdit Timestamp="2026-02-10T09:43:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="970 UP N" b2="345 KV" b3="97001 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="970 UP N" b2="345 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="970 UP N" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="970 UP N" b2="345 KV" b3="L97001CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="970 UP N" b2="345 KV" b3="TR31 13" />
      <ContingencyEquipment Action="X" Type="XF" b1="970 UP N" b2="345 KV" b3="TR32 13" />
      <ContingencyEquipment Action="X" Type="XF" b1="970 UP N" b2="345 KV" b3="TR33 13" />
      <ContingencyEquipment Action="X" Type="XF" b1="970 UP N" b2="345 KV" b3="TR34 13" />
      <ContingencyEquipment Action="X" Type="XF" b1="970 UP N" b2="345 KV" b3="TR35 13" />
      <ContingencyEquipment Action="X" Type="XF" b1="970 UP N" b2="345 KV" b3="TR36 13" />
      <ContingencyEquipment Action="U" Type="GEN" b1="970 UP N" b2="13.5 KV" b3="UN-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="970 UP N" b2="13.5 KV" b3="UN-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="970 UP N" b2="13.5 KV" b3="UN-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="970 UP N" b2="13.5 KV" b3="UN-4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="970 UP N" b2="13.5 KV" b3="UN-5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="970 UP N" b2="13.5 KV" b3="UN-6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="970 UP N" b2="13.5 KV" b3="UN-7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="970 UP N" b2="13.5 KV" b3="UN-8" />
      <ContingencyEquipment Action="U" Type="GEN" b1="970 UP N" b2="13.5 KV" b3="UN-9" />
      <ContingencyEquipment Action="U" Type="GEN" b1="970 UP N" b2="13.5 KV" b3="UN10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="970 UP N" b2="13.5 KV" b3="UN11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="970 UP N" b2="13.5 KV" b3="UN12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25450</SeqNum>
    <Name>974Zion.CT1-3</Name>
    <LastEdit Timestamp="2026-04-01T13:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="974 ZION" b2="345 KV" b3="97401 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="974 ZION" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="974 ZION" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="974 ZION" b2="18 KV" b3="LAUXTR11" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="974 ZION" b2="18 KV" b3="LAUXTR3" />
      <ContingencyEquipment Action="X" Type="XF" b1="974 ZION" b2="345 KV" b3="TR11 18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="974 ZION" b2="345 KV" b3="TR11 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="974 ZION" b2="345 KV" b3="TR12 18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="974 ZION" b2="345 KV" b3="TR12 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="974 ZION" b2="345 KV" b3="TR3 18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="974 ZION" b2="345 KV" b3="TR3 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="974 ZION" b2="18 KV" b3="ZE-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="974 ZION" b2="18 KV" b3="ZE11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="974 ZION" b2="18 KV" b3="ZE12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25460</SeqNum>
    <Name>L345.UniversityParkNorth-Olive.97008</Name>
    <LastEdit Timestamp="2025-06-03T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="970 UP N" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="970 UP N" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="OLIVUNPA" b2="345 KV" b3="OLI-UNPA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="345 KV" b3="D1" />
      <ContingencyEquipment Action="L" Type="LN" b1="OLIVE" b2="345 KV" b3="OLI-OLIV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25480</SeqNum>
    <Name>345/138.115 BedfordPark.TR82</Name>
    <LastEdit Timestamp="2025-04-21T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="345 KV" b3="TR82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="115 BEDF" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="115 BEDF" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25490</SeqNum>
    <Name>345/138.115 BedfordPark.TR83</Name>
    <LastEdit Timestamp="2026-03-27T10:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="345 KV" b3="10-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="345 KV" b3="9-10" />
      <ContingencyEquipment Action="X" Type="XF" b1="115 BEDF" b2="345 KV" b3="TR83" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="138 KV" b3="TR83 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25500</SeqNum>
    <Name>345/138.115 BedfordPark.TR84</Name>
    <LastEdit Timestamp="2025-04-21T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="345 KV" b3="TR84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="115 BEDF" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="115 BEDF" b2="138 KV" b3="TR84CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25510</SeqNum>
    <Name>345/138.179Bloom.TR84</Name>
    <LastEdit Timestamp="2024-12-03T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="179 BLOO" b2="345 KV" b3="TR84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="179 BLOO" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="179 BLOO" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="179 BLOO" b2="138 KV" b3="TR84CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25520</SeqNum>
    <Name>345/138.76BlueIsland.TR81 R</Name>
    <LastEdit Timestamp="2024-12-02T13:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="76 BLUE" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="76 BLUE" b2="345 KV" b3="TR81 M" />
      <ContingencyEquipment Action="X" Type="XF" b1="76 BLUE" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="76 BLUE" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25530</SeqNum>
    <Name>345/138.76BlueIsland.TR82</Name>
    <LastEdit Timestamp="2024-12-05T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="76 BLUE" b2="345 KV" b3="TR82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="76 BLUE" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="76 BLUE" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="76 BLUE" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25540</SeqNum>
    <Name>345/138.76BlueIsland.TR83</Name>
    <LastEdit Timestamp="2025-09-02T09:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="76 BLUE" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="76 BLUE" b2="345 KV" b3="TR83CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="76 BLUE" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="76 BLUE" b2="138 KV" b3="TR83CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25550</SeqNum>
    <Name>345/138.76BlueIsland.TR84 R</Name>
    <LastEdit Timestamp="2024-12-02T13:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="76 BLUE" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="76 BLUE" b2="345 KV" b3="TR84 CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="76 BLUE" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="76 BLUE" b2="138 KV" b3="TR84CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25560</SeqNum>
    <Name>345/138.177Burnham.TR81 R</Name>
    <LastEdit Timestamp="2024-12-02T12:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="177 BURN" b2="345 KV" b3="TR81 M" />
      <ContingencyEquipment Action="X" Type="XF" b1="177 BURN" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="177 BURN" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25570</SeqNum>
    <Name>345/138.177Burnham.TR84</Name>
    <LastEdit Timestamp="2024-12-18T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="177 BURN" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="177 BURN" b2="138 KV" b3="TR84CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25580</SeqNum>
    <Name>345/138.156CherryValley.TR81</Name>
    <LastEdit Timestamp="2024-11-27T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="345 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="345 KV" b3="BT1213CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="156 CHER" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="156 CHER" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25590</SeqNum>
    <Name>345/138.156CherryValley.TR82</Name>
    <LastEdit Timestamp="2024-12-02T12:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="156 CHER" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="156 CHER" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25600</SeqNum>
    <Name>345/138.156CherryValley.TR83</Name>
    <LastEdit Timestamp="2024-11-22T10:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="345 KV" b3="TR83" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="156 CHER" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="156 CHER" b2="138 KV" b3="TR83CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25610</SeqNum>
    <Name>765/345.23Collins.TR92</Name>
    <LastEdit Timestamp="2024-12-02T14:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="23 COLLI" b2="765 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="23 COLLI" b2="765 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="23 COLLI" b2="345 KV" b3="TR92 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="23 COLLI" b2="765 KV" b3="TR92CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="23 COLLI" b2="345 KV" b3="TR92CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25650</SeqNum>
    <Name>345/138.13Crawford.TR84</Name>
    <LastEdit Timestamp="2024-11-22T10:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B725 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B727 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="13 CRAWF" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="13 CRAWF" b2="138 KV" b3="TR84CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25660</SeqNum>
    <Name>L138.Dexter-Meigs-Wilksville</Name>
    <LastEdit Timestamp="2025-02-24T10:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEXTER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEXTER" b2="138 KV" b3="B CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEXTER" b2="138 KV" b3="DEX-MEIG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEIGS" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEIGS" b2="138 KV" b3="MEI-MEG2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEIGS2" b2="138 KV" b3="MEI-WIL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25680</SeqNum>
    <Name>345/138.46 Desplains.TR81</Name>
    <LastEdit Timestamp="2024-12-02T12:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="345 KV" b3="T81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="46 DESPL" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="46 DESPL" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25690</SeqNum>
    <Name>345/138.46Desplains.TR82</Name>
    <LastEdit Timestamp="2026-03-31T15:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="46 DESPL" b2="34.5 KV" b3="34C1TR82" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="46 DESPL" b2="34.5 KV" b3="34C2TR82" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="46 DESPL" b2="34.5 KV" b3="34C3TR82" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="46 DESPL" b2="34.5 KV" b3="34C4TR82" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="46 DESPL" b2="34.5 KV" b3="34C5TR82" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="46 DESPL" b2="34.5 KV" b3="34C6TR82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="345 KV" b3="T82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="46 DESPL" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="46 DESPL" b2="138 KV" b3="TR82CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="46 DESPL" b2="34.5 KV" b3="TR82CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25700</SeqNum>
    <Name>345/138.Desplains.TR83</Name>
    <LastEdit Timestamp="2025-12-15T13:13:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L83_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="345 KV" b3="T83" />
      <ContingencyEquipment Action="X" Type="XF" b1="46 DESPL" b2="345 KV" b3="TR83" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25710</SeqNum>
    <Name>345/138.Desplains.TR84</Name>
    <LastEdit Timestamp="2025-03-26T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="46 DESPL" b2="34.5 KV" b3="34C1TR84" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="46 DESPL" b2="34.5 KV" b3="34C2TR84" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="46 DESPL" b2="34.5 KV" b3="34C3TR84" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="46 DESPL" b2="34.5 KV" b3="34C4TR84" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="46 DESPL" b2="34.5 KV" b3="34C5TR84" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="46 DESPL" b2="34.5 KV" b3="34C6TR84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="345 KV" b3="T84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="46 DESPL" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="46 DESPL" b2="138 KV" b3="TR84CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="46 DESPL" b2="34.5 KV" b3="TR84CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25720</SeqNum>
    <Name>345/138.12 Dresden.TR81</Name>
    <LastEdit Timestamp="2026-03-26T10:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="45TR81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="12 DRESD" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="12 DRESD" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25730</SeqNum>
    <Name>345/138.12Dresden.TR83</Name>
    <LastEdit Timestamp="2026-03-31T15:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="TR83" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="12 DRESD" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="12 DRESD" b2="138 KV" b3="TR83CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25740</SeqNum>
    <Name>345/138.12Dresden.TR86</Name>
    <LastEdit Timestamp="2024-11-22T10:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="TR86 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="12 DRESD" b2="345 KV" b3="TR86CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="12 DRESD" b2="138 KV" b3="TR86CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25750</SeqNum>
    <Name>345/138.111ElectricJunction.TR81</Name>
    <LastEdit Timestamp="2026-03-31T15:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="345 KV" b3="TR81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="111 ELEC" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="111 ELEC" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25760</SeqNum>
    <Name>345/138.ElectricJunction.TR82</Name>
    <LastEdit Timestamp="2026-03-30T18:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="345 KV" b3="TR82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="111 ELEC" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="111 ELEC" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25770</SeqNum>
    <Name>345/138.ElectricJunction.TR83</Name>
    <LastEdit Timestamp="2026-03-30T18:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="345 KV" b3="TR83" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="111 ELEC" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="111 ELEC" b2="138 KV" b3="TR83CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="111 ELEC" b2="34.5 KV" b3="TR83CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25780</SeqNum>
    <Name>345/138.ElectricJunction.TR84</Name>
    <LastEdit Timestamp="2024-12-12T13:42:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="345 KV" b3="TR84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="111 ELEC" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="111 ELEC" b2="138 KV" b3="TR84CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="111 ELEC" b2="34.5 KV" b3="TR84CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25790</SeqNum>
    <Name>345/138.135Elmhurst.TR81</Name>
    <LastEdit Timestamp="2026-05-22T11:54:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="345 KV" b3="1-6" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="34.5 KV" b3="34C1TR81" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="34.5 KV" b3="34C2TR81" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="34.5 KV" b3="34C3TR81" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="34.5 KV" b3="34C4TR81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="135 ELMH" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="135 ELMH" b2="138 KV" b3="TR81CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="135 ELMH" b2="34.5 KV" b3="TR81CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25800</SeqNum>
    <Name>345/138.135ElmHurst.TR83 R</Name>
    <LastEdit Timestamp="2025-06-18T12:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="34.5 KV" b3="34C1TR83" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="34.5 KV" b3="34C2TR83" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="34.5 KV" b3="34C3TR83" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="34.5 KV" b3="34C4TR83" />
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="135 ELMH" b2="345 KV" b3="TR83 M" />
      <ContingencyEquipment Action="X" Type="XF" b1="135 ELMH" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="135 ELMH" b2="138 KV" b3="TR83CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="135 ELMH" b2="34.5 KV" b3="TR83CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25820</SeqNum>
    <Name>345/138.172GolfMill.TR81 R</Name>
    <LastEdit Timestamp="2025-04-23T16:04:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="172 GOLF" b2="34.5 KV" b3="34C1TR81" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="172 GOLF" b2="34.5 KV" b3="34C2TR81" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="172 GOLF" b2="34.5 KV" b3="34C3TR81" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="172 GOLF" b2="34.5 KV" b3="34C4TR81" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="172 GOLF" b2="34.5 KV" b3="34C5TR81" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="172 GOLF" b2="34.5 KV" b3="34C6TR81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="172 GOLF" b2="345 KV" b3="TR81 M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="34.5 KV" b3="TR81-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="34.5 KV" b3="TR81-3CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="34.5 KV" b3="TR81-5CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="172 GOLF" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="172 GOLF" b2="138 KV" b3="TR81CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="172 GOLF" b2="34.5 KV" b3="TR81CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25830</SeqNum>
    <Name>345/138.172GolfMill.TR82 R</Name>
    <LastEdit Timestamp="2024-12-02T12:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="172 GOLF" b2="345 KV" b3="TR82 M" />
      <ContingencyEquipment Action="X" Type="XF" b1="172 GOLF" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="172 GOLF" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25840</SeqNum>
    <Name>345/138.116GoodingsGrove.TR81 R</Name>
    <LastEdit Timestamp="2024-11-22T10:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="116 GOOD" b2="345 KV" b3="TR81 CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="116 GOOD" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="116 GOOD" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25850</SeqNum>
    <Name>345/138.116GoodingsGrove.TR83 R</Name>
    <LastEdit Timestamp="2024-11-22T10:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="116 GOOD" b2="345 KV" b3="TR83 CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="116 GOOD" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="116 GOOD" b2="138 KV" b3="TR83CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25880</SeqNum>
    <Name>345/138.1Lasalle.TR81 R</Name>
    <LastEdit Timestamp="2026-01-08T08:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="1 LASALL" b2="345 KV" b3="TR81 M" />
      <ContingencyEquipment Action="X" Type="XF" b1="1 LASALL" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="1 LASALL" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25890</SeqNum>
    <Name>345/138.103Lisle.TR82</Name>
    <LastEdit Timestamp="2025-08-25T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="103 LISL" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="103 LISL" b2="138 KV" b3="TR82CT-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="345 KV" b3="TR82HCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25900</SeqNum>
    <Name>345/138.103Lisle.TR83</Name>
    <LastEdit Timestamp="2025-08-25T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="103 LISL" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="103 LISL" b2="138 KV" b3="TR83CT-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="345 KV" b3="TR83HCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25910</SeqNum>
    <Name>345/138.103Lisle.TR84</Name>
    <LastEdit Timestamp="2025-08-25T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="103 LISL" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="103 LISL" b2="138 KV" b3="TR84CT-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="345 KV" b3="TR84HCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25920</SeqNum>
    <Name>345/138.120Lombard.TR82 R</Name>
    <LastEdit Timestamp="2024-12-02T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="120 LOMB" b2="345 KV" b3="TR82 M" />
      <ContingencyEquipment Action="X" Type="XF" b1="120 LOMB" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="120 LOMB" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25930</SeqNum>
    <Name>345/138.120Lombard.TR84 R</Name>
    <LastEdit Timestamp="2024-12-02T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="120 LOMB" b2="345 KV" b3="TR84 M" />
      <ContingencyEquipment Action="X" Type="XF" b1="120 LOMB" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="120 LOMB" b2="138 KV" b3="TR84CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25940</SeqNum>
    <Name>345/138.McCook.TR82</Name>
    <LastEdit Timestamp="2024-05-15T10:13:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="345 KV" b3="10-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="345 KV" b3="9-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="51 MC CO" b2="345 KV" b3="TR82_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25950</SeqNum>
    <Name>345/138.McCook.TR84</Name>
    <LastEdit Timestamp="2024-05-15T10:20:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="345 KV" b3="1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="51 MC CO" b2="345 KV" b3="TR84_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25960</SeqNum>
    <Name>345/138.155Nelson.TR82</Name>
    <LastEdit Timestamp="2026-01-02T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="155 NELS" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="155 NELS" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>25970</SeqNum>
    <Name>345/138.155Nelson.TR84</Name>
    <LastEdit Timestamp="2026-01-02T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="155 NELS" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="155 NELS" b2="138 KV" b3="TR84CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26000</SeqNum>
    <Name>345/138.Northbrook.TR82</Name>
    <LastEdit Timestamp="2025-01-30T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="159 NORT" b2="345 KV" b3="TR82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="159 NORT" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="159 NORT" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="159 NORT" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26020</SeqNum>
    <Name>765/345.167Plano.TR93</Name>
    <LastEdit Timestamp="2025-12-26T12:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="345 KV" b3="BT10-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="765 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="345 KV" b3="BT8-12CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="167 PLAN" b2="765 KV" b3="TR93CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="167 PLAN" b2="345 KV" b3="TR93CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26030</SeqNum>
    <Name>765/345.167Plano.TR94</Name>
    <LastEdit Timestamp="2025-12-26T12:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="345 KV" b3="BT3-5CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="765 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="167 PLAN" b2="765 KV" b3="TR94CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="167 PLAN" b2="345 KV" b3="TR94CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26040</SeqNum>
    <Name>345/138.80Pontiac.TR82</Name>
    <LastEdit Timestamp="2024-12-24T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="80 PONTI" b2="138 KV" b3="BT2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="80 PONTI" b2="345 KV" b3="TR82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="80 PONTI" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="80 PONTI" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="80 PONTI" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26060</SeqNum>
    <Name>345/138.117ProspectHeights.TR81</Name>
    <LastEdit Timestamp="2024-11-22T10:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="345 KV" b3="TR81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="117 PROS" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="117 PROS" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26090</SeqNum>
    <Name>345/138.117ProspectHeights.TR84</Name>
    <LastEdit Timestamp="2024-12-02T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="345 KV" b3="TR84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="117 PROS" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="117 PROS" b2="138 KV" b3="TR84CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26130</SeqNum>
    <Name>345/138.88Skokie.TR81</Name>
    <LastEdit Timestamp="2024-12-03T14:14:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="345 KV" b3="TR81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="88 SKOKI" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="88 SKOKI" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26140</SeqNum>
    <Name>345/138.88Skokie.TR82</Name>
    <LastEdit Timestamp="2024-12-03T14:14:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="345 KV" b3="TR82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="88 SKOKI" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="88 SKOKI" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26150</SeqNum>
    <Name>345/138.88Skokie.TR83</Name>
    <LastEdit Timestamp="2024-12-03T14:14:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="345 KV" b3="TR83" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="88 SKOKI" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="88 SKOKI" b2="138 KV" b3="TR83CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26160</SeqNum>
    <Name>345/138.88Skokie.TR84</Name>
    <LastEdit Timestamp="2024-12-03T14:14:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="345 KV" b3="TR84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="88 SKOKI" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="88 SKOKI" b2="138 KV" b3="TR84CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26180</SeqNum>
    <Name>345/138.153Taylor.TR82</Name>
    <LastEdit Timestamp="2024-11-27T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT2829CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT2930CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="153 TAYL" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="153 TAYL" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26200</SeqNum>
    <Name>345/138.StateLine.TR81</Name>
    <LastEdit Timestamp="2024-12-24T13:50:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="345 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="7 STATE" b2="345 KV" b3="BT3-4 M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="7 STATE" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="7 STATE" b2="138 KV" b3="TR81CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="7 STATE" b2="34.5 KV" b3="TR81CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26210</SeqNum>
    <Name>345/138.StateLine.TR82</Name>
    <LastEdit Timestamp="2025-07-22T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="345 KV" b3="BT2-4 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="7 STATE" b2="345 KV" b3="BT3-4 M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="7 STATE" b2="345 KV" b3="TR82CT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26240</SeqNum>
    <Name>345/138.171Wempletown.TR84</Name>
    <LastEdit Timestamp="2024-11-27T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="171 WEMP" b2="345 KV" b3="TR84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="171 WEMP" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="171 WEMP" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="171 WEMP" b2="138 KV" b3="TR84CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26250</SeqNum>
    <Name>765/345.112Wilton.TR93</Name>
    <LastEdit Timestamp="2024-12-18T12:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="765 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="765 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="112 WILT" b2="765 KV" b3="TR93CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="112 WILT" b2="345 KV" b3="TR93CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26260</SeqNum>
    <Name>765/345.Wilton.TR94</Name>
    <LastEdit Timestamp="2025-05-28T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="765 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="765 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="112 WILT" b2="765 KV" b3="TR94CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="112 WILT" b2="345 KV" b3="TR94CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26270</SeqNum>
    <Name>11 FISK TR75 (SERIES DEV)</Name>
    <LastEdit Timestamp="2025-10-15T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="12 KV" b3="75B13CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="12 KV" b3="75B23CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="11 FISK" b2="138 KV" b3="TR75 M" />
      <ContingencyEquipment Action="S" Type="SD" b1="11 FISK" b2="138 KV" b3="TR75 Z1" />
      <ContingencyEquipment Action="X" Type="XF" b1="11 FISK" b2="138 KV" b3="TR75B 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="11 FISK" b2="138 KV" b3="TR75R 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26290</SeqNum>
    <Name>138/69.45Jefferson.TR77</Name>
    <LastEdit Timestamp="2025-06-18T13:10:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="45 JEFFE" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="45 JEFFE" b2="138 KV" b3="TR77 69" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="45 JEFFE" b2="69 KV" b3="TR77 D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26310</SeqNum>
    <Name>L138.13Crawf-45Jeff.1320 + 138/69.45Jeff.TR79</Name>
    <LastEdit Timestamp="2024-06-12T12:05:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="13 CRAWF" b2="138 KV" b3="1320" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B723 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B725 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="69 KV" b3="BT622 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="69 KV" b3="BT624 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="45 JEFFE" b2="138 KV" b3="TR79 69" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26320</SeqNum>
    <Name>138/69.160 Alpine.TR76 R</Name>
    <LastEdit Timestamp="2025-04-22T11:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="160 ALPI" b2="138 KV" b3="TR76 69" />
      <ContingencyEquipment Action="OP" Type="CB" b1="160 ALPI" b2="69 KV" b3="TR76 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="160 ALPI" b2="138 KV" b3="TR76 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26330</SeqNum>
    <Name>138/69.163 RoscoeBert.TR77 R</Name>
    <LastEdit Timestamp="2025-04-22T11:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="163 ROSC" b2="138 KV" b3="TR77 69" />
      <ContingencyEquipment Action="OP" Type="CB" b1="163 ROSC" b2="69 KV" b3="TR77 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="163 ROSC" b2="138 KV" b3="TR77 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26340</SeqNum>
    <Name>138/69/12.Sabrooke.TR76</Name>
    <LastEdit Timestamp="2024-12-12T13:36:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="194 SABR" b2="138 KV" b3="95201" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="138 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="138 KV" b3="L15626CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="138 KV" b3="L17113CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="138 KV" b3="L95201CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="194 SABR" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="69 KV" b3="TR76 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="194 SABR" b2="138 KV" b3="TR76CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="194 SABR" b2="69 KV" b3="TR76CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26350</SeqNum>
    <Name>138/69/12.Sabrooke.TR79</Name>
    <LastEdit Timestamp="2024-10-08T13:16:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="194 SABR" b2="138 KV" b3="98221" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="138 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="138 KV" b3="L15622CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="138 KV" b3="L19414CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="138 KV" b3="L98221CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="194 SABR" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="69 KV" b3="TR79 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="194 SABR" b2="138 KV" b3="TR79CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="194 SABR" b2="69 KV" b3="TR79CT-S" />
      <ContingencyEquipment Action="U" Type="GEN" b1="982 ROCK" b2="16 KV" b3="RO21" />
      <ContingencyEquipment Action="X" Type="XF" b1="982 ROCK" b2="138 KV" b3="TR21 16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26360</SeqNum>
    <Name>L138.1Lasalle-0108-77Mazon.0108</Name>
    <LastEdit Timestamp="2024-12-10T16:01:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="1 LASALL" b2="138 KV" b3="0108 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="77 MAZON" b2="138 KV" b3="0108 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="0108" b2="138 KV" b3="0108 3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="0108" b2="138 KV" b3="0820 S" />
      <ContingencyEquipment Action="L" Type="LN" b1="1 LASALL" b2="138 KV" b3="0108 4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="138 KV" b3="L0108 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="1 LASALL" b2="138 KV" b3="TR041 04" />
      <ContingencyEquipment Action="OP" Type="CB" b1="77 MAZON" b2="138 KV" b3="1205 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26370</SeqNum>
    <Name>L138.7StateLine-137WashingtonPark.0702</Name>
    <LastEdit Timestamp="2025-10-07T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="7 STATE" b2="138 KV" b3="0702" />
      <ContingencyEquipment Action="OP" Type="CB" b1="137 WASH" b2="138 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="137 WASH" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="137 WASH" b2="138 KV" b3="TR75-X12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="137 WASH" b2="138 KV" b3="TR75-Y12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="138 KV" b3="L0702 CB" />
      <ContingencyEquipment Action="P" Type="XF" b1="7 STATE" b2="138 KV" b3="P0702" />
      <ContingencyEquipment Action="X" Type="XF" b1="7 STATE" b2="138 KV" b3="P0702T38" />
      <ContingencyEquipment Action="X" Type="XF" b1="7 STATE" b2="138 KV" b3="Z0702T38" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26390</SeqNum>
    <Name>L138.StateLine-0704-Z100-RiverEC-Z715.0704</Name>
    <LastEdit Timestamp="2025-09-04T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="7 STATE" b2="138 KV" b3="0704 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="0704" b2="138 KV" b3="0704 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="0704" b2="138 KV" b3="0704 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="0704" b2="138 KV" b3="0704 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="955 RIVE" b2="138 KV" b3="0704 5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="138 KV" b3="L0704 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="955 RIVE" b2="138 KV" b3="L0704 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="Z100" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="Z100" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="Z715" b2="138 KV" b3="L0704 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26410</SeqNum>
    <Name>L138.7_State-150_Calumet.0706</Name>
    <LastEdit Timestamp="2024-06-12T11:08:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="150 CALU" b2="138 KV" b3="0706" />
      <ContingencyEquipment Action="OP" Type="CB" b1="150 CALU" b2="138 KV" b3="L0706 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="138 KV" b3="L0706 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26420</SeqNum>
    <Name>L138.7_State-150_Calumet.0707</Name>
    <LastEdit Timestamp="2024-06-12T11:17:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="150 CALU" b2="138 KV" b3="L0707 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="150 CALU" b2="138 KV" b3="0707" />
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="138 KV" b3="L0707 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26430</SeqNum>
    <Name>L138.7StateLine-0708-150Calumet-170Harbor.0708</Name>
    <LastEdit Timestamp="2026-02-10T09:44:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="7 STATE" b2="138 KV" b3="0708 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="170 HARB" b2="138 KV" b3="0708 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="150 CALU" b2="138 KV" b3="0708 5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="150 CALU" b2="138 KV" b3="L0708 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="170 HARB" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="138 KV" b3="L0708CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26440</SeqNum>
    <Name>L138.7_State-150_Calumet.0716</Name>
    <LastEdit Timestamp="2024-06-12T11:31:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="150 CALU" b2="138 KV" b3="0716" />
      <ContingencyEquipment Action="OP" Type="CB" b1="150 CALU" b2="138 KV" b3="L0716 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="138 KV" b3="L0716 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26450</SeqNum>
    <Name>L138.Joliet-0901-DavisCreek-EFrankfort.0901 G</Name>
    <LastEdit Timestamp="2026-06-04T13:57:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="9 JOLIET" b2="138 KV" b3="0901 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="0901" b2="138 KV" b3="0901 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="0901" b2="138 KV" b3="0901 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="0901" b2="138 KV" b3="0901 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="0901" b2="138 KV" b3="0901 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="86 DAVIS" b2="138 KV" b3="0901 7" />
      <ContingencyEquipment Action="S" Type="SD" b1="0901" b2="138 KV" b3="0901 X" />
      <ContingencyEquipment Action="L" Type="LN" b1="0901" b2="138 KV" b3="0901 Z" />
      <ContingencyEquipment Action="L" Type="LN" b1="0901" b2="138 KV" b3="0901 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="140 FRAN" b2="138 KV" b3="0901 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="0901" b2="138 KV" b3="0901 Z3" />
      <ContingencyEquipment Action="L" Type="LN" b1="0901" b2="138 KV" b3="0901-MAN" />
      <ContingencyEquipment Action="S" Type="SD" b1="0901" b2="138 KV" b3="0901_8" />
      <ContingencyEquipment Action="S" Type="SD" b1="0901" b2="138 KV" b3="0901_Z5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="140 FRAN" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="183_MANT" b2="138 KV" b3="20-21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="183_MANT" b2="138 KV" b3="21-22" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="406 NEW" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="406 NEW" b2="138 KV" b3="L0901 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="409 JOLI" b2="138 KV" b3="0901CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="409 JOLI" b2="138 KV" b3="BT2-3CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="474 BRIG" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="CL" Type="CB" b1="66 E FRN" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="138 KV" b3="L0901 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="138 KV" b3="L0901 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="9 JOLIET" b2="138 KV" b3="0901B2CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26460</SeqNum>
    <Name>L138.9Joliet-0902-86DavisCrk-66EFrankfort.0902</Name>
    <LastEdit Timestamp="2024-12-09T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="9 JOLIET" b2="138 KV" b3="0902 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="0902" b2="138 KV" b3="0902 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="0902" b2="138 KV" b3="0902 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="0902" b2="138 KV" b3="0902 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="0902" b2="138 KV" b3="0902 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="86 DAVIS" b2="138 KV" b3="0902 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="140 FRAN" b2="138 KV" b3="0902 8" />
      <ContingencyEquipment Action="S" Type="SD" b1="0902" b2="138 KV" b3="0902 X" />
      <ContingencyEquipment Action="L" Type="LN" b1="0902" b2="138 KV" b3="0902 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="0902" b2="138 KV" b3="0902 Z2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="140 FRAN" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="406 NEW" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="406 NEW" b2="138 KV" b3="L0902 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="0902" b2="138 KV" b3="0902 Z" />
      <ContingencyEquipment Action="OP" Type="CB" b1="409 JOLI" b2="138 KV" b3="0902CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="409 JOLI" b2="138 KV" b3="BT2-3CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="474 BRIG" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="138 KV" b3="L0902 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="138 KV" b3="L0902 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="9 JOLIET" b2="138 KV" b3="0902B1CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26470</SeqNum>
    <Name>L138.9Joliet-0903-12Dresden.0903</Name>
    <LastEdit Timestamp="2026-01-16T13:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="9 JOLIET" b2="138 KV" b3="0903 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="0903" b2="138 KV" b3="0903 11" />
      <ContingencyEquipment Action="S" Type="SD" b1="0903" b2="138 KV" b3="0903 12" />
      <ContingencyEquipment Action="S" Type="SD" b1="0903" b2="138 KV" b3="0903 13" />
      <ContingencyEquipment Action="S" Type="SD" b1="0903" b2="138 KV" b3="0903 14" />
      <ContingencyEquipment Action="S" Type="SD" b1="0903" b2="138 KV" b3="0903 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="0903" b2="138 KV" b3="0903 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="138 KV" b3="0903 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="0903" b2="138 KV" b3="0903 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="0903" b2="138 KV" b3="0903 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="0903" b2="138 KV" b3="0903 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="0903" b2="138 KV" b3="0903 9" />
      <ContingencyEquipment Action="L" Type="LN" b1="72 GOOSE" b2="138 KV" b3="0903 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="0903" b2="138 KV" b3="0903 Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="L0903 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="444 MINO" b2="138 KV" b3="0903R CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="444 MINO" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="X" Type="XF" b1="72 GOOSE" b2="138 KV" b3="TR77 34" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="72 GOOSE" b2="138 KV" b3="TR77 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="9 JOLIET" b2="138 KV" b3="0903B1CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="J305-2" b2="138 KV" b3="BT0410D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="J305-2" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="J326" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="J326" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="J370" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="J370" b2="138 KV" b3="L0903 CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="J390" b2="138 KV" b3="TR767734" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26480</SeqNum>
    <Name>L138.9Joliet-0904-12Dresden.0904</Name>
    <LastEdit Timestamp="2024-12-10T15:35:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="9 JOLIET" b2="138 KV" b3="0904 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="0904" b2="138 KV" b3="0904 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="0904" b2="138 KV" b3="0904 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="138 KV" b3="0904 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="0904" b2="138 KV" b3="0904 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="0904" b2="138 KV" b3="0904 6" />
      <ContingencyEquipment Action="S" Type="SD" b1="0904" b2="138 KV" b3="0904 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="72 GOOSE" b2="138 KV" b3="0904 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="0904" b2="138 KV" b3="0904 Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="L0904 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="444 MINO" b2="138 KV" b3="0904B CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="444 MINO" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="X" Type="XF" b1="72 GOOSE" b2="138 KV" b3="TR76 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="72 GOOSE" b2="34.5 KV" b3="TR76 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="9 JOLIET" b2="138 KV" b3="0904B2CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="J305-2" b2="138 KV" b3="BT0410D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="J305-2" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="J326" b2="138 KV" b3="BT2-3 D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="J326" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26500</SeqNum>
    <Name>L138.9Joliet-0906-18WillCounty.0906</Name>
    <LastEdit Timestamp="2025-03-18T15:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="0906" b2="138 KV" b3="0905 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="9 JOLIET" b2="138 KV" b3="0906 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="0906" b2="138 KV" b3="0906 10" />
      <ContingencyEquipment Action="S" Type="SD" b1="0906" b2="138 KV" b3="0906 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="0906" b2="138 KV" b3="0906 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="0906" b2="138 KV" b3="0906 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="0906" b2="138 KV" b3="0906 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="18 WILL" b2="138 KV" b3="0906 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="0906" b2="138 KV" b3="0906 7" />
      <ContingencyEquipment Action="S" Type="SD" b1="0906" b2="138 KV" b3="0906 8" />
      <ContingencyEquipment Action="L" Type="LN" b1="0906" b2="138 KV" b3="0906 9" />
      <ContingencyEquipment Action="L" Type="LN" b1="0906" b2="138 KV" b3="0906 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="0906" b2="138 KV" b3="0906 Z2" />
      <ContingencyEquipment Action="S" Type="SD" b1="18 WILL" b2="138 KV" b3="0906" />
      <ContingencyEquipment Action="OP" Type="CB" b1="18 WILL" b2="138 KV" b3="L0906 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="18 WILL" b2="138 KV" b3="L0906TBD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="436 HILL" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="456 JOL" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="9 JOLIET" b2="138 KV" b3="0906B2CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="J332-1" b2="138 KV" b3="BT0670LS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="J332-1" b2="138 KV" b3="BT1140LS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="J332-1" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="J332-1" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="J332-2" b2="138 KV" b3="BT0630D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="J332-2" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26510</SeqNum>
    <Name>L138.Joliet-Rockdale-Plainfield-WolfsCrossing.0907</Name>
    <LastEdit Timestamp="2025-11-14T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="0907" b2="138 KV" b3="0720CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="9 JOLIET" b2="138 KV" b3="0907 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="0907" b2="138 KV" b3="0907 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="0907" b2="138 KV" b3="0907 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="0907" b2="138 KV" b3="0907 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="0907" b2="138 KV" b3="0907 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="0907" b2="138 KV" b3="0907 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="0907" b2="138 KV" b3="0907 8" />
      <ContingencyEquipment Action="S" Type="SD" b1="0907" b2="138 KV" b3="0907 9" />
      <ContingencyEquipment Action="L" Type="LN" b1="0907" b2="138 KV" b3="0907 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="0907" b2="138 KV" b3="0907 Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="143 WOLF" b2="138 KV" b3="L0907 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="436 HILL" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="439 ROCK" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="454 PLAI" b2="138 KV" b3="0728CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="454 PLAI" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="9 JOLIET" b2="138 KV" b3="0907B2CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="W601" b2="138 KV" b3="BT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W601" b2="138 KV" b3="L0907 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26520</SeqNum>
    <Name>L138.9Joliet-0908-431Shorewood.0908</Name>
    <LastEdit Timestamp="2024-11-21T14:28:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="9 JOLIET" b2="138 KV" b3="0908 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="431 SHOR" b2="138 KV" b3="0908 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="0908" b2="138 KV" b3="0908 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="436 HILL" b2="138 KV" b3="0908 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="439 ROCK" b2="138 KV" b3="0908 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="431 SHOR" b2="138 KV" b3="91170908" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="431 SHOR" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="431 SHOR" b2="138 KV" b3="L0908 CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="436 HILL" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="439 ROCK" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="9 JOLIET" b2="138 KV" b3="0908B1CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26530</SeqNum>
    <Name>L138.11Fisk-840Quarry-126State.1106 + 11Fisk.TR71</Name>
    <LastEdit Timestamp="2025-12-29T10:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="11 FISK" b2="138 KV" b3="1106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="12 KV" b3="71B21CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="12 KV" b3="71B22CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="11 FISK" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="S" Type="SD" b1="11 FISK" b2="12 KV" b3="TR71B1Z1" />
      <ContingencyEquipment Action="S" Type="SD" b1="11 FISK" b2="12 KV" b3="TR71B2Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="840 QUAR" b2="138 KV" b3="1106 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="126 STAT" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="126 STAT" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="840 QUAR" b2="138 KV" b3="I1106" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="840 QUAR" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26550</SeqNum>
    <Name>L138.11Fisk-840Quarry.1107</Name>
    <LastEdit Timestamp="2026-04-01T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="1-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="11 FISK" b2="138 KV" b3="1107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="840 QUAR" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26560</SeqNum>
    <Name>L138.11Fisk-840Quarry-126State.1108</Name>
    <LastEdit Timestamp="2024-12-09T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="11 FISK" b2="138 KV" b3="1108" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT1314CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT1415CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="840 QUAR" b2="138 KV" b3="1108 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="126 STAT" b2="138 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="126 STAT" b2="138 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="840 QUAR" b2="138 KV" b3="I1108" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="840 QUAR" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26570</SeqNum>
    <Name>L138.Fisk-Quarry.L1109</Name>
    <LastEdit Timestamp="2024-10-24T14:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="10-11" />
      <ContingencyEquipment Action="L" Type="LN" b1="11 FISK" b2="138 KV" b3="1109" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="840 QUAR" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26580</SeqNum>
    <Name>L138.11Fisk-90Dekoven.1110 G SPOG 2-27</Name>
    <LastEdit Timestamp="2025-10-27T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="11 FISK" b2="138 KV" b3="1110" />
      <ContingencyEquipment Action="S" Type="SD" b1="11 FISK" b2="138 KV" b3="1110 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="90 DEKOV" b2="138 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="90 DEKOV" b2="138 KV" b3="BT7-8 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26600</SeqNum>
    <Name>L138.11Fisk-90Dekoven-36Madison.1111 G SPOG 2-27</Name>
    <LastEdit Timestamp="2025-10-27T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="11 FISK" b2="138 KV" b3="1111" />
      <ContingencyEquipment Action="S" Type="SD" b1="11 FISK" b2="138 KV" b3="1111 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT1213CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT1314CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="90 DEKOV" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="90 DEKOV" b2="138 KV" b3="BT4-5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26620</SeqNum>
    <Name>L138.12Dresden-1205-77Mazon.1205</Name>
    <LastEdit Timestamp="2024-12-10T15:37:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="L1205 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="138 KV" b3="1205 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="1205" b2="138 KV" b3="1205 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="77 MAZON" b2="138 KV" b3="1205 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="1205" b2="138 KV" b3="1205 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="1205" b2="138 KV" b3="1205 9" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="77 MAZON" b2="138 KV" b3="0505CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="77 MAZON" b2="138 KV" b3="1205 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="77 MAZON" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="J339" b2="138 KV" b3="BT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="J339" b2="138 KV" b3="L1205 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="J375" b2="138 KV" b3="L1205 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26630</SeqNum>
    <Name>L138.12Dresden-1206-433ChannahonWest.1206</Name>
    <LastEdit Timestamp="2026-02-10T09:46:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="L1206 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="138 KV" b3="1206 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="1206" b2="138 KV" b3="1206 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="1206" b2="138 KV" b3="1206 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="1206" b2="138 KV" b3="1206 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="1206" b2="138 KV" b3="1206_8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="433 CHAN" b2="138 KV" b3="1206 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="J339" b2="138 KV" b3="BT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="J339" b2="138 KV" b3="L1206 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="J375" b2="138 KV" b3="L1206 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26640</SeqNum>
    <Name>L138.12Dresden-1207-149Wilmington.1207</Name>
    <LastEdit Timestamp="2024-12-09T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="138 KV" b3="1207 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="138 KV" b3="1207 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="L1207 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="12 DRESD" b2="138 KV" b3="TR041 04" />
      <ContingencyEquipment Action="L" Type="LN" b1="1207" b2="138 KV" b3="1207 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="149 WILM" b2="138 KV" b3="1207 Z2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="149 WILM" b2="138 KV" b3="BT1-6 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="149 WILM" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="149 WILM" b2="138 KV" b3="BT5-6 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26650</SeqNum>
    <Name>L138.12 Dresden-1210-91 Cargo.1210</Name>
    <LastEdit Timestamp="2026-01-16T12:58:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="L1210 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="138 KV" b3="1210 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="1210" b2="138 KV" b3="1210 2LN" />
      <ContingencyEquipment Action="S" Type="SD" b1="1210" b2="138 KV" b3="1210 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="1210" b2="138 KV" b3="1210 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="1210" b2="138 KV" b3="1210 5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="91 CARGO" b2="138 KV" b3="L1210" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="J370" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="J370" b2="138 KV" b3="L1210 CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="J390" b2="138 KV" b3="TR787934" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26670</SeqNum>
    <Name>L138.Ridgeland-D799-Crawford.1306</Name>
    <LastEdit Timestamp="2026-04-01T13:57:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="13 CRAWF" b2="138 KV" b3="1306 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="192 RIDG" b2="138 KV" b3="1306 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="192 RIDG" b2="138 KV" b3="BT1-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="192 RIDG" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="D799" b2="138 KV" b3="1306 4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="D799" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="D799" b2="138 KV" b3="L1306 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26680</SeqNum>
    <Name>L138.Crawford-D799-Ridgeland.1315 G SPOG 2-25</Name>
    <LastEdit Timestamp="2025-08-01T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="11-12" />
      <ContingencyEquipment Action="L" Type="LN" b1="13 CRAWF" b2="138 KV" b3="1315 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT1213CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="13 CRAWF" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="13 CRAWF" b2="138 KV" b3="CAP4" />
      <ContingencyEquipment Action="L" Type="LN" b1="192 RIDG" b2="138 KV" b3="1315 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="192 RIDG" b2="138 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="192 RIDG" b2="138 KV" b3="BT1113CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="192 RIDG" b2="138 KV" b3="BT4-14CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="D799" b2="138 KV" b3="1315 3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="D799" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="D799" b2="138 KV" b3="L1315 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26700</SeqNum>
    <Name>L138.13Crawford-11Fisk.1317</Name>
    <LastEdit Timestamp="2025-10-27T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="13 CRAWF" b2="138 KV" b3="1317" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT3-16CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="112-212" />
      <ContingencyEquipment Action="S" Type="SD" b1="13 CRAWF" b2="138 KV" b3="1317 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B711 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B714 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26710</SeqNum>
    <Name>L138.13Crawford-11Fisk.1318</Name>
    <LastEdit Timestamp="2025-10-28T11:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="13 CRAWF" b2="138 KV" b3="1318 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="L1318 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="13 CRAWF" b2="138 KV" b3="1318 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B724 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B726 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26720</SeqNum>
    <Name>L138.13Crawford-45Jefferson.1320 + Jefferson.TR79</Name>
    <LastEdit Timestamp="2025-10-28T11:27:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="13 CRAWF" b2="138 KV" b3="1320" />
      <ContingencyEquipment Action="S" Type="SD" b1="13 CRAWF" b2="138 KV" b3="1320 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B723 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B725 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="69 KV" b3="BT622 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="69 KV" b3="BT624 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="45 JEFFE" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="45 JEFFE" b2="138 KV" b3="TR79 69" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26730</SeqNum>
    <Name>L138.115BedfordPk-1322-33Hayford-63Sawyer.1322</Name>
    <LastEdit Timestamp="2025-08-04T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="104 FORD" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="104 FORD" b2="138 KV" b3="L1322 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="138 KV" b3="L1322 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="115 BEDF" b2="138 KV" b3="L1322TBD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="115 BEDF" b2="138 KV" b3="TR79 34" />
      <ContingencyEquipment Action="L" Type="LN" b1="13 CRAWF" b2="138 KV" b3="1322 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B714 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B718 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="1322" b2="138 KV" b3="1322 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="115 BEDF" b2="138 KV" b3="1322 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="104 FORD" b2="138 KV" b3="1322 5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="33 HAYFO" b2="138 KV" b3="71L1322M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="33 HAYFO" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="63 SAWYE" b2="138 KV" b3="1322 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="63 SAWYE" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="63 SAWYE" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26750</SeqNum>
    <Name>L138.Bedford-Ford-Hayford-Sawyer.1324</Name>
    <LastEdit Timestamp="2026-03-30T18:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="104 FORD" b2="138 KV" b3="1324 5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="104 FORD" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="115 BEDF" b2="138 KV" b3="1324 4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="138 KV" b3="L1324 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="1324" b2="138 KV" b3="1324 3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="33 HAYFO" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="63 SAWYE" b2="138 KV" b3="1324 2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="63 SAWYE" b2="138 KV" b3="2407CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="63 SAWYE" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26760</SeqNum>
    <Name>L138.13Crawford-63Sawyer.1324</Name>
    <LastEdit Timestamp="2025-06-24T08:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="63 SAWYE" b2="138 KV" b3="1324 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B726 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B728 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="63 SAWYE" b2="138 KV" b3="2407CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="63 SAWYE" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26770</SeqNum>
    <Name>L138.13Crawford-45Jefferson + Jefferson.TR76</Name>
    <LastEdit Timestamp="2025-10-28T11:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="13 CRAWF" b2="138 KV" b3="1326" />
      <ContingencyEquipment Action="S" Type="SD" b1="13 CRAWF" b2="138 KV" b3="1326 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B713 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B715 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="69 KV" b3="BT611 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="69 KV" b3="BT613 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="45 JEFFE" b2="138 KV" b3="TR76 69" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26780</SeqNum>
    <Name>L138.Powerton-TowerLine.L1404 Tie Line</Name>
    <LastEdit Timestamp="2025-08-13T13:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="138 KV" b3="L1404_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWRL" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWRL" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="L" Type="LN" b1="3 POWERT" b2="138 KV" b3="POW-TWRL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26790</SeqNum>
    <Name>L138.Waukegan-1603-RoundLake.1603</Name>
    <LastEdit Timestamp="2026-04-01T13:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="16 WAUKE" b2="138 KV" b3="1603 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="138 KV" b3="L1603 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="1603" b2="138 KV" b3="1603 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="42 ROUND" b2="138 KV" b3="1603 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="1603" b2="138 KV" b3="1603 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="1603" b2="138 KV" b3="1603 5" />
      <ContingencyEquipment Action="S" Type="SD" b1="1603" b2="138 KV" b3="1603 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="1603" b2="138 KV" b3="1603 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="230 ANTI" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="230 ANTI" b2="138 KV" b3="L1603 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="251 ROUN" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="251 ROUN" b2="138 KV" b3="TR72" />
      <ContingencyEquipment Action="OP" Type="CB" b1="251 ROUN" b2="12.5 KV" b3="TR72 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="294 GURN" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="294 GURN" b2="138 KV" b3="L1603 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="42 ROUND" b2="138 KV" b3="1603 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26800</SeqNum>
    <Name>L138.16Waukegan-1604-154LibertyVille-AbbotLab.1604</Name>
    <LastEdit Timestamp="2025-10-28T11:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="154 LIBE" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="138 KV" b3="L1604 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="16 WAUKE" b2="138 KV" b3="1604 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="154 LIBE" b2="138 KV" b3="1604 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="1604" b2="138 KV" b3="1604 5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="A429" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="A429" b2="138 KV" b3="L1604 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26810</SeqNum>
    <Name>L138.Waukegan-1605-Highland.1605</Name>
    <LastEdit Timestamp="2024-10-03T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="138 KV" b3="L1605 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="16 WAUKE" b2="138 KV" b3="1605 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="1605" b2="138 KV" b3="1605 10" />
      <ContingencyEquipment Action="S" Type="SD" b1="1605" b2="138 KV" b3="1605 11" />
      <ContingencyEquipment Action="S" Type="SD" b1="1605" b2="138 KV" b3="1605 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="1605" b2="138 KV" b3="1605 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="1605" b2="138 KV" b3="1605 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="1605" b2="138 KV" b3="1605 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="48 HIGHL" b2="138 KV" b3="1605 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="1605" b2="138 KV" b3="1605 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="1605" b2="138 KV" b3="1605 8" />
      <ContingencyEquipment Action="L" Type="LN" b1="1605" b2="138 KV" b3="1605 9" />
      <ContingencyEquipment Action="L" Type="LN" b1="1605" b2="138 KV" b3="1605 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="1605" b2="138 KV" b3="1605 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="1605" b2="138 KV" b3="1605 Z3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="204 OLD" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="204 OLD" b2="138 KV" b3="L1605 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="222 BLUF" b2="138 KV" b3="BT1-2CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="222 BLUF" b2="138 KV" b3="L1605 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="234 LAKE" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="234 LAKE" b2="138 KV" b3="L1605 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="48 HIGHL" b2="138 KV" b3="L1605" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="69 N CHI" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="69 N CHI" b2="138 KV" b3="L1605 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="A431-1" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="A431-1" b2="138 KV" b3="L1605 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="A431-2" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="A431-2" b2="138 KV" b3="L1605 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="A450" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="A450" b2="138 KV" b3="L1605 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26820</SeqNum>
    <Name>L138.Waukegan-1606-Highland-OldElm-LakeBluff.1606</Name>
    <LastEdit Timestamp="2024-12-09T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="138 KV" b3="L1606 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="16 WAUKE" b2="138 KV" b3="1606 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="1606" b2="138 KV" b3="1606 10" />
      <ContingencyEquipment Action="S" Type="SD" b1="1606" b2="138 KV" b3="1606 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="1606" b2="138 KV" b3="1606 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="1606" b2="138 KV" b3="1606 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="1606" b2="138 KV" b3="1606 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="48 HIGHL" b2="138 KV" b3="1606 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="1606" b2="138 KV" b3="1606 7" />
      <ContingencyEquipment Action="S" Type="SD" b1="1606" b2="138 KV" b3="1606 8" />
      <ContingencyEquipment Action="L" Type="LN" b1="1606" b2="138 KV" b3="1606 9" />
      <ContingencyEquipment Action="L" Type="LN" b1="1606" b2="138 KV" b3="1606 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="1606" b2="138 KV" b3="1606 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="1606" b2="138 KV" b3="1606 Z3" />
      <ContingencyEquipment Action="L" Type="LN" b1="1606" b2="138 KV" b3="1606 Z4" />
      <ContingencyEquipment Action="L" Type="LN" b1="1606" b2="138 KV" b3="1606 Z5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="204 OLD" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="204 OLD" b2="138 KV" b3="L1606 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="222 BLUF" b2="138 KV" b3="BT1-2CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="222 BLUF" b2="138 KV" b3="L1606 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="234 LAKE" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="234 LAKE" b2="138 KV" b3="L1606 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="48 HIGHL" b2="138 KV" b3="L1606" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="69 N CHI" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="69 N CHI" b2="138 KV" b3="L1606 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="A431-1" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="A431-1" b2="138 KV" b3="L1606 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="A431-2" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="A431-2" b2="138 KV" b3="L1606 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="A450" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="A450" b2="138 KV" b3="L1606 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26830</SeqNum>
    <Name>L138.Waukegan-1607-RoundLake-Gurnee-Antioch.1607</Name>
    <LastEdit Timestamp="2024-11-20T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="16 WAUKE" b2="138 KV" b3="1607 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="138 KV" b3="L1607 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="42 ROUND" b2="138 KV" b3="1607 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="294 GURN" b2="138 KV" b3="1607 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="1607" b2="138 KV" b3="1607 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="1607" b2="138 KV" b3="1607 5" />
      <ContingencyEquipment Action="S" Type="SD" b1="1607" b2="138 KV" b3="1607 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="1607" b2="138 KV" b3="1607 Z2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="230 ANTI" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="230 ANTI" b2="138 KV" b3="L1607 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="251 ROUN" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="251 ROUN" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="251 ROUN" b2="12.5 KV" b3="TR71 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="294 GURN" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="294 GURN" b2="138 KV" b3="L1607 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="42 ROUND" b2="138 KV" b3="1607 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="42 ROUND" b2="138 KV" b3="1607 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="42 ROUND" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="42 ROUND" b2="138 KV" b3="L1607 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26840</SeqNum>
    <Name>L138.Waukegan-1608-LibertyVille.1608</Name>
    <LastEdit Timestamp="2025-10-28T12:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="1608" b2="138 KV" b3="1608 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="138 KV" b3="L1608 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="16 WAUKE" b2="138 KV" b3="1608 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="138 KV" b3="L1608 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="1608" b2="138 KV" b3="1608 4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="A429" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="A429" b2="138 KV" b3="L1608 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26850</SeqNum>
    <Name>L138.Waukegan-Zion.1609</Name>
    <LastEdit Timestamp="2026-05-08T13:44:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="16 WAUKE" b2="138 KV" b3="1609" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="138 KV" b3="L1609 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="282 ZION" b2="138 KV" b3="BT" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="282 ZION" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="282 ZION" b2="138 KV" b3="L1609 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26860</SeqNum>
    <Name>L138.WillCounty-1802-J310ArgonneLab.1802</Name>
    <LastEdit Timestamp="2025-11-10T14:20:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="18 WILL" b2="138 KV" b3="1802 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="18 WILL" b2="138 KV" b3="L1802 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="J310" b2="138 KV" b3="1802_2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="J307" b2="138 KV" b3="0211CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="1802" b2="138 KV" b3="1802 4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="J310" b2="138 KV" b3="5-6CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="J310" b2="138 KV" b3="5-8CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26870</SeqNum>
    <Name>L138.Lisle-Woodridge-Bolingbrook.10314</Name>
    <LastEdit Timestamp="2026-02-10T09:48:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="103 LISL" b2="138 KV" b3="10314 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="138 KV" b3="L10314CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="103 LISL" b2="138 KV" b3="TR79 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="34.5 KV" b3="TR79 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="10314" b2="138 KV" b3="10314 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="10314" b2="138 KV" b3="10314 5" />
      <ContingencyEquipment Action="S" Type="SD" b1="10314" b2="138 KV" b3="10314 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="10314" b2="138 KV" b3="10314 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="10314" b2="138 KV" b3="10314 8" />
      <ContingencyEquipment Action="L" Type="LN" b1="10314" b2="138 KV" b3="10314Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="10314" b2="138 KV" b3="10314Z3" />
      <ContingencyEquipment Action="L" Type="LN" b1="10314" b2="138 KV" b3="10314Z4" />
      <ContingencyEquipment Action="L" Type="LN" b1="1803" b2="138 KV" b3="180-1031" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1803" b2="138 KV" b3="1803-314" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="1804" b2="138 KV" b3="0410CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="103 LISL" b2="138 KV" b3="10314 1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="559 WOOD" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="561 BOLN" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="561 BOLN" b2="138 KV" b3="DUM2" />
      <ContingencyEquipment Action="L" Type="LN" b1="559 WOOD" b2="138 KV" b3="10314 4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="580 DOWN" b2="138 KV" b3="10314CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="580 DOWN" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="W603" b2="138 KV" b3="BT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W603" b2="138 KV" b3="L10314CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W604" b2="138 KV" b3="130060CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26880</SeqNum>
    <Name>L138.WillCo-1804-WolfsCrossing.1804</Name>
    <LastEdit Timestamp="2025-06-18T13:13:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="143 WOLF" b2="138 KV" b3="L1804 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="18 WILL" b2="138 KV" b3="1804 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="18 WILL" b2="138 KV" b3="L1804 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="18 WILL" b2="138 KV" b3="L1804TBD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="1804" b2="138 KV" b3="0410CS" />
      <ContingencyEquipment Action="S" Type="SD" b1="1804" b2="138 KV" b3="1804 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="1804" b2="138 KV" b3="1804 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="1804" b2="138 KV" b3="1804 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="1804" b2="138 KV" b3="1804 7" />
      <ContingencyEquipment Action="S" Type="SD" b1="1804" b2="138 KV" b3="1804 8" />
      <ContingencyEquipment Action="L" Type="LN" b1="1804" b2="138 KV" b3="1804 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="1804" b2="138 KV" b3="1804 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="1804" b2="138 KV" b3="1804 Z3" />
      <ContingencyEquipment Action="L" Type="LN" b1="1804" b2="138 KV" b3="1804 Z4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="454 PLAI" b2="138 KV" b3="0437CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="454 PLAI" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="499 WEBE" b2="138 KV" b3="BT1-2 M" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="499 WEBE" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="W601" b2="138 KV" b3="BT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W601" b2="138 KV" b3="L1804 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="W602" b2="138 KV" b3="BT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W602" b2="138 KV" b3="L1804 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26890</SeqNum>
    <Name>L138.18_WillCo-J310.1807</Name>
    <LastEdit Timestamp="2024-06-12T14:00:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="18 WILL" b2="138 KV" b3="1807 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="18 WILL" b2="138 KV" b3="L1807 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="18 WILL" b2="138 KV" b3="L1807TBD" />
      <ContingencyEquipment Action="L" Type="LN" b1="J310" b2="138 KV" b3="1807 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="1807" b2="138 KV" b3="1807 3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="J307" b2="138 KV" b3="0211CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="J307" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="J310" b2="138 KV" b3="L1807 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26900</SeqNum>
    <Name>L138.WillCo-GoodingsGrove.1808</Name>
    <LastEdit Timestamp="2024-08-19T15:13:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="116 GOOD" b2="138 KV" b3="1808 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="138 KV" b3="L1808 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="18 WILL" b2="138 KV" b3="1808 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="18 WILL" b2="138 KV" b3="L1808 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="1808" b2="138 KV" b3="1808 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="1808" b2="138 KV" b3="1808 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="1808" b2="138 KV" b3="1808 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="1808" b2="138 KV" b3="1808 Z1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="416 BELL" b2="138 KV" b3="0843CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="416 BELL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="480 VET" b2="138 KV" b3="1808" />
      <ContingencyEquipment Action="L" Type="LN" b1="1808" b2="138 KV" b3="1808 6" />
      <ContingencyEquipment Action="CL" Type="CB" b1="480 VET" b2="138 KV" b3="2-3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="487 ARCH" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26910</SeqNum>
    <Name>L138.WillCounty-Romeoville-Normantown.1809</Name>
    <LastEdit Timestamp="2024-11-27T11:13:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="18 WILL" b2="138 KV" b3="1809 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="18 WILL" b2="138 KV" b3="L1809 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="18 WILL" b2="138 KV" b3="L1809TBD" />
      <ContingencyEquipment Action="L" Type="LN" b1="1809" b2="138 KV" b3="1809 Z2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="411 ROME" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="1809" b2="138 KV" b3="1809_Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="525 NORM" b2="138 KV" b3="L1809" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26920</SeqNum>
    <Name>L138.WillCo-1811-Archer-BellRd-GoodingsGrove.1811</Name>
    <LastEdit Timestamp="2025-01-21T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="116 GOOD" b2="138 KV" b3="1811 4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="138 KV" b3="L1811 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="18 WILL" b2="138 KV" b3="1811 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="18 WILL" b2="138 KV" b3="L1811 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="18 WILL" b2="138 KV" b3="L1811TBD" />
      <ContingencyEquipment Action="S" Type="SD" b1="1811" b2="138 KV" b3="1811 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="1811" b2="138 KV" b3="1811 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="1811" b2="138 KV" b3="1811 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="1811" b2="138 KV" b3="1811 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="1811" b2="138 KV" b3="1811 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="1811" b2="138 KV" b3="1811 8" />
      <ContingencyEquipment Action="S" Type="SD" b1="1811" b2="138 KV" b3="1811 9" />
      <ContingencyEquipment Action="L" Type="LN" b1="1811" b2="138 KV" b3="1811 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="1811" b2="138 KV" b3="1811 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="1811" b2="138 KV" b3="1811 Z3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="416 BELL" b2="138 KV" b3="1159CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="416 BELL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="480 VET" b2="138 KV" b3="1811" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="480 VET" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="487 ARCH" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="J332-1" b2="138 KV" b3="BT0670LS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="J332-1" b2="138 KV" b3="BT1140LS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="J332-1" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="J332-1" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="J332-2" b2="138 KV" b3="1134CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="J332-2" b2="138 KV" b3="BT0630D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26930</SeqNum>
    <Name>L138.36Madison-90Dekoven.3610 G SPOG 2-27</Name>
    <LastEdit Timestamp="2024-12-05T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="36 MADIS" b2="138 KV" b3="3610" />
      <ContingencyEquipment Action="OP" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="90 DEKOV" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="90 DEKOV" b2="138 KV" b3="BT3-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26950</SeqNum>
    <Name>L138.36Madison-90Dekoven.3611 G SPOG 2-27</Name>
    <LastEdit Timestamp="2024-12-05T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="36 MADIS" b2="138 KV" b3="3611" />
      <ContingencyEquipment Action="CL" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="90 DEKOV" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="90 DEKOV" b2="138 KV" b3="BT7-8 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26970</SeqNum>
    <Name>L138.37Natom-31Gale-39Port-32Hanson.3701</Name>
    <LastEdit Timestamp="2024-06-12T13:59:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="31 GALEW" b2="138 KV" b3="3701Y" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="31 GALEW" b2="138 KV" b3="TR1 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="32 HANSO" b2="138 KV" b3="3701X 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="32 HANSO" b2="138 KV" b3="TR1 12" />
      <ContingencyEquipment Action="S" Type="SD" b1="37 NATOM" b2="138 KV" b3="3701 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="37 NATOM" b2="138 KV" b3="3701X 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT726 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT728 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="3701" b2="138 KV" b3="3701X 1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="39 PORTA" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="39 PORTA" b2="138 KV" b3="TR77 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26980</SeqNum>
    <Name>L138.Natom-3702-Galewood-Hanson-Portage.3702</Name>
    <LastEdit Timestamp="2025-03-05T16:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="31 GALEW" b2="138 KV" b3="3702Y" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="31 GALEW" b2="138 KV" b3="TR2 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="32 HANSO" b2="138 KV" b3="3702X 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="32 HANSO" b2="138 KV" b3="TR2 12" />
      <ContingencyEquipment Action="S" Type="SD" b1="37 NATOM" b2="138 KV" b3="3702 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="37 NATOM" b2="138 KV" b3="3702X 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT45 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT89 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="3702" b2="138 KV" b3="3702X 1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="39 PORTA" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>26990</SeqNum>
    <Name>L138.37Natom-31Gale-39Port-32Hanson.3703</Name>
    <LastEdit Timestamp="2024-06-12T13:59:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="31 GALEW" b2="138 KV" b3="3703Y" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="31 GALEW" b2="138 KV" b3="TR3 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="32 HANSO" b2="138 KV" b3="3703X 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="32 HANSO" b2="138 KV" b3="TR3 12" />
      <ContingencyEquipment Action="S" Type="SD" b1="37 NATOM" b2="138 KV" b3="3703 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="37 NATOM" b2="138 KV" b3="3703X 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT725 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT727 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="3703" b2="138 KV" b3="3703X 1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="39 PORTA" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="39 PORTA" b2="138 KV" b3="TR75 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27000</SeqNum>
    <Name>L138.37Natom-31Gale-39Port-32Hanson.3704</Name>
    <LastEdit Timestamp="2024-06-12T14:00:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="31 GALEW" b2="138 KV" b3="3704Y" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="31 GALEW" b2="138 KV" b3="TR4 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="32 HANSO" b2="138 KV" b3="3704X 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="32 HANSO" b2="138 KV" b3="TR4 12" />
      <ContingencyEquipment Action="S" Type="SD" b1="37 NATOM" b2="138 KV" b3="3704 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="37 NATOM" b2="138 KV" b3="3704X 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT12 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT2121CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT91 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="3704" b2="138 KV" b3="3704X 1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="39 PORTA" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="39 PORTA" b2="138 KV" b3="TR76 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27030</SeqNum>
    <Name>L138.37Natoma-648Norridge.3707</Name>
    <LastEdit Timestamp="2025-06-19T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="37 NATOM" b2="138 KV" b3="3707" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT34 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT45 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="648 NORR" b2="138 KV" b3="BT716 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="648 NORR" b2="138 KV" b3="BT723 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="648 NORR" b2="138 KV" b3="BT756 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27040</SeqNum>
    <Name>L138.OakPark-Natoma.3709</Name>
    <LastEdit Timestamp="2026-04-01T13:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="37 NATOM" b2="138 KV" b3="3709" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT721 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT725 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="505 OAK" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="505 OAK" b2="138 KV" b3="BT4-5 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="505 OAK" b2="138 KV" b3="BT5-6 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27050</SeqNum>
    <Name>L138.Natoma-FranklinPark.3710</Name>
    <LastEdit Timestamp="2025-02-25T19:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="37 NATOM" b2="138 KV" b3="3710" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT12 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT34 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="37 NATOM" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="138 KV" b3="BT3-5 CB" />
      <ContingencyEquipment Action="P" Type="XF" b1="78 FRANK" b2="138 KV" b3="P3710" />
      <ContingencyEquipment Action="X" Type="XF" b1="78 FRANK" b2="138 KV" b3="P3710T38" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="78 FRANK" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="78 FRANK" b2="34.5 KV" b3="TR78" />
      <ContingencyEquipment Action="X" Type="XF" b1="78 FRANK" b2="138 KV" b3="TR78 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="34.5 KV" b3="TR78 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="78 FRANK" b2="138 KV" b3="Z3710T38" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27060</SeqNum>
    <Name>L138.Diversey-Clybourn.4013 G (SPOG 2-22)</Name>
    <LastEdit Timestamp="2025-03-31T00:12:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="54 CLYBO" b2="138 KV" b3="4013" />
      <ContingencyEquipment Action="CL" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT2-11CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="54 CLYBO" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="54 CLYBO" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27080</SeqNum>
    <Name>L138.Crosby-Diversey.4018</Name>
    <LastEdit Timestamp="2024-09-19T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="82 CROSB" b2="138 KV" b3="4018" />
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT6-11CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1018CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27090</SeqNum>
    <Name>L138.RoundLake-4202-SilverLake.4202</Name>
    <LastEdit Timestamp="2026-04-01T13:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="138 SILV" b2="138 KV" b3="4202 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="138 KV" b3="L4202 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="4202" b2="138 KV" b3="4202 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="228 WILS" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="228 WILS" b2="138 KV" b3="L4202 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="42 ROUND" b2="138 KV" b3="4202 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="42 ROUND" b2="138 KV" b3="4202 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27100</SeqNum>
    <Name>L138.RoundLake-4203-SilverLake.4203</Name>
    <LastEdit Timestamp="2025-06-11T16:27:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="138 SILV" b2="138 KV" b3="4203 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="138 KV" b3="L4203 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="228 WILS" b2="138 KV" b3="4203 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="228 WILS" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="228 WILS" b2="138 KV" b3="L4203 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="42 ROUND" b2="138 KV" b3="4203 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="42 ROUND" b2="138 KV" b3="4203 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="42 ROUND" b2="138 KV" b3="4203_Z2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="42 ROUND" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="42 ROUND" b2="138 KV" b3="L4203 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27110</SeqNum>
    <Name>L138.Jefferson-Fisk.4522</Name>
    <LastEdit Timestamp="2026-04-01T13:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="11 FISK" b2="138 KV" b3="4522 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT1516CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT3-16CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT9-16CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT1-12CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT1-2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27120</SeqNum>
    <Name>L138.Jefferson-Fisk.4523</Name>
    <LastEdit Timestamp="2026-04-01T13:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="1-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="11 FISK" b2="138 KV" b3="4523" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT7-8 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27140</SeqNum>
    <Name>L138.Itasca-Tonne.10117</Name>
    <LastEdit Timestamp="2025-10-28T12:07:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="101 ITAS" b2="138 KV" b3="10117" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="L10117CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="207 TONN" b2="138 KV" b3="L10117CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27160</SeqNum>
    <Name>L138.Itasca-Tonne.10118</Name>
    <LastEdit Timestamp="2025-10-28T12:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="101 ITAS" b2="138 KV" b3="10118" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="L10118CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="207 TONN" b2="138 KV" b3="L10118CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27170</SeqNum>
    <Name>L138.Desplains-Higgins.4607</Name>
    <LastEdit Timestamp="2026-03-30T18:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="71 HIGGI" b2="138 KV" b3="4607" />
      <ContingencyEquipment Action="S" Type="SD" b1="46 DESPL" b2="138 KV" b3="I4607" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L4607 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="71 HIGGI" b2="138 KV" b3="BT716 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="71 HIGGI" b2="138 KV" b3="BT723 M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="71 HIGGI" b2="138 KV" b3="BT756 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27180</SeqNum>
    <Name>L138.Desplains-4608-Howard.L4608</Name>
    <LastEdit Timestamp="2025-03-27T17:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="198 DESP" b2="138 KV" b3="4608 2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="198 DESP" b2="138 KV" b3="L4608 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="215 HOWA" b2="138 KV" b3="4608 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="215 HOWA" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="46 DESPL" b2="138 KV" b3="4608 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L4608 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27190</SeqNum>
    <Name>L138.Desplains-GolfMill.4610</Name>
    <LastEdit Timestamp="2025-04-28T15:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="172 GOLF" b2="138 KV" b3="4610" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="L4610 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L4610 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27200</SeqNum>
    <Name>L138.Desplains-GolfMill.4611</Name>
    <LastEdit Timestamp="2025-04-28T15:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="172 GOLF" b2="138 KV" b3="4611" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="L4611 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L4611 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27210</SeqNum>
    <Name>L138.51McCook-5103-115BedfordPark.5103</Name>
    <LastEdit Timestamp="2025-11-14T13:27:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="115 BEDF" b2="138 KV" b3="5103 7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="138 KV" b3="L5103 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="51 MC CO" b2="138 KV" b3="5103 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5103 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="5103" b2="138 KV" b3="5103 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="5103" b2="138 KV" b3="5103 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="5103" b2="138 KV" b3="5103 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="5103" b2="138 KV" b3="5103 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="5103" b2="138 KV" b3="5103 8" />
      <ContingencyEquipment Action="L" Type="LN" b1="5103" b2="138 KV" b3="5103 9" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="550 CLEA" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="550 CLEA" b2="138 KV" b3="L5103 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="593 WILL" b2="138 KV" b3="L59306" />
      <ContingencyEquipment Action="OP" Type="CB" b1="D438" b2="138 KV" b3="138-20" />
      <ContingencyEquipment Action="CL" Type="CB" b1="D438" b2="138 KV" b3="138-30" />
      <ContingencyEquipment Action="L" Type="LN" b1="D438" b2="138 KV" b3="5103 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="D775" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27220</SeqNum>
    <Name>L138.51McCook-5104-J310-115BedfordPark.5104</Name>
    <LastEdit Timestamp="2024-12-10T15:41:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="115 BEDF" b2="138 KV" b3="5104 8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="138 KV" b3="L5104 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="115 BEDF" b2="138 KV" b3="L5104TBD" />
      <ContingencyEquipment Action="L" Type="LN" b1="5104" b2="138 KV" b3="5104 5" />
      <ContingencyEquipment Action="CL" Type="CB" b1="136 BURR" b2="138 KV" b3="BT2-3CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="136 BURR" b2="138 KV" b3="L5104CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="51 MC CO" b2="138 KV" b3="5104 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5104 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="5104" b2="138 KV" b3="5104 10" />
      <ContingencyEquipment Action="L" Type="LN" b1="5104" b2="138 KV" b3="5104 11" />
      <ContingencyEquipment Action="S" Type="SD" b1="5104" b2="138 KV" b3="5104 12" />
      <ContingencyEquipment Action="S" Type="SD" b1="5104" b2="138 KV" b3="5104 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="5104" b2="138 KV" b3="5104 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="J310" b2="138 KV" b3="5104 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="5104" b2="138 KV" b3="5104 6" />
      <ContingencyEquipment Action="S" Type="SD" b1="5104" b2="138 KV" b3="5104 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="5104" b2="138 KV" b3="5104 9" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="550 CLEA" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="550 CLEA" b2="138 KV" b3="L5104 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="593 WILL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="593 WILL" b2="138 KV" b3="L5104 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="D438" b2="138 KV" b3="138-10" />
      <ContingencyEquipment Action="CL" Type="CB" b1="D438" b2="138 KV" b3="138-30" />
      <ContingencyEquipment Action="L" Type="LN" b1="D438" b2="138 KV" b3="5104 13" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="D775" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="J310" b2="138 KV" b3="L5104 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27230</SeqNum>
    <Name>L138.51McCook-192Ridge.5105 (SPOG 2-25)</Name>
    <LastEdit Timestamp="2024-06-12T12:08:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="51 MC CO" b2="138 KV" b3="5105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="192 RIDG" b2="138 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="192 RIDG" b2="138 KV" b3="BT4-14CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="192 RIDG" b2="138 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5105 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27260</SeqNum>
    <Name>L138.Rideland-McCook.5107</Name>
    <LastEdit Timestamp="2026-04-03T10:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="51 MC CO" b2="138 KV" b3="5107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="192 RIDG" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="192 RIDG" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5107 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27270</SeqNum>
    <Name>L138.McCook-Bellwood-Lagrange.5117</Name>
    <LastEdit Timestamp="2025-11-25T16:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="5117" b2="138 KV" b3="5117 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="134 LAGR" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="134 LAGR" b2="138 KV" b3="L5117 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="51 MC CO" b2="138 KV" b3="5117 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5117 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="64 BELLW" b2="138 KV" b3="5117 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="138 KV" b3="BT11-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="138 KV" b3="BT1115CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="64 BELLW" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="64 BELLW" b2="138 KV" b3="TR79 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="34.5 KV" b3="TR79 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27280</SeqNum>
    <Name>L138.51McCook-5118-134Lagrange-64Bellwood.5118</Name>
    <LastEdit Timestamp="2025-11-25T16:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="5118" b2="138 KV" b3="5118 6" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="134 LAGR" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="134 LAGR" b2="138 KV" b3="L5118 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="51 MC CO" b2="138 KV" b3="5118 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5118 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="64 BELLW" b2="138 KV" b3="5118 4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="138 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="138 KV" b3="3-5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="64 BELLW" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="64 BELLW" b2="138 KV" b3="TR77 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="34.5 KV" b3="TR77 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27290</SeqNum>
    <Name>L138.58Grand-36Madison.5810 G SPOG 2-27</Name>
    <LastEdit Timestamp="2024-12-05T16:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="58 GRAND" b2="138 KV" b3="5810" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1119CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1213CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27310</SeqNum>
    <Name>L138.58Grand-36Madison.5811 G SPOG 2-27</Name>
    <LastEdit Timestamp="2024-12-05T16:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="58 GRAND" b2="138 KV" b3="5811" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1415CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1516CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1617CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27330</SeqNum>
    <Name>L138.58Grand-148W LO.5826 G SPOG 2-27</Name>
    <LastEdit Timestamp="2024-12-05T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="148 W LO" b2="138 KV" b3="5826" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1213CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1617CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1718CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27350</SeqNum>
    <Name>L138.58Grand-148W LO.5828 G SPOG 2-27</Name>
    <LastEdit Timestamp="2024-12-05T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="36 MADIS" b2="138 KV" b3="BT5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="148 W LO" b2="138 KV" b3="5828" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1213CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1314CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1516CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1617CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27380</SeqNum>
    <Name>L138.Streator-6102-Kickapoo-Marseile</Name>
    <LastEdit Timestamp="2024-10-21T07:42:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="0108" b2="138 KV" b3="0820 S" />
      <ContingencyEquipment Action="L" Type="LN" b1="6102" b2="138 KV" b3="6102 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="105 KICK" b2="138 KV" b3="6102 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="105 KICK" b2="138 KV" b3="L6102CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="6102" b2="138 KV" b3="6102 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="61 STREA" b2="138 KV" b3="L6102 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="6102" b2="138 KV" b3="6102 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="6102" b2="138 KV" b3="6102 4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSEILE" b2="138 KV" b3="B039" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27390</SeqNum>
    <Name>L138.KickapooCreek-Lasalle.0112</Name>
    <LastEdit Timestamp="2025-03-31T12:18:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="1 LASALL" b2="138 KV" b3="0112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="138 KV" b3="0112 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="105 KICK" b2="138 KV" b3="L0112CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27400</SeqNum>
    <Name>L138.EFrankfort-6603-Matteson-CCHills-Mokena.6603</Name>
    <LastEdit Timestamp="2025-03-05T16:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="127 MATT" b2="138 KV" b3="6603 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="127 MATT" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="127 MATT" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="127 MATT" b2="138 KV" b3="TR77 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="435 CC H" b2="138 KV" b3="6603 5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="435 CC H" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="435 CC H" b2="138 KV" b3="L6603 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="451 MOKE" b2="138 KV" b3="6603 4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="451 MOKE" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="451 MOKE" b2="138 KV" b3="L6603 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="66 E FRN" b2="138 KV" b3="6603 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="138 KV" b3="L6603 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="6603" b2="138 KV" b3="6603 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27410</SeqNum>
    <Name>L138.East Frankfort-6604-CC Hills.6604</Name>
    <LastEdit Timestamp="2026-04-03T09:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="127 MATT" b2="138 KV" b3="6604 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="127 MATT" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="435 CC H" b2="138 KV" b3="6604 5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="435 CC H" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="435 CC H" b2="138 KV" b3="L6604 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="451 MOKE" b2="138 KV" b3="6604 4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="451 MOKE" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="451 MOKE" b2="138 KV" b3="L6604 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="66 E FRN" b2="138 KV" b3="6604 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="138 KV" b3="L6604 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="6604" b2="138 KV" b3="6604 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27420</SeqNum>
    <Name>L138.EFrankFort-6605-UniversityPk + University.CTs</Name>
    <LastEdit Timestamp="2026-05-08T13:34:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="453 WOOD" b2="138 KV" b3="6605 2" />
      <ContingencyEquipment Action="CL" Type="CB" b1="453 WOOD" b2="138 KV" b3="BT2-3CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="453 WOOD" b2="138 KV" b3="L6605 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="66 E FRN" b2="138 KV" b3="6605 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="138 KV" b3="L6605 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="6605" b2="138 KV" b3="6605 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="946 UNIV" b2="138 KV" b3="L6605 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="946 UNIV" b2="138 KV" b3="TR31-1A" />
      <ContingencyEquipment Action="X" Type="XF" b1="946 UNIV" b2="138 KV" b3="TR32-1A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="946 UNIV" b2="13.5 KV" b3="UP31-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="946 UNIV" b2="13.5 KV" b3="UP31-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="946 UNIV" b2="13.5 KV" b3="UP32-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="946 UNIV" b2="13.5 KV" b3="UP32-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27430</SeqNum>
    <Name>L138.EFrankfort-6606-UniversityPk.6606 + CTs</Name>
    <LastEdit Timestamp="2026-05-13T14:01:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="453 WOOD" b2="138 KV" b3="6606 2" />
      <ContingencyEquipment Action="CL" Type="CB" b1="453 WOOD" b2="138 KV" b3="BT2-3CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="453 WOOD" b2="138 KV" b3="L6606 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="66 E FRN" b2="138 KV" b3="6606 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="138 KV" b3="L6606 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="6606" b2="138 KV" b3="6606 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="946 UNIV" b2="138 KV" b3="L6606 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="946 UNIV" b2="138 KV" b3="TR33-1A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="946 UNIV" b2="13.5 KV" b3="UP33-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="946 UNIV" b2="13.5 KV" b3="UP33-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27440</SeqNum>
    <Name>L138.ChicagoHeights-7305-Bloom-Glenwood.7305</Name>
    <LastEdit Timestamp="2026-02-10T10:55:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="179 BLOO" b2="138 KV" b3="7305 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="179 BLOO" b2="138 KV" b3="L7305 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="452 GLEN" b2="138 KV" b3="0536" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="452 GLEN" b2="138 KV" b3="0549CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="7305" b2="138 KV" b3="7305_4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="452 GLEN" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="73 CHI H" b2="138 KV" b3="7305 7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="73 CHI H" b2="138 KV" b3="L7305 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="7305" b2="138 KV" b3="7305 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="7305" b2="138 KV" b3="7305 6" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="F375" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="F375" b2="138 KV" b3="L7305 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27450</SeqNum>
    <Name>L138.ChicagoHeights-7306-Glenwood-Bloom.7306</Name>
    <LastEdit Timestamp="2025-10-28T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="179 BLOO" b2="138 KV" b3="7306 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="179 BLOO" b2="138 KV" b3="L7306 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="452 GLEN" b2="138 KV" b3="0651CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="7306" b2="138 KV" b3="7306_5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="452 GLEN" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="73 CHI H" b2="138 KV" b3="7306 11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="73 CHI H" b2="138 KV" b3="L7306 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="7306" b2="138 KV" b3="7306 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="7306" b2="138 KV" b3="7306 7" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="F375" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="F375" b2="138 KV" b3="L7306 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27460</SeqNum>
    <Name>L138.73ChicagoHeights-7307-177Burnham.7307</Name>
    <LastEdit Timestamp="2024-12-10T14:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="177 BURN" b2="138 KV" b3="7307 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="138 KV" b3="L7307 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="7307" b2="138 KV" b3="7307 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="446 LANS" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="447 SANR" b2="138 KV" b3="7307 Z3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="447 SANR" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="7307" b2="138 KV" b3="7307 Z2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="458 GREE" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="73 CHI H" b2="138 KV" b3="7307 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="73 CHI H" b2="138 KV" b3="L7307 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="7307" b2="138 KV" b3="7307 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="7307" b2="138 KV" b3="7307 4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27470</SeqNum>
    <Name>L138.Keemin(MISO/Ameren)-Kewanee.7411</Name>
    <LastEdit Timestamp="2026-04-03T10:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KEEMIN" b2="138 KV" b3="KEE-KEWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="74 KEWAN" b2="138 KV" b3="L7411 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEEMIN" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEEMIN" b2="138 KV" b3="H5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27480</SeqNum>
    <Name>L138.74Kewanee-981Crescent.7413</Name>
    <LastEdit Timestamp="2024-06-12T14:19:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="981 CRES" b2="138 KV" b3="7413" />
      <ContingencyEquipment Action="OP" Type="CB" b1="74 KEWAN" b2="138 KV" b3="L7413 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="981 CRES" b2="138 KV" b3="L7413 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27490</SeqNum>
    <Name>L138.Corbin-CrescentRidge.98105</Name>
    <LastEdit Timestamp="2024-08-19T15:21:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="981 CRES" b2="138 KV" b3="L98105CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRBN" b2="138 KV" b3="CRB-CRES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRBN" b2="138 KV" b3="H31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRBN" b2="138 KV" b3="H33" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27500</SeqNum>
    <Name>L138.74Kewanee-Edwards.7423</Name>
    <LastEdit Timestamp="2024-06-12T14:26:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="74 KEWAN" b2="138 KV" b3="7423" />
      <ContingencyEquipment Action="OP" Type="CB" b1="74 KEWAN" b2="138 KV" b3="L7423 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDWARDS3" b2="138 KV" b3="H15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDWARDS3" b2="138 KV" b3="H17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27510</SeqNum>
    <Name>L138.76BlueIsland-7611-43Wildwood.7611</Name>
    <LastEdit Timestamp="2024-12-10T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="118 WALL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="118 WALL" b2="138 KV" b3="L7611 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="43 WILDW" b2="138 KV" b3="BT1-4 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="465 S HO" b2="138 KV" b3="1119CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="465 S HO" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="76 BLUE" b2="138 KV" b3="L7611 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="76 BLUE" b2="138 KV" b3="7611 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="7611" b2="138 KV" b3="7611 10" />
      <ContingencyEquipment Action="S" Type="SD" b1="7611" b2="138 KV" b3="7611 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="7611" b2="138 KV" b3="7611 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="7611" b2="138 KV" b3="7611 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="43 WILDW" b2="138 KV" b3="7611 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="7611" b2="138 KV" b3="7611 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="118 WALL" b2="138 KV" b3="7611 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="7611" b2="138 KV" b3="7611 8" />
      <ContingencyEquipment Action="L" Type="LN" b1="7611" b2="138 KV" b3="7611 9" />
      <ContingencyEquipment Action="S" Type="SD" b1="7611" b2="138 KV" b3="7611 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="89 BEVER" b2="138 KV" b3="BT2-3 M" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="89 BEVER" b2="138 KV" b3="L7611 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="G385-1" b2="138 KV" b3="1111 M" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="G385-1" b2="138 KV" b3="BT1120D" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="G385-2" b2="138 KV" b3="1102CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="G385-2" b2="138 KV" b3="BT2-3 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27520</SeqNum>
    <Name>L138.76BlueIsland-7612-43Wildwood.7612</Name>
    <LastEdit Timestamp="2025-12-26T12:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="118 WALL" b2="138 KV" b3="11801 1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="118 WALL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="118 WALL" b2="138 KV" b3="L11801CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="118 WALL" b2="138 KV" b3="L7612 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="43 WILDW" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="43 WILDW" b2="138 KV" b3="TR73_12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="465 S HO" b2="138 KV" b3="1218CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="465 S HO" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="76 BLUE" b2="138 KV" b3="L7612 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="7612" b2="138 KV" b3="761-WALL" />
      <ContingencyEquipment Action="L" Type="LN" b1="76 BLUE" b2="138 KV" b3="7612 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="7612" b2="138 KV" b3="7612 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="7612" b2="138 KV" b3="7612 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="43 WILDW" b2="138 KV" b3="7612 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="7612" b2="138 KV" b3="7612 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="7612" b2="138 KV" b3="7612 7" />
      <ContingencyEquipment Action="S" Type="SD" b1="7612" b2="138 KV" b3="7612 8" />
      <ContingencyEquipment Action="L" Type="LN" b1="7612" b2="138 KV" b3="7612 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="814 DAME" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="814 DAME" b2="138 KV" b3="L11801CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="89 BEVER" b2="138 KV" b3="BT2-3 M" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="89 BEVER" b2="138 KV" b3="L7612 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="G385-2" b2="138 KV" b3="1215CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="G385-2" b2="138 KV" b3="BT2-3 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27530</SeqNum>
    <Name>L138.76BlueIsland-7615-461Crestwood.7615</Name>
    <LastEdit Timestamp="2026-02-10T09:54:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="443 HARV" b2="138 KV" b3="1535" />
      <ContingencyEquipment Action="L" Type="LN" b1="7615" b2="138 KV" b3="7615 3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="443 HARV" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="443 HARV" b2="138 KV" b3="L7615 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="461 CRES" b2="138 KV" b3="11603 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="461 CRES" b2="138 KV" b3="7615 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="461 CRES" b2="138 KV" b3="7615 4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="461 CRES" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="60 ALSIP" b2="138 KV" b3="7615 8" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="60 ALSIP" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="60 ALSIP" b2="138 KV" b3="L7615 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="76 BLUE" b2="138 KV" b3="L7615 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="76 BLUE" b2="138 KV" b3="7615 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="7615" b2="138 KV" b3="7615 6" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="G394" b2="138 KV" b3="BT D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="G394" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27540</SeqNum>
    <Name>L138.BlueIsland-7616-CrestWood-Harvey.7616</Name>
    <LastEdit Timestamp="2025-04-07T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="7616" b2="138 KV" b3="7616 10" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="443 HARV" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="443 HARV" b2="138 KV" b3="L7616 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="461 CRES" b2="138 KV" b3="11609 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="461 CRES" b2="138 KV" b3="7616 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="461 CRES" b2="138 KV" b3="7616 6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="461 CRES" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="60 ALSIP" b2="138 KV" b3="7616 11" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="60 ALSIP" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="60 ALSIP" b2="138 KV" b3="L7616 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="76 BLUE" b2="138 KV" b3="7616 4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="76 BLUE" b2="138 KV" b3="L7616 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="G394" b2="138 KV" b3="7616 8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="G394" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27550</SeqNum>
    <Name>L138.Spaulding-Elgin.7901</Name>
    <LastEdit Timestamp="2024-11-21T14:30:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="79 SPAUL" b2="138 KV" b3="7901" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="570 ELGI" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="570 ELGI" b2="138 KV" b3="L7901 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="138 KV" b3="L7901_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27570</SeqNum>
    <Name>L138.79Spaulding-7902-185Tollway.7902</Name>
    <LastEdit Timestamp="2025-06-20T15:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="185 TOLL" b2="138 KV" b3="7902-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="185 TOLL" b2="138 KV" b3="L7902 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="7902" b2="138 KV" b3="7902 Z2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="563 HANO" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="79 SPAUL" b2="138 KV" b3="7902 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="138 KV" b3="L7902 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27580</SeqNum>
    <Name>L138.79Spaulding-7903-185Tollway.7903</Name>
    <LastEdit Timestamp="2025-06-20T15:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="185 TOLL" b2="138 KV" b3="7903-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="185 TOLL" b2="138 KV" b3="L7903 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="7903" b2="138 KV" b3="7903 Z2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="563 HANO" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="79 SPAUL" b2="138 KV" b3="7903 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="138 KV" b3="L7903 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27590</SeqNum>
    <Name>L138.79Spaulding-7910-144Wayne.7910</Name>
    <LastEdit Timestamp="2026-05-02T16:06:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="144 WAYN" b2="138 KV" b3="7910 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="138 KV" b3="L7910 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="574 BART" b2="138 KV" b3="7910 3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="574 BART" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="574 BART" b2="138 KV" b3="L7910 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="7910" b2="138 KV" b3="7910 2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="577 S EL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="577 S EL" b2="138 KV" b3="L7910 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="79 SPAUL" b2="138 KV" b3="7910 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="138 KV" b3="L7910 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="7910" b2="138 KV" b3="7910 Z2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27600</SeqNum>
    <Name>L138.79Spaulding-7915-144Wayne.7915</Name>
    <LastEdit Timestamp="2024-12-10T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="7915" b2="138 KV" b3="7915 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="138 KV" b3="L7915 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="7915" b2="138 KV" b3="7915 3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="570 ELGI" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="570 ELGI" b2="138 KV" b3="L7915 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="7915" b2="138 KV" b3="7915 5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="574 BART" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="574 BART" b2="138 KV" b3="L7915 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="7915" b2="138 KV" b3="7915 4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="577 S EL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="577 S EL" b2="138 KV" b3="L7915 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="79 SPAUL" b2="138 KV" b3="7915 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="138 KV" b3="L7915 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="7915" b2="138 KV" b3="7915 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="7915" b2="138 KV" b3="7915 Z2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27630</SeqNum>
    <Name>L138.DavisCreek-Kensington-Bradley-K323.8603</Name>
    <LastEdit Timestamp="2025-11-24T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="70 BRADL" b2="138 KV" b3="8603 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="70 BRADL" b2="138 KV" b3="L8603 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="86 DAVIS" b2="138 KV" b3="8603 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="138 KV" b3="L8603 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="8603" b2="138 KV" b3="8603 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="8603" b2="138 KV" b3="8603_4SD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="K323" b2="138 KV" b3="5-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="K323" b2="138 KV" b3="6-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27650</SeqNum>
    <Name>L138.70Bradley-8604-86DavisCreek.8604</Name>
    <LastEdit Timestamp="2025-10-20T10:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="70 BRADL" b2="138 KV" b3="L8604 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="138 KV" b3="L8604 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="86 DAVIS" b2="138 KV" b3="8604 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="8604" b2="138 KV" b3="8604 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="8604" b2="138 KV" b3="8604 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="70 BRADL" b2="138 KV" b3="8604 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="K320" b2="138 KV" b3="8604 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="K319-2" b2="138 KV" b3="8604 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="K319-1" b2="138 KV" b3="8604 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="K319-1" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="K319-1" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="K319-2" b2="138 KV" b3="L8604 CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="K319-2" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="K319-2" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="K320" b2="138 KV" b3="TR71 .4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27670</SeqNum>
    <Name>L138.DavisCreek-8606-K323.8605 G (SPOG 2-16)</Name>
    <LastEdit Timestamp="2025-11-18T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="70 BRADL" b2="138 KV" b3="L8604 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="70 BRADL" b2="138 KV" b3="L8605 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="138 KV" b3="L8605 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="86 DAVIS" b2="138 KV" b3="8605 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="8605" b2="138 KV" b3="8605 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="70 BRADL" b2="138 KV" b3="8605 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="K319-2" b2="138 KV" b3="8605 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="8605" b2="138 KV" b3="8605 6" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="K319-2" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="K319-2" b2="138 KV" b3="L8605 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="K323" b2="138 KV" b3="1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="K323" b2="138 KV" b3="2-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27680</SeqNum>
    <Name>L138.86DavisCreek-Wilmington.8607</Name>
    <LastEdit Timestamp="2025-11-25T16:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="149 WILM" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="149 WILM" b2="138 KV" b3="BT4-5 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="149 WILM" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="86 DAVIS" b2="138 KV" b3="DAV-WILM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="138 KV" b3="L8607 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27690</SeqNum>
    <Name>L138.Skokie-8801-GolfMill-Niles.8801</Name>
    <LastEdit Timestamp="2025-04-08T10:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="8801" b2="138 KV" b3="8801 3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="129 NILE" b2="138 KV" b3="BT3-4 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="129 NILE" b2="138 KV" b3="L8801 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="8801" b2="138 KV" b3="8801 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="L8801 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="88 SKOKI" b2="138 KV" b3="8801 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L8801 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27700</SeqNum>
    <Name>L138.Skokie-8802-GolfMill.8802</Name>
    <LastEdit Timestamp="2025-04-28T15:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="8802" b2="138 KV" b3="8802 3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="129 NILE" b2="138 KV" b3="BT3-4 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="129 NILE" b2="138 KV" b3="L8802 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="8802" b2="138 KV" b3="8802 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="L8802 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="88 SKOKI" b2="138 KV" b3="8802 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L8802 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27710</SeqNum>
    <Name>L138.Skokie-8803-Devon.8803</Name>
    <LastEdit Timestamp="2025-04-10T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="8803" b2="138 KV" b3="8803 4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="110 DEVO" b2="138 KV" b3="8803 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="85 SKOKI" b2="138 KV" b3="8803 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="85 SKOKI" b2="138 KV" b3="8803 Z2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="85 SKOKI" b2="138 KV" b3="B11CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="85 SKOKI" b2="138 KV" b3="BT1213CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="85 SKOKI" b2="138 KV" b3="TR3 34" />
      <ContingencyEquipment Action="L" Type="LN" b1="8803" b2="138 KV" b3="8803 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L8803 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27720</SeqNum>
    <Name>L138.Skokie-8805-Northbrook.8805</Name>
    <LastEdit Timestamp="2025-10-09T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="8805" b2="138 KV" b3="8805 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="159 NORT" b2="138 KV" b3="L8805 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="8805" b2="138 KV" b3="8805 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="258 ELMW" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="258 ELMW" b2="138 KV" b3="L8805 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="88 SKOKI" b2="138 KV" b3="8805 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L8805 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="8805" b2="138 KV" b3="8805 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="8805" b2="138 KV" b3="8805 Z2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="C434" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="C434" b2="138 KV" b3="L8805 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27740</SeqNum>
    <Name>L138.Skokie-8806-Northbrook.8806</Name>
    <LastEdit Timestamp="2025-10-10T13:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="159 NORT" b2="138 KV" b3="L8806 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="258 ELMW" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="258 ELMW" b2="138 KV" b3="L8806 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L8806 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="88 SKOKI" b2="138 KV" b3="8806 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="8806" b2="138 KV" b3="8806 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="8806" b2="138 KV" b3="8806 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="8806" b2="138 KV" b3="8806 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="8806" b2="138 KV" b3="8806 Z2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="C434" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="C434" b2="138 KV" b3="L8806 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27760</SeqNum>
    <Name>L138.85Skokie-8809-110Devon.8809</Name>
    <LastEdit Timestamp="2025-10-28T11:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="8809" b2="138 KV" b3="8809 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="110 DEVO" b2="138 KV" b3="8809 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="47 EVANS" b2="138 KV" b3="8809 4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="47 EVANS" b2="138 KV" b3="BT3-4 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="47 EVANS" b2="138 KV" b3="L8809 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="85 SKOKI" b2="138 KV" b3="8809 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="85 SKOKI" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="8809" b2="138 KV" b3="8809 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L8809 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="8809" b2="138 KV" b3="8809 5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27770</SeqNum>
    <Name>L138.Skokie-8810-Devon.8810</Name>
    <LastEdit Timestamp="2026-02-24T10:53:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="110 DEVO" b2="138 KV" b3="11411 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="8810" b2="138 KV" b3="8810 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="110 DEVO" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="85 SKOKI" b2="138 KV" b3="8810 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="85 SKOKI" b2="138 KV" b3="8810 Z2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="85 SKOKI" b2="138 KV" b3="B14CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="85 SKOKI" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="85 SKOKI" b2="138 KV" b3="BT1213CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="85 SKOKI" b2="138 KV" b3="TR1 34" />
      <ContingencyEquipment Action="L" Type="LN" b1="8810" b2="138 KV" b3="8810 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L8810 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="8810" b2="138 KV" b3="8810 3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27780</SeqNum>
    <Name>L138.103Lisle-10301-120Lombard.10301</Name>
    <LastEdit Timestamp="2024-12-10T16:03:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="138 KV" b3="L10301CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="10301" b2="138 KV" b3="0120 D" />
      <ContingencyEquipment Action="L" Type="LN" b1="103 LISL" b2="138 KV" b3="10301 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="10301" b2="138 KV" b3="10301 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="10301" b2="138 KV" b3="10301 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="120 LOMB" b2="138 KV" b3="10301 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="10301" b2="138 KV" b3="10301 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="10301" b2="138 KV" b3="10301 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="10301" b2="138 KV" b3="10301 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="10301" b2="138 KV" b3="10301 Z3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="138 KV" b3="L10301CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="120 LOMB" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="120 LOMB" b2="138 KV" b3="TR79 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="34.5 KV" b3="TR79 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="145 YORK" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="145 YORK" b2="138 KV" b3="L10301CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="555 GLEN" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="557 BUTT" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27790</SeqNum>
    <Name>L138.Lisle-10302-Lombard</Name>
    <LastEdit Timestamp="2026-03-31T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="138 KV" b3="L10302CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="103 LISL" b2="138 KV" b3="10302 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="10302" b2="138 KV" b3="10302 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="10302" b2="138 KV" b3="10302 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="10302" b2="138 KV" b3="10302 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="10302" b2="138 KV" b3="10302 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="120 LOMB" b2="138 KV" b3="10302 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="10302" b2="138 KV" b3="10302 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="10302" b2="138 KV" b3="10302 Z3" />
      <ContingencyEquipment Action="S" Type="SD" b1="10302" b2="138 KV" b3="10302 Z4" />
      <ContingencyEquipment Action="L" Type="LN" b1="10302" b2="138 KV" b3="10302 Z5" />
      <ContingencyEquipment Action="L" Type="LN" b1="10302" b2="138 KV" b3="13506 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="138 KV" b3="L10302CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="120 LOMB" b2="138 KV" b3="TR76 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="34.5 KV" b3="TR76 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="145 YORK" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="145 YORK" b2="138 KV" b3="L10302CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="555 GLEN" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="557 BUTT" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27800</SeqNum>
    <Name>L138.Dixon-McGirrRd.10714</Name>
    <LastEdit Timestamp="2026-04-21T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="107 DIXO" b2="138 KV" b3="10714" />
      <ContingencyEquipment Action="OP" Type="CB" b1="107 DIXO" b2="138 KV" b3="L10714CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="169 MCGI" b2="138 KV" b3="L10714CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27810</SeqNum>
    <Name>L138.McGirrRoad-RichieRd-Steward.16914</Name>
    <LastEdit Timestamp="2026-03-02T17:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="169 MCGI" b2="138 KV" b3="L16914CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="16914" b2="138 KV" b3="16914 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="16914" b2="138 KV" b3="16914 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="16914" b2="138 KV" b3="16914_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="186 STEW" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H447RR" b2="138 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H447RR" b2="138 KV" b3="2-9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27820</SeqNum>
    <Name>L138.McGirrRd-Mendota-ShadyOaks.16901</Name>
    <LastEdit Timestamp="2026-03-02T17:40:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="100 SHAD" b2="138 KV" b3="16901 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="100 SHAD" b2="138 KV" b3="L16901CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="169 MCGI" b2="138 KV" b3="L16901CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="16901" b2="138 KV" b3="16901 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="16901" b2="138 KV" b3="16901 Z1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="979 MEND" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="979 MEND" b2="34.5 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="979 MEND" b2="138 KV" b3="L16901CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="979 MEND" b2="34.5 KV" b3="MENDOTWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="979 MEND" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27830</SeqNum>
    <Name>L138.167Plano-14304-143WolfsCrossing.14304</Name>
    <LastEdit Timestamp="2025-05-16T15:44:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="106 MONT" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="106 MONT" b2="138 KV" b3="L14304CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="143 WOLF" b2="138 KV" b3="L14304CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="14304" b2="138 KV" b3="14304 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="14304" b2="138 KV" b3="14304 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="14304" b2="138 KV" b3="14304 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="14304" b2="138 KV" b3="14304 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="167 PLAN" b2="138 KV" b3="14304 5" />
      <ContingencyEquipment Action="S" Type="SD" b1="14304" b2="138 KV" b3="14304 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="14304" b2="138 KV" b3="14304 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="14304" b2="138 KV" b3="14304 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="14304" b2="138 KV" b3="14304 Z5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="138 KV" b3="L14304CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="521 BRIS" b2="138 KV" b3="1-2 DIS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="521 BRIS" b2="138 KV" b3="SW2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="592 OSWE" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="592 OSWE" b2="138 KV" b3="L14304CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="W507" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="W507" b2="138 KV" b3="L14304 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27840</SeqNum>
    <Name>L138.Electric Jct-11102-Wolfs-Warrenville-Frontnac</Name>
    <LastEdit Timestamp="2026-04-03T10:39:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="L11102CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="11102" b2="138 KV" b3="11102 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="11102" b2="138 KV" b3="11102 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="11102" b2="138 KV" b3="11102 8" />
      <ContingencyEquipment Action="L" Type="LN" b1="11102" b2="138 KV" b3="11102 9" />
      <ContingencyEquipment Action="L" Type="LN" b1="11102" b2="138 KV" b3="11102 Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="143 WOLF" b2="138 KV" b3="11102 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="539 WVIL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="539 WVIL" b2="138 KV" b3="L11102CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="581 FRON" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="581 FRON" b2="138 KV" b3="L11102CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27850</SeqNum>
    <Name>L138.ElectricJct-Aurora.11103</Name>
    <LastEdit Timestamp="2026-04-01T13:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="111 ELEC" b2="138 KV" b3="11103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="L11103CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="138 KV" b3="L11103CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27860</SeqNum>
    <Name>L138.ElectricJct-11104-NorthAurora-SugarGr.11104</Name>
    <LastEdit Timestamp="2026-02-10T09:58:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="11104" b2="138 KV" b3="11104 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="L11104CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="569 SUGA" b2="138 KV" b3="11104 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="11104" b2="138 KV" b3="11104 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="56 NO AU" b2="138 KV" b3="11104 Z4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="56 NO AU" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="56 NO AU" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="56 NO AU" b2="138 KV" b3="TR78 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="56 NO AU" b2="34.5 KV" b3="TR78 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="56 NO AU" b2="138 KV" b3="TR79 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="56 NO AU" b2="34.5 KV" b3="TR79 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="569 SUGA" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="569 SUGA" b2="138 KV" b3="L11104CS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="W541 GFX" b2="138 KV" b3="1-2CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="11104" b2="138 KV" b3="11104 Z3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="W541 GFX" b2="138 KV" b3="L11104CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27870</SeqNum>
    <Name>L138.ElectricJct-Aurora.11105</Name>
    <LastEdit Timestamp="2026-04-01T13:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="111 ELEC" b2="138 KV" b3="11105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="L11105CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="138 KV" b3="L11105CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27880</SeqNum>
    <Name>L138.11106ElctricJct-NoAur-CregoRd-Waterman</Name>
    <LastEdit Timestamp="2025-08-11T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="11106" b2="138 KV" b3="11106 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="L11106CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="11106" b2="138 KV" b3="11106 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="11106" b2="138 KV" b3="11106 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="113 WATE" b2="138 KV" b3="11106 6" />
      <ContingencyEquipment Action="S" Type="SD" b1="11106" b2="138 KV" b3="11106 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="11106" b2="138 KV" b3="11106 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="569 SUGA" b2="138 KV" b3="11106 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="189_CREG" b2="138 KV" b3="CRE-1110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="113 WATE" b2="138 KV" b3="L11106CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="189_CREG" b2="138 KV" b3="10-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="189_CREG" b2="138 KV" b3="11-12" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="56 NO AU" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="56 NO AU" b2="138 KV" b3="L11106CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="56 NO AU" b2="138 KV" b3="TR76 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="56 NO AU" b2="34.5 KV" b3="TR76 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="56 NO AU" b2="138 KV" b3="TR77 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="56 NO AU" b2="34.5 KV" b3="TR77 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="569 SUGA" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="569 SUGA" b2="138 KV" b3="L11106CS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="W541 GFX" b2="138 KV" b3="1-2CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="11106" b2="138 KV" b3="11106 Z3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="W541 GFX" b2="138 KV" b3="L11106CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27890</SeqNum>
    <Name>L138.111ElectricJct-11110-143WolfsCrossing.11110</Name>
    <LastEdit Timestamp="2025-06-19T10:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="L11110CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="111 ELEC" b2="138 KV" b3="11110 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="11110" b2="138 KV" b3="11110 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="W600" b2="138 KV" b3="11110 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="143 WOLF" b2="138 KV" b3="11110 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="11110" b2="138 KV" b3="11110 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="143 WOLF" b2="138 KV" b3="L11110CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="581 FRON" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="581 FRON" b2="138 KV" b3="L11110CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W600" b2="138 KV" b3="L11110CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27900</SeqNum>
    <Name>L138.113WaterMan-146Sandwich.11301 </Name>
    <LastEdit Timestamp="2025-10-10T13:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="113 WATE" b2="138 KV" b3="11301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="113 WATE" b2="138 KV" b3="L11301CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="146 SAND" b2="138 KV" b3="11301 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="146 SAND" b2="138 KV" b3="609-301" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="146 SAND" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="146 SAND" b2="138 KV" b3="BT3-4 D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27920</SeqNum>
    <Name>L138.NorthWest-Rosehill.11407</Name>
    <LastEdit Timestamp="2025-02-25T19:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="114 NORT" b2="138 KV" b3="11407" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT710 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT712 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="84 ROSEH" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27930</SeqNum>
    <Name>L138.NorthWest-RoseHill.11408</Name>
    <LastEdit Timestamp="2025-04-07T15:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="114 NORT" b2="138 KV" b3="11408" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT722 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT724 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="84 ROSEH" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27940</SeqNum>
    <Name>L138.114Northwest-110Devon.11411</Name>
    <LastEdit Timestamp="2024-06-12T13:40:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="114 NORT" b2="138 KV" b3="11411 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="110 DEVO" b2="138 KV" b3="11411 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT721 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT723 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27950</SeqNum>
    <Name>L138.114Northwest-37Natoma.11412</Name>
    <LastEdit Timestamp="2024-06-12T12:33:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="37 NATOM" b2="138 KV" b3="11412" />
      <ContingencyEquipment Action="S" Type="SD" b1="114 NORT" b2="138 KV" b3="11412 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT122 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT724 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT727 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="114 NORT" b2="138 KV" b3="I11412" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT2121CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT721 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT722 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27960</SeqNum>
    <Name>L138.Diversity-Northwest.11413 G (SPOG 2-22)</Name>
    <LastEdit Timestamp="2025-03-31T00:12:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="114 NORT" b2="138 KV" b3="11413" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT730 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT733 CB" />
      <ContingencyEquipment Action="P" Type="XF" b1="114 NORT" b2="138 KV" b3="P11413" />
      <ContingencyEquipment Action="X" Type="XF" b1="114 NORT" b2="138 KV" b3="P1141338" />
      <ContingencyEquipment Action="X" Type="XF" b1="114 NORT" b2="138 KV" b3="Z1141338" />
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT1-5 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT2-11CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27980</SeqNum>
    <Name>L138.114Northwest-84Rose-110Devon.11414</Name>
    <LastEdit Timestamp="2024-06-12T13:58:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="110 DEVO" b2="138 KV" b3="11414 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="110 DEVO" b2="138 KV" b3="11414 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="114 NORT" b2="138 KV" b3="11414 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT728 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT730 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="84 ROSEH" b2="138 KV" b3="11414 3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="84 ROSEH" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>27990</SeqNum>
    <Name>L138.114Northwest-110Devon-84Rose.11415</Name>
    <LastEdit Timestamp="2024-06-12T13:58:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="110 DEVO" b2="138 KV" b3="11415 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="110 DEVO" b2="138 KV" b3="11415 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="114 NORT" b2="138 KV" b3="11415 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT122 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT716 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT717 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="84 ROSEH" b2="138 KV" b3="11415 3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="84 ROSEH" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28000</SeqNum>
    <Name>L138.Northwest-Devon-11416-Skokie.11416</Name>
    <LastEdit Timestamp="2026-04-03T10:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="114 NORT" b2="138 KV" b3="11416 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="11416" b2="138 KV" b3="11416 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="110 DEVO" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT712 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT714 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="11416" b2="138 KV" b3="11416 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="85 SKOKI" b2="138 KV" b3="11416 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="47 EVANS" b2="138 KV" b3="11416 5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="47 EVANS" b2="138 KV" b3="BT3-4 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="47 EVANS" b2="138 KV" b3="L11416CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="85 SKOKI" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="85 SKOKI" b2="138 KV" b3="TR4 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L11416CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28010</SeqNum>
    <Name>L138.114Northwest-37Natoma.11417</Name>
    <LastEdit Timestamp="2025-08-22T10:09:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="37 NATOM" b2="138 KV" b3="11417" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT707 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT709 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="114 NORT" b2="138 KV" b3="I11417" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT89 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT91 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28030</SeqNum>
    <Name>L138.114NorthWest-40Diversey.11418</Name>
    <LastEdit Timestamp="2025-10-09T10:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="114 NORT" b2="138 KV" b3="11418" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT709 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT711 CB" />
      <ContingencyEquipment Action="P" Type="XF" b1="114 NORT" b2="138 KV" b3="P11418" />
      <ContingencyEquipment Action="X" Type="XF" b1="114 NORT" b2="138 KV" b3="P1141838" />
      <ContingencyEquipment Action="X" Type="XF" b1="114 NORT" b2="138 KV" b3="Z1141838" />
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT8-9 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28040</SeqNum>
    <Name>L138.115BedfordPark-37HayFord-469EverGreenPk.11521</Name>
    <LastEdit Timestamp="2024-05-15T10:42:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="115 BEDF" b2="138 KV" b3="11521 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="138 KV" b3="L11521CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="469 EVRG" b2="138 KV" b3="11521 2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="33 HAYFO" b2="138 KV" b3="71L11521" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="33 HAYFO" b2="138 KV" b3="71L1322M" />
      <ContingencyEquipment Action="CL" Type="CB" b1="469 EVRG" b2="138 KV" b3="BT1-2_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="469 EVRG" b2="138 KV" b3="L81414CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="814 DAME" b2="138 KV" b3="BT2-3 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28050</SeqNum>
    <Name>L138.BedfordPark-Hayford-EvergreenPark.11523</Name>
    <LastEdit Timestamp="2026-05-04T15:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="115 BEDF" b2="138 KV" b3="11523 1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="115 BEDF" b2="138 KV" b3="11523TBD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="138 KV" b3="L11523CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="115 BEDF" b2="138 KV" b3="TR77 34" />
      <ContingencyEquipment Action="L" Type="LN" b1="469 EVRG" b2="138 KV" b3="11523 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="33 HAYFO" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="CL" Type="CB" b1="469 EVRG" b2="138 KV" b3="BT1-2_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="469 EVRG" b2="138 KV" b3="L11523CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28060</SeqNum>
    <Name>L138.116GoodingsGrove-11603-461CrestWood.11603</Name>
    <LastEdit Timestamp="2025-06-19T10:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="116 GOOD" b2="138 KV" b3="11603 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="138 KV" b3="L11603CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="461 CRES" b2="138 KV" b3="11603 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="11603" b2="138 KV" b3="11603 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="11603" b2="138 KV" b3="11603 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="11603" b2="138 KV" b3="11603 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="419 TINL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="419 TINL" b2="138 KV" b3="L11603CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="461 CRES" b2="138 KV" b3="11603 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="461 CRES" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="470 ORLA" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="470 ORLA" b2="138 KV" b3="L11603CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28070</SeqNum>
    <Name>L138.116GoodingsGrove-11605-115BedfordPark.11605</Name>
    <LastEdit Timestamp="2025-06-19T10:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="115 BEDF" b2="138 KV" b3="11605 4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="115 BEDF" b2="138 KV" b3="11605TBD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="138 KV" b3="L11605CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="115 BEDF" b2="138 KV" b3="TR76 34" />
      <ContingencyEquipment Action="L" Type="LN" b1="116 GOOD" b2="138 KV" b3="11605 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="138 KV" b3="L11605CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="11605" b2="138 KV" b3="11605 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="11605" b2="138 KV" b3="11605 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="11605" b2="138 KV" b3="11605 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="11605" b2="138 KV" b3="11605 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="11605" b2="138 KV" b3="11605 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="11605" b2="138 KV" b3="11605 Z3" />
      <ContingencyEquipment Action="L" Type="LN" b1="11605" b2="138 KV" b3="11605 Z4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="414 ROBE" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="440 PALO" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="517 SAYR" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="517 SAYR" b2="138 KV" b3="L11605CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="531 BRID" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28080</SeqNum>
    <Name>L138.GoodingsGrove-11606-BedfordPk.11606</Name>
    <LastEdit Timestamp="2025-04-07T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="115 BEDF" b2="138 KV" b3="11606 4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="115 BEDF" b2="138 KV" b3="11606TBD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="138 KV" b3="L11606CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="116 GOOD" b2="138 KV" b3="11606 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="138 KV" b3="L11606CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="11606" b2="138 KV" b3="11606 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="11606" b2="138 KV" b3="11606 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="11606" b2="138 KV" b3="11606 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="11606" b2="138 KV" b3="11606 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="11606" b2="138 KV" b3="11606 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="11606" b2="138 KV" b3="11606 Z3" />
      <ContingencyEquipment Action="L" Type="LN" b1="11606" b2="138 KV" b3="11606 Z4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="414 ROBE" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="440 PALO" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="517 SAYR" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="517 SAYR" b2="138 KV" b3="L11606CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="531 BRID" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28090</SeqNum>
    <Name>L138.GoodingsGrove-11609-CrestWood-TinleyPk.11609</Name>
    <LastEdit Timestamp="2025-04-07T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="116 GOOD" b2="138 KV" b3="11609 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="138 KV" b3="L11609CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="461 CRES" b2="138 KV" b3="11609 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="11609" b2="138 KV" b3="11609 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="11609" b2="138 KV" b3="11609 9" />
      <ContingencyEquipment Action="L" Type="LN" b1="11609" b2="138 KV" b3="11609 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="419 TINL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="419 TINL" b2="138 KV" b3="L11609CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="461 CRES" b2="138 KV" b3="11609 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="461 CRES" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="470 ORLA" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="470 ORLA" b2="138 KV" b3="L11609CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28110</SeqNum>
    <Name>L138.ProspectHeights-Desplains.11701</Name>
    <LastEdit Timestamp="2026-04-03T10:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="117 PROS" b2="138 KV" b3="11701 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="L11701CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="46 DESPL" b2="138 KV" b3="11701 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="11701" b2="138 KV" b3="11701 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="216 MOUN" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L11701CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28130</SeqNum>
    <Name>L138.ProspectHeights-Desplains.11702</Name>
    <LastEdit Timestamp="2026-04-03T10:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="117 PROS" b2="138 KV" b3="11702 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="L11702CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="46 DESPL" b2="138 KV" b3="11702 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="11702" b2="138 KV" b3="11702 3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="216 MOUN" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L11702CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28150</SeqNum>
    <Name>L138.ProspectHeights-Palatine.11703</Name>
    <LastEdit Timestamp="2025-12-26T12:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="102 PALA" b2="138 KV" b3="11703 2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="102 PALA" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="102 PALA" b2="138 KV" b3="L11703CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="117 PROS" b2="138 KV" b3="11703 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="L11703CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="11703" b2="138 KV" b3="11703 3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="268 ARLI" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="268 ARLI" b2="138 KV" b3="L11703CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28160</SeqNum>
    <Name>L138.ProspectHeights-Aptakisik.11704</Name>
    <LastEdit Timestamp="2026-04-03T10:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="109 APTA" b2="138 KV" b3="11704 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="109 APTA" b2="138 KV" b3="L11704CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="11704" b2="138 KV" b3="11704 6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="L11704CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="11704" b2="138 KV" b3="11704 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="11704" b2="138 KV" b3="11704 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="11704" b2="138 KV" b3="11704 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="11704" b2="138 KV" b3="11704 Z3" />
      <ContingencyEquipment Action="L" Type="LN" b1="11704" b2="138 KV" b3="11704 Z4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="205 WHEE" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="217 PROS" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="237 BUFF" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28170</SeqNum>
    <Name>L138.ProspectHeights-Palatine.11705</Name>
    <LastEdit Timestamp="2025-12-26T13:10:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="102 PALA" b2="138 KV" b3="11705 2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="102 PALA" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="102 PALA" b2="138 KV" b3="L11705CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="117 PROS" b2="138 KV" b3="11705 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="L11705CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="11705" b2="138 KV" b3="11705 3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="268 ARLI" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="268 ARLI" b2="138 KV" b3="L11705CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28210</SeqNum>
    <Name>L138.Lancaster-11902-Maryland.11902</Name>
    <LastEdit Timestamp="2025-04-07T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="119 LANC" b2="138 KV" b3="11902 8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="119 LANC" b2="138 KV" b3="L11902CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="180 LENA" b2="138 KV" b3="11902 10" />
      <ContingencyEquipment Action="L" Type="LN" b1="124 MARY" b2="138 KV" b3="11902 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="11902" b2="138 KV" b3="11902 5" />
      <ContingencyEquipment Action="S" Type="SD" b1="11902" b2="138 KV" b3="11902 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="11902" b2="138 KV" b3="11902 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="11902" b2="138 KV" b3="11902 9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="124 MARY" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="124 MARY" b2="138 KV" b3="TR76 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="124 MARY" b2="34.5 KV" b3="TR76 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="180 LENA" b2="138 KV" b3="BT2-3CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="180 LENA" b2="138 KV" b3="L11902CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="370 ELER" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="370 ELER" b2="138 KV" b3="L11902CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="B427" b2="138 KV" b3="L11902CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28220</SeqNum>
    <Name>L138.Lombard-GraceAv-Addison-Church-Elmhurst.12007</Name>
    <LastEdit Timestamp="2024-11-18T13:14:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="120 LOMB" b2="138 KV" b3="12007 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="138 KV" b3="L12007CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="135 ELMH" b2="138 KV" b3="12007 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="138 KV" b3="L12007CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="552 ADDI" b2="138 KV" b3="12007 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="552 ADDI" b2="138 KV" b3="12007 4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="552 ADDI" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="560 GRAC" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="568 CHUR" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="568 CHUR" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28230</SeqNum>
    <Name>L138.Lombard-12008-Addison-Elmhurst.12008 </Name>
    <LastEdit Timestamp="2025-06-23T15:40:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="120 LOMB" b2="138 KV" b3="12008 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="138 KV" b3="L12008CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="12008" b2="138 KV" b3="12008 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="595 PLSN" b2="138 KV" b3="12008 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="135 ELMH" b2="138 KV" b3="12008 5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="138 KV" b3="L12008CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="552 ADDI" b2="138 KV" b3="12008 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="552 ADDI" b2="138 KV" b3="12008 4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="552 ADDI" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="560 GRAC" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="568 CHUR" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="568 CHUR" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="595 PLSN" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="595 PLSN" b2="138 KV" b3="L12008CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28240</SeqNum>
    <Name>L138.120Lombard-595PleasantHill.12011</Name>
    <LastEdit Timestamp="2025-06-19T12:07:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="595 PLSN" b2="138 KV" b3="12011 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="138 KV" b3="L12011CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="120 LOMB" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="595 PLSN" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="595 PLSN" b2="138 KV" b3="L12011CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28250</SeqNum>
    <Name>L138.120Lombard-12015-101Itasca.12015</Name>
    <LastEdit Timestamp="2024-12-10T14:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="101 ITAS" b2="138 KV" b3="12015 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="8-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="9-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="138 KV" b3="L12015CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="120 LOMB" b2="138 KV" b3="TR77 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="34.5 KV" b3="TR77 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="120 LOMB" b2="138 KV" b3="12015 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="12015" b2="138 KV" b3="12015 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="12015" b2="138 KV" b3="12015 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="12015" b2="138 KV" b3="12015 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="562 GLEN" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="562 GLEN" b2="138 KV" b3="L12015CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="565 NORD" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28260</SeqNum>
    <Name>L138.120Lombard-12016-101Itasca.12016</Name>
    <LastEdit Timestamp="2025-10-08T14:31:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="101 ITAS" b2="138 KV" b3="12016 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="14-15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="15-16" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="101 ITAS" b2="138 KV" b3="DUM00043" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="101 ITAS" b2="138 KV" b3="DUME1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="138 KV" b3="L12016CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="120 LOMB" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="120 LOMB" b2="138 KV" b3="12016 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="12016" b2="138 KV" b3="12016 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="12016" b2="138 KV" b3="12016 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="12016" b2="138 KV" b3="12016 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="562 GLEN" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="562 GLEN" b2="138 KV" b3="L12016CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="565 NORD" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28270</SeqNum>
    <Name>L138.122Belvidere-123Marengo-141Pleasant.12204</Name>
    <LastEdit Timestamp="2024-06-12T13:55:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="12204" b2="138 KV" b3="12204 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="122 BELV" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="12204" b2="138 KV" b3="12204 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="12204" b2="138 KV" b3="12204 5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="123 MARE" b2="138 KV" b3="05 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="123 MARE" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="123 MARE" b2="138 KV" b3="L12204CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="141 PLEA" b2="138 KV" b3="L12204CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28280</SeqNum>
    <Name>L135.122Belvidere-12205-123Marengo.12205</Name>
    <LastEdit Timestamp="2024-12-12T14:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="122 BELV" b2="138 KV" b3="0507CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="122 BELV" b2="138 KV" b3="12205 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="122 BELV" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="122 BELV" b2="138 KV" b3="TR79 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="122 BELV" b2="34.5 KV" b3="TR79 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="151 WOOD" b2="138 KV" b3="12205 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="123 MARE" b2="138 KV" b3="12205 5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="123 MARE" b2="138 KV" b3="05 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="123 MARE" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="123 MARE" b2="138 KV" b3="L12205CS" />
      <ContingencyEquipment Action="S" Type="SD" b1="151 WOOD" b2="138 KV" b3="12205 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="151 WOOD" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="151 WOOD" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="151 WOOD" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28290</SeqNum>
    <Name>L138.Maryland-12411-Dixon.12411</Name>
    <LastEdit Timestamp="2025-06-20T15:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="107 DIXO" b2="138 KV" b3="12411 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="107 DIXO" b2="138 KV" b3="L12411CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="124 MARY" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="124 MARY" b2="138 KV" b3="TR77 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="124 MARY" b2="34.5 KV" b3="TR77 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="124 MARY" b2="138 KV" b3="12411 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="372 STER" b2="138 KV" b3="12411 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="372 STER" b2="138 KV" b3="12411 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="372 STER" b2="138 KV" b3="12411CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="372 STER" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="372 STER" b2="138 KV" b3="L12411CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28300</SeqNum>
    <Name>L138.132GardenPlain-Albany.13219</Name>
    <LastEdit Timestamp="2024-06-12T14:04:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="132 GARD" b2="138 KV" b3="13219" />
      <ContingencyEquipment Action="OP" Type="CB" b1="132 GARD" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="132 GARD" b2="138 KV" b3="TR77 34" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ALBANY" b2="138 KV" b3="DUM02658" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28310</SeqNum>
    <Name>L138.Elmhurst-13501-Bellwood-Berkeley.13501</Name>
    <LastEdit Timestamp="2025-05-15T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="138 KV" b3="L13501CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="135 ELMH" b2="138 KV" b3="13501 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="64 BELLW" b2="138 KV" b3="13501 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="13501" b2="138 KV" b3="13501 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="13501" b2="138 KV" b3="13501 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="13501" b2="138 KV" b3="13501 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="13501" b2="138 KV" b3="13501 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="13501" b2="138 KV" b3="13501 Z3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="549 BERK" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="549 BERK" b2="138 KV" b3="L13501CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="138 KV" b3="L13501CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="D787" b2="138 KV" b3="13501 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="D787" b2="138 KV" b3="BT1-2 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28320</SeqNum>
    <Name>L138.Elmhurst-13502-Bellwood-Berkeley.13502</Name>
    <LastEdit Timestamp="2025-11-25T16:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="138 KV" b3="L13502CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="135 ELMH" b2="138 KV" b3="13502 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="64 BELLW" b2="138 KV" b3="13502 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="13502" b2="138 KV" b3="13502 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="13502" b2="138 KV" b3="13502 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="13502" b2="138 KV" b3="13502 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="13502" b2="138 KV" b3="13502 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="13502" b2="138 KV" b3="13502 Z3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="549 BERK" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="549 BERK" b2="138 KV" b3="L13502CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="138 KV" b3="14-15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="138 KV" b3="BT1115CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="64 BELLW" b2="138 KV" b3="TR76 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="34.5 KV" b3="TR76 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="D787" b2="138 KV" b3="13502 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="D787" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="D789" b2="138 KV" b3="TR71" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28330</SeqNum>
    <Name>L138.135Elmhurst-78Franklin.13503</Name>
    <LastEdit Timestamp="2026-01-08T08:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="135 ELMH" b2="138 KV" b3="13503" />
      <ContingencyEquipment Action="L" Type="LN" b1="78 FRANK" b2="138 KV" b3="13503 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="138 KV" b3="L13503CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="138 KV" b3="BT2-6 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="78 FRANK" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="78 FRANK" b2="34.5 KV" b3="TR77" />
      <ContingencyEquipment Action="X" Type="XF" b1="78 FRANK" b2="138 KV" b3="TR77 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="34.5 KV" b3="TR77 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28340</SeqNum>
    <Name>L138.135Elmhurst-78FranklinPark.13504</Name>
    <LastEdit Timestamp="2026-01-06T11:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="78 FRANK" b2="138 KV" b3="13504" />
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="138 KV" b3="L13504CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="138 KV" b3="BT4-6 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="78 FRANK" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="78 FRANK" b2="138 KV" b3="TR79 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="34.5 KV" b3="TR79 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28350</SeqNum>
    <Name>L138.135Elmhurst-13505-566OakBrook.13505</Name>
    <LastEdit Timestamp="2025-06-19T12:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="138 KV" b3="L13505CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="135 ELMH" b2="138 KV" b3="13505 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="10301" b2="138 KV" b3="13505 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="566 OAKB" b2="138 KV" b3="13505 Z4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="566 OAKB" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="566 OAKB" b2="138 KV" b3="L13505CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28360</SeqNum>
    <Name>L138.135Elmhurst-13506-566OakBrook.13506</Name>
    <LastEdit Timestamp="2025-06-19T12:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="138 KV" b3="L13506CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="135 ELMH" b2="138 KV" b3="13506 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="10302" b2="138 KV" b3="13506 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="566 OAKB" b2="138 KV" b3="13506 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="566 OAKB" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="566 OAKB" b2="138 KV" b3="L13506CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28370</SeqNum>
    <Name>L138.135Elmhurst-78Franklin.13510</Name>
    <LastEdit Timestamp="2025-05-13T08:03:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="135 ELMH" b2="138 KV" b3="13510" />
      <ContingencyEquipment Action="L" Type="LN" b1="78 FRANK" b2="138 KV" b3="13510 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="138 KV" b3="L13510CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="138 KV" b3="BT3-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="138 KV" b3="BT5-8CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28380</SeqNum>
    <Name>L138.137WashingtonPk-45Jefferson-197GrenShaw.13701</Name>
    <LastEdit Timestamp="2025-06-19T12:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="45 JEFFE" b2="138 KV" b3="13701 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="137 WASH" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="137 WASH" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="137 WASH" b2="138 KV" b3="TR74-X12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="137 WASH" b2="138 KV" b3="TR74-Y12" />
      <ContingencyEquipment Action="L" Type="LN" b1="45 JEFFE" b2="138 KV" b3="13701 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="197 GREN" b2="138 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="197 GREN" b2="138 KV" b3="BT7-8 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28390</SeqNum>
    <Name>L138.Taylor-Grenshaw.15310</Name>
    <LastEdit Timestamp="2026-04-03T10:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT2223CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT2324CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="153 TAYL" b2="138 KV" b3="15310" />
      <ContingencyEquipment Action="OP" Type="CB" b1="197 GREN" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="197 GREN" b2="138 KV" b3="BT6-7 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28400</SeqNum>
    <Name>L138.7State-WolfLake</Name>
    <LastEdit Timestamp="2024-06-12T14:10:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="17WOLFLK" b2="138 KV" b3="BUST" />
      <ContingencyEquipment Action="X" Type="XF" b1="17WOLFLK" b2="138 KV" b3="X1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17WOLFLK" b2="34 KV" b3="X1DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="138 KV" b3="L13803CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="7 STATE" b2="138 KV" b3="STA-17W1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28410</SeqNum>
    <Name>L138.138SilverLake-13805-260Dundee.13805</Name>
    <LastEdit Timestamp="2024-12-12T14:00:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="102 PALA" b2="138 KV" b3="0334D" />
      <ContingencyEquipment Action="L" Type="LN" b1="233 BARR" b2="138 KV" b3="BAR-PALA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="138 KV" b3="L13805CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="138 SILV" b2="138 KV" b3="13805 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="13805" b2="138 KV" b3="13805 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="260 DUND" b2="138 KV" b3="13805 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="13805" b2="138 KV" b3="13805 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="13805" b2="138 KV" b3="13805 5" />
      <ContingencyEquipment Action="S" Type="SD" b1="13805" b2="138 KV" b3="13805 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="250 BARR" b2="138 KV" b3="13805 Z2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="233 BARR" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="233 BARR" b2="138 KV" b3="L13805CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="240 CARY" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="240 CARY" b2="138 KV" b3="L13805CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="250 BARR" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="260 DUND" b2="138 KV" b3="13805CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28420</SeqNum>
    <Name>L138.138SilverLake-13806-260Dundee.13806</Name>
    <LastEdit Timestamp="2024-12-12T13:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="138 KV" b3="L13806CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="138 SILV" b2="138 KV" b3="13806 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="13806" b2="138 KV" b3="13806 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="260 DUND" b2="138 KV" b3="13806 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="13806" b2="138 KV" b3="13806 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="13806" b2="138 KV" b3="13806 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="233 BARR" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="233 BARR" b2="138 KV" b3="L13806CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="240 CARY" b2="138 KV" b3="BT1-2 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="240 CARY" b2="138 KV" b3="L13806CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="260 DUND" b2="138 KV" b3="13806CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="260 DUND" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28450</SeqNum>
    <Name>L138.7State-Roxana</Name>
    <LastEdit Timestamp="2024-06-12T14:14:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="17ROXANA" b2="138 KV" b3="53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="138 KV" b3="L13853CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="7 STATE" b2="138 KV" b3="STA-17R1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28460</SeqNum>
    <Name>L138.PleasantValley-CrystalLake.14101 S</Name>
    <LastEdit Timestamp="2026-04-03T11:06:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="75 CRYST" b2="138 KV" b3="14101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="141 PLEA" b2="138 KV" b3="L14101CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="75 CRYST" b2="138 KV" b3="0418 S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="75 CRYST" b2="138 KV" b3="13808CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="75 CRYST" b2="138 KV" b3="BT2-3 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28470</SeqNum>
    <Name>L138.PleasantValley-14102-Tollway.14102</Name>
    <LastEdit Timestamp="2025-12-04T17:35:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="141 PLEA" b2="138 KV" b3="L14102CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="141 PLEA" b2="138 KV" b3="14102 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="259 ALGO" b2="138 KV" b3="14102 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="510 WEST" b2="138 KV" b3="14102 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="572 GILB" b2="138 KV" b3="14102 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="185 TOLL" b2="138 KV" b3="14102 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="221 N HU" b2="138 KV" b3="14102 Z1" />
      <ContingencyEquipment Action="S" Type="SD" b1="14102" b2="138 KV" b3="14102 Z2" />
      <ContingencyEquipment Action="S" Type="SD" b1="14102" b2="138 KV" b3="14102 Z3" />
      <ContingencyEquipment Action="S" Type="SD" b1="14102" b2="138 KV" b3="14102 Z4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="185 TOLL" b2="138 KV" b3="L14102CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="221 N HU" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="221 N HU" b2="138 KV" b3="L14102CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="259 ALGO" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="259 ALGO" b2="138 KV" b3="L14102CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="510 WEST" b2="138 KV" b3="14102CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="510 WEST" b2="138 KV" b3="BT1-2 LS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="572 GILB" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="572 GILB" b2="138 KV" b3="L14102CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28480</SeqNum>
    <Name>L138.PleasantValley-14103-Tollway.14103</Name>
    <LastEdit Timestamp="2025-12-04T17:35:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="141 PLEA" b2="138 KV" b3="L14103CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="141 PLEA" b2="138 KV" b3="14103 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="259 ALGO" b2="138 KV" b3="14103 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="510 WEST" b2="138 KV" b3="14103 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="572 GILB" b2="138 KV" b3="14103 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="221 N HU" b2="138 KV" b3="14103 Z1" />
      <ContingencyEquipment Action="S" Type="SD" b1="14103" b2="138 KV" b3="14103 Z2" />
      <ContingencyEquipment Action="S" Type="SD" b1="14103" b2="138 KV" b3="14103 Z3" />
      <ContingencyEquipment Action="S" Type="SD" b1="14103" b2="138 KV" b3="14103 Z4" />
      <ContingencyEquipment Action="L" Type="LN" b1="185 TOLL" b2="138 KV" b3="14103 5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="185 TOLL" b2="138 KV" b3="L14103CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="221 N HU" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="221 N HU" b2="138 KV" b3="L14103CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="259 ALGO" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="259 ALGO" b2="138 KV" b3="L14103CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="510 WEST" b2="138 KV" b3="BT1-2 LS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="510 WEST" b2="138 KV" b3="DUM4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="572 GILB" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="572 GILB" b2="138 KV" b3="L14103CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28500</SeqNum>
    <Name>L138.Wayne-WestChicago.14403 (SPOG 3-30)</Name>
    <LastEdit Timestamp="2025-10-14T18:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="14403" b2="138 KV" b3="14403 4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="131 W CH" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="131 W CH" b2="138 KV" b3="L14403CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="138 KV" b3="L14403CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="14403" b2="138 KV" b3="14403 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="144 WAYN" b2="138 KV" b3="14403 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="14403" b2="138 KV" b3="14403 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="14403" b2="138 KV" b3="14403 6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="138 KV" b3="L14403CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W502" b2="138 KV" b3="252-1 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="W503" b2="138 KV" b3="252-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28510</SeqNum>
    <Name>L138.Wayne-WestChicago.14405 (SPOG 3-30)</Name>
    <LastEdit Timestamp="2025-11-03T14:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="131 W CH" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="131 W CH" b2="138 KV" b3="L14405CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="138 KV" b3="L14405CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="14405" b2="138 KV" b3="14405 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="144 WAYN" b2="138 KV" b3="14405 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="14405" b2="138 KV" b3="14405 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="14405" b2="138 KV" b3="14405 6" />
      <ContingencyEquipment Action="S" Type="SD" b1="14405" b2="138 KV" b3="14405_5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="138 KV" b3="L14405CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W503" b2="138 KV" b3="252-1 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="W503" b2="138 KV" b3="252-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28520</SeqNum>
    <Name>L138.Calumet-River.15001</Name>
    <LastEdit Timestamp="2026-04-02T09:30:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="150 CALU" b2="138 KV" b3="L15001CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="150 CALU" b2="138 KV" b3="15001 A" />
      <ContingencyEquipment Action="L" Type="LN" b1="15001" b2="138 KV" b3="15001 B" />
      <ContingencyEquipment Action="L" Type="LN" b1="15001" b2="138 KV" b3="15001 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="955 RIVE" b2="138 KV" b3="L15001CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FINKSTL" b2="138 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28530</SeqNum>
    <Name>L138.Calumet-River.15002</Name>
    <LastEdit Timestamp="2026-04-03T09:42:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="150 CALU" b2="138 KV" b3="L15002CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="150 CALU" b2="138 KV" b3="15002 A" />
      <ContingencyEquipment Action="L" Type="LN" b1="15002" b2="138 KV" b3="15002 B" />
      <ContingencyEquipment Action="L" Type="LN" b1="15002" b2="138 KV" b3="15002 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="955 RIVE" b2="138 KV" b3="L15002CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FINKSTL" b2="138 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28550</SeqNum>
    <Name>L138.153Taylor-45Jefferson.15302</Name>
    <LastEdit Timestamp="2025-11-10T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="45 JEFFE" b2="138 KV" b3="15302" />
      <ContingencyEquipment Action="S" Type="SD" b1="153 TAYL" b2="138 KV" b3="15302 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT7-12CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT3-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28560</SeqNum>
    <Name>L138.153Taylor-45Jefferson.15303</Name>
    <LastEdit Timestamp="2026-01-06T11:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="45 JEFFE" b2="138 KV" b3="15303" />
      <ContingencyEquipment Action="S" Type="SD" b1="153 TAYL" b2="138 KV" b3="15303 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT1-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="L15303CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28570</SeqNum>
    <Name>L138.Taylor-Sears.15306</Name>
    <LastEdit Timestamp="2026-04-03T10:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="153 TAYL" b2="138 KV" b3="15306" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT2223CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT3-22CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="784 SEAR" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28580</SeqNum>
    <Name>L138.153Taylor-68Lasalle-126State.15315</Name>
    <LastEdit Timestamp="2025-06-19T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="68 LASAL" b2="138 KV" b3="15315 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="126 STAT" b2="138 KV" b3="BT4-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="126 STAT" b2="138 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="68 LASAL" b2="138 KV" b3="15315 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT4-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT9-28CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="68 LASAL" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28590</SeqNum>
    <Name>L138.153Taylor-68Lasalle.15316</Name>
    <LastEdit Timestamp="2025-06-19T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="68 LASAL" b2="138 KV" b3="15316" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT2930CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT3031CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="68 LASAL" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28600</SeqNum>
    <Name>L138.153Taylor-68Lasalle-126State.15317</Name>
    <LastEdit Timestamp="2025-06-19T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="68 LASAL" b2="138 KV" b3="15317 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="126 STAT" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="126 STAT" b2="138 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="68 LASAL" b2="138 KV" b3="15317 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT3-22CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="68 LASAL" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28610</SeqNum>
    <Name>L138.Taylor-Lasalle.15318</Name>
    <LastEdit Timestamp="2025-02-26T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="68 LASAL" b2="138 KV" b3="15318" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT2324CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT2425CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="68 LASAL" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28620</SeqNum>
    <Name>L138.155Nelson-15507-107Dixon.15507</Name>
    <LastEdit Timestamp="2025-06-19T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="107 DIXO" b2="138 KV" b3="15507 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="107 DIXO" b2="138 KV" b3="L15507CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="155 NELS" b2="138 KV" b3="15507 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="138 KV" b3="L15507CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="15507" b2="138 KV" b3="15507 Z2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="317 DIXO" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="317 DIXO" b2="138 KV" b3="L15507CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28630</SeqNum>
    <Name>L138.155Nelson-107Dixon-317Dixon.15508</Name>
    <LastEdit Timestamp="2025-07-11T13:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="107 DIXO" b2="138 KV" b3="L15508CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="138 KV" b3="L15508CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="155 NELS" b2="138 KV" b3="15508 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="15508" b2="138 KV" b3="15508 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="15508" b2="138 KV" b3="15508 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="107 DIXO" b2="138 KV" b3="15508 Z3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="317 DIXO" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="317 DIXO" b2="138 KV" b3="L15508CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28640</SeqNum>
    <Name>L138.155Nelson-133Rock.15509</Name>
    <LastEdit Timestamp="2024-06-12T14:17:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="155 NELS" b2="138 KV" b3="15509" />
      <ContingencyEquipment Action="OP" Type="CB" b1="133 ROCK" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="133 ROCK" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="133 ROCK" b2="34.5 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="133 ROCK" b2="34.5 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="138 KV" b3="L15509CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28660</SeqNum>
    <Name>L138.155Nelson-15518-133RockFall.15518</Name>
    <LastEdit Timestamp="2025-03-14T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="132 GARD" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="132 GARD" b2="138 KV" b3="TR76 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="133 ROCK" b2="34.5 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="133 ROCK" b2="34.5 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="133 ROCK" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="133 ROCK" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="133 ROCK" b2="138 KV" b3="TR76 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="138 KV" b3="L15518CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="15518" b2="138 KV" b3="15518 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="15518" b2="138 KV" b3="15518 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="15518" b2="138 KV" b3="15518 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="15518" b2="138 KV" b3="15518 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="15518" b2="138 KV" b3="15518 5" />
      <ContingencyEquipment Action="CL" Type="CB" b1="H71" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H71" b2="138 KV" b3="L15518CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28670</SeqNum>
    <Name>L138.CherryValley-StillmanValley.15621</Name>
    <LastEdit Timestamp="2025-06-20T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="156 CHER" b2="138 KV" b3="15621 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="138 KV" b3="L15621CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="176 STIL" b2="138 KV" b3="156107CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="176 STIL" b2="34.5 KV" b3="TR77 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="176 STIL" b2="138 KV" b3="TR77_34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28680</SeqNum>
    <Name>L138.CherryValley-15622-Sabrooke.15622</Name>
    <LastEdit Timestamp="2026-04-03T09:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="156 CHER" b2="138 KV" b3="15622 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="138 KV" b3="L15622CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="194 SABR" b2="138 KV" b3="15622 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="387 BLAC" b2="138 KV" b3="15622 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="138 KV" b3="L15622CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="387 BLAC" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="387 BLAC" b2="138 KV" b3="L15622CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28690</SeqNum>
    <Name>L138.156CherryValley-15623-122Belvidere.15623</Name>
    <LastEdit Timestamp="2024-12-12T14:04:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="122 BELV" b2="138 KV" b3="15623 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="122 BELV" b2="138 KV" b3="15623 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="122 BELV" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="122 BELV" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="122 BELV" b2="138 KV" b3="TR76 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="122 BELV" b2="34.5 KV" b3="TR76 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="138 KV" b3="L15623CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="156 CHER" b2="138 KV" b3="15623 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="160 ALPI" b2="138 KV" b3="15623 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="15623" b2="138 KV" b3="15623 6" />
      <ContingencyEquipment Action="S" Type="SD" b1="15623" b2="138 KV" b3="15623 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="160 ALPI" b2="138 KV" b3="15623 5" />
      <ContingencyEquipment Action="S" Type="SD" b1="160 ALPI" b2="138 KV" b3="15623 Z1" />
      <ContingencyEquipment Action="S" Type="SD" b1="160 ALPI" b2="138 KV" b3="15623 Z2" />
      <ContingencyEquipment Action="S" Type="SD" b1="160 ALPI" b2="138 KV" b3="15623 Z3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="160 ALPI" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="160 ALPI" b2="138 KV" b3="L15623CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="160 ALPI" b2="138 KV" b3="TR76 69" />
      <ContingencyEquipment Action="OP" Type="CB" b1="160 ALPI" b2="69 KV" b3="TR76 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="380 CHAR" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="380 CHAR" b2="138 KV" b3="L15623CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="389 E RO" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="389 E RO" b2="138 KV" b3="L15623CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="B465" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="B465" b2="138 KV" b3="L15623CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28710</SeqNum>
    <Name>L138.CherryValley-15625-Alpine.15625</Name>
    <LastEdit Timestamp="2026-04-03T09:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="138 KV" b3="L15625CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="156 CHER" b2="138 KV" b3="15625 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="15625" b2="138 KV" b3="15625 10" />
      <ContingencyEquipment Action="L" Type="LN" b1="15625" b2="138 KV" b3="15625 11" />
      <ContingencyEquipment Action="S" Type="SD" b1="15625" b2="138 KV" b3="15625 12" />
      <ContingencyEquipment Action="S" Type="SD" b1="15625" b2="138 KV" b3="15625 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="15625" b2="138 KV" b3="15625 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="171 WEMP" b2="138 KV" b3="15625 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="15625" b2="138 KV" b3="15625 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="15625" b2="138 KV" b3="15625 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="15625" b2="138 KV" b3="15625 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="163 ROSC" b2="138 KV" b3="15625 8" />
      <ContingencyEquipment Action="S" Type="SD" b1="15625" b2="138 KV" b3="15625 9" />
      <ContingencyEquipment Action="L" Type="LN" b1="160 ALPI" b2="138 KV" b3="15625 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="15625" b2="138 KV" b3="15625 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="388 HARL" b2="138 KV" b3="15625 Z3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="160 ALPI" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="160 ALPI" b2="138 KV" b3="L15625CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="163 ROSC" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="163 ROSC" b2="138 KV" b3="L15625CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="163 ROSC" b2="138 KV" b3="TR77 69" />
      <ContingencyEquipment Action="OP" Type="CB" b1="163 ROSC" b2="69 KV" b3="TR77 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="164 SAND" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="164 SAND" b2="138 KV" b3="L15625CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="171 WEMP" b2="138 KV" b3="L15625CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="380 CHAR" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="380 CHAR" b2="138 KV" b3="L15625CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="388 HARL" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="389 E RO" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="389 E RO" b2="138 KV" b3="L15625CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="391 ARGY" b2="138 KV" b3="15625 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="391 ARGY" b2="138 KV" b3="BT1-2 D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28720</SeqNum>
    <Name>L138.CherryValley-15626-Sabrooke.15626</Name>
    <LastEdit Timestamp="2026-04-03T09:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="156 CHER" b2="138 KV" b3="15626 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="138 KV" b3="L15626CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="194 SABR" b2="138 KV" b3="15626 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="387 BLAC" b2="138 KV" b3="15626 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="138 KV" b3="L15626CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="387 BLAC" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="387 BLAC" b2="138 KV" b3="L15626CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28730</SeqNum>
    <Name>L138.CherryValley-Gildden.15627</Name>
    <LastEdit Timestamp="2025-10-09T11:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="156 CHER" b2="138 KV" b3="15627 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="138 KV" b3="L15627CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="15627" b2="138 KV" b3="15627 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="83 GLIDD" b2="138 KV" b3="15627_3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="83 GLIDD" b2="138 KV" b3="BT3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="83 GLIDD" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="B200" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28740</SeqNum>
    <Name>L138.159Northbrook-15912-48Highland.15912</Name>
    <LastEdit Timestamp="2024-12-12T11:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="15912" b2="138 KV" b3="15912 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="159 NORT" b2="138 KV" b3="L15912CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="48 HIGHL" b2="138 KV" b3="15912 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="15912" b2="138 KV" b3="15912 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="15912" b2="138 KV" b3="15912 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="15912" b2="138 KV" b3="15912 5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="212 NORT" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="212 NORT" b2="138 KV" b3="L15912CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="213 DEER" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="213 DEER" b2="138 KV" b3="L15912CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="48 HIGHL" b2="138 KV" b3="L15912" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28750</SeqNum>
    <Name>138/34.48Highland.TR77</Name>
    <LastEdit Timestamp="2024-11-06T12:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="48 HIGHL" b2="138 KV" b3="TR77 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="48 HIGHL" b2="34.5 KV" b3="TR77 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="48 HIGHL" b2="138 KV" b3="TR77 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28760</SeqNum>
    <Name>L138.171Wempletown-17105-163RoscoeBert.17105</Name>
    <LastEdit Timestamp="2024-12-12T13:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="122 BELV" b2="138 KV" b3="0507CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="163 ROSC" b2="138 KV" b3="17105 7" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="163 ROSC" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="163 ROSC" b2="138 KV" b3="L17105CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="164 SAND" b2="138 KV" b3="17105 6" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="164 SAND" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="164 SAND" b2="138 KV" b3="L17105CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="171 WEMP" b2="138 KV" b3="L17105CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="171 WEMP" b2="138 KV" b3="17105 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="17105" b2="138 KV" b3="17105 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="122 BELV" b2="138 KV" b3="17105 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="17105" b2="138 KV" b3="17105 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="17105" b2="138 KV" b3="17105 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="388 HARL" b2="138 KV" b3="17105 Z2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="388 HARL" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="391 ARGY" b2="138 KV" b3="17105 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="17105" b2="138 KV" b3="17105 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="391 ARGY" b2="138 KV" b3="BT1-2 D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28770</SeqNum>
    <Name>L138.Harbor-University.17008</Name>
    <LastEdit Timestamp="2025-10-10T13:04:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="170 HARB" b2="138 KV" b3="17008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="170 HARB" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="P" Type="XF" b1="170 HARB" b2="138 KV" b3="P17008" />
      <ContingencyEquipment Action="X" Type="XF" b1="170 HARB" b2="138 KV" b3="P1700838" />
      <ContingencyEquipment Action="X" Type="XF" b1="170 HARB" b2="138 KV" b3="Z1700838" />
      <ContingencyEquipment Action="OP" Type="CB" b1="174 UNIV" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="174 UNIV" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28780</SeqNum>
    <Name>L138.171Wempletown-17113-194Sabrooke.17113</Name>
    <LastEdit Timestamp="2025-10-09T11:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="162 PIER" b2="138 KV" b3="17113 5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="162 PIER" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="162 PIER" b2="138 KV" b3="L17113CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="171 WEMP" b2="138 KV" b3="L17113CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="194 SABR" b2="138 KV" b3="17113 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="171 WEMP" b2="138 KV" b3="17113_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="138 KV" b3="L17113CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28790</SeqNum>
    <Name>L138.Wempletown-Lancaster.17121</Name>
    <LastEdit Timestamp="2026-04-03T10:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="119 LANC" b2="138 KV" b3="L17121CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="171 WEMP" b2="138 KV" b3="17121 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="171 WEMP" b2="138 KV" b3="L17121CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="119 LANC" b2="138 KV" b3="17121 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="17121" b2="138 KV" b3="17121 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="386 PECA" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28810</SeqNum>
    <Name>L138.177Burnham-17712-73ChicagoHeights.17712</Name>
    <LastEdit Timestamp="2024-12-17T15:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="177 BURN" b2="138 KV" b3="17712 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="138 KV" b3="L17712CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="17712" b2="138 KV" b3="17712 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="73 CHI H" b2="138 KV" b3="17712 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="17712" b2="138 KV" b3="17712 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="17712" b2="138 KV" b3="17712 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="17712" b2="138 KV" b3="17712 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="447 SANR" b2="138 KV" b3="17712 Z3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="446 LANS" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="447 SANR" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="458 GREE" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="73 CHI H" b2="138 KV" b3="L17712CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28820</SeqNum>
    <Name>L138.Burnham-17713-Wildwood.17713</Name>
    <LastEdit Timestamp="2026-04-06T09:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="177 BURN" b2="138 KV" b3="17713 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="138 KV" b3="L17713CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="43 WILDW" b2="138 KV" b3="17713 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="17713" b2="138 KV" b3="17713 5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="43 WILDW" b2="138 KV" b3="BT1-4 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="43 WILDW" b2="138 KV" b3="TR74_12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="Z524" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="Z524" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28840</SeqNum>
    <Name>L138.Burnham-17715.17715</Name>
    <LastEdit Timestamp="2026-04-06T09:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="177 BURN" b2="138 KV" b3="17715" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="138 KV" b3="17715 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="Z100" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="Z100" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28850</SeqNum>
    <Name>L138.Bloom-17903-Matteson</Name>
    <LastEdit Timestamp="2025-01-09T14:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="127 MATT" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="127 MATT" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="179 BLOO" b2="138 KV" b3="17903 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="179 BLOO" b2="138 KV" b3="L17903CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="127 MATT" b2="138 KV" b3="17903 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="457 PK F" b2="138 KV" b3="17903 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="457 PK F" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="CL" Type="CB" b1="66 E FRN" b2="138 KV" b3="BT2-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28860</SeqNum>
    <Name>L138.Bloom-17904-Matteson.17904</Name>
    <LastEdit Timestamp="2026-04-06T09:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="127 MATT" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="127 MATT" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="127 MATT" b2="138 KV" b3="TR78 34" />
      <ContingencyEquipment Action="L" Type="LN" b1="179 BLOO" b2="138 KV" b3="17904 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="179 BLOO" b2="138 KV" b3="L17904CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="127 MATT" b2="138 KV" b3="17904 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="457 PK F" b2="138 KV" b3="17904 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="457 PK F" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28870</SeqNum>
    <Name>L138.Tollway-18505-Hoffman.18505 </Name>
    <LastEdit Timestamp="2026-05-08T14:00:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="185 TOLL" b2="138 KV" b3="L18505CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="185 TOLL" b2="138 KV" b3="18505 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="235 POPL" b2="138 KV" b3="18505 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="18505" b2="138 KV" b3="18505_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="214 HOFF" b2="138 KV" b3="L18505_M" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="235 POPL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="235 POPL" b2="138 KV" b3="L18505CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28880</SeqNum>
    <Name>L138.Tollway-18506-Poplar-Hoffman.18506</Name>
    <LastEdit Timestamp="2026-05-08T13:51:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="185 TOLL" b2="138 KV" b3="L18506CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="185 TOLL" b2="138 KV" b3="18506 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="235 POPL" b2="138 KV" b3="18506 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="18506" b2="138 KV" b3="18506_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="10-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="11-12" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="235 POPL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="235 POPL" b2="138 KV" b3="L18506CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28890</SeqNum>
    <Name>L138.Tollway-18512-Dundee.18512 + RockyRoad.CT4</Name>
    <LastEdit Timestamp="2026-04-06T09:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="185 TOLL" b2="138 KV" b3="L18512CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="185 TOLL" b2="138 KV" b3="18512 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="260 DUND" b2="138 KV" b3="18512 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="18512" b2="138 KV" b3="18512 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="260 DUND" b2="138 KV" b3="13806CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="932 ROCK" b2="138 KV" b3="L18512CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="932 ROCK" b2="12 KV" b3="RR-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="932 ROCK" b2="138 KV" b3="TR34 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28900</SeqNum>
    <Name>L138.Tollway-18513-Dundee.18513 + RockyRoad.CT1-3</Name>
    <LastEdit Timestamp="2026-04-06T09:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="185 TOLL" b2="138 KV" b3="L18513CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="185 TOLL" b2="138 KV" b3="18513 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="260 DUND" b2="138 KV" b3="18513 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="18513" b2="138 KV" b3="18513 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="260 DUND" b2="138 KV" b3="13805CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="260 DUND" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="932 ROCK" b2="138 KV" b3="L18513CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="932 ROCK" b2="12 KV" b3="RR-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="932 ROCK" b2="12 KV" b3="RR-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="932 ROCK" b2="12 KV" b3="RR-3" />
      <ContingencyEquipment Action="X" Type="XF" b1="932 ROCK" b2="138 KV" b3="TR31 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="932 ROCK" b2="138 KV" b3="TR32 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="932 ROCK" b2="138 KV" b3="TR33 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28910</SeqNum>
    <Name>L138.Steward-H445.18618</Name>
    <LastEdit Timestamp="2025-04-18T17:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="H445" b2="138 KV" b3="18618 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="186 STEW" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="186 STEW" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H445" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H445" b2="138 KV" b3="BT2-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28920</SeqNum>
    <Name>L138.192Ridgeland-505OakPark.19209</Name>
    <LastEdit Timestamp="2025-10-09T12:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="505 OAK" b2="138 KV" b3="19209" />
      <ContingencyEquipment Action="OP" Type="CB" b1="192 RIDG" b2="138 KV" b3="BT1-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="192 RIDG" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="P" Type="XF" b1="192 RIDG" b2="138 KV" b3="P19209-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="192 RIDG" b2="138 KV" b3="S1920938" />
      <ContingencyEquipment Action="X" Type="XF" b1="192 RIDG" b2="138 KV" b3="Y1920938" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="505 OAK" b2="138 KV" b3="BT1-6 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="505 OAK" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="505 OAK" b2="138 KV" b3="BT5-6 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28930</SeqNum>
    <Name>L138.McCook-D467(Electromotive).5101</Name>
    <LastEdit Timestamp="2026-04-06T09:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5101 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="51 MC CO" b2="138 KV" b3="5101" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="D467" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="D467" b2="138 KV" b3="TR72 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28940</SeqNum>
    <Name>L138.McCook-D467(Electromotive).5102</Name>
    <LastEdit Timestamp="2026-04-06T09:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="51 MC CO" b2="138 KV" b3="5102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5102 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="D467" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="D467" b2="138 KV" b3="TR71 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28950</SeqNum>
    <Name>L138.Sabrooke-19414-Lancaster-Freeport.19414</Name>
    <LastEdit Timestamp="2024-11-18T13:11:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="119 LANC" b2="138 KV" b3="L19414" />
      <ContingencyEquipment Action="OP" Type="CB" b1="121 FREE" b2="138 KV" b3="BT1-5 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="121 FREE" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="121 FREE" b2="138 KV" b3="BT4-5 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="162 PIER" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="162 PIER" b2="138 KV" b3="L19414CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="165 FORD" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="138 KV" b3="L19414CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="194 SABR" b2="138 KV" b3="19414 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="19414" b2="138 KV" b3="19414 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="121 FREE" b2="138 KV" b3="19414 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="19414" b2="138 KV" b3="19414 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="19414" b2="138 KV" b3="19414 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="165 FORD" b2="138 KV" b3="19414 6" />
      <ContingencyEquipment Action="S" Type="SD" b1="19414" b2="138 KV" b3="19414 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="19414" b2="138 KV" b3="19414 8" />
      <ContingencyEquipment Action="S" Type="SD" b1="19414" b2="138 KV" b3="19414 9" />
      <ContingencyEquipment Action="L" Type="LN" b1="162 PIER" b2="138 KV" b3="19414 Z1" />
      <ContingencyEquipment Action="L" Type="LN" b1="19414" b2="138 KV" b3="19414 Z2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="390 SO P" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="B427" b2="138 KV" b3="L11902CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="B427" b2="138 KV" b3="L19414CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28960</SeqNum>
    <Name>L138.198DesPlaines-648Norridge.19801</Name>
    <LastEdit Timestamp="2025-10-28T11:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="648 NORR" b2="138 KV" b3="19801" />
      <ContingencyEquipment Action="S" Type="SD" b1="198 DESP" b2="138 KV" b3="19801 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="198 DESP" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="198 DESP" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="648 NORR" b2="138 KV" b3="BT723 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="648 NORR" b2="138 KV" b3="BT745 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="648 NORR" b2="138 KV" b3="BT756 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28970</SeqNum>
    <Name>L138.282Zion-Lakeview.28201 (Tie)</Name>
    <LastEdit Timestamp="2026-05-08T13:46:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="282 ZION" b2="138 KV" b3="28201" />
      <ContingencyEquipment Action="OP" Type="CB" b1="282 ZION" b2="138 KV" b3="BT" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="282 ZION" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="282 ZION" b2="138 KV" b3="L28201CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEVIE2" b2="138 KV" b3="9386" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28980</SeqNum>
    <Name>951Aurora.CT5-10</Name>
    <LastEdit Timestamp="2026-04-06T09:06:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="951 AURO" b2="138 KV" b3="95102 Z1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="951 AURO" b2="13.5 KV" b3="AR-10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="951 AURO" b2="13.5 KV" b3="AR-5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="951 AURO" b2="13.5 KV" b3="AR-6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="951 AURO" b2="13.5 KV" b3="AR-7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="951 AURO" b2="13.5 KV" b3="AR-8" />
      <ContingencyEquipment Action="U" Type="GEN" b1="951 AURO" b2="13.5 KV" b3="AR-9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="951 AURO" b2="13.5 KV" b3="AR5LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="951 AURO" b2="13.5 KV" b3="AR6LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="138 KV" b3="L11103CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="138 KV" b3="L14403CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="138 KV" b3="L95102CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="951 AURO" b2="138 KV" b3="TR10 13" />
      <ContingencyEquipment Action="X" Type="XF" b1="951 AURO" b2="138 KV" b3="TR5 13" />
      <ContingencyEquipment Action="X" Type="XF" b1="951 AURO" b2="138 KV" b3="TR6 13" />
      <ContingencyEquipment Action="X" Type="XF" b1="951 AURO" b2="138 KV" b3="TR7 13" />
      <ContingencyEquipment Action="X" Type="XF" b1="951 AURO" b2="138 KV" b3="TR8 13" />
      <ContingencyEquipment Action="X" Type="XF" b1="951 AURO" b2="138 KV" b3="TR9 13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>28990</SeqNum>
    <Name>951Aurora.CT3-4</Name>
    <LastEdit Timestamp="2026-04-03T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="951 AURO" b2="138 KV" b3="95103 Z1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="951 AURO" b2="18 KV" b3="AR-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="951 AURO" b2="18 KV" b3="AR-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="951 AURO" b2="18 KV" b3="ATR3 04" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="138 KV" b3="L11105CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="138 KV" b3="L14405CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="138 KV" b3="L95103CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="951 AURO" b2="138 KV" b3="TR3 18" />
      <ContingencyEquipment Action="X" Type="XF" b1="951 AURO" b2="138 KV" b3="TR4 18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="18 KV" b3="UAR-3CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="18 KV" b3="UAR-4CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29000</SeqNum>
    <Name>L138.Sabrooke-Rockford.95201 + 952Rockford.CT11&amp;12</Name>
    <LastEdit Timestamp="2026-04-03T10:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="194 SABR" b2="138 KV" b3="95201" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="138 KV" b3="L95201CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="952 ROCK" b2="16 KV" b3="RO11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="952 ROCK" b2="16 KV" b3="RO12" />
      <ContingencyEquipment Action="X" Type="XF" b1="952 ROCK" b2="138 KV" b3="TR11 16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="952 ROCK" b2="138 KV" b3="TR11 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="952 ROCK" b2="138 KV" b3="TR12 16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="952 ROCK" b2="138 KV" b3="TR12 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29030</SeqNum>
    <Name>L138.960Elgin-79Spaulding.96001 + Elgin.U1&amp;U2</Name>
    <LastEdit Timestamp="2025-07-01T12:04:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="79 SPAUL" b2="138 KV" b3="96001" />
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="138 KV" b3="L96001CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="960 ELGI" b2="138 KV" b3="BLUE CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="960 ELGI" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="960 ELGI" b2="13.5 KV" b3="EE-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="960 ELGI" b2="13.5 KV" b3="EE-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="960 ELGI" b2="138 KV" b3="TR1 13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="960 ELGI" b2="138 KV" b3="TR1 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="960 ELGI" b2="138 KV" b3="TR2 13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="960 ELGI" b2="138 KV" b3="TR2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29040</SeqNum>
    <Name>L138.960Elgin-79Spaulding.96002 + Elgin.U3&amp;U4</Name>
    <LastEdit Timestamp="2025-07-01T12:08:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="79 SPAUL" b2="138 KV" b3="96002" />
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="138 KV" b3="L96002CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="960 ELGI" b2="138 KV" b3="ATRREDCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="960 ELGI" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="960 ELGI" b2="13.5 KV" b3="EE-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="960 ELGI" b2="13.5 KV" b3="EE-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="960 ELGI" b2="138 KV" b3="TR3 13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="960 ELGI" b2="138 KV" b3="TR3 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="960 ELGI" b2="138 KV" b3="TR4 13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="960 ELGI" b2="138 KV" b3="TR4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29050</SeqNum>
    <Name>230/138.Monocacy.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-10T15:37:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MONOCACY" b2="230 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONOCACY" b2="138 KV" b3="T4 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MONOCACY" b2="230 KV" b3="T4 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29060</SeqNum>
    <Name>L345.Chamberlin-Harding</Name>
    <LastEdit Timestamp="2026-04-06T09:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="345 KV" b3="B210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="345 KV" b3="B87" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAMBROE" b2="345 KV" b3="CHA-HAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B32" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29070</SeqNum>
    <Name>L345.Juniper-Star</Name>
    <LastEdit Timestamp="2025-09-02T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="226" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="232" />
      <ContingencyEquipment Action="L" Type="LN" b1="STAR_FE" b2="345 KV" b3="STA-JUN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29080</SeqNum>
    <Name>L345.Hanna-Juniper</Name>
    <LastEdit Timestamp="2026-01-06T11:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B194" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B197" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B35" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B36" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANNAOE" b2="345 KV" b3="HAN-JUN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29090</SeqNum>
    <Name>L345.BeaverValley-Hanna.320</Name>
    <LastEdit Timestamp="2025-08-22T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="320-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="320-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAV DUQ" b2="345 KV" b3="BEA-HAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B108" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B109" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29100</SeqNum>
    <Name>Perry.U1</Name>
    <LastEdit Timestamp="2025-08-25T13:37:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="LDD" Type="LOAD" b1="PERRY_FE" b2="345 KV" b3="LD100" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PERRY_FE" b2="22 KV" b3="LD110B" />
      <ContingencyEquipment Action="LDD" Type="LOAD" b1="PERRY_FE" b2="345 KV" b3="LD200" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PERRY_FE" b2="22 KV" b3="PR10" />
      <ContingencyEquipment Action="X" Type="XF" b1="PERRY_FE" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29120</SeqNum>
    <Name>DavisBesse.U1</Name>
    <LastEdit Timestamp="2025-04-30T03:32:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B34560" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B34561" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DAVISBES" b2="25 KV" b3="DB10" />
      <ContingencyEquipment Action="LDD" Type="LOAD" b1="DAVISBES" b2="345 KV" b3="TR01" />
      <ContingencyEquipment Action="LDD" Type="LOAD" b1="DAVISBES" b2="345 KV" b3="TR02" />
      <ContingencyEquipment Action="X" Type="XF" b1="DAVISBES" b2="345 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAVISBES" b2="25 KV" b3="TR11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29130</SeqNum>
    <Name>Lakeshore.SVC</Name>
    <LastEdit Timestamp="2025-02-20T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESHOR" b2="138 KV" b3="B500" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LAKESHOR" b2="138 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29140</SeqNum>
    <Name>230/138.SouthAkron.T7</Name>
    <LastEdit Timestamp="2024-09-23T11:18:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SAKRON" b2="230 KV" b3="7" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SAKRON" b2="230 KV" b3="CAP3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="CAP_3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="LAUS3_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="LAUS4_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="MLWD_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="SMAN_4-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="TRAN5_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="138 KV" b3="TRAN_7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29160</SeqNum>
    <Name>230/138.SouthAkron.T6</Name>
    <LastEdit Timestamp="2024-09-23T11:18:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SAKRON" b2="230 KV" b3="6" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SAKRON" b2="230 KV" b3="CAP4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="CAP4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="LAUS3_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="LAUS4_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="MLWD_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="SMAN_4-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="TRAN5_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="138 KV" b3="TRAN_6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29170</SeqNum>
    <Name>L345.CliftyCreek-Pierce.1</Name>
    <LastEdit Timestamp="2026-04-03T10:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="PIERCE" b2="345 KV" b3="PIE-CLI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCE" b2="345 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCE" b2="345 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29180</SeqNum>
    <Name>L345.CliftyCreek-Trimblec</Name>
    <LastEdit Timestamp="2026-04-06T09:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="DL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="DL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="4512_42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="BTC_4542" />
      <ContingencyEquipment Action="S" Type="SD" b1="TRMBL_LG" b2="345 KV" b3="REACTOR" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRMBL_LG" b2="345 KV" b3="TRI-CLI1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29190</SeqNum>
    <Name>L345.CliftyCreek-Pierce.2</Name>
    <LastEdit Timestamp="2026-04-03T10:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="PIERCE" b2="345 KV" b3="PIE-CLI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCE" b2="345 KV" b3="I" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCE" b2="345 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29200</SeqNum>
    <Name>L345.CliftyCreek-Dearborn</Name>
    <LastEdit Timestamp="2026-04-03T10:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLIFTYCR" b2="345 KV" b3="CLI-DEA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEARBORN" b2="345 KV" b3="DB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29210</SeqNum>
    <Name>230/69.Lyons.3BK</Name>
    <LastEdit Timestamp="2026-04-03T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LYONS" b2="230 KV" b3="3 BK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYONS" b2="230 KV" b3="B371CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYONS" b2="69 KV" b3="B372" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYONS" b2="230 KV" b3="B79" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29220</SeqNum>
    <Name>CliftyCreek.U1</Name>
    <LastEdit Timestamp="2026-04-06T09:07:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLIFTYCR" b2="15.5 KV" b3="CC1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLIFTYCR" b2="345 KV" b3="GSU1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLIFTYCR" b2="15.5 KV" b3="SS1 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29230</SeqNum>
    <Name>CliftyCreek.U2</Name>
    <LastEdit Timestamp="2026-04-06T09:07:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLIFTYCR" b2="15.5 KV" b3="CC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="F" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLIFTYCR" b2="345 KV" b3="GSU2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLIFTYCR" b2="15.5 KV" b3="SS2 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29240</SeqNum>
    <Name>CliftyCreek.U3</Name>
    <LastEdit Timestamp="2026-04-06T09:08:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLIFTYCR" b2="15.5 KV" b3="CC3" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLIFTYCR" b2="345 KV" b3="GSU3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="I" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLIFTYCR" b2="15.5 KV" b3="SS3 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29250</SeqNum>
    <Name>CliftyCreek.U4</Name>
    <LastEdit Timestamp="2026-04-06T09:08:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLIFTYCR" b2="15.5 KV" b3="CC4" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLIFTYCR" b2="345 KV" b3="GSU4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLIFTYCR" b2="15.5 KV" b3="SS4 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29260</SeqNum>
    <Name>CliftyCreek.U5</Name>
    <LastEdit Timestamp="2026-04-06T09:09:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLIFTYCR" b2="15.5 KV" b3="CC5" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLIFTYCR" b2="345 KV" b3="GSU5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="O" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLIFTYCR" b2="15.5 KV" b3="SS5 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29270</SeqNum>
    <Name>CliftyCreek.U6</Name>
    <LastEdit Timestamp="2026-04-06T09:09:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLIFTYCR" b2="15.5 KV" b3="CC6" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLIFTYCR" b2="345 KV" b3="GSU6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="Q" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLIFTYCR" b2="15.5 KV" b3="SS6 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29280</SeqNum>
    <Name>345/138.CliftyCreek.100A</Name>
    <LastEdit Timestamp="2025-07-11T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CLIFTYCR" b2="345 KV" b3="100A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="138 KV" b3="AC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="138 KV" b3="AD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="138 KV" b3="AE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="P" />
      <ContingencyEquipment Action="S" Type="SD" b1="CLIFTYCR" b2="138 KV" b3="REACTOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29290</SeqNum>
    <Name>L138.CliftyCreek-Northside</Name>
    <LastEdit Timestamp="2026-04-03T09:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLIFTYCR" b2="138 KV" b3="804 DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="138 KV" b3="AC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_SIDE" b2="138 KV" b3="BNS_3816" />
      <ContingencyEquipment Action="L" Type="LN" b1="N_SIDE" b2="138 KV" b3="NOR-CLI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_SIDE" b2="138 KV" b3="NS_3816E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29310</SeqNum>
    <Name>L138.CliftyCreek-Carrolton</Name>
    <LastEdit Timestamp="2026-04-03T09:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARROLTO" b2="138 KV" b3="B067_744" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARROLTO" b2="138 KV" b3="B067_747" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARROLTO" b2="138 KV" b3="CAR-CLI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="138 KV" b3="AD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29320</SeqNum>
    <Name>L345.Dearborn-Pierce</Name>
    <LastEdit Timestamp="2024-12-16T17:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEARBORN" b2="345 KV" b3="DC" />
      <ContingencyEquipment Action="L" Type="LN" b1="PIERCE" b2="345 KV" b3="PIE-DEA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCE" b2="345 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCE" b2="345 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29330</SeqNum>
    <Name>L345.Buffington-CliftyCreek</Name>
    <LastEdit Timestamp="2026-04-06T09:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="345 KV" b3="1523" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="345 KV" b3="1525" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUFFINGT" b2="345 KV" b3="BUF-CLI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTYCR" b2="345 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29340</SeqNum>
    <Name>L345.DOEX530-Kygercre.1</Name>
    <LastEdit Timestamp="2026-04-06T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOEX530" b2="345 KV" b3="212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOEX530" b2="345 KV" b3="215" />
      <ContingencyEquipment Action="L" Type="LN" b1="KYGERCRE" b2="345 KV" b3="KYG-DOE3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29350</SeqNum>
    <Name>L345.DOEX530-Kygercre.2</Name>
    <LastEdit Timestamp="2026-04-06T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOEX530" b2="345 KV" b3="222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOEX530" b2="345 KV" b3="225" />
      <ContingencyEquipment Action="L" Type="LN" b1="KYGERCRE" b2="345 KV" b3="KYG-DOE4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29360</SeqNum>
    <Name>L345.DOEX530-Pierce.1</Name>
    <LastEdit Timestamp="2026-04-06T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOEX530" b2="345 KV" b3="242" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOEX530" b2="345 KV" b3="245" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOEX530" b2="345 KV" b3="DOE-PIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCE" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCE" b2="345 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29370</SeqNum>
    <Name>L345.DOEX530-Pierce.2</Name>
    <LastEdit Timestamp="2026-04-06T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOEX530" b2="345 KV" b3="252" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOEX530" b2="345 KV" b3="255" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOEX530" b2="345 KV" b3="DOE-PIE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCE" b2="345 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCE" b2="345 KV" b3="I" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29380</SeqNum>
    <Name>L345.KygerCreek-Pierce</Name>
    <LastEdit Timestamp="2026-04-06T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KYGERCRE" b2="345 KV" b3="KYG-PEI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCE" b2="345 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCE" b2="345 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29390</SeqNum>
    <Name>L345.Bayway-Linden.M-3465</Name>
    <LastEdit Timestamp="2025-06-02T10:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYWAY" b2="345 KV" b3="BAY-LIN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="345 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="345 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29410</SeqNum>
    <Name>138/69.IndustrialPark.TR1</Name>
    <LastEdit Timestamp="2025-06-25T12:08:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDUSTRI" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDUSTRI" b2="138 KV" b3="M004L2" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDUSTRI" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29420</SeqNum>
    <Name>L345.Pierce-Foster</Name>
    <LastEdit Timestamp="2025-10-14T18:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="345 KV" b3="1357" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="345 KV" b3="1359" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTER2" b2="345 KV" b3="FOS-PIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERC_DK" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERC_DK" b2="345 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29430</SeqNum>
    <Name>L345.Buffington-Pierce</Name>
    <LastEdit Timestamp="2025-10-14T18:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="345 KV" b3="1529" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="345 KV" b3="1531" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUFFINGT" b2="345 KV" b3="BUF-PIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERC_DK" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERC_DK" b2="345 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29440</SeqNum>
    <Name>KygerCreek.U1</Name>
    <LastEdit Timestamp="2026-04-08T11:06:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="X" Type="XF" b1="KYGERCRE" b2="345 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KYGERCRE" b2="15.5 KV" b3="KY1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KYGERCRE" b2="15.5 KV" b3="SS1 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29450</SeqNum>
    <Name>KygerCreek.U2</Name>
    <LastEdit Timestamp="2026-04-08T11:07:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="F" />
      <ContingencyEquipment Action="X" Type="XF" b1="KYGERCRE" b2="345 KV" b3="GSU2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KYGERCRE" b2="15.5 KV" b3="KY2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KYGERCRE" b2="15.5 KV" b3="SS2 LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="UN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29460</SeqNum>
    <Name>KygerCreek.U3</Name>
    <LastEdit Timestamp="2026-04-08T11:07:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="KYGERCRE" b2="345 KV" b3="GSU3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="I" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KYGERCRE" b2="15.5 KV" b3="KY3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KYGERCRE" b2="15.5 KV" b3="SS3 LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="UN3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29470</SeqNum>
    <Name>KygerCreek.U4</Name>
    <LastEdit Timestamp="2026-04-08T11:07:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="KYGERCRE" b2="345 KV" b3="GSU4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KYGERCRE" b2="15.5 KV" b3="KY4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KYGERCRE" b2="15.5 KV" b3="SS4 LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="UN4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29480</SeqNum>
    <Name>KygerCreek.U5</Name>
    <LastEdit Timestamp="2026-04-08T11:08:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="KYGERCRE" b2="345 KV" b3="GSU5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KYGERCRE" b2="15.5 KV" b3="KY5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="O" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KYGERCRE" b2="15.5 KV" b3="SS5 LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KYGERCRE" b2="345 KV" b3="UN5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29500</SeqNum>
    <Name>L345.BeaverValley-Clinton.314</Name>
    <LastEdit Timestamp="2026-04-07T09:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="314-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="314-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAV DUQ" b2="345 KV" b3="BEA-CLI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIN DUQ" b2="345 KV" b3="BEAV DUQ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29510</SeqNum>
    <Name>345/138.BeaverValley.T2-4</Name>
    <LastEdit Timestamp="2025-02-26T14:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BEAV DUQ" b2="345 KV" b3="2_4TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="2_4TIECB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="138 KV" b3="TIE2-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29530</SeqNum>
    <Name>BeaverValley.U1</Name>
    <LastEdit Timestamp="2024-10-16T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BEAV DUQ" b2="345 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEAV DUQ" b2="22 KV" b3="UNIT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="22 KV" b3="UNIT1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="UNIT13CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="UNIT14CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29540</SeqNum>
    <Name>BeaverValley.U2</Name>
    <LastEdit Timestamp="2024-10-16T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BEAV DUQ" b2="345 KV" b3="GSU2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEAV DUQ" b2="22 KV" b3="UNIT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="22 KV" b3="UNIT2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="UNIT25CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="UNIT26CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29550</SeqNum>
    <Name>L345.Crescent-Collier-BrunotIsland.331 </Name>
    <LastEdit Timestamp="2026-01-06T11:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNOTIS" b2="345 KV" b3="BR1-COL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="345 KV" b3="CRES331" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="331CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLLIER" b2="345 KV" b3="COL-CRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="331CB-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="331CB-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29570</SeqNum>
    <Name>345/138.Crescent.T1</Name>
    <LastEdit Timestamp="2026-04-07T08:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="BEAV1DUQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="MANSFIE1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRES DUQ" b2="345 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="T3-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29580</SeqNum>
    <Name>345/138.Crescent.T2</Name>
    <LastEdit Timestamp="2024-12-03T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="331CB-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="BEAV2DUQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="MANSFIE2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRES DUQ" b2="345 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="138 KV" b3="T2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="T3-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29590</SeqNum>
    <Name>L345.Clinton-Collier</Name>
    <LastEdit Timestamp="2026-01-08T08:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLIN DUQ" b2="345 KV" b3="CLI-COL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIN DUQ" b2="345 KV" b3="COLLIER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="324-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="324-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29600</SeqNum>
    <Name>345/138.Collier.T1</Name>
    <LastEdit Timestamp="2026-01-07T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="301-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="304-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="324-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="331CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLLIER" b2="345 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="T3-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29610</SeqNum>
    <Name>345/138.Collier.T2</Name>
    <LastEdit Timestamp="2026-01-07T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="301-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="304-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="324-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLLIER" b2="345 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="138 KV" b3="T2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="T3-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29620</SeqNum>
    <Name>345/138.Clinton(DUQU).T1</Name>
    <LastEdit Timestamp="2024-06-12T14:36:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIN DUQ" b2="345 KV" b3="BEAV DUQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIN DUQ" b2="345 KV" b3="COLLIER" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLIN DUQ" b2="345 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIN DUQ" b2="138 KV" b3="T1 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29630</SeqNum>
    <Name>L345.Arsenal-BrunotIsland.305</Name>
    <LastEdit Timestamp="2025-01-24T14:28:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARSENAL" b2="345 KV" b3="ARS-BRU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="345 KV" b3="TIE 1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="345 KV" b3="TIE 2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="345 KV" b3="ARS305CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29700</SeqNum>
    <Name>L138.Peters-USAP-WoodvilleDUQ.Z-117</Name>
    <LastEdit Timestamp="2025-10-15T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PETERS" b2="138 KV" b3="PET-USA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERS" b2="138 KV" b3="USAP" />
      <ContingencyEquipment Action="L" Type="LN" b1="USAP" b2="138 KV" b3="USA-WOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVILL" b2="138 KV" b3="USAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29800</SeqNum>
    <Name>Seward.U1</Name>
    <LastEdit Timestamp="2026-04-07T10:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="230 KV" b3="B6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SEWARD" b2="22 KV" b3="UNIT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29810</SeqNum>
    <Name>L345.EastBend-Terminal</Name>
    <LastEdit Timestamp="2024-10-18T14:03:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEND" b2="345 KV" b3="1579" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEND" b2="345 KV" b3="1583" />
      <ContingencyEquipment Action="L" Type="LN" b1="EBEND" b2="345 KV" b3="EBE-TER1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EBEND" b2="345 KV" b3="TB11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="345 KV" b3="1301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="345 KV" b3="1307" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29840</SeqNum>
    <Name>L500.PleasantView-GooseCreek.595</Name>
    <LastEdit Timestamp="2026-01-27T10:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRE" b2="500 KV" b3="514T595" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOOSECRE" b2="500 KV" b3="595" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRE" b2="500 KV" b3="59582" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="500 KV" b3="H322" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29850</SeqNum>
    <Name>L230.OtterCreek-Conastone.2302</Name>
    <LastEdit Timestamp="2025-08-26T17:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="2302 GCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="2310_02" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONASTON" b2="230 KV" b3="CNS-OTT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTCRKPL" b2="230 KV" b3="CONA-YRK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTCRKPL" b2="230 KV" b3="CONA2302" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29860</SeqNum>
    <Name>L230.Yorkana-OtterCreek</Name>
    <LastEdit Timestamp="2024-06-12T14:54:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTCRKPL" b2="230 KV" b3="CONA-YRK" />
      <ContingencyEquipment Action="L" Type="LN" b1="OTTCRKPL" b2="230 KV" b3="OTT-YOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTCRKPL" b2="230 KV" b3="YORK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="230 KV" b3="B02" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="230 KV" b3="B11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29880</SeqNum>
    <Name>RedOak.A&amp;B</Name>
    <LastEdit Timestamp="2024-06-12T14:46:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="REDOAKA" b2="230 KV" b3="2TRAN" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDOAKA" b2="230 KV" b3="3TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDOAKA" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDOAKA" b2="18 KV" b3="CT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDOAKA" b2="18 KV" b3="CT3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDOAKB" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDOAKB" b2="18 KV" b3="CT" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDOAKB" b2="230 KV" b3="CT TRAN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDOAKB" b2="18 KV" b3="ST" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDOAKB" b2="230 KV" b3="ST TRAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29890</SeqNum>
    <Name>RedOak.A Units</Name>
    <LastEdit Timestamp="2024-06-12T14:48:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="REDOAKA" b2="230 KV" b3="2TRAN" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDOAKA" b2="230 KV" b3="3TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDOAKA" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDOAKA" b2="18 KV" b3="CT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDOAKA" b2="18 KV" b3="CT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29900</SeqNum>
    <Name>RedOak.B Units</Name>
    <LastEdit Timestamp="2024-06-12T14:49:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDOAKB" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDOAKB" b2="18 KV" b3="CT" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDOAKB" b2="230 KV" b3="CT TRAN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDOAKB" b2="18 KV" b3="ST" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDOAKB" b2="230 KV" b3="ST TRAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29920</SeqNum>
    <Name>138/34.HickoryCreek.T4</Name>
    <LastEdit Timestamp="2025-04-14T10:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HICKORYC" b2="138 KV" b3="4-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="HICKORYC" b2="69 KV" b3="4-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="HICKORYC" b2="34 KV" b3="4-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORYC" b2="69 KV" b3="AP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORYC" b2="34 KV" b3="BG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORYC" b2="138 KV" b3="XT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29930</SeqNum>
    <Name>138/69.Illinois.T1</Name>
    <LastEdit Timestamp="2025-11-26T11:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ILLINOIS" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="X" Type="XF" b1="ILLINOIS" b2="138 KV" b3="XF1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ILLINOIS" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29940</SeqNum>
    <Name>345/138.AllenJunction.TR3</Name>
    <LastEdit Timestamp="2026-04-07T08:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="345 KV" b3="B34532" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="345 KV" b3="B42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="138 KV" b3="B43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="138 KV" b3="B44" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALLENJUN" b2="345 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>29990</SeqNum>
    <Name>L345.Beaver-Carlisle</Name>
    <LastEdit Timestamp="2026-01-06T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="121" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="124" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVER" b2="345 KV" b3="BEA-CAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="345 KV" b3="5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30000</SeqNum>
    <Name>L345.Beaver-DavisBesse</Name>
    <LastEdit Timestamp="2026-01-20T17:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="185" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVER" b2="345 KV" b3="BEA-DAV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B34564" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B65" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30010</SeqNum>
    <Name>L345.Bayshore-DavisBesse</Name>
    <LastEdit Timestamp="2026-01-16T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="345 KV" b3="44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="345 KV" b3="45" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAVISBES" b2="345 KV" b3="DAV-BAY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B34561" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B34562" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30020</SeqNum>
    <Name>L345.DavisBesse-Lemoyne</Name>
    <LastEdit Timestamp="2026-01-16T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B34563" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B34564" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAVISBES" b2="345 KV" b3="DAV-LEM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B34501" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B34502" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30040</SeqNum>
    <Name>L345.Hanna-Trumbull</Name>
    <LastEdit Timestamp="2024-11-27T10:47:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B191" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B194" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANNAOE" b2="345 KV" b3="HAN-TRUM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRUMBUL2" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRUMBUL2" b2="345 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30050</SeqNum>
    <Name>L345.Harding-Inland</Name>
    <LastEdit Timestamp="2025-04-01T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B30" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDING2" b2="345 KV" b3="HAR-INL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="345 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="345 KV" b3="B19" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30070</SeqNum>
    <Name>L345.Harding-Juniper</Name>
    <LastEdit Timestamp="2025-08-06T13:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B334" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIPER" b2="345 KV" b3="JUN-HAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B30" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30080</SeqNum>
    <Name>L345.Lemoyne-Majestic</Name>
    <LastEdit Timestamp="2026-04-07T09:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B34505" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B34506" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEMOYNE2" b2="345 KV" b3="MAJ-LEM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAJESTIC" b2="345 KV" b3="AF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAJESTIC" b2="345 KV" b3="AM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30090</SeqNum>
    <Name>L345.Lemoyne-Midway</Name>
    <LastEdit Timestamp="2026-04-07T09:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B34503" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B34504" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEMOYNE2" b2="345 KV" b3="LEM-MID1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="345 KV" b3="B34535" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="345 KV" b3="B34536" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30110</SeqNum>
    <Name>L345.East Lake-Perry</Name>
    <LastEdit Timestamp="2025-08-25T13:39:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="345 KV" b3="B734" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="345 KV" b3="B741" />
      <ContingencyEquipment Action="L" Type="LN" b1="PERRY_FE" b2="345 KV" b3="PER-EAS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30150</SeqNum>
    <Name>L345.NorthMedina-Star</Name>
    <LastEdit Timestamp="2026-04-07T09:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="N_MEDINA" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_MEDINA" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="N_MEDINA" b2="345 KV" b3="NME-STA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="108" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="109" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30170</SeqNum>
    <Name>Bayshore.BS10</Name>
    <LastEdit Timestamp="2024-06-12T14:39:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="138 KV" b3="1J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="138 KV" b3="1K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="18 KV" b3="BS-10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BAYSHOR2" b2="18 KV" b3="BS10" />
      <ContingencyEquipment Action="X" Type="XF" b1="BAYSHOR2" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30320</SeqNum>
    <Name>345/138.AllenJunction.TR1</Name>
    <LastEdit Timestamp="2026-04-07T08:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="138 KV" b3="B13370" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="138 KV" b3="B13371" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="345 KV" b3="B34530" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="345 KV" b3="B46" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALLENJUN" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30340</SeqNum>
    <Name>345/138.Bayshore.T1</Name>
    <LastEdit Timestamp="2026-01-02T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BAYSHOR2" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="345 KV" b3="40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="345 KV" b3="41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="138 KV" b3="B13260" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="138 KV" b3="B13261" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30350</SeqNum>
    <Name>345/138.Beaver.T1 </Name>
    <LastEdit Timestamp="2026-01-07T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="193" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="87" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="88" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAVER" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30360</SeqNum>
    <Name>345/138.Beaver.T2</Name>
    <LastEdit Timestamp="2026-01-07T10:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="124" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="185" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="196" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="219" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="9" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAVER" b2="345 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30370</SeqNum>
    <Name>345/138.Carlisle.TR1</Name>
    <LastEdit Timestamp="2024-06-12T14:41:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="219" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="345 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="64" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="345 KV" b3="8" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARLISLE" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30380</SeqNum>
    <Name>345/138.Chamberlin.T3</Name>
    <LastEdit Timestamp="2026-04-07T08:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B178" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B181" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="345 KV" b3="B87" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="345 KV" b3="B88" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHAMBROE" b2="345 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30410</SeqNum>
    <Name>345/138.Fox.T2&amp;T3</Name>
    <LastEdit Timestamp="2025-06-26T11:51:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FOX" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="X" Type="XF" b1="FOX" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="345 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="345 KV" b3="B25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30420</SeqNum>
    <Name>345/138.Fox.T4&amp;T5</Name>
    <LastEdit Timestamp="2025-06-26T11:51:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FOX" b2="345 KV" b3="4" />
      <ContingencyEquipment Action="X" Type="XF" b1="FOX" b2="345 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="345 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="345 KV" b3="B27" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30430</SeqNum>
    <Name>345/138.Galion.T3</Name>
    <LastEdit Timestamp="2026-04-07T08:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="345 KV" b3="159" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="345 KV" b3="162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="CS136" />
      <ContingencyEquipment Action="X" Type="XF" b1="GALION" b2="345 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30440</SeqNum>
    <Name>345/138.Galion.T4</Name>
    <LastEdit Timestamp="2026-04-07T08:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="345 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="345 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="CS137" />
      <ContingencyEquipment Action="X" Type="XF" b1="GALION" b2="345 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30450</SeqNum>
    <Name>345/138.Hanna.TX1</Name>
    <LastEdit Timestamp="2025-08-22T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HANNAOE" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B108" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30460</SeqNum>
    <Name>345/138.Hanna.TX2</Name>
    <LastEdit Timestamp="2025-08-22T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HANNAOE" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B109" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B179" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B191" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="GENCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HANNAOE" b2="345 KV" b3="GENDUMMY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30470</SeqNum>
    <Name>345/138.Harding.T1&amp;T2</Name>
    <LastEdit Timestamp="2025-03-14T10:54:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HARDING2" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARDING2" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B27" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30490</SeqNum>
    <Name>345/138.Hoytdale.T1</Name>
    <LastEdit Timestamp="2025-03-26T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HOYTDAL2" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="345 KV" b3="106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="345 KV" b3="110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="67" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30500</SeqNum>
    <Name>345/138.Hoytdale.T2</Name>
    <LastEdit Timestamp="2025-03-26T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="345 KV" b3="102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="345 KV" b3="114" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOYTDAL2" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="26" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30510</SeqNum>
    <Name>345/138.Inland.3</Name>
    <LastEdit Timestamp="2025-03-31T16:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="INLAND" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="345 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="345 KV" b3="B17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30520</SeqNum>
    <Name>345/138.Inland.4</Name>
    <LastEdit Timestamp="2025-03-31T16:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="INLAND" b2="345 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="345 KV" b3="B18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="345 KV" b3="B19" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30530</SeqNum>
    <Name>345/138.Juniper.T2&amp;T3</Name>
    <LastEdit Timestamp="2025-11-12T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="JUNIPER" b2="345 KV" b3="2 XFMR" />
      <ContingencyEquipment Action="X" Type="XF" b1="JUNIPER" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B32" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30540</SeqNum>
    <Name>345/138.Juniper.T5</Name>
    <LastEdit Timestamp="2025-11-12T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B35" />
      <ContingencyEquipment Action="X" Type="XF" b1="JUNIPER" b2="345 KV" b3="BK5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30550</SeqNum>
    <Name>345/138.Juniper.T6</Name>
    <LastEdit Timestamp="2025-11-12T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="456" />
      <ContingencyEquipment Action="X" Type="XF" b1="JUNIPER" b2="345 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30560</SeqNum>
    <Name>345/138.Lemoyne.TR1</Name>
    <LastEdit Timestamp="2024-06-12T14:43:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LEMOYNE2" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="138 KV" b3="13360" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="138 KV" b3="13361" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B34501" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B34505" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30570</SeqNum>
    <Name>345/138.Lemoyne.TR2</Name>
    <LastEdit Timestamp="2024-06-12T14:44:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="138 KV" b3="13362" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="138 KV" b3="13363" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEMOYNE2" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B34502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B34503" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30590</SeqNum>
    <Name>345/138.Shenango.T1</Name>
    <LastEdit Timestamp="2025-07-28T10:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SHENANGO" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="345 KV" b3="106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="345 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="D4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30600</SeqNum>
    <Name>345/138.Shenango.T2</Name>
    <LastEdit Timestamp="2025-07-28T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="345 KV" b3="110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="345 KV" b3="134" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHENANGO" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="D66" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30610</SeqNum>
    <Name>345/138.Star(FE).T2</Name>
    <LastEdit Timestamp="2026-04-07T08:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="13" />
      <ContingencyEquipment Action="X" Type="XF" b1="STAR_FE" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="5_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30630</SeqNum>
    <Name>L345.WestMilton-MiamiFort</Name>
    <LastEdit Timestamp="2025-07-10T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1405" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1407" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIAMIFOR" b2="345 KV" b3="MIA-WMI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="345 KV" b3="OC-DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="345 KV" b3="OC-EE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30650</SeqNum>
    <Name>L345.Bath-Foster</Name>
    <LastEdit Timestamp="2025-07-11T13:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTER2" b2="345 KV" b3="FOS-BAT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="345 KV" b3="GL-EE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="345 KV" b3="GL-GG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="345 KV" b3="1349" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="345 KV" b3="1351" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30670</SeqNum>
    <Name>L138.WestMilton-Greenville</Name>
    <LastEdit Timestamp="2025-11-07T15:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09GRNVIL" b2="69 KV" b3="21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09GRNVIL" b2="69 KV" b3="22" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09GRNVIL" b2="69 KV" b3="BK-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="WMILTON" b2="138 KV" b3="WMI-09G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="138 KV" b3="OC-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="138 KV" b3="OC-J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30690</SeqNum>
    <Name>L138.Sugarcreek-Centerville</Name>
    <LastEdit Timestamp="2025-10-17T12:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09CENTER" b2="138 KV" b3="AF-A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09CENTER" b2="138 KV" b3="BK-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="09CENTER" b2="138 KV" b3="CEN-SUGA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="138 KV" b3="RS-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="138 KV" b3="RS-H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30700</SeqNum>
    <Name>L138.Sugarcreek-09Bellbrook</Name>
    <LastEdit Timestamp="2025-03-28T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09BELLBR" b2="138 KV" b3="A CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09BELLBR" b2="138 KV" b3="BK-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUGARCRE" b2="138 KV" b3="SUG-09B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="138 KV" b3="RS-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="138 KV" b3="RS-J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30710</SeqNum>
    <Name>L138.Shelby-Sidney</Name>
    <LastEdit Timestamp="2024-09-16T16:59:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09SIDNEY" b2="138 KV" b3="BA-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09SIDNEY" b2="138 KV" b3="BA-B" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHELBY" b2="138 KV" b3="SHE-09S1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30720</SeqNum>
    <Name>L138.Shelby-EastSidney-Kiser</Name>
    <LastEdit Timestamp="2024-10-23T09:39:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09ESIDNY" b2="138 KV" b3="BK-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="09ESIDNY" b2="138 KV" b3="ESI-KISE" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHELBY" b2="138 KV" b3="SHE-09E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KISER" b2="138 KV" b3="EB-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KISER" b2="138 KV" b3="EB-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30740</SeqNum>
    <Name>L138.Miami-Staunton-Eldean + 138/69.Staunton.T7</Name>
    <LastEdit Timestamp="2026-01-16T13:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="09STAUNT" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09STAUNT" b2="69 KV" b3="BL-7N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09STAUNT" b2="69 KV" b3="BL-7S" />
      <ContingencyEquipment Action="L" Type="LN" b1="13836TAP" b2="138 KV" b3="09S-09S2" />
      <ContingencyEquipment Action="L" Type="LN" b1="13836TAP" b2="138 KV" b3="138-ELD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIAMI" b2="138 KV" b3="MIA-09S1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDEAN1" b2="138 KV" b3="OR-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDEAN1" b2="138 KV" b3="OR-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="138 KV" b3="N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30750</SeqNum>
    <Name>L138.Miami-Northridge</Name>
    <LastEdit Timestamp="2026-04-07T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09NORTHR" b2="138 KV" b3="BK-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09NORTHR" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIAMI" b2="138 KV" b3="MIA-09N2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="138 KV" b3="P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30760</SeqNum>
    <Name>L138.Miami-Haas-Carlisle</Name>
    <LastEdit Timestamp="2025-01-31T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09NCARLI" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAAS" b2="138 KV" b3="HAA-NCAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAAS" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAAS" b2="138 KV" b3="HAA-MIAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="138 KV" b3="P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30780</SeqNum>
    <Name>L138.Hutching-Crown + 138/69.Crown.T7</Name>
    <LastEdit Timestamp="2026-04-07T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CROWN" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROWN" b2="69 KV" b3="BL-7" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUTCHING" b2="138 KV" b3="HUT-09C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="138 KV" b3="AA-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="138 KV" b3="AA-B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30790</SeqNum>
    <Name>L138.Hillsboro-MiddleSwitch-Middleboro-Hutching</Name>
    <LastEdit Timestamp="2025-04-14T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSBOR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSBOR" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSBOR" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLSBOR" b2="138 KV" b3="HIL-MIDS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="138 KV" b3="AA-E" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUTCHING" b2="138 KV" b3="HUT-MID" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDD DAY" b2="138 KV" b3="BK-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDDLESW" b2="138 KV" b3="MID-MIDD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30810</SeqNum>
    <Name>L138.Greene-Trebein</Name>
    <LastEdit Timestamp="2025-07-23T16:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09TREBEI" b2="138 KV" b3="GB-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09TREBEI" b2="138 KV" b3="GB-C" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENE" b2="138 KV" b3="GRE-09T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30830</SeqNum>
    <Name>L138.Greene-Knollwood</Name>
    <LastEdit Timestamp="2026-04-07T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09KNOLLW" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09KNOLLW" b2="138 KV" b3="BK-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENE" b2="138 KV" b3="GRE-09K1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30840</SeqNum>
    <Name>L138.Greene-09Alpha</Name>
    <LastEdit Timestamp="2026-04-07T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09ALPHA" b2="138 KV" b3="A_" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENE" b2="138 KV" b3="GRE-09A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30850</SeqNum>
    <Name>L138.Greene-09Airway + 09Airway.T7</Name>
    <LastEdit Timestamp="2026-04-07T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="09AIRWAY" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09AIRWAY" b2="69 KV" b3="BK-7N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09AIRWAY" b2="69 KV" b3="BK-7S" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENE" b2="138 KV" b3="GRE-09A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30860</SeqNum>
    <Name>L138.Delaware-WatkinsRoadTap-Darby</Name>
    <LastEdit Timestamp="2025-05-12T14:29:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARBY" b2="138 KV" b3="CG-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARBY" b2="138 KV" b3="CG-F" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARBY" b2="138 KV" b3="DAR-WAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELAWARE" b2="138 KV" b3="104" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELAWARE" b2="138 KV" b3="DEL-WAT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WATK TAP" b2="138 KV" b3="WATK UN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WATK TAP" b2="138 KV" b3="WATK UN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30870</SeqNum>
    <Name>L138.Darby-EagleRoad-Mechanicsburg-Givens-Urbana</Name>
    <LastEdit Timestamp="2025-05-12T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="09GIVENS" b2="138 KV" b3="09G-09M1" />
      <ContingencyEquipment Action="L" Type="LN" b1="09URBANA" b2="138 KV" b3="09U-09G1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09GIVENS" b2="138 KV" b3="BK-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="09MECHAN" b2="138 KV" b3="09M-EAG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09MECHAN" b2="138 KV" b3="BK-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09URBANA" b2="138 KV" b3="A_" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09URBANA" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARBY" b2="138 KV" b3="CG-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARBY" b2="138 KV" b3="CG-F" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARBY" b2="138 KV" b3="DAR-EAG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EAGLEREA" b2="138 KV" b3="EAGLEREA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30880</SeqNum>
    <Name>L138.Bath-Trebein</Name>
    <LastEdit Timestamp="2025-05-12T14:27:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BATH" b2="138 KV" b3="BAT-09T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09TREBEI" b2="138 KV" b3="GB-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09TREBEI" b2="138 KV" b3="GB-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="138 KV" b3="GL-G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="138 KV" b3="GL-H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30890</SeqNum>
    <Name>L138.Bath-Carlisle</Name>
    <LastEdit Timestamp="2025-05-12T14:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BATH" b2="138 KV" b3="BAT-09N1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09NCARLI" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="138 KV" b3="GL-H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="138 KV" b3="GL-I" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30900</SeqNum>
    <Name>L138.Urbana-Broadview</Name>
    <LastEdit Timestamp="2024-11-04T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09URBANA" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09URBANA" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADVW" b2="138 KV" b3="B68" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADVW" b2="138 KV" b3="B69" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROADVW" b2="138 KV" b3="BRO-URB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30910</SeqNum>
    <Name>L138.Urbana-Bath</Name>
    <LastEdit Timestamp="2025-05-12T14:21:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="09URBANA" b2="138 KV" b3="09U-BAT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09URBANA" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09URBANA" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="138 KV" b3="GL-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="138 KV" b3="GL-F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30920</SeqNum>
    <Name>L138.Sidney-MillCreek </Name>
    <LastEdit Timestamp="2024-09-16T16:59:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="09SIDNEY" b2="138 KV" b3="09S1-MIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09SIDNEY" b2="138 KV" b3="BA-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09SIDNEY" b2="138 KV" b3="BA-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILCREEK" b2="138 KV" b3="BU-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILCREEK" b2="138 KV" b3="BU-F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30930</SeqNum>
    <Name>L138.Monument-Wyandot</Name>
    <LastEdit Timestamp="2026-04-07T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="09MONUMT" b2="138 KV" b3="09M-09W4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09MONUMT" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09MONUMT" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09WYANA" b2="138 KV" b3="BK-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30940</SeqNum>
    <Name>L138.Monument-Webster.1 + 138/12.Monumt.T-C</Name>
    <LastEdit Timestamp="2026-04-07T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="09MONUMT" b2="138 KV" b3="09M-09W1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09MONUMT" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="X" Type="XF" b1="09MONUMT" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09MONUMT" b2="12 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09WEBSTR" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09WEBSTR" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30950</SeqNum>
    <Name>L138.Monument-Webster.2</Name>
    <LastEdit Timestamp="2026-04-07T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="09MONUMT" b2="138 KV" b3="09M-09W3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09MONUMT" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09WEBSTR" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09WEBSTR" b2="138 KV" b3="K" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30960</SeqNum>
    <Name>L138.Monument-Wyanb</Name>
    <LastEdit Timestamp="2026-04-07T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="09MONUMT" b2="138 KV" b3="09M-09W2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09MONUMT" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09MONUMT" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09WYANB" b2="138 KV" b3="BK-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30970</SeqNum>
    <Name>L138.Monument-Overlook-Knollwood + Overlook.BK-7</Name>
    <LastEdit Timestamp="2026-04-07T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="09KNOLLW" b2="138 KV" b3="09K-09O2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09KNOLLW" b2="138 KV" b3="A CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09KNOLLW" b2="138 KV" b3="BK-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="09MONUMT" b2="138 KV" b3="09M-09O1" />
      <ContingencyEquipment Action="X" Type="XF" b1="09MONUMT" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09MONUMT" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09MONUMT" b2="12 KV" b3="K" />
      <ContingencyEquipment Action="X" Type="XF" b1="09OVERLK" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09OVERLK" b2="69 KV" b3="BL-7E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09OVERLK" b2="69 KV" b3="BL-7W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30980</SeqNum>
    <Name>L138.Monument-Overlook-Greene</Name>
    <LastEdit Timestamp="2026-04-07T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="09MONUMT" b2="138 KV" b3="09M-09O2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09MONUMT" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09OVERLK" b2="138 KV" b3="BK-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENE" b2="138 KV" b3="GRE-09O1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>30990</SeqNum>
    <Name>L138.Kiser-Quincy-Logan + 138/69.T7</Name>
    <LastEdit Timestamp="2025-02-18T12:56:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="09LOGAN" b2="138 KV" b3="09L-09Q1" />
      <ContingencyEquipment Action="X" Type="XF" b1="09LOGAN" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09LOGAN" b2="69 KV" b3="BL7" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09QUINCY" b2="138 KV" b3="BK-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KISER" b2="138 KV" b3="EB-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KISER" b2="138 KV" b3="EB-F" />
      <ContingencyEquipment Action="L" Type="LN" b1="KISER" b2="138 KV" b3="KIS-QUIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31010</SeqNum>
    <Name>L138.Northridge-Cargil-Needmore</Name>
    <LastEdit Timestamp="2026-04-07T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="09CARGIL" b2="138 KV" b3="09C-09N1" />
      <ContingencyEquipment Action="L" Type="LN" b1="09CARGIL" b2="138 KV" b3="09C-09N2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09CARGIL" b2="138 KV" b3="BK-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09NEEDMO" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09NORTHR" b2="138 KV" b3="BK-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09NORTHR" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31020</SeqNum>
    <Name>L138.Centerville-Hempstead + Hempstead.T7</Name>
    <LastEdit Timestamp="2025-03-14T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="09CENTER" b2="138 KV" b3="09C-09H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09CENTER" b2="138 KV" b3="AF-A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09CENTER" b2="138 KV" b3="BK-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09HEMPST" b2="69 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09HEMPST" b2="69 KV" b3="6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09HEMPST" b2="69 KV" b3="BK-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="09HEMPST" b2="138 KV" b3="BK-7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31040</SeqNum>
    <Name>L138.Needmore-AGAGas-Webster</Name>
    <LastEdit Timestamp="2026-04-07T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09NEEDMO" b2="138 KV" b3="A_1CA869" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09NEEDMO" b2="138 KV" b3="BK-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09WEBSTR" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09WEBSTR" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="AGA GAS" b2="138 KV" b3="AGA-09N2" />
      <ContingencyEquipment Action="L" Type="LN" b1="AGA GAS" b2="138 KV" b3="AGA-09W1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AGA GAS" b2="138 KV" b3="BK-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31050</SeqNum>
    <Name>L138.09Alpha-09Bellbr</Name>
    <LastEdit Timestamp="2026-04-07T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="09ALPHA" b2="138 KV" b3="09A-09B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09ALPHA" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09BELLBR" b2="138 KV" b3="A CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09BELLBR" b2="138 KV" b3="BK-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31060</SeqNum>
    <Name>L138.Stuart-Brown</Name>
    <LastEdit Timestamp="2026-05-08T16:08:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08BROWN" b2="138 KV" b3="832" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08BROWN" b2="138 KV" b3="834" />
      <ContingencyEquipment Action="L" Type="LN" b1="08BROWN" b2="138 KV" b3="08B-08ST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08STUART" b2="138 KV" b3="944" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08STUART" b2="138 KV" b3="948" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31100</SeqNum>
    <Name>138/69.Sidney.BK-7</Name>
    <LastEdit Timestamp="2025-11-25T16:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09SIDNEY" b2="138 KV" b3="BA-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09SIDNEY" b2="138 KV" b3="BA-D" />
      <ContingencyEquipment Action="X" Type="XF" b1="09SIDNEY" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09SIDNEY" b2="69 KV" b3="BL-7N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09SIDNEY" b2="69 KV" b3="BL-7S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31110</SeqNum>
    <Name>138/69.Trebein.BK-7</Name>
    <LastEdit Timestamp="2025-07-22T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="09TREBEI" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09TREBEI" b2="69 KV" b3="BL-7N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09TREBEI" b2="69 KV" b3="BL-7S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09TREBEI" b2="138 KV" b3="GB-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09TREBEI" b2="138 KV" b3="GB-B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31130</SeqNum>
    <Name>138/69.Webster.T7</Name>
    <LastEdit Timestamp="2026-04-07T08:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="09WEBSTR" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09WEBSTR" b2="69 KV" b3="BL-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09WEBSTR" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09WEBSTR" b2="138 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31140</SeqNum>
    <Name>138/69.Bath.BK-7</Name>
    <LastEdit Timestamp="2025-08-04T12:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="138 KV" b3="BH-7CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BATH" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="69 KV" b3="GL-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31160</SeqNum>
    <Name>138/69.Hutching.T7A</Name>
    <LastEdit Timestamp="2025-04-15T13:56:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HUTCHING" b2="138 KV" b3="7A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="138 KV" b3="AA-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="138 KV" b3="AA-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="138 KV" b3="AA-H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="69 KV" b3="BL-7N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="69 KV" b3="BL-7S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31170</SeqNum>
    <Name>138/69.Hutching.T8</Name>
    <LastEdit Timestamp="2025-04-15T13:54:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="HUTCHING" b2="138 KV" b3="138R" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUTCHING" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="138 KV" b3="AA-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="138 KV" b3="AA-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="138 KV" b3="AA-G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="138 KV" b3="AA-J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="69 KV" b3="BL-8N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="69 KV" b3="BL-8S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31180</SeqNum>
    <Name>138/69.Miami.BK-7</Name>
    <LastEdit Timestamp="2026-04-07T08:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="69 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="69 KV" b3="4" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIAMI" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="138 KV" b3="K" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31190</SeqNum>
    <Name>345/138.Stuart.T7</Name>
    <LastEdit Timestamp="2026-05-08T16:16:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08STUART" b2="345 KV" b3="1547" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08STUART" b2="138 KV" b3="941" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08STUART" b2="138 KV" b3="944" />
      <ContingencyEquipment Action="X" Type="XF" b1="08STUART" b2="345 KV" b3="BK7-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="08STUART" b2="138 KV" b3="BK7-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31200</SeqNum>
    <Name>138/69.Stuart.BK-16</Name>
    <LastEdit Timestamp="2026-05-11T08:51:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08STUART" b2="69 KV" b3="716" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08STUART" b2="138 KV" b3="941" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08STUART" b2="138 KV" b3="948" />
      <ContingencyEquipment Action="X" Type="XF" b1="08STUART" b2="138 KV" b3="BK-16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31210</SeqNum>
    <Name>138/69.WestMilton.T7</Name>
    <LastEdit Timestamp="2025-05-12T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WMILTON" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="69 KV" b3="OC-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="69 KV" b3="OC-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="138 KV" b3="OC-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="138 KV" b3="OC-F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31230</SeqNum>
    <Name>L138.FremontCenter-Fremont-WestFremont</Name>
    <LastEdit Timestamp="2025-12-16T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FREMNT" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="FREMNT" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="FREMNT" b2="12 KV" b3="1-T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FREMNT" b2="12 KV" b3="12KV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMNT" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMNT" b2="69 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMNT" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMNT" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="FREMNT" b2="138 KV" b3="FRE-FRE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FREMNT" b2="69 KV" b3="LD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMNT" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONTC" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="L" Type="LN" b1="FREMNT" b2="138 KV" b3="FRE-WFR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31250</SeqNum>
    <Name>L138.EastLeipsic-Newberry</Name>
    <LastEdit Timestamp="2024-12-05T16:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELEIPSIC" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELEIPSIC" b2="138 KV" b3="ELE-NEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWBERY" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31260</SeqNum>
    <Name>L138.WestCanton-DaleOE</Name>
    <LastEdit Timestamp="2026-04-07T13:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DALEOE" b2="138 KV" b3="B36" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="WCANTON" b2="138 KV" b3="WCA-DAL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31270</SeqNum>
    <Name>L138.CantonCentral-Bluebell</Name>
    <LastEdit Timestamp="2026-04-07T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BLUEBELL" b2="138 KV" b3="A118" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEBELL" b2="138 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANTONCE" b2="138 KV" b3="CAN-BLU1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31290</SeqNum>
    <Name>L138.CantonCentral-Cloverdale</Name>
    <LastEdit Timestamp="2025-11-17T15:58:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANTONCE" b2="138 KV" b3="CAN-CLO1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLOVEROE" b2="138 KV" b3="A48" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="138 KV" b3="B100" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31310</SeqNum>
    <Name>L138.EastWooster-Cloverdale</Name>
    <LastEdit Timestamp="2025-11-17T15:59:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLOVEROE" b2="138 KV" b3="A44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="138 KV" b3="B107" />
      <ContingencyEquipment Action="L" Type="LN" b1="EWOOSTER" b2="138 KV" b3="EWO-CLO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWOOSTER" b2="138 KV" b3="R" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31350</SeqNum>
    <Name>L230.PossumPt-Woodbridge-Occoquan.2001</Name>
    <LastEdit Timestamp="2024-05-14T09:55:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OCCOQUAN" b2="230 KV" b3="20012013" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCCOQUAN" b2="230 KV" b3="20012042" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OCCOQUAN" b2="35 KV" b3="I95LF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OCCOQUAN" b2="35 KV" b3="I95LF2" />
      <ContingencyEquipment Action="X" Type="XF" b1="OCCOQUAN" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OCCOQUAN" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="200192" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="G4T2001" />
      <ContingencyEquipment Action="L" Type="LN" b1="WOODBRGE" b2="230 KV" b3="2001A" />
      <ContingencyEquipment Action="L" Type="LN" b1="WOODBRGE" b2="230 KV" b3="2001B" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODBRGE" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODBRGE" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31380</SeqNum>
    <Name>L230.Peninsula-Shellbank.2004</Name>
    <LastEdit Timestamp="2025-02-26T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENINSLA" b2="230 KV" b3="288T2004" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELLBNK" b2="230 KV" b3="200452" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHELLBNK" b2="230 KV" b3="2004A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHELLBNK" b2="22 KV" b3="TX5LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHELLBNK" b2="230 KV" b3="TX_5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31390</SeqNum>
    <Name>L230.Clark-Hunter.2005</Name>
    <LastEdit Timestamp="2026-04-07T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARK4" b2="230 KV" b3="2005T203" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARK4" b2="230 KV" b3="202T2005" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLARK4" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLARK4" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTER" b2="230 KV" b3="2005A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTER" b2="230 KV" b3="264T2005" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUNTER" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUNTER" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31410</SeqNum>
    <Name>L230.Lynnhaven-Thalia.2007</Name>
    <LastEdit Timestamp="2025-06-06T11:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNNHAVN" b2="230 KV" b3="20072025" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNNHAVN" b2="230 KV" b3="200782" />
      <ContingencyEquipment Action="L" Type="LN" b1="LYNNHAVN" b2="230 KV" b3="2007A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THALIA" b2="230 KV" b3="20072019" />
      <ContingencyEquipment Action="X" Type="XF" b1="THALIA" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THALIA" b2="35 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31420</SeqNum>
    <Name>L230.ShortPump-Rockvlle-NPole-Midlothian.2009</Name>
    <LastEdit Timestamp="2026-04-09T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLOTH" b2="230 KV" b3="200912" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLOTH" b2="230 KV" b3="20092066" />
      <ContingencyEquipment Action="L" Type="LN" b1="NPOLE" b2="230 KV" b3="2009A" />
      <ContingencyEquipment Action="L" Type="LN" b1="NPOLE" b2="230 KV" b3="2009B1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NPOLE" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NPOLE" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NPOLE" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NPOLE" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKVILE" b2="230 KV" b3="2009C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKVILE" b2="230 KV" b3="H152" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKVILE" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKVILE" b2="36.5 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKVILE" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKVILE" b2="36.5 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHORTPMP" b2="230 KV" b3="20092103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHORTPMP" b2="230 KV" b3="H242" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31430</SeqNum>
    <Name>L230.Reston-Tysons.2010</Name>
    <LastEdit Timestamp="2024-08-22T10:44:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RESTON" b2="230 KV" b3="20102062" />
      <ContingencyEquipment Action="L" Type="LN" b1="RESTON" b2="230 KV" b3="2010A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RESTON" b2="230 KV" b3="264T2010" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYSONS" b2="230 KV" b3="20102108" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYSONS" b2="230 KV" b3="201032" />
      <ContingencyEquipment Action="S" Type="SD" b1="TYSONS" b2="230 KV" b3="2010_UG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31450</SeqNum>
    <Name>L230.Occoquan-Ox.2013</Name>
    <LastEdit Timestamp="2024-05-14T09:56:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OCCOQUAN" b2="230 KV" b3="20012013" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCCOQUAN" b2="230 KV" b3="20132042" />
      <ContingencyEquipment Action="L" Type="LN" b1="OCCOQUAN" b2="230 KV" b3="2013A" />
      <ContingencyEquipment Action="X" Type="XF" b1="OCCOQUAN" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OCCOQUAN" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="201342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="248T2013" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31460</SeqNum>
    <Name>L230.Earleys-HoggardMill-Everetts.2014</Name>
    <LastEdit Timestamp="2025-08-29T13:09:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="20122014" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="201462" />
      <ContingencyEquipment Action="L" Type="LN" b1="EARLEYS" b2="230 KV" b3="EAR-HOGA" />
      <ContingencyEquipment Action="L" Type="LN" b1="EVERETTS" b2="230 KV" b3="EVE-HOGA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERETTS" b2="230 KV" b3="H2T2014" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERETTS" b2="230 KV" b3="H312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERETTS" b2="230 KV" b3="H4T2014" />
      <ContingencyEquipment Action="X" Type="XF" b1="EVERETTS" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EVERETTS" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOGARDML" b2="230 KV" b3="H122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOGARDML" b2="230 KV" b3="H222" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31470</SeqNum>
    <Name>L230.Dulles-Reston.2015</Name>
    <LastEdit Timestamp="2024-08-19T12:26:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DULLES" b2="230 KV" b3="201582-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DULLES" b2="230 KV" b3="201582-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RESTON" b2="230 KV" b3="20152043" />
      <ContingencyEquipment Action="L" Type="LN" b1="RESTON" b2="230 KV" b3="2015A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RESTON" b2="230 KV" b3="264T2015" />
      <ContingencyEquipment Action="X" Type="XF" b1="RESTON" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RESTON" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31480</SeqNum>
    <Name>L230.Lanexa-Corrct-PaprMill-HarmonyVillage.2016</Name>
    <LastEdit Timestamp="2026-04-09T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORECTNL" b2="230 KV" b3="2016A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORECTNL" b2="230 KV" b3="2016B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CORECTNL" b2="35 KV" b3="CORECTSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="CORECTNL" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CORECTNL" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAPERMIL" b2="230 KV" b3="2016C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONYV" b2="230 KV" b3="H262" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HARMONYV" b2="35 KV" b3="PULLERSP" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HARMONYV" b2="230 KV" b3="SC6" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARMONYV" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARMONYV" b2="35 KV" b3="TX4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="230 KV" b3="20162024" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="230 KV" b3="201632" />
      <ContingencyEquipment Action="X" Type="XF" b1="PAPERMIL" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PAPERMIL" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31490</SeqNum>
    <Name>L230.EndlessCaverns-EastMarketSt-Harrisonburg.2017</Name>
    <LastEdit Timestamp="2026-04-07T13:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ENDCAVRN" b2="230 KV" b3="2017B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="230 KV" b3="H4T2017" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="230 KV" b3="H5T2017" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="230 KV" b3="201792" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="230 KV" b3="253T2017" />
      <ContingencyEquipment Action="L" Type="LN" b1="HRSNBGDP" b2="230 KV" b3="2017A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HRSNBGDP" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31500</SeqNum>
    <Name>L230.Greenwich-ElizabethRiver.2018</Name>
    <LastEdit Timestamp="2025-08-26T17:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZRIV" b2="230 KV" b3="20182070" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZRIV" b2="230 KV" b3="20182071" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="230 KV" b3="201852" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENWCH" b2="230 KV" b3="2018A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="230 KV" b3="H1T2018" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31510</SeqNum>
    <Name>L230.Greenwich-Thalia.2019</Name>
    <LastEdit Timestamp="2025-06-06T11:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="230 KV" b3="201952" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="230 KV" b3="245T2019" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THALIA" b2="230 KV" b3="20072019" />
      <ContingencyEquipment Action="L" Type="LN" b1="THALIA" b2="230 KV" b3="2019A" />
      <ContingencyEquipment Action="X" Type="XF" b1="THALIA" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THALIA" b2="35 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31520</SeqNum>
    <Name>L230.ElizCity-ChurchSt-TangW-Pasqtank-Winfall.2020</Name>
    <LastEdit Timestamp="2026-05-11T07:54:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHURCHST" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCHST" b2="230 KV" b3="2020C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZBETH" b2="230 KV" b3="2020T202" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELIZBETH" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELIZBETH" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WINFALL" b2="230 KV" b3="2020A1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PASQTANK" b2="35 KV" b3="ELIZCYSP" />
      <ContingencyEquipment Action="L" Type="LN" b1="PASQTANK" b2="230 KV" b3="PAS-TANG" />
      <ContingencyEquipment Action="X" Type="XF" b1="PASQTANK" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PASQTANK" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCHST" b2="230 KV" b3="2020B1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TANGLEDP" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINFALL" b2="230 KV" b3="20202144" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINFALL" b2="230 KV" b3="202022" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31530</SeqNum>
    <Name>L230.ElizabethCity-Shawboro.2021</Name>
    <LastEdit Timestamp="2026-04-08T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZBETH" b2="230 KV" b3="2020T202" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIZBETH" b2="230 KV" b3="2021A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ELIZBETH" b2="35 KV" b3="IVYNECSP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ELIZBETH" b2="35 KV" b3="MORCNRSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELIZBETH" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELIZBETH" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWBORO" b2="230 KV" b3="20212073" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWBORO" b2="230 KV" b3="20212136" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SHAWBORO" b2="230 KV" b3="SC2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31540</SeqNum>
    <Name>L230.PossumPt-Dumfries-Lakeridge-Ravensworth.2022</Name>
    <LastEdit Timestamp="2025-06-06T11:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DUMFRIES" b2="230 KV" b3="2022A" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUMFRIES" b2="230 KV" b3="2022B" />
      <ContingencyEquipment Action="X" Type="XF" b1="DUMFRIES" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUMFRIES" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DUMFRIES" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUMFRIES" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKRIDGE" b2="230 KV" b3="2022C" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKRIDGE" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAKRIDGE" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="202292" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="252T2022" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAVNSWTH" b2="230 KV" b3="270T2022" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAVNSWTH" b2="230 KV" b3="281T2022" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31560</SeqNum>
    <Name>L230.Lanexa-Chickahominy.2024</Name>
    <LastEdit Timestamp="2026-02-26T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="20242091" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="202422" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICKHOM" b2="230 KV" b3="2024A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="230 KV" b3="20162024" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="230 KV" b3="202432" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31570</SeqNum>
    <Name>L230.Greenrun-Lynnhaven.2025</Name>
    <LastEdit Timestamp="2025-06-16T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GREENRUN" b2="230 KV" b3="2025A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENRUN" b2="230 KV" b3="245T2025" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENRUN" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENRUN" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNNHAVN" b2="230 KV" b3="20072025" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNNHAVN" b2="230 KV" b3="202582" />
      <ContingencyEquipment Action="X" Type="XF" b1="LYNNHAVN" b2="230 KV" b3="TX5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LYNNHAVN" b2="35 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31580</SeqNum>
    <Name>L230.Landstown-Lynnhaven.2026</Name>
    <LastEdit Timestamp="2026-04-09T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="230 KV" b3="202652" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="230 KV" b3="231T2026" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNNHAVN" b2="230 KV" b3="20262072" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNNHAVN" b2="230 KV" b3="202682" />
      <ContingencyEquipment Action="L" Type="LN" b1="LYNNHAVN" b2="230 KV" b3="2026A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31590</SeqNum>
    <Name>L230.Bremo-Cartersville-Powhatan-Midlothian.2027</Name>
    <LastEdit Timestamp="2026-03-02T11:41:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="230 KV" b3="202722" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARTERSV" b2="230 KV" b3="2027A3" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARTERSV" b2="230 KV" b3="2027A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTERSV" b2="230 KV" b3="H192" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARTERSV" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARTERSV" b2="230 KV" b3="TX1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLOTH" b2="230 KV" b3="202712" />
      <ContingencyEquipment Action="S" Type="SD" b1="MIDLOTH" b2="230 KV" b3="2027Z" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLOTH" b2="230 KV" b3="242T2027" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLOTH" b2="230 KV" b3="H112" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDLOTH" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDLOTH" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="POWHATAN" b2="230 KV" b3="2027B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="POWHATAN" b2="35 KV" b3="POWHA2SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="POWHATAN" b2="35 KV" b3="POWHATSP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="POWHATAN" b2="35 KV" b3="QUILLWSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="POWHATAN" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POWHATAN" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="POWHATAN" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POWHATAN" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POWHATAN" b2="230 KV" b3="TX3 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31600</SeqNum>
    <Name>L230.Charltsv-MtEagle-Grapevine-ForkUnion.2028</Name>
    <LastEdit Timestamp="2025-12-16T12:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLTSV" b2="230 KV" b3="20282054" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLTSV" b2="230 KV" b3="233T2028" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRKUNION" b2="230 KV" b3="20282193" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRKUNION" b2="230 KV" b3="202872" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRAPEVIN" b2="115 KV" b3="CUNNINLD" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRKUNION" b2="230 KV" b3="FRK-GRAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAPEVIN" b2="230 KV" b3="H152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAPEVIN" b2="230 KV" b3="H252" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTEAGLE" b2="230 KV" b3="2028A" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAPEVIN" b2="230 KV" b3="GRA-MTEA" />
      <ContingencyEquipment Action="X" Type="XF" b1="MTEAGLE" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTEAGLE" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31610</SeqNum>
    <Name>L230.CIA-SwinksMill.2029</Name>
    <LastEdit Timestamp="2024-11-15T11:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CIA" b2="230 KV" b3="20292035" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CIA" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CIA" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CIA" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CIA" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWINKMIL" b2="230 KV" b3="20292108" />
      <ContingencyEquipment Action="L" Type="LN" b1="SWINKMIL" b2="230 KV" b3="2029B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWINKMIL" b2="230 KV" b3="H242" />
      <ContingencyEquipment Action="X" Type="XF" b1="SWINKMIL" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWINKMIL" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31630</SeqNum>
    <Name>L230.Elmont-Hanover-FourRivers.2032</Name>
    <LastEdit Timestamp="2024-11-07T10:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="20322103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="203292" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMONT4" b2="230 KV" b3="2032A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="230 KV" b3="20322061" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="230 KV" b3="20322067" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOURRIVR" b2="230 KV" b3="2032B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HANOVER4" b2="35 KV" b3="TX1LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="HANOVER4" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HANOVER4" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HANOVER4" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31650</SeqNum>
    <Name>L230.Earleys-Cashie-Trowbridge.2034</Name>
    <LastEdit Timestamp="2024-11-15T15:26:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CASHIE" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CASHIE" b2="230 KV" b3="TX1XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="203462" />
      <ContingencyEquipment Action="L" Type="LN" b1="CASHIE" b2="230 KV" b3="2034A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="246T2034" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="230 KV" b3="20342126" />
      <ContingencyEquipment Action="L" Type="LN" b1="TROWBRDG" b2="230 KV" b3="2034B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="230 KV" b3="H2T2034" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31660</SeqNum>
    <Name>L230.Idylwood-Redfield-CIA.2035</Name>
    <LastEdit Timestamp="2026-01-07T09:26:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CIA" b2="230 KV" b3="20292035" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CIA" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CIA" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CIA" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CIA" b2="35 KV" b3="TX4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IDYLWOO4" b2="230 KV" b3="203512X" />
      <ContingencyEquipment Action="L" Type="LN" b1="CIA" b2="230 KV" b3="2035A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="IDYLWOO4" b2="230 KV" b3="2035B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDFIELD" b2="34.5 KV" b3="L132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REDFIELD" b2="34.5 KV" b3="LOAD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="REDFIELD" b2="34.5 KV" b3="SC1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="REDFIELD" b2="34.5 KV" b3="SC2" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDFIELD" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31670</SeqNum>
    <Name>L230.Glebe-RadnorHeights.2036A</Name>
    <LastEdit Timestamp="2025-12-17T16:59:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLEBE" b2="230 KV" b3="203692" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLEBE" b2="230 KV" b3="2036A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLEBE" b2="230 KV" b3="258T2036" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RADNORHT" b2="230 KV" b3="20362142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RADNORHT" b2="230 KV" b3="203642" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31680</SeqNum>
    <Name>L230.Glebe-Pentagon.2037</Name>
    <LastEdit Timestamp="2026-02-10T15:23:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLEBE" b2="230 KV" b3="203792" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLEBE" b2="230 KV" b3="2037A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLEBE" b2="230 KV" b3="248T2037" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="230 KV" b3="H322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="230 KV" b3="H422" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31690</SeqNum>
    <Name>L230.Greenwich-ReevesAve.2038</Name>
    <LastEdit Timestamp="2025-08-11T15:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="230 KV" b3="203852-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="230 KV" b3="203852-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENWCH" b2="230 KV" b3="2038A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="230 KV" b3="H4T2038" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="230 KV" b3="H5T2038" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31700</SeqNum>
    <Name>L230.MarshRun-Morrisville.2039</Name>
    <LastEdit Timestamp="2026-04-08T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHRUN" b2="230 KV" b3="203902" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARSHRUN" b2="230 KV" b3="2039A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHRUN" b2="230 KV" b3="280T2039" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="230 KV" b3="L1T2039" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="230 KV" b3="L2T2039" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31710</SeqNum>
    <Name>L230.MarshRun-Morrisville.2040</Name>
    <LastEdit Timestamp="2026-04-08T09:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHRUN" b2="230 KV" b3="204002" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHRUN" b2="230 KV" b3="299T2040" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORRISVL" b2="230 KV" b3="2040A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="230 KV" b3="L1T2040" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="230 KV" b3="L2T2040" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31720</SeqNum>
    <Name>L230.Hopewell-HCF.2041</Name>
    <LastEdit Timestamp="2025-10-21T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HCF" b2="230 KV" b3="GSU1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HCF" b2="230 KV" b3="GSU2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HCF" b2="230 KV" b3="GSU3" />
      <ContingencyEquipment Action="X" Type="XF" b1="HCF" b2="230 KV" b3="GSU4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HCF" b2="13.8 KV" b3="GT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HCF" b2="13.8 KV" b3="GT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HCF" b2="13.8 KV" b3="GT3" />
      <ContingencyEquipment Action="L" Type="LN" b1="HCF" b2="230 KV" b3="HCF-HOPE" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HCF" b2="13.8 KV" b3="ST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="20412215" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="204132" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31730</SeqNum>
    <Name>L230.Occoquan-FCWADP-OgdenMartin.2042</Name>
    <LastEdit Timestamp="2024-09-10T13:48:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FCWADP" b2="230 KV" b3="2042B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FCWADP" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FCWADP" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCCOQUAN" b2="230 KV" b3="20012042" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCCOQUAN" b2="230 KV" b3="20132042" />
      <ContingencyEquipment Action="L" Type="LN" b1="OCCOQUAN" b2="230 KV" b3="2042A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OCCOQUAN" b2="230 KV" b3="215T2042" />
      <ContingencyEquipment Action="X" Type="XF" b1="OGDENMTN" b2="230 KV" b3="GSU-A" />
      <ContingencyEquipment Action="X" Type="XF" b1="OGDENMTN" b2="230 KV" b3="GSU-B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OGDENMTN" b2="13.8 KV" b3="NUG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31740</SeqNum>
    <Name>L230.Hopewell-Polyester.2046</Name>
    <LastEdit Timestamp="2025-03-17T14:18:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="20462197" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="204632" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPEWEL4" b2="230 KV" b3="2046A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="POLYESTR" b2="13.8 KV" b3="G1" />
      <ContingencyEquipment Action="X" Type="XF" b1="POLYESTR" b2="230 KV" b3="GSU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POLYESTR" b2="230 KV" b3="RSST1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31750</SeqNum>
    <Name>L230.Surry-GravelNeck.2047 + GravelNeck.CT3&amp;4</Name>
    <LastEdit Timestamp="2026-04-09T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GRAVLNK" b2="230 KV" b3="2047A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRAVLNK" b2="13 KV" b3="GT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRAVLNK" b2="13 KV" b3="GT4" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRAVLNK" b2="230 KV" b3="TXG3" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRAVLNK" b2="230 KV" b3="TXG4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="204702" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="290T2047" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31760</SeqNum>
    <Name>L230.Surry-GravelNeck.2048 + GravelNeck.CT5&amp;6</Name>
    <LastEdit Timestamp="2026-04-09T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GRAVLNK" b2="230 KV" b3="2048A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRAVLNK" b2="13 KV" b3="GT5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRAVLNK" b2="13 KV" b3="GT6" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRAVLNK" b2="230 KV" b3="TXG5" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRAVLNK" b2="230 KV" b3="TXG6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="204802" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="223T2048" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31770</SeqNum>
    <Name>L230.Allied-NatWelders-Enon-Chesterfield.2049</Name>
    <LastEdit Timestamp="2025-11-17T11:56:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLIED" b2="230 KV" b3="20492050" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLIED" b2="230 KV" b3="204962" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLIED" b2="230 KV" b3="2049C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="204912" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="G7T2049" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENON4" b2="230 KV" b3="2049A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ENON4" b2="35 KV" b3="LD3" />
      <ContingencyEquipment Action="X" Type="XF" b1="ENON4" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ENON4" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ENON4" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="L" Type="LN" b1="NATWELDR" b2="230 KV" b3="2049B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NATWELDR" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31780</SeqNum>
    <Name>L230.Allied-Alpine-Ici-Chickahominy.2050</Name>
    <LastEdit Timestamp="2025-11-17T11:56:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLIED" b2="230 KV" b3="20492050" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLIED" b2="230 KV" b3="205062" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALPINE" b2="230 KV" b3="2050B" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALPINE" b2="230 KV" b3="2050C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALPINE" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALPINE" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALPINE" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALPINE" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALPINE" b2="13 KV" b3="TX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALPINE" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="20502075" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="205022" />
      <ContingencyEquipment Action="L" Type="LN" b1="ICI" b2="230 KV" b3="2050A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ICI" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ICI" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ICI" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ICI" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31790</SeqNum>
    <Name>L230.Lexington-CliftonForge.2052</Name>
    <LastEdit Timestamp="2026-04-08T09:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLIFTNFG" b2="230 KV" b3="2052A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTNFG" b2="138 KV" b3="L222" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLIFTNFG" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="230 KV" b3="205202" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31800</SeqNum>
    <Name>L230.Darbytown-Northeast.2053</Name>
    <LastEdit Timestamp="2026-04-07T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARBYTWN" b2="230 KV" b3="G12T2053" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARBYTWN" b2="230 KV" b3="G34T2053" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="230 KV" b3="205362CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEAST" b2="230 KV" b3="2053A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="230 KV" b3="H9T2053" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31810</SeqNum>
    <Name>230/115.Gordonsville.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-04-22T11:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GORDONSV" b2="230 KV" b3="H184M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONSV" b2="115 KV" b3="L182" />
      <ContingencyEquipment Action="X" Type="XF" b1="GORDONSV" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31840</SeqNum>
    <Name>L230.Hornertown-Rosemary.2057 + Rosemary.NUG</Name>
    <LastEdit Timestamp="2026-04-09T15:02:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HORNERTN" b2="230 KV" b3="2057A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORNERTN" b2="230 KV" b3="239T2057" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSEMARY" b2="230 KV" b3="205702" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSEMARY" b2="230 KV" b3="52-G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSEMARY" b2="230 KV" b3="52-G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSEMARY" b2="230 KV" b3="52-STG" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROSEMARY" b2="230 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROSEMARY" b2="13.8 KV" b3="NUG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31870</SeqNum>
    <Name>FourRivers.CC5</Name>
    <LastEdit Timestamp="2026-04-09T14:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="230 KV" b3="20322061" />
      <ContingencyEquipment Action="S" Type="SD" b1="FOURRIVR" b2="230 KV" b3="20612" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="230 KV" b3="256T2061" />
      <ContingencyEquipment Action="X" Type="XF" b1="FOURRIVR" b2="230 KV" b3="GSUGT501" />
      <ContingencyEquipment Action="X" Type="XF" b1="FOURRIVR" b2="230 KV" b3="GSUGT502" />
      <ContingencyEquipment Action="X" Type="XF" b1="FOURRIVR" b2="230 KV" b3="GSUST501" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOURRIVR" b2="13.8 KV" b3="GT501" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOURRIVR" b2="13.8 KV" b3="GT502" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOURRIVR" b2="13.8 KV" b3="ST501" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31880</SeqNum>
    <Name>L230.Dranesville-Reston.2062</Name>
    <LastEdit Timestamp="2024-08-19T12:36:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DRANESVL" b2="230 KV" b3="20622079" />
      <ContingencyEquipment Action="L" Type="LN" b1="DRANESVL" b2="230 KV" b3="2062A" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DRANESVL" b2="230 KV" b3="SC5" />
      <ContingencyEquipment Action="X" Type="XF" b1="DRANESVL" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DRANESVL" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RESTON" b2="230 KV" b3="20102062" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RESTON" b2="230 KV" b3="20432062" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31890</SeqNum>
    <Name>L230.KittyHawk-Shawboro.2064</Name>
    <LastEdit Timestamp="2026-04-09T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="230 KV" b3="206452" />
      <ContingencyEquipment Action="L" Type="LN" b1="KITTYHWK" b2="230 KV" b3="2064A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="230 KV" b3="H752" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="230 KV" b3="XT2064" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWBORO" b2="230 KV" b3="20642192" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWBORO" b2="230 KV" b3="269T2064" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31900</SeqNum>
    <Name>L230.Basin-Spruance.2065</Name>
    <LastEdit Timestamp="2026-02-11T06:33:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASIN" b2="230 KV" b3="206542" />
      <ContingencyEquipment Action="L" Type="LN" b1="BASIN" b2="230 KV" b3="2065A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRUANCE" b2="230 KV" b3="282T2065" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRUANCE" b2="230 KV" b3="AUX3LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRUANCE" b2="230 KV" b3="AUX4LD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPRUANCE" b2="13.8 KV" b3="G2-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPRUANCE" b2="13.8 KV" b3="G2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRUANCE" b2="230 KV" b3="G34T2065" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPRUANCE" b2="230 KV" b3="GSUG3" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPRUANCE" b2="230 KV" b3="GSUG4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31910</SeqNum>
    <Name>L230.Midlothian-Trabue-Genito-Winterpock.2066</Name>
    <LastEdit Timestamp="2026-06-09T07:08:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GENITO" b2="230 KV" b3="GEN-TRAB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GENITO" b2="230 KV" b3="GEN-WINT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GENITO" b2="230 KV" b3="H142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLOTH" b2="230 KV" b3="20092066" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLOTH" b2="230 KV" b3="223612" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRABUE4" b2="230 KV" b3="2066A" />
      <ContingencyEquipment Action="X" Type="XF" b1="TRABUE4" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRABUE4" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="TRABUE4" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRABUE4" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERPK" b2="230 KV" b3="H14T2066" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERPK" b2="230 KV" b3="H23T2066" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31930</SeqNum>
    <Name>L230.ElizabethRiver-Yadkin.2070</Name>
    <LastEdit Timestamp="2026-04-09T14:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZRIV" b2="230 KV" b3="20182070" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZRIV" b2="230 KV" b3="20702071" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELIZRIV" b2="230 KV" b3="SS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="207012" />
      <ContingencyEquipment Action="L" Type="LN" b1="YADKIN4" b2="230 KV" b3="2070A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="223T2070" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31940</SeqNum>
    <Name>L230.ElizabethRiver-NUG.2071 + ElizRiv.CT1-3</Name>
    <LastEdit Timestamp="2026-04-09T15:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZRIV" b2="230 KV" b3="20182071" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZRIV" b2="230 KV" b3="20702071" />
      <ContingencyEquipment Action="S" Type="SD" b1="ELIZRIV" b2="230 KV" b3="2071Z" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELIZRIV" b2="230 KV" b3="GSU01" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELIZRIV" b2="230 KV" b3="GSU02" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELIZRIV" b2="230 KV" b3="GSU03" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ELIZRIV" b2="13.8 KV" b3="GT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ELIZRIV" b2="13.8 KV" b3="GT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ELIZRIV" b2="13.8 KV" b3="GT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31950</SeqNum>
    <Name>L230.KittyHawk-PointHarbor-Aydlett-Shawboro.2073</Name>
    <LastEdit Timestamp="2026-04-09T15:00:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="AYDLETT" b2="230 KV" b3="20732136" />
      <ContingencyEquipment Action="L" Type="LN" b1="AYDLETT" b2="230 KV" b3="2073A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="230 KV" b3="207352" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="230 KV" b3="H352" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="230 KV" b3="XT2073" />
      <ContingencyEquipment Action="L" Type="LN" b1="AYDLETT" b2="230 KV" b3="2073BNEW" />
      <ContingencyEquipment Action="L" Type="LN" b1="POINTHBR" b2="230 KV" b3="2073C" />
      <ContingencyEquipment Action="X" Type="XF" b1="POINTHBR" b2="230 KV" b3="TX 1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POINTHBR" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWBORO" b2="230 KV" b3="20212073" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWBORO" b2="230 KV" b3="20732192" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31960</SeqNum>
    <Name>L230.LouisaCT-SouthAnna.2074 + SouthAnna.G1</Name>
    <LastEdit Timestamp="2025-05-15T09:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LOUISACT" b2="230 KV" b3="2074A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISACT" b2="230 KV" b3="G12T2074" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISACT" b2="230 KV" b3="G5T2074" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANNA" b2="230 KV" b3="20742202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANNA" b2="230 KV" b3="52G1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANNA" b2="230 KV" b3="52G1B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SANNA" b2="230 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANNA" b2="230 KV" b3="G1T2074" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31970</SeqNum>
    <Name>L230.Elmont-Pearson-OldChurch-Chickahominy.2075</Name>
    <LastEdit Timestamp="2026-02-19T10:34:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="20502075" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="207522" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICKHOM" b2="230 KV" b3="2075C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="207592" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="216T2075" />
      <ContingencyEquipment Action="X" Type="XF" b1="OLDCHRCH" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OLDCHRCH" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="OLDCHRCH" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OLDCHRCH" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PEARSON" b2="230 KV" b3="2075A" />
      <ContingencyEquipment Action="L" Type="LN" b1="PEARSON" b2="230 KV" b3="2075B" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEARSON" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEARSON" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31980</SeqNum>
    <Name>L230.Dahlgren-OakGrv-Wmorelnd-Sander-NrthNeck.2076</Name>
    <LastEdit Timestamp="2025-09-03T10:51:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAHLGREN" b2="230 KV" b3="207682-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAHLGREN" b2="230 KV" b3="207682-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="230 KV" b3="20762208" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="230 KV" b3="207652CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="NRTHNECK" b2="230 KV" b3="2076D" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAHLGREN" b2="230 KV" b3="2076B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WMORELN4" b2="230 KV" b3="2076C" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKGROV4" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKGROV4" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKGROV4" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKGROV4" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SANDERDP" b2="230 KV" b3="2076C1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SANDERDP" b2="34.5 KV" b3="TX3LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="SANDERDP" b2="230 KV" b3="TX_1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WMORELN4" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WMORELN4" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>31990</SeqNum>
    <Name>L230.SewellsPoint-NavySth-NavyNrth.2082+Sewell.TX6</Name>
    <LastEdit Timestamp="2026-04-02T09:20:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NAVYNTH" b2="230 KV" b3="20822093" />
      <ContingencyEquipment Action="L" Type="LN" b1="NAVYNTH" b2="230 KV" b3="2082B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NAVYNTH" b2="230 KV" b3="SC3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NAVYNTH" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAVYSTH" b2="230 KV" b3="2082T209" />
      <ContingencyEquipment Action="X" Type="XF" b1="NAVYSTH" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NAVYSTH" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="230 KV" b3="20822099" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEWELLPT" b2="230 KV" b3="2082A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="230 KV" b3="257T2082" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="115 KV" b3="L672" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEWELLPT" b2="230 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32000</SeqNum>
    <Name>L230.Fredericksburg-Birchwood.2083</Name>
    <LastEdit Timestamp="2025-10-24T20:09:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIRCHWD" b2="230 KV" b3="208312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRDRKSBG" b2="230 KV" b3="20832301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRDRKSBG" b2="230 KV" b3="208342" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRDRKSBG" b2="230 KV" b3="2083A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32020</SeqNum>
    <Name>L230.RemingtonCT-Warrenton.2086</Name>
    <LastEdit Timestamp="2024-11-05T14:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="20772086" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="208662" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRENTN" b2="230 KV" b3="20862155" />
      <ContingencyEquipment Action="L" Type="LN" b1="WARRENTN" b2="230 KV" b3="2086A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRENTN" b2="230 KV" b3="H252CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WARRENTN" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WARRENTN" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32050</SeqNum>
    <Name>L230.Chickahominy-Elko-Portugee.2091</Name>
    <LastEdit Timestamp="2024-10-25T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="20242091" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="209122" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICKHOM" b2="230 KV" b3="2091A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKO4" b2="230 KV" b3="2091B2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELKO4" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELKO4" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUGEE" b2="230 KV" b3="209172-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUGEE" b2="230 KV" b3="209172-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32060</SeqNum>
    <Name>L230.SewellsPoint-NavyNorth.2093</Name>
    <LastEdit Timestamp="2026-04-09T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NAVYNTH" b2="230 KV" b3="20822093" />
      <ContingencyEquipment Action="L" Type="LN" b1="NAVYNTH" b2="230 KV" b3="2093B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NAVYNTH" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAVYSTH" b2="230 KV" b3="2082T209" />
      <ContingencyEquipment Action="X" Type="XF" b1="NAVYSTH" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NAVYSTH" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEWELLPT" b2="230 KV" b3="2093A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="230 KV" b3="257T2093" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="230 KV" b3="H5T2093" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="230 KV" b3="H872" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEWELLPT" b2="230 KV" b3="TX8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SEWELLPT" b2="35 KV" b3="TX8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32070</SeqNum>
    <Name>L230.Ox-Idylwood.2097</Name>
    <LastEdit Timestamp="2026-01-07T09:29:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="IDYLWOO4" b2="230 KV" b3="2097A" />
      <ContingencyEquipment Action="X" Type="XF" b1="GALLWSRD" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GALLWSRD" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IDYLWOO4" b2="230 KV" b3="209712X" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="209742" />
      <ContingencyEquipment Action="L" Type="LN" b1="OX4" b2="230 KV" b3="2097B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="243T2097" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32100</SeqNum>
    <Name>BathCounty.U1</Name>
    <LastEdit Timestamp="2024-12-03T08:31:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="20 KV" b3="552GM-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BATHCO" b2="20 KV" b3="GM1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32110</SeqNum>
    <Name>BathCounty.U2</Name>
    <LastEdit Timestamp="2024-12-03T08:31:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="20 KV" b3="552GM-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BATHCO" b2="20 KV" b3="GM2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32120</SeqNum>
    <Name>BathCounty.U3</Name>
    <LastEdit Timestamp="2024-12-03T08:32:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="20 KV" b3="552GM-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BATHCO" b2="20 KV" b3="GM3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32130</SeqNum>
    <Name>BathCounty.U4</Name>
    <LastEdit Timestamp="2024-12-03T08:32:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="20 KV" b3="552GM-4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BATHCO" b2="20 KV" b3="GM4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32140</SeqNum>
    <Name>BathCounty.U5</Name>
    <LastEdit Timestamp="2024-12-03T08:32:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="20 KV" b3="552GM-5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BATHCO" b2="20 KV" b3="GM5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32150</SeqNum>
    <Name>BathCounty.U6</Name>
    <LastEdit Timestamp="2026-03-10T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="20 KV" b3="552GM-6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BATHCO" b2="20 KV" b3="GM6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32160</SeqNum>
    <Name>230/115.Bremo.TX9</Name>
    <LastEdit Timestamp="2026-04-08T09:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="230 KV" b3="H922" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="115 KV" b3="L922" />
      <ContingencyEquipment Action="X" Type="XF" b1="BREMO4" b2="230 KV" b3="TX9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32170</SeqNum>
    <Name>230/115.Basin.TX5</Name>
    <LastEdit Timestamp="2026-04-08T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASIN" b2="230 KV" b3="H542" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASIN" b2="115 KV" b3="L542" />
      <ContingencyEquipment Action="X" Type="XF" b1="BASIN" b2="230 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32190</SeqNum>
    <Name>230/115.BullRun.TX3</Name>
    <LastEdit Timestamp="2024-12-18T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRUN" b2="230 KV" b3="H362" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRUN" b2="115 KV" b3="L362" />
      <ContingencyEquipment Action="X" Type="XF" b1="BULLRUN" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32210</SeqNum>
    <Name>Chesterfield.U6</Name>
    <LastEdit Timestamp="2026-02-11T06:47:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESTER4" b2="22 KV" b3="G6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="G612" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="G6T211" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHESTER4" b2="4 KV" b3="SS6LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTER4" b2="230 KV" b3="TG6A" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTER4" b2="230 KV" b3="TG6B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32220</SeqNum>
    <Name>230/115.Chesterfield.TX9</Name>
    <LastEdit Timestamp="2026-04-08T11:10:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="G8TH9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="H912" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="115 KV" b3="L92-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="115 KV" b3="L92-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTER4" b2="230 KV" b3="RS6A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHESTER4" b2="4 KV" b3="RS6A" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTER4" b2="230 KV" b3="RS6B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHESTER4" b2="4 KV" b3="RS6BLD" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTER4" b2="230 KV" b3="TX9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32230</SeqNum>
    <Name>Clover.U1</Name>
    <LastEdit Timestamp="2026-02-11T06:35:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="25 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G1T2068" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVER" b2="25 KV" b3="SS1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOVER" b2="7 KV" b3="SS1LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVER" b2="230 KV" b3="TXG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32240</SeqNum>
    <Name>Clover.U2</Name>
    <LastEdit Timestamp="2026-02-11T06:36:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="25 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G2TL9" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVER" b2="25 KV" b3="SS2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOVER" b2="7 KV" b3="SS2LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVER" b2="230 KV" b3="TXG2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32250</SeqNum>
    <Name>230/115.Dooms.TX6</Name>
    <LastEdit Timestamp="2026-04-08T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="H642" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="115 KV" b3="L642" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOOMS4" b2="230 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32260</SeqNum>
    <Name>230/115.Dooms.TX8</Name>
    <LastEdit Timestamp="2026-04-08T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="27242" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="272T291" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="115 KV" b3="L842-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="115 KV" b3="L842-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOOMS4" b2="230 KV" b3="TX8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32310</SeqNum>
    <Name>230/115.Elmont.TX5</Name>
    <LastEdit Timestamp="2026-04-09T14:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="H592CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="115 KV" b3="L592" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELMONT4" b2="230 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32320</SeqNum>
    <Name>230/115.Earleys.TX3</Name>
    <LastEdit Timestamp="2026-04-10T14:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="H362" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="115 KV" b3="L362" />
      <ContingencyEquipment Action="X" Type="XF" b1="EARLEYS" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32400</SeqNum>
    <Name>L115.Chesterfield-Walthall-Harrowgate-Locks.100</Name>
    <LastEdit Timestamp="2026-04-10T14:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="115 KV" b3="10012" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARWGATE" b2="115 KV" b3="100J" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARWGATE" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARWGATE" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARWGATE" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARWGATE" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKS" b2="115 KV" b3="10022" />
      <ContingencyEquipment Action="L" Type="LN" b1="WALTHALL" b2="115 KV" b3="100A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WALTHALL" b2="115 KV" b3="100I" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALTHALL" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALTHALL" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALTHALL" b2="115 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32410</SeqNum>
    <Name>L115.Dooms-BrandDP-Staunton.102</Name>
    <LastEdit Timestamp="2026-04-10T14:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRANDDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="115 KV" b3="10242" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOOMS4" b2="115 KV" b3="102A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAUNTON" b2="115 KV" b3="10272" />
      <ContingencyEquipment Action="L" Type="LN" b1="STAUNTON" b2="115 KV" b3="102B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAUNTON" b2="115 KV" b3="L6T102" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32420</SeqNum>
    <Name>L138.Altavista-Leesville.104</Name>
    <LastEdit Timestamp="2026-04-10T14:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAVSTA" b2="138 KV" b3="10432" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEESVILL" b2="138 KV" b3="LEE-ALT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESVILL" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32430</SeqNum>
    <Name>L115.Poe-NewBohemiaSub-NewBohemiaDP-Harrell.106</Name>
    <LastEdit Timestamp="2026-04-10T14:42:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAKRSPDP" b2="115 KV" b3="106AB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BAKRSPDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRELL" b2="115 KV" b3="10642-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRELL" b2="115 KV" b3="10642-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAKRSPDP" b2="115 KV" b3="BAK-HARR" />
      <ContingencyEquipment Action="L" Type="LN" b1="NBOHEMDP" b2="115 KV" b3="106A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NBOHEMDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NBOHMSUB" b2="115 KV" b3="SC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POE" b2="115 KV" b3="10652" />
      <ContingencyEquipment Action="L" Type="LN" b1="NBOHMSUB" b2="115 KV" b3="106A2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32440</SeqNum>
    <Name>L115.Oakwood-Taussig-SewellsPointT.107</Name>
    <LastEdit Timestamp="2025-07-14T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKWOOD" b2="115 KV" b3="10762" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKWOOD" b2="115 KV" b3="107A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="115 KV" b3="48T107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="115 KV" b3="L672" />
      <ContingencyEquipment Action="L" Type="LN" b1="TAUSSIG" b2="115 KV" b3="107B" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAUSSIG" b2="115 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TAUSSIG" b2="35 KV" b3="TX4" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAUSSIG" b2="115 KV" b3="TX5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TAUSSIG" b2="34.5 KV" b3="TX5" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAUSSIG" b2="115 KV" b3="TX6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TAUSSIG" b2="34 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32450</SeqNum>
    <Name>L115.Boykins-Murphy-Mapleton-Tunis.108</Name>
    <LastEdit Timestamp="2024-11-18T13:09:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOYKINS" b2="115 KV" b3="10832" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOYKINS" b2="115 KV" b3="108A" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAPLTNDP" b2="115 KV" b3="108B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAPLTNDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MURPHY" b2="115 KV" b3="H122CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MURPHY" b2="115 KV" b3="H222" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MURPHY" b2="35 KV" b3="MURFRESP" />
      <ContingencyEquipment Action="X" Type="XF" b1="MURPHY" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MURPHY" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MURPHY" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MURPHY" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAPLTNDP" b2="115 KV" b3="108C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNIS" b2="115 KV" b3="108T136" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="TUNIS" b2="115 KV" b3="SC1" />
      <ContingencyEquipment Action="X" Type="XF" b1="TUNIS" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TUNIS" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32460</SeqNum>
    <Name>L138.Eastmill-WestVaco.109</Name>
    <LastEdit Timestamp="2026-04-10T14:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTMILL" b2="138 KV" b3="10992" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTMILL" b2="138 KV" b3="109A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTVAC4" b2="138 KV" b3="10982" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32470</SeqNum>
    <Name>L138.Lowmoor-Covington-FudgeHollow.112</Name>
    <LastEdit Timestamp="2026-04-10T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COVINGTN" b2="138 KV" b3="112A" />
      <ContingencyEquipment Action="X" Type="XF" b1="COVINGTN" b2="138 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COVINGTN" b2="46 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FUDGEHO4" b2="138 KV" b3="112B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FUDGEHO4" b2="138 KV" b3="112T155" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FUDGEHO4" b2="138 KV" b3="14T112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWMOOR" b2="138 KV" b3="H12T112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWMOOR" b2="138 KV" b3="L34T112" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32480</SeqNum>
    <Name>L115.Battleboro-RockyMount.123</Name>
    <LastEdit Timestamp="2025-12-04T16:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="3ROCKY" b2="115 KV" b3="123A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3ROCKY" b2="115 KV" b3="6BAT_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATTLEBO" b2="115 KV" b3="12342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATTLEBO" b2="115 KV" b3="H342" />
      <ContingencyEquipment Action="X" Type="XF" b1="BATTLEBO" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BATTLEBO" b2="35 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32490</SeqNum>
    <Name>L115.Earleys-Kelford-SamsHead-ScotlandNeck.126</Name>
    <LastEdit Timestamp="2025-06-12T11:13:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="115 KV" b3="12662" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="115 KV" b3="126T136" />
      <ContingencyEquipment Action="L" Type="LN" b1="KELFORD" b2="115 KV" b3="126A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KELFORD" b2="35 KV" b3="KELFRDSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="KELFORD" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KELFORD" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="KELFORD" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAMSHEAD" b2="115 KV" b3="126B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SAMSHEAD" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCOTLAND" b2="115 KV" b3="126C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOTLAND" b2="115 KV" b3="126T1070" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32500</SeqNum>
    <Name>L115.BuggsIsland-Kndrtn-Omega-ReedyCr-Plywood.127</Name>
    <LastEdit Timestamp="2025-12-03T11:53:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BUGGSISL" b2="115 KV" b3="127E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUGGSISL" b2="115 KV" b3="127T193" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUGGSISL" b2="115 KV" b3="36T127" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLARKVIL" b2="115 KV" b3="127C" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINDERTN" b2="115 KV" b3="127D" />
      <ContingencyEquipment Action="X" Type="XF" b1="KINDERTN" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINDERTN" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OMEGADP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLYWOOD" b2="115 KV" b3="127A_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYWOOD" b2="115 KV" b3="127T151" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYWOOD" b2="115 KV" b3="G1T127" />
      <ContingencyEquipment Action="L" Type="LN" b1="REEDYCRK" b2="115 KV" b3="127B" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="REEDYCRK" b2="115 KV" b3="32T127" />
      <ContingencyEquipment Action="X" Type="XF" b1="REEDYCRK" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REEDYCRK" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32510</SeqNum>
    <Name>L115.Edinburg-EndlessCaverns.128</Name>
    <LastEdit Timestamp="2025-07-28T18:12:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDINBUR4" b2="115 KV" b3="12812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDINBUR4" b2="115 KV" b3="H112" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDINBUR4" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDINBUR4" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="115 KV" b3="118T128" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="115 KV" b3="12852" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTJACKS4" b2="115 KV" b3="128A" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTJACKS4" b2="115 KV" b3="128B" />
      <ContingencyEquipment Action="X" Type="XF" b1="MTJACKS4" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTJACKS4" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTJACKS4" b2="115 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32520</SeqNum>
    <Name>L115.Cradock-Reeves Ave.129</Name>
    <LastEdit Timestamp="2026-04-10T14:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRADOCK" b2="115 KV" b3="12932" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="115 KV" b3="12912" />
      <ContingencyEquipment Action="L" Type="LN" b1="REEVESAV" b2="115 KV" b3="129A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32530</SeqNum>
    <Name>L115.Carolina-Sockman-PleasantHillTap-Skippers.130</Name>
    <LastEdit Timestamp="2025-10-02T10:41:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAROLINA" b2="115 KV" b3="13002" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CAROLINA" b2="115 KV" b3="13008" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAROLINA" b2="115 KV" b3="CAR-SOCK" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLESNTH4" b2="115 KV" b3="130AB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLESNTH4" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLSNTHTP" b2="115 KV" b3="PLE-SOCK" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLSNTHTP" b2="115 KV" b3="PLS-SKIP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKIPPERS" b2="115 KV" b3="13012" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKIPPERS" b2="115 KV" b3="130T1043" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOCKMAN" b2="115 KV" b3="H182" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOCKMAN" b2="36.5 KV" b3="LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="SOCKMAN" b2="115 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32540</SeqNum>
    <Name>L138.Lowmoor-Alleghany-Clifton Forge.133</Name>
    <LastEdit Timestamp="2026-03-30T18:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLEGHAN" b2="138 KV" b3="ALL-CLIF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLEGHAN" b2="138 KV" b3="H242" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLEGHAN" b2="13 KV" b3="LD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALLEGHAN" b2="138 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTNFG" b2="138 KV" b3="13322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWMOOR" b2="138 KV" b3="133T161" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLEGHAN" b2="138 KV" b3="ALL-LOWM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWMOOR" b2="138 KV" b3="H12T133" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32550</SeqNum>
    <Name>L115.Greenwich-TholeSt.135</Name>
    <LastEdit Timestamp="2025-04-07T15:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GREENWCH" b2="115 KV" b3="135A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="115 KV" b3="135T166" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="115 KV" b3="67T135" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GREENWCH" b2="115 KV" b3="SC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOLEST" b2="115 KV" b3="135T182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOLEST" b2="115 KV" b3="135T196" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32560</SeqNum>
    <Name>L115.Earleys-Ahoskie-Tunis.136</Name>
    <LastEdit Timestamp="2026-04-10T14:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AHOSKIE" b2="115 KV" b3="136B" />
      <ContingencyEquipment Action="X" Type="XF" b1="AHOSKIE" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AHOSKIE" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="AHOSKIE" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AHOSKIE" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="115 KV" b3="126T136" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="115 KV" b3="13662" />
      <ContingencyEquipment Action="L" Type="LN" b1="EARLEYS" b2="115 KV" b3="136A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNIS" b2="115 KV" b3="108T136" />
      <ContingencyEquipment Action="X" Type="XF" b1="TUNIS" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TUNIS" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32580</SeqNum>
    <Name>L115.BalconyFalls-Skimmer.141</Name>
    <LastEdit Timestamp="2025-05-29T14:26:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BALCFALL" b2="115 KV" b3="26T141CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALCFALL" b2="115 KV" b3="28T141CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKIMMER4" b2="115 KV" b3="14162" />
      <ContingencyEquipment Action="L" Type="LN" b1="SKIMMER4" b2="115 KV" b3="141A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32590</SeqNum>
    <Name>L115.Elmont-Northwest.142</Name>
    <LastEdit Timestamp="2026-04-10T14:36:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="115 KV" b3="14292" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMONT4" b2="115 KV" b3="142A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELMONT4" b2="115 KV" b3="59T142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWEST" b2="115 KV" b3="14252" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32600</SeqNum>
    <Name>L115.Landstown-PrincAnn-LondonBridge-Pendleton.147</Name>
    <LastEdit Timestamp="2026-03-04T10:10:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LANDSTWN" b2="115 KV" b3="147A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="115 KV" b3="L1T147" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="115 KV" b3="L2T147" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONDNBRG" b2="115 KV" b3="147B" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONDNBRG" b2="115 KV" b3="147C" />
      <ContingencyEquipment Action="X" Type="XF" b1="LONDNBRG" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LONDNBRG" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENDLETN" b2="115 KV" b3="78T147" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENDLETN" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENDLETN" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PRINCANN" b2="36.5 KV" b3="LD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="PRINCANN" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PRINCANN" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PRINCANN" b2="115 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32610</SeqNum>
    <Name>L115.Basin-TwelfthStreet.150</Name>
    <LastEdit Timestamp="2026-04-10T14:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASIN" b2="115 KV" b3="15042" />
      <ContingencyEquipment Action="L" Type="LN" b1="TWELFTHS" b2="115 KV" b3="150A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWELFTHS" b2="115 KV" b3="H6T150" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWELFTHS" b2="115 KV" b3="H7T150" />
      <ContingencyEquipment Action="X" Type="XF" b1="TWELFTHS" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TWELFTHS" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32620</SeqNum>
    <Name>L138.FudgeHollow-WestVaco.155</Name>
    <LastEdit Timestamp="2026-04-10T14:43:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FUDGEHO4" b2="138 KV" b3="112T155" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FUDGEHO4" b2="138 KV" b3="14T155" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTVAC4" b2="138 KV" b3="15582" />
      <ContingencyEquipment Action="L" Type="LN" b1="WESTVAC4" b2="138 KV" b3="155A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32640</SeqNum>
    <Name>L115.Plaza-Manchester.157</Name>
    <LastEdit Timestamp="2026-04-10T14:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MANCHSTR" b2="115 KV" b3="15732-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANCHSTR" b2="115 KV" b3="15732-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANCHSTR" b2="115 KV" b3="157A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLAZA" b2="115 KV" b3="15722" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32650</SeqNum>
    <Name>L115.Lowmoor-Eastmill.161</Name>
    <LastEdit Timestamp="2026-04-10T14:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COVINGTN" b2="138 KV" b3="161A" />
      <ContingencyEquipment Action="L" Type="LN" b1="COVINGTN" b2="138 KV" b3="161B" />
      <ContingencyEquipment Action="X" Type="XF" b1="COVINGTN" b2="138 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COVINGTN" b2="46 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTMILL" b2="138 KV" b3="16192" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWMOOR" b2="138 KV" b3="133T161" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWMOOR" b2="138 KV" b3="L34T161" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32660</SeqNum>
    <Name>L115.Locks-Harvell.162</Name>
    <LastEdit Timestamp="2026-04-10T14:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVELL" b2="115 KV" b3="16242" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKS" b2="115 KV" b3="16222" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOCKS" b2="115 KV" b3="162A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32670</SeqNum>
    <Name>L115.Chesapeake-ReevesAvenue.164</Name>
    <LastEdit Timestamp="2026-04-10T14:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="115 KV" b3="16422" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHESAPKE" b2="115 KV" b3="16428" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESAPKE" b2="115 KV" b3="164A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="115 KV" b3="16412" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32680</SeqNum>
    <Name>L115.Shellbank-Whealton.165</Name>
    <LastEdit Timestamp="2026-04-10T14:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELLBNK" b2="115 KV" b3="16552" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHELLBNK" b2="115 KV" b3="165A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEALTON" b2="115 KV" b3="16542" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32690</SeqNum>
    <Name>FourRivers.U1</Name>
    <LastEdit Timestamp="2024-12-12T10:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="115 KV" b3="175T1008" />
      <ContingencyEquipment Action="S" Type="SD" b1="FOURRIVR" b2="115 KV" b3="175Z" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="115 KV" b3="73T175" />
      <ContingencyEquipment Action="X" Type="XF" b1="FOURRIVR" b2="115 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOURRIVR" b2="18 KV" b3="NUG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32700</SeqNum>
    <Name>L115.IndustrialPark-Thole St.182</Name>
    <LastEdit Timestamp="2026-04-10T14:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDUSTPK" b2="115 KV" b3="18242" />
      <ContingencyEquipment Action="L" Type="LN" b1="INDUSTPK" b2="115 KV" b3="182A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOLEST" b2="115 KV" b3="135T182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOLEST" b2="115 KV" b3="48T182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOLEST" b2="115 KV" b3="H122" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THOLEST" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32710</SeqNum>
    <Name>L115.PossumPt-CountryClub-Smoketown.145</Name>
    <LastEdit Timestamp="2025-01-31T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CTRYCLDP" b2="115 KV" b3="CTR-SMOK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CTRYCLDP" b2="115 KV" b3="H30BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CTRYCLDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CTRYCLDP" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="115 KV" b3="14592" />
      <ContingencyEquipment Action="L" Type="LN" b1="POSSUMP4" b2="115 KV" b3="145A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMOKTNDP" b2="115 KV" b3="14556" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32720</SeqNum>
    <Name>L115.Altavista-Hallbranch-Hurt.191</Name>
    <LastEdit Timestamp="2025-11-11T10:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAVSTA" b2="115 KV" b3="19132" />
      <ContingencyEquipment Action="L" Type="LN" b1="HALLBRAN" b2="115 KV" b3="191A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HALLBRAN" b2="13.8 KV" b3="G1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HALLBRAN" b2="115 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32730</SeqNum>
    <Name>L115.Kerrdam-IslandCreek-ClarkvDP-BuggsIsland.193</Name>
    <LastEdit Timestamp="2025-10-10T12:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUGGSISL" b2="115 KV" b3="127T193" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUGGSISL" b2="115 KV" b3="19312" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUGGSISL" b2="115 KV" b3="193A1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BURDRTP" b2="115 KV" b3="36T193" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURDRTP" b2="115 KV" b3="BUR-BURL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BURDRTP" b2="115 KV" b3="LOAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURLNGTP" b2="115 KV" b3="BUR-CLA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURLNGTP" b2="115 KV" b3="BUR-CLA2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLARKVDP" b2="115 KV" b3="TX1LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="ISLCRKDP" b2="115 KV" b3="193B" />
      <ContingencyEquipment Action="L" Type="LN" b1="ISLCRKDP" b2="115 KV" b3="193C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ISLCRKDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KERRDAM" b2="115 KV" b3="193D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="25" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KERRDP" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32740</SeqNum>
    <Name>L115.Lexington-Fairfield.194</Name>
    <LastEdit Timestamp="2026-04-10T14:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUSTLEDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAIRFELD" b2="115 KV" b3="194B" />
      <ContingencyEquipment Action="X" Type="XF" b1="FAIRFELD" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FAIRFELD" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEXINGTN" b2="115 KV" b3="194A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="115 KV" b3="9T194" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="115 KV" b3="L2T194" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32750</SeqNum>
    <Name>L115.Oakwood-TholeStreet.196</Name>
    <LastEdit Timestamp="2026-04-10T14:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKWOOD" b2="115 KV" b3="19662" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKWOOD" b2="115 KV" b3="196A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOLEST" b2="115 KV" b3="135T196" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOLEST" b2="115 KV" b3="48T196" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="THOLEST" b2="115 KV" b3="SC2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32760</SeqNum>
    <Name>L230.BullRun-Pender.200</Name>
    <LastEdit Timestamp="2026-04-10T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BULLRUN" b2="230 KV" b3="200A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRUN" b2="230 KV" b3="200T244" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRUN" b2="230 KV" b3="200T295" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENDER" b2="230 KV" b3="200T2051" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENDER" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENDER" b2="35 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32770</SeqNum>
    <Name>L230.Clark-Idylwood.202</Name>
    <LastEdit Timestamp="2026-01-07T09:12:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARK4" b2="230 KV" b3="202T2005" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARK4" b2="230 KV" b3="202T2033" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLARK4" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLARK4" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IDYLWOO4" b2="230 KV" b3="20212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IDYLWOO4" b2="230 KV" b3="2022175X" />
      <ContingencyEquipment Action="L" Type="LN" b1="IDYLWOO4" b2="230 KV" b3="202A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32780</SeqNum>
    <Name>L230.GumSprings-Belvoir-JeffersonStreet.204</Name>
    <LastEdit Timestamp="2026-04-13T14:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELVOIR" b2="230 KV" b3="204A" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELVOIR" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELVOIR" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GUMSPRNG" b2="230 KV" b3="204B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUMSPRNG" b2="230 KV" b3="204T220" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUMSPRNG" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GUMSPRNG" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFRSON" b2="230 KV" b3="20422" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32790</SeqNum>
    <Name>L230.Chesterfield-Tyler-Harrowgate-Locks.205</Name>
    <LastEdit Timestamp="2024-11-08T09:53:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="20512" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTER4" b2="230 KV" b3="205A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="205T217" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARWGATE" b2="230 KV" b3="205C" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARWGATE" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARWGATE" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKS" b2="230 KV" b3="205T249" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKS" b2="230 KV" b3="H6T205" />
      <ContingencyEquipment Action="L" Type="LN" b1="TYLER" b2="230 KV" b3="205B" />
      <ContingencyEquipment Action="X" Type="XF" b1="TYLER" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TYLER" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32800</SeqNum>
    <Name>L230.Braddock-Idylwood.207</Name>
    <LastEdit Timestamp="2026-01-07T09:25:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADDOCK" b2="230 KV" b3="207T281" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADDOCK" b2="230 KV" b3="207T294" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IDYLWOO4" b2="230 KV" b3="20712X" />
      <ContingencyEquipment Action="L" Type="LN" b1="IDYLWOO4" b2="230 KV" b3="207A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32810</SeqNum>
    <Name>L230.Chesterfield-Southwest.208</Name>
    <LastEdit Timestamp="2024-05-14T09:57:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="20812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="208T287" />
      <ContingencyEquipment Action="L" Type="LN" b1="IRONBRI4" b2="230 KV" b3="208A" />
      <ContingencyEquipment Action="X" Type="XF" b1="IRONBRI4" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IRONBRI4" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="IRONBRI4" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IRONBRI4" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="L" Type="LN" b1="IRONBRI4" b2="230 KV" b3="IRO-SOUT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32830</SeqNum>
    <Name>L230.SkiffesCreek-Lebanon-Yorktown.209</Name>
    <LastEdit Timestamp="2024-10-28T12:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LEBANON4" b2="230 KV" b3="209B" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEBANON4" b2="230 KV" b3="209B1" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEBANON4" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEBANON4" b2="35 KV" b3="TX3LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="230 KV" b3="20972" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="230 KV" b3="209T2154" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="230 KV" b3="20982" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="230 KV" b3="209T285" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32840</SeqNum>
    <Name>L230.Hayfield-Vandorn.210</Name>
    <LastEdit Timestamp="2025-02-18T20:33:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HAYFIEL4" b2="230 KV" b3="210A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYFIEL4" b2="230 KV" b3="210T241" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAYFIEL4" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAYFIEL4" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYFIEL4" b2="230 KV" b3="XT210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VANDORN" b2="230 KV" b3="210T243" />
      <ContingencyEquipment Action="X" Type="XF" b1="VANDORN" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VANDORN" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32850</SeqNum>
    <Name>L230.Chesterfield-Hopewell.211</Name>
    <LastEdit Timestamp="2025-10-29T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="21112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="G6T211" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="21132" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPEWEL4" b2="230 KV" b3="211A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="211T2124" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32860</SeqNum>
    <Name>L230.Hopewell-ColonialTrail.2197</Name>
    <LastEdit Timestamp="2024-11-13T09:24:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLTRAIL" b2="230 KV" b3="219792" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLTRAIL" b2="230 KV" b3="XT2197" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="20462197" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="219732" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLTRAIL" b2="230 KV" b3="COL-HOPE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32870</SeqNum>
    <Name>L230.Thelma-Lakeview.213</Name>
    <LastEdit Timestamp="2025-11-03T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEVIE4" b2="230 KV" b3="21362" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEVIE4" b2="230 KV" b3="213T254" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEVIE4" b2="230 KV" b3="213_A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA4" b2="230 KV" b3="213T2244" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA4" b2="230 KV" b3="213T232" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32880</SeqNum>
    <Name>L230.Carolina-Lakeview.2141</Name>
    <LastEdit Timestamp="2026-04-29T17:44:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CAROLINA" b2="230 KV" b3="2141" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAROLINA" b2="230 KV" b3="H4T2141" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEVIE4" b2="230 KV" b3="214162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEVIE4" b2="230 KV" b3="239T2141" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32890</SeqNum>
    <Name>L230.Surry-Poolsville-Winchester.214</Name>
    <LastEdit Timestamp="2026-04-14T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="POOLSVIL" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POOLSVIL" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="21402-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="21402-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="SURRY4" b2="230 KV" b3="214A" />
      <ContingencyEquipment Action="L" Type="LN" b1="WINCHEST" b2="230 KV" b3="214B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINCHEST" b2="230 KV" b3="214T234" />
      <ContingencyEquipment Action="X" Type="XF" b1="WINCHEST" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WINCHEST" b2="35 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32900</SeqNum>
    <Name>L230.EPG-Woodbridge-PossumPoint.215</Name>
    <LastEdit Timestamp="2025-12-17T12:03:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EPG" b2="230 KV" b3="21552" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EPG" b2="230 KV" b3="H12T215" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="21592" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="G5T215" />
      <ContingencyEquipment Action="L" Type="LN" b1="WOODBRGE" b2="230 KV" b3="215B" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODBRGE" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODBRGE" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPG" b2="230 KV" b3="WOO-EPG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32910</SeqNum>
    <Name>L230.Elmont-Lakeside.216</Name>
    <LastEdit Timestamp="2024-05-14T10:09:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="21692" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMONT4" b2="230 KV" b3="216A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="216T2075" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELMONT4" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELMONT4" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="230 KV" b3="21622" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="230 KV" b3="216T2127" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32920</SeqNum>
    <Name>L230.Chesterfield-Varina-CharlesCtyRd-Lakeside.217</Name>
    <LastEdit Timestamp="2025-07-16T17:42:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLCTY" b2="230 KV" b3="217B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLCTY" b2="230 KV" b3="CHA-VARI" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHARLCTY" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHARLCTY" b2="34.5 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHARLCTY" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHARLCTY" b2="34.5 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="205T217" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="21712" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTER4" b2="230 KV" b3="CHE-VARI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="230 KV" b3="21722" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="230 KV" b3="H322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="230 KV" b3="H8T217" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKESID4" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAKESID4" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VARINA" b2="230 KV" b3="H132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VARINA" b2="35 KV" b3="LD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VARINA" b2="35 KV" b3="LD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="VARINA" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="VARINA" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32930</SeqNum>
    <Name>L230.Southwest-HullStreetRoad-Winterpock.219</Name>
    <LastEdit Timestamp="2025-10-02T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HULLSTR" b2="230 KV" b3="219C" />
      <ContingencyEquipment Action="L" Type="LN" b1="HULLSTR" b2="230 KV" b3="219X" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HULLSTR" b2="230 KV" b3="H282" />
      <ContingencyEquipment Action="X" Type="XF" b1="HULLSTR" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HULLSTR" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STHWEST" b2="230 KV" b3="21962" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERPK" b2="230 KV" b3="H14T219" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERPK" b2="230 KV" b3="H23T219" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32940</SeqNum>
    <Name>L230.Elmont-Northwest.221</Name>
    <LastEdit Timestamp="2024-05-14T10:10:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="22192" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMONT4" b2="230 KV" b3="221A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="L1T221" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELMONT4" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELMONT4" b2="35 KV" b3="TX4" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTNROAD" b2="230 KV" b3="221B" />
      <ContingencyEquipment Action="X" Type="XF" b1="MTNROAD" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTNROAD" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MTNROAD" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTNROAD" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWEST" b2="230 KV" b3="221T2127" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWEST" b2="230 KV" b3="221T222" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32950</SeqNum>
    <Name>L230.Southwest-RiverRoad-Northwest.222</Name>
    <LastEdit Timestamp="2026-04-13T15:02:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NWEST" b2="230 KV" b3="221T222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWEST" b2="230 KV" b3="22252" />
      <ContingencyEquipment Action="L" Type="LN" b1="NWEST" b2="230 KV" b3="222A" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NWEST" b2="230 KV" b3="SC8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWEST" b2="230 KV" b3="SC852" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIVERRD" b2="230 KV" b3="222B" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIVERRD" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERRD" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIVERRD" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERRD" b2="35 KV" b3="TX4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STHWEST" b2="230 KV" b3="22262" />
      <ContingencyEquipment Action="X" Type="XF" b1="STHWEST" b2="230 KV" b3="TX5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STHWEST" b2="35 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32960</SeqNum>
    <Name>L230.Lanexa-Dunnsville-NorthernNeck.224C</Name>
    <LastEdit Timestamp="2025-12-11T09:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DUNNSVIL" b2="230 KV" b3="DUN-KING" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNNSVIL" b2="230 KV" b3="H122CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNNSVIL" b2="230 KV" b3="H222CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="DUNNSVIL" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUNNSVIL" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DUNNSVIL" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUNNSVIL" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGQUEE" b2="230 KV" b3="H142" />
      <ContingencyEquipment Action="X" Type="XF" b1="KINGQUEE" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGQUEE" b2="36 KV" b3="TX1LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="230 KV" b3="22432" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="230 KV" b3="224T2113" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGQUEE" b2="230 KV" b3="KIN-LANE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="230 KV" b3="22452" />
      <ContingencyEquipment Action="L" Type="LN" b1="NRTHNECK" b2="230 KV" b3="224B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="230 KV" b3="H4T224" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32970</SeqNum>
    <Name>L230.Lakeview-Thelma.225</Name>
    <LastEdit Timestamp="2025-11-03T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEVIE4" b2="230 KV" b3="22562" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEVIE4" b2="230 KV" b3="225T239" />
      <ContingencyEquipment Action="L" Type="LN" b1="THELMA4" b2="230 KV" b3="225A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA4" b2="230 KV" b3="225T2244" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA4" b2="230 KV" b3="225T232" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32980</SeqNum>
    <Name>L230.Churchland-Harborview-Crittenden-Surry.226</Name>
    <LastEdit Timestamp="2026-04-13T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRCHLND" b2="230 KV" b3="22652" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHRCHLND" b2="230 KV" b3="226C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRCHLND" b2="230 KV" b3="226T2099" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRITTNDN" b2="230 KV" b3="226_B" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRITTNDN" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRITTNDN" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBORVW" b2="230 KV" b3="H222" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HARBORVW" b2="35 KV" b3="T124" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARBORVW" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="212T226" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="22602" />
      <ContingencyEquipment Action="L" Type="LN" b1="SURRY4" b2="230 KV" b3="226A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>32990</SeqNum>
    <Name>L230.Chesterfield-Hopewell.228</Name>
    <LastEdit Timestamp="2025-11-13T10:40:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="22812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="228T2326" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="22832" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPEWEL4" b2="230 KV" b3="228A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="228T268" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33000</SeqNum>
    <Name>L230.Chinquapin-Everetts.2160</Name>
    <LastEdit Timestamp="2026-04-13T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHINQUPN" b2="230 KV" b3="21602177" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHINQUPN" b2="230 KV" b3="2160B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHINQUPN" b2="230 KV" b3="H1T2160" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERETTS" b2="230 KV" b3="218T2160" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERETTS" b2="230 KV" b3="H4T2160" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33010</SeqNum>
    <Name>L230.Thelma-Gaston.232</Name>
    <LastEdit Timestamp="2026-04-14T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GASTON4" b2="230 KV" b3="232A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GASTON4" b2="14 KV" b3="G1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GASTON4" b2="14 KV" b3="G2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GASTON4" b2="14 KV" b3="G3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GASTON4" b2="14 KV" b3="G4" />
      <ContingencyEquipment Action="X" Type="XF" b1="GASTON4" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GASTON4" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA4" b2="230 KV" b3="213T232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA4" b2="230 KV" b3="225T232" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33020</SeqNum>
    <Name>L230.Dooms-Charlottesville.233</Name>
    <LastEdit Timestamp="2026-04-13T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BARRCKRD" b2="230 KV" b3="233B1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BARRCKRD" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BARRCKRD" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLTSV" b2="230 KV" b3="233A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLTSV" b2="230 KV" b3="233T2028" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLTSV" b2="230 KV" b3="233T291" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROZET" b2="230 KV" b3="233B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROZET" b2="230 KV" b3="233C" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROZET" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CROZET" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="23342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="233T2156" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HYDROAD" b2="230 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33030</SeqNum>
    <Name>L230.Whealton-Winchester.234</Name>
    <LastEdit Timestamp="2025-10-20T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="WHEALTON" b2="230 KV" b3="234A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEALTON" b2="230 KV" b3="234T2138" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEALTON" b2="230 KV" b3="H2T234" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINCHEST" b2="230 KV" b3="214T234" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINCHEST" b2="230 KV" b3="H362" />
      <ContingencyEquipment Action="X" Type="XF" b1="WINCHEST" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WINCHEST" b2="35 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33040</SeqNum>
    <Name>L230.Clover-Easters.2226</Name>
    <LastEdit Timestamp="2024-05-17T11:34:08" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="222612" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="SX122226" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="222632" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVER" b2="230 KV" b3="CLV-EAST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="WT2226" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33050</SeqNum>
    <Name>L230.Southwest-Plaza.236</Name>
    <LastEdit Timestamp="2026-04-13T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PLAZA" b2="230 KV" b3="236A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLAZA" b2="115 KV" b3="L422" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLAZA" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLAZA" b2="230 KV" b3="TX5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLAZA" b2="35 KV" b3="TX5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STHWEST" b2="230 KV" b3="23662" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33060</SeqNum>
    <Name>L230.Braddock-KeeneMill-Lakeridge-PossumPoint.237</Name>
    <LastEdit Timestamp="2026-04-10T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRADDOCK" b2="230 KV" b3="237A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADDOCK" b2="230 KV" b3="237T294" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADDOCK" b2="230 KV" b3="237T297" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEENMILL" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEENMILL" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKRIDGE" b2="230 KV" b3="237B" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKRIDGE" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAKRIDGE" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="23792" />
      <ContingencyEquipment Action="L" Type="LN" b1="POSSUMP4" b2="230 KV" b3="237C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="H9T237" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33070</SeqNum>
    <Name>L230.Lakeview-Hornertown-Rosemary.239</Name>
    <LastEdit Timestamp="2026-04-13T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HORNERTN" b2="230 KV" b3="2057A" />
      <ContingencyEquipment Action="L" Type="LN" b1="HORNERTN" b2="230 KV" b3="239A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORNERTN" b2="230 KV" b3="239T2056" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORNERTN" b2="230 KV" b3="239T2057" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEVIE4" b2="230 KV" b3="225T239" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEVIE4" b2="230 KV" b3="239T2141" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSEMARY" b2="230 KV" b3="205702" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROSEMARY" b2="13.8 KV" b3="NUG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33090</SeqNum>
    <Name>L230.Hayfield-VirginiaHills-JeffersonStreet.241</Name>
    <LastEdit Timestamp="2025-11-13T09:42:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYFIEL4" b2="230 KV" b3="210T241" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAYFIEL4" b2="230 KV" b3="241A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYFIEL4" b2="230 KV" b3="241T2264" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFRSON" b2="230 KV" b3="24122" />
      <ContingencyEquipment Action="L" Type="LN" b1="JEFFRSON" b2="230 KV" b3="241B" />
      <ContingencyEquipment Action="X" Type="XF" b1="VAHILLS" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VAHILLS" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="VAHILLS" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VAHILLS" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33100</SeqNum>
    <Name>L230.Ox-Franconia-Vandorn.243</Name>
    <LastEdit Timestamp="2026-04-13T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FRANCONA" b2="230 KV" b3="243A" />
      <ContingencyEquipment Action="X" Type="XF" b1="FRANCONA" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRANCONA" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="24342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="243T2097" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VANDORN" b2="230 KV" b3="210T243" />
      <ContingencyEquipment Action="L" Type="LN" b1="VANDORN" b2="230 KV" b3="243B" />
      <ContingencyEquipment Action="X" Type="XF" b1="VANDORN" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VANDORN" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33120</SeqNum>
    <Name>L230.Greenwich-Greenrun.245</Name>
    <LastEdit Timestamp="2025-08-26T17:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENRUN" b2="230 KV" b3="245T2025" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENRUN" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENRUN" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="230 KV" b3="24552" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENWCH" b2="230 KV" b3="245A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="230 KV" b3="245T2019" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33130</SeqNum>
    <Name>L230.Ox-VirginiaHills.248B + SR1</Name>
    <LastEdit Timestamp="2025-04-24T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="24842" />
      <ContingencyEquipment Action="L" Type="LN" b1="OX4" b2="230 KV" b3="248B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="248T2013" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VAHILLS" b2="230 KV" b3="DB24832" />
      <ContingencyEquipment Action="U" Type="GEN" b1="VAHILLS" b2="230 KV" b3="SR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VAHILLS" b2="230 KV" b3="SR132" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33140</SeqNum>
    <Name>L230.Carson-Locks.249</Name>
    <LastEdit Timestamp="2024-12-09T15:17:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="230 KV" b3="24972-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="230 KV" b3="24972-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAPRLTP" b2="230 KV" b3="249B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAPRLTP" b2="230 KV" b3="249C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHAPARAL" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKS" b2="230 KV" b3="205T249" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOCKS" b2="230 KV" b3="249A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKS" b2="230 KV" b3="H322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKS" b2="230 KV" b3="H7T249" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33150</SeqNum>
    <Name>L230.Arlington-Glebe.250</Name>
    <LastEdit Timestamp="2025-01-28T11:05:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARLINGTN" b2="230 KV" b3="250A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARLINGTN" b2="230 KV" b3="250T2115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARLINGTN" b2="230 KV" b3="250T258" />
      <ContingencyEquipment Action="X" Type="XF" b1="ARLINGTN" b2="230 KV" b3="TX5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ARLINGTN" b2="35 KV" b3="TX5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLEBE" b2="230 KV" b3="250T2023" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLEBE" b2="230 KV" b3="250T276" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLEBE" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLEBE" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33160</SeqNum>
    <Name>L230.GlenCarlyn-FallsChurch-Idylwood.251</Name>
    <LastEdit Timestamp="2026-01-07T09:27:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FLSCHURC" b2="230 KV" b3="251B" />
      <ContingencyEquipment Action="L" Type="LN" b1="IDYLWOO4" b2="230 KV" b3="251C" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLSCHURC" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLSCHURC" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCARLYN" b2="230 KV" b3="251T266" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCARLYN" b2="230 KV" b3="251T277" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLCARLYN" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IDYLWOO4" b2="230 KV" b3="25112X" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33170</SeqNum>
    <Name>L230.Valley-Harrisonburg.253</Name>
    <LastEdit Timestamp="2026-04-14T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HARRSNBG" b2="230 KV" b3="253" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="230 KV" b3="25392" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="230 KV" b3="253T2017" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEY4" b2="230 KV" b3="25312-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEY4" b2="230 KV" b3="25312-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33210</SeqNum>
    <Name>L230.Chrchlnd-CranyIsl-TannerPt-NIT-SewellPt.257</Name>
    <LastEdit Timestamp="2024-10-29T16:27:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRCHLND" b2="230 KV" b3="25752" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRCHLND" b2="230 KV" b3="257T267" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRANYISL" b2="230 KV" b3="257A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRANYISL" b2="230 KV" b3="257C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NIT" b2="230 KV" b3="H122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NIT" b2="230 KV" b3="H222" />
      <ContingencyEquipment Action="L" Type="LN" b1="NIT" b2="230 KV" b3="NIT-TANN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="230 KV" b3="257T2082" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="230 KV" b3="257T2093" />
      <ContingencyEquipment Action="L" Type="LN" b1="NIT" b2="230 KV" b3="NIT-SEWE" />
      <ContingencyEquipment Action="L" Type="LN" b1="TANNERPT" b2="230 KV" b3="257B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33220</SeqNum>
    <Name>L230.Arlington-Glebe.258</Name>
    <LastEdit Timestamp="2025-11-26T08:57:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARLINGTN" b2="230 KV" b3="250T258" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARLINGTN" b2="230 KV" b3="258A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARLINGTN" b2="230 KV" b3="258T273" />
      <ContingencyEquipment Action="X" Type="XF" b1="ARLINGTN" b2="230 KV" b3="TX6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ARLINGTN" b2="35 KV" b3="TX6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLEBE" b2="230 KV" b3="25892" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLEBE" b2="230 KV" b3="258T2036" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33230</SeqNum>
    <Name>L230.Chesterfield-Basin.259</Name>
    <LastEdit Timestamp="2026-04-13T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASIN" b2="230 KV" b3="25942" />
      <ContingencyEquipment Action="L" Type="LN" b1="BASIN" b2="230 KV" b3="259A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="25912" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="259T2003" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33240</SeqNum>
    <Name>L230.Grottoes-Harrisonburg.260</Name>
    <LastEdit Timestamp="2026-04-13T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GROTTOES" b2="230 KV" b3="260T272" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="230 KV" b3="26092CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRSNBG" b2="230 KV" b3="260A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="230 KV" b3="XT260" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33250</SeqNum>
    <Name>L230.Shellbank-NewportNews.261</Name>
    <LastEdit Timestamp="2026-04-13T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="NWPORTNW" b2="230 KV" b3="261A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWPORTNW" b2="230 KV" b3="H8T261" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NWPORTNW" b2="230 KV" b3="SC7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELLBNK" b2="230 KV" b3="26152" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33260</SeqNum>
    <Name>230/115.Chesapeake.TX3</Name>
    <LastEdit Timestamp="2024-12-18T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="230 KV" b3="H322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="115 KV" b3="L322" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESAPKE" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33270</SeqNum>
    <Name>L230.Chuckatuck-NewportNews.263 (Sctnlz F)</Name>
    <LastEdit Timestamp="2025-01-27T15:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHUCKATK" b2="230 KV" b3="263A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHUCKATK" b2="230 KV" b3="263T289" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHUCKATK" b2="230 KV" b3="263T290" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENNSCH" b2="230 KV" b3="BEN-COPE" />
      <ContingencyEquipment Action="X" Type="XF" b1="COPELDPK" b2="230 KV" b3="TX1A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COPELDPK" b2="34.5 KV" b3="TX1A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COPELDPK" b2="22 KV" b3="TX2 LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="COPELDPK" b2="230 KV" b3="XF2" />
      <ContingencyEquipment Action="L" Type="LN" b1="COPELDPK" b2="230 KV" b3="263C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWPORTNW" b2="230 KV" b3="H8T263" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NWPORTNW" b2="22 KV" b3="TX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="NWPORTNW" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33280</SeqNum>
    <Name>L230.Hunter-Reston.264</Name>
    <LastEdit Timestamp="2026-04-13T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTER" b2="230 KV" b3="264T2005" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUNTER" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUNTER" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="RESTON" b2="230 KV" b3="264A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RESTON" b2="230 KV" b3="264T2010" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RESTON" b2="230 KV" b3="264T2015" />
      <ContingencyEquipment Action="X" Type="XF" b1="RESTON" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RESTON" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33300</SeqNum>
    <Name>L230.Fentress-Shawboro.269</Name>
    <LastEdit Timestamp="2026-04-13T14:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="26922" />
      <ContingencyEquipment Action="L" Type="LN" b1="FENTRES4" b2="230 KV" b3="269B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="269T2128" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWBORO" b2="230 KV" b3="269T2064" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWBORO" b2="230 KV" b3="269T2136" />
      <ContingencyEquipment Action="L" Type="LN" b1="SLIGO" b2="230 KV" b3="269A" />
      <ContingencyEquipment Action="X" Type="XF" b1="SLIGO" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SLIGO" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33310</SeqNum>
    <Name>L230.Burke-Ravensworth.270</Name>
    <LastEdit Timestamp="2026-04-13T14:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURKE" b2="230 KV" b3="244T270" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURKE" b2="230 KV" b3="270A" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURKE" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BURKE" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAVNSWTH" b2="230 KV" b3="270T2022" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAVNSWTH" b2="230 KV" b3="270T281" />
      <ContingencyEquipment Action="L" Type="LN" b1="SIDEBURN" b2="230 KV" b3="270B" />
      <ContingencyEquipment Action="X" Type="XF" b1="SIDEBURN" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SIDEBURN" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33320</SeqNum>
    <Name>L230.Fentress-Pocaty.2240</Name>
    <LastEdit Timestamp="2025-07-11T13:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="224022-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="224022-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCATY" b2="230 KV" b3="224042" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCATY" b2="230 KV" b3="271T2240" />
      <ContingencyEquipment Action="L" Type="LN" b1="FENTRES4" b2="230 KV" b3="FEN-POTY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33340</SeqNum>
    <Name>L230.Arlington-GlenCarlyn.273</Name>
    <LastEdit Timestamp="2025-01-28T11:06:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARLINGTN" b2="230 KV" b3="258T273" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARLINGTN" b2="230 KV" b3="273A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARLINGTN" b2="230 KV" b3="273T2115" />
      <ContingencyEquipment Action="X" Type="XF" b1="ARLINGTN" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ARLINGTN" b2="35 KV" b3="TX4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCARLYN" b2="230 KV" b3="273T2115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCARLYN" b2="230 KV" b3="273T277" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLCARLYN" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLCARLYN" b2="35 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33360</SeqNum>
    <Name>L230.Braddock-Ravensworth.281</Name>
    <LastEdit Timestamp="2026-04-13T14:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADDOCK" b2="230 KV" b3="207T281" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADDOCK" b2="230 KV" b3="281A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADDOCK" b2="230 KV" b3="281T297" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAVNSWTH" b2="230 KV" b3="270T281" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAVNSWTH" b2="230 KV" b3="281T2022" />
      <ContingencyEquipment Action="X" Type="XF" b1="RAVNSWTH" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RAVNSWTH" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33370</SeqNum>
    <Name>L230.Midlothian-HullStreet-IronBridge-Spruance.282</Name>
    <LastEdit Timestamp="2026-02-11T06:34:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HULLSTR" b2="230 KV" b3="282C" />
      <ContingencyEquipment Action="X" Type="XF" b1="HULLSTR" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HULLSTR" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HULLSTR" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HULLSTR" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="L" Type="LN" b1="IRONBRI4" b2="230 KV" b3="282B" />
      <ContingencyEquipment Action="X" Type="XF" b1="IRONBRI4" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IRONBRI4" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLOTH" b2="230 KV" b3="28212" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MIDLOTH" b2="35 KV" b3="DRYBRIBS" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDLOTH" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDLOTH" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDLOTH" b2="230 KV" b3="TX5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDLOTH" b2="35 KV" b3="TX5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLOTH" b2="230 KV" b3="WT282" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPRUANCE" b2="230 KV" b3="282A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRUANCE" b2="230 KV" b3="282T2065" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRUANCE" b2="230 KV" b3="AUX1LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRUANCE" b2="230 KV" b3="AUX2LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRUANCE" b2="230 KV" b3="G12T282" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33380</SeqNum>
    <Name>L230.Elmont-Northeast.283</Name>
    <LastEdit Timestamp="2026-04-13T14:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="28392-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="28392-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMONT4" b2="230 KV" b3="283A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="230 KV" b3="28362-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="230 KV" b3="28362-12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33390</SeqNum>
    <Name>L230.Basin-Northeast.284</Name>
    <LastEdit Timestamp="2026-04-13T14:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASIN" b2="230 KV" b3="28442" />
      <ContingencyEquipment Action="L" Type="LN" b1="BASIN" b2="230 KV" b3="284A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="230 KV" b3="28462CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="230 KV" b3="H9T284" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33410</SeqNum>
    <Name>L230.Chickahomny-Lightfoot-Waller.2102</Name>
    <LastEdit Timestamp="2024-12-10T16:07:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="210222-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="210222-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="LGHTFOOT" b2="230 KV" b3="2102A" />
      <ContingencyEquipment Action="L" Type="LN" b1="WALLER" b2="230 KV" b3="2102B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LGHTFOOT" b2="230 KV" b3="H212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LGHTFOOT" b2="230 KV" b3="H312" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LGHTFOOT" b2="35 KV" b3="ROCHAMSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="LGHTFOOT" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LGHTFOOT" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="LGHTFOOT" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LGHTFOOT" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALLER" b2="230 KV" b3="21022146" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33420</SeqNum>
    <Name>L230.Darbytown-Turner-Elko-TechPark.286</Name>
    <LastEdit Timestamp="2026-04-24T08:41:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARBYTWN" b2="230 KV" b3="G12T286" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARBYTWN" b2="230 KV" b3="G34T286" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKO4" b2="230 KV" b3="286B1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ELKO4" b2="35 KV" b3="BRIELFSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELKO4" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELKO4" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TECHPARK" b2="230 KV" b3="28612" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TECHPARK" b2="230 KV" b3="286T2344" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKO4" b2="230 KV" b3="ELK-TECH" />
      <ContingencyEquipment Action="L" Type="LN" b1="TURNER4" b2="230 KV" b3="286A" />
      <ContingencyEquipment Action="X" Type="XF" b1="TURNER4" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TURNER4" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33430</SeqNum>
    <Name>L230.Chesterfield-Chickahomny.287</Name>
    <LastEdit Timestamp="2026-04-13T15:06:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="208T287" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="28712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="28722" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICKHOM" b2="230 KV" b3="287A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="287T2129" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33450</SeqNum>
    <Name>L230.Chuckatuck-Surry.290</Name>
    <LastEdit Timestamp="2026-04-13T15:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHUCKATK" b2="230 KV" b3="263T290" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHUCKATK" b2="230 KV" b3="289T290" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="29002" />
      <ContingencyEquipment Action="L" Type="LN" b1="SURRY4" b2="230 KV" b3="290A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="290T2047" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33460</SeqNum>
    <Name>L230.Charlottesville-BarracksRd-Crozet-Dooms.291</Name>
    <LastEdit Timestamp="2026-04-14T09:30:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BARRCKRD" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BARRCKRD" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLTSV" b2="230 KV" b3="233T291" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLTSV" b2="230 KV" b3="291C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLTSV" b2="230 KV" b3="291T2054" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHARLTSV" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHARLTSV" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROZET" b2="230 KV" b3="291A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROZET" b2="230 KV" b3="291B" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROZET" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CROZET" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="272T291" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="29142" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33470</SeqNum>
    <Name>L230.Whealton-RockLanding-Yorktown.292</Name>
    <LastEdit Timestamp="2024-11-20T13:03:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKLNDG" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKLNDG" b2="230 KV" b3="H152" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKLNDG" b2="34.5 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKLNDG" b2="230 KV" b3="ROC-WHEA" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKLNDG" b2="230 KV" b3="ROC-YORK" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ROCKLNDG" b2="230 KV" b3="SC3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKLNDG" b2="230 KV" b3="SC352" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEALTON" b2="230 KV" b3="29242" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEALTON" b2="230 KV" b3="H2T292" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="230 KV" b3="29282" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="230 KV" b3="XT292" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33480</SeqNum>
    <Name>L230.Staunton-WStaunton-Valley.293</Name>
    <LastEdit Timestamp="2025-06-05T12:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STAUNTON" b2="230 KV" b3="293T2156" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAUNTON" b2="230 KV" b3="H672" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEY4" b2="230 KV" b3="29312-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEY4" b2="230 KV" b3="29312-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="STAUNTON" b2="230 KV" b3="293" />
      <ContingencyEquipment Action="L" Type="LN" b1="WSTAUNTN" b2="230 KV" b3="293B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WSTAUNTN" b2="23 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WSTAUNTN" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WSTAUNTN" b2="23 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="WSTAUNTN" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33520</SeqNum>
    <Name>L500.Surry-Suffolk.531</Name>
    <LastEdit Timestamp="2026-04-14T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SUFFOLK" b2="500 KV" b3="531A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="500 KV" b3="531T565" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="500 KV" b3="H8T531" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="500 KV" b3="53102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="500 KV" b3="531T582" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33540</SeqNum>
    <Name>L500.Dooms-Cunningham.534</Name>
    <LastEdit Timestamp="2024-09-19T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUNNIHAM" b2="500 KV" b3="534T542" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUNNIHAM" b2="500 KV" b3="534T564" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOOMS4" b2="500 KV" b3="534A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="500 KV" b3="534T549" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="500 KV" b3="H7T534" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33550</SeqNum>
    <Name>L500.Cunningham-Fluvanna.542</Name>
    <LastEdit Timestamp="2026-04-14T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUNNIHAM" b2="500 KV" b3="534T542" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUNNIHAM" b2="500 KV" b3="542T553" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLUVANNA" b2="500 KV" b3="542A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FLUVANNA" b2="18 KV" b3="GT22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLUVANNA" b2="500 KV" b3="GT22" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FLUVANNA" b2="18 KV" b3="GT32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLUVANNA" b2="500 KV" b3="GT32" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLUVANNA" b2="500 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLUVANNA" b2="500 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33570</SeqNum>
    <Name>L500.Dooms-Valley.549</Name>
    <LastEdit Timestamp="2026-04-14T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="500 KV" b3="534T549" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="500 KV" b3="H9T549" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEY4" b2="500 KV" b3="548T549" />
      <ContingencyEquipment Action="L" Type="LN" b1="VALLEY4" b2="500 KV" b3="549A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEY4" b2="500 KV" b3="H2T549" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33580</SeqNum>
    <Name>L500.MtStorm-Valley.550</Name>
    <LastEdit Timestamp="2026-01-27T10:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MTSTORM4" b2="500 KV" b3="550A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="550TB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="550TB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEY4" b2="500 KV" b3="H1T550" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEY4" b2="500 KV" b3="H2T550" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33590</SeqNum>
    <Name>L500.Bristers-Chancelr.552</Name>
    <LastEdit Timestamp="2025-01-28T12:34:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRISTERS" b2="500 KV" b3="545T552" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRISTERS" b2="500 KV" b3="552" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRISTERS" b2="500 KV" b3="55262" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHANCELR" b2="500 KV" b3="55292" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHANCELR" b2="500 KV" b3="H1T552" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33600</SeqNum>
    <Name>L500.Elmont-Cunningham.553</Name>
    <LastEdit Timestamp="2026-04-30T11:31:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUNNIHAM" b2="500 KV" b3="542T553" />
      <ContingencyEquipment Action="L" Type="LN" b1="CUNNIHAM" b2="500 KV" b3="553A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUNNIHAM" b2="500 KV" b3="553T564" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="500 KV" b3="553T574" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="500 KV" b3="H2T553" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33610</SeqNum>
    <Name>L500.Dooms-Lexington.555</Name>
    <LastEdit Timestamp="2026-04-14T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="500 KV" b3="H7T555" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="500 KV" b3="H9T555" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="500 KV" b3="55502" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEXINGTN" b2="500 KV" b3="555A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="500 KV" b3="XT555" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33620</SeqNum>
    <Name>L500.Chickahominy-Elmont.557A</Name>
    <LastEdit Timestamp="2026-04-30T11:39:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="500 KV" b3="55722" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICKHOM" b2="500 KV" b3="557A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="500 KV" b3="557T567" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="500 KV" b3="H1T557" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="500 KV" b3="H2T557" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33640</SeqNum>
    <Name>L500.Clifton-Ox.561+500/230.Clifton.TX2</Name>
    <LastEdit Timestamp="2025-06-03T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLIFTON" b2="500 KV" b3="561A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTON" b2="500 KV" b3="H1T561" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTON" b2="230 KV" b3="L282" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLIFTON" b2="500 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="500 KV" b3="56142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="500 KV" b3="561T571" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33650</SeqNum>
    <Name>L500.Carson-Septa.562</Name>
    <LastEdit Timestamp="2025-10-16T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="500 KV" b3="56272" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARSON4" b2="500 KV" b3="562A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="500 KV" b3="562T563" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEPTA4" b2="500 KV" b3="562T578" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEPTA4" b2="500 KV" b3="562T579" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33660</SeqNum>
    <Name>L500.Carson-Midlothian.563</Name>
    <LastEdit Timestamp="2026-04-14T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="500 KV" b3="562T563" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="500 KV" b3="56372" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARSON4" b2="500 KV" b3="563A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLOTH" b2="500 KV" b3="563T576" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLOTH" b2="500 KV" b3="H6T563" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33670</SeqNum>
    <Name>L500.Cunningham-Fluvanna.564</Name>
    <LastEdit Timestamp="2026-04-14T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUNNIHAM" b2="500 KV" b3="534T564" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUNNIHAM" b2="500 KV" b3="553T564" />
      <ContingencyEquipment Action="L" Type="LN" b1="CUNNIHAM" b2="500 KV" b3="564A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FLUVANNA" b2="18 KV" b3="GS12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLUVANNA" b2="500 KV" b3="GS12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FLUVANNA" b2="18 KV" b3="GT12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLUVANNA" b2="500 KV" b3="GT12" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLUVANNA" b2="500 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLUVANNA" b2="500 KV" b3="TXS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33680</SeqNum>
    <Name>L500.Chickahominy-Surry.567</Name>
    <LastEdit Timestamp="2026-01-27T10:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="500 KV" b3="557T567" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="500 KV" b3="56722" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="500 KV" b3="56702" />
      <ContingencyEquipment Action="L" Type="LN" b1="SURRY4" b2="500 KV" b3="567A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="500 KV" b3="G2T567" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33690</SeqNum>
    <Name>L500.Ladysmith-Possum Point.568</Name>
    <LastEdit Timestamp="2025-08-22T07:47:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LADYSMTH" b2="500 KV" b3="568A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMTH" b2="500 KV" b3="568T581" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMTH" b2="500 KV" b3="H2T568" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="500 KV" b3="568T571" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="500 KV" b3="H1T568" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33700</SeqNum>
    <Name>L500.Loudoun-Morrisville.569</Name>
    <LastEdit Timestamp="2026-04-14T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="500 KV" b3="569T584" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="500 KV" b3="H1T569" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="500 KV" b3="541T569" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORRISVL" b2="500 KV" b3="569A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="500 KV" b3="H2T569" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33720</SeqNum>
    <Name>L500.PossumPoint-Ox.571</Name>
    <LastEdit Timestamp="2026-04-14T09:32:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="500 KV" b3="561T571" />
      <ContingencyEquipment Action="L" Type="LN" b1="OX4" b2="500 KV" b3="571A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="500 KV" b3="H2T571" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="500 KV" b3="560T571" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="500 KV" b3="568T571" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33730</SeqNum>
    <Name>L500.Morrisville-Spotsylvania.594</Name>
    <LastEdit Timestamp="2025-01-24T09:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="500 KV" b3="545T594" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="500 KV" b3="H1T594" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="500 KV" b3="515T594" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORRISVL" b2="500 KV" b3="594A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="500 KV" b3="H1T594" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33740</SeqNum>
    <Name>L500.Elmont-Ladysmith.574</Name>
    <LastEdit Timestamp="2026-04-30T11:40:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="500 KV" b3="553T574" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="500 KV" b3="H1T574" />
      <ContingencyEquipment Action="L" Type="LN" b1="LADYSMTH" b2="500 KV" b3="574A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMTH" b2="500 KV" b3="574T575" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMTH" b2="500 KV" b3="H2T574" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33750</SeqNum>
    <Name>L500.Ladysmith-NorthAnna.575</Name>
    <LastEdit Timestamp="2025-06-10T08:04:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMTH" b2="500 KV" b3="574T575" />
      <ContingencyEquipment Action="L" Type="LN" b1="LADYSMTH" b2="500 KV" b3="575A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMTH" b2="500 KV" b3="H1T575" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="500 KV" b3="57502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="500 KV" b3="G2T575" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33770</SeqNum>
    <Name>L500.Septa-Surry.578</Name>
    <LastEdit Timestamp="2025-10-17T12:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEPTA4" b2="500 KV" b3="562T578" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEPTA4" b2="500 KV" b3="578A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEPTA4" b2="500 KV" b3="578T586" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="500 KV" b3="57802" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="500 KV" b3="WT578" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33780</SeqNum>
    <Name>L500.Yadkin-Septa.579A1</Name>
    <LastEdit Timestamp="2025-10-17T12:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEPTA4" b2="500 KV" b3="562T579" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEPTA4" b2="500 KV" b3="579A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEPTA4" b2="500 KV" b3="579T586" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="500 KV" b3="H1T579" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="500 KV" b3="H5T579" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33870</SeqNum>
    <Name>230/115.Lexington.TX2</Name>
    <LastEdit Timestamp="2025-01-23T18:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="230 KV" b3="H202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="115 KV" b3="L2T10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="115 KV" b3="L2T194" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEXINGTN" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33880</SeqNum>
    <Name>230/115.Lexington.TX4</Name>
    <LastEdit Timestamp="2025-01-23T18:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="230 KV" b3="H402" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="115 KV" b3="L4T26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="115 KV" b3="L4T9" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEXINGTN" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33890</SeqNum>
    <Name>L115.Craigsville-Lexington.10</Name>
    <LastEdit Timestamp="2026-04-16T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRAIGSVL" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOSHEN4" b2="115 KV" b3="10A" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOSHEN4" b2="115 KV" b3="10B" />
      <ContingencyEquipment Action="X" Type="XF" b1="GOSHEN4" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOSHEN4" b2="46 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GOSHEN4" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOSHEN4" b2="22 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="115 KV" b3="10T26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="115 KV" b3="L2T10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33900</SeqNum>
    <Name>L115.Gordonsv-Somerset-DbleDay-Orange-Oakgreen.11</Name>
    <LastEdit Timestamp="2025-04-24T14:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBLEDP" b2="115 KV" b3="11B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOUBLEDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONSV" b2="115 KV" b3="1182" />
      <ContingencyEquipment Action="L" Type="LN" b1="GORDONSV" b2="115 KV" b3="11A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGREEN" b2="115 KV" b3="11T153" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGREEN" b2="115 KV" b3="2T11" />
      <ContingencyEquipment Action="L" Type="LN" b1="ORANGE" b2="115 KV" b3="11C" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKGREEN" b2="115 KV" b3="11D" />
      <ContingencyEquipment Action="X" Type="XF" b1="ORANGE" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ORANGE" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ORANGE" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ORANGE" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ORANGE" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ORANGE" b2="13 KV" b3="TX3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SOMERSET" b2="115 KV" b3="SC3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOMERSET" b2="35 KV" b3="SOME_AP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOMERSET" b2="35 KV" b3="SOME_DVP" />
      <ContingencyEquipment Action="X" Type="XF" b1="SOMERSET" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33910</SeqNum>
    <Name>L115.Poe-Disputania-Waverly-Wakefield-BellAve.15</Name>
    <LastEdit Timestamp="2024-07-16T12:29:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELLAVE" b2="115 KV" b3="105795" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLAVE" b2="115 KV" b3="15E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLAVE" b2="115 KV" b3="15T44" />
      <ContingencyEquipment Action="L" Type="LN" b1="DISPUTNT" b2="115 KV" b3="15B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DISPUTNT" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POE" b2="115 KV" b3="1552" />
      <ContingencyEquipment Action="L" Type="LN" b1="POE" b2="115 KV" b3="15A" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAKFIELD" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAKFIELD" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAKFIELD" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAKFIELD" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAVERLY4" b2="115 KV" b3="15D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY4" b2="115 KV" b3="H202" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAVERLY4" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAVERLY4" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAVERLY4" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAVERLY4" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAVLYNO2" b2="115 KV" b3="15C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAVLYNO2" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33920</SeqNum>
    <Name>L115.Chesterfield-Northeast.17</Name>
    <LastEdit Timestamp="2026-04-16T13:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="115 KV" b3="1712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="115 KV" b3="1762-9" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTER4" b2="115 KV" b3="17A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="115 KV" b3="L7T17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33950</SeqNum>
    <Name>L115.Everetts-PoplarChapel-Trowbridge.25</Name>
    <LastEdit Timestamp="2026-04-16T13:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERETTS" b2="115 KV" b3="2512" />
      <ContingencyEquipment Action="L" Type="LN" b1="EVERETTS" b2="115 KV" b3="25A" />
      <ContingencyEquipment Action="L" Type="LN" b1="PCHAPEL" b2="115 KV" b3="25B" />
      <ContingencyEquipment Action="X" Type="XF" b1="PCHAPEL" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PCHAPEL" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="115 KV" b3="25T168" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33960</SeqNum>
    <Name>L115.BalconyFalls-BuenaVista-Rockbrdg-Lexington.26</Name>
    <LastEdit Timestamp="2025-05-29T14:33:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BALCFALL" b2="115 KV" b3="2612CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALCFALL" b2="115 KV" b3="26T141CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUENAVST" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUENAVST" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUENAVST" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUENAVST" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="JAMESLEE" b2="115 KV" b3="26A" />
      <ContingencyEquipment Action="L" Type="LN" b1="JAMESLEE" b2="115 KV" b3="26B" />
      <ContingencyEquipment Action="S" Type="SD" b1="JAMESLEE" b2="115 KV" b3="26B1SD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JAMESLEE" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="115 KV" b3="10T26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="115 KV" b3="L4T26" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKBRDG" b2="115 KV" b3="26C" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKBRDG" b2="115 KV" b3="26D" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKBRDG" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKBRDG" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKBRDG" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKBRDG" b2="13 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33970</SeqNum>
    <Name>L115.Greenwich-DavisCorner-Burton.166</Name>
    <LastEdit Timestamp="2026-04-16T13:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BURTON" b2="115 KV" b3="166B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTON" b2="115 KV" b3="27T166" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTON" b2="115 KV" b3="67T166" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTON" b2="115 KV" b3="H212" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BURTON" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAVISCNR" b2="115 KV" b3="166A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISCNR" b2="115 KV" b3="H382" />
      <ContingencyEquipment Action="X" Type="XF" b1="DAVISCNR" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAVISCNR" b2="13 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="115 KV" b3="135T166" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="115 KV" b3="L1T166" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>33980</SeqNum>
    <Name>L115.Fredrksbg-TriangleTap-PossumPoint-Quantico.29</Name>
    <LastEdit Timestamp="2025-06-24T13:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRDRKSBG" b2="115 KV" b3="2942" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="115 KV" b3="2992" />
      <ContingencyEquipment Action="L" Type="LN" b1="POSSUMP4" b2="115 KV" b3="29C" />
      <ContingencyEquipment Action="L" Type="LN" b1="QUANTICO" b2="115 KV" b3="29BC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="QUANTICO" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="QUANTICO" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRDRKSBG" b2="115 KV" b3="FRE-TRIA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34000</SeqNum>
    <Name>L115.Remington-BrandyDP-MtnRun-Culpeper.70</Name>
    <LastEdit Timestamp="2026-04-16T13:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRANDYDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRANDYDP" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CULPEPER" b2="115 KV" b3="70D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CULPEPER" b2="115 KV" b3="H152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CULPEPER" b2="115 KV" b3="H252" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CULPEPER" b2="115 KV" b3="SC3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CULPEPER" b2="115 KV" b3="SC352" />
      <ContingencyEquipment Action="X" Type="XF" b1="CULPEPER" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CULPEPER" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CULPEPER" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CULPEPER" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CULPERDP" b2="115 KV" b3="TX1LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CULPERDP" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTN RUN" b2="115 KV" b3="2T70" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDYDP" b2="115 KV" b3="70B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CULPERDP" b2="115 KV" b3="70C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTN RUN" b2="115 KV" b3="RECLOAD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGTN" b2="115 KV" b3="7042" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDYDP" b2="115 KV" b3="70A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34010</SeqNum>
    <Name>L115.Altavista-Dominion-Bellevue-Skimmer.30</Name>
    <LastEdit Timestamp="2025-06-12T13:09:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAVSTA" b2="115 KV" b3="3032" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALTAVSTA" b2="115 KV" b3="30A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLEVU4" b2="115 KV" b3="30B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLEVU4" b2="115 KV" b3="30C1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELLEVU4" b2="34.5 KV" b3="LOAD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLEVU4" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOMINION" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOMINION" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKIMMER4" b2="115 KV" b3="3062" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34040</SeqNum>
    <Name>L115.SkiffsCrk-FtEustis.1038</Name>
    <LastEdit Timestamp="2025-08-19T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FTEUSTIS" b2="115 KV" b3="34T1038" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FTEUSTIS" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FTEUSTIS" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="115 KV" b3="103872" />
      <ContingencyEquipment Action="L" Type="LN" b1="FTEUSTIS" b2="115 KV" b3="FTE-SKFF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="115 KV" b3="ZT1038" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34060</SeqNum>
    <Name>L115.Peninsula-Magruder-ShellBank.42</Name>
    <LastEdit Timestamp="2026-04-15T09:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MAGRUDER" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAGRUDER" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MAGRUDER" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAGRUDER" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="MAGRUDER" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAGRUDER" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENINSLA" b2="115 KV" b3="4202" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENINSLA" b2="115 KV" b3="42A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELLBNK" b2="115 KV" b3="4252" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHELLBNK" b2="115 KV" b3="42B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34070</SeqNum>
    <Name>L115.Harrisonbg-PeachG-WeyersCv-Verona-Staunton.43</Name>
    <LastEdit Timestamp="2026-04-16T13:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="115 KV" b3="4392" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRSNBG" b2="115 KV" b3="43A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PEACHGDP" b2="115 KV" b3="43A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NRIVERDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEACHGDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAUNTON" b2="115 KV" b3="4372" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAUNTON" b2="115 KV" b3="H5T43" />
      <ContingencyEquipment Action="L" Type="LN" b1="VERONA" b2="115 KV" b3="43D" />
      <ContingencyEquipment Action="X" Type="XF" b1="VERONA" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VERONA" b2="22 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="VERONA" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VERONA" b2="22 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="WEYERSCV" b2="115 KV" b3="43B" />
      <ContingencyEquipment Action="L" Type="LN" b1="WEYERSCV" b2="115 KV" b3="43C" />
      <ContingencyEquipment Action="X" Type="XF" b1="WEYERSCV" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WEYERSCV" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34080</SeqNum>
    <Name>L115.Henderson-Kerrdam.45</Name>
    <LastEdit Timestamp="2026-04-17T14:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KERR45" b2="115 KV" b3="45A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="125" />
      <ContingencyEquipment Action="L" Type="LN" b1="WARRENT" b2="115 KV" b3="45B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34100</SeqNum>
    <Name>L115.SewellsPoint-TholeStreet.48</Name>
    <LastEdit Timestamp="2026-04-14T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SEWELLPT" b2="115 KV" b3="48A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="115 KV" b3="48T107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="115 KV" b3="L572" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOLEST" b2="115 KV" b3="48T182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOLEST" b2="115 KV" b3="48T196" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34110</SeqNum>
    <Name>L115.Chesterfield-Kevlar.53</Name>
    <LastEdit Timestamp="2025-06-13T09:30:23" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="115 KV" b3="5312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEVLAR" b2="115 KV" b3="5372" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEVLAR" b2="115 KV" b3="53A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34120</SeqNum>
    <Name>L115.Occoneeche-Jackson-Woodland-Auland-Earleys.54</Name>
    <LastEdit Timestamp="2024-10-28T12:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EARLEYS" b2="115 KV" b3="54D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AULANDDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="115 KV" b3="5462" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="115 KV" b3="YT54" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSNDP" b2="115 KV" b3="54B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JACKSNDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCONECHE" b2="115 KV" b3="5412" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSNDP" b2="115 KV" b3="54E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCONECHE" b2="115 KV" b3="54T1028" />
      <ContingencyEquipment Action="L" Type="LN" b1="AULANDDP" b2="115 KV" b3="54C" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODLAN4" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODLAN4" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34130</SeqNum>
    <Name>L115.Boykins-Margarettsville-Seaboard-Pecan.56</Name>
    <LastEdit Timestamp="2024-10-16T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOYKINS" b2="115 KV" b3="5632" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARGARTV" b2="115 KV" b3="56A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARGARTV" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PECAN" b2="115 KV" b3="5682" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PECAN" b2="115 KV" b3="56T1010" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEABOARD" b2="115 KV" b3="56B" />
      <ContingencyEquipment Action="L" Type="LN" b1="PECAN" b2="115 KV" b3="56C2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEABOARD" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SEABOARD" b2="13 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34140</SeqNum>
    <Name>L115.Lanexa-NwprtRs-Tno-KngsMl-SkiffesC.19/169/177</Name>
    <LastEdit Timestamp="2024-10-30T15:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="KINGSMIL" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSMIL" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="115 KV" b3="17732" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANEXA" b2="115 KV" b3="177B" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWPORTR" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWPORTR" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="115 KV" b3="1972" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGSMIL" b2="115 KV" b3="19A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="115 KV" b3="19T58" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGSMIL" b2="115 KV" b3="169A" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWPORTR" b2="115 KV" b3="177A" />
      <ContingencyEquipment Action="X" Type="XF" b1="TOANO" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TOANO" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="TOANO" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TOANO" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34150</SeqNum>
    <Name>L115.Acca-Northwest.60</Name>
    <LastEdit Timestamp="2026-04-14T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ACCA" b2="115 KV" b3="6072" />
      <ContingencyEquipment Action="L" Type="LN" b1="ACCA" b2="115 KV" b3="60A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWEST" b2="115 KV" b3="6052" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34160</SeqNum>
    <Name>L115.Whealton-Warwick-Colony-Yorktown.61</Name>
    <LastEdit Timestamp="2026-04-16T13:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLONY" b2="115 KV" b3="61B" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLONY" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COLONY" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLONY" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COLONY" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLONY" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COLONY" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="L" Type="LN" b1="WARWICK" b2="115 KV" b3="61A" />
      <ContingencyEquipment Action="X" Type="XF" b1="WARWICK" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WARWICK" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WARWICK" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WARWICK" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEALTON" b2="115 KV" b3="6142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="115 KV" b3="6182" />
      <ContingencyEquipment Action="L" Type="LN" b1="YORKTOW4" b2="115 KV" b3="61C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34170</SeqNum>
    <Name>L115.Chesapeake-Gosport.62</Name>
    <LastEdit Timestamp="2025-10-27T10:58:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="115 KV" b3="6222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOSPORT" b2="115 KV" b3="6272" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOSPORT" b2="115 KV" b3="62A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34180</SeqNum>
    <Name>L115.Basin-Pipline-TwelfthStreet.63</Name>
    <LastEdit Timestamp="2026-04-14T09:25:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASIN" b2="115 KV" b3="6342" />
      <ContingencyEquipment Action="L" Type="LN" b1="BASIN" b2="115 KV" b3="63A" />
      <ContingencyEquipment Action="L" Type="LN" b1="PIPELINE" b2="115 KV" b3="63B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PIPELINE" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWELFTHS" b2="115 KV" b3="H6T63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWELFTHS" b2="115 KV" b3="H7T63" />
      <ContingencyEquipment Action="X" Type="XF" b1="TWELFTHS" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TWELFTHS" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34210</SeqNum>
    <Name>L115.Chesapeake-Cradock.66</Name>
    <LastEdit Timestamp="2026-04-14T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="115 KV" b3="6622" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRADOCK" b2="115 KV" b3="6632" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRADOCK" b2="115 KV" b3="66A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CRADOCK" b2="115 KV" b3="66T110" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34220</SeqNum>
    <Name>L115.Greenwich-DavisCorner-Burton.67</Name>
    <LastEdit Timestamp="2025-04-07T15:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTON" b2="115 KV" b3="67T166" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTON" b2="115 KV" b3="67T181" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAVISCNR" b2="115 KV" b3="67C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISCNR" b2="115 KV" b3="H182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISCNR" b2="115 KV" b3="H282" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISCNR" b2="115 KV" b3="H482" />
      <ContingencyEquipment Action="X" Type="XF" b1="DAVISCNR" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAVISCNR" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DAVISCNR" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAVISCNR" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="DAVISCNR" b2="115 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAVISCNR" b2="13 KV" b3="TX4" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAVISCNR" b2="115 KV" b3="67D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="115 KV" b3="67T135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="115 KV" b3="L2T67" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34230</SeqNum>
    <Name>L115.Suffolk-Copeland-Holland-UnionCamp.68</Name>
    <LastEdit Timestamp="2025-12-24T11:37:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COPELNDP" b2="115 KV" b3="COP-HOLL" />
      <ContingencyEquipment Action="L" Type="LN" b1="COPELNDP" b2="115 KV" b3="COP-SUFF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COPELNDP" b2="115 KV" b3="DP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOLLAND" b2="115 KV" b3="HOLLNDP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOLLAND" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="115 KV" b3="L2T68" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="115 KV" b3="L5T68" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIONCMP" b2="115 KV" b3="6882" />
      <ContingencyEquipment Action="L" Type="LN" b1="UNIONCMP" b2="115 KV" b3="68B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34240</SeqNum>
    <Name>TEMP:L115.Chesterfield-Reymet-KingsLanding</Name>
    <LastEdit Timestamp="2025-09-15T16:37:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="115 KV" b3="7212" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KINGSLND" b2="115 KV" b3="7266" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSLND" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSLND" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="REYMET" b2="115 KV" b3="72A" />
      <ContingencyEquipment Action="L" Type="LN" b1="REYMET" b2="115 KV" b3="72B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REYMET" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34250</SeqNum>
    <Name>L115.Elmont-Hanover-FourRivers.73</Name>
    <LastEdit Timestamp="2026-04-16T13:47:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="115 KV" b3="7392" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMONT4" b2="115 KV" b3="73A" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOURRIVR" b2="115 KV" b3="73B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="115 KV" b3="73T1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="115 KV" b3="73T175" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HANOVER4" b2="115 KV" b3="SC1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HANOVER4" b2="115 KV" b3="TX5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HANOVER4" b2="13 KV" b3="TX5LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34260</SeqNum>
    <Name>L115.Chesapeake-ComNatGas-GrassField-Shillelagh.74</Name>
    <LastEdit Timestamp="2026-01-06T17:08:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="115 KV" b3="7422" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHESAPKE" b2="115 KV" b3="7428" />
      <ContingencyEquipment Action="L" Type="LN" b1="COMNATGS" b2="115 KV" b3="74CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="COMNATGS" b2="115 KV" b3="74D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COMNATGS" b2="115 KV" b3="H152" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COMNATGS" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRASSFID" b2="115 KV" b3="GRA-SHIL" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRASSFID" b2="35 KV" b3="GRASFDSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRASSFID" b2="115 KV" b3="H172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRASSFID" b2="115 KV" b3="H272" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRASSFID" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRASSFID" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRASSFID" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRASSFID" b2="35 KV" b3="TX2 LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHILLAGH" b2="115 KV" b3="7492" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHILLAGH" b2="115 KV" b3="74T1053" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34270</SeqNum>
    <Name>L115.Peninsula-Seaford-Yorktown.76</Name>
    <LastEdit Timestamp="2026-04-16T13:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENINSLA" b2="115 KV" b3="7602" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEAFORD" b2="115 KV" b3="76A" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEAFORD" b2="115 KV" b3="76B" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEAFORD" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SEAFORD" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="115 KV" b3="7682" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34280</SeqNum>
    <Name>L115.Carolina-RoanokeRapids.77</Name>
    <LastEdit Timestamp="2026-04-15T09:09:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAROLINA" b2="115 KV" b3="7702" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CAROLINA" b2="115 KV" b3="7708" />
      <ContingencyEquipment Action="L" Type="LN" b1="RORAPIDS" b2="115 KV" b3="77A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RORAPIDS" b2="14 KV" b3="G1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RORAPIDS" b2="14 KV" b3="G2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RORAPIDS" b2="14 KV" b3="G3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RORAPIDS" b2="14 KV" b3="G4" />
      <ContingencyEquipment Action="X" Type="XF" b1="RORAPIDS" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="RORAPIDS" b2="115 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34290</SeqNum>
    <Name>L115.Pendleton-VirginiaBeach.78</Name>
    <LastEdit Timestamp="2024-10-11T16:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PENDLETN" b2="115 KV" b3="78A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENDLETN" b2="115 KV" b3="78T147" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENDLETN" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENDLETN" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="115 KV" b3="7872" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34300</SeqNum>
    <Name>L115.Peninsula-Seaford-Yorktown.79</Name>
    <LastEdit Timestamp="2026-04-16T13:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENINSLA" b2="115 KV" b3="7902" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEAFORD" b2="115 KV" b3="79A" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEAFORD" b2="115 KV" b3="79B" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEAFORD" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SEAFORD" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="115 KV" b3="7982" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34310</SeqNum>
    <Name>L115.Battleboro-CDiesel-Whitakers-Chestnut.1001</Name>
    <LastEdit Timestamp="2025-12-04T16:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BATTLEBO" b2="115 KV" b3="100142" />
      <ContingencyEquipment Action="L" Type="LN" b1="BATTLEBO" b2="115 KV" b3="1001A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTNT" b2="115 KV" b3="10011024" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTNT" b2="115 KV" b3="100182" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTNT" b2="115 KV" b3="1001E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONSLDSL" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="WHITAKER" b2="115 KV" b3="1001B" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHITAKER" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHITAKER" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHITAKER" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHITAKER" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WHITAKER" b2="35 KV" b3="WHITKSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34320</SeqNum>
    <Name>L115.Lanexa-WestPoint-Shackleford-GoaldersCreek.85</Name>
    <LastEdit Timestamp="2025-05-30T11:10:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLDRSCRK" b2="115 KV" b3="85T1060" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLDRSCRK" b2="115 KV" b3="85T1071" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="115 KV" b3="8532" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHACKLFD" b2="115 KV" b3="85B" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLDRSCRK" b2="115 KV" b3="GLD-SHAC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SHACKLFD" b2="35 KV" b3="PENISULA" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SHACKLFD" b2="35 KV" b3="SHACKLF" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHACKLFD" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHACKLFD" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WSTPOINT" b2="115 KV" b3="85C" />
      <ContingencyEquipment Action="X" Type="XF" b1="WSTPOINT" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WSTPOINT" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WSTPOINT" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WSTPOINT" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34330</SeqNum>
    <Name>L115.Chesterfield-Northwest.86</Name>
    <LastEdit Timestamp="2026-04-16T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CENTRLIA" b2="115 KV" b3="86A" />
      <ContingencyEquipment Action="X" Type="XF" b1="CENTRLIA" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CENTRLIA" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CENTRLIA" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CENTRLIA" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="115 KV" b3="8612" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWEST" b2="115 KV" b3="8652" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIVERRD" b2="115 KV" b3="86C" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIVERRD" b2="115 KV" b3="86D" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIVERRD" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERRD" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIVERRD" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERRD" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="STRATFRD" b2="115 KV" b3="86B" />
      <ContingencyEquipment Action="X" Type="XF" b1="STRATFRD" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STRATFRD" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="STRATFRD" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STRATFRD" b2="13 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34350</SeqNum>
    <Name>L115.ForkUnion-KiddsStoreDP-Transco-WalnutCreek.91</Name>
    <LastEdit Timestamp="2026-06-04T12:08:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRKUNION" b2="115 KV" b3="9172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRKUNION" b2="115 KV" b3="91T1030" />
      <ContingencyEquipment Action="L" Type="LN" b1="KIDDSTDP" b2="115 KV" b3="91E" />
      <ContingencyEquipment Action="L" Type="LN" b1="KIDDSTDP" b2="115 KV" b3="KID-TRAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KIDDSTDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRANSCO" b2="115 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRANSCO" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALNTCRK" b2="115 KV" b3="91T1067" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALNTCRK" b2="115 KV" b3="91T1068" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WALNTCRK" b2="115 KV" b3="SC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRANSCO" b2="115 KV" b3="TRA-WALN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34360</SeqNum>
    <Name>L115.Chesterfield-Turner-Chick-ProvForge-Lanexa.92</Name>
    <LastEdit Timestamp="2025-12-04T17:42:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="115 KV" b3="9212" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTER4" b2="115 KV" b3="92A" />
      <ContingencyEquipment Action="S" Type="SD" b1="CHICKHOM" b2="115 KV" b3="92D" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICKHOM" b2="115 KV" b3="CHI-PROV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="115 KV" b3="9232" />
      <ContingencyEquipment Action="L" Type="LN" b1="PROVFORG" b2="115 KV" b3="92C" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PROVFORG" b2="35 KV" b3="CHARLESC" />
      <ContingencyEquipment Action="X" Type="XF" b1="PROVFORG" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PROVFORG" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICKHOM" b2="115 KV" b3="CHI-TURN" />
      <ContingencyEquipment Action="X" Type="XF" b1="TURNER4" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TURNER4" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34370</SeqNum>
    <Name>L115.SHampton-WatkinsC-Franklin-Pret-UnionCamp.93</Name>
    <LastEdit Timestamp="2026-04-06T12:49:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FRANKLI4" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRANKLI4" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="FRANKLI4" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRANKLI4" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKLI4" b2="115 KV" b3="FRA-PRET" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PRETLWDP" b2="115 KV" b3="LD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHAMPTON" b2="115 KV" b3="93A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAMPTON" b2="115 KV" b3="93T140" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SHAMPTON" b2="115 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAMPTON" b2="115 KV" b3="G152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIONCMP" b2="115 KV" b3="9382" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRETLWDP" b2="115 KV" b3="PRE-UNIO" />
      <ContingencyEquipment Action="L" Type="LN" b1="WTKINSCR" b2="115 KV" b3="93B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WTKINSCR" b2="115 KV" b3="H162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WTKINSCR" b2="115 KV" b3="H262" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WTKINSCR" b2="35 KV" b3="NOTTOWAY" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WTKINSCR" b2="115 KV" b3="SC3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WTKINSCR" b2="115 KV" b3="SC4" />
      <ContingencyEquipment Action="X" Type="XF" b1="WTKINSCR" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WTKINSCR" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WTKINSCR" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WTKINSCR" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34380</SeqNum>
    <Name>L115.IndustrialPark-ReevesAvenue.94</Name>
    <LastEdit Timestamp="2024-11-15T11:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDUSTPK" b2="115 KV" b3="9442" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="115 KV" b3="9412" />
      <ContingencyEquipment Action="L" Type="LN" b1="REEVESAV" b2="115 KV" b3="94A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34390</SeqNum>
    <Name>L115.Peninsula-Whealton.99</Name>
    <LastEdit Timestamp="2026-04-16T13:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENINSLA" b2="115 KV" b3="9902" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENINSLA" b2="115 KV" b3="99A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEALTON" b2="115 KV" b3="9942" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34400</SeqNum>
    <Name>L115.Northeast-Carver.3</Name>
    <LastEdit Timestamp="2026-04-16T13:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARVER" b2="115 KV" b3="362" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARVER" b2="115 KV" b3="3A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="115 KV" b3="362-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="115 KV" b3="362-9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34410</SeqNum>
    <Name>L115.Remington-RemingtonCT.6</Name>
    <LastEdit Timestamp="2026-04-15T09:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGTN" b2="115 KV" b3="642" />
      <ContingencyEquipment Action="L" Type="LN" b1="REMINGTN" b2="115 KV" b3="6A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="115 KV" b3="L9T6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34420</SeqNum>
    <Name>L138.Bremo-Scottsville + 138/115.Bremo.TX8A&amp;8B</Name>
    <LastEdit Timestamp="2025-11-10T12:13:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="115 KV" b3="822" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCOTTSVI" b2="138 KV" b3="SCO-BRE1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BREMO4" b2="138 KV" b3="TX8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOTTSVI" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34430</SeqNum>
    <Name>L115.BalconyFalls-Glasgow-Effinger-Lexington.9</Name>
    <LastEdit Timestamp="2025-05-29T14:29:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BALCFALL" b2="115 KV" b3="912CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALCFALL" b2="115 KV" b3="9T28CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EFFINGER" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLASGOW4" b2="115 KV" b3="9B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BALCFALL" b2="115 KV" b3="9C" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLASGOW4" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLASGOW4" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLASGOW4" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLASGOW4" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEXINGTN" b2="115 KV" b3="9A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="115 KV" b3="9T194" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="115 KV" b3="L4T9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34460</SeqNum>
    <Name>500.Morrisville.Cap</Name>
    <LastEdit Timestamp="2026-04-15T09:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="MORRISVL" b2="500 KV" b3="SC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="500 KV" b3="SC122" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34470</SeqNum>
    <Name>MtStorm.U1</Name>
    <LastEdit Timestamp="2026-05-11T09:09:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MTSTORM4" b2="22 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="G1TB3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="G1TB4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTSTORM4" b2="22 KV" b3="SS1LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="MTSTORM4" b2="500 KV" b3="TXG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34480</SeqNum>
    <Name>MtStorm.U2</Name>
    <LastEdit Timestamp="2026-05-11T09:10:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MTSTORM4" b2="22 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="G2TB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="G2TB2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTSTORM4" b2="22 KV" b3="SS2LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="MTSTORM4" b2="500 KV" b3="TXG2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34490</SeqNum>
    <Name>500.MtStorm.Cap.SC2</Name>
    <LastEdit Timestamp="2024-10-22T16:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="MTSTORM4" b2="500 KV" b3="SC2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34500</SeqNum>
    <Name>500/230.NorthAnna.TX5</Name>
    <LastEdit Timestamp="2026-04-16T13:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="500 KV" b3="H502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="230 KV" b3="L502" />
      <ContingencyEquipment Action="X" Type="XF" b1="NANNA4" b2="500 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34510</SeqNum>
    <Name>500/230.NorthAnna.TX6</Name>
    <LastEdit Timestamp="2026-04-16T13:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="230 KV" b3="H3TL6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="500 KV" b3="H602" />
      <ContingencyEquipment Action="X" Type="XF" b1="NANNA4" b2="500 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34520</SeqNum>
    <Name>L115.Carolina-Occoneechee.1028</Name>
    <LastEdit Timestamp="2025-04-28T10:33:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAROLINA" b2="115 KV" b3="102802" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CAROLINA" b2="115 KV" b3="102808" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAROLINA" b2="115 KV" b3="1028A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCONECHE" b2="115 KV" b3="102812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCONECHE" b2="115 KV" b3="54T1028" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34530</SeqNum>
    <Name>Occoneechee.SP</Name>
    <LastEdit Timestamp="2025-04-28T15:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OCONECHE" b2="115 KV" b3="102812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCONECHE" b2="115 KV" b3="5412" />
      <ContingencyEquipment Action="X" Type="XF" b1="OCONECHE" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OCONECHE" b2="34.5 KV" b3="GUTNBGSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34580</SeqNum>
    <Name>230/115.Poe.TX5</Name>
    <LastEdit Timestamp="2026-04-16T13:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POE" b2="230 KV" b3="H552" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POE" b2="115 KV" b3="L552" />
      <ContingencyEquipment Action="X" Type="XF" b1="POE" b2="230 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34600</SeqNum>
    <Name>230/115.PossumPoint.TX9</Name>
    <LastEdit Timestamp="2024-06-12T14:56:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="H992" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="H9T237" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="115 KV" b3="L992" />
      <ContingencyEquipment Action="X" Type="XF" b1="POSSUMP4" b2="230 KV" b3="TX9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34650</SeqNum>
    <Name>RemingtonCT.U1+U2</Name>
    <LastEdit Timestamp="2026-04-17T15:06:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="REMNTNCT" b2="18 KV" b3="GT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="GT162" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REMNTNCT" b2="18 KV" b3="GT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="GT262" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="SX1262" />
      <ContingencyEquipment Action="X" Type="XF" b1="REMNTNCT" b2="230 KV" b3="TX12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REMNTNCT" b2="35 KV" b3="TX12" />
      <ContingencyEquipment Action="X" Type="XF" b1="REMNTNCT" b2="230 KV" b3="TXG1" />
      <ContingencyEquipment Action="X" Type="XF" b1="REMNTNCT" b2="230 KV" b3="TXG2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34660</SeqNum>
    <Name>RemingtonCT.U3+U4</Name>
    <LastEdit Timestamp="2026-04-17T15:11:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="REMNTNCT" b2="18 KV" b3="GT3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="GT362" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REMNTNCT" b2="18 KV" b3="GT4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="GT462" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="SX3462" />
      <ContingencyEquipment Action="X" Type="XF" b1="REMNTNCT" b2="230 KV" b3="TX34" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REMNTNCT" b2="35 KV" b3="TX34" />
      <ContingencyEquipment Action="X" Type="XF" b1="REMNTNCT" b2="230 KV" b3="TXG3" />
      <ContingencyEquipment Action="X" Type="XF" b1="REMNTNCT" b2="230 KV" b3="TXG4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34680</SeqNum>
    <Name>L138.Tuscany-Delano</Name>
    <LastEdit Timestamp="2026-04-17T14:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELANO" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELANO" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELANO" b2="138 KV" b3="DEL-TUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUSCANY" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUSCANY" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34690</SeqNum>
    <Name>Surry.U1</Name>
    <LastEdit Timestamp="2026-02-11T06:47:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="SURRY4" b2="22 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="G102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="G1T240" />
      <ContingencyEquipment Action="X" Type="XF" b1="SURRY4" b2="22 KV" b3="SS1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SURRY4" b2="4 KV" b3="SS1LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="SURRY4" b2="230 KV" b3="TXG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34700</SeqNum>
    <Name>Surry.U2</Name>
    <LastEdit Timestamp="2026-02-11T06:47:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="SURRY4" b2="22 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="500 KV" b3="G202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="500 KV" b3="G2T567" />
      <ContingencyEquipment Action="X" Type="XF" b1="SURRY4" b2="22 KV" b3="SS2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SURRY4" b2="4 KV" b3="SS2LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="SURRY4" b2="500 KV" b3="TXG2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34710</SeqNum>
    <Name>230/115.Suffolk.TX2</Name>
    <LastEdit Timestamp="2026-04-16T13:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="230 KV" b3="H242CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="115 KV" b3="L2T23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="115 KV" b3="L2T68" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUFFOLK" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34780</SeqNum>
    <Name>L230.Loudoun-CubRun-Walney-LincolnPrk.2008</Name>
    <LastEdit Timestamp="2026-01-27T10:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CUBRUNDP" b2="230 KV" b3="2008B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CUBRUNDP" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLNP" b2="230 KV" b3="20082242" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLNP" b2="230 KV" b3="200872" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="20082045" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="200852" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOUDOUN4" b2="230 KV" b3="2008A" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLNP" b2="230 KV" b3="LIN-WALN" />
      <ContingencyEquipment Action="X" Type="XF" b1="WALNEY" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALNEY" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34790</SeqNum>
    <Name>L230.Clifton-BatteryHts-PrinceWilliam-BrickYd.2011</Name>
    <LastEdit Timestamp="2026-01-06T11:27:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BATERYHT" b2="230 KV" b3="2011A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BATERYHT" b2="230 KV" b3="2011B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BATERYHT" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRICKYRD" b2="230 KV" b3="20112239" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRICKYRD" b2="230 KV" b3="201132" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRICKYRD" b2="230 KV" b3="BRI-PRIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTON" b2="230 KV" b3="201182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTON" b2="230 KV" b3="XT2011" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PRINCWIL" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34800</SeqNum>
    <Name>L230.Clifton-Pender.2051</Name>
    <LastEdit Timestamp="2026-04-20T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTON" b2="230 KV" b3="20512063" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTON" b2="230 KV" b3="205182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENDER" b2="230 KV" b3="200T2051" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENDER" b2="230 KV" b3="2051A" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENDER" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENDER" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENDER" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENDER" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34810</SeqNum>
    <Name>L230.Clifton-Ox.2063</Name>
    <LastEdit Timestamp="2026-04-20T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTON" b2="230 KV" b3="20512063" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTON" b2="230 KV" b3="206382" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLIFTON" b2="230 KV" b3="2063A" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOOREDP" b2="230 KV" b3="2063B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MOOREDP" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="206342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="220T2063" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34820</SeqNum>
    <Name>L230.Remington-RemingtonCT.2077</Name>
    <LastEdit Timestamp="2025-04-10T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGTN" b2="230 KV" b3="20772199" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGTN" b2="230 KV" b3="207742" />
      <ContingencyEquipment Action="L" Type="LN" b1="REMINGTN" b2="230 KV" b3="2077A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="20772086" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="207762" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34850</SeqNum>
    <Name>L230.Brambleton-Altair.201</Name>
    <LastEdit Timestamp="2025-02-18T20:40:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAIR" b2="230 KV" b3="20172-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAIR" b2="230 KV" b3="20172-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="20102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="201T2319" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALTAIR" b2="230 KV" b3="ALT-BRAM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34860</SeqNum>
    <Name>L230.Everetts-Greenville.218 [CPL]</Name>
    <LastEdit Timestamp="2024-05-14T10:30:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EVERETTS" b2="230 KV" b3="218" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERETTS" b2="230 KV" b3="218T2160" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERETTS" b2="230 KV" b3="H2T218" />
      <ContingencyEquipment Action="X" Type="XF" b1="EVERETTS" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EVERETTS" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENVIL" b2="230 KV" b3="6EVRGUC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENVIL" b2="230 KV" b3="6EVRKDSS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34870</SeqNum>
    <Name>L230.GumSprings-Belvoir-Franconia-Ox.220</Name>
    <LastEdit Timestamp="2026-04-20T11:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELVOIR" b2="230 KV" b3="220A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELVOIR" b2="230 KV" b3="220B" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELVOIR" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELVOIR" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="FRANCONA" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRANCONA" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUMSPRNG" b2="230 KV" b3="204T220" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUMSPRNG" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GUMSPRNG" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="22042" />
      <ContingencyEquipment Action="L" Type="LN" b1="OX4" b2="230 KV" b3="220C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="220T2063" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34880</SeqNum>
    <Name>L230.Earleys-Firetower-Nucor-Suffolk.246</Name>
    <LastEdit Timestamp="2026-04-14T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="24662" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="246T2034" />
      <ContingencyEquipment Action="L" Type="LN" b1="EARLEYS" b2="230 KV" b3="EAR-FIRE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FIRETOWR" b2="230 KV" b3="LD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NUCOR4" b2="230 KV" b3="246AB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NUCOR4" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIRETOWR" b2="230 KV" b3="FIR-NUCO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="230 KV" b3="24642" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUFFOLK" b2="230 KV" b3="246B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="230 KV" b3="246T247" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34900</SeqNum>
    <Name>L230.BullRun-JohnsonsDP-Walney-Sully.265</Name>
    <LastEdit Timestamp="2025-07-28T11:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRUN" b2="230 KV" b3="26562" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRUN" b2="230 KV" b3="265T2212" />
      <ContingencyEquipment Action="L" Type="LN" b1="BULLRUN" b2="230 KV" b3="BUL-JOHN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JOHNSNDP" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SULLY" b2="230 KV" b3="265C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLY" b2="230 KV" b3="265T2107" />
      <ContingencyEquipment Action="X" Type="XF" b1="SULLY" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SULLY" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="WALNEY" b2="230 KV" b3="265B" />
      <ContingencyEquipment Action="X" Type="XF" b1="WALNEY" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALNEY" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="WALNEY" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALNEY" b2="34.5 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34910</SeqNum>
    <Name>L230.GlCarlyn-FlsChurc-GallowsRd-Keene-Clifton.266</Name>
    <LastEdit Timestamp="2025-10-27T10:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRADDOCK" b2="230 KV" b3="266-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADDOCK" b2="230 KV" b3="SR172" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRADDOCK" b2="230 KV" b3="SR_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTON" b2="230 KV" b3="26682" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTON" b2="230 KV" b3="266T2212" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLSCHURC" b2="230 KV" b3="266A" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLSCHURC" b2="230 KV" b3="266B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLSCHURC" b2="230 KV" b3="H432" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLSCHURC" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLSCHURC" b2="35 KV" b3="TX4" />
      <ContingencyEquipment Action="X" Type="XF" b1="GALLWSRD" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GALLWSRD" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCARLYN" b2="230 KV" b3="251T266" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCARLYN" b2="230 KV" b3="266T278" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADDOCK" b2="230 KV" b3="266-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEENMILL" b2="230 KV" b3="266D" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEENMILL" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEENMILL" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34920</SeqNum>
    <Name>L230.Remington-MarshRun.280</Name>
    <LastEdit Timestamp="2025-04-10T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHRUN" b2="230 KV" b3="28002" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARSHRUN" b2="230 KV" b3="280A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHRUN" b2="230 KV" b3="280T2039" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGTN" b2="230 KV" b3="28042" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGTN" b2="230 KV" b3="280T2199" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34930</SeqNum>
    <Name>L230.Chuckatuck-KingsFork-Suffolk.289</Name>
    <LastEdit Timestamp="2026-04-17T15:11:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHUCKATK" b2="230 KV" b3="263T289" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHUCKATK" b2="230 KV" b3="289T290" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CHUCKATK" b2="230 KV" b3="SC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGSFRK" b2="230 KV" b3="289A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KINGSFRK" b2="35 KV" b3="GARDFMSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="KINGSFRK" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSFRK" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="KINGSFRK" b2="230 KV" b3="TX_2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSFRK" b2="35 KV" b3="TX_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="230 KV" b3="28942" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUFFOLK" b2="230 KV" b3="289B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="230 KV" b3="289T2110" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34940</SeqNum>
    <Name>L230.MarshRun-RemingtonCT.299</Name>
    <LastEdit Timestamp="2026-04-20T11:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHRUN" b2="230 KV" b3="29902" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHRUN" b2="230 KV" b3="299T2040" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="29962" />
      <ContingencyEquipment Action="L" Type="LN" b1="REMNTNCT" b2="230 KV" b3="299A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="H9T299" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>34950</SeqNum>
    <Name>MtStorm.U3</Name>
    <LastEdit Timestamp="2026-01-12T12:54:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MTSTORM4" b2="22 KV" b3="G3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="G3TB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="G3TB2" />
      <ContingencyEquipment Action="X" Type="XF" b1="MTSTORM4" b2="500 KV" b3="TXG3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35020</SeqNum>
    <Name>Chesapeake.GT6</Name>
    <LastEdit Timestamp="2026-04-17T15:12:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="115 KV" b3="GT22" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESAPKE" b2="13.8 KV" b3="GT6" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESAPKE" b2="115 KV" b3="TGT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35060</SeqNum>
    <Name>Chesterfield.U7</Name>
    <LastEdit Timestamp="2026-04-16T13:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="G712" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESTER4" b2="14 KV" b3="G7G" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESTER4" b2="14 KV" b3="G7S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="G7T2049" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTER4" b2="230 KV" b3="TG7G" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTER4" b2="230 KV" b3="TG7S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35070</SeqNum>
    <Name>Chesterfield.U8</Name>
    <LastEdit Timestamp="2026-04-16T13:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="G812" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESTER4" b2="14 KV" b3="G8G" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESTER4" b2="14 KV" b3="G8S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="G8TH9" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTER4" b2="230 KV" b3="TG8G" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTER4" b2="230 KV" b3="TG8S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35080</SeqNum>
    <Name>Darbytown.U1</Name>
    <LastEdit Timestamp="2026-04-16T13:45:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARBYTWN" b2="14 KV" b3="G182" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DARBYTWN" b2="14 KV" b3="GT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35090</SeqNum>
    <Name>Darbytown.U2</Name>
    <LastEdit Timestamp="2026-04-16T13:45:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARBYTWN" b2="14 KV" b3="G282" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DARBYTWN" b2="14 KV" b3="GT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35100</SeqNum>
    <Name>Darbytown.U3</Name>
    <LastEdit Timestamp="2026-04-17T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARBYTWN" b2="14 KV" b3="G382" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DARBYTWN" b2="14 KV" b3="GT3" />
      <ContingencyEquipment Action="X" Type="XF" b1="DARBYTWN" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35110</SeqNum>
    <Name>Darbytown.U4</Name>
    <LastEdit Timestamp="2026-04-17T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARBYTWN" b2="14 KV" b3="G482" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DARBYTWN" b2="14 KV" b3="GT4" />
      <ContingencyEquipment Action="X" Type="XF" b1="DARBYTWN" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35120</SeqNum>
    <Name>L230.Surry-GravelNeck &amp; GravelNeck.UGTS</Name>
    <LastEdit Timestamp="2026-04-20T11:54:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SURRY4" b2="230 KV" b3="BUS8Z" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAVLNK" b2="13 KV" b3="GT192" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAVLNK" b2="13 KV" b3="GT292" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRAVLNK" b2="13 KV" b3="GTS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRAVLNK" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRAVLNK" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="GT02" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35130</SeqNum>
    <Name>Kerr Dam.U1</Name>
    <LastEdit Timestamp="2026-04-17T15:16:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="15" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KERRDAM" b2="14 KV" b3="G1" />
      <ContingencyEquipment Action="X" Type="XF" b1="KERRDAM" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35140</SeqNum>
    <Name>Kerr Dam.U2</Name>
    <LastEdit Timestamp="2026-04-17T15:16:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="35" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KERRDAM" b2="14 KV" b3="G2" />
      <ContingencyEquipment Action="X" Type="XF" b1="KERRDAM" b2="115 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35150</SeqNum>
    <Name>Kerr Dam.U3</Name>
    <LastEdit Timestamp="2026-04-17T15:16:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="55" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KERRDAM" b2="14 KV" b3="G3" />
      <ContingencyEquipment Action="X" Type="XF" b1="KERRDAM" b2="115 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35160</SeqNum>
    <Name>Kerr Dam.U4</Name>
    <LastEdit Timestamp="2026-04-17T15:17:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="72" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="75" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KERRDAM" b2="14 KV" b3="G4" />
      <ContingencyEquipment Action="X" Type="XF" b1="KERRDAM" b2="115 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35170</SeqNum>
    <Name>Kerr Dam.U5</Name>
    <LastEdit Timestamp="2026-04-17T15:17:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="92" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="95" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KERRDAM" b2="14 KV" b3="G5" />
      <ContingencyEquipment Action="X" Type="XF" b1="KERRDAM" b2="115 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35180</SeqNum>
    <Name>Kerr Dam.U6</Name>
    <LastEdit Timestamp="2026-04-20T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="115" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KERRDAM" b2="14 KV" b3="G6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35190</SeqNum>
    <Name>Kerr Dam.U7</Name>
    <LastEdit Timestamp="2026-04-20T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="135" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KERRDAM" b2="14 KV" b3="G7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35220</SeqNum>
    <Name>Louisa.U1&amp;2</Name>
    <LastEdit Timestamp="2024-12-03T14:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="LOUISACT" b2="13.8 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISACT" b2="230 KV" b3="G12T2074" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISACT" b2="230 KV" b3="G12TG34" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LOUISACT" b2="13.8 KV" b3="G2" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOUISACT" b2="230 KV" b3="TG1" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOUISACT" b2="230 KV" b3="TG2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35230</SeqNum>
    <Name>Louisa.U3&amp;4</Name>
    <LastEdit Timestamp="2024-12-03T14:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISACT" b2="230 KV" b3="G12TG34" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LOUISACT" b2="13.8 KV" b3="G3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISACT" b2="230 KV" b3="G34T2088" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LOUISACT" b2="13.8 KV" b3="G4" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOUISACT" b2="230 KV" b3="TG3" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOUISACT" b2="230 KV" b3="TG4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35240</SeqNum>
    <Name>Louisa.U5</Name>
    <LastEdit Timestamp="2026-04-21T09:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="LOUISACT" b2="18 KV" b3="G5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISACT" b2="230 KV" b3="G5T2074" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISACT" b2="230 KV" b3="G5T2088" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOUISACT" b2="230 KV" b3="TG5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35250</SeqNum>
    <Name>Lowmoor.GTS</Name>
    <LastEdit Timestamp="2026-04-21T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWMOOR" b2="13 KV" b3="GT172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWMOOR" b2="13 KV" b3="GT272" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWMOOR" b2="13 KV" b3="GT372" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWMOOR" b2="13 KV" b3="GT472" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LOWMOOR" b2="13 KV" b3="GTS" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOWMOOR" b2="138 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35260</SeqNum>
    <Name>Marsh Run.U1+U2</Name>
    <LastEdit Timestamp="2026-04-21T09:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHRUN" b2="230 KV" b3="28002" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHRUN" b2="230 KV" b3="29902" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MARSHRUN" b2="18 KV" b3="GT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MARSHRUN" b2="18 KV" b3="GT2" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARSHRUN" b2="230 KV" b3="TXG1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARSHRUN" b2="230 KV" b3="TXG2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35270</SeqNum>
    <Name>Marsh Run.U3</Name>
    <LastEdit Timestamp="2026-04-21T09:40:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHRUN" b2="230 KV" b3="203902" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHRUN" b2="230 KV" b3="204002" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHRUN" b2="18 KV" b3="52-TM" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MARSHRUN" b2="18 KV" b3="GT3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARSHRUN" b2="18 KV" b3="SATB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARSHRUN" b2="230 KV" b3="TXG3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35280</SeqNum>
    <Name>MtStorm.GT1</Name>
    <LastEdit Timestamp="2026-04-21T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MTSTORM4" b2="35 KV" b3="GT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="35 KV" b3="HGT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35300</SeqNum>
    <Name>Possum Point.GT6+GT6B</Name>
    <LastEdit Timestamp="2026-04-21T09:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="POSSUMP4" b2="18 KV" b3="G6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="18 KV" b3="G6B52G" />
      <ContingencyEquipment Action="U" Type="GEN" b1="POSSUMP4" b2="18 KV" b3="GT6B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35310</SeqNum>
    <Name>Possum Point.GT6A</Name>
    <LastEdit Timestamp="2026-04-21T09:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="18 KV" b3="G6A52G" />
      <ContingencyEquipment Action="U" Type="GEN" b1="POSSUMP4" b2="18 KV" b3="GT6A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35320</SeqNum>
    <Name>Possum Point.GT6S</Name>
    <LastEdit Timestamp="2026-04-21T09:41:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="G6S92" />
      <ContingencyEquipment Action="U" Type="GEN" b1="POSSUMP4" b2="18 KV" b3="GT6S" />
      <ContingencyEquipment Action="X" Type="XF" b1="POSSUMP4" b2="230 KV" b3="TG6S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35330</SeqNum>
    <Name>Possum Point.GTS</Name>
    <LastEdit Timestamp="2026-04-21T09:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="14 KV" b3="GT12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="14 KV" b3="GT22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="14 KV" b3="GT32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="14 KV" b3="GT42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="14 KV" b3="GT52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="14 KV" b3="GT62" />
      <ContingencyEquipment Action="U" Type="GEN" b1="POSSUMP4" b2="14 KV" b3="GTS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35340</SeqNum>
    <Name>L230.Surry-Smithfld-Harborvw-Yadkin.223</Name>
    <LastEdit Timestamp="2026-04-21T09:44:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SMITHFLD" b2="230 KV" b3="223B" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HARBORVW" b2="35 KV" b3="T124" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARBORVW" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMITHFLD" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SMITHFLD" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMITHFLD" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SMITHFLD" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="22302" />
      <ContingencyEquipment Action="L" Type="LN" b1="SMITHFLD" b2="230 KV" b3="223A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="223T2048" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="22312" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARBORVW" b2="230 KV" b3="223C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="223T2070" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35350</SeqNum>
    <Name>L230.GlenCarlyn-Clarendon.277</Name>
    <LastEdit Timestamp="2026-04-21T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARENDN" b2="230 KV" b3="277T2096" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLARENDN" b2="36.5 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLARENDN" b2="230 KV" b3="TX1_" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCARLYN" b2="230 KV" b3="251T277" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCARLYN" b2="230 KV" b3="273T277" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLARENDN" b2="230 KV" b3="277A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35360</SeqNum>
    <Name>L230.GlenCarlyn-Clarendon.278</Name>
    <LastEdit Timestamp="2026-04-21T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARENDN" b2="230 KV" b3="278T2096" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARENDN" b2="230 KV" b3="H372" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLARENDN" b2="36.5 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLARENDN" b2="230 KV" b3="TX2_" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCARLYN" b2="230 KV" b3="266T278" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLARENDN" b2="230 KV" b3="278A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCARLYN" b2="230 KV" b3="278T2115" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35370</SeqNum>
    <Name>L230.Annandale-Braddock.294</Name>
    <LastEdit Timestamp="2026-04-21T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ANNANDAL" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ANNANDAL" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADDOCK" b2="230 KV" b3="207T294" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADDOCK" b2="230 KV" b3="237T294" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANNANDAL" b2="230 KV" b3="294A" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRADDOCK" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRADDOCK" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35380</SeqNum>
    <Name>L230.Annandale-Braddock.297</Name>
    <LastEdit Timestamp="2026-04-21T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ANNANDAL" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ANNANDAL" b2="35 KV" b3="TX4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADDOCK" b2="230 KV" b3="237T297" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADDOCK" b2="230 KV" b3="281T297" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANNANDAL" b2="230 KV" b3="297A" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRADDOCK" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRADDOCK" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35390</SeqNum>
    <Name>500/20.BathCounty.TR12 &amp; U1&amp;U2</Name>
    <LastEdit Timestamp="2026-03-06T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="BATHCO" b2="20 KV" b3="GM1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BATHCO" b2="20 KV" b3="GM2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="500 KV" b3="H1T547" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="500 KV" b3="H1TH3" />
      <ContingencyEquipment Action="X" Type="XF" b1="BATHCO" b2="500 KV" b3="TR12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35400</SeqNum>
    <Name>500/20.BathCounty.TR34 &amp; U3&amp;U4</Name>
    <LastEdit Timestamp="2026-03-06T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="BATHCO" b2="20 KV" b3="GM3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BATHCO" b2="20 KV" b3="GM4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="500 KV" b3="H2T547" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="500 KV" b3="H2T548" />
      <ContingencyEquipment Action="X" Type="XF" b1="BATHCO" b2="500 KV" b3="TR34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35410</SeqNum>
    <Name>500/20.BathCounty.TR56 &amp; U5&amp;U6</Name>
    <LastEdit Timestamp="2026-03-06T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="BATHCO" b2="20 KV" b3="GM5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BATHCO" b2="20 KV" b3="GM6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="500 KV" b3="H1TH3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHCO" b2="500 KV" b3="H3T548" />
      <ContingencyEquipment Action="X" Type="XF" b1="BATHCO" b2="500 KV" b3="TR56" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35430</SeqNum>
    <Name>500/35.MtStorm.RSS2</Name>
    <LastEdit Timestamp="2026-05-20T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MTSTORM4" b2="500 KV" b3="RSS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="SX2TB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="SX2TB4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="35 KV" b3="SXL22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35550</SeqNum>
    <Name>230/115.Northeast.TX7</Name>
    <LastEdit Timestamp="2025-08-12T06:31:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="230 KV" b3="H762" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="115 KV" b3="L7T17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="115 KV" b3="L7T20" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEAST" b2="230 KV" b3="TX7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35560</SeqNum>
    <Name>230/35.Southwest.TX4</Name>
    <LastEdit Timestamp="2026-04-24T08:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STHWEST" b2="230 KV" b3="H462" />
      <ContingencyEquipment Action="X" Type="XF" b1="STHWEST" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STHWEST" b2="35 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35580</SeqNum>
    <Name>L115.Shellbank-Mercury-BloxomsCorner.103</Name>
    <LastEdit Timestamp="2025-12-11T09:40:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MERCURY" b2="115 KV" b3="192A" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLOXOMSC" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLOXOMSC" b2="22 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLOXOMSC" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLOXOMSC" b2="22 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERCURY" b2="115 KV" b3="103A" />
      <ContingencyEquipment Action="X" Type="XF" b1="MERCURY" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MERCURY" b2="22 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MERCURY" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MERCURY" b2="22 KV" b3="TX2_LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELLBNK" b2="115 KV" b3="10352" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELLBNK" b2="115 KV" b3="T202" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35600</SeqNum>
    <Name>L115.Tarboro-MorsbgDP-TarRverTp-Anaconda-Hartsm.55</Name>
    <LastEdit Timestamp="2026-03-26T12:10:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ANACONDA" b2="115 KV" b3="55A" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANACONDA" b2="115 KV" b3="ANA-HART" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ANACONDA" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARTSMIL" b2="115 KV" b3="5562" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARTSMIL" b2="115 KV" b3="55T1048" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORSBGDP" b2="115 KV" b3="55B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MORSBGDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TARBORO" b2="115 KV" b3="55T105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TARBORO" b2="115 KV" b3="H272" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TARBORO" b2="115 KV" b3="L3T55" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="TARBORO" b2="115 KV" b3="SC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TARBORO" b2="115 KV" b3="TOWN-DP" />
      <ContingencyEquipment Action="L" Type="LN" b1="TARBORO5" b2="115 KV" b3="55B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TARBORO" b2="115 KV" b3="55C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TARBORO5" b2="115 KV" b3="EMCEMC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TARBORO5" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TARRIVER" b2="115 KV" b3="55A2" />
      <ContingencyEquipment Action="X" Type="XF" b1="TARRIVER" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TARRIVER" b2="13 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TARRIVER" b2="13 KV" b3="TX3_NCE" />
      <ContingencyEquipment Action="L" Type="LN" b1="TARRIVTP" b2="115 KV" b3="55A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VAUGHNDP" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35610</SeqNum>
    <Name>L115.Cradock-Shea</Name>
    <LastEdit Timestamp="2026-04-20T11:48:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRADOCK" b2="115 KV" b3="11032" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRADOCK" b2="115 KV" b3="110A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CRADOCK" b2="115 KV" b3="66T110" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHEA" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHEA" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHEA" b2="115 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHEA" b2="35 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35620</SeqNum>
    <Name>L115.Lakeside-ACCA.111</Name>
    <LastEdit Timestamp="2026-04-20T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ACCA" b2="115 KV" b3="11172" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKESID4" b2="115 KV" b3="111A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="115 KV" b3="L5T111" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="115 KV" b3="L8T111" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35630</SeqNum>
    <Name>L115.Lakeside-ACCA.95</Name>
    <LastEdit Timestamp="2026-04-20T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ACCA" b2="115 KV" b3="9572" />
      <ContingencyEquipment Action="L" Type="LN" b1="ACCA" b2="115 KV" b3="95A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="115 KV" b3="L5T95" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="115 KV" b3="L8T95" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35640</SeqNum>
    <Name>L115.Dupont-Kevlar.116</Name>
    <LastEdit Timestamp="2026-04-20T11:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPONT4" b2="115 KV" b3="11662" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEVLAR" b2="115 KV" b3="116A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEVLAR" b2="115 KV" b3="11672" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEVLAR" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEVLAR" b2="13 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35650</SeqNum>
    <Name>L115.Doom-Fshrsvll-StrtsDrft-DupontWaynesboro.117</Name>
    <LastEdit Timestamp="2024-08-19T14:11:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FISHERSV" b2="115 KV" b3="117B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BARTERBR" b2="115 KV" b3="117C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BARTERBR" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="115 KV" b3="11742" />
      <ContingencyEquipment Action="L" Type="LN" b1="FISHERSV" b2="115 KV" b3="117A" />
      <ContingencyEquipment Action="X" Type="XF" b1="FISHERSV" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FISHERSV" b2="22 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="FISHERSV" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FISHERSV" b2="22 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITKAT" b2="115 KV" b3="117T1063" />
      <ContingencyEquipment Action="L" Type="LN" b1="KITKAT" b2="115 KV" b3="KIT-STUD" />
      <ContingencyEquipment Action="L" Type="LN" b1="STUDRAFT" b2="115 KV" b3="117D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NIBCO" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="STUDRAFT" b2="115 KV" b3="SC3" />
      <ContingencyEquipment Action="X" Type="XF" b1="STUDRAFT" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STUDRAFT" b2="22 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="STUDRAFT" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STUDRAFT" b2="22 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35660</SeqNum>
    <Name>L115.PortRepublic-ElktonDP-Merck.119</Name>
    <LastEdit Timestamp="2026-06-05T08:52:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MERCK5" b2="115 KV" b3="119B" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKTONDP" b2="115 KV" b3="ELK-PRTR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELKTONDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCK5" b2="115 KV" b3="11902" />
      <ContingencyEquipment Action="X" Type="XF" b1="MERCK5" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MERCK5" b2="115 KV" b3="TX1D1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MERCK5" b2="35 KV" b3="TX1D1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MERCK5" b2="115 KV" b3="TX1D2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MERCK5" b2="35 KV" b3="TX1D2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MERCK5" b2="13 KV" b3="TX1LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="MERCK5" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MERCK5" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRTRPBLC" b2="115 KV" b3="11962" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRTRPBLC" b2="115 KV" b3="119T1089" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35670</SeqNum>
    <Name>L115.Chesapeake-Greenwich.120</Name>
    <LastEdit Timestamp="2025-04-24T14:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="115 KV" b3="12022" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHESAPKE" b2="115 KV" b3="12028" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOZIER" b2="115 KV" b3="120C" />
      <ContingencyEquipment Action="L" Type="LN" b1="THOMPSCR" b2="115 KV" b3="120B" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOZIER" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOZIER" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOZIER" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOZIER" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENWCH" b2="115 KV" b3="120A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="115 KV" b3="L1T120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="115 KV" b3="L2T120" />
      <ContingencyEquipment Action="X" Type="XF" b1="THOMPSCR" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THOMPSCR" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="THOMPSCR" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THOMPSCR" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="THOMPSCR" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THOMPSCR" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="THOMPSCR" b2="115 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THOMPSCR" b2="35 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35690</SeqNum>
    <Name>L115.ReevesAve-McLaughlin.125</Name>
    <LastEdit Timestamp="2026-04-20T11:51:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="REEVESAV" b2="115 KV" b3="125A" />
      <ContingencyEquipment Action="X" Type="XF" b1="MCLAUGH" b2="115 KV" b3="TX5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCLAUGH" b2="35 KV" b3="TX5" />
      <ContingencyEquipment Action="X" Type="XF" b1="MCLAUGH" b2="115 KV" b3="TX6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCLAUGH" b2="35 KV" b3="TX6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="115 KV" b3="12512" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="REEVESAV" b2="115 KV" b3="125T164" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35710</SeqNum>
    <Name>L115.SouthHampton-HandsomDP-Newsoms.140</Name>
    <LastEdit Timestamp="2026-04-20T11:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SHAMPTON" b2="115 KV" b3="140B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HANDSMDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWSOMS" b2="115 KV" b3="14092" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANDSMDP" b2="115 KV" b3="140C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWSOMS" b2="115 KV" b3="140T1017" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAMPTON" b2="115 KV" b3="93T140" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35720</SeqNum>
    <Name>L115.BowersHill-AlexandersCorner.144</Name>
    <LastEdit Timestamp="2026-04-22T09:54:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOWERSHL" b2="115 KV" b3="144A" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALEXANDC" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALEXANDC" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWERSHL" b2="115 KV" b3="14432" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BOWERSHL" b2="115 KV" b3="14437" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35730</SeqNum>
    <Name>L115.Clubhouse-Purdy-FieldsCrossroads-Jarratt.148</Name>
    <LastEdit Timestamp="2025-05-13T14:58:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLBHOUSE" b2="115 KV" b3="14852" />
      <ContingencyEquipment Action="L" Type="LN" b1="PURDY" b2="115 KV" b3="148A" />
      <ContingencyEquipment Action="X" Type="XF" b1="FIELDSCR" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FIELDSCR" b2="34.5 KV" b3="TX1LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIELDSCR" b2="115 KV" b3="FIE-JARR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JARRATT" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JARRATT" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JARRATT" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JARRATT" b2="115 KV" b3="TX4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PURDY" b2="115 KV" b3="69T148" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIELDSCR" b2="115 KV" b3="FIE-PURD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35740</SeqNum>
    <Name>L115.Willismount-CurdsvilleDP.149</Name>
    <LastEdit Timestamp="2026-04-22T09:54:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CURDSVDP" b2="115 KV" b3="149A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CURDSVDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLISMT" b2="115 KV" b3="14922" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WILLISMT" b2="115 KV" b3="14927" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35750</SeqNum>
    <Name>L115.ChaseCity-TwittysCreek.1012</Name>
    <LastEdit Timestamp="2026-04-22T09:54:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CENTRAL" b2="115 KV" b3="1012A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTRAL" b2="115 KV" b3="1012B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CENTRAL" b2="115 KV" b3="DRAKBRDP" />
      <ContingencyEquipment Action="X" Type="XF" b1="CENTRAL" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CENTRAL" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHASECTY" b2="115 KV" b3="101212CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWITTYCK" b2="115 KV" b3="154T1012" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TWITTYCK" b2="35 KV" b3="TWITTYSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="TWITTYCK" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TWITTYCK" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35770</SeqNum>
    <Name>L115.Acca-Hermtage-Shockoe.159</Name>
    <LastEdit Timestamp="2026-04-20T11:45:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ACCA" b2="115 KV" b3="15972" />
      <ContingencyEquipment Action="L" Type="LN" b1="ACCA" b2="115 KV" b3="159A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HERMTAGE" b2="115 KV" b3="159B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HERMTAGE" b2="34.5 KV" b3="LOAD 1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HERMTAGE" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHOCKOE" b2="115 KV" b3="20T159" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHOCKOE" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHOCKOE" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHOCKOE" b2="115 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHOCKOE" b2="35 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35780</SeqNum>
    <Name>L115.Dooms-Dupont Waynesboro.160</Name>
    <LastEdit Timestamp="2026-04-21T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="115 KV" b3="16042" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOOMS4" b2="115 KV" b3="160A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPWAYNE" b2="115 KV" b3="16052" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUPWAYNE" b2="115 KV" b3="160B" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAYNESBO" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAYNESBO" b2="22 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35790</SeqNum>
    <Name>L115.Trowbridge-Weyerhaeuser.167</Name>
    <LastEdit Timestamp="2025-01-03T14:33:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="TROWBRDG" b2="115 KV" b3="167A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="115 KV" b3="167T1020" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="115 KV" b3="167T168" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="115 KV" b3="L1T167" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEYERHSR" b2="115 KV" b3="16702" />
      <ContingencyEquipment Action="X" Type="XF" b1="WEYERHSR" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WEYERHSR" b2="14 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35800</SeqNum>
    <Name>L115.Trowbridge-Weyerhaeuser.168</Name>
    <LastEdit Timestamp="2025-01-09T11:33:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="115 KV" b3="167T168" />
      <ContingencyEquipment Action="L" Type="LN" b1="TROWBRDG" b2="115 KV" b3="168A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="115 KV" b3="25T168" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="115 KV" b3="L2T168" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEYERHSR" b2="115 KV" b3="16802" />
      <ContingencyEquipment Action="X" Type="XF" b1="WEYERHSR" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WEYERHSR" b2="14 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35810</SeqNum>
    <Name>L115.Harrisonburg-Dayton DP.170</Name>
    <LastEdit Timestamp="2026-04-21T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HARRSNBG" b2="115 KV" b3="170A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAYTONDP" b2="115 KV" b3="DAYTONDP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="115 KV" b3="17092" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35840</SeqNum>
    <Name>L138.Saltville-Meadowview-Hansonvl-ClinchRiver</Name>
    <LastEdit Timestamp="2025-12-16T12:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINCHRI" b2="138 KV" b3="CLI-HAN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANSONVL" b2="138 KV" b3="HAN-MEA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HANSONVL" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWVI" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWVI" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADOWVI" b2="138 KV" b3="MEA-SAL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MEADOWVI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEADOWVI" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWVI" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWVI" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTVILL" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35860</SeqNum>
    <Name>L138.ClinchRiver-CopperRidge-Hill-Nagel</Name>
    <LastEdit Timestamp="2026-04-21T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINCHRI" b2="138 KV" b3="CLI-COP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COPPERRI" b2="138 KV" b3="COP-HIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COPPERRI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HILL_AEP" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GATECITY" b2="69 KV" b3="GAT-HIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILL_AEP" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILL_AEP" b2="138 KV" b3="HIL-NAG1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILL_AEP" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HILL_AEP" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="138 KV" b3="K2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35870</SeqNum>
    <Name>L138.Nagel-WestKingsport</Name>
    <LastEdit Timestamp="2025-11-07T15:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="138 KV" b3="M2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NAGELAEP" b2="138 KV" b3="NAG-WKI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WKINGSPO" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WKINGSPO" b2="138 KV" b3="P2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35880</SeqNum>
    <Name>L138.Nagel-FortRobison</Name>
    <LastEdit Timestamp="2024-11-05T09:30:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FORTROBI" b2="138 KV" b3="A001H2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FORTROBI" b2="138 KV" b3="FOR-NAG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="138 KV" b3="M1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35890</SeqNum>
    <Name>L138.NBristol-IndianSp-EdensRidge-WKingsport</Name>
    <LastEdit Timestamp="2026-01-27T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDENSRID" b2="138 KV" b3="A001E5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDENSRID" b2="138 KV" b3="A001E8" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDENSRID" b2="138 KV" b3="EDE-IND1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDENSRID" b2="138 KV" b3="EDE-WKI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="INDIANSP" b2="138 KV" b3="IND-NBR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANSP" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANSP" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBRISTOL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WKINGSPO" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WKINGSPO" b2="138 KV" b3="N1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35900</SeqNum>
    <Name>L138.Amos-Curry-Milton</Name>
    <LastEdit Timestamp="2026-04-21T09:38:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="138 KV" b3="AMO-CUR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CURRY" b2="138 KV" b3="CUR-MIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CURRY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CURRY" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON2" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35910</SeqNum>
    <Name>L138.BallsGap-HashRidge-ParkHill-WestHuntington</Name>
    <LastEdit Timestamp="2026-04-21T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BALLSGAP" b2="138 KV" b3="BAL-HAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALLSGAP" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HASHRIDG" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HASHRIDG" b2="138 KV" b3="HAS-PAR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PARKHILL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHUNTING" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="PARKHILL" b2="138 KV" b3="PAR-WHU1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35920</SeqNum>
    <Name>L138.Amos-Tackett-Turner</Name>
    <LastEdit Timestamp="2026-04-21T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="138 KV" b3="AMO-TAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TACKETTC" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TACKETTC" b2="138 KV" b3="TAC-TUR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35930</SeqNum>
    <Name>L138.Amos-Turner</Name>
    <LastEdit Timestamp="2026-04-21T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="138 KV" b3="AMO-TUR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="A2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35950</SeqNum>
    <Name>L138.Amos-Lakeview-Turner</Name>
    <LastEdit Timestamp="2026-04-21T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="138 KV" b3="AMO-LAK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEVIE1" b2="138 KV" b3="LAK-TUR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAKEVIE1" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35960</SeqNum>
    <Name>L138.Chemical-UnionCarbide8-Turner</Name>
    <LastEdit Timestamp="2026-04-21T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="138 KV" b3="AC" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHEMICAL" b2="138 KV" b3="CHE-UNI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TURNER" b2="138 KV" b3="TUR-UNI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIONCA8" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="UNIONCA8" b2="138 KV" b3="UNI-UNI1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35980</SeqNum>
    <Name>L138.Abingdon-ClinchRiver</Name>
    <LastEdit Timestamp="2024-10-24T14:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ABINGDON" b2="138 KV" b3="ABI-CLI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ABINGDON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>35990</SeqNum>
    <Name>L138.Atkins-RuralRetreat-MountAiry-Wythe</Name>
    <LastEdit Timestamp="2026-04-21T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ATKINS" b2="138 KV" b3="ATK-RUR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATKINS" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ATKINS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTAIRY2" b2="138 KV" b3="MTA-WYT1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTAIRY2" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="RURALRET" b2="138 KV" b3="RUR-MTA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RURALRET" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYTHE" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36000</SeqNum>
    <Name>L138.ClinchRiver-Fremont</Name>
    <LastEdit Timestamp="2026-04-23T08:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINCHRI" b2="138 KV" b3="CLI-FRE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONT" b2="138 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36010</SeqNum>
    <Name>L138.BeaverCreek-Dorton</Name>
    <LastEdit Timestamp="2026-04-23T08:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVERCR" b2="138 KV" b3="BEA-DOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DORTON" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36030</SeqNum>
    <Name>L138.ClinchRvr-Clinchfld-Fletcher-Skggs-GardenCr</Name>
    <LastEdit Timestamp="2024-05-14T09:20:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CLINCHFI" b2="138 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHFI" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINCHFI" b2="138 KV" b3="CLI-CLI2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINCHFI" b2="138 KV" b3="CLI-FLE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHFI" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="F2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLETCHER" b2="138 KV" b3="FLE-SKE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLETCHER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GARDENCR" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARDENCR" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARDENCR" b2="138 KV" b3="GAR-HAL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARDENCR" b2="138 KV" b3="GAR-SKE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARDENCR" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="X" Type="XF" b1="GARDENCR" b2="138 KV" b3="XF-T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SKEGGSBR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="X" Type="XF" b1="SKEGGSBR" b2="138 KV" b3="XF-T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36040</SeqNum>
    <Name>L138.Fremont-BeaverCreek</Name>
    <LastEdit Timestamp="2026-04-23T08:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVERCR" b2="138 KV" b3="BEA-FRE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONT" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36050</SeqNum>
    <Name>L138.MorelandDrive-Riverport</Name>
    <LastEdit Timestamp="2025-05-02T13:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORELAND" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERPRT" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERPRT" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORELAND" b2="138 KV" b3="MOR-RIVR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36060</SeqNum>
    <Name>L138.Concord-CountrySide-Charger</Name>
    <LastEdit Timestamp="2024-12-31T13:34:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARGER" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARGER" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONCORD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHARGER" b2="138 KV" b3="CHA-COU" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONCORD" b2="138 KV" b3="CON-COU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COUNTRYS" b2="138 KV" b3="EARTHMLF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COUNTRYS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36070</SeqNum>
    <Name>L138.Cloverdale-HuntingtonCourt</Name>
    <LastEdit Timestamp="2026-04-23T08:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVERD2" b2="138 KV" b3="CLO-HUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTINCT" b2="138 KV" b3="T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36080</SeqNum>
    <Name>L138.Cloverdale-Bonsack-Vinton-Roanoke</Name>
    <LastEdit Timestamp="2026-04-23T08:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BONSACK" b2="138 KV" b3="BON-CLO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BONSACK" b2="138 KV" b3="BON-VIN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BONSACK" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROANOKE" b2="138 KV" b3="ROA-VIN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VINTON" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VINTON" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36090</SeqNum>
    <Name>L138.Cloverdale-LakeForest-Ivyhill-Coffee-Reusens</Name>
    <LastEdit Timestamp="2025-07-24T16:26:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CENTRVIL" b2="138 KV" b3="CEN-IVY" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTRVIL" b2="138 KV" b3="CEN-LAK" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVERD2" b2="138 KV" b3="CLO-LAK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="COFFEE" b2="138 KV" b3="COF-IVY" />
      <ContingencyEquipment Action="L" Type="LN" b1="COFFEE" b2="138 KV" b3="COF-REU1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COFFEE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IVYHILL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVYHILL" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LKFOREST" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REUSENS" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36120</SeqNum>
    <Name>L138.Bradley-Grandview</Name>
    <LastEdit Timestamp="2026-04-23T08:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADLEY" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADLEY" b2="138 KV" b3="BRA-GRA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDVAP" b2="138 KV" b3="R" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36130</SeqNum>
    <Name>L138.Bradley-Poleyard-NBeckley-JehuBranch</Name>
    <LastEdit Timestamp="2026-04-23T08:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADLEY" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBECKLEY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NBECKLEY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NBECKLEY" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="POLEYARD" b2="138 KV" b3="BRA-POL" />
      <ContingencyEquipment Action="L" Type="LN" b1="POLEYARD" b2="138 KV" b3="NBE-POL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POLEYARD" b2="138 KV" b3="POLEYARD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36140</SeqNum>
    <Name>L138.Bradley-Dameron</Name>
    <LastEdit Timestamp="2025-12-17T11:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADLEY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADLEY" b2="138 KV" b3="BRA-DAM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADLEY" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAMERON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAMERON" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36160</SeqNum>
    <Name>L138.Reusens-Centerville-Moseley</Name>
    <LastEdit Timestamp="2024-09-18T09:22:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CENTRVIL" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="CENTRVIL" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTRVIL" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CENTRVIL" b2="69 KV" b3="BEDFORD" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTRVIL" b2="138 KV" b3="CEN-MOS1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTRVIL" b2="138 KV" b3="CEN-REU1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CENTRVIL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSELEY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REUSENS" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36170</SeqNum>
    <Name>L138.Boxwood-Clifford</Name>
    <LastEdit Timestamp="2026-06-01T11:57:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOXWOOD" b2="138 KV" b3="BOX-CLI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOXWOOD" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOXWOOD" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFFORD" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36180</SeqNum>
    <Name>L138.Reusens-Monel-Gomingo-JoshuaFalls</Name>
    <LastEdit Timestamp="2025-09-02T10:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GOMINGO" b2="138 KV" b3="GOM-JOS1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOMINGO" b2="138 KV" b3="GOM-MON1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOMINGO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOSHUAF2" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOSHUAF2" b2="138 KV" b3="J1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONEL" b2="138 KV" b3="MON-REU1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONEL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REUSENS" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36190</SeqNum>
    <Name>L138.Reusens-Boonsboro-Forest-NewLondon</Name>
    <LastEdit Timestamp="2026-01-28T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOONSBO2" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOONSBO2" b2="138 KV" b3="BOO-FOR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOREST2" b2="138 KV" b3="FOR-NEW1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FOREST2" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FOREST2" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLONDO" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWLONDO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLONDO" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOONSBO2" b2="138 KV" b3="BOO-REU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REUSENS" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36210</SeqNum>
    <Name>L138.Roanoke-Moseley</Name>
    <LastEdit Timestamp="2025-05-12T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSELEY" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOSELEY" b2="138 KV" b3="MOS-ROA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36220</SeqNum>
    <Name>L138.Roanoke-Sunscape-CaveSpring-Hancock</Name>
    <LastEdit Timestamp="2024-11-19T11:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CAVESPRI" b2="138 KV" b3="CAV-HAN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAVESPRI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAVESPRI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CAVESPRI" b2="138 KV" b3="X2DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAVESPRI" b2="138 KV" b3="CAV-SUN" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROANOKE" b2="138 KV" b3="ROA-SUN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNSCAPE" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36230</SeqNum>
    <Name>L138.Roanoke-Clearbrook-BentMt-MattFunk</Name>
    <LastEdit Timestamp="2026-04-24T08:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BENTMOUN" b2="138 KV" b3="BEN-CLE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENTMOUN" b2="138 KV" b3="BEN-MAT1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENTMOUN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENTMOUN" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLEARBRO" b2="138 KV" b3="CLE-ROA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLEARBRO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36240</SeqNum>
    <Name>L138.GlenLyn-HazelHollow-Claytor</Name>
    <LastEdit Timestamp="2026-04-23T08:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYTOR" b2="138 KV" b3="CLA-HAZ1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENLYN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZELHOL" b2="138 KV" b3="138" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAZELHOL" b2="138 KV" b3="HAZ-GLE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAZELHOL" b2="138 KV" b3="HAZ-ING1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INGLESST" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36250</SeqNum>
    <Name>L138.GlenLyn-Progress</Name>
    <LastEdit Timestamp="2026-04-24T08:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENLYN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PROGRESS" b2="138 KV" b3="G CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENLYN" b2="138 KV" b3="GLE1-PRO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36260</SeqNum>
    <Name>L138.GlenLyn-PetersMtn-Celanese</Name>
    <LastEdit Timestamp="2026-04-24T08:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CELANESE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CELANESE" b2="138 KV" b3="CEL-PET1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENLYN" b2="138 KV" b3="GLE-PET1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENLYN" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PETERSMO" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36280</SeqNum>
    <Name>L138.GlenLyn-Hinton</Name>
    <LastEdit Timestamp="2026-04-23T08:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENLYN" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="HINTON" b2="138 KV" b3="HIN-GLE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36290</SeqNum>
    <Name>L138.GlenLyn-Morgans-Claytor</Name>
    <LastEdit Timestamp="2026-04-23T08:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYTOR" b2="138 KV" b3="CLA-MOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENLYN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORGANSC" b2="138 KV" b3="MOR-GLE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MORGANSC" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36300</SeqNum>
    <Name>L138.MattFunk-Shwsvll-FallingBranch</Name>
    <LastEdit Timestamp="2026-04-24T08:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FALLINGB" b2="138 KV" b3="FAL-SHA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLINGB" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MATTFUN2" b2="138 KV" b3="MAT-SHA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHAWSVIL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36310</SeqNum>
    <Name>L138.Hancock-MattFunk.1</Name>
    <LastEdit Timestamp="2026-01-09T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANCOCK" b2="138 KV" b3="HAN-MAT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="K1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36320</SeqNum>
    <Name>L138.Claytor-SouthChristiansburg-TechDrive</Name>
    <LastEdit Timestamp="2025-10-15T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYTOR" b2="138 KV" b3="CLA-SCH1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHRISTI" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCHRISTI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCHRISTI" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TECHDRIV" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCHRISTI" b2="138 KV" b3="SOU-TEC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TECHDRIV" b2="138 KV" b3="XT1L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36330</SeqNum>
    <Name>L138.Claytor-AlumRdg-Floyd-Philpott-WestBassett</Name>
    <LastEdit Timestamp="2025-11-17T12:12:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALUMRIDG" b2="138 KV" b3="ALU-CLA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALUMRIDG" b2="138 KV" b3="ALU-FLO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALUMRIDG" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLOYD" b2="138 KV" b3="2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLOYD" b2="69 KV" b3="2-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLOYD" b2="34.5 KV" b3="2-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLOYD" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLOYD" b2="138 KV" b3="FLO-PHI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLOYD" b2="138 KV" b3="T-4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLOYD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLOYD" b2="34.5 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PHILPOTT" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PHILPOTT" b2="138 KV" b3="UNITS1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBASSETT" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="WBASSETT" b2="138 KV" b3="WBA-PHI1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36340</SeqNum>
    <Name>L138.Hancock-RoanokeElectricSteel</Name>
    <LastEdit Timestamp="2026-01-09T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK" b2="138 KV" b3="AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK" b2="138 KV" b3="AC" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANCOCK" b2="138 KV" b3="HAN-ROA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROANELST" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROANELST" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROANELST" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36350</SeqNum>
    <Name>L138.BigSandy-Busseyville-Thelma</Name>
    <LastEdit Timestamp="2026-04-24T08:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIGSANDY" b2="138 KV" b3="BIG-BUS1" />
      <ContingencyEquipment Action="S" Type="SD" b1="BIGSANDY" b2="138 KV" b3="BIGSANDY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUSSEYVI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUSSEYVI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="X" Type="XF" b1="THELMA" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="L" Type="LN" b1="THELMA" b2="138 KV" b3="THE-BUS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36360</SeqNum>
    <Name>L138.BigSandy-Inez</Name>
    <LastEdit Timestamp="2026-04-23T08:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INEZ" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INEZ" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="INEZ" b2="138 KV" b3="INE-BIG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36370</SeqNum>
    <Name>L138.BigSandy-Grangston</Name>
    <LastEdit Timestamp="2026-04-23T08:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIGSANDY" b2="138 KV" b3="BIG-GRA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANGSTO" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36380</SeqNum>
    <Name>L138.TriState-Hubbards-BigSandy</Name>
    <LastEdit Timestamp="2025-03-14T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUBBARDS" b2="138 KV" b3="HUB-BIG1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUBBARDS" b2="138 KV" b3="HUB-TRI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUBBARDS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="D1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36420</SeqNum>
    <Name>L138.Inez-WolfCrk-Lovely-Newsome-Dingess-Mud-Logan</Name>
    <LastEdit Timestamp="2026-04-24T08:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DINGESS" b2="138 KV" b3="DIN-MUD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DINGESS" b2="138 KV" b3="DIN-NEW1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DINGESS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INEZ" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INEZ" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="INEZ" b2="138 KV" b3="INE-WOL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGAN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOGAN" b2="138 KV" b3="LOG-MUD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOVELY" b2="138 KV" b3="LOV-NEW1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOVELY" b2="138 KV" b3="LOV-WOL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOVELY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARROWBO" b2="138 KV" b3="MAR-NEW1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARROWBO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MUDFORK" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36430</SeqNum>
    <Name>L138.Inez-JohnsCreek</Name>
    <LastEdit Timestamp="2025-10-29T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INEZ" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INEZ" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="INEZ" b2="138 KV" b3="INE-JOHN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSCRE" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36440</SeqNum>
    <Name>L138.KanawhaRiver-Rensford-PointLick-Coco</Name>
    <LastEdit Timestamp="2024-09-23T13:06:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COCO" b2="138 KV" b3="A001G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COCO" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="KANAWHAR" b2="138 KV" b3="KAN-REN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COCO" b2="138 KV" b3="COC-POI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POINTLIC" b2="138 KV" b3="PATRIOT" />
      <ContingencyEquipment Action="L" Type="LN" b1="POINTLIC" b2="138 KV" b3="POI-REN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RENSFORD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36450</SeqNum>
    <Name>L138.KanawhaRiver-Alloy</Name>
    <LastEdit Timestamp="2026-04-24T08:38:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="ALLOY" b2="138 KV" b3="CONV" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ALLOY" b2="138 KV" b3="HYD1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ALLOY" b2="138 KV" b3="HYD2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLOY" b2="138 KV" b3="LT21" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLOY" b2="138 KV" b3="LT31" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLOY" b2="138 KV" b3="ALL-KAN1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KANAWHAR" b2="138 KV" b3="BYPS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="138 KV" b3="N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36460</SeqNum>
    <Name>L138.KanawhaRiver-Kincaida-Bradley</Name>
    <LastEdit Timestamp="2024-11-13T08:45:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADLEY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADLEY" b2="138 KV" b3="BRA-KIN1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KANAWHAR" b2="138 KV" b3="BYPS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="KANAWHAR" b2="138 KV" b3="KAN-KIN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINCAIDA" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36470</SeqNum>
    <Name>L138.KanawhaRiver-PaxBranch-SandBranch-Bradley</Name>
    <LastEdit Timestamp="2025-12-12T10:41:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRADLEY" b2="138 KV" b3="BRA-SAND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADLEY" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="KANAWHAR" b2="138 KV" b3="KAN-PXBR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PXBRANCH" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PXBRANCH" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PXBRANCH" b2="138 KV" b3="PXB-SAND" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SANDBRAN" b2="138 KV" b3="REPUBLIC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36480</SeqNum>
    <Name>L138.Sundial-Shumate-Bim-Wharton</Name>
    <LastEdit Timestamp="2025-11-10T11:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BIM" b2="138 KV" b3="BIM-WHA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BIM" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHUMATE" b2="138 KV" b3="PROGRESS" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHUMATE" b2="138 KV" b3="SHUM-WHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNDIAL" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUNDIAL" b2="138 KV" b3="SHU-SUN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHARTON" b2="138 KV" b3="T1T2T3" />
      <ContingencyEquipment Action="L" Type="LN" b1="WHARTON" b2="138 KV" b3="WHA-WHA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36490</SeqNum>
    <Name>L138.KanawhaRiver-Dawes-CoalFork-10M-Sundial.1</Name>
    <LastEdit Timestamp="2026-04-24T08:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COALFORK" b2="138 KV" b3="COA-DAW" />
      <ContingencyEquipment Action="L" Type="LN" b1="COALFORK" b2="138 KV" b3="COA-TEN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COALFORK" b2="138 KV" b3="MSF" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAWES" b2="138 KV" b3="DAW-KAN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAWES" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDWARRI" b2="138 KV" b3="RED-TEN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REDWARRI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNDIAL" b2="138 KV" b3="M CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="TENMILE" b2="138 KV" b3="TEN-SUN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36500</SeqNum>
    <Name>L138.KanawhaRiver-CabinCreek1</Name>
    <LastEdit Timestamp="2026-04-24T08:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINCRE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CABINCRE" b2="138 KV" b3="CAB-KAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36510</SeqNum>
    <Name>L138.KanawhaRiver-CabinCreek2</Name>
    <LastEdit Timestamp="2026-04-27T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINCRE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CABINCRE" b2="138 KV" b3="CAB-KAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36530</SeqNum>
    <Name>138/69/34.Corey.T1</Name>
    <LastEdit Timestamp="2026-04-24T08:28:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="COREY" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="COREY" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="COREY" b2="34 KV" b3="1-T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COREY" b2="34 KV" b3="1T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COREY" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COREY" b2="138 KV" b3="J1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COREY" b2="69 KV" b3="XB1L CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36540</SeqNum>
    <Name>L138.Rhodes-MiltonSW-Corwin</Name>
    <LastEdit Timestamp="2024-10-30T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORWIN" b2="138 KV" b3="COR-MIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CORWIN" b2="138 KV" b3="GM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORWIN" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CORWIN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILTONSW" b2="138 KV" b3="T1 LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RHODS" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RHODS" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILTONSW" b2="138 KV" b3="MIL-RHO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36560</SeqNum>
    <Name>L138.Lemaster-PostStRd-Sunday-SpencerRd-Crksville</Name>
    <LastEdit Timestamp="2025-05-16T13:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROOKSVI" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROOKSVI" b2="138 KV" b3="CRO-SPE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMASTER" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMASTER" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEMASTER" b2="138 KV" b3="LEM-POS" />
      <ContingencyEquipment Action="L" Type="LN" b1="POSTSTRD" b2="138 KV" b3="POS-STR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPENCERD" b2="138 KV" b3="BUCKCOAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STROUDSR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STROUDSR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STROUDSR" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="POSTSTRD" b2="138 KV" b3="POS-SUN" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPENCERD" b2="138 KV" b3="SPE-SUN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNDAY" b2="138 KV" b3="TRIMBLE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36580</SeqNum>
    <Name>L138.Lemaster-GoodHope-Endor-Lockbourne</Name>
    <LastEdit Timestamp="2026-06-05T09:21:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ENDOR" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENDOR" b2="138 KV" b3="END-GOOD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOODHOPE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMASTER" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMASTER" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOODHOPE" b2="138 KV" b3="GOO-LEM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKBOUR" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKBOUR" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENDOR" b2="138 KV" b3="END-LOCK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36590</SeqNum>
    <Name>L138.Tuscany-Neville-SciotoTrail-DupontCS</Name>
    <LastEdit Timestamp="2025-06-26T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DUPONTCS" b2="138 KV" b3="DUP-NEV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUPONTCS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEVILLE2" b2="138 KV" b3="NEV-SCI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCIOTOTR" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUSCANY" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUSCANY" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEVILLE2" b2="138 KV" b3="NEV-TUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36600</SeqNum>
    <Name>L138.SciotoTrail-Scippo</Name>
    <LastEdit Timestamp="2026-04-24T08:40:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="DUPONTCS" b2="138 KV" b3="BT" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUPONTCS" b2="138 KV" b3="DUP-SCI2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUPONTCS" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCIOTOTR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCIOTOTR" b2="138 KV" b3="SCI-SCI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCIPPO" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36610</SeqNum>
    <Name>L138.Dexter-Meigs-Rutland</Name>
    <LastEdit Timestamp="2025-01-31T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEXTER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEXTER" b2="138 KV" b3="DEX-ME31" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MEIGS31" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MEIGS31" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUTLAND" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUTLAND" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEIGS31" b2="138 KV" b3="MEI-RUTL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RUTLAND" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36620</SeqNum>
    <Name>L138.Circleville-Scippo</Name>
    <LastEdit Timestamp="2026-04-27T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CIRCLEVI" b2="138 KV" b3="AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CIRCLEVI" b2="138 KV" b3="AC" />
      <ContingencyEquipment Action="L" Type="LN" b1="CIRCLEVI" b2="138 KV" b3="CIR-SCI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCIPPO" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36630</SeqNum>
    <Name>L138.Circleville-Harrison</Name>
    <LastEdit Timestamp="2026-04-24T08:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CIRCLEVI" b2="138 KV" b3="AF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CIRCLEVI" b2="138 KV" b3="AG" />
      <ContingencyEquipment Action="L" Type="LN" b1="CIRCLEVI" b2="138 KV" b3="CIR-HAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISCS" b2="138 KV" b3="6C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISCS" b2="138 KV" b3="6W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36650</SeqNum>
    <Name>L138.OhioCentral-Frazeyburg-Reform-NorthNewark</Name>
    <LastEdit Timestamp="2025-09-22T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FRAZEYB" b2="138 KV" b3="FRA-OHI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRAZEYB" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NNEWARK" b2="138 KV" b3="H001A8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="REFORM" b2="138 KV" b3="FRA-REF" />
      <ContingencyEquipment Action="L" Type="LN" b1="REFORM" b2="138 KV" b3="NNE-REF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REFORM" b2="138 KV" b3="REFORM1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REFORM" b2="138 KV" b3="REFORM2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36660</SeqNum>
    <Name>L138.NorthNewark-Heath</Name>
    <LastEdit Timestamp="2026-04-27T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HEATH" b2="138 KV" b3="HEA-NNE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATH" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NNEWARK" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36670</SeqNum>
    <Name>L138.NorthNewark-SharpRoad</Name>
    <LastEdit Timestamp="2026-04-27T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NNEWARK" b2="138 KV" b3="I" />
      <ContingencyEquipment Action="L" Type="LN" b1="NNEWARK" b2="138 KV" b3="NNE-SHA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARPROA" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36690</SeqNum>
    <Name>L138.Bixby-ThreeCreeks-GrovesRoad</Name>
    <LastEdit Timestamp="2024-11-19T17:41:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="138 KV" b3="119" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="138 KV" b3="120" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIXBY" b2="138 KV" b3="BIX-THRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GROVES" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GROVES" b2="138 KV" b3="GRO-THRE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THREECRK" b2="138 KV" b3="GRIFFINW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36700</SeqNum>
    <Name>L138.Bixby-LSII</Name>
    <LastEdit Timestamp="2026-04-24T08:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="138 KV" b3="117" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="138 KV" b3="118" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIXBY" b2="138 KV" b3="BIX-LSI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LSII" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LSII" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36710</SeqNum>
    <Name>L138.Bixby-GrovesRoad</Name>
    <LastEdit Timestamp="2025-04-23T11:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="138 KV" b3="116" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="138 KV" b3="117" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIXBY" b2="138 KV" b3="BIX-GRO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BIXBY" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GROVES" b2="138 KV" b3="4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36720</SeqNum>
    <Name>L138.Zuber-BeattyRoad</Name>
    <LastEdit Timestamp="2025-01-30T15:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="3C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="3E" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEATTY" b2="138 KV" b3="BEA-ZUB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZUBER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZUBER" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36730</SeqNum>
    <Name>L138.Harrison-Obetz-Marion</Name>
    <LastEdit Timestamp="2025-04-24T11:00:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISCS" b2="138 KV" b3="2C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISCS" b2="138 KV" b3="2E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="H015A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="H015A5" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRISCS" b2="138 KV" b3="HAR-OBE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="OBETZ" b2="138 KV" b3="OBE-MAR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OBETZ" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36740</SeqNum>
    <Name>L138.Bolton-Hall</Name>
    <LastEdit Timestamp="2026-04-24T08:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOLTON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOLTON" b2="138 KV" b3="BOL-HAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOLTON" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HALL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HALL" b2="138 KV" b3="TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HALL" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36750</SeqNum>
    <Name>L138.WestMtVernon-Academia</Name>
    <LastEdit Timestamp="2025-08-29T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ACADEMIA" b2="138 KV" b3="ACA-WMT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ACADEMIA" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMTVERNO" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36760</SeqNum>
    <Name>L138.GrovesRoad-Bexley</Name>
    <LastEdit Timestamp="2025-04-23T16:09:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEXLEY" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEXLEY" b2="138 KV" b3="104" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEXLEY" b2="138 KV" b3="BEX-GRO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GROVES" b2="138 KV" b3="9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36780</SeqNum>
    <Name>L138.Astor-EastBroadSt</Name>
    <LastEdit Timestamp="2026-04-27T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTOR" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASTOR" b2="138 KV" b3="AST-EBR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ASTOR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBROAD" b2="138 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36790</SeqNum>
    <Name>L138.Skenton-WildCreek-LaRue</Name>
    <LastEdit Timestamp="2025-08-07T11:45:38" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LARUE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARUE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="LARUE" b2="138 KV" b3="LAR-WILD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKENTON" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="SKENTON" b2="138 KV" b3="SKE-WIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILDCREE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36800</SeqNum>
    <Name>L138.Vine-Hess</Name>
    <LastEdit Timestamp="2026-04-27T09:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HESS" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="L" Type="LN" b1="HESS" b2="138 KV" b3="HES-VIN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="105" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36820</SeqNum>
    <Name>L138.FifthAvenue-Hess</Name>
    <LastEdit Timestamp="2026-02-06T12:17:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FIFTHAVE" b2="138 KV" b3="FIF-HES1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIFTHAVE" b2="138 KV" b3="H010Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIFTHAVE" b2="138 KV" b3="H010Z5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HESS" b2="138 KV" b3="3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36840</SeqNum>
    <Name>L138.Roberts-Trabue</Name>
    <LastEdit Timestamp="2025-07-07T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="G2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROBERTS2" b2="138 KV" b3="ROB-TRA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRABUE" b2="138 KV" b3="P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36850</SeqNum>
    <Name>L138.Hess-OSU</Name>
    <LastEdit Timestamp="2026-04-27T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HESS" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HESS" b2="138 KV" b3="HES-OSU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSU" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OSU" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36860</SeqNum>
    <Name>L138.Stelzer-Mifflin MOAB</Name>
    <LastEdit Timestamp="2026-04-27T09:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIFFLIN" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIFFLIN" b2="138 KV" b3="MIF-STE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIFFLIN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STELZER" b2="138 KV" b3="W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36870</SeqNum>
    <Name>L138.StClair-Mifflin</Name>
    <LastEdit Timestamp="2026-04-27T09:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIFFLIN" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIFFLIN" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIFFLIN" b2="138 KV" b3="MIF-STC1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36880</SeqNum>
    <Name>L138.Clinton-OSU</Name>
    <LastEdit Timestamp="2026-04-27T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLINTOCS" b2="138 KV" b3="CLI-OSU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTOCS" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTOCS" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="S" Type="SD" b1="CLINTOCS" b2="138 KV" b3="SERREAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSU" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OSU" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36890</SeqNum>
    <Name>L138.Clinton-Karl</Name>
    <LastEdit Timestamp="2024-11-13T12:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTOCS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTOCS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINTOCS" b2="138 KV" b3="CLI-KAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KARL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KARL" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36900</SeqNum>
    <Name>L138.Clinton-StClair</Name>
    <LastEdit Timestamp="2026-04-27T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLINTOCS" b2="138 KV" b3="CLI-STC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTOCS" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTOCS" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="S" Type="SD" b1="STCLAIR2" b2="138 KV" b3="STCLAIR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36910</SeqNum>
    <Name>L138.LSII-Marion</Name>
    <LastEdit Timestamp="2025-02-18T08:27:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LSII" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="LSII" b2="138 KV" b3="LSI-MAR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LSII" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="H015A8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="H015B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36940</SeqNum>
    <Name>L138.Kirk-EBroadSt</Name>
    <LastEdit Timestamp="2025-01-21T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBROAD" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="L" Type="LN" b1="EBROAD" b2="138 KV" b3="EBR-KIR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="138 KV" b3="H2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36950</SeqNum>
    <Name>L138.Kirk-WestHebron</Name>
    <LastEdit Timestamp="2025-01-03T14:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="138 KV" b3="K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEBRON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="WHEBRON" b2="138 KV" b3="WHE-KIR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36960</SeqNum>
    <Name>L138.Blacklick-Gahanna</Name>
    <LastEdit Timestamp="2026-04-24T08:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKLIC" b2="138 KV" b3="BLA-GAH1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BLACKLIC" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="116" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="117" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36970</SeqNum>
    <Name>L138.EastBroadSt-Poth</Name>
    <LastEdit Timestamp="2026-05-08T14:58:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBROAD" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="EBROAD" b2="138 KV" b3="EBR-POTH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBROAD" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTH" b2="138 KV" b3="H010X2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTH" b2="138 KV" b3="H010X5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36980</SeqNum>
    <Name>L138.Yearling-Bexley</Name>
    <LastEdit Timestamp="2026-05-26T09:31:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEXLEY" b2="138 KV" b3="105" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEXLEY" b2="138 KV" b3="BEX-YEA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEXLEY" b2="138 KV" b3="H023G5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YEARLING" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="YEARLING" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>36990</SeqNum>
    <Name>L138.Mound-StClair</Name>
    <LastEdit Timestamp="2026-04-27T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUND" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUND" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUND" b2="138 KV" b3="MOU-STC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MOUND" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="S" Type="SD" b1="STCLAIR2" b2="138 KV" b3="_STCLAIR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37000</SeqNum>
    <Name>L138.StClair-Bexley</Name>
    <LastEdit Timestamp="2026-04-27T09:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEXLEY" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEXLEY" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEXLEY" b2="138 KV" b3="BEX-STC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37010</SeqNum>
    <Name>L138.Italian-Vine</Name>
    <LastEdit Timestamp="2026-04-27T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ITALIANV" b2="138 KV" b3="10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ITALIANV" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="L" Type="LN" b1="ITALIANV" b2="138 KV" b3="ITA-VIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="108" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37020</SeqNum>
    <Name>L138.StClair-Italian</Name>
    <LastEdit Timestamp="2026-04-27T09:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ITALIANV" b2="138 KV" b3="10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ITALIANV" b2="138 KV" b3="9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="ITALIANV" b2="138 KV" b3="ITA-STC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37030</SeqNum>
    <Name>L138.Vine-GaySt</Name>
    <LastEdit Timestamp="2025-08-29T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAY" b2="138 KV" b3="104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAY" b2="138 KV" b3="105" />
      <ContingencyEquipment Action="L" Type="LN" b1="GAY" b2="138 KV" b3="GAY-VIN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="S" Type="SD" b1="VINE" b2="138 KV" b3="REAC102" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37040</SeqNum>
    <Name>L138.BethelRd-Linworth</Name>
    <LastEdit Timestamp="2025-05-19T15:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BETHEL2" b2="138 KV" b3="BET-LIN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHEL2" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHEL2" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWORTH" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINWORTH" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37060</SeqNum>
    <Name>L138.HapCremean-Morse</Name>
    <LastEdit Timestamp="2025-11-24T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAPCREME" b2="138 KV" b3="14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAPCREME" b2="138 KV" b3="15" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAPCREME" b2="138 KV" b3="HAP-MOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37080</SeqNum>
    <Name>L138.Morse-Blendon</Name>
    <LastEdit Timestamp="2025-05-05T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLENDON" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLENDON" b2="138 KV" b3="BLE-MOR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLENDON" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37090</SeqNum>
    <Name>L138.Genoa-Westar</Name>
    <LastEdit Timestamp="2026-04-27T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GENOA" b2="138 KV" b3="101N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GENOA" b2="138 KV" b3="101S" />
      <ContingencyEquipment Action="L" Type="LN" b1="GENOA" b2="138 KV" b3="GEN-WEST" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GENOA" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTAR" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37100</SeqNum>
    <Name>L138.Corridor-Genoa</Name>
    <LastEdit Timestamp="2026-04-27T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="106C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="106S" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORRIDOR" b2="138 KV" b3="COR-GEN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GENOA" b2="138 KV" b3="101S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GENOA" b2="138 KV" b3="102S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GENOA" b2="138 KV" b3="AA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GENOA" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GENOA" b2="138 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37110</SeqNum>
    <Name>L138.Delaware-CurveRoad-BerryWood</Name>
    <LastEdit Timestamp="2026-04-28T08:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERRYWOD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERRYWOD" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERRYWOD" b2="138 KV" b3="BER-CUR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELAWARE" b2="138 KV" b3="DEL-CUR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CURVERD" b2="138 KV" b3="T1 LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELAWARE" b2="138 KV" b3="101" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37120</SeqNum>
    <Name>L138.Berkshire-Sunbury-Trent</Name>
    <LastEdit Timestamp="2026-04-28T08:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BERKSHI2" b2="138 KV" b3="BER-SUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKSHI2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUNBURY2" b2="138 KV" b3="SUN-TRE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNBURY2" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENT" b2="138 KV" b3="102N" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="TRENT" b2="138 KV" b3="CAP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRENT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRENT" b2="138 KV" b3="TRENTBS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37140</SeqNum>
    <Name>L138.Crooksville-SLancaster</Name>
    <LastEdit Timestamp="2026-04-28T08:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CROOKSVI" b2="138 KV" b3="CRO-SLA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROOKSVI" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLANCAST" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SLANCAST" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37150</SeqNum>
    <Name>L138.Natrium-Switzer-Herlan</Name>
    <LastEdit Timestamp="2024-11-05T14:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HERLAN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERLAN" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HERLAN" b2="138 KV" b3="HER-SWI" />
      <ContingencyEquipment Action="L" Type="LN" b1="NATRIUM2" b2="138 KV" b3="NAT-SWI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWITZER" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37160</SeqNum>
    <Name>L138.Newcomerstown-Hillview-WNPhiladelphia</Name>
    <LastEdit Timestamp="2025-05-23T14:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="HILLVIEW" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLVIEW" b2="138 KV" b3="HIL-NEW1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILLVIEW" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCOMER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WNEWPHIL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WNEWPHIL" b2="138 KV" b3="CAPAA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WNEWPHIL" b2="69 KV" b3="S" />
      <ContingencyEquipment Action="X" Type="XF" b1="WNEWPHIL" b2="138 KV" b3="T2_XF" />
      <ContingencyEquipment Action="L" Type="LN" b1="WNEWPHIL" b2="138 KV" b3="WNE-HIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WNEWPHIL" b2="138 KV" b3="X4_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37170</SeqNum>
    <Name>L138.Newcomerstown-SCoshoctan</Name>
    <LastEdit Timestamp="2024-03-28T16:08:00" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCOMER" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOSHOCT" b2="138 KV" b3="I" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWCOMER" b2="138 KV" b3="NEW-SCO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCOSHOCT" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37180</SeqNum>
    <Name>L138.Newcomerstown-WCambridge</Name>
    <LastEdit Timestamp="2026-04-29T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCOMER" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWCOMER" b2="138 KV" b3="NEW-WCA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCAMBRI2" b2="138 KV" b3="B CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37190</SeqNum>
    <Name>L138.EastWooster-Wooster</Name>
    <LastEdit Timestamp="2026-04-28T08:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EWOOSTER" b2="138 KV" b3="EWO-WOO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWOOSTER" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOOSTER" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37200</SeqNum>
    <Name>L138.Wagenhals-Republic.1</Name>
    <LastEdit Timestamp="2026-04-29T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REPUBLIC" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="L" Type="LN" b1="REPUBLIC" b2="138 KV" b3="REP-WAG1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REPUBLIC" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37210</SeqNum>
    <Name>L138.Wagenhals-Republic.2</Name>
    <LastEdit Timestamp="2026-04-29T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REPUBLIC" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="L" Type="LN" b1="REPUBLIC" b2="138 KV" b3="REP-WAG2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REPUBLIC" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37220</SeqNum>
    <Name>L138.Madison-Meadow-Pendleton</Name>
    <LastEdit Timestamp="2025-01-16T15:53:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="MADISON" b2="138 KV" b3="MAD-MEA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOW" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADOW" b2="138 KV" b3="MEA-PEN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENDLETO" b2="138 KV" b3="N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37230</SeqNum>
    <Name>L138.Pendleton-FallCreek</Name>
    <LastEdit Timestamp="2026-04-29T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLCREE" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLCREE" b2="138 KV" b3="F1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FALLCREE" b2="138 KV" b3="FAL-PEN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENDLETO" b2="138 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37250</SeqNum>
    <Name>L138.CollegeCorner-Richmond</Name>
    <LastEdit Timestamp="2025-08-14T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLLEGEC" b2="138 KV" b3="COL-RIC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLEGEC" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLEGEC" b2="138 KV" b3="K1" />
      <ContingencyEquipment Action="X" Type="XF" b1="RICHMOND" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHMOND" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHMOND" b2="69 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37280</SeqNum>
    <Name>L138.FallCreek-Delcoremy</Name>
    <LastEdit Timestamp="2026-04-28T08:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DELCORM5" b2="138 KV" b3="DEL-FAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELCORM5" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DELCORM5" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLCREE" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLCREE" b2="138 KV" b3="F2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37290</SeqNum>
    <Name>L138.Strawton-PipeCreek-DeerCreek</Name>
    <LastEdit Timestamp="2025-12-01T13:46:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCREE" b2="138 KV" b3="AL" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEERCREE" b2="138 KV" b3="DEE-PIPE" />
      <ContingencyEquipment Action="L" Type="LN" b1="PIPECREE" b2="138 KV" b3="PIP-STR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PIPECREE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRAWTON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRAWTON" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37300</SeqNum>
    <Name>L138.Selmapar-Richmond</Name>
    <LastEdit Timestamp="2025-07-31T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="RICHMOND" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHMOND" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHMOND" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="RICHMOND" b2="138 KV" b3="RIC-SEL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SELMAPAR" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SELMAPAR" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37320</SeqNum>
    <Name>L138.Delaware-Vanburen</Name>
    <LastEdit Timestamp="2026-01-23T08:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DELAWAIM" b2="138 KV" b3="DEL-VAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELAWAIM" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VANBUREN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VANBUREN" b2="138 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37350</SeqNum>
    <Name>L138.Desoto-Wesdel-Gaston</Name>
    <LastEdit Timestamp="2025-08-14T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DESOTO" b2="138 KV" b3="DES-WESD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GASTON" b2="138 KV" b3="GAS-WESD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GASTON" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GASTON" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESDEL" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37360</SeqNum>
    <Name>L138.DeerCreek-Dooville-HummelCreek</Name>
    <LastEdit Timestamp="2025-08-26T17:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCREE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEERCREE" b2="138 KV" b3="DEE-DOO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOOVILLE" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELCR" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOOVILLE" b2="138 KV" b3="DOO-HUM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37380</SeqNum>
    <Name>L138.Greentown-Grant</Name>
    <LastEdit Timestamp="2026-04-29T12:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANT" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANT" b2="138 KV" b3="GRA-GRE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="138 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37390</SeqNum>
    <Name>L138.Grant-FisherBody</Name>
    <LastEdit Timestamp="2026-04-29T12:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FISHERBO" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="FISHERBO" b2="138 KV" b3="FIS-GRA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FISHERBO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANT" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37400</SeqNum>
    <Name>L138.Greentown-HummelCreek</Name>
    <LastEdit Timestamp="2026-04-29T12:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELCR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUMMELCR" b2="138 KV" b3="HUM-GRE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37410</SeqNum>
    <Name>L138.Sorenson-Lafayette-Fogwell</Name>
    <LastEdit Timestamp="2024-10-31T08:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOGWELL" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOGWELL" b2="138 KV" b3="F1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOGWELL" b2="138 KV" b3="FOG-LAF" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAFAYETE" b2="138 KV" b3="LAF-SOR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAFAYETE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="P1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37430</SeqNum>
    <Name>L138.Sorenson-EllisonRoad</Name>
    <LastEdit Timestamp="2026-04-29T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELLISONR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELLISONR" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELLISONR" b2="138 KV" b3="ELL-SOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="N1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37440</SeqNum>
    <Name>L138.Columbia-Raber-Saturn</Name>
    <LastEdit Timestamp="2025-10-21T14:08:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLUMBIA" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLUMBIA" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COLUMBIA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLUMBIA" b2="138 KV" b3="COL-RAB1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SATURN" b2="138 KV" b3="RAB-SAT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RABER" b2="138 KV" b3="T1 LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SATURN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SATURN" b2="138 KV" b3="INDIANCR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37450</SeqNum>
    <Name>L138.Illinois-IndustrialPark</Name>
    <LastEdit Timestamp="2025-11-26T11:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ILLINOIS" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="ILLINOIS" b2="138 KV" b3="ILL-IND1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDUSTRI" b2="138 KV" b3="N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37460</SeqNum>
    <Name>L138.Mckinley-Waynedal</Name>
    <LastEdit Timestamp="2026-04-29T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCKINLEY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCKINLEY" b2="138 KV" b3="MCK-WAY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNEDAL" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37470</SeqNum>
    <Name>L138.Mckinley-IndustrialPark</Name>
    <LastEdit Timestamp="2024-09-19T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="INDUSTRI" b2="138 KV" b3="IND-MCK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDUSTRI" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCKINLEY" b2="138 KV" b3="S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37480</SeqNum>
    <Name>L138.IndustrialPark-Summit-Wallen</Name>
    <LastEdit Timestamp="2026-04-29T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="INDUSTRI" b2="138 KV" b3="IND-SUM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDUSTRI" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUMMIT" b2="138 KV" b3="SUM-WAL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUMMIT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUMMIT" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALLEN" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37490</SeqNum>
    <Name>L138.Columbia-Northeast</Name>
    <LastEdit Timestamp="2025-11-06T13:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLUMBIA" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLUMBIA" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLUMBIA" b2="138 KV" b3="COL-NOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEA2" b2="138 KV" b3="76" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37500</SeqNum>
    <Name>L138.Northeast-Kline</Name>
    <LastEdit Timestamp="2026-05-21T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KLINE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="KLINE" b2="138 KV" b3="KLI-NOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEA2" b2="138 KV" b3="855" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37510</SeqNum>
    <Name>L138.SouthwestLima-WestLima</Name>
    <LastEdit Timestamp="2026-04-29T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="138 KV" b3="J1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SWLIMA" b2="138 KV" b3="SWL-WLI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLIMA" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLIMA" b2="138 KV" b3="FA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37520</SeqNum>
    <Name>138/69/34.ShawneeRoad.T2</Name>
    <LastEdit Timestamp="2024-12-31T13:18:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWNEER" b2="138 KV" b3="2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWNEER" b2="69 KV" b3="2-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWNEER" b2="34 KV" b3="2-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEER" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEER" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHAWNEER" b2="34 KV" b3="XF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37530</SeqNum>
    <Name>L138.OrdnanceJunction-Sterling</Name>
    <LastEdit Timestamp="2025-02-07T12:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ORDNANCE" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ORDNANCE" b2="138 KV" b3="ORD-STE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORDNANCE" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERLING" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERLING" b2="138 KV" b3="S2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37540</SeqNum>
    <Name>L138.EastLima-Thayer-Hanthorn-Sterling</Name>
    <LastEdit Timestamp="2025-02-10T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMA" b2="138 KV" b3="ELI-THA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HANTHORN" b2="138 KV" b3="GOE" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANTHORN" b2="138 KV" b3="HAN-STE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERLING" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERLING" b2="138 KV" b3="S1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANTHORN" b2="138 KV" b3="HAN-THA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THAYER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THAYER" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THAYER" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THAYER" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37560</SeqNum>
    <Name>L138.WestLima-Easttown-Rockhill</Name>
    <LastEdit Timestamp="2026-05-01T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EASTTOWN" b2="138 KV" b3="EAS-ROC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTTOWN" b2="138 KV" b3="EAS-WLI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTTOWN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKHILL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLIMA" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLIMA" b2="138 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37570</SeqNum>
    <Name>L138.WestLima-Woodlawn-NWLima-EastLima</Name>
    <LastEdit Timestamp="2026-05-01T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMA" b2="138 KV" b3="ELI-NWL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NWLIMA" b2="138 KV" b3="NWL-WOO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NWLIMA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLIMA" b2="138 KV" b3="FG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLIMA" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="L" Type="LN" b1="WLIMA" b2="138 KV" b3="WLI-WOO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODLAWN" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37580</SeqNum>
    <Name>L138.EastLima-Rockhill</Name>
    <LastEdit Timestamp="2026-04-28T08:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMA" b2="138 KV" b3="ELI-ROC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKHILL" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37590</SeqNum>
    <Name>L138.EastLima-Ford</Name>
    <LastEdit Timestamp="2026-04-28T08:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMA" b2="138 KV" b3="ELI-FOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORD" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37600</SeqNum>
    <Name>L138.Ford-Rockhill</Name>
    <LastEdit Timestamp="2026-04-29T12:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FORD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="FORD" b2="138 KV" b3="FOR-ROC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKHILL" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37610</SeqNum>
    <Name>L138.EastLima-Haviland</Name>
    <LastEdit Timestamp="2025-10-17T12:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMA" b2="138 KV" b3="ELI-HAV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAVILAND" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37620</SeqNum>
    <Name>L138.Haviland-TimberRoad</Name>
    <LastEdit Timestamp="2026-04-29T12:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAVILAND" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAVILAND" b2="138 KV" b3="HAV-TIM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMBERRD" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMBERRD" b2="138 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37630</SeqNum>
    <Name>L138.Boutwell-NewLiberty</Name>
    <LastEdit Timestamp="2025-07-14T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOUTWELL" b2="138 KV" b3="BOU-NEWL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOUTWELL" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOUTWELL" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLIBER" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37640</SeqNum>
    <Name>L138.EastLima-NWoodcock</Name>
    <LastEdit Timestamp="2025-10-16T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMA" b2="138 KV" b3="ELI-NWO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWOODCOC" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37660</SeqNum>
    <Name>L138.EastLima-Campbell2-RileyCreek-YellowCreek</Name>
    <LastEdit Timestamp="2026-04-29T12:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CAMPBEL2" b2="138 KV" b3="CAM-ELI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMPBEL2" b2="138 KV" b3="CAM-MWR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMPBEL2" b2="138 KV" b3="CAM-RIL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="AA2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MWROCKPO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PPBASELN" b2="138 KV" b3="PPB-RIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PPBASELN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YELLOWCR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="RILEYCRE" b2="138 KV" b3="RIL-YEL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37670</SeqNum>
    <Name>L138.Fostoria-Softail-BuckleyRoad</Name>
    <LastEdit Timestamp="2024-12-24T13:47:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKLEYR" b2="138 KV" b3="CB-D" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTORIA" b2="138 KV" b3="FOS-SOF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="138 KV" b3="K1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RISNGSUN" b2="138 KV" b3="NCEC" />
      <ContingencyEquipment Action="L" Type="LN" b1="RISNGSUN" b2="138 KV" b3="RIS-SOF" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKLEYR" b2="138 KV" b3="BUC-SOF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37680</SeqNum>
    <Name>L138.Fostoria-WestEndFostoria</Name>
    <LastEdit Timestamp="2026-04-29T12:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTORIA" b2="138 KV" b3="FOS-WEF1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="138 KV" b3="J1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEFOSTOR" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37690</SeqNum>
    <Name>L138.Woodville-Garling-Lemoyne</Name>
    <LastEdit Timestamp="2026-03-27T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GARLING" b2="138 KV" b3="GAR-LEMO" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARLING" b2="138 KV" b3="GAR-WOOD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GARLING" b2="138 KV" b3="NSGGLASS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="138 KV" b3="13218" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVLTE" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVLTE" b2="138 KV" b3="B8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37710</SeqNum>
    <Name>L138.Fostoria-IronTriangle-Melmore</Name>
    <LastEdit Timestamp="2026-03-26T10:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="138 KV" b3="J2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTORIA" b2="138 KV" b3="FOS-IRNT" />
      <ContingencyEquipment Action="L" Type="LN" b1="IRNTRNGL" b2="138 KV" b3="IRN-MELM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IRNTRNGL" b2="138 KV" b3="LOUDON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELMORE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELMORE" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37720</SeqNum>
    <Name>L138.Greenlawn-TiffinCenter</Name>
    <LastEdit Timestamp="2026-04-29T14:15:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENLAW" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENLAW" b2="138 KV" b3="GRE-TIF1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENLAW" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENLAW" b2="138 KV" b3="T3 XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENLAW" b2="138 KV" b3="XT3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFINCE" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFINCE" b2="138 KV" b3="E2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37730</SeqNum>
    <Name>L138.Howard-Sulphurs-BucyrusCenter</Name>
    <LastEdit Timestamp="2026-04-29T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCYRUSC" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCYRUSC" b2="138 KV" b3="BUC-SUL1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUCYRUSC" b2="138 KV" b3="T1 XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOWARD2" b2="138 KV" b3="HOW-SUL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SULPHURS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37740</SeqNum>
    <Name>500/138.FlintRun.T1</Name>
    <LastEdit Timestamp="2025-08-13T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="500 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="500 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLINTRUN" b2="500 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37750</SeqNum>
    <Name>L138.Howard-NorthBelleville</Name>
    <LastEdit Timestamp="2024-10-31T11:07:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOWARD2" b2="138 KV" b3="HOW-NBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBELLVIL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBELLVIL" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="X" Type="XF" b1="NBELLVIL" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37760</SeqNum>
    <Name>L138.Auburn-DuntonLake-RobisonPark</Name>
    <LastEdit Timestamp="2025-05-30T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AUBURN" b2="138 KV" b3="AUB-DUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUBURN" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROBISONP" b2="138 KV" b3="DUN-ROB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="G4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37780</SeqNum>
    <Name>L138.Albion-Ege-Laotto-Hathawrd-Huntwn-RobisonPark</Name>
    <LastEdit Timestamp="2025-09-23T13:19:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBIONIM" b2="138 KV" b3="ALB-EGE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBIONIM" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="EGE" b2="138 KV" b3="EGE-LAO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EGE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HATHAWRD" b2="138 KV" b3="HAT-LAOT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HATHAWRD" b2="138 KV" b3="HATHROAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="HATHAWRD" b2="138 KV" b3="HAT-HUNT" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTEAEP" b2="138 KV" b3="HUN-ROBI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUNTEAEP" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAOTTO" b2="138 KV" b3="LAO-LAO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAOTTO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="E3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37790</SeqNum>
    <Name>L138.Albion-Burnworth-Charger</Name>
    <LastEdit Timestamp="2024-12-26T15:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBIONIM" b2="138 KV" b3="ALB-BURN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBIONIM" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHARGER" b2="138 KV" b3="BUR-CHAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BURNWRTH" b2="138 KV" b3="REMC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARGER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARGER" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37800</SeqNum>
    <Name>L138.Albion-Northport [NIPS]</Name>
    <LastEdit Timestamp="2024-11-19T16:18:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBIONIM" b2="138 KV" b3="ALB-NOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBIONIM" b2="138 KV" b3="I" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHPOR" b2="138 KV" b3="56_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHPOR" b2="138 KV" b3="56_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37810</SeqNum>
    <Name>L138.RobisonPark-Dupont-WoodsRoad-Diamond-Guardian</Name>
    <LastEdit Timestamp="2024-12-31T13:30:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DIAMOND" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUPONTRD" b2="138 KV" b3="DUP-ROB1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUPONTRD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUARDIAN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="DIAMOND" b2="138 KV" b3="DIA-GUA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GUARDIAN" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WOODSRD" b2="138 KV" b3="DIA-WOO" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUPONTRD" b2="138 KV" b3="DUP-WOO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODSRD" b2="138 KV" b3="T12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37820</SeqNum>
    <Name>L138.Twinbranch-McNutt</Name>
    <LastEdit Timestamp="2025-10-21T14:14:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCNUTT" b2="138 KV" b3="M008Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCNUTT" b2="138 KV" b3="M009E5" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCNUTT" b2="138 KV" b3="MCN-TWIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="F2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37840</SeqNum>
    <Name>L138.RobisonPark-Allen</Name>
    <LastEdit Timestamp="2025-12-26T13:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="F1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENIM" b2="138 KV" b3="ALL-ROBI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37900</SeqNum>
    <Name>L138.Adams-Pennville-Jay</Name>
    <LastEdit Timestamp="2026-01-23T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSIM" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSIM" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JAY" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JAY" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JAY" b2="138 KV" b3="JAY-PEN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENNVILL" b2="138 KV" b3="PEN-ADA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENNVILL" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37910</SeqNum>
    <Name>L138.JacksonRoad-Ireland-Dragoon</Name>
    <LastEdit Timestamp="2025-12-29T10:43:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DRAGOON" b2="138 KV" b3="DRA-IRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAGOON" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="IRELANDR" b2="138 KV" b3="IRE-JAC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IRELANDR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="138 KV" b3="L1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37930</SeqNum>
    <Name>L138.JacksonRoad-SSide-Studebaker</Name>
    <LastEdit Timestamp="2024-10-23T13:11:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSONR" b2="138 KV" b3="JAC-SSI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="138 KV" b3="K1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SSIDE" b2="138 KV" b3="SSI-STU1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SSIDE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUDEBAK" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STUDEBAK" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUDEBAK" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37940</SeqNum>
    <Name>L138.JacksonRoad-Calvert-Kankakee</Name>
    <LastEdit Timestamp="2024-10-22T16:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CALVERT" b2="138 KV" b3="CAL-JAC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CALVERT" b2="138 KV" b3="CAL-KAN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CALVERT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="138 KV" b3="K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANKAKEE" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37950</SeqNum>
    <Name>L138.Studebaker-EastSide</Name>
    <LastEdit Timestamp="2026-05-01T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ESIDEIM" b2="138 KV" b3="ESI-STU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESIDEIM" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESIDEIM" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUDEBAK" b2="138 KV" b3="C CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STUDEBAK" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUDEBAK" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37960</SeqNum>
    <Name>L138.Dunlap-Concord</Name>
    <LastEdit Timestamp="2025-03-18T15:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONCORD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONCORD" b2="138 KV" b3="CON-DUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNLAP" b2="138 KV" b3="P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37980</SeqNum>
    <Name>L138.Olive-NewCarlisle</Name>
    <LastEdit Timestamp="2026-05-04T15:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCARLI" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWCARLI" b2="138 KV" b3="NEW-OLI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="138 KV" b3="Q1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>37990</SeqNum>
    <Name>L138.Olive-German-NotreDame</Name>
    <LastEdit Timestamp="2026-05-04T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GERMAN" b2="138 KV" b3="GER-NOT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GERMAN" b2="138 KV" b3="GER-OLI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GERMAN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GERMAN" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTREDAM" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NOTREDAM" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="138 KV" b3="R1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38000</SeqNum>
    <Name>L138.Olive-RickermanRd</Name>
    <LastEdit Timestamp="2026-05-04T15:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="138 KV" b3="Q2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICKERMA" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICKERMA" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="OLIVE" b2="138 KV" b3="OLI-RIC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38010</SeqNum>
    <Name>L138.Olive-Edison</Name>
    <LastEdit Timestamp="2026-05-04T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDISON2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDISON2" b2="138 KV" b3="EDI-OLI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="138 KV" b3="R2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38020</SeqNum>
    <Name>L138.NewCarlisle-Pineroad-Ameriplex</Name>
    <LastEdit Timestamp="2024-09-25T12:44:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMERIPLX" b2="138 KV" b3="AME-PINE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMERIPLX" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCARLI" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWCARLI" b2="138 KV" b3="NEW-PIN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PINEROAD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38030</SeqNum>
    <Name>L138.Pletcher-Baroda-Derby</Name>
    <LastEdit Timestamp="2025-05-09T10:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BARODA" b2="138 KV" b3="BAR-PLE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BARODA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DERBY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BARODA" b2="138 KV" b3="BAR-DER1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLETCHER" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLETCHER" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38040</SeqNum>
    <Name>L138.Bosserman-TrailCreek</Name>
    <LastEdit Timestamp="2026-05-04T15:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOSSERMN" b2="138 KV" b3="BOS-TRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRAILCRE" b2="138 KV" b3="52" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38050</SeqNum>
    <Name>L138.NewCarlisle-Maple</Name>
    <LastEdit Timestamp="2026-05-04T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLNIPS" b2="138 KV" b3="16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCARLI" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWCARLI" b2="138 KV" b3="NEW-MAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38060</SeqNum>
    <Name>L138.SouthBend-TwinBranch</Name>
    <LastEdit Timestamp="2026-05-04T15:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SBENDAEP" b2="138 KV" b3="SBE-TWI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBENDAEP" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TWINBRAN" b2="138 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38070</SeqNum>
    <Name>L138.SouthBend-EastSide</Name>
    <LastEdit Timestamp="2026-05-05T09:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ESIDEIM" b2="138 KV" b3="ESI-SBE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESIDEIM" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ESIDEIM" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBENDAEP" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38080</SeqNum>
    <Name>L138.HickoryCreek-Crystal-BentonHarbor</Name>
    <LastEdit Timestamp="2026-05-04T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BENTONHA" b2="138 KV" b3="BEN-CRY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRYSTAL" b2="138 KV" b3="CRY-HIC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRYSTAL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORYC" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38090</SeqNum>
    <Name>L138.HickoryCreek-Nickerson-Sodus-KenzieCreek</Name>
    <LastEdit Timestamp="2026-05-04T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORYC" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="HICKORYC" b2="138 KV" b3="HIC-NIC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="138 KV" b3="F2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENZIECR" b2="138 KV" b3="KEN-SOD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NICKERSO" b2="138 KV" b3="NIC-SOD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NICKERSO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SODUS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38100</SeqNum>
    <Name>L138.CapitalAvenue-TwinBranch</Name>
    <LastEdit Timestamp="2026-05-04T15:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CAPITALA" b2="138 KV" b3="CAP-TWI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPITALA" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPITALA" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="D2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38110</SeqNum>
    <Name>138/69/34.Mottville.TX5</Name>
    <LastEdit Timestamp="2024-07-26T10:19:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MOTTVILL" b2="138 KV" b3="5-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOTTVILL" b2="69 KV" b3="5-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOTTVILL" b2="34 KV" b3="5-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTTVILL" b2="34 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MOTTVILL" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTTVILL" b2="138 KV" b3="XT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38120</SeqNum>
    <Name>L138.BlossomTrail-Riverside</Name>
    <LastEdit Timestamp="2025-07-31T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLOSSOMT" b2="138 KV" b3="BLO-RIVE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLOSSOMT" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLOSSOMT" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSIM" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38130</SeqNum>
    <Name>L138.KenzieCreek-Colby-HassleSw-Valley</Name>
    <LastEdit Timestamp="2026-06-09T15:43:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLBY" b2="138 KV" b3="COL-KEN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLBY" b2="34.5 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COLBY" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLBY" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLBY" b2="138 KV" b3="COL-HASS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HASSLESW" b2="138 KV" b3="WOLVERIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="138 KV" b3="G1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HASSLESW" b2="138 KV" b3="HAS-VALL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEYIM" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38140</SeqNum>
    <Name>L138.BentonHarbor-Riverside.1</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BENTONHA" b2="138 KV" b3="BEN-RIV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSIM" b2="138 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38150</SeqNum>
    <Name>L138.BentonHarbor-Riverside.2</Name>
    <LastEdit Timestamp="2026-05-04T15:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BENTONHA" b2="138 KV" b3="BEN-RIV2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSIM" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38160</SeqNum>
    <Name>L138.Riverside-MainStreet</Name>
    <LastEdit Timestamp="2025-02-21T14:56:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINSTRE" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAINSTRE" b2="138 KV" b3="MAI-RIV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSIM" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38170</SeqNum>
    <Name>L138.Hartford-Valley</Name>
    <LastEdit Timestamp="2026-05-04T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARTFORD" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARTFORD" b2="138 KV" b3="HAR-VAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEYIM" b2="138 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38180</SeqNum>
    <Name>L138.JacksonsFerry-PeakCreek</Name>
    <LastEdit Timestamp="2026-05-04T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSONS" b2="138 KV" b3="JAC-PEA1" />
      <ContingencyEquipment Action="S" Type="SD" b1="JACKSONS" b2="138 KV" b3="REACTOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="S1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEAKCREE" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38190</SeqNum>
    <Name>L138.JacksonsFerry-Wildwood-Huffman</Name>
    <LastEdit Timestamp="2024-11-06T12:46:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUFFMAN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUFFMAN" b2="138 KV" b3="HUF-WILD" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSONS" b2="138 KV" b3="JAC-WILD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="P2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILDWOOD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38200</SeqNum>
    <Name>L138.PeakCreek-Westglow-Wurno-Claytor</Name>
    <LastEdit Timestamp="2025-05-15T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYTOR" b2="138 KV" b3="CLA-WUR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEAKCREE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="PEAKCREE" b2="138 KV" b3="PEA-WES" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTGLOW" b2="138 KV" b3="JAMESHAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WURNO" b2="138 KV" b3="AA_CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WURNO" b2="138 KV" b3="CAPA" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WURNO" b2="138 KV" b3="CLOYDMLF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WURNO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WURNO" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WURNO" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="L" Type="LN" b1="WESTGLOW" b2="138 KV" b3="WES-WUR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WURNO" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WURNO" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38210</SeqNum>
    <Name>L138.Huffman-WillisGap</Name>
    <LastEdit Timestamp="2026-05-04T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HUFFMAN" b2="138 KV" b3="BYPS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUFFMAN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUFFMAN" b2="138 KV" b3="HUF-WIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILLISGA" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38220</SeqNum>
    <Name>L138.Huffman-Pipers-WCarroll-WolfGlade</Name>
    <LastEdit Timestamp="2025-05-15T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUFFMAN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUFFMAN" b2="138 KV" b3="HUF-PIP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PIPERSGA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PIPERSGA" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PIPERSGA" b2="138 KV" b3="PIP-WCAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WCARROLL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFGLAD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFGLAD" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WCARROLL" b2="138 KV" b3="WCA-WOLF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38230</SeqNum>
    <Name>L138.Axton-Danville.1</Name>
    <LastEdit Timestamp="2026-05-04T15:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AXTONAEP" b2="138 KV" b3="AXT-DAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AXTONAEP" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AXTONAEP" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANVILLE" b2="138 KV" b3="N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38240</SeqNum>
    <Name>L138.Axton-BerryHill</Name>
    <LastEdit Timestamp="2026-02-12T09:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AXTONAEP" b2="138 KV" b3="AXT-BERR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AXTONAEP" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AXTONAEP" b2="138 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERRYHIL" b2="138 KV" b3="A000G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERRYHIL" b2="138 KV" b3="A000H5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38250</SeqNum>
    <Name>L138.Axton-Martinsville-Collins2-Fieldale</Name>
    <LastEdit Timestamp="2025-05-19T15:13:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AXTONAEP" b2="138 KV" b3="AXT-MAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AXTONAEP" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AXTONAEP" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLLINS2" b2="138 KV" b3="COL-FIE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLLINS2" b2="138 KV" b3="COL-MAR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COLLINS2" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDALE" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSV" b2="138 KV" b3="K" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38260</SeqNum>
    <Name>L138.Axton-Stockton-Martinsville</Name>
    <LastEdit Timestamp="2025-10-21T12:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AXTONAEP" b2="138 KV" b3="AXT-STO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AXTONAEP" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AXTONAEP" b2="138 KV" b3="J2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSV" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARTINSV" b2="138 KV" b3="MAR-STO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STOCKTO2" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38270</SeqNum>
    <Name>L138.Danville-EastDanville</Name>
    <LastEdit Timestamp="2026-05-04T15:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DANVILLE" b2="138 KV" b3="DAN-EDA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANVILLE" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDANVILL" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38280</SeqNum>
    <Name>L138.Martinsville-PatriotCentre-Fieldale</Name>
    <LastEdit Timestamp="2026-05-04T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDALE" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSV" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="L" Type="LN" b1="PATRIOTC" b2="138 KV" b3="FIE-PAT" />
      <ContingencyEquipment Action="L" Type="LN" b1="PATRIOTC" b2="138 KV" b3="MAR-PAT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PATRIOTC" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38290</SeqNum>
    <Name>L138.Fieldale-Thorton-Franklin2-Blaine</Name>
    <LastEdit Timestamp="2026-01-12T11:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAINE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLAINE" b2="138 KV" b3="BLA-FRA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIELDALE" b2="138 KV" b3="FIE-THO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDALE" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKLI2" b2="138 KV" b3="FRA-THO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRANKLI2" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRANKLI2" b2="138 KV" b3="T5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THORNTON" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THORNTON" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38300</SeqNum>
    <Name>L138.Fieldale-Oaklevel-Grassyhill-Roanoke</Name>
    <LastEdit Timestamp="2026-05-04T15:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FIELDALE" b2="138 KV" b3="FIE-OAK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDALE" b2="138 KV" b3="O" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRASSYHI" b2="138 KV" b3="GRA-OAK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRASSYHI" b2="138 KV" b3="GRA-ROA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRASSYHI" b2="138 KV" b3="GRA-TAN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKLEVEL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TANKHILL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38310</SeqNum>
    <Name>L138.Fieldale-CommonwealthCrossing</Name>
    <LastEdit Timestamp="2025-05-12T14:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COMMONWC" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="COMMONWC" b2="138 KV" b3="COM-FIEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDALE" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38320</SeqNum>
    <Name>L138.Blaine-Roanoke</Name>
    <LastEdit Timestamp="2026-01-12T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAINE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLAINE" b2="138 KV" b3="BLA-ROA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38340</SeqNum>
    <Name>L138.EastMonument-Rigis</Name>
    <LastEdit Timestamp="2025-08-14T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EMONUMEN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="EMONUMEN" b2="138 KV" b3="EMO-RIG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIGIS" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38360</SeqNum>
    <Name>L138.SmithMtn-Leesville</Name>
    <LastEdit Timestamp="2026-05-05T14:11:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LEESVILL" b2="138 KV" b3=".  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESVILL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LEESVILL" b2="13 KV" b3="LE1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LEESVILL" b2="13 KV" b3="LE2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEESVILL" b2="138 KV" b3="LEE-SMI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38370</SeqNum>
    <Name>L138.Redeye-Candlers-OpossumCreek</Name>
    <LastEdit Timestamp="2025-04-18T17:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CANDLERS" b2="138 KV" b3="CAN-OPO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANDLERS" b2="138 KV" b3="CAN-REDE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANDLERS" b2="138 KV" b3="CAN-RUS1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CANDLERS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPOSSUMC" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPOSSUMC" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDEYE" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDEYE" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RUSTBURG" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38380</SeqNum>
    <Name>L138.SmithMtn-Rockcast-Moneta-Cloverdale</Name>
    <LastEdit Timestamp="2024-10-25T13:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADSSTO" b2="138 KV" b3="CLO-MEA" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADSSTO" b2="138 KV" b3="MEA-MON" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MEADSSTO" b2="138 KV" b3="SSIDE" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONETA" b2="138 KV" b3="MON-ROC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONETA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKCAST" b2="138 KV" b3="ROC-SMI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKCAST" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="A2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38390</SeqNum>
    <Name>L138.Broadford-Saltville.2</Name>
    <LastEdit Timestamp="2025-11-06T13:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROADFO2" b2="138 KV" b3="BRO-SAL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="138 KV" b3="F2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTVILL" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38400</SeqNum>
    <Name>L138.Broadford-Claypool-Richland</Name>
    <LastEdit Timestamp="2025-08-11T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROADFO2" b2="138 KV" b3="BRO-CLA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYPOOL" b2="138 KV" b3="CLA-RIC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLAYPOOL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLAYPOOL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLAND" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLAND" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38410</SeqNum>
    <Name>L138.Broadford-Saltville.1</Name>
    <LastEdit Timestamp="2025-09-02T10:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROADFO2" b2="138 KV" b3="BRO-SAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="138 KV" b3="F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTVILL" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38420</SeqNum>
    <Name>L138.Broadford-Smyth-Atkins</Name>
    <LastEdit Timestamp="2025-08-04T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ATKINS" b2="138 KV" b3="ATK-SMY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATKINS" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROADFO2" b2="138 KV" b3="BRO-SMY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="138 KV" b3="G1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SMYTH" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SMYTH" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38440</SeqNum>
    <Name>L138.Gahanna-HapCremean</Name>
    <LastEdit Timestamp="2026-05-04T15:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="108" />
      <ContingencyEquipment Action="L" Type="LN" b1="GAHANNA" b2="138 KV" b3="GAH-HAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAPCREME" b2="138 KV" b3="13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAPCREME" b2="138 KV" b3="14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38450</SeqNum>
    <Name>L138.SouthwestLima-WestMoulton</Name>
    <LastEdit Timestamp="2025-11-04T16:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="138 KV" b3="K2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SWLIMA" b2="138 KV" b3="SWL-WMO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMOULTON" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMOULTON" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38470</SeqNum>
    <Name>L138.Sowers-Grabill-RobisonPark</Name>
    <LastEdit Timestamp="2025-04-25T17:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GRABILL" b2="138 KV" b3="GRA-ROB1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRABILL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="E4" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRABILL" b2="138 KV" b3="GRA-SOWR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOWERS" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOWERS" b2="138 KV" b3="K2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38490</SeqNum>
    <Name>L138.TiffinCenter-FremontCenter.2</Name>
    <LastEdit Timestamp="2024-10-28T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONTC" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFINCE" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFINCE" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FREMONTC" b2="138 KV" b3="FRE-TIF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38500</SeqNum>
    <Name>L138.Sporn-Rutland</Name>
    <LastEdit Timestamp="2026-05-05T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RUTLAND" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="N1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPORNAEP" b2="138 KV" b3="SPO-RUT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38510</SeqNum>
    <Name>138/69.Bearskin.TX1 (N.O.)</Name>
    <LastEdit Timestamp="2025-02-28T12:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARSKI4" b2="69 KV" b3="17302" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARSKI4" b2="138 KV" b3="H102" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEARSKI4" b2="138 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38520</SeqNum>
    <Name>L138.Lick-L69-Sporn</Name>
    <LastEdit Timestamp="2024-10-25T13:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ADDISON" b2="138 KV" b3="ADD-ROD" />
      <ContingencyEquipment Action="X" Type="XF" b1="ADDISON" b2="138 KV" b3="T3_XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADDISON" b2="138 KV" b3="XT3" />
      <ContingencyEquipment Action="L" Type="LN" b1="L69" b2="138 KV" b3="L69-LIC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="L69" b2="138 KV" b3="L69-RIO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICK" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICK" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIO" b2="138 KV" b3="RIO-ROD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIO" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RODNEY" b2="138 KV" b3="BUCKEYE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="L1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPORNAEP" b2="138 KV" b3="SPO-L691" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38530</SeqNum>
    <Name>L138.Darrah-MerrittsCreek-Cabell-Milton2</Name>
    <LastEdit Timestamp="2025-12-16T11:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CABELL" b2="138 KV" b3="CAB-MIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CABELL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CABELL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARRAH" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERRITTS" b2="138 KV" b3="CAB-MER" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERRITTS" b2="138 KV" b3="DAR-MER" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MERRITTS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILTON2" b2="138 KV" b3="BAKERID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON2" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON2" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILTON2" b2="138 KV" b3="JOHNSCK" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILTON2" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILTON2" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MILTON2" b2="69 KV" b3="X1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON2" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON2" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38560</SeqNum>
    <Name>L138.Chadwick-Tristate.2</Name>
    <LastEdit Timestamp="2025-07-29T12:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHADWICK" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRISTATE" b2="138 KV" b3="TRI-CHA2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38570</SeqNum>
    <Name>L138.Chadwick-Tristate.1</Name>
    <LastEdit Timestamp="2026-05-04T15:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHADWICK" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRISTATE" b2="138 KV" b3="TRI-CHA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38580</SeqNum>
    <Name>L138.WestHuntingdon-Tristate</Name>
    <LastEdit Timestamp="2026-05-05T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRISTATE" b2="138 KV" b3="TRI-WHU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHUNTING" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38590</SeqNum>
    <Name>L138.WHuntingdon-Shoals</Name>
    <LastEdit Timestamp="2026-05-05T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHOALS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHOALS" b2="138 KV" b3="SHO-WHU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHOALS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHOALS" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHUNTING" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38600</SeqNum>
    <Name>L138.Amos-Bancroft-SouthBuffalo</Name>
    <LastEdit Timestamp="2025-05-02T13:01:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="138 KV" b3="AMO-BAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="G CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="G1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BANCROFT" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BANCROFT" b2="138 KV" b3="BAN-SBU1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BANCROFT" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BANCROFT" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BANCROFT" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BANCROFT" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BANCROFT" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBUFFALO" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBUFFALO" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38610</SeqNum>
    <Name>L138.Amos-StAlbans-Angelbranch-Hopkins</Name>
    <LastEdit Timestamp="2026-05-04T15:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="138 KV" b3="AMO-STA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANGELBRA" b2="138 KV" b3="ANG-GRA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANGELBRA" b2="138 KV" b3="ANG-HOP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANGELBRA" b2="138 KV" b3="ANG-STA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRASSYFO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPKINS" b2="138 KV" b3="AB" />
      <ContingencyEquipment Action="S" Type="SD" b1="HOPKINS" b2="138 KV" b3="HOPKINS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOPKINS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOPKINS" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOPKINS" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STALBANS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38620</SeqNum>
    <Name>L138.Logan-RumCreek-HuffCreek-Wyoming</Name>
    <LastEdit Timestamp="2025-11-10T11:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HUFFCREE" b2="138 KV" b3="HUF-RUM1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUFFCREE" b2="138 KV" b3="HUF-TOLE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUFFCREE" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGAN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOGAN" b2="138 KV" b3="LOG-RUM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUMCREEK" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUMCREEK" b2="138 KV" b3="RUM-RUM1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RUMCREEK" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TOLER" b2="138 KV" b3="DYNAMIC" />
      <ContingencyEquipment Action="L" Type="LN" b1="TOLER" b2="138 KV" b3="TOL-WYOM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="138 KV" b3="H1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38630</SeqNum>
    <Name>L138.Logan-Lyburn-Wyoming</Name>
    <LastEdit Timestamp="2025-04-07T15:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGAN" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOGAN" b2="138 KV" b3="LOG-LYBU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LYBURN" b2="138 KV" b3="BANDMILL" />
      <ContingencyEquipment Action="L" Type="LN" b1="LYBURN" b2="138 KV" b3="LYB-WYOM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="138 KV" b3="K2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38640</SeqNum>
    <Name>L138.Logan-NorthPointe-TraceFork-Hopkins</Name>
    <LastEdit Timestamp="2025-11-20T14:21:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPKINS" b2="138 KV" b3="AB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPKINS" b2="138 KV" b3="HOP-TRA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGAN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOGAN" b2="138 KV" b3="LOG-NPO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NPOINTE" b2="138 KV" b3="NPO-TRA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NPOINTE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHARPLES" b2="138 KV" b3="DTCC" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHARPLES" b2="138 KV" b3="SHA-TRA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STONEBRA" b2="138 KV" b3="STO-TRA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38670</SeqNum>
    <Name>L138.ReedyCreek-ShortHill-OreBank-Holston</Name>
    <LastEdit Timestamp="2026-03-26T14:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HOLSTON" b2="138 KV" b3="HOL-ORE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLSTON" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="L" Type="LN" b1="OREBANK" b2="138 KV" b3="ORE-SHO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OREBANK" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OREBANK" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="REEDYCRE" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="REEDYCRE" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="REEDYCRE" b2="34.5 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEDYCRE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="REEDYCRE" b2="138 KV" b3="CAPAA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEDYCRE" b2="34.5 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="REEDYCRE" b2="138 KV" b3="REE-SHO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REEDYCRE" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHORTHIL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHORTHIL" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38690</SeqNum>
    <Name>345/138.Roberts.T1</Name>
    <LastEdit Timestamp="2026-04-27T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="345 KV" b3="A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="F1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROBERTS2" b2="345 KV" b3="T-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38710</SeqNum>
    <Name>L161.Hazard-Wooten</Name>
    <LastEdit Timestamp="2026-05-05T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HAZARD" b2="161 KV" b3="HAZ-WOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZARD" b2="161 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOOTEN" b2="161 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38720</SeqNum>
    <Name>L161.Leslie-Wooten</Name>
    <LastEdit Timestamp="2025-12-16T12:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LESLIE" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LESLIE" b2="161 KV" b3="K" />
      <ContingencyEquipment Action="S" Type="SD" b1="LESLIE" b2="69 KV" b3="LESLIE" />
      <ContingencyEquipment Action="X" Type="XF" b1="LESLIE" b2="161 KV" b3="XFMR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LESLIE" b2="161 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOOTEN" b2="161 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="LESLIE" b2="161 KV" b3="LES-WOO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38730</SeqNum>
    <Name>L161.Arnold-Delvinta-Wooten</Name>
    <LastEdit Timestamp="2026-05-05T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARNOLD" b2="161 KV" b3="B121_804" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARNOLD" b2="161 KV" b3="B121_807" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELVINTA" b2="161 KV" b3="B139_824" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELVINTA" b2="161 KV" b3="B139_827" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELVINTA" b2="161 KV" b3="DEL-WOOT" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARNOLD" b2="161 KV" b3="ARN-WOOT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOOTEN" b2="161 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="HYDENLGE" b2="161 KV" b3="HYD-WOO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38740</SeqNum>
    <Name>L161.Leslie-Stinnett-Pineville</Name>
    <LastEdit Timestamp="2026-05-05T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LESLIE" b2="161 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="LESLIE" b2="161 KV" b3="LES-STI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEVTVA" b2="161 KV" b3="944" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PINEVTVA" b2="161 KV" b3="949 DIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="STINNETT" b2="161 KV" b3="STI-PIN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STINNETT" b2="161 KV" b3="T1 LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STINNETT" b2="161 KV" b3="T2 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38750</SeqNum>
    <Name>L138.Waverly-WareRoad</Name>
    <LastEdit Timestamp="2026-05-05T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAREROAD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAREROAD" b2="138 KV" b3="LOADT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAREROAD" b2="138 KV" b3="WAR-WAV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY2" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY2" b2="138 KV" b3="103" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38760</SeqNum>
    <Name>L138.ClevelandCliffs-Rockpwks.1</Name>
    <LastEdit Timestamp="2024-12-09T14:16:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLEVELCL" b2="138 KV" b3="10" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLEVELCL" b2="138 KV" b3="CLE-ROC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPWKS" b2="138 KV" b3="T7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPWKS" b2="138 KV" b3="TIE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38770</SeqNum>
    <Name>L138.ClevelandCliffs-Rockpwks.2</Name>
    <LastEdit Timestamp="2024-12-09T14:16:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLEVELCL" b2="138 KV" b3="20" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLEVELCL" b2="138 KV" b3="CLE-ROC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPWKS" b2="138 KV" b3="T8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPWKS" b2="138 KV" b3="TIE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38780</SeqNum>
    <Name>L138.SECanton-Shepler-Timken</Name>
    <LastEdit Timestamp="2026-05-05T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AGAGAS1" b2="138 KV" b3="AGA-SHE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AGAGAS1" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AGAGAS1" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SECANTON" b2="138 KV" b3="SEC-SHE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHEPLER" b2="138 KV" b3="SHE-TIM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMKEN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIMKEN" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38790</SeqNum>
    <Name>L138.Auburn-Dekalb [NIPS]</Name>
    <LastEdit Timestamp="2026-05-04T15:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AUBURN" b2="138 KV" b3="AUB-DEK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUBURN" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="X" Type="XF" b1="DEKALB" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEKALB" b2="69 KV" b3="6986" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38800</SeqNum>
    <Name>L138.AppleGrove-SapphireSw-Scottown-Solida-SPoint</Name>
    <LastEdit Timestamp="2025-12-18T17:02:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="APPLEGRO" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="L" Type="LN" b1="APPLEGRO" b2="138 KV" b3="APP-SAPP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SAPPHISW" b2="138 KV" b3="NUCOR" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAPPHISW" b2="138 KV" b3="SAP-SCOT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCOTTOWN" b2="138 KV" b3="T-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCOTTOWN" b2="138 KV" b3="SCO-SOLI" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOLIDA" b2="138 KV" b3="SOL-SPOI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOLIDA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOINT" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38810</SeqNum>
    <Name>L138.AppleGrove-ShellOil.1</Name>
    <LastEdit Timestamp="2026-05-04T15:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="APPLEGRO" b2="138 KV" b3="APP-MER1" />
      <ContingencyEquipment Action="L" Type="LN" b1="APPLEGRO" b2="138 KV" b3="APP-SHE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="APPLEGRO" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="APPLEGRO" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHELLOIL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38820</SeqNum>
    <Name>L138.AppleGrove-ShellOil.2</Name>
    <LastEdit Timestamp="2024-11-08T10:00:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="APPLEGRO" b2="138 KV" b3="APP-SHE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="APPLEGRO" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="APPLEGRO" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="APPLEGRO" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="X" Type="XF" b1="APPLEGRO" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHELLOIL" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38830</SeqNum>
    <Name>L138.Tazewell-Carswelt-Trailfork</Name>
    <LastEdit Timestamp="2026-05-06T10:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARSWELL" b2="138 KV" b3="CAR-CAR4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARSWELL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARSWELT" b2="138 KV" b3="CAR-CLA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLARKBRA" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLARKBRA" b2="138 KV" b3="CLA-HOR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HORSEPEN" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="HORSEPEN" b2="138 KV" b3="HOR-TAZ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWELL" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWELL" b2="138 KV" b3="M1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRAILFOR" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRAILFOR" b2="138 KV" b3="TRA-CAR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38840</SeqNum>
    <Name>L138.HalesBranch-Sourwood-Padfork-Baileysville</Name>
    <LastEdit Timestamp="2026-05-06T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAILEYSV" b2="138 KV" b3="BAI-PAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAILEYSV" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HALESBRA" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HALESBRA" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEFTFORK" b2="138 KV" b3="HAL-LEF" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARMON" b2="138 KV" b3="HAR-PAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARMON" b2="138 KV" b3="HAR-SOU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARMON" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEFTFORK" b2="138 KV" b3="LEF-LOO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEFTFORK" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOONEYCR" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOONEYCR" b2="138 KV" b3="XF-T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PADFORK" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOURWOOD" b2="138 KV" b3="SOU-HAL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOURWOOD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38850</SeqNum>
    <Name>L138.Baileysville-Wyoming.1</Name>
    <LastEdit Timestamp="2026-05-05T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAILEYSV" b2="138 KV" b3="BAI-WYO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAILEYSV" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="138 KV" b3="G2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38860</SeqNum>
    <Name>L138.Baileysville-Wyoming.2</Name>
    <LastEdit Timestamp="2026-05-05T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAILEYSV" b2="138 KV" b3="BAI-WYO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAILEYSV" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="138 KV" b3="H2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38880</SeqNum>
    <Name>L138.Gavin-CartwrightSW-Bcaddisn-Thivener-Ncrownci</Name>
    <LastEdit Timestamp="2025-10-20T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BCADDISN" b2="138 KV" b3="BCA-CART" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BCADDISN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARTWRIS" b2="138 KV" b3="CAR-GAVI" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARTWRIS" b2="138 KV" b3="CAR-THIV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="138 KV" b3="AC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="138 KV" b3="AC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NCROWNCI" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="L" Type="LN" b1="NCROWNCI" b2="138 KV" b3="NCR-THI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PATRIOT" b2="138 KV" b3="PAT-THI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PATRIOT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="THIVENER" b2="138 KV" b3="SPOI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38890</SeqNum>
    <Name>L138.BeaverCreek-Kewanee</Name>
    <LastEdit Timestamp="2024-11-12T15:41:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVERCR" b2="138 KV" b3="BEA-KEWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEWANEE2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEWANEE2" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38900</SeqNum>
    <Name>L138.BeaverCreek-ConsolMetering-SoftShell</Name>
    <LastEdit Timestamp="2026-05-06T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVERCR" b2="138 KV" b3="BEA-CON1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BEAVERCR" b2="138 KV" b3="HASP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOFTSHEL" b2="138 KV" b3="CON-SOF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONSOLID" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOFTSHEL" b2="138 KV" b3="K" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38910</SeqNum>
    <Name>L138.Beckham-Vicco-Hazard</Name>
    <LastEdit Timestamp="2025-11-04T16:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BECKHAM" b2="138 KV" b3="BEC-VIC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKHAM" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAZARD" b2="138 KV" b3="HAZ-VIC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZARD" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VICCO" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38940</SeqNum>
    <Name>L138.Brues-Bethlehem-CountyLine-Sandhill</Name>
    <LastEdit Timestamp="2026-05-05T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BETHLEHE" b2="138 KV" b3="BET-BRU" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHLEHE" b2="138 KV" b3="BET-COU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHLEHE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUES" b2="138 KV" b3="D1 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COUNTYLI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COUNTYLI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="COUNTYLI" b2="138 KV" b3="COU-SAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38960</SeqNum>
    <Name>L138.SBluefield-Erivermo-SPrinceton</Name>
    <LastEdit Timestamp="2026-05-05T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ERIVERMO" b2="138 KV" b3="ERI-SBL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERIVERMO" b2="138 KV" b3="ERI-SPR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ERIVERMO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBLUEFIE" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINCET" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38970</SeqNum>
    <Name>L138.EAmsterdam-Pandard-JuneRd</Name>
    <LastEdit Timestamp="2025-01-30T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EAMSTERD" b2="138 KV" b3="EAM-PAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAMSTERD" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNEROAD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNEROAD" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PANDARD" b2="138 KV" b3="CARROLL" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNEROAD" b2="138 KV" b3="JUN-PAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>38990</SeqNum>
    <Name>L138.NewLondon-Johnsonm-Otter-Altavista</Name>
    <LastEdit Timestamp="2026-05-05T09:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAVSTA" b2="138 KV" b3="1332" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSONM" b2="138 KV" b3="JOH-NEW1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSONM" b2="138 KV" b3="JOH-OTT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSONM" b2="138 KV" b3="S-C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JOHNSONM" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLONDO" b2="138 KV" b3="D CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OTTER" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTER" b2="138 KV" b3="ODEC" />
      <ContingencyEquipment Action="L" Type="LN" b1="OTTER" b2="138 KV" b3="OTT-ALT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39000</SeqNum>
    <Name>L138.Tazewell-Buckhorn-Lonesome-Hockman</Name>
    <LastEdit Timestamp="2024-05-21T12:25:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKHORN" b2="138 KV" b3="BUC-TAZ1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUCKHORN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUCKHORN" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOCKMAN" b2="138 KV" b3="A000B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOCKMAN" b2="138 KV" b3="HOC-LONE" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONESOME" b2="138 KV" b3="LON-BUC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LONESOME" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWELL" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWELL" b2="138 KV" b3="K1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39010</SeqNum>
    <Name>L138.EElkhart-Nrthlnd-MnrTp-Cabot-Clvlnd-CapitalAv</Name>
    <LastEdit Timestamp="2026-03-09T11:55:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CABOTBER" b2="138 KV" b3="CAB-CLE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CABOTBER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPITALA" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPITALA" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPITALA" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAPITALA" b2="138 KV" b3="CAP-CLE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLEVELAN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EELKHART" b2="138 KV" b3="EEL-NOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="G2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INDALEX" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CABOTBER" b2="138 KV" b3="CAB-MAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="INDALEX" b2="138 KV" b3="IND-MAN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANORTAP" b2="138 KV" b3="MAN-NOR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NORTHLAN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NORTHLAN" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39030</SeqNum>
    <Name>L138.Ross-Clayburne-Delano</Name>
    <LastEdit Timestamp="2024-10-25T13:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYBURN" b2="138 KV" b3="CLA-DEL" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYBURN" b2="138 KV" b3="CLA-KEN" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYBURN" b2="138 KV" b3="CLA-ROS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELANO" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELANO" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENWORTH" b2="13.8 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KENWORTH" b2="13.8 KV" b3="LOAD22" />
      <ContingencyEquipment Action="X" Type="XF" b1="KENWORTH" b2="138 KV" b3="T2_XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="138 KV" b3="A2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39040</SeqNum>
    <Name>L138.Claytor-NorthClaytor</Name>
    <LastEdit Timestamp="2025-10-21T13:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CLAYTOR" b2="138 KV" b3=".  2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYTOR" b2="138 KV" b3="CLA-NCL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="11 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NCLAYTOR" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39050</SeqNum>
    <Name>L138.JamesRiver-Soapstone-Scottsville</Name>
    <LastEdit Timestamp="2025-05-30T10:17:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JAMESRV" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="JAMESRV" b2="138 KV" b3="JAM-SOAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOTTSVI" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCOTTSVI" b2="138 KV" b3="SCO-SOAP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOAPSTON" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39060</SeqNum>
    <Name>L138.Clinton-L48-Karl-Gesuper-Huntley</Name>
    <LastEdit Timestamp="2025-01-06T16:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTOCS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINTOCS" b2="138 KV" b3="CLI-L481" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTOCS" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="L" Type="LN" b1="GESUPER" b2="138 KV" b3="GES-HUN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GESUPER" b2="138 KV" b3="GES-L481" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GESUPER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTLEY2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KARL" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KARL" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="KARL" b2="138 KV" b3="KAR-L48" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39070</SeqNum>
    <Name>L138.TannersCreek-Drewersb-CollegeCorner</Name>
    <LastEdit Timestamp="2026-05-06T10:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLLEGEC" b2="138 KV" b3="COL-DRE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLEGEC" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLEGEC" b2="138 KV" b3="J2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DREWERSB" b2="138 KV" b3="DRE-TAN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DREWERSB" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39090</SeqNum>
    <Name>L138.OhioCentral-ConesvillePrep-Conesville</Name>
    <LastEdit Timestamp="2025-02-28T12:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CONEPREP" b2="138 KV" b3="CON-CON1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONEPREP" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="138 KV" b3="5C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="138 KV" b3="5S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="OHIOCENT" b2="138 KV" b3="OHI-CON1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39100</SeqNum>
    <Name>L138.Nportsmo-Cporstmo</Name>
    <LastEdit Timestamp="2026-05-06T10:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CPORTSMO" b2="138 KV" b3="CPO-NPO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPORTSMO" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPORTSMO" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39110</SeqNum>
    <Name>L138.Lockwood-Ctybryan</Name>
    <LastEdit Timestamp="2026-05-06T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CTYBRYAN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CTYBRYAN" b2="138 KV" b3="CTY-LOC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CTYBRYAN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CTYBRYAN" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKWOOD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOCKWOOD" b2="138 KV" b3="BBYP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39130</SeqNum>
    <Name>L138.Desoto-Perch-Jay</Name>
    <LastEdit Timestamp="2025-08-21T12:46:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DESOTO" b2="138 KV" b3="DES-PERC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JAY" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JAY" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="JAY" b2="138 KV" b3="JAY-PERC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PERCH" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERCH" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39140</SeqNum>
    <Name>L138.EWheelersburg-DogWoodRidge-Cotrell-Millbrook</Name>
    <LastEdit Timestamp="2024-05-17T10:23:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COTTRELL" b2="138 KV" b3="COT-MILL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COTTRELL" b2="138 KV" b3="H002J8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COTTRELL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COTTRELL" b2="138 KV" b3="COT-DOGW" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOGWOODR" b2="138 KV" b3="DOG-EWH1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOGWOODR" b2="138 KV" b3="DOG-MIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOGWOODR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWHEELER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLBROO" b2="138 KV" b3="K" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39150</SeqNum>
    <Name>L138.OhioCentral-Dresden + Dresden.CC</Name>
    <LastEdit Timestamp="2026-05-06T10:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="DRESDEN" b2="18 KV" b3="CT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DRESDEN" b2="18 KV" b3="CT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DRESDEN" b2="138 KV" b3="DRE-OHI" />
      <ContingencyEquipment Action="X" Type="XF" b1="DRESDEN" b2="138 KV" b3="GSU_CT1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DRESDEN" b2="138 KV" b3="GSU_CT2" />
      <ContingencyEquipment Action="X" Type="XF" b1="DRESDEN" b2="138 KV" b3="GSU_ST1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DRESDEN" b2="138 KV" b3="LOADSS1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DRESDEN" b2="138 KV" b3="LOADSS2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DRESDEN" b2="18 KV" b3="STM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="G2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39160</SeqNum>
    <Name>L138.EastLima-WestNewton-LynnSt-Skenton</Name>
    <LastEdit Timestamp="2025-08-07T11:45:17" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMA" b2="138 KV" b3="ELI-WNE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LYNNST" b2="138 KV" b3="LYN-SKE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LYNNST" b2="138 KV" b3="LYN-WNE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LYNNST" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKENTON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="URWNEWTN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="URWNEWTN" b2="138 KV" b3="URW-WNE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39170</SeqNum>
    <Name>L138.ELynchburg-JoshuaFalls</Name>
    <LastEdit Timestamp="2025-08-21T12:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELYNCHBU" b2="138 KV" b3="ELY-JOS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELYNCHBU" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOSHUAF2" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOSHUAF2" b2="138 KV" b3="J2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39180</SeqNum>
    <Name>L138.ELynchburg-OpossumCreek</Name>
    <LastEdit Timestamp="2025-08-13T13:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELYNCHBU" b2="138 KV" b3="ELY-OPO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELYNCHBU" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPOSSUMC" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPOSSUMC" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39190</SeqNum>
    <Name>L138.MuskingumRiver-ENewConcord-WestCambridge</Name>
    <LastEdit Timestamp="2026-05-05T09:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ENEWCONC" b2="138 KV" b3="ENE-WCA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ENEWCONC" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="138 KV" b3="HD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MUSKING2" b2="138 KV" b3="MUS-ENE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCAMBRI2" b2="138 KV" b3="A CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39210</SeqNum>
    <Name>L138.EWheeler-Texaseas</Name>
    <LastEdit Timestamp="2026-05-05T09:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EWHEELER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWHEELER" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="EWHEELER" b2="138 KV" b3="EWH-TEX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TEXASEAS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TEXASEAS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TEXASEAS" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39220</SeqNum>
    <Name>L138.EastWooster-MineralSprings-AppleAve</Name>
    <LastEdit Timestamp="2025-03-10T14:43:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="APPLEAVE" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="APPLEAVE" b2="138 KV" b3="APP-MINE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="APPLEAVE" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="EWOOSTER" b2="138 KV" b3="EWO-MINE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWOOSTER" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINERALS" b2="138 KV" b3="GENCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MINERALS" b2="138 KV" b3="GENDUMMY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39230</SeqNum>
    <Name>L138.SCanton-Faircrest-SECanton</Name>
    <LastEdit Timestamp="2026-05-05T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FAIRCRES" b2="138 KV" b3="FAI-SCA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAIRCRES" b2="138 KV" b3="FAI-SEC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FAIRCRES" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="N1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39240</SeqNum>
    <Name>L138.FallCreek-NewCastle</Name>
    <LastEdit Timestamp="2025-02-26T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FALLCREE" b2="138 KV" b3="FAL-NEW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLCREE" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLCREE" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCAST2" b2="138 KV" b3="05" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39250</SeqNum>
    <Name>L138.Fieldale-WBassett</Name>
    <LastEdit Timestamp="2025-06-25T14:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FIELDALE" b2="138 KV" b3="FIE-WBA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDALE" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="X" Type="XF" b1="WBASSETT" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="WBASSETT" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="WBASSETT" b2="34.5 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBASSETT" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBASSETT" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WBASSETT" b2="34.5 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39260</SeqNum>
    <Name>L138.Fisher-L22-Hall-Wilsoncs</Name>
    <LastEdit Timestamp="2026-05-06T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FISHER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="FISHER" b2="138 KV" b3="FIS-L221" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FISHER" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HALL" b2="138 KV" b3="HAL-L221" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HALL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HALL" b2="138 KV" b3="TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="L22" b2="138 KV" b3="L22-WIL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONCS" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONCS" b2="138 KV" b3="7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39270</SeqNum>
    <Name>L138.GardenCreek-Halesbranch</Name>
    <LastEdit Timestamp="2026-05-08T15:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GARDENCR" b2="138 KV" b3="GAR-HAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARDENCR" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HALESBRA" b2="69 KV" b3="A008T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HALESBRA" b2="69 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HALESBRA" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HALESBRA" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HALESBRA" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HALESBRA" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHACKMIL" b2="138 KV" b3="HAL-SHA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HALESBRA" b2="12 KV" b3="LOAD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HALESBRA" b2="138 KV" b3="P-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HALESBRA" b2="69 KV" b3="S-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HALESBRA" b2="69 KV" b3="SMOKELES" />
      <ContingencyEquipment Action="X" Type="XF" b1="HALESBRA" b2="12 KV" b3="T-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HALESBRA" b2="138 KV" b3="XT1 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39280</SeqNum>
    <Name>L138.Grangston-BSpeaker + BSpeaker.Units</Name>
    <LastEdit Timestamp="2025-11-18T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="BSPEAKER" b2="13.8 KV" b3="1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BSPEAKER" b2="13.8 KV" b3="2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BSPEAKER" b2="13.8 KV" b3="3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BSPEAKER" b2="13.8 KV" b3="4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BSPEAKER" b2="13.8 KV" b3="5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BSPEAKER" b2="13.8 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BSPEAKER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BSPEAKER" b2="138 KV" b3="LOADSS" />
      <ContingencyEquipment Action="X" Type="XF" b1="BSPEAKER" b2="138 KV" b3="T01" />
      <ContingencyEquipment Action="X" Type="XF" b1="BSPEAKER" b2="138 KV" b3="T02" />
      <ContingencyEquipment Action="X" Type="XF" b1="BSPEAKER" b2="138 KV" b3="T03" />
      <ContingencyEquipment Action="X" Type="XF" b1="BSPEAKER" b2="13.8 KV" b3="T11" />
      <ContingencyEquipment Action="X" Type="XF" b1="BSPEAKER" b2="13.8 KV" b3="T12" />
      <ContingencyEquipment Action="X" Type="XF" b1="BSPEAKER" b2="13.8 KV" b3="T21" />
      <ContingencyEquipment Action="X" Type="XF" b1="BSPEAKER" b2="13.8 KV" b3="T22" />
      <ContingencyEquipment Action="X" Type="XF" b1="BSPEAKER" b2="13.8 KV" b3="T31" />
      <ContingencyEquipment Action="X" Type="XF" b1="BSPEAKER" b2="13.8 KV" b3="T32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANGSTO" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANGSTO" b2="138 KV" b3="GRA-BSP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39300</SeqNum>
    <Name>L138.Whitewood-ShackMills-HalesBranch</Name>
    <LastEdit Timestamp="2026-05-06T10:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HALESBRA" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHACKMIL" b2="138 KV" b3="CONSOLCO" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHACKMIL" b2="138 KV" b3="HAL-SHA" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHACKMIL" b2="138 KV" b3="SHA-WHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEWD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEWD" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39310</SeqNum>
    <Name>L138.Hangrock-HRTap-E.Wheelersburg-Bellefonte</Name>
    <LastEdit Timestamp="2024-11-20T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEFON" b2="138 KV" b3="W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWHEELER" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="X" Type="XF" b1="HANGROCK" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="HANGROCK" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANGROCK" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANGROCK" b2="138 KV" b3="HAN-HAN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HANGROCK" b2="34 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLEFON" b2="138 KV" b3="BEL-HAN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EWHEELER" b2="138 KV" b3="EWH-HAN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39320</SeqNum>
    <Name>L138.Scippo-Hargus</Name>
    <LastEdit Timestamp="2026-05-05T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HARGUS" b2="138 KV" b3="HAR-SCI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARGUS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCIPPO" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCIPPO" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39330</SeqNum>
    <Name>L138.SPrinceton-Hatcher-GlenLyn</Name>
    <LastEdit Timestamp="2024-09-26T16:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENLYN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="HALLSRID" b2="138 KV" b3="HAL-HAT" />
      <ContingencyEquipment Action="L" Type="LN" b1="HALLSRID" b2="138 KV" b3="HAL-SPR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HALLSRID" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HATCHER" b2="138 KV" b3="HAT-GLE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HATCHER" b2="138 KV" b3="HAT-SPE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPEEDWAY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINCET" b2="138 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39340</SeqNum>
    <Name>L138.HazelHollow-Inglesst</Name>
    <LastEdit Timestamp="2026-05-05T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZELHOL" b2="138 KV" b3="138" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAZELHOL" b2="138 KV" b3="HAZ-ING1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INGLESST" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39360</SeqNum>
    <Name>L138.Hillsboro-WildCat</Name>
    <LastEdit Timestamp="2025-11-10T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSBOR" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSBOR" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSBOR" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLSBOR" b2="138 KV" b3="HIL-WIL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILDCAT" b2="138 KV" b3="A-CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILDCAT" b2="138 KV" b3="H001M2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39370</SeqNum>
    <Name>L138.Hillsboro-Sinkings-Millbrook</Name>
    <LastEdit Timestamp="2026-05-05T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSBOR" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSBOR" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLSBOR" b2="138 KV" b3="HIL-SIN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLBROO" b2="138 KV" b3="MIL-SIN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLBROO" b2="138 KV" b3="O" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SINKINGS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39380</SeqNum>
    <Name>L138.Holston-BooneDam (Tie)</Name>
    <LastEdit Timestamp="2025-06-25T14:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BOONEHYD" b2="138 KV" b3="921" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONEHYD" b2="138 KV" b3="924" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLSTON" b2="138 KV" b3="HOL-BOO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLSTON" b2="138 KV" b3="T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39390</SeqNum>
    <Name>L138.Holston-Riggs-Sullgard</Name>
    <LastEdit Timestamp="2024-11-08T13:13:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLSTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLSTON" b2="138 KV" b3="HOL-RIG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIGGS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SULLGARD" b2="138 KV" b3="CAPAA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLGARD" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIGGS" b2="138 KV" b3="RIG-SUL" />
      <ContingencyEquipment Action="L" Type="LN" b1="SULLGARD" b2="138 KV" b3="SUL-WAL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SULLGARD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALTERS" b2="138 KV" b3="3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39400</SeqNum>
    <Name>DTX.Holston.T7</Name>
    <LastEdit Timestamp="2024-05-06T09:00:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOLSTON" b2="138 KV" b3="T7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLSTON" b2="138 KV" b3="XT7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39410</SeqNum>
    <Name>DTX138.Holston.T6</Name>
    <LastEdit Timestamp="2024-06-10T15:21:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLSTON" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLSTON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLSTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HOLSTON" b2="138 KV" b3="CAPB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLSTON" b2="138 KV" b3="HOL-TEN2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOLSTON" b2="138 KV" b3="T6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLSTON" b2="138 KV" b3="V" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TENNESSE" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TENNESSE" b2="138 KV" b3="TC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TENNESSE" b2="138 KV" b3="TE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39420</SeqNum>
    <Name>L138.Howard-Shelbyop.1</Name>
    <LastEdit Timestamp="2026-05-06T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOWARD2" b2="138 KV" b3="HOW-SHE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBYOP" b2="138 KV" b3="GH1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39430</SeqNum>
    <Name>L138.Wkingsport-Industry</Name>
    <LastEdit Timestamp="2025-11-14T13:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="INDUSTRY" b2="138 KV" b3="IND-WKI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INDUSTRY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INDUSTRY" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WKINGSPO" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WKINGSPO" b2="138 KV" b3="P1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39440</SeqNum>
    <Name>L138.HummelCrk-Rockcrk-Huntingt-Sorenson</Name>
    <LastEdit Timestamp="2025-09-12T13:05:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELCR" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUMMELCR" b2="138 KV" b3="HUM-ROC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTINGT" b2="138 KV" b3="HUN-HUN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTINGT" b2="138 KV" b3="HUN-SOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTIPSI" b2="138 KV" b3="12-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTIPSI" b2="138 KV" b3="17-B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTIPSI" b2="138 KV" b3="B2-17" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUNTIPSI" b2="138 KV" b3="BK3LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKCREE" b2="138 KV" b3="ROC-HUN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKCREE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="L2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39450</SeqNum>
    <Name>L138.Huntley-Linworth</Name>
    <LastEdit Timestamp="2026-05-06T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTLEY2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTLEY2" b2="138 KV" b3="HUN-LIN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINWORTH" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINWORTH" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39460</SeqNum>
    <Name>L138.Mullens-Itmann-Pinacle-MullVil-Guyandot-Wyomg</Name>
    <LastEdit Timestamp="2025-11-03T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GUYANDOT" b2="138 KV" b3="GUY-MUL" />
      <ContingencyEquipment Action="L" Type="LN" b1="GUYANDOT" b2="138 KV" b3="GUY-WYO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GUYANDOT" b2="138 KV" b3="LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GUYANDOT" b2="138 KV" b3="MARIANNA" />
      <ContingencyEquipment Action="L" Type="LN" b1="ITMANN" b2="138 KV" b3="ITM-MUL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ITMANN" b2="138 KV" b3="ITM-PIN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ITMANN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MULLENS" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="L" Type="LN" b1="MULLENSV" b2="138 KV" b3="MUL-PIN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MULLENSV" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PINNACLE" b2="138 KV" b3="T1A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PINNACLE" b2="138 KV" b3="T1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="138 KV" b3="F1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39470</SeqNum>
    <Name>L138.Johnscreek-Stone</Name>
    <LastEdit Timestamp="2025-01-30T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSCRE" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSCRE" b2="138 KV" b3="JOH-STO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STONE" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39480</SeqNum>
    <Name>L138.JoshuaFalls-OpossumCreek</Name>
    <LastEdit Timestamp="2025-09-02T10:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOSHUAF2" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOSHUAF2" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOSHUAF2" b2="138 KV" b3="JOS-OPO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPOSSUMC" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPOSSUMC" b2="138 KV" b3="A2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39490</SeqNum>
    <Name>L138.Gavin-Lakin</Name>
    <LastEdit Timestamp="2025-10-21T13:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="138 KV" b3="AE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="138 KV" b3="AE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKIN" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKIN" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKIN" b2="138 KV" b3="LAK-GAV1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39500</SeqNum>
    <Name>L138.Kammer-Hannibal.1</Name>
    <LastEdit Timestamp="2025-05-12T14:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNIBAL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNIBAL" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANNIBAL" b2="138 KV" b3="HAN-KAM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="I CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="I2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39510</SeqNum>
    <Name>L138.Kammer-Hannibal.2</Name>
    <LastEdit Timestamp="2025-05-15T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNIBAL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNIBAL" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="H CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="H2 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANNIBAL" b2="138 KV" b3="HAN-KAM2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39520</SeqNum>
    <Name>L138.Kammer-Hannibal.3</Name>
    <LastEdit Timestamp="2025-05-15T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNIBAL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNIBAL" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="G CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="G2 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANNIBAL" b2="138 KV" b3="HAN-KAM3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39550</SeqNum>
    <Name>L138.Mierpsi-Mier</Name>
    <LastEdit Timestamp="2026-05-08T11:32:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MIER" b2="138 KV" b3="MIE-MIE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIER" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MIERPSI" b2="138 KV" b3="LABM_DS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39560</SeqNum>
    <Name>L138.SPrinceton-Newhope-Minnixmt-Switchback</Name>
    <LastEdit Timestamp="2026-05-07T14:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MINNIXMT" b2="138 KV" b3="MIN-NEW1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MINNIXMT" b2="138 KV" b3="MIN-SWI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MINNIXMT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MINNIXMT" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWHOPE2" b2="138 KV" b3="NEW-SPR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWHOPE2" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWHOPE2" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINCET" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWITCHBA" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39580</SeqNum>
    <Name>L138.Mulberry-Rozelle-BlaineSCP-Waverly</Name>
    <LastEdit Timestamp="2026-05-08T15:10:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLAINSCP" b2="138 KV" b3="BLA-ROZE" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLAINSCP" b2="138 KV" b3="BLA-WAVE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLAINSCP" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MULBERRY" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="MULBERRY" b2="138 KV" b3="MUL-ROZ" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROZELLE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY2" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY2" b2="138 KV" b3="102" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39600</SeqNum>
    <Name>L138.Natrium-Pittspla</Name>
    <LastEdit Timestamp="2026-05-06T10:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="NATRIUM2" b2="138 KV" b3="NAT-PIT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PITTSPLA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PITTSPLA" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39610</SeqNum>
    <Name>L138.NBristol-Bristol(TVA)</Name>
    <LastEdit Timestamp="2025-08-22T11:56:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NBRIST" b2="138 KV" b3="834" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBRIST" b2="138 KV" b3="854" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NBRIST" b2="138 KV" b3="T1_3BVU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBRISTOL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBRISTOL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="NBRISTOL" b2="138 KV" b3="NBR-NBR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39620</SeqNum>
    <Name>L138.OpossumCreek-Peaksview</Name>
    <LastEdit Timestamp="2026-05-06T10:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OPOSSUMC" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPOSSUMC" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="OPOSSUMC" b2="138 KV" b3="OPO-PEA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEAKSVIE" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEAKSVIE" b2="34 KV" b3="LOAD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEAKSVIE" b2="138 KV" b3="T1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEAKSVIE" b2="69 KV" b3="T1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEAKSVIE" b2="34 KV" b3="T1-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39630</SeqNum>
    <Name>L138.Tenmile-Redwarri</Name>
    <LastEdit Timestamp="2026-05-07T14:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="REDWARRI" b2="138 KV" b3="RED-TEN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REDWARRI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TENMILE" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39640</SeqNum>
    <Name>L138.Ridgeway-DanRiver</Name>
    <LastEdit Timestamp="2025-12-03T16:22:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DANRIV" b2="138 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGEWAY" b2="138 KV" b3="A002D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIDGEWAY" b2="138 KV" b3="RID-DAN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39650</SeqNum>
    <Name>L138.WestMillersport-SouthBaltimore</Name>
    <LastEdit Timestamp="2026-05-08T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SBALTIMO" b2="138 KV" b3="A CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="SBALTIMO" b2="138 KV" b3="SBA-WMI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="138 KV" b3="C1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39660</SeqNum>
    <Name>L138.Rutland-Belleville</Name>
    <LastEdit Timestamp="2026-05-07T14:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEVI2" b2="138 KV" b3="RUTL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUTLAND" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUTLAND" b2="138 KV" b3="RUT-BEL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39680</SeqNum>
    <Name>L138.SECanton-Sunnyside</Name>
    <LastEdit Timestamp="2026-05-07T14:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SECANTON" b2="138 KV" b3="SEC-SUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNNYSOP" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39690</SeqNum>
    <Name>L138.Argentum-SouthPortsmouth-Millbrook</Name>
    <LastEdit Timestamp="2026-01-02T11:18:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGNT_EK" b2="138 KV" b3="CB824" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ARGNT_EK" b2="138 KV" b3="SW827" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLBROO" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLBROO" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPORTSMO" b2="138 KV" b3="SPO-ARG1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPORTSMO" b2="138 KV" b3="SPO-MIL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPORTSMO" b2="138 KV" b3="SPO-VAN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VANCEBUR" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VANCEBUR" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39700</SeqNum>
    <Name>L138.BlueRacer-Texasber</Name>
    <LastEdit Timestamp="2024-09-19T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLUERACE" b2="138 KV" b3="BLU-TEX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUERACE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TEXASBER" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39710</SeqNum>
    <Name>L138.Tidd-WheelingSteel.2</Name>
    <LastEdit Timestamp="2026-05-08T15:16:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TIDD_AEP" b2="138 KV" b3="TID-WHE2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WHEELSTE" b2="138 KV" b3="DUME1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHEELSTE" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39720</SeqNum>
    <Name>L138.Tidd-WheelingSteel.1</Name>
    <LastEdit Timestamp="2026-05-07T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TIDD_AEP" b2="138 KV" b3="TID-WHE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39740</SeqNum>
    <Name>L138.CollegeCorner-Trenton-Hutching</Name>
    <LastEdit Timestamp="2025-04-15T13:56:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLEGEC" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLEGEC" b2="138 KV" b3="L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="138 KV" b3="AA-D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRENTON2" b2="138 KV" b3="TB2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRENTON2" b2="138 KV" b3="TRE-COL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRENTON2" b2="138 KV" b3="TRE-HUT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39750</SeqNum>
    <Name>L138.Tristate-Marriett-TwelvePole</Name>
    <LastEdit Timestamp="2025-04-21T15:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MARRIETT" b2="138 KV" b3="MAR-TRI" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARRIETT" b2="138 KV" b3="MAR-TWE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARRIETT" b2="138 KV" b3="XB1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARRIETT" b2="138 KV" b3="XB1H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARRIETT" b2="138 KV" b3="XB2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARRIETT" b2="138 KV" b3="XB2H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TWELVEPO" b2="13 KV" b3="1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TWELVEPO" b2="13 KV" b3="2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TWELVEPO" b2="13 KV" b3="3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TWELVEPO" b2="13 KV" b3="4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TWELVEPO" b2="13 KV" b3="5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TWELVEPO" b2="13 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWELVEPO" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWELVEPO" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWELVEPO" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39760</SeqNum>
    <Name>L138.Turner-Unioncam</Name>
    <LastEdit Timestamp="2026-05-08T15:16:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="F1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TURNER" b2="138 KV" b3="TUR-UNI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIONCAM" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIONCAM" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39770</SeqNum>
    <Name>L138.Unioncam-Unionca8</Name>
    <LastEdit Timestamp="2026-05-08T15:21:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIONCA8" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIONCA8" b2="138 KV" b3="LT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="UNIONCA8" b2="138 KV" b3="UNI-UNI2" />
      <ContingencyEquipment Action="S" Type="SD" b1="UNIONCA8" b2="138 KV" b3="UNIONCA8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIONCAM" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIONCAM" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39780</SeqNum>
    <Name>L138.Vine-City.1</Name>
    <LastEdit Timestamp="2026-05-08T10:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CITY" b2="138 KV" b3="AD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="106" />
      <ContingencyEquipment Action="L" Type="LN" b1="VINE" b2="138 KV" b3="VIN-CIT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39790</SeqNum>
    <Name>L138.Vine-City.2</Name>
    <LastEdit Timestamp="2026-05-08T15:05:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CITY" b2="138 KV" b3="AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="107" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="VINE" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="H024E8" />
      <ContingencyEquipment Action="L" Type="LN" b1="VINE" b2="138 KV" b3="VIN-CIT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39800</SeqNum>
    <Name>L138.Wolfhill-Constell + Constell.U1&amp;2</Name>
    <LastEdit Timestamp="2026-03-06T09:46:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CONSTELL" b2="13.8 KV" b3="1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONSTELL" b2="13.8 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONSTELL" b2="138 KV" b3="L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFHILL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFHILL" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="WOLFHILL" b2="138 KV" b3="WOL-CON2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39810</SeqNum>
    <Name>L138.Wolfhill-Constell.1 + Constell.U3&amp;4&amp;5</Name>
    <LastEdit Timestamp="2026-03-05T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CONSTELL" b2="13.8 KV" b3="3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONSTELL" b2="13.8 KV" b3="4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONSTELL" b2="13.8 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONSTELL" b2="138 KV" b3="L1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFHILL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFHILL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="WOLFHILL" b2="138 KV" b3="WOL-CON1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39820</SeqNum>
    <Name>L138.Wyoming-W.Welch-Jimbranch</Name>
    <LastEdit Timestamp="2026-05-08T10:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JIMBRANC" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WELCH" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WWELCH" b2="138 KV" b3="WWE-JIM1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WWELCH" b2="138 KV" b3="WWE-WEL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WWELCH" b2="138 KV" b3="WWE-WYO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="138 KV" b3="J1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39830</SeqNum>
    <Name>L138.Jimbranch-Gary-Thrope-Switchback</Name>
    <LastEdit Timestamp="2024-09-26T16:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GARY" b2="138 KV" b3="GAR-THO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GARY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JIMBRANC" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARY" b2="138 KV" b3="GAR-JIM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWITCHBA" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="SWITCHBA" b2="138 KV" b3="SWI-THO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THORPE" b2="138 KV" b3="THORPE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39840</SeqNum>
    <Name>L115.Harmony-Wan.176</Name>
    <LastEdit Timestamp="2026-03-02T11:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONYV" b2="115 KV" b3="17662" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARMONYV" b2="115 KV" b3="176A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WAN" b2="115 KV" b3="89T176" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAN" b2="115 KV" b3="H122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAN" b2="115 KV" b3="H222" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39860</SeqNum>
    <Name>L115.KittyHawk-Colington-Nagshead-OregonInlet.52</Name>
    <LastEdit Timestamp="2024-12-17T15:55:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLINGTN" b2="115 KV" b3="52B" />
      <ContingencyEquipment Action="S" Type="SD" b1="COLINGTN" b2="115 KV" b3="52Z" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="COLINGTN" b2="115 KV" b3="SC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLINGTN" b2="115 KV" b3="SV132" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLINGTN" b2="115 KV" b3="52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="115 KV" b3="5252" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="115 KV" b3="L2T52" />
      <ContingencyEquipment Action="L" Type="LN" b1="NAGSHEAD" b2="115 KV" b3="190A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGSHEAD" b2="115 KV" b3="52T190" />
      <ContingencyEquipment Action="X" Type="XF" b1="NAGSHEAD" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NAGSHEAD" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="NAGSHEAD" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NAGSHEAD" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OREGONDP" b2="115 KV" b3="DP1CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39870</SeqNum>
    <Name>L115.CannonBranch-Dominion-LomarDP.197</Name>
    <LastEdit Timestamp="2025-08-25T18:04:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CANNONBR" b2="115 KV" b3="163T197" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANNONBR" b2="115 KV" b3="197A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANNONBR" b2="115 KV" b3="L1T197" />
      <ContingencyEquipment Action="S" Type="SD" b1="DOMINDP" b2="115 KV" b3="197A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOMARDP" b2="115 KV" b3="197B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOMINDP" b2="115 KV" b3="LD0" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOMINDP" b2="115 KV" b3="LD2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOMARDP" b2="115 KV" b3="172T197" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOMARDP" b2="115 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39880</SeqNum>
    <Name>L115.Chancellor-NiRiver-Golddale-Spotsylvania.198</Name>
    <LastEdit Timestamp="2025-03-17T14:22:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="NIRIVER" b2="115 KV" b3="198E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHANCELR" b2="115 KV" b3="H2T198" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHANCELR" b2="115 KV" b3="H3T198" />
      <ContingencyEquipment Action="L" Type="LN" b1="TODDSTVN" b2="115 KV" b3="198D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NIRIVER" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="115 KV" b3="19872" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="115 KV" b3="37T198" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPOTSLV" b2="115 KV" b3="GOL-SPOT" />
      <ContingencyEquipment Action="L" Type="LN" b1="TODDSTVN" b2="115 KV" b3="198C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TODDSTVN" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TODDSTVN" b2="115 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39890</SeqNum>
    <Name>L230.Lynnhaven-VirginiaBeach.2072</Name>
    <LastEdit Timestamp="2026-05-08T10:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNNHAVN" b2="230 KV" b3="20262072" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNNHAVN" b2="230 KV" b3="207282" />
      <ContingencyEquipment Action="L" Type="LN" b1="LYNNHAVN" b2="230 KV" b3="2072A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="230 KV" b3="H5T2072" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="230 KV" b3="H6T2072" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39900</SeqNum>
    <Name>L115.Basin-Marlboro-Dupont.21</Name>
    <LastEdit Timestamp="2026-05-07T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASIN" b2="115 KV" b3="2142" />
      <ContingencyEquipment Action="L" Type="LN" b1="BASIN" b2="115 KV" b3="21A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPONT4" b2="115 KV" b3="2162" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUPONT4" b2="115 KV" b3="21B" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARLBORO" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARLBORO" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARLBORO" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARLBORO" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39910</SeqNum>
    <Name>L115.BalconyFalls-Cushaw.28 + Cushaw.U15</Name>
    <LastEdit Timestamp="2025-05-30T13:10:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CUSHAW" b2="115 KV" b3="28A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALCFALL" b2="115 KV" b3="28T141CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALCFALL" b2="115 KV" b3="9T28CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CUSHAW" b2="2 KV" b3="G15" />
      <ContingencyEquipment Action="X" Type="XF" b1="CUSHAW" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CUSHAW" b2="115 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39920</SeqNum>
    <Name>L115.SedgeHill-Sinai-SouthBoston-Welco.32</Name>
    <LastEdit Timestamp="2024-09-27T08:18:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="REEDYCRK" b2="115 KV" b3="32T127" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEDGEHIL" b2="115 KV" b3="32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="115 KV" b3="3202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="115 KV" b3="WT32" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOBOSTON" b2="115 KV" b3="32C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SINAI" b2="115 KV" b3="H262" />
      <ContingencyEquipment Action="X" Type="XF" b1="SINAI" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SINAI" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SINAI" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SINAI" b2="13 KV" b3="TX2_LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOBOSTON" b2="115 KV" b3="32A1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SOBOSTON" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOBOSTON" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SOBOSTON" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOBOSTON" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="WELCO" b2="115 KV" b3="32D1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WELCO" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WELCO" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WELCO" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WELCO" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WELCO" b2="35 KV" b3="WATLNGSP" />
      <ContingencyEquipment Action="L" Type="LN" b1="REEDYCRK" b2="115 KV" b3="32E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39930</SeqNum>
    <Name>L115.ChaseCity-NorthView-SouthHill-Lacrosse.40</Name>
    <LastEdit Timestamp="2025-11-07T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHASECTY" b2="115 KV" b3="4012" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHASECTY" b2="115 KV" b3="40A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACROSSE" b2="115 KV" b3="4022" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACROSSE" b2="115 KV" b3="H1T40" />
      <ContingencyEquipment Action="L" Type="LN" b1="LACROSSE" b2="115 KV" b3="LAC-SOUT" />
      <ContingencyEquipment Action="L" Type="LN" b1="NVIEWDP" b2="115 KV" b3="40B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NVIEWDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SOUTHILL" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOUTHILL" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SOUTHILL" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOUTHILL" b2="13 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39940</SeqNum>
    <Name>L115.Chesapeake-DeepCreek-Yadkin.46</Name>
    <LastEdit Timestamp="2025-06-24T13:10:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="115 KV" b3="4622" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHESAPKE" b2="115 KV" b3="4628" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESAPKE" b2="115 KV" b3="46B" />
      <ContingencyEquipment Action="L" Type="LN" b1="YADKIN4" b2="115 KV" b3="46C" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DEEPCREK" b2="115 KV" b3="8737" />
      <ContingencyEquipment Action="X" Type="XF" b1="DEEPCREK" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DEEPCREK" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DEEPCREK" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DEEPCREK" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="115 KV" b3="L3T46" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="115 KV" b3="L6T46" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39960</SeqNum>
    <Name>L115.Bremo-TricesLake-CobsCr-JamesRiver-Columbia.4</Name>
    <LastEdit Timestamp="2024-10-02T14:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="115 KV" b3="422" />
      <ContingencyEquipment Action="L" Type="LN" b1="BREMO4" b2="115 KV" b3="4A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BREMO4" b2="115 KV" b3="4T5" />
      <ContingencyEquipment Action="S" Type="SD" b1="BREMO4" b2="115 KV" b3="4Z" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COBBSCRK" b2="115 KV" b3="DP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLUMBI4" b2="115 KV" b3="COL-JAM1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COLUMBI4" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COBBSCRK" b2="115 KV" b3="COB-JAME" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JAMESRIV" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRICESLK" b2="115 KV" b3="4A2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRICESLK" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COBBSCRK" b2="115 KV" b3="COB-TRIC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39970</SeqNum>
    <Name>L115.Gosport-Berkley-ReevesAvenue.51</Name>
    <LastEdit Timestamp="2026-05-07T14:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BERKLEY" b2="115 KV" b3="51A" />
      <ContingencyEquipment Action="L" Type="LN" b1="REEVESAV" b2="115 KV" b3="51B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERKLEY" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERKLEY" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOSPORT" b2="115 KV" b3="5172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="115 KV" b3="5112" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39980</SeqNum>
    <Name>L115.Ellmont-GreenWDP.59</Name>
    <LastEdit Timestamp="2026-05-07T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="115 KV" b3="5992" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMONT4" b2="115 KV" b3="59A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELMONT4" b2="115 KV" b3="59T142" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENWDP" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>39990</SeqNum>
    <Name>L115.Bremo-ForkUnion.5</Name>
    <LastEdit Timestamp="2024-11-05T09:57:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BREMO4" b2="115 KV" b3="4T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="115 KV" b3="522" />
      <ContingencyEquipment Action="L" Type="LN" b1="BREMO4" b2="115 KV" b3="BRE-FRKU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRKUNION" b2="115 KV" b3="572" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRKUNION" b2="115 KV" b3="ZT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40000</SeqNum>
    <Name>L115.Locks-Reams-Sapony-Purdy.69</Name>
    <LastEdit Timestamp="2025-05-13T14:54:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKS" b2="115 KV" b3="6922" />
      <ContingencyEquipment Action="L" Type="LN" b1="REAMSDP" b2="115 KV" b3="69C" />
      <ContingencyEquipment Action="L" Type="LN" b1="PURDY" b2="115 KV" b3="69A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PURDY" b2="115 KV" b3="69T148" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAPONY" b2="115 KV" b3="69B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REAMSDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SAPONY" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SAPONY" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40010</SeqNum>
    <Name>L115.ClubHouse-Freeman-Lawrence-Brunsck-Brodnax.71</Name>
    <LastEdit Timestamp="2026-03-30T18:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNSWCK" b2="115 KV" b3="71B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRODNAX" b2="115 KV" b3="71T1064" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRODNAX" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRODNAX" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWCK" b2="69 KV" b3="13292" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNSWCK" b2="69 KV" b3="132A" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAWRNCVL" b2="115 KV" b3="71C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BRUNSWCK" b2="115 KV" b3="SC1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNSWCK" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLBHOUSE" b2="115 KV" b3="7152" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLBHOUSE" b2="115 KV" b3="71E" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CLBHOUSE" b2="115 KV" b3="SC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DANLTNDP" b2="69 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAWRNCVL" b2="115 KV" b3="71D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FREEMNDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GASBRGDP" b2="69 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAWRNCVL" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAWRNCVL" b2="34.5 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAWRNCVL" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAWRNCVL" b2="34.5 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40020</SeqNum>
    <Name>L115.Whealton-CopelandPark.75</Name>
    <LastEdit Timestamp="2025-03-17T13:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NWPORTNW" b2="115 KV" b3="7522" />
      <ContingencyEquipment Action="L" Type="LN" b1="NWPORTNW" b2="115 KV" b3="NWP-WHEA" />
      <ContingencyEquipment Action="X" Type="XF" b1="NWPORTNW" b2="115 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NWPORTNW" b2="13 KV" b3="TX4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEALTON" b2="115 KV" b3="7542" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40030</SeqNum>
    <Name>L138.Hydramatic-Corey</Name>
    <LastEdit Timestamp="2024-10-25T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COREY" b2="138 KV" b3="COR-HYD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COREY" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COREY" b2="138 KV" b3="K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYDRAMAT" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HYDRAMAT" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40040</SeqNum>
    <Name>L115.Everetts-Wharton-WashngtDp-LeggettsCrossRd.82</Name>
    <LastEdit Timestamp="2025-07-01T11:49:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERETTS" b2="115 KV" b3="8212" />
      <ContingencyEquipment Action="L" Type="LN" b1="WHARTON4" b2="115 KV" b3="82A" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEGXRDDP" b2="115 KV" b3="LEG-WASH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEGXRDDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WASHNTDP" b2="115 KV" b3="82B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHARTON4" b2="115 KV" b3="82T189" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WHARTON4" b2="115 KV" b3="SC2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40050</SeqNum>
    <Name>L115.Staunton-Craigsville.83</Name>
    <LastEdit Timestamp="2026-05-08T10:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CRAIGSVL" b2="115 KV" b3="10T83" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRIMBLDP" b2="115 KV" b3="83A" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRIMBLDP" b2="115 KV" b3="83B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAUNTON" b2="115 KV" b3="H5T83" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAUNTON" b2="115 KV" b3="L6T83" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRIMBLDP" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40060</SeqNum>
    <Name>L115.Farmville-WillisMount-Pamplin.84</Name>
    <LastEdit Timestamp="2025-03-17T14:15:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CURDSVDP" b2="115 KV" b3="149A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CURDSVDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="115 KV" b3="8432" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMVILL" b2="115 KV" b3="84A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAMPLIN" b2="115 KV" b3="8442" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAMPLIN" b2="115 KV" b3="84B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAMPLIN" b2="115 KV" b3="84T154" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLISMT" b2="115 KV" b3="14922" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40070</SeqNum>
    <Name>L115.Churchland-Chesapeake.87</Name>
    <LastEdit Timestamp="2026-05-07T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOWERSHL" b2="115 KV" b3="144A" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALEXANDC" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALEXANDC" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWERSHL" b2="115 KV" b3="14432" />
      <ContingencyEquipment Action="L" Type="LN" b1="HODGESFY" b2="115 KV" b3="87B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOWERSHL" b2="115 KV" b3="87C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="115 KV" b3="8722" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHESAPKE" b2="115 KV" b3="8728" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESAPKE" b2="115 KV" b3="87D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRCHLND" b2="115 KV" b3="8752" />
      <ContingencyEquipment Action="L" Type="LN" b1="HODGESFY" b2="115 KV" b3="87A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DEEPCREK" b2="115 KV" b3="8737" />
      <ContingencyEquipment Action="X" Type="XF" b1="HODGESFY" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HODGESFY" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HODGESFY" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HODGESFY" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40080</SeqNum>
    <Name>L115.Acca-Hermtage-Carver.88</Name>
    <LastEdit Timestamp="2026-05-07T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ACCA" b2="115 KV" b3="8872" />
      <ContingencyEquipment Action="L" Type="LN" b1="ACCA" b2="115 KV" b3="88A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARVER" b2="115 KV" b3="8862" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARVER" b2="115 KV" b3="88B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HERMTAGE" b2="13.2 KV" b3="LOAD 3" />
      <ContingencyEquipment Action="X" Type="XF" b1="HERMTAGE" b2="115 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40090</SeqNum>
    <Name>L115.HarmonyVillage-Hayes.89+230/115.Hayes.TX3</Name>
    <LastEdit Timestamp="2026-05-07T14:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONYV" b2="115 KV" b3="8962" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAN" b2="115 KV" b3="89A" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAYES" b2="115 KV" b3="89C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES" b2="115 KV" b3="L342" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAYES" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAYES" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAYES" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAYES" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAYES" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAN" b2="115 KV" b3="89B1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WAN" b2="115 KV" b3="89T176" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40120</SeqNum>
    <Name>L115.Skimmer(AEP)-Skimmer(DOM)</Name>
    <LastEdit Timestamp="2025-05-19T15:03:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SKIMMER" b2="115 KV" b3="1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SKIMMER" b2="115 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKIMMER" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKIMMER" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="SKIMMER" b2="115 KV" b3="SKI-3DO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SKIMMER" b2="115 KV" b3="SKI-BAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKIMMER4" b2="115 KV" b3="14162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKIMMER4" b2="115 KV" b3="3062" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40140</SeqNum>
    <Name>L69.Pentagon-Rosslyn.178</Name>
    <LastEdit Timestamp="2024-12-31T13:49:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="69 KV" b3="17822" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENTAGON" b2="69 KV" b3="178A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="69 KV" b3="178T186" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSLYN" b2="69 KV" b3="122T178" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSLYN" b2="69 KV" b3="174T178" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROSLYN" b2="13 KV" b3="TX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROSLYN" b2="69 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40150</SeqNum>
    <Name>DTX69.Rosslyn.TX2</Name>
    <LastEdit Timestamp="2024-12-31T13:49:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSLYN" b2="69 KV" b3="143T179" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSLYN" b2="69 KV" b3="179T180" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROSLYN" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROSLYN" b2="69 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40170</SeqNum>
    <Name>L69.Pentagon-War.186</Name>
    <LastEdit Timestamp="2026-05-11T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="69 KV" b3="178T186" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="69 KV" b3="18622" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAR" b2="69 KV" b3="186A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAR" b2="13 KV" b3="TX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAR" b2="69 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40180</SeqNum>
    <Name>L69.Pentagon-War.187</Name>
    <LastEdit Timestamp="2026-05-11T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="69 KV" b3="18722" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAR" b2="69 KV" b3="187A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="69 KV" b3="YT187" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAR" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAR" b2="69 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40190</SeqNum>
    <Name>L69.Pentagon-War.188</Name>
    <LastEdit Timestamp="2026-05-11T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="69 KV" b3="18822" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENTAGON" b2="69 KV" b3="188A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="69 KV" b3="ZT188" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAR" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAR" b2="69 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40200</SeqNum>
    <Name>L69.AltaVista-Gladystp-MtAiryDP-Gretna.35</Name>
    <LastEdit Timestamp="2025-12-11T14:35:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALTAVIS2" b2="69 KV" b3="35C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALTAVIS2" b2="69 KV" b3="ALT-MTAI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALTAVIS2" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAVSTA" b2="69 KV" b3="3532" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALTAVSTA" b2="69 KV" b3="ALT-GLAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLADYSDP" b2="69 KV" b3="35A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLADYSDP" b2="69 KV" b3="DP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRETNA" b2="69 KV" b3="35T1040" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRETNA" b2="69 KV" b3="GRE-MTAI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRETNA" b2="69 KV" b3="H222" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRETNA" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRETNA" b2="69 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLADYSTP" b2="69 KV" b3="GLA-KLOP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTAIRYDP" b2="69 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RENAN" b2="69 KV" b3="52-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="RENAN" b2="69 KV" b3="GSU" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTAIRYTP" b2="69 KV" b3="MTA-REN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTAIRYDP" b2="69 KV" b3="MTA-REN2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RENAN" b2="34.5 KV" b3="RENANSP" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLADYSTP" b2="69 KV" b3="GLA-STNM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STNMLSSW" b2="69 KV" b3="SB3572" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40210</SeqNum>
    <Name>L115.ChaseCity-BlackBranch-SpanishGrove.1050</Name>
    <LastEdit Timestamp="2025-08-22T10:25:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLBRANDP" b2="115 KV" b3="BLA-CHAS" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLBRANDP" b2="115 KV" b3="BLA-SPGR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLBRANDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHASECTY" b2="115 KV" b3="105012" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPANGRO" b2="115 KV" b3="10501058" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPANGRO" b2="115 KV" b3="105092" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40220</SeqNum>
    <Name>L765.Cornu-HangingRock + Cornu.U1&amp;2</Name>
    <LastEdit Timestamp="2026-05-11T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CORNU" b2="345 KV" b3="1G1 GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="CORNU" b2="345 KV" b3="1G2 GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CORNU" b2="18 KV" b3="1GT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CORNU" b2="18 KV" b3="1GT2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CORNU" b2="345 KV" b3="2G1 GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="CORNU" b2="345 KV" b3="2G2 GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CORNU" b2="18 KV" b3="2GT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CORNU" b2="18 KV" b3="2GT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORNU" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORNU" b2="765 KV" b3="COR-HAN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CORNU" b2="18 KV" b3="ST1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CORNU" b2="345 KV" b3="ST1 GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CORNU" b2="18 KV" b3="ST2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CORNU" b2="345 KV" b3="ST2 GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="CORNU" b2="765 KV" b3="TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANGING2" b2="765 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40230</SeqNum>
    <Name>L230.GooseCreek-Ashburn-Beaumeade.227</Name>
    <LastEdit Timestamp="2026-04-16T13:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="ASHBURN" b2="230 KV" b3="SC4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ASHBURN" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASHBURN" b2="230 KV" b3="227B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="227T2130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="227T2152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="H292" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAUMEAD" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAUMEAD" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRE" b2="230 KV" b3="227T2286" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASHBURN" b2="230 KV" b3="ASH-GOOS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRE" b2="230 KV" b3="L1T227" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40240</SeqNum>
    <Name>L230.Loudoun-Northstar.2045</Name>
    <LastEdit Timestamp="2024-12-17T12:55:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="20082045" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="204552" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOUDOUN4" b2="230 KV" b3="LOU-NRTH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHSTAR" b2="230 KV" b3="204562-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHSTAR" b2="230 KV" b3="204562-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40250</SeqNum>
    <Name>L230.Loudoun-Racefield.2094</Name>
    <LastEdit Timestamp="2024-06-10T19:10:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="20942140" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="209452" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RACEFIEL" b2="230 KV" b3="209492-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RACEFIEL" b2="230 KV" b3="209492-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOUDOUN4" b2="230 KV" b3="LOU-RACE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40280</SeqNum>
    <Name>L230.Beaumead-Ashburn-PleasantView.274</Name>
    <LastEdit Timestamp="2025-10-30T15:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="ASHBURN" b2="230 KV" b3="SC3" />
      <ContingencyEquipment Action="X" Type="XF" b1="ASHBURN" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ASHBURN" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAUMEAD" b2="230 KV" b3="274C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="274T2130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="274T2206" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="H192" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAUMEAD" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAUMEAD" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="230 KV" b3="203T274" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLEASNTV" b2="230 KV" b3="274D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="230 KV" b3="274T2098" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLEASNTV" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLEASNTV" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40290</SeqNum>
    <Name>L230.Beco-DTC.2249</Name>
    <LastEdit Timestamp="2025-06-16T17:36:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BECO" b2="230 KV" b3="224912" />
      <ContingencyEquipment Action="L" Type="LN" b1="BECO" b2="230 KV" b3="BEC-DTC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECO" b2="230 KV" b3="H3T2249" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DTC" b2="230 KV" b3="224942" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DTC" b2="230 KV" b3="H12T2249" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40320</SeqNum>
    <Name>L138.Oakland-Riazzi.Z42</Name>
    <LastEdit Timestamp="2025-06-20T15:57:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="OAKL DUQ" b2="138 KV" b3="OAK-RIAZ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKL DUQ" b2="138 KV" b3="RIAZZI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIAZZI" b2="138 KV" b3="TIE1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIAZZI" b2="138 KV" b3="TIE2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40330</SeqNum>
    <Name>L138.BeaverValley-Crescent.Z-28</Name>
    <LastEdit Timestamp="2026-05-08T10:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEAV DUQ" b2="138 KV" b3="BEA-CRE8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="138 KV" b3="CRESCEN8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="138 KV" b3="BEAV DUQ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40360</SeqNum>
    <Name>L138.BeaverValley-JLMidland.Z-33</Name>
    <LastEdit Timestamp="2026-05-08T10:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEAV DUQ" b2="138 KV" b3="BEA-JLM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="138 KV" b3="JLMIDLAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JLMIDLAN" b2="138 KV" b3="BEAV CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40370</SeqNum>
    <Name>L138.BeaverValley-Midland.Z-30</Name>
    <LastEdit Timestamp="2026-05-08T10:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAV DUQ" b2="138 KV" b3="2A SS" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAV DUQ" b2="138 KV" b3="BEA-MID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="138 KV" b3="MIDLAND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLAND" b2="138 KV" b3="Z-30" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40380</SeqNum>
    <Name>L138.BeaverValley-Raccoon.Z-37</Name>
    <LastEdit Timestamp="2026-05-08T10:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEAV DUQ" b2="138 KV" b3="BEA-RAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="138 KV" b3="RACCOON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RACC DUQ" b2="138 KV" b3="BEAV DUQ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40390</SeqNum>
    <Name>L138.BeaverValley-Raccoon-Crescent.Z-29</Name>
    <LastEdit Timestamp="2025-08-22T10:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEAV DUQ" b2="138 KV" b3="BEA-RACT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="138 KV" b3="RACT_DUQ" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRES DUQ" b2="138 KV" b3="CRE-RACT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="138 KV" b3="RACT_DUQ" />
      <ContingencyEquipment Action="L" Type="LN" b1="RACC DUQ" b2="138 KV" b3="RAC-RACT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RACC DUQ" b2="138 KV" b3="RACT_DUQ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40400</SeqNum>
    <Name>L138.Bettis-Carson.Z-88</Name>
    <LastEdit Timestamp="2026-05-08T10:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BETTIS" b2="138 KV" b3="BET-CAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETTIS" b2="138 KV" b3="CARSON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARS DUQ" b2="138 KV" b3="Z-88" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40410</SeqNum>
    <Name>L138.Bettis-Dravosburg.Z-107</Name>
    <LastEdit Timestamp="2026-05-08T10:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BETTIS" b2="138 KV" b3="BET-DRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETTIS" b2="138 KV" b3="DRAVOS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="BETTIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40420</SeqNum>
    <Name>L138.Dravosburg-Bocgases-LogansFerry.Z-78</Name>
    <LastEdit Timestamp="2026-05-14T09:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOCGASES" b2="138 KV" b3="BOC-DRA" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOCGASES" b2="138 KV" b3="BOC-LOG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOCGASES" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="BOCGASES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGANSFE" b2="138 KV" b3="BOC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40430</SeqNum>
    <Name>L138.Dravosburg-Brentwood-Elwyn.Z-70</Name>
    <LastEdit Timestamp="2026-05-11T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRENTWOO" b2="138 KV" b3="BRE-DRA" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRENTWOO" b2="138 KV" b3="BRE-ELW" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRENTWOO" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="BRENTWOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELWYN" b2="138 KV" b3="BRENTWOO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40440</SeqNum>
    <Name>L138.Brunot Island-Collier.Z-40</Name>
    <LastEdit Timestamp="2025-01-24T14:29:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNOTIS" b2="138 KV" b3="BRU-COL0" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="COLLIER0" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="138 KV" b3="BRUNOT 0" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40450</SeqNum>
    <Name>L138.Brunot Island-Collier.Z-41</Name>
    <LastEdit Timestamp="2025-01-24T14:29:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNOTIS" b2="138 KV" b3="BRU-COL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="COLLIER1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="138 KV" b3="BRUNOT 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40460</SeqNum>
    <Name>L138.Brunot Island-Montour.Z-44</Name>
    <LastEdit Timestamp="2025-01-24T14:29:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNOTIS" b2="138 KV" b3="BRU-MON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="MONT DUQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONT DUQ" b2="138 KV" b3="BUSTIE21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONT DUQ" b2="138 KV" b3="BUSTIE31" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONT DUQ" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40470</SeqNum>
    <Name>L138.Carson-Homestead-Dravosburg.Z-87</Name>
    <LastEdit Timestamp="2026-05-12T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARS DUQ" b2="138 KV" b3="Z-87" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="CARS DUQ" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARS DUQ" b2="138 KV" b3="CAR-HOM" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOMESTED" b2="138 KV" b3="HOM-DRA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOMESTED" b2="138 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40480</SeqNum>
    <Name>L138.Watson-Forbes.Z-86</Name>
    <LastEdit Timestamp="2025-05-23T14:39:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FORBES" b2="138 KV" b3="TIE 36" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORBES" b2="138 KV" b3="TIE 61" />
      <ContingencyEquipment Action="L" Type="LN" b1="WATSON2" b2="138 KV" b3="WAT-FOR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATSON2" b2="138 KV" b3="TIE2-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATSON2" b2="138 KV" b3="TIE3-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40490</SeqNum>
    <Name>L138.Cheswick-Evergreen-Wilmerding.Z-50</Name>
    <LastEdit Timestamp="2025-10-15T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHESWICK" b2="138 KV" b3="CHE-EVE0" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWICK" b2="138 KV" b3="WILM50" />
      <ContingencyEquipment Action="L" Type="LN" b1="EVERGREE" b2="138 KV" b3="EVE-WIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EVERGREE" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILMERDI" b2="138 KV" b3="Z-50" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40500</SeqNum>
    <Name>L138.Cheswick-LogansFerry.Z-53</Name>
    <LastEdit Timestamp="2024-11-19T16:27:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHESWICK" b2="138 KV" b3="CHE-LF53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWICK" b2="138 KV" b3="Z-53_3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWICK" b2="138 KV" b3="Z-53_4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGANSFE" b2="138 KV" b3="CHESW53" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40510</SeqNum>
    <Name>L138.Cheswick-Pinecreek-North.Z-55</Name>
    <LastEdit Timestamp="2026-05-08T10:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHESWICK" b2="138 KV" b3="CHE-PCT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWICK" b2="138 KV" b3="PINECK55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTH" b2="138 KV" b3="CHES_Z55" />
      <ContingencyEquipment Action="L" Type="LN" b1="PNCRKTAP" b2="138 KV" b3="PCT-NOR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PNCRKTAP" b2="138 KV" b3="PCT-PIN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINECRK" b2="138 KV" b3="PINCKT55" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40520</SeqNum>
    <Name>L138.Cheswick-North.Z-56</Name>
    <LastEdit Timestamp="2024-11-19T16:27:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHESWICK" b2="138 KV" b3="CHE-NOR6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWICK" b2="138 KV" b3="Z-56_3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWICK" b2="138 KV" b3="Z-56_4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTH" b2="138 KV" b3="CHES_Z56" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40530</SeqNum>
    <Name>L138.Cheswick-LogansFerry.Z-52</Name>
    <LastEdit Timestamp="2026-05-12T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHESWICK" b2="138 KV" b3="CHE-LF52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWICK" b2="138 KV" b3="LOGNFE52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGANSFE" b2="138 KV" b3="CHESW52" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40540</SeqNum>
    <Name>Cheswick.138.Cap2</Name>
    <LastEdit Timestamp="2026-05-12T09:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWICK" b2="138 KV" b3="CAP2 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CHESWICK" b2="138 KV" b3="CAP2A" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CHESWICK" b2="138 KV" b3="CAP2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40550</SeqNum>
    <Name>L138.Clinton-Findlay.Z-34</Name>
    <LastEdit Timestamp="2026-05-08T10:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLIN DUQ" b2="138 KV" b3="CLI-FIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIN DUQ" b2="138 KV" b3="FINDLAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINDLAY" b2="138 KV" b3="CLINTON" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40560</SeqNum>
    <Name>L138.Collier-Elwyn.Z-62</Name>
    <LastEdit Timestamp="2026-05-08T10:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLLIER" b2="138 KV" b3="COL-ELW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="138 KV" b3="Z-62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELWYN" b2="138 KV" b3="Z-62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40570</SeqNum>
    <Name>L138.Collier-WoodvilleDUQ.Z-63</Name>
    <LastEdit Timestamp="2025-10-15T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLLIER" b2="138 KV" b3="COL-WOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="138 KV" b3="WOODVIL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVILL" b2="138 KV" b3="COLLIER" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40580</SeqNum>
    <Name>L138.Collier-WoodvilleDUQ.Z-64</Name>
    <LastEdit Timestamp="2025-10-15T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLLIER" b2="138 KV" b3="COL-WOO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="138 KV" b3="WOODVIL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVILL" b2="138 KV" b3="COLLIER2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40600</SeqNum>
    <Name>L138.Crescent-MtNebo-North.Z-20</Name>
    <LastEdit Timestamp="2026-05-14T09:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRES DUQ" b2="138 KV" b3="CRE-MTN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="138 KV" b3="MTNEBO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MT NEBO" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MT NEBO" b2="138 KV" b3="MTN-NOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTH" b2="138 KV" b3="MTNEBO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40610</SeqNum>
    <Name>L138.Crescent-North.Z-21</Name>
    <LastEdit Timestamp="2026-05-11T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRES DUQ" b2="138 KV" b3="CRE-NOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="138 KV" b3="NORTH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTH" b2="138 KV" b3="CRESCENT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40620</SeqNum>
    <Name>L138.Dravosburg-Carson.Z-71</Name>
    <LastEdit Timestamp="2026-05-11T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARS DUQ" b2="138 KV" b3="CAR-DRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARS DUQ" b2="138 KV" b3="Z-71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="Z-71" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40630</SeqNum>
    <Name>L138.Dravosburg-USS Illinois.Z-79</Name>
    <LastEdit Timestamp="2026-05-11T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DRAVOSBU" b2="138 KV" b3="DRA-USS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DRAVOSBU" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="USSILLIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="USSILLIN" b2="138 KV" b3="DRAVOS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40640</SeqNum>
    <Name>L138.Dravosburg-WestMifflin.Z-73</Name>
    <LastEdit Timestamp="2026-05-11T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DRAVOSBU" b2="138 KV" b3="DRA-WMI3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="WMIFFLI3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMIFFLIN" b2="138 KV" b3="DRAVOS3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40650</SeqNum>
    <Name>L138.Dravosburg-WestMifflin.Z-74</Name>
    <LastEdit Timestamp="2026-05-11T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DRAVOSBU" b2="138 KV" b3="DRA-WMI4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="WMIFFLI4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMIFFLIN" b2="138 KV" b3="DRAVOS4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40660</SeqNum>
    <Name>L138.Findlay-Sewickley.T-43/45</Name>
    <LastEdit Timestamp="2026-05-26T09:51:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONT DUQ" b2="138 KV" b3="BUSTIE31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONT DUQ" b2="138 KV" b3="BUSTIE32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWICKLY" b2="138 KV" b3="BIZ-43" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONT DUQ" b2="138 KV" b3="MON-SEW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40670</SeqNum>
    <Name>L138.Hopewell-Legionville.Z-90</Name>
    <LastEdit Timestamp="2026-05-11T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HOPEWELL" b2="138 KV" b3="HOP-LEG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWELL" b2="138 KV" b3="LEGI90CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGIONVI" b2="138 KV" b3="HOPE90CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40680</SeqNum>
    <Name>L138.Midland-JLMidland.Z-36</Name>
    <LastEdit Timestamp="2026-05-11T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JLMIDLAN" b2="138 KV" b3="JLM-MID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JLMIDLAN" b2="138 KV" b3="MIDLAN36" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLAND" b2="138 KV" b3="Z-36" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40690</SeqNum>
    <Name>L138.Crescent-Legionville.Z-26</Name>
    <LastEdit Timestamp="2026-05-11T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRES DUQ" b2="138 KV" b3="CRE-LEG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="138 KV" b3="Z-26 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGIONVI" b2="138 KV" b3="CRES26CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40780</SeqNum>
    <Name>L69.Cultrham-Valley</Name>
    <LastEdit Timestamp="2025-02-18T16:02:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CUTLRHAM" b2="69 KV" b3="CUT-HOPE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CUTLRHAM" b2="69 KV" b3="CUT-VAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CUTLRHAM" b2="69 KV" b3="CUTLER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWELL" b2="69 KV" b3="66141" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="69 KV" b3="66141" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40790</SeqNum>
    <Name>138/69.Brunot Island.TR1</Name>
    <LastEdit Timestamp="2026-01-07T10:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="BUSTIE15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="BUSTIE16" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNOTIS" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="69 KV" b3="TR1 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40800</SeqNum>
    <Name>138/69.Brunot Island.TR2</Name>
    <LastEdit Timestamp="2026-01-08T09:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNOTIS" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="TR2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="69 KV" b3="TR2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40810</SeqNum>
    <Name>DTX138.North.T1</Name>
    <LastEdit Timestamp="2024-10-24T14:20:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NORTH" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTH" b2="138 KV" b3="TIE3-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTH" b2="138 KV" b3="TIE4-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40830</SeqNum>
    <Name>138/23.Valley.TR2</Name>
    <LastEdit Timestamp="2024-12-12T13:32:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="138 KV" b3="2-3" />
      <ContingencyEquipment Action="X" Type="XF" b1="VALL DUQ" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="23 KV" b3="TR2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="138 KV" b3="Z-183" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40850</SeqNum>
    <Name>138/69.Dravosburg.T2</Name>
    <LastEdit Timestamp="2026-05-11T12:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="BOCGASES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="CAPAB CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="PERRYCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="RANKIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DRAVOSBU" b2="138 KV" b3="RANKINLD" />
      <ContingencyEquipment Action="X" Type="XF" b1="DRAVOSBU" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="69 KV" b3="T2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="TIE2-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40860</SeqNum>
    <Name>L230.Cartanza-Milford.23033</Name>
    <LastEdit Timestamp="2026-05-11T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTANZA" b2="230 KV" b3="235" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTANZA" b2="230 KV" b3="236" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARTANZA" b2="230 KV" b3="CAR-MIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="230 KV" b3="9320" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40870</SeqNum>
    <Name>L230.CedarCreek-Milford.23031</Name>
    <LastEdit Timestamp="2026-05-11T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCRE" b2="230 KV" b3="230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCRE" b2="230 KV" b3="233" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARCRE" b2="230 KV" b3="CED-MIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="230 KV" b3="9380" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40880</SeqNum>
    <Name>L345.Burnham-Calumet-Taylor.17724</Name>
    <LastEdit Timestamp="2025-06-03T13:09:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="150 CALU" b2="345 KV" b3="17724 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="150 CALU" b2="345 KV" b3="17724 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="150 CALU" b2="345 KV" b3="17724I3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="150 CALU" b2="345 KV" b3="17724I4" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="150 CALU" b2="345 KV" b3="17724RE3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="150 CALU" b2="345 KV" b3="17724RE4" />
      <ContingencyEquipment Action="S" Type="SD" b1="150 CALU" b2="345 KV" b3="SD24BY" />
      <ContingencyEquipment Action="L" Type="LN" b1="153 TAYL" b2="345 KV" b3="17724 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="153 TAYL" b2="345 KV" b3="17724 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="345 KV" b3="BT1112CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40890</SeqNum>
    <Name>L345.Hiple-Leesburg (NIPSCO)</Name>
    <LastEdit Timestamp="2024-11-18T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34524" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34524-00" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIPLE" b2="345 KV" b3="HIP-LEE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESBURG" b2="345 KV" b3="1824" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESBURG" b2="345 KV" b3="924" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40900</SeqNum>
    <Name>L138.EastDanville-Banister-Bearskin-Museville</Name>
    <LastEdit Timestamp="2025-08-14T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BANISTE4" b2="35 KV" b3="BUS2LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="BANISTE4" b2="138 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BANISTE4" b2="138 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BANISTER" b2="138 KV" b3="BAN-BAN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BANISTER" b2="138 KV" b3="BAN-BEA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDANVILL" b2="138 KV" b3="EDA-BAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARSKI4" b2="138 KV" b3="H102" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEARSKIN" b2="138 KV" b3="BEA-BEA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEARSKIN" b2="138 KV" b3="BEA-MUSE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDANVILL" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSEVILL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSEVILL" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40930</SeqNum>
    <Name>L138.Corbin-SouthOttawa (IP/MISO)</Name>
    <LastEdit Timestamp="2025-03-10T14:48:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRBN" b2="138 KV" b3="CRB-SOTT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRBN" b2="138 KV" b3="H51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRBN" b2="138 KV" b3="H53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOTTAWA" b2="138 KV" b3="H11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOTTAWA" b2="138 KV" b3="H9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40950</SeqNum>
    <Name>L138.Dune Acres-Michigan City.43</Name>
    <LastEdit Timestamp="2025-03-24T09:55:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNEACRE" b2="138 KV" b3="43" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUNEACRE" b2="138 KV" b3="DUN-MIC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICHIGA2" b2="138 KV" b3="43" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MICHIGA2" b2="138 KV" b3="43_TB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>40960</SeqNum>
    <Name>L138.Dune Acres-Michigan City.39</Name>
    <LastEdit Timestamp="2025-03-24T09:55:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNEACRE" b2="138 KV" b3="39" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUNEACRE" b2="138 KV" b3="DUN-MIC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICHIGA2" b2="138 KV" b3="39" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MICHIGA2" b2="138 KV" b3="39_TB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41030</SeqNum>
    <Name>L345.Babcock-DuneAcres (NIPS)</Name>
    <LastEdit Timestamp="2026-05-14T09:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABCOCK" b2="345 KV" b3="203" />
      <ContingencyEquipment Action="L" Type="LN" b1="BABCOCK" b2="345 KV" b3="BAB-DUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABCOCK" b2="345 KV" b3="BUST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNEACRE" b2="345 KV" b3="206" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNEACRE" b2="345 KV" b3="210" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41040</SeqNum>
    <Name>L345.Babcock-LakeGeorge (NIPS)</Name>
    <LastEdit Timestamp="2026-05-14T09:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABCOCK" b2="345 KV" b3="203" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABCOCK" b2="345 KV" b3="305" />
      <ContingencyEquipment Action="L" Type="LN" b1="BABCOCK" b2="345 KV" b3="BAB-LAK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="345 KV" b3="300" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41050</SeqNum>
    <Name>L345.Babcock-MichiganCity (NIPS)</Name>
    <LastEdit Timestamp="2026-05-14T09:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABCOCK" b2="345 KV" b3="305" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABCOCK" b2="345 KV" b3="523" />
      <ContingencyEquipment Action="L" Type="LN" b1="BABCOCK" b2="345 KV" b3="BAB-MIC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICHIGA2" b2="345 KV" b3="05" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICHIGA2" b2="345 KV" b3="0506" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41060</SeqNum>
    <Name>345/138.Stillwell.T1 (NIPS)</Name>
    <LastEdit Timestamp="2025-04-22T11:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="STILLWEL" b2="345 KV" b3=".  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STILLWEL" b2="345 KV" b3="X1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STILLWEL" b2="138 KV" b3="X197" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STILLWEL" b2="138 KV" b3="X1X" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41070</SeqNum>
    <Name>L345.Babcock-TowerRoad + 345/138.TowerRoad (NIPS)</Name>
    <LastEdit Timestamp="2025-10-14T18:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABCOCK" b2="345 KV" b3="1423" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABCOCK" b2="345 KV" b3="523" />
      <ContingencyEquipment Action="L" Type="LN" b1="BABCOCK" b2="345 KV" b3="BAB-TOW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWERRD" b2="345 KV" b3="723" />
      <ContingencyEquipment Action="X" Type="XF" b1="TOWERRD" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWERRD" b2="138 KV" b3="X272" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWERRD" b2="138 KV" b3="X298" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41080</SeqNum>
    <Name>L345.BurrOak-Leesburg (NIPS)</Name>
    <LastEdit Timestamp="2025-08-22T08:18:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURR_OAK" b2="345 KV" b3="09-40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURR_OAK" b2="345 KV" b3="9" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURR_OAK" b2="345 KV" b3="BUR-LEE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESBURG" b2="345 KV" b3="9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESBURG" b2="345 KV" b3="924" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41100</SeqNum>
    <Name>345/138.GaryAve.T-A (NIPS)</Name>
    <LastEdit Timestamp="2026-05-12T09:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GARYAVE" b2="138 KV" b3="138104BR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARYAVE" b2="345 KV" b3="34510_BR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARYAVE" b2="345 KV" b3="34520_BR" />
      <ContingencyEquipment Action="X" Type="XF" b1="GARYAVE" b2="345 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41110</SeqNum>
    <Name>L345.Deedsville-Walton</Name>
    <LastEdit Timestamp="2026-02-19T05:55:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEEDSVIL" b2="345 KV" b3="47-18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEEDSVIL" b2="345 KV" b3="B1-47" />
      <ContingencyEquipment Action="L" Type="LN" b1="WALTON_3" b2="345 KV" b3="WAL-DEE1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WALTON_3" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALTON_3" b2="230 KV" b3="21B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALTON_3" b2="230 KV" b3="B223" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41120</SeqNum>
    <Name>L345.DuneAcres-MichganCity (NIPS)</Name>
    <LastEdit Timestamp="2025-05-20T11:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNEACRE" b2="345 KV" b3="206" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNEACRE" b2="345 KV" b3="6" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUNEACRE" b2="345 KV" b3="DUN-MIC3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICHIGA2" b2="345 KV" b3="0506" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICHIGA2" b2="345 KV" b3="06" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41130</SeqNum>
    <Name>L345.Green Acres-Schahfer (NIPS)</Name>
    <LastEdit Timestamp="2026-05-15T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENACR" b2="345 KV" b3="1516" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENACR" b2="345 KV" b3="16" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENACR" b2="345 KV" b3="GRE-SCH1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="816" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41140</SeqNum>
    <Name>L345.GreenAcres-StJohns.6617 (NIPS)</Name>
    <LastEdit Timestamp="2025-10-07T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENACR" b2="345 KV" b3="1517" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENACR" b2="345 KV" b3="17" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENACR" b2="345 KV" b3="GRE-STJO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS" b2="345 KV" b3="1719" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS" b2="345 KV" b3="1721" />
      <ContingencyEquipment Action="L" Type="LN" b1="STJOGRAC" b2="345 KV" b3="STJ-STJO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41150</SeqNum>
    <Name>L345.LakeGeorge-Munster (NIPS)</Name>
    <LastEdit Timestamp="2025-04-28T15:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="345 KV" b3="22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="345 KV" b3="822" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEGEOR" b2="345 KV" b3="LAK-MUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUNSTER2" b2="345 KV" b3="0422_BKR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUNSTER2" b2="345 KV" b3="22_BKR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41160</SeqNum>
    <Name>L345.LakeGeorge-Schahfer (NIPS)</Name>
    <LastEdit Timestamp="2026-05-11T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="345 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="345 KV" b3="822" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEGEOR" b2="345 KV" b3="LAK-SCH1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="816" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41170</SeqNum>
    <Name>L345.Schahfer-StJohns (NIPS)</Name>
    <LastEdit Timestamp="2025-08-11T15:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="21U17" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCHAHFER" b2="345 KV" b3="SCH-STJ1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS" b2="345 KV" b3="1721" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS" b2="345 KV" b3="21" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41180</SeqNum>
    <Name>L345.Schahfer-TowerRoad (NIPS)</Name>
    <LastEdit Timestamp="2025-09-16T10:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="7U15" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCHAHFER" b2="345 KV" b3="SCH-TOW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWERRD" b2="345 KV" b3="723" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41190</SeqNum>
    <Name>345/138.BurrOak.A</Name>
    <LastEdit Timestamp="2026-05-12T09:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURR_OAK" b2="138 KV" b3="19-XFR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURR_OAK" b2="138 KV" b3="82-XFR2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURR_OAK" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURR_OAK" b2="345 KV" b3="X2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41200</SeqNum>
    <Name>345/138.DuneAcres.A (NIPS)</Name>
    <LastEdit Timestamp="2024-06-12T15:23:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DUNEACRE" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNEACRE" b2="345 KV" b3="X3CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNEACRE" b2="138 KV" b3="X3N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNEACRE" b2="138 KV" b3="X3S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41210</SeqNum>
    <Name>345/138.LakeGeorge.A1 (NIPS)</Name>
    <LastEdit Timestamp="2026-05-12T09:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="345 KV" b3="22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="345 KV" b3="300" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKEGEOR" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="138 KV" b3="X100" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="138 KV" b3="X11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41220</SeqNum>
    <Name>345/138.LakeGeorge.B2 (NIPS)</Name>
    <LastEdit Timestamp="2026-05-12T09:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="345 KV" b3="8" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKEGEOR" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="138 KV" b3="X222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="138 KV" b3="X2X" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41230</SeqNum>
    <Name>345/138.Leesburg.A (NIPS)</Name>
    <LastEdit Timestamp="2025-04-03T09:44:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESBURG" b2="345 KV" b3="18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESBURG" b2="345 KV" b3="9" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEESBURG" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESBURG" b2="138 KV" b3="X221" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESBURG" b2="138 KV" b3="X281" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41240</SeqNum>
    <Name>345/138.Schahfer.A (NIPS)</Name>
    <LastEdit Timestamp="2026-05-12T09:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="138 KV" b3="51 XFR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="8" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCHAHFER" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="U180" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="138 KV" b3="XF7 XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41250</SeqNum>
    <Name>345/138.Sheffield.T2 (NIPS)</Name>
    <LastEdit Timestamp="2026-05-14T09:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="345 KV" b3="12" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHEFFILD" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="345 KV" b3="2000" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="138 KV" b3="X204" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="138 KV" b3="X293" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41260</SeqNum>
    <Name>345/138.StJohns.T2 (NIPS)</Name>
    <LastEdit Timestamp="2025-04-29T17:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS" b2="345 KV" b3="19" />
      <ContingencyEquipment Action="X" Type="XF" b1="STJOHNS" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS" b2="345 KV" b3="21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS" b2="138 KV" b3="X268" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS" b2="138 KV" b3="X2CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41270</SeqNum>
    <Name>Schahfer.U14 (NIPS)</Name>
    <LastEdit Timestamp="2025-08-11T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="13U14" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SCHAHFER" b2="345 KV" b3="SH14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="U14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41280</SeqNum>
    <Name>Schahfer.U15 (NIPS)</Name>
    <LastEdit Timestamp="2026-05-15T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="7U15" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SCHAHFER" b2="345 KV" b3="SH15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="U15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41290</SeqNum>
    <Name>Schahfer.U17 (NIPS)</Name>
    <LastEdit Timestamp="2025-08-11T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="21U17" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SCHAHFER" b2="345 KV" b3="SH17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="U17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41300</SeqNum>
    <Name>Schahfer.U18 (NIPS)</Name>
    <LastEdit Timestamp="2026-05-15T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="SCHAHFER" b2="345 KV" b3="SH18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="U18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="U180" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41310</SeqNum>
    <Name>Michigan City.U12 (NIPS)</Name>
    <LastEdit Timestamp="2026-05-19T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MICHIGA2" b2="345 KV" b3="05" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICHIGA2" b2="345 KV" b3="06" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MICHIGA2" b2="345 KV" b3="MC12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41320</SeqNum>
    <Name>L345.MapleRidge-Tazewell</Name>
    <LastEdit Timestamp="2026-03-26T10:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLERID" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLERID" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAPLERID" b2="345 KV" b3="MAP-TAZ2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWEL2" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWEL2" b2="345 KV" b3="V15" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TAZEWEL2" b2="345 KV" b3="V23B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41330</SeqNum>
    <Name>L138.Tower Rd - Flint Lake</Name>
    <LastEdit Timestamp="2026-05-15T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="17FLNTLK" b2="138 KV" b3="72" />
      <ContingencyEquipment Action="L" Type="LN" b1="TOWERRD" b2="138 KV" b3="TOW-17F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWERRD" b2="138 KV" b3="6672" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWERRD" b2="138 KV" b3="X272" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41360</SeqNum>
    <Name>L138.Flint Lake-Luchtman Road</Name>
    <LastEdit Timestamp="2026-05-14T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="17FLNTLK" b2="138 KV" b3="17F-LUC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17FLNTLK" b2="138 KV" b3="73" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUCHTAP" b2="138 KV" b3="38TI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41370</SeqNum>
    <Name>L138.LuchtmanRoad-Shoreline</Name>
    <LastEdit Timestamp="2026-05-08T11:36:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LUCHTAP" b2="138 KV" b3="1XFR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUCHTAP" b2="138 KV" b3="3815" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUCHTAP" b2="138 KV" b3="38TI" />
      <ContingencyEquipment Action="L" Type="LN" b1="LUCHTAP" b2="138 KV" b3="LUC-SHOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHORELIN" b2="138 KV" b3="15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHORELIN" b2="138 KV" b3="15-121" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41380</SeqNum>
    <Name>L138.Maple-LNGPLNTP (NIPS)</Name>
    <LastEdit Timestamp="2026-05-14T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LNGPLNTP" b2="138 KV" b3="3812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLNIPS" b2="138 KV" b3="12" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAPLNIPS" b2="138 KV" b3="MAP-LNG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41390</SeqNum>
    <Name>L138.Stillwell-LNGPLNTP (NIPS)</Name>
    <LastEdit Timestamp="2026-05-14T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LNGPLNTP" b2="138 KV" b3="3897" />
      <ContingencyEquipment Action="L" Type="LN" b1="STILLWEL" b2="138 KV" b3="STI-LNG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STILLWEL" b2="138 KV" b3="9697" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STILLWEL" b2="138 KV" b3="X197" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41410</SeqNum>
    <Name>L230.Bradford-Jennersville-Clay.220-96</Name>
    <LastEdit Timestamp="2025-04-08T14:16:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="230 KV" b3="230" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADFORD" b2="230 KV" b3="BRA-JEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAY PE" b2="230 KV" b3="785" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAY PE" b2="230 KV" b3="825" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAY PE" b2="230 KV" b3="CLA-JEN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JENNERVL" b2="230 KV" b3="1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41420</SeqNum>
    <Name>L230.Conowingo-Colora.220-88</Name>
    <LastEdit Timestamp="2026-05-15T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLORA" b2="230 KV" b3="235" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLORA" b2="230 KV" b3="745 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="230 KV" b3="220-88CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLORA" b2="230 KV" b3="COL-CON2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41430</SeqNum>
    <Name>230/13.Conowingo.GSU.TR1-4 + Conowingo.U1-U7</Name>
    <LastEdit Timestamp="2025-12-01T13:32:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="1 GEN CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="2 GEN CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="230 KV" b3="220-88CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONOWING" b2="13 KV" b3="2WLOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="3 GEN CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="4 GEN CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="5 GEN CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="6 GEN CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="13 KV" b3="7 GEN CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONOWING" b2="230 KV" b3="BUSTIE D" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONOWING" b2="230 KV" b3="CONO1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONOWING" b2="230 KV" b3="CONO2TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONOWING" b2="230 KV" b3="CONO3TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONOWING" b2="230 KV" b3="CONO4TR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="GEN6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONOWING" b2="13 KV" b3="UNIT07" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41460</SeqNum>
    <Name>Brunot Island.U4</Name>
    <LastEdit Timestamp="2026-05-14T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="GEN4 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNOTIS" b2="138 KV" b3="GSU4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRUNOTIS" b2="13 KV" b3="UNIT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41470</SeqNum>
    <Name>Brunot Island.U3</Name>
    <LastEdit Timestamp="2026-05-14T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="GEN3 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNOTIS" b2="138 KV" b3="GSU3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRUNOTIS" b2="13 KV" b3="UNIT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41480</SeqNum>
    <Name>Brunot Island.CT1</Name>
    <LastEdit Timestamp="2026-05-14T16:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="BRUNOTIS" b2="13 KV" b3="CT1A" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNOTIS" b2="138 KV" b3="GSU1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNOTIS" b2="138 KV" b3="ORANGELD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="TIE2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="TIE3-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41490</SeqNum>
    <Name>Brunot Island.CT2</Name>
    <LastEdit Timestamp="2026-05-14T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="BRUNOTIS" b2="13 KV" b3="CT2A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRUNOTIS" b2="13 KV" b3="CT2B" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNOTIS" b2="69 KV" b3="GSU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="69 KV" b3="GSU2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41530</SeqNum>
    <Name>500/230.Branchburg.500-3</Name>
    <LastEdit Timestamp="2025-05-30T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="500 KV" b3="500-3HCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRANCHBU" b2="500 KV" b3="500-3T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT 2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT 3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41550</SeqNum>
    <Name>L345.Wempletown-Paddock.17102.Tie (ATC)</Name>
    <LastEdit Timestamp="2025-01-09T14:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="171 WEMP" b2="345 KV" b3="17102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="171 WEMP" b2="345 KV" b3="BT2-11CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="171 WEMP" b2="345 KV" b3="BT2-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADDOCK" b2="345 KV" b3="2206-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADDOCK" b2="345 KV" b3="2222-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41560</SeqNum>
    <Name>L345.Spurlock-Stuart</Name>
    <LastEdit Timestamp="2024-10-22T17:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB1474" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB153T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUART2" b2="345 KV" b3="GG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUART2" b2="345 KV" b3="HH" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPURLOCK" b2="345 KV" b3="SPU-STU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41570</SeqNum>
    <Name>L345.MeldahlDamTap-Zimmer</Name>
    <LastEdit Timestamp="2026-05-15T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MELDALTP" b2="345 KV" b3="1537" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELDALTP" b2="345 KV" b3="1539" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZIMMER2" b2="345 KV" b3="1445" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZIMMER2" b2="345 KV" b3="1449" />
      <ContingencyEquipment Action="L" Type="LN" b1="MELDALTP" b2="345 KV" b3="MEL-ZIM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41580</SeqNum>
    <Name>L138.GoshenJct-Northeast(NIPSCo)</Name>
    <LastEdit Timestamp="2026-05-14T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="17GSHJCT" b2="138 KV" b3="X180" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17GSHJCT" b2="138 KV" b3="X280" />
      <ContingencyEquipment Action="L" Type="LN" b1="17GSHJCT" b2="138 KV" b3="17G-NOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEA2" b2="138 KV" b3="80" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41590</SeqNum>
    <Name>FourRivers.U6</Name>
    <LastEdit Timestamp="2026-05-14T16:43:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="230 KV" b3="20322067" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="230 KV" b3="20442067" />
      <ContingencyEquipment Action="S" Type="SD" b1="FOURRIVR" b2="230 KV" b3="20672" />
      <ContingencyEquipment Action="X" Type="XF" b1="FOURRIVR" b2="230 KV" b3="GSUGT601" />
      <ContingencyEquipment Action="X" Type="XF" b1="FOURRIVR" b2="230 KV" b3="GSUGT602" />
      <ContingencyEquipment Action="X" Type="XF" b1="FOURRIVR" b2="230 KV" b3="GSUST601" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOURRIVR" b2="13.8 KV" b3="GT601" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOURRIVR" b2="13.8 KV" b3="GT602" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOURRIVR" b2="13.8 KV" b3="ST601" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41600</SeqNum>
    <Name>L345.138 Slverlke-141 Pleasant Vlly &amp; P.V. TR81</Name>
    <LastEdit Timestamp="2026-05-15T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="138 SILV" b2="345 KV" b3="13817" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="141 PLEA" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="141 PLEA" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="141 PLEA" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41640</SeqNum>
    <Name>RAS.L230.Clover-Easters.2226+ Clover.U2</Name>
    <LastEdit Timestamp="2026-02-11T06:36:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="222612" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="25 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G2TL9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOVER" b2="7 KV" b3="SS2LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="SX122226" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="222632" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVER" b2="230 KV" b3="CLV-EAST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="WT2226" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41750</SeqNum>
    <Name>L230.Cardiff-Cedar</Name>
    <LastEdit Timestamp="2026-05-15T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARDIFF" b2="230 KV" b3="CAR-CED" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="DT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="U CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="230 KV" b3="GCB QQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="230 KV" b3="GCB SS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41770</SeqNum>
    <Name>L69.Laurel-Roadstown.0799</Name>
    <LastEdit Timestamp="2024-10-02T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAUREL" b2="69 KV" b3="LAU-ROA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUREL" b2="69 KV" b3="OCB B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROADSTOW" b2="69 KV" b3="A CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41970</SeqNum>
    <Name>L115.Granite-Hollofield-Chestnut.110529</Name>
    <LastEdit Timestamp="2026-04-07T08:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTNUT" b2="115 KV" b3="110527CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTNUT" b2="115 KV" b3="527-537" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTNUT" b2="115 KV" b3="CHE-HOL7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="115 KV" b3="110529" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="115 KV" b3="561A_529" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANITE" b2="115 KV" b3="GRA-HOL7" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HOLLOFIE" b2="115 KV" b3="1-2 BUS" />
      <ContingencyEquipment Action="S" Type="SD" b1="HOLLOFIE" b2="115 KV" b3="110527-B" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HOLLOFIE" b2="115 KV" b3="110529" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MEADOWBC" b2="115 KV" b3="2TR536" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MEADOWBC" b2="115 KV" b3="2TR537" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41980</SeqNum>
    <Name>345/138.Bixby.T1</Name>
    <LastEdit Timestamp="2025-10-07T10:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BIXBY" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="138 KV" b3="107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="345 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="345 KV" b3="F2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>41990</SeqNum>
    <Name>345/138.Corridor.T2</Name>
    <LastEdit Timestamp="2025-05-28T12:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="106C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="106N" />
      <ContingencyEquipment Action="X" Type="XF" b1="CORRIDOR" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="345 KV" b3="304C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="345 KV" b3="304N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42000</SeqNum>
    <Name>345/138.Corridor.T1</Name>
    <LastEdit Timestamp="2024-10-30T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CORRIDOR" b2="345 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="CORRIDOR" b2="138 KV" b3="1-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="102C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="102N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="345 KV" b3="302C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="345 KV" b3="302S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42020</SeqNum>
    <Name>L345.Zimmer-PortUnion.4544</Name>
    <LastEdit Timestamp="2026-05-15T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="345 KV" b3="1371" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="345 KV" b3="1373" />
      <ContingencyEquipment Action="L" Type="LN" b1="PORTUNIO" b2="345 KV" b3="POR-ZIM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZIMMER2" b2="345 KV" b3="1443" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZIMMER2" b2="345 KV" b3="1445" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42030</SeqNum>
    <Name>L69.Mill-Searstown.0775-1</Name>
    <LastEdit Timestamp="2026-05-15T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MILL" b2="69 KV" b3="MIL-SEA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MILL" b2="69 KV" b3="OCB U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEARSTOW" b2="69 KV" b3="CB A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42040</SeqNum>
    <Name>L69.Ontario-Searstown.0602</Name>
    <LastEdit Timestamp="2025-09-08T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ONTARIO" b2="69 KV" b3="OCB F" />
      <ContingencyEquipment Action="L" Type="LN" b1="ONTARIO" b2="69 KV" b3="ONT-SEAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEARSTOW" b2="69 KV" b3="CB B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42110</SeqNum>
    <Name>L69.Atco-Berlin-SilverLake.0706</Name>
    <LastEdit Timestamp="2025-09-09T11:37:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATCO" b2="69 KV" b3="OCB B" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATCO" b2="69 KV" b3="ATC-BER" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERLIN" b2="69 KV" b3="BER-SIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERLIN" b2="69 KV" b3="IBUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERLA" b2="69 KV" b3="OCB E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42120</SeqNum>
    <Name>L69.ATCO-Berlin.0706-2</Name>
    <LastEdit Timestamp="2026-05-15T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ATCO" b2="69 KV" b3="ATC-BER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATCO" b2="69 KV" b3="OCB B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERLIN" b2="69 KV" b3="ABS A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42140</SeqNum>
    <Name>L69.Pitman-Rowan.0793</Name>
    <LastEdit Timestamp="2025-11-30T18:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PITMAN" b2="69 KV" b3="OCB N" />
      <ContingencyEquipment Action="L" Type="LN" b1="PITMAN" b2="69 KV" b3="PIT-ROW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROWAN" b2="69 KV" b3="GCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROWAN" b2="69 KV" b3="GCB B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42160</SeqNum>
    <Name>L69.Lamb-Pitman</Name>
    <LastEdit Timestamp="2026-05-15T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMB" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAMB" b2="69 KV" b3="LAM-PIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PITMAN" b2="69 KV" b3="OCB B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42170</SeqNum>
    <Name>L69.Sickler-PineHill-Stratford.0728</Name>
    <LastEdit Timestamp="2025-12-01T13:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEHILL" b2="69 KV" b3="OCB B" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINEHILL" b2="69 KV" b3="PIN-PIN" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINEHTAP" b2="69 KV" b3="PIN-SIC" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINEHTAP" b2="69 KV" b3="PIN-STR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SICKLER" b2="69 KV" b3="OCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRATFOR" b2="69 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42180</SeqNum>
    <Name>L69.Lindenwold-Stratford.0615</Name>
    <LastEdit Timestamp="2025-12-01T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDENWO" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINDENWO" b2="69 KV" b3="LIN-STR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRATFOR" b2="69 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42190</SeqNum>
    <Name>L69.PineHill-Terrace.0756-1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-21T13:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEHILL" b2="69 KV" b3="OCB A" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINEHILL" b2="69 KV" b3="PIN-TER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERRACE" b2="69 KV" b3="ABS G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42210</SeqNum>
    <Name>L345.Ghent-WestLexington + 345/138.WLxngtn.T156</Name>
    <LastEdit Timestamp="2025-08-26T18:08:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_912" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_914" />
      <ContingencyEquipment Action="L" Type="LN" b1="GHENT_LG" b2="345 KV" b3="WLE-GHEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_LXNGT" b2="345 KV" b3="904" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_LXNGT" b2="138 KV" b3="B154_708" />
      <ContingencyEquipment Action="X" Type="XF" b1="W_LXNGT" b2="345 KV" b3="XF156" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42220</SeqNum>
    <Name>L345.Ghent-WestFrankfort</Name>
    <LastEdit Timestamp="2025-06-03T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_922" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_924" />
      <ContingencyEquipment Action="L" Type="LN" b1="GHENT_LG" b2="345 KV" b3="WFR-GHEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_FNKFT" b2="138 KV" b3="B211_708" />
      <ContingencyEquipment Action="X" Type="XF" b1="W_FNKFT" b2="345 KV" b3="XF154" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42230</SeqNum>
    <Name>L138.PaxtonEast-Gilman-Rice</Name>
    <LastEdit Timestamp="2026-03-09T12:07:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GILMAN 3" b2="138 KV" b3="GIL-PAXT" />
      <ContingencyEquipment Action="L" Type="LN" b1="GILMAN 3" b2="138 KV" b3="GIL-RICE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GILMAN 3" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAXT1600" b2="138 KV" b3="1831" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICE" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICE" b2="138 KV" b3="H5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42260</SeqNum>
    <Name>138/69.Tuna.TR4</Name>
    <LastEdit Timestamp="2026-05-14T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="138 KV" b3="045" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="69 KV" b3="120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="69 KV" b3="130" />
      <ContingencyEquipment Action="X" Type="XF" b1="TUNA" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42280</SeqNum>
    <Name>L138.Tuna-Callowhill &amp; 138/13.Callowhill.2&amp;5&amp;8</Name>
    <LastEdit Timestamp="2025-08-06T13:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CALLOWHI" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALLOWHI" b2="13 KV" b3="5TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALLOWHI" b2="13 KV" b3="8TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CALLOWHI" b2="138 KV" b3="CAL 2TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CALLOWHI" b2="138 KV" b3="CAL 5TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CALLOWHI" b2="138 KV" b3="CAL 8TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CALLOWHI" b2="138 KV" b3="CAL-TUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="138 KV" b3="085" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42290</SeqNum>
    <Name>L138.Tuna-Waneeta</Name>
    <LastEdit Timestamp="2025-07-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="138 KV" b3="025" />
      <ContingencyEquipment Action="L" Type="LN" b1="TUNA" b2="138 KV" b3="TUN-WAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="138 KV" b3="25 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42310</SeqNum>
    <Name>L230.Cayuga-Veedersburg</Name>
    <LastEdit Timestamp="2026-01-12T12:00:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="230 KV" b3="1103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="230 KV" b3="13-11" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAYUGA2" b2="230 KV" b3="CAY-VEE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VEEDERSB" b2="230 KV" b3="11-B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VEEDERSB" b2="230 KV" b3="B2-11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42330</SeqNum>
    <Name>L230.Lafayette-Attica-Veedersburg</Name>
    <LastEdit Timestamp="2026-01-16T13:08:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="08LAFYTE" b2="230 KV" b3="08L-ATT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08LAFYTE" b2="230 KV" b3="27-B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08LAFYTE" b2="230 KV" b3="B4-27" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ATTICA" b2="230 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="VEEDERSB" b2="230 KV" b3="VEE-ATT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VEEDERSB" b2="230 KV" b3="27-43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VEEDERSB" b2="230 KV" b3="B1-27" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42350</SeqNum>
    <Name>L345.Hills-DiamndBK</Name>
    <LastEdit Timestamp="2025-07-10T19:02:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DIAMNDBK" b2="345 KV" b3="DBK902" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DIAMNDBK" b2="345 KV" b3="DBK903" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLS  6" b2="345 KV" b3="924" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLS  6" b2="345 KV" b3="934" />
      <ContingencyEquipment Action="L" Type="LN" b1="DIAMNDBK" b2="345 KV" b3="DIA-HILL" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HILLS  6" b2="345 KV" b3="REACT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42360</SeqNum>
    <Name>L138.Reynolds-Magnetation(NIPS)</Name>
    <LastEdit Timestamp="2025-08-11T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGNTATN" b2="138 KV" b3="109-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGNTATN" b2="138 KV" b3="847-109" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="138 KV" b3="109-116" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="138 KV" b3="57-109" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAGNTATN" b2="138 KV" b3="MAG-REY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42370</SeqNum>
    <Name>L138.Reynolds-17Godland</Name>
    <LastEdit Timestamp="2025-07-24T10:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="17GODLND" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17GODLND" b2="69 KV" b3="69 XFR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17GODLND" b2="138 KV" b3="BUST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="138 KV" b3="57-109" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="138 KV" b3="57-XFR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="REYNOLD2" b2="138 KV" b3="REY-17G1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42380</SeqNum>
    <Name>L345.Sub91-Davenport (MEC)</Name>
    <LastEdit Timestamp="2026-01-02T11:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DAVNPRT6" b2="345 KV" b3="62201622" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVNPRT6" b2="345 KV" b3="934" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUB 91" b2="345 KV" b3="PCB91944" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42390</SeqNum>
    <Name>L345.Davenport-Wallcott + Davenport.TR1 (MEC)</Name>
    <LastEdit Timestamp="2025-10-09T12:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVNPRT6" b2="161 KV" b3="8144" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVNPRT6" b2="161 KV" b3="8154" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVNPRT6" b2="345 KV" b3="934" />
      <ContingencyEquipment Action="X" Type="XF" b1="DAVNPRT6" b2="345 KV" b3="9T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAVNPRT6" b2="345 KV" b3="LN  4418" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALCOTT6" b2="345 KV" b3="934" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALCOTT6" b2="345 KV" b3="944" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42410</SeqNum>
    <Name>L345.Brokaw-Clinton</Name>
    <LastEdit Timestamp="2026-05-15T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLINTON4" b2="345 KV" b3="4535" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="345 KV" b3="4550" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="345 KV" b3="4553" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON4" b2="345 KV" b3="BT4502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON4" b2="345 KV" b3="BT4506" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42440</SeqNum>
    <Name>L138.197Grenshaw-745ICAir.19714</Name>
    <LastEdit Timestamp="2025-06-24T13:09:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="197 GREN" b2="138 KV" b3="19714" />
      <ContingencyEquipment Action="OP" Type="CB" b1="197 GREN" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="197 GREN" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="745 IC A" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42470</SeqNum>
    <Name>L230.LakeNelson-Kilmer-Sayreville.I1023</Name>
    <LastEdit Timestamp="2025-12-10T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KILMER" b2="230 KV" b3="KIL-LAKI" />
      <ContingencyEquipment Action="L" Type="LN" b1="KILMER" b2="230 KV" b3="KIL-SAYI" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KILMER" b2="230 KV" b3="T12TRANS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KILMER" b2="230 KV" b3="T34TRANS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KILMER" b2="230 KV" b3="TRAN T-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KILMER" b2="230 KV" b3="TRAN T-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKENELS" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKENELS" b2="230 KV" b3="I1023 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42480</SeqNum>
    <Name>L230.Gillette-GB-MidSx-Bridgewater-LakeNels.I-1023</Name>
    <LastEdit Timestamp="2025-06-05T10:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEWA" b2="230 KV" b3="1-8CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEWA" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIDGEWA" b2="230 KV" b3="BRI-MID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILLETTE" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GILLETTE" b2="230 KV" b3="GIL-GREI" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENBRO" b2="230 KV" b3="GRE-MID" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="GREENBRO" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENBRO" b2="230 KV" b3="TRANT-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKENELS" b2="230 KV" b3="I1023 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKENELS" b2="230 KV" b3="LAK-MID" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LAKENELS" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKENELS" b2="230 KV" b3="TRANT2CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42490</SeqNum>
    <Name>L138.Havana-CastroIP</Name>
    <LastEdit Timestamp="2026-05-14T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CASTROIP" b2="138 KV" b3="CAS-HAVA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CASTROIP" b2="138 KV" b3="H10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CASTROIP" b2="138 KV" b3="H8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAVANA 3" b2="138 KV" b3="H6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42550</SeqNum>
    <Name>L138.197Grenshaw-745ICAir.19711</Name>
    <LastEdit Timestamp="2025-06-26T11:43:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="197 GREN" b2="138 KV" b3="19711" />
      <ContingencyEquipment Action="OP" Type="CB" b1="197 GREN" b2="138 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="197 GREN" b2="138 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="745 IC A" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42560</SeqNum>
    <Name>L230.Hartman-NorthWales.220-71</Name>
    <LastEdit Timestamp="2025-01-16T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARTMAN" b2="230 KV" b3="715" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARTMAN" b2="230 KV" b3="HAR-NWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWALES" b2="35 KV" b3="70 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWALES" b2="230 KV" b3="705 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="NWALES" b2="230 KV" b3="NW 3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42570</SeqNum>
    <Name>L345.Argenta-Palisades.1 (CONS/ITC)</Name>
    <LastEdit Timestamp="2026-05-11T15:53:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGENTA2" b2="345 KV" b3="30H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGENTA2" b2="345 KV" b3="30R8" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARGENTA2" b2="345 KV" b3="ARG-PAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="29F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="29H9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42580</SeqNum>
    <Name>L345.Argenta-Palisades.2 (CONS/ITC)</Name>
    <LastEdit Timestamp="2026-05-11T15:52:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGENTA2" b2="345 KV" b3="32F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGENTA2" b2="345 KV" b3="32H9" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARGENTA2" b2="345 KV" b3="ARG-PAL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="27H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="27R8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42590</SeqNum>
    <Name>L69.Cromby-Eagle.6904</Name>
    <LastEdit Timestamp="2026-05-14T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="69 KV" b3="945" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROMBY" b2="69 KV" b3="CRO-EAG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLE PE" b2="69 KV" b3="045" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42600</SeqNum>
    <Name>L69.Eagle-Planebrook.6903</Name>
    <LastEdit Timestamp="2026-05-15T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLE PE" b2="69 KV" b3="035" />
      <ContingencyEquipment Action="L" Type="LN" b1="EAGLE PE" b2="69 KV" b3="EAG-PLA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="69 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="69 KV" b3="935" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42610</SeqNum>
    <Name>230/115.Jackson.T5</Name>
    <LastEdit Timestamp="2025-10-16T13:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="230 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="230 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="115 KV" b3="B14" />
      <ContingencyEquipment Action="X" Type="XF" b1="JACK ME" b2="230 KV" b3="BK5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42630</SeqNum>
    <Name>345/138.East Frankfort.TR83</Name>
    <LastEdit Timestamp="2025-08-22T10:09:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="345 KV" b3="BT4A-6CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="66 E FRN" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="66 E FRN" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="66 E FRN" b2="138 KV" b3="TR83CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42640</SeqNum>
    <Name>Linden.CC1</Name>
    <LastEdit Timestamp="2024-12-10T16:12:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="138 KV" b3="1-13" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="138 KV" b3="1001A" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="138 KV" b3="1001B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINDEN" b2="18 KV" b3="1100 ST" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="138 KV" b3="1101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="18 KV" b3="1101 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINDEN" b2="18 KV" b3="1101 CT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="18 KV" b3="1201 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINDEN" b2="18 KV" b3="1201 CT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="138 KV" b3="13-14" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINDEN" b2="18 KV" b3="AUX1101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="18 KV" b3="DUMMYSTM" />
      <ContingencyEquipment Action="S" Type="SD" b1="LINDEN" b2="138 KV" b3="SEREACT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42650</SeqNum>
    <Name>Linden.CC2 (2x1)</Name>
    <LastEdit Timestamp="2024-06-12T15:02:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="LINDEN" b2="18 KV" b3="2001 GEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="18 KV" b3="2001 LS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="18 KV" b3="2101 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINDEN" b2="18 KV" b3="2101 CT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="18 KV" b3="2201 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINDEN" b2="18 KV" b3="2201 CT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42660</SeqNum>
    <Name>L138.11107-111 Elec Jn-539 Warrenville-W600 Ess</Name>
    <LastEdit Timestamp="2026-05-15T10:36:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="L11107CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="11107" b2="138 KV" b3="11107 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="11107" b2="138 KV" b3="11107 2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="539 WVIL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="539 WVIL" b2="138 KV" b3="L11107CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="11107" b2="138 KV" b3="11107 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W600" b2="138 KV" b3="L11107CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42680</SeqNum>
    <Name>L765.Wyoming-JacksonsFerry</Name>
    <LastEdit Timestamp="2026-04-27T14:46:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="765 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="765 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSONS" b2="765 KV" b3="JAC-WYO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="765 KV" b3="O" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="765 KV" b3="R" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WYOMING2" b2="765 KV" b3="R2A" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WYOMING2" b2="765 KV" b3="R2B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WYOMING2" b2="765 KV" b3="R2C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="765 KV" b3="RB2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WYOMING2" b2="765 KV" b3="RB5SPABC" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WYOMING2" b2="765 KV" b3="RSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42710</SeqNum>
    <Name>L230.IndianRiver-Milford.23034</Name>
    <LastEdit Timestamp="2025-02-26T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="230 KV" b3="235" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="230 KV" b3="236" />
      <ContingencyEquipment Action="L" Type="LN" b1="INDIANRI" b2="230 KV" b3="IND-MIL4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="230 KV" b3="9310" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42720</SeqNum>
    <Name>L69.Court-LakeAvenue-Middle</Name>
    <LastEdit Timestamp="2025-05-20T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COURT" b2="69 KV" b3="COU-MID" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COURT" b2="69 KV" b3="DIS G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVEN" b2="69 KV" b3="AW" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEAVEN" b2="69 KV" b3="LAK-MIDT" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDD AE" b2="69 KV" b3="MID-MDT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD AE" b2="69 KV" b3="OCB B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42740</SeqNum>
    <Name>L69.RioGrande-CapeMay.0737</Name>
    <LastEdit Timestamp="2026-01-16T13:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CAPEMAY" b2="69 KV" b3="CAP-RIO7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPEMAY" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPEMAY" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIOGRAND" b2="69 KV" b3="AW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIOGRAND" b2="69 KV" b3="BV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42750</SeqNum>
    <Name>L69.RioGrande-CapeMay.0735</Name>
    <LastEdit Timestamp="2026-01-16T13:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CAPEMAY" b2="69 KV" b3="CAP-RIO5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPEMAY" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPEMAY" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIOGRAND" b2="69 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIOGRAND" b2="69 KV" b3="U" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42760</SeqNum>
    <Name>L69.Middle-LakeAvenue.0736</Name>
    <LastEdit Timestamp="2025-09-08T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAKEAVEN" b2="69 KV" b3="ABS CC" />
      <ContingencyEquipment Action="CL" Type="CB" b1="LAKEAVEN" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEAVEN" b2="69 KV" b3="LAK-MID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVEN" b2="69 KV" b3="N_" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD AE" b2="69 KV" b3="OCB D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42770</SeqNum>
    <Name>L69.Corson-SeaIsle.0780</Name>
    <LastEdit Timestamp="2025-11-30T18:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORSON" b2="69 KV" b3="COR-SEA0" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORSON" b2="69 KV" b3="OCB C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEAISLE" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="CL" Type="CB" b1="SEAISLE" b2="69 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42780</SeqNum>
    <Name>L69.Corson-SeaIsle-Swainton.0717</Name>
    <LastEdit Timestamp="2025-04-29T17:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORSON" b2="69 KV" b3="COR-SEA7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORSON" b2="69 KV" b3="OCB K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COURT" b2="69 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEAISLE" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEAISLE" b2="69 KV" b3="SEA-SWA" />
      <ContingencyEquipment Action="L" Type="LN" b1="COURT" b2="69 KV" b3="COU-SWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWAINTON" b2="69 KV" b3="OCB F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42790</SeqNum>
    <Name>(NUKE)Limerick.U1</Name>
    <LastEdit Timestamp="2024-10-10T13:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="230 KV" b3="535 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="230 KV" b3="635 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="500 KV" b3="DUMNUK10" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="500 KV" b3="DUMNUK13" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="230 KV" b3="DUMNUK16" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="500 KV" b3="DUMNUKE1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="230 KV" b3="DUMNUKE2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="230 KV" b3="DUMNUKE3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="230 KV" b3="DUMNUKE4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="500 KV" b3="DUMNUKE4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="230 KV" b3="DUMNUKE5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="500 KV" b3="DUMNUKE5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="230 KV" b3="DUMNUKE7" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="500 KV" b3="DUMNUKE7" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="230 KV" b3="DUMNUKE8" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="500 KV" b3="DUMNUKE9" />
      <ContingencyEquipment Action="X" Type="XF" b1="LIMERICK" b2="230 KV" b3="LIM1UNT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LIMERICK" b2="20 KV" b3="UNIT01" />
      <ContingencyEquipment Action="CL" Type="CB" b1="LIMERTAP" b2="69 KV" b3="805" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERTAP" b2="69 KV" b3="DUMNUKE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42800</SeqNum>
    <Name>(NUKE)Limerick.U2</Name>
    <LastEdit Timestamp="2024-10-10T13:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="500 KV" b3="235 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="500 KV" b3="335 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="500 KV" b3="DUMNUK10" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="500 KV" b3="DUMNUK13" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="230 KV" b3="DUMNUK16" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="500 KV" b3="DUMNUKE1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="230 KV" b3="DUMNUKE2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="230 KV" b3="DUMNUKE3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="230 KV" b3="DUMNUKE4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="500 KV" b3="DUMNUKE4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="230 KV" b3="DUMNUKE5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="500 KV" b3="DUMNUKE5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="230 KV" b3="DUMNUKE7" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="230 KV" b3="DUMNUKE8" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERICK" b2="500 KV" b3="DUMNUKE9" />
      <ContingencyEquipment Action="X" Type="XF" b1="LIMERICK" b2="500 KV" b3="LIM2UNT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LIMERICK" b2="20 KV" b3="UNIT02" />
      <ContingencyEquipment Action="CL" Type="CB" b1="LIMERTAP" b2="69 KV" b3="805" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LIMERTAP" b2="69 KV" b3="DUMNUKE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42810</SeqNum>
    <Name>L345.Coffeen-Diaz (Ameren)</Name>
    <LastEdit Timestamp="2025-07-29T07:46:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COFFEN 3" b2="345 KV" b3="3542" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COFFEN 3" b2="345 KV" b3="3543" />
      <ContingencyEquipment Action="L" Type="LN" b1="COFFEN 3" b2="345 KV" b3="COF-DIAZ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DIAZ" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DIAZ" b2="345 KV" b3="V15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42830</SeqNum>
    <Name>L230.PeachBottom-MuddyRun.220-06 &amp; MuddyRun.U1-4</Name>
    <LastEdit Timestamp="2026-05-15T10:38:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUDDYRN" b2="230 KV" b3="065 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MUDDYRN" b2="230 KV" b3="MR 1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="MUDDYRN" b2="230 KV" b3="MR 2TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="MUDDYRN" b2="230 KV" b3="MUD-PEA6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="230 KV" b3="345 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="230 KV" b3="675 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42840</SeqNum>
    <Name>L500.Phippsbend-Sullivan (TVA)</Name>
    <LastEdit Timestamp="2026-05-15T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PHIPPB" b2="500 KV" b3="5074" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHIPPB" b2="500 KV" b3="5078" />
      <ContingencyEquipment Action="L" Type="LN" b1="PHIPPB" b2="500 KV" b3="PHI-SUL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA" b2="500 KV" b3="5024" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SULLIVA" b2="500 KV" b3="5027" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42850</SeqNum>
    <Name>L500.Volunteer-WBNP (TVA)</Name>
    <LastEdit Timestamp="2026-05-15T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="WBNP" b2="500 KV" b3="32236A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VOLUNTE" b2="500 KV" b3="5064" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VOLUNTE" b2="500 KV" b3="5068" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBNP" b2="500 KV" b3="5104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBNP" b2="500 KV" b3="5108" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42860</SeqNum>
    <Name>L500.Bullrun-Volunteer (TVA)</Name>
    <LastEdit Timestamp="2026-05-15T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="VOLUNTE" b2="500 KV" b3="32238A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRU" b2="500 KV" b3="5214" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRU" b2="500 KV" b3="5224" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VOLUNTE" b2="500 KV" b3="5044" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VOLUNTE" b2="500 KV" b3="5048" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42870</SeqNum>
    <Name>L500.Phippsbend-Volunteer (TVA)</Name>
    <LastEdit Timestamp="2026-05-15T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PHIPPB" b2="500 KV" b3="32200A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHIPPB" b2="500 KV" b3="5064" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHIPPB" b2="500 KV" b3="5068" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VOLUNTE" b2="500 KV" b3="5024" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VOLUNTE" b2="500 KV" b3="5028" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42880</SeqNum>
    <Name>L500.Phippsbend-Pocket (TVA)</Name>
    <LastEdit Timestamp="2024-08-20T11:38:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PHIPPB" b2="500 KV" b3="5034" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHIPPB" b2="500 KV" b3="5038" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCKET_N" b2="500 KV" b3="MOD5005" />
      <ContingencyEquipment Action="L" Type="LN" b1="PHIPPB" b2="500 KV" b3="PHI-PIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42890</SeqNum>
    <Name>L500.Bullrun-8Anderson (TVA)</Name>
    <LastEdit Timestamp="2026-04-14T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="8ANDERSO" b2="500 KV" b3="5018" />
      <ContingencyEquipment Action="OP" Type="CB" b1="8ANDERSO" b2="500 KV" b3="6016" />
      <ContingencyEquipment Action="L" Type="LN" b1="8ANDERSO" b2="500 KV" b3="AND-BULL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRU" b2="500 KV" b3="5224" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRU" b2="500 KV" b3="5228" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42900</SeqNum>
    <Name>L500.Bullrun-WBNP (TVA)</Name>
    <LastEdit Timestamp="2026-05-15T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="WBNP" b2="500 KV" b3="32235A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRU" b2="500 KV" b3="5218" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRU" b2="500 KV" b3="5228" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBNP" b2="500 KV" b3="5094" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBNP" b2="500 KV" b3="5098" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42910</SeqNum>
    <Name>500/161.Phippsbend.T3 (TVA)</Name>
    <LastEdit Timestamp="2026-05-15T10:39:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="PHIPPB" b2="13 KV" b3="301" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PHIPPB" b2="13 KV" b3="302" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PHIPPB" b2="13 KV" b3="303" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHIPPB" b2="500 KV" b3="5054" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHIPPB" b2="500 KV" b3="5058" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHIPPB" b2="161 KV" b3="864" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHIPPB" b2="161 KV" b3="868" />
      <ContingencyEquipment Action="X" Type="XF" b1="PHIPPB" b2="500 KV" b3="BANK3-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="PHIPPB" b2="161 KV" b3="BANK3-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="PHIPPB" b2="13 KV" b3="BANK3-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42920</SeqNum>
    <Name>500/161/13.Sullivan.TR3 (TVA)</Name>
    <LastEdit Timestamp="2024-06-13T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SULLIVA" b2="13 KV" b3="2007" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA" b2="500 KV" b3="5054" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA" b2="500 KV" b3="5058" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA" b2="161 KV" b3="884" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA" b2="161 KV" b3="888" />
      <ContingencyEquipment Action="X" Type="XF" b1="SULLIVA" b2="500 KV" b3="BANK3-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SULLIVA" b2="161 KV" b3="BANK3-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SULLIVA" b2="13 KV" b3="BANK3-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42930</SeqNum>
    <Name>500/161.Sullivan.T4 (TVA)</Name>
    <LastEdit Timestamp="2026-05-15T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SULLIVA" b2="161 KV" b3="1091" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA" b2="161 KV" b3="1094" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SULLIVA" b2="13 KV" b3="2017" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA" b2="500 KV" b3="5034" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA" b2="500 KV" b3="5038" />
      <ContingencyEquipment Action="X" Type="XF" b1="SULLIVA" b2="500 KV" b3="BANK4-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SULLIVA" b2="161 KV" b3="BANK4-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SULLIVA" b2="13 KV" b3="BANK4-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42960</SeqNum>
    <Name>500/161.BullRun.TR5</Name>
    <LastEdit Timestamp="2024-12-18T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRU" b2="500 KV" b3="5214" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRU" b2="500 KV" b3="5218" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRU" b2="161 KV" b3="884" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRU" b2="161 KV" b3="888" />
      <ContingencyEquipment Action="X" Type="XF" b1="BULLRU" b2="500 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42980</SeqNum>
    <Name>L138.MtPleasant-Middletown-Townsend.13808</Name>
    <LastEdit Timestamp="2024-10-28T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="MIDDLETO" b2="138 KV" b3="13808C" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDDLETO" b2="138 KV" b3="MID-MTP" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDDLETO" b2="138 KV" b3="MID-TOW" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDDLETO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDDLETO" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTPLEASN" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTPLEASN" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWNSEND" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWNSEND" b2="138 KV" b3="133" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>42990</SeqNum>
    <Name>L138.148WLoop-82Crosby.14826</Name>
    <LastEdit Timestamp="2025-06-24T08:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="148 W LO" b2="138 KV" b3="14826" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1314CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1415CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43000</SeqNum>
    <Name>L138.148WLoop-82Crosby.14828</Name>
    <LastEdit Timestamp="2025-06-24T08:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="148 W LO" b2="138 KV" b3="14828" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT5-18CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT5-6 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43010</SeqNum>
    <Name>L230.NewLondon-Webster</Name>
    <LastEdit Timestamp="2026-05-18T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLONDN" b2="230 KV" b3="1516" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLONDN" b2="230 KV" b3="1609" />
      <ContingencyEquipment Action="L" Type="LN" b1="WEBSTER" b2="230 KV" b3="WEB-NEW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEBSTER" b2="230 KV" b3="16-B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEBSTER" b2="230 KV" b3="20-16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43030</SeqNum>
    <Name>L230.Discovery-Sully.2107</Name>
    <LastEdit Timestamp="2024-05-14T10:39:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DISCOVER" b2="230 KV" b3="21072232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DISCOVER" b2="230 KV" b3="H132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DISCOVER" b2="13 KV" b3="LOAD 1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DISCOVER" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DISCOVER" b2="230 KV" b3="2107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLY" b2="230 KV" b3="265T2107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLY" b2="230 KV" b3="H112" />
      <ContingencyEquipment Action="X" Type="XF" b1="SULLY" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SULLY" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43040</SeqNum>
    <Name>Clinton.U1 (AMRN)</Name>
    <LastEdit Timestamp="2026-05-18T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON4" b2="345 KV" b3="BT4506" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON4" b2="345 KV" b3="BT4510" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLINTON4" b2="345 KV" b3="U CL-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43050</SeqNum>
    <Name>345/138.Rising.TR1 (AMRN)</Name>
    <LastEdit Timestamp="2026-02-27T15:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="RISING" b2="345 KV" b3="45TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="138 KV" b3="H7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="138 KV" b3="H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="345 KV" b3="V15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="345 KV" b3="V25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="345 KV" b3="V35" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43060</SeqNum>
    <Name>L138.Clybourn-W.Loop.14807 G (SPOG 2-22)</Name>
    <LastEdit Timestamp="2025-03-31T00:14:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="13-14 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="148 W LO" b2="138 KV" b3="14807" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT6-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT2-11CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="54 CLYBO" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="54 CLYBO" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43080</SeqNum>
    <Name>L138.148 W Loop-Diversey.14818</Name>
    <LastEdit Timestamp="2026-05-18T10:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="148 W LO" b2="138 KV" b3="14818" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT9-10CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43110</SeqNum>
    <Name>138/69.Worcester.AT1</Name>
    <LastEdit Timestamp="2026-05-19T10:23:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="138 KV" b3="195" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="69 KV" b3="7250" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="69 KV" b3="7260" />
      <ContingencyEquipment Action="X" Type="XF" b1="WORCESTE" b2="138 KV" b3="AT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43130</SeqNum>
    <Name>L345.Arsenal-Carson.307</Name>
    <LastEdit Timestamp="2026-05-18T10:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARSENAL" b2="345 KV" b3="ARS-CAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="345 KV" b3="TIE 1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="345 KV" b3="TIE 4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARS DUQ" b2="345 KV" b3="307" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43140</SeqNum>
    <Name>345/138.Arsenal.T1</Name>
    <LastEdit Timestamp="2024-12-16T17:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ARSENAL" b2="345 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="345 KV" b3="TIE 1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="345 KV" b3="TIE 1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="138 KV" b3="TIE 4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="138 KV" b3="TIE 4-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43150</SeqNum>
    <Name>L345.Petersburg-Thompson</Name>
    <LastEdit Timestamp="2026-05-19T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="4C" />
      <ContingencyEquipment Action="L" Type="LN" b1="PETERSB2" b2="345 KV" b3="PET-THO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOMPSO2" b2="345 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOMPSO2" b2="345 KV" b3="5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43160</SeqNum>
    <Name>L69.Sunbury-Limestone-Laurltwn-Logantwn-Lockhavn.A</Name>
    <LastEdit Timestamp="2026-02-11T16:57:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BEAVRTWN" b2="69 KV" b3="4028" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAURELTO" b2="69 KV" b3="4113_DIS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAURELTO" b2="69 KV" b3="DUMG3" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAURELTO" b2="69 KV" b3="LAU-LOGA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAURELTO" b2="69 KV" b3="LAUR_LD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LIMESTON" b2="69 KV" b3="4331" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVRTWN" b2="69 KV" b3="BEA-LIME" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAURELTO" b2="69 KV" b3="LAU-LIME" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIMESTON" b2="69 KV" b3="LIM-SUNB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LIMESTON" b2="69 KV" b3="LIME" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LIMESTON" b2="69 KV" b3="LIME2_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="LYC1SUNB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="SUN" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOCKHAVE" b2="69 KV" b3="LOC-LOGA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOGANTON" b2="69 KV" b3="LOGA1_LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOGANTON" b2="69 KV" b3="LOGA2_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="LBRGLOHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="LOHA2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43180</SeqNum>
    <Name>L138.Hillsboro-Spickard</Name>
    <LastEdit Timestamp="2024-10-10T15:05:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSBOR" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSBOR" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLSBOR" b2="138 KV" b3="HIL-SPIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPICKARD" b2="138 KV" b3="H014W5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPICKARD" b2="138 KV" b3="H014W8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43190</SeqNum>
    <Name>500/230.Carson.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-18T10:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CARSON4" b2="500 KV" b3="H174M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="230 KV" b3="L172" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARSON4" b2="500 KV" b3="TX1H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43200</SeqNum>
    <Name>500/115.Chancelr.T1</Name>
    <LastEdit Timestamp="2026-05-18T10:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHANCELR" b2="500 KV" b3="H1T552" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHANCELR" b2="115 KV" b3="L192" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHANCELR" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43230</SeqNum>
    <Name>500/230.Clifton.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-18T10:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLIFTON" b2="500 KV" b3="H184M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTON" b2="230 KV" b3="L182" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLIFTON" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43240</SeqNum>
    <Name>500/230.Clover.T9</Name>
    <LastEdit Timestamp="2026-05-18T10:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G2TL9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="500 KV" b3="H9T556" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="L912" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVER" b2="500 KV" b3="TX9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43260</SeqNum>
    <Name>500/230.Dooms.TX7 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-08T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="DOOMS4" b2="500 KV" b3="H744M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="L742" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOOMS4" b2="500 KV" b3="TX7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43270</SeqNum>
    <Name>500/230.Elmont.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-18T10:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELMONT4" b2="500 KV" b3="H294M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="L292" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELMONT4" b2="500 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43280</SeqNum>
    <Name>500/230.Elmont.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-18T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELMONT4" b2="500 KV" b3="H194M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="L192" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="L1T221" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELMONT4" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43290</SeqNum>
    <Name>500/230.Fentress.TX1</Name>
    <LastEdit Timestamp="2026-03-19T14:26:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="500 KV" b3="H122-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="500 KV" b3="H122-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="L122" />
      <ContingencyEquipment Action="X" Type="XF" b1="FENTRES4" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43300</SeqNum>
    <Name>500/230.Fentress.TX3</Name>
    <LastEdit Timestamp="2026-05-26T11:34:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="500 KV" b3="H322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="L322" />
      <ContingencyEquipment Action="X" Type="XF" b1="FENTRES4" b2="500 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43310</SeqNum>
    <Name>500/230.Lexington.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-02T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LEXINGTN" b2="500 KV" b3="H104M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="230 KV" b3="L102" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEXINGTN" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43320</SeqNum>
    <Name>500/230.Lexington.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-18T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LEXINGTN" b2="500 KV" b3="H304M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="230 KV" b3="L302" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEXINGTN" b2="500 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43330</SeqNum>
    <Name>500/230.Loudoun.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-12T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOUDOUN4" b2="500 KV" b3="H154M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="L152" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LOUDOUN4" b2="500 KV" b3="SC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="500 KV" b3="SC152" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOUDOUN4" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43340</SeqNum>
    <Name>500/230.Loudoun.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-18T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOUDOUN4" b2="500 KV" b3="H254M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="L252" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOUDOUN4" b2="500 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43360</SeqNum>
    <Name>500/230.Ox.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-18T10:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="OX4" b2="500 KV" b3="H144M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="L142" />
      <ContingencyEquipment Action="X" Type="XF" b1="OX4" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43370</SeqNum>
    <Name>500/230.Ox.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-18T10:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="OX4" b2="500 KV" b3="H244M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="L242" />
      <ContingencyEquipment Action="X" Type="XF" b1="OX4" b2="500 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43380</SeqNum>
    <Name>500/230.PleasantView.T3</Name>
    <LastEdit Timestamp="2025-03-20T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="500 KV" b3="H322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="230 KV" b3="L3T203" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="230 KV" b3="L3T2180" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLEASNTV" b2="500 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43390</SeqNum>
    <Name>500/230.Possum Point.TX1 (Scntlz)</Name>
    <LastEdit Timestamp="2026-05-18T10:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="POSSUMP4" b2="500 KV" b3="H174M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="L1T2078" />
      <ContingencyEquipment Action="X" Type="XF" b1="POSSUMP4" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43410</SeqNum>
    <Name>500/230.Yadkin.TX2</Name>
    <LastEdit Timestamp="2024-10-14T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="500 KV" b3="H212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="L212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="L2T2105" />
      <ContingencyEquipment Action="X" Type="XF" b1="YADKIN4" b2="500 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43430</SeqNum>
    <Name>L138.Lincoln-Union</Name>
    <LastEdit Timestamp="2026-05-18T10:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN1" b2="138 KV" b3="GCB B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN1" b2="138 KV" b3="GCB E" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLN1" b2="138 KV" b3="LIN-UNI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNION" b2="138 KV" b3="G OCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43440</SeqNum>
    <Name>L138.Sherman-Lincoln</Name>
    <LastEdit Timestamp="2024-10-14T11:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN1" b2="138 KV" b3="GCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN1" b2="138 KV" b3="GCB E" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLN1" b2="138 KV" b3="LIN-SHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERMAN" b2="138 KV" b3="OCB P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43450</SeqNum>
    <Name>345/138.Lanesville.TX1</Name>
    <LastEdit Timestamp="2026-01-02T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANESVL" b2="138 KV" b3="1375" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANESVL" b2="345 KV" b3="BT3586CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANESVL" b2="345 KV" b3="BT3588CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LANESVL" b2="345 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43460</SeqNum>
    <Name>L230.Essex-McCarter.K-2211</Name>
    <LastEdit Timestamp="2026-05-18T10:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="2-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="9-10CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ESSEX" b2="230 KV" b3="ESS-MCC" />
      <ContingencyEquipment Action="P" Type="XF" b1="ESSEX" b2="230 KV" b3="K2211PAR" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ESSEX" b2="230 KV" b3="RCTR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="230 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43470</SeqNum>
    <Name>345/138.Ashtabula.TR4</Name>
    <LastEdit Timestamp="2026-04-17T08:32:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="345 KV" b3="B207" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="345 KV" b3="B249" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="X" Type="XF" b1="ASHTABUL" b2="345 KV" b3="TR-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43540</SeqNum>
    <Name>L500.Bristers-Ox.539</Name>
    <LastEdit Timestamp="2026-01-15T11:05:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRISTERS" b2="500 KV" b3="539" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRISTERS" b2="500 KV" b3="53962-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRISTERS" b2="500 KV" b3="53962-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="500 KV" b3="H1T539" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="500 KV" b3="H2T539" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43550</SeqNum>
    <Name>L500.Bristers-Morrisville.545</Name>
    <LastEdit Timestamp="2025-06-03T09:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRISTERS" b2="500 KV" b3="545" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRISTERS" b2="500 KV" b3="545T552" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRISTERS" b2="500 KV" b3="H1T545" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="500 KV" b3="545T594" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="500 KV" b3="H2T545" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43570</SeqNum>
    <Name>HVDC.Neptune</Name>
    <LastEdit Timestamp="2026-02-11T17:05:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DUFFYAVE" b2="500 KV" b3="1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DUFFYAVE" b2="500 KV" b3="1-GEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUFFYAVE" b2="345 KV" b3="20C01" />
      <ContingencyEquipment Action="X" Type="XF" b1="SAYRECON" b2="500 KV" b3="1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SAYRECON" b2="500 KV" b3="2-PUMP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SAYRECON" b2="230 KV" b3="DCLINEGN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SAYRECON" b2="230 KV" b3="DCLINLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="B27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="B28" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAYRECON" b2="230 KV" b3="SAY-SAY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43580</SeqNum>
    <Name>L138.LumsPond-Reybold.13841</Name>
    <LastEdit Timestamp="2025-02-26T14:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LUMSPOND" b2="138 KV" b3="LUM-REY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMSPOND" b2="138 KV" b3="PCB 131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 136" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 137" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43590</SeqNum>
    <Name>L230.PalmersCorner-PotomacRiver.23109</Name>
    <LastEdit Timestamp="2025-10-21T23:25:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="PALMERS" b2="230 KV" b3="1095R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERS" b2="230 KV" b3="23109B" />
      <ContingencyEquipment Action="L" Type="LN" b1="PALMERS" b2="230 KV" b3="PAL-POT2" />
      <ContingencyEquipment Action="P" Type="XF" b1="POTOMAC" b2="69 KV" b3="6T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="6TSB" />
      <ContingencyEquipment Action="X" Type="XF" b1="POTOMAC" b2="230 KV" b3="STAC-6T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43600</SeqNum>
    <Name>L69.Schuylkill-Waverly</Name>
    <LastEdit Timestamp="2026-05-19T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="110 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="120 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCHUYLKI" b2="69 KV" b3="SCH-WAV" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAVERLY1" b2="69 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY1" b2="69 KV" b3="125" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY1" b2="69 KV" b3="15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43620</SeqNum>
    <Name>L345.Tiffin-Mrgnvly</Name>
    <LastEdit Timestamp="2026-04-16T15:31:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MRGNVLY" b2="345 KV" b3="6951" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MRGNVLY" b2="345 KV" b3="6952" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFIN 6" b2="345 KV" b3="ICK964" />
      <ContingencyEquipment Action="L" Type="LN" b1="MRGNVLY" b2="345 KV" b3="MRG-TIFF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43680</SeqNum>
    <Name>500/35.GreenlandGap.TX1 + GreenlandGapWF.G1</Name>
    <LastEdit Timestamp="2026-03-12T13:35:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENGAP" b2="500 KV" b3="B18" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GREENGAP" b2="35 KV" b3="CAP1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GREENGAP" b2="35 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENGAP" b2="500 KV" b3="GL2" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENGAP" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43710</SeqNum>
    <Name>L230.Churchland-Craney-Tanners-SewellsPoint.2099</Name>
    <LastEdit Timestamp="2026-05-18T10:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRCHLND" b2="230 KV" b3="209952" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHRCHLND" b2="230 KV" b3="2099A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRCHLND" b2="230 KV" b3="226T2099" />
      <ContingencyEquipment Action="L" Type="LN" b1="TANNERPT" b2="230 KV" b3="2099B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRANYISL" b2="230 KV" b3="2099C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="230 KV" b3="20822099" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEWELLPT" b2="230 KV" b3="2099D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="230 KV" b3="H5T2099" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43760</SeqNum>
    <Name>345/138.SouthEastCanton.T1</Name>
    <LastEdit Timestamp="2025-05-28T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SECANTON" b2="345 KV" b3="M1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SECANTON" b2="345 KV" b3="XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43830</SeqNum>
    <Name>345/138.Bixby.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-07T10:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="138 KV" b3="109" />
      <ContingencyEquipment Action="X" Type="XF" b1="BIXBY" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BIXBY" b2="345 KV" b3="X2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43850</SeqNum>
    <Name>345/35.Cook.T5</Name>
    <LastEdit Timestamp="2026-05-18T10:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="COOK" b2="345 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="34 KV" b3="BE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="J1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43860</SeqNum>
    <Name>345/138.JacksonRoad.T5</Name>
    <LastEdit Timestamp="2024-10-31T08:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="345 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="345 KV" b3="E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="138 KV" b3="J1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="138 KV" b3="J2" />
      <ContingencyEquipment Action="X" Type="XF" b1="JACKSONR" b2="345 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43870</SeqNum>
    <Name>L115.SouthJustice-DawsonsCrossRd-BynumsBridge.1015</Name>
    <LastEdit Timestamp="2025-06-11T08:12:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BYNMSBRD" b2="115 KV" b3="10151070" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BYNMSBRD" b2="115 KV" b3="10151084" />
      <ContingencyEquipment Action="L" Type="LN" b1="BYNMSBRD" b2="115 KV" b3="BYN-DAWS" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAWSONCR" b2="115 KV" b3="DAW-SJUS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAWSONCR" b2="115 KV" b3="DP1LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SJUSTICE" b2="115 KV" b3="10151024" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SJUSTICE" b2="115 KV" b3="81T1015" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43890</SeqNum>
    <Name>L345.Cook-BentonHarbor</Name>
    <LastEdit Timestamp="2024-10-14T11:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENTONHA" b2="345 KV" b3="BEN-COO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="N1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43910</SeqNum>
    <Name>345/138.KenzieCreek.T1</Name>
    <LastEdit Timestamp="2024-12-26T15:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="138 KV" b3="F1" />
      <ContingencyEquipment Action="X" Type="XF" b1="KENZIECR" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43930</SeqNum>
    <Name>L345.KenzieCreek-TwinBranch</Name>
    <LastEdit Timestamp="2024-12-30T14:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENZIECR" b2="345 KV" b3="KEN-TWI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="345 KV" b3="L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="345 KV" b3="LM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>43990</SeqNum>
    <Name>345/138.Desoto.T1</Name>
    <LastEdit Timestamp="2024-12-03T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DESOTO" b2="345 KV" b3=".  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="345 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="K2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44010</SeqNum>
    <Name>345/138.Sorenson.T1</Name>
    <LastEdit Timestamp="2026-05-18T10:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SORENSON" b2="345 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SORENSON" b2="138 KV" b3="1-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="P2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44030</SeqNum>
    <Name>765/500.Belmont.T5 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-07T00:42:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELMONT" b2="765 KV" b3="5TX 765" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="500 KV" b3="BL10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="500 KV" b3="BL12" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELMONT" b2="765 KV" b3="TRAN  5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44040</SeqNum>
    <Name>345/69.SouthBerwick.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-19T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SBERWICK" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBERWICK" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SBERWICK" b2="345 KV" b3="X1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44050</SeqNum>
    <Name>L345.SouthBerwick-FostoriaCentral</Name>
    <LastEdit Timestamp="2026-05-21T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTORIA" b2="345 KV" b3="FOS-SBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBERWICK" b2="345 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44060</SeqNum>
    <Name>L345.SouthBerwick-Galion</Name>
    <LastEdit Timestamp="2026-05-19T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="345 KV" b3="159" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="345 KV" b3="63" />
      <ContingencyEquipment Action="L" Type="LN" b1="GALION" b2="345 KV" b3="GAL-SBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBERWICK" b2="345 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44070</SeqNum>
    <Name>345/138.Olive.T2</Name>
    <LastEdit Timestamp="2025-05-02T12:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="OLIVE" b2="345 KV" b3="2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="OLIVE" b2="138 KV" b3="2-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="138 KV" b3="P2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44090</SeqNum>
    <Name>L230.Cumberland-Dennis</Name>
    <LastEdit Timestamp="2024-10-14T11:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="230 KV" b3="BUSGCBC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="230 KV" b3="BUSGCBU" />
      <ContingencyEquipment Action="L" Type="LN" b1="CUMB AE" b2="230 KV" b3="CUM-DEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="230 KV" b3="GCB F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="230 KV" b3="GCB G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44100</SeqNum>
    <Name>230/138.Dennis.T2</Name>
    <LastEdit Timestamp="2025-09-08T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="138 KV" b3="GCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="230 KV" b3="GCB D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="230 KV" b3="GCB F" />
      <ContingencyEquipment Action="X" Type="XF" b1="DENNIS" b2="230 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44120</SeqNum>
    <Name>L230.LimeKiln-Montgomery</Name>
    <LastEdit Timestamp="2026-05-21T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LIMEKILN" b2="230 KV" b3="LIM-MONT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="230 KV" b3="MONTGOME" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTGOME" b2="230 KV" b3="RD207JCT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44140</SeqNum>
    <Name>765/138.Rockport.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-12-02T14:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKPOR2" b2="765 KV" b3="3-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKPOR2" b2="138 KV" b3="3-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPOR2" b2="138 KV" b3="701" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPOR2" b2="34 KV" b3="P CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROCKPOR2" b2="765 KV" b3="X3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44170</SeqNum>
    <Name>L345.Sporn-MercerBottom</Name>
    <LastEdit Timestamp="2025-12-03T13:20:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCERSB" b2="345 KV" b3="A008H5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCERSB" b2="345 KV" b3="A008H8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="BB1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERCERSB" b2="345 KV" b3="MER-SPO1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44190</SeqNum>
    <Name>345/138.TriState.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-13T13:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TRISTATE" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TRISTATE" b2="345 KV" b3="X3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44200</SeqNum>
    <Name>345/138.Sporn.T3</Name>
    <LastEdit Timestamp="2026-05-19T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SPORNAEP" b2="345 KV" b3=".  3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="KK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="KK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="V" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="V2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44210</SeqNum>
    <Name>345/138.Sporn.T-B (Sctlnz)</Name>
    <LastEdit Timestamp="2025-03-17T14:20:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SPORNAEP" b2="345 KV" b3="B-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPORNAEP" b2="138 KV" b3="B-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPORNAEP" b2="13.2 KV" b3="B-T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPORNAEP" b2="13.2 KV" b3="BT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SPORNAEP" b2="345 KV" b3="XB1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44220</SeqNum>
    <Name>345/138.Sporn.T4</Name>
    <LastEdit Timestamp="2026-05-19T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SPORNAEP" b2="345 KV" b3="4-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPORNAEP" b2="138 KV" b3="4-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPORNAEP" b2="13.2 KV" b3="4-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="AA2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44230</SeqNum>
    <Name>345/138.KanawhaRiver.B</Name>
    <LastEdit Timestamp="2024-10-28T12:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="KANAWHAR" b2="345 KV" b3=".  B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="345 KV" b3="BB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="345 KV" b3="BB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="138 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44250</SeqNum>
    <Name>765/138.Wyoming.T3</Name>
    <LastEdit Timestamp="2025-09-03T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="138 KV" b3="J2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="765 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="765 KV" b3="P" />
      <ContingencyEquipment Action="S" Type="SD" b1="WYOMING2" b2="138 KV" b3="R3" />
      <ContingencyEquipment Action="X" Type="XF" b1="WYOMING2" b2="765 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44260</SeqNum>
    <Name>765/138.Wyoming.T4</Name>
    <LastEdit Timestamp="2025-11-03T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="138 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="765 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYOMING2" b2="765 KV" b3="R" />
      <ContingencyEquipment Action="S" Type="SD" b1="WYOMING2" b2="138 KV" b3="R4" />
      <ContingencyEquipment Action="X" Type="XF" b1="WYOMING2" b2="765 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44280</SeqNum>
    <Name>345/138.WestBellaire.T3</Name>
    <LastEdit Timestamp="2026-05-19T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="345 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="345 KV" b3="N2" />
      <ContingencyEquipment Action="X" Type="XF" b1="WBELLAI2" b2="345 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44290</SeqNum>
    <Name>345/138.OhioCentral.T1</Name>
    <LastEdit Timestamp="2025-02-28T12:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="345 KV" b3="K1" />
      <ContingencyEquipment Action="X" Type="XF" b1="OHIOCENT" b2="345 KV" b3="T1 XFMR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44300</SeqNum>
    <Name>L345.OhioCentral-Galion</Name>
    <LastEdit Timestamp="2026-05-19T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="345 KV" b3="162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="345 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="345 KV" b3="M2" />
      <ContingencyEquipment Action="L" Type="LN" b1="OHIOCENT" b2="345 KV" b3="OHI-GAL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44320</SeqNum>
    <Name>345/138.RobisonPark.T5</Name>
    <LastEdit Timestamp="2024-10-28T12:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ROBISONP" b2="345 KV" b3=".  5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="G3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="345 KV" b3="K1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="345 KV" b3="KM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44330</SeqNum>
    <Name>L345.RPMone-AllenIM</Name>
    <LastEdit Timestamp="2026-05-21T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENIM" b2="345 KV" b3="ALL-RPM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="345 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RPMONE" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RPMONE" b2="345 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44350</SeqNum>
    <Name>L345.FallCreek-Noblesville (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-23T16:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FALLCREE" b2="345 KV" b3="FAL-NOB1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FALLCREE" b2="345 KV" b3="W" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NOBLESVI" b2="345 KV" b3="19DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44370</SeqNum>
    <Name>765/138.Maliszewski.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-14T18:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MALISZEW" b2="765 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MALISZEW" b2="138 KV" b3="L1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MALISZEW" b2="138 KV" b3="M1" />
      <ContingencyEquipment Action="S" Type="SD" b1="MALISZEW" b2="138 KV" b3="ORANGE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MALISZEW" b2="138 KV" b3="P1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MALISZEW" b2="765 KV" b3="X1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44390</SeqNum>
    <Name>230/138.Cardiff.T6</Name>
    <LastEdit Timestamp="2026-05-20T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="AW CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="BV CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARDIFF" b2="230 KV" b3="T6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44400</SeqNum>
    <Name>L138.Cardiff-Lewis.1418</Name>
    <LastEdit Timestamp="2024-12-03T14:12:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARDIFF" b2="138 KV" b3="CAR-LEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="138 KV" b3="OCB V" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44440</SeqNum>
    <Name>L230.Manor-Millwood + Mano.T3 + Millwood.T2</Name>
    <LastEdit Timestamp="2024-11-21T09:04:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MANOR" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="230 KV" b3="MLWD_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="230 KV" b3="MLWD_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="230 KV" b3="TRAN3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="TRAN_3-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="TRAN_3-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLWDPL" b2="230 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANOR" b2="230 KV" b3="MAN-MIL" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILLWDPL" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLWDPL" b2="69 KV" b3="T2 LS CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44450</SeqNum>
    <Name>L230.Limekiln-Monocacy.222</Name>
    <LastEdit Timestamp="2024-10-25T13:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LIMEKILN" b2="230 KV" b3="LIM-MONO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="230 KV" b3="MONOCACY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONOCACY" b2="230 KV" b3="LIMEKILN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44460</SeqNum>
    <Name>Ghent_LG.U01 (LGEE)</Name>
    <LastEdit Timestamp="2026-05-20T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="138 KV" b3="712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="138 KV" b3="B165_716" />
      <ContingencyEquipment Action="X" Type="XF" b1="GHENT_LG" b2="138 KV" b3="GH1GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GHENT_LG" b2="18 KV" b3="GHENT01" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44470</SeqNum>
    <Name>L115.Conemaugh-Seward.1065 + Conemaugh.Diesel</Name>
    <LastEdit Timestamp="2025-01-06T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CONEMAUG" b2="115 KV" b3="CNM-SEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONEMAUG" b2="115 KV" b3="DIESELCB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONEMAUG" b2="115 KV" b3="START" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="115 KV" b3="B117" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="115 KV" b3="B118" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44480</SeqNum>
    <Name>Palisades.U1 (ITC)</Name>
    <LastEdit Timestamp="2026-05-19T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="25F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="25H9" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PALISAD2" b2="22 KV" b3="PA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44490</SeqNum>
    <Name>Campbell.U3 (ITC)</Name>
    <LastEdit Timestamp="2026-05-20T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPBELL" b2="345 KV" b3="32H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPBELL" b2="345 KV" b3="32R8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPBELL" b2="345 KV" b3="39T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPBELL" b2="345 KV" b3="39T2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CAMPBELL" b2="18 KV" b3="CA3 CONS" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CAMPBELL" b2="18 KV" b3="CA3 MPPA" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CAMPBELL" b2="18 KV" b3="CA3 WPSC" />
      <ContingencyEquipment Action="X" Type="XF" b1="CAMPBELL" b2="345 KV" b3="T31" />
      <ContingencyEquipment Action="X" Type="XF" b1="CAMPBELL" b2="345 KV" b3="T32" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44500</SeqNum>
    <Name>L345.153Taylor-148WLoop.15323</Name>
    <LastEdit Timestamp="2026-05-19T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="153 TAYL" b2="345 KV" b3="15323" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="345 KV" b3="6-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="345 KV" b3="7-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="345 KV" b3="BT5-6 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44510</SeqNum>
    <Name>345/138.148WLoop.TR81</Name>
    <LastEdit Timestamp="2026-05-20T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="345 KV" b3="7-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="345 KV" b3="9-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT1-6 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="148 W LO" b2="345 KV" b3="TR81M-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="148 W LO" b2="138 KV" b3="TR81M-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44520</SeqNum>
    <Name>345/138.148WLoop.TR82</Name>
    <LastEdit Timestamp="2026-05-20T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="13-14 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="345 KV" b3="6-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT1213CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="148 W LO" b2="345 KV" b3="TR82M-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="148 W LO" b2="138 KV" b3="TR82M-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44540</SeqNum>
    <Name>L345.Palisades-Vergennes</Name>
    <LastEdit Timestamp="2025-02-10T11:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="29H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="29R8" />
      <ContingencyEquipment Action="L" Type="LN" b1="PALISAD2" b2="345 KV" b3="PAL-VER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VERGENNE" b2="345 KV" b3="30F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VERGENNE" b2="345 KV" b3="30H9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44560</SeqNum>
    <Name>230/69.QuinceOrchard.T1</Name>
    <LastEdit Timestamp="2024-10-11T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="QUINCEOR" b2="230 KV" b3="118-1T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23023B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23028B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23033B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="69 KV" b3="69K2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="69 KV" b3="69K3B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44570</SeqNum>
    <Name>230/69.QuinceOrchard.T4</Name>
    <LastEdit Timestamp="2026-05-19T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="QUINCEOR" b2="230 KV" b3="118-4T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23024" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23029B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="230 KV" b3="23034B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="69 KV" b3="69K10B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINCEOR" b2="69 KV" b3="69K9B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44610</SeqNum>
    <Name>345/138.155Nelson.TR81</Name>
    <LastEdit Timestamp="2026-01-02T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT1-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="155 NELS" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="155 NELS" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44630</SeqNum>
    <Name>345/138.Twinbranch.T6&amp;T7</Name>
    <LastEdit Timestamp="2026-05-20T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="345 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="345 KV" b3="H2" />
      <ContingencyEquipment Action="X" Type="XF" b1="TWINBRAN" b2="345 KV" b3="T-6" />
      <ContingencyEquipment Action="X" Type="XF" b1="TWINBRAN" b2="345 KV" b3="T-7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44640</SeqNum>
    <Name>138/69/34.RobisonPark.T4</Name>
    <LastEdit Timestamp="2026-05-19T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ROBISONP" b2="138 KV" b3="4-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROBISONP" b2="69 KV" b3="4-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROBISONP" b2="34 KV" b3="4-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="69 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="34 KV" b3="Q" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44660</SeqNum>
    <Name>345/138.EastLima.T2</Name>
    <LastEdit Timestamp="2026-05-19T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ELIMA" b2="345 KV" b3="2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELIMA" b2="138 KV" b3="2-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="345 KV" b3="M1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44670</SeqNum>
    <Name>345/138.EastLima.T1</Name>
    <LastEdit Timestamp="2026-05-19T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ELIMA" b2="345 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELIMA" b2="138 KV" b3="1-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="345 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="345 KV" b3="R2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44710</SeqNum>
    <Name>345/138.13 Crawford.TR81</Name>
    <LastEdit Timestamp="2025-04-22T11:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B719 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B720 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="13 CRAWF" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="13 CRAWF" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44720</SeqNum>
    <Name>345/138.13 Crawford.TR83</Name>
    <LastEdit Timestamp="2025-04-22T11:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT9-16CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="13 CRAWF" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="13 CRAWF" b2="138 KV" b3="TR83CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44770</SeqNum>
    <Name>345/138.13 Crawford.TR82</Name>
    <LastEdit Timestamp="2025-04-22T11:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT1-2GCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="13 CRAWF" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="13 CRAWF" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44780</SeqNum>
    <Name>L345.13Crawford-148WestLoop.1309</Name>
    <LastEdit Timestamp="2026-05-21T09:47:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="13 CRAWF" b2="345 KV" b3="1309" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="345 KV" b3="9-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44790</SeqNum>
    <Name>L345.937LeeCo-959EasyRoad.93702 + BigSky.WF</Name>
    <LastEdit Timestamp="2025-04-23T16:20:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="937 LEE" b2="138 KV" b3="95901" />
      <ContingencyEquipment Action="OP" Type="CB" b1="937 LEE" b2="345 KV" b3="BT1-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="937 LEE" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="937 LEE" b2="345 KV" b3="CBBS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="937 LEE" b2="138 KV" b3="CBBS2" />
      <ContingencyEquipment Action="X" Type="XF" b1="937 LEE" b2="345 KV" b3="TR81" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="959ERDBS" b2="34.5 KV" b3="131" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="959ERDBS" b2="34.5 KV" b3="132" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="959ERDBS" b2="34.5 KV" b3="133" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="959ERDBS" b2="34.5 KV" b3="134" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="959ERDBS" b2="34.5 KV" b3="135" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="959ERDBS" b2="34.5 KV" b3="231" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="959ERDBS" b2="34.5 KV" b3="232" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="959ERDBS" b2="34.5 KV" b3="233" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="959ERDBS" b2="34.5 KV" b3="234" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="959ERDBS" b2="34.5 KV" b3="235" />
      <ContingencyEquipment Action="U" Type="GEN" b1="959ERDBS" b2="34.5 KV" b3="BSWFBRS1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="959ERDBS" b2="34.5 KV" b3="BSWFZEF3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="959ERDBS" b2="138 KV" b3="L95901CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="959ERDBS" b2="138 KV" b3="TRT1" />
      <ContingencyEquipment Action="X" Type="XF" b1="959ERDBS" b2="138 KV" b3="TRT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44800</SeqNum>
    <Name>500/230.Orchard.T1</Name>
    <LastEdit Timestamp="2025-04-02T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARD" b2="500 KV" b3="GCB B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARD" b2="500 KV" b3="GCB C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARD" b2="230 KV" b3="GCB D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARD" b2="230 KV" b3="GCB E" />
      <ContingencyEquipment Action="X" Type="XF" b1="ORCHARD" b2="500 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44810</SeqNum>
    <Name>L138.Universal-US Steel Illinois.Z-57</Name>
    <LastEdit Timestamp="2026-05-19T10:23:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIVERSA" b2="138 KV" b3="ILL57-T" />
      <ContingencyEquipment Action="L" Type="LN" b1="UNIVERSA" b2="138 KV" b3="UNI-USS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="USSILLIN" b2="138 KV" b3="UNIVERSA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44820</SeqNum>
    <Name>230/35.Kittatinny.T4</Name>
    <LastEdit Timestamp="2026-01-21T15:17:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTATIN" b2="230 KV" b3="B32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTATIN" b2="34 KV" b3="B42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTATIN" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTATIN" b2="230 KV" b3="B97" />
      <ContingencyEquipment Action="X" Type="XF" b1="KITTATIN" b2="230 KV" b3="BK 4TR" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="KITTATIN" b2="230 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTATIN" b2="230 KV" b3="TK AC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44830</SeqNum>
    <Name>L138.Cheswick-Wilmerding.Z-51</Name>
    <LastEdit Timestamp="2025-10-15T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHESWICK" b2="138 KV" b3="CHE-WIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWICK" b2="138 KV" b3="WILM51T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILMERDI" b2="138 KV" b3="Z-51" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44840</SeqNum>
    <Name>L230.Bergen-Leonia.K-2289</Name>
    <LastEdit Timestamp="2025-09-16T10:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="19-20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="5-19" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERGEN" b2="230 KV" b3="BER-LEON" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BERGEN" b2="230 KV" b3="RCTR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEONIA" b2="230 KV" b3="SECT 2-3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LEONIA" b2="230 KV" b3="T12TRANS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEONIA" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LEONIA" b2="230 KV" b3="T34TRANS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEONIA" b2="230 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44860</SeqNum>
    <Name>L230.Emilie-FordMill.220-90 + FordMill.2CC</Name>
    <LastEdit Timestamp="2026-05-19T10:26:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="230 KV" b3="905 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EMILIE" b2="230 KV" b3="EMI-FARB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORDMILL" b2="230 KV" b3="2A HI CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FORDMILL" b2="230 KV" b3="2ACT XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORDMILL" b2="230 KV" b3="2B HI CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FORDMILL" b2="230 KV" b3="2BCT XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORDMILL" b2="230 KV" b3="2ST HICB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FORDMILL" b2="230 KV" b3="2STM XF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FORDMILL" b2="18 KV" b3="FE 2ACT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FORDMILL" b2="18 KV" b3="FE 2BCT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FORDMILL" b2="18 KV" b3="FE 2STM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44870</SeqNum>
    <Name>L230.Emilie-FordMill.220-91 + FordMill.1CC</Name>
    <LastEdit Timestamp="2026-05-19T10:27:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="230 KV" b3="915 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EMILIE" b2="230 KV" b3="EMI-FARA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORDMILL" b2="230 KV" b3="1A HI CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FORDMILL" b2="230 KV" b3="1ACT XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORDMILL" b2="230 KV" b3="1B HI CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FORDMILL" b2="230 KV" b3="1BCT XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORDMILL" b2="230 KV" b3="1ST HICB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FORDMILL" b2="230 KV" b3="1STM XF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FORDMILL" b2="18 KV" b3="FE 1ACT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FORDMILL" b2="18 KV" b3="FE 1BCT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FORDMILL" b2="18 KV" b3="FE 1STM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44900</SeqNum>
    <Name>L230.Churchtown-Orchard.2309</Name>
    <LastEdit Timestamp="2024-12-16T17:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="230 KV" b3="BUSGCBC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="230 KV" b3="BUSGCBF" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCHTO" b2="230 KV" b3="CHU-ORC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARD" b2="230 KV" b3="GCB D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARD" b2="230 KV" b3="P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44910</SeqNum>
    <Name>L230.Cumberland-Orchard.2314</Name>
    <LastEdit Timestamp="2024-11-07T10:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="230 KV" b3="BUSGCBA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="230 KV" b3="BUSGCBB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CUMB AE" b2="230 KV" b3="CUM-ORC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARD" b2="230 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARD" b2="230 KV" b3="P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44920</SeqNum>
    <Name>L138.Arsenal-Highland.Z-68</Name>
    <LastEdit Timestamp="2026-05-20T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARSENAL" b2="138 KV" b3="ARS-HIG8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="138 KV" b3="TIE 1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="138 KV" b3="TIE 4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGH DUQ" b2="138 KV" b3="ARSENAL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44950</SeqNum>
    <Name>L138.Arboles-Waverly2</Name>
    <LastEdit Timestamp="2026-01-23T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARBOLES" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARBOLES" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARBOLES" b2="138 KV" b3="ARB-WAVE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY2" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY2" b2="138 KV" b3="104" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44960</SeqNum>
    <Name>L138.SLucasville-NPortsmo</Name>
    <LastEdit Timestamp="2026-05-19T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPORTSMO" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="NPORTSMO" b2="138 KV" b3="NPO-SLU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLUCASVI" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44970</SeqNum>
    <Name>345/138.DonMarquis.T2 + L345.DonMarquis-KygerCreek</Name>
    <LastEdit Timestamp="2024-10-30T14:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="345 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="345 KV" b3="E1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KYGERCRE" b2="345 KV" b3="KYG-MAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="138 KV" b3="N1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARQUIS2" b2="345 KV" b3="XF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>44990</SeqNum>
    <Name>L138.LogansFerry-Universal.Z-152</Name>
    <LastEdit Timestamp="2026-05-21T09:46:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LOGANSFE" b2="138 KV" b3="LOG-UNI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGANSFE" b2="138 KV" b3="UNI152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIVERSA" b2="138 KV" b3="LOGAN152" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45010</SeqNum>
    <Name>L230.SRead-Berks+230/69.SRead.T8&amp;Berks.T1</Name>
    <LastEdit Timestamp="2025-05-22T12:50:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BERKS" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKS" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKS" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERKS" b2="230 KV" b3="BER-SRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKS" b2="69 KV" b3="TRAN_1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SREADING" b2="230 KV" b3="8 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SREADING" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SREADING" b2="69 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SREADING" b2="69 KV" b3="B18" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45030</SeqNum>
    <Name>115/35.Boykins.TX1</Name>
    <LastEdit Timestamp="2024-11-20T15:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOYKINS" b2="115 KV" b3="101732" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOYKINS" b2="115 KV" b3="1017A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOYKINS" b2="115 KV" b3="10832" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOYKINS" b2="115 KV" b3="108A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOYKINS" b2="115 KV" b3="5632" />
      <ContingencyEquipment Action="X" Type="XF" b1="BOYKINS" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOYKINS" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARGARTV" b2="115 KV" b3="56A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45040</SeqNum>
    <Name>L500.NewFreedom-Orchard.5039</Name>
    <LastEdit Timestamp="2024-10-28T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="NEWFREED" b2="500 KV" b3="NEW-ORC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARD" b2="500 KV" b3="GCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARD" b2="500 KV" b3="GCB C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45050</SeqNum>
    <Name>L500.NewFreedom-EastWindsor.5038</Name>
    <LastEdit Timestamp="2025-02-26T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="500 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="500 KV" b3="B16" />
      <ContingencyEquipment Action="L" Type="LN" b1="EWINDSOR" b2="500 KV" b3="EWIN-NEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="500 KV" b3="SECT9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45080</SeqNum>
    <Name>L138.Stonewall-Stephenson</Name>
    <LastEdit Timestamp="2025-01-16T15:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STEPHENS" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="STEPHENS" b2="138 KV" b3="STE-STO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STEPHENS" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STONEWAL" b2="138 KV" b3="STEPHENS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45090</SeqNum>
    <Name>L138.Stephenson-Bartonville</Name>
    <LastEdit Timestamp="2024-09-23T10:02:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BARTONVI" b2="138 KV" b3="1334" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BARTONVI" b2="138 KV" b3="TEMPCAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARTONVI" b2="138 KV" b3="TEMPCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BARTONVI" b2="138 KV" b3="BAR-STE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STEPHENS" b2="138 KV" b3="BARTON" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45100</SeqNum>
    <Name>L138.Meadowbrook-LongCreek</Name>
    <LastEdit Timestamp="2024-10-10T14:45:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGCREE" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGCREE" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONGCREE" b2="138 KV" b3="LON-MEAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45150</SeqNum>
    <Name>L138.Cheswick-Pinecreek.Z-61</Name>
    <LastEdit Timestamp="2026-05-20T17:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHESWICK" b2="138 KV" b3="CHE-PIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWICK" b2="138 KV" b3="PINECK61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINECRK" b2="138 KV" b3="CHESW61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45160</SeqNum>
    <Name>L138.North-Pinecreek.Z-102</Name>
    <LastEdit Timestamp="2026-05-21T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTH" b2="138 KV" b3="PCK_Z102" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINECRK" b2="138 KV" b3="PIN-NOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINECRK" b2="138 KV" b3="NORTH102" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45170</SeqNum>
    <Name>Claytor.CL1</Name>
    <LastEdit Timestamp="2026-05-20T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLAYTOR" b2="11 KV" b3="CL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="11 KV" b3="K" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45180</SeqNum>
    <Name>Claytor.CL2</Name>
    <LastEdit Timestamp="2026-05-20T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLAYTOR" b2="11 KV" b3="CL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="11 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45210</SeqNum>
    <Name>230.Branchburg.CapA&amp;BC</Name>
    <LastEdit Timestamp="2026-05-19T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="BRANCHBU" b2="230 KV" b3="A CAP" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BRANCHBU" b2="230 KV" b3="B CAP" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BRANCHBU" b2="230 KV" b3="C CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="NO 1 CAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45320</SeqNum>
    <Name>L138.Carrcroft-Edgemoor.13824</Name>
    <LastEdit Timestamp="2026-05-20T17:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARRCROF" b2="138 KV" b3="140" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARRCROF" b2="138 KV" b3="141" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARRCROF" b2="138 KV" b3="CAR-EDG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="3-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="3-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45330</SeqNum>
    <Name>L138.Carrcroft-WestWilmington.13826</Name>
    <LastEdit Timestamp="2026-05-20T17:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARRCROF" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARRCROF" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARRCROF" b2="138 KV" b3="CAR-WWI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWILMING" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWILMING" b2="138 KV" b3="134" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45340</SeqNum>
    <Name>L69.Southwark-Waverly</Name>
    <LastEdit Timestamp="2026-05-21T09:49:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SWARK" b2="69 KV" b3="355 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="SWARK" b2="69 KV" b3="SWA-WAV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY1" b2="69 KV" b3="125" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAVERLY1" b2="69 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY1" b2="69 KV" b3="25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45350</SeqNum>
    <Name>L345.LincoGen-LindenVFT</Name>
    <LastEdit Timestamp="2026-02-10T14:54:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOGEN" b2="345 KV" b3="52-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOGEN" b2="345 KV" b3="52-6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINCOGEN" b2="345 KV" b3="NYVFTLD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINCOGEN" b2="345 KV" b3="NY_VFTGN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINVFT" b2="345 KV" b3="CB5_1S" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOGEN" b2="345 KV" b3="LIN-LIN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINVFT" b2="17 KV" b3="NY-VFT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINVFT" b2="17 KV" b3="NY-VFT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINVFT" b2="17 KV" b3="NY-VFT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINVFT" b2="17 KV" b3="PJM-VFT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINVFT" b2="17 KV" b3="PJM-VFT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINVFT" b2="17 KV" b3="PJM-VFT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45370</SeqNum>
    <Name>L138.Polaris-Westar</Name>
    <LastEdit Timestamp="2026-05-21T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POLARIS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="POLARIS" b2="138 KV" b3="POL-WEST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTAR" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45390</SeqNum>
    <Name>RPMone.U1</Name>
    <LastEdit Timestamp="2026-05-21T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="RPMONE" b2="18 KV" b3="1" />
      <ContingencyEquipment Action="X" Type="XF" b1="RPMONE" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RPMONE" b2="345 KV" b3="X1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45400</SeqNum>
    <Name>RPMone.U2</Name>
    <LastEdit Timestamp="2026-05-26T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="RPMONE" b2="18 KV" b3="2" />
      <ContingencyEquipment Action="X" Type="XF" b1="RPMONE" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RPMONE" b2="345 KV" b3="X2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45410</SeqNum>
    <Name>RPMone.U3</Name>
    <LastEdit Timestamp="2026-05-22T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="RPMONE" b2="18 KV" b3="3" />
      <ContingencyEquipment Action="X" Type="XF" b1="RPMONE" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RPMONE" b2="345 KV" b3="X3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45420</SeqNum>
    <Name>SouthRiver.CC</Name>
    <LastEdit Timestamp="2026-03-18T19:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SRIVER" b2="230 KV" b3="1CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SRIVER" b2="230 KV" b3="1CB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SRIVER" b2="230 KV" b3="1CB3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SRIVER" b2="13 KV" b3="G1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SRIVER" b2="13 KV" b3="G2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SRIVER" b2="13 KV" b3="G3" />
      <ContingencyEquipment Action="X" Type="XF" b1="SRIVER" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SRIVER" b2="230 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45430</SeqNum>
    <Name>Lower Mt Bethel.CC</Name>
    <LastEdit Timestamp="2026-05-22T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MARTINSC" b2="230 KV" b3="C1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARTINSC" b2="230 KV" b3="C2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MARTINSC" b2="18 KV" b3="LMB CC1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MARTINSC" b2="18 KV" b3="LMB CT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MARTINSC" b2="18 KV" b3="LMB CT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="LMBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="LMBEPORT" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARTINSC" b2="230 KV" b3="S1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45450</SeqNum>
    <Name>345/138.MuskingumRiver.E</Name>
    <LastEdit Timestamp="2026-05-21T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="138 KV" b3="HG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="138 KV" b3="HJ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SR" />
      <ContingencyEquipment Action="X" Type="XF" b1="MUSKING2" b2="345 KV" b3="XFMR E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45460</SeqNum>
    <Name>345/138.SouthCanton.T1</Name>
    <LastEdit Timestamp="2024-10-28T12:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SCANTON2" b2="345 KV" b3=".  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="K1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="345 KV" b3="XB1H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45470</SeqNum>
    <Name>345/138.Tidd.T-C</Name>
    <LastEdit Timestamp="2024-12-12T13:44:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TIDD_AEP" b2="345 KV" b3="C-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="TIDD_AEP" b2="138 KV" b3="C-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="GG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="GG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="K2" />
      <ContingencyEquipment Action="S" Type="SD" b1="TIDD_AEP" b2="138 KV" b3="SERREAC1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45640</SeqNum>
    <Name>L69.Claymont-Naamans.6834</Name>
    <LastEdit Timestamp="2025-01-23T18:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYMONT" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYMONT" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYMONT" b2="69 KV" b3="CLA-NAA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAAMANS" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAAMANS" b2="69 KV" b3="65" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45650</SeqNum>
    <Name>L69.DarleyRoad-Naamans.6835</Name>
    <LastEdit Timestamp="2026-05-22T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARLEYRD" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARLEYRD" b2="69 KV" b3="66" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARLEYRD" b2="69 KV" b3="DAR-NAA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAAMANS" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAAMANS" b2="69 KV" b3="63" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45660</SeqNum>
    <Name>230/69.Claymont.AT20</Name>
    <LastEdit Timestamp="2025-01-30T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYMONT" b2="230 KV" b3="233" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYMONT" b2="230 KV" b3="235" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYMONT" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYMONT" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLAYMONT" b2="230 KV" b3="AT20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>45670</SeqNum>
    <Name>230/69.Claymont.AT21</Name>
    <LastEdit Timestamp="2025-01-23T18:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYMONT" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYMONT" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYMONT" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYMONT" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLAYMONT" b2="230 KV" b3="AT21" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46270</SeqNum>
    <Name>L230.Brighton-Burtonsville.23014</Name>
    <LastEdit Timestamp="2026-05-22T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="230 KV" b3="2BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIGHTON" b2="230 KV" b3="BRI-BUR4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="23014B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46280</SeqNum>
    <Name>L230.Brighton-Burtonsville.23015</Name>
    <LastEdit Timestamp="2026-05-22T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="230 KV" b3="4BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIGHTON" b2="230 KV" b3="BRI-BUR5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTONSV" b2="230 KV" b3="23015 B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46370</SeqNum>
    <Name>230/34.Gilbert.T11 + Gilbert.U9</Name>
    <LastEdit Timestamp="2025-02-27T14:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBERT" b2="230 KV" b3="1216 GC" />
      <ContingencyEquipment Action="X" Type="XF" b1="GILBERT" b2="230 KV" b3="BK 11-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBERT" b2="34 KV" b3="BK 11GOC" />
      <ContingencyEquipment Action="X" Type="XF" b1="GILBERT" b2="230 KV" b3="BK 16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBERT" b2="34 KV" b3="BK11HOC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBERT" b2="230 KV" b3="C11 OC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GILBERT" b2="18 KV" b3="GEN 9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBERT" b2="18 KV" b3="GEN 9 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46380</SeqNum>
    <Name>L230.Metuchen-Sewaren.Y-2251</Name>
    <LastEdit Timestamp="2025-02-27T10:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="METUCHEN" b2="230 KV" b3="MET-SEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46410</SeqNum>
    <Name>L138.RedLion-Reybold.13802</Name>
    <LastEdit Timestamp="2026-05-22T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="141" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="142" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDLION" b2="138 KV" b3="RED-REY2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 132" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46420</SeqNum>
    <Name>L138.Reybold-DelawareCity.1 + 138/13.DelawarCty.T4</Name>
    <LastEdit Timestamp="2026-05-22T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DELA DPL" b2="138 KV" b3="DEL-REY" />
      <ContingencyEquipment Action="X" Type="XF" b1="DELA DPL" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="13 KV" b3="T4A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 137" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 138" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46430</SeqNum>
    <Name>L138.Reybold-DelawareCity.3 + 138/13.DelawarCty.T3</Name>
    <LastEdit Timestamp="2026-05-22T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DELA DPL" b2="138 KV" b3="DEL-REY3" />
      <ContingencyEquipment Action="X" Type="XF" b1="DELA DPL" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="13 KV" b3="T6A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 130" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46440</SeqNum>
    <Name>L138.HaresCorner-RedLion.13812</Name>
    <LastEdit Timestamp="2026-05-21T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARESCOR" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARESCOR" b2="138 KV" b3="HAR-RED2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARESCOR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="140" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="144" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46450</SeqNum>
    <Name>230/138.RedLion.AT21</Name>
    <LastEdit Timestamp="2026-05-21T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="140" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="141" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDLION" b2="230 KV" b3="21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="245" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="246" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46460</SeqNum>
    <Name>345/138.Conesville.T7</Name>
    <LastEdit Timestamp="2026-05-21T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="345 KV" b3="301C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="345 KV" b3="301S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="138 KV" b3="7C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="138 KV" b3="7N" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONESVIL" b2="345 KV" b3="T7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46470</SeqNum>
    <Name>L230.SunnymeadeRd-Benn-Adams-Brunswk.F-2232</Name>
    <LastEdit Timestamp="2024-10-31T08:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ADAMS" b2="230 KV" b3="ADA-BENF" />
      <ContingencyEquipment Action="L" Type="LN" b1="ADAMS" b2="230 KV" b3="ADA-BRUF" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="ADAMS" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ADAMS" b2="230 KV" b3="TRAN T-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENNETTS" b2="230 KV" b3="BEN-SUN5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BENNETTS" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNETTS" b2="230 KV" b3="T-1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SECT 1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNNYMEA" b2="230 KV" b3="1-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46480</SeqNum>
    <Name>L230.Parrish-Tunnel.220-27</Name>
    <LastEdit Timestamp="2025-04-08T10:11:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PARRISH" b2="230 KV" b3="905 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARRISH" b2="230 KV" b3="935 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="PARRISH" b2="230 KV" b3="PAR-TUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNNEL" b2="230 KV" b3="115 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNNEL" b2="230 KV" b3="125 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TUNNEL" b2="230 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46580</SeqNum>
    <Name>L138.Callow-Master.130-04 + 138/34.Callow.TR1&amp;4&amp;7</Name>
    <LastEdit Timestamp="2024-06-12T15:05:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CALLOWHI" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALLOWHI" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALLOWHI" b2="13 KV" b3="7TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CALLOWHI" b2="138 KV" b3="CAL 1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CALLOWHI" b2="138 KV" b3="CAL 4TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CALLOWHI" b2="138 KV" b3="CAL 7TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CALLOWHI" b2="138 KV" b3="CAL-MAS4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASTER" b2="138 KV" b3="45 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46590</SeqNum>
    <Name>L138.Callow-Master.130-06 + 138/34.Callow.TR3&amp;6&amp;9</Name>
    <LastEdit Timestamp="2024-06-12T15:08:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CALLOWHI" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALLOWHI" b2="13 KV" b3="6TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALLOWHI" b2="13 KV" b3="9TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CALLOWHI" b2="138 KV" b3="CAL 3TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CALLOWHI" b2="138 KV" b3="CAL 6TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CALLOWHI" b2="138 KV" b3="CAL 9TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CALLOWHI" b2="138 KV" b3="CAL-MAS6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASTER" b2="138 KV" b3="65 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46600</SeqNum>
    <Name>L115.Bladensburg-Tuxedo.11511 &amp; 115/13.Bldnsbrg.3</Name>
    <LastEdit Timestamp="2026-05-26T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BLADENSB" b2="115 KV" b3="175-3T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLADENSB" b2="115 KV" b3="3TPL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLADENSB" b2="13 KV" b3="3TSB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLADENSB" b2="115 KV" b3="BLA-TUX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUXEDO" b2="115 KV" b3="11502B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUXEDO" b2="115 KV" b3="11504B" />
      <ContingencyEquipment Action="X" Type="XF" b1="TUXEDO" b2="115 KV" b3="148-2T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUXEDO" b2="13 KV" b3="2TSB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46610</SeqNum>
    <Name>L115.Lanham-Wildercroft.11516</Name>
    <LastEdit Timestamp="2026-05-21T09:52:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="115 KV" b3="11506B" />
      <ContingencyEquipment Action="X" Type="XF" b1="LANHAM" b2="115 KV" b3="149-3T" />
      <ContingencyEquipment Action="X" Type="XF" b1="LANHAM" b2="115 KV" b3="149-6T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="34 KV" b3="3TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="34 KV" b3="3TS3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="13 KV" b3="6TSB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANHAM" b2="115 KV" b3="K2-33B" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANHAM" b2="115 KV" b3="LAN-WIL6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILDERCR" b2="115 KV" b3="3TPL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46620</SeqNum>
    <Name>L230.BurchesHill-Brandywine.23083</Name>
    <LastEdit Timestamp="2026-05-26T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDYWI" b2="230 KV" b3="52TB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRANDYWI" b2="13 KV" b3="CTG_A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRANDYWI" b2="13 KV" b3="CTG_B" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRANDYWI" b2="230 KV" b3="GSU1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRANDYWI" b2="230 KV" b3="GSU2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRANDYWI" b2="230 KV" b3="GSU3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRANDYWI" b2="13 KV" b3="STEAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="6A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="6B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDYWI" b2="230 KV" b3="BRA-BUR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46630</SeqNum>
    <Name>L115.StJohns-StJohnsDP + 230/115.StJohns.TX2</Name>
    <LastEdit Timestamp="2024-10-28T12:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STJOHNDP" b2="115 KV" b3="STJOHNDP" />
      <ContingencyEquipment Action="L" Type="LN" b1="STJOHNS4" b2="115 KV" b3="12A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS4" b2="115 KV" b3="12T47" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS4" b2="230 KV" b3="H262" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS4" b2="115 KV" b3="L2T12" />
      <ContingencyEquipment Action="X" Type="XF" b1="STJOHNS4" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46640</SeqNum>
    <Name>230/115.StJohns.TX2</Name>
    <LastEdit Timestamp="2025-04-29T17:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS4" b2="230 KV" b3="H262" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS4" b2="115 KV" b3="L2T12" />
      <ContingencyEquipment Action="X" Type="XF" b1="STJOHNS4" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46650</SeqNum>
    <Name>L115.BullRun-Harrison.134</Name>
    <LastEdit Timestamp="2025-06-24T08:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRUN" b2="115 KV" b3="13462" />
      <ContingencyEquipment Action="L" Type="LN" b1="BULLRUN" b2="115 KV" b3="134A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BULLRUN" b2="115 KV" b3="134T163" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARRSNDP" b2="115 KV" b3="DP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46660</SeqNum>
    <Name>L115.BullRun-Woods-Stonewall-CannonBranch.163</Name>
    <LastEdit Timestamp="2024-09-26T16:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BULLRUN" b2="115 KV" b3="134T163" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRUN" b2="115 KV" b3="16362" />
      <ContingencyEquipment Action="L" Type="LN" b1="BULLRUN" b2="115 KV" b3="163A3" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANNONBR" b2="115 KV" b3="163B" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CANNONBR" b2="115 KV" b3="163T197" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRSNDP" b2="115 KV" b3="163A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="STONWLDP" b2="115 KV" b3="163A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STONWLDP" b2="115 KV" b3="DP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WOODSDP" b2="115 KV" b3="163A0" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODSDP" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46770</SeqNum>
    <Name>L115.OregonInletDp-PeaIslandTap-Waves-Avon-Buxton</Name>
    <LastEdit Timestamp="2025-01-21T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AVON4" b2="115 KV" b3="10T0105" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVON4" b2="115 KV" b3="AVO-BUX" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVON4" b2="115 KV" b3="AVO-WAV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AVON4" b2="115 KV" b3="AVON4NCE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUXTON" b2="115 KV" b3="10L0147" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUXTON" b2="34.5 KV" b3="BUXTONCE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUXTON" b2="34.5 KV" b3="FRISCNCE" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BUXTON" b2="34.5 KV" b3="GEN12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BUXTON" b2="34.5 KV" b3="GEN34" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BUXTON" b2="34.5 KV" b3="GEN5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BUXTON" b2="34.5 KV" b3="OCRACOK1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUXTON" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NAGSHEAD" b2="115 KV" b3="190A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OREGONDP" b2="115 KV" b3="DP1CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="OREGONDP" b2="115 KV" b3="ORE-PEA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OREGONDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PEAISLAN" b2="115 KV" b3="PEA-WAV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEAISLAN" b2="115 KV" b3="PEATPNCE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVES" b2="115 KV" b3="10T0155" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAVES" b2="115 KV" b3="WAVESNCE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46780</SeqNum>
    <Name>L230.Landstown-WestLanding.2085</Name>
    <LastEdit Timestamp="2026-05-22T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LANDSTWN" b2="230 KV" b3="2085" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="230 KV" b3="20852118" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="230 KV" b3="208552" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTLNDG" b2="230 KV" b3="H112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTLNDG" b2="230 KV" b3="H212" />
      <ContingencyEquipment Action="X" Type="XF" b1="WESTLNDG" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTLNDG" b2="34.5 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WESTLNDG" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTLNDG" b2="34.5 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46790</SeqNum>
    <Name>L230.Waxpool-Roundtable.2149</Name>
    <LastEdit Timestamp="2025-07-07T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTBL" b2="230 KV" b3="214902" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTBL" b2="230 KV" b3="21492214" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAXPOOL" b2="230 KV" b3="214922-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAXPOOL" b2="230 KV" b3="214922-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROUNDTBL" b2="230 KV" b3="2149D1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46810</SeqNum>
    <Name>L230.Yadkin-BowersHill-Churchland.267</Name>
    <LastEdit Timestamp="2026-05-22T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOWERSHL" b2="230 KV" b3="267B" />
      <ContingencyEquipment Action="L" Type="LN" b1="YADKIN4" b2="230 KV" b3="267C" />
      <ContingencyEquipment Action="X" Type="XF" b1="BOWERSHL" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOWERSHL" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRCHLND" b2="230 KV" b3="257T267" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRCHLND" b2="230 KV" b3="26752" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="26712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="267T2158" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46820</SeqNum>
    <Name>L230.Brunswick-DevilsBrook.T2351</Name>
    <LastEdit Timestamp="2024-10-28T12:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="3-15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SEC15-16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEVILSBR" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNSWIC" b2="230 KV" b3="BRU-DEVT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEVILSBR" b2="230 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46830</SeqNum>
    <Name>L138.Ridgeley-Warrior Run</Name>
    <LastEdit Timestamp="2026-05-22T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="RIDGELEY" b2="138 KV" b3="RID-WAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGELEY" b2="138 KV" b3="WARRIORN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRIORN" b2="138 KV" b3="RIDGELEY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46840</SeqNum>
    <Name>L138.FederalStreet-Springdale</Name>
    <LastEdit Timestamp="2025-12-29T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FEDE APS" b2="138 KV" b3="FED-SPR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FEDE APS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="FEDERALS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46850</SeqNum>
    <Name>L138.PittsburghMills-Springdale</Name>
    <LastEdit Timestamp="2025-11-17T15:21:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PITTMILL" b2="138 KV" b3="PIT-SPR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PITTMILL" b2="138 KV" b3="SPRINGDA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="PGMILL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46860</SeqNum>
    <Name>L138.FortMartin-LakeLynn</Name>
    <LastEdit Timestamp="2026-05-21T09:36:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FTMARRES" b2="138 KV" b3="FTM-LAK" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FTMARRES" b2="138 KV" b3="SS LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKELYNN" b2="138 KV" b3="FTMRRES" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46870</SeqNum>
    <Name>L138.Fawn-Silverville</Name>
    <LastEdit Timestamp="2026-05-22T11:55:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FAWN" b2="138 KV" b3="FAW-SIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWN" b2="138 KV" b3="SILVERVI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SILVERVI" b2="138 KV" b3="T62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46880</SeqNum>
    <Name>L138.DutchFork-Enon</Name>
    <LastEdit Timestamp="2024-10-28T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DUTCHFOR" b2="138 KV" b3="DUT-ENO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUTCHFOR" b2="138 KV" b3="ENON" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ENON" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ENON" b2="138 KV" b3="T1A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ENON" b2="138 KV" b3="T1B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ENON" b2="138 KV" b3="T71" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ENON" b2="138 KV" b3="T72" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46890</SeqNum>
    <Name>L138.Donegal-IronBridge</Name>
    <LastEdit Timestamp="2025-06-24T08:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DONEGAL" b2="138 KV" b3="AEC" />
      <ContingencyEquipment Action="L" Type="LN" b1="DONEGAL" b2="138 KV" b3="DON-IRO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DONEGAL" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONBRID" b2="138 KV" b3="DONEGAL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46900</SeqNum>
    <Name>L138.Riverton-Bethel-Viscose</Name>
    <LastEdit Timestamp="2025-01-16T15:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BETHEL" b2="138 KV" b3="BET-RIVF" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHEL" b2="138 KV" b3="BET-VIS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BETHEL" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERTON" b2="138 KV" b3="BETHELVF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VISCOSE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46910</SeqNum>
    <Name>L138.Bedington-Eagle</Name>
    <LastEdit Timestamp="2025-01-27T15:04:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD17" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEDINGTO" b2="138 KV" b3="BED-EAG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLE" b2="34.5 KV" b3="T1LCB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EAGLE" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EAGLE" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="X" Type="XF" b1="EAGLE" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46920</SeqNum>
    <Name>L138.Hardy-Baker</Name>
    <LastEdit Timestamp="2026-05-21T09:45:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAKER1" b2="138 KV" b3="BAK-HAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER1" b2="34.5 KV" b3="T1LCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BAKER1" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDY" b2="138 KV" b3="BAKER1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46930</SeqNum>
    <Name>L115.Cambria-JacksonRoad</Name>
    <LastEdit Timestamp="2024-11-21T14:37:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIA" b2="115 KV" b3="B31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIA" b2="115 KV" b3="B32" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMBRIA" b2="115 KV" b3="CA1-JAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PN" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PN" b2="115 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46940</SeqNum>
    <Name>L115.Cambria-SummitWest</Name>
    <LastEdit Timestamp="2025-10-22T11:50:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIA" b2="115 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIA" b2="115 KV" b3="B35" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="115 KV" b3="B50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="115 KV" b3="B60" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMBRIA" b2="115 KV" b3="CAM-SUMM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46950</SeqNum>
    <Name>L138.Dravosburg-Wilmerding.Z-77</Name>
    <LastEdit Timestamp="2025-11-18T17:15:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DRAVOSBU" b2="138 KV" b3="DRA-WIL7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="Z-77" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILMERDI" b2="138 KV" b3="Z-77" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46960</SeqNum>
    <Name>L138.Allentown-8th-CenAllen-Sumner-SWhite-Wescos.1</Name>
    <LastEdit Timestamp="2024-11-13T14:55:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="8THST" b2="138 KV" b3="8TH-CEA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="8THST" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="8THST" b2="138 KV" b3="8TH-ALL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="CEAL1INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="CEAL_1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEALALL" b2="138 KV" b3="CEA-SUM1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CEALALL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUMNER" b2="138 KV" b3="SUM-SWH1" />
      <ContingencyEquipment Action="L" Type="LN" b1="S WHI" b2="138 KV" b3="SWH-WES1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="S WHI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUMNER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WESCOSVI" b2="138 KV" b3="ALLE1INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="138 KV" b3="ALLE_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46980</SeqNum>
    <Name>L69.Tredyffrin-NewtownSquare + 230/69.Tredyffrin.8</Name>
    <LastEdit Timestamp="2024-10-28T14:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTOWNS" b2="69 KV" b3="235" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWTOWNS" b2="69 KV" b3="3TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTOWNS" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWTOWNS" b2="69 KV" b3="NEW-TRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TREDYFFR" b2="69 KV" b3="055 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TREDYFFR" b2="230 KV" b3="845 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="TREDYFFR" b2="230 KV" b3="TRED8TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>46990</SeqNum>
    <Name>L115.WestWharton-Franklin.D931</Name>
    <LastEdit Timestamp="2025-12-05T14:16:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLIN" b2="115 KV" b3="B47" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLIN" b2="115 KV" b3="B48" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKLIN" b2="115 KV" b3="FRA-WWHD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="115 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47000</SeqNum>
    <Name>L115.Vernon-Franklin-WestWharton.J932</Name>
    <LastEdit Timestamp="2026-04-08T12:38:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLIN" b2="34.5 KV" b3="B350" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLIN" b2="34.5 KV" b3="B351" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLIN" b2="115 KV" b3="B41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLIN" b2="115 KV" b3="B42" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKLIN" b2="115 KV" b3="FRA-VERJ" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKLIN" b2="115 KV" b3="FRA-WWHJ" />
      <ContingencyEquipment Action="X" Type="XF" b1="FRANKLIN" b2="115 KV" b3="TR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VERNON" b2="115 KV" b3="BK 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="115 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47010</SeqNum>
    <Name>L115.Sayreville-Werner.D30</Name>
    <LastEdit Timestamp="2024-09-20T08:29:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="115 KV" b3="7-8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SAYREVIL" b2="115 KV" b3="BK 7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="115 KV" b3="BK7CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="115 KV" b3="C7" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAYREVIL" b2="115 KV" b3="SAY-WER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WERNER" b2="115 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WERNER" b2="115 KV" b3="B22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47020</SeqNum>
    <Name>L230.Atlantic-OceanView.X2024</Name>
    <LastEdit Timestamp="2026-05-22T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ATLANTIC" b2="230 KV" b3="ATL-OCEX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANVIE" b2="230 KV" b3="B55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANVIE" b2="230 KV" b3="B58" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47030</SeqNum>
    <Name>L230.Atlantic-OceanView.Y2025</Name>
    <LastEdit Timestamp="2025-06-05T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ATLANTIC" b2="230 KV" b3="ATL-OCEY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANVIE" b2="230 KV" b3="B61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANVIE" b2="230 KV" b3="B64" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47040</SeqNum>
    <Name>L230.Bristers-Nokesville-VintHill.2101</Name>
    <LastEdit Timestamp="2025-06-05T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRISTERS" b2="230 KV" b3="2101A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRISTERS" b2="230 KV" b3="L1T2101" />
      <ContingencyEquipment Action="L" Type="LN" b1="NOKESVIL" b2="230 KV" b3="210179" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOKESVIL" b2="230 KV" b3="H132" />
      <ContingencyEquipment Action="X" Type="XF" b1="NOKESVIL" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NOKESVIL" b2="36.5 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINTHILL" b2="230 KV" b3="21012163" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINTHILL" b2="230 KV" b3="21012174" />
      <ContingencyEquipment Action="L" Type="LN" b1="VINTHILL" b2="230 KV" b3="2101A2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VINTHLDP" b2="230 KV" b3="DPLOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47060</SeqNum>
    <Name>L230.Atlantic-RedBank.S1033</Name>
    <LastEdit Timestamp="2026-05-22T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ATLANTIC" b2="230 KV" b3="ATL-REDS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBAJCT" b2="230 KV" b3="S1033 AB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47070</SeqNum>
    <Name>L230.Atlantic-EatonCrest-RedBank.T2020</Name>
    <LastEdit Timestamp="2026-05-22T11:55:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ATLANTIC" b2="230 KV" b3="ATL-EAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B54" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EATONCST" b2="34.5 KV" b3="T3" />
      <ContingencyEquipment Action="X" Type="XF" b1="EATONCST" b2="230 KV" b3="TR3" />
      <ContingencyEquipment Action="L" Type="LN" b1="EATONCST" b2="230 KV" b3="EAT-RED" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBAJCT" b2="230 KV" b3="T2020 AB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47090</SeqNum>
    <Name>L230.Gillette-Greenbrook.W-1037</Name>
    <LastEdit Timestamp="2026-05-29T12:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GILLETTE" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GILLETTE" b2="230 KV" b3="BK 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENBRO" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENBRO" b2="230 KV" b3="1-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="GILLETTE" b2="230 KV" b3="GIL-GREW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENBRO" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENBRO" b2="230 KV" b3="T-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47110</SeqNum>
    <Name>L230.Sayreville-Nejesco-Werner.F1046</Name>
    <LastEdit Timestamp="2026-01-12T12:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEJESCO" b2="230 KV" b3="1 TX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEJESCO" b2="230 KV" b3="2 TX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEJESCO" b2="230 KV" b3="3 TX" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEJESCO" b2="230 KV" b3="NEJ-SAY" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEJESCO" b2="230 KV" b3="NEJ-WER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="F1046EGC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="F1046FAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WERNER" b2="230 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47120</SeqNum>
    <Name>L230.NJTRedBank-RedBankJct</Name>
    <LastEdit Timestamp="2025-07-23T16:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="NJTREDBA" b2="230 KV" b3="NJT-RED" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NJTREDBA" b2="230 KV" b3="UBE TX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NJTREDBA" b2="230 KV" b3="UBW TX" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="REDBAJCT" b2="230 KV" b3="B2028-AC" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="REDBAJCT" b2="230 KV" b3="B2028-BC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47130</SeqNum>
    <Name>L138.BeaverCreek-MorganFork</Name>
    <LastEdit Timestamp="2025-02-03T07:43:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVERCR" b2="138 KV" b3="BEA-MOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANFK" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47140</SeqNum>
    <Name>500/230.Brighton.3</Name>
    <LastEdit Timestamp="2025-08-26T17:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="230 KV" b3="2DB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="230 KV" b3="4DB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="500 KV" b3="7BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIGHTON" b2="500 KV" b3="7CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRIGHTON" b2="500 KV" b3="NO.3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47160</SeqNum>
    <Name>L115.Riverside-NorthPoint-Fitzell.110981</Name>
    <LastEdit Timestamp="2025-04-10T15:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FITZELL" b2="115 KV" b3="110-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FITZELL" b2="34.5 KV" b3="34TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FITZELL" b2="115 KV" b3="981-503" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FITZELL" b2="115 KV" b3="981-504" />
      <ContingencyEquipment Action="L" Type="LN" b1="FITZELL" b2="115 KV" b3="FIT-NOR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FITZELL" b2="34.5 KV" b3="LOAD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="NORTHPT" b2="115 KV" b3="110-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHPT" b2="115 KV" b3="110-1GCB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NORTHPT" b2="34 KV" b3="34060LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHPT" b2="115 KV" b3="NOR-RIV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="115 KV" b3="110981" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47170</SeqNum>
    <Name>L115.Riverside-NorthPoint-Fitzell.110982</Name>
    <LastEdit Timestamp="2025-04-10T15:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FITZELL" b2="115 KV" b3="110-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FITZELL" b2="34.5 KV" b3="34TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FITZELL" b2="115 KV" b3="982-503" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FITZELL" b2="115 KV" b3="982-504" />
      <ContingencyEquipment Action="L" Type="LN" b1="FITZELL" b2="115 KV" b3="FIT-NOR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FITZELL" b2="34.5 KV" b3="LOAD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NORTHPT" b2="115 KV" b3="110-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHPT" b2="115 KV" b3="110-4GCB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NORTHPT" b2="34 KV" b3="34061LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="115 KV" b3="110982" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHPT" b2="115 KV" b3="NOR-RIV2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47180</SeqNum>
    <Name>L115.HighRidge-DorsyTp-CrystlSprngs-DorsyRn.110541</Name>
    <LastEdit Timestamp="2025-04-24T14:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CRYSTLSP" b2="115 KV" b3="110541" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CRYSTLSP" b2="115 KV" b3="TIE ABS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="DORSEYRN" b2="115 KV" b3="1-2ABS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DORSEYRN" b2="115 KV" b3="110_2CSW" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRYSTLSP" b2="115 KV" b3="CRY-DOR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRYSTLSP" b2="115 KV" b3="CRT-DOR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DORSEYTP" b2="115 KV" b3="DOR-MAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="115 KV" b3="230-5LS" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIGHRIDG" b2="230 KV" b3="230-5TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="115 KV" b3="5-115BUS" />
      <ContingencyEquipment Action="L" Type="LN" b1="DORSEYTP" b2="115 KV" b3="DOR-HIG1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MAPESRD" b2="115 KV" b3="539F_541" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47190</SeqNum>
    <Name>L115.HighRidge-DorsyTp-CrystlSprngs-DorsyRn.110542</Name>
    <LastEdit Timestamp="2025-06-24T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CRYSTLSP" b2="115 KV" b3="110542" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRYSTLSP" b2="115 KV" b3="CRY-DOR2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CRYSTLSP" b2="115 KV" b3="TIE ABS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="DORSEYRN" b2="115 KV" b3="1-2ABS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DORSEYRN" b2="115 KV" b3="110542" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRYSTLSP" b2="115 KV" b3="CRT-DOR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DORSEYTP" b2="115 KV" b3="DOR-MAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="115 KV" b3="230-4LS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="115 KV" b3="4-115BUS" />
      <ContingencyEquipment Action="L" Type="LN" b1="DORSEYTP" b2="115 KV" b3="DOR-HIG2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47200</SeqNum>
    <Name>L115.WaughChapel-Crownsville-Cdrpk.110543</Name>
    <LastEdit Timestamp="2025-08-01T15:03:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CEDARPRK" b2="115 KV" b3="110-2CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CEDARPRK" b2="115 KV" b3="110-8CS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="CEDARPRK" b2="34.5 KV" b3="11011102" />
      <ContingencyEquipment Action="CL" Type="CB" b1="CEDARPRK" b2="13.8 KV" b3="11081109" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CEDARPRK" b2="115 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARPRK" b2="115 KV" b3="CED-CRO3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CROWNSVI" b2="115 KV" b3="543_544" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="110543SF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="548_543" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROWNSVI" b2="115 KV" b3="CRO-WAU3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47210</SeqNum>
    <Name>L115.WaughChapel-Crownsville-Cedar-Bestgate.110544</Name>
    <LastEdit Timestamp="2026-05-26T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="BESTGATE" b2="13.8 KV" b3="11011102" />
      <ContingencyEquipment Action="CL" Type="CB" b1="BESTGATE" b2="13.8 KV" b3="11021103" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BESTGATE" b2="115 KV" b3="110544_1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BESTGATE" b2="115 KV" b3="110544_2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BESTGATE" b2="115 KV" b3="110544_3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BESTGATE" b2="115 KV" b3="BES-BES4" />
      <ContingencyEquipment Action="L" Type="LN" b1="BESTGTAP" b2="115 KV" b3="BES-CRO4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CEDARPRK" b2="115 KV" b3="110-1 HS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CEDARPRK" b2="13.8 KV" b3="110-9 DS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CEDARPRK" b2="115 KV" b3="110-9CS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="CEDARPRK" b2="34.5 KV" b3="11011102" />
      <ContingencyEquipment Action="CL" Type="CB" b1="CEDARPRK" b2="13.8 KV" b3="11081109" />
      <ContingencyEquipment Action="L" Type="LN" b1="BESTGTAP" b2="115 KV" b3="BES-CED4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CEDARPRK" b2="115 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CROWNSVI" b2="115 KV" b3="110544" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CROWNSVI" b2="115 KV" b3="543_544" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROWNSVI" b2="115 KV" b3="CRO-WAU4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="110544SF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="544_546" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47220</SeqNum>
    <Name>230/115.HighRidge.230-5</Name>
    <LastEdit Timestamp="2025-04-08T10:20:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="CRYSTLSP" b2="115 KV" b3="TIE ABS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="DORSEYRN" b2="115 KV" b3="1-2ABS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="230-5CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="115 KV" b3="230-5LS" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIGHRIDG" b2="230 KV" b3="230-5TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="23052332" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47230</SeqNum>
    <Name>230/115.HighRidge.230-4</Name>
    <LastEdit Timestamp="2025-06-05T12:40:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="CRYSTLSP" b2="115 KV" b3="TIE ABS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="DORSEYRN" b2="115 KV" b3="1-2ABS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="DORSEYRN" b2="115 KV" b3="1-2TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="230-4CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="115 KV" b3="230-4LS" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIGHRIDG" b2="230 KV" b3="230-4TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="23142304" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47240</SeqNum>
    <Name>L115.Northwest-ColPipe-DeerPark.110571</Name>
    <LastEdit Timestamp="2025-11-10T14:05:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COL_PIPE" b2="115 KV" b3="COL_PIPE" />
      <ContingencyEquipment Action="L" Type="LN" b1="COL_PIPE" b2="115 KV" b3="COL-DEER" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEERPARK" b2="115 KV" b3="DEE-WES" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEERPARK" b2="115 KV" b3="DEE-WHI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWES" b2="115 KV" b3="110571CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="COL_PIPE" b2="115 KV" b3="COL-NORW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WESMSTER" b2="115 KV" b3="110-1 HS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="WESMSTER" b2="34.5 KV" b3="11011102" />
      <ContingencyEquipment Action="CL" Type="CB" b1="WESMSTER" b2="13.8 KV" b3="11031104" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WESMSTER" b2="115 KV" b3="115TIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WESMSTER" b2="115 KV" b3="DUM110-3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WHITEROC" b2="115 KV" b3="110-3CSW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WHITEROC" b2="115 KV" b3="115TIE" />
      <ContingencyEquipment Action="CL" Type="CB" b1="WHITEROC" b2="34.5 KV" b3="LSTIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47250</SeqNum>
    <Name>L115.Northwest-Finksburg-Westminster.110572</Name>
    <LastEdit Timestamp="2025-01-21T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FINKSBUR" b2="115 KV" b3="110-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINKSBUR" b2="115 KV" b3="110-1HS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FINKSBUR" b2="115 KV" b3="110TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHWES" b2="115 KV" b3="FIN-NOR" />
      <ContingencyEquipment Action="L" Type="LN" b1="FINKSBUR" b2="115 KV" b3="FIN-WES2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWES" b2="115 KV" b3="110572CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WESMSTER" b2="115 KV" b3="110-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="WESMSTER" b2="115 KV" b3="110-4" />
      <ContingencyEquipment Action="CL" Type="CB" b1="WESMSTER" b2="34.5 KV" b3="11011102" />
      <ContingencyEquipment Action="CL" Type="CB" b1="WESMSTER" b2="13.8 KV" b3="11031104" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WESMSTER" b2="115 KV" b3="115TIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47260</SeqNum>
    <Name>L138.Allentown-EAllentwn-C-Northampton-Siegfried.1</Name>
    <LastEdit Timestamp="2024-11-14T16:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENTOW" b2="138 KV" b3="ALL-EAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="SIEG1INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="SIEG_1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLENTOW" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATT" b2="138 KV" b3="ATT-EAL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATT" b2="138 KV" b3="ATT-EAL3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="ATT" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ATT" b2="138 KV" b3="TIE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CATA TP" b2="138 KV" b3="CAT-EAL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CATA TP" b2="138 KV" b3="CAT-NOR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CATA TP" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="E ALLENT" b2="138 KV" b3="ATT1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="E ALLENT" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="NAMPTON" b2="138 KV" b3="NHA-SIE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NAMPTON" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAMPTON" b2="138 KV" b3="TAP_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="138 KV" b3="ALLE1INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="138 KV" b3="ALLE_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47270</SeqNum>
    <Name>L138.Allentown-EAllentwn-C-Northampton-Siegfried.2</Name>
    <LastEdit Timestamp="2024-11-14T16:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENTOW" b2="138 KV" b3="ALL-EAL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="SIEG2INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="SIEG_2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATT" b2="138 KV" b3="ATT-EAL2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATT" b2="138 KV" b3="ATT-EAL4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="ATT" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ATT" b2="138 KV" b3="TIE2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CATA TP" b2="138 KV" b3="CAT-EAL2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CATA TP" b2="138 KV" b3="CAT-NOR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CATA TP" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="E ALLENT" b2="138 KV" b3="ATT2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="E ALLENT" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="NAMPTON" b2="138 KV" b3="NHA-SIE2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NAMPTON" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAMPTON" b2="138 KV" b3="TAP_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="138 KV" b3="ALLE2INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="138 KV" b3="ALLE_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47300</SeqNum>
    <Name>L138.Siegfried-Egypt-S-C-Dornyville-Wescosville.1</Name>
    <LastEdit Timestamp="2024-11-13T13:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRCKRPRT" b2="138 KV" b3="CRC-SCH1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRCKRPRT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRCKRPRT" b2="138 KV" b3="CRC-DOR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DORNYVLE" b2="138 KV" b3="DOR-WES1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DORNYVLE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EGYPT" b2="138 KV" b3="EGY-SCH1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EGYPT" b2="138 KV" b3="EGY-SIE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EGYPT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCHNCKVL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="138 KV" b3="WESC1INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="138 KV" b3="WESC_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="138 KV" b3="SIEG1INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="138 KV" b3="SIEG_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47310</SeqNum>
    <Name>L115.Northwest-PHil-Dlfd-Hrnv-Granite.110560</Name>
    <LastEdit Timestamp="2025-12-24T11:38:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="DOLFIELD" b2="115 KV" b3="1-2ABS" />
      <ContingencyEquipment Action="S" Type="SD" b1="DOLFIELD" b2="115 KV" b3="110560" />
      <ContingencyEquipment Action="CL" Type="CB" b1="DOLFIELD" b2="115 KV" b3="115KVTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOLFIELD" b2="115 KV" b3="DOL-HAR0" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOLFIELD" b2="115 KV" b3="DOL-PLE0" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DOLFIELD" b2="115 KV" b3="DUM14779" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="115 KV" b3="110560-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="115 KV" b3="530_60A" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANITE" b2="115 KV" b3="GRA-HAR0" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR BC" b2="115 KV" b3="2TR-560A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARR BC" b2="115 KV" b3="3TR_560A" />
      <ContingencyEquipment Action="CL" Type="CB" b1="HARR BC" b2="115 KV" b3="3TR_561" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="110560" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="574-560" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PLESNTHL" b2="115 KV" b3="1102_560" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PLESNTHL" b2="115 KV" b3="1104TIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PLESNTHL" b2="115 KV" b3="1104_560" />
      <ContingencyEquipment Action="S" Type="SD" b1="PLESNTHL" b2="115 KV" b3="110560SD" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PLESNTHL" b2="115 KV" b3="1_2TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="NRTHWES2" b2="115 KV" b3="NOR-PLE2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="WHITEROC" b2="115 KV" b3="115TIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47320</SeqNum>
    <Name>L138.Siegfried-Egypt-S-C-Dornyville-Wescosville.2</Name>
    <LastEdit Timestamp="2024-11-13T13:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRCKRPRT" b2="138 KV" b3="CRC-SCH2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRCKRPRT" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRCKRPRT" b2="138 KV" b3="CRC-DOR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DORNYVLE" b2="138 KV" b3="DOR-WES2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DORNYVLE" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EGYPT" b2="138 KV" b3="EGY-SCH2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EGYPT" b2="138 KV" b3="EGY-SIE2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EGYPT" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCHNCKVL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="138 KV" b3="WESC2INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="138 KV" b3="WESC_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="138 KV" b3="SIEG2INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="138 KV" b3="SIEG_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47330</SeqNum>
    <Name>L138.Darlington-SouthMawa.588</Name>
    <LastEdit Timestamp="2024-10-30T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARLNGTO" b2="138 KV" b3="588-43-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARLNGTO" b2="138 KV" b3="DAR-SMA8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="588-582Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="T51-588" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47340</SeqNum>
    <Name>L138.SouthMahwah-MacarthurBlvd.589</Name>
    <LastEdit Timestamp="2026-05-26T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MACARTHR" b2="138 KV" b3="589-70-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MACARTHR" b2="138 KV" b3="MAC-SMA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="589-582X" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="T589-758" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47350</SeqNum>
    <Name>L138.Darlington-MacarthurBlvd.590</Name>
    <LastEdit Timestamp="2026-05-26T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARLNGTO" b2="138 KV" b3="590-43-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MACARTHR" b2="138 KV" b3="DAR-MAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACARTHR" b2="138 KV" b3="590-70-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47360</SeqNum>
    <Name>L138.Allendale-SouthMahwah.585</Name>
    <LastEdit Timestamp="2025-02-27T13:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENDAL" b2="138 KV" b3="ALL-SMA5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENDAL" b2="138 KV" b3="T139-2Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENDAL" b2="138 KV" b3="T239-2Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="585-582Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="T658-585" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47370</SeqNum>
    <Name>L115.Northwest-P.Hill-Dlfld-Hrsnvl-Granite.110561</Name>
    <LastEdit Timestamp="2025-12-24T11:43:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="DOLFIELD" b2="115 KV" b3="110561" />
      <ContingencyEquipment Action="CL" Type="CB" b1="DOLFIELD" b2="115 KV" b3="115KVTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOLFIELD" b2="115 KV" b3="561_561B" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOLFIELD" b2="115 KV" b3="DOL-HAR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOLFIELD" b2="115 KV" b3="DOL-PLE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="115 KV" b3="110561-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="115 KV" b3="561A_529" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANITE" b2="115 KV" b3="GRA-HAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR BC" b2="115 KV" b3="1TR_561" />
      <ContingencyEquipment Action="CL" Type="CB" b1="HARR BC" b2="115 KV" b3="2TR-560A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR BC" b2="115 KV" b3="3TR_561" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="110561" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="579-561" />
      <ContingencyEquipment Action="L" Type="LN" b1="NRTHWES2" b2="115 KV" b3="NOR-PLE1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PLESNTHL" b2="115 KV" b3="1101_561" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PLESNTHL" b2="115 KV" b3="1104TIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PLESNTHL" b2="115 KV" b3="1104_561" />
      <ContingencyEquipment Action="S" Type="SD" b1="PLESNTHL" b2="115 KV" b3="110561SD" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PLESNTHL" b2="115 KV" b3="1_2TIE" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="WHITEROC" b2="115 KV" b3="115TIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47380</SeqNum>
    <Name>L138.Allendale-SouthMawa.587</Name>
    <LastEdit Timestamp="2025-06-24T08:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENDAL" b2="138 KV" b3="ALL-SMA7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENDAL" b2="138 KV" b3="T587-139" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENDAL" b2="138 KV" b3="T588-239" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="587-582Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="T258-587" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47390</SeqNum>
    <Name>L115.Perryman-Edgewood-Joppatown.110620</Name>
    <LastEdit Timestamp="2025-06-24T08:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="EDGEWOO1" b2="115 KV" b3="45TIEABS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EDGEWOO1" b2="115 KV" b3="620_5TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEWOO1" b2="115 KV" b3="EDG-JOP0" />
      <ContingencyEquipment Action="L" Type="LN" b1="PERRYMAN" b2="115 KV" b3="EDG-PER0" />
      <ContingencyEquipment Action="CL" Type="CB" b1="JOPPATOW" b2="13.8 KV" b3="11011102" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="JOPPATOW" b2="115 KV" b3="110620-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOPPATOW" b2="115 KV" b3="620-621" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOPPATOW" b2="115 KV" b3="620-624" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="JOPPATOW" b2="115 KV" b3="620A_2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="110620" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="616_620" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47400</SeqNum>
    <Name>L115.Perryman-Edgewood-Joppatown.110621</Name>
    <LastEdit Timestamp="2026-05-29T12:44:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEWOO1" b2="115 KV" b3="110-4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDGEWOO1" b2="34.5 KV" b3="110-4 LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEWOO1" b2="115 KV" b3="EDG-JOP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PERRYMAN" b2="115 KV" b3="EDG-PER1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="JOPPATOW" b2="115 KV" b3="110620-A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="JOPPATOW" b2="115 KV" b3="110621-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOPPATOW" b2="115 KV" b3="620-621" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOPPATOW" b2="115 KV" b3="621-624" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="JOPPATOW" b2="115 KV" b3="621A_2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="110621" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="615_621" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47410</SeqNum>
    <Name>L138.Cheswick-California-North.Z-66</Name>
    <LastEdit Timestamp="2026-05-28T09:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CALIFDUQ" b2="138 KV" b3="CAL-NOR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESWICK" b2="138 KV" b3="CHE-CAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CALIFDUQ" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWICK" b2="138 KV" b3="CALIFT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTH" b2="138 KV" b3="CAL_Z66" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47430</SeqNum>
    <Name>L138.Crescent-Hopewell.Z-25</Name>
    <LastEdit Timestamp="2024-12-18T15:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRES DUQ" b2="138 KV" b3="CRE-HOP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="138 KV" b3="HOPEZ-25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWELL" b2="138 KV" b3="CRES25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47440</SeqNum>
    <Name>L138.Hopewell-Koppel-Legion.Z-27</Name>
    <LastEdit Timestamp="2025-01-16T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HOPEWELL" b2="138 KV" b3="HOP-KOP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWELL" b2="138 KV" b3="KOPPL27" />
      <ContingencyEquipment Action="L" Type="LN" b1="KOPPELST" b2="138 KV" b3="KOP-LEG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KOPPELST" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGIONVI" b2="138 KV" b3="KOPPL27" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47450</SeqNum>
    <Name>L138.Valley-WolfeRun-Legionville.Z-84</Name>
    <LastEdit Timestamp="2025-06-26T11:45:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LEGIONVI" b2="138 KV" b3="LEG-WOL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGIONVI" b2="138 KV" b3="VALLEY" />
      <ContingencyEquipment Action="L" Type="LN" b1="VALL DUQ" b2="138 KV" b3="VAL-WOL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="138 KV" b3="Z-84" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOLFERUN" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47460</SeqNum>
    <Name>L138.Auburn-AuburnC5-GarrettNorth</Name>
    <LastEdit Timestamp="2024-10-30T15:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AUBURN" b2="138 KV" b3="AUB-AUB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUBURN" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="L" Type="LN" b1="AUBURNC5" b2="138 KV" b3="AUB-GAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AUBURNC5" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARRETTN" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47480</SeqNum>
    <Name>L138.Broadford-Keywood-WolfHill</Name>
    <LastEdit Timestamp="2025-08-13T13:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROADFO2" b2="138 KV" b3="BRO-KEY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="138 KV" b3="G2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEYWOOD" b2="138 KV" b3="VA GAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFHILL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEYWOOD" b2="138 KV" b3="KEY-WOL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47490</SeqNum>
    <Name>L138.Trent-Centerburg</Name>
    <LastEdit Timestamp="2026-05-26T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTERBU" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTERBU" b2="138 KV" b3="CEN-TRE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CENTERBU" b2="138 KV" b3="CENTERBU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENT" b2="138 KV" b3="102N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47500</SeqNum>
    <Name>L138.Britton-Dublin</Name>
    <LastEdit Timestamp="2025-09-04T14:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRITTON" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRITTON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRITTON" b2="138 KV" b3="BRI-DUB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUBLIN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUBLIN" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47510</SeqNum>
    <Name>L138.Sawmill-Dublin</Name>
    <LastEdit Timestamp="2025-09-04T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUBLIN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUBLIN" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="103C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="103S" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAWMILL" b2="138 KV" b3="SAW-DUB1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47520</SeqNum>
    <Name>L138.HyattCS-Greif</Name>
    <LastEdit Timestamp="2024-12-05T16:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREIF" b2="138 KV" b3="C CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREIF" b2="138 KV" b3="D CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREIF" b2="138 KV" b3="GRE-HYA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="105C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="AF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47530</SeqNum>
    <Name>L138.Huntley-ScherersSw-Greif</Name>
    <LastEdit Timestamp="2024-11-06T12:54:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREIF" b2="138 KV" b3="A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREIF" b2="138 KV" b3="B CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREIF" b2="138 KV" b3="GRE-SCHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTLEY2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTLEY2" b2="138 KV" b3="HUN-SCHE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCHERERS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47540</SeqNum>
    <Name>L138.NewCastle-CityofNewCastle-HaresCorner.13811</Name>
    <LastEdit Timestamp="2026-05-26T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CITYNEWC" b2="138 KV" b3="130 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CITYNEWC" b2="138 KV" b3="CIT-HAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CITYNEWC" b2="138 KV" b3="CIT-NEW" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CITYNEWC" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARESCOR" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARESCOR" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="138 KV" b3="133" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47550</SeqNum>
    <Name>L138.IndianRiver-Robinsonville.13705</Name>
    <LastEdit Timestamp="2026-05-26T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="8060" />
      <ContingencyEquipment Action="L" Type="LN" b1="INDIANRI" b2="138 KV" b3="IND-ROB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBINS" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBINS" b2="138 KV" b3="133" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47560</SeqNum>
    <Name>L138.Keeney-SunsetLake.13817</Name>
    <LastEdit Timestamp="2026-01-23T09:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="136CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="137" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEENEY" b2="138 KV" b3="KEE-SUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNSETLA" b2="138 KV" b3="130 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNSETLA" b2="138 KV" b3="131 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47570</SeqNum>
    <Name>L138.Kiamensi-Silverbrook.13829</Name>
    <LastEdit Timestamp="2026-05-26T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="L" Type="LN" b1="KIAMENSI" b2="138 KV" b3="KIA-SIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERBR" b2="138 KV" b3="135" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47580</SeqNum>
    <Name>L138.OceanBay-138thStreet.13731</Name>
    <LastEdit Timestamp="2026-05-26T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANBAY" b2="138 KV" b3="170" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANBAY" b2="138 KV" b3="174" />
      <ContingencyEquipment Action="L" Type="LN" b1="OCEANBAY" b2="138 KV" b3="OCB-ST1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ST138" b2="138 KV" b3="132" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47590</SeqNum>
    <Name>L138.34Kingsbury-58Grand.5801</Name>
    <LastEdit Timestamp="2025-06-24T13:08:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="34 KINGS" b2="138 KV" b3="5801 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="34 KINGS" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT6-7 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47600</SeqNum>
    <Name>L138.Kingsbury-Grand.5802</Name>
    <LastEdit Timestamp="2025-02-27T14:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="34 KINGS" b2="138 KV" b3="5802 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="34 KINGS" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT2-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47610</SeqNum>
    <Name>L138.58Grand-65Ohio.5808</Name>
    <LastEdit Timestamp="2025-07-15T13:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="65 OHIO" b2="138 KV" b3="5808 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1314CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1415CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="65 OHIO" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47620</SeqNum>
    <Name>L138.58Grand-65Ohio.5807</Name>
    <LastEdit Timestamp="2025-07-15T13:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="65 OHIO" b2="138 KV" b3="5807 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1718CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1819CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="65 OHIO" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47630</SeqNum>
    <Name>L138.Lick-EBeaver</Name>
    <LastEdit Timestamp="2025-11-07T15:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEAVER" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="EBEAVER" b2="138 KV" b3="EBE-LIC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEAVER" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICK" b2="138 KV" b3="106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICK" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47640</SeqNum>
    <Name>L138.54Clybourn-82Crosby.8210</Name>
    <LastEdit Timestamp="2025-06-24T13:08:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="54 CLYBO" b2="138 KV" b3="8210" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="54 CLYBO" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1018CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1718CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT5-18CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47650</SeqNum>
    <Name>L138.785Ontario-82Crosby.8211</Name>
    <LastEdit Timestamp="2025-06-24T08:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="785 ONTA" b2="138 KV" b3="8211" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="785 ONTA" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT3-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47660</SeqNum>
    <Name>L138.785_Ontario-82_Crosby.8214</Name>
    <LastEdit Timestamp="2026-05-26T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="785 ONTA" b2="138 KV" b3="8214" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="785 ONTA" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1112CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47690</SeqNum>
    <Name>L345.Kirk-WestMillers</Name>
    <LastEdit Timestamp="2025-02-07T12:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="345 KV" b3="E CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="345 KV" b3="E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="WMILLERS" b2="345 KV" b3="WMI-KIR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="345 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="345 KV" b3="L2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47700</SeqNum>
    <Name>L138.Kankakee-WestSide</Name>
    <LastEdit Timestamp="2025-05-28T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KANKAKEE" b2="138 KV" b3="KAN-WSI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANKAKEE" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSIDE" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47710</SeqNum>
    <Name>L345.Dequine-Fowler + Fowler.WF</Name>
    <LastEdit Timestamp="2025-03-24T14:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEQUINE" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEQUINE" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEQUINE" b2="345 KV" b3="DEQ-FOWJ" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FOWLER" b2="34.5 KV" b3="1CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FOWLER" b2="34.5 KV" b3="1CAP2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FOWLER" b2="34.5 KV" b3="1CAP3" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOWLERJC" b2="345 KV" b3="FOW-FOW1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOWLERJC" b2="345 KV" b3="FOW-FOW2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOWLER" b2="345 KV" b3="FOW-FOW3" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOWLER" b2="345 KV" b3="FOW-FOW4" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOWLER" b2="345 KV" b3="FOW-FOW5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOWLER" b2="34.5 KV" b3="FWL2-1WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOWLER" b2="34.5 KV" b3="FWL2-2WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOWLER" b2="34.5 KV" b3="FWL2-3WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOWLER" b2="34.5 KV" b3="FWL2-4WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOWLER" b2="34.5 KV" b3="FWLR1AWF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOWLER" b2="34.5 KV" b3="FWLR1BWF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOWLER" b2="34.5 KV" b3="FWLR3WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FOWLER" b2="34.5 KV" b3="FWLR4WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FWLRMISO" b2="34.5 KV" b3="FWL2-4WF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47720</SeqNum>
    <Name>L345.Dequine-MeadowLake.1</Name>
    <LastEdit Timestamp="2025-08-25T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEQUINE" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEQUINE" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEQUINE" b2="345 KV" b3="DEQ-MEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWLK" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWLK" b2="345 KV" b3="D1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47760</SeqNum>
    <Name>L345.Athens-Leeds (SENY)</Name>
    <LastEdit Timestamp="2026-05-26T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ATHENS" b2="345 KV" b3="ATH-LEE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENS" b2="345 KV" b3="R9561" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENS" b2="345 KV" b3="R9562" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEEDS" b2="345 KV" b3="R395" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEEDS" b2="345 KV" b3="R95" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47780</SeqNum>
    <Name>L345.Bowline-Ladentown (SENY)</Name>
    <LastEdit Timestamp="2026-05-26T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWLINE" b2="345 KV" b3="255-55-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWLINE" b2="345 KV" b3="67-55-3Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWLINE" b2="345 KV" b3="68-55-2Z" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOWLINE" b2="345 KV" b3="BOW-LAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADENTOW" b2="345 KV" b3="4-56-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADENTOW" b2="345 KV" b3="6-56-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47790</SeqNum>
    <Name>L345.Bowline-W.Haverstraw-Ladentown (SENY)</Name>
    <LastEdit Timestamp="2026-05-26T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWLINE" b2="345 KV" b3="67-55-3Y" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOWLINE" b2="345 KV" b3="BOW-WHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWLINE" b2="345 KV" b3="T155-67" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADENTOW" b2="345 KV" b3="1-56-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADENTOW" b2="345 KV" b3="3-56-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LADENTOW" b2="345 KV" b3="LAD-WHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHAVERST" b2="138 KV" b3="194E-27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHAVERST" b2="138 KV" b3="194W-541" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHAVERST" b2="345 KV" b3="BK194" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47800</SeqNum>
    <Name>L345.Freshkills-Goethals.21 (SENY)</Name>
    <LastEdit Timestamp="2025-06-13T07:32:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRESHKIL" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRESHKIL" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRESHKIL" b2="345 KV" b3="FRE-GOE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="6X" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47810</SeqNum>
    <Name>L345.Freshkills-Goethals.22</Name>
    <LastEdit Timestamp="2025-02-27T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRESHKIL" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRESHKIL" b2="345 KV" b3="6" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRESHKIL" b2="345 KV" b3="FRE-GOE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="4X" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47820</SeqNum>
    <Name>L345.Goethals-Gowanus.25</Name>
    <LastEdit Timestamp="2024-11-13T13:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="5" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOETHALS" b2="345 KV" b3="GOE-GOW" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GOETHALS" b2="345 KV" b3="R25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOWANUS" b2="345 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOWANUS" b2="345 KV" b3="6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>47830</SeqNum>
    <Name>L345.Goethals-Gowanus.26</Name>
    <LastEdit Timestamp="2024-11-13T13:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="9" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOETHALS" b2="345 KV" b3="GOE-GOW6" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GOETHALS" b2="345 KV" b3="R26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOWANUS" b2="345 KV" b3="16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOWANUS" b2="345 KV" b3="18" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48000</SeqNum>
    <Name>230/69.Grays Ferry.TR9 + L69.Grays Ferry-Schuykill</Name>
    <LastEdit Timestamp="2026-05-26T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="295 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="395 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRAYSFER" b2="230 KV" b3="9TRAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYSFER" b2="69 KV" b3="GRA-SCH9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="330 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="905 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48010</SeqNum>
    <Name>138/69.Church.AT2</Name>
    <LastEdit Timestamp="2026-05-22T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="7210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="138 KV" b3="8420" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHURCH" b2="138 KV" b3="AT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48020</SeqNum>
    <Name>L230.Eldred-Sunbury+230/69.Eldred.TR1</Name>
    <LastEdit Timestamp="2024-11-21T09:07:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ELDRED" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELDRED" b2="230 KV" b3="ELD-SUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDRED" b2="230 KV" b3="SUNBLINE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDRED" b2="69 KV" b3="TRAN_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="ELDR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="ELDRMIL2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48030</SeqNum>
    <Name>L138.SouthAkron-Leola-Drt-Brl-ELanCst-Prince.1</Name>
    <LastEdit Timestamp="2024-11-15T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BURLE" b2="138 KV" b3="BUR-DON1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURLE" b2="138 KV" b3="BUR-ELA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BURLE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BURLE" b2="138 KV" b3="TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARTCONT" b2="138 KV" b3="DAR-LEO1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DARTCONT" b2="138 KV" b3="TAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DONNGRAV" b2="138 KV" b3="DON-NBR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DONNGRAV" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DONNGRAV" b2="138 KV" b3="TAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELANCAST" b2="138 KV" b3="ELA-PRI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELANCAST" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEOLA" b2="138 KV" b3="LEO-SAK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEOLA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARTCONT" b2="138 KV" b3="DAR-NBR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NBRIDGEP" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PRINCEPL" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PRINCEPL" b2="138 KV" b3="TIE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="138 KV" b3="P1-D1TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="138 KV" b3="PRIN_1-W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48040</SeqNum>
    <Name>L138.SouthAkron-Leola-Drt-Brl-ELancst-Prince.2</Name>
    <LastEdit Timestamp="2024-11-18T13:26:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BURLE" b2="138 KV" b3="BUR-DON2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURLE" b2="138 KV" b3="BUR-ELA2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BURLE" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BURLE" b2="138 KV" b3="TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARTCONT" b2="138 KV" b3="DAR-NBR2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DARTCONT" b2="138 KV" b3="TAP2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DONNGRAV" b2="138 KV" b3="TAP2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELANCAST" b2="138 KV" b3="ELA-PRI2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELANCAST" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARTCONT" b2="138 KV" b3="DAR-LEO2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEOLA" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DONNGRAV" b2="138 KV" b3="DON-NBR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NBRIDGEP" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PRINCEPL" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PRINCEPL" b2="138 KV" b3="TIE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEOLA" b2="138 KV" b3="LEO-SAK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="138 KV" b3="P2-D2TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="138 KV" b3="PRIN_2-W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48050</SeqNum>
    <Name>L230.Gloucester-CamdenGen.J-2262</Name>
    <LastEdit Timestamp="2025-06-16T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDENGN" b2="230 KV" b3="52-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMDENGN" b2="230 KV" b3="CAM-GLO" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CAMDENGN" b2="13 KV" b3="CMDN#1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CAMDENGN" b2="13 KV" b3="CMDN#2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="J2262L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48070</SeqNum>
    <Name>L230.ToscoCB-ToscoGIS.1</Name>
    <LastEdit Timestamp="2024-12-24T13:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOCB" b2="230 KV" b3="CB1" />
      <ContingencyEquipment Action="S" Type="SD" b1="TOSCOCB" b2="230 KV" b3="RX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TOSCOCB" b2="230 KV" b3="TOS-TOS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOGIS" b2="230 KV" b3="230-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOGIS" b2="230 KV" b3="230-9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48080</SeqNum>
    <Name>L230.ToscoCB-ToscoGIS.2</Name>
    <LastEdit Timestamp="2024-12-24T13:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOCB" b2="230 KV" b3="CB2" />
      <ContingencyEquipment Action="S" Type="SD" b1="TOSCOCB" b2="230 KV" b3="RX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TOSCOCB" b2="230 KV" b3="TOS-TOS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOGIS" b2="230 KV" b3="230-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOGIS" b2="230 KV" b3="230-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48090</SeqNum>
    <Name>L138.WHempfield-Donnerville-LAP-Roh-Don-Prince.1</Name>
    <LastEdit Timestamp="2025-04-23T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DONNELLE" b2="138 KV" b3="DON-DIL1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DILLERVI" b2="138 KV" b3="DONNEL1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DONNELLE" b2="138 KV" b3="TAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DONNERVL" b2="138 KV" b3="DON-LAN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DONNERVL" b2="138 KV" b3="DON-WHE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DONNERVL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LANCAIRP" b2="138 KV" b3="LAPRTAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DONNELLE" b2="138 KV" b3="DON-PRI1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PRINCEPL" b2="138 KV" b3="DONNELL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DONNELLE" b2="138 KV" b3="DON-ROH1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANCAIRP" b2="138 KV" b3="LAN-ROH1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROHRSTOW" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="138 KV" b3="PRIN_1-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="138 KV" b3="PRIN_1-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48100</SeqNum>
    <Name>L138.WHempfield-Donnerville-LAP-Roh-Don-Prince.2</Name>
    <LastEdit Timestamp="2025-04-18T17:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="DILLERVI" b2="138 KV" b3="DONNEL2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DONNELLE" b2="138 KV" b3="DON-DIL2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DONNELLE" b2="138 KV" b3="DON-PRI2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DONNELLE" b2="138 KV" b3="DON-ROH2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DONNELLE" b2="138 KV" b3="TAP2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DONNERVL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DONNERVL" b2="138 KV" b3="DON-LAN2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANCAIRP" b2="138 KV" b3="LAN-ROH2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LANCAIRP" b2="138 KV" b3="LAPRTAP2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PRINCEPL" b2="138 KV" b3="DONNELL2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROHRSTOW" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DONNERVL" b2="138 KV" b3="DON-WHE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="138 KV" b3="PRIN_2-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="138 KV" b3="PRIN_2-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48110</SeqNum>
    <Name>L230.EagleGen-EaglePt.1</Name>
    <LastEdit Timestamp="2026-02-10T13:13:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLEGEN" b2="230 KV" b3="103" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EAGLEGEN" b2="13 KV" b3="EGLE#1" />
      <ContingencyEquipment Action="X" Type="XF" b1="EAGLEGEN" b2="230 KV" b3="NO1 GSU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EAGLEGEN" b2="13 KV" b3="XFMR6LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLEPT" b2="230 KV" b3="101" />
      <ContingencyEquipment Action="L" Type="LN" b1="EAGLEGEN" b2="230 KV" b3="EAG-EAG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48120</SeqNum>
    <Name>L230.EagleGen-EaglePoint.2</Name>
    <LastEdit Timestamp="2026-02-10T13:14:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLEGEN" b2="230 KV" b3="104" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EAGLEGEN" b2="13 KV" b3="EGLE#2" />
      <ContingencyEquipment Action="X" Type="XF" b1="EAGLEGEN" b2="230 KV" b3="NO3 GSU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EAGLEGEN" b2="13 KV" b3="XFMR7LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLEPT" b2="230 KV" b3="102" />
      <ContingencyEquipment Action="L" Type="LN" b1="EAGLEGEN" b2="230 KV" b3="EAG-EAG2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48140</SeqNum>
    <Name>230.LindenVFT-VFT_St</Name>
    <LastEdit Timestamp="2024-11-20T15:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINVFT" b2="17 KV" b3="411" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINVFT" b2="17 KV" b3="412" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINVFT" b2="17 KV" b3="413" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINVFT" b2="17 KV" b3="421" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINVFT" b2="17 KV" b3="422" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINVFT" b2="17 KV" b3="423" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINVFT" b2="345 KV" b3="CB5_1S" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOGEN" b2="345 KV" b3="LIN-LIN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINVFT" b2="17 KV" b3="NY-VFT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINVFT" b2="17 KV" b3="NY-VFT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINVFT" b2="17 KV" b3="NY-VFT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINVFT" b2="17 KV" b3="PJM-VFT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINVFT" b2="17 KV" b3="PJM-VFT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINVFT" b2="17 KV" b3="PJM-VFT3" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINVFT" b2="230 KV" b3="XF21R1" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINVFT" b2="230 KV" b3="XF21R2" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINVFT" b2="230 KV" b3="XF21R3" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINVFT" b2="345 KV" b3="XF21S1" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINVFT" b2="345 KV" b3="XF21S2" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINVFT" b2="345 KV" b3="XF21S3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VFT_ST" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VFT_ST" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINVFT" b2="230 KV" b3="LIN-VFT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48150</SeqNum>
    <Name>L230.Lawrence-LawrenceSw.G-2233</Name>
    <LastEdit Timestamp="2024-12-23T11:58:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="2-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="7-8CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAWRENCE" b2="230 KV" b3="LAW-LAWG" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LAWRESUB" b2="230 KV" b3="T1020TRS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LAWRESUB" b2="230 KV" b3="T3040TRS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAWRESUB" b2="230 KV" b3="TRANT-20" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAWRESUB" b2="230 KV" b3="TRANT-40" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48160</SeqNum>
    <Name>L230.BennettsLane-Adams-Brunswick.V-2248</Name>
    <LastEdit Timestamp="2024-12-03T14:06:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ADAMS" b2="230 KV" b3="ADA-BENX" />
      <ContingencyEquipment Action="L" Type="LN" b1="ADAMS" b2="230 KV" b3="ADA-BRUX" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="ADAMS" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ADAMS" b2="230 KV" b3="TRAN T-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNETTS" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNETTS" b2="230 KV" b3="220-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SECT 2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SECT 5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48240</SeqNum>
    <Name>L345.Loretto-WiltonCenter.11212</Name>
    <LastEdit Timestamp="2026-05-26T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="93 LORET" b2="345 KV" b3="11212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="112 WILT" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="93 LORET" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="93 LORET" b2="345 KV" b3="BT2-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48250</SeqNum>
    <Name>L345.Loretto-Pontiac.8012</Name>
    <LastEdit Timestamp="2026-05-26T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="80 PONTI" b2="345 KV" b3="8012 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="80 PONTI" b2="345 KV" b3="BT4-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="80 PONTI" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="93 LORET" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="93 LORET" b2="345 KV" b3="BT1-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48260</SeqNum>
    <Name>345/138.SugarCreek.BK-S (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-29T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUGARCRE" b2="345 KV" b3="BH-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUGARCRE" b2="345 KV" b3="BK-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="138 KV" b3="RS-G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="138 KV" b3="RS-K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="138 KV" b3="RS-M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48270</SeqNum>
    <Name>345/138.SugarCreek.BK-N (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-26T14:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUGARCRE" b2="345 KV" b3="BH-N" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUGARCRE" b2="345 KV" b3="BK-N" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUGARCRE" b2="138 KV" b3="BL-N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48280</SeqNum>
    <Name>138/69.Alpha.BK7 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-26T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="09ALPHA" b2="138 KV" b3="BH7" />
      <ContingencyEquipment Action="X" Type="XF" b1="09ALPHA" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="09ALPHA" b2="69 KV" b3="BL-7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48290</SeqNum>
    <Name>138/69.Darby.BK-7 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-27T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DARBY" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DARBY" b2="138 KV" b3="BH-7" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DARBY" b2="69 KV" b3="BL-7" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DARBY" b2="69 KV" b3="CAPW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARBY" b2="69 KV" b3="CG-66CW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48300</SeqNum>
    <Name>138/69.Eldean.T7 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-26T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELDEAN1" b2="138 KV" b3="BH-7" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELDEAN1" b2="138 KV" b3="BK-7XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDEAN1" b2="69 KV" b3="OR-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48310</SeqNum>
    <Name>138/69.Carlisle.T7 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-26T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="09NCARLI" b2="138 KV" b3="BH-7" />
      <ContingencyEquipment Action="X" Type="XF" b1="09NCARLI" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="09NCARLI" b2="69 KV" b3="BL-7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48320</SeqNum>
    <Name>138/69.Overlook.BK-7 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-26T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="09OVERLK" b2="138 KV" b3="BH-7" />
      <ContingencyEquipment Action="X" Type="XF" b1="09OVERLK" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09OVERLK" b2="69 KV" b3="BL-7E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09OVERLK" b2="69 KV" b3="BL-7W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48330</SeqNum>
    <Name>138/69.Urbana.T7 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-01T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="09URBANA" b2="138 KV" b3="BH-7" />
      <ContingencyEquipment Action="X" Type="XF" b1="09URBANA" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09URBANA" b2="69 KV" b3="DB-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09URBANA" b2="69 KV" b3="DB-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48340</SeqNum>
    <Name>L345.Palisades-Roosevelt (CONS)</Name>
    <LastEdit Timestamp="2026-05-11T15:51:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="31H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="31R8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROOSEVLT" b2="345 KV" b3="26H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROOSEVLT" b2="345 KV" b3="26R8" />
      <ContingencyEquipment Action="L" Type="LN" b1="PALISAD2" b2="345 KV" b3="PAL-ROO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48350</SeqNum>
    <Name>L345.Liberty-Prospect.15424 + 345/138.Liberty.T83</Name>
    <LastEdit Timestamp="2026-05-29T12:46:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="154 LIBE" b2="345 KV" b3="15424" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="154 LIBE" b2="34.5 KV" b3="34C1TR83" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="154 LIBE" b2="34.5 KV" b3="34C2TR83" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="154 LIBE" b2="34.5 KV" b3="34C3TR83" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="154 LIBE" b2="34.5 KV" b3="34C4TR83" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="154 LIBE" b2="34.5 KV" b3="34C5TR83" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="154 LIBE" b2="34.5 KV" b3="34C6TR83" />
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="154 LIBE" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="154 LIBE" b2="138 KV" b3="TR83CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="154 LIBE" b2="34.5 KV" b3="TR83CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48370</SeqNum>
    <Name>345/138.154Libertyville.T81 R</Name>
    <LastEdit Timestamp="2024-11-27T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="154 LIBE" b2="345 KV" b3="TR81 CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="154 LIBE" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="154 LIBE" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48380</SeqNum>
    <Name>345/138.Libertyville.T83 R</Name>
    <LastEdit Timestamp="2026-05-28T09:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="154 LIBE" b2="345 KV" b3="TR83 CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="154 LIBE" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="154 LIBE" b2="138 KV" b3="TR83CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="154 LIBE" b2="34.5 KV" b3="TR83CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48440</SeqNum>
    <Name>138/69.Bethany.T1</Name>
    <LastEdit Timestamp="2026-05-27T13:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="69 KV" b3="7510" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="69 KV" b3="7560" />
      <ContingencyEquipment Action="X" Type="XF" b1="BETHANY" b2="138 KV" b3="AT-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48470</SeqNum>
    <Name>500/230.WaughChapel.500-4</Name>
    <LastEdit Timestamp="2025-10-06T11:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="23044BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="2328OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="2340OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="23414BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="2342OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="2343OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="500 KV" b3="4TR_5053" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="500-34B" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAUGHCHA" b2="500 KV" b3="500-4 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="500 KV" b3="500-4CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="M230 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WAUGHCHA" b2="230 KV" b3="M230CAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48510</SeqNum>
    <Name>L138.LumsPond-MtPleasant.13842</Name>
    <LastEdit Timestamp="2026-05-28T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LUMSPOND" b2="138 KV" b3="LUM-MTP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMSPOND" b2="138 KV" b3="PCB 133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTPLEASN" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTPLEASN" b2="138 KV" b3="132" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48540</SeqNum>
    <Name>EvertsDrive.Armenia.WF</Name>
    <LastEdit Timestamp="2026-05-29T12:47:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="EVERTSUB" b2="34.5 KV" b3="ARMENIA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERTSUB" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERTSUB" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="EVERTSUB" b2="34.5 KV" b3="CAP11" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="EVERTSUB" b2="34.5 KV" b3="CAP12" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="EVERTSUB" b2="34.5 KV" b3="CAP13" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="EVERTSUB" b2="34.5 KV" b3="CAP14" />
      <ContingencyEquipment Action="X" Type="XF" b1="EVERTSUB" b2="115 KV" b3="GSU1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48560</SeqNum>
    <Name>L345.GoodingsGrove-KatydidRd.19601</Name>
    <LastEdit Timestamp="2026-05-28T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="196 KATY" b2="345 KV" b3="19601" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="L19601" />
      <ContingencyEquipment Action="OP" Type="CB" b1="196 KATY" b2="345 KV" b3="BT4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="196 KATY" b2="345 KV" b3="BT4-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48570</SeqNum>
    <Name>L115.Allegheny-NewBaltimore</Name>
    <LastEdit Timestamp="2025-03-14T09:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLEGHEN" b2="115 KV" b3="2 TX" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLEGHEN" b2="115 KV" b3="ALL-NEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLEGHEN" b2="115 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEW_BALT" b2="115 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEW_BALT" b2="115 KV" b3="CB2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48580</SeqNum>
    <Name>L115.BedfordNorth-NewBaltimore</Name>
    <LastEdit Timestamp="2026-05-28T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEDFORD" b2="115 KV" b3="BED-NEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEW_BALT" b2="115 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEW_BALT" b2="115 KV" b3="CB3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48590</SeqNum>
    <Name>Katydid.TopCrop.WF</Name>
    <LastEdit Timestamp="2025-07-29T14:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="196 KATY" b2="34.5 KV" b3="3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="196 KATY" b2="345 KV" b3="GCB152" />
      <ContingencyEquipment Action="U" Type="GEN" b1="196 KATY" b2="34.5 KV" b3="TCROPWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="196 KATY" b2="345 KV" b3="TR86" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48600</SeqNum>
    <Name>345/138.Brokaw.45TR1 (AMRN)</Name>
    <LastEdit Timestamp="2025-11-25T16:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="345 KV" b3="4539" />
      <ContingencyEquipment Action="X" Type="XF" b1="BROKAW" b2="345 KV" b3="45TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="345 KV" b3="BT4536" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="138 KV" b3="H11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="138 KV" b3="H21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="138 KV" b3="H31" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48610</SeqNum>
    <Name>L138.Conaway-NorthSeaford.13767</Name>
    <LastEdit Timestamp="2026-05-28T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONAWAY" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONAWAY" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONAWAY" b2="138 KV" b3="CON-NSE7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="138 KV" b3="8370" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48620</SeqNum>
    <Name>L138.Conaway-IndianRiver.13766</Name>
    <LastEdit Timestamp="2026-05-28T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONAWAY" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONAWAY" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONAWAY" b2="138 KV" b3="CON-IND6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="8080" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="8090" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48640</SeqNum>
    <Name>138/69.IndianRiver.AT1</Name>
    <LastEdit Timestamp="2026-05-27T13:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDIANRI" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48660</SeqNum>
    <Name>345/138.DonMarquis.T3 + L345.DonMarquis-Doex530</Name>
    <LastEdit Timestamp="2024-10-30T14:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="345 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="345 KV" b3="E2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="138 KV" b3="M2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARQUIS2" b2="345 KV" b3="MAR-DOE2" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARQUIS2" b2="345 KV" b3="XF3" />
      <ContingencyEquipment Action="S" Type="SD" b1="MARQUIS2" b2="345 KV" b3="_MARQUIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48670</SeqNum>
    <Name>L69.Easton-BloomfieldTap-GraceStreet-Bozman.6782</Name>
    <LastEdit Timestamp="2025-05-06T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLOOMFLD" b2="69 KV" b3="BLO-EAS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLOOMFLD" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOZMAN" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOZMAN" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="69 KV" b3="7450" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="69 KV" b3="7460" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLOOMFLD" b2="69 KV" b3="BLO-GRAC" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOZMAN" b2="69 KV" b3="BOZ-GRAC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRACEST" b2="69 KV" b3="T1 LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRACEST" b2="69 KV" b3="T2 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48680</SeqNum>
    <Name>L69.Easton-RoyalOakTap-Bozman.6785</Name>
    <LastEdit Timestamp="2026-05-28T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOZMAN" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOZMAN" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOZMAN" b2="69 KV" b3="BOZ-ROY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTON" b2="69 KV" b3="EAS-ROY" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROYOAK" b2="69 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48920</SeqNum>
    <Name>L138.Marquis-MillsPride-Waverly</Name>
    <LastEdit Timestamp="2024-11-15T11:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MARQUIS2" b2="138 KV" b3="MAR-MIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="138 KV" b3="P2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLSPRI" b2="138 KV" b3="MIL-WAV1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILLSPRI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY2" b2="138 KV" b3="105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY2" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48930</SeqNum>
    <Name>L345.TrimbleCounty-Speed (LGEE/CIN)</Name>
    <LastEdit Timestamp="2026-05-11T15:42:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPEED" b2="345 KV" b3="30-39" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPEED" b2="345 KV" b3="B3-30" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPEED" b2="345 KV" b3="TRI-SPE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="4515_70" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="TC_4570" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48940</SeqNum>
    <Name>L345.Ghent-TrimbleCounty (LGEE)</Name>
    <LastEdit Timestamp="2026-05-29T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_932" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_934" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="4572_TR5" />
      <ContingencyEquipment Action="L" Type="LN" b1="GHENT_LG" b2="345 KV" b3="GHE-TRI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="TC_4572" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48950</SeqNum>
    <Name>345/4.1 Lasalle.TR242</Name>
    <LastEdit Timestamp="2026-02-10T09:14:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT1-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT4-6 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="1 LASALL" b2="345 KV" b3="TR24204" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48960</SeqNum>
    <Name>345/4.1 Lasalle.TR142</Name>
    <LastEdit Timestamp="2026-02-10T09:14:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT1-13CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1 LASALL" b2="345 KV" b3="BT1113CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="1 LASALL" b2="345 KV" b3="TR14204" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48970</SeqNum>
    <Name>DTX345.3Powerton.TR543</Name>
    <LastEdit Timestamp="2026-02-10T09:15:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT1-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT5-6CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="3 POWERT" b2="345 KV" b3="TR54304" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48980</SeqNum>
    <Name>DTX345.Powerton.ATR643</Name>
    <LastEdit Timestamp="2026-02-10T09:16:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT5-8CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="345 KV" b3="BT8-11CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="3 POWERT" b2="345 KV" b3="TR64304" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>48990</SeqNum>
    <Name>345/4.QuadCities.T81 &amp; T12</Name>
    <LastEdit Timestamp="2026-02-10T09:16:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="4 QUAD C" b2="345 KV" b3="ATR12_04" />
      <ContingencyEquipment Action="X" Type="XF" b1="4 QUAD C" b2="345 KV" b3="ATR81 13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT4-6 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="4 QUAD C" b2="13.5 KV" b3="LATR81LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49000</SeqNum>
    <Name>345/4.QuadCities.T82 &amp; T22</Name>
    <LastEdit Timestamp="2026-02-10T09:17:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="4 QUAD C" b2="345 KV" b3="ATR22_04" />
      <ContingencyEquipment Action="X" Type="XF" b1="4 QUAD C" b2="345 KV" b3="ATR82 13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="4 QUAD C" b2="13.5 KV" b3="LATR82LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49010</SeqNum>
    <Name>345/4.6 Byron.TR142</Name>
    <LastEdit Timestamp="2026-02-10T09:18:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="6 BYRON" b2="345 KV" b3="AT1422LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="6 BYRON" b2="345 KV" b3="T142104" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49020</SeqNum>
    <Name>345/4.6 Byron.TR242</Name>
    <LastEdit Timestamp="2026-02-10T09:20:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="13-14" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="6 BYRON" b2="345 KV" b3="AT2422LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="BT1213CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="6 BYRON" b2="345 KV" b3="T242104" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49030</SeqNum>
    <Name>138/4.12Dresden.TR22Y04&amp;TR22X04</Name>
    <LastEdit Timestamp="2026-02-10T09:21:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="12 DRESD" b2="138 KV" b3="22B1TRD" />
      <ContingencyEquipment Action="X" Type="XF" b1="12 DRESD" b2="138 KV" b3="ATR22X04" />
      <ContingencyEquipment Action="X" Type="XF" b1="12 DRESD" b2="138 KV" b3="ATR22Y04" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="12 DRESD" b2="4.2 KV" b3="LTR22XLD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="12 DRESD" b2="4.2 KV" b3="LTR22YLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="TR86 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49040</SeqNum>
    <Name>345/4.12 Dresden.TR32</Name>
    <LastEdit Timestamp="2026-02-10T09:23:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="12 DRESD" b2="345 KV" b3="ATR32_04" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT4-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT8-15CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT8-9 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49050</SeqNum>
    <Name>DTX138.13CrawFord.TR58R04</Name>
    <LastEdit Timestamp="2026-02-10T09:23:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B721 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B723 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="C5-6 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="13 CRAWF" b2="138 KV" b3="CAP5" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="13 CRAWF" b2="138 KV" b3="CAP6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="13 CRAWF" b2="138 KV" b3="TR58R04" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49060</SeqNum>
    <Name>DTX138.13Crawford.ATR57R</Name>
    <LastEdit Timestamp="2026-02-10T09:24:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="13 CRAWF" b2="138 KV" b3="TR57R04" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49070</SeqNum>
    <Name>DTX138.16Waukegan.TR4 &amp; TR14</Name>
    <LastEdit Timestamp="2025-04-10T15:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="138 KV" b3="4-14CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="16 WAUKE" b2="138 KV" b3="TR14" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="16 WAUKE" b2="138 KV" b3="TR4 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49080</SeqNum>
    <Name>345/4.20 Braidwood.TR142</Name>
    <LastEdit Timestamp="2026-02-10T09:25:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT4-7 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="20 BRAID" b2="345 KV" b3="T142104" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="20 BRAID" b2="345 KV" b3="TR142_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49090</SeqNum>
    <Name>345/4.20 Braidwood.TR242</Name>
    <LastEdit Timestamp="2026-02-10T09:25:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT1114CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="20 BRAID" b2="345 KV" b3="BT1415CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="20 BRAID" b2="345 KV" b3="T242104" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="20 BRAID" b2="345 KV" b3="TR242_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49100</SeqNum>
    <Name>DTX345.21Kincaid.TR143&amp;TR144</Name>
    <LastEdit Timestamp="2026-02-10T09:27:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="21 KINCA" b2="345 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="21 KINCA" b2="345 KV" b3="BT3-5 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="21 KINCA" b2="345 KV" b3="TR14304" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="21 KINCA" b2="345 KV" b3="TR14404" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49110</SeqNum>
    <Name>500/230.Morrisville.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-12T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MORRISVL" b2="500 KV" b3="H124M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="230 KV" b3="L1T2039" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="230 KV" b3="L1T2040" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MORRISVL" b2="500 KV" b3="SC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="500 KV" b3="SC122" />
      <ContingencyEquipment Action="X" Type="XF" b1="MORRISVL" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49120</SeqNum>
    <Name>L138.186Stewart-94HaumesserRd.18623</Name>
    <LastEdit Timestamp="2024-12-05T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="94 HAURD" b2="138 KV" b3="18623" />
      <ContingencyEquipment Action="OP" Type="CB" b1="186 STEW" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="94 HAURD" b2="138 KV" b3="L18623CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49130</SeqNum>
    <Name>L345.Paddock-KittyHawk</Name>
    <LastEdit Timestamp="2024-12-19T07:34:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHK" b2="345 KV" b3="6824" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHK" b2="345 KV" b3="6826" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADDOCK" b2="345 KV" b3="2206-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADDOCK" b2="345 KV" b3="2214-S" />
      <ContingencyEquipment Action="L" Type="LN" b1="KITTYHK" b2="345 KV" b3="KIT-PADD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49140</SeqNum>
    <Name>L138.Logans Ferry-Highland.Z-60</Name>
    <LastEdit Timestamp="2024-11-21T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HIGH DUQ" b2="138 KV" b3="HIG-LOG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGH DUQ" b2="138 KV" b3="LOGAN60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGANSFE" b2="138 KV" b3="HIGH60" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49150</SeqNum>
    <Name>L345.Babbitt-JuggStreet</Name>
    <LastEdit Timestamp="2025-11-12T13:12:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="345 KV" b3="AC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="345 KV" b3="H019G8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BABBITT" b2="345 KV" b3="BAB-JUGS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49160</SeqNum>
    <Name>L345.Corridor-JugStreet</Name>
    <LastEdit Timestamp="2024-10-23T09:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="345 KV" b3="304C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="345 KV" b3="304S" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORRIDOR" b2="345 KV" b3="COR-JUG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="345 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49170</SeqNum>
    <Name>L230.Glade-Seneca.2017 + Seneca.U1-3</Name>
    <LastEdit Timestamp="2026-05-29T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLADE" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLADE" b2="230 KV" b3="B42" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLADE" b2="230 KV" b3="GLA-SEN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SENECA" b2="13 KV" b3="1GEN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SENECA" b2="13 KV" b3="2GEN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SENECA" b2="13 KV" b3="3GEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SENECA" b2="230 KV" b3="3GEN230" />
      <ContingencyEquipment Action="X" Type="XF" b1="SENECA" b2="230 KV" b3="NO1 230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SENECA" b2="230 KV" b3="NO1 GEN" />
      <ContingencyEquipment Action="X" Type="XF" b1="SENECA" b2="230 KV" b3="NO2 230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SENECA" b2="230 KV" b3="NO2 GEN" />
      <ContingencyEquipment Action="X" Type="XF" b1="SENECA" b2="230 KV" b3="NO3 230" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49180</SeqNum>
    <Name>L230.Ironwood-SouthLebanon.1054</Name>
    <LastEdit Timestamp="2025-06-05T11:58:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONWOOD" b2="230 KV" b3="105452" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONWOOD" b2="230 KV" b3="B52" />
      <ContingencyEquipment Action="L" Type="LN" b1="IRONWOOD" b2="230 KV" b3="IRO-SLE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLEBANON" b2="230 KV" b3="B105422" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLEBANON" b2="230 KV" b3="B50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLEBANON" b2="230 KV" b3="B60" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49200</SeqNum>
    <Name>Edgemoor.HayRoad.CC4 (STM)</Name>
    <LastEdit Timestamp="2026-05-29T12:48:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="13 KV" b3="HAYRD4" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="230 KV" b3="T40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="230 KV" b3="T40 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49210</SeqNum>
    <Name>L138.Logans Ferry-Highland.Z-59</Name>
    <LastEdit Timestamp="2026-06-01T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HIGH DUQ" b2="138 KV" b3="HIG-LOG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGH DUQ" b2="138 KV" b3="LOGAN59" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGANSFE" b2="138 KV" b3="HIGH59" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49220</SeqNum>
    <Name>115.Pumphrey-Ferndale-Shipley</Name>
    <LastEdit Timestamp="2026-05-29T12:48:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FERNDALE" b2="115 KV" b3="110520-2" />
      <ContingencyEquipment Action="S" Type="SD" b1="FERNDALE" b2="115 KV" b3="110520SD" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="FERNDALE" b2="115 KV" b3="110539-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PUMPHREY" b2="115 KV" b3="FER-PUM" />
      <ContingencyEquipment Action="L" Type="LN" b1="FERNDALE" b2="115 KV" b3="FER-SHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="110520" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="528_520" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHIPLEY" b2="115 KV" b3="520-2TR" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SHIPLEY" b2="115 KV" b3="522-5TR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHIPLEY" b2="115 KV" b3="DUMFER" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49230</SeqNum>
    <Name>230/115.Forest.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-10T12:27:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FOREST" b2="230 KV" b3="1 TX" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FOREST" b2="230 KV" b3="A49" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOREST" b2="115 KV" b3="B20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49260</SeqNum>
    <Name>L138.167Plano-14302-143Wolfs.14302</Name>
    <LastEdit Timestamp="2024-12-12T13:55:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="14302" b2="138 KV" b3="14302 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="106 MONT" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="106 MONT" b2="138 KV" b3="L14302CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="143 WOLF" b2="138 KV" b3="14302 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="143 WOLF" b2="138 KV" b3="L14302CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="14302" b2="138 KV" b3="14302 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="14302" b2="138 KV" b3="14302 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="14302" b2="138 KV" b3="14302 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="14302" b2="138 KV" b3="14302 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="167 PLAN" b2="138 KV" b3="14302 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="14302" b2="138 KV" b3="14302 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="14302" b2="138 KV" b3="14302 Z5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="138 KV" b3="L14302CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="521 BRIS" b2="138 KV" b3="1-2 DIS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="521 BRIS" b2="138 KV" b3="SW1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="592 OSWE" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="592 OSWE" b2="138 KV" b3="L14302CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="W507" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="W507" b2="138 KV" b3="L14302 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49270</SeqNum>
    <Name>Claytor.CL3</Name>
    <LastEdit Timestamp="2026-05-29T12:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLAYTOR" b2="11 KV" b3="CL3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="11 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49280</SeqNum>
    <Name>Claytor.CL4</Name>
    <LastEdit Timestamp="2026-05-29T12:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLAYTOR" b2="11 KV" b3="CL4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="11 KV" b3="N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49290</SeqNum>
    <Name>230/115.Lanexa.T3</Name>
    <LastEdit Timestamp="2026-05-27T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="230 KV" b3="H332" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="115 KV" b3="L332" />
      <ContingencyEquipment Action="X" Type="XF" b1="LANEXA" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49300</SeqNum>
    <Name>L500.Kammer-502Jct + 765/500.Kammer.200</Name>
    <LastEdit Timestamp="2024-11-14T15:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="502JCT" b2="500 KV" b3="502-KAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="500 KV" b3="5L_7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="500 KV" b3="5L_8" />
      <ContingencyEquipment Action="X" Type="XF" b1="KAMMER2" b2="765 KV" b3=".200" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="765 KV" b3="MM2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="765 KV" b3="MMB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49310</SeqNum>
    <Name>L500.502Junction-Harrison.521</Name>
    <LastEdit Timestamp="2024-11-14T15:27:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="502JCT" b2="500 KV" b3="502-HAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="500 KV" b3="5L_5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="500 KV" b3="5L_6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR APS" b2="500 KV" b3="HL2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR APS" b2="500 KV" b3="HL3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49320</SeqNum>
    <Name>L500.502Junction-NorthLongview.504</Name>
    <LastEdit Timestamp="2024-11-14T15:27:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="502JCT" b2="500 KV" b3="502-LON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="500 KV" b3="5L_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="500 KV" b3="5L_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLONGVW" b2="500 KV" b3="NLVL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLONGVW" b2="500 KV" b3="NLVL2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49330</SeqNum>
    <Name>230/115.Elmont.TX6</Name>
    <LastEdit Timestamp="2026-05-27T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="H692" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="115 KV" b3="L692" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELMONT4" b2="230 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49340</SeqNum>
    <Name>L230.LadysmithCT-StJohns-FourRivers.256 + SJ.T2</Name>
    <LastEdit Timestamp="2025-06-06T12:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FOURRIVR" b2="230 KV" b3="256A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="230 KV" b3="256T2061" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="230 KV" b3="256T2125" />
      <ContingencyEquipment Action="L" Type="LN" b1="LADYSMCT" b2="230 KV" b3="256" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMCT" b2="230 KV" b3="25672" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMCT" b2="230 KV" b3="256T2090" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS4" b2="230 KV" b3="H262" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49350</SeqNum>
    <Name>L230.LadysmithCT-NewPost.2090</Name>
    <LastEdit Timestamp="2025-10-24T12:55:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMCT" b2="230 KV" b3="209072" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMCT" b2="230 KV" b3="256T2090" />
      <ContingencyEquipment Action="L" Type="LN" b1="LADYSMCT" b2="230 KV" b3="LAD-NEWP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPOST" b2="230 KV" b3="209052-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPOST" b2="230 KV" b3="209052-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49360</SeqNum>
    <Name>L345.Arsenal-BrunotIsland.306</Name>
    <LastEdit Timestamp="2025-01-24T14:30:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARSENAL" b2="345 KV" b3="ARS-BRU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="345 KV" b3="TIE 3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="345 KV" b3="TIE 4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="345 KV" b3="ARS306" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49370</SeqNum>
    <Name>L345.Arsenal-LogansFrry.308+345/138.LognsFrry.T1</Name>
    <LastEdit Timestamp="2025-01-15T18:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARSENAL" b2="345 KV" b3="ARS-LOG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="345 KV" b3="TIE 2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="345 KV" b3="TIE 3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGANSFE" b2="138 KV" b3="BUSTIE14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGANSFE" b2="138 KV" b3="BUSTIE34" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOGANSFE" b2="345 KV" b3="TRAN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49460</SeqNum>
    <Name>500/230.Deans.500-3</Name>
    <LastEdit Timestamp="2026-05-28T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DEANS" b2="500 KV" b3="500-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="500 KV" b3="SECT 1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="500 KV" b3="SECT 7-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="230 KV" b3="SECT2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="230 KV" b3="SECT9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49470</SeqNum>
    <Name>345/138.Hiple.T1 (NIPSCO)</Name>
    <LastEdit Timestamp="2024-11-18T13:03:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HIPLE" b2="345 KV" b3="1XFMR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="138 KV" b3="1_XFM_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34524A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34526" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34529-00" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34536" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="EBR_BKR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HIPLE" b2="345 KV" b3="SR_EAST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="138 KV" b3="X109" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49480</SeqNum>
    <Name>345/138.Hiple.T2 (NIPSCO)</Name>
    <LastEdit Timestamp="2024-11-18T13:04:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="138 KV" b3="138103" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIPLE" b2="345 KV" b3="2XFMR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="138 KV" b3="2_XFM_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34524" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34525" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34529" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34537" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HIPLE" b2="345 KV" b3="SR_WEST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="WBR_BKR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49490</SeqNum>
    <Name>LickRun.Casselman.WF</Name>
    <LastEdit Timestamp="2026-05-29T12:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LICKRUN" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICKRUN" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LICKRUN" b2="25 KV" b3="CASSELWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="LICKRUN" b2="115 KV" b3="GSU1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49500</SeqNum>
    <Name>L115.LickRun-Rockwood</Name>
    <LastEdit Timestamp="2025-09-12T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LICKRUN" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICKRUN" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LICKRUN" b2="115 KV" b3="LIC-ROC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKWOOD" b2="115 KV" b3="B36" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKWOOD" b2="115 KV" b3="BSSEC115" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49520</SeqNum>
    <Name>(NUKE)Salem.U1</Name>
    <LastEdit Timestamp="2024-10-10T13:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="SALEM" b2="500 KV" b3="DUMNUK10" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SALEM" b2="500 KV" b3="DUMNUKE1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SALEM" b2="500 KV" b3="DUMNUKE2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SALEM" b2="500 KV" b3="DUMNUKE5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SALEM" b2="500 KV" b3="DUMNUKE6" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SALEM" b2="500 KV" b3="DUMNUKE8" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SALEM" b2="500 KV" b3="DUMNUKE9" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SALEM" b2="25 KV" b3="SALEM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49530</SeqNum>
    <Name>(NUKE)Salem.U2</Name>
    <LastEdit Timestamp="2024-10-10T13:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="SALEM" b2="500 KV" b3="DUMNUK10" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SALEM" b2="500 KV" b3="DUMNUKE1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SALEM" b2="500 KV" b3="DUMNUKE2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SALEM" b2="500 KV" b3="DUMNUKE5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SALEM" b2="500 KV" b3="DUMNUKE6" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SALEM" b2="500 KV" b3="DUMNUKE8" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SALEM" b2="500 KV" b3="DUMNUKE9" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SALEM" b2="25 KV" b3="SALEM2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49540</SeqNum>
    <Name>(NUKE) HopeCreek.U1</Name>
    <LastEdit Timestamp="2024-10-10T13:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="HOPECREE" b2="500 KV" b3="DUMNUKE1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HOPECREE" b2="500 KV" b3="DUMNUKE2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HOPECREE" b2="500 KV" b3="DUMNUKE3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HOPECREE" b2="500 KV" b3="DUMNUKE5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HOPECREE" b2="500 KV" b3="DUMNUKE6" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOPECREE" b2="500 KV" b3="NO 1GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="SECT2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="SECT5-6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HOPECREE" b2="25 KV" b3="UNIT 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49580</SeqNum>
    <Name>(NUKE)Susquehanna.U1</Name>
    <LastEdit Timestamp="2026-04-20T12:53:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQT10" b2="230 KV" b3="DUM2DIS1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUSQUEHA" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUK13" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUK14" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUKE1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUKE2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUKE3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUKE5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUKE6" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUKE7" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUKE9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="SYNCHRO" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SUSQUEHA" b2="24 KV" b3="UNIT01" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49590</SeqNum>
    <Name>(NUKE)Susquehanna.U2</Name>
    <LastEdit Timestamp="2026-02-11T12:23:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQT10" b2="230 KV" b3="DUM2DIS1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUSQUEHA" b2="500 KV" b3="2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUK13" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUK14" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUKE1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUKE2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUKE3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUKE5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUKE6" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUKE7" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUSQUEHA" b2="230 KV" b3="DUMNUKE9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="500 KV" b3="GEN_2-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="500 KV" b3="GEN_2-S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUSQUEHA" b2="69 KV" b3="LD3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUSQUEHA" b2="24 KV" b3="T12" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUSQUEHA" b2="500 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="500 KV" b3="T3-T4_CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SUSQUEHA" b2="24 KV" b3="UNIT02" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49610</SeqNum>
    <Name>Edgemoor.HayRoad.CC4+3</Name>
    <LastEdit Timestamp="2026-05-29T12:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="13 KV" b3="HAYRD1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="13 KV" b3="HAYRD2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="13 KV" b3="HAYRD3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="13 KV" b3="HAYRD4" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="138 KV" b3="T10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="T10   SF" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="69 KV" b3="T20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="69 KV" b3="T20   SF" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="138 KV" b3="T30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="T30   SF" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="230 KV" b3="T40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="230 KV" b3="T40 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49620</SeqNum>
    <Name>Cumberland.CT2</Name>
    <LastEdit Timestamp="2026-05-29T12:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CUMB AE" b2="13.8 KV" b3="CT 2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CUMB AE" b2="230 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="230 KV" b3="PCB20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49680</SeqNum>
    <Name>Crisfield.CT1-4</Name>
    <LastEdit Timestamp="2024-06-12T15:09:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISFIE" b2="12 KV" b3="140" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CRISFIE" b2="4 KV" b3="G1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CRISFIE" b2="4 KV" b3="G2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CRISFIE" b2="4 KV" b3="G3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CRISFIE" b2="4 KV" b3="G4" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRISFIE" b2="12 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49810</SeqNum>
    <Name>345/138.Brunot Island.T1</Name>
    <LastEdit Timestamp="2026-01-08T09:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNOTIS" b2="345 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="345 KV" b3="T1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="T1 LS CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49820</SeqNum>
    <Name>L138.BrunotIsland-Neville.Z-43</Name>
    <LastEdit Timestamp="2026-05-28T10:44:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNOTIS" b2="138 KV" b3="BRU-NEV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="NEVILTAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEVILLE" b2="138 KV" b3="ARIST CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEVILLE" b2="138 KV" b3="ARISTECH" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEVILLE" b2="138 KV" b3="NEV-NEV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEVILLE" b2="23 KV" b3="T1LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEVILLE" b2="138 KV" b3="XFM1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>49830</SeqNum>
    <Name>L138.Sewickly-Crescent.Z-143</Name>
    <LastEdit Timestamp="2026-05-29T12:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRES DUQ" b2="138 KV" b3="CRE-SEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="138 KV" b3="SEW143_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWICKLY" b2="138 KV" b3="CRE-Z143" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50240</SeqNum>
    <Name>138/69.WCoshoct.T1 + L69.WCoshoct-NCoshoct</Name>
    <LastEdit Timestamp="2026-05-27T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NCOSHOCT" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="X" Type="XF" b1="WCOSHOCT" b2="138 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCOSHOCT" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WCOSHOCT" b2="69 KV" b3="COSH" />
      <ContingencyEquipment Action="L" Type="LN" b1="NCOSHOCT" b2="69 KV" b3="NCO-WCO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50250</SeqNum>
    <Name>L69.WestMoulton-StMarys</Name>
    <LastEdit Timestamp="2026-05-29T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09ST_MRY" b2="69 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMOULTON" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="WMOULTON" b2="69 KV" b3="WMO-09S1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50260</SeqNum>
    <Name>138/69.WestMoulton.T1</Name>
    <LastEdit Timestamp="2025-10-30T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WMOULTON" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMOULTON" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMOULTON" b2="138 KV" b3="M002E5" />
      <ContingencyEquipment Action="X" Type="XF" b1="WMOULTON" b2="138 KV" b3="XFMR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50270</SeqNum>
    <Name>500/230.WaughChapel.500-3</Name>
    <LastEdit Timestamp="2025-10-06T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="500 KV" b3="3TR_5052" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAUGHCHA" b2="500 KV" b3="500-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="500-31B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="500-34B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="500 KV" b3="500-3CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50300</SeqNum>
    <Name>138/69.Zanesville.T1</Name>
    <LastEdit Timestamp="2024-10-31T08:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ZANESVIL" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZANESVIL" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="X" Type="XF" b1="ZANESVIL" b2="138 KV" b3="T1-X" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50310</SeqNum>
    <Name>L345.Hanna-Frances-Petersburg (IPL)</Name>
    <LastEdit Timestamp="2026-05-29T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRANCESC" b2="345 KV" b3="08FRNCK" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANCESC" b2="345 KV" b3="FRA-HAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANCESC" b2="345 KV" b3="FRA-PET" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAIPL" b2="345 KV" b3="24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAIPL" b2="345 KV" b3="25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="3C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50330</SeqNum>
    <Name>L345.Collier-Brunot Island.304</Name>
    <LastEdit Timestamp="2025-01-24T14:30:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNOTIS" b2="345 KV" b3="BRU-COL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="345 KV" b3="COL304" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="304-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="304-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50340</SeqNum>
    <Name>L500.CalvertCliffs-WaughChapel.5051</Name>
    <LastEdit Timestamp="2025-04-23T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="23" />
      <ContingencyEquipment Action="L" Type="LN" b1="CALVERTC" b2="500 KV" b3="CAL-WAU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="500 KV" b3="1TR_5051" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="500 KV" b3="5051" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50350</SeqNum>
    <Name>500/230.Bristers.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-04-03T05:44:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRISTERS" b2="500 KV" b3="H164M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRISTERS" b2="230 KV" b3="H262" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRISTERS" b2="230 KV" b3="L1T2101" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRISTERS" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50360</SeqNum>
    <Name>500/230.Suffolk.T7 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-28T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUFFOLK" b2="500 KV" b3="H744M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="230 KV" b3="L742" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUFFOLK" b2="500 KV" b3="TX7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50370</SeqNum>
    <Name>500/35.Surry.T-RSS1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-11T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SURRY4" b2="500 KV" b3="H104M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="35 KV" b3="L102" />
      <ContingencyEquipment Action="X" Type="XF" b1="SURRY4" b2="500 KV" b3="RSS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50380</SeqNum>
    <Name>500/230.Morrisville.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-28T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MORRISVL" b2="500 KV" b3="H224M" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MORRISVL" b2="230 KV" b3="L224" />
      <ContingencyEquipment Action="X" Type="XF" b1="MORRISVL" b2="500 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50390</SeqNum>
    <Name>500/230.Valley.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-30T14:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="VALLEY4" b2="500 KV" b3="H114M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEY4" b2="230 KV" b3="L112" />
      <ContingencyEquipment Action="X" Type="XF" b1="VALLEY4" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50400</SeqNum>
    <Name>L230.Betzwood-Barbadoes.220-80</Name>
    <LastEdit Timestamp="2024-11-13T13:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BARBADOS" b2="230 KV" b3="345 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARBADOS" b2="35 KV" b3="80 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BARBADOS" b2="230 KV" b3="BAR-BET" />
      <ContingencyEquipment Action="X" Type="XF" b1="BARBADOS" b2="230 KV" b3="BARB 8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETZWOOD" b2="230 KV" b3="805 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50440</SeqNum>
    <Name>345/138.Star(FE).T3</Name>
    <LastEdit Timestamp="2026-05-28T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="226" />
      <ContingencyEquipment Action="X" Type="XF" b1="STAR_FE" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="B248" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="STAR_FE" b2="345 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50460</SeqNum>
    <Name>L230.Cooper-Graceton.220-93</Name>
    <LastEdit Timestamp="2024-11-14T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOPERPE" b2="230 KV" b3="115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOPERPE" b2="230 KV" b3="125" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOPERPE" b2="230 KV" b3="COO-GRA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COOPERPE" b2="34 KV" b3="LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="COOPERPE" b2="230 KV" b3="TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRACETON" b2="230 KV" b3="22093-1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRACETON" b2="230 KV" b3="22093-2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50660</SeqNum>
    <Name>L230.PossumPoint-FullerRoadAquia-AquiaHarbor.252</Name>
    <LastEdit Timestamp="2025-01-03T14:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AQUAHAR" b2="230 KV" b3="252B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUAHAR" b2="230 KV" b3="252T2104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUAHAR" b2="230 KV" b3="252T2120" />
      <ContingencyEquipment Action="L" Type="LN" b1="AQUIA" b2="230 KV" b3="252C1" />
      <ContingencyEquipment Action="X" Type="XF" b1="AQUIA" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AQUIA" b2="34.5 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULLERRD" b2="230 KV" b3="H132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FULLERRD" b2="36.5 KV" b3="LOAD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FULLERRD" b2="36.5 KV" b3="SC132-1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FULLERRD" b2="36.5 KV" b3="SC132-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="FULLERRD" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="25292" />
      <ContingencyEquipment Action="L" Type="LN" b1="FULLERRD" b2="230 KV" b3="252B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="252T2022" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50690</SeqNum>
    <Name>230/69.Hosensack.T2</Name>
    <LastEdit Timestamp="2024-08-21T13:03:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HOSENSAC" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="230 KV" b3="TRAN2-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="230 KV" b3="TRAN2-W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="69 KV" b3="TRAN_2_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="69 KV" b3="TRAN_2_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50700</SeqNum>
    <Name>230/69.Hosensack.T4</Name>
    <LastEdit Timestamp="2024-08-21T13:04:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HOSENSAC" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="230 KV" b3="TRAN_4-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="230 KV" b3="TRAN_4-W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="69 KV" b3="TRAN_4_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="69 KV" b3="TRAN_4_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50710</SeqNum>
    <Name>345/138.Tazewell.T1 (AMIL)</Name>
    <LastEdit Timestamp="2025-11-12T14:27:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWEL2" b2="138 KV" b3="H63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWEL2" b2="138 KV" b3="H65" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAZEWEL2" b2="345 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWEL2" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWEL2" b2="345 KV" b3="V13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50720</SeqNum>
    <Name>345/138.Tazewell.T2 (AMIL)</Name>
    <LastEdit Timestamp="2025-11-12T14:27:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWEL2" b2="138 KV" b3="H51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWEL2" b2="138 KV" b3="H53" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAZEWEL2" b2="345 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWEL2" b2="345 KV" b3="V15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWEL2" b2="345 KV" b3="V45" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50730</SeqNum>
    <Name>L345.MapleRidge-IPVA (AMIL)</Name>
    <LastEdit Timestamp="2025-09-12T13:43:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IPVA" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IPVA" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="L" Type="LN" b1="IPVA" b2="345 KV" b3="IPV-MAPL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLERID" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLERID" b2="345 KV" b3="V9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50750</SeqNum>
    <Name>L230.Valley-Dayton-Harrisonburg.2109</Name>
    <LastEdit Timestamp="2026-06-01T11:35:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DAYTON" b2="230 KV" b3="2109A" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAYTON" b2="230 KV" b3="2109B" />
      <ContingencyEquipment Action="X" Type="XF" b1="DAYTON" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAYTON" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DAYTON" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAYTON" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="230 KV" b3="21092134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="230 KV" b3="210992" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEY4" b2="230 KV" b3="210912-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEY4" b2="230 KV" b3="210912-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50760</SeqNum>
    <Name>L69.CoolSprings-Harbeson.6753</Name>
    <LastEdit Timestamp="2026-06-01T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPRI" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPRI" b2="69 KV" b3="66" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOLSPRI" b2="69 KV" b3="COL-HAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBESON" b2="69 KV" b3="7160" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBESON" b2="69 KV" b3="7170" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50770</SeqNum>
    <Name>L69.Midway-Rehoboth.6751</Name>
    <LastEdit Timestamp="2024-10-02T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAY" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDWAY" b2="69 KV" b3="MID-REH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REHOBOTH" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REHOBOTH" b2="69 KV" b3="90" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50780</SeqNum>
    <Name>L138.13Crawford-67Congress.1321</Name>
    <LastEdit Timestamp="2025-10-09T12:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="13 CRAWF" b2="138 KV" b3="1321 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="P" Type="XF" b1="13 CRAWF" b2="138 KV" b3="P1321" />
      <ContingencyEquipment Action="X" Type="XF" b1="13 CRAWF" b2="138 KV" b3="P1321T38" />
      <ContingencyEquipment Action="X" Type="XF" b1="13 CRAWF" b2="138 KV" b3="Z1321T38" />
      <ContingencyEquipment Action="L" Type="LN" b1="67 CONGR" b2="138 KV" b3="6702" />
      <ContingencyEquipment Action="OP" Type="CB" b1="67 CONGR" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="714 MEDI" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50790</SeqNum>
    <Name>L138.Crawford-Congress.1323</Name>
    <LastEdit Timestamp="2025-10-10T12:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="10-11" />
      <ContingencyEquipment Action="L" Type="LN" b1="13 CRAWF" b2="138 KV" b3="1323 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="P" Type="XF" b1="13 CRAWF" b2="138 KV" b3="P1323" />
      <ContingencyEquipment Action="X" Type="XF" b1="13 CRAWF" b2="138 KV" b3="P1323T38" />
      <ContingencyEquipment Action="X" Type="XF" b1="13 CRAWF" b2="138 KV" b3="Z1323T38" />
      <ContingencyEquipment Action="L" Type="LN" b1="67 CONGR" b2="138 KV" b3="6704" />
      <ContingencyEquipment Action="OP" Type="CB" b1="67 CONGR" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="714 MEDI" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50810</SeqNum>
    <Name>L230.Benning-Ritchie.23002</Name>
    <LastEdit Timestamp="2026-06-01T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="3BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="3CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENNING" b2="230 KV" b3="BEN-RIT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="230 KV" b3="23002B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50850</SeqNum>
    <Name>L138.Congress-Rockwell.6721</Name>
    <LastEdit Timestamp="2025-02-27T13:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="38 HUMBO" b2="138 KV" b3="5004" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="38 HUMBO" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="50 ROCKW" b2="138 KV" b3="6721" />
      <ContingencyEquipment Action="OP" Type="CB" b1="50 ROCKW" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="67 CONGR" b2="138 KV" b3="6701" />
      <ContingencyEquipment Action="OP" Type="CB" b1="67 CONGR" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="714 MEDI" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50860</SeqNum>
    <Name>L138.67Congress-50Rockwell-38HumboldtPark.6723</Name>
    <LastEdit Timestamp="2025-06-20T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="38 HUMBO" b2="138 KV" b3="5002" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="38 HUMBO" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="50 ROCKW" b2="138 KV" b3="6723" />
      <ContingencyEquipment Action="OP" Type="CB" b1="50 ROCKW" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="67 CONGR" b2="138 KV" b3="6703" />
      <ContingencyEquipment Action="OP" Type="CB" b1="67 CONGR" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="714 MEDI" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50870</SeqNum>
    <Name>L138.Crosby-Rockwell.8221</Name>
    <LastEdit Timestamp="2025-06-20T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="38 HUMBO" b2="138 KV" b3="5003" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="38 HUMBO" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="50 ROCKW" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="50 ROCKW" b2="138 KV" b3="8221 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT2-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50880</SeqNum>
    <Name>L138.Crosby-Rockwell.8223</Name>
    <LastEdit Timestamp="2025-06-20T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="38 HUMBO" b2="138 KV" b3="5001" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="38 HUMBO" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="50 ROCKW" b2="138 KV" b3="8223" />
      <ContingencyEquipment Action="OP" Type="CB" b1="50 ROCKW" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1213CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50900</SeqNum>
    <Name>L230.CoolSprings-Milford.23069</Name>
    <LastEdit Timestamp="2026-06-01T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPRI" b2="230 KV" b3="230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPRI" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOLSPRI" b2="230 KV" b3="COL-MIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="230 KV" b3="9390" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50910</SeqNum>
    <Name>L230.CoolSprings-IndianRiver.23070</Name>
    <LastEdit Timestamp="2026-06-01T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPRI" b2="230 KV" b3="230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPRI" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOLSPRI" b2="230 KV" b3="COL-IND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="230 KV" b3="237" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="230 KV" b3="238" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50920</SeqNum>
    <Name>230/69.CoolSprings.AT20</Name>
    <LastEdit Timestamp="2026-06-01T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPRI" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPRI" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPRI" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPRI" b2="69 KV" b3="66" />
      <ContingencyEquipment Action="X" Type="XF" b1="COOLSPRI" b2="230 KV" b3="AT20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50940</SeqNum>
    <Name>L138.Kewanee-Toulon.7421</Name>
    <LastEdit Timestamp="2026-06-01T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="81 TOULO" b2="138 KV" b3="7421" />
      <ContingencyEquipment Action="OP" Type="CB" b1="74 KEWAN" b2="138 KV" b3="L7421 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="81 TOULO" b2="138 KV" b3="L7421 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50950</SeqNum>
    <Name>L138.Powerton-Toulon.0321</Name>
    <LastEdit Timestamp="2026-06-01T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="81 TOULO" b2="138 KV" b3="0321X" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3 POWERT" b2="138 KV" b3="L0321 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="81 TOULO" b2="138 KV" b3="L0321 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50960</SeqNum>
    <Name>L230.AquiaHarbor-Garrisonville.2120</Name>
    <LastEdit Timestamp="2026-06-01T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUAHAR" b2="230 KV" b3="252T2120" />
      <ContingencyEquipment Action="L" Type="LN" b1="AQUAHAR" b2="230 KV" b3="2120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARRSNV" b2="230 KV" b3="H1T2120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARRSNV" b2="230 KV" b3="H2T2120" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50970</SeqNum>
    <Name>L138.Siegfried-Jackson.1</Name>
    <LastEdit Timestamp="2025-01-16T15:59:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="APPENZLL" b2="138 KV" b3="APP-JAC" />
      <ContingencyEquipment Action="L" Type="LN" b1="APPENZLL" b2="138 KV" b3="APP-MCM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="APPENZLL" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEMONT" b2="138 KV" b3="BLU-GIL" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEMONT" b2="138 KV" b3="BLU-SIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLUEMONT" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="EFFRTMTN" b2="138 KV" b3="EFF-GIL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EFFRTMTN" b2="138 KV" b3="EFF-MCM1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EFFRTMTN" b2="138 KV" b3="EMT1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GILBERTT" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PL" b2="138 KV" b3="SIEG CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PL" b2="138 KV" b3="SIEGMONR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCMICHLS" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SIEGFRIE" b2="138 KV" b3="JACKINS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="138 KV" b3="JACKSON1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50980</SeqNum>
    <Name>230/115.Churchland.TX3</Name>
    <LastEdit Timestamp="2025-02-27T10:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRCHLND" b2="230 KV" b3="H352" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRCHLND" b2="115 KV" b3="L352" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHRCHLND" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>50990</SeqNum>
    <Name>NorthAnna.U1</Name>
    <LastEdit Timestamp="2026-02-11T06:49:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="NANNA4" b2="22 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="500 KV" b3="G102-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="500 KV" b3="G102-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="22 KV" b3="G12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NANNA4" b2="22 KV" b3="SS1LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="NANNA4" b2="500 KV" b3="TXG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51000</SeqNum>
    <Name>NorthAnna.U2</Name>
    <LastEdit Timestamp="2026-02-11T06:49:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="NANNA4" b2="22 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="500 KV" b3="G202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="500 KV" b3="G2T575" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NANNA4" b2="22 KV" b3="SS2LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="NANNA4" b2="500 KV" b3="TXG2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51020</SeqNum>
    <Name>L230.Jackson-Yorkana.1052</Name>
    <LastEdit Timestamp="2026-06-01T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="230 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="230 KV" b3="B7" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACK ME" b2="230 KV" b3="JAC-YOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="230 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="230 KV" b3="B43" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51030</SeqNum>
    <Name>230/115.Yorkana.T3</Name>
    <LastEdit Timestamp="2026-05-29T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="YORKANA" b2="230 KV" b3="3 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="115 KV" b3="3B82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="230 KV" b3="B02" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="230 KV" b3="B43" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51100</SeqNum>
    <Name>L345.Lombard-Itasca.12002</Name>
    <LastEdit Timestamp="2024-11-05T14:31:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="345 KV" b3="1-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="101 ITAS" b2="345 KV" b3="12002" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="345 KV" b3="L12002CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51130</SeqNum>
    <Name>L500.Harrison-Pruntytown.526</Name>
    <LastEdit Timestamp="2025-11-13T14:23:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HARR APS" b2="500 KV" b3="HAR-PRU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR APS" b2="500 KV" b3="HL5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR APS" b2="500 KV" b3="HL6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="500 KV" b3="B125" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="500 KV" b3="B126" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51190</SeqNum>
    <Name>230/115.Bowie.T1</Name>
    <LastEdit Timestamp="2026-05-29T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="115 KV" b3="115K1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="115 KV" b3="115K2B" />
      <ContingencyEquipment Action="X" Type="XF" b1="BOWIE" b2="230 KV" b3="162-1T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="230 KV" b3="23044B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="230 KV" b3="23054LB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="230 KV" b3="2340B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51200</SeqNum>
    <Name>230/115.Bowie.T2</Name>
    <LastEdit Timestamp="2026-05-29T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="115 KV" b3="115K4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="115 KV" b3="115K5B" />
      <ContingencyEquipment Action="X" Type="XF" b1="BOWIE" b2="230 KV" b3="162-2T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="230 KV" b3="23043B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="230 KV" b3="23065B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOWIE" b2="230 KV" b3="2341B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51210</SeqNum>
    <Name>230/69.Benning.T8</Name>
    <LastEdit Timestamp="2026-06-01T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="5AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="5BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K11B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K12B" />
      <ContingencyEquipment Action="P" Type="XF" b1="BENNING" b2="69 KV" b3="8T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="8TPL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="8TSL" />
      <ContingencyEquipment Action="X" Type="XF" b1="BENNING" b2="230 KV" b3="STA-8T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51220</SeqNum>
    <Name>230/69.Benning.T9</Name>
    <LastEdit Timestamp="2026-06-01T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="6AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="6BB" />
      <ContingencyEquipment Action="P" Type="XF" b1="BENNING" b2="69 KV" b3="9T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="9TPL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="9TS-MOD" />
      <ContingencyEquipment Action="X" Type="XF" b1="BENNING" b2="230 KV" b3="STA-9T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51250</SeqNum>
    <Name>230/115.Hunterstown.T4</Name>
    <LastEdit Timestamp="2026-05-29T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HUNTERST" b2="230 KV" b3="4 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="115 KV" b3="B138" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="230 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51280</SeqNum>
    <Name>765/138.Amos.T6</Name>
    <LastEdit Timestamp="2024-10-17T15:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="AMOS" b2="765 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="G CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="S1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="U1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51330</SeqNum>
    <Name>345/138.BentonHarbor.T1</Name>
    <LastEdit Timestamp="2025-11-10T11:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BENTONHA" b2="345 KV" b3=".  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="138 KV" b3="F2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51340</SeqNum>
    <Name>230/46.Altoona.T1</Name>
    <LastEdit Timestamp="2025-08-22T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTOONA" b2="230 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTOONA" b2="46 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTOONA" b2="230 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTOONA" b2="230 KV" b3="B44" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ALTOONA" b2="230 KV" b3="CAP" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALTOONA" b2="230 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51350</SeqNum>
    <Name>230/46.Altoona.T2</Name>
    <LastEdit Timestamp="2025-08-26T17:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTOONA" b2="46 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTOONA" b2="230 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTOONA" b2="230 KV" b3="B50" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALTOONA" b2="230 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51370</SeqNum>
    <Name>L138.Jackson-TannersV-BartonV-Stroudsburg-Monroe.1</Name>
    <LastEdit Timestamp="2026-05-12T09:51:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRTNSVIL" b2="138 KV" b3="7839" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRTNSVIL" b2="138 KV" b3="BAR-NST2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRTNSVIL" b2="138 KV" b3="BAR-TAN2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BRTNSVIL" b2="138 KV" b3="DUM1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACK PL" b2="138 KV" b3="JAC-TAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PL" b2="138 KV" b3="MONR_2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PL" b2="138 KV" b3="SIEGMON2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR PL" b2="138 KV" b3="JKSN2 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONR PL" b2="138 KV" b3="MON-STR2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NSTRDSBG" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSTRDSBG" b2="138 KV" b3="CAP2CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NSTRDSBG" b2="138 KV" b3="LOAD2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STRDSBG" b2="138 KV" b3="LOAD2" />
      <ContingencyEquipment Action="L" Type="LN" b1="STRDSBG" b2="138 KV" b3="STR-NST2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TANNERSV" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51410</SeqNum>
    <Name>138/69.WyeMills.AT2</Name>
    <LastEdit Timestamp="2025-09-08T09:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="138 KV" b3="133 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="7530" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="138 KV" b3="8680" />
      <ContingencyEquipment Action="X" Type="XF" b1="WYEMILLS" b2="138 KV" b3="AT-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51480</SeqNum>
    <Name>L500.Suffolk-Yadkin.565</Name>
    <LastEdit Timestamp="2025-06-04T14:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="500 KV" b3="531T565" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUFFOLK" b2="500 KV" b3="565A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="500 KV" b3="H7T565" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="500 KV" b3="H1T565" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="500 KV" b3="H2T565" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51530</SeqNum>
    <Name>L138.MeadowBrook-Hampshire-Ridgeley</Name>
    <LastEdit Timestamp="2026-01-27T10:35:12" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMPSHIR" b2="138 KV" b3="CS1325" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMPSHIR" b2="138 KV" b3="CS1326" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAMPSHIR" b2="138 KV" b3="HAM-MEA" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAMPSHIR" b2="138 KV" b3="HAM-RID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGELEY" b2="138 KV" b3="HAMPSHIR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51540</SeqNum>
    <Name>L138.Gore-Hampshire-FrenchsMill</Name>
    <LastEdit Timestamp="2025-12-18T15:50:00" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENCHSM" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRENCHSM" b2="138 KV" b3="FRE-HAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENCHSM" b2="34.5 KV" b3="T2LCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FRENCHSM" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORE APS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GORE APS" b2="138 KV" b3="GOR-HAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMPSHIR" b2="138 KV" b3="CS1325" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMPSHIR" b2="138 KV" b3="CS1326" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51610</SeqNum>
    <Name>345/138.Avonlake.AVT91</Name>
    <LastEdit Timestamp="2025-02-07T11:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="AVONLAK2" b2="345 KV" b3="91-AVT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="345 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="345 KV" b3="B352" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51620</SeqNum>
    <Name>345/138.Avonlake.AVT92</Name>
    <LastEdit Timestamp="2025-02-27T13:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="AVONLAK2" b2="345 KV" b3="92-AVT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="345 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="138 KV" b3="B25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="345 KV" b3="B354" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51640</SeqNum>
    <Name>L345.Carlisle-NorthMedina</Name>
    <LastEdit Timestamp="2026-06-02T11:31:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="345 KV" b3="8" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARLISLE" b2="345 KV" b3="CAR-NME" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_MEDINA" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_MEDINA" b2="345 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51660</SeqNum>
    <Name>L345.Fox-Harding.S-8</Name>
    <LastEdit Timestamp="2025-03-14T10:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="345 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="345 KV" b3="B27" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDING2" b2="345 KV" b3="HAR-FOX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B29" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51670</SeqNum>
    <Name>L345.Fox-Harding.S-9</Name>
    <LastEdit Timestamp="2025-03-14T10:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="345 KV" b3="B25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="345 KV" b3="B26" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDING2" b2="345 KV" b3="HAR-FOX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B32" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51680</SeqNum>
    <Name>L345.Hanna-CantonCentral</Name>
    <LastEdit Timestamp="2026-01-06T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CANTONCE" b2="345 KV" b3="CAN-HAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="345 KV" b3="K1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B179" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B182" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51710</SeqNum>
    <Name>345/138.Midway.T3</Name>
    <LastEdit Timestamp="2026-06-01T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MIDWAYTE" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13211" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="345 KV" b3="B34534" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="345 KV" b3="B34535" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51720</SeqNum>
    <Name>L345.Crescent-Mansfield</Name>
    <LastEdit Timestamp="2026-06-01T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRES DUQ" b2="345 KV" b3="CRS-MAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="MANSFIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="MANSFIE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="65" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51730</SeqNum>
    <Name>L345.Beaver-WestLorain + WestLorain.WL20-WL50</Name>
    <LastEdit Timestamp="2025-01-09T14:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="159" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="160" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="179" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="B161" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEAVER" b2="13.8 KV" b3="WL20" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEAVER" b2="13.8 KV" b3="WL30" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEAVER" b2="13.8 KV" b3="WL40" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEAVER" b2="13.8 KV" b3="WL50" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51740</SeqNum>
    <Name>L345.BeaverValley-Sammis.312</Name>
    <LastEdit Timestamp="2025-07-28T11:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="312-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAV DUQ" b2="345 KV" b3="312-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAV DUQ" b2="345 KV" b3="BEA-SAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="345 KV" b3="456" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="345 KV" b3="459" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51760</SeqNum>
    <Name>L345.Sammis-SouthCanton</Name>
    <LastEdit Timestamp="2026-01-06T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="345 KV" b3="287" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="345 KV" b3="290" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCANTON2" b2="345 KV" b3="SCA-SAM1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51770</SeqNum>
    <Name>L345.Sammis-Star</Name>
    <LastEdit Timestamp="2026-01-06T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="345 KV" b3="11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="345 KV" b3="17" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAMMISFE" b2="345 KV" b3="SAM-STA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51780</SeqNum>
    <Name>L138.AllenJunction-Jackman</Name>
    <LastEdit Timestamp="2026-06-01T11:36:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENJUN" b2="138 KV" b3="ALL-ALLE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="138 KV" b3="B13375" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLENMOD" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKMAN" b2="138 KV" b3="3332" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENMOD" b2="138 KV" b3="ALL-JAC2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51800</SeqNum>
    <Name>L138.Babb-Valley</Name>
    <LastEdit Timestamp="2026-06-01T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABB" b2="138 KV" b3="9" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BABB" b2="138 KV" b3="A11" />
      <ContingencyEquipment Action="L" Type="LN" b1="VALLEYOE" b2="138 KV" b3="VAL-BAB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEYOE" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="VALLEYOE" b2="138 KV" b3="A 27" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51810</SeqNum>
    <Name>L138.Babb-West Akron</Name>
    <LastEdit Timestamp="2026-06-01T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABB" b2="138 KV" b3="95" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BABB" b2="138 KV" b3="A93" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAKRON" b2="138 KV" b3="WAK-BAB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKRON" b2="138 KV" b3="B159" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51820</SeqNum>
    <Name>L138.Barberton-Alcoa-West Akron</Name>
    <LastEdit Timestamp="2026-06-02T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALCOAFE" b2="138 KV" b3="ALCOA LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARBERTO" b2="138 KV" b3="36" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BARBERTO" b2="138 KV" b3="A 199" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCOAFE" b2="138 KV" b3="ALC-BAR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WAKRON" b2="138 KV" b3="A 129" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCOAFE" b2="138 KV" b3="ALC-WAK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKRON" b2="138 KV" b3="B214" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51830</SeqNum>
    <Name>L138.Barberton-Cloverdale</Name>
    <LastEdit Timestamp="2025-11-17T16:00:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BARBERTO" b2="138 KV" b3="37" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BARBERTO" b2="138 KV" b3="A 198" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVEROE" b2="138 KV" b3="CLO-BAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="138 KV" b3="B102" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLOVEROE" b2="138 KV" b3="D12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51840</SeqNum>
    <Name>L138.Avery-Hayes</Name>
    <LastEdit Timestamp="2025-12-10T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HAYES_FE" b2="138 KV" b3="AVE-HAYE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVERY" b2="138 KV" b3="B29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVERY" b2="138 KV" b3="B85" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="138 KV" b3="B42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="138 KV" b3="B45" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51850</SeqNum>
    <Name>L138.Avery-Shinrock</Name>
    <LastEdit Timestamp="2026-06-02T11:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AVERY" b2="138 KV" b3="AVE-SHI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVERY" b2="138 KV" b3="B36" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVERY" b2="138 KV" b3="B85" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHINROCK" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHINROCK" b2="138 KV" b3="42" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51860</SeqNum>
    <Name>L138.Bayshore-Decant</Name>
    <LastEdit Timestamp="2025-08-06T14:44:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02DECANT" b2="138 KV" b3="3280" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DECANT" b2="138 KV" b3="3322" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYSHOR2" b2="138 KV" b3="BAY-02D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="138 KV" b3="B13257" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51870</SeqNum>
    <Name>L138.Boardman-Shenango</Name>
    <LastEdit Timestamp="2026-06-02T11:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BOARDMAN" b2="138 KV" b3="A156" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOARDMAN" b2="138 KV" b3="B82" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOARDMAN" b2="138 KV" b3="BOA-SHE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51880</SeqNum>
    <Name>L138.Beaver-FordLorain</Name>
    <LastEdit Timestamp="2026-06-03T10:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORDFE" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORDFE" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVER" b2="138 KV" b3="BEA-FOR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51900</SeqNum>
    <Name>L138.Beaver-NASABay</Name>
    <LastEdit Timestamp="2026-06-03T10:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="127" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NASA" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVER" b2="138 KV" b3="BEA-NAS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51910</SeqNum>
    <Name>L138.Bayshore-GMPowerTrain</Name>
    <LastEdit Timestamp="2025-11-12T14:28:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="138 KV" b3="B13251" />
      <ContingencyEquipment Action="L" Type="LN" b1="GM_PWR" b2="138 KV" b3="GMP-BAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GM_PWR" b2="138 KV" b3="B13296" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51920</SeqNum>
    <Name>L138.Bayshore-CNR-Jeep 2</Name>
    <LastEdit Timestamp="2025-08-06T13:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02JP" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="CNR_TAP" b2="138 KV" b3="CNR-JEE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="138 KV" b3="B13256" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYSHOR2" b2="138 KV" b3="BAY-CNRT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CNR_TAP" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51940</SeqNum>
    <Name>L138.Bluebell-Knox</Name>
    <LastEdit Timestamp="2026-06-02T11:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BLUEBELL" b2="138 KV" b3="A110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEBELL" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEBELL" b2="138 KV" b3="BLU-KNO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOX" b2="138 KV" b3="B53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOX" b2="138 KV" b3="B80" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51950</SeqNum>
    <Name>L138.Bluebell-Pidgeon</Name>
    <LastEdit Timestamp="2026-06-02T11:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BLUEBELL" b2="138 KV" b3="A137" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEBELL" b2="138 KV" b3="B94" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEBELL" b2="138 KV" b3="BLU-PID1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIDGEON" b2="138 KV" b3="63" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51970</SeqNum>
    <Name>L69.Kenney-Stockton.6712-1</Name>
    <LastEdit Timestamp="2025-04-08T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNEY" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNEY" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STOCKTON" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENNEY" b2="69 KV" b3="KEN-STO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STOCKTON" b2="69 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51980</SeqNum>
    <Name>L138.Brookside-Ross-Cloverdale</Name>
    <LastEdit Timestamp="2025-11-17T16:01:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKSID" b2="138 KV" b3="A96" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSID" b2="138 KV" b3="B30" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKSID" b2="138 KV" b3="BRO-ROS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="138 KV" b3="B288" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVEROE" b2="138 KV" b3="CLO-ROS1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLOVEROE" b2="138 KV" b3="D43" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROSSOE" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>51990</SeqNum>
    <Name>L138.Bookside-Milliron-Leaside</Name>
    <LastEdit Timestamp="2025-03-24T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKSID" b2="138 KV" b3="A100" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSID" b2="138 KV" b3="B36" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKSID" b2="138 KV" b3="BRO-MIL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LESIDE" b2="138 KV" b3="29" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLIRON" b2="138 KV" b3="MIL-LES1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLIRON" b2="138 KV" b3="CI2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILLIRON" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52000</SeqNum>
    <Name>L138.Bluebell-Repubsm-Commerce-Highland</Name>
    <LastEdit Timestamp="2026-06-03T10:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BLUEBELL" b2="138 KV" b3="A45" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEBELL" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="REPUBSM" b2="138 KV" b3="REP-BLU" />
      <ContingencyEquipment Action="L" Type="LN" b1="REPUBSM" b2="138 KV" b3="COM-REP" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLAOE" b2="138 KV" b3="HIG-COM1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COMERC" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REPUBSM" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52010</SeqNum>
    <Name>L138.Ashland-Howard</Name>
    <LastEdit Timestamp="2025-09-09T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHLAND" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHLAND" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASHLAND" b2="138 KV" b3="ASH-HOWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52060</SeqNum>
    <Name>L138.Brookside-Henrietta</Name>
    <LastEdit Timestamp="2025-12-23T10:31:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKSID" b2="138 KV" b3="A66" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSID" b2="138 KV" b3="B59" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKSID" b2="138 KV" b3="BRO-TRO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMDEN2" b2="138 KV" b3="CAM-TROY" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAMDEN2" b2="138 KV" b3="LD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HENRIETA" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HENRIETA" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMDEN2" b2="138 KV" b3="CAM-HEN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TROY_LM" b2="138 KV" b3="LD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52110</SeqNum>
    <Name>L345.Avonlake-Juniper</Name>
    <LastEdit Timestamp="2025-09-02T10:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AVONLAK2" b2="345 KV" b3="AVO-JUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="345 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="345 KV" b3="B353" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B36" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52120</SeqNum>
    <Name>L69.Adena-Slate-BiersRun</Name>
    <LastEdit Timestamp="2025-11-21T15:06:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADENA" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="69 KV" b3="K2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ADENA" b2="69 KV" b3="ADE-SLA" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIERSRUN" b2="69 KV" b3="BIE-SLA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SLATE" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SLATE" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52170</SeqNum>
    <Name>L138.Beaver-Johnson</Name>
    <LastEdit Timestamp="2026-06-02T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSOFE" b2="138 KV" b3="104" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="JOHNSOFE" b2="138 KV" b3="A30" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVER" b2="138 KV" b3="BEA-JOH1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52210</SeqNum>
    <Name>L138.AllenJunction-Sylvania-Flower-Talmadge</Name>
    <LastEdit Timestamp="2024-11-27T10:53:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02SYLVNA" b2="138 KV" b3="02S-ALL2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLOWER" b2="138 KV" b3="FLO-SYL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02SYLVNA" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="138 KV" b3="B13374" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLOWER" b2="138 KV" b3="FLO-TAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLOWER" b2="138 KV" b3="LDTR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TALWGATE" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TALWGATE" b2="138 KV" b3="B20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52220</SeqNum>
    <Name>L138.Carlisle-Gates</Name>
    <LastEdit Timestamp="2026-06-02T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="64" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="67" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARLISLE" b2="138 KV" b3="CAR-GAT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GATESOE" b2="138 KV" b3="22" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GATESOE" b2="138 KV" b3="A 7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52230</SeqNum>
    <Name>L138.Carlisle-Lorain</Name>
    <LastEdit Timestamp="2026-06-02T11:23:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02LORAIN" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="58" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="61" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARLISLE" b2="138 KV" b3="CAR-02L1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LORAIN" b2="138 KV" b3="02L-NAT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NATLBRN" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52240</SeqNum>
    <Name>L138.CedarSt-EllwoodQualitySteel-911Ind-NewCastle</Name>
    <LastEdit Timestamp="2025-05-19T15:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="911INDUS" b2="138 KV" b3="911_LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAROE" b2="138 KV" b3="B252" />
      <ContingencyEquipment Action="L" Type="LN" b1="EUTAP" b2="138 KV" b3="EUT-CED1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELW_IND" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELW_IND" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELW_IND" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELW_IND" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="911INDUS" b2="138 KV" b3="911-EUTA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EUTAP" b2="138 KV" b3="ELQST2LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="EUTAP" b2="138 KV" b3="EUT-02E1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EUTAP" b2="138 KV" b3="EUT-PEL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="911INDUS" b2="138 KV" b3="911-NEWC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASOE" b2="138 KV" b3="B166" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="P_EL_UDH" b2="138 KV" b3="LDST" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52250</SeqNum>
    <Name>L138.Chamberlin-Nordonia-Sourek-WestAkron</Name>
    <LastEdit Timestamp="2026-06-03T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B56" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAMBROE" b2="138 KV" b3="CHA-NOR" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORDONIA" b2="138 KV" b3="NOR-SOUR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NORDONIA" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOUREK" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WAKRON" b2="138 KV" b3="A99" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKRON" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOUREK" b2="138 KV" b3="SOU-WAK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52260</SeqNum>
    <Name>L138.Chamberlin-Theiss</Name>
    <LastEdit Timestamp="2026-06-02T11:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B59" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAMBROE" b2="138 KV" b3="CHA-THE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THEISS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THEISS" b2="138 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52270</SeqNum>
    <Name>138/69.Chamberlin.T2</Name>
    <LastEdit Timestamp="2026-06-01T09:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHAMBROE" b2="69 KV" b3="A72" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B69" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="69 KV" b3="B74" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B86" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHAMBROE" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52280</SeqNum>
    <Name>L138.Clark-Airpark-EastSpringfield</Name>
    <LastEdit Timestamp="2026-06-03T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AIRPRKFE" b2="138 KV" b3="AIR-CLA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ESPROHED" b2="138 KV" b3="ESP-AIR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AIRPRKFE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKOE" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKOE" b2="138 KV" b3="B72" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ESPROHED" b2="138 KV" b3="A230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESPROHED" b2="138 KV" b3="B228" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52290</SeqNum>
    <Name>L138.Clark-Greene</Name>
    <LastEdit Timestamp="2026-06-02T11:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKOE" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKOE" b2="138 KV" b3="B65" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENE" b2="138 KV" b3="GRE-CLA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="138 KV" b3="I" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52330</SeqNum>
    <Name>L138.Cloverdale-Star</Name>
    <LastEdit Timestamp="2025-11-17T16:01:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="138 KV" b3="B101" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLOVEROE" b2="138 KV" b3="D42" />
      <ContingencyEquipment Action="L" Type="LN" b1="STAR_FE" b2="138 KV" b3="STA-CLO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="5_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52340</SeqNum>
    <Name>L138.Cloverdale-LegendTap-Torrey</Name>
    <LastEdit Timestamp="2025-11-17T16:03:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLOVEROE" b2="138 KV" b3="A49" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="138 KV" b3="B99" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGENDT" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVEROE" b2="138 KV" b3="CLO-LEGE" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEGENDT" b2="138 KV" b3="LEG-TORR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEGENDT" b2="138 KV" b3="TR1_LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORREY" b2="138 KV" b3="W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52350</SeqNum>
    <Name>L138.Crissinger-NucoreSteel-LTVDefasco-Roberts</Name>
    <LastEdit Timestamp="2025-07-03T13:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02LTV" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISS" b2="138 KV" b3="B122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISS" b2="138 KV" b3="B99" />
      <ContingencyEquipment Action="L" Type="LN" b1="NUCORST" b2="138 KV" b3="NUC-CRI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LTV" b2="138 KV" b3="02L-NUC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NUCORST" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NUCORST" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROBERTOE" b2="138 KV" b3="A134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTOE" b2="138 KV" b3="B132" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROBERTOE" b2="138 KV" b3="ROB-02L1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52360</SeqNum>
    <Name>L138.Crissinger-DelawarePark-Tangy</Name>
    <LastEdit Timestamp="2025-07-17T16:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISS" b2="138 KV" b3="B 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISS" b2="138 KV" b3="B118" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRISS" b2="138 KV" b3="CRI-DEL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELPARK" b2="138 KV" b3="CI2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELPARK" b2="138 KV" b3="DEL-TAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52370</SeqNum>
    <Name>L138.Crossland-Masury.Z-70</Name>
    <LastEdit Timestamp="2026-06-02T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSFE" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="MASURY" b2="138 KV" b3="MAS-CRO1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MASURY" b2="138 KV" b3="A123" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASURY" b2="138 KV" b3="B86" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52380</SeqNum>
    <Name>L138.Crossland-Sharon.Z-112</Name>
    <LastEdit Timestamp="2025-10-10T12:43:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSFE" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROSSFE" b2="138 KV" b3="CRO-SHR1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHARON" b2="138 KV" b3="A66" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARON" b2="138 KV" b3="B64" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHARON" b2="138 KV" b3="SHA-SHR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHRPQS" b2="138 KV" b3="CS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHRPQS" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHRPQS" b2="138 KV" b3="ELLWOOD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHRPQS" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHRPQS" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52400</SeqNum>
    <Name>L138.Dale-Moore-SouthAkron</Name>
    <LastEdit Timestamp="2024-10-31T08:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DALEOE" b2="138 KV" b3="B29" />
      <ContingencyEquipment Action="L" Type="LN" b1="DALEOE" b2="138 KV" b3="DAL-MOO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DALEOE" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAKRONFE" b2="138 KV" b3="SAK-MOO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MOOREOE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SAKRONFE" b2="138 KV" b3="A367" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRONFE" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52410</SeqNum>
    <Name>138/69.Dale.TR1</Name>
    <LastEdit Timestamp="2025-11-17T16:11:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DALEOE" b2="138 KV" b3="B29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DALEOE" b2="138 KV" b3="B36" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DALEOE" b2="69 KV" b3="B_5" />
      <ContingencyEquipment Action="X" Type="XF" b1="DALEOE" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52420</SeqNum>
    <Name>L138.Hanna-Brady</Name>
    <LastEdit Timestamp="2025-08-22T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADYLAK" b2="138 KV" b3="B56" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADYLAK" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANNAOE" b2="138 KV" b3="HAN-BRA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52430</SeqNum>
    <Name>L138.Darrow-Hudson Muni</Name>
    <LastEdit Timestamp="2025-08-04T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARROW" b2="138 KV" b3="B115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARROW" b2="138 KV" b3="B116" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUDMUN" b2="138 KV" b3="HUD-DAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDMUN" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDMUN" b2="138 KV" b3="3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52450</SeqNum>
    <Name>138/69.Darrow.TR2</Name>
    <LastEdit Timestamp="2025-07-31T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARROW" b2="138 KV" b3="B114" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARROW" b2="138 KV" b3="B115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARROW" b2="69 KV" b3="B79" />
      <ContingencyEquipment Action="X" Type="XF" b1="DARROW" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52470</SeqNum>
    <Name>L138.Decant-Ottawa</Name>
    <LastEdit Timestamp="2026-06-02T11:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02DECANT" b2="138 KV" b3="02D-OTT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DECANT" b2="138 KV" b3="3322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTAWATE" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTAWATE" b2="138 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52490</SeqNum>
    <Name>L230.PossumPoint500-PossumPoint230.L2078</Name>
    <LastEdit Timestamp="2025-01-06T16:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="207892" />
      <ContingencyEquipment Action="S" Type="SD" b1="POSSUMP4" b2="230 KV" b3="2078Z" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="H8T2078" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="L1T2078" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52510</SeqNum>
    <Name>Eastlake.SC1</Name>
    <LastEdit Timestamp="2026-02-10T13:02:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G1SC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTLAKE" b2="18 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q1T" />
      <ContingencyEquipment Action="X" Type="XF" b1="EASTLAKE" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52520</SeqNum>
    <Name>Eastlake.SC2</Name>
    <LastEdit Timestamp="2026-02-10T13:02:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G2SC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTLAKE" b2="18 KV" b3="LOAD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q2T" />
      <ContingencyEquipment Action="X" Type="XF" b1="EASTLAKE" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52530</SeqNum>
    <Name>Eastlake.SC3</Name>
    <LastEdit Timestamp="2026-02-10T13:02:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G3SC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTLAKE" b2="18 KV" b3="LOAD3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q3T" />
      <ContingencyEquipment Action="X" Type="XF" b1="EASTLAKE" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52540</SeqNum>
    <Name>Eastlake.SC4</Name>
    <LastEdit Timestamp="2026-02-10T13:03:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G4SC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTLAKE" b2="18 KV" b3="LOAD410" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q4T" />
      <ContingencyEquipment Action="X" Type="XF" b1="EASTLAKE" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52550</SeqNum>
    <Name>Eastlake.SC5</Name>
    <LastEdit Timestamp="2025-04-14T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="345 KV" b3="B712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="345 KV" b3="B725" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTLAKE" b2="24 KV" b3="LD50" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="24 KV" b3="SC5" />
      <ContingencyEquipment Action="X" Type="XF" b1="EASTLAKE" b2="345 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52560</SeqNum>
    <Name>345/138.Eastlake.TR61</Name>
    <LastEdit Timestamp="2026-06-02T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EASTLAKE" b2="345 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="345 KV" b3="B712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="345 KV" b3="B741" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q61_T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52570</SeqNum>
    <Name>345/138.Eastlake.TR62</Name>
    <LastEdit Timestamp="2026-06-02T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EASTLAKE" b2="345 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="345 KV" b3="B725" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="345 KV" b3="B753" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B97" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52640</SeqNum>
    <Name>345/138.Harding.T3&amp;T4</Name>
    <LastEdit Timestamp="2025-03-14T10:54:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HARDING2" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARDING2" b2="345 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B31" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52650</SeqNum>
    <Name>345/138.Highland.T3 (FE)</Name>
    <LastEdit Timestamp="2025-08-19T10:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="166" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="169" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIGHLAOE" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="95" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52660</SeqNum>
    <Name>L345.HyattCS-Tangy</Name>
    <LastEdit Timestamp="2026-06-04T11:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HYATTCS" b2="345 KV" b3="HYA-TAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="L1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="345 KV" b3="B100" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="345 KV" b3="B174" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52670</SeqNum>
    <Name>L345.Lemoyne-Troy + Troy.U1-4</Name>
    <LastEdit Timestamp="2026-06-05T15:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B12" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEMOYNE2" b2="345 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="G12" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEMOYNE2" b2="345 KV" b3="G2" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEMOYNE2" b2="345 KV" b3="G3" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEMOYNE2" b2="345 KV" b3="G4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="G42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="H22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="H32" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LEMOYNE2" b2="18 KV" b3="UN1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LEMOYNE2" b2="18 KV" b3="UN2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LEMOYNE2" b2="18 KV" b3="UN3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LEMOYNE2" b2="18 KV" b3="UN4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52680</SeqNum>
    <Name>345/138.NorthMedina.TR1</Name>
    <LastEdit Timestamp="2026-06-04T11:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="N_MEDINA" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_MEDINA" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_MEDINA" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_MEDINA" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="X" Type="XF" b1="N_MEDINA" b2="345 KV" b3="TR-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52710</SeqNum>
    <Name>345/138.Tangy.TR3</Name>
    <LastEdit Timestamp="2026-06-03T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="TANGY" b2="138 KV" b3="A192" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="345 KV" b3="B100" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="345 KV" b3="B182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="138 KV" b3="B74" />
      <ContingencyEquipment Action="X" Type="XF" b1="TANGY" b2="345 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52720</SeqNum>
    <Name>345/138.Tangy.TR4</Name>
    <LastEdit Timestamp="2026-06-03T10:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="TANGY" b2="138 KV" b3="A193" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="345 KV" b3="B182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="138 KV" b3="B63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="345 KV" b3="B81" />
      <ContingencyEquipment Action="X" Type="XF" b1="TANGY" b2="345 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52730</SeqNum>
    <Name>345/138.Tangy.TR5</Name>
    <LastEdit Timestamp="2026-06-03T10:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="TANGY" b2="138 KV" b3="A191" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="345 KV" b3="B174" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="138 KV" b3="B189" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="345 KV" b3="B91" />
      <ContingencyEquipment Action="X" Type="XF" b1="TANGY" b2="345 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52740</SeqNum>
    <Name>Troy.U1</Name>
    <LastEdit Timestamp="2026-06-04T11:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LEMOYNE2" b2="345 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="G12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LEMOYNE2" b2="18 KV" b3="UN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52750</SeqNum>
    <Name>Troy.U2</Name>
    <LastEdit Timestamp="2026-06-04T11:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LEMOYNE2" b2="345 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="H22" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LEMOYNE2" b2="18 KV" b3="UN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52760</SeqNum>
    <Name>Troy.U3</Name>
    <LastEdit Timestamp="2026-06-04T11:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LEMOYNE2" b2="345 KV" b3="G3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="H32" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LEMOYNE2" b2="18 KV" b3="UN3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52770</SeqNum>
    <Name>Troy.U4</Name>
    <LastEdit Timestamp="2026-06-04T11:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LEMOYNE2" b2="345 KV" b3="G4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="G42" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LEMOYNE2" b2="18 KV" b3="UN4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52780</SeqNum>
    <Name>L138.Delta-NatureFF-NSSYrk-WrthSTL-Lear-Wauseon</Name>
    <LastEdit Timestamp="2025-09-03T15:57:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELTA" b2="138 KV" b3="B13430" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DELTA" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DELTA" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELTA" b2="138 KV" b3="CS14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELTA" b2="138 KV" b3="CS20" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELTA" b2="138 KV" b3="DEL-NAT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DELTA" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEAR" b2="138 KV" b3="LEA-WOR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEAR" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAUSEON" b2="138 KV" b3="WAU-LEA" />
      <ContingencyEquipment Action="L" Type="LN" b1="NATUREFF" b2="138 KV" b3="NAT-NSS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NATUREFF" b2="138 KV" b3="NFF LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NATUREFF" b2="138 KV" b3="NOVATS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NATUREFF" b2="138 KV" b3="TCREC_LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NSS-YORK" b2="138 KV" b3="LD2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NSS-YORK" b2="138 KV" b3="NSY-TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="WORTHSTL" b2="138 KV" b3="WOR-YOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUSEON" b2="138 KV" b3="B13415" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WORTHSTL" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52790</SeqNum>
    <Name>L138.Dixie-Jackman</Name>
    <LastEdit Timestamp="2025-06-26T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DIXIEFE" b2="138 KV" b3="B13294" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DIXIEFE" b2="138 KV" b3="B55" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKMAN" b2="138 KV" b3="JAC-DIX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKMAN" b2="138 KV" b3="3334" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52800</SeqNum>
    <Name>L138.Hanna-OldForge-EastAkron</Name>
    <LastEdit Timestamp="2025-08-22T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EAKRON" b2="138 KV" b3="43" />
      <ContingencyEquipment Action="L" Type="LN" b1="EAKRON" b2="138 KV" b3="EAK-OLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANNAOE" b2="138 KV" b3="HAN-OLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLDFORGE" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OLDFORGE" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52810</SeqNum>
    <Name>L138.EastAkron-WestRavenna</Name>
    <LastEdit Timestamp="2025-06-25T15:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EAKRON" b2="138 KV" b3="37" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EAKRON" b2="138 KV" b3="A102" />
      <ContingencyEquipment Action="L" Type="LN" b1="WRAVENNA" b2="138 KV" b3="WRA-EAK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WRAVENNA" b2="138 KV" b3="B15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52820</SeqNum>
    <Name>L138.Eber-JohnsonControl-Swanton</Name>
    <LastEdit Timestamp="2025-07-28T11:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02EBER" b2="138 KV" b3="02E-02JO" />
      <ContingencyEquipment Action="L" Type="LN" b1="02EBER" b2="138 KV" b3="02E-02SW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02EBER" b2="138 KV" b3="B13435" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02EBER" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02JOHNCT" b2="138 KV" b3="LDJC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02JOHNCT" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02SWANTN" b2="138 KV" b3="B13425" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52830</SeqNum>
    <Name>L138.Evergreen-Highland.1</Name>
    <LastEdit Timestamp="2026-06-04T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="EVERGFE" b2="138 KV" b3="A73" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERGFE" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLAOE" b2="138 KV" b3="HIG-EVE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="111" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="82" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52840</SeqNum>
    <Name>L138.Evergreen-Highland.2</Name>
    <LastEdit Timestamp="2026-06-04T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="EVERGFE" b2="138 KV" b3="A85" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERGFE" b2="138 KV" b3="B25" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLAOE" b2="138 KV" b3="HIG-EVE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="111" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="92" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52850</SeqNum>
    <Name>L138.Evergreen-Bane-Burton-RTIMetals-Highland</Name>
    <LastEdit Timestamp="2026-04-29T17:43:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BANEFE" b2="138 KV" b3="BAN-EVER" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BANEFE" b2="138 KV" b3="EMRLDCTY" />
      <ContingencyEquipment Action="L" Type="LN" b1="BANEFE" b2="138 KV" b3="BAN-BURT" />
      <ContingencyEquipment Action="L" Type="LN" b1="REACTMET" b2="138 KV" b3="REA-BUR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BURTONOE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EVERGFE" b2="138 KV" b3="A92" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERGFE" b2="138 KV" b3="B93" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="40" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLAOE" b2="138 KV" b3="HIG-REA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REACTMET" b2="138 KV" b3="LDRMI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52870</SeqNum>
    <Name>L138.Evergreen-NilesPlant</Name>
    <LastEdit Timestamp="2025-03-24T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="EVERGFE" b2="138 KV" b3="A79" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERGFE" b2="138 KV" b3="B24" />
      <ContingencyEquipment Action="L" Type="LN" b1="NILES" b2="138 KV" b3="NIL-EVE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NILES" b2="138 KV" b3="B11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52880</SeqNum>
    <Name>L138.FordLorain-02Brwell-NewDeparture</Name>
    <LastEdit Timestamp="2026-06-04T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FORDFE" b2="138 KV" b3="FOR-02B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NDEPT" b2="138 KV" b3="NDE-02B1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02BRWELL" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORDFE" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORDFE" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NDEPT" b2="138 KV" b3="17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NDEPT" b2="138 KV" b3="2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52890</SeqNum>
    <Name>L138.Galion-Leaside</Name>
    <LastEdit Timestamp="2026-06-04T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="53" />
      <ContingencyEquipment Action="L" Type="LN" b1="GALION" b2="138 KV" b3="GAL-LES1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LESIDE" b2="138 KV" b3="36" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52900</SeqNum>
    <Name>L138.Galion-MarionEthonal-Roberts</Name>
    <LastEdit Timestamp="2026-06-04T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="59" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="60" />
      <ContingencyEquipment Action="L" Type="LN" b1="GALION" b2="138 KV" b3="GAL-MAR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROBERTOE" b2="138 KV" b3="ROB-MAR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARIONET" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTOE" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROBERTOE" b2="138 KV" b3="D50" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52920</SeqNum>
    <Name>138/69.Galion.T1</Name>
    <LastEdit Timestamp="2025-09-02T10:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="168" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="54" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="B57" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="69 KV" b3="B9" />
      <ContingencyEquipment Action="X" Type="XF" b1="GALION" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52930</SeqNum>
    <Name>138/69.Galion.T2</Name>
    <LastEdit Timestamp="2025-08-25T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="165" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="58" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="69 KV" b3="B133" />
      <ContingencyEquipment Action="X" Type="XF" b1="GALION" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52940</SeqNum>
    <Name>L138.Gates-Murray-Johnson</Name>
    <LastEdit Timestamp="2024-10-31T08:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GATESOE" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GATESOE" b2="138 KV" b3="A 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="GATESOE" b2="138 KV" b3="GAT-MUR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSOFE" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="JOHNSOFE" b2="138 KV" b3="A23" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSOFE" b2="138 KV" b3="JOH-MUR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MURRAYOE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MURRAYOE" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52950</SeqNum>
    <Name>L138.Greenfield-NewDeparture</Name>
    <LastEdit Timestamp="2025-06-25T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENFOE" b2="138 KV" b3="A122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENFOE" b2="138 KV" b3="B40" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENFOE" b2="138 KV" b3="GRE-NDE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NDEPT" b2="138 KV" b3="17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NDEPT" b2="138 KV" b3="20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52960</SeqNum>
    <Name>L138.Gilchrist-EastAkron</Name>
    <LastEdit Timestamp="2025-06-25T15:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EAKRON" b2="138 KV" b3="46" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EAKRON" b2="138 KV" b3="A134" />
      <ContingencyEquipment Action="L" Type="LN" b1="EAKRON" b2="138 KV" b3="EAK-GLC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCRSTOE" b2="138 KV" b3="B31" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52970</SeqNum>
    <Name>L138.Gilchrist-Lakemore</Name>
    <LastEdit Timestamp="2026-06-04T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCRSTOE" b2="138 KV" b3="B32" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEMORE" b2="138 KV" b3="LAK-GLC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEMORE" b2="138 KV" b3="B51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEMORE" b2="138 KV" b3="B54" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52980</SeqNum>
    <Name>L138.Magellan-Tod-Highland</Name>
    <LastEdit Timestamp="2025-07-14T14:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLAOE" b2="138 KV" b3="HIG-TOD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGELLAN" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGELLAN" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAGELLAN" b2="138 KV" b3="MAG-TOD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOD" b2="138 KV" b3="12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TOD" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>52990</SeqNum>
    <Name>L138.GMPowerTrain-Smuckers-Jackman</Name>
    <LastEdit Timestamp="2025-11-12T10:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GM_PWR" b2="138 KV" b3="B13295" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKMAN" b2="138 KV" b3="3329" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMUCKERS" b2="138 KV" b3="CS13158" />
      <ContingencyEquipment Action="L" Type="LN" b1="GM_PWR" b2="138 KV" b3="GMP-SMU" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKMAN" b2="138 KV" b3="JAC-SMU1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SMUCKERS" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53010</SeqNum>
    <Name>L138.GM-Richland#1</Name>
    <LastEdit Timestamp="2025-11-04T16:30:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02GMC" b2="138 KV" b3="13272" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02GMC" b2="138 KV" b3="13278" />
      <ContingencyEquipment Action="L" Type="LN" b1="RICHLND" b2="138 KV" b3="RIC-02G1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02GMC" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="138 KV" b3="B13242" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53020</SeqNum>
    <Name>L138.GM-Richland#2</Name>
    <LastEdit Timestamp="2025-11-04T16:31:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02GMC" b2="138 KV" b3="13270" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02GMC" b2="138 KV" b3="13271" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02GMC" b2="138 KV" b3="13278" />
      <ContingencyEquipment Action="L" Type="LN" b1="RICHLND" b2="138 KV" b3="RIC-02G2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02GMC" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02GMC" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="138 KV" b3="B13243" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53030</SeqNum>
    <Name>L138.Greenfield-NASA</Name>
    <LastEdit Timestamp="2026-06-04T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENFOE" b2="138 KV" b3="A128" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENFOE" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENFOE" b2="138 KV" b3="GRE-NAS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NASA" b2="138 KV" b3="1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53040</SeqNum>
    <Name>L138.Greenfield-Visteon</Name>
    <LastEdit Timestamp="2024-05-06T15:29:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENFOE" b2="138 KV" b3="A338" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENFOE" b2="138 KV" b3="B335" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENFOE" b2="138 KV" b3="GRE-VIS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VISTEON" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VISTEON" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VISTEON" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VISTEON" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53050</SeqNum>
    <Name>L138.Greenfield-Lakeview</Name>
    <LastEdit Timestamp="2026-06-04T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENFOE" b2="138 KV" b3="A240" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENFOE" b2="138 KV" b3="B242" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKVEW" b2="138 KV" b3="LAK-GRE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKVEW" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKVEW" b2="138 KV" b3="96" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53060</SeqNum>
    <Name>L138.Hanna-Newton Falls</Name>
    <LastEdit Timestamp="2025-08-22T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANNAOE" b2="138 KV" b3="HAN-NEW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTONFA" b2="138 KV" b3="27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTONFA" b2="138 KV" b3="32" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53070</SeqNum>
    <Name>L138.Hanna-Shalersville</Name>
    <LastEdit Timestamp="2024-05-17T09:49:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANNAOE" b2="138 KV" b3="HAN-SHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHALERS" b2="138 KV" b3="B26" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHALERS" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53080</SeqNum>
    <Name>L138.Aetna-West Akron</Name>
    <LastEdit Timestamp="2025-07-15T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AETNA" b2="138 KV" b3="B169" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AETNA" b2="138 KV" b3="B171" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAKRON" b2="138 KV" b3="WAK-AET1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKRON" b2="138 KV" b3="B10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53090</SeqNum>
    <Name>L138.Highland-Salt Springs</Name>
    <LastEdit Timestamp="2024-05-08T16:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="24" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLAOE" b2="138 KV" b3="HIG-SAL1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SALTSPRG" b2="138 KV" b3="A38" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTSPRG" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53100</SeqNum>
    <Name>L138.Highland-Mahoningside</Name>
    <LastEdit Timestamp="2025-08-22T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="158" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="166" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLAOE" b2="138 KV" b3="HIG-MAH1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAHONIFE" b2="138 KV" b3="B67" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53110</SeqNum>
    <Name>L138.Hoytdale-Cranberry</Name>
    <LastEdit Timestamp="2024-05-08T16:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="30" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRANBERY" b2="138 KV" b3="CRA-HOY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53120</SeqNum>
    <Name>L138.Hoytdale-KoppelSt.Z-109</Name>
    <LastEdit Timestamp="2025-01-29T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOYTDAL2" b2="138 KV" b3="KOPPEL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53140</SeqNum>
    <Name>L138.Chamberlin-HudsonMuni</Name>
    <LastEdit Timestamp="2024-10-03T15:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B59" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B65" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAMBROE" b2="138 KV" b3="CHA-HUDM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDMUN" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDMUN" b2="138 KV" b3="2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53170</SeqNum>
    <Name>L138.Ivanhoe-Mahoning Side</Name>
    <LastEdit Timestamp="2025-08-22T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IVANHOOE" b2="138 KV" b3="90" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVANHOOE" b2="138 KV" b3="93" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVANHOOE" b2="138 KV" b3="B107" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAHONIFE" b2="138 KV" b3="MAH-IVA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAHONIFE" b2="138 KV" b3="B63" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53180</SeqNum>
    <Name>L138.Ivanhoe-Packard</Name>
    <LastEdit Timestamp="2024-05-09T08:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IVANHOOE" b2="138 KV" b3="9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVANHOOE" b2="138 KV" b3="90" />
      <ContingencyEquipment Action="L" Type="LN" b1="IVANHOOE" b2="138 KV" b3="IVA-PAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PACKRDOE" b2="138 KV" b3="10" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PACKRDOE" b2="138 KV" b3="A 8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53190</SeqNum>
    <Name>L138.Jackman-Vulcan</Name>
    <LastEdit Timestamp="2025-05-20T11:10:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKMAN" b2="138 KV" b3="3140" />
      <ContingencyEquipment Action="L" Type="LN" b1="VULCAN" b2="138 KV" b3="VUL-JAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VULCAN" b2="138 KV" b3="B13393" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53200</SeqNum>
    <Name>L138.Jackman-Westgate</Name>
    <LastEdit Timestamp="2025-08-06T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02WESTGT" b2="138 KV" b3="02W-JAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02WESTGT" b2="138 KV" b3="B13315" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKMAN" b2="138 KV" b3="B13331" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53230</SeqNum>
    <Name>L138.Crissinger-Roberts</Name>
    <LastEdit Timestamp="2025-07-17T16:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISS" b2="138 KV" b3="B118" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRISS" b2="138 KV" b3="CRI-ROBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTOE" b2="138 KV" b3="B12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53240</SeqNum>
    <Name>L138.Kirby-SouthScito-Tangy</Name>
    <LastEdit Timestamp="2024-11-15T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRBY" b2="138 KV" b3="12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRBY" b2="138 KV" b3="18" />
      <ContingencyEquipment Action="L" Type="LN" b1="SSCIOTO" b2="138 KV" b3="KIRL-SSC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SSCIOTO" b2="138 KV" b3="LD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SSCIOTO" b2="138 KV" b3="SSC-TAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TANGY" b2="138 KV" b3="A110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="138 KV" b3="B54" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53250</SeqNum>
    <Name>L138.Kirby-13829REA-BlueJacket</Name>
    <LastEdit Timestamp="2025-07-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="13829REA" b2="138 KV" b3="138-BLU" />
      <ContingencyEquipment Action="L" Type="LN" b1="13829REA" b2="138 KV" b3="138-KIR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="13829REA" b2="138 KV" b3="ELOGAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEJACK" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRBY" b2="138 KV" b3="12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRBY" b2="138 KV" b3="5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53260</SeqNum>
    <Name>L138.Lemoyne-WestFremont</Name>
    <LastEdit Timestamp="2025-02-28T12:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="138 KV" b3="13215" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEMOYNE2" b2="138 KV" b3="LEM-WFR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53270</SeqNum>
    <Name>138/69.Avery.TR1</Name>
    <LastEdit Timestamp="2025-08-06T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AVERY" b2="138 KV" b3="B29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVERY" b2="138 KV" b3="B36" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVERY" b2="69 KV" b3="B86" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="AVERY" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="AVERY" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="X" Type="XF" b1="AVERY" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53290</SeqNum>
    <Name>L138.Richland-Ayersville</Name>
    <LastEdit Timestamp="2025-11-04T16:32:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="02AYERSV" b2="138 KV" b3="A544" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02AYERSV" b2="138 KV" b3="CS13187" />
      <ContingencyEquipment Action="L" Type="LN" b1="RICHLND" b2="138 KV" b3="RIC-02A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02AYERSV" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="138 KV" b3="B13235" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53310</SeqNum>
    <Name>L138.Bayshore-Ironville</Name>
    <LastEdit Timestamp="2025-08-06T14:45:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="138 KV" b3="B13253" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYSHOR2" b2="138 KV" b3="BAY-IRO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONVILL" b2="138 KV" b3="B13208" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53330</SeqNum>
    <Name>L138.Bayshore-TousSaint-Ottawa</Name>
    <LastEdit Timestamp="2025-08-06T14:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02TOUSNT" b2="138 KV" b3="02T-OTT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYSHOR2" b2="138 KV" b3="BAY-02T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02TOUSNT" b2="138 KV" b3="CS13010" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="138 KV" b3="B13105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTAWATE" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTAWATE" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53340</SeqNum>
    <Name>L138.Boardman-Nevada-Sammis</Name>
    <LastEdit Timestamp="2024-05-07T15:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BOARDMAN" b2="138 KV" b3="A146" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOARDMAN" b2="138 KV" b3="B85" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOARDMAN" b2="138 KV" b3="BOA-NEV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEVADAOE" b2="138 KV" b3="B144" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEVADAOE" b2="138 KV" b3="B148" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEVADAOE" b2="138 KV" b3="NEV-SAMM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEVADAOE" b2="138 KV" b3="TR1 LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEVADAOE" b2="138 KV" b3="TR3 LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="138 KV" b3="B9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53350</SeqNum>
    <Name>138/69.Boardman.TR2</Name>
    <LastEdit Timestamp="2025-03-24T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BOARDMAN" b2="138 KV" b3="A165" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOARDMAN" b2="69 KV" b3="B52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOARDMAN" b2="138 KV" b3="B90" />
      <ContingencyEquipment Action="X" Type="XF" b1="BOARDMAN" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53360</SeqNum>
    <Name>138/69.Bluebell.TR4</Name>
    <LastEdit Timestamp="2024-05-07T14:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BLUEBELL" b2="138 KV" b3="A124" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEBELL" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEBELL" b2="69 KV" b3="B80" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUEBELL" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53370</SeqNum>
    <Name>138/69.Bluebell.TR5</Name>
    <LastEdit Timestamp="2024-05-07T15:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEBELL" b2="69 KV" b3="B182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEBELL" b2="138 KV" b3="B187" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUEBELL" b2="138 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53390</SeqNum>
    <Name>138/69.Brookside.TR3</Name>
    <LastEdit Timestamp="2025-06-23T15:29:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKSID" b2="69 KV" b3="A215" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKSID" b2="138 KV" b3="A93" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSID" b2="138 KV" b3="B206" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSID" b2="69 KV" b3="B213" />
      <ContingencyEquipment Action="X" Type="XF" b1="BROOKSID" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53400</SeqNum>
    <Name>138/69.Brookside.TR4</Name>
    <LastEdit Timestamp="2025-06-23T15:30:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKSID" b2="138 KV" b3="A130" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKSID" b2="69 KV" b3="A158" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSID" b2="138 KV" b3="B128" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSID" b2="69 KV" b3="B156" />
      <ContingencyEquipment Action="X" Type="XF" b1="BROOKSID" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53410</SeqNum>
    <Name>138/69.Brookside.TR5</Name>
    <LastEdit Timestamp="2025-06-23T15:30:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKSID" b2="69 KV" b3="A181" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKSID" b2="138 KV" b3="A199" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSID" b2="69 KV" b3="B179" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSID" b2="138 KV" b3="B200" />
      <ContingencyEquipment Action="X" Type="XF" b1="BROOKSID" b2="138 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53450</SeqNum>
    <Name>L138.Cardington-Galion</Name>
    <LastEdit Timestamp="2025-09-02T10:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="02CARDNT" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02CARDNT" b2="69 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="GALION" b2="138 KV" b3="GAL-02C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="B56" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="B57" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53460</SeqNum>
    <Name>138/69.Cedar Street.TR1</Name>
    <LastEdit Timestamp="2024-05-08T16:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAROE" b2="138 KV" b3="B252" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAROE" b2="138 KV" b3="B258" />
      <ContingencyEquipment Action="X" Type="XF" b1="CEDAROE" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53470</SeqNum>
    <Name>L138.Chrysler-ShelbyFS-Walgreen-Calphalon-Maclean</Name>
    <LastEdit Timestamp="2025-02-26T10:38:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CALPHALN" b2="138 KV" b3="02W-CAL" />
      <ContingencyEquipment Action="L" Type="LN" b1="02WALBRD" b2="138 KV" b3="MAC-02W" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02WALBRD" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02WALBRD" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TMT_WARE" b2="138 KV" b3="TMT-CAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CALPHALN" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRYSLE2" b2="138 KV" b3="13292" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHRYSLE2" b2="138 KV" b3="CHR-SHEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACLEAN" b2="138 KV" b3="B13204" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHELBYFS" b2="138 KV" b3="SHE-WALG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHELBYFS" b2="138 KV" b3="SHELBYLD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHELBYFS" b2="138 KV" b3="TRACYRLD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TMT_WARE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALGRN" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALGRN" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="WALGRN" b2="138 KV" b3="WAL-TMT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53480</SeqNum>
    <Name>138/69.Cloverdale.TR4</Name>
    <LastEdit Timestamp="2025-11-17T16:04:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLOVEROE" b2="138 KV" b3="A194" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="138 KV" b3="B191" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="69 KV" b3="B263CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVEROE" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53490</SeqNum>
    <Name>138/69.Cloverdale.TR6</Name>
    <LastEdit Timestamp="2025-11-17T16:05:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLOVEROE" b2="138 KV" b3="A257" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="138 KV" b3="B254" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="69 KV" b3="B259CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVEROE" b2="138 KV" b3="TR6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53500</SeqNum>
    <Name>138/69.Clark.TR1</Name>
    <LastEdit Timestamp="2024-05-07T15:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKOE" b2="138 KV" b3="B106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKOE" b2="69 KV" b3="B61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKOE" b2="138 KV" b3="B72" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLARKOE" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53510</SeqNum>
    <Name>138/69.Clark.TR2</Name>
    <LastEdit Timestamp="2024-05-07T15:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKOE" b2="69 KV" b3="B118" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKOE" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKOE" b2="138 KV" b3="B65" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLARKOE" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53530</SeqNum>
    <Name>138/69.Dixie.TR6</Name>
    <LastEdit Timestamp="2025-07-15T12:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DIXIEFE" b2="138 KV" b3="B13293" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DIXIEFE" b2="69 KV" b3="B6900" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DIXIEFE" b2="138 KV" b3="B70" />
      <ContingencyEquipment Action="X" Type="XF" b1="DIXIEFE" b2="138 KV" b3="TR6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53540</SeqNum>
    <Name>L138.BlackRiver-RepArc-RepVine</Name>
    <LastEdit Timestamp="2024-05-07T15:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKRIV" b2="138 KV" b3="BLA-REPA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REPVINE" b2="138 KV" b3="14" />
      <ContingencyEquipment Action="L" Type="LN" b1="REP_ARC" b2="138 KV" b3="REP-REPV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53570</SeqNum>
    <Name>138/69.EastSpringfield.TR4</Name>
    <LastEdit Timestamp="2025-06-24T13:10:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ESPROHED" b2="69 KV" b3="A136" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ESPROHED" b2="138 KV" b3="A138" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESPROHED" b2="69 KV" b3="B58" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESPROHED" b2="138 KV" b3="B63" />
      <ContingencyEquipment Action="X" Type="XF" b1="ESPROHED" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53580</SeqNum>
    <Name>138/69.EastSpringfield.TR5</Name>
    <LastEdit Timestamp="2025-06-24T13:11:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ESPROHED" b2="138 KV" b3="A220" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ESPROHED" b2="69 KV" b3="A241" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESPROHED" b2="138 KV" b3="B218" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESPROHED" b2="69 KV" b3="B225" />
      <ContingencyEquipment Action="X" Type="XF" b1="ESPROHED" b2="138 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53590</SeqNum>
    <Name>L138.Evergreen-Reinforc-OHStr-Frankln-Brdg-Ivanhoe</Name>
    <LastEdit Timestamp="2025-07-25T16:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRIDGEOE" b2="138 KV" b3="A 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEOE" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIDGEOE" b2="138 KV" b3="BRI-IVA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRNKLNOE" b2="138 KV" b3="FRN-BRI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRIDGEOE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRIDGEOE" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EVERGFE" b2="138 KV" b3="A66" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERGFE" b2="138 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRNKLNOE" b2="138 KV" b3="12" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRNKLNOE" b2="138 KV" b3="FRN-OHI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRNKLNOE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVANHOOE" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVANHOOE" b2="138 KV" b3="93" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OHIO_STR" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EVERGFE" b2="138 KV" b3="EVE-REI" />
      <ContingencyEquipment Action="L" Type="LN" b1="REINFORC" b2="138 KV" b3="OHI-REI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REINFORC" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53600</SeqNum>
    <Name>138/69.Gilchrist.TR1</Name>
    <LastEdit Timestamp="2024-05-07T15:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCRSTOE" b2="138 KV" b3="B31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCRSTOE" b2="138 KV" b3="B32" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GLCRSTOE" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GLCRSTOE" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCRSTOE" b2="138 KV" b3="CS131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCRSTOE" b2="138 KV" b3="CS133" />
      <ContingencyEquipment Action="L" Type="LN" b1="EAKRON" b2="138 KV" b3="EAK-GLC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEMORE" b2="138 KV" b3="LAK-GLC1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLCRSTOE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLCRSTOE" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53620</SeqNum>
    <Name>138/69.Greenfield.TR5</Name>
    <LastEdit Timestamp="2025-03-24T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENFOE" b2="69 KV" b3="74" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENFOE" b2="138 KV" b3="A70" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENFOE" b2="138 KV" b3="B68" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENFOE" b2="138 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53630</SeqNum>
    <Name>138/69.Greenfield.TR7</Name>
    <LastEdit Timestamp="2025-06-23T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENFOE" b2="69 KV" b3="331" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENFOE" b2="138 KV" b3="A339" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENFOE" b2="138 KV" b3="B327" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENFOE" b2="138 KV" b3="TR7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53640</SeqNum>
    <Name>138/69.Johnson.TR5</Name>
    <LastEdit Timestamp="2025-06-23T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSOFE" b2="138 KV" b3="122" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="JOHNSOFE" b2="138 KV" b3="A116" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSOFE" b2="69 KV" b3="B123" />
      <ContingencyEquipment Action="X" Type="XF" b1="JOHNSOFE" b2="138 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53650</SeqNum>
    <Name>138/69.Johnson.TR7</Name>
    <LastEdit Timestamp="2025-06-23T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSOFE" b2="138 KV" b3="203" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="JOHNSOFE" b2="138 KV" b3="A210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSOFE" b2="69 KV" b3="B177" />
      <ContingencyEquipment Action="X" Type="XF" b1="JOHNSOFE" b2="138 KV" b3="TR7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53660</SeqNum>
    <Name>138/69.Kirby.TR1</Name>
    <LastEdit Timestamp="2024-05-07T15:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRBY" b2="138 KV" b3="24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRBY" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="X" Type="XF" b1="KIRBY" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53670</SeqNum>
    <Name>138/69.Knox.TR1</Name>
    <LastEdit Timestamp="2026-05-27T13:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOX" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOX" b2="69 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOX" b2="138 KV" b3="B81" />
      <ContingencyEquipment Action="X" Type="XF" b1="KNOX" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53680</SeqNum>
    <Name>138/69.Knox.TR2</Name>
    <LastEdit Timestamp="2026-06-08T15:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOX" b2="138 KV" b3="B53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOX" b2="138 KV" b3="B57" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOX" b2="69 KV" b3="B62" />
      <ContingencyEquipment Action="X" Type="XF" b1="KNOX" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53690</SeqNum>
    <Name>L138.LincolnPark-Elwood-Masury</Name>
    <LastEdit Timestamp="2024-11-15T11:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02ELWOOD" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02ELWOOD" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELWODOE" b2="138 KV" b3="ELW-02E1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02ELWOOD" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02ELWOOD" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELWODOE" b2="138 KV" b3="ELW-LNC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELWODOE" b2="138 KV" b3="ELW-MAS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LNCOLNPK" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LNCOLNPK" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MASURY" b2="138 KV" b3="A119" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASURY" b2="138 KV" b3="B101" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53700</SeqNum>
    <Name>L138.Lakeview-Ottawa</Name>
    <LastEdit Timestamp="2024-05-09T11:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKVEW" b2="138 KV" b3="145" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKVEW" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKVEW" b2="138 KV" b3="LAK-OTT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTAWATE" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTAWATE" b2="138 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53710</SeqNum>
    <Name>L138.Lockwood-Richland</Name>
    <LastEdit Timestamp="2024-12-10T16:09:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKWOOD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKWOOD" b2="138 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKWOOD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOCKWOOD" b2="138 KV" b3="BBYP" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LOCKWOOD" b2="138 KV" b3="CAPA" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOCKWOOD" b2="138 KV" b3="LOC-RIC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="138 KV" b3="B13294" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53730</SeqNum>
    <Name>138/69.London.TR3</Name>
    <LastEdit Timestamp="2026-06-05T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONDONOE" b2="138 KV" b3="A131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONDONOE" b2="138 KV" b3="B133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONDONOE" b2="69 KV" b3="B138" />
      <ContingencyEquipment Action="X" Type="XF" b1="LONDONOE" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53740</SeqNum>
    <Name>138/69.London.TR4</Name>
    <LastEdit Timestamp="2025-06-23T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONDONOE" b2="138 KV" b3="A179" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONDONOE" b2="138 KV" b3="B188" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONDONOE" b2="69 KV" b3="B189" />
      <ContingencyEquipment Action="X" Type="XF" b1="LONDONOE" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53750</SeqNum>
    <Name>L138.Lowellville-Lincoln Park</Name>
    <LastEdit Timestamp="2025-03-17T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LNCOLNPK" b2="138 KV" b3="67" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LNCOLNPK" b2="138 KV" b3="68" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOWELL" b2="138 KV" b3="LOW-LNC1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOWELL" b2="138 KV" b3="A11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWELL" b2="138 KV" b3="B91" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53760</SeqNum>
    <Name>138/69.Lowellsville.TB8</Name>
    <LastEdit Timestamp="2025-06-23T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOWELL" b2="138 KV" b3="A47" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWELL" b2="69 KV" b3="B205" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWELL" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOWELL" b2="138 KV" b3="TB8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53770</SeqNum>
    <Name>138/69.Maclean.TR1</Name>
    <LastEdit Timestamp="2026-06-05T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MACLEAN" b2="138 KV" b3="B13202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACLEAN" b2="138 KV" b3="B13203" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACLEAN" b2="138 KV" b3="B13204" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACLEAN" b2="69 KV" b3="B6973" />
      <ContingencyEquipment Action="X" Type="XF" b1="MACLEAN" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53780</SeqNum>
    <Name>138/69.Maclean.TR2</Name>
    <LastEdit Timestamp="2024-05-08T16:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MACLEAN" b2="138 KV" b3="B13201" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACLEAN" b2="138 KV" b3="B13203" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACLEAN" b2="69 KV" b3="B6977" />
      <ContingencyEquipment Action="X" Type="XF" b1="MACLEAN" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53800</SeqNum>
    <Name>138/69.Maple.TR1</Name>
    <LastEdit Timestamp="2025-02-21T12:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLEOE" b2="69 KV" b3="B114" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLEOE" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLEOE" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="X" Type="XF" b1="MAPLEOE" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53810</SeqNum>
    <Name>138/69.Maple.TR2</Name>
    <LastEdit Timestamp="2025-02-21T14:51:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLEOE" b2="69 KV" b3="B106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLEOE" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLEOE" b2="138 KV" b3="B50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLEOE" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MAPLEOE" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MAPLEOE" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53820</SeqNum>
    <Name>L138.Maple-Jackson-Cranberry</Name>
    <LastEdit Timestamp="2024-05-09T15:25:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRANBERY" b2="138 KV" b3="CRA-JAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSNOE" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAPLEOE" b2="138 KV" b3="MAP-JAC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JACKSNOE" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLEOE" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLEOE" b2="138 KV" b3="B22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53830</SeqNum>
    <Name>L138.Masury-Maysville + 138/69.Maysville.T1</Name>
    <LastEdit Timestamp="2025-06-25T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MASURY" b2="138 KV" b3="A124" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASURY" b2="138 KV" b3="B85" />
      <ContingencyEquipment Action="L" Type="LN" b1="MASURY" b2="138 KV" b3="MAS-MAY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYSVILL" b2="69 KV" b3="B10" />
      <ContingencyEquipment Action="X" Type="XF" b1="MAYSVILL" b2="138 KV" b3="TR 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53840</SeqNum>
    <Name>L138.Masury-Shenango</Name>
    <LastEdit Timestamp="2024-05-09T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MASURY" b2="138 KV" b3="A59" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASURY" b2="138 KV" b3="B87" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHENANGO" b2="138 KV" b3="SHE-MAS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53850</SeqNum>
    <Name>L138.Masury-SaltSprings</Name>
    <LastEdit Timestamp="2025-06-25T15:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MASURY" b2="138 KV" b3="A127" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASURY" b2="138 KV" b3="B118" />
      <ContingencyEquipment Action="L" Type="LN" b1="SALTSPRG" b2="138 KV" b3="SAL-MAS1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SALTSPRG" b2="138 KV" b3="A172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTSPRG" b2="138 KV" b3="B170" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53860</SeqNum>
    <Name>138/69.Masury.TR2</Name>
    <LastEdit Timestamp="2026-06-08T15:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MASURY" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASURY" b2="69 KV" b3="B3" />
      <ContingencyEquipment Action="X" Type="XF" b1="MASURY" b2="138 KV" b3="TB2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53870</SeqNum>
    <Name>138/69.Masury.TB4</Name>
    <LastEdit Timestamp="2026-06-05T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MASURY" b2="138 KV" b3="B286" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASURY" b2="69 KV" b3="B291" />
      <ContingencyEquipment Action="X" Type="XF" b1="MASURY" b2="138 KV" b3="TB4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53890</SeqNum>
    <Name>138/69.McDowell.TR3</Name>
    <LastEdit Timestamp="2025-05-12T11:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCDOWLOE" b2="69 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCDOWLOE" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="X" Type="XF" b1="MCDOWLOE" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53900</SeqNum>
    <Name>L138.Midway-Napoleon</Name>
    <LastEdit Timestamp="2024-05-09T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13304" />
      <ContingencyEquipment Action="L" Type="LN" b1="NAPLNN" b2="138 KV" b3="NAP-MID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAPLNN" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAPLNN" b2="138 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53910</SeqNum>
    <Name>L138.Midway-Waterville-JohnsManville-LevisPark</Name>
    <LastEdit Timestamp="2025-04-02T15:19:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MANIVL" b2="138 KV" b3="02O-MAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02OILEVS" b2="138 KV" b3="B13336" />
      <ContingencyEquipment Action="L" Type="LN" b1="02WATERV" b2="138 KV" b3="02W-MID1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02WATERV" b2="138 KV" b3="CI13130" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02WATERV" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02WATERV" b2="138 KV" b3="WAT-MAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANIVL" b2="138 KV" b3="13117" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANIVL" b2="138 KV" b3="13134" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MANIVL" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MANIVL" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13300" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53920</SeqNum>
    <Name>138/69.Midway.TR1</Name>
    <LastEdit Timestamp="2024-05-08T16:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13302" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13303" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13304" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13308" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="69 KV" b3="B6878" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="CS43" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDWAYTE" b2="138 KV" b3="TR 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53930</SeqNum>
    <Name>138/69.Midway.TR2</Name>
    <LastEdit Timestamp="2024-05-08T16:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13211" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13300" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13303" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13305" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="69 KV" b3="B6879" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="CS51" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDWAYTE" b2="138 KV" b3="TR 2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53940</SeqNum>
    <Name>L138.MidwayTE-StLukes-Dana-Hawthorn-Angola</Name>
    <LastEdit Timestamp="2024-11-15T11:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02ANGOLA" b2="138 KV" b3="02A-HAW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02ANGOLA" b2="138 KV" b3="B13473" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02ANGOLA" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANA" b2="138 KV" b3="3077CS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DANA" b2="138 KV" b3="DAN-STL" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAWTANGL" b2="138 KV" b3="HAW-DAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DANA" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAWTANGL" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAWTANGL" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13308" />
      <ContingencyEquipment Action="L" Type="LN" b1="ST_LUK" b2="138 KV" b3="MID-STL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ST_LUK" b2="138 KV" b3="CS3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ST_LUK" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53960</SeqNum>
    <Name>L138.Richland-Wauseon</Name>
    <LastEdit Timestamp="2025-11-07T15:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="138 KV" b3="B13291" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUSEON" b2="138 KV" b3="B41" />
      <ContingencyEquipment Action="L" Type="LN" b1="RICHLND" b2="138 KV" b3="RIC-WAUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53970</SeqNum>
    <Name>L138.NewCastle-Hoytdale.Z-104</Name>
    <LastEdit Timestamp="2025-01-29T15:24:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="18" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWCASOE" b2="138 KV" b3="NEW-HOY2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NEWCASOE" b2="138 KV" b3="A152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASOE" b2="138 KV" b3="B150" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53980</SeqNum>
    <Name>L138.NewCastle-Hoytdale.Z-110</Name>
    <LastEdit Timestamp="2025-01-29T15:29:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="22" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWCASOE" b2="138 KV" b3="NEW-HOY1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NEWCASOE" b2="138 KV" b3="A14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASOE" b2="138 KV" b3="B12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>53990</SeqNum>
    <Name>138/69.New Castle.TR7</Name>
    <LastEdit Timestamp="2024-05-08T16:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASOE" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASOE" b2="69 KV" b3="B32" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWCASOE" b2="138 KV" b3="TR7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54000</SeqNum>
    <Name>138/69.New Castle.TR8</Name>
    <LastEdit Timestamp="2026-06-05T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASOE" b2="69 KV" b3="B172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASOE" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWCASOE" b2="138 KV" b3="TR8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54010</SeqNum>
    <Name>NewCastle.U5</Name>
    <LastEdit Timestamp="2024-05-09T14:59:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASOE" b2="138 KV" b3="B24" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWCASOE" b2="16 KV" b3="G5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWCASOE" b2="16 KV" b3="LD5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASOE" b2="16 KV" b3="NH50" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWCASOE" b2="138 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54030</SeqNum>
    <Name>L138.NewtonFalls-GMLordsTown</Name>
    <LastEdit Timestamp="2025-06-25T15:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GMWAROE" b2="138 KV" b3="A 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GMWAROE" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWTONFA" b2="138 KV" b3="NEW-GMW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTONFA" b2="138 KV" b3="27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTONFA" b2="138 KV" b3="29" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54040</SeqNum>
    <Name>138/69.NewtonFalls.TR1 &amp; TR2</Name>
    <LastEdit Timestamp="2025-03-24T15:58:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTONFA" b2="138 KV" b3="32" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NEWTONFA" b2="138 KV" b3="A112" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWTONFA" b2="23 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTONFA" b2="69 KV" b3="B41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTONFA" b2="23 KV" b3="J" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWTONFA" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWTONFA" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54050</SeqNum>
    <Name>138/69.NewtonFalls.TR3</Name>
    <LastEdit Timestamp="2025-03-24T11:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTONFA" b2="138 KV" b3="29" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NEWTONFA" b2="138 KV" b3="A112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTONFA" b2="69 KV" b3="B44" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWTONFA" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54060</SeqNum>
    <Name>L138.Bluebell-BerlinLake</Name>
    <LastEdit Timestamp="2024-05-08T16:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERLNLK" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERLNLK" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEBELL" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERLNLK" b2="138 KV" b3="BER-BLUE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54070</SeqNum>
    <Name>L138.NilesPlant-MCDonaldSteel-NilesCentral</Name>
    <LastEdit Timestamp="2025-06-25T15:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CNTRALOE" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CNTRALOE" b2="138 KV" b3="A 22" />
      <ContingencyEquipment Action="L" Type="LN" b1="CNTRALOE" b2="138 KV" b3="CNT-MCD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCDSTEEL" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCDSTEEL" b2="138 KV" b3="LDMC" />
      <ContingencyEquipment Action="L" Type="LN" b1="NILES" b2="138 KV" b3="NIL-MCD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NILES" b2="138 KV" b3="B20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54090</SeqNum>
    <Name>L138.Niles-SaltSprings.1</Name>
    <LastEdit Timestamp="2024-07-16T13:39:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NILES" b2="138 KV" b3="A62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NILES" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="L" Type="LN" b1="NILES" b2="138 KV" b3="NIL-SAL1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SALTSPRG" b2="138 KV" b3="A33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTSPRG" b2="138 KV" b3="B35" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54100</SeqNum>
    <Name>L138.NorthMedina-Buckeye-LaurelRd-Brunswoe</Name>
    <LastEdit Timestamp="2025-04-14T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWOE" b2="138 KV" b3="B201" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWOE" b2="138 KV" b3="B202" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNSWOE" b2="138 KV" b3="BRU-LAU" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKEY" b2="138 KV" b3="BUC-LAU" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKEY" b2="138 KV" b3="BUC-NME" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUCKEY" b2="138 KV" b3="LDTR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAURELRO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_MEDINA" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_MEDINA" b2="138 KV" b3="B11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54110</SeqNum>
    <Name>L138.NorthMedina-WestMedina</Name>
    <LastEdit Timestamp="2025-05-16T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="N_MEDINA" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_MEDINA" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="N_MEDINA" b2="138 KV" b3="NME-WME1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMEDINA" b2="138 KV" b3="15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54140</SeqNum>
    <Name>L138.Ottawa-WestFremont.2</Name>
    <LastEdit Timestamp="2025-05-09T10:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTAWATE" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTAWATE" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B184" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B187" />
      <ContingencyEquipment Action="L" Type="LN" b1="OTTAWATE" b2="138 KV" b3="OTT-WFRE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54150</SeqNum>
    <Name>L138.Ottawa-KelseyHayes-WestFremont.1</Name>
    <LastEdit Timestamp="2025-05-06T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02KYHS" b2="138 KV" b3="02K-OTT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="02KYHS" b2="138 KV" b3="02K-WFR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02KYHS" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02KYHS" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTAWATE" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTAWATE" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54160</SeqNum>
    <Name>138/69.Ottawa.T1</Name>
    <LastEdit Timestamp="2026-06-05T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTAWATE" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTAWATE" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTAWATE" b2="69 KV" b3="B7" />
      <ContingencyEquipment Action="X" Type="XF" b1="OTTAWATE" b2="138 KV" b3="TR 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54170</SeqNum>
    <Name>138/69.Pidgeon.TR2</Name>
    <LastEdit Timestamp="2024-05-09T15:29:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PIDGEON" b2="138 KV" b3="52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIDGEON" b2="138 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIDGEON" b2="69 KV" b3="B91" />
      <ContingencyEquipment Action="X" Type="XF" b1="PIDGEON" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54180</SeqNum>
    <Name>L138.Westwood-KlondCIN [CIN]</Name>
    <LastEdit Timestamp="2025-04-24T14:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="KLONDCIN" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTWOOD" b2="138 KV" b3="20" />
      <ContingencyEquipment Action="L" Type="LN" b1="WESTWOOD" b2="138 KV" b3="WES-KLO1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54190</SeqNum>
    <Name>L138.AvonLake-Astor-Crystal-Fowles.Q1</Name>
    <LastEdit Timestamp="2024-11-19T13:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02CRESTW" b2="138 KV" b3="02C-02D1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02CRESTW" b2="138 KV" b3="LB46" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02CRESTW" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="L" Type="LN" b1="02FOWLES" b2="138 KV" b3="02F-02C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02CRYSTL" b2="138 KV" b3="CS132" />
      <ContingencyEquipment Action="L" Type="LN" b1="02DARWIN" b2="138 KV" b3="02D-02D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DARWIN" b2="138 KV" b3="CS132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DAWSON" b2="138 KV" b3="CS140" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02DAWSON" b2="138 KV" b3="D101" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02DAWSON" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASTORFE" b2="138 KV" b3="02A-02C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASTORFE" b2="138 KV" b3="AST-AVO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ASTORFE" b2="138 KV" b3="TR72" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVONLAK2" b2="138 KV" b3="AVO-AVO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENTLEY" b2="138 KV" b3="BNTLY LD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BENTLEY" b2="138 KV" b3="S1" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVONTAP" b2="138 KV" b3="AVO-BEN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENTLEYT" b2="138 KV" b3="BEN-02C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENTLEY" b2="138 KV" b3="BEN-BNQ1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54200</SeqNum>
    <Name>L138.EastLake-Newport-Mayfield.Q1</Name>
    <LastEdit Timestamp="2025-01-21T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02NEWPRT" b2="138 KV" b3="B132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02NEWPRT" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTLAKE" b2="138 KV" b3="EAS-02N1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAYFLD" b2="138 KV" b3="04M-02N1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B167" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54210</SeqNum>
    <Name>L138.PleasantValley-Faber-Fowles.Q1</Name>
    <LastEdit Timestamp="2025-08-22T15:38:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02FABER" b2="138 KV" b3="02F-02F8" />
      <ContingencyEquipment Action="L" Type="LN" b1="02FABER" b2="138 KV" b3="02F-02P2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FABER" b2="138 KV" b3="CS132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLSNTVLY" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54230</SeqNum>
    <Name>L138.Juniper-PleasantValley.Q1</Name>
    <LastEdit Timestamp="2025-04-01T15:46:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLSNTVLY" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIPER" b2="138 KV" b3="JUN-02P1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54240</SeqNum>
    <Name>L138.Lakeshore-Hamilton.Q1</Name>
    <LastEdit Timestamp="2025-02-07T12:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAKESHOR" b2="138 KV" b3="04L-02H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02HAMLTN" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESHOR" b2="138 KV" b3="B17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54260</SeqNum>
    <Name>L138.Juniper-Northfield.Q1</Name>
    <LastEdit Timestamp="2025-03-17T14:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIPER" b2="138 KV" b3="JUN-04N1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHFLD" b2="138 KV" b3="B1013" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54270</SeqNum>
    <Name>L138.AvonLake-Astor-FwlsTP-Plndealr-Fox.Q11</Name>
    <LastEdit Timestamp="2025-03-31T17:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02DUNBAR" b2="138 KV" b3="02D-02E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DUNBAR" b2="138 KV" b3="SWR132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02DUNBAR" b2="138 KV" b3="TR72" />
      <ContingencyEquipment Action="L" Type="LN" b1="02ELDEN" b2="138 KV" b3="02E-02H1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02ELDEN" b2="138 KV" b3="SW212" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02ELDEN" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02ERIE" b2="138 KV" b3="CS122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02ERIE" b2="138 KV" b3="CS422" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02ERIE" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="L" Type="LN" b1="02ERIE" b2="138 KV" b3="02E-02F1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02FW_Q11" b2="138 KV" b3="02F-02A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02FW_Q11" b2="138 KV" b3="02F-02E1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLNDEALR" b2="138 KV" b3="02P-02H1" />
      <ContingencyEquipment Action="X" Type="XF" b1="02HUMMEL" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02HUMMEL" b2="138 KV" b3="B64" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02HUMMEL" b2="138 KV" b3="SW264" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVONLAK2" b2="138 KV" b3="AVO-02A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTORFE" b2="138 KV" b3="SWR131" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ASTORFE" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="L" Type="LN" b1="02DUNBAR" b2="138 KV" b3="02D-GES2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GE_STRVL" b2="138 KV" b3="LB22" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GE_STRVL" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOX" b2="138 KV" b3="FOX-02P1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLNDEALR" b2="138 KV" b3="Q11" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLNDEALR" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54280</SeqNum>
    <Name>L138.EastLake-Lamont-Lloyd-Kipling-Nottingham.Q11</Name>
    <LastEdit Timestamp="2025-10-10T13:03:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B31" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTLAKE" b2="138 KV" b3="EAS-LAM1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KIPLNG" b2="138 KV" b3="KIP-LLO" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KIPLNG" b2="138 KV" b3="SW414" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIPLNG" b2="138 KV" b3="SWR131" />
      <ContingencyEquipment Action="L" Type="LN" b1="LLOYD" b2="138 KV" b3="LLO-LAM1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LAMONT" b2="138 KV" b3="SW313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMONT" b2="138 KV" b3="SWR132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLOYD" b2="138 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LLOYD" b2="138 KV" b3="SW15" />
      <ContingencyEquipment Action="L" Type="LN" b1="KIPLNG" b2="138 KV" b3="KIP-04N1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTTINGM" b2="138 KV" b3="Q812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTTINGM" b2="138 KV" b3="Q831" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54290</SeqNum>
    <Name>L138.Fox-Grovewood-Clinton.Q11</Name>
    <LastEdit Timestamp="2025-05-08T12:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GROVEWD" b2="138 KV" b3="GRO-02C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02CLINTN" b2="138 KV" b3="Q1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02CLINTN" b2="138 KV" b3="SW132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="B57" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOX" b2="138 KV" b3="FOX-GRO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GROVEWD" b2="138 KV" b3="B138" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54300</SeqNum>
    <Name>L138.Harding-Jennings.Q11</Name>
    <LastEdit Timestamp="2025-04-18T17:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02GARFLD" b2="138 KV" b3="02G-GAR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02GARFLD" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARFLDTP" b2="138 KV" b3="GAR-LTV1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDING2" b2="138 KV" b3="HAR-GAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="B650" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="STEELYAR" b2="138 KV" b3="JEN-STE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STEELYAR" b2="138 KV" b3="LTV-STE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LTVEAST" b2="138 KV" b3="Q2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LTVEAST" b2="138 KV" b3="Q4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LTVEAST" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LTVEAST" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54310</SeqNum>
    <Name>L138.Inland-Ivy.Q11</Name>
    <LastEdit Timestamp="2025-07-08T13:56:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="IVY" b2="138 KV" b3="IVY-INL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="138 KV" b3="Q11_IV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVY" b2="138 KV" b3="B17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54320</SeqNum>
    <Name>L138.Jordan-ClinicHospital.Q11</Name>
    <LastEdit Timestamp="2024-05-09T08:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINHOSP" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINHOSP" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINHOSP" b2="138 KV" b3="CLI-JOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JORDAN" b2="138 KV" b3="Q11_CHB3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54330</SeqNum>
    <Name>L138.Jordan-Judi-Nottingham.Q11</Name>
    <LastEdit Timestamp="2024-05-09T15:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JORDAN" b2="138 KV" b3="Q11_NG_X" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUDI" b2="138 KV" b3="JUD-04J1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUDI" b2="138 KV" b3="JUD-04N1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUDI" b2="138 KV" b3="SWR132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTTINGM" b2="138 KV" b3="Q823" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTTINGM" b2="138 KV" b3="Q831" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54350</SeqNum>
    <Name>L138.Harding-Garfld-LTVEast-SteelYard-Jennings.Q12</Name>
    <LastEdit Timestamp="2024-05-09T15:38:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02GARFLD" b2="138 KV" b3="02G-GAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02GARFLD" b2="138 KV" b3="SWR232" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARFLDTP" b2="138 KV" b3="GAR-LTV2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDING2" b2="138 KV" b3="HAR-GAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="STEELYAR" b2="138 KV" b3="JEN-STE2" />
      <ContingencyEquipment Action="L" Type="LN" b1="STEELYAR" b2="138 KV" b3="LTV-STE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LTVEAST" b2="138 KV" b3="Q11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LTVEAST" b2="138 KV" b3="Q6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LTVEAST" b2="138 KV" b3="TR11" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LTVEAST" b2="138 KV" b3="TR6" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STEELYAR" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELYAR" b2="138 KV" b3="CS4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STEELYAR" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54360</SeqNum>
    <Name>L138.Jennings-Clark.Q12</Name>
    <LastEdit Timestamp="2024-05-10T12:38:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JENNING" b2="138 KV" b3="JEN-CLA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLARK_C" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54370</SeqNum>
    <Name>L138.Eastlake-Liberty-Lloyd-Kepler-Keith.Q13</Name>
    <LastEdit Timestamp="2025-07-24T15:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02LARK" b2="138 KV" b3="02L-KEP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LARK" b2="138 KV" b3="SWR332" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LBRTY" b2="138 KV" b3="02L-02M1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LBRTY" b2="138 KV" b3="02L-LLO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LBRTY" b2="138 KV" b3="02L-PR1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02MARBLE" b2="138 KV" b3="SW331" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B33" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTLAKE" b2="138 KV" b3="EAS-MAR1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEITH" b2="138 KV" b3="SW374" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENYON" b2="138 KV" b3="KEN-KEI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENYON" b2="138 KV" b3="SWR324" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEPLER" b2="138 KV" b3="KEP-KEN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEPLER" b2="138 KV" b3="SWR328" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLN5" b2="138 KV" b3="LIN-LLO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN5" b2="138 KV" b3="SWR392" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLOYD" b2="138 KV" b3="Q3_T" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LLOYD" b2="138 KV" b3="SW35" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PROGINS" b2="138 KV" b3="LB1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PROGINS" b2="138 KV" b3="PRO-02L2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54380</SeqNum>
    <Name>L138.Harding-Jennings.Q13</Name>
    <LastEdit Timestamp="2025-04-18T17:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="B23" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDING2" b2="138 KV" b3="HAR-LTV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B301" />
      <ContingencyEquipment Action="L" Type="LN" b1="JENNING" b2="138 KV" b3="JEN-LTV3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LTVEAST" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54390</SeqNum>
    <Name>L138.PleasantValley-Hancock-Grant-Harding.Q13</Name>
    <LastEdit Timestamp="2025-02-10T11:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHARTRST" b2="138 KV" b3="SW426" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRANTFE" b2="138 KV" b3="3-T" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANTFE" b2="138 KV" b3="GRA-CHA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDING2" b2="138 KV" b3="HAR-GRA3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANTFE" b2="138 KV" b3="Q3_T" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEWAGE" b2="138 KV" b3="SEW-GRA2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANCOK" b2="138 KV" b3="HAN-SEW1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HANCOK" b2="138 KV" b3="SW434" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOK" b2="138 KV" b3="SWR331" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="B621" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLSNTVLY" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLSNTVLY" b2="138 KV" b3="HAN-02P2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAGE" b2="138 KV" b3="332" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SEWAGE" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54400</SeqNum>
    <Name>L138.Eastlake-Marble-Lloyd-Kipling-Judi-Jordan.Q14</Name>
    <LastEdit Timestamp="2024-05-09T15:33:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EASTLAKE" b2="138 KV" b3="EAS-MAR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LLOYD" b2="138 KV" b3="LLO-MAR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02MARBLE" b2="138 KV" b3="SW434" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02MARBLE" b2="138 KV" b3="SWR432" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02MARBLE" b2="138 KV" b3="TR72" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JORDAN" b2="138 KV" b3="Q14_EL_X" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUDI" b2="138 KV" b3="JUD-04J2" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUDI" b2="138 KV" b3="JUD-KIP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUDI" b2="138 KV" b3="SWR432" />
      <ContingencyEquipment Action="L" Type="LN" b1="LLOYD" b2="138 KV" b3="LLO-KIP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIPLNG" b2="138 KV" b3="SWR431" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLN5" b2="138 KV" b3="LIN-LLO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN5" b2="138 KV" b3="SWR492" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLOYD" b2="138 KV" b3="Q4_T" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LLOYD" b2="138 KV" b3="SW45" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54410</SeqNum>
    <Name>L138.Emily-Galaxie-Hummel-Furlong-Fox.Q14</Name>
    <LastEdit Timestamp="2025-03-31T17:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02EMILY" b2="138 KV" b3="B242" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02EMILY" b2="138 KV" b3="CS238" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02EMILY" b2="138 KV" b3="TR72" />
      <ContingencyEquipment Action="L" Type="LN" b1="FURLONG" b2="138 KV" b3="02H-FUR1" />
      <ContingencyEquipment Action="X" Type="XF" b1="02HUMMEL" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02HUMMEL" b2="138 KV" b3="B65" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02HUMMEL" b2="138 KV" b3="SW464" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX1" b2="138 KV" b3="CS439" />
      <ContingencyEquipment Action="L" Type="LN" b1="02HUMMEL" b2="138 KV" b3="FOX-ES2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ESSEX1" b2="138 KV" b3="TR72" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="B23" />
      <ContingencyEquipment Action="L" Type="LN" b1="FURLONG" b2="138 KV" b3="FUR-FOX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FURLONG" b2="138 KV" b3="CS432" />
      <ContingencyEquipment Action="L" Type="LN" b1="02EMILY" b2="138 KV" b3="02E-GAL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GALIXIE" b2="138 KV" b3="GAL-02H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALIXIE" b2="138 KV" b3="SWR232" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GALIXIE" b2="138 KV" b3="TR72" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54420</SeqNum>
    <Name>L138.Fox-Grovewood-Clinton.Q14</Name>
    <LastEdit Timestamp="2025-11-16T18:53:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GROVEWD" b2="138 KV" b3="GRO-02C3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02CLINTN" b2="138 KV" b3="SW132" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02CLINTN" b2="138 KV" b3="SW332" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="B56" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOX" b2="138 KV" b3="FOX-GRO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GROVEWD" b2="138 KV" b3="B438" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54430</SeqNum>
    <Name>L138.Harding-LtvEast-Jenning.Q14</Name>
    <LastEdit Timestamp="2025-03-31T18:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="B651" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDING2" b2="138 KV" b3="HAR-LTV2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="JENNING" b2="138 KV" b3="JEN-LTV4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LTVEAST" b2="138 KV" b3="Q10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LTVEAST" b2="138 KV" b3="Q5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LTVEAST" b2="138 KV" b3="TR10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LTVEAST" b2="138 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54440</SeqNum>
    <Name>L138.Inland-Ivy.Q14</Name>
    <LastEdit Timestamp="2025-07-08T13:57:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="IVY" b2="138 KV" b3="IVY-INL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="138 KV" b3="Q14_IV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVY" b2="138 KV" b3="B123" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54460</SeqNum>
    <Name>L138.PleasantValley-Harding.Q14</Name>
    <LastEdit Timestamp="2024-08-20T11:35:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HANCOK" b2="138 KV" b3="HAN-GRA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDING2" b2="138 KV" b3="HAR-GRA4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HANCOK" b2="138 KV" b3="SW434" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOK" b2="138 KV" b3="SWR431" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLSNTVLY" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANCOK" b2="138 KV" b3="HAN-02P1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54470</SeqNum>
    <Name>L138.Ashtabula-Millenum-Zenith.Q15</Name>
    <LastEdit Timestamp="2024-05-09T08:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ASHTABUL" b2="138 KV" b3="A301" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASHTABUL" b2="138 KV" b3="ASH-MIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="138 KV" b3="B143" />
      <ContingencyEquipment Action="L" Type="LN" b1="ZENITH" b2="138 KV" b3="MIC-ZEN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILLENUM" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PITTCONN" b2="138 KV" b3="Q15_CS4" />
      <ContingencyEquipment Action="L" Type="LN" b1="ZENITH" b2="138 KV" b3="PIT-ZEN1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="ZENITH" b2="138 KV" b3="SW656" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZENITH" b2="138 KV" b3="SWR532" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54480</SeqNum>
    <Name>L138.GrandRiver-Painesvill-Nursery-LeroyCenter.Q15</Name>
    <LastEdit Timestamp="2025-04-07T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDRVR" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDRVR" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANDRVR" b2="138 KV" b3="GRR-PAI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B148" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAINESV2" b2="138 KV" b3="LER-PAI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NURSERY" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NURSERY" b2="138 KV" b3="Q1_T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NURSERY" b2="138 KV" b3="Q3_T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NURSERY" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NURSERY" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NURSERY" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAINESV" b2="138 KV" b3="A2_Q15" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAINESV" b2="138 KV" b3="PAI-NUR1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PAINESV" b2="138 KV" b3="SW56" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PAINESV2" b2="138 KV" b3="A6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAINESV2" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAINESV2" b2="138 KV" b3="PAI-NUR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54490</SeqNum>
    <Name>L138.Juniper-Inca-LTVFurnace-Jenning-Clark.Q15</Name>
    <LastEdit Timestamp="2025-03-17T14:17:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIPER" b2="138 KV" b3="JUN-02I2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LTVFRN" b2="138 KV" b3="LTV-02I2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02INCA" b2="138 KV" b3="SWR532" />
      <ContingencyEquipment Action="L" Type="LN" b1="JENNING" b2="138 KV" b3="JEN-CLA3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARK_C" b2="138 KV" b3="Q3_T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLARK_C" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="LTVFRN" b2="138 KV" b3="LTV-JEN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LTVFRN" b2="138 KV" b3="SWR232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LTVFRN" b2="138 KV" b3="SWR332" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LTVFRN" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LTVFRN" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54500</SeqNum>
    <Name>L138.Ashtabula-Zenith-PittConn.Q16</Name>
    <LastEdit Timestamp="2024-05-09T14:49:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ASHTABUL" b2="138 KV" b3="ASH-ZEN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="138 KV" b3="B146" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PITTCONN" b2="138 KV" b3="Q16_CS5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PITTCONN" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ZENITH" b2="138 KV" b3="PIT-ZEN2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="ZENITH" b2="138 KV" b3="SW656" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZENITH" b2="138 KV" b3="SWR632" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54510</SeqNum>
    <Name>L138.Fowles-Dunkirk-NASA.Q16</Name>
    <LastEdit Timestamp="2024-05-09T15:11:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02DUNKRK" b2="138 KV" b3="02D-02N1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DUNKRK" b2="138 KV" b3="CS631" />
      <ContingencyEquipment Action="L" Type="LN" b1="02FOWLES" b2="138 KV" b3="02F-02D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02NASA" b2="138 KV" b3="Q16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54520</SeqNum>
    <Name>L138.Juniper-Inca-Newburgh-Ivy.Q18</Name>
    <LastEdit Timestamp="2025-02-10T13:23:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02INCA" b2="138 KV" b3="02I-04N1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIPER" b2="138 KV" b3="JUN-02I1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02INCA" b2="138 KV" b3="SWR532" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02INCA" b2="138 KV" b3="SWR832" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02INCA" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVY" b2="138 KV" b3="B19" />
      <ContingencyEquipment Action="L" Type="LN" b1="IVY" b2="138 KV" b3="IVY-04N1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWBURGH" b2="138 KV" b3="Q8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54530</SeqNum>
    <Name>L138.Horizon-Jennings.Q1</Name>
    <LastEdit Timestamp="2025-12-23T10:27:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AIR_PROD" b2="138 KV" b3="AIR-JEN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HORIZON1" b2="138 KV" b3="HOR-AIR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AIR_PROD" b2="138 KV" b3="Q1_T_132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AIR_PROD" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON1" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54540</SeqNum>
    <Name>L138.Ashtabula-Sanborn-AustnBg-Spruce-LeroyCtr.Q2</Name>
    <LastEdit Timestamp="2024-05-09T14:55:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ASHTABUL" b2="138 KV" b3="ASH-04S2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="138 KV" b3="B137" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="AUSTNBG" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="AUSTNBG" b2="138 KV" b3="AUS-04S2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUSTNBG" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPRUCE" b2="138 KV" b3="SPR-AUS1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AUSTNBG" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEROYCEN" b2="138 KV" b3="SPR-04L1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SANBORN" b2="138 KV" b3="211" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRUCE" b2="138 KV" b3="CS4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54550</SeqNum>
    <Name>L138.AvonLake-Admral-Lorain-Slatr-Crystl-Fowles.Q2</Name>
    <LastEdit Timestamp="2024-05-09T15:03:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02FOWLES" b2="138 KV" b3="02F-02C3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02CRYSTL" b2="138 KV" b3="CS232" />
      <ContingencyEquipment Action="L" Type="LN" b1="SLATER" b2="138 KV" b3="SLA-02CR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LORAIN" b2="138 KV" b3="02L-ADM1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LORAIN" b2="138 KV" b3="02L-SL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LORAIN" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02LORAIN" b2="138 KV" b3="D12" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVONLAK2" b2="138 KV" b3="AVO-ADM1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ADMIRAL" b2="138 KV" b3="SW224" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLATER" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SLATER" b2="138 KV" b3="LB22" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SLATER" b2="138 KV" b3="TR71" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54560</SeqNum>
    <Name>L138.Eastlake-Mayfield.Q2</Name>
    <LastEdit Timestamp="2024-10-22T16:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTLAKE" b2="138 KV" b3="EAS-04M1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B267" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54570</SeqNum>
    <Name>L138.Fowles-PleasantValley.Q2</Name>
    <LastEdit Timestamp="2024-05-09T08:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02FOWLES" b2="138 KV" b3="02F-02P1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B603" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLSNTVLY" b2="138 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54580</SeqNum>
    <Name>L138.Horizon-Jennings.Q2</Name>
    <LastEdit Timestamp="2025-12-23T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AIR_PROD" b2="138 KV" b3="AIR-JEN2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HORIZON1" b2="138 KV" b3="HOR-AIR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AIR_PROD" b2="138 KV" b3="Q2_T_232" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AIR_PROD" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON1" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54590</SeqNum>
    <Name>L138.Juniper-Pleasant Valley.Q2</Name>
    <LastEdit Timestamp="2025-05-20T11:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLSNTVLY" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIPER" b2="138 KV" b3="JUN-02P2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54600</SeqNum>
    <Name>L138.Lakeshore-Hamilton.Q2</Name>
    <LastEdit Timestamp="2025-05-08T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAKESHOR" b2="138 KV" b3="04L-02H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02HAMLTN" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESHOR" b2="138 KV" b3="B15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54610</SeqNum>
    <Name>L138.MayField-Norway-Maxwell-NorthField.Q2</Name>
    <LastEdit Timestamp="2025-03-18T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LONGFIEL" b2="138 KV" b3="LON-MAX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGFIEL" b2="138 KV" b3="SWR222" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LONGFIEL" b2="138 KV" b3="TR72" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORWAY" b2="138 KV" b3="NOR-MAX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAXWELL" b2="138 KV" b3="SWR218" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B150" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORWAY" b2="138 KV" b3="NOR-04M1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHFLD" b2="138 KV" b3="B17" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONGFIEL" b2="138 KV" b3="LON-04N1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORWAY" b2="138 KV" b3="CS222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORWAY" b2="138 KV" b3="CS231" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NORWAY" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NORWAY" b2="138 KV" b3="TR72" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54620</SeqNum>
    <Name>L138.Northfield-Juniper.Q2</Name>
    <LastEdit Timestamp="2025-03-17T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B1151" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIPER" b2="138 KV" b3="JUN-04N2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHFLD" b2="138 KV" b3="B18" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54630</SeqNum>
    <Name>L138.Ashtabula-Sanborn-Stacy.Q3</Name>
    <LastEdit Timestamp="2024-11-20T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ASHTABUL" b2="138 KV" b3="ASH-04S3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="X" Type="XF" b1="SANBORN" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SANBORN" b2="138 KV" b3="311" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SANBORN" b2="138 KV" b3="331" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANBORN" b2="138 KV" b3="Q3_T" />
      <ContingencyEquipment Action="L" Type="LN" b1="SANBORN" b2="138 KV" b3="SAN-STAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STACY" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STACY" b2="138 KV" b3="B9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54640</SeqNum>
    <Name>L138.AvonLake-Bntly-CrestW-Dawsn-Lorain-Fowles.Q3</Name>
    <LastEdit Timestamp="2024-05-09T15:09:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02CRESTW" b2="138 KV" b3="02C-02D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02CRESTW" b2="138 KV" b3="CS332" />
      <ContingencyEquipment Action="L" Type="LN" b1="02DARWIN" b2="138 KV" b3="02D-02D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DARWIN" b2="138 KV" b3="CS332" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DAWSON" b2="138 KV" b3="CS340" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02DAWSON" b2="138 KV" b3="D101" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02DAWSON" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LORAIN" b2="138 KV" b3="02L-FOW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVONTAP" b2="138 KV" b3="AVO-LOR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02LORAIN" b2="138 KV" b3="D13" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVONLAK2" b2="138 KV" b3="AVO-AVO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BENTLEY" b2="138 KV" b3="S1" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVONTAP" b2="138 KV" b3="AVO-BEN2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENTLEYT" b2="138 KV" b3="BEN-02C3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENTLEY" b2="138 KV" b3="BEN-BNQ3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54650</SeqNum>
    <Name>L138.Eastlake-Nathan-Mayfield.Q3</Name>
    <LastEdit Timestamp="2025-12-04T17:37:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B367" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATHAN" b2="138 KV" b3="B339" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTLAKE" b2="138 KV" b3="EAS-NAT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAYFLD" b2="138 KV" b3="MAY-NAT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54660</SeqNum>
    <Name>L138.Fowles-Faber-Griffin-PleasantValley.Q3</Name>
    <LastEdit Timestamp="2025-01-17T15:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02FABER" b2="138 KV" b3="02F-02F9" />
      <ContingencyEquipment Action="L" Type="LN" b1="02FABER" b2="138 KV" b3="02F-GRI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FABER" b2="138 KV" b3="CS332" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02FABER" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRIFFN" b2="138 KV" b3="GRI-02P1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRIFFN" b2="138 KV" b3="SWR332" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRIFFN" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLSNTVLY" b2="138 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54670</SeqNum>
    <Name>L138.Juniper-PleasantValley.Q3</Name>
    <LastEdit Timestamp="2025-03-17T14:18:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLSNTVLY" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIPER" b2="138 KV" b3="JUN-02P3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54690</SeqNum>
    <Name>L138.AvonLake-Admiral-Lorain-Slater-Fowles.Q4</Name>
    <LastEdit Timestamp="2025-11-17T15:57:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02FOWLES" b2="138 KV" b3="02F-CLI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LORAIN" b2="138 KV" b3="02L-ADM2" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LORAIN" b2="138 KV" b3="02L-SL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LORAIN" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02LORAIN" b2="138 KV" b3="D12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02LORAIN" b2="138 KV" b3="D13" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVONLAK2" b2="138 KV" b3="AVO-ADM2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ADMIRAL" b2="138 KV" b3="SW224" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADMIRAL" b2="138 KV" b3="SWR 422" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ADMIRAL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="SLATER" b2="138 KV" b3="SLA-CL1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLIFFRD" b2="138 KV" b3="SW414" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFFRD" b2="138 KV" b3="SWR422" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLIFFRD" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SLATER" b2="138 KV" b3="LB22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54700</SeqNum>
    <Name>L138.Eastlake-Nathan-Mayfield.Q4</Name>
    <LastEdit Timestamp="2025-05-02T13:01:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B27" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTLAKE" b2="138 KV" b3="EAS-NAT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B467" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAYFLD" b2="138 KV" b3="MAY-NAT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATHAN" b2="138 KV" b3="Q2_T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54710</SeqNum>
    <Name>L138.Fowles-Griffin-PleasantValley.Q4</Name>
    <LastEdit Timestamp="2025-01-21T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B604" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRIFFN" b2="138 KV" b3="GRI-02F1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRIFFN" b2="138 KV" b3="GRI-02P2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GRIFFN" b2="138 KV" b3="SW434" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRIFFN" b2="138 KV" b3="TR72" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLSNTVLY" b2="138 KV" b3="B7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54720</SeqNum>
    <Name>L138.Juniper-PleasantValley.Q4</Name>
    <LastEdit Timestamp="2024-05-09T15:14:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLSNTVLY" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIPER" b2="138 KV" b3="JUN-02P4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54730</SeqNum>
    <Name>L138.Inland-Lakeshore.Q4</Name>
    <LastEdit Timestamp="2024-05-09T08:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAKESHOR" b2="138 KV" b3="04L-INL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="138 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESHOR" b2="138 KV" b3="B16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54740</SeqNum>
    <Name>L138.Mayfield-Maxwell-LongField-NorthField.Q4</Name>
    <LastEdit Timestamp="2025-02-27T14:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LONGFIEL" b2="138 KV" b3="LON-MAX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGFIEL" b2="138 KV" b3="SWR422" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAXWELL" b2="138 KV" b3="SWR418" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAXWELL" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B177" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAXWELL" b2="138 KV" b3="MAX-04M1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHFLD" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONGFIEL" b2="138 KV" b3="LON-04N2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54750</SeqNum>
    <Name>L138.EastLeipsic-Lammer</Name>
    <LastEdit Timestamp="2024-11-27T10:49:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELEIPSIC" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELEIPSIC" b2="138 KV" b3="ELE-LAMM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMMER" b2="138 KV" b3="H024Q2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMMER" b2="138 KV" b3="H024Q8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54760</SeqNum>
    <Name>L138.Richland-JohnsManville-SWDefiance</Name>
    <LastEdit Timestamp="2025-11-04T16:36:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02DEFISW" b2="138 KV" b3="02D-02A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02AYERSV" b2="138 KV" b3="A544" />
      <ContingencyEquipment Action="L" Type="LN" b1="02JMP" b2="138 KV" b3="02J-02D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DEFISW" b2="138 KV" b3="CS1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02DEFISW" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02JMP2" b2="138 KV" b3="02J-02J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02JMP" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="RICHLND" b2="138 KV" b3="RIC-02J1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02JMP2" b2="138 KV" b3="TR10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02JMP2" b2="138 KV" b3="TR11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="138 KV" b3="B13236" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54770</SeqNum>
    <Name>138/69.Richland.TR4</Name>
    <LastEdit Timestamp="2025-11-03T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="69 KV" b3="B6944" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="138 KV" b3="CS43" />
      <ContingencyEquipment Action="X" Type="XF" b1="RICHLND" b2="138 KV" b3="TR-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54780</SeqNum>
    <Name>L138.Riverbend-SaltSprings</Name>
    <LastEdit Timestamp="2024-05-09T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RVERBDOE" b2="138 KV" b3="11" />
      <ContingencyEquipment Action="L" Type="LN" b1="SALTSPRG" b2="138 KV" b3="SAL-RVE1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SALTSPRG" b2="138 KV" b3="A50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTSPRG" b2="138 KV" b3="B42" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54790</SeqNum>
    <Name>L138.SouthAkron-Firestone</Name>
    <LastEdit Timestamp="2025-12-12T10:33:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FIRESTON" b2="138 KV" b3="A 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIRESTON" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAKRONFE" b2="138 KV" b3="SAK-FIR1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SAKRONFE" b2="138 KV" b3="A371" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRONFE" b2="138 KV" b3="B12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54800</SeqNum>
    <Name>L138.Sammis-Nevada-Boardman</Name>
    <LastEdit Timestamp="2024-05-09T15:27:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BOARDMAN" b2="138 KV" b3="A146" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOARDMAN" b2="138 KV" b3="B85" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOARDMAN" b2="138 KV" b3="BOA-NEV1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEVADAOE" b2="138 KV" b3="TR1 LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEVADAOE" b2="138 KV" b3="TR3 LD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SAMMISFE" b2="138 KV" b3="A96" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEVADAOE" b2="138 KV" b3="NEV-SAMM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54810</SeqNum>
    <Name>L138.Sammis-Toronto</Name>
    <LastEdit Timestamp="2024-05-09T15:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SAMMISFE" b2="138 KV" b3="A156" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="138 KV" b3="B75" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAMMISFE" b2="138 KV" b3="SAM-TOR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="138 KV" b3="B15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54830</SeqNum>
    <Name>L138.Sammis-Hagan</Name>
    <LastEdit Timestamp="2026-04-22T15:21:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAGAN" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAGAN" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="138 KV" b3="B45" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAGAN" b2="138 KV" b3="HAG-SAMI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54840</SeqNum>
    <Name>L138.Seville-Star</Name>
    <LastEdit Timestamp="2025-05-20T11:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEVILL" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEVILL_R" b2="138 KV" b3="SEV-SEV" />
      <ContingencyEquipment Action="L" Type="LN" b1="STAR_FE" b2="138 KV" b3="STA-SEV1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SEVILL_R" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="B223" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="B317" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54850</SeqNum>
    <Name>138/69.Seville.TR1</Name>
    <LastEdit Timestamp="2025-12-29T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEVILL" b2="69 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEVILL" b2="138 KV" b3="B52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEVILL" b2="69 KV" b3="B54" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEVILL" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54870</SeqNum>
    <Name>L138.Sharon-Shenango</Name>
    <LastEdit Timestamp="2024-05-10T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHARON" b2="138 KV" b3="A58" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARON" b2="138 KV" b3="B60" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHENANGO" b2="138 KV" b3="SHE-SHA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="48" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54880</SeqNum>
    <Name>138/69.Sharon.TR2</Name>
    <LastEdit Timestamp="2024-05-10T12:32:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHARON" b2="69 KV" b3="A36" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHARON" b2="138 KV" b3="A50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARON" b2="69 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARON" b2="138 KV" b3="B52" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHARON" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54890</SeqNum>
    <Name>138/69.Sharon.TR3</Name>
    <LastEdit Timestamp="2024-05-10T12:34:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHARON" b2="69 KV" b3="A14" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHARON" b2="138 KV" b3="A40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARON" b2="69 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARON" b2="138 KV" b3="B42" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHARON" b2="138 KV" b3="TR 3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54900</SeqNum>
    <Name>L138.Shenango-CedarSt.Z-99</Name>
    <LastEdit Timestamp="2024-05-10T12:46:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CEDAROE" b2="138 KV" b3="A261" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAROE" b2="138 KV" b3="B258" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHENANGO" b2="138 KV" b3="SHE-CED1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="40" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54910</SeqNum>
    <Name>L138.Shenango-McDowell.Z-115</Name>
    <LastEdit Timestamp="2024-05-10T12:47:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MCDOWLOE" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCDOWLOE" b2="138 KV" b3="B87" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHENANGO" b2="138 KV" b3="SHE-MCD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="36" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54920</SeqNum>
    <Name>138/69.Shinrock.TR1</Name>
    <LastEdit Timestamp="2024-05-10T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHINROCK" b2="138 KV" b3="42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHINROCK" b2="138 KV" b3="49" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHINROCK" b2="69 KV" b3="B55" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHINROCK" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54930</SeqNum>
    <Name>138/69.SaltSprings.TR2</Name>
    <LastEdit Timestamp="2024-05-10T12:30:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTSPRG" b2="69 KV" b3="B55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTSPRG" b2="138 KV" b3="B56" />
      <ContingencyEquipment Action="X" Type="XF" b1="SALTSPRG" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54940</SeqNum>
    <Name>138/69.SaltSprings.TR3</Name>
    <LastEdit Timestamp="2024-05-10T12:30:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTSPRG" b2="69 KV" b3="B133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTSPRG" b2="138 KV" b3="B192" />
      <ContingencyEquipment Action="X" Type="XF" b1="SALTSPRG" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54960</SeqNum>
    <Name>L138.Star-WadsworthMuni</Name>
    <LastEdit Timestamp="2025-05-20T11:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02WADS" b2="138 KV" b3="01-101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02WADS" b2="138 KV" b3="01-103" />
      <ContingencyEquipment Action="L" Type="LN" b1="STAR_FE" b2="138 KV" b3="STA-02W1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="151" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="B319" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54970</SeqNum>
    <Name>138/69.Star.TR5</Name>
    <LastEdit Timestamp="2025-05-20T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="STAR_FE" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="69 KV" b3="B186" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54980</SeqNum>
    <Name>138/69.STAR.TR6</Name>
    <LastEdit Timestamp="2025-05-20T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="151" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="69 KV" b3="B155" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="B318" />
      <ContingencyEquipment Action="X" Type="XF" b1="STAR_FE" b2="138 KV" b3="TR6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>54990</SeqNum>
    <Name>L138.Talmadge-Westgate</Name>
    <LastEdit Timestamp="2025-04-07T11:31:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02WESTGT" b2="138 KV" b3="02W-TAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02WESTGT" b2="138 KV" b3="3316" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TALWGATE" b2="138 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TALWGATE" b2="138 KV" b3="B40" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55000</SeqNum>
    <Name>138/69.Tangy.TR1</Name>
    <LastEdit Timestamp="2024-11-08T11:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="138 KV" b3="B238" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="69 KV" b3="B276" />
      <ContingencyEquipment Action="X" Type="XF" b1="TANGY" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55010</SeqNum>
    <Name>138/69.Tangy.TR2</Name>
    <LastEdit Timestamp="2024-11-08T11:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="69 KV" b3="B166" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="69 KV" b3="B169" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="138 KV" b3="B56" />
      <ContingencyEquipment Action="X" Type="XF" b1="TANGY" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55030</SeqNum>
    <Name>138/69.Toussiant.TR1</Name>
    <LastEdit Timestamp="2024-05-10T12:36:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="02TOUSNT" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02TOUSNT" b2="69 KV" b3="B7220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02TOUSNT" b2="138 KV" b3="CS13010" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55040</SeqNum>
    <Name>L138.Urban-Firestone</Name>
    <LastEdit Timestamp="2025-12-18T17:16:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FIRESTON" b2="138 KV" b3="A 11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIRESTON" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIRESTON" b2="138 KV" b3="FIR-URB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="URBAN" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="URBAN" b2="138 KV" b3="B241" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55050</SeqNum>
    <Name>L138.Valley-Theiss</Name>
    <LastEdit Timestamp="2024-05-10T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="THEISS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THEISS" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="THEISS" b2="138 KV" b3="THE-VAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEYOE" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="VALLEYOE" b2="138 KV" b3="A 26" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55060</SeqNum>
    <Name>138/69.Vulcan.TR10</Name>
    <LastEdit Timestamp="2024-09-24T16:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VULCAN" b2="138 KV" b3="B13391" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VULCAN" b2="69 KV" b3="B6982" />
      <ContingencyEquipment Action="X" Type="XF" b1="VULCAN" b2="138 KV" b3="TR10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55070</SeqNum>
    <Name>L138.WestAkron-Rosemont-Pine</Name>
    <LastEdit Timestamp="2024-05-10T12:49:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02ROSEMT" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINEOE" b2="138 KV" b3="PIN-02R1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02ROSEMT" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAKRON" b2="138 KV" b3="WAK-02R1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEOE" b2="138 KV" b3="B132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEOE" b2="138 KV" b3="B133" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WAKRON" b2="138 KV" b3="A123" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKRON" b2="138 KV" b3="B14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55080</SeqNum>
    <Name>138/69.WestAkron.TR1</Name>
    <LastEdit Timestamp="2024-05-10T12:37:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="WAKRON" b2="138 KV" b3="A105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKRON" b2="138 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKRON" b2="69 KV" b3="B53" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAKRON" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55090</SeqNum>
    <Name>138/69.Wauseon.TR21</Name>
    <LastEdit Timestamp="2024-05-13T11:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUSEON" b2="138 KV" b3="B32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUSEON" b2="69 KV" b3="B7165" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAUSEON" b2="138 KV" b3="TR_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55100</SeqNum>
    <Name>L138.Brookside-Wellington</Name>
    <LastEdit Timestamp="2025-12-05T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKSID" b2="138 KV" b3="A63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSID" b2="138 KV" b3="B60" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKSID" b2="138 KV" b3="BRO-WEL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLINGT" b2="138 KV" b3="B61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLINGT" b2="138 KV" b3="B64" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55110</SeqNum>
    <Name>L138.WestFremont-Woodville</Name>
    <LastEdit Timestamp="2026-03-27T10:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="WFREMONT" b2="138 KV" b3="WFR-WOO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVLTE" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVLTE" b2="138 KV" b3="B14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55130</SeqNum>
    <Name>138/69.WestFremont.TR2</Name>
    <LastEdit Timestamp="2024-05-13T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="69 KV" b3="B138" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="X" Type="XF" b1="WFREMONT" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55140</SeqNum>
    <Name>138/69.West Ravenna.TR2</Name>
    <LastEdit Timestamp="2024-05-13T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WRAVENNA" b2="138 KV" b3="B95" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WRAVENNA" b2="69 KV" b3="B96" />
      <ContingencyEquipment Action="X" Type="XF" b1="WRAVENNA" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55150</SeqNum>
    <Name>138/69.West Ravenna.TR3</Name>
    <LastEdit Timestamp="2024-05-13T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WRAVENNA" b2="69 KV" b3="B125" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WRAVENNA" b2="138 KV" b3="B136" />
      <ContingencyEquipment Action="X" Type="XF" b1="WRAVENNA" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55160</SeqNum>
    <Name>L138.Boardman-Wickliffe</Name>
    <LastEdit Timestamp="2025-04-24T14:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BOARDMAN" b2="138 KV" b3="A152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOARDMAN" b2="138 KV" b3="B89" />
      <ContingencyEquipment Action="L" Type="LN" b1="WICKLIFF" b2="138 KV" b3="WIC-BOA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WICKLIFF" b2="138 KV" b3="B103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WICKLIFF" b2="138 KV" b3="B146" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55170</SeqNum>
    <Name>L138.Beaver-West Lorain</Name>
    <LastEdit Timestamp="2024-05-13T11:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="13.8 KV" b3="183" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="13.2 KV" b3="B101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="B163" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="13.2 KV" b3="B57" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAVER" b2="138 KV" b3="CT6TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAVER" b2="138 KV" b3="TB1AB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55180</SeqNum>
    <Name>L138.Bluebell-Alliance</Name>
    <LastEdit Timestamp="2024-05-13T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02AMSTED" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02AMSTED" b2="138 KV" b3="A9" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEBELL" b2="138 KV" b3="BLU-02A1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BLUEBELL" b2="138 KV" b3="A191" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEBELL" b2="138 KV" b3="B9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55190</SeqNum>
    <Name>L138.BMF-PPPine</Name>
    <LastEdit Timestamp="2025-04-07T15:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BMF" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BMF" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BMF" b2="138 KV" b3="CS50" />
      <ContingencyEquipment Action="L" Type="LN" b1="PPPINE" b2="138 KV" b3="PPP-BMF1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BMF" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PPPINE" b2="138 KV" b3="B56" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55200</SeqNum>
    <Name>138/69.Brim.1</Name>
    <LastEdit Timestamp="2025-06-23T12:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="02BRIM" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02BRIM" b2="69 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02BRIM" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02BRIM" b2="138 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55210</SeqNum>
    <Name>L138.Carlisle-Johnson</Name>
    <LastEdit Timestamp="2024-05-13T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="67" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="70" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARLISLE" b2="138 KV" b3="CAR-FIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDST" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSOFE" b2="138 KV" b3="JOH-FIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSOFE" b2="138 KV" b3="174" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="JOHNSOFE" b2="138 KV" b3="A199" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55220</SeqNum>
    <Name>L138.Carlisle-Shinrock</Name>
    <LastEdit Timestamp="2024-05-13T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="58" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARLISLE" b2="138 KV" b3="CAR-CON1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHINROCK" b2="138 KV" b3="CON-SHI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONCAST" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHINROCK" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHINROCK" b2="138 KV" b3="49" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55230</SeqNum>
    <Name>138/69.Carlisle.TR2</Name>
    <LastEdit Timestamp="2024-05-13T11:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="219" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="221" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="69 KV" b3="B151" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARLISLE" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55240</SeqNum>
    <Name>138/69.Chamberlin.T1</Name>
    <LastEdit Timestamp="2024-05-13T11:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B181" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="69 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B69" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHAMBROE" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55260</SeqNum>
    <Name>138/23.Cloverdale.T3</Name>
    <LastEdit Timestamp="2025-11-17T16:06:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="23 KV" b3="T3I" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVEROE" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55270</SeqNum>
    <Name>138/23.Cloverdale.T2</Name>
    <LastEdit Timestamp="2025-11-17T16:06:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="138 KV" b3="B41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="23 KV" b3="T2I" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVEROE" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55280</SeqNum>
    <Name>L138.Crossland-Shenango.Z-122</Name>
    <LastEdit Timestamp="2024-05-17T10:44:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSFE" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHENANGO" b2="138 KV" b3="SHE-CRO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="18" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55290</SeqNum>
    <Name>L138.Crossland-Shenango.Z-121</Name>
    <LastEdit Timestamp="2024-05-17T10:45:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSFE" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHENANGO" b2="138 KV" b3="SHE-CRO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="48" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="138 KV" b3="52" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55300</SeqNum>
    <Name>L138.Dixie-Jeep</Name>
    <LastEdit Timestamp="2025-07-11T13:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02JP" b2="138 KV" b3="02J-DIX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02JP" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DIXIEFE" b2="138 KV" b3="B13293" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DIXIEFE" b2="138 KV" b3="B46" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55310</SeqNum>
    <Name>L138.Longview-Armco</Name>
    <LastEdit Timestamp="2024-05-13T11:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="02ARMCO" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02ARMCO" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONGVIOE" b2="138 KV" b3="LON-02A2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONGVIOE" b2="138 KV" b3="A107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGVIOE" b2="138 KV" b3="B80" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55320</SeqNum>
    <Name>L138.London-EastSpringfield.1</Name>
    <LastEdit Timestamp="2025-06-25T15:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ESPROHED" b2="138 KV" b3="A238" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESPROHED" b2="138 KV" b3="B74" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONDONOE" b2="138 KV" b3="LON-ESP1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONDONOE" b2="138 KV" b3="A72" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONDONOE" b2="138 KV" b3="B127" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55340</SeqNum>
    <Name>138/69.EastSpringfield.TR6</Name>
    <LastEdit Timestamp="2025-06-23T15:33:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ESPROHED" b2="69 KV" b3="A216" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ESPROHED" b2="138 KV" b3="A252" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESPROHED" b2="69 KV" b3="B214" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESPROHED" b2="138 KV" b3="B250" />
      <ContingencyEquipment Action="X" Type="XF" b1="ESPROHED" b2="138 KV" b3="TR6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55350</SeqNum>
    <Name>L138.Hanna-WestRavenna.1</Name>
    <LastEdit Timestamp="2026-04-01T13:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANNAOE" b2="138 KV" b3="HAN-WRA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WRAVENNA" b2="138 KV" b3="B21" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55360</SeqNum>
    <Name>L138.Hanna-WestRavenna.2</Name>
    <LastEdit Timestamp="2026-04-01T13:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANNAOE" b2="138 KV" b3="HAN-WRA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WRAVENNA" b2="138 KV" b3="B17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55370</SeqNum>
    <Name>138/69.Ironville.TR1</Name>
    <LastEdit Timestamp="2024-05-13T11:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONVILL" b2="138 KV" b3="B13208" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONVILL" b2="69 KV" b3="B6960" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONVILL" b2="69 KV" b3="B6961" />
      <ContingencyEquipment Action="X" Type="XF" b1="IRONVILL" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55380</SeqNum>
    <Name>L138.Jackman-ToledoHospital</Name>
    <LastEdit Timestamp="2024-05-17T09:42:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKMAN" b2="138 KV" b3="B13328" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKMAN" b2="138 KV" b3="JAC-TOL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOLEDOHP" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOLEDOHP" b2="138 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55390</SeqNum>
    <Name>138/69.Leaside.TR1</Name>
    <LastEdit Timestamp="2024-05-14T08:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LESIDE" b2="138 KV" b3="29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LESIDE" b2="138 KV" b3="36" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LESIDE" b2="69 KV" b3="A4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LESIDE" b2="69 KV" b3="B5" />
      <ContingencyEquipment Action="X" Type="XF" b1="LESIDE" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55400</SeqNum>
    <Name>L138.Lemoyne-Brim</Name>
    <LastEdit Timestamp="2024-10-16T11:46:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02BRIM" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02BRIM" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="02BRIM" b2="138 KV" b3="BRI-LEMO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="138 KV" b3="13213" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55410</SeqNum>
    <Name>138/69.Longview.TR4</Name>
    <LastEdit Timestamp="2025-04-07T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONGVIOE" b2="138 KV" b3="A129" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONGVIOE" b2="69 KV" b3="A132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGVIOE" b2="138 KV" b3="B31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGVIOE" b2="69 KV" b3="B69" />
      <ContingencyEquipment Action="X" Type="XF" b1="LONGVIOE" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55420</SeqNum>
    <Name>138/69.Longview.TR5</Name>
    <LastEdit Timestamp="2024-05-14T08:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONGVIOE" b2="138 KV" b3="A221" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONGVIOE" b2="69 KV" b3="A226" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGVIOE" b2="138 KV" b3="B219" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGVIOE" b2="69 KV" b3="B224" />
      <ContingencyEquipment Action="X" Type="XF" b1="LONGVIOE" b2="138 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55430</SeqNum>
    <Name>NewCastle.U4</Name>
    <LastEdit Timestamp="2024-05-17T09:46:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASOE" b2="69 KV" b3="B42" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWCASOE" b2="14 KV" b3="G4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASOE" b2="14 KV" b3="GSU-4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWCASOE" b2="14 KV" b3="NL40" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWCASOE" b2="69 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55440</SeqNum>
    <Name>NewCastle.U3</Name>
    <LastEdit Timestamp="2024-05-17T09:48:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASOE" b2="69 KV" b3="B54" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWCASOE" b2="14 KV" b3="G3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASOE" b2="14 KV" b3="GSU-3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWCASOE" b2="14 KV" b3="NL30" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWCASOE" b2="69 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55450</SeqNum>
    <Name>138/69.Pine Penn Power.TR1</Name>
    <LastEdit Timestamp="2025-12-24T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PPPINE" b2="69 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PPPINE" b2="138 KV" b3="B36" />
      <ContingencyEquipment Action="X" Type="XF" b1="PPPINE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55460</SeqNum>
    <Name>138/69.PinePennPower.TR2</Name>
    <LastEdit Timestamp="2024-05-17T09:39:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="PPPINE" b2="69 KV" b3="A32" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PPPINE" b2="138 KV" b3="A46" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PPPINE" b2="69 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PPPINE" b2="138 KV" b3="B44" />
      <ContingencyEquipment Action="X" Type="XF" b1="PPPINE" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55480</SeqNum>
    <Name>L138.PleasantValley-Hickory-Bath-WestAkron.Q22</Name>
    <LastEdit Timestamp="2025-02-10T13:39:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BATHFE" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BATHFE" b2="138 KV" b3="BAT-HICO" />
      <ContingencyEquipment Action="L" Type="LN" b1="BATHFE" b2="138 KV" b3="BAT-WAKR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BATHFE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HICKRY" b2="138 KV" b3="SW101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKRY" b2="138 KV" b3="SWR135" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HICKRY" b2="138 KV" b3="TR72" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLSNTVLY" b2="138 KV" b3="02P-HIC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLSNTVLY" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WAKRON" b2="138 KV" b3="A89" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKRON" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55510</SeqNum>
    <Name>L138.Fowles-Elden-Hummel-PlainDealer-Fox.Q12</Name>
    <LastEdit Timestamp="2025-03-31T18:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02ELDEN" b2="138 KV" b3="02E-02F5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02ELDEN" b2="138 KV" b3="SWR231" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02ELDEN" b2="138 KV" b3="TR72" />
      <ContingencyEquipment Action="L" Type="LN" b1="02FORD" b2="138 KV" b3="02F-FO1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="02FORD" b2="138 KV" b3="SW131" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="02FORD" b2="138 KV" b3="SW231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FORD" b2="138 KV" b3="SWR230" />
      <ContingencyEquipment Action="L" Type="LN" b1="02FOWLES" b2="138 KV" b3="02F-02E2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="L" Type="LN" b1="FORDTP" b2="138 KV" b3="02H-FOR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GM_CLEVL" b2="138 KV" b3="02H-GM12" />
      <ContingencyEquipment Action="X" Type="XF" b1="02HUMMEL" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02HUMMEL" b2="138 KV" b3="B80" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02HUMMEL" b2="138 KV" b3="SW564" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX1" b2="138 KV" b3="CS539" />
      <ContingencyEquipment Action="L" Type="LN" b1="02HUMMEL" b2="138 KV" b3="FOX-ES1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ESSEX1" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GM_CLEVL" b2="138 KV" b3="227" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GM_CLEVL" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOX" b2="138 KV" b3="FOX-02P2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GM_CLEVL" b2="138 KV" b3="GMC-02P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLNDEALR" b2="138 KV" b3="Q12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLNDEALR" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55520</SeqNum>
    <Name>L138.Fox-Clinton.Q12</Name>
    <LastEdit Timestamp="2025-05-23T14:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="02CLINTN" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02CLINTN" b2="138 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02CLINTN" b2="138 KV" b3="CS231" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOX" b2="138 KV" b3="FOX-02C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02CLINTN" b2="138 KV" b3="Q2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02CLINTN" b2="11 KV" b3="V2-T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="B58" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55530</SeqNum>
    <Name>L138.Fowles-FordTP-Hummel-GmCleveland-Fox.Q13</Name>
    <LastEdit Timestamp="2025-03-31T18:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02FORD" b2="138 KV" b3="02F-FO2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="02FORD" b2="138 KV" b3="SW131" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="02FORD" b2="138 KV" b3="SW231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FORD" b2="138 KV" b3="SWR130" />
      <ContingencyEquipment Action="L" Type="LN" b1="02FOWLES" b2="138 KV" b3="02F-02F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="FORDTP" b2="138 KV" b3="02H-FOR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GM_CLEVL" b2="138 KV" b3="02H-GM11" />
      <ContingencyEquipment Action="X" Type="XF" b1="02HUMMEL" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02HUMMEL" b2="138 KV" b3="B75" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02HUMMEL" b2="138 KV" b3="SW364" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="L" Type="LN" b1="FURLONG" b2="138 KV" b3="FUR1-FOX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FURLONG" b2="138 KV" b3="CS332" />
      <ContingencyEquipment Action="L" Type="LN" b1="FURLONG" b2="138 KV" b3="FUR-GMC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FURLONG" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GM_CLEVL" b2="138 KV" b3="327" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GM_CLEVL" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55540</SeqNum>
    <Name>L138.Fox-Grovewood-Clinton.Q13</Name>
    <LastEdit Timestamp="2025-05-08T18:47:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02CLINTN" b2="138 KV" b3="CS331" />
      <ContingencyEquipment Action="L" Type="LN" b1="GROVEWD" b2="138 KV" b3="GRO-02C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02CLINTN" b2="138 KV" b3="Q3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02CLINTN" b2="138 KV" b3="SW332" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="B55" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOX" b2="138 KV" b3="FOX-GRO3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GROVEWD" b2="138 KV" b3="B338" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55550</SeqNum>
    <Name>L138.AvonLake-Clifford-Erie-EmilyTp-Emily.Q14</Name>
    <LastEdit Timestamp="2025-11-16T18:53:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02DUNBAR" b2="138 KV" b3="SWR332" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02DUNBAR" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02EMILY" b2="138 KV" b3="B242" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02EMILY" b2="138 KV" b3="CS138" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02EMILY" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="L" Type="LN" b1="02ERIE" b2="138 KV" b3="CLI-02E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02ERIE" b2="138 KV" b3="CS422" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVONLAK2" b2="138 KV" b3="AVO-CLI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFFRD" b2="138 KV" b3="SWR122" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLIFFRD" b2="138 KV" b3="TR72" />
      <ContingencyEquipment Action="L" Type="LN" b1="02DUNBAR" b2="138 KV" b3="02D-EMI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02EMILY" b2="138 KV" b3="02E-EMI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02ERIE" b2="138 KV" b3="02E-EMI2" />
      <ContingencyEquipment Action="L" Type="LN" b1="02DUNBAR" b2="138 KV" b3="02D-GES" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GE_STRVL" b2="138 KV" b3="LB22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55560</SeqNum>
    <Name>L138.Fowles-Dell-NASACleveland.Q15</Name>
    <LastEdit Timestamp="2024-05-17T09:42:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02NASA" b2="138 KV" b3="02N-02D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DELL" b2="138 KV" b3="CS6" />
      <ContingencyEquipment Action="L" Type="LN" b1="02FOWLES" b2="138 KV" b3="02F-02D3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02NASA" b2="138 KV" b3="Q15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55580</SeqNum>
    <Name>L138.Fowles-DkDlT-Ford-Dell-Nasa.Q18</Name>
    <LastEdit Timestamp="2025-05-15T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02DELL" b2="138 KV" b3="02D-DKD" />
      <ContingencyEquipment Action="L" Type="LN" b1="02NASA" b2="138 KV" b3="02N-02D2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="02DELL" b2="138 KV" b3="A17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DELL" b2="138 KV" b3="CS7" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLVHOP" b2="138 KV" b3="02E-CL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02EATON" b2="138 KV" b3="CS832" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="DK_DL_T" b2="138 KV" b3="DKD-02F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02NASA" b2="138 KV" b3="Q-18" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CLVHOP" b2="138 KV" b3="A31" />
      <ContingencyEquipment Action="L" Type="LN" b1="IX_CENTR" b2="138 KV" b3="IXC-CL2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLVHOP" b2="138 KV" b3="Q18" />
      <ContingencyEquipment Action="L" Type="LN" b1="DK_DL_T" b2="138 KV" b3="DKD-IX2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="IX_CENTR" b2="138 KV" b3="SW78" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="IX_CENTR" b2="138 KV" b3="SW822" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55590</SeqNum>
    <Name>L138.LakeShore-LakeRoad.Q21</Name>
    <LastEdit Timestamp="2024-05-17T09:43:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02LAKERD" b2="138 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LAKERD" b2="138 KV" b3="CB3" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKESHOR" b2="138 KV" b3="04L-02L1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESHOR" b2="138 KV" b3="B22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55600</SeqNum>
    <Name>L138.Clinton-CPP_RIDG.Q22</Name>
    <LastEdit Timestamp="2025-05-23T14:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02CLINTN" b2="138 KV" b3="B23" />
      <ContingencyEquipment Action="L" Type="LN" b1="CPP_RIDG" b2="138 KV" b3="RID-02C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_RIDG" b2="138 KV" b3="CS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_RIDG" b2="138 KV" b3="RGCB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_RIDG" b2="138 KV" b3="RGCB4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55610</SeqNum>
    <Name>L138.Nottingham-NottinghamCPP.Q23</Name>
    <LastEdit Timestamp="2024-05-17T09:45:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02CPP_NH" b2="138 KV" b3="CS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02CPP_NH" b2="138 KV" b3="NG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02CPP_NH" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02CPP_NH" b2="138 KV" b3="02C-04N1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTTINGM" b2="138 KV" b3="Q812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTTINGM" b2="138 KV" b3="Q823" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55620</SeqNum>
    <Name>L138.Towerline-Huffip(ILL_EQ)</Name>
    <LastEdit Timestamp="2025-01-30T15:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUFFIP" b2="138 KV" b3="H10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWRL" b2="138 KV" b3="H5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWRL" b2="138 KV" b3="H7" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUFFIP" b2="138 KV" b3="HUF-TWRL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55630</SeqNum>
    <Name>L138.Northfield-Juniper.Q3</Name>
    <LastEdit Timestamp="2024-05-14T08:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIPER" b2="138 KV" b3="JUN-04N3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHFLD" b2="138 KV" b3="B1014" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55640</SeqNum>
    <Name>L138.Juniper-Nortfield.Q4</Name>
    <LastEdit Timestamp="2025-02-27T14:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B92" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIPER" b2="138 KV" b3="JUN-04N4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHFLD" b2="138 KV" b3="B21" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55650</SeqNum>
    <Name>Richland.PeakerUnit4</Name>
    <LastEdit Timestamp="2026-03-27T10:58:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="13.8 KV" b3="B14_CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RICHLND" b2="13.8 KV" b3="RP84" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55660</SeqNum>
    <Name>Richland.PeakerUnit5</Name>
    <LastEdit Timestamp="2026-03-27T10:58:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="13.8 KV" b3="B17_CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RICHLND" b2="13.8 KV" b3="RP85" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55670</SeqNum>
    <Name>Richland.PeakerUnit6</Name>
    <LastEdit Timestamp="2026-03-27T10:58:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="13.8 KV" b3="B20_CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RICHLND" b2="13.8 KV" b3="RP86" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55690</SeqNum>
    <Name>L138.NapoleonMuni-Stryker</Name>
    <LastEdit Timestamp="2025-04-10T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NAPLNN" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAPLNN" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NAPLNN" b2="138 KV" b3="NAP-STRY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRYKER" b2="138 KV" b3="B72" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55700</SeqNum>
    <Name>Stryker.SP81</Name>
    <LastEdit Timestamp="2024-05-17T09:50:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STRYKER" b2="13.2 KV" b3="GENCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="STRYKER" b2="13.2 KV" b3="SP81" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55710</SeqNum>
    <Name>L138.Angola-VulcanTap-Vulcan-Wentworth</Name>
    <LastEdit Timestamp="2025-06-12T11:56:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02ANGOLA" b2="138 KV" b3="02A-VUL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02ANGOLA" b2="138 KV" b3="B13471" />
      <ContingencyEquipment Action="L" Type="LN" b1="02WENTWT" b2="138 KV" b3="02W-VUL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02WENTWT" b2="138 KV" b3="B29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02WENTWT" b2="138 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VULCAN" b2="138 KV" b3="B13396" />
      <ContingencyEquipment Action="L" Type="LN" b1="VULCANTP" b2="138 KV" b3="VUL-VUL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55720</SeqNum>
    <Name>Beaver.WestLorain.U2</Name>
    <LastEdit Timestamp="2024-05-17T09:52:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="159" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="13.8 KV" b3="179" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAVER" b2="345 KV" b3="CT2TR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAVER" b2="13.8 KV" b3="LD20" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEAVER" b2="13.8 KV" b3="WL20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55730</SeqNum>
    <Name>Beaver.WestLorain.U3</Name>
    <LastEdit Timestamp="2024-05-17T09:55:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="160" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="13.8 KV" b3="180" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAVER" b2="345 KV" b3="CT3TR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAVER" b2="13.8 KV" b3="LD30" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEAVER" b2="13.8 KV" b3="WL30" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55740</SeqNum>
    <Name>Beaver.WestLorain.U4</Name>
    <LastEdit Timestamp="2024-05-17T09:56:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="13.8 KV" b3="181" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="B161" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAVER" b2="345 KV" b3="CT4TR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAVER" b2="13.8 KV" b3="LD40" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEAVER" b2="13.8 KV" b3="WL40" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55750</SeqNum>
    <Name>Beaver.WestLorain.U5</Name>
    <LastEdit Timestamp="2024-05-17T10:13:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="13.8 KV" b3="182" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAVER" b2="345 KV" b3="CT5TR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAVER" b2="13.8 KV" b3="LD50" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEAVER" b2="13.8 KV" b3="WL50" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55770</SeqNum>
    <Name>Beaver.WestLorain.U_A</Name>
    <LastEdit Timestamp="2024-05-17T10:14:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="13.2 KV" b3="B57" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEAVER" b2="13.2 KV" b3="WL-A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55780</SeqNum>
    <Name>Beaver.WestLorain.U_B</Name>
    <LastEdit Timestamp="2024-05-17T10:14:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="13.2 KV" b3="B101" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEAVER" b2="13.2 KV" b3="WL-B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55810</SeqNum>
    <Name>Ashtabula.138.CAP1</Name>
    <LastEdit Timestamp="2024-05-17T11:05:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="138 KV" b3="B41" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ASHTABUL" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55820</SeqNum>
    <Name>Ashtabula.138.CAP3</Name>
    <LastEdit Timestamp="2024-05-17T11:05:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="138 KV" b3="B43" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ASHTABUL" b2="138 KV" b3="CAP3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55830</SeqNum>
    <Name>AvonLake.138.CAP1</Name>
    <LastEdit Timestamp="2024-05-17T11:06:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="138 KV" b3="B102" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="AVONLAK2" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55840</SeqNum>
    <Name>AvonLake.138.CAP2</Name>
    <LastEdit Timestamp="2024-05-17T11:06:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="138 KV" b3="B302" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="AVONLAK2" b2="138 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55870</SeqNum>
    <Name>Babb.138.CAP1</Name>
    <LastEdit Timestamp="2024-05-17T11:07:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="BABB" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABB" b2="138 KV" b3="CS119" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55880</SeqNum>
    <Name>CPPEInd.138.CAP1</Name>
    <LastEdit Timestamp="2024-05-17T11:08:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="02E_IND" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02E_IND" b2="138 KV" b3="CS-CAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55890</SeqNum>
    <Name>CPPLake.138.CAP2</Name>
    <LastEdit Timestamp="2024-05-17T11:08:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="02LAKERD" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LAKERD" b2="138 KV" b3="CS-CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55900</SeqNum>
    <Name>CPPCollinwood.138.CAP1</Name>
    <LastEdit Timestamp="2024-05-17T11:07:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="02COLLIN" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02COLLIN" b2="138 KV" b3="CS-CAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55910</SeqNum>
    <Name>CPPEast.138.CAP1</Name>
    <LastEdit Timestamp="2024-05-17T11:07:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="CPP_EAST" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_EAST" b2="138 KV" b3="CS-CAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55920</SeqNum>
    <Name>138/34.Crissinger.TR1</Name>
    <LastEdit Timestamp="2024-11-21T14:27:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISS" b2="138 KV" b3="B102" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CRISS" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRISS" b2="34 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRISS" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55930</SeqNum>
    <Name>138/34.Crissinger.TR2</Name>
    <LastEdit Timestamp="2024-11-21T14:27:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISS" b2="138 KV" b3="B 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISS" b2="138 KV" b3="B99" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CRISS" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRISS" b2="34 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRISS" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55940</SeqNum>
    <Name>EastLake.138.CAP1</Name>
    <LastEdit Timestamp="2024-05-17T11:40:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B45" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="EASTLAKE" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55950</SeqNum>
    <Name>EastLake.138.CAP2</Name>
    <LastEdit Timestamp="2024-05-17T11:40:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B54" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="EASTLAKE" b2="138 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55960</SeqNum>
    <Name>EastSpringfield.138.CAP6</Name>
    <LastEdit Timestamp="2024-05-17T11:41:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="ESPROHED" b2="138 KV" b3="CAP6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESPROHED" b2="138 KV" b3="CS291" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55970</SeqNum>
    <Name>Fowles.138.CAP2</Name>
    <LastEdit Timestamp="2024-05-17T11:41:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B200" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="02FOWLES" b2="138 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55980</SeqNum>
    <Name>Fowles.138.CAP3</Name>
    <LastEdit Timestamp="2024-05-17T11:41:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B300" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="02FOWLES" b2="138 KV" b3="C3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>55990</SeqNum>
    <Name>Fowles.138.CAP4</Name>
    <LastEdit Timestamp="2024-05-17T11:41:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B400" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="02FOWLES" b2="138 KV" b3="C4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56000</SeqNum>
    <Name>Fowles.138.CAP1</Name>
    <LastEdit Timestamp="2024-05-17T11:42:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B100" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="02FOWLES" b2="138 KV" b3="C1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56010</SeqNum>
    <Name>FOX Q1C_CAP BK1 138 KV</Name>
    <LastEdit Timestamp="2025-03-31T16:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="CS1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FOX" b2="138 KV" b3="Q1FXC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56020</SeqNum>
    <Name>FOX Q2C_CAP BK2 138 KV</Name>
    <LastEdit Timestamp="2025-03-31T16:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FOX" b2="138 KV" b3="Q2FXC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56030</SeqNum>
    <Name>FOX Q3C_CAP BK3 138 KV</Name>
    <LastEdit Timestamp="2025-03-31T16:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="CS3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FOX" b2="138 KV" b3="Q3FXC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56040</SeqNum>
    <Name>FOX Q4C_CAP BK4 138 KV</Name>
    <LastEdit Timestamp="2025-03-31T16:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX" b2="138 KV" b3="CS4" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FOX" b2="138 KV" b3="Q4FXC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56050</SeqNum>
    <Name>138.Granger(FE).Cap</Name>
    <LastEdit Timestamp="2025-10-24T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANGROE" b2="138 KV" b3="B52" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GRANGROE" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56060</SeqNum>
    <Name>Greenfield.138.CAP1</Name>
    <LastEdit Timestamp="2024-05-17T11:42:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENFOE" b2="138 KV" b3="B61" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GREENFOE" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56070</SeqNum>
    <Name>Harding.345.Cap.CAP1</Name>
    <LastEdit Timestamp="2025-01-21T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B116" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HARDING2" b2="345 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56080</SeqNum>
    <Name>Harding.345.Cap.CAP2</Name>
    <LastEdit Timestamp="2025-01-21T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B117" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HARDING2" b2="345 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56090</SeqNum>
    <Name>Harding.138.Cap.Q1C</Name>
    <LastEdit Timestamp="2025-01-21T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="CS13" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HARDING2" b2="138 KV" b3="Q1C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56100</SeqNum>
    <Name>Harding.138.Cap.Q2C</Name>
    <LastEdit Timestamp="2025-01-21T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="CS15" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HARDING2" b2="138 KV" b3="Q2C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56110</SeqNum>
    <Name>Harding.138.Cap.Q3C </Name>
    <LastEdit Timestamp="2025-01-21T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="CS17" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HARDING2" b2="138 KV" b3="Q3C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56120</SeqNum>
    <Name>Harding.138.Cap.Q4C</Name>
    <LastEdit Timestamp="2025-01-21T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="CS19" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HARDING2" b2="138 KV" b3="Q4C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56130</SeqNum>
    <Name>Inland.138.Cap.Q3</Name>
    <LastEdit Timestamp="2025-07-08T13:57:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="INLAND" b2="138 KV" b3="Q3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="138 KV" b3="Q3_C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56140</SeqNum>
    <Name>Inland.138.Cap.Q4</Name>
    <LastEdit Timestamp="2025-07-08T13:57:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="INLAND" b2="138 KV" b3="Q4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="138 KV" b3="Q4_C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56150</SeqNum>
    <Name>Ivanhoe.138.CAP1</Name>
    <LastEdit Timestamp="2024-05-17T11:43:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IVANHOOE" b2="138 KV" b3="B107" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="IVANHOOE" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56160</SeqNum>
    <Name>Jackman.138.CAP2</Name>
    <LastEdit Timestamp="2024-05-17T11:43:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="JACKMAN" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKMAN" b2="138 KV" b3="CS01" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56170</SeqNum>
    <Name>Juniper.345.CAP1</Name>
    <LastEdit Timestamp="2024-05-17T11:43:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="JUNIPER" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B70" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56180</SeqNum>
    <Name>Juniper.345.CAP2</Name>
    <LastEdit Timestamp="2024-05-17T11:43:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="JUNIPER" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B80" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56190</SeqNum>
    <Name>Longview.138.CAP1</Name>
    <LastEdit Timestamp="2024-05-17T11:44:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGVIOE" b2="138 KV" b3="B24" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LONGVIOE" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56200</SeqNum>
    <Name>MaplePennPower.138.CAP1</Name>
    <LastEdit Timestamp="2024-05-17T11:44:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLEOE" b2="138 KV" b3="B50" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MAPLEOE" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56210</SeqNum>
    <Name>Mayfield.138.CAP1</Name>
    <LastEdit Timestamp="2024-05-17T11:44:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B105" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MAYFLD" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56220</SeqNum>
    <Name>Mayfield.138.CAP2</Name>
    <LastEdit Timestamp="2024-05-17T11:45:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B110" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MAYFLD" b2="138 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56230</SeqNum>
    <Name>Mayfield.138.CAP3</Name>
    <LastEdit Timestamp="2024-05-17T11:45:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B155" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MAYFLD" b2="138 KV" b3="CAP3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56240</SeqNum>
    <Name>Mayfield.138.CAP4</Name>
    <LastEdit Timestamp="2024-05-17T11:45:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B120" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MAYFLD" b2="138 KV" b3="CAP4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56250</SeqNum>
    <Name>Midway.138.CAP3306</Name>
    <LastEdit Timestamp="2024-05-17T11:45:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="MIDWAYTE" b2="138 KV" b3="CAP_3306" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="CS43" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56260</SeqNum>
    <Name>Midway.138.CAP3307</Name>
    <LastEdit Timestamp="2024-05-17T11:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="MIDWAYTE" b2="138 KV" b3="CAP_3307" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="CS51" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56270</SeqNum>
    <Name>Richland.138.Cap13234</Name>
    <LastEdit Timestamp="2026-04-02T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="138 KV" b3="B13234" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="RICHLND" b2="138 KV" b3="CAP13234" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56280</SeqNum>
    <Name>Richland.138.Cap13230</Name>
    <LastEdit Timestamp="2024-05-17T11:46:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="138 KV" b3="B13230" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="RICHLND" b2="138 KV" b3="CAP13230" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56290</SeqNum>
    <Name>Roberts.138.Cap2</Name>
    <LastEdit Timestamp="2024-05-31T15:20:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="ROBERTOE" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTOE" b2="138 KV" b3="CS161" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56300</SeqNum>
    <Name>SouthAkron.138.Cap3</Name>
    <LastEdit Timestamp="2024-05-31T15:19:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="SAKRONFE" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRONFE" b2="138 KV" b3="CS407" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56310</SeqNum>
    <Name>138/69.Stryker.T3</Name>
    <LastEdit Timestamp="2024-12-24T13:45:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STRYKER" b2="138 KV" b3="B63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRYKER" b2="69 KV" b3="B6811" />
      <ContingencyEquipment Action="U" Type="GEN" b1="STRYKER" b2="13.2 KV" b3="SP81" />
      <ContingencyEquipment Action="X" Type="XF" b1="STRYKER" b2="138 KV" b3="TR3-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="STRYKER" b2="69 KV" b3="TR3-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="STRYKER" b2="13.2 KV" b3="TR3-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56320</SeqNum>
    <Name>Swanton.138.Cap</Name>
    <LastEdit Timestamp="2024-05-31T15:20:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02SWANTN" b2="138 KV" b3="B13417" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="02SWANTN" b2="138 KV" b3="CAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56330</SeqNum>
    <Name>Vulcan.138.CapJBUS</Name>
    <LastEdit Timestamp="2024-05-31T15:20:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VULCAN" b2="138 KV" b3="B13398" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="VULCAN" b2="138 KV" b3="JBUSCAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56340</SeqNum>
    <Name>WestAkron.138.Cap3</Name>
    <LastEdit Timestamp="2024-05-31T15:21:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="WAKRON" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKRON" b2="138 KV" b3="CS291" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56350</SeqNum>
    <Name>WestMedina.138.Cap1</Name>
    <LastEdit Timestamp="2024-05-31T15:21:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WMEDINA" b2="138 KV" b3="B25" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WMEDINA" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56360</SeqNum>
    <Name>Carlisle.138.Cap1</Name>
    <LastEdit Timestamp="2024-05-31T15:11:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="210" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CARLISLE" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56370</SeqNum>
    <Name>Carlisle.138.Cap2</Name>
    <LastEdit Timestamp="2024-05-31T15:10:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLISLE" b2="138 KV" b3="204" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CARLISLE" b2="138 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56380</SeqNum>
    <Name>Chamberlin.138.Cap1</Name>
    <LastEdit Timestamp="2024-05-31T15:11:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B164" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CHAMBROE" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56390</SeqNum>
    <Name>Chamberlin.138.Cap2</Name>
    <LastEdit Timestamp="2024-05-31T15:12:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B172" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CHAMBROE" b2="138 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56400</SeqNum>
    <Name>Cloverdale.138.Cap1</Name>
    <LastEdit Timestamp="2024-05-31T15:12:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="CLOVEROE" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="138 KV" b3="CS291" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56410</SeqNum>
    <Name>Gilchrist.138.Cap1</Name>
    <LastEdit Timestamp="2024-05-31T15:13:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="GLCRSTOE" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCRSTOE" b2="138 KV" b3="CS131" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56420</SeqNum>
    <Name>L138.PleasantValley-Issler-Sewage-Grant-Hardin.Q11</Name>
    <LastEdit Timestamp="2025-04-01T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRANTFE" b2="138 KV" b3="1-T" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDING2" b2="138 KV" b3="HAR-GRA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANTFE" b2="138 KV" b3="Q1 T" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEWAGE" b2="138 KV" b3="SEW-GRA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="L" Type="LN" b1="ISSLER" b2="138 KV" b3="ISS-SEW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ISSLER" b2="138 KV" b3="SWR122" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ISSLER" b2="138 KV" b3="TR72" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLSNTVLY" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="ISSLER" b2="138 KV" b3="ISS-02P1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAGE" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SEWAGE" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56430</SeqNum>
    <Name>L138.PleasantValley-Issler-Grant-Harding.Q12</Name>
    <LastEdit Timestamp="2025-02-10T11:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARTRST" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANTFE" b2="138 KV" b3="GRA-CHA2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHARTRST" b2="138 KV" b3="TRA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHARTRST" b2="138 KV" b3="TRB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRANTFE" b2="138 KV" b3="2-T" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDING2" b2="138 KV" b3="HAR-GRA2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ISSLER" b2="138 KV" b3="ISS-GRA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANTFE" b2="138 KV" b3="Q2 T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="B620" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ISSLER" b2="138 KV" b3="SWR222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLSNTVLY" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="L" Type="LN" b1="ISSLER" b2="138 KV" b3="ISS-02P2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56440</SeqNum>
    <Name>L138.Juniper-Irwin-Iron-LTVFurnace-Jenning.Q16</Name>
    <LastEdit Timestamp="2025-03-17T14:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02IRON" b2="138 KV" b3="02I-IRW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02IRON" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LTVFRN" b2="138 KV" b3="LTV-02R" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02IRON" b2="138 KV" b3="TR72" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIPER" b2="138 KV" b3="JUN-IRW2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="IRWIN" b2="138 KV" b3="SW617" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IRWIN" b2="138 KV" b3="SWR631" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="LTVFRN" b2="138 KV" b3="LTV-JEN3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LTVFRN" b2="138 KV" b3="SWR132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LTVFRN" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56450</SeqNum>
    <Name>L138.Fowles-Dunkirk-Ford-DkDlT-Nasa.Q17</Name>
    <LastEdit Timestamp="2025-05-15T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02DUNKRK" b2="138 KV" b3="CS731" />
      <ContingencyEquipment Action="L" Type="LN" b1="DK_DL_T" b2="138 KV" b3="DKD-02D" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLVHOP" b2="138 KV" b3="02E-CL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02EATON" b2="138 KV" b3="CS732" />
      <ContingencyEquipment Action="L" Type="LN" b1="02FOWLES" b2="138 KV" b3="02F-02D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FOWLES" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="L" Type="LN" b1="DK_DL_T" b2="138 KV" b3="DKD-02N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02NASA" b2="138 KV" b3="Q17" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CLVHOP" b2="138 KV" b3="A31" />
      <ContingencyEquipment Action="L" Type="LN" b1="IX_CENTR" b2="138 KV" b3="IXC-CL1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLVHOP" b2="138 KV" b3="Q17" />
      <ContingencyEquipment Action="L" Type="LN" b1="DK_DL_T" b2="138 KV" b3="DKD-IX1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="IX_CENTR" b2="138 KV" b3="SW722" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="IX_CENTR" b2="138 KV" b3="SW78" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56460</SeqNum>
    <Name>L138.Juniper-Irwin-Iron-Newburgh-Ivy.Q17</Name>
    <LastEdit Timestamp="2025-02-10T11:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02IRON" b2="138 KV" b3="02I-IRW1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02IRON" b2="138 KV" b3="IRW-04N1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02IRON" b2="138 KV" b3="LB1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="02IRON" b2="138 KV" b3="LB22" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIPER" b2="138 KV" b3="JUN-IRW1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="IRWIN" b2="138 KV" b3="SW617" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IRWIN" b2="138 KV" b3="SWR731" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVY" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="L" Type="LN" b1="IVY" b2="138 KV" b3="IVY-04N2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="138 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWBURGH" b2="69 KV" b3="N7 T" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWBURGH" b2="138 KV" b3="TR7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56470</SeqNum>
    <Name>L138.Ashtbula-Sanborn-Spruce-LeroyCenter.Q4</Name>
    <LastEdit Timestamp="2024-05-31T15:14:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ASHTABUL" b2="138 KV" b3="ASH-04S4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="138 KV" b3="B140" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B83" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B84" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPRUCE" b2="138 KV" b3="SPR-04L2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SANBORN" b2="138 KV" b3="411" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SANBORN" b2="138 KV" b3="431" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANBORN" b2="138 KV" b3="Q4_T" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPRUCE" b2="138 KV" b3="SPR-04S3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRUCE" b2="138 KV" b3="CS5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56480</SeqNum>
    <Name>L138.Barberton-Star.1</Name>
    <LastEdit Timestamp="2024-05-31T15:15:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BARBERTO" b2="138 KV" b3="45" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BARBERTO" b2="138 KV" b3="A 207" />
      <ContingencyEquipment Action="L" Type="LN" b1="STAR_FE" b2="138 KV" b3="STA-BAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56490</SeqNum>
    <Name>L138.Barberton-Star.2</Name>
    <LastEdit Timestamp="2024-05-31T15:18:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BARBERTO" b2="138 KV" b3="124" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BARBERTO" b2="138 KV" b3="A 200" />
      <ContingencyEquipment Action="L" Type="LN" b1="STAR_FE" b2="138 KV" b3="STA-BAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56500</SeqNum>
    <Name>230/115.Northwest.TX7</Name>
    <LastEdit Timestamp="2026-01-20T17:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NWEST" b2="230 KV" b3="H752" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWEST" b2="115 KV" b3="L752" />
      <ContingencyEquipment Action="X" Type="XF" b1="NWEST" b2="230 KV" b3="TX-7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56540</SeqNum>
    <Name>L345.Dequine-MeadowLake.2</Name>
    <LastEdit Timestamp="2025-08-25T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEQUINE" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEQUINE" b2="345 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADOWLK" b2="345 KV" b3="DEQ-MEA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWLK" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWLK" b2="345 KV" b3="C1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56550</SeqNum>
    <Name>L345.Reynolds-Olive.34532</Name>
    <LastEdit Timestamp="2024-05-31T15:18:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="345 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="OLIVE" b2="345 KV" b3="OLI-REY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="34531-32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="34532" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56810</SeqNum>
    <Name>L138.Everson-SouthFairmont-Eldora</Name>
    <LastEdit Timestamp="2025-01-15T17:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELDORA" b2="138 KV" b3="ELD-SFRT" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELDORA" b2="138 KV" b3="EVERSON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERSON" b2="138 KV" b3="ELDORA" />
      <ContingencyEquipment Action="L" Type="LN" b1="EVERSON" b2="138 KV" b3="EVR-SFRT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SFAIRMNT" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SFAIRMNT" b2="138 KV" b3="TX1 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56820</SeqNum>
    <Name>L115.Westport-Orchards.110585</Name>
    <LastEdit Timestamp="2024-05-30T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="110585" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="585_595" />
      <ContingencyEquipment Action="L" Type="LN" b1="ORCHARDS" b2="115 KV" b3="ORC-WES5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="110585" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="585-521" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56830</SeqNum>
    <Name>230/69.Cedar.T8</Name>
    <LastEdit Timestamp="2024-05-30T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CEDAR" b2="230 KV" b3="CEDAR T8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB ES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB GQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="230 KV" b3="GCB LL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="230 KV" b3="GCB SS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56840</SeqNum>
    <Name>230/69.Cedar.T9</Name>
    <LastEdit Timestamp="2024-05-30T13:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CEDAR" b2="230 KV" b3="CEDAR T9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB IO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB KM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="230 KV" b3="GCB QQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="230 KV" b3="LK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56860</SeqNum>
    <Name>765/345.DonMarquis.T1</Name>
    <LastEdit Timestamp="2024-12-18T12:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="345 KV" b3="E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="345 KV" b3="E2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="765 KV" b3="J" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARQUIS2" b2="765 KV" b3="XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56870</SeqNum>
    <Name>765/345.Jefferson.T2</Name>
    <LastEdit Timestamp="2024-05-30T13:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFERSO" b2="765 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFERSO" b2="345 KV" b3="E" />
      <ContingencyEquipment Action="X" Type="XF" b1="JEFFERSO" b2="765 KV" b3="XF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56900</SeqNum>
    <Name>345/138.Roberts.T2</Name>
    <LastEdit Timestamp="2024-05-31T15:10:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="345 KV" b3="B CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROBERTS2" b2="345 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>56990</SeqNum>
    <Name>Linden.CC2 &amp; CT1201</Name>
    <LastEdit Timestamp="2025-08-06T14:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="230 KV" b3="1201" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="1201 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINDEN" b2="18 KV" b3="1201 CT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINDEN" b2="18 KV" b3="2001 GEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="2001 HS" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="230 KV" b3="2100" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="230 KV" b3="2101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="2101 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINDEN" b2="18 KV" b3="2101 CT" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="230 KV" b3="2201" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="2201 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINDEN" b2="18 KV" b3="2201 CT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINDEN" b2="18 KV" b3="AUX2201" />
      <ContingencyEquipment Action="S" Type="SD" b1="LINDEN" b2="230 KV" b3="UNIT12SD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57050</SeqNum>
    <Name>L500.ChalkPoint-Cheltenham.5073</Name>
    <LastEdit Timestamp="2025-08-29T13:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="500 KV" b3="11AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="500 KV" b3="11BB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHALKPT" b2="500 KV" b3="CHA-CHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHELTENH" b2="500 KV" b3="4A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHELTENH" b2="500 KV" b3="4B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57060</SeqNum>
    <Name>L500.BurchesHill-PossumPoint.560</Name>
    <LastEdit Timestamp="2024-05-30T14:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="500 KV" b3="11B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="500 KV" b3="11C" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURCHESH" b2="500 KV" b3="BUR-POS" />
      <ContingencyEquipment Action="L" Type="LN" b1="POSS560" b2="500 KV" b3="560A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="500 KV" b3="560T571" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="500 KV" b3="H1T560" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57070</SeqNum>
    <Name>500/230.BurchesHill.T2</Name>
    <LastEdit Timestamp="2024-05-30T13:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="500 KV" b3="11A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="500 KV" b3="11B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="3BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="3CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURCHESH" b2="500 KV" b3="NO.2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57080</SeqNum>
    <Name>500/230.BurchesHill.T4</Name>
    <LastEdit Timestamp="2024-05-30T13:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="500 KV" b3="13A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="500 KV" b3="13B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="7B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="7C" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURCHESH" b2="500 KV" b3="TR NO 4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57090</SeqNum>
    <Name>L115.Thirty First St.-Westfall</Name>
    <LastEdit Timestamp="2025-10-16T13:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="THIRTYST" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THIRTYST" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="THIRTYST" b2="115 KV" b3="THI-WES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTFALL" b2="115 KV" b3="B18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTFALL" b2="115 KV" b3="B6 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57100</SeqNum>
    <Name>L138.DutchFork-Windsor</Name>
    <LastEdit Timestamp="2025-10-10T12:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUTCHFOR" b2="138 KV" b3="WINDAPS" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUTCHFOR" b2="138 KV" b3="DUT-WIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND APS" b2="138 KV" b3="DUTCHFOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57110</SeqNum>
    <Name>230/138.Holmesburg.T8</Name>
    <LastEdit Timestamp="2024-05-31T15:09:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLMESBU" b2="230 KV" b3="565" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLMESBU" b2="138 KV" b3="805 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLMESBU" b2="138 KV" b3="825 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOLMESBU" b2="230 KV" b3="HOL 8TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57120</SeqNum>
    <Name>138/13.Holmesburg.T12</Name>
    <LastEdit Timestamp="2024-05-30T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLMESBU" b2="13 KV" b3="12TRLS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLMESBU" b2="138 KV" b3="825 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOLMESBU" b2="138 KV" b3="HOL12TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57150</SeqNum>
    <Name>L500.GreenlandGap-MtStorm.5572</Name>
    <LastEdit Timestamp="2026-03-12T13:36:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENGAP" b2="500 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENGAP" b2="500 KV" b3="GL2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENGAP" b2="500 KV" b3="GRE-MTS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="572TB3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="572TB4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57160</SeqNum>
    <Name>L500.GreenlandGap-MeadowBrook.540</Name>
    <LastEdit Timestamp="2026-05-08T14:59:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENGAP" b2="500 KV" b3="B18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENGAP" b2="500 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADOWBR" b2="500 KV" b3="MEA-GRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="500 KV" b3="B145" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="500 KV" b3="B146" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57190</SeqNum>
    <Name>L500.Loudoun-Meadowbrook.5535</Name>
    <LastEdit Timestamp="2025-01-09T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="500 KV" b3="502T535" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="500 KV" b3="H1T535" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADOWBR" b2="500 KV" b3="LOU-MEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="500 KV" b3="MDL2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="500 KV" b3="MDL3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57200</SeqNum>
    <Name>L500.MtStorm-Meadowbrook.5529</Name>
    <LastEdit Timestamp="2024-06-14T10:10:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="500 KV" b3="MDL07" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="500 KV" b3="MDL08" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADOWBR" b2="500 KV" b3="MTS-MEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="529TB3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="529TB4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57210</SeqNum>
    <Name>L500.502Junction-MtStorm (TRAIL)</Name>
    <LastEdit Timestamp="2026-01-13T09:06:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="500 KV" b3="5L_3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="500 KV" b3="5L_4" />
      <ContingencyEquipment Action="L" Type="LN" b1="502JCT" b2="500 KV" b3="MTS-502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="536TB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="536TB2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57230</SeqNum>
    <Name>230/115.WaughChapel.T2</Name>
    <LastEdit Timestamp="2025-06-04T14:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="110547SF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="110548SF" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAUGHCHA" b2="230 KV" b3="230-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="230-2OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="230-2_28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="2_3BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="540-2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57250</SeqNum>
    <Name>230/115.WaughChapel.T3</Name>
    <LastEdit Timestamp="2025-06-04T14:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="110545SF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="110546SF" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAUGHCHA" b2="230 KV" b3="230-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="230-3OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="230-3_43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="32TIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57290</SeqNum>
    <Name>230/69.Harwood.T6</Name>
    <LastEdit Timestamp="2025-11-25T16:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HARWOOD" b2="230 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="230 KV" b3="TRAN6N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="230 KV" b3="TRAN6S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="69 KV" b3="TRAN6_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="69 KV" b3="TRAN6_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57300</SeqNum>
    <Name>500/230.Alburtis.T1</Name>
    <LastEdit Timestamp="2025-12-30T13:51:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBURTIS" b2="230 KV" b3="ALB-ALB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALBURTIS" b2="500 KV" b3="TR 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTIS" b2="500 KV" b3="TRAN_1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTME" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTME" b2="230 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57390</SeqNum>
    <Name>230/69.Quarry.T1</Name>
    <LastEdit Timestamp="2024-11-27T09:21:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="QUARRY" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="230 KV" b3="TRAN1_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="69 KV" b3="TRAN1_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="69 KV" b3="TRAN1_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57410</SeqNum>
    <Name>230/138.Siegfried.T4</Name>
    <LastEdit Timestamp="2024-12-03T14:01:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SIEGFRIE" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="TRAN4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="138 KV" b3="TRAN_4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57420</SeqNum>
    <Name>230/138.Siegfried.T5</Name>
    <LastEdit Timestamp="2024-12-03T14:00:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SIEGFRIE" b2="230 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="TRAN5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="138 KV" b3="TRAN_5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57440</SeqNum>
    <Name>230/138.SouthAkron.T6 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-08-30T14:28:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SAKRON" b2="230 KV" b3="6" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SAKRON" b2="230 KV" b3="CAP4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="CAP4 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SAKRON" b2="230 KV" b3="TRAN6MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="138 KV" b3="TRAN_6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57450</SeqNum>
    <Name>230/138.SouthAkron.T7 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SAKRON" b2="230 KV" b3="7" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SAKRON" b2="230 KV" b3="CAP3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="CAP_3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SAKRON" b2="230 KV" b3="TRAN7MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="138 KV" b3="TRAN_7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57470</SeqNum>
    <Name>500/230.Susquehanna.T21</Name>
    <LastEdit Timestamp="2025-07-07T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SUSQUEHA" b2="500 KV" b3="21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="500 KV" b3="TR21HICB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="TR_BK_21" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57480</SeqNum>
    <Name>138/69.Wescosville.T1</Name>
    <LastEdit Timestamp="2024-09-19T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WESCOSVI" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="138 KV" b3="TRAN1_HI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57490</SeqNum>
    <Name>230/138.WestHempfield.T3</Name>
    <LastEdit Timestamp="2025-07-22T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WHEMPFIE" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="230 KV" b3="TRAN3HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="138 KV" b3="TRAN_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57500</SeqNum>
    <Name>230/69.Jenkins.T4</Name>
    <LastEdit Timestamp="2024-06-21T12:54:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="JENKINS" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="230 KV" b3="MOUNEAST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="230 KV" b3="PALO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="230 KV" b3="TRAN2E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="TRAN4_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="TRAN4_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57510</SeqNum>
    <Name>230/69.Lackawanna.T1</Name>
    <LastEdit Timestamp="2025-11-10T11:21:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LACKAWAN" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="SUMIT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="SUMIT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="TRAN3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="TRAN4_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57520</SeqNum>
    <Name>230/69.Lackawanna.T2</Name>
    <LastEdit Timestamp="2025-11-10T11:15:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LACKAWAN" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="LAENRGY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="NMESH_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="PAUPACK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="TRAN4_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57570</SeqNum>
    <Name>500/230.SteelCity.T1</Name>
    <LastEdit Timestamp="2024-06-21T13:10:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELCTY" b2="500 KV" b3="BEPO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELCTY" b2="500 KV" b3="HOSE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELCTY" b2="230 KV" b3="QUAR1_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELCTY" b2="230 KV" b3="QUAR2" />
      <ContingencyEquipment Action="X" Type="XF" b1="STEELCTY" b2="500 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57610</SeqNum>
    <Name>L138.Cecil-Houston-Nyswaner</Name>
    <LastEdit Timestamp="2025-01-10T12:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CECI APS" b2="138 KV" b3="CEC-HOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CECI APS" b2="138 KV" b3="HOUSTON" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HOUSTON" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NYSWANER" b2="138 KV" b3="NYS-HOU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOUSTON" b2="138 KV" b3="T2A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOUSTON" b2="138 KV" b3="T2B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOUSTON" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOUSTON" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NYSWANER" b2="138 KV" b3="HOUSTON" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57620</SeqNum>
    <Name>L138.Nyswaner-Manifold-Perryman-Gordon</Name>
    <LastEdit Timestamp="2025-04-01T14:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GORDON" b2="138 KV" b3="GOR-PERR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDON" b2="138 KV" b3="MANIFOLD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MANIFOLD" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NYSWANER" b2="138 KV" b3="NYS-MAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MANIFOLD" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MANIFOLD" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NYSWANER" b2="138 KV" b3="MANIFOLD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANIFOLD" b2="138 KV" b3="MAN-PERR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PERRYMA1" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57690</SeqNum>
    <Name>L230.Balston-Clarendon.2096</Name>
    <LastEdit Timestamp="2024-05-31T08:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLARENDN" b2="230 KV" b3="2096" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALSTON" b2="230 KV" b3="20962142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARENDN" b2="230 KV" b3="277T2096" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARENDN" b2="230 KV" b3="278T2096" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>57800</SeqNum>
    <Name>L115.EagleValley-Philipsburg</Name>
    <LastEdit Timestamp="2024-05-31T08:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLEVAL" b2="115 KV" b3="1137-B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLEVAL" b2="115 KV" b3="1137-B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EAGLEVAL" b2="115 KV" b3="EAG-PHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHILIPSB" b2="115 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58060</SeqNum>
    <Name>L345.Arcadian-Pleasant Prairie (WEC)</Name>
    <LastEdit Timestamp="2024-09-05T14:57:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARCADIAN" b2="345 KV" b3="9276" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARCADIAN" b2="345 KV" b3="9277" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARCADIAN" b2="345 KV" b3="ARC-PLE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEAS PR" b2="345 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEAS PR" b2="345 KV" b3="8-7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58090</SeqNum>
    <Name>L138.AllenJunction-Silica-Lyons-Fayet-EastFayette</Name>
    <LastEdit Timestamp="2025-02-18T15:45:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02FAYET" b2="138 KV" b3="02F-EFY" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02FAYET" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LYONS" b2="138 KV" b3="02L-02F1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02LYONS" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02SILICA" b2="138 KV" b3="A13153" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENJUN" b2="138 KV" b3="ALL-SILI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="138 KV" b3="B13373" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E_FAYET" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E_FAYET" b2="138 KV" b3="B78" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LYONS" b2="138 KV" b3="02L-SILI" />
      <ContingencyEquipment Action="L" Type="LN" b1="02SILICA" b2="138 KV" b3="02S-SILI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58110</SeqNum>
    <Name>L138.EastFayette-Stryker</Name>
    <LastEdit Timestamp="2024-05-31T08:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="E_FAYET" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E_FAYET" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRYKER" b2="138 KV" b3="3221" />
      <ContingencyEquipment Action="L" Type="LN" b1="STRYKER" b2="138 KV" b3="STR-EFAY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58200</SeqNum>
    <Name>L138.Hamilton-Horizon.Q1</Name>
    <LastEdit Timestamp="2025-12-23T07:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02HAMLTN" b2="138 KV" b3="B13" />
      <ContingencyEquipment Action="L" Type="LN" b1="02HAMLTN" b2="138 KV" b3="02H-HOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON1" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58210</SeqNum>
    <Name>L138.Hamilton-Horizon.Q2</Name>
    <LastEdit Timestamp="2025-12-23T07:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02HAMLTN" b2="138 KV" b3="B15" />
      <ContingencyEquipment Action="L" Type="LN" b1="02HAMLTN" b2="138 KV" b3="02H-HOR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON1" b2="138 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58220</SeqNum>
    <Name>230/115.NorthernNeck.TX6</Name>
    <LastEdit Timestamp="2024-06-03T08:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="230 KV" b3="H652" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="115 KV" b3="L652" />
      <ContingencyEquipment Action="X" Type="XF" b1="NRTHNECK" b2="230 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58230</SeqNum>
    <Name>L230.NrthWales-Centerpoint.220-92+230/35.NWales.T2</Name>
    <LastEdit Timestamp="2024-06-10T16:16:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTERPT" b2="230 KV" b3="675" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTERPT" b2="230 KV" b3="CEN-NWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWALES" b2="35 KV" b3="40 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWALES" b2="230 KV" b3="805 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="NWALES" b2="230 KV" b3="NW 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58240</SeqNum>
    <Name>L230.UpperProvidence-Perkiomen-Centerpoint.220-79</Name>
    <LastEdit Timestamp="2024-06-10T16:17:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTERPT" b2="230 KV" b3="565" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTERPT" b2="230 KV" b3="CEN-PER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERKIOME" b2="35 KV" b3="665 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PERKIOME" b2="230 KV" b3="PER 6TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="PERKIOME" b2="230 KV" b3="PER-UPP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERPRO" b2="230 KV" b3="725" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58320</SeqNum>
    <Name>L230.Penrose-GraysFerry-Peltz.220-95</Name>
    <LastEdit Timestamp="2026-03-27T10:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="755_CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GRAYSFER" b2="230 KV" b3="8-1_CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="815 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYSFER" b2="230 KV" b3="GRA-PEL2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYSFER" b2="230 KV" b3="GRA-PEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PELTZ" b2="230 KV" b3="955" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENROSE" b2="230 KV" b3="105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENROSE" b2="230 KV" b3="905" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58330</SeqNum>
    <Name>L230.GraysFerry-Peltz.220-94</Name>
    <LastEdit Timestamp="2024-06-03T11:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSFER" b2="230 KV" b3="905 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYSFER" b2="230 KV" b3="GRA-PEL1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PELTZ" b2="230 KV" b3="4 TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PELTZ" b2="13 KV" b3="45 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PELTZ" b2="230 KV" b3="875" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58350</SeqNum>
    <Name>230/13.Peltz.T5</Name>
    <LastEdit Timestamp="2025-09-05T11:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PELTZ" b2="230 KV" b3="5 TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PELTZ" b2="13 KV" b3="55 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PELTZ" b2="230 KV" b3="875" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PELTZ" b2="230 KV" b3="975" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58360</SeqNum>
    <Name>L138.MahansLane-Tidd</Name>
    <LastEdit Timestamp="2024-06-03T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAHANSLA" b2="138 KV" b3="202 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAHANSLA" b2="138 KV" b3="MAH-TID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="C_4E38F3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58370</SeqNum>
    <Name>L138.LakeRd-EIndustrial</Name>
    <LastEdit Timestamp="2024-11-15T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02LAKERD" b2="138 KV" b3="02L-02E2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="02E_IND" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02E_IND" b2="138 KV" b3="CS-CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02E_IND" b2="138 KV" b3="CS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02E_IND" b2="138 KV" b3="EI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02E_IND" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LAKERD" b2="138 KV" b3="CB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LAKERD" b2="138 KV" b3="CB4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58380</SeqNum>
    <Name>L138.LakeRd-Divisional</Name>
    <LastEdit Timestamp="2024-06-10T16:15:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02LAKERD" b2="138 KV" b3="02L-02D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DIVISN" b2="138 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DIVISN" b2="138 KV" b3="CB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DIVISN" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02DIVISN" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="02LAKERD" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LAKERD" b2="138 KV" b3="CB3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LAKERD" b2="138 KV" b3="CB4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LAKERD" b2="138 KV" b3="CS-CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58390</SeqNum>
    <Name>DTX138.LakeRoad.69KVLOAD</Name>
    <LastEdit Timestamp="2024-10-23T13:28:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02LAKERD" b2="138 KV" b3="69KVLOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LAKERD" b2="138 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LAKERD" b2="138 KV" b3="CB5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58400</SeqNum>
    <Name>L138.Southeast-EIndustrial</Name>
    <LastEdit Timestamp="2024-11-15T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02E_IND" b2="138 KV" b3="02E-02S1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02E_IND" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02E_IND" b2="138 KV" b3="EI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02E_IND" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02S_EAST" b2="138 KV" b3="CS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02S_EAST" b2="138 KV" b3="SE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02S_EAST" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58410</SeqNum>
    <Name>L138.Nottingham-Collingwood</Name>
    <LastEdit Timestamp="2024-11-15T15:25:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02COLLIN" b2="138 KV" b3="02C-02C5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02COLLIN" b2="138 KV" b3="CD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02COLLIN" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02CPP_NH" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02CPP_NH" b2="138 KV" b3="NG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02CPP_NH" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58420</SeqNum>
    <Name>L138.Northeast-NineMile</Name>
    <LastEdit Timestamp="2024-06-03T12:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="02N_EAST" b2="138 KV" b3="DS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NINEMILE" b2="138 KV" b3="NIN-NOR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NINEMILE" b2="138 KV" b3="NMNE-DS2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58430</SeqNum>
    <Name>L138.Northeast-Medc</Name>
    <LastEdit Timestamp="2024-11-18T13:00:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02N_EAST" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="02N_EAST" b2="138 KV" b3="MED-EAS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02N_EAST" b2="138 KV" b3="NE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02N_EAST" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_MEDC" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_MEDC" b2="138 KV" b3="CSA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CPP_MEDC" b2="138 KV" b3="TRA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58440</SeqNum>
    <Name>L138.Medc-East</Name>
    <LastEdit Timestamp="2024-06-03T12:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="CPP_EAST" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_EAST" b2="138 KV" b3="CS-CAP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CPP_EAST" b2="138 KV" b3="DS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CPP_MEDC" b2="138 KV" b3="MED-EAS2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CPP_MEDC" b2="138 KV" b3="ET" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58450</SeqNum>
    <Name>L138.East-Pofok</Name>
    <LastEdit Timestamp="2024-11-15T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_EAST" b2="138 KV" b3="CS1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CPP_EAST" b2="138 KV" b3="EAS-HOLT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_EAST" b2="138 KV" b3="ET" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CPP_EAST" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_GPFK" b2="138 KV" b3="CB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_GPFK" b2="138 KV" b3="CB3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58460</SeqNum>
    <Name>L138.Pofok-Southeast</Name>
    <LastEdit Timestamp="2024-11-15T11:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02S_EAST" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02S_EAST" b2="138 KV" b3="SE" />
      <ContingencyEquipment Action="L" Type="LN" b1="02S_EAST" b2="138 KV" b3="SEAS-HOL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02S_EAST" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_GPFK" b2="138 KV" b3="CB3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_GPFK" b2="138 KV" b3="CB4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58470</SeqNum>
    <Name>L138.Inland-Pofok.Q22 </Name>
    <LastEdit Timestamp="2025-07-08T14:08:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_GPFK" b2="138 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_GPFK" b2="138 KV" b3="CB2" />
      <ContingencyEquipment Action="L" Type="LN" b1="INLAND" b2="138 KV" b3="INL-HOLT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="138 KV" b3="Q24_IN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58480</SeqNum>
    <Name>138/69.W41ST.T1</Name>
    <LastEdit Timestamp="2024-06-10T16:14:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="04CPPW41" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="04CPPW41" b2="69 KV" b3="69KVLOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="04CPPW41" b2="138 KV" b3="CS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58490</SeqNum>
    <Name>L138.Division-West41st</Name>
    <LastEdit Timestamp="2025-06-24T13:13:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02DIVISN" b2="138 KV" b3="02D-04C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DIVISN" b2="138 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DIVISN" b2="138 KV" b3="CB4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DIVISN" b2="138 KV" b3="CS1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02DIVISN" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="04CPPW41" b2="138 KV" b3="CB2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58500</SeqNum>
    <Name>L138.RidgeRoad-West41st</Name>
    <LastEdit Timestamp="2025-06-26T11:45:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="04CPPW41" b2="138 KV" b3="04C-RID1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="04CPPW41" b2="138 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_RIDG" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_RIDG" b2="138 KV" b3="RGCB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_RIDG" b2="138 KV" b3="RGCB2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CPP_RIDG" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58710</SeqNum>
    <Name>L138.Pierce-Beckjord.4 + 345/138.Pierce.17</Name>
    <LastEdit Timestamp="2025-10-14T18:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="822" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="922" />
      <ContingencyEquipment Action="L" Type="LN" b1="BECKJORD" b2="138 KV" b3="PIE-BEC4" />
      <ContingencyEquipment Action="X" Type="XF" b1="PIERC_DK" b2="345 KV" b3="BK17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERC_DK" b2="345 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERC_DK" b2="345 KV" b3="R" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58720</SeqNum>
    <Name>L138.Potter-Raccoon.Z-83</Name>
    <LastEdit Timestamp="2024-06-03T09:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="POTTERSS" b2="138 KV" b3="POT-RAC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE7-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE8-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RACC DUQ" b2="138 KV" b3="Z-83" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58810</SeqNum>
    <Name>L345.Babcock-Stillwell (NIPS)</Name>
    <LastEdit Timestamp="2026-05-11T15:44:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABCOCK" b2="345 KV" b3="1423" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABCOCK" b2="345 KV" b3="214" />
      <ContingencyEquipment Action="L" Type="LN" b1="BABCOCK" b2="345 KV" b3="BAB-STI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STILLWEL" b2="345 KV" b3="14-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STILLWEL" b2="345 KV" b3="14-W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>58830</SeqNum>
    <Name>L138.Mahomet-Lever-NChampaign-Rising</Name>
    <LastEdit Timestamp="2024-11-18T13:22:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="RISING" b2="138 KV" b3="1592" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAMP T3" b2="138 KV" b3="1592   2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAMP T3" b2="138 KV" b3="32396323" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEVER R3" b2="138 KV" b3="TR1 LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEVER R3" b2="138 KV" b3="TR2 LD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MAHOMET" b2="138 KV" b3="DUM2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEVER R3" b2="138 KV" b3="32399324" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NCHAMPGN" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NCHAMPGN" b2="138 KV" b3="H11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="138 KV" b3="H11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="138 KV" b3="H9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59050</SeqNum>
    <Name>L138.EastLake-Liberty-Progressive-Keith-LLoyd.Q12</Name>
    <LastEdit Timestamp="2025-12-26T13:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02LARK" b2="138 KV" b3="02L-KEP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PROGINS" b2="138 KV" b3="PRO-02L1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="02LARK" b2="138 KV" b3="SW323" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LARK" b2="138 KV" b3="SWR232" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LBRTY" b2="138 KV" b3="02L-LAM2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTLAKE" b2="138 KV" b3="EAS-02L1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B32" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENYON" b2="138 KV" b3="KEN-KEI2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEITH" b2="138 KV" b3="SW264" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KENYON" b2="138 KV" b3="SW313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENYON" b2="138 KV" b3="SWR124" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEPLER" b2="138 KV" b3="KEP-KEN1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KEPLER" b2="138 KV" b3="SW323" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEPLER" b2="138 KV" b3="SWR228" />
      <ContingencyEquipment Action="L" Type="LN" b1="LLOYD" b2="138 KV" b3="LLO-LAM2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LAMONT" b2="138 KV" b3="SW313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMONT" b2="138 KV" b3="SWR232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLOYD" b2="138 KV" b3="Q2_T" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LLOYD" b2="138 KV" b3="SW25" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LBRTY" b2="138 KV" b3="02L-PR2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PROGINS" b2="138 KV" b3="LB17" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PROGINS" b2="138 KV" b3="LB18" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59060</SeqNum>
    <Name>345/138.MattFunk.T1</Name>
    <LastEdit Timestamp="2024-06-03T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MATTFUN2" b2="345 KV" b3=".  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="G1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59090</SeqNum>
    <Name>L138.Pursley-Franklin</Name>
    <LastEdit Timestamp="2024-06-04T11:14:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FRAN APS" b2="138 KV" b3="FRA-PUR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FRAN APS" b2="138 KV" b3="PURSLEY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PURSLEY" b2="138 KV" b3="FRANKLIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59130</SeqNum>
    <Name>345/138.116GoodingsGrove.TR82</Name>
    <LastEdit Timestamp="2024-12-03T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="116 GOOD" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="116 GOOD" b2="138 KV" b3="TR82CT-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="TR82HSCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59140</SeqNum>
    <Name>L500.Centerpoint-Elroy.5033</Name>
    <LastEdit Timestamp="2024-06-03T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTERPT" b2="500 KV" b3="125" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTERPT" b2="500 KV" b3="235" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTERPT" b2="500 KV" b3="CEN-ELR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROY" b2="500 KV" b3="145 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROY" b2="500 KV" b3="155 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59150</SeqNum>
    <Name>L500.Centerpoint-Whitpain.5029</Name>
    <LastEdit Timestamp="2024-06-03T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTERPT" b2="500 KV" b3="125" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTERPT" b2="500 KV" b3="135" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTERPT" b2="500 KV" b3="CEN-WHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="500 KV" b3="635" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="500 KV" b3="675 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59160</SeqNum>
    <Name>500/230.Centerpoint.1TR</Name>
    <LastEdit Timestamp="2024-06-03T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTERPT" b2="500 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTERPT" b2="230 KV" b3="165" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTERPT" b2="500 KV" b3="235" />
      <ContingencyEquipment Action="X" Type="XF" b1="CENTERPT" b2="500 KV" b3="CEN 1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59170</SeqNum>
    <Name>500/230.Whitpain.3TR</Name>
    <LastEdit Timestamp="2024-06-03T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="230 KV" b3="335 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="500 KV" b3="385 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITPAIN" b2="500 KV" b3="635" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHITPAIN" b2="500 KV" b3="WHT 3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59180</SeqNum>
    <Name>345/138.Brokaw.45TR2 (AMRN)</Name>
    <LastEdit Timestamp="2025-11-25T16:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="345 KV" b3="4543" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="345 KV" b3="4546" />
      <ContingencyEquipment Action="X" Type="XF" b1="BROKAW" b2="345 KV" b3="45TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="138 KV" b3="H15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="138 KV" b3="H25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="138 KV" b3="H35" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59220</SeqNum>
    <Name>L230.Forest-Glade</Name>
    <LastEdit Timestamp="2025-10-16T13:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOREST" b2="230 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOREST" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLADE" b2="230 KV" b3="FOR-GLA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLADE" b2="230 KV" b3="B42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLADE" b2="230 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59240</SeqNum>
    <Name>L138.PotterSS-Raccoon.Z-81</Name>
    <LastEdit Timestamp="2025-03-27T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="POTTERSS" b2="138 KV" b3="POT-RAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE6-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE7-6CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RACC DUQ" b2="138 KV" b3="Z-81" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59250</SeqNum>
    <Name>161/69.GreenCounty.XF1811</Name>
    <LastEdit Timestamp="2025-05-20T11:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCO" b2="69 KV" b3="BW45_648" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCO" b2="161 KV" b3="CB1038" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENCO" b2="161 KV" b3="XF1811" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59260</SeqNum>
    <Name>L345.Terminal-PortUnion.4513</Name>
    <LastEdit Timestamp="2024-06-03T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="345 KV" b3="1373" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="345 KV" b3="1375" />
      <ContingencyEquipment Action="L" Type="LN" b1="PORTUNIO" b2="345 KV" b3="POR-TER1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="345 KV" b3="1303" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="345 KV" b3="1305" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59270</SeqNum>
    <Name>L345.Foster-PortUnion.4508</Name>
    <LastEdit Timestamp="2024-06-03T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="345 KV" b3="1353" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="345 KV" b3="1359" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="345 KV" b3="1365" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="345 KV" b3="1369" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTER2" b2="345 KV" b3="FOS-POR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59280</SeqNum>
    <Name>L345.Hillcrest-Stuart</Name>
    <LastEdit Timestamp="2024-06-03T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILCRST2" b2="345 KV" b3="1423" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILCRST2" b2="345 KV" b3="1427" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILCRST2" b2="345 KV" b3="HIL-STU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUART2" b2="345 KV" b3="JJ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUART2" b2="345 KV" b3="KK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59290</SeqNum>
    <Name>L345.MiamiFort-Terminal.4514</Name>
    <LastEdit Timestamp="2024-10-18T13:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1417" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1418" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="345 KV" b3="1301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="345 KV" b3="1303" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIAMIFOR" b2="345 KV" b3="MIA-TER1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59310</SeqNum>
    <Name>L345.Zimmer-SilverGrove-RedBank + SilverGrove.T24</Name>
    <LastEdit Timestamp="2025-09-04T14:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBANK" b2="345 KV" b3="1487" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBANK" b2="345 KV" b3="1493" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDBANK" b2="345 KV" b3="RED-SIL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERGR" b2="345 KV" b3="1416" />
      <ContingencyEquipment Action="X" Type="XF" b1="SILVERGR" b2="345 KV" b3="24" />
      <ContingencyEquipment Action="L" Type="LN" b1="SILVERGR" b2="345 KV" b3="SIL-ZIM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZIMMER2" b2="345 KV" b3="1441" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZIMMER2" b2="345 KV" b3="1447" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59320</SeqNum>
    <Name>L345.RedBank-Terminal</Name>
    <LastEdit Timestamp="2024-06-10T16:15:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBANK" b2="345 KV" b3="1489" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBANK" b2="345 KV" b3="1491" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="345 KV" b3="1309" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="345 KV" b3="1311" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDBANK" b2="345 KV" b3="RED-TER1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59330</SeqNum>
    <Name>L345.Todhunter-Woodsdale1.4561</Name>
    <LastEdit Timestamp="2025-08-21T13:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="345 KV" b3="1381" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="345 KV" b3="1383" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="345 KV" b3="1517" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="345 KV" b3="1519" />
      <ContingencyEquipment Action="L" Type="LN" b1="TODDHUNT" b2="345 KV" b3="TOD-WOO1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59340</SeqNum>
    <Name>L345.Todhunter-Woodsdale2.4562</Name>
    <LastEdit Timestamp="2025-08-21T13:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="345 KV" b3="1389" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="345 KV" b3="1391" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="345 KV" b3="1511" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="345 KV" b3="1513" />
      <ContingencyEquipment Action="L" Type="LN" b1="TODDHUNT" b2="345 KV" b3="TOD-WOO2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59350</SeqNum>
    <Name>L345.MiamiFort-Woodsdale.4592</Name>
    <LastEdit Timestamp="2025-08-21T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1407" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1409" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="345 KV" b3="1505" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="345 KV" b3="1507" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIAMIFOR" b2="345 KV" b3="MIA-WOO1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59360</SeqNum>
    <Name>L345.Woodsdale-Madison+Madison.CTs</Name>
    <LastEdit Timestamp="2025-08-21T13:02:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON1" b2="345 KV" b3="1601" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON1" b2="345 KV" b3="1602" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON1" b2="345 KV" b3="1603" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON1" b2="345 KV" b3="1604" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MADISON1" b2="13.8 KV" b3="CT-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MADISON1" b2="13.8 KV" b3="CT-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MADISON1" b2="13.8 KV" b3="CT-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MADISON1" b2="13.8 KV" b3="CT-4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MADISON1" b2="13.8 KV" b3="CT-5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MADISON1" b2="13.8 KV" b3="CT-6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MADISON1" b2="13.8 KV" b3="CT-7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MADISON1" b2="13.8 KV" b3="CT-8" />
      <ContingencyEquipment Action="X" Type="XF" b1="MADISON1" b2="345 KV" b3="TB1_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="MADISON1" b2="13.8 KV" b3="TB1_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="MADISON1" b2="13.8 KV" b3="TB1_T" />
      <ContingencyEquipment Action="X" Type="XF" b1="MADISON1" b2="345 KV" b3="TB2_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="MADISON1" b2="13.8 KV" b3="TB2_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="MADISON1" b2="13.8 KV" b3="TB2_T" />
      <ContingencyEquipment Action="X" Type="XF" b1="MADISON1" b2="345 KV" b3="TB3_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="MADISON1" b2="13.8 KV" b3="TB3_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="MADISON1" b2="13.8 KV" b3="TB3_T" />
      <ContingencyEquipment Action="X" Type="XF" b1="MADISON1" b2="345 KV" b3="TB4_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="MADISON1" b2="13.8 KV" b3="TB4_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="MADISON1" b2="13.8 KV" b3="TB4_T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="345 KV" b3="1519" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="345 KV" b3="1521" />
      <ContingencyEquipment Action="L" Type="LN" b1="WOODSDAL" b2="345 KV" b3="MAD-WOO2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59370</SeqNum>
    <Name>L138.MiamiFort-Greendale</Name>
    <LastEdit Timestamp="2025-06-25T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="08GRDALE" b2="138 KV" b3="138-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIAMIFOR" b2="138 KV" b3="MIA-08G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="807" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59380</SeqNum>
    <Name>138/69.MiamiFort.TB18 + CT3-6</Name>
    <LastEdit Timestamp="2025-09-02T10:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="13.2 KV" b3="433" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="13.2 KV" b3="444" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="13.2 KV" b3="455" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="13.2 KV" b3="466" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="824_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="830" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MIAMIFOR" b2="13.2 KV" b3="CT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MIAMIFOR" b2="13.2 KV" b3="CT4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MIAMIFOR" b2="13.2 KV" b3="CT5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MIAMIFOR" b2="13.2 KV" b3="CT6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIAMIFOR" b2="13.2 KV" b3="TB10" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIAMIFOR" b2="138 KV" b3="TB18_1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIAMIFOR" b2="13.2 KV" b3="TB18_2" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIAMIFOR" b2="13.2 KV" b3="TB18_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59390</SeqNum>
    <Name>L138.Elmwood-Lateral</Name>
    <LastEdit Timestamp="2026-05-07T11:36:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08EMWOD1" b2="138 KV" b3="807" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EMWOD1" b2="138 KV" b3="810" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EMWOD1" b2="138 KV" b3="815" />
      <ContingencyEquipment Action="L" Type="LN" b1="08EMWOD1" b2="138 KV" b3="08E-08L1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LATERAL" b2="138 KV" b3="842" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59400</SeqNum>
    <Name>138/69.Elmwood.BK6</Name>
    <LastEdit Timestamp="2026-05-11T08:55:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08EMWOD1" b2="138 KV" b3="810" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EMWOD1" b2="138 KV" b3="812" />
      <ContingencyEquipment Action="X" Type="XF" b1="08EMWOD1" b2="138 KV" b3="BK6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EMWOD1" b2="69 KV" b3="CB736" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EMWOD1" b2="69 KV" b3="CB744" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59410</SeqNum>
    <Name>L138.RedBank-Oakley</Name>
    <LastEdit Timestamp="2025-01-03T14:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="138 KV" b3="803" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="138 KV" b3="804" />
      <ContingencyEquipment Action="L" Type="LN" b1="08OAKLEY" b2="138 KV" b3="08O-RED1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBANK" b2="138 KV" b3="916" />
      <ContingencyEquipment Action="S" Type="SD" b1="REDBANK" b2="138 KV" b3="F-885" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59420</SeqNum>
    <Name>L138.Oakley-Beckjord-Summerside</Name>
    <LastEdit Timestamp="2024-11-13T13:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="088MIRDJ" b2="138 KV" b3="088-08OA" />
      <ContingencyEquipment Action="L" Type="LN" b1="088MIRDJ" b2="138 KV" b3="088-08SM" />
      <ContingencyEquipment Action="L" Type="LN" b1="088MIRDJ" b2="138 KV" b3="088-BECK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="138 KV" b3="814" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="138 KV" b3="815" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08SMRSD1" b2="138 KV" b3="850" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08SMRSD1" b2="138 KV" b3="851" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="911" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59430</SeqNum>
    <Name>L138.Terminal-Henkel-Mitchell</Name>
    <LastEdit Timestamp="2024-06-04T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HENKEL" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HENKEL" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HENKEL" b2="138 KV" b3="HEN-TER" />
      <ContingencyEquipment Action="L" Type="LN" b1="HENKEL" b2="138 KV" b3="08E-MIT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHCGE" b2="138 KV" b3="837" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="138 KV" b3="908" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59440</SeqNum>
    <Name>L138.CampWash-MetroSewer-Queensgate-WestEnd.1581</Name>
    <LastEdit Timestamp="2025-05-29T13:24:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMP_WSH" b2="138 KV" b3="811" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMP_WSH" b2="138 KV" b3="815" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMP_WSH" b2="138 KV" b3="CAM-METR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAMP_WSH" b2="138 KV" b3="TB1" />
      <ContingencyEquipment Action="L" Type="LN" b1="METR_SEW" b2="138 KV" b3="08M-08Q1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="METR_SEW" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="METR_SEW" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="QUEENSG" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="QUEENSG" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="QUEENSG" b2="138 KV" b3="08Q-WEN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="915" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="917" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59450</SeqNum>
    <Name>L138.Central-Mitchell</Name>
    <LastEdit Timestamp="2024-06-04T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08CNTRAL" b2="138 KV" b3="924" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08CNTRAL" b2="138 KV" b3="926" />
      <ContingencyEquipment Action="L" Type="LN" b1="MITCHCGE" b2="138 KV" b3="CEN-MIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHCGE" b2="138 KV" b3="831" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59460</SeqNum>
    <Name>L138.Charles-WestEnd.1385</Name>
    <LastEdit Timestamp="2024-06-04T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLES" b2="138 KV" b3="08C-WEN3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLES" b2="138 KV" b3="907" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLES" b2="138 KV" b3="909" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="945" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="947" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59470</SeqNum>
    <Name>L138.Charles-WestEnd.1389</Name>
    <LastEdit Timestamp="2024-06-04T15:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLES" b2="138 KV" b3="08C-WEN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLES" b2="138 KV" b3="911" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLES" b2="138 KV" b3="913" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="919" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="923" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59480</SeqNum>
    <Name>L138.WestEnd-Crescent.1587</Name>
    <LastEdit Timestamp="2024-11-08T12:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRESCNT" b2="138 KV" b3="08C-WEN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESCNT" b2="138 KV" b3="853" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESCNT" b2="138 KV" b3="860" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="927" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="929" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59490</SeqNum>
    <Name>L138.MiamiFort-Morgan</Name>
    <LastEdit Timestamp="2025-05-28T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="915" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="930" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MRGAN" b2="138 KV" b3="951" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MRGAN" b2="138 KV" b3="956" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIAMIFOR" b2="138 KV" b3="MIA-08M2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59500</SeqNum>
    <Name>L138.Terminal-Glenview</Name>
    <LastEdit Timestamp="2024-06-04T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GLNVIEW" b2="138 KV" b3="08G-TER1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLNVIEW" b2="138 KV" b3="853" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="138 KV" b3="903" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59510</SeqNum>
    <Name>L138.Terminal-TP1783-Ebenezer</Name>
    <LastEdit Timestamp="2025-01-27T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08EBNZR5" b2="138 KV" b3="955" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EBNZR5" b2="138 KV" b3="957" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDWAY2" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="138 KV" b3="914" />
      <ContingencyEquipment Action="L" Type="LN" b1="08EBNZR5" b2="138 KV" b3="08E-08M1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TP1783" b2="138 KV" b3="08M-TER1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TP1783" b2="138 KV" b3="MID-TP17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59520</SeqNum>
    <Name>L138.Beckjord-Silver Grove</Name>
    <LastEdit Timestamp="2024-06-04T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="801" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERGR" b2="138 KV" b3="811" />
      <ContingencyEquipment Action="L" Type="LN" b1="SILVERGR" b2="138 KV" b3="BEC-SIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59530</SeqNum>
    <Name>L138.Beckjord-Wilder</Name>
    <LastEdit Timestamp="2025-11-19T14:23:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08WLDER1" b2="138 KV" b3="838" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08WLDER1" b2="138 KV" b3="LD5" />
      <ContingencyEquipment Action="L" Type="LN" b1="08WLDER1" b2="138 KV" b3="08W-PIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="823" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59540</SeqNum>
    <Name>L138.Beckjord-Newton-RedBank</Name>
    <LastEdit Timestamp="2026-01-02T11:16:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="903" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWTWN" b2="138 KV" b3="08N-RED1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BECKJORD" b2="138 KV" b3="BEC-08N1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWTWN" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWTWN" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWTWN" b2="138 KV" b3="BK3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBANK" b2="138 KV" b3="917" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59550</SeqNum>
    <Name>L138.Beckjord-Tobasco</Name>
    <LastEdit Timestamp="2024-06-04T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08TBSCO1" b2="138 KV" b3="860" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08TBSCO1" b2="138 KV" b3="866" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08TBSCO1" b2="138 KV" b3="BK4" />
      <ContingencyEquipment Action="L" Type="LN" b1="08TBSCO1" b2="138 KV" b3="08T-PIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="805" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59560</SeqNum>
    <Name>L138.Ford Batavia-Cedarville</Name>
    <LastEdit Timestamp="2024-06-04T15:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARVIL" b2="138 KV" b3="977" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARVIL" b2="138 KV" b3="CED-08F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORD_BAT" b2="138 KV" b3="915" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORD_BAT" b2="138 KV" b3="920" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59570</SeqNum>
    <Name>L138.Todhunter-Trenton</Name>
    <LastEdit Timestamp="2024-06-04T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="919" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="921" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON2" b2="138 KV" b3="806" />
      <ContingencyEquipment Action="L" Type="LN" b1="TODDHUNT" b2="138 KV" b3="TOD-TRE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59590</SeqNum>
    <Name>L138.PortUnion-Provident-Hall-Fairfield.3885</Name>
    <LastEdit Timestamp="2025-10-29T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08FRFLD1" b2="138 KV" b3="881" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08FRFLD1" b2="138 KV" b3="884" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08FRFLD1" b2="138 KV" b3="BK6" />
      <ContingencyEquipment Action="L" Type="LN" b1="08FRFLD1" b2="138 KV" b3="08F-08H1" />
      <ContingencyEquipment Action="L" Type="LN" b1="08HALL1" b2="138 KV" b3="08H-PROV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08HALL1" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08HALL1" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="138 KV" b3="902" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PROVIDNT" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PROVIDNT" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PORTUNIO" b2="138 KV" b3="POR-PROV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59600</SeqNum>
    <Name>L138.Fairfield-Mulhausur-PortUnion.3886</Name>
    <LastEdit Timestamp="2024-09-19T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="08FRFLD1" b2="138 KV" b3="08L-MULH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08FRFLD1" b2="138 KV" b3="884" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08FRFLD1" b2="138 KV" b3="886" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08FRFLD1" b2="138 KV" b3="BK4" />
      <ContingencyEquipment Action="L" Type="LN" b1="MULHAUSR" b2="138 KV" b3="08M-POR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MULHAUSR" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MULHAUSR" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MULHAUSR" b2="138 KV" b3="BK4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="138 KV" b3="801" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59610</SeqNum>
    <Name>L138.PortUnion-Millikin-Todhunter.3887</Name>
    <LastEdit Timestamp="2025-10-20T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MILLIKIN" b2="138 KV" b3="08M-POR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLIKIN" b2="138 KV" b3="08M-TOD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLIKIN" b2="138 KV" b3="947" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLIKIN" b2="138 KV" b3="954" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILLIKIN" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILLIKIN" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="138 KV" b3="911" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="929" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="931" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59620</SeqNum>
    <Name>L138.PortUnion-Seward-Hamilton.3889</Name>
    <LastEdit Timestamp="2025-10-16T13:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08HAMLTN" b2="138 KV" b3="931" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08HAMLTN" b2="138 KV" b3="938" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="138 KV" b3="809" />
      <ContingencyEquipment Action="L" Type="LN" b1="08HAMLTN" b2="138 KV" b3="08H-SEW" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWARD" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWARD" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWARD" b2="138 KV" b3="BK3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWARD" b2="138 KV" b3="BK4" />
      <ContingencyEquipment Action="L" Type="LN" b1="SWARD" b2="138 KV" b3="SEW-POR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59630</SeqNum>
    <Name>L138.Red Bank-Lateral</Name>
    <LastEdit Timestamp="2024-06-04T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LATERAL" b2="138 KV" b3="08L-RED1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LATERAL" b2="138 KV" b3="837" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBANK" b2="138 KV" b3="924" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59640</SeqNum>
    <Name>L138.PortUnion-Kemper-Evendale.4683</Name>
    <LastEdit Timestamp="2024-06-04T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08EVNDL2" b2="138 KV" b3="929" />
      <ContingencyEquipment Action="L" Type="LN" b1="08EVNDL2" b2="138 KV" b3="08E-08K1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEMPER" b2="138 KV" b3="08K-POR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEMPER" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEMPER" b2="138 KV" b3="BK5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="138 KV" b3="835" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59650</SeqNum>
    <Name>L138.Terminal-Evendale</Name>
    <LastEdit Timestamp="2024-06-04T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08EVNDL2" b2="138 KV" b3="932" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EVNDL2" b2="138 KV" b3="952" />
      <ContingencyEquipment Action="L" Type="LN" b1="08EVNDL2" b2="138 KV" b3="08E-TER3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="138 KV" b3="913" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59660</SeqNum>
    <Name>L138.Foster-TwntyMile-Smpsn-Soclvl-PortUnion.5483</Name>
    <LastEdit Timestamp="2024-11-05T14:59:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DIMMICK" b2="138 KV" b3="08D-POR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DIMMICK" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DIMMICK" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DIMMICK" b2="138 KV" b3="DIM-TP54" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="138 KV" b3="965" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MONTGMRY" b2="138 KV" b3="969" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="138 KV" b3="900" />
      <ContingencyEquipment Action="L" Type="LN" b1="SIMPSON" b2="138 KV" b3="08S-08S4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SIMPSON" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SIMPSON" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SIMPSON" b2="138 KV" b3="BK3" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOCIALVL" b2="138 KV" b3="08S-08T4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOCIALVL" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOCIALVL" b2="138 KV" b3="BK3" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONTGMRY" b2="138 KV" b3="MON-08T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SIMPSON" b2="138 KV" b3="08S-TWE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TWENTY_M" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TWENTY_M" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTER2" b2="138 KV" b3="FOS-TWE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59670</SeqNum>
    <Name>L138.Foster-Park-Bethany-ShakerRun</Name>
    <LastEdit Timestamp="2024-06-04T15:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BETHNY" b2="138 KV" b3="BET-SHK" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHNY" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHNY" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHNY" b2="138 KV" b3="BK3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHNY" b2="138 KV" b3="BK4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="138 KV" b3="964" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHNY" b2="138 KV" b3="08B-PAR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PARKCGE" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PARKCGE" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PARKCGE" b2="138 KV" b3="BK3" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTER2" b2="138 KV" b3="FOS-PAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHKR_RUN" b2="138 KV" b3="824" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHKR_RUN" b2="138 KV" b3="828" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59680</SeqNum>
    <Name>138.Dravosburg.CapA&amp;B</Name>
    <LastEdit Timestamp="2024-06-04T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="DRAVOSBU" b2="138 KV" b3="CAP A" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DRAVOSBU" b2="138 KV" b3="CAP B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="CAPAB CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59690</SeqNum>
    <Name>138/69.Oakley.BK10</Name>
    <LastEdit Timestamp="2024-06-04T10:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="138 KV" b3="804" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="138 KV" b3="805" />
      <ContingencyEquipment Action="X" Type="XF" b1="08OAKLEY" b2="138 KV" b3="BK10_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="08OAKLEY" b2="69 KV" b3="BK10_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="69 KV" b3="CB602" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="69 KV" b3="CB702" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59700</SeqNum>
    <Name>138/69.Kenton.BK4</Name>
    <LastEdit Timestamp="2024-06-04T10:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTON" b2="138 KV" b3="981" />
      <ContingencyEquipment Action="X" Type="XF" b1="KENTON" b2="138 KV" b3="BK4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTON" b2="69 KV" b3="CB664" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59710</SeqNum>
    <Name>DTX138.Ashland.BK7</Name>
    <LastEdit Timestamp="2024-06-12T15:10:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08ASHLD7" b2="138 KV" b3="859" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08ASHLD7" b2="138 KV" b3="860" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08ASHLD7" b2="138 KV" b3="BK7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59720</SeqNum>
    <Name>138/69.Mitchell.BK1 &amp; 138/13.Mitchell.BK3</Name>
    <LastEdit Timestamp="2025-12-09T16:41:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHCGE" b2="138 KV" b3="831" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHCGE" b2="138 KV" b3="833" />
      <ContingencyEquipment Action="X" Type="XF" b1="MITCHCGE" b2="138 KV" b3="BK_1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MITCHCGE" b2="138 KV" b3="BK_3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHCGE" b2="69 KV" b3="CB615" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MITCHCGE" b2="13.2 KV" b3="LD3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59730</SeqNum>
    <Name>138/69.Mitchell.BK4</Name>
    <LastEdit Timestamp="2025-12-17T13:05:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHCGE" b2="138 KV" b3="842" />
      <ContingencyEquipment Action="X" Type="XF" b1="MITCHCGE" b2="138 KV" b3="BK4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHCGE" b2="69 KV" b3="CB611" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59740</SeqNum>
    <Name>138/69.Terminal.BK1</Name>
    <LastEdit Timestamp="2024-06-04T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="138 KV" b3="901" />
      <ContingencyEquipment Action="X" Type="XF" b1="TERMINAL" b2="138 KV" b3="BK1_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="TERMINAL" b2="69 KV" b3="BK1_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="TERMINAL" b2="13.2 KV" b3="BK1_T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="69 KV" b3="CB604" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="69 KV" b3="CB704" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59750</SeqNum>
    <Name>138/69.Terminal.BK2</Name>
    <LastEdit Timestamp="2024-06-06T08:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="138 KV" b3="911" />
      <ContingencyEquipment Action="X" Type="XF" b1="TERMINAL" b2="138 KV" b3="BK-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="69 KV" b3="CB623" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="69 KV" b3="CB723" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59760</SeqNum>
    <Name>345/138.Terminal.BK11</Name>
    <LastEdit Timestamp="2024-06-06T08:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TERMINAL" b2="345 KV" b3="11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="345 KV" b3="1307" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="345 KV" b3="1309" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="138 KV" b3="907" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="138 KV" b3="917" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59770</SeqNum>
    <Name>345/138.Terminal.BK12</Name>
    <LastEdit Timestamp="2024-06-06T08:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TERMINAL" b2="345 KV" b3="12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="345 KV" b3="1305" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="345 KV" b3="1311" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="138 KV" b3="905" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="138 KV" b3="915" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59780</SeqNum>
    <Name>138/69.Beckjord.BK9</Name>
    <LastEdit Timestamp="2025-11-21T12:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="69 KV" b3="632" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="69 KV" b3="638" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="925" />
      <ContingencyEquipment Action="X" Type="XF" b1="BECKJORD" b2="138 KV" b3="BK9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59790</SeqNum>
    <Name>Woodsdale.CT1 &amp; CT2</Name>
    <LastEdit Timestamp="2024-06-10T16:35:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="345 KV" b3="1502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="13.5 KV" b3="311" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="13.5 KV" b3="321" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODSDAL" b2="345 KV" b3="39-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODSDAL" b2="13.5 KV" b3="39-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODSDAL" b2="13.5 KV" b3="39-T" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODSDAL" b2="13.5 KV" b3="CT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODSDAL" b2="13.5 KV" b3="CT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59800</SeqNum>
    <Name>Woodsdale.CT3 &amp; CT4</Name>
    <LastEdit Timestamp="2024-06-10T16:35:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="345 KV" b3="1504" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="13.5 KV" b3="331" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="13.5 KV" b3="341" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODSDAL" b2="345 KV" b3="40-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODSDAL" b2="13.5 KV" b3="40-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODSDAL" b2="13.5 KV" b3="40-T" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODSDAL" b2="13.5 KV" b3="CT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODSDAL" b2="13.5 KV" b3="CT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59810</SeqNum>
    <Name>Woodsdale.CT5 &amp; CT6</Name>
    <LastEdit Timestamp="2024-06-10T16:36:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="345 KV" b3="1508" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="13.5 KV" b3="351" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="13.5 KV" b3="361" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODSDAL" b2="345 KV" b3="41-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODSDAL" b2="13.5 KV" b3="41-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODSDAL" b2="13.5 KV" b3="41-T" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODSDAL" b2="13.5 KV" b3="CT5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODSDAL" b2="13.5 KV" b3="CT6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59820</SeqNum>
    <Name>138/69.Carlisle.BK2</Name>
    <LastEdit Timestamp="2024-06-10T16:30:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08CRLISL" b2="138 KV" b3="952" />
      <ContingencyEquipment Action="X" Type="XF" b1="08CRLISL" b2="138 KV" b3="BK2_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="08CRLISL" b2="69 KV" b3="BK2_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="08CRLISL" b2="13.2 KV" b3="BK2_T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08CRLISL" b2="69 KV" b3="CB622" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08CRLISL" b2="13.2 KV" b3="LD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59830</SeqNum>
    <Name>138/69.PortUnion.BK1</Name>
    <LastEdit Timestamp="2024-06-06T08:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="138 KV" b3="903" />
      <ContingencyEquipment Action="X" Type="XF" b1="PORTUNIO" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="69 KV" b3="CB603" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="69 KV" b3="CB703" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59840</SeqNum>
    <Name>138/69.PortUnion.BK2</Name>
    <LastEdit Timestamp="2024-06-10T16:34:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="138 KV" b3="805" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="138 KV" b3="905" />
      <ContingencyEquipment Action="X" Type="XF" b1="PORTUNIO" b2="138 KV" b3="BK2_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="PORTUNIO" b2="69 KV" b3="BK2_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="PORTUNIO" b2="13.2 KV" b3="BK2_T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="13.2 KV" b3="CB272" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="69 KV" b3="CB605" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="69 KV" b3="CB705" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PORTUNIO" b2="13.2 KV" b3="LD2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PORTUNIO" b2="13.2 KV" b3="LD5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59850</SeqNum>
    <Name>138/69.PortUnion.BK3</Name>
    <LastEdit Timestamp="2024-06-10T16:35:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="138 KV" b3="807" />
      <ContingencyEquipment Action="X" Type="XF" b1="PORTUNIO" b2="138 KV" b3="BK3_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="PORTUNIO" b2="69 KV" b3="BK3_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="PORTUNIO" b2="33 KV" b3="BK3_T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="33 KV" b3="CB464" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="69 KV" b3="CB708" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PORTUNIO" b2="33 KV" b3="LD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59860</SeqNum>
    <Name>345/138.PortUnion.T19</Name>
    <LastEdit Timestamp="2024-06-06T08:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="345 KV" b3="1365" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="345 KV" b3="1371" />
      <ContingencyEquipment Action="X" Type="XF" b1="PORTUNIO" b2="345 KV" b3="19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="138 KV" b3="907" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59870</SeqNum>
    <Name>345/138.PortUnion.T20</Name>
    <LastEdit Timestamp="2024-06-06T08:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="345 KV" b3="1369" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="345 KV" b3="1375" />
      <ContingencyEquipment Action="X" Type="XF" b1="PORTUNIO" b2="345 KV" b3="20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="138 KV" b3="804" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59880</SeqNum>
    <Name>138/69.Evandale.BK1</Name>
    <LastEdit Timestamp="2024-06-10T16:32:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08EVNDL2" b2="138 KV" b3="925" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EVNDL2" b2="138 KV" b3="929" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EVNDL2" b2="138 KV" b3="930" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EVNDL2" b2="138 KV" b3="932" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EVNDL2" b2="138 KV" b3="936" />
      <ContingencyEquipment Action="X" Type="XF" b1="08EVNDL2" b2="138 KV" b3="BK1_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="08EVNDL2" b2="69 KV" b3="BK1_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="08EVNDL2" b2="33 KV" b3="BK1_T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EVNDL2" b2="33 KV" b3="CB568" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EVNDL2" b2="69 KV" b3="CB764" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08EVNDL2" b2="138 KV" b3="GE5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08EVNDL2" b2="138 KV" b3="GE7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59890</SeqNum>
    <Name>138/69.Evandale.BK2</Name>
    <LastEdit Timestamp="2024-06-10T16:33:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08EVNDL2" b2="138 KV" b3="948" />
      <ContingencyEquipment Action="X" Type="XF" b1="08EVNDL2" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EVNDL2" b2="69 KV" b3="CB787" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59900</SeqNum>
    <Name>345/138.Foster.T11</Name>
    <LastEdit Timestamp="2024-06-06T08:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FOSTER2" b2="345 KV" b3="11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="345 KV" b3="1343" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="345 KV" b3="1355" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="138 KV" b3="962" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59910</SeqNum>
    <Name>138/69.Todhunter.BK1</Name>
    <LastEdit Timestamp="2024-06-06T08:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="941" />
      <ContingencyEquipment Action="X" Type="XF" b1="TODDHUNT" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="69 KV" b3="CB645" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59920</SeqNum>
    <Name>138/69.Todhunter.BK2</Name>
    <LastEdit Timestamp="2024-06-06T08:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="945" />
      <ContingencyEquipment Action="X" Type="XF" b1="TODDHUNT" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="69 KV" b3="CB653" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59930</SeqNum>
    <Name>345/138.Todhunter.T15</Name>
    <LastEdit Timestamp="2024-06-06T08:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="345 KV" b3="1383" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="345 KV" b3="1385" />
      <ContingencyEquipment Action="X" Type="XF" b1="TODDHUNT" b2="345 KV" b3="15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="917" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="919" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59940</SeqNum>
    <Name>345/138.Todhunter.T16</Name>
    <LastEdit Timestamp="2024-06-06T08:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="345 KV" b3="1387" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="345 KV" b3="1395" />
      <ContingencyEquipment Action="X" Type="XF" b1="TODDHUNT" b2="345 KV" b3="16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="913" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="915" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59950</SeqNum>
    <Name>345/138.Todhunter.T17</Name>
    <LastEdit Timestamp="2024-06-06T08:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="345 KV" b3="1381" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="345 KV" b3="1389" />
      <ContingencyEquipment Action="X" Type="XF" b1="TODDHUNT" b2="345 KV" b3="17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="923" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="925" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59960</SeqNum>
    <Name>138/69/33.Fairfield.BK2</Name>
    <LastEdit Timestamp="2025-01-06T15:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08FRFLD1" b2="138 KV" b3="881" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08FRFLD1" b2="138 KV" b3="894" />
      <ContingencyEquipment Action="X" Type="XF" b1="08FRFLD1" b2="138 KV" b3="BK2_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="08FRFLD1" b2="69 KV" b3="BK2_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="08FRFLD1" b2="33 KV" b3="BK2_T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08FRFLD1" b2="69 KV" b3="CB633" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08FRFLD1" b2="33 KV" b3="LD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59970</SeqNum>
    <Name>138/69.Brown.BK1</Name>
    <LastEdit Timestamp="2026-05-11T09:05:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="08BROWN" b2="69 KV" b3="08B-TP5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08BROWN" b2="69 KV" b3="41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08BROWN" b2="138 KV" b3="823" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08BROWN" b2="138 KV" b3="834" />
      <ContingencyEquipment Action="X" Type="XF" b1="08BROWN" b2="138 KV" b3="BK1_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="08BROWN" b2="69 KV" b3="BK1_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="08BROWN" b2="33 KV" b3="BK1_T" />
      <ContingencyEquipment Action="U" Type="GEN" b1="08BROWN" b2="33 KV" b3="BROWNLF" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="08BROWN" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08BROWN" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08BROWN" b2="33 KV" b3="LD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59980</SeqNum>
    <Name>138/69.WILDER.BK1</Name>
    <LastEdit Timestamp="2025-04-23T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08WLDER1" b2="138 KV" b3="829" />
      <ContingencyEquipment Action="X" Type="XF" b1="08WLDER1" b2="69 KV" b3="BK-1_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="08WLDER1" b2="13.2 KV" b3="BK-1_T" />
      <ContingencyEquipment Action="X" Type="XF" b1="08WLDER1" b2="138 KV" b3="BK1_P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08WLDER1" b2="69 KV" b3="CB646" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08WLDER1" b2="13.2 KV" b3="LD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>59990</SeqNum>
    <Name>138/69.WILDER.BK2</Name>
    <LastEdit Timestamp="2025-04-23T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08WLDER1" b2="138 KV" b3="831" />
      <ContingencyEquipment Action="X" Type="XF" b1="08WLDER1" b2="69 KV" b3="BK-2_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="08WLDER1" b2="13.2 KV" b3="BK-2_T" />
      <ContingencyEquipment Action="X" Type="XF" b1="08WLDER1" b2="138 KV" b3="BK2_P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08WLDER1" b2="69 KV" b3="CB743" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08WLDER1" b2="13.2 KV" b3="LD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60000</SeqNum>
    <Name>138/69.MiamiFort.T17</Name>
    <LastEdit Timestamp="2025-09-02T10:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MIAMIFOR" b2="138 KV" b3="17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="69 KV" b3="711" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="826" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="830" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60010</SeqNum>
    <Name>138/69.Buffington.BK1</Name>
    <LastEdit Timestamp="2025-03-14T09:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="138 KV" b3="931" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUFFINGT" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="69 KV" b3="CB681" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60020</SeqNum>
    <Name>138/69.Buffington.BK2</Name>
    <LastEdit Timestamp="2024-06-06T08:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="138 KV" b3="941" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUFFINGT" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="69 KV" b3="CB677" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60030</SeqNum>
    <Name>345/138.Buffington.45</Name>
    <LastEdit Timestamp="2024-06-06T08:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="345 KV" b3="1525" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="345 KV" b3="1531" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUFFINGT" b2="345 KV" b3="45" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="138 KV" b3="934" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="138 KV" b3="944" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60040</SeqNum>
    <Name>345/138.Buffington.46</Name>
    <LastEdit Timestamp="2024-06-06T08:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="345 KV" b3="1523" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="345 KV" b3="1529" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUFFINGT" b2="345 KV" b3="46" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="138 KV" b3="937" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="138 KV" b3="947" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60050</SeqNum>
    <Name>138/69.Ebenezer.BK5</Name>
    <LastEdit Timestamp="2025-01-31T15:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="08EBNZR5" b2="138 KV" b3="BK5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EBNZR5" b2="69 KV" b3="CB669" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EBNZR5" b2="138 KV" b3="CB947" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60060</SeqNum>
    <Name>DTX138.Ebenezer.BK6</Name>
    <LastEdit Timestamp="2025-03-18T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08EBNZR5" b2="138 KV" b3="950" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EBNZR5" b2="138 KV" b3="951" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08EBNZR5" b2="138 KV" b3="BK6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60070</SeqNum>
    <Name>138/69 Summerside.BK2</Name>
    <LastEdit Timestamp="2024-06-10T16:30:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="08SMRSD1" b2="138 KV" b3="2_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="08SMRSD1" b2="69 KV" b3="2_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="08SMRSD1" b2="33 KV" b3="2_T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08SMRSD1" b2="138 KV" b3="846" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08SMRSD1" b2="138 KV" b3="850" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08SMRSD1" b2="33 KV" b3="LD_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08SMRSD1" b2="69 KV" b3="SW661" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60080</SeqNum>
    <Name>345/138.RedBank.T28 (Sctnlz ACS off/failed)</Name>
    <LastEdit Timestamp="2024-06-06T08:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="REDBANK" b2="345 KV" b3="28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBANK" b2="138 KV" b3="922" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="REDBANK" b2="345 KV" b3="SW1488" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60100</SeqNum>
    <Name>138/69.Warren.BK1</Name>
    <LastEdit Timestamp="2024-06-06T08:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08WARREN" b2="138 KV" b3="871" />
      <ContingencyEquipment Action="X" Type="XF" b1="08WARREN" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08WARREN" b2="69 KV" b3="CB651" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60110</SeqNum>
    <Name>EastBend.U2</Name>
    <LastEdit Timestamp="2024-06-05T11:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEND" b2="345 KV" b3="1585" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEND" b2="345 KV" b3="1587" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EBEND" b2="20 KV" b3="AUX2A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EBEND" b2="20 KV" b3="AUX2B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EBEND" b2="20 KV" b3="AUX2C" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EBEND" b2="20 KV" b3="EB2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EBEND" b2="20 KV" b3="EB2_D" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EBEND" b2="20 KV" b3="G2" />
      <ContingencyEquipment Action="X" Type="XF" b1="EBEND" b2="345 KV" b3="GSU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEND" b2="20 KV" b3="UN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEND" b2="20 KV" b3="UND_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60120</SeqNum>
    <Name>138.WoodvilleDUQ.Cap1</Name>
    <LastEdit Timestamp="2025-10-15T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="WOODVILL" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVILL" b2="138 KV" b3="CAP1CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60140</SeqNum>
    <Name>230/69.Lauschtown.T1</Name>
    <LastEdit Timestamp="2024-06-05T11:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LAUSCHTO" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="230 KV" b3="TRAN1_H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="69 KV" b3="TRAN1_L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60150</SeqNum>
    <Name>230/69.Lauschtown.T2</Name>
    <LastEdit Timestamp="2024-06-05T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LAUSCHTO" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="230 KV" b3="TRAN2_H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="69 KV" b3="TRAN2_L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60170</SeqNum>
    <Name>MiamiFort.U7</Name>
    <LastEdit Timestamp="2024-11-21T09:53:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1403" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1405" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MIAMIFOR" b2="22 KV" b3="G7" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIAMIFOR" b2="345 KV" b3="GSU7" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIAMIFOR" b2="22 KV" b3="LD7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60180</SeqNum>
    <Name>MiamiFort.U8</Name>
    <LastEdit Timestamp="2024-06-10T16:20:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1413" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1417" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MIAMIFOR" b2="22 KV" b3="G8" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIAMIFOR" b2="345 KV" b3="GSU8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIAMIFOR" b2="22 KV" b3="LD8" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MIAMIFOR" b2="22 KV" b3="MI8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60190</SeqNum>
    <Name>MiamiFort.CT3</Name>
    <LastEdit Timestamp="2024-06-05T12:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="13.2 KV" b3="433" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MIAMIFOR" b2="13.2 KV" b3="CT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60200</SeqNum>
    <Name>MiamiFort.CT4</Name>
    <LastEdit Timestamp="2024-06-05T12:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="13.2 KV" b3="444" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MIAMIFOR" b2="13.2 KV" b3="CT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60210</SeqNum>
    <Name>MiamiFort.CT5</Name>
    <LastEdit Timestamp="2024-06-05T12:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="13.2 KV" b3="455" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MIAMIFOR" b2="13.2 KV" b3="CT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60220</SeqNum>
    <Name>MiamiFort.CT6</Name>
    <LastEdit Timestamp="2024-06-05T12:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="13.2 KV" b3="466" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MIAMIFOR" b2="13.2 KV" b3="CT6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60260</SeqNum>
    <Name>L345.Kincaid-Austin.2106</Name>
    <LastEdit Timestamp="2024-06-05T11:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AUSTIN" b2="345 KV" b3="AUS-21K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="21 KINCA" b2="345 KV" b3="BT5-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="21 KINCA" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUSTIN" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUSTIN" b2="345 KV" b3="V13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60270</SeqNum>
    <Name>L345.Austin-Mogl (AMRN/MISO)</Name>
    <LastEdit Timestamp="2026-05-05T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AUSTIN" b2="345 KV" b3="V31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUSTIN" b2="345 KV" b3="V33" />
      <ContingencyEquipment Action="L" Type="LN" b1="AUSTIN" b2="345 KV" b3="AUS-MOGL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOGL" b2="345 KV" b3="V5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOGL" b2="345 KV" b3="V7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60290</SeqNum>
    <Name>DicksCreek.CT1</Name>
    <LastEdit Timestamp="2024-06-10T16:21:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="D_C_GEN" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="D_C_GEN" b2="138 KV" b3="961" />
      <ContingencyEquipment Action="U" Type="GEN" b1="D_C_GEN" b2="13 KV" b3="CT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60300</SeqNum>
    <Name>DicksCreek.CT3</Name>
    <LastEdit Timestamp="2024-06-10T16:21:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="D_C_GEN" b2="13 KV" b3="233" />
      <ContingencyEquipment Action="U" Type="GEN" b1="D_C_GEN" b2="13 KV" b3="CT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60310</SeqNum>
    <Name>DicksCreek.CT4</Name>
    <LastEdit Timestamp="2024-06-10T16:21:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="D_C_GEN" b2="13 KV" b3="344" />
      <ContingencyEquipment Action="U" Type="GEN" b1="D_C_GEN" b2="13 KV" b3="CT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60320</SeqNum>
    <Name>DicksCreek.CT5</Name>
    <LastEdit Timestamp="2024-06-10T16:22:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="D_C_GEN" b2="13 KV" b3="355" />
      <ContingencyEquipment Action="U" Type="GEN" b1="D_C_GEN" b2="13 KV" b3="CT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60330</SeqNum>
    <Name>Woodsdale.CT1</Name>
    <LastEdit Timestamp="2024-06-10T16:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="13.5 KV" b3="311" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODSDAL" b2="13.5 KV" b3="CT1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODSDAL" b2="13.5 KV" b3="TB1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60340</SeqNum>
    <Name>Woodsdale.CT2</Name>
    <LastEdit Timestamp="2024-06-10T16:28:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="13.5 KV" b3="321" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODSDAL" b2="13.5 KV" b3="CT2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODSDAL" b2="13.5 KV" b3="TB2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60350</SeqNum>
    <Name>Woodsdale.CT3</Name>
    <LastEdit Timestamp="2024-06-10T16:28:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="13.5 KV" b3="331" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODSDAL" b2="13.5 KV" b3="CT3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODSDAL" b2="13.5 KV" b3="TB3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60360</SeqNum>
    <Name>Woodsdale.CT4</Name>
    <LastEdit Timestamp="2024-06-10T16:28:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="13.5 KV" b3="341" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODSDAL" b2="13.5 KV" b3="CT4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODSDAL" b2="13.5 KV" b3="TB4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60370</SeqNum>
    <Name>Woodsdale.CT5</Name>
    <LastEdit Timestamp="2024-06-10T16:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="13.5 KV" b3="351" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODSDAL" b2="13.5 KV" b3="CT5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODSDAL" b2="13.5 KV" b3="TB5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60380</SeqNum>
    <Name>Woodsdale.CT6</Name>
    <LastEdit Timestamp="2024-06-10T16:29:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSDAL" b2="13.5 KV" b3="361" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODSDAL" b2="13.5 KV" b3="CT6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODSDAL" b2="13.5 KV" b3="TB6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60390</SeqNum>
    <Name>L138.PortUnion-Becket-Todhunter.3888</Name>
    <LastEdit Timestamp="2024-06-10T16:26:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BECKET" b2="138 KV" b3="BEC-TOD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BECKET" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PORTUNIO" b2="138 KV" b3="POR-BEC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="138 KV" b3="812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="935" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="937" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60400</SeqNum>
    <Name>L138.Bolingbrook-Normantown.52517</Name>
    <LastEdit Timestamp="2026-05-08T14:16:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="525 NORM" b2="138 KV" b3="L52517" />
      <ContingencyEquipment Action="OP" Type="CB" b1="52517" b2="138 KV" b3="517-0319" />
      <ContingencyEquipment Action="L" Type="LN" b1="52517" b2="138 KV" b3="517-BOLN" />
      <ContingencyEquipment Action="L" Type="LN" b1="52517" b2="138 KV" b3="52517 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="52517" b2="138 KV" b3="52517 2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="561 BOLN" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="561 BOLN" b2="138 KV" b3="L52517CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60410</SeqNum>
    <Name>L138.Foster-Enyart-Montgomery-Remington</Name>
    <LastEdit Timestamp="2025-05-23T14:52:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ENYART" b2="138 KV" b3="ENY-FOS" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENYART" b2="138 KV" b3="ENY-MON" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ENYART" b2="138 KV" b3="TB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="138 KV" b3="967" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MONTGMRY" b2="138 KV" b3="969" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONTGMRY" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONTGMRY" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONTGMRY" b2="138 KV" b3="BK3" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONTGMRY" b2="138 KV" b3="MON-08R1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGT" b2="138 KV" b3="825" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGT" b2="138 KV" b3="829" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60420</SeqNum>
    <Name>L138.Foster-Obannonville-Cedarville</Name>
    <LastEdit Timestamp="2024-06-10T16:25:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARVIL" b2="138 KV" b3="969" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="138 KV" b3="961" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OBANNONV" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTER2" b2="138 KV" b3="FOS-OBA" />
      <ContingencyEquipment Action="L" Type="LN" b1="OBANNONV" b2="138 KV" b3="OBA-CED" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60430</SeqNum>
    <Name>L138.Todhunter-Nickel-Warren</Name>
    <LastEdit Timestamp="2025-11-10T14:10:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08WARREN" b2="138 KV" b3="872" />
      <ContingencyEquipment Action="L" Type="LN" b1="08WARREN" b2="138 KV" b3="08W-NIC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NICKEL" b2="13.2 KV" b3="BK1_LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NICKEL" b2="13.2 KV" b3="BK2_LD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NICKEL" b2="13.2 KV" b3="CI1ZOOSP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NICKEL" b2="13.2 KV" b3="CI2ZOOSP" />
      <ContingencyEquipment Action="L" Type="LN" b1="NICKEL" b2="138 KV" b3="NIC-TOD" />
      <ContingencyEquipment Action="X" Type="XF" b1="NICKEL" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NICKEL" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="911" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="913" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60440</SeqNum>
    <Name>L138.ARMCO-DicksCreekGen</Name>
    <LastEdit Timestamp="2025-07-10T10:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMCO_1C" b2="138 KV" b3="622" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARMCO_1C" b2="138 KV" b3="ARM-DCGE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="D_C_GEN" b2="138 KV" b3="957" />
      <ContingencyEquipment Action="OP" Type="CB" b1="D_C_GEN" b2="138 KV" b3="960" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60450</SeqNum>
    <Name>L138.Toddhunter-ARMCO</Name>
    <LastEdit Timestamp="2025-12-17T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMCO_1C" b2="138 KV" b3="621" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARMCO_1C" b2="138 KV" b3="ARM-TODD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="931" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="933" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60470</SeqNum>
    <Name>L138.Fairfield-CityOfHamilton</Name>
    <LastEdit Timestamp="2024-11-15T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08FRFLD1" b2="138 KV" b3="892" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08FRFLD1" b2="138 KV" b3="894" />
      <ContingencyEquipment Action="L" Type="LN" b1="08FRFLD1" b2="138 KV" b3="08F-08H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08HAMLTN" b2="138 KV" b3="934" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08HAMLTN" b2="138 KV" b3="936" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60480</SeqNum>
    <Name>L138.Morgan-Fairfield</Name>
    <LastEdit Timestamp="2024-12-30T14:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MRGAN" b2="138 KV" b3="08F-MRG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08FRFLD1" b2="138 KV" b3="888" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08FRFLD1" b2="138 KV" b3="890" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MRGAN" b2="138 KV" b3="950" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MRGAN" b2="138 KV" b3="958" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60490</SeqNum>
    <Name>L138.Brown-Eastwood</Name>
    <LastEdit Timestamp="2024-06-05T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="08BROWN" b2="138 KV" b3="08B-08E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08BROWN" b2="138 KV" b3="823" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08BROWN" b2="138 KV" b3="825" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTWOOD" b2="138 KV" b3="861" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60500</SeqNum>
    <Name>L138.Wilder-York-Belvue-Dayton-Lafarge-SilverGrove</Name>
    <LastEdit Timestamp="2024-06-05T12:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08WLDER1" b2="138 KV" b3="822" />
      <ContingencyEquipment Action="L" Type="LN" b1="YORK77" b2="138 KV" b3="YOR-08W" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELVUE" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELVUE" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELVUE" b2="138 KV" b3="CB927" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELVUE" b2="138 KV" b3="CB934" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAYTON76" b2="138 KV" b3="DAY-BEL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAYTON76" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAFARGE" b2="138 KV" b3="LAF-DAY" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAFARGE" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAFARGE" b2="138 KV" b3="SIL-LAF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERGR" b2="138 KV" b3="818" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELVUE" b2="138 KV" b3="BEL-YOR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="YORK77" b2="138 KV" b3="BK1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60510</SeqNum>
    <Name>L138.Wilder-Augustine-WestEnd.5985</Name>
    <LastEdit Timestamp="2026-06-01T10:09:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08WLDER1" b2="138 KV" b3="837" />
      <ContingencyEquipment Action="L" Type="LN" b1="AUGTINE" b2="138 KV" b3="08A-08W2" />
      <ContingencyEquipment Action="L" Type="LN" b1="AUGTINE" b2="138 KV" b3="08A-WEN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AUGTINE" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AUGTINE" b2="138 KV" b3="BK3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AUGTINE" b2="138 KV" b3="BK5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="951" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="953" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60520</SeqNum>
    <Name>L138.Wilder-KentuckyUniversity-SilverGrove</Name>
    <LastEdit Timestamp="2024-06-10T16:27:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08WLDER1" b2="138 KV" b3="832" />
      <ContingencyEquipment Action="L" Type="LN" b1="KY_UNIV" b2="138 KV" b3="08K-08W2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KY_UNIV" b2="138 KV" b3="08K-SIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KY_UNIV" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KY_UNIV" b2="138 KV" b3="BK4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERGR" b2="138 KV" b3="812" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60530</SeqNum>
    <Name>L138.Beckjord-Cold Spring-Wilder</Name>
    <LastEdit Timestamp="2024-06-05T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="08COLDSP" b2="138 KV" b3="08C-08W2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BECKJORD" b2="138 KV" b3="BEC-08C1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08COLDSP" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08WLDER1" b2="138 KV" b3="828" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="924" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60540</SeqNum>
    <Name>L138.LoughsLane-Leadsville</Name>
    <LastEdit Timestamp="2025-06-25T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEADSVIL" b2="138 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEADSVIL" b2="138 KV" b3="CB3" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEADSVIL" b2="138 KV" b3="LEA-LOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUGHSLA" b2="138 KV" b3="BELINGTO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60550</SeqNum>
    <Name>L138.Webster-Hands-Kenton-SilverGrove</Name>
    <LastEdit Timestamp="2024-11-15T15:26:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HANDS" b2="138 KV" b3="08H-SIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HANDS" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HANDS" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANDS" b2="138 KV" b3="HAN-KEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTON" b2="138 KV" b3="981" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERGR" b2="138 KV" b3="814" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEBSTER2" b2="138 KV" b3="962" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEBSTER2" b2="138 KV" b3="968" />
      <ContingencyEquipment Action="L" Type="LN" b1="WEBSTER2" b2="138 KV" b3="HAN-WEB1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60560</SeqNum>
    <Name>Leadsville.LaurelWF</Name>
    <LastEdit Timestamp="2026-03-25T14:50:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEADSVIL" b2="138 KV" b3="CB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEADSVIL" b2="138 KV" b3="CB3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEADSVIL" b2="138 KV" b3="CB4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEADSVIL" b2="34.5 KV" b3="LAURLWF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LEADSVIL" b2="34.5 KV" b3="LAURMTWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEADSVIL" b2="138 KV" b3="TRAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60580</SeqNum>
    <Name>L138.Buffington-MtZion</Name>
    <LastEdit Timestamp="2025-02-07T12:41:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="138 KV" b3="933" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MT_ZION1" b2="138 KV" b3="874" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MT_ZION1" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MT_ZION1" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUFFINGT" b2="138 KV" b3="BUF-MTZ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60590</SeqNum>
    <Name>L138.MiamiFort-Ebenezer</Name>
    <LastEdit Timestamp="2025-01-31T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08EBNZR5" b2="138 KV" b3="949" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EBNZR5" b2="138 KV" b3="959" />
      <ContingencyEquipment Action="L" Type="LN" b1="08EBNZR5" b2="138 KV" b3="08E-MIA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="810" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60600</SeqNum>
    <Name>L138.Beckjord-Aicholtz-Summerside</Name>
    <LastEdit Timestamp="2026-03-26T10:53:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08SMRSD1" b2="138 KV" b3="845" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08SMRSD1" b2="138 KV" b3="846" />
      <ContingencyEquipment Action="L" Type="LN" b1="AICHOLTZ" b2="138 KV" b3="AIC-08SM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AICHOLTZ" b2="138 KV" b3="LD3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="813" />
      <ContingencyEquipment Action="L" Type="LN" b1="AICHOLTZ" b2="138 KV" b3="AIC-BECK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60610</SeqNum>
    <Name>L138.Hebron-Constance-Crescent.7086</Name>
    <LastEdit Timestamp="2024-06-10T16:26:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08CNSTNC" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08CNSTNC" b2="138 KV" b3="CB974" />
      <ContingencyEquipment Action="L" Type="LN" b1="08CNSTNC" b2="138 KV" b3="08C-08C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESCNT" b2="138 KV" b3="838" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESCNT" b2="138 KV" b3="860" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRON1" b2="138 KV" b3="853" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRON1" b2="138 KV" b3="857" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HEBRON1" b2="138 KV" b3="890" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEBRON1" b2="138 KV" b3="HEB-08C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HEBRON1" b2="138 KV" b3="TB2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60620</SeqNum>
    <Name>L138.MiamiFor-NBend-TP7284-Kleeman-Glenview</Name>
    <LastEdit Timestamp="2026-01-23T09:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLNVIEW" b2="138 KV" b3="847" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLNVIEW" b2="138 KV" b3="08G-08K2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KLEEMAN" b2="138 KV" b3="08K-08M1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KLEEMAN" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KLEEMAN" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KLEEMAN" b2="138 KV" b3="BK3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="909" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDWAY2" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NBEND" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIAMIFOR" b2="138 KV" b3="MIA-NBEN" />
      <ContingencyEquipment Action="L" Type="LN" b1="TP7284" b2="138 KV" b3="MID-TP72" />
      <ContingencyEquipment Action="L" Type="LN" b1="NBEND" b2="138 KV" b3="NBE-TP72" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60630</SeqNum>
    <Name>L138.Terminal-Golf-RedBank-DeerPk-Cooper-Cornell</Name>
    <LastEdit Timestamp="2024-11-15T11:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08COOPER" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="08COOPER" b2="138 KV" b3="08C-08T4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORNELL" b2="138 KV" b3="08C-08T5" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEER_PRK" b2="138 KV" b3="08D-08T7" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CORNELL" b2="138 KV" b3="982" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DEER_PRK" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DEER_PRK" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DEER_PRK" b2="138 KV" b3="BK3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DEER_PRK" b2="138 KV" b3="BK5" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOLF_MNR" b2="138 KV" b3="08G-08T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOLF_MNR" b2="138 KV" b3="08G-TER2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOLF_MNR" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBANK" b2="138 KV" b3="915" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="138 KV" b3="924" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEER_PRK" b2="138 KV" b3="08D-08T6" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDBANK" b2="138 KV" b3="RED-08T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60640</SeqNum>
    <Name>L138.Ashland-Oakley-RedBank</Name>
    <LastEdit Timestamp="2024-12-12T14:02:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08ASHLD7" b2="138 KV" b3="861" />
      <ContingencyEquipment Action="L" Type="LN" b1="08ASHLD7" b2="138 KV" b3="ASH-OAK1" />
      <ContingencyEquipment Action="S" Type="SD" b1="08OAKLEY" b2="138 KV" b3="REACTOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBANK" b2="138 KV" b3="923" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDBANK" b2="138 KV" b3="RED-OAK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60650</SeqNum>
    <Name>L138.RedBank-Tobasco</Name>
    <LastEdit Timestamp="2024-06-10T16:27:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08TBSCO1" b2="138 KV" b3="853" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08TBSCO1" b2="138 KV" b3="854" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBANK" b2="138 KV" b3="921" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDBANK" b2="138 KV" b3="RED-08T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60660</SeqNum>
    <Name>L138.Charles-Rochelle</Name>
    <LastEdit Timestamp="2024-06-10T16:22:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLES" b2="138 KV" b3="919" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLES" b2="138 KV" b3="921" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLES" b2="138 KV" b3="08C-08R2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCHELLE" b2="138 KV" b3="916" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCHELLE" b2="138 KV" b3="920" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60670</SeqNum>
    <Name>L138.Rochelle-Terminal</Name>
    <LastEdit Timestamp="2024-06-05T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ROCHELLE" b2="138 KV" b3="08R-TER1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCHELLE" b2="138 KV" b3="930" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCHELLE" b2="138 KV" b3="934" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="138 KV" b3="919" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60690</SeqNum>
    <Name>L138.Beckjord-Feldman-Remington</Name>
    <LastEdit Timestamp="2024-12-05T15:07:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="914" />
      <ContingencyEquipment Action="L" Type="LN" b1="BECKJORD" b2="138 KV" b3="BEC-08F1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FELDMAN" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FELDMAN" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FELDMAN" b2="138 KV" b3="BK3" />
      <ContingencyEquipment Action="L" Type="LN" b1="REMINGT" b2="138 KV" b3="08R1-FEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGT" b2="138 KV" b3="834" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGT" b2="138 KV" b3="836" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60700</SeqNum>
    <Name>L138.Willey-MiamiFort.9784</Name>
    <LastEdit Timestamp="2024-06-05T12:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="808" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLEY" b2="138 KV" b3="843" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLEY" b2="138 KV" b3="943" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIAMIFOR" b2="138 KV" b3="MIA-08W1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60710</SeqNum>
    <Name>L138.Terminal-Finneytn-Mt.Healthy-Maple-Willey</Name>
    <LastEdit Timestamp="2025-11-25T16:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FINNEYTN" b2="138 KV" b3="08F-08M2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FINNEYTN" b2="138 KV" b3="08F-TER1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FINNEYTN" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FINNEYTN" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FINNEYTN" b2="138 KV" b3="BK4" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAPLKNOL" b2="138 KV" b3="08M-08W1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAPLKNOL" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAPLKNOL" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAPLKNOL" b2="138 KV" b3="08M-08M1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MT_HELTY" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MT_HELTY" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="138 KV" b3="906" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLEY" b2="138 KV" b3="942" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLEY" b2="138 KV" b3="943" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLEY" b2="138 KV" b3="947" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILLEY" b2="138 KV" b3="BK3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60730</SeqNum>
    <Name>L345.Foster-Hillcrest</Name>
    <LastEdit Timestamp="2024-06-05T12:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="345 KV" b3="1343" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="345 KV" b3="1349" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTER2" b2="345 KV" b3="FOS-HIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILCRST2" b2="345 KV" b3="1425" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILCRST2" b2="345 KV" b3="1427" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60740</SeqNum>
    <Name>L138.Pierce-Beckjord.5 + 345/138.Pierce.18</Name>
    <LastEdit Timestamp="2025-10-14T18:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="815" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="915" />
      <ContingencyEquipment Action="X" Type="XF" b1="PIERC_DK" b2="345 KV" b3="BK18" />
      <ContingencyEquipment Action="L" Type="LN" b1="BECKJORD" b2="138 KV" b3="PIE-BEC5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERC_DK" b2="345 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERC_DK" b2="345 KV" b3="U" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60750</SeqNum>
    <Name>L138.Eastwood-Hillcrest (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="EASTWOOD" b2="138 KV" b3="857" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILCRST2" b2="138 KV" b3="805" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILCRST2" b2="138 KV" b3="817" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCP_EAST" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTWOOD" b2="138 KV" b3="EAS-SCP" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCP_EAST" b2="138 KV" b3="SCP-HIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60760</SeqNum>
    <Name>L138.Blackwell-BlackwellTP + 138/69.Blackwell.BK1</Name>
    <LastEdit Timestamp="2024-06-10T16:20:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BLACKWEL" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKWEL" b2="138 KV" b3="BLK-BLK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKWEL" b2="69 KV" b3="CB723" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKWEL" b2="69 KV" b3="CB728" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLKWLLG" b2="138 KV" b3="CB_708" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLKWLLG" b2="138 KV" b3="CB_718" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60770</SeqNum>
    <Name>345/138.Hillcrest.TR21</Name>
    <LastEdit Timestamp="2025-05-28T12:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILCRST2" b2="345 KV" b3="1423" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILCRST2" b2="345 KV" b3="1425" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILCRST2" b2="138 KV" b3="817" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILCRST2" b2="138 KV" b3="819" />
      <ContingencyEquipment Action="X" Type="XF" b1="HILCRST2" b2="345 KV" b3="TR21" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60790</SeqNum>
    <Name>L138.Shaker-Rockies</Name>
    <LastEdit Timestamp="2025-01-29T15:21:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROCKIES" b2="138 KV" b3="879" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKIES" b2="138 KV" b3="888" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKIES" b2="138 KV" b3="894" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHKR_RUN" b2="138 KV" b3="822" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHKR_RUN" b2="138 KV" b3="828" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHKR_RUN" b2="138 KV" b3="SHK-ROC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60800</SeqNum>
    <Name>L138.Keith-Mayfield-Northfield.Q1</Name>
    <LastEdit Timestamp="2025-03-31T18:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02KHTP" b2="138 KV" b3="02K-KEI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02KHTP" b2="138 KV" b3="02K-KEL1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KEITH" b2="138 KV" b3="SW313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEITH" b2="138 KV" b3="SWR122" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KELLY" b2="138 KV" b3="SW313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELLY" b2="138 KV" b3="SWR132" />
      <ContingencyEquipment Action="L" Type="LN" b1="02KHTP" b2="138 KV" b3="02K-KEN1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KENDALL" b2="138 KV" b3="SW313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENDALL" b2="138 KV" b3="SWR131" />
      <ContingencyEquipment Action="L" Type="LN" b1="LESTER" b2="138 KV" b3="LES-KEN1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LESTER" b2="138 KV" b3="SW313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LESTER" b2="138 KV" b3="SWR131" />
      <ContingencyEquipment Action="L" Type="LN" b1="MF_NF_T" b2="138 KV" b3="04K-04M1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MF_NF_T" b2="138 KV" b3="04K-04N1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LESTER" b2="138 KV" b3="LES-04K1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHFLD" b2="138 KV" b3="B16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60810</SeqNum>
    <Name>L138.Keith-Mayfield-Northfield.Q3</Name>
    <LastEdit Timestamp="2025-04-01T15:50:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02KHTP" b2="138 KV" b3="02K-KEL2" />
      <ContingencyEquipment Action="L" Type="LN" b1="02KHTP" b2="138 KV" b3="02K-KEN2" />
      <ContingencyEquipment Action="L" Type="LN" b1="02KHTP" b2="138 KV" b3="02K-KEI2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KEITH" b2="138 KV" b3="SW313" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEITH" b2="138 KV" b3="SW374" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEITH" b2="138 KV" b3="SWR322" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KELLY" b2="138 KV" b3="SW313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELLY" b2="138 KV" b3="SWR332" />
      <ContingencyEquipment Action="L" Type="LN" b1="LESTER" b2="138 KV" b3="LES-KEN2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KENDALL" b2="138 KV" b3="SW313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENDALL" b2="138 KV" b3="SWR331" />
      <ContingencyEquipment Action="L" Type="LN" b1="LESTER" b2="138 KV" b3="LES-04K2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LESTER" b2="138 KV" b3="SW313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LESTER" b2="138 KV" b3="SWR331" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B23" />
      <ContingencyEquipment Action="L" Type="LN" b1="MF_NF_T" b2="138 KV" b3="04K-04M2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MF_NF_T" b2="138 KV" b3="04K-04N2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHFLD" b2="138 KV" b3="Q3_MF_X" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60820</SeqNum>
    <Name>L138.Ashtabula-AshtaChemicals.Q31</Name>
    <LastEdit Timestamp="2025-08-01T13:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="138 KV" b3="B189" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASHTABUL" b2="138 KV" b3="ASH-ASH1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ASH_C" b2="138 KV" b3="Q31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASH_C" b2="138 KV" b3="RQ6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ASH_C" b2="138 KV" b3="TR6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60850</SeqNum>
    <Name>L138.Crossland-Duferco</Name>
    <LastEdit Timestamp="2024-12-24T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSFE" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSFE" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSFE" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSFE" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUFERCO" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROSSFE" b2="138 KV" b3="DUF-CRO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60950</SeqNum>
    <Name>L500.Carson-Suffolk.544</Name>
    <LastEdit Timestamp="2024-06-05T12:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="500 KV" b3="511T544" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARSON4" b2="500 KV" b3="544" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="500 KV" b3="54472" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="500 KV" b3="H7T544" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="500 KV" b3="H8T544" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60960</SeqNum>
    <Name>L230.Chickahominy-Lanexa.2129</Name>
    <LastEdit Timestamp="2025-11-18T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="212922" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICKHOM" b2="230 KV" b3="2129A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="287T2129" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="230 KV" b3="21292208" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="230 KV" b3="212932" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60970</SeqNum>
    <Name>L345.MaddoxCreek-RPMone</Name>
    <LastEdit Timestamp="2024-06-05T12:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MADDOXCR" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADDOXCR" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MADDOXCR" b2="345 KV" b3="MAD-RPM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RPMONE" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RPMONE" b2="345 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>60980</SeqNum>
    <Name>L345.EastLima-MaddoxCreek</Name>
    <LastEdit Timestamp="2024-06-05T12:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MADDOXCR" b2="345 KV" b3="ELI-MAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="345 KV" b3="M2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADDOXCR" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADDOXCR" b2="345 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61000</SeqNum>
    <Name>L230.Deptford-Thorofare-Mickleton.W-2275</Name>
    <LastEdit Timestamp="2024-11-21T09:12:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DEPTFORD" b2="230 KV" b3="DEP-THO" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="DEPTFORD" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEPTFORD" b2="230 KV" b3="SECT1-2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="DEPTFORD" b2="230 KV" b3="TRAN3-4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DEPTFORD" b2="230 KV" b3="TRANT-1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DEPTFORD" b2="230 KV" b3="TRANT-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="U" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="THOROFAR" b2="230 KV" b3="DUMD1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="THOROFAR" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="MICKLETO" b2="230 KV" b3="MIC-THOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOROFAR" b2="230 KV" b3="TRANT-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61010</SeqNum>
    <Name>North Longview.U1</Name>
    <LastEdit Timestamp="2024-06-05T13:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="NLONGVW" b2="26 KV" b3="GEN  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLONGVW" b2="500 KV" b3="NLVL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLONGVW" b2="500 KV" b3="NLVL3" />
      <ContingencyEquipment Action="X" Type="XF" b1="NLONGVW" b2="500 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLONGVW" b2="500 KV" b3="TX1HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLONGVW" b2="26 KV" b3="TX1LS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61020</SeqNum>
    <Name>Bear Garden.CC</Name>
    <LastEdit Timestamp="2024-06-07T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARGRDN" b2="18 KV" b3="52G-1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARGRDN" b2="18 KV" b3="52G-1B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEARGRDN" b2="18 KV" b3="CT1A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEARGRDN" b2="18 KV" b3="CT1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARGRDN" b2="230 KV" b3="G1A12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARGRDN" b2="230 KV" b3="G1B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARGRDN" b2="230 KV" b3="G1S12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEARGRDN" b2="18 KV" b3="ST1C" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEARGRDN" b2="230 KV" b3="TXGA" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEARGRDN" b2="230 KV" b3="TXGB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEARGRDN" b2="230 KV" b3="TXGC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61030</SeqNum>
    <Name>L230.Bremo-BearGarden.2111</Name>
    <LastEdit Timestamp="2026-01-06T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARGRDN" b2="230 KV" b3="21062111" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEARGRDN" b2="230 KV" b3="2111A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARGRDN" b2="18 KV" b3="52G-1B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEARGRDN" b2="18 KV" b3="CT1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARGRDN" b2="230 KV" b3="G1B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARGRDN" b2="230 KV" b3="G1S12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEARGRDN" b2="18 KV" b3="ST1C" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEARGRDN" b2="230 KV" b3="TXGB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEARGRDN" b2="230 KV" b3="TXGC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="230 KV" b3="211122" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61040</SeqNum>
    <Name>L230.Bremo-BearGarden.2106</Name>
    <LastEdit Timestamp="2026-01-06T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARGRDN" b2="230 KV" b3="21062111" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEARGRDN" b2="230 KV" b3="2106A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARGRDN" b2="18 KV" b3="52G-1A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEARGRDN" b2="18 KV" b3="CT1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARGRDN" b2="230 KV" b3="G1A12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEARGRDN" b2="230 KV" b3="LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEARGRDN" b2="230 KV" b3="TXGA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="230 KV" b3="210622" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61050</SeqNum>
    <Name>L500.PeachBottom-Delta.5034 + Delta.CCs</Name>
    <LastEdit Timestamp="2025-01-10T12:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DLTAPLNT" b2="500 KV" b3="001" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DLTAPLNT" b2="13.8 KV" b3="BKR 1-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DLTAPLNT" b2="13.8 KV" b3="BKR 2-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DLTAPLNT" b2="13.8 KV" b3="BKR 3-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DLTAPLNT" b2="18 KV" b3="BKR 4-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DLTAPLNT" b2="18 KV" b3="BKR 5-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DLTAPLNT" b2="500 KV" b3="BKR 501" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DLTAPLNT" b2="18 KV" b3="BKR 6-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DLTAPLNT" b2="18 KV" b3="BKR 7-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DLTAPLNT" b2="18 KV" b3="CT5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DLTAPLNT" b2="18 KV" b3="CT6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DLTAPLNT" b2="13.8 KV" b3="GEN1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DLTAPLNT" b2="13.8 KV" b3="GEN2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DLTAPLNT" b2="13.8 KV" b3="GEN3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DLTAPLNT" b2="18 KV" b3="GEN4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DLTAPLNT" b2="4 KV" b3="LOAD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DLTAPLNT" b2="18 KV" b3="ST7" />
      <ContingencyEquipment Action="X" Type="XF" b1="DLTAPLNT" b2="500 KV" b3="TR T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DLTAPLNT" b2="500 KV" b3="TR T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="DLTAPLNT" b2="500 KV" b3="TR T3" />
      <ContingencyEquipment Action="X" Type="XF" b1="DLTAPLNT" b2="500 KV" b3="TR T4" />
      <ContingencyEquipment Action="X" Type="XF" b1="DLTAPLNT" b2="500 KV" b3="TR T5" />
      <ContingencyEquipment Action="X" Type="XF" b1="DLTAPLNT" b2="500 KV" b3="TR T6" />
      <ContingencyEquipment Action="X" Type="XF" b1="DLTAPLNT" b2="500 KV" b3="TR T7" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DLTAPLNT" b2="18 KV" b3="TRA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DLTAPLNT" b2="18 KV" b3="TRB" />
      <ContingencyEquipment Action="X" Type="XF" b1="DLTAPLNT" b2="13.8 KV" b3="UAT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="245 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="255 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DLTAPLNT" b2="500 KV" b3="DLT-PEA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61100</SeqNum>
    <Name>L138.Lemoyne-Maclean</Name>
    <LastEdit Timestamp="2024-06-07T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="138 KV" b3="13219" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEMOYNE2" b2="138 KV" b3="LEM-MAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACLEAN" b2="138 KV" b3="B13202" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61170</SeqNum>
    <Name>500/230.Deans.500-2</Name>
    <LastEdit Timestamp="2025-03-20T12:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DEANS" b2="500 KV" b3="500-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="500 KV" b3="SECT 1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="230 KV" b3="SECT 2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="500 KV" b3="SECT 5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="230 KV" b3="SECT 7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61180</SeqNum>
    <Name>500/230.Deans.500-1</Name>
    <LastEdit Timestamp="2025-05-30T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DEANS" b2="500 KV" b3="500-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="500 KV" b3="SECT 1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="230 KV" b3="SECT 2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="500 KV" b3="SECT 3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="230 KV" b3="SECT 5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61190</SeqNum>
    <Name>L138.OakHall-Wattsville.13789</Name>
    <LastEdit Timestamp="2024-11-22T10:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="186" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="187" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKHALL" b2="138 KV" b3="OAK-WAT9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="138 KV" b3="132" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61200</SeqNum>
    <Name>138/69.Wattsville.AT1</Name>
    <LastEdit Timestamp="2024-11-21T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="X" Type="XF" b1="WATTSVIL" b2="138 KV" b3="AT-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61220</SeqNum>
    <Name>L230.Thrasher-Fentress.2128</Name>
    <LastEdit Timestamp="2024-06-07T09:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FENTRES4" b2="230 KV" b3="2128" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="212822" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="269T2128" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THRASHER" b2="230 KV" b3="21102128" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THRASHER" b2="230 KV" b3="231T2128" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61230</SeqNum>
    <Name>L230.Thrasher-Suffolk.2110A + Thrasher.TX3</Name>
    <LastEdit Timestamp="2024-11-13T14:50:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="230 KV" b3="211042" />
      <ContingencyEquipment Action="L" Type="LN" b1="THRASHER" b2="230 KV" b3="2110A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="230 KV" b3="289T2110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THRASHER" b2="230 KV" b3="21102128" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THRASHER" b2="230 KV" b3="279T2110" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="THRASHER" b2="35 KV" b3="CAP3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THRASHER" b2="230 KV" b3="H332" />
      <ContingencyEquipment Action="X" Type="XF" b1="THRASHER" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THRASHER" b2="35 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61240</SeqNum>
    <Name>L230.Thrasher-SNorfolk-Ruritan-ReevesAve.279</Name>
    <LastEdit Timestamp="2025-06-18T13:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="REEVESAV" b2="230 KV" b3="279D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="230 KV" b3="H4T279" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="230 KV" b3="H5T279" />
      <ContingencyEquipment Action="L" Type="LN" b1="SNORFOLK" b2="230 KV" b3="279C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RURITAN" b2="230 KV" b3="H152" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RURITAN" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SNORFOLK" b2="230 KV" b3="279B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SNORFOLK" b2="230 KV" b3="H162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SNORFOLK" b2="230 KV" b3="H362" />
      <ContingencyEquipment Action="X" Type="XF" b1="SNORFOLK" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SNORFOLK" b2="34.5 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SNORFOLK" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SNORFOLK" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THRASHER" b2="230 KV" b3="279T2105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THRASHER" b2="230 KV" b3="279T2110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THRASHER" b2="230 KV" b3="H232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THRASHER" b2="35 KV" b3="L232" />
      <ContingencyEquipment Action="X" Type="XF" b1="THRASHER" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61250</SeqNum>
    <Name>L230.Thrasher-Yadkin.2105 + 230/35.Thrasher.T1</Name>
    <LastEdit Timestamp="2024-06-10T16:39:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="THRASHER" b2="230 KV" b3="231T2105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THRASHER" b2="230 KV" b3="279T2105" />
      <ContingencyEquipment Action="CL" Type="CB" b1="THRASHER" b2="230 KV" b3="H132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THRASHER" b2="35 KV" b3="L132" />
      <ContingencyEquipment Action="CL" Type="CB" b1="THRASHER" b2="35 KV" b3="T122" />
      <ContingencyEquipment Action="X" Type="XF" b1="THRASHER" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="210512" />
      <ContingencyEquipment Action="L" Type="LN" b1="THRASHER" b2="230 KV" b3="2105A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="L2T2105" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61260</SeqNum>
    <Name>L230.Thrasher-StumpyLake-Landstown.231</Name>
    <LastEdit Timestamp="2025-03-28T15:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="230 KV" b3="23152" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANDSTWN" b2="230 KV" b3="231D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="230 KV" b3="231T2026" />
      <ContingencyEquipment Action="L" Type="LN" b1="STUMPYLK" b2="230 KV" b3="231C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUMPYLK" b2="230 KV" b3="H192" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUMPYLK" b2="230 KV" b3="H292" />
      <ContingencyEquipment Action="X" Type="XF" b1="STUMPYLK" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STUMPYLK" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="STUMPYLK" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STUMPYLK" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THRASHER" b2="230 KV" b3="231T2105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THRASHER" b2="230 KV" b3="231T2128" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61310</SeqNum>
    <Name>L230.Aquia Harbor-Garrisonville.2119</Name>
    <LastEdit Timestamp="2025-08-22T10:20:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUAHAR" b2="230 KV" b3="21042119" />
      <ContingencyEquipment Action="L" Type="LN" b1="AQUAHAR" b2="230 KV" b3="AQU-GAR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="AQUAHAR" b2="230 KV" b3="AQU-GAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARRSNV" b2="230 KV" b3="H1T2119" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARRSNV" b2="230 KV" b3="H2T2119" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61320</SeqNum>
    <Name>230/138.IndianRiver.AT22</Name>
    <LastEdit Timestamp="2025-11-04T16:18:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="230 KV" b3="241" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="230 KV" b3="242" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDIANRI" b2="230 KV" b3="AT-22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61330</SeqNum>
    <Name>L230.Arlington-GlenCarlyn.2115</Name>
    <LastEdit Timestamp="2024-06-07T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GLCARLYN" b2="230 KV" b3="2115A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARLINGTN" b2="230 KV" b3="250T2115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARLINGTN" b2="230 KV" b3="273T2115" />
      <ContingencyEquipment Action="X" Type="XF" b1="ARLINGTN" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ARLINGTN" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCARLYN" b2="230 KV" b3="273T2115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLCARLYN" b2="230 KV" b3="278T2115" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLCARLYN" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLCARLYN" b2="35 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61340</SeqNum>
    <Name>230/138.Eddystone.T8</Name>
    <LastEdit Timestamp="2024-06-07T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="138 KV" b3="285 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="230 KV" b3="85 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDDYSTON" b2="230 KV" b3="EDDY 8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61350</SeqNum>
    <Name>L115.TwittysCreek-Madisonvlle-Pamplin+84T154M.Clsd</Name>
    <LastEdit Timestamp="2025-03-18T15:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CURDSVDP" b2="115 KV" b3="149A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="115 KV" b3="8432" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMVILL" b2="115 KV" b3="84A" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAMPLIN" b2="115 KV" b3="154D" />
      <ContingencyEquipment Action="L" Type="LN" b1="MDSNVLDP" b2="115 KV" b3="154E1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MDSNVLDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAMPLIN" b2="115 KV" b3="1006C" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAMPLIN" b2="115 KV" b3="84B" />
      <ContingencyEquipment Action="X" Type="XF" b1="PAMPLIN" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PAMPLIN" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PAMPLIN" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PAMPLIN" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="PAMPLIN" b2="115 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PAMPLIN" b2="24 KV" b3="TX4" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDHSEDP" b2="115 KV" b3="1006B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REDHSEDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STHCREEK" b2="115 KV" b3="1006A" />
      <ContingencyEquipment Action="X" Type="XF" b1="STHCREEK" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STHCREEK" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWITTYCK" b2="115 KV" b3="154T1012" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLISMT" b2="115 KV" b3="14922" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61360</SeqNum>
    <Name>345/138.11Fisk.TR81</Name>
    <LastEdit Timestamp="2025-08-22T10:15:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT1415CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT1516CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="345 KV" b3="BT5-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="11 FISK" b2="345 KV" b3="TR81" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61370</SeqNum>
    <Name>345/138.11Fisk.TR82</Name>
    <LastEdit Timestamp="2024-11-21T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="11 FISK" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="11 FISK" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61380</SeqNum>
    <Name>L345.Crawford-Fisk.1310</Name>
    <LastEdit Timestamp="2024-06-07T10:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="13 CRAWF" b2="345 KV" b3="1310" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="345 KV" b3="BT5-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="345 KV" b3="BT3-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61580</SeqNum>
    <Name>345/138.RedBank.T27 (Sctnlz ACS off/failed)</Name>
    <LastEdit Timestamp="2024-06-07T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="REDBANK" b2="345 KV" b3="27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBANK" b2="138 KV" b3="918" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="REDBANK" b2="345 KV" b3="SW1492" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61600</SeqNum>
    <Name>L138.155Nelson-372Sterling.15511</Name>
    <LastEdit Timestamp="2024-12-12T13:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="155 NELS" b2="138 KV" b3="15511 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="138 KV" b3="L15511CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="372 STER" b2="138 KV" b3="12411CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="372 STER" b2="138 KV" b3="15511 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="372 STER" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="372 STER" b2="138 KV" b3="L15511CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61610</SeqNum>
    <Name>L138.PleasantValley-Hickory-Harper.Q21</Name>
    <LastEdit Timestamp="2025-02-10T13:41:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARPERFE" b2="138 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARPERFE" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARPERFE" b2="138 KV" b3="HAR-HIC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLSNTVLY" b2="138 KV" b3="02P-HIC1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HICKRY" b2="138 KV" b3="SW101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKRY" b2="138 KV" b3="SWR132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HICKRY" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLSNTVLY" b2="138 KV" b3="B13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61620</SeqNum>
    <Name>L138.WestAkron-Brush-Harper</Name>
    <LastEdit Timestamp="2025-05-13T12:55:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HARPERFE" b2="138 KV" b3="BRU-HAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02BRUSH" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02BRUSH" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAKRON" b2="138 KV" b3="WAK-02B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARPERFE" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARPERFE" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WAKRON" b2="138 KV" b3="A39" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKRON" b2="138 KV" b3="B41" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61740</SeqNum>
    <Name>345/230.Waldwick.345-2</Name>
    <LastEdit Timestamp="2024-06-10T16:38:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WALDWICK" b2="345 KV" b3="345-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="345 KV" b3="345SC2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="345 KV" b3="345SC5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="230 KV" b3="SECT1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="230 KV" b3="SECT5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61770</SeqNum>
    <Name>L230.Aldene-Westfield.X-2276</Name>
    <LastEdit Timestamp="2025-01-16T15:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALDENE" b2="230 KV" b3="220-3LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALDENE" b2="230 KV" b3="8-9" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALDENE" b2="230 KV" b3="ALD-WES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALDENE" b2="230 KV" b3="SECT 2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTFIEL" b2="230 KV" b3="230SC1-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTFIEL" b2="230 KV" b3="T-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61780</SeqNum>
    <Name>L230.Hawthorne-HinchmansAve.N-2266</Name>
    <LastEdit Timestamp="2025-07-10T10:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HAWTHORN" b2="230 KV" b3="HAW-HIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAWTHORN" b2="230 KV" b3="N_2266" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINCHMAN" b2="230 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINCHMAN" b2="230 KV" b3="T10HS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HINCHMAN" b2="13 KV" b3="TRANSF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61830</SeqNum>
    <Name>L161.McCrearyCounty-Winfield-Oneida-Hunt</Name>
    <LastEdit Timestamp="2024-11-27T11:05:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNT_TN" b2="161 KV" b3="904" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HUNT_TN" b2="161 KV" b3="909" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCRERYCO" b2="161 KV" b3="PCB1034" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MCRERYCO" b2="161 KV" b3="SW1037" />
      <ContingencyEquipment Action="L" Type="LN" b1="ONEIDA1" b2="161 KV" b3="ONE-HUNT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ONEIDA1" b2="161 KV" b3="XF1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ONEIDA1" b2="161 KV" b3="XF2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WINFLD" b2="161 KV" b3="LD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WINFLD" b2="161 KV" b3="LD2" />
      <ContingencyEquipment Action="L" Type="LN" b1="WINFLD" b2="161 KV" b3="MCC-WIN" />
      <ContingencyEquipment Action="L" Type="LN" b1="WINFLD" b2="161 KV" b3="ONE-WIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61980</SeqNum>
    <Name>L115.BoydtonPlankRd-Boydton-Cloud</Name>
    <LastEdit Timestamp="2024-05-21T14:18:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOYDTNDP" b2="115 KV" b3="BOY-BOYT" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOYDTNDP" b2="115 KV" b3="BOY-CLOU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOYDTNDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOYTNPRD" b2="115 KV" b3="104152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOYTNPRD" b2="115 KV" b3="H2T1041" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="115 KV" b3="104122-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="115 KV" b3="104122-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>61990</SeqNum>
    <Name>345/138.GreenAcres.T4 (NIPS)</Name>
    <LastEdit Timestamp="2025-03-27T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENACR" b2="345 KV" b3="16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENACR" b2="345 KV" b3="17" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENACR" b2="345 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENACR" b2="138 KV" b3="XF4N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENACR" b2="138 KV" b3="XF4S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62010</SeqNum>
    <Name>138/35.Heaton.T1 &amp; 138/13.Heaton.T4 &amp; 8-1 CAP</Name>
    <LastEdit Timestamp="2024-06-07T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="138 KV" b3="140 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="138 KV" b3="315 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="13 KV" b3="4TRLS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="35 KV" b3="50 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HEATON" b2="138 KV" b3="8-1 CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="138 KV" b3="815 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="138 KV" b3="885_CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="HEATON" b2="138 KV" b3="HEA 1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="HEATON" b2="138 KV" b3="HEA 4TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62020</SeqNum>
    <Name>230/138.Heaton.T8</Name>
    <LastEdit Timestamp="2024-06-10T09:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="138 KV" b3="885_CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="HEATON" b2="230 KV" b3="HEA 8TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62030</SeqNum>
    <Name>138/35.Perkiomen.T4 + Cap.7-1</Name>
    <LastEdit Timestamp="2025-09-05T11:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PERKIOME" b2="138 KV" b3="305" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERKIOME" b2="35 KV" b3="445 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERKIOME" b2="138 KV" b3="715 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERKIOME" b2="138 KV" b3="785 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PERKIOME" b2="138 KV" b3="CAP 7-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PERKIOME" b2="138 KV" b3="PER 4TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62040</SeqNum>
    <Name>138/35.Perkiomen.T5</Name>
    <LastEdit Timestamp="2025-09-05T11:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PERKIOME" b2="138 KV" b3="315" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERKIOME" b2="35 KV" b3="555 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERKIOME" b2="138 KV" b3="785 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PERKIOME" b2="138 KV" b3="PERK5TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62100</SeqNum>
    <Name>L138.GreenAcres-StJohns (NIPS)</Name>
    <LastEdit Timestamp="2024-11-19T16:22:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENACR" b2="138 KV" b3="88N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENACR" b2="138 KV" b3="88S" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENACR" b2="138 KV" b3="GRE-STJ2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS" b2="138 KV" b3="88" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS" b2="138 KV" b3="88-00" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62120</SeqNum>
    <Name>230/115.Northwest.230-4</Name>
    <LastEdit Timestamp="2024-12-24T13:44:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="110574CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="110578-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="110579" />
      <ContingencyEquipment Action="X" Type="XF" b1="NRTHWES2" b2="230 KV" b3="230-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="4TR-22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="4TR-26" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62130</SeqNum>
    <Name>230/115.Northwest.230-5</Name>
    <LastEdit Timestamp="2024-12-24T13:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="110560" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="110561" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="110578-5" />
      <ContingencyEquipment Action="X" Type="XF" b1="NRTHWES2" b2="230 KV" b3="230 5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="5TR-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="5TR-11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62140</SeqNum>
    <Name>L138.BlackOak-CrossSchool</Name>
    <LastEdit Timestamp="2025-06-24T08:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKOAK" b2="138 KV" b3="BO12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKOAK" b2="138 KV" b3="BO9" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKOAK" b2="138 KV" b3="BLA-CRS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSSCH" b2="138 KV" b3="CS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSSCH" b2="138 KV" b3="CS3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62200</SeqNum>
    <Name>L138.Ramapo-SouthMahwah (CONED-RECO TIE)</Name>
    <LastEdit Timestamp="2025-02-18T13:02:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="138 KV" b3="FB-2X" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="138 KV" b3="TFB-60-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="51-58-2X" />
      <ContingencyEquipment Action="L" Type="LN" b1="RAMAPO" b2="138 KV" b3="RAM-SMA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="T51-588" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62210</SeqNum>
    <Name>L138.OakStreet-CorporateDrive.702 (NYISO)</Name>
    <LastEdit Timestamp="2024-06-10T09:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CORPORAT" b2="138 KV" b3="5-26-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORPORAT" b2="138 KV" b3="6-26-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKSTRET" b2="138 KV" b3="3-121-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKSTRET" b2="138 KV" b3="4-121-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORPORAT" b2="138 KV" b3="COR-OAKS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62220</SeqNum>
    <Name>L138.CorporateDrive-HaringsCorner.703</Name>
    <LastEdit Timestamp="2024-06-10T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CORPORAT" b2="138 KV" b3="2-26-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORPORAT" b2="138 KV" b3="3-26-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORPORAT" b2="138 KV" b3="COR-HAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARINGSC" b2="138 KV" b3="703-30-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62230</SeqNum>
    <Name>138/69.HaringsCorner.T430</Name>
    <LastEdit Timestamp="2024-06-10T09:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARINGSC" b2="69 KV" b3="702-30-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARINGSC" b2="138 KV" b3="703-30-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARINGSC" b2="138 KV" b3="BK430" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62240</SeqNum>
    <Name>L69.HaringsCorner-WestNyack.701</Name>
    <LastEdit Timestamp="2024-06-10T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARINGSC" b2="69 KV" b3="701-30-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARINGSC" b2="69 KV" b3="HAR-WNY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WNYACK" b2="69 KV" b3="701-21-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62250</SeqNum>
    <Name>L35.HaringsCorner-PearlRiver (RECO-SENY TIE)</Name>
    <LastEdit Timestamp="2024-06-10T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARINGSC" b2="35 KV" b3="45-30-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARINGSC" b2="35 KV" b3="HAR-PEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEARLRIV" b2="35 KV" b3="45-31-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62280</SeqNum>
    <Name>L138.Necessity-TexasEastern-NorthUnion-Bethelboro</Name>
    <LastEdit Timestamp="2025-07-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHELBO" b2="138 KV" b3="NU TP1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NECESSIT" b2="138 KV" b3="BB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NECESSIT" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NECESSIT" b2="138 KV" b3="NEC-TEX" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NUNION" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NUNION" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHELBO" b2="138 KV" b3="BET-NUT" />
      <ContingencyEquipment Action="L" Type="LN" b1="NUNION" b2="138 KV" b3="NUN-NUT" />
      <ContingencyEquipment Action="L" Type="LN" b1="NUTAP1" b2="138 KV" b3="NUT-TEX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TEXASEA5" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62290</SeqNum>
    <Name>L138.Elliotsville-Necessity</Name>
    <LastEdit Timestamp="2025-01-15T17:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELLIOTSV" b2="138 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELLIOTSV" b2="138 KV" b3="CB2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELLIOTSV" b2="138 KV" b3="ELL-NEC" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NECESSIT" b2="138 KV" b3="ELTV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62300</SeqNum>
    <Name>L138.Albright-Brandonville-Elliotsville.104</Name>
    <LastEdit Timestamp="2024-09-30T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBRIGHT" b2="138 KV" b3="ALB-BRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBRIGHT" b2="138 KV" b3="BRANDONV" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ALBRIGHT" b2="138 KV" b3="BRANDRES" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDONV" b2="138 KV" b3="BRA-ELL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRANDONV" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELLIOTSV" b2="138 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELLIOTSV" b2="138 KV" b3="CB3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62320</SeqNum>
    <Name>230/115.Benning.T13</Name>
    <LastEdit Timestamp="2025-04-10T15:56:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="115 KV" b3="13B" />
      <ContingencyEquipment Action="X" Type="XF" b1="BENNING" b2="230 KV" b3="13T" />
      <ContingencyEquipment Action="P" Type="XF" b1="BENNING" b2="115 KV" b3="13T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="6BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="6CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62330</SeqNum>
    <Name>L230.Silver Lake-Marlton-CoxsCorner.U-2247/2302</Name>
    <LastEdit Timestamp="2024-06-10T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COXSCORN" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="COXSCORN" b2="230 KV" b3="COX-MARU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COXSCORN" b2="230 KV" b3="SECT1-5" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARLTON" b2="230 KV" b3="MAR-SIL" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MARLTON" b2="230 KV" b3="T1-2TRAN" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MARLTON" b2="230 KV" b3="T3-4TRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MARLTON" b2="230 KV" b3="TRAN T-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MARLTON" b2="230 KV" b3="TRAN T-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERLA" b2="230 KV" b3="OCB A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62340</SeqNum>
    <Name>L138.Collier-Elwyn.Z-162</Name>
    <LastEdit Timestamp="2024-06-10T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLLIER" b2="138 KV" b3="COL-ELW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="138 KV" b3="Z-162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELWYN" b2="138 KV" b3="Z-162" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62350</SeqNum>
    <Name>L138.BrunotIsland-VeteransBridge-Forbes.Z-46</Name>
    <LastEdit Timestamp="2026-04-17T23:14:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNOTIS" b2="138 KV" b3="BRU-VET" />
      <ContingencyEquipment Action="S" Type="SD" b1="BRUNOTIS" b2="138 KV" b3="Z46" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="Z46FORBS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORBES" b2="138 KV" b3="TIE 25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORBES" b2="138 KV" b3="TIE 53" />
      <ContingencyEquipment Action="L" Type="LN" b1="FORBES" b2="138 KV" b3="FOR-VET" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VETRNBRG" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62360</SeqNum>
    <Name>L138.SaukTrail-Ontwa-Granger-TwinBranch</Name>
    <LastEdit Timestamp="2025-05-12T15:58:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GRANGER" b2="138 KV" b3="GRA-ONT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANGER" b2="138 KV" b3="GRA-TWI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRANGER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRANGER" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANGER" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANGER" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ONTWA" b2="138 KV" b3="T1T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAUKTR" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAUKTR" b2="138 KV" b3="SAU-ONT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="D1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62370</SeqNum>
    <Name>L138.KenzieCreek-Pokagon-SurgesRd-SaukTrail</Name>
    <LastEdit Timestamp="2026-02-20T13:53:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENZIECR" b2="138 KV" b3="KEN-POK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="138 KV" b3="M003Q2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POKAGON" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POKAGON" b2="138 KV" b3="XT4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAUKTR" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SAUKTR" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SURGESRD" b2="138 KV" b3="LAKEHEAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="POKAGON" b2="138 KV" b3="POK-SURG" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAUKTR" b2="138 KV" b3="SAU-SURG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62380</SeqNum>
    <Name>L138.ClinchRiver-VirginiaCityGeneration.2</Name>
    <LastEdit Timestamp="2024-06-10T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLINCHRI" b2="138 KV" b3="CLI-VIR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIRGINIA" b2="138 KV" b3="G1TL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIRGINIA" b2="138 KV" b3="L2TSX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62390</SeqNum>
    <Name>L138.ClinchRiver-VirginiaCityGeneration.1</Name>
    <LastEdit Timestamp="2024-06-10T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLINCHRI" b2="138 KV" b3="CLI-VIR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIRGINIA" b2="138 KV" b3="G1TL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIRGINIA" b2="138 KV" b3="L1TSX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62400</SeqNum>
    <Name>L138.RobisonPark-Wallen</Name>
    <LastEdit Timestamp="2024-06-10T09:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROBISONP" b2="138 KV" b3="ROB-WAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALLEN" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALLEN" b2="138 KV" b3="LOAD XT4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALLEN" b2="138 KV" b3="XT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62420</SeqNum>
    <Name>L230.Greentown-Peru-Walton</Name>
    <LastEdit Timestamp="2026-01-02T11:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="230 KV" b3="21B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="230 KV" b3="222" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENTO2" b2="230 KV" b3="GRE-PER1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERU" b2="69 KV" b3="106-B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERU" b2="69 KV" b3="B1-161" />
      <ContingencyEquipment Action="X" Type="XF" b1="PERU" b2="230 KV" b3="BK1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="PERU" b2="69 KV" b3="BK1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="PERU" b2="13.8 KV" b3="BK1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERU" b2="13.8 KV" b3="CAP BRK" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PERU" b2="13.8 KV" b3="CAPBK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WALTON_3" b2="230 KV" b3="WAL-PER1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALTON_3" b2="230 KV" b3="2021" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALTON_3" b2="230 KV" b3="21B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62430</SeqNum>
    <Name>L230.Greentown-Kokomo.East-Webster</Name>
    <LastEdit Timestamp="2025-05-12T15:54:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="230 KV" b3="222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="230 KV" b3="22B" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENTO2" b2="230 KV" b3="GRE-KOK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KOKOMO_E" b2="69 KV" b3="69230-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="KOKOMO_E" b2="230 KV" b3="BK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KOKOMO_E" b2="230 KV" b3="KOK-WEB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEBSTER" b2="230 KV" b3="22-B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEBSTER" b2="230 KV" b3="B2-22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62440</SeqNum>
    <Name>L138.Greentown-Mier-WabashPSI(CIN/MISO)</Name>
    <LastEdit Timestamp="2026-03-12T07:47:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENTO2" b2="138 KV" b3="GRE-MIE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIER" b2="138 KV" b3="MIE-MIE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WABASPSI" b2="138 KV" b3="WAB-MIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WABASPSI" b2="138 KV" b3="48-B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WABASPSI" b2="138 KV" b3="B3-48" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62450</SeqNum>
    <Name>L138.Greentown-Maple-Chrysler</Name>
    <LastEdit Timestamp="2025-10-20T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08CHRYSL" b2="138 KV" b3="11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENTO2" b2="138 KV" b3="GRE-MAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAPLECIN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAPLECIN" b2="138 KV" b3="MAP-08C1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62460</SeqNum>
    <Name>L138.Greentown-Delco</Name>
    <LastEdit Timestamp="2024-06-10T09:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELCOCIN" b2="138 KV" b3="10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENTO2" b2="138 KV" b3="GRE-DEL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62470</SeqNum>
    <Name>L345.153Taylor-11Fisk.15324</Name>
    <LastEdit Timestamp="2024-06-11T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="153 TAYL" b2="345 KV" b3="15324 X" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="345 KV" b3="BT1-7 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62480</SeqNum>
    <Name>L138.Bayshore-BPHusky.1</Name>
    <LastEdit Timestamp="2025-08-06T14:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="138 KV" b3="B13252" />
      <ContingencyEquipment Action="L" Type="LN" b1="BP_HUSKY" b2="138 KV" b3="BAY-BP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BP_HUSKY" b2="138 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BP_HUSKY" b2="138 KV" b3="B16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62490</SeqNum>
    <Name>L138.Bayshore-BPHusky.2</Name>
    <LastEdit Timestamp="2025-08-06T14:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="138 KV" b3="B13254" />
      <ContingencyEquipment Action="L" Type="LN" b1="BP_HUSKY" b2="138 KV" b3="BAY-BP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BP_HUSKY" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BP_HUSKY" b2="138 KV" b3="B13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62500</SeqNum>
    <Name>L138.BPHusky-Frey-Lemoyne</Name>
    <LastEdit Timestamp="2025-03-27T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BP_HUSKY" b2="138 KV" b3="BPH-02F2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02FREY" b2="138 KV" b3="CS13402" />
      <ContingencyEquipment Action="L" Type="LN" b1="02FREY" b2="138 KV" b3="FRY-LEM1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02FREY" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BP_HUSKY" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BP_HUSKY" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="138 KV" b3="13214" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62510</SeqNum>
    <Name>L138.BPHusky-FtIndustry-Sterpip-Smuckers-Jackman</Name>
    <LastEdit Timestamp="2025-07-25T16:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02FORTIN" b2="138 KV" b3="3407" />
      <ContingencyEquipment Action="L" Type="LN" b1="BP_HUSKY" b2="138 KV" b3="BPH-02F1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STERPIP" b2="138 KV" b3="STE-02F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02FORTIN" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BP_HUSKY" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BP_HUSKY" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKMAN" b2="138 KV" b3="3330" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKMAN" b2="138 KV" b3="JAC-SMU2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SMUCKERS" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERPIP" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STERPIP" b2="138 KV" b3="LD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STERPIP" b2="138 KV" b3="STE-SMU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62520</SeqNum>
    <Name>L138.Shepherdstown-SleepyHollow</Name>
    <LastEdit Timestamp="2025-02-10T11:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHEPERDS" b2="138 KV" b3="SLEEPYHO" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHEPERDS" b2="138 KV" b3="SHE-SLE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SLEEPYHO" b2="138 KV" b3="SHEP DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SLEEPYHO" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62530</SeqNum>
    <Name>230/115.Benning.T14</Name>
    <LastEdit Timestamp="2025-04-10T15:56:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="115 KV" b3="14B" />
      <ContingencyEquipment Action="X" Type="XF" b1="BENNING" b2="230 KV" b3="14T" />
      <ContingencyEquipment Action="P" Type="XF" b1="BENNING" b2="115 KV" b3="14T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="5BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="5CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62540</SeqNum>
    <Name>230/66.Mountain.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-06-14T08:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MOUN UGI" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66240" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66270" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="230 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62550</SeqNum>
    <Name>230/66.Mountain.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-06-14T08:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MOUN UGI" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="230 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62580</SeqNum>
    <Name>500/138.Cabot.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-06-14T08:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C11" />
      <ContingencyEquipment Action="X" Type="XF" b1="CABOT" b2="500 KV" b3="TRAN  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="500 KV" b3="XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62590</SeqNum>
    <Name>500/138.Cabot.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-06-14T08:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C19" />
      <ContingencyEquipment Action="X" Type="XF" b1="CABOT" b2="500 KV" b3="TRAN  3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CABOT" b2="500 KV" b3="XF3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62610</SeqNum>
    <Name>69/13.Roxborough.T4</Name>
    <LastEdit Timestamp="2024-12-31T13:19:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBOROU" b2="69 KV" b3="125 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBOROU" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBOROU" b2="69 KV" b3="745" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROXBOROU" b2="69 KV" b3="ROX 4TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62620</SeqNum>
    <Name>L138.Kammer-BigGrave-Aston</Name>
    <LastEdit Timestamp="2024-06-11T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTON" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASTON" b2="138 KV" b3="AST-BIG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIGGRAVE" b2="138 KV" b3="BIG-KAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="D2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62630</SeqNum>
    <Name>L138.Sandhill-FTHenry-Dixon-Tidd</Name>
    <LastEdit Timestamp="2024-11-15T11:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DIXON" b2="138 KV" b3="DIX-TID" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DIXON" b2="138 KV" b3="TUNELRID" />
      <ContingencyEquipment Action="L" Type="LN" b1="DIXON" b2="138 KV" b3="DIX-FTH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FTHENRY" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="FTHENRY" b2="138 KV" b3="FTH-SAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62650</SeqNum>
    <Name>L230.Northwest-Northwest2.2370</Name>
    <LastEdit Timestamp="2024-06-11T13:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWES" b2="230 KV" b3="2370CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="2370-22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="2370-26" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHWES" b2="230 KV" b3="NOR-NOR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62660</SeqNum>
    <Name>L230.Northwest-Northwest2.2371</Name>
    <LastEdit Timestamp="2024-06-11T13:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWES" b2="230 KV" b3="2371CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="2371-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="230 KV" b3="2371-11" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHWES" b2="230 KV" b3="NOR-NOR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62680</SeqNum>
    <Name>Ladysmith.CT1</Name>
    <LastEdit Timestamp="2024-06-11T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="LADYSMCT" b2="14 KV" b3="GT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMCT" b2="230 KV" b3="GT172" />
      <ContingencyEquipment Action="X" Type="XF" b1="LADYSMCT" b2="230 KV" b3="TXG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62690</SeqNum>
    <Name>Ladysmith.CT2</Name>
    <LastEdit Timestamp="2024-06-11T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="LADYSMCT" b2="14 KV" b3="GT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMCT" b2="230 KV" b3="GT272" />
      <ContingencyEquipment Action="X" Type="XF" b1="LADYSMCT" b2="230 KV" b3="TXG2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62700</SeqNum>
    <Name>Ladysmith.CT3</Name>
    <LastEdit Timestamp="2024-06-11T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="LADYSMCT" b2="18 KV" b3="GT3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMCT" b2="230 KV" b3="GT372" />
      <ContingencyEquipment Action="X" Type="XF" b1="LADYSMCT" b2="230 KV" b3="TXG3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62710</SeqNum>
    <Name>Ladysmith.CT4</Name>
    <LastEdit Timestamp="2024-06-11T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="LADYSMCT" b2="18 KV" b3="GT4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMCT" b2="230 KV" b3="GT472" />
      <ContingencyEquipment Action="X" Type="XF" b1="LADYSMCT" b2="230 KV" b3="TXG4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62720</SeqNum>
    <Name>Ladysmith.CT5</Name>
    <LastEdit Timestamp="2024-06-11T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="LADYSMCT" b2="18 KV" b3="GT5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMCT" b2="230 KV" b3="GT572" />
      <ContingencyEquipment Action="X" Type="XF" b1="LADYSMCT" b2="230 KV" b3="TXG5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62730</SeqNum>
    <Name>L345.MaddoxCreek-BlueCreek + BlueCreek.WF</Name>
    <LastEdit Timestamp="2024-06-11T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUECREE" b2="345 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUECREE" b2="345 KV" b3="7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BLUECREE" b2="34.5 KV" b3="BLUEC1WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BLUECREE" b2="34.5 KV" b3="BLUEC2WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BLUECREE" b2="34.5 KV" b3="BLUEC3WF" />
      <ContingencyEquipment Action="S" Type="SD" b1="BLUECREE" b2="115 KV" b3="BLUEC_SD" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUECREE" b2="115 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUECREE" b2="115 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUECREE" b2="115 KV" b3="T3" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUECREE" b2="345 KV" b3="TR.SP" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUECREE" b2="345 KV" b3="TR60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADDOXCR" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADDOXCR" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MADDOXCR" b2="345 KV" b3="BLU-MAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62740</SeqNum>
    <Name>L230.Lewistown-Yeagertown.2016</Name>
    <LastEdit Timestamp="2025-10-27T14:51:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B91" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YEAGERTO" b2="230 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YEAGERTO" b2="230 KV" b3="B29" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEWISTOW" b2="230 KV" b3="LEW-YEA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62750</SeqNum>
    <Name>L230.Lewistown-Yeagertown.2028</Name>
    <LastEdit Timestamp="2025-07-22T13:30:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YEAGERTO" b2="230 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YEAGERTO" b2="230 KV" b3="B34" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEWISTOW" b2="230 KV" b3="LEW-YEA2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62770</SeqNum>
    <Name>L230.PleasantView-DryMill-BKT-Hamilton.2098</Name>
    <LastEdit Timestamp="2025-02-18T15:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRZYKNOL" b2="230 KV" b3="2098A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRZYKNOL" b2="230 KV" b3="2098C" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRZYKNOL" b2="230 KV" b3="2098A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMILTN" b2="230 KV" b3="H162" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAMILTN" b2="34.5 KV" b3="LD-XF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HAMILTN" b2="230 KV" b3="SR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMILTN" b2="230 KV" b3="SR162" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAMILTN" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="230 KV" b3="20982180" />
      <ContingencyEquipment Action="L" Type="LN" b1="DRYMILL" b2="230 KV" b3="2098B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="230 KV" b3="274T2098" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="230 KV" b3="H122" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLEASNTV" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLEASNTV" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62780</SeqNum>
    <Name>Ironwood.CC</Name>
    <LastEdit Timestamp="2024-06-14T08:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONWOOD" b2="230 KV" b3="52-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONWOOD" b2="230 KV" b3="52-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONWOOD" b2="230 KV" b3="52-5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="IRONWOOD" b2="16 KV" b3="CT-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="IRONWOOD" b2="16 KV" b3="CT-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="IRONWOOD" b2="16 KV" b3="ST" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62800</SeqNum>
    <Name>L138.ShadyOaks-Mendota.13901</Name>
    <LastEdit Timestamp="2025-07-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="100 SHAD" b2="138 KV" b3="13901" />
      <ContingencyEquipment Action="OP" Type="CB" b1="100 SHAD" b2="138 KV" b3="L13901CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="139 MEND" b2="34.5 KV" b3="13931" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="139 MEND" b2="34.5 KV" b3="13934 LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="139 MEND" b2="34.5 KV" b3="13938" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="139 MEND" b2="34.5 KV" b3="CAPBANK1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="139 MEND" b2="34.5 KV" b3="CAPBANK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="139 MEND" b2="34.5 KV" b3="L13938CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="139 MEND" b2="138 KV" b3="TR78" />
      <ContingencyEquipment Action="U" Type="GEN" b1="139 MEND" b2="34.5 KV" b3="WBROOKWF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62830</SeqNum>
    <Name>L138.RedLion-Reybold.13818</Name>
    <LastEdit Timestamp="2024-06-11T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DELA DPL" b2="138 KV" b3="DEL-REY3" />
      <ContingencyEquipment Action="X" Type="XF" b1="DELA DPL" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDLION" b2="138 KV" b3="RED-REY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 134" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62840</SeqNum>
    <Name>L138.Rehoboth-Robinsonville.13706</Name>
    <LastEdit Timestamp="2024-06-11T13:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REHOBOTH" b2="138 KV" b3="155" />
      <ContingencyEquipment Action="X" Type="XF" b1="REHOBOTH" b2="138 KV" b3="AT-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="REHOBOTH" b2="138 KV" b3="REH-ROB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBINS" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBINS" b2="138 KV" b3="131" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62850</SeqNum>
    <Name>L138.Silverbrook-WestWilmington.13827</Name>
    <LastEdit Timestamp="2024-06-11T13:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERBR" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="L" Type="LN" b1="SILVERBR" b2="138 KV" b3="SIL-WWI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWILMING" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWILMING" b2="138 KV" b3="133" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62860</SeqNum>
    <Name>L138.Taylor-ICAir.15312</Name>
    <LastEdit Timestamp="2024-06-14T08:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="153 TAYL" b2="138 KV" b3="15312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="745 IC A" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62870</SeqNum>
    <Name>L138.Taylor-ICAir.15313</Name>
    <LastEdit Timestamp="2024-06-14T08:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="153 TAYL" b2="138 KV" b3="15313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="745 IC A" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62880</SeqNum>
    <Name>L138.Taylor-Sears.15304</Name>
    <LastEdit Timestamp="2024-06-14T08:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="153 TAYL" b2="138 KV" b3="15304" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT1-6 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="784 SEAR" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62890</SeqNum>
    <Name>L138.Taylor-Sears.15305</Name>
    <LastEdit Timestamp="2024-06-14T08:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="153 TAYL" b2="138 KV" b3="15305" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT3031CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="784 SEAR" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62900</SeqNum>
    <Name>L138.Taylor-Sears.15307</Name>
    <LastEdit Timestamp="2024-06-14T08:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="153 TAYL" b2="138 KV" b3="15307" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT7-12CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="784 SEAR" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62910</SeqNum>
    <Name>L138.Sabrooke-Rockford.98221 + 982Rockford.CT21</Name>
    <LastEdit Timestamp="2024-06-14T08:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="194 SABR" b2="138 KV" b3="98221" />
      <ContingencyEquipment Action="OP" Type="CB" b1="194 SABR" b2="138 KV" b3="L98221CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="982 ROCK" b2="16 KV" b3="RO21" />
      <ContingencyEquipment Action="X" Type="XF" b1="982 ROCK" b2="138 KV" b3="TR21 16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="982 ROCK" b2="138 KV" b3="TR21 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62920</SeqNum>
    <Name>L138.94Haumesser-961LeeDekalb.96101 + LeeDekalb.WF</Name>
    <LastEdit Timestamp="2024-12-05T16:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="94 HAURD" b2="138 KV" b3="L96101CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="961 LEE" b2="138 KV" b3="52-T" />
      <ContingencyEquipment Action="L" Type="LN" b1="94 HAURD" b2="138 KV" b3="96101" />
      <ContingencyEquipment Action="U" Type="GEN" b1="961 LEE" b2="34.5 KV" b3="LEEDKBS" />
      <ContingencyEquipment Action="U" Type="GEN" b1="961 LEE" b2="34.5 KV" b3="LEEDKWF1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="961 LEE" b2="34.5 KV" b3="LEEDKWF2" />
      <ContingencyEquipment Action="X" Type="XF" b1="961 LEE" b2="138 KV" b3="TR76" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62930</SeqNum>
    <Name>L138.EastDanville-RockSprings</Name>
    <LastEdit Timestamp="2026-04-14T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EDANVILL" b2="138 KV" b3="EDA-ROCK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDANVILL" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKSPRG" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62950</SeqNum>
    <Name>230/138.Cumberland.T3 (AE)</Name>
    <LastEdit Timestamp="2024-09-20T15:14:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="230 KV" b3="BUSGCBA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="138 KV" b3="BUSGCBJ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="138 KV" b3="BUSGCBL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB AE" b2="230 KV" b3="BUSGCBR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CUMB AE" b2="230 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62980</SeqNum>
    <Name>138/69.BasinRoad.AT1</Name>
    <LastEdit Timestamp="2024-06-14T08:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="69 KV" b3="65" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="69 KV" b3="66" />
      <ContingencyEquipment Action="X" Type="XF" b1="BASINRD" b2="138 KV" b3="AT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>62990</SeqNum>
    <Name>138/69.Carrcroft.AT1</Name>
    <LastEdit Timestamp="2024-06-14T08:24:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARRCROF" b2="138 KV" b3="141" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARRCROF" b2="138 KV" b3="142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARRCROF" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARRCROF" b2="138 KV" b3="AT-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63000</SeqNum>
    <Name>L69.Carrcroft-SilversideRoad.6831</Name>
    <LastEdit Timestamp="2024-06-14T08:38:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARRCROF" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARRCROF" b2="69 KV" b3="CAR-SIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERSI" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERSI" b2="69 KV" b3="65" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63010</SeqNum>
    <Name>L69.Kiamensi-West.6828</Name>
    <LastEdit Timestamp="2025-04-30T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="L" Type="LN" b1="KIAMENSI" b2="69 KV" b3="KIA-WES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="69 KV" b3="62 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="69 KV" b3="65 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63020</SeqNum>
    <Name>138/69.OceanBay.AT1</Name>
    <LastEdit Timestamp="2024-06-14T08:25:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANBAY" b2="138 KV" b3="171" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANBAY" b2="138 KV" b3="172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANBAY" b2="69 KV" b3="68" />
      <ContingencyEquipment Action="X" Type="XF" b1="OCEANBAY" b2="138 KV" b3="AT-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63030</SeqNum>
    <Name>L69.OceanBay-Maridel-OceanCity.6723</Name>
    <LastEdit Timestamp="2024-06-14T08:39:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARIDEL" b2="69 KV" b3="68" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARIDEL" b2="69 KV" b3="7220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARIDEL" b2="69 KV" b3="7360" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MARIDEL" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MARIDEL" b2="69 KV" b3="CAP2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARIDEL" b2="69 KV" b3="LOADT1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARIDEL" b2="69 KV" b3="LOADT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANBAY" b2="69 KV" b3="68" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARIDEL" b2="69 KV" b3="MRD-OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANCTY" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARIDEL" b2="69 KV" b3="MRD-OCC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63040</SeqNum>
    <Name>138/69.Rehoboth.AT1</Name>
    <LastEdit Timestamp="2024-06-14T08:29:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REHOBOTH" b2="138 KV" b3="155" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REHOBOTH" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REHOBOTH" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="X" Type="XF" b1="REHOBOTH" b2="138 KV" b3="AT-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63050</SeqNum>
    <Name>138/69.Byberry.T3&amp;T4</Name>
    <LastEdit Timestamp="2024-06-14T08:24:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BYBERRY" b2="138 KV" b3="110 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BYBERRY" b2="69 KV" b3="70 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BYBERRY" b2="138 KV" b3="BYB3TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="BYBERRY" b2="138 KV" b3="BYB4TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63060</SeqNum>
    <Name>230/138.PlymouthMeeting.T9</Name>
    <LastEdit Timestamp="2024-06-14T08:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="230 KV" b3="195 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUTH" b2="138 KV" b3="995 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLYMOUTH" b2="230 KV" b3="PLY 9TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63080</SeqNum>
    <Name>230/69.Planebrook.T8</Name>
    <LastEdit Timestamp="2024-06-17T14:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="69 KV" b3="815" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="885" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLANEBRO" b2="230 KV" b3="PLA 8TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63090</SeqNum>
    <Name>138/69.Eddystone.T5</Name>
    <LastEdit Timestamp="2024-06-18T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="138 KV" b3="55 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="69 KV" b3="585 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDDYSTON" b2="138 KV" b3="EDD 5TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDDYSTON" b2="69 KV" b3="EDD-SCO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDDYSTON" b2="69 KV" b3="IBUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63100</SeqNum>
    <Name>138/69.Master.T1</Name>
    <LastEdit Timestamp="2024-06-18T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MASTER" b2="138 KV" b3="15 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASTER" b2="69 KV" b3="265 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MASTER" b2="138 KV" b3="MAS 1TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="MASTER" b2="69 KV" b3="MAS-WMO6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63150</SeqNum>
    <Name>L138.Blaine-WestLake</Name>
    <LastEdit Timestamp="2024-06-17T14:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLAINE" b2="138 KV" b3="BLAI-WES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAINE" b2="138 KV" b3="C_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTLAKE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTLAKE" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63160</SeqNum>
    <Name>L138.Hancock-CaveSpring-Strk-PoagesMill-MattFunk.2</Name>
    <LastEdit Timestamp="2024-06-18T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CAVESPRI" b2="138 KV" b3="CAV-STA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAVESPRI" b2="138 KV" b3="CAV-HAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="G2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MATTFUN2" b2="138 KV" b3="MAT-POA" />
      <ContingencyEquipment Action="L" Type="LN" b1="POAGESMI" b2="138 KV" b3="POA-STA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POAGESMI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STARKEY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STARKEY" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63170</SeqNum>
    <Name>L138.ClinchRiver-VirginiaCity [EON]</Name>
    <LastEdit Timestamp="2024-06-18T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="VRGNACTY" b2="138 KV" b3="12V-CLI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VRGNACTY" b2="138 KV" b3="CB704" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63180</SeqNum>
    <Name>L138.AllenIM-Tillman-TimberRoad</Name>
    <LastEdit Timestamp="2024-11-14T15:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENIM" b2="138 KV" b3="ALL-TIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TILLMAN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TILLMAN" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TIMBERRD" b2="138 KV" b3="TIL-TIM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMBERRD" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMBERRD" b2="138 KV" b3="C1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63190</SeqNum>
    <Name>TimberRoad.WF1&amp;2</Name>
    <LastEdit Timestamp="2024-06-17T14:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TIMBERRD" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMBERRD" b2="138 KV" b3="CB1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TIMBERRD" b2="34.5 KV" b3="TIMR2WF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63200</SeqNum>
    <Name>L345.MeadowLake-MeadowLake4 + MeadowLake.WF4&amp;5&amp;6</Name>
    <LastEdit Timestamp="2025-05-05T13:11:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWL4" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWL4" b2="345 KV" b3="BT1-2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MEADOWL4" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADOWLK" b2="345 KV" b3="MEA-MEA4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEADOWL4" b2="34.5 KV" b3="MEDLK4WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEADOWL4" b2="34.5 KV" b3="MEDLK5WF" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEADOWL4" b2="345 KV" b3="T-1GSU" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MEADOWL6" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEADOWL6" b2="345 KV" b3="GSU" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADOWL4" b2="345 KV" b3="MEA-MEA6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEADOWL6" b2="34.5 KV" b3="MEDLK6WF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWLK" b2="345 KV" b3="BT1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWLK" b2="345 KV" b3="BT2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63210</SeqNum>
    <Name>L138.Roberts-WestCampus</Name>
    <LastEdit Timestamp="2024-06-18T10:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="K1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROBERTS2" b2="138 KV" b3="ROB-WCAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCAMPUS" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCAMPUS" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63220</SeqNum>
    <Name>L138.LapelJct-Noblesville [CIN]</Name>
    <LastEdit Timestamp="2024-06-18T09:59:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="08LAPLJT" b2="138 KV" b3="08L-NOB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08LAPLJT" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOBLESVI" b2="138 KV" b3="86" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63230</SeqNum>
    <Name>L138.SouthAnderson-LapelJct [CIN]</Name>
    <LastEdit Timestamp="2024-06-18T10:15:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08LAPLJT" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="08LAPLJT" b2="138 KV" b3="08L-SAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDERSO" b2="138 KV" b3="1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDERSO" b2="138 KV" b3="8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63240</SeqNum>
    <Name>L138.MorganFork-HaysBranch</Name>
    <LastEdit Timestamp="2024-06-18T10:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAYSBRCH" b2="138 KV" b3="KENTUCKY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANFK" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORGANFK" b2="138 KV" b3="HAY-MOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63250</SeqNum>
    <Name>Dennis.SVC</Name>
    <LastEdit Timestamp="2024-06-17T14:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="DENNIS" b2="230 KV" b3="DENN SVC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="230 KV" b3="GCB C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63290</SeqNum>
    <Name>L69.Mickleton-Valero</Name>
    <LastEdit Timestamp="2024-12-03T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="HH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="JJ" />
      <ContingencyEquipment Action="L" Type="LN" b1="MICKLETO" b2="69 KV" b3="MIC-VAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALERO" b2="69 KV" b3="OCB 8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63300</SeqNum>
    <Name>DelcoTap.DRMI.Unit</Name>
    <LastEdit Timestamp="2024-06-18T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DELCOTAP" b2="230 KV" b3="1 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELCOTAP" b2="230 KV" b3="185 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELCOTAP" b2="13 KV" b3="DELCO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63310</SeqNum>
    <Name>230/138.Monroe.T4 (AE)</Name>
    <LastEdit Timestamp="2024-06-18T09:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="230 KV" b3="BUSOCBDD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="230 KV" b3="LL" />
      <ContingencyEquipment Action="X" Type="XF" b1="MONR AE" b2="230 KV" b3="MON #4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="138 KV" b3="XFMROCBH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="138 KV" b3="XFMROCBM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63320</SeqNum>
    <Name>230/35.Cecil.T3</Name>
    <LastEdit Timestamp="2024-06-17T14:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CECIL" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CECIL" b2="230 KV" b3="233" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CECIL" b2="35 KV" b3="60" />
      <ContingencyEquipment Action="X" Type="XF" b1="CECIL" b2="230 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63330</SeqNum>
    <Name>138/35.Cecil.T2</Name>
    <LastEdit Timestamp="2024-06-17T12:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CECIL" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CECIL" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CECIL" b2="35 KV" b3="80" />
      <ContingencyEquipment Action="X" Type="XF" b1="CECIL" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63340</SeqNum>
    <Name>L69.IndianRiver-Millsboro.6720</Name>
    <LastEdit Timestamp="2026-03-19T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="69 KV" b3="66" />
      <ContingencyEquipment Action="L" Type="LN" b1="INDIANRI" b2="69 KV" b3="IND-MIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILSBORO" b2="69 KV" b3="7410" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILSBORO" b2="69 KV" b3="7420" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63360</SeqNum>
    <Name>L500.Midlothian-NorthAnna.576</Name>
    <LastEdit Timestamp="2024-06-18T10:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLOTH" b2="500 KV" b3="563T576" />
      <ContingencyEquipment Action="L" Type="LN" b1="NANNA4" b2="500 KV" b3="576A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLOTH" b2="500 KV" b3="H6T576" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="500 KV" b3="57602" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="500 KV" b3="WT576" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63370</SeqNum>
    <Name>L500.Loudoun-Mosby.502A</Name>
    <LastEdit Timestamp="2025-07-14T15:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="500 KV" b3="502T535" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="500 KV" b3="H2T502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSBY" b2="500 KV" b3="50272" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOUDOUN4" b2="500 KV" b3="502A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSBY" b2="500 KV" b3="502T546" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63380</SeqNum>
    <Name>L69.WestCambridge-Airey-Vienna.6709</Name>
    <LastEdit Timestamp="2026-04-14T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AIREY" b2="69 KV" b3="AIR-VIEN" />
      <ContingencyEquipment Action="L" Type="LN" b1="AIREY" b2="69 KV" b3="AIR-WCA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AIREY" b2="69 KV" b3="AIREY" />
      <ContingencyEquipment Action="U" Type="GEN" b1="AIREY" b2="69 KV" b3="AIREYSLR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCAMBRID" b2="69 KV" b3="61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63390</SeqNum>
    <Name>L69.DarleyRoad-SilversideRoad.6833</Name>
    <LastEdit Timestamp="2024-06-18T10:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARLEYRD" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARLEYRD" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARLEYRD" b2="69 KV" b3="DAR-SIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERSI" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERSI" b2="69 KV" b3="67" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63400</SeqNum>
    <Name>230/69.Cartanza.AT1 + L69.Cartanza-NorthSt.1</Name>
    <LastEdit Timestamp="2024-06-18T09:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTANZA" b2="230 KV" b3="230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTANZA" b2="230 KV" b3="236" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARTANZA" b2="230 KV" b3="AT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARTANZA" b2="69 KV" b3="CAR-NOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHST" b2="69 KV" b3="2060" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHST" b2="69 KV" b3="2070" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63410</SeqNum>
    <Name>230/69.Cartanza.AT2 + L69.Cartanza-NorthSt.2</Name>
    <LastEdit Timestamp="2024-06-18T09:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTANZA" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTANZA" b2="230 KV" b3="234" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARTANZA" b2="230 KV" b3="AT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARTANZA" b2="69 KV" b3="CAR-NOR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHST" b2="69 KV" b3="2050" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHST" b2="69 KV" b3="2060" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63420</SeqNum>
    <Name>L138.Farmview-Milford.13773</Name>
    <LastEdit Timestamp="2024-06-18T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVIEW" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVIEW" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="138 KV" b3="8610" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="138 KV" b3="8620" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMVIEW" b2="138 KV" b3="FRM-MIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63430</SeqNum>
    <Name>L138.Farmview-SouthHarrington.13774</Name>
    <LastEdit Timestamp="2024-06-18T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVIEW" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVIEW" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMVIEW" b2="138 KV" b3="FRM-SHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="138 KV" b3="8350" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARRING" b2="138 KV" b3="8360" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63440</SeqNum>
    <Name>Edgemoor.HayRoad.CC8+3</Name>
    <LastEdit Timestamp="2024-06-18T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEMOOR" b2="230 KV" b3="EDG-RED" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="13 KV" b3="HAYRD5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="13 KV" b3="HAYRD6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="13 KV" b3="HAYRD7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDGEMOOR" b2="18 KV" b3="HAYRD8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="230 KV" b3="L1" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="230 KV" b3="T50" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="230 KV" b3="T60" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="230 KV" b3="T70" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDGEMOOR" b2="230 KV" b3="T80" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63510</SeqNum>
    <Name>L230.CedarGrove-Clifton-Athenia.B-2228</Name>
    <LastEdit Timestamp="2024-06-18T10:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="2-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="4-9" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATHENIA" b2="230 KV" b3="ATH-CLIB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARGRO" b2="230 KV" b3="CED-CLIB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CLIF PS" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLIF PS" b2="230 KV" b3="TRAN T-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63520</SeqNum>
    <Name>L230.CedarGrove-Clifton-Athenia.K-2263</Name>
    <LastEdit Timestamp="2024-06-19T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="2-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="4-11" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATHENIA" b2="230 KV" b3="ATH-CLIK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="230 KV" b3="1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARGRO" b2="230 KV" b3="CED-CLIK" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CLIF PS" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLIF PS" b2="230 KV" b3="TRAN T-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63530</SeqNum>
    <Name>BearRock.WF + 230/34.BearRock.T1</Name>
    <LastEdit Timestamp="2026-05-08T15:05:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="BEARROCK" b2="34.5 KV" b3="ARIDGWF1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARROCK" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARROCK" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEARROCK" b2="230 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEARROCK" b2="34.5 KV" b3="NALLGHWF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEARROCK" b2="34.5 KV" b3="P22A WF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63540</SeqNum>
    <Name>L230.Morristown-Tewksbury (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-31T08:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISTO" b2="230 KV" b3="B83" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MORRISTO" b2="230 KV" b3="BK 5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TEWKSBRY" b2="230 KV" b3="1135LB15" />
      <ContingencyEquipment Action="L" Type="LN" b1="TEWKSBRY" b2="230 KV" b3="MOR-TEW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63550</SeqNum>
    <Name>L230.Gilbert-Tewksbury (Sctnlz)</Name>
    <LastEdit Timestamp="2024-06-19T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GILBERT" b2="230 KV" b3="C2003 DI" />
      <ContingencyEquipment Action="L" Type="LN" b1="TEWKSBRY" b2="230 KV" b3="GIL-TEW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TEWKSBRY" b2="230 KV" b3="1135LB14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63570</SeqNum>
    <Name>L115.Hooversville-StatlerHill</Name>
    <LastEdit Timestamp="2025-05-15T09:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOOVERSV" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOOVERSV" b2="115 KV" b3="HOO-STA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STATHILL" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STATHILL" b2="115 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63580</SeqNum>
    <Name>L115.ColverPower-Glory + ColverPower.NUG</Name>
    <LastEdit Timestamp="2025-08-11T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="COLVERPO" b2="115 KV" b3="115_13" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COLVERPO" b2="115 KV" b3="CLVR" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLVERPO" b2="115 KV" b3="COL-GLO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLVERPO" b2="115 KV" b3="GLORY115" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COLVERPO" b2="13 KV" b3="NUG GE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLORY" b2="115 KV" b3="B16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63660</SeqNum>
    <Name>345/138.MattFunk.T2</Name>
    <LastEdit Timestamp="2024-06-19T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MATTFUN2" b2="345 KV" b3=".  2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="K2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63680</SeqNum>
    <Name>345/230.Waldwick.T3</Name>
    <LastEdit Timestamp="2024-06-19T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WALDWICK" b2="345 KV" b3="345-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="345 KV" b3="345SC2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="345 KV" b3="345SC7-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="230 KV" b3="SECT1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDWICK" b2="230 KV" b3="SECT7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63690</SeqNum>
    <Name>L138.Collinwood-NineMile</Name>
    <LastEdit Timestamp="2024-06-19T14:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="02COLLIN" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02COLLIN" b2="138 KV" b3="CS-CAP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="02COLLIN" b2="138 KV" b3="DS1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NINEMILE" b2="138 KV" b3="NIN-COL" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NINEMILE" b2="138 KV" b3="NMCD-DS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63730</SeqNum>
    <Name>500/230.BurchesHill.T3</Name>
    <LastEdit Timestamp="2024-06-19T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="500 KV" b3="12A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="500 KV" b3="12B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="6B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="230 KV" b3="6C" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURCHESH" b2="500 KV" b3="NO.3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63750</SeqNum>
    <Name>L138.Thelma-Dewey</Name>
    <LastEdit Timestamp="2025-11-06T10:49:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEWEY" b2="138 KV" b3="A003M8" />
      <ContingencyEquipment Action="X" Type="XF" b1="THELMA" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="THELMA" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="THELMA" b2="46 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA" b2="46 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA" b2="138 KV" b3="BB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="THELMA" b2="138 KV" b3="CAPA" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEWEY" b2="138 KV" b3="DEW-THE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63820</SeqNum>
    <Name>L500.Cranberry-WylieRidge</Name>
    <LastEdit Timestamp="2025-06-04T14:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="500 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="500 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRANBERY" b2="500 KV" b3="CRA-WYL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="500 KV" b3="WL4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="500 KV" b3="WL5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63850</SeqNum>
    <Name>L138.Sheffild-Amoco (NIPS)</Name>
    <LastEdit Timestamp="2026-03-26T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="AMOCOTP" b2="138 KV" b3="DUME1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="AMOCOTP" b2="138 KV" b3="LB13_MO" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="AMOCOTP" b2="138 KV" b3="SW_8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="138 KV" b3="7778" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="138 KV" b3="7793" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHEFFILD" b2="138 KV" b3="SHE-AMO1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63870</SeqNum>
    <Name>230/34.Atlantic.T3 + Atlantic.STATCOM</Name>
    <LastEdit Timestamp="2024-08-20T09:04:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="34 KV" b3="2TRDUM" />
      <ContingencyEquipment Action="X" Type="XF" b1="ATLANTIC" b2="230 KV" b3="3TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B54" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B61" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ATLANTIC" b2="230 KV" b3="CAP3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ATLANTIC" b2="230 KV" b3="CAP4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ATLANTIC" b2="230 KV" b3="SVS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63890</SeqNum>
    <Name>L230.Earleys-NHampton-Carolina.2012</Name>
    <LastEdit Timestamp="2025-08-14T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CAROLINA" b2="230 KV" b3="CAR-NHAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAROLINA" b2="230 KV" b3="H4T2012" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="20122014" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="201262" />
      <ContingencyEquipment Action="L" Type="LN" b1="EARLEYS" b2="230 KV" b3="2012A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHAMPTON" b2="230 KV" b3="H152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHAMPTON" b2="230 KV" b3="H252" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NHAMPTON" b2="36.5 KV" b3="LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="NHAMPTON" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NHAMPTON" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63920</SeqNum>
    <Name>115/46.Westfall.T5</Name>
    <LastEdit Timestamp="2025-08-14T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTFALL" b2="115 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTFALL" b2="46 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTFALL" b2="115 KV" b3="B58" />
      <ContingencyEquipment Action="X" Type="XF" b1="WESTFALL" b2="115 KV" b3="BK_5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63930</SeqNum>
    <Name>115/46.Westfall.T3&amp;T4</Name>
    <LastEdit Timestamp="2024-11-21T14:33:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTFALL" b2="115 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTFALL" b2="115 KV" b3="B6 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WESTFALL" b2="115 KV" b3="BK_3" />
      <ContingencyEquipment Action="X" Type="XF" b1="WESTFALL" b2="115 KV" b3="BK_4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTFALL" b2="46 KV" b3="NO_3_TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTFALL" b2="46 KV" b3="NO_4_TX" />
      <ContingencyEquipment Action="S" Type="SD" b1="WESTFALL" b2="46 KV" b3="REACT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63940</SeqNum>
    <Name>345/138.Ramapo.BK2300</Name>
    <LastEdit Timestamp="2025-02-18T13:05:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="1500-2X" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="2500-69" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="138 KV" b3="51-2Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="138 KV" b3="52-2Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="138 KV" b3="60-2Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="76-2X" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="77-2X" />
      <ContingencyEquipment Action="X" Type="XF" b1="RAMAPO" b2="345 KV" b3="BK2300" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="T-70-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63950</SeqNum>
    <Name>345/138.Ramapo.BK1300</Name>
    <LastEdit Timestamp="2025-02-18T13:06:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="138 KV" b3="26-2X" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="69-2Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="70-2Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="76-1Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="94-2Y" />
      <ContingencyEquipment Action="X" Type="XF" b1="RAMAPO" b2="345 KV" b3="BK1300" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="138 KV" b3="FB-2X" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="138 KV" b3="T-X-51-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="W-72-2Y" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63960</SeqNum>
    <Name>230/69.Benning.T11</Name>
    <LastEdit Timestamp="2025-04-10T15:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="P" Type="XF" b1="BENNING" b2="69 KV" b3="11T-PS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENNING" b2="230 KV" b3="230-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="3AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="3BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K6B" />
      <ContingencyEquipment Action="X" Type="XF" b1="BENNING" b2="230 KV" b3="STA-11T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63980</SeqNum>
    <Name>L230.NorthLebanon-Copperstone</Name>
    <LastEdit Timestamp="2025-02-28T12:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COPPERST" b2="230 KV" b3="COP-NLE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="230 KV" b3="NLEB-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="230 KV" b3="NLEB-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEBNON" b2="230 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEBNON" b2="230 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>63990</SeqNum>
    <Name>L138.Cranberry-TRAluminum-EPWorth-BrushCrk-Pine</Name>
    <LastEdit Timestamp="2024-11-13T13:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUSHCRK" b2="138 KV" b3="BRU-PPPI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUSHCRK" b2="138 KV" b3="BRUSHLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRANBERY" b2="138 KV" b3="CRA-TRA" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRUSHCRK" b2="138 KV" b3="BRU-EPWO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EPWORTH" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EPWORTH" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PPPINE" b2="138 KV" b3="A40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PPPINE" b2="138 KV" b3="B38" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPWORTH" b2="138 KV" b3="EPW-TRA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRALUM" b2="138 KV" b3="LDTR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64000</SeqNum>
    <Name>L138.Cranberry-Fernway-BulkMailFacility</Name>
    <LastEdit Timestamp="2024-11-13T13:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BMF" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BMF" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BMF" b2="138 KV" b3="CS60" />
      <ContingencyEquipment Action="L" Type="LN" b1="FERNWY" b2="138 KV" b3="FER-BMF1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BMF" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRANBERY" b2="138 KV" b3="CRA-FER" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FERNWY" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FERNWY" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64010</SeqNum>
    <Name>500/138.Cranberry.T1</Name>
    <LastEdit Timestamp="2024-06-19T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="500 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="500 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRANBERY" b2="500 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64020</SeqNum>
    <Name>500/138.Cranberry.T2</Name>
    <LastEdit Timestamp="2024-06-19T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="500 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANBERY" b2="500 KV" b3="B6" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRANBERY" b2="500 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64120</SeqNum>
    <Name>L138.153Taylor-197Grenshaw.15301 G(SPOG 2-32)</Name>
    <LastEdit Timestamp="2025-07-23T16:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="153 TAYL" b2="138 KV" b3="15301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="197 GREN" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="197 GREN" b2="138 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="197 GREN" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="197 GREN" b2="138 KV" b3="BT4-5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64130</SeqNum>
    <Name>L138.7StateLine-137WashingtonPark.0705 G</Name>
    <LastEdit Timestamp="2025-10-10T12:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="7 STATE" b2="138 KV" b3="0705" />
      <ContingencyEquipment Action="CL" Type="CB" b1="137 WASH" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="137 WASH" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="138 KV" b3="L0705 CB" />
      <ContingencyEquipment Action="P" Type="XF" b1="7 STATE" b2="138 KV" b3="P0705" />
      <ContingencyEquipment Action="X" Type="XF" b1="7 STATE" b2="138 KV" b3="P0705T38" />
      <ContingencyEquipment Action="X" Type="XF" b1="7 STATE" b2="138 KV" b3="Z0705T38" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64140</SeqNum>
    <Name>L138.174University-197Grenshaw.17401 G</Name>
    <LastEdit Timestamp="2025-01-21T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="174 UNIV" b2="138 KV" b3="38L17401" />
      <ContingencyEquipment Action="L" Type="LN" b1="174 UNIV" b2="138 KV" b3="17401" />
      <ContingencyEquipment Action="CL" Type="CB" b1="197 GREN" b2="138 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="197 GREN" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="197 GREN" b2="138 KV" b3="BT4-5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64150</SeqNum>
    <Name>L138.174Univ-137Washington.17404 G (SPOG 2-32)</Name>
    <LastEdit Timestamp="2025-07-24T16:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="137 WASH" b2="138 KV" b3="17404" />
      <ContingencyEquipment Action="OP" Type="CB" b1="137 WASH" b2="138 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="137 WASH" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="137 WASH" b2="138 KV" b3="TR72-X12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="137 WASH" b2="138 KV" b3="TR72-Y12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="174 UNIV" b2="138 KV" b3="L17404" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64160</SeqNum>
    <Name>345/138.101Itasca.T81</Name>
    <LastEdit Timestamp="2024-10-16T09:27:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="345 KV" b3="17-18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="345 KV" b3="18-19" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="101 ITAS" b2="34.5 KV" b3="34C1TR81" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="101 ITAS" b2="34.5 KV" b3="34C2TR81" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="101 ITAS" b2="34.5 KV" b3="34C3TR81" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="101 ITAS" b2="34.5 KV" b3="34C4TR81" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="101 ITAS" b2="34.5 KV" b3="34C5TR81" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="101 ITAS" b2="34.5 KV" b3="34C6TR81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="101 ITAS" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="101 ITAS" b2="138 KV" b3="TR81CT-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="101 ITAS" b2="34.5 KV" b3="TR81CT-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64170</SeqNum>
    <Name>345/138.101Itasca.T82</Name>
    <LastEdit Timestamp="2025-02-18T11:43:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="X" Type="XF" b1="101 ITAS" b2="345 KV" b3="TR82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="TR82 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64180</SeqNum>
    <Name>345/138.SouthCanton.T4</Name>
    <LastEdit Timestamp="2024-06-19T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SCANTON2" b2="345 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="M1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="345 KV" b3="XT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64350</SeqNum>
    <Name>L230.Benning-Ritchie.23004</Name>
    <LastEdit Timestamp="2024-06-19T14:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="1BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="1CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENNING" b2="230 KV" b3="BEN-RIT4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="230 KV" b3="23004B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64370</SeqNum>
    <Name>230/115.WaughChapel.T4</Name>
    <LastEdit Timestamp="2025-06-06T12:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="110539SF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="110544SF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="14TIE" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAUGHCHA" b2="230 KV" b3="230-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="23041BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="23044BUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64380</SeqNum>
    <Name>Seneca.U1</Name>
    <LastEdit Timestamp="2024-06-19T15:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="SENECA" b2="13 KV" b3="1GEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SENECA" b2="230 KV" b3="NO1 GEN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64390</SeqNum>
    <Name>Seneca.U2</Name>
    <LastEdit Timestamp="2024-06-19T15:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="SENECA" b2="13 KV" b3="2GEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SENECA" b2="230 KV" b3="NO2 GEN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64400</SeqNum>
    <Name>Seneca.U3</Name>
    <LastEdit Timestamp="2024-06-24T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="SENECA" b2="13 KV" b3="3GEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SENECA" b2="230 KV" b3="3GEN230" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64430</SeqNum>
    <Name>345/138.SilverLake.T82 G SPOG 2-38</Name>
    <LastEdit Timestamp="2026-05-06T10:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="138 SILV" b2="345 KV" b3="TR82CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="138 SILV" b2="345 KV" b3="TR82CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="138 SILV" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64440</SeqNum>
    <Name>345/138.SilverLake.T83 G SPOG 2-38</Name>
    <LastEdit Timestamp="2026-05-06T10:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="138 SILV" b2="345 KV" b3="TR83 CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="138 SILV" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="138 SILV" b2="138 KV" b3="TR83CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64450</SeqNum>
    <Name>138.Silver Lk-13808-Crystal Lk.13808 G (SPOG 2-38)</Name>
    <LastEdit Timestamp="2025-09-05T11:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="138 SILV" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="138 KV" b3="L13808CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="138 SILV" b2="138 KV" b3="13808 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="13808" b2="138 KV" b3="13808 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="75 CRYST" b2="138 KV" b3="13808 Z1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="193 MCHE" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="193 MCHE" b2="138 KV" b3="L13808CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="75 CRYST" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="75 CRYST" b2="138 KV" b3="DUM02697" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64460</SeqNum>
    <Name>138.Silver Lk-13809-Crystal Lk.13809 G (SPOG 2-38)</Name>
    <LastEdit Timestamp="2024-12-12T11:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="138 SILV" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="138 KV" b3="L13809CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="138 SILV" b2="138 KV" b3="13809 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="193 MCHE" b2="138 KV" b3="13809 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="13809" b2="138 KV" b3="13809 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="13809" b2="138 KV" b3="13809 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="75 CRYST" b2="138 KV" b3="13809 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="141 PLEA" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="193 MCHE" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="193 MCHE" b2="138 KV" b3="L13809CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="75 CRYST" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="75 CRYST" b2="138 KV" b3="L13809CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64470</SeqNum>
    <Name>230/115.PossumPoint.T8</Name>
    <LastEdit Timestamp="2024-06-19T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="H892" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="230 KV" b3="H8T2078" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="115 KV" b3="L892" />
      <ContingencyEquipment Action="X" Type="XF" b1="POSSUMP4" b2="230 KV" b3="TX8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64510</SeqNum>
    <Name>VirginiaCity.U1</Name>
    <LastEdit Timestamp="2025-07-29T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VIRGINIA" b2="138 KV" b3="G1TL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIRGINIA" b2="138 KV" b3="G1TL2" />
      <ContingencyEquipment Action="X" Type="XF" b1="VIRGINIA" b2="138 KV" b3="LOADXFMR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VIRGINIA" b2="13 KV" b3="SSLOAD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="VIRGINIA" b2="25 KV" b3="VACTYG1" />
      <ContingencyEquipment Action="X" Type="XF" b1="VIRGINIA" b2="138 KV" b3="VACTYGSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64530</SeqNum>
    <Name>L138.IndianRiver-Bishop.13720</Name>
    <LastEdit Timestamp="2024-06-19T14:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP" b2="138 KV" b3="161" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP" b2="138 KV" b3="162" />
      <ContingencyEquipment Action="L" Type="LN" b1="BISHOP" b2="138 KV" b3="BIS-IND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="136" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64580</SeqNum>
    <Name>230/115.Fredericksburg.TX8</Name>
    <LastEdit Timestamp="2024-06-19T14:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRDRKSBG" b2="230 KV" b3="H842" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRDRKSBG" b2="115 KV" b3="L842" />
      <ContingencyEquipment Action="X" Type="XF" b1="FRDRKSBG" b2="230 KV" b3="TX8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64590</SeqNum>
    <Name>L115.Dooms-DupontWaynesboro.146A</Name>
    <LastEdit Timestamp="2024-06-19T14:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="115 KV" b3="14642" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOOMS4" b2="115 KV" b3="146A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPWAYNE" b2="115 KV" b3="14652" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64910</SeqNum>
    <Name>138/69.Bethel.T3</Name>
    <LastEdit Timestamp="2024-06-19T14:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHEL2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHEL2" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHEL2" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64920</SeqNum>
    <Name>L138.Springdale-ShaffersCorner</Name>
    <LastEdit Timestamp="2025-12-29T10:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHAFFERS" b2="138 KV" b3="SPRINGDA" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHAFFERS" b2="138 KV" b3="SHA-SPR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="SHAFFERS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>64930</SeqNum>
    <Name>L345.Salem-RockCreek(MEC)</Name>
    <LastEdit Timestamp="2024-06-19T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCK CRE" b2="345 KV" b3="181" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCK CRE" b2="345 KV" b3="182" />
      <ContingencyEquipment Action="L" Type="LN" b1="SALEM  6" b2="345 KV" b3="62073620" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM  6" b2="345 KV" b3="215_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM  6" b2="345 KV" b3="2870" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65000</SeqNum>
    <Name>L345.GaryAve-Sheffield (NIPS)</Name>
    <LastEdit Timestamp="2025-03-28T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GARYAVE" b2="345 KV" b3="34520_BR" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARYAVE" b2="345 KV" b3="GAR-SHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="345 KV" b3="1120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="345 KV" b3="2000" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65030</SeqNum>
    <Name>L345.Monroe-Brownstown (DET)</Name>
    <LastEdit Timestamp="2024-06-19T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROWNSTO" b2="345 KV" b3="BRO-MON1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWNSTO" b2="345 KV" b3="EM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWNSTO" b2="345 KV" b3="ET" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONROE" b2="345 KV" b3="BF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONROE" b2="345 KV" b3="BM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65040</SeqNum>
    <Name>345/138.Collier.T3</Name>
    <LastEdit Timestamp="2024-06-19T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="138 KV" b3="BUSTIE13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="138 KV" b3="BUSTIE32" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLLIER" b2="345 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="T3-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLIER" b2="345 KV" b3="T3-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65060</SeqNum>
    <Name>230/69.Harwood.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T14:47:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HARWOOD" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="230 KV" b3="CAP2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="69 KV" b3="TRAN4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARWOOD" b2="230 KV" b3="TRAN4MOD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65080</SeqNum>
    <Name>230/69.Harwood.T5 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T14:48:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HARWOOD" b2="230 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARWOOD" b2="230 KV" b3="TRAN5MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="69 KV" b3="TRAN_5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65120</SeqNum>
    <Name>L230.Hopewell-PrGeorge.2124 + 230/115.PrGeorge.T1</Name>
    <LastEdit Timestamp="2025-03-28T15:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="211T2124" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPEWEL4" b2="230 KV" b3="2124" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="212432" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRGEORGE" b2="230 KV" b3="H122" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PRGEORGE" b2="230 KV" b3="LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="PRGEORGE" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65130</SeqNum>
    <Name>230/115.Pr.George.T1</Name>
    <LastEdit Timestamp="2025-06-06T17:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PRGEORGE" b2="230 KV" b3="H122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRGEORGE" b2="115 KV" b3="L1T121" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRGEORGE" b2="115 KV" b3="L1T97" />
      <ContingencyEquipment Action="X" Type="XF" b1="PRGEORGE" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65140</SeqNum>
    <Name>L115.Poe-PrinceGeorge.121</Name>
    <LastEdit Timestamp="2024-06-19T14:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POE" b2="115 KV" b3="12152" />
      <ContingencyEquipment Action="L" Type="LN" b1="POE" b2="115 KV" b3="121A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRGEORGE" b2="115 KV" b3="97T121" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRGEORGE" b2="115 KV" b3="L1T121" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65160</SeqNum>
    <Name>L230.Moshannon-Chapman-Lobo-Marshall</Name>
    <LastEdit Timestamp="2024-06-19T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHAPMAN" b2="230 KV" b3="CHH-LOB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAPMAN" b2="230 KV" b3="CHH-MOS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOBO" b2="230 KV" b3="1TX" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOBO" b2="230 KV" b3="LOB-MARS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHALL" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHALL" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSHANON" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSHANON" b2="230 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65240</SeqNum>
    <Name>CalvertCliffs.P-13000-2.SS </Name>
    <LastEdit Timestamp="2025-04-24T14:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="51" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CALVERTC" b2="500 KV" b3="LDR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65250</SeqNum>
    <Name>CalvertCliffs.P-13000-1.SS</Name>
    <LastEdit Timestamp="2025-04-23T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="31" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65270</SeqNum>
    <Name>L230.Branchburg-Sunnymeade.W-2302</Name>
    <LastEdit Timestamp="2024-10-02T14:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRANCHBU" b2="230 KV" b3="BRA-SUN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNNYMEA" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENNETTS" b2="230 KV" b3="BEN-SUN5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUNNYMEA" b2="230 KV" b3="T12TRANS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SUNNYMEA" b2="230 KV" b3="T34TRANS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUNNYMEA" b2="230 KV" b3="TRANT-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUNNYMEA" b2="230 KV" b3="TRANT-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65320</SeqNum>
    <Name>L138.Beatty-Bolton</Name>
    <LastEdit Timestamp="2024-06-19T14:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="3C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="3W" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEATTY" b2="138 KV" b3="BEA-BOL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOLTON" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOLTON" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65330</SeqNum>
    <Name>L345.12Dresden-939Mulberry.1202</Name>
    <LastEdit Timestamp="2025-10-15T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT4-8 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="345 KV" b3="DRE-MUL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="939_MUL" b2="345 KV" b3="7-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="939_MUL" b2="345 KV" b3="8-11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65340</SeqNum>
    <Name>Covert.GTG1 &amp; STG1</Name>
    <LastEdit Timestamp="2024-06-19T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="345 KV" b3="1020" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="345 KV" b3="199" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COVERT" b2="16 KV" b3="1GTG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="16 KV" b3="1GTG CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COVERT" b2="16 KV" b3="1STG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="16 KV" b3="1STG CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="345 KV" b3="6010" />
      <ContingencyEquipment Action="X" Type="XF" b1="COVERT" b2="345 KV" b3="TB1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65350</SeqNum>
    <Name>138/69.Academia.T1</Name>
    <LastEdit Timestamp="2024-06-19T14:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ACADEMIA" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ACADEMIA" b2="12 KV" b3="12KV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ACADEMIA" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ACADEMIA" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65360</SeqNum>
    <Name>230/35.Planebrook.T1+Bus#7</Name>
    <LastEdit Timestamp="2024-06-24T09:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="35 KV" b3="10 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="245 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="25CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="785 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADFORD" b2="230 KV" b3="BRA-PLA2" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLANEBRO" b2="230 KV" b3="PLA 1TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLANEBRO" b2="230 KV" b3="PLA-TRE4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65370</SeqNum>
    <Name>L138.Ashland-Whittier</Name>
    <LastEdit Timestamp="2024-06-24T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08ASHLD7" b2="138 KV" b3="868" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08ASHLD7" b2="138 KV" b3="870" />
      <ContingencyEquipment Action="L" Type="LN" b1="08ASHLD7" b2="138 KV" b3="ASH-WHIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITTIER" b2="138 KV" b3="982" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITTIER" b2="138 KV" b3="988" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65540</SeqNum>
    <Name>230/69.Jenkins.T1</Name>
    <LastEdit Timestamp="2024-06-21T12:51:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="JENKINS" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="230 KV" b3="MOUNWEST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="230 KV" b3="STAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="230 KV" b3="TRAN2W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65620</SeqNum>
    <Name>L345.Lanesville-MtPulaski.2107</Name>
    <LastEdit Timestamp="2024-10-23T13:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="188 MTPU" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="188 MTPU" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="188 MTPU" b2="345 KV" b3="2107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANESVL" b2="345 KV" b3="BT3587CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANESVL" b2="345 KV" b3="BT3588CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65630</SeqNum>
    <Name>L345.Brokaw-McLean.9203</Name>
    <LastEdit Timestamp="2025-05-02T12:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="92 MCLEA" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="92 MCLEA" b2="345 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="345 KV" b3="4546" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="345 KV" b3="4550" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROKAW" b2="345 KV" b3="9203" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65640</SeqNum>
    <Name>L500.FrontRoyal-Morrisville.541</Name>
    <LastEdit Timestamp="2024-06-24T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FRONTROY" b2="500 KV" b3="541A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTROY" b2="500 KV" b3="541T580" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTROY" b2="500 KV" b3="541T592" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="500 KV" b3="541T569" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISVL" b2="500 KV" b3="H1T541" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65720</SeqNum>
    <Name>L230.Landstown-Birdneck-VirginaBeach.2118</Name>
    <LastEdit Timestamp="2025-09-23T16:46:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BIRDNECK" b2="230 KV" b3="2118B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIRDNECK" b2="230 KV" b3="H102" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BIRDNECK" b2="34.5 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BIRDNECK" b2="230 KV" b3="TX_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="230 KV" b3="20852118" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="230 KV" b3="211852" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIRDNECK" b2="230 KV" b3="2118A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="230 KV" b3="H5T22118" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="230 KV" b3="H6T2118" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65740</SeqNum>
    <Name>230/115.VirginiaBeach.TX5</Name>
    <LastEdit Timestamp="2024-10-09T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="230 KV" b3="H572" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="115 KV" b3="L572" />
      <ContingencyEquipment Action="X" Type="XF" b1="VABEACH" b2="230 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65750</SeqNum>
    <Name>230/115.VirginiaBeach.TX6</Name>
    <LastEdit Timestamp="2024-10-09T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="230 KV" b3="H672" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="115 KV" b3="L672" />
      <ContingencyEquipment Action="X" Type="XF" b1="VABEACH" b2="230 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65760</SeqNum>
    <Name>115/35.VirginiaBeach.TX1 </Name>
    <LastEdit Timestamp="2026-04-27T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="115 KV" b3="H172" />
      <ContingencyEquipment Action="X" Type="XF" b1="VABEACH" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VABEACH" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65770</SeqNum>
    <Name>115/35.VirginiaBeach.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-11T15:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="VABEACH" b2="115 KV" b3="H274M" />
      <ContingencyEquipment Action="X" Type="XF" b1="VABEACH" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VABEACH" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65800</SeqNum>
    <Name>L230.Graceton-Bagley-RaphaelRoad.2305</Name>
    <LastEdit Timestamp="2025-01-15T18:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAGLEY" b2="230 KV" b3="2305GCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAGLEY" b2="230 KV" b3="BAG-GRA" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAGLEY" b2="230 KV" b3="BAG-RAP5" />
      <ContingencyEquipment Action="CL" Type="CB" b1="BAGLEY" b2="230 KV" b3="TIECB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRACETON" b2="230 KV" b3="2305-1TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRACETON" b2="230 KV" b3="2305CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPHAERD" b2="230 KV" b3="2305" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPHAERD" b2="230 KV" b3="2305_15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65820</SeqNum>
    <Name>L230.Nottingham-Clay.220-98</Name>
    <LastEdit Timestamp="2025-04-02T15:22:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAY PE" b2="230 KV" b3="715" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAY PE" b2="230 KV" b3="785" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAY PE" b2="230 KV" b3="CLA-NOT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTTINGH" b2="230 KV" b3="985" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65830</SeqNum>
    <Name>L138.Greenwood-MillbrookTap-Redbud (APS)</Name>
    <LastEdit Timestamp="2025-11-17T15:38:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENWOO" b2="138 KV" b3="1338" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENWOO" b2="138 KV" b3="GRE-MILL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILLBR_T" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBUD" b2="138 KV" b3="GREENWOO" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLBR_T" b2="138 KV" b3="MIL-REDB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65840</SeqNum>
    <Name>230/115.KittyHawk.TX7</Name>
    <LastEdit Timestamp="2024-06-24T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="230 KV" b3="H752" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="115 KV" b3="L752" />
      <ContingencyEquipment Action="X" Type="XF" b1="KITTYHWK" b2="230 KV" b3="TX7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65850</SeqNum>
    <Name>L115.Mehoopany-MountainTop</Name>
    <LastEdit Timestamp="2024-06-24T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEHOOPAN" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEHOOPAN" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEHOOPAN" b2="115 KV" b3="MEH-MOUT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTNTOP" b2="115 KV" b3="52-1-T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65880</SeqNum>
    <Name>230/115.Hayes.TX3</Name>
    <LastEdit Timestamp="2024-06-24T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GAINESPT" b2="230 KV" b3="GAI-HAYE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES" b2="230 KV" b3="H342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES" b2="115 KV" b3="L342" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAYES" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65890</SeqNum>
    <Name>L230.YorkTown-YorkTownTerminal-GainesPt-Hayes.2122</Name>
    <LastEdit Timestamp="2025-01-31T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GAINESPT" b2="230 KV" b3="GAI-HAYE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES" b2="230 KV" b3="H342" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAYES" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="230 KV" b3="212282" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="230 KV" b3="288T2122" />
      <ContingencyEquipment Action="L" Type="LN" b1="YORKTOW4" b2="230 KV" b3="YOR-YRKT" />
      <ContingencyEquipment Action="L" Type="LN" b1="GAINESPT" b2="230 KV" b3="GAI-YOR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GAINESPT" b2="230 KV" b3="GAI-YOR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>65900</SeqNum>
    <Name>230/138.Cecil.AT20</Name>
    <LastEdit Timestamp="2024-06-24T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CECIL" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CECIL" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CECIL" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CECIL" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="X" Type="XF" b1="CECIL" b2="230 KV" b3="AT20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66020</SeqNum>
    <Name>L230.Burke-Centerville-Bullrun.244 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-11-21T12:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BULLRUN" b2="230 KV" b3="24466M" />
      <ContingencyEquipment Action="L" Type="LN" b1="BULLRUN" b2="230 KV" b3="244A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURKE" b2="230 KV" b3="244T270" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURKE" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BURKE" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CNTRVLIN" b2="230 KV" b3="244B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CNTRVLIN" b2="4 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CNTRVLIN" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CNTRVLIN" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CNTRVLIN" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CNTRVLIN" b2="35 KV" b3="TX3LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="CNTRVLIN" b2="230 KV" b3="TX_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66030</SeqNum>
    <Name>L230.Loudoun-ElkLickDp.2173</Name>
    <LastEdit Timestamp="2024-06-24T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELKLCKDP" b2="230 KV" b3="217372-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELKLCKDP" b2="230 KV" b3="217372-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="21232173" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="217352" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKLCKDP" b2="230 KV" b3="2173A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66040</SeqNum>
    <Name>L230.Carson-ClubHouse.238 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="230 KV" b3="23872" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARSON4" b2="230 KV" b3="238A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="230 KV" b3="238T2002" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLBHOUSE" b2="230 KV" b3="23856M" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAPONY" b2="230 KV" b3="238B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAPONY" b2="35 KV" b3="33282" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SAPONY" b2="35 KV" b3="SAPONYSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="SAPONY" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SAPONY" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66050</SeqNum>
    <Name>500/230.Carson.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-03-20T12:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CARSON4" b2="500 KV" b3="H274M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="230 KV" b3="L272" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARSON4" b2="500 KV" b3="TX2H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66060</SeqNum>
    <Name>L230.Carson-Poe.2002 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-05-15T12:58:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="230 KV" b3="200272" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="230 KV" b3="238T2002" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POE" b2="230 KV" b3="200259M" />
      <ContingencyEquipment Action="L" Type="LN" b1="POE" b2="230 KV" b3="2002A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66070</SeqNum>
    <Name>L230.Chesterfield-Poe.2003 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-06-24T11:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="200312" />
      <ContingencyEquipment Action="L" Type="LN" b1="TYLER" b2="230 KV" b3="2003A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="230 KV" b3="259T2003" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POE" b2="230 KV" b3="200359M" />
      <ContingencyEquipment Action="L" Type="LN" b1="TYLER" b2="230 KV" b3="2003B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYLER" b2="230 KV" b3="H192" />
      <ContingencyEquipment Action="X" Type="XF" b1="TYLER" b2="230 KV" b3="TX1_" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66080</SeqNum>
    <Name>500/230.Dooms.TX9 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-05-12T14:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="DOOMS4" b2="500 KV" b3="H944M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="L942" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOOMS4" b2="500 KV" b3="TX9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66090</SeqNum>
    <Name>L230.Gordonsville-CashCorn-Hollymead.2135</Name>
    <LastEdit Timestamp="2025-12-18T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CASHCNDP" b2="230 KV" b3="H172" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CASHCNDP" b2="115 KV" b3="LD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CASHCNDP" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONSV" b2="230 KV" b3="21352199" />
      <ContingencyEquipment Action="L" Type="LN" b1="CASHCNDP" b2="230 KV" b3="2135A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONSV" b2="230 KV" b3="H1T2135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLYMD" b2="230 KV" b3="20542135" />
      <ContingencyEquipment Action="L" Type="LN" b1="CASHCNDP" b2="230 KV" b3="2135B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLYMD" b2="230 KV" b3="H142" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOLLYMD" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOLLYMD" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66100</SeqNum>
    <Name>L230.Gordonsville-LouisaCT.2088</Name>
    <LastEdit Timestamp="2025-03-24T11:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GORDONSV" b2="230 KV" b3="2088A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONSV" b2="230 KV" b3="H1T2088" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONSV" b2="230 KV" b3="YT2088" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISACT" b2="230 KV" b3="G34T2088" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISACT" b2="230 KV" b3="G5T2088" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66110</SeqNum>
    <Name>L230.Dooms-Grottoes.272 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-01-06T16:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="27242" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="272T291" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="115 KV" b3="L842-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="115 KV" b3="L842-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOOMS4" b2="230 KV" b3="TX8" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GROTTOES" b2="230 KV" b3="27289M" />
      <ContingencyEquipment Action="L" Type="LN" b1="GROTTOES" b2="230 KV" b3="272A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66140</SeqNum>
    <Name>L230.Lanexa-Lightfoot-Waller.2113</Name>
    <LastEdit Timestamp="2025-12-01T13:47:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="230 KV" b3="211332" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="230 KV" b3="224T2113" />
      <ContingencyEquipment Action="L" Type="LN" b1="LGHTFOOT" b2="230 KV" b3="2113A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LGHTFOOT" b2="230 KV" b3="H112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALLER" b2="230 KV" b3="21132154" />
      <ContingencyEquipment Action="L" Type="LN" b1="WALLER" b2="230 KV" b3="2113B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALLER" b2="230 KV" b3="H342" />
      <ContingencyEquipment Action="X" Type="XF" b1="WALLER" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALLER" b2="35 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66150</SeqNum>
    <Name>L230.Peninsula-Tabb-Yorktown.288 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-17T08:30:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="PENINSLA" b2="230 KV" b3="28809M" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENINSLA" b2="230 KV" b3="288A" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="TABB" b2="35 KV" b3="CAP1" />
      <ContingencyEquipment Action="X" Type="XF" b1="TABB" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TABB" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="TABB" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TABB" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="230 KV" b3="28882" />
      <ContingencyEquipment Action="L" Type="LN" b1="YORKTOW4" b2="230 KV" b3="288B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="230 KV" b3="288T2122" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66180</SeqNum>
    <Name>500/230.Suffolk.T8 (Sectionalize)</Name>
    <LastEdit Timestamp="2024-06-24T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUFFOLK" b2="500 KV" b3="H844M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="230 KV" b3="L842" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUFFOLK" b2="500 KV" b3="TX8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66220</SeqNum>
    <Name>L345.Oakdale-Watercure</Name>
    <LastEdit Timestamp="2026-01-16T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKDALE" b2="345 KV" b3="31-B322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKDALE" b2="345 KV" b3="36-3122" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKDALE" b2="345 KV" b3="OAK-WAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERCUR" b2="345 KV" b3="31-B242" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERCUR" b2="345 KV" b3="3142" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66230</SeqNum>
    <Name>L345.Oakdale-Fraser</Name>
    <LastEdit Timestamp="2024-11-04T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRASER" b2="345 KV" b3="32-3362" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRASER" b2="345 KV" b3="B1-3262" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRASER" b2="345 KV" b3="FRA-OAK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKDALE" b2="345 KV" b3="32-B222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKDALE" b2="345 KV" b3="B3-3222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKDALE" b2="345 KV" b3="C122" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="OAKDALE" b2="345 KV" b3="CAP 01" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66240</SeqNum>
    <Name>L500.McGuire-Antioch</Name>
    <LastEdit Timestamp="2025-06-04T14:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ANTIOCH4" b2="500 KV" b3="11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANTIOCH4" b2="500 KV" b3="21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCGUIRE4" b2="500 KV" b3="55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCGUIRE4" b2="500 KV" b3="56" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MCGUIRE4" b2="500 KV" b3="JFER" />
      <ContingencyEquipment Action="S" Type="SD" b1="MCGUIRE4" b2="500 KV" b3="RCKSPR_1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANTIOCH4" b2="500 KV" b3="ROCKSPRI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66250</SeqNum>
    <Name>L345.WestGarrard-Pineville</Name>
    <LastEdit Timestamp="2024-06-24T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEVIL" b2="345 KV" b3="B192_952" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEVIL" b2="345 KV" b3="CB954" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_GARARD" b2="345 KV" b3="CB912" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_GARARD" b2="345 KV" b3="CB914" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINEVIL" b2="345 KV" b3="PIN-WGAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66260</SeqNum>
    <Name>L345.NBrown-Alcalde-Pinevlle+345/161.Alcalde.XF146</Name>
    <LastEdit Timestamp="2025-11-04T16:53:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALCALDE" b2="161 KV" b3="B194_808" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALCALDE" b2="345 KV" b3="XF146" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCALDE" b2="345 KV" b3="ALC-BROW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_NO" b2="345 KV" b3="B152_924" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_NO" b2="345 KV" b3="B152_932" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEVIL" b2="345 KV" b3="B192_932" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEVIL" b2="345 KV" b3="CB954" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCALDE" b2="345 KV" b3="PIN-ALCA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66270</SeqNum>
    <Name>McGuire.U5002</Name>
    <LastEdit Timestamp="2024-06-24T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MCGUIRE4" b2="24 KV" b3="5002" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCGUIRE4" b2="24 KV" b3="GCB2A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCGUIRE4" b2="24 KV" b3="GCB2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66280</SeqNum>
    <Name>Belews.U2301</Name>
    <LastEdit Timestamp="2024-06-24T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="BELEWS" b2="18 KV" b3="2301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELEWS" b2="18 KV" b3="GCB1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66290</SeqNum>
    <Name>Belews.U2302</Name>
    <LastEdit Timestamp="2026-01-21T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELEWS" b2="230 KV" b3="11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELEWS" b2="230 KV" b3="12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELEWS" b2="230 KV" b3="14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELEWS" b2="230 KV" b3="15" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BELEWS" b2="18 KV" b3="2302" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELEWS" b2="230 KV" b3="BK2A" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELEWS" b2="230 KV" b3="BK2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66300</SeqNum>
    <Name>Marshal.U2303</Name>
    <LastEdit Timestamp="2024-06-24T11:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MARSHAL4" b2="24 KV" b3="2303" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHAL4" b2="24 KV" b3="GCB3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66310</SeqNum>
    <Name>Marshal.U2304</Name>
    <LastEdit Timestamp="2024-06-24T11:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MARSHAL4" b2="24 KV" b3="2304" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHAL4" b2="24 KV" b3="GCB4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66320</SeqNum>
    <Name>McGuire.U2301</Name>
    <LastEdit Timestamp="2024-06-24T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MCGUIRE4" b2="24 KV" b3="2301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCGUIRE4" b2="24 KV" b3="GCB1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCGUIRE4" b2="24 KV" b3="GCB1B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66330</SeqNum>
    <Name>Cliffside.U1</Name>
    <LastEdit Timestamp="2025-03-17T13:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLIFFSID" b2="24 KV" b3="GEN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFFSID" b2="24 KV" b3="UN_6CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66340</SeqNum>
    <Name>Cliffside.U2305</Name>
    <LastEdit Timestamp="2024-06-24T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFSID" b2="230 KV" b3="20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFSID" b2="230 KV" b3="21" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLIFSID" b2="24 KV" b3="2305" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66350</SeqNum>
    <Name>Catawba.U2301</Name>
    <LastEdit Timestamp="2024-06-24T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CATAWBA4" b2="22 KV" b3="2301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CATAWBA4" b2="22 KV" b3="GCB1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CATAWBA4" b2="22 KV" b3="GCB1B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66360</SeqNum>
    <Name>Catawba.U2302</Name>
    <LastEdit Timestamp="2024-06-24T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CATAWBA4" b2="22 KV" b3="2302" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CATAWBA4" b2="22 KV" b3="GCB2A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CATAWBA4" b2="22 KV" b3="GCB2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66370</SeqNum>
    <Name>500/138.Elroy.T3 &amp; 138/69.Elroy.T4</Name>
    <LastEdit Timestamp="2024-06-24T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ELROYPL" b2="500 KV" b3="3 TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELROYPL" b2="138 KV" b3="4 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROYPL" b2="69 KV" b3="TRAN 4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROYPL" b2="500 KV" b3="TRAN3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66380</SeqNum>
    <Name>230/69.Lawrence.220-3</Name>
    <LastEdit Timestamp="2025-05-13T11:11:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="69 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="220-3CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAWRENCE" b2="230 KV" b3="3TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="69 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66390</SeqNum>
    <Name>L138.NorthBristol-WolfHills</Name>
    <LastEdit Timestamp="2026-03-02T17:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NBRISTOL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFHILL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="NBRISTOL" b2="138 KV" b3="NBR-WOL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66400</SeqNum>
    <Name>230/26.Lawrence.220-2</Name>
    <LastEdit Timestamp="2024-12-17T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="2-4 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAWRENCE" b2="230 KV" b3="220-2 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="220-2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="26 KV" b3="BUSDUMMY" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LAWRENCE" b2="26 KV" b3="CAP2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAWRENCE" b2="26 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66410</SeqNum>
    <Name>230/69.Lawrence.220-4</Name>
    <LastEdit Timestamp="2024-12-12T14:16:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="2-10 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="69 KV" b3="2-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAWRENCE" b2="230 KV" b3="220-4 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="69 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="9-10 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66420</SeqNum>
    <Name>L345.St Francis-Lutesville</Name>
    <LastEdit Timestamp="2024-06-24T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LUTESVI3" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUTESVI3" b2="345 KV" b3="V7" />
      <ContingencyEquipment Action="L" Type="LN" b1="STFRANCS" b2="345 KV" b3="30974317" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STFRANCS" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STFRANCS" b2="345 KV" b3="V13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66530</SeqNum>
    <Name>L115.KitKat-StuartsDraftDP-DupontWayne.117</Name>
    <LastEdit Timestamp="2024-11-20T13:32:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPWAYNE" b2="115 KV" b3="106352" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITKAT" b2="115 KV" b3="117T1063" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KITKAT" b2="115 KV" b3="DP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KITKAT" b2="115 KV" b3="KIT-SDRA" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUPWAYNE" b2="115 KV" b3="DUP-SDRA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SDRAFTDP" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66540</SeqNum>
    <Name>500/230.Clover.T8</Name>
    <LastEdit Timestamp="2024-06-24T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="500 KV" b3="H8T556" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="L812 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVER" b2="500 KV" b3="TX8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66560</SeqNum>
    <Name>L345.Coffeen-Ramsey (Ameren)</Name>
    <LastEdit Timestamp="2024-11-18T13:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COFFEN 3" b2="345 KV" b3="30386315" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COFFEN 3" b2="345 KV" b3="3541" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COFFEN 3" b2="345 KV" b3="3542" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMSEY 3" b2="345 KV" b3="V21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMSEY 3" b2="345 KV" b3="V25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66580</SeqNum>
    <Name>L230.Pentagon-RadnorHts.2121 + 230/69.Pntgn.TX1</Name>
    <LastEdit Timestamp="2024-06-24T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PENTAGON" b2="230 KV" b3="2121A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="230 KV" b3="H122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="69 KV" b3="L122" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENTAGON" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RADNORHT" b2="230 KV" b3="212142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RADNORHT" b2="230 KV" b3="XT2121" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66590</SeqNum>
    <Name>115/69.Face Rock.1&amp;2</Name>
    <LastEdit Timestamp="2024-06-24T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FACEROCK" b2="115 KV" b3="1" />
      <ContingencyEquipment Action="X" Type="XF" b1="FACEROCK" b2="115 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="FIFO695T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="FIFOSBUS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FACEROCK" b2="115 KV" b3="FIFO_1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FACEROCK" b2="115 KV" b3="FIFO_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66600</SeqNum>
    <Name>L69.Lagrange-N.LagrangeTap-Howe (NIPSCO)</Name>
    <LastEdit Timestamp="2024-11-20T16:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HOWE" b2="69 KV" b3="166 DIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOWE" b2="69 KV" b3="HOW-NLA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAGRANGE" b2="69 KV" b3="87" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAGRANGE" b2="69 KV" b3="LAG-NLA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="N_LAGR_T" b2="69 KV" b3="NLAG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66650</SeqNum>
    <Name>345/230.Cayuga.TX10</Name>
    <LastEdit Timestamp="2024-06-24T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CAYUGA2" b2="345 KV" b3="10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="345 KV" b3="10-01" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="230 KV" b3="23003-B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="230 KV" b3="230B10-G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="345 KV" b3="34535-B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66720</SeqNum>
    <Name>L138.Roxana-Bethany.13739</Name>
    <LastEdit Timestamp="2024-06-25T11:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHANY" b2="138 KV" b3="BET-ROXA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXANA" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXANA" b2="138 KV" b3="132" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66950</SeqNum>
    <Name>L138.Avon-Beck-Boonst-Dale-Boonesboro</Name>
    <LastEdit Timestamp="2024-11-14T15:24:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="4BCKNRVT" b2="138 KV" b3="908" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="4BCKNRVT" b2="138 KV" b3="BECKNRVL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVON_EK" b2="138 KV" b3="834" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVON_EK" b2="138 KV" b3="90T" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVON_EK" b2="138 KV" b3="AVO-4BCK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONESBO" b2="138 KV" b3="B213_703" />
      <ContingencyEquipment Action="L" Type="LN" b1="4BCKNRVT" b2="138 KV" b3="4BC-BOON" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOONESBO" b2="138 KV" b3="BO1-BOON" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOONST" b2="138 KV" b3="BOO-DALE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DALESTN" b2="138 KV" b3="CB_814" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DALESTN" b2="138 KV" b3="SW_817" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66960</SeqNum>
    <Name>L138.Avon-Fayette.255 + 138/69.Fayette.T1</Name>
    <LastEdit Timestamp="2024-10-16T13:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AVON_EK" b2="138 KV" b3="874" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVON_EK" b2="138 KV" b3="92T" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVON_EK" b2="138 KV" b3="AVO-FYET" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FYETT_EK" b2="69 KV" b3="CB608" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66980</SeqNum>
    <Name>345/138.Avon.T157</Name>
    <LastEdit Timestamp="2024-10-25T13:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AVON_EK" b2="138 KV" b3="808" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVON_EK" b2="138 KV" b3="818" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVON_EK" b2="345 KV" b3="CB1408" />
      <ContingencyEquipment Action="X" Type="XF" b1="AVON_EK" b2="345 KV" b3="XF157" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>66990</SeqNum>
    <Name>L161.BullittCounty-CedarGrove-BlueLck (Tie)</Name>
    <LastEdit Timestamp="2025-02-18T16:12:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUE_LCK" b2="161 KV" b3="BBL_5402" />
      <ContingencyEquipment Action="L" Type="LN" b1="BULLITCO" b2="161 KV" b3="BUL-CEDL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLITCO" b2="161 KV" b3="CB1014" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BULLITCO" b2="161 KV" b3="SW1017" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR_IT" b2="161 KV" b3="CB1108" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR_IT" b2="161 KV" b3="CB1118" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDAR_IT" b2="161 KV" b3="CED-CEDL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CEDAR_IT" b2="161 KV" b3="LOAD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CEDAR_IT" b2="161 KV" b3="LOAD2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUE_LCK" b2="161 KV" b3="BLU-CEDL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67000</SeqNum>
    <Name>L138.BooneCounty-Sterling-Gallatin</Name>
    <LastEdit Timestamp="2024-06-25T13:51:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOONECO" b2="138 KV" b3="BOO-STRL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONECO" b2="138 KV" b3="CB824" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BOONECO" b2="138 KV" b3="SW827" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALLATIN" b2="138 KV" b3="CB814" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALLATIN" b2="138 KV" b3="CB834" />
      <ContingencyEquipment Action="L" Type="LN" b1="GALLATIN" b2="138 KV" b3="GAL-STRL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STRLG_EK" b2="138 KV" b3="LD_152" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67010</SeqNum>
    <Name>L138.BooneCounty-Bavarian-Renaker</Name>
    <LastEdit Timestamp="2024-06-25T13:50:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BAVARIAN" b2="138 KV" b3="LD_154" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAVARIAN" b2="138 KV" b3="BAV-BOON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONECO" b2="138 KV" b3="CB834" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BOONECO" b2="138 KV" b3="SW837" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAVARIAN" b2="138 KV" b3="BAV-RENA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RENAKER" b2="138 KV" b3="CB824" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RENAKER" b2="138 KV" b3="SW827" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67020</SeqNum>
    <Name>L138.BooneCounty-Richwood-StanleyPark</Name>
    <LastEdit Timestamp="2024-06-25T13:54:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONECO" b2="138 KV" b3="CB804" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOONECO" b2="138 KV" b3="RIC-BOON" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BOONECO" b2="138 KV" b3="SW807" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RICHWOOD" b2="138 KV" b3="LD_1504" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANPARK" b2="138 KV" b3="CB824" />
      <ContingencyEquipment Action="L" Type="LN" b1="RICHWOOD" b2="138 KV" b3="RIC-STAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STANPARK" b2="138 KV" b3="SW827" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67040</SeqNum>
    <Name>L161.Liberty-CaseyCo-MarionCounty</Name>
    <LastEdit Timestamp="2025-02-18T16:05:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CASEYCO" b2="161 KV" b3="CB1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LBRTYJCT" b2="161 KV" b3="BS4_1024" />
      <ContingencyEquipment Action="L" Type="LN" b1="CASEYCO" b2="161 KV" b3="LBR-CASE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LBRTYJCT" b2="161 KV" b3="SW1021" />
      <ContingencyEquipment Action="L" Type="LN" b1="CASEYCO" b2="161 KV" b3="MAR-CASE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARIO_EK" b2="161 KV" b3="W38-1014" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MARIO_EK" b2="161 KV" b3="W38-1017" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67050</SeqNum>
    <Name>L161.Cooper-Elihu</Name>
    <LastEdit Timestamp="2024-06-25T14:08:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOP_EK" b2="161 KV" b3="CB1044" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOP_EK" b2="161 KV" b3="COO-ELIH" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COOP_EK" b2="161 KV" b3="SW1047" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIHU" b2="161 KV" b3="CB96_804" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELIHU" b2="161 KV" b3="SW96_817" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67060</SeqNum>
    <Name>L161.Cooper-Pulaski-Liberty</Name>
    <LastEdit Timestamp="2024-06-25T14:14:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOP_EK" b2="161 KV" b3="CB1024" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOP_EK" b2="161 KV" b3="COO-PULA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COOP_EK" b2="161 KV" b3="SW1027" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LBRTYJCT" b2="161 KV" b3="BS4_1014" />
      <ContingencyEquipment Action="L" Type="LN" b1="LBRTYJCT" b2="161 KV" b3="LBR-PULA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LBRTYJCT" b2="161 KV" b3="SW1011" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PULASKI3" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="X" Type="XF" b1="PULASKI3" b2="161 KV" b3="XF185" />
      <ContingencyEquipment Action="L" Type="LN" b1="PULASKI3" b2="161 KV" b3="PUL-PULA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67070</SeqNum>
    <Name>L161.Cooper-Denny</Name>
    <LastEdit Timestamp="2025-08-22T11:57:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOP_EK" b2="161 KV" b3="CB1064" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOP_EK" b2="161 KV" b3="COO-DENN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COOP_EK" b2="161 KV" b3="SW1067" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNY" b2="161 KV" b3="S27-1008" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67080</SeqNum>
    <Name>L161.Cooper-LaurelDam</Name>
    <LastEdit Timestamp="2024-06-25T14:10:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOP_EK" b2="161 KV" b3="CB1054" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOP_EK" b2="161 KV" b3="COO-LAUR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COOP_EK" b2="161 KV" b3="SW1057" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAURELDM" b2="161 KV" b3="CBL15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67090</SeqNum>
    <Name>Cooper.U1</Name>
    <LastEdit Timestamp="2024-06-25T13:34:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOP_EK" b2="161 KV" b3="CB110G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOP_EK" b2="13.8 KV" b3="CBGEN1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COOP_EK" b2="13.8 KV" b3="COOPER01" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COOP_EK" b2="13.8 KV" b3="GN1AAXLD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COOP_EK" b2="13.8 KV" b3="GN1BAXLD" />
      <ContingencyEquipment Action="X" Type="XF" b1="COOP_EK" b2="161 KV" b3="XFUN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67100</SeqNum>
    <Name>Cooper.U2</Name>
    <LastEdit Timestamp="2024-06-25T13:34:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOP_EK" b2="20 KV" b3="22G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOP_EK" b2="161 KV" b3="CB210G" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COOP_EK" b2="20 KV" b3="COOPER02" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COOP_EK" b2="20 KV" b3="GN2AAXLD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COOP_EK" b2="20 KV" b3="GN2BAXLD" />
      <ContingencyEquipment Action="X" Type="XF" b1="COOP_EK" b2="161 KV" b3="XFUN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67120</SeqNum>
    <Name>L161.Tyner-Greenhall-Delvinta</Name>
    <LastEdit Timestamp="2024-06-25T14:20:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELVINTA" b2="161 KV" b3="B139_814" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELVINTA" b2="161 KV" b3="B139_817" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELVINTA" b2="161 KV" b3="GRN-DELV" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRNHALL" b2="161 KV" b3="GRN-GRNH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRNHALL" b2="161 KV" b3="LD_143" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYNER" b2="161 KV" b3="CB1004" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRNHALLJ" b2="161 KV" b3="GRN-TYNE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TYNER" b2="161 KV" b3="SW1007" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67130</SeqNum>
    <Name>L138.Fawkes-Threeforks-Dale</Name>
    <LastEdit Timestamp="2024-06-25T13:58:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DALESTN" b2="138 KV" b3="CB_804" />
      <ContingencyEquipment Action="L" Type="LN" b1="DALESTN" b2="138 KV" b3="DAL-THRE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DALESTN" b2="138 KV" b3="SW_807" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKES" b2="138 KV" b3="CB804" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAWKES" b2="138 KV" b3="FAW-THRE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAWKES" b2="138 KV" b3="SW807" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THREFRKS" b2="138 KV" b3="LD_154" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67140</SeqNum>
    <Name>L138.Fawkes-JKSmith</Name>
    <LastEdit Timestamp="2024-06-25T11:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKES" b2="138 KV" b3="CB814" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAWKES" b2="138 KV" b3="FAW-JKSM" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAWKES" b2="138 KV" b3="SW817" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB844" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB91T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67150</SeqNum>
    <Name>L138.Fawkes-WestBerea + 138/69.WestBerea.T187</Name>
    <LastEdit Timestamp="2025-02-18T16:09:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKES" b2="138 KV" b3="CB824" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAWKES" b2="138 KV" b3="FAW-WBER" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAWKES" b2="138 KV" b3="SW827" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_BEREA" b2="69 KV" b3="S49-618" />
      <ContingencyEquipment Action="X" Type="XF" b1="W_BEREA" b2="138 KV" b3="XF187" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67160</SeqNum>
    <Name>L138.Gallatin-Ghent</Name>
    <LastEdit Timestamp="2024-06-25T11:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GALLATIN" b2="138 KV" b3="CB824" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALLATIN" b2="138 KV" b3="CB834" />
      <ContingencyEquipment Action="L" Type="LN" b1="GALLATIN" b2="138 KV" b3="GAL-GHEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="138 KV" b3="B165_714" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67170</SeqNum>
    <Name>L138.Goddard-Plumville</Name>
    <LastEdit Timestamp="2024-06-25T14:01:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GODDARD" b2="138 KV" b3="CBE5_824" />
      <ContingencyEquipment Action="L" Type="LN" b1="GODDARD" b2="138 KV" b3="GOD-PLUM" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GODDARD" b2="138 KV" b3="SW827" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLUMVILL" b2="138 KV" b3="CB814" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PLUMVILL" b2="138 KV" b3="SW817" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67190</SeqNum>
    <Name>L138.Spurlock-Flemingsburg-Goddard</Name>
    <LastEdit Timestamp="2024-10-02T14:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLMINSBG" b2="138 KV" b3="LD_4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GODDARD" b2="138 KV" b3="CBE5_814" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLMINSBG" b2="138 KV" b3="FLM-GODD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GODDARD" b2="138 KV" b3="SW817" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB844" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB92T" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLMINSBG" b2="138 KV" b3="FLM-SPU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67200</SeqNum>
    <Name>L161.GreenCounty-Summershade</Name>
    <LastEdit Timestamp="2024-06-25T14:18:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCO" b2="161 KV" b3="CB1004" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENCO" b2="161 KV" b3="GRE-SUMS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENCO" b2="161 KV" b3="SW1007" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMSHADE" b2="161 KV" b3="CB1004" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUMSHADE" b2="161 KV" b3="SW1007" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67210</SeqNum>
    <Name>L161.GreenCo-Taylor-Saloma-Mario-NLebanon-MarionCo</Name>
    <LastEdit Timestamp="2026-02-13T16:32:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCO" b2="161 KV" b3="CB1014" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENCO" b2="161 KV" b3="GRE-TAYL" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENCO" b2="161 KV" b3="SW1017" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARIONCO" b2="161 KV" b3="MAR-NLE2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARIONCO" b2="161 KV" b3="MAR-SALO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARIONCO" b2="161 KV" b3="MARIONCO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARIONCO" b2="161 KV" b3="METTS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARIONCO" b2="161 KV" b3="SMARIONC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARIONCO" b2="161 KV" b3="W1351004" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MARIONCO" b2="161 KV" b3="W90-1107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARIONCO" b2="161 KV" b3="W90-1108" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARIO_EK" b2="161 KV" b3="W38-1004" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MARIO_EK" b2="161 KV" b3="W38-1007" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEB_EK" b2="161 KV" b3="CB1024" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARIO_EK" b2="161 KV" b3="MAR-NLE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NLEB_EK" b2="161 KV" b3="NLEB_PRI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NLEB_EK" b2="161 KV" b3="NLEB_SEC" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NLEB_EK" b2="161 KV" b3="SW1027" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SALOMA" b2="161 KV" b3="LD_144" />
      <ContingencyEquipment Action="L" Type="LN" b1="SALOMA" b2="161 KV" b3="TAY-SALO" />
      <ContingencyEquipment Action="L" Type="LN" b1="TAYLORCO" b2="161 KV" b3="TAY-TAYC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAYLOR_C" b2="161 KV" b3="B200_804" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67220</SeqNum>
    <Name>345/138.JKSmith.T1</Name>
    <LastEdit Timestamp="2024-06-25T11:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="345 KV" b3="CB1418" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="345 KV" b3="CB150T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB898" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB94T" />
      <ContingencyEquipment Action="X" Type="XF" b1="JKSMT_EK" b2="345 KV" b3="XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67230</SeqNum>
    <Name>345/138.JKSmith.T2</Name>
    <LastEdit Timestamp="2024-06-25T11:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="345 KV" b3="CB1438" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="345 KV" b3="CB151T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB878" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB93T" />
      <ContingencyEquipment Action="X" Type="XF" b1="JKSMT_EK" b2="345 KV" b3="XF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67240</SeqNum>
    <Name>L345.JKSmith-WestGarrard</Name>
    <LastEdit Timestamp="2024-06-25T11:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="345 KV" b3="CB1454" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="345 KV" b3="CB152T" />
      <ContingencyEquipment Action="L" Type="LN" b1="JKSMT_EK" b2="345 KV" b3="JKS-WGAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_GARARD" b2="345 KV" b3="CB1404" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_GARARD" b2="345 KV" b3="CB150T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67250</SeqNum>
    <Name>L138.JKSmith-PowellCounty</Name>
    <LastEdit Timestamp="2026-04-27T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB854" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB92T" />
      <ContingencyEquipment Action="L" Type="LN" b1="JKSMT_EK" b2="138 KV" b3="JKS-POWE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POWELLCO" b2="138 KV" b3="CB814" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67260</SeqNum>
    <Name>L138.JKSmith-Union-LakeReba</Name>
    <LastEdit Timestamp="2024-06-25T14:05:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB864" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB92T" />
      <ContingencyEquipment Action="L" Type="LN" b1="JKSMT_EK" b2="138 KV" b3="JKS-UNIO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKE_REB" b2="138 KV" b3="B162_724" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKE_REB" b2="138 KV" b3="LAK-UNIO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNION_EK" b2="138 KV" b3="LD_155" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67270</SeqNum>
    <Name>L138.Spurlock-Kenton</Name>
    <LastEdit Timestamp="2024-06-25T11:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTN_LG" b2="138 KV" b3="B091_744" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTN_LG" b2="138 KV" b3="B091_747" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB854" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB93T" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENTN_LG" b2="138 KV" b3="SPU-KENT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67280</SeqNum>
    <Name>L161.LaurelCo-LaurelDam</Name>
    <LastEdit Timestamp="2024-06-25T11:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAURELCO" b2="161 KV" b3="CB1014" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAURELCO" b2="161 KV" b3="LAU-LAUR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAURELCO" b2="161 KV" b3="SW1027" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAURELDM" b2="161 KV" b3="CBL25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67290</SeqNum>
    <Name>L138.Avon-LoudonAve</Name>
    <LastEdit Timestamp="2024-10-16T13:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AVON_EK" b2="138 KV" b3="884" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVON_EK" b2="138 KV" b3="93T" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVON_EK" b2="138 KV" b3="AVO-LOUD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDON_A" b2="138 KV" b3="B176_707" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDON_A" b2="138 KV" b3="B176_714" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67300</SeqNum>
    <Name>161/138.MarionCo.T157</Name>
    <LastEdit Timestamp="2025-02-18T16:07:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARIO_EK" b2="161 KV" b3="W38-1038" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARIO_EK" b2="138 KV" b3="W38-808" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARIO_EK" b2="161 KV" b3="XF157" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67310</SeqNum>
    <Name>L345.NorthClark-Avon</Name>
    <LastEdit Timestamp="2024-06-28T08:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AVON_EK" b2="345 KV" b3="CB1408" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_CLARK" b2="345 KV" b3="CB1424" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_CLARK" b2="345 KV" b3="CB151T" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVON_EK" b2="345 KV" b3="NCL-AVON" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67320</SeqNum>
    <Name>L345.NorthClark-JKSmith</Name>
    <LastEdit Timestamp="2024-06-28T08:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="345 KV" b3="CB1474" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="345 KV" b3="CB153T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_CLARK" b2="345 KV" b3="CB1434" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_CLARK" b2="345 KV" b3="CB151T" />
      <ContingencyEquipment Action="L" Type="LN" b1="JKSMT_EK" b2="345 KV" b3="NCL-JKSM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67330</SeqNum>
    <Name>L161.McCreary-Jellico-Caryville-Jacksbo-NorrissHP</Name>
    <LastEdit Timestamp="2024-06-28T14:24:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSBOR" b2="161 KV" b3="JAC-CAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARYVILL" b2="161 KV" b3="LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JACKSBOR" b2="161 KV" b3="LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JELLICO" b2="161 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROYALBLU" b2="161 KV" b3="ROY-JEL" />
      <ContingencyEquipment Action="L" Type="LN" b1="JELLICO" b2="161 KV" b3="JEL-MCC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCRERYCO" b2="161 KV" b3="PCB1024" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MCRERYCO" b2="161 KV" b3="SW1027" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORRISHY" b2="161 KV" b3="944" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORRISHY" b2="161 KV" b3="948" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORRISHY" b2="161 KV" b3="NOR-JAC" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARYVILL" b2="161 KV" b3="CAR-ROY" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROYALBLU" b2="161 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67340</SeqNum>
    <Name>L138.Rowan-Rodburn</Name>
    <LastEdit Timestamp="2024-06-28T13:27:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RODBURN" b2="138 KV" b3="B090_714" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RODBURN" b2="138 KV" b3="B090_717" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROWAN_CO" b2="138 KV" b3="CB834" />
      <ContingencyEquipment Action="L" Type="LN" b1="RODBURN" b2="138 KV" b3="ROW-RODB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROWAN_CO" b2="138 KV" b3="SW837" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67350</SeqNum>
    <Name>L138.Rowan-Skaggs </Name>
    <LastEdit Timestamp="2024-06-28T14:27:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROWAN_CO" b2="138 KV" b3="CB824" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROWAN_CO" b2="138 KV" b3="ROW-SKAG" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROWAN_CO" b2="138 KV" b3="SW827" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKAGGS" b2="138 KV" b3="E35-808" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67360</SeqNum>
    <Name>L345.Spurlock-NorthClark</Name>
    <LastEdit Timestamp="2024-10-22T17:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="N_CLARK" b2="345 KV" b3="CB1414" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_CLARK" b2="345 KV" b3="CB150T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB1444" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB150T" />
      <ContingencyEquipment Action="L" Type="LN" b1="N_CLARK" b2="345 KV" b3="NCL-SPUR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67370</SeqNum>
    <Name>L138.Spurlock-Mysvl-Plumville</Name>
    <LastEdit Timestamp="2024-06-28T13:30:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MYSVL_EK" b2="138 KV" b3="LD_154" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLUMVILL" b2="138 KV" b3="CB804" />
      <ContingencyEquipment Action="L" Type="LN" b1="MYSVL_EK" b2="138 KV" b3="PLU-MYSV" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PLUMVILL" b2="138 KV" b3="SW807" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB834" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB92T" />
      <ContingencyEquipment Action="L" Type="LN" b1="MYSVL_EK" b2="138 KV" b3="SPU-MYSV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67380</SeqNum>
    <Name>L138.Spurlock-Renaker</Name>
    <LastEdit Timestamp="2024-06-28T13:31:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RENAKER" b2="138 KV" b3="CB844" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RENAKER" b2="138 KV" b3="SW847" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB824" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB91T" />
      <ContingencyEquipment Action="L" Type="LN" b1="RENAKER" b2="138 KV" b3="REN-SPUR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67390</SeqNum>
    <Name>L138.Spurlock-StanleyPark</Name>
    <LastEdit Timestamp="2024-06-28T13:33:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB814" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB91T" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPURLOCK" b2="138 KV" b3="SPU-STAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANPARK" b2="138 KV" b3="CB814" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STANPARK" b2="138 KV" b3="SW817" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67400</SeqNum>
    <Name>Spurlock.U1</Name>
    <LastEdit Timestamp="2024-06-28T13:43:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB18G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB90T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPURLOCK" b2="22 KV" b3="G1AUXLD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPURLOCK" b2="22 KV" b3="SPURLK1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPURLOCK" b2="138 KV" b3="XFUN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67410</SeqNum>
    <Name>Spurlock.U2</Name>
    <LastEdit Timestamp="2024-07-03T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB150T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB214G" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPURLOCK" b2="22 KV" b3="SPURLK2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPURLOCK" b2="345 KV" b3="XFUN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67420</SeqNum>
    <Name>Spurlock.U3</Name>
    <LastEdit Timestamp="2024-07-03T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB151T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB314G" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPURLOCK" b2="18 KV" b3="SPURLK3" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPURLOCK" b2="345 KV" b3="XFUN3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67430</SeqNum>
    <Name>Spurlock.U4</Name>
    <LastEdit Timestamp="2024-07-03T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB153T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB414G" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPURLOCK" b2="18 KV" b3="SPURLK4" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPURLOCK" b2="345 KV" b3="XFUN4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67440</SeqNum>
    <Name>345/138.Spurlock.T10</Name>
    <LastEdit Timestamp="2024-05-29T10:12:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB1438" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB888" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPURLOCK" b2="345 KV" b3="XFT10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67450</SeqNum>
    <Name>345/138.Spurlock.T12</Name>
    <LastEdit Timestamp="2024-05-29T10:12:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB1458" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB151T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB898" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB94T" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPURLOCK" b2="345 KV" b3="XFT12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67460</SeqNum>
    <Name>345/138.Spurlock.T9</Name>
    <LastEdit Timestamp="2024-05-29T10:12:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB1418" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB878" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB94T" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPURLOCK" b2="345 KV" b3="XFT9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67470</SeqNum>
    <Name>L161.SummerShade-Barren</Name>
    <LastEdit Timestamp="2024-07-03T11:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BARRENCO" b2="161 KV" b3="CB1014" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARRENCO" b2="161 KV" b3="CB1024" />
      <ContingencyEquipment Action="L" Type="LN" b1="BARRENCO" b2="161 KV" b3="BAR-SUMS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMSHADE" b2="161 KV" b3="CB1014" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67480</SeqNum>
    <Name>L138.Spurlock-Inland</Name>
    <LastEdit Timestamp="2024-12-30T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INLANDCO" b2="138 KV" b3="LD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INLANDCO" b2="138 KV" b3="LD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB864" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB93T" />
      <ContingencyEquipment Action="L" Type="LN" b1="INLANDCO" b2="138 KV" b3="INL-SPUR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67500</SeqNum>
    <Name>L161.Tyner-Pitts-Laurel Co</Name>
    <LastEdit Timestamp="2024-07-03T11:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAURELCO" b2="161 KV" b3="CB1024" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAURELCO" b2="161 KV" b3="PIT-LAUR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PITTSBUR" b2="161 KV" b3="B051_803" />
      <ContingencyEquipment Action="L" Type="LN" b1="PITTSBUR" b2="161 KV" b3="PIT-PITT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYNER" b2="161 KV" b3="CB1014" />
      <ContingencyEquipment Action="L" Type="LN" b1="PITTS_EK" b2="161 KV" b3="PIT-TYNE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67510</SeqNum>
    <Name>L161.McCreary-WayneCounty-WolfCreek</Name>
    <LastEdit Timestamp="2025-06-19T12:06:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCRERYCO" b2="161 KV" b3="CB1014" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCRERYCO" b2="161 KV" b3="MCC-WAY" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MCRERYCO" b2="161 KV" b3="SW1017" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAYNECK" b2="161 KV" b3="WAY-WYEK" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WOLF_CRK" b2="161 KV" b3="955" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLF_CRK" b2="161 KV" b3="958" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAYNECK" b2="161 KV" b3="WAY-5WO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYNCO_EK" b2="161 KV" b3="996_1008" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67540</SeqNum>
    <Name>138/69.GeorgeWashington.T2</Name>
    <LastEdit Timestamp="2024-12-12T10:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="69 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="138 KV" b3="R2" />
      <ContingencyEquipment Action="X" Type="XF" b1="GEORGEWA" b2="138 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67550</SeqNum>
    <Name>138/69.GeorgeWashington.T1</Name>
    <LastEdit Timestamp="2025-01-06T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="138 KV" b3="P1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GEORGEWA" b2="138 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67600</SeqNum>
    <Name>Shipbottom.69.Cap.1</Name>
    <LastEdit Timestamp="2024-11-18T08:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="SHIPBOTT" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHIPBOTT" b2="69 KV" b3="GCB B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHIPBOTT" b2="69 KV" b3="GCB J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67630</SeqNum>
    <Name>L161.Alcalde-Elihu</Name>
    <LastEdit Timestamp="2024-07-12T13:56:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ALCALDE" b2="161 KV" b3="807" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALCALDE" b2="161 KV" b3="B194_804" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCALDE" b2="161 KV" b3="ELI-ALCA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIHU" b2="161 KV" b3="CB96_814" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELIHU" b2="161 KV" b3="SW96_817" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67640</SeqNum>
    <Name>230/138.Harmony.AT21</Name>
    <LastEdit Timestamp="2024-07-03T11:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="230 KV" b3="237" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="230 KV" b3="238" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARMONY" b2="230 KV" b3="AT21" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67720</SeqNum>
    <Name>138/115.Edinburg.TX4</Name>
    <LastEdit Timestamp="2025-09-02T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDINBUR4" b2="138 KV" b3="H412" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDINBUR4" b2="115 KV" b3="L412" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDINBUR4" b2="138 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67780</SeqNum>
    <Name>L138.BlackRiver-RepVine</Name>
    <LastEdit Timestamp="2024-07-03T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKRIV" b2="138 KV" b3="BLA-REPV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REPVINE" b2="138 KV" b3="1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67840</SeqNum>
    <Name>161/69.Cooper.T1829</Name>
    <LastEdit Timestamp="2024-07-05T14:16:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOP_EK" b2="161 KV" b3="CB1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOP_EK" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COOP_EK" b2="161 KV" b3="SW1007" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COOP_EK" b2="69 KV" b3="SW607" />
      <ContingencyEquipment Action="X" Type="XF" b1="COOP_EK" b2="161 KV" b3="XF1829" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67850</SeqNum>
    <Name>L161.Cooper-SouthOakHill-Jabez-RusselCo-WolfCreek</Name>
    <LastEdit Timestamp="2025-11-24T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOP_EK" b2="161 KV" b3="CB1014" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOP_EK" b2="161 KV" b3="COO-SOAK" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COOP_EK" b2="161 KV" b3="SW1017" />
      <ContingencyEquipment Action="L" Type="LN" b1="JABEZ" b2="161 KV" b3="JAB-JABE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JABEZ" b2="161 KV" b3="LD_143" />
      <ContingencyEquipment Action="L" Type="LN" b1="JABEZTAP" b2="161 KV" b3="JAB-SOAK" />
      <ContingencyEquipment Action="L" Type="LN" b1="JABEZTAP" b2="161 KV" b3="JAM-JABE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JAMESTWN" b2="161 KV" b3="LD_153" />
      <ContingencyEquipment Action="L" Type="LN" b1="JAMESTWN" b2="161 KV" b3="RUS-JAME" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSELCO" b2="161 KV" b3="CB1008" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUSSELJC" b2="161 KV" b3="20R-5WO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUSSELCO" b2="161 KV" b3="RUS-RUSC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOAKHILL" b2="161 KV" b3="LD_163" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WOLF_CRK" b2="161 KV" b3="985" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLF_CRK" b2="161 KV" b3="988" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67860</SeqNum>
    <Name>L345.Austin-Pana</Name>
    <LastEdit Timestamp="2024-09-30T14:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AUSTIN" b2="345 KV" b3="AUS-PAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUSTIN" b2="345 KV" b3="V33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUSTIN" b2="345 KV" b3="V35" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANA" b2="345 KV" b3="V41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANA" b2="345 KV" b3="V43" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67870</SeqNum>
    <Name>138/69.Argentum.T187</Name>
    <LastEdit Timestamp="2026-01-09T15:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGNT_EK" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGNT_EK" b2="138 KV" b3="CB808" />
      <ContingencyEquipment Action="X" Type="XF" b1="ARGNT_EK" b2="138 KV" b3="XF187" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67880</SeqNum>
    <Name>L138.Argentum-GreenupHydro</Name>
    <LastEdit Timestamp="2024-08-06T11:42:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGNT_EK" b2="138 KV" b3="CB834" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ARGNT_EK" b2="138 KV" b3="SW837" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARGNT_EK" b2="138 KV" b3="ARG-GREE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENUP" b2="138 KV" b3="ARGE" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GREENUP" b2="4 KV" b3="G1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GREENUP" b2="4 KV" b3="G2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GREENUP" b2="4 KV" b3="G3" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENUP" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENUP" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENUP" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67900</SeqNum>
    <Name>L345.Coffeen-Pana (Ameren)</Name>
    <LastEdit Timestamp="2025-04-28T15:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COFFEN 3" b2="345 KV" b3="3541" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COFFEN 3" b2="345 KV" b3="3544" />
      <ContingencyEquipment Action="L" Type="LN" b1="COFFEN 3" b2="345 KV" b3="COF-PAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANA" b2="345 KV" b3="V31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANA" b2="345 KV" b3="V33" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67910</SeqNum>
    <Name>161/69.BarrenCounty.T187</Name>
    <LastEdit Timestamp="2024-07-03T11:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BARRENCO" b2="161 KV" b3="CB1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARRENCO" b2="69 KV" b3="CB628" />
      <ContingencyEquipment Action="X" Type="XF" b1="BARRENCO" b2="161 KV" b3="XF187" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67920</SeqNum>
    <Name>345/138.Pana.TR1</Name>
    <LastEdit Timestamp="2024-09-25T14:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PANA" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PANA" b2="345 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANA" b2="345 KV" b3="V33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANA" b2="345 KV" b3="V35" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67930</SeqNum>
    <Name>L345.Faraday-Pana</Name>
    <LastEdit Timestamp="2024-09-24T16:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARADAY" b2="345 KV" b3="V21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARADAY" b2="345 KV" b3="V25" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARADAY" b2="345 KV" b3="FAR-PAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANA" b2="345 KV" b3="V53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANA" b2="345 KV" b3="V55" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67940</SeqNum>
    <Name>L138.Avon-ParisTap-Paris-Jacksonvil-HarrisonCounty</Name>
    <LastEdit Timestamp="2024-10-18T16:23:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AVON_EK" b2="138 KV" b3="894" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVON_EK" b2="138 KV" b3="93T" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVON_EK" b2="138 KV" b3="PAR-AVON" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRCOEK" b2="138 KV" b3="HAR-JACK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRCOEK" b2="138 KV" b3="N101-824" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARRCOEK" b2="138 KV" b3="N101-827" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JACKSNVL" b2="138 KV" b3="LD_154" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSNVL" b2="138 KV" b3="PAR-JACK" />
      <ContingencyEquipment Action="L" Type="LN" b1="PARISTAP" b2="138 KV" b3="PAR-PARI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARIS_SU" b2="138 KV" b3="B021_704" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67950</SeqNum>
    <Name>JKSmith.U4</Name>
    <LastEdit Timestamp="2024-07-03T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB48G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="13.8 KV" b3="GEN4BK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JKSMT_EK" b2="13.8 KV" b3="JKSMT4" />
      <ContingencyEquipment Action="X" Type="XF" b1="JKSMT_EK" b2="138 KV" b3="XFCT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67960</SeqNum>
    <Name>JKSmith.U9&amp;U10</Name>
    <LastEdit Timestamp="2024-07-03T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="345 KV" b3="CB114G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="345 KV" b3="CB150T" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JKSMT_EK" b2="13.8 KV" b3="JKSMT10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JKSMT_EK" b2="13.8 KV" b3="JKSMT9" />
      <ContingencyEquipment Action="X" Type="XF" b1="JKSMT_EK" b2="345 KV" b3="XFCT10" />
      <ContingencyEquipment Action="X" Type="XF" b1="JKSMT_EK" b2="345 KV" b3="XFCT9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67970</SeqNum>
    <Name>L138.BakerL2-BakerLaneTap-Brown-HigbyMill</Name>
    <LastEdit Timestamp="2025-07-24T16:31:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER_L2" b2="138 KV" b3="W102_808" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAKER_L2" b2="138 KV" b3="BAK-BAKE" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAKER_LN" b2="138 KV" b3="BAK-BROW" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAKER_LN" b2="138 KV" b3="BAK-HIGB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_NO" b2="138 KV" b3="B152_767" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGBY_MI" b2="138 KV" b3="B066_744" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGBY_MI" b2="138 KV" b3="B066_747" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67980</SeqNum>
    <Name>JKSmith.U3</Name>
    <LastEdit Timestamp="2024-07-03T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB38G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="13.8 KV" b3="GEN3BK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JKSMT_EK" b2="13.8 KV" b3="JKSMT3" />
      <ContingencyEquipment Action="X" Type="XF" b1="JKSMT_EK" b2="138 KV" b3="XFCT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>67990</SeqNum>
    <Name>L138.Bonnieville-Bonnievl+ 138/69.Bnnvl.T187</Name>
    <LastEdit Timestamp="2026-05-08T12:00:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BONNIEVL" b2="138 KV" b3="BON-BONN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BONNIEVL" b2="69 KV" b3="W144-707" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BONNIEVL" b2="69 KV" b3="W8-628" />
      <ContingencyEquipment Action="X" Type="XF" b1="BONNIEVL" b2="138 KV" b3="XF183" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BONVL_LG" b2="69 KV" b3="B064_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BONVL_LG" b2="138 KV" b3="B064_704" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BONVL_LG" b2="138 KV" b3="B064_714" />
      <ContingencyEquipment Action="X" Type="XF" b1="BONVL_LG" b2="138 KV" b3="XF187" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68000</SeqNum>
    <Name>JKSmith.U2</Name>
    <LastEdit Timestamp="2024-07-03T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB28G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="13.8 KV" b3="GEN2BK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JKSMT_EK" b2="13.8 KV" b3="JKSMT2" />
      <ContingencyEquipment Action="X" Type="XF" b1="JKSMT_EK" b2="138 KV" b3="XFCT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68010</SeqNum>
    <Name>L161.PowellCo-MillersCrk-BeattyVille-Delvinta</Name>
    <LastEdit Timestamp="2026-04-14T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTYVL" b2="161 KV" b3="B111_803" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEATTYVL" b2="161 KV" b3="BEA-BTYV" />
      <ContingencyEquipment Action="L" Type="LN" b1="BTYVLJCT" b2="161 KV" b3="BTY-DELV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELVINTA" b2="161 KV" b3="B139_834" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELVINTA" b2="161 KV" b3="B139_837" />
      <ContingencyEquipment Action="L" Type="LN" b1="BTYVLJCT" b2="161 KV" b3="BTY-MILL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILLCRK" b2="161 KV" b3="MCLD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLCRK" b2="161 KV" b3="MLC-POWE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POWELLCO" b2="161 KV" b3="1008" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68020</SeqNum>
    <Name>JKSmith.U1</Name>
    <LastEdit Timestamp="2024-07-03T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB18G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="13.8 KV" b3="GEN1BK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JKSMT_EK" b2="13.8 KV" b3="JKSMT1" />
      <ContingencyEquipment Action="X" Type="XF" b1="JKSMT_EK" b2="138 KV" b3="XFCT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68030</SeqNum>
    <Name>JKSmith.U7</Name>
    <LastEdit Timestamp="2024-07-03T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB78G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="13.8 KV" b3="GEN7BK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JKSMT_EK" b2="13.8 KV" b3="JKSMT7" />
      <ContingencyEquipment Action="X" Type="XF" b1="JKSMT_EK" b2="138 KV" b3="XFCT7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68040</SeqNum>
    <Name>JKSmith.U6</Name>
    <LastEdit Timestamp="2024-07-05T13:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB68G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="13.8 KV" b3="GEN6BK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JKSMT_EK" b2="13.8 KV" b3="JKSMT6" />
      <ContingencyEquipment Action="X" Type="XF" b1="JKSMT_EK" b2="138 KV" b3="XFCT6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68050</SeqNum>
    <Name>JKSmith.U5</Name>
    <LastEdit Timestamp="2024-07-05T13:44:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="13.8 KV" b3="GEN5BK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JKSMT_EK" b2="13.8 KV" b3="JKSMT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68060</SeqNum>
    <Name>138/69.BakerL2.T151</Name>
    <LastEdit Timestamp="2024-07-05T14:19:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER_L2" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER_L2" b2="138 KV" b3="W102_808" />
      <ContingencyEquipment Action="X" Type="XF" b1="BAKER_L2" b2="138 KV" b3="XF151" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68070</SeqNum>
    <Name>L161.BullittCo-SummerShadeTap-SummerShade (Tie)</Name>
    <LastEdit Timestamp="2025-03-28T15:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BULLITCO" b2="161 KV" b3="BUL-SUMS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLITCO" b2="161 KV" b3="CB1024" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BULLITCO" b2="161 KV" b3="SW1027" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUMMER" b2="161 KV" b3="983" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMER" b2="161 KV" b3="988" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMSHADE" b2="161 KV" b3="CB1044" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUMSHADE" b2="161 KV" b3="SUM-SUMS" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUMMER" b2="161 KV" b3="SUM-SUMT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68080</SeqNum>
    <Name>LaurelDam.U1</Name>
    <LastEdit Timestamp="2024-07-05T13:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAURELDM" b2="13.8 KV" b3="CBD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAURELDM" b2="13.8 KV" b3="CBE" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LAURELDM" b2="13.8 KV" b3="LAUREL" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAURELDM" b2="161 KV" b3="XFUN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68090</SeqNum>
    <Name>161/69.BullittCounty.T189</Name>
    <LastEdit Timestamp="2024-07-05T11:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLITCO" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLITCO" b2="161 KV" b3="SW1008CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BULLITCO" b2="161 KV" b3="XF189" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68100</SeqNum>
    <Name>L138.CentralHarding-HardinCo(Tie)</Name>
    <LastEdit Timestamp="2025-08-11T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CNTRLHAR" b2="138 KV" b3="CB814" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CNTRLHAR" b2="138 KV" b3="CB91T" />
      <ContingencyEquipment Action="L" Type="LN" b1="CNTRLHAR" b2="138 KV" b3="CNT-HARD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="138 KV" b3="CB712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="138 KV" b3="CB714" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68110</SeqNum>
    <Name>L161.BulitCo-Taylrsv-Litlmtnt-DrwinThomas-ShelbyCo</Name>
    <LastEdit Timestamp="2026-01-27T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLITCO" b2="161 KV" b3="CB1034" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BULLITCO" b2="161 KV" b3="SW1037" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DARWINTO" b2="161 KV" b3="LD_144" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARWINTO" b2="161 KV" b3="LIT-DARW" />
      <ContingencyEquipment Action="L" Type="LN" b1="LITLMTNT" b2="161 KV" b3="LIT-LTLM" />
      <ContingencyEquipment Action="L" Type="LN" b1="LITLMTNT" b2="161 KV" b3="LIT-TAYL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LTLMOUNT" b2="161 KV" b3="LD_142" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARWINTO" b2="161 KV" b3="DAR-SHEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBYCO" b2="161 KV" b3="N53-1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBYCO" b2="69 KV" b3="N53-608" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHELBYCO" b2="161 KV" b3="XF186" />
      <ContingencyEquipment Action="L" Type="LN" b1="BULLITCO" b2="161 KV" b3="BUL-TAYL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAYLRSVI" b2="161 KV" b3="CB1029" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68120</SeqNum>
    <Name>L138.RowanC-Cranstop-Goddard</Name>
    <LastEdit Timestamp="2025-03-18T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRANSTOP" b2="138 KV" b3="CRA-GOD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRANSTOP" b2="138 KV" b3="LD_155" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GODDARD" b2="138 KV" b3="CBE5_834" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GODDARD" b2="138 KV" b3="SW837" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROWAN_CO" b2="138 KV" b3="CB814" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRANSTOP" b2="138 KV" b3="CRA-ROWA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROWAN_CO" b2="138 KV" b3="SW817" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68130</SeqNum>
    <Name>L161.Tyner-Fallrock+161/69.Fallrock.XF</Name>
    <LastEdit Timestamp="2024-11-18T13:06:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLROCK" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="L" Type="LN" b1="FALLROCK" b2="161 KV" b3="FAL-TYNE" />
      <ContingencyEquipment Action="X" Type="XF" b1="FALLROCK" b2="161 KV" b3="XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYNER" b2="161 KV" b3="CB1024" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TYNER" b2="161 KV" b3="SW1027" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68140</SeqNum>
    <Name>L138.Fawkes-FawkesTap-FawkesLG-LakeReba</Name>
    <LastEdit Timestamp="2024-11-15T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKES" b2="138 KV" b3="CB834" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAWKES" b2="138 KV" b3="SW837" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKESLG" b2="138 KV" b3="B102_724" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKESLG" b2="138 KV" b3="B102_727" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAWKESLG" b2="138 KV" b3="FAW-FAWK" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAWKES" b2="138 KV" b3="FAW-FAWT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKE_REB" b2="138 KV" b3="B162_704" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAWKESTP" b2="138 KV" b3="LAK-FAWK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68150</SeqNum>
    <Name>138/68.NelsonC.T185</Name>
    <LastEdit Timestamp="2025-08-01T15:04:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON_C" b2="69 KV" b3="W76-608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON_C" b2="138 KV" b3="W76-808" />
      <ContingencyEquipment Action="X" Type="XF" b1="NELSON_C" b2="138 KV" b3="XF185" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68170</SeqNum>
    <Name>138/69.BooneCounty.T1811</Name>
    <LastEdit Timestamp="2024-07-05T11:07:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONECO" b2="69 KV" b3="CB638" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONECO" b2="138 KV" b3="N15-848" />
      <ContingencyEquipment Action="X" Type="XF" b1="BOONECO" b2="138 KV" b3="XF1811" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68180</SeqNum>
    <Name>138/69.CentralHardin.TXF</Name>
    <LastEdit Timestamp="2024-07-05T11:11:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CNTRLHAR" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CNTRLHAR" b2="138 KV" b3="CB804" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CNTRLHAR" b2="138 KV" b3="CB814" />
      <ContingencyEquipment Action="X" Type="XF" b1="CNTRLHAR" b2="138 KV" b3="XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68190</SeqNum>
    <Name>138/69.DaleStation.T1817</Name>
    <LastEdit Timestamp="2024-07-05T11:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DALESTN" b2="69 KV" b3="CB_718" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DALESTN" b2="138 KV" b3="CB_828" />
      <ContingencyEquipment Action="X" Type="XF" b1="DALESTN" b2="138 KV" b3="XF1817" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68200</SeqNum>
    <Name>138/69.RowanCounty.XF186</Name>
    <LastEdit Timestamp="2025-01-23T18:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROWAN_CO" b2="69 KV" b3="608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROWAN_CO" b2="138 KV" b3="CB808" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROWAN_CO" b2="138 KV" b3="XF186" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68210</SeqNum>
    <Name>161/69.FallRock.TXF</Name>
    <LastEdit Timestamp="2024-07-05T11:16:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLROCK" b2="161 KV" b3="CB1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLROCK" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="X" Type="XF" b1="FALLROCK" b2="161 KV" b3="XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68220</SeqNum>
    <Name>345/138.Pana.TR3</Name>
    <LastEdit Timestamp="2024-09-26T14:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PANA" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="X" Type="XF" b1="PANA" b2="345 KV" b3="TR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANA" b2="345 KV" b3="V43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANA" b2="345 KV" b3="V45" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68230</SeqNum>
    <Name>L69.Nicholasville-HollowayJct-BakersLane</Name>
    <LastEdit Timestamp="2024-12-09T15:05:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAKER_L2" b2="69 KV" b3="BAK-HOLL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER_L2" b2="69 KV" b3="CB644" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLLOWYJ" b2="69 KV" b3="HOL-WNI" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLLOWYJ" b2="69 KV" b3="HOL-NIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NICHLSVL" b2="69 KV" b3="W30-634" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NICHLSVL" b2="69 KV" b3="W30-637" />
      <ContingencyEquipment Action="L" Type="LN" b1="NICHOLAS" b2="69 KV" b3="NIC-WNI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NICHOLAS" b2="69 KV" b3="SW665" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="S_JESSMJ" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="W_NICHS2" b2="69 KV" b3="LD_184" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="W_NICHVJ" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="W_NICHS2" b2="69 KV" b3="WNI-WNIJ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68240</SeqNum>
    <Name>138/69.Goddard.T185</Name>
    <LastEdit Timestamp="2024-07-05T11:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GODDARD" b2="69 KV" b3="CBE5_628" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GODDARD" b2="138 KV" b3="CBE5_808" />
      <ContingencyEquipment Action="X" Type="XF" b1="GODDARD" b2="138 KV" b3="XF185" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68250</SeqNum>
    <Name>138/69.Powell.T189</Name>
    <LastEdit Timestamp="2024-12-03T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POWELLCO" b2="138 KV" b3="808" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POWELLCO" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="X" Type="XF" b1="POWELLCO" b2="138 KV" b3="XF189" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68260</SeqNum>
    <Name>161/69.LaurelCo.T188</Name>
    <LastEdit Timestamp="2024-07-05T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAURELCO" b2="161 KV" b3="CB1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAURELCO" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAURELCO" b2="161 KV" b3="XF188" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68270</SeqNum>
    <Name>161/69.LibertyJct.T189</Name>
    <LastEdit Timestamp="2025-11-04T09:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LBRTYJCT" b2="161 KV" b3="1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LBRTYJCT" b2="69 KV" b3="CB638" />
      <ContingencyEquipment Action="X" Type="XF" b1="LBRTYJCT" b2="161 KV" b3="XF189" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68280</SeqNum>
    <Name>138/69.StanleyParker.T188</Name>
    <LastEdit Timestamp="2024-07-05T11:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STANPARK" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANPARK" b2="138 KV" b3="CB808" />
      <ContingencyEquipment Action="X" Type="XF" b1="STANPARK" b2="138 KV" b3="XF188" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68300</SeqNum>
    <Name>161/69.Tyner.T1811</Name>
    <LastEdit Timestamp="2026-01-09T15:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TYNER" b2="161 KV" b3="CB1048" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYNER" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="X" Type="XF" b1="TYNER" b2="161 KV" b3="XF1811" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68310</SeqNum>
    <Name>161/69.WayneCo.T1</Name>
    <LastEdit Timestamp="2024-07-05T15:04:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WYNCO_EK" b2="69 KV" b3="5996_628" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYNCO_EK" b2="161 KV" b3="996_1008" />
      <ContingencyEquipment Action="X" Type="XF" b1="WYNCO_EK" b2="161 KV" b3="XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68320</SeqNum>
    <Name>161/69.McCearyCo.TBK</Name>
    <LastEdit Timestamp="2024-07-05T11:18:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MCRERYCO" b2="161 KV" b3="BK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCRERYCO" b2="161 KV" b3="CB1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCRERYCO" b2="69 KV" b3="MIMIC608" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68330</SeqNum>
    <Name>138/69.Plumvill.T189</Name>
    <LastEdit Timestamp="2025-08-26T17:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLUMVILL" b2="69 KV" b3="CB648" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLUMVILL" b2="138 KV" b3="N34-838" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLUMVILL" b2="138 KV" b3="XF189" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68340</SeqNum>
    <Name>Ghent_LG.U02 (LGEE)</Name>
    <LastEdit Timestamp="2026-05-20T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_923" />
      <ContingencyEquipment Action="X" Type="XF" b1="GHENT_LG" b2="345 KV" b3="GH2GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GHENT_LG" b2="22 KV" b3="GHENT02" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68350</SeqNum>
    <Name>Ghent_LG.U03 (LGEE)</Name>
    <LastEdit Timestamp="2026-05-20T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_933" />
      <ContingencyEquipment Action="X" Type="XF" b1="GHENT_LG" b2="345 KV" b3="GH3GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GHENT_LG" b2="22 KV" b3="GHENT03" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68360</SeqNum>
    <Name>Ghent_LG.U04 (LGEE)</Name>
    <LastEdit Timestamp="2026-05-20T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_943" />
      <ContingencyEquipment Action="X" Type="XF" b1="GHENT_LG" b2="345 KV" b3="GH4GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GHENT_LG" b2="22 KV" b3="GHENT04" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68390</SeqNum>
    <Name>Haefling.U1</Name>
    <LastEdit Timestamp="2024-07-05T12:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAEFLING" b2="69 KV" b3="B127_608" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HAEFLING" b2="13.8 KV" b3="HAEFLING" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAEFLING" b2="69 KV" b3="XF2617" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68400</SeqNum>
    <Name>MillCreek.U1</Name>
    <LastEdit Timestamp="2024-07-05T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="4501_31T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="BMC_4501" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILL_CRE" b2="345 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MILL_CRE" b2="22 KV" b3="MILLCRK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68410</SeqNum>
    <Name>MillCreek.U2</Name>
    <LastEdit Timestamp="2024-07-05T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="4502_32T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="BMC_4502" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILL_CRE" b2="345 KV" b3="GSU2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MILL_CRE" b2="22 KV" b3="MILLCRK2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68420</SeqNum>
    <Name>MillCreek.U3</Name>
    <LastEdit Timestamp="2024-07-05T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="4503_33T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="BMC_4503" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILL_CRE" b2="345 KV" b3="GSU3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MILL_CRE" b2="22 KV" b3="MILLCRK3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68430</SeqNum>
    <Name>MillCreek.U4</Name>
    <LastEdit Timestamp="2024-07-05T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="4504_60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="BMC_4504" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILL_CRE" b2="345 KV" b3="GSU4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MILL_CRE" b2="22 KV" b3="MILLCRK4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68440</SeqNum>
    <Name>BrwnPlnt.U1</Name>
    <LastEdit Timestamp="2024-07-05T13:52:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRWNPLNT" b2="138 KV" b3="B117_716" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRWNPLNT" b2="13.8 KV" b3="EBROWN1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRWNPLNT" b2="138 KV" b3="XF2603" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68450</SeqNum>
    <Name>BrwnPlnt.U2</Name>
    <LastEdit Timestamp="2024-07-05T13:54:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRWNPLNT" b2="138 KV" b3="B117_726" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRWNPLNT" b2="18 KV" b3="EBROWN2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRWNPLNT" b2="138 KV" b3="XF2613" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68460</SeqNum>
    <Name>BrownNo.U3</Name>
    <LastEdit Timestamp="2024-07-05T13:50:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_NO" b2="138 KV" b3="B152_736" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BROWN_NO" b2="24 KV" b3="EBROWN3" />
      <ContingencyEquipment Action="X" Type="XF" b1="BROWN_NO" b2="138 KV" b3="XF3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68470</SeqNum>
    <Name>BrownCT.U5</Name>
    <LastEdit Timestamp="2024-07-05T13:29:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_CT" b2="138 KV" b3="B227_756" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BROWN_CT" b2="138 KV" b3="EBROWN5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68480</SeqNum>
    <Name>BrownCT.U6</Name>
    <LastEdit Timestamp="2024-07-05T13:36:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_CT" b2="138 KV" b3="B227_766" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BROWN_CT" b2="138 KV" b3="EBROWN6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68490</SeqNum>
    <Name>BrownCT.U7</Name>
    <LastEdit Timestamp="2024-07-05T13:41:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_CT" b2="138 KV" b3="B227_776" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BROWN_CT" b2="138 KV" b3="EBROWN7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68500</SeqNum>
    <Name>BrownCT.U8</Name>
    <LastEdit Timestamp="2024-07-05T13:41:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_CT" b2="138 KV" b3="B227_786" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BROWN_CT" b2="138 KV" b3="EBROWN8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68510</SeqNum>
    <Name>BrownCT.U9</Name>
    <LastEdit Timestamp="2024-07-05T13:41:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_CT" b2="138 KV" b3="B227_796" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BROWN_CT" b2="138 KV" b3="EBROWN9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68520</SeqNum>
    <Name>BrownCT.U10</Name>
    <LastEdit Timestamp="2024-07-08T08:48:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_CT" b2="138 KV" b3="227_7106" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BROWN_CT" b2="138 KV" b3="EBROWN10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68530</SeqNum>
    <Name>BrownCT.U11</Name>
    <LastEdit Timestamp="2024-07-08T08:49:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_CT" b2="138 KV" b3="227_7116" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BROWN_CT" b2="138 KV" b3="EBROWN11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68540</SeqNum>
    <Name>TrimbleCounty.U1</Name>
    <LastEdit Timestamp="2024-07-08T09:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="4511_41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="BTC_4511" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRMBL_LG" b2="21 KV" b3="TRIMBL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68550</SeqNum>
    <Name>TrimbleCounty.U2</Name>
    <LastEdit Timestamp="2024-07-08T09:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="4512_42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="TC_4512" />
      <ContingencyEquipment Action="X" Type="XF" b1="TRMBL_LG" b2="345 KV" b3="TRANS2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRMBL_LG" b2="24 KV" b3="TRIMBL2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68560</SeqNum>
    <Name>TrimbleCounty.U5</Name>
    <LastEdit Timestamp="2024-07-08T09:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="CBTCTTR5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRMBL_LG" b2="345 KV" b3="TRIMBL5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68570</SeqNum>
    <Name>TrimbleCounty.U6</Name>
    <LastEdit Timestamp="2024-07-08T09:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="CBTCTTR6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRMBL_LG" b2="345 KV" b3="TRIMBL6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68580</SeqNum>
    <Name>TrimbleCounty.U7</Name>
    <LastEdit Timestamp="2024-07-08T09:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="CBTCTTR7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRMBL_LG" b2="345 KV" b3="TRIMBL7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68590</SeqNum>
    <Name>TrimbleCounty.U8</Name>
    <LastEdit Timestamp="2024-07-08T09:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="CBTCTTR8" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRMBL_LG" b2="345 KV" b3="TRIMBL8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68600</SeqNum>
    <Name>TrimbleCounty.U9</Name>
    <LastEdit Timestamp="2024-07-08T09:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="CBTCTTR9" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRMBL_LG" b2="345 KV" b3="TRIMBL9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68610</SeqNum>
    <Name>TrimbleCounty.U10</Name>
    <LastEdit Timestamp="2024-07-08T09:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="BTCTTR10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRMBL_LG" b2="345 KV" b3="TRIMBL10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68650</SeqNum>
    <Name>L138.ScottCo-OwenCo-Ghent</Name>
    <LastEdit Timestamp="2024-07-10T16:13:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="138 KV" b3="722" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="138 KV" b3="B165_724" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OWEN_CO" b2="138 KV" b3="CB815" />
      <ContingencyEquipment Action="L" Type="LN" b1="OWEN_CO" b2="138 KV" b3="OWE-OWEN" />
      <ContingencyEquipment Action="L" Type="LN" b1="GHENT_LG" b2="138 KV" b3="OWE-GHEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOTT_CO" b2="138 KV" b3="B145_704" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOTT_CO" b2="138 KV" b3="B145_707" />
      <ContingencyEquipment Action="L" Type="LN" b1="OWEN_COU" b2="138 KV" b3="OWE-SCOT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68660</SeqNum>
    <Name>L138.Lebanon-MercerCo</Name>
    <LastEdit Timestamp="2024-07-08T09:00:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LEBANON3" b2="138 KV" b3="B043_707" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEBANON3" b2="138 KV" b3="B043_714" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEBANON3" b2="138 KV" b3="MER-LEBA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCER_C" b2="138 KV" b3="B204_715" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68670</SeqNum>
    <Name>L138.Lebanon-Mario</Name>
    <LastEdit Timestamp="2025-02-18T16:07:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEBANON3" b2="69 KV" b3="B043_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEBANON3" b2="69 KV" b3="B043_618" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEBANON3" b2="138 KV" b3="B043_704" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEBANON3" b2="138 KV" b3="B043_714" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEBANON3" b2="138 KV" b3="MAR-LEBA" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEBANON3" b2="138 KV" b3="XF187" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEBANON3" b2="138 KV" b3="XF189" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARIO_EK" b2="138 KV" b3="W38-808" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68680</SeqNum>
    <Name>L138.ScottCo-RogerGP-ToyotaNorth</Name>
    <LastEdit Timestamp="2025-07-28T11:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="4ROGR_GP" b2="138 KV" b3="153" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOTT_CO" b2="138 KV" b3="B145_714" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOTT_CO" b2="138 KV" b3="B145_717" />
      <ContingencyEquipment Action="L" Type="LN" b1="4ROGR_GP" b2="138 KV" b3="ROG-SCOT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOYOTA_N" b2="138 KV" b3="B220_704" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOYOTA_N" b2="138 KV" b3="B220_707" />
      <ContingencyEquipment Action="L" Type="LN" b1="4ROGR_GP" b2="138 KV" b3="ROG-TOYO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68690</SeqNum>
    <Name>L138.Adams-ScottCo</Name>
    <LastEdit Timestamp="2024-07-08T09:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMS_KU" b2="138 KV" b3="B108_724" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMS_KU" b2="138 KV" b3="B108_727" />
      <ContingencyEquipment Action="L" Type="LN" b1="ADAMS_KU" b2="138 KV" b3="SCT-ADAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOTT_CO" b2="138 KV" b3="B145_724" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOTT_CO" b2="138 KV" b3="B145_727" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68700</SeqNum>
    <Name>L138.Lebanon-Lebanont-Bonnieville</Name>
    <LastEdit Timestamp="2024-07-09T13:02:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BONVL_LG" b2="138 KV" b3="B064_707" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BONVL_LG" b2="138 KV" b3="B064_714" />
      <ContingencyEquipment Action="L" Type="LN" b1="BONVL_LG" b2="138 KV" b3="LEB-BONV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEBANON3" b2="138 KV" b3="B043_704" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LEBANON3" b2="138 KV" b3="B043_707" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEBANON3" b2="138 KV" b3="LEB-LEB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEBANONT" b2="138 KV" b3="B874_708" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68710</SeqNum>
    <Name>345/138.Smith.TA+L345.Smith-DaviesCounty</Name>
    <LastEdit Timestamp="2024-07-09T12:44:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIESCO" b2="345 KV" b3="CB902" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIESCO" b2="345 KV" b3="CB904" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITH" b2="138 KV" b3="776" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITH" b2="138 KV" b3="788" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITH" b2="345 KV" b3="834" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITH" b2="345 KV" b3="836" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMITH" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAVIESCO" b2="345 KV" b3="DAV-SMI1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68720</SeqNum>
    <Name>L138.Leitchfield-Shrewsbury</Name>
    <LastEdit Timestamp="2024-07-10T16:09:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEITCHFI" b2="138 KV" b3="B168_708" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEITCHFI" b2="138 KV" b3="SHR-LEIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHREWSBU" b2="138 KV" b3="B169_705" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHREWSBU" b2="138 KV" b3="B169_715" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68730</SeqNum>
    <Name>L138.Rodburn-Sharkey-Farmers-Spencer</Name>
    <LastEdit Timestamp="2024-07-10T16:11:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMERS2" b2="138 KV" b3="B175_703" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMERS2" b2="138 KV" b3="FAR-FARM" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMERSP" b2="138 KV" b3="FAR-SHAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RODBURN" b2="138 KV" b3="B090_704" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RODBURN" b2="138 KV" b3="B090_707" />
      <ContingencyEquipment Action="L" Type="LN" b1="RODBURN" b2="138 KV" b3="ROD-SHAR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHARKEY" b2="138 KV" b3="907" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARKEY" b2="138 KV" b3="CB908" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPENCER2" b2="138 KV" b3="B018_717" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPENCER2" b2="138 KV" b3="B018_724" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMERSP" b2="138 KV" b3="SPE-FARM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68740</SeqNum>
    <Name>138/69.Smith.TR4+L69.Smith-GreenRiverSteel10</Name>
    <LastEdit Timestamp="2024-07-10T16:26:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SMITH" b2="69 KV" b3="12G-SMI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREEN_RL" b2="69 KV" b3="B100_648" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMITH" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITH" b2="69 KV" b3="614" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITH" b2="69 KV" b3="618" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITH" b2="138 KV" b3="748" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITH" b2="138 KV" b3="754" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68750</SeqNum>
    <Name>138/69.AdamsKu.T188</Name>
    <LastEdit Timestamp="2024-07-09T12:21:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMS_KU" b2="69 KV" b3="B108_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMS_KU" b2="138 KV" b3="B108_708" />
      <ContingencyEquipment Action="X" Type="XF" b1="ADAMS_KU" b2="138 KV" b3="XF188" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68770</SeqNum>
    <Name>138/69.Algonquin.T1812+L138.Algonquin-Dixie</Name>
    <LastEdit Timestamp="2024-07-09T12:27:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALGONQU3" b2="138 KV" b3="138KVTR5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALGONQU3" b2="69 KV" b3="69KVTR52" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALGONQU3" b2="138 KV" b3="ALG-DIXI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALGONQU3" b2="69 KV" b3="TR5EMXF2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALGONQU3" b2="138 KV" b3="XF1812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DIXI_LGE" b2="138 KV" b3="BDX_3812" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68780</SeqNum>
    <Name>L161.LivingstonCo-SouthPaducah</Name>
    <LastEdit Timestamp="2024-07-09T14:37:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIVINGS2" b2="161 KV" b3="B131_804" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LIVINGS2" b2="161 KV" b3="B131_807" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIVINGS2" b2="161 KV" b3="SPD-LIVI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="S_PDUCAH" b2="161 KV" b3="B097_824" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="S_PDUCAH" b2="161 KV" b3="B097_827" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68790</SeqNum>
    <Name>138/69.AmericanAve.T186</Name>
    <LastEdit Timestamp="2024-07-09T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMERICAN" b2="69 KV" b3="B196_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMERICAN" b2="138 KV" b3="B196_703" />
      <ContingencyEquipment Action="X" Type="XF" b1="AMERICAN" b2="138 KV" b3="XF186" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68800</SeqNum>
    <Name>L161.LivingstonCo-NoPrinceton</Name>
    <LastEdit Timestamp="2024-07-09T14:33:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIVINGS2" b2="161 KV" b3="B131_834" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LIVINGS2" b2="161 KV" b3="B131_837" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIVINGS2" b2="161 KV" b3="LIV-NPR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_PRNCTN" b2="161 KV" b3="CB802" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_PRNCTN" b2="161 KV" b3="CB804" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68810</SeqNum>
    <Name>L138.Rodburn-GoddardL-FlemingB-Wedonia-KentonLG</Name>
    <LastEdit Timestamp="2024-07-09T13:29:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FLEMINGB" b2="138 KV" b3="FLE-FLEM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLEMINGS" b2="138 KV" b3="LD_153" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLEMINGB" b2="138 KV" b3="GOD-FLEM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTN_LG" b2="138 KV" b3="B091_724" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTN_LG" b2="138 KV" b3="B091_727" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RODBURN" b2="138 KV" b3="B090_724" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RODBURN" b2="138 KV" b3="B090_727" />
      <ContingencyEquipment Action="L" Type="LN" b1="GODDARDL" b2="138 KV" b3="ROD-GODD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WEDONIA" b2="138 KV" b3="LD_155" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLEMINGB" b2="138 KV" b3="WED-FLEM" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENTN_LG" b2="138 KV" b3="WED-KENT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68820</SeqNum>
    <Name>161/69.Artemus.T184</Name>
    <LastEdit Timestamp="2024-07-09T14:53:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARTEMUSS" b2="69 KV" b3="B218_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARTEMUSS" b2="161 KV" b3="B218_803" />
      <ContingencyEquipment Action="X" Type="XF" b1="ARTEMUSS" b2="161 KV" b3="XF184" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68830</SeqNum>
    <Name>L161.LivingstonCo-KyHydro</Name>
    <LastEdit Timestamp="2024-07-09T14:31:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="KY_HYDRO" b2="161 KV" b3="825" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KY_HYDRO" b2="161 KV" b3="828" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIVINGS2" b2="161 KV" b3="12L-5KY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIVINGS2" b2="161 KV" b3="B131_824" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LIVINGS2" b2="161 KV" b3="B131_827" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68840</SeqNum>
    <Name>138/69.Ashbottom.T1814</Name>
    <LastEdit Timestamp="2024-07-09T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHBT_LG" b2="69 KV" b3="B69KVTR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHBT_LG" b2="69 KV" b3="TR1EMXF1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHBT_LG" b2="138 KV" b3="TR1_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHBT_LG" b2="138 KV" b3="TR1_4" />
      <ContingencyEquipment Action="X" Type="XF" b1="ASHBT_LG" b2="138 KV" b3="XF1814" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68850</SeqNum>
    <Name>L161.LivingstonCo-Calvrtva</Name>
    <LastEdit Timestamp="2024-07-09T14:19:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CALVRTVA" b2="161 KV" b3="815" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVRTVA" b2="161 KV" b3="818" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIVINGS2" b2="161 KV" b3="12L-5CA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIVINGS2" b2="161 KV" b3="B131_814" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LIVINGS2" b2="161 KV" b3="B131_817" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68860</SeqNum>
    <Name>138/69.Ashbottom.T1819</Name>
    <LastEdit Timestamp="2024-07-09T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHBT_LG" b2="69 KV" b3="B69KVTR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHBT_LG" b2="138 KV" b3="TR2_6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHBT_LG" b2="138 KV" b3="TR2_8" />
      <ContingencyEquipment Action="X" Type="XF" b1="ASHBT_LG" b2="138 KV" b3="XF1819" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68870</SeqNum>
    <Name>138/69.DanvilleNorth.T184+L138.DanvllNrth-MercerC</Name>
    <LastEdit Timestamp="2024-07-09T12:29:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DANVL_KU" b2="69 KV" b3="B204_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANVL_KU" b2="138 KV" b3="B204_703" />
      <ContingencyEquipment Action="L" Type="LN" b1="DANVL_KU" b2="138 KV" b3="MER-DANV" />
      <ContingencyEquipment Action="X" Type="XF" b1="DANVL_KU" b2="138 KV" b3="XF184" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCER_C" b2="138 KV" b3="B204_725" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68880</SeqNum>
    <Name>L138.LakeReba-4BgadTap-LakeReba163</Name>
    <LastEdit Timestamp="2025-01-31T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="4BGADTAP" b2="138 KV" b3="BGARMYDP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKE_REA" b2="69 KV" b3="B163_658" />
      <ContingencyEquipment Action="L" Type="LN" b1="4BGADTAP" b2="138 KV" b3="BGA_LAK2" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKE_REA" b2="138 KV" b3="XF151" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKE_REB" b2="138 KV" b3="B162_714" />
      <ContingencyEquipment Action="L" Type="LN" b1="4BGADTAP" b2="138 KV" b3="BGA_LAKE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68890</SeqNum>
    <Name>L161.Earlington-RiverQueen-GreenRiver</Name>
    <LastEdit Timestamp="2024-07-09T14:00:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLINGT" b2="161 KV" b3="B202_804" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EARLINGT" b2="161 KV" b3="B202_807" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="161 KV" b3="B009_864" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="161 KV" b3="B009_872" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVER_Q" b2="69 KV" b3="CB638" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIVER_Q" b2="161 KV" b3="XF" />
      <ContingencyEquipment Action="L" Type="LN" b1="EARLINGT" b2="161 KV" b3="RIV-EARL" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRN_RV_P" b2="161 KV" b3="RIV-GRN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIVER_Q" b2="161 KV" b3="RVR-RVRQ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68900</SeqNum>
    <Name>L161.LakeReb-WstIrvine-Dlvnta+161/138.LakeReb.T154</Name>
    <LastEdit Timestamp="2024-07-10T16:21:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELVINTA" b2="161 KV" b3="B139_804" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELVINTA" b2="161 KV" b3="B139_807" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELVINTA" b2="161 KV" b3="WIR-DELV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKE_REB" b2="138 KV" b3="B162_708" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKE_REB" b2="161 KV" b3="B162_804" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKE_REB" b2="161 KV" b3="WIR-LAKE" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKE_REB" b2="161 KV" b3="XF154" />
      <ContingencyEquipment Action="L" Type="LN" b1="W_IRVN2" b2="161 KV" b3="WIR2-WIR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_IRVNE" b2="161 KV" b3="B193_803" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68920</SeqNum>
    <Name>161/69.Dorchester.T1814</Name>
    <LastEdit Timestamp="2024-07-09T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DORCHEST" b2="69 KV" b3="B072_628" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DORCHEST" b2="161 KV" b3="B072_828" />
      <ContingencyEquipment Action="X" Type="XF" b1="DORCHEST" b2="161 KV" b3="XF1814" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68930</SeqNum>
    <Name>161/69.Dorchester.T1815</Name>
    <LastEdit Timestamp="2024-07-09T11:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DORCHEST" b2="69 KV" b3="B072_638" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DORCHEST" b2="161 KV" b3="B072_838" />
      <ContingencyEquipment Action="X" Type="XF" b1="DORCHEST" b2="161 KV" b3="XF1815" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68940</SeqNum>
    <Name>161/69.Earlington.T16</Name>
    <LastEdit Timestamp="2024-07-10T09:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLINGT" b2="69 KV" b3="B202_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLINGT" b2="161 KV" b3="B202_808" />
      <ContingencyEquipment Action="X" Type="XF" b1="EARLINGT" b2="161 KV" b3="XF16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68950</SeqNum>
    <Name>161/69.Elihu.T187&amp;T189+L161.Elhu-Coopr+Elhu-Alclde</Name>
    <LastEdit Timestamp="2024-07-10T16:29:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ALCALDE" b2="161 KV" b3="807" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALCALDE" b2="161 KV" b3="B194_804" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOP_EK" b2="161 KV" b3="CB1044" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COOP_EK" b2="161 KV" b3="SW1047" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIHU" b2="69 KV" b3="CB96_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIHU" b2="69 KV" b3="CB96_618" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIHU" b2="161 KV" b3="CB96_804" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIHU" b2="161 KV" b3="CB96_814" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOP_EK" b2="161 KV" b3="COO-ELIH" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCALDE" b2="161 KV" b3="ELI-ALCA" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELIHU" b2="161 KV" b3="XF187" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELIHU" b2="161 KV" b3="XF189" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68960</SeqNum>
    <Name>L138.TipTop-PondCreek-KnobCreek</Name>
    <LastEdit Timestamp="2024-07-10T16:14:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOB_CRE" b2="138 KV" b3="CBKC_856" />
      <ContingencyEquipment Action="L" Type="LN" b1="KNOB_CRE" b2="138 KV" b3="KNO-POND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POND_CRE" b2="138 KV" b3="CB856_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIP_TOP" b2="138 KV" b3="BTT_3856" />
      <ContingencyEquipment Action="L" Type="LN" b1="POND_CRE" b2="138 KV" b3="TIP-POND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIP_TOP" b2="138 KV" b3="TT_3856E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68970</SeqNum>
    <Name>138/69.Elizbthtwn.T186+L138.Etwn-Hardnc+Etwn-Nelsn</Name>
    <LastEdit Timestamp="2024-07-11T07:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZABET" b2="69 KV" b3="B034_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZABET" b2="138 KV" b3="B034_704" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZABET" b2="138 KV" b3="B034_714" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIZABET" b2="138 KV" b3="HAR-ELI7" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIZABET" b2="138 KV" b3="NEL-ELIZ" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELIZABET" b2="138 KV" b3="XF186" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68980</SeqNum>
    <Name>138/69.EastFrankfort.T1813</Name>
    <LastEdit Timestamp="2024-07-10T09:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="E_FRKFRT" b2="69 KV" b3="B136_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E_FRKFRT" b2="138 KV" b3="B136_708" />
      <ContingencyEquipment Action="X" Type="XF" b1="E_FRKFRT" b2="138 KV" b3="XF1813" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>68990</SeqNum>
    <Name>138/69.EastFrankfort.T1814</Name>
    <LastEdit Timestamp="2024-07-10T09:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="E_FRKFRT" b2="69 KV" b3="B136_618" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E_FRKFRT" b2="138 KV" b3="B136_718" />
      <ContingencyEquipment Action="X" Type="XF" b1="E_FRKFRT" b2="138 KV" b3="XF1814" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69000</SeqNum>
    <Name>161/69.Farley.T189</Name>
    <LastEdit Timestamp="2024-07-10T16:04:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARLEY2" b2="69 KV" b3="B128_628" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARLEY2" b2="161 KV" b3="B128_804" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARLEY2" b2="161 KV" b3="B128_814" />
      <ContingencyEquipment Action="X" Type="XF" b1="FARLEY2" b2="161 KV" b3="XF189" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69010</SeqNum>
    <Name>138/69.Farmers.T185+L138.Farmers-Farmerstp</Name>
    <LastEdit Timestamp="2024-07-11T07:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMERS2" b2="69 KV" b3="B175_618" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMERS2" b2="138 KV" b3="B175_703" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMERS2" b2="138 KV" b3="FAR-FARM" />
      <ContingencyEquipment Action="X" Type="XF" b1="FARMERS2" b2="138 KV" b3="XF185" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69030</SeqNum>
    <Name>138/69.Fawkes.T1816</Name>
    <LastEdit Timestamp="2024-07-10T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKESLG" b2="69 KV" b3="B102_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKESLG" b2="138 KV" b3="B102_708" />
      <ContingencyEquipment Action="X" Type="XF" b1="FAWKESLG" b2="138 KV" b3="XF1816" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69040</SeqNum>
    <Name>138/69.Fawkes.T1813</Name>
    <LastEdit Timestamp="2024-07-10T09:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKESLG" b2="69 KV" b3="B102_638" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKESLG" b2="138 KV" b3="B102_718" />
      <ContingencyEquipment Action="X" Type="XF" b1="FAWKESLG" b2="138 KV" b3="XF1813" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69050</SeqNum>
    <Name>345/138.Ghent.T1517 (LGEE)</Name>
    <LastEdit Timestamp="2025-07-08T10:17:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="138 KV" b3="B165_708" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_903" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_904" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_926" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_936" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_946" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_964" />
      <ContingencyEquipment Action="X" Type="XF" b1="GHENT_LG" b2="345 KV" b3="XF1517" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69060</SeqNum>
    <Name>345/138.Ghent.T1529 (LGEE)</Name>
    <LastEdit Timestamp="2025-07-08T10:29:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="138 KV" b3="B165_718" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_913" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_914" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_924" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_934" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_944" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_954" />
      <ContingencyEquipment Action="X" Type="XF" b1="GHENT_LG" b2="345 KV" b3="XF1529" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69070</SeqNum>
    <Name>161/69.Grahamville.T188+L69.Forrestdale</Name>
    <LastEdit Timestamp="2026-04-02T12:43:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAHAMVI" b2="69 KV" b3="B161_624" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAHAMVI" b2="161 KV" b3="B161_804" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAHAMVI" b2="161 KV" b3="CB802" />
      <ContingencyEquipment Action="L" Type="LN" b1="FORRESTD" b2="69 KV" b3="GRA-FORR" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRAHAMVI" b2="161 KV" b3="XF188" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69080</SeqNum>
    <Name>138/69.GreenRiverSteel.T10</Name>
    <LastEdit Timestamp="2024-07-12T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREEN_RL" b2="69 KV" b3="B100_618" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREEN_RL" b2="138 KV" b3="B100_718" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREEN_RL" b2="138 KV" b3="XF10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69090</SeqNum>
    <Name>161/138.GreenRiverPlaza.T1</Name>
    <LastEdit Timestamp="2024-07-12T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="138 KV" b3="B009_778" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="161 KV" b3="B009_878" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="161 KV" b3="B009_888" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRN_RV_P" b2="161 KV" b3="XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69100</SeqNum>
    <Name>161/138.GreenRiverPlaza.T2</Name>
    <LastEdit Timestamp="2024-07-12T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="138 KV" b3="B009_768" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GRN_RV_P" b2="138 KV" b3="B009_769" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="161 KV" b3="B009_868" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="161 KV" b3="B009_878" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRN_RV_P" b2="161 KV" b3="XF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69110</SeqNum>
    <Name>161/138.GreenRiverPlaza.T3</Name>
    <LastEdit Timestamp="2024-07-12T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="138 KV" b3="B009_788" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="161 KV" b3="B009_884" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="161 KV" b3="B009_888" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRN_RV_P" b2="161 KV" b3="XF3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69120</SeqNum>
    <Name>138/69.GreenRiverPlaza.T1828</Name>
    <LastEdit Timestamp="2024-07-12T10:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="69 KV" b3="B009_668" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="138 KV" b3="B009_708" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRN_RV_P" b2="138 KV" b3="XF1828" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69130</SeqNum>
    <Name>138/69.GreenRiverPlaza.T1827</Name>
    <LastEdit Timestamp="2024-07-12T10:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="69 KV" b3="B009_678" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRN_RV_P" b2="138 KV" b3="B009_758" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRN_RV_P" b2="138 KV" b3="XF1827" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69140</SeqNum>
    <Name>138/69.Haefling.T1813</Name>
    <LastEdit Timestamp="2024-07-15T13:02:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAEFLING" b2="69 KV" b3="B127_638" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAEFLING" b2="138 KV" b3="B127_708" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAEFLING" b2="138 KV" b3="XF1813" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69150</SeqNum>
    <Name>138/69.Hancock4.T186</Name>
    <LastEdit Timestamp="2024-07-15T13:18:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK4" b2="138 KV" b3="HN138KVT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK4" b2="69 KV" b3="HN6645TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="HANCOCK4" b2="138 KV" b3="XF186" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69160</SeqNum>
    <Name>345/138.HardinCounty.T2</Name>
    <LastEdit Timestamp="2025-08-19T10:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="138 KV" b3="738" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="345 KV" b3="CB908" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARDIN_C" b2="345 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69170</SeqNum>
    <Name>138/69.HardinCounty.T1</Name>
    <LastEdit Timestamp="2025-08-19T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="69 KV" b3="B178_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="138 KV" b3="CB702" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="138 KV" b3="CB708" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARDIN_C" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69180</SeqNum>
    <Name>161/69.HarlanWye.T1812</Name>
    <LastEdit Timestamp="2024-07-12T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARLAN_W" b2="69 KV" b3="B032_648" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARLAN_W" b2="161 KV" b3="B032_848" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARLAN_W" b2="161 KV" b3="XF1812" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69190</SeqNum>
    <Name>138/69.HigbyMill.T1814</Name>
    <LastEdit Timestamp="2024-07-12T11:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGBY_MI" b2="69 KV" b3="B066_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGBY_MI" b2="138 KV" b3="B066_708" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIGBY_MI" b2="138 KV" b3="XF1814" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69200</SeqNum>
    <Name>138/69.HigbyMill.T1815</Name>
    <LastEdit Timestamp="2024-07-12T11:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGBY_MI" b2="69 KV" b3="B066_618" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGBY_MI" b2="138 KV" b3="B066_718" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIGBY_MI" b2="138 KV" b3="XF1815" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69210</SeqNum>
    <Name>138/69.HigbyMill.T3</Name>
    <LastEdit Timestamp="2024-07-12T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGBY_MI" b2="69 KV" b3="CB638" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGBY_MI" b2="138 KV" b3="CB728" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIGBY_MI" b2="138 KV" b3="XF3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69220</SeqNum>
    <Name>161/138.Imboden.T187</Name>
    <LastEdit Timestamp="2024-07-12T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IMBODEN" b2="69 KV" b3="B071_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IMBODEN" b2="161 KV" b3="B071_803" />
      <ContingencyEquipment Action="X" Type="XF" b1="IMBODEN" b2="161 KV" b3="XF187" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69230</SeqNum>
    <Name>138/69.Kenton.T1814</Name>
    <LastEdit Timestamp="2024-07-12T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTN_LG" b2="69 KV" b3="B091_688" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTN_LG" b2="138 KV" b3="B091_708" />
      <ContingencyEquipment Action="X" Type="XF" b1="KENTN_LG" b2="138 KV" b3="XF1814" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69240</SeqNum>
    <Name>138/69.Kenton.T1815</Name>
    <LastEdit Timestamp="2024-07-12T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTN_LG" b2="69 KV" b3="B091_698" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTN_LG" b2="138 KV" b3="B091_718" />
      <ContingencyEquipment Action="X" Type="XF" b1="KENTN_LG" b2="138 KV" b3="XF1815" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69250</SeqNum>
    <Name>L500.Pocket-Pineville+500/345.Pineville.T127</Name>
    <LastEdit Timestamp="2024-07-12T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEVIL" b2="345 KV" b3="B192_944" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEVIL" b2="345 KV" b3="B192_952" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINEVIL" b2="500 KV" b3="POC-PINE" />
      <ContingencyEquipment Action="X" Type="XF" b1="PINEVIL" b2="500 KV" b3="XF127" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCKET_N" b2="500 KV" b3="203_5014" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCKET_N" b2="500 KV" b3="203_5034" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69260</SeqNum>
    <Name>345/161.Pineville.T1411</Name>
    <LastEdit Timestamp="2024-07-15T13:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEVIL" b2="161 KV" b3="B192_808" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEVIL" b2="161 KV" b3="B192_818" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEVIL" b2="345 KV" b3="B192_903" />
      <ContingencyEquipment Action="X" Type="XF" b1="PINEVIL" b2="345 KV" b3="XF1411" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69270</SeqNum>
    <Name>500/161.PocketNorth.T147</Name>
    <LastEdit Timestamp="2024-07-12T13:47:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POCKET_N" b2="500 KV" b3="203_5003" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCKET_N" b2="161 KV" b3="B203_818" />
      <ContingencyEquipment Action="X" Type="XF" b1="POCKET_N" b2="500 KV" b3="XF147" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69280</SeqNum>
    <Name>345/138.NAS.T1+L345.Ghent-NAS</Name>
    <LastEdit Timestamp="2024-07-12T10:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_954" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_964" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAS9947" b2="138 KV" b3="CB718" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAS9947" b2="345 KV" b3="CB914" />
      <ContingencyEquipment Action="X" Type="XF" b1="NAS9947" b2="345 KV" b3="XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69290</SeqNum>
    <Name>345/138.PddysW.T155</Name>
    <LastEdit Timestamp="2024-07-12T13:42:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PADDYS_W" b2="138 KV" b3="3802_TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADDYS_W" b2="138 KV" b3="3828_TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADDYS_W" b2="345 KV" b3="4533_TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADDYS_W" b2="345 KV" b3="4535_TR1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PADDYS_W" b2="345 KV" b3="XF155" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69310</SeqNum>
    <Name>L161.Alcalde-Farley</Name>
    <LastEdit Timestamp="2024-07-12T14:03:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ALCALDE" b2="161 KV" b3="817" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALCALDE" b2="161 KV" b3="B194_814" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCALDE" b2="161 KV" b3="FAR-ALCA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARLEY2" b2="161 KV" b3="B128_804" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARLEY2" b2="161 KV" b3="B128_807" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69320</SeqNum>
    <Name>345/138.BrownNorth.XF157</Name>
    <LastEdit Timestamp="2025-12-16T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_NO" b2="138 KV" b3="B152_718" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_NO" b2="345 KV" b3="B152_903" />
      <ContingencyEquipment Action="X" Type="XF" b1="BROWN_NO" b2="345 KV" b3="XF157" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69330</SeqNum>
    <Name>345/138.WLxngtn.T156+L345.Ghent-WLxngtn-Brwn_N</Name>
    <LastEdit Timestamp="2025-07-22T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_NO" b2="345 KV" b3="B152_912" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_NO" b2="345 KV" b3="CB914" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_912" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_914" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_LXNGT" b2="138 KV" b3="B154_708" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROWN_NO" b2="345 KV" b3="BRO-WLX" />
      <ContingencyEquipment Action="L" Type="LN" b1="GHENT_LG" b2="345 KV" b3="WLE-GHEN" />
      <ContingencyEquipment Action="X" Type="XF" b1="W_LXNGT" b2="345 KV" b3="XF156" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69340</SeqNum>
    <Name>L345.Ghent-WFrankfort+345/138.WFrankfort.T154</Name>
    <LastEdit Timestamp="2024-07-12T11:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_922" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_924" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_FNKFT" b2="138 KV" b3="B211_708" />
      <ContingencyEquipment Action="L" Type="LN" b1="GHENT_LG" b2="345 KV" b3="WFR-GHEN" />
      <ContingencyEquipment Action="X" Type="XF" b1="W_FNKFT" b2="345 KV" b3="XF154" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69360</SeqNum>
    <Name>L345.BlueLick-MillCreek</Name>
    <LastEdit Timestamp="2025-10-29T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUE_LCK" b2="345 KV" b3="4532_38T" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUE_LCK" b2="345 KV" b3="MIL-BLUE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUE_LCK" b2="345 KV" b3="TR24532T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="4502_32T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="BMC_4532" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69370</SeqNum>
    <Name>L345.BlueLick-Middletown</Name>
    <LastEdit Timestamp="2024-07-15T13:50:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUE_LCK" b2="345 KV" b3="4532_38T" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUE_LCK" b2="345 KV" b3="MID-BLUE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUE_LCK" b2="345 KV" b3="TR14538T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="345 KV" b3="4538_TR5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="345 KV" b3="BMT_4538" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69380</SeqNum>
    <Name>345/138.Middletown.T1522</Name>
    <LastEdit Timestamp="2024-07-12T13:30:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="138 KV" b3="138KVTR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="345 KV" b3="345_TR3A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="138 KV" b3="BTR2EMXF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="345 KV" b3="TR3ATRAN" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDLT_LG" b2="345 KV" b3="XF1522" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69390</SeqNum>
    <Name>345/138.Middletown.T5</Name>
    <LastEdit Timestamp="2024-07-12T10:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="138 KV" b3="138KVTR5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="345 KV" b3="345KVTR5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="345 KV" b3="4538_TR5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="138 KV" b3="TR5_6" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDLT_LG" b2="345 KV" b3="XF1510" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69400</SeqNum>
    <Name>345/138.Middletown.T1521</Name>
    <LastEdit Timestamp="2024-07-15T13:25:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="138 KV" b3="138KVTR4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="345 KV" b3="TR4ATRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="345 KV" b3="TR4BTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="138 KV" b3="TR4_TIE" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDLT_LG" b2="345 KV" b3="XF1521" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69410</SeqNum>
    <Name>L115.Bedford-OsterburgEast-Claysburg</Name>
    <LastEdit Timestamp="2024-07-12T13:49:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD" b2="115 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD" b2="115 KV" b3="B44" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEDFORD" b2="115 KV" b3="BED-OSTE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSBUR" b2="115 KV" b3="B45" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSBUR" b2="115 KV" b3="B46" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYSBUR" b2="115 KV" b3="CLA-OST" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OSTERBUR" b2="115 KV" b3="1 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69420</SeqNum>
    <Name>L345.BrownNorth-GlendaleSouth</Name>
    <LastEdit Timestamp="2025-12-16T12:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_NO" b2="345 KV" b3="B152_932" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_NO" b2="345 KV" b3="B152_934" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROWN_NO" b2="345 KV" b3="BRO-GLEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDALS" b2="345 KV" b3="922" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDALS" b2="345 KV" b3="924" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69430</SeqNum>
    <Name>L345.BrownNorth-WestGarrard</Name>
    <LastEdit Timestamp="2024-07-15T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROWN_NO" b2="345 KV" b3="BRO-WGAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_NO" b2="345 KV" b3="CB944" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_NO" b2="345 KV" b3="CB954" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_GARARD" b2="345 KV" b3="CB904" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_GARARD" b2="345 KV" b3="CB912" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69440</SeqNum>
    <Name>L345.Buckner-Middletown</Name>
    <LastEdit Timestamp="2024-07-15T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKNER" b2="345 KV" b3="4543_44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKNER" b2="345 KV" b3="BBU_4550" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKNER" b2="345 KV" b3="MID-BUCK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="345 KV" b3="4531_43T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="345 KV" b3="BMT_4543" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69450</SeqNum>
    <Name>L345.Buckner-TrimbleCounty</Name>
    <LastEdit Timestamp="2024-07-15T13:54:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKNER" b2="345 KV" b3="4543_44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKNER" b2="345 KV" b3="BBU_4551" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKNER" b2="345 KV" b3="BUC-TRMB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="4516_44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="TC_4544" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69460</SeqNum>
    <Name>345/138.MillCreek.T6345</Name>
    <LastEdit Timestamp="2024-07-15T14:37:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="138 KV" b3="138KVTR6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="14 KV" b3="14KVTR6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="BMC_4531" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="BMC_4532" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="BMC_4533" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="CB4560" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILL_CRE" b2="14 KV" b3="LD_264" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MILL_CRE" b2="345 KV" b3="TR5_TR6T" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILL_CRE" b2="138 KV" b3="TR6138" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILL_CRE" b2="14 KV" b3="TR614" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILL_CRE" b2="345 KV" b3="TR6345" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MILL_CRE" b2="138 KV" b3="TR6X" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69470</SeqNum>
    <Name>L345.DaviesCo-Smith</Name>
    <LastEdit Timestamp="2024-07-15T11:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIESCO" b2="345 KV" b3="CB902" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIESCO" b2="345 KV" b3="CB904" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAVIESCO" b2="345 KV" b3="DAV-SMI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITH" b2="345 KV" b3="834" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITH" b2="345 KV" b3="836" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69480</SeqNum>
    <Name>L345.DaviesCo-Hardin</Name>
    <LastEdit Timestamp="2024-07-15T11:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIESCO" b2="345 KV" b3="CB904" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIESCO" b2="345 KV" b3="CB912" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAVIESCO" b2="345 KV" b3="HAR-DAVI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="345 KV" b3="CB924" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="345 KV" b3="CB934" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69490</SeqNum>
    <Name>345/138.MillCreek.T5345</Name>
    <LastEdit Timestamp="2025-05-28T13:45:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="138 KV" b3="138KVTR5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="BMC_4501" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="BMC_4502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="BMC_4503" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="BMC_4504" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILL_CRE" b2="14 KV" b3="LD_262" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILL_CRE" b2="138 KV" b3="TR5138" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILL_CRE" b2="14 KV" b3="TR514" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILL_CRE" b2="345 KV" b3="TR5345" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MILL_CRE" b2="138 KV" b3="TR5X" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MILL_CRE" b2="345 KV" b3="TR5_TR6T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69500</SeqNum>
    <Name>345/138.Northside.T153</Name>
    <LastEdit Timestamp="2024-07-16T12:03:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="N_SIDE" b2="138 KV" b3="138KVTR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_SIDE" b2="345 KV" b3="345KVTR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_SIDE" b2="138 KV" b3="TR1EMXF6" />
      <ContingencyEquipment Action="X" Type="XF" b1="N_SIDE" b2="345 KV" b3="XF153" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69510</SeqNum>
    <Name>L138.AmericanAve-Reynolds</Name>
    <LastEdit Timestamp="2025-01-17T15:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMERICAN" b2="138 KV" b3="B196_704" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMERICAN" b2="138 KV" b3="B196_707" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMERICAN" b2="138 KV" b3="REY-AMER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNLDS" b2="138 KV" b3="CB702" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="REYNLDS" b2="138 KV" b3="SW703" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69520</SeqNum>
    <Name>L138.AmericanAve-Haefling</Name>
    <LastEdit Timestamp="2024-07-15T13:44:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMERICAN" b2="138 KV" b3="B196_714" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMERICAN" b2="138 KV" b3="B196_717" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMERICAN" b2="138 KV" b3="HAE-AMER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAEFLING" b2="138 KV" b3="B127_764" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAEFLING" b2="138 KV" b3="B127_767" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69530</SeqNum>
    <Name>L138.Ghent-WhiteSU</Name>
    <LastEdit Timestamp="2025-07-28T11:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="4WHITESU" b2="138 KV" b3="702" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4WHITESU" b2="138 KV" b3="714" />
      <ContingencyEquipment Action="L" Type="LN" b1="4WHITESU" b2="138 KV" b3="4WH-GHEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="138 KV" b3="B165_754" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69540</SeqNum>
    <Name>L138.Ghent-BlackwellTap</Name>
    <LastEdit Timestamp="2024-07-15T13:46:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLKWLLG" b2="138 KV" b3="CB_704" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLKWLLG" b2="138 KV" b3="CB_708" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="138 KV" b3="722" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="138 KV" b3="B165_764" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLKWLLG" b2="138 KV" b3="GHE-BLKW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69550</SeqNum>
    <Name>L138.Ghent-Fairview</Name>
    <LastEdit Timestamp="2024-07-15T13:48:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08FAIRVW" b2="138 KV" b3="55-B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08FAIRVW" b2="138 KV" b3="58-55" />
      <ContingencyEquipment Action="L" Type="LN" b1="08FAIRVW" b2="138 KV" b3="08F-GHE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="138 KV" b3="B165_774" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69560</SeqNum>
    <Name>L230.Bergenfield-NewMilford.O-2293</Name>
    <LastEdit Timestamp="2025-09-16T10:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BERGENFI" b2="230 KV" b3="BER-NEWO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGENFI" b2="230 KV" b3="O-2293M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWMILFR" b2="230 KV" b3="2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWMILFR" b2="230 KV" b3="9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69570</SeqNum>
    <Name>L230.Bergenfield-Leonia.P-2294</Name>
    <LastEdit Timestamp="2025-09-16T10:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BERGENFI" b2="230 KV" b3="BER-LEOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGENFI" b2="230 KV" b3="P-2294" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEONIA" b2="230 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEONIA" b2="230 KV" b3="SECT 2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69600</SeqNum>
    <Name>L138.TwinBranch-BeechRoad-CountyRoad</Name>
    <LastEdit Timestamp="2024-07-15T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEECHROA" b2="138 KV" b3="BEE-TWI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEECHROA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COUNTYRD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEECHROA" b2="138 KV" b3="BEE-COU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COUNTYRD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="E2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69610</SeqNum>
    <Name>230/13.Penrose.T1</Name>
    <LastEdit Timestamp="2024-07-15T11:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PENROSE" b2="230 KV" b3="1TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENROSE" b2="13 KV" b3="1TRLS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENROSE" b2="230 KV" b3="745" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENROSE" b2="230 KV" b3="785" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69620</SeqNum>
    <Name>230/13.Penrose.T3</Name>
    <LastEdit Timestamp="2024-07-15T11:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PENROSE" b2="230 KV" b3="3TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENROSE" b2="13 KV" b3="3TRLS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENROSE" b2="230 KV" b3="895" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENROSE" b2="230 KV" b3="905" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69680</SeqNum>
    <Name>L138.Shoreline-TrailCreek</Name>
    <LastEdit Timestamp="2025-11-14T09:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHORELIN" b2="138 KV" b3="14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHORELIN" b2="138 KV" b3="14-120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRAILCRE" b2="138 KV" b3="14" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHORELIN" b2="138 KV" b3="SHO-TRAI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69690</SeqNum>
    <Name>L138.Springdale-All4Jct-All4Tap-All6-Brackenridge</Name>
    <LastEdit Timestamp="2024-05-23T04:29:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLDAM6" b2="138 KV" b3="ALUD4JCT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLELUD4" b2="138 KV" b3="T4E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLELUD4" b2="138 KV" b3="T4W" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLLUD4J" b2="138 KV" b3="ALJ-ALL" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLLUD4J" b2="138 KV" b3="ALJ-SPR" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLLUD4J" b2="138 KV" b3="ALJ-ALT" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLLUD4T" b2="138 KV" b3="ALT-ALU" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLLUD4T" b2="138 KV" b3="ALT-BRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRACKENR" b2="138 KV" b3="ALUD4TAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="B11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69700</SeqNum>
    <Name>L138.Knox-EastAkron</Name>
    <LastEdit Timestamp="2024-11-04T11:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EAKRON" b2="138 KV" b3="22" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EAKRON" b2="138 KV" b3="A128" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOX" b2="138 KV" b3="B81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOX" b2="138 KV" b3="B82" />
      <ContingencyEquipment Action="L" Type="LN" b1="KNOX" b2="138 KV" b3="EAK-KNO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69710</SeqNum>
    <Name>L138.Knox-Hagan</Name>
    <LastEdit Timestamp="2024-10-31T08:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAGAN" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAGAN" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOX" b2="138 KV" b3="B57" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOX" b2="138 KV" b3="B82" />
      <ContingencyEquipment Action="L" Type="LN" b1="KNOX" b2="138 KV" b3="HAGA-KNO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69780</SeqNum>
    <Name>L345.Lisle-Lockport.10802</Name>
    <LastEdit Timestamp="2025-11-21T12:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="103 LISL" b2="345 KV" b3="10802" />
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="345 KV" b3="L10802CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT4-5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69790</SeqNum>
    <Name>L345.Lockport-McCook.10803</Name>
    <LastEdit Timestamp="2026-04-16T13:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="51 MC CO" b2="345 KV" b3="10803" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT7-12CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="345 KV" b3="4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="345 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69800</SeqNum>
    <Name>L345.Lockport-McCook.10804</Name>
    <LastEdit Timestamp="2026-03-03T10:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="51 MC CO" b2="345 KV" b3="10804" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT1-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="345 KV" b3="12-13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="345 KV" b3="13-14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69840</SeqNum>
    <Name>345/138.Tollway.TR83</Name>
    <LastEdit Timestamp="2026-05-20T15:19:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="154 LIBE" b2="345 KV" b3="18502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="185 TOLL" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="185 TOLL" b2="345 KV" b3="BT5-6B6M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="185 TOLL" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="185 TOLL" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="185 TOLL" b2="138 KV" b3="TR83CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>69900</SeqNum>
    <Name>L138.Rochelle-Whittier</Name>
    <LastEdit Timestamp="2024-07-15T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCHELLE" b2="138 KV" b3="936" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCHELLE" b2="138 KV" b3="939" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCHELLE" b2="138 KV" b3="ROC-WHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITTIER" b2="138 KV" b3="984" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITTIER" b2="138 KV" b3="986" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70020</SeqNum>
    <Name>L230.NorthLebanon-Northkill</Name>
    <LastEdit Timestamp="2025-03-05T16:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEBNON" b2="230 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEBNON" b2="230 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHKILL" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHKILL" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="NRTHKILL" b2="230 KV" b3="NKI-NLE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70040</SeqNum>
    <Name>L115.Ox-Elmfarm-Sowego-Bristers.183</Name>
    <LastEdit Timestamp="2024-07-15T11:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRISTERS" b2="115 KV" b3="L2T183" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMFARM" b2="115 KV" b3="183F1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELMFARM" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELMFARM" b2="34.5 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOWEGODP" b2="115 KV" b3="183C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INDEPHIL" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="INDEPHIL" b2="115 KV" b3="183G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINDENDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMFARM" b2="115 KV" b3="183E1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINDENDP" b2="115 KV" b3="183F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MINVILDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="115 KV" b3="L3T183" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRISTERS" b2="115 KV" b3="183D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOWEGODP" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70050</SeqNum>
    <Name>230/115.Ox.TX3</Name>
    <LastEdit Timestamp="2024-07-16T12:00:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="230 KV" b3="H342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OX4" b2="115 KV" b3="L3T183" />
      <ContingencyEquipment Action="X" Type="XF" b1="OX4" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70060</SeqNum>
    <Name>230/115.Bristers.T2</Name>
    <LastEdit Timestamp="2024-07-15T13:20:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRISTERS" b2="230 KV" b3="H262" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRISTERS" b2="115 KV" b3="L2T183" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRISTERS" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70070</SeqNum>
    <Name>230/46.Raystown.TX1</Name>
    <LastEdit Timestamp="2024-12-26T15:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RAYSTOWN" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAYSTOWN" b2="46 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAYSTOWN" b2="230 KV" b3="B33" />
      <ContingencyEquipment Action="X" Type="XF" b1="RAYSTOWN" b2="230 KV" b3="NO1 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70090</SeqNum>
    <Name>L500.LadySmth-Chancelr.581</Name>
    <LastEdit Timestamp="2025-06-10T08:05:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHANCELR" b2="500 KV" b3="581" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHANCELR" b2="500 KV" b3="58192" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHANCELR" b2="500 KV" b3="H4T581" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMTH" b2="500 KV" b3="568T581" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMTH" b2="500 KV" b3="H1T581" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70100</SeqNum>
    <Name>500/115.Chancelr.T4</Name>
    <LastEdit Timestamp="2024-07-15T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CHANCELR" b2="500 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHANCELR" b2="500 KV" b3="H4T581" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHANCELR" b2="115 KV" b3="L492" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70110</SeqNum>
    <Name>L230.Brunner Island-West Shore</Name>
    <LastEdit Timestamp="2026-01-08T09:42:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNNERI" b2="230 KV" b3="BRU-WSHO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="WSHO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHORE" b2="230 KV" b3="BRIS_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHORE" b2="230 KV" b3="BRIS_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70130</SeqNum>
    <Name>138/69.Altavista.T2</Name>
    <LastEdit Timestamp="2024-07-16T11:55:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAVSTA" b2="69 KV" b3="3532" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAVSTA" b2="138 KV" b3="H232" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALTAVSTA" b2="138 KV" b3="TX_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70140</SeqNum>
    <Name>L138.Niles-SaltSprings.2</Name>
    <LastEdit Timestamp="2024-07-16T13:34:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="NILES" b2="138 KV" b3="A339" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NILES" b2="138 KV" b3="B336" />
      <ContingencyEquipment Action="L" Type="LN" b1="NILES" b2="138 KV" b3="NIL-SAL3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SALTSPRG" b2="138 KV" b3="A200" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTSPRG" b2="138 KV" b3="B197" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70150</SeqNum>
    <Name>L138.KewaneeEast-Bureau (Ameren)</Name>
    <LastEdit Timestamp="2025-03-18T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUREAU" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUREAU" b2="138 KV" b3="H7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEWANEE" b2="138 KV" b3="1552" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUREAU" b2="138 KV" b3="BUR-KEWA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70160</SeqNum>
    <Name>L230.Roseland-William.S-2297</Name>
    <LastEdit Timestamp="2024-07-16T12:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="1-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="1-13" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROSELAND" b2="230 KV" b3="ROS-WILS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLIAM1" b2="230 KV" b3="SC1-2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLIAM1" b2="230 KV" b3="SC1-4CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70170</SeqNum>
    <Name>230/138.Steele.AT22</Name>
    <LastEdit Timestamp="2024-07-16T12:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="230 KV" b3="256" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="230 KV" b3="257" />
      <ContingencyEquipment Action="X" Type="XF" b1="STEELE" b2="230 KV" b3="AT22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70180</SeqNum>
    <Name>L69.Harbeson-Sussex.6742</Name>
    <LastEdit Timestamp="2024-07-16T12:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBESON" b2="69 KV" b3="65" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBESON" b2="69 KV" b3="7130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBESON" b2="69 KV" b3="7150" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HARBESON" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARBESON" b2="69 KV" b3="HAR-SUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSSEX" b2="69 KV" b3="60" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70190</SeqNum>
    <Name>L69.Sussex-Pepper-Concord-Laurel.6722</Name>
    <LastEdit Timestamp="2025-05-15T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONCRDDP" b2="69 KV" b3="CONCRD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONCRDDP" b2="69 KV" b3="CONCRD1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONCRDDP" b2="69 KV" b3="MUMFORD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONCRDDP" b2="69 KV" b3="MUMFORD5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAURELDP" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONCRDDP" b2="69 KV" b3="CON-LAU" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONCRDDP" b2="69 KV" b3="CON-PEP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEPPER" b2="69 KV" b3="PEPPER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSSEX" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="L" Type="LN" b1="PEPPER" b2="69 KV" b3="PEP-SUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70200</SeqNum>
    <Name>L230.Loudoun-Arcola-NewRoad.2117</Name>
    <LastEdit Timestamp="2025-06-18T13:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARCOLA" b2="230 KV" b3="2117A" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWROAD" b2="230 KV" b3="2117B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ARCOLA" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="20302117" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="211752" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWROAD" b2="230 KV" b3="H1T2117" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70210</SeqNum>
    <Name>L230.Loudoun-Arcola-NewRoad.2123</Name>
    <LastEdit Timestamp="2025-06-18T13:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARCOLA" b2="230 KV" b3="2123A" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWROAD" b2="230 KV" b3="2123B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ARCOLA" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="21232173" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="212352" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWROAD" b2="230 KV" b3="H2T2123" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70220</SeqNum>
    <Name>230/115.NewRoad.TX1</Name>
    <LastEdit Timestamp="2024-07-16T11:58:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWROAD" b2="230 KV" b3="H1T2117" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWROAD" b2="115 KV" b3="L1T49" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWROAD" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70230</SeqNum>
    <Name>230/115.NewRoad.TX2</Name>
    <LastEdit Timestamp="2024-07-16T11:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWROAD" b2="230 KV" b3="H2T2123" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWROAD" b2="115 KV" b3="L2T113" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWROAD" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70240</SeqNum>
    <Name>L138.EllisonRoad-EngleRidge-McKinley</Name>
    <LastEdit Timestamp="2025-06-20T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELLISONR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELLISONR" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELLISONR" b2="138 KV" b3="ELL-ENG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ENGLERID" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENGLERID" b2="138 KV" b3="ENG-MCK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCKINLEY" b2="138 KV" b3="R" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70280</SeqNum>
    <Name>138/69.EastLima.T3</Name>
    <LastEdit Timestamp="2025-10-15T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="AA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMPBEL2" b2="138 KV" b3="CAM-ELI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELIMA" b2="138 KV" b3="T3 XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="69 KV" b3="U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="69 KV" b3="V" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70300</SeqNum>
    <Name>230/115.Poe.TX6</Name>
    <LastEdit Timestamp="2024-07-16T12:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POE" b2="230 KV" b3="H652" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POE" b2="115 KV" b3="L652" />
      <ContingencyEquipment Action="X" Type="XF" b1="POE" b2="230 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70320</SeqNum>
    <Name>L115.Suffolk-OakRidge-Ivor-BellAve.23</Name>
    <LastEdit Timestamp="2026-01-16T12:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELLAVE" b2="115 KV" b3="23D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLAVE" b2="115 KV" b3="23T1057_" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELLAVE" b2="115 KV" b3="4495" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IVOR" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="KINGSFRK" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSFRK" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKRIDGE" b2="115 KV" b3="23A" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKRIDGE" b2="115 KV" b3="23B" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKRIDGE" b2="115 KV" b3="23C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="OAKRIDGE" b2="13 KV" b3="SC1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="OAKRIDGE" b2="13 KV" b3="SC2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="OAKRIDGE" b2="115 KV" b3="SC3" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKRIDGE" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKRIDGE" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKRIDGE" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKRIDGE" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="115 KV" b3="23T44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="115 KV" b3="L2T23" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70330</SeqNum>
    <Name>L161.SummerShade(EKPC)-SummerShade(TVA)</Name>
    <LastEdit Timestamp="2025-04-30T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SUMSHADE" b2="161 KV" b3="20S-5SU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMER" b2="161 KV" b3="924" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMSHADE" b2="161 KV" b3="1024" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70360</SeqNum>
    <Name>L138.Glasgow-Mt.Pleasant.13844</Name>
    <LastEdit Timestamp="2024-07-16T12:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLASGOW" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLASGOW" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTPLEASN" b2="138 KV" b3="GLA-MTP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTPLEASN" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTPLEASN" b2="138 KV" b3="135" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70370</SeqNum>
    <Name>L69.Cedar-Motts.0795</Name>
    <LastEdit Timestamp="2024-10-23T09:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CEDAR" b2="69 KV" b3="CED-MOT4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTTS" b2="69 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70420</SeqNum>
    <Name>L138.Oakgrove-Waverly-WilliamsCrk</Name>
    <LastEdit Timestamp="2024-07-16T12:12:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKG APS" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKG APS" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKG APS" b2="138 KV" b3="OAK-WAV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAVERLY" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAVERLY" b2="138 KV" b3="WAV-WIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLMCRK" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILLMCRK" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70430</SeqNum>
    <Name>L138.502Junction-Osage.1</Name>
    <LastEdit Timestamp="2024-07-17T11:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="502JCT" b2="138 KV" b3="502-OSA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="138 KV" b3="B25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="138 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSAGE" b2="138 KV" b3="502JCT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70440</SeqNum>
    <Name>L138.502Junction-Osage.2</Name>
    <LastEdit Timestamp="2024-07-17T11:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="502JCT" b2="138 KV" b3="502-OSA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="138 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSAGE" b2="138 KV" b3="502JCT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70450</SeqNum>
    <Name>L138.502Junction-Whiteley.2</Name>
    <LastEdit Timestamp="2024-07-17T11:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="502JCT" b2="138 KV" b3="502-WHI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITELEY" b2="138 KV" b3="502JCT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70460</SeqNum>
    <Name>L138.502Junction-Whiteley.1</Name>
    <LastEdit Timestamp="2024-07-17T11:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="502JCT" b2="138 KV" b3="502-WHI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="138 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="138 KV" b3="B25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITELEY" b2="138 KV" b3="502JCT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70470</SeqNum>
    <Name>500/138.502Junction.T1</Name>
    <LastEdit Timestamp="2024-11-04T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="500 KV" b3="5L_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="500 KV" b3="5L_4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="500 KV" b3="5L_6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="500 KV" b3="5L_8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="138 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="502JCT" b2="138 KV" b3="B26" />
      <ContingencyEquipment Action="X" Type="XF" b1="502JCT" b2="500 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70480</SeqNum>
    <Name>230/35.Colora.TR1</Name>
    <LastEdit Timestamp="2025-04-23T16:25:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLORA" b2="230 KV" b3="235" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLORA" b2="230 KV" b3="236" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLORA" b2="35 KV" b3="30" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLORA" b2="230 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70490</SeqNum>
    <Name>230/35.Colora.TR2</Name>
    <LastEdit Timestamp="2025-04-23T16:27:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLORA" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLORA" b2="230 KV" b3="233" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLORA" b2="35 KV" b3="32" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLORA" b2="230 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70500</SeqNum>
    <Name>L345.Newton-CaseyWest (Ameren)</Name>
    <LastEdit Timestamp="2025-06-03T13:14:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CASEY  3" b2="345 KV" b3="3526" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CASEY  3" b2="345 KV" b3="3527" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWTON 3" b2="345 KV" b3="LN  2796" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTON 3" b2="345 KV" b3="3497" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTON 3" b2="345 KV" b3="3498" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70510</SeqNum>
    <Name>L345.Neoga-CaseyWest (Ameren)</Name>
    <LastEdit Timestamp="2025-06-03T13:14:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CASEY  3" b2="345 KV" b3="3526" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CASEY  3" b2="345 KV" b3="3529" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEOGA  3" b2="345 KV" b3="30309313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEOGA  3" b2="345 KV" b3="V5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEOGA  3" b2="345 KV" b3="V7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70520</SeqNum>
    <Name>L138.Hogan-Delaware</Name>
    <LastEdit Timestamp="2025-08-14T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELAWAIM" b2="138 KV" b3="U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOGAN" b2="138 KV" b3="DE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOGAN" b2="138 KV" b3="DE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELAWAIM" b2="138 KV" b3="DEL-HOG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70530</SeqNum>
    <Name>230/115.Staunton.TX6</Name>
    <LastEdit Timestamp="2024-07-17T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STAUNTON" b2="230 KV" b3="H672" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAUNTON" b2="115 KV" b3="L672" />
      <ContingencyEquipment Action="X" Type="XF" b1="STAUNTON" b2="230 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70540</SeqNum>
    <Name>NineMile.U1 (NYISO)</Name>
    <LastEdit Timestamp="2024-07-17T13:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NINMILNY" b2="345 KV" b3="DUMTB1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NINMILNY" b2="23 KV" b3="NINEMIL1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NINMILNY" b2="345 KV" b3="TB1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70550</SeqNum>
    <Name>Scriba.NineMile.U2</Name>
    <LastEdit Timestamp="2024-10-25T11:00:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="SCRIBA" b2="25 KV" b3="NINEMIL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCRIBA" b2="345 KV" b3="R230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCRIBA" b2="345 KV" b3="R925" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCRIBA" b2="345 KV" b3="TB2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70560</SeqNum>
    <Name>IndependenceUPNY.CC1&amp;2&amp;5</Name>
    <LastEdit Timestamp="2024-07-17T12:43:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="INDEPEND" b2="18 KV" b3="GT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="INDEPEND" b2="18 KV" b3="GT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDEPEND" b2="345 KV" b3="R250" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDEPEND" b2="345 KV" b3="R925" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INDEPEND" b2="18 KV" b3="SSA" />
      <ContingencyEquipment Action="U" Type="GEN" b1="INDEPEND" b2="18 KV" b3="ST5" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDEPEND" b2="345 KV" b3="TB1" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDEPEND" b2="345 KV" b3="TB2" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDEPEND" b2="345 KV" b3="TB5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70580</SeqNum>
    <Name>138/69.BlackRiver.T1</Name>
    <LastEdit Timestamp="2024-10-30T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BLACKRIV" b2="69 KV" b3="A41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="69 KV" b3="B12" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLACKRIV" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70620</SeqNum>
    <Name>138/69.BlackRiver.T2</Name>
    <LastEdit Timestamp="2024-10-30T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="9" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BLACKRIV" b2="69 KV" b3="A44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="69 KV" b3="B13" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLACKRIV" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70640</SeqNum>
    <Name>L138.Roanoke-Bennington-HuntingtonCourt</Name>
    <LastEdit Timestamp="2025-03-26T10:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENINGTN" b2="138 KV" b3="WVIRGINA" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENINGTN" b2="138 KV" b3="BEN-HUNT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTINCT" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENINGTN" b2="138 KV" b3="BEN-ROAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="138 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70670</SeqNum>
    <Name>345/115.ErieWest.T3</Name>
    <LastEdit Timestamp="2025-06-26T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="115 KV" b3="B133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="115 KV" b3="B136" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="345 KV" b3="B85" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="345 KV" b3="B88" />
      <ContingencyEquipment Action="X" Type="XF" b1="ERIEW" b2="345 KV" b3="NO3 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70700</SeqNum>
    <Name>L69.Quinton-Churchtown.0723</Name>
    <LastEdit Timestamp="2024-07-17T11:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="CU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="IO" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCHTO" b2="69 KV" b3="CHU-QUI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINTON" b2="69 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70730</SeqNum>
    <Name>138/69.Renaker.T1813</Name>
    <LastEdit Timestamp="2024-07-17T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RENAKER" b2="69 KV" b3="CB648" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RENAKER" b2="138 KV" b3="CB808" />
      <ContingencyEquipment Action="X" Type="XF" b1="RENAKER" b2="138 KV" b3="XF1813" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70750</SeqNum>
    <Name>L230.Wilson-Farmville-Greenville (CPL)</Name>
    <LastEdit Timestamp="2025-03-17T14:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FARMVIL" b2="230 KV" b3="BK1_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMVIL" b2="230 KV" b3="FAR-GVI" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMVIL" b2="230 KV" b3="FAR-XFRM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENVIL" b2="230 KV" b3="KDSSWLSN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENVIL" b2="230 KV" b3="WLSNGUC" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GVILWEST" b2="230 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENVIL" b2="230 KV" b3="GRE-GVI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GVILWEST" b2="230 KV" b3="XGRW1_LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GVILWEST" b2="230 KV" b3="XGRW2_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON4" b2="230 KV" b3="GNVL_2" />
      <ContingencyEquipment Action="L" Type="LN" b1="WILSON4" b2="230 KV" b3="WIL-XFRM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="XFRM" b2="230 KV" b3="XFMV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="XFRM" b2="230 KV" b3="XFRM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70870</SeqNum>
    <Name>L138.WartonHillSwitch-Calis</Name>
    <LastEdit Timestamp="2024-11-21T14:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CALIS" b2="138 KV" b3="AA" />
      <ContingencyEquipment Action="L" Type="LN" b1="CALIS" b2="138 KV" b3="CAL-WAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARTONHI" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70910</SeqNum>
    <Name>L138.Adams-WareRoad</Name>
    <LastEdit Timestamp="2024-07-17T11:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ADAMSAEP" b2="138 KV" b3="ADA-WAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSAEP" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSAEP" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAREROAD" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70920</SeqNum>
    <Name>L230.WestOrange-Marion-LaurelAve-Roseland.J-2288</Name>
    <LastEdit Timestamp="2024-10-08T16:20:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAURELAV" b2="230 KV" b3="LAU-MARJ" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAURELAV" b2="230 KV" b3="LAU-ROSJ" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LAURELAV" b2="13 KV" b3="T12TRAN" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LAURELAV" b2="13 KV" b3="T34TRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAURELAV" b2="230 KV" b3="TRAN T-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAURELAV" b2="230 KV" b3="TRAN T-4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MARIONDR" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MARIONDR" b2="230 KV" b3="TRAN T-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="18-20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="19-20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORANGE" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORANGE" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARIONDR" b2="230 KV" b3="MAR-WORJ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70930</SeqNum>
    <Name>L138.Westwood-Tippecanoe</Name>
    <LastEdit Timestamp="2024-07-17T11:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPPECAN" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTWOOD" b2="138 KV" b3="08" />
      <ContingencyEquipment Action="L" Type="LN" b1="WESTWOOD" b2="138 KV" b3="WES-TIP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>70980</SeqNum>
    <Name>L345.AllenJunction-Fulton</Name>
    <LastEdit Timestamp="2024-07-17T11:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENJUN" b2="345 KV" b3="ALL-FULT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="345 KV" b3="B34530" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="345 KV" b3="B34531" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULTONFE" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULTONFE" b2="345 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71000</SeqNum>
    <Name>L345.Fulton-NorthStarSteel</Name>
    <LastEdit Timestamp="2025-06-03T09:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FULTONFE" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULTONFE" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="FULTONFE" b2="345 KV" b3="FUL-NSTA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSTARSTL" b2="345 KV" b3="92" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NSTARSTL" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NSTARSTL" b2="34.5 KV" b3="CAP2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NSTARSTL" b2="34.5 KV" b3="CAP3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NSTARSTL" b2="34.5 KV" b3="CAP4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NSTARSTL" b2="34.5 KV" b3="EAP LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NSTARSTL" b2="34.5 KV" b3="FDR LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NSTARSTL" b2="34.5 KV" b3="SVC LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="NSTARSTL" b2="345 KV" b3="TR1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NSTARSTL" b2="345 KV" b3="TR2" />
      <ContingencyEquipment Action="X" Type="XF" b1="NSTARSTL" b2="345 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71010</SeqNum>
    <Name>L138.Delta-Fulton</Name>
    <LastEdit Timestamp="2024-07-17T11:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELTA" b2="138 KV" b3="B13430" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULTONFE" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULTONFE" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELTA" b2="138 KV" b3="DEL-FULT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71020</SeqNum>
    <Name>L138.Fulton-Swanton</Name>
    <LastEdit Timestamp="2025-07-25T16:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02SWANTN" b2="138 KV" b3="B13417" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02SWANTN" b2="138 KV" b3="B13425" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="02SWANTN" b2="138 KV" b3="CAP" />
      <ContingencyEquipment Action="L" Type="LN" b1="FULTONFE" b2="138 KV" b3="FUL-SWAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02SWANTN" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULTONFE" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULTONFE" b2="138 KV" b3="B8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71030</SeqNum>
    <Name>345/138.Fulton.TR1</Name>
    <LastEdit Timestamp="2024-07-17T11:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FULTONFE" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULTONFE" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULTONFE" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULTONFE" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="X" Type="XF" b1="FULTONFE" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71040</SeqNum>
    <Name>L138.Twinbranch-Concord</Name>
    <LastEdit Timestamp="2025-02-21T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONCORD" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONCORD" b2="138 KV" b3="CON-TWI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71050</SeqNum>
    <Name>L345.KansasWest-Zeke (Ameren)</Name>
    <LastEdit Timestamp="2025-07-07T15:12:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KANSAS 3" b2="345 KV" b3="KAN-ZEKE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANSAS 3" b2="345 KV" b3="V23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANSAS 3" b2="345 KV" b3="V25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZEKE" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZEKE" b2="345 KV" b3="V5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71060</SeqNum>
    <Name>345/34.EastWhitley.T1</Name>
    <LastEdit Timestamp="2024-07-17T11:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EWHITLEY" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWHITLEY" b2="34 KV" b3="52-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWHITLEY" b2="345 KV" b3="X1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71070</SeqNum>
    <Name>230/26.Sewaren.T220-2</Name>
    <LastEdit Timestamp="2024-12-16T17:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SEWAREN" b2="26 KV" b3="220-2LS" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEWAREN" b2="230 KV" b3="220-2XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71100</SeqNum>
    <Name>500/35.Mt.Storm.RSS6AndGT1</Name>
    <LastEdit Timestamp="2026-05-04T15:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MTSTORM4" b2="35 KV" b3="GT1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MTSTORM4" b2="500 KV" b3="RSS6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="SX6TB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="SX6TB3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="35 KV" b3="SXL22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71270</SeqNum>
    <Name>L138.Paddock-Bighillp</Name>
    <LastEdit Timestamp="2025-12-26T13:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGHILLP" b2="138 KV" b3="7054" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGHILLP" b2="138 KV" b3="7055" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADDOCK" b2="138 KV" b3="2258S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADDOCK" b2="138 KV" b3="2266S" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIGHILLP" b2="138 KV" b3="BIG-PADD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71280</SeqNum>
    <Name>L138.Paddock-BlackHawk</Name>
    <LastEdit Timestamp="2026-01-16T13:06:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKHA3" b2="138 KV" b3="1599-S" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKHA3" b2="138 KV" b3="BLA-NWBE" />
      <ContingencyEquipment Action="L" Type="LN" b1="NWBELOIT" b2="138 KV" b3="NWB-PADD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NWBELOIT" b2="138 KV" b3="T41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADDOCK" b2="138 KV" b3="2274S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADDOCK" b2="138 KV" b3="2282S" />
      <ContingencyEquipment Action="S" Type="SD" b1="PADDOCK" b2="138 KV" b3="X-53_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71310</SeqNum>
    <Name>L138.JacksonRoad-Twinbranch</Name>
    <LastEdit Timestamp="2024-07-17T12:36:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSONR" b2="138 KV" b3="JAC-TWI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="138 KV" b3="L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="V" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="V2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71330</SeqNum>
    <Name>345/138.103 Lisle.T81</Name>
    <LastEdit Timestamp="2024-07-17T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="103 LISL" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="103 LISL" b2="138 KV" b3="TR81CT-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="345 KV" b3="TR81HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="138 KV" b3="TR81LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71340</SeqNum>
    <Name>L230.Burlington-Mt Laurel-CoxsCorner.F-2284</Name>
    <LastEdit Timestamp="2024-07-18T10:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="2-9" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURLINGT" b2="230 KV" b3="BUR-MTL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COXSCORN" b2="230 KV" b3="1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COXSCORN" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="COXSCORN" b2="230 KV" b3="COX-MTLD" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MTLAUREL" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MTLAUREL" b2="230 KV" b3="TRAN T-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71390</SeqNum>
    <Name>345/138.FallCreek.XF2</Name>
    <LastEdit Timestamp="2024-07-18T10:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLCREE" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLCREE" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLCREE" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="X" Type="XF" b1="FALLCREE" b2="345 KV" b3="XF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71410</SeqNum>
    <Name>345/138.TannersCreek.T5</Name>
    <LastEdit Timestamp="2026-02-10T09:47:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TANNERSC" b2="345 KV" b3="5-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="TANNERSC" b2="138 KV" b3="5-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="M2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71430</SeqNum>
    <Name>L230.Hosensack-Springfield</Name>
    <LastEdit Timestamp="2024-07-18T10:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSME" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOSENSME" b2="230 KV" b3="HOS-SPR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRNGFLD" b2="230 KV" b3="HOSE_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRNGFLD" b2="230 KV" b3="HOSE_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71440</SeqNum>
    <Name>230/69.Springfield.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T12:11:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SPRNGFLD" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SPRNGFLD" b2="230 KV" b3="T2 MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRNGFLD" b2="69 KV" b3="TRAN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71450</SeqNum>
    <Name>L345.Zion(EnergyCntr/974)-Pleasant Prairie.PLPL41</Name>
    <LastEdit Timestamp="2024-07-18T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="974 ZION" b2="345 KV" b3="BT1-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="974 ZION" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="974 ZION" b2="345 KV" b3="PLPL41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEAS PR" b2="345 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEAS PR" b2="345 KV" b3="4-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71480</SeqNum>
    <Name>L138.Wooster-SaltCreek-Wmilburg</Name>
    <LastEdit Timestamp="2025-12-17T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SALTCREE" b2="138 KV" b3="HOLMCOOP" />
      <ContingencyEquipment Action="L" Type="LN" b1="SALTCREE" b2="138 KV" b3="SAL-WMIL" />
      <ContingencyEquipment Action="L" Type="LN" b1="SALTCREE" b2="138 KV" b3="SAL-WOOS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILBURG" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILBURG" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILBURG" b2="69 KV" b3="H013N5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILBURG" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WMILBURG" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WMILBURG" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILBURG" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOOSTER" b2="138 KV" b3="I" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71490</SeqNum>
    <Name>L69.OhioCentral-NorthCoshocton</Name>
    <LastEdit Timestamp="2026-03-26T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NCOSHOCT" b2="69 KV" b3="H020U8" />
      <ContingencyEquipment Action="L" Type="LN" b1="NCOSHOCT" b2="69 KV" b3="NCO-OHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="69 KV" b3="T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71500</SeqNum>
    <Name>138/69.OhioCentral.T2</Name>
    <LastEdit Timestamp="2024-12-31T13:17:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="OHIOCENT" b2="138 KV" b3="2-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OHIOCENT" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="69 KV" b3="T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71540</SeqNum>
    <Name>L138.133RockFall-H71Ess.13315</Name>
    <LastEdit Timestamp="2025-03-14T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="133 ROCK" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="133 ROCK" b2="138 KV" b3="BT1-5 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="133 ROCK" b2="138 KV" b3="13315 1" />
      <ContingencyEquipment Action="CL" Type="CB" b1="H71" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H71" b2="138 KV" b3="L13315CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71550</SeqNum>
    <Name>L138.WestLoop-Clybourn.14809</Name>
    <LastEdit Timestamp="2024-07-18T12:10:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="148 W LO" b2="138 KV" b3="14809" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT1-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT6-8 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="54 CLYBO" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71560</SeqNum>
    <Name>L345.MeldahlDamTap-Spurlock</Name>
    <LastEdit Timestamp="2025-06-03T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MELDALTP" b2="345 KV" b3="1535" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELDALTP" b2="345 KV" b3="1537" />
      <ContingencyEquipment Action="L" Type="LN" b1="MELDALTP" b2="345 KV" b3="MEL-SPU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB1464" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB152T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71570</SeqNum>
    <Name>L138.Mayfield-PineyGroveTap-LeroyCenter.Q3</Name>
    <LastEdit Timestamp="2024-07-18T10:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEROYCEN" b2="138 KV" b3="LER2-PIN" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAYFLD" b2="138 KV" b3="04M-PIN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEGROV" b2="138 KV" b3="CS332" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINEGROV" b2="138 KV" b3="PIN-PIN3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71590</SeqNum>
    <Name>L138.Pine-WadsworthMuni</Name>
    <LastEdit Timestamp="2025-05-20T11:12:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02WADS" b2="138 KV" b3="01-101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02WADS" b2="138 KV" b3="01-102" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINEOE" b2="138 KV" b3="PIN-02W1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEOE" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEOE" b2="138 KV" b3="B134" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71600</SeqNum>
    <Name>138/69.Hopewell.T1</Name>
    <LastEdit Timestamp="2024-07-18T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HOPEWELL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWELL" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWELL" b2="69 KV" b3="T1 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71620</SeqNum>
    <Name>L230.WestOrange-Marion-LaurelAve-Livingston.L-2290</Name>
    <LastEdit Timestamp="2024-10-08T16:18:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAURELAV" b2="230 KV" b3="LAU-LIVI" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAURELAV" b2="230 KV" b3="LAU-MARL" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LAURELAV" b2="13 KV" b3="T12TRAN" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LAURELAV" b2="13 KV" b3="T34TRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAURELAV" b2="230 KV" b3="TRAN T-1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAURELAV" b2="230 KV" b3="TRAN T-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIVINGPS" b2="230 KV" b3="1-2CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LIVINGPS" b2="230 KV" b3="T-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIVINGPS" b2="230 KV" b3="T-10B" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MARIONDR" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MARIONDR" b2="230 KV" b3="TRAN T-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORANGE" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORANGE" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARIONDR" b2="230 KV" b3="MAR-WORL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71630</SeqNum>
    <Name>L765.Maliszewski-Vassell</Name>
    <LastEdit Timestamp="2024-07-18T10:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MALISZEW" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="MALISZEW" b2="765 KV" b3="MAL-VAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="765 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="765 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71640</SeqNum>
    <Name>230/26.Sewaren.T220-3</Name>
    <LastEdit Timestamp="2024-12-16T17:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SEWAREN" b2="26 KV" b3="220-3LS" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEWAREN" b2="230 KV" b3="220-3XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71650</SeqNum>
    <Name>L230.Gloucester-CuthbertBlvd.D-2282</Name>
    <LastEdit Timestamp="2025-06-16T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUTHBERT" b2="230 KV" b3="1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUTHBERT" b2="230 KV" b3="2-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CUTHBERT" b2="230 KV" b3="CUT-GLO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUTHBERT" b2="230 KV" b3="T10" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CUTHBERT" b2="230 KV" b3="T10-20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="1-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="2-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71660</SeqNum>
    <Name>DTX230.WestOrange.T220-3</Name>
    <LastEdit Timestamp="2024-07-18T12:06:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WORANGE" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WORANGE" b2="230 KV" b3="220-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORANGE" b2="230 KV" b3="7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71680</SeqNum>
    <Name>L230.Metuchen-NewDover-Fanwood.H-2286</Name>
    <LastEdit Timestamp="2024-12-12T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FANWOOD" b2="230 KV" b3="TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FANWOOD" b2="230 KV" b3="TR10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="1-13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="13-14" />
      <ContingencyEquipment Action="L" Type="LN" b1="METUCHEN" b2="230 KV" b3="MET-NEWH" />
      <ContingencyEquipment Action="L" Type="LN" b1="FANWOOD" b2="230 KV" b3="FAN-NEWH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWDOVER" b2="230 KV" b3="T10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71700</SeqNum>
    <Name>L69.Queenstown-Wyemills</Name>
    <LastEdit Timestamp="2024-09-25T15:34:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="QUEENTWN" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUEENTWN" b2="69 KV" b3="66" />
      <ContingencyEquipment Action="L" Type="LN" b1="QUEENTWN" b2="69 KV" b3="QUE-WYE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="63" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71730</SeqNum>
    <Name>L138.EastElkhart-Elcona-Dunlap</Name>
    <LastEdit Timestamp="2025-03-24T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DUNLAP" b2="138 KV" b3="DUN-ELC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNLAP" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUNLAP" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNLAP" b2="138 KV" b3="XT3" />
      <ContingencyEquipment Action="L" Type="LN" b1="EELKHART" b2="138 KV" b3="EEL-ELC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="G1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELCONA" b2="138 KV" b3="ELC-ELC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELCONA" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71740</SeqNum>
    <Name>L115.Goudey-S.Owego</Name>
    <LastEdit Timestamp="2024-07-18T10:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOUDEY" b2="115 KV" b3="96102" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOUDEY" b2="115 KV" b3="GOU-SOW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOWEGO" b2="115 KV" b3="96172" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71780</SeqNum>
    <Name>L500.Brambleton-GooseCreek.558</Name>
    <LastEdit Timestamp="2026-05-18T09:01:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GOOSECRE" b2="500 KV" b3="558" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="500 KV" b3="558T589" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="500 KV" b3="H1T558" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRE" b2="500 KV" b3="55882-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRE" b2="500 KV" b3="55882-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71850</SeqNum>
    <Name>L230.Burlington-Levittown-Rancocas.B-2280</Name>
    <LastEdit Timestamp="2026-06-01T09:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURLINGT" b2="230 KV" b3="BUR-LEVB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEVITTOW" b2="230 KV" b3="LEV-RANC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEVITTOW" b2="230 KV" b3="T10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEVITTOW" b2="230 KV" b3="T30CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LEVITTOW" b2="230 KV" b3="TRAN1-2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LEVITTOW" b2="230 KV" b3="TRAN3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RANCOCAS" b2="230 KV" b3="1-2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RANCOCAS" b2="230 KV" b3="T-20CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71900</SeqNum>
    <Name>230/138.Essex.T220-2 + L138.Essex-Newark.H-1308</Name>
    <LastEdit Timestamp="2025-06-02T13:48:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ESSEX" b2="230 KV" b3="220-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="220-2T" />
      <ContingencyEquipment Action="S" Type="SD" b1="ESSEX" b2="138 KV" b3="H-1308" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="3-11" />
      <ContingencyEquipment Action="L" Type="LN" b1="ESSEX" b2="138 KV" b3="ESS-NEW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71920</SeqNum>
    <Name>L500.Loudoun-Mosby.584A</Name>
    <LastEdit Timestamp="2024-07-18T10:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="500 KV" b3="569T584" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="500 KV" b3="H2T584" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSBY" b2="500 KV" b3="559T584" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSBY" b2="500 KV" b3="58472" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOUDOUN4" b2="500 KV" b3="584A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71940</SeqNum>
    <Name>L138.Blacklick-OuterBelt-EBroadSt</Name>
    <LastEdit Timestamp="2026-05-08T14:59:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="OUTERBEL" b2="138 KV" b3="BLA-OUT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKLIC" b2="138 KV" b3="C CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLACKLIC" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBROAD" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBROAD" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="OUTERBEL" b2="138 KV" b3="EBR-OUT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OUTERBEL" b2="138 KV" b3="METAL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>71990</SeqNum>
    <Name>L138.Turner-Chemical</Name>
    <LastEdit Timestamp="2024-07-18T10:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="138 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHEMICAL" b2="138 KV" b3="CHE-TUR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72000</SeqNum>
    <Name>345/138.FostoriaCentral.T1</Name>
    <LastEdit Timestamp="2024-07-18T10:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FOSTORIA" b2="345 KV" b3=".  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="138 KV" b3="K2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72010</SeqNum>
    <Name>L500.Hopatcong-Ramapo.5018</Name>
    <LastEdit Timestamp="2025-06-04T14:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPATCON" b2="500 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPATCON" b2="500 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPATCON" b2="500 KV" b3="HOP-RAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="1500-2X" />
      <ContingencyEquipment Action="P" Type="XF" b1="RAMAPO" b2="345 KV" b3="345PAR1" />
      <ContingencyEquipment Action="P" Type="XF" b1="RAMAPO" b2="345 KV" b3="345PAR2" />
      <ContingencyEquipment Action="X" Type="XF" b1="RAMAPO" b2="500 KV" b3="BK1500" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="T1500-72" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72020</SeqNum>
    <Name>L500.Branchburg-Hopatcong.5060</Name>
    <LastEdit Timestamp="2025-06-03T09:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="500 KV" b3="14-15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="500 KV" b3="8-14" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPATCON" b2="500 KV" b3="BRA-HOP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPATCON" b2="500 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPATCON" b2="500 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72030</SeqNum>
    <Name>L115.NorthHanover-GittsRun.995</Name>
    <LastEdit Timestamp="2026-01-08T09:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GITTSRUN" b2="115 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GITTSRUN" b2="115 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="GITTSRUN" b2="115 KV" b3="GIT-NHA5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHANOVER" b2="115 KV" b3="99532" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72060</SeqNum>
    <Name>Chesapeake.SVC</Name>
    <LastEdit Timestamp="2025-02-20T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESAPKE" b2="230 KV" b3="BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESAPKE" b2="230 KV" b3="BUCK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESAPKE" b2="230 KV" b3="SV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="230 KV" b3="SV122" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72090</SeqNum>
    <Name>L230.Balston-RadnorHeights.2142A</Name>
    <LastEdit Timestamp="2025-03-24T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BALSTON" b2="69 KV" b3="143" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLARENDN" b2="230 KV" b3="2096" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALSTON" b2="230 KV" b3="20962142" />
      <ContingencyEquipment Action="L" Type="LN" b1="BALSTON" b2="230 KV" b3="2142A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALSTON" b2="230 KV" b3="H182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALSTON" b2="230 KV" b3="H282" />
      <ContingencyEquipment Action="X" Type="XF" b1="BALSTON" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BALSTON" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BALSTON" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RADNORHT" b2="230 KV" b3="20362142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RADNORHT" b2="230 KV" b3="214242" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72100</SeqNum>
    <Name>L230.Conemaugh-Seward</Name>
    <LastEdit Timestamp="2025-01-16T13:04:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONEMAUG" b2="230 KV" b3="B57" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONEMAUG" b2="230 KV" b3="CNM-SEW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="230 KV" b3="B-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWARD" b2="230 KV" b3="B-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72160</SeqNum>
    <Name>L230.Branchburg-Bridgewater.N-2319</Name>
    <LastEdit Timestamp="2024-07-18T10:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRANCHBU" b2="230 KV" b3="BRA-BRI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANCHBU" b2="230 KV" b3="SECT9-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEWA" b2="230 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEWA" b2="230 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72170</SeqNum>
    <Name>230/115.Lakeside.TX5</Name>
    <LastEdit Timestamp="2024-07-18T11:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="230 KV" b3="H522" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="115 KV" b3="H722" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="115 KV" b3="L5T111" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="115 KV" b3="L5T95" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKESID4" b2="230 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72180</SeqNum>
    <Name>230/115.Lakeside.TX8</Name>
    <LastEdit Timestamp="2024-07-18T12:05:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="230 KV" b3="H8T2127" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="230 KV" b3="H8T217" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="115 KV" b3="H922" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="115 KV" b3="L8T111" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="115 KV" b3="L8T95" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKESID4" b2="230 KV" b3="TX8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72200</SeqNum>
    <Name>L115.ForkUnion-Bremo.1030</Name>
    <LastEdit Timestamp="2025-09-03T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="115 KV" b3="103022" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRKUNION" b2="115 KV" b3="103072" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRKUNION" b2="115 KV" b3="1030A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRKUNION" b2="115 KV" b3="91T1030" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72210</SeqNum>
    <Name>L138.LaGrange-NorthPort (NIPS)</Name>
    <LastEdit Timestamp="2025-05-12T15:49:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAGRANGE" b2="138 KV" b3="87_130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAGRANGE" b2="138 KV" b3="87_2XFR" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAGRANGE" b2="138 KV" b3="LAG-NOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHPOR" b2="138 KV" b3="87_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHPOR" b2="138 KV" b3="87_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72220</SeqNum>
    <Name>L138.LaGrange-Hiple (NIPS)</Name>
    <LastEdit Timestamp="2025-06-20T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="138 KV" b3="13809" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="138 KV" b3="X109" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAGRANGE" b2="138 KV" b3="09_1XFR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAGRANGE" b2="138 KV" b3="09_2XFR" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIPLE" b2="138 KV" b3="HIP-LAG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72230</SeqNum>
    <Name>230/115.JacksonME.BK6</Name>
    <LastEdit Timestamp="2024-07-18T12:04:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="115 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="230 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="230 KV" b3="B8" />
      <ContingencyEquipment Action="X" Type="XF" b1="JACK ME" b2="230 KV" b3="BK6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72280</SeqNum>
    <Name>230/69.Sickler.T1</Name>
    <LastEdit Timestamp="2024-07-18T12:06:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SICKLER" b2="230 KV" b3="AW" />
      <ContingencyEquipment Action="X" Type="XF" b1="SICKLER" b2="230 KV" b3="SICK #1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SICKLER" b2="69 KV" b3="XFMROCBD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72290</SeqNum>
    <Name>230/69.Sickler.2</Name>
    <LastEdit Timestamp="2024-07-19T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SICKLER" b2="230 KV" b3="BV" />
      <ContingencyEquipment Action="X" Type="XF" b1="SICKLER" b2="230 KV" b3="SICK #2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SICKLER" b2="69 KV" b3="XFMROCBG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72300</SeqNum>
    <Name>L138.WMillersport-WHebron</Name>
    <LastEdit Timestamp="2025-09-03T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEBRON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="WHEBRON" b2="138 KV" b3="WHE-WMIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="138 KV" b3="C2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72310</SeqNum>
    <Name>L138.Brandywine-Carrcroft</Name>
    <LastEdit Timestamp="2026-02-10T08:57:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDYWN" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDYWN" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDYWN" b2="138 KV" b3="BRD-CAR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CARRCROF" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARRCROF" b2="138 KV" b3="134" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72320</SeqNum>
    <Name>L138.Brandywine-Edgemoor</Name>
    <LastEdit Timestamp="2026-02-10T08:59:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDYWN" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDYWN" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDYWN" b2="138 KV" b3="BRD-EDG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="3-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="3-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72340</SeqNum>
    <Name>L138.Greenfield-Hayes.1</Name>
    <LastEdit Timestamp="2024-07-19T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENFOE" b2="138 KV" b3="A136" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENFOE" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAYES_FE" b2="138 KV" b3="GRE-HAY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="138 KV" b3="B24" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72350</SeqNum>
    <Name>L138.Greenfield-Hayes.2</Name>
    <LastEdit Timestamp="2024-07-19T15:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENFOE" b2="138 KV" b3="A132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENFOE" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAYES_FE" b2="138 KV" b3="GRE-HAY2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="138 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="138 KV" b3="B33" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72360</SeqNum>
    <Name>345/138.Hayes.TR1</Name>
    <LastEdit Timestamp="2024-07-19T15:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="345 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="138 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="138 KV" b3="B42" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAYES_FE" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72370</SeqNum>
    <Name>L345.DavisBesse-Hayes</Name>
    <LastEdit Timestamp="2026-01-20T17:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B66" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B67" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="345 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="345 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAYES_FE" b2="345 KV" b3="DAV-HAY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72380</SeqNum>
    <Name>L345.Beaver-Hayes</Name>
    <LastEdit Timestamp="2026-01-07T10:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="88" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="345 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAYES_FE" b2="345 KV" b3="BEA-HAY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72390</SeqNum>
    <Name>345/138.16Waukegan.TR81</Name>
    <LastEdit Timestamp="2024-11-27T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="16 WAUKE" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="16 WAUKE" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72400</SeqNum>
    <Name>345/138.16Waukegan.TR83</Name>
    <LastEdit Timestamp="2024-11-27T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="345 KV" b3="BT4-5CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="345 KV" b3="BT5-6CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="16 WAUKE" b2="345 KV" b3="TR83CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="16 WAUKE" b2="138 KV" b3="TR83CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72410</SeqNum>
    <Name>L345.Waukegan-Northbrook.1625</Name>
    <LastEdit Timestamp="2025-01-30T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="159 NORT" b2="345 KV" b3="L1625" />
      <ContingencyEquipment Action="L" Type="LN" b1="159 NORT" b2="345 KV" b3="1625" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="345 KV" b3="BT4-6CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="345 KV" b3="BT5-6CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="345 KV" b3="BT6-11CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72430</SeqNum>
    <Name>L500.Hopatcong-Roseland.5061</Name>
    <LastEdit Timestamp="2025-06-04T14:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPATCON" b2="500 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPATCON" b2="500 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPATCON" b2="500 KV" b3="HOP-ROS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="500 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="500 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72440</SeqNum>
    <Name>500/230.Roseland.TR1</Name>
    <LastEdit Timestamp="2024-07-19T15:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ROSELAND" b2="500 KV" b3="1TRX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="500 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="500 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="9-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="9-15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72450</SeqNum>
    <Name>500/230.Roseland.TR2</Name>
    <LastEdit Timestamp="2024-07-19T15:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="500 KV" b3="2-8" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROSELAND" b2="500 KV" b3="2TRX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="6-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="6-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="500 KV" b3="7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72470</SeqNum>
    <Name>L115.Nasa-Peninsula.1</Name>
    <LastEdit Timestamp="2024-10-31T08:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="NASADOM" b2="115 KV" b3="DUM" />
      <ContingencyEquipment Action="L" Type="LN" b1="NASADOM" b2="115 KV" b3="PEN-NAS1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NASADOM" b2="22 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NASADOM" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENINSLA" b2="115 KV" b3="T12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72480</SeqNum>
    <Name>L230.Kingsland-Kearny.B-2307</Name>
    <LastEdit Timestamp="2024-07-30T14:50:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEARNY" b2="230 KV" b3="KEA-TURB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSLAN" b2="230 KV" b3="1-2CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KINGSLAN" b2="230 KV" b3="DUM4" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGSLAN" b2="230 KV" b3="KIN-TURB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSLAN" b2="230 KV" b3="T-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSLAN" b2="230 KV" b3="TRANT-4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="TURNPIKE" b2="230 KV" b3="LOADTRAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72490</SeqNum>
    <Name>L138.Wythe-Progress</Name>
    <LastEdit Timestamp="2024-07-19T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PROGRESS" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYTHE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="PROGRESS" b2="138 KV" b3="PRO-WYT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72520</SeqNum>
    <Name>L115.MaysChapel-MtWashington.110701</Name>
    <LastEdit Timestamp="2024-10-23T13:29:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="COLDSPRI" b2="13.8 KV" b3="TIEBKR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYSCHAP" b2="115 KV" b3="110509" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYSCHAP" b2="115 KV" b3="110579-C" />
      <ContingencyEquipment Action="CL" Type="CB" b1="MTWASHIG" b2="13.8 KV" b3="1-2" />
      <ContingencyEquipment Action="CL" Type="CB" b1="MTWASHIG" b2="13.8 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTWASHIG" b2="13.8 KV" b3="110-4 LS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="MTWASHIG" b2="13.8 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTWASHIG" b2="115 KV" b3="4TR703" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAYSCHAP" b2="115 KV" b3="MAY-MTW1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72530</SeqNum>
    <Name>L115.MaysChapel-MtWashington.110702</Name>
    <LastEdit Timestamp="2024-10-23T13:30:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="COLDSPRI" b2="13.8 KV" b3="TIEBKR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYSCHAP" b2="115 KV" b3="110515-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYSCHAP" b2="115 KV" b3="110578-A" />
      <ContingencyEquipment Action="CL" Type="CB" b1="MTWASHIG" b2="13.8 KV" b3="1-2" />
      <ContingencyEquipment Action="CL" Type="CB" b1="MTWASHIG" b2="13.8 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTWASHIG" b2="13.8 KV" b3="110-5 LS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="MTWASHIG" b2="13.8 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTWASHIG" b2="115 KV" b3="5TR704" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAYSCHAP" b2="115 KV" b3="MAY-MTW2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72540</SeqNum>
    <Name>L115.MtWashington-CampSmall-ColdSpring.110703</Name>
    <LastEdit Timestamp="2024-11-13T14:52:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPSMAL" b2="115 KV" b3="110703CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPSMAL" b2="115 KV" b3="703_704" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMPSMAL" b2="115 KV" b3="CAM-COL3" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMPSMAL" b2="115 KV" b3="CAM-MTW3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="COLDSPRI" b2="115 KV" b3="12BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLDSPRI" b2="115 KV" b3="703 CSW" />
      <ContingencyEquipment Action="CL" Type="CB" b1="MTWASHIG" b2="13.8 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MTWASHIG" b2="115 KV" b3="110-4CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTWASHIG" b2="115 KV" b3="4TR703" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72550</SeqNum>
    <Name>L115.MtWashington-CampSmall-ColdSpring.110704</Name>
    <LastEdit Timestamp="2024-11-13T14:53:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPSMAL" b2="115 KV" b3="110704CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPSMAL" b2="115 KV" b3="703_704" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMPSMAL" b2="115 KV" b3="CAM-COL4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMPSMAL" b2="115 KV" b3="CAM-MTW4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="COLDSPRI" b2="115 KV" b3="12BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLDSPRI" b2="115 KV" b3="704 CSW" />
      <ContingencyEquipment Action="CL" Type="CB" b1="MTWASHIG" b2="13.8 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MTWASHIG" b2="115 KV" b3="110-5CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTWASHIG" b2="115 KV" b3="5TR704" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72560</SeqNum>
    <Name>L138.WestCanton-Promway-Wayview</Name>
    <LastEdit Timestamp="2024-11-04T13:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PROMWAY" b2="138 KV" b3="PRO-WAY1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PROMWAY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PROMWAY" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PROMWAY" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYVIEW" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="PROMWAY" b2="138 KV" b3="PRO-WCA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72570</SeqNum>
    <Name>L138.Heath-WestMillersport</Name>
    <LastEdit Timestamp="2024-07-19T15:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HEATH" b2="138 KV" b3="HEA-WMI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATH" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72580</SeqNum>
    <Name>L345.Waukegan-Zion.2218</Name>
    <LastEdit Timestamp="2024-07-19T15:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="345 KV" b3="BT6-11CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="16 WAUKE" b2="345 KV" b3="BT9-11CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="16 WAUKE" b2="345 KV" b3="L2218" />
      <ContingencyEquipment Action="OP" Type="CB" b1="22 ZION" b2="345 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="22 ZION" b2="345 KV" b3="BT6-7 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72620</SeqNum>
    <Name>L138.58Grand-34Kingsbury.5803</Name>
    <LastEdit Timestamp="2025-06-20T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="34 KINGS" b2="138 KV" b3="5803 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="34 KINGS" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT4-5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72630</SeqNum>
    <Name>L138.58Grand-34Kingsbury.5804</Name>
    <LastEdit Timestamp="2025-06-20T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="34 KINGS" b2="138 KV" b3="5804 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="34 KINGS" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT7-8 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72640</SeqNum>
    <Name>L138.58Grand-65Ohio.5806</Name>
    <LastEdit Timestamp="2025-07-15T13:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1213CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="65 OHIO" b2="138 KV" b3="5806 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="65 OHIO" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72650</SeqNum>
    <Name>L138.58Grand-65Ohio.5809</Name>
    <LastEdit Timestamp="2025-06-20T15:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1516CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1617CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="65 OHIO" b2="138 KV" b3="5809 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="65 OHIO" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72660</SeqNum>
    <Name>L138.785Ontario-148WestLoop.14812</Name>
    <LastEdit Timestamp="2025-06-20T15:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT1213CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="148 W LO" b2="138 KV" b3="14812" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="785 ONTA" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72670</SeqNum>
    <Name>L138.Ontario-WestLoop.14813</Name>
    <LastEdit Timestamp="2025-03-27T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="148 W LO" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="148 W LO" b2="138 KV" b3="14813" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="785 ONTA" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72680</SeqNum>
    <Name>L230.Camden-LevitTown.M-2291</Name>
    <LastEdit Timestamp="2025-01-17T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDEN" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDEN" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEVITTOW" b2="230 KV" b3="1-2CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMDEN" b2="230 KV" b3="CAM-LEVM" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEVITTOW" b2="230 KV" b3="LEV-MTLE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEVITTOW" b2="230 KV" b3="T20CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEVITTOW" b2="230 KV" b3="T40CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LEVITTOW" b2="230 KV" b3="TRAN1-2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LEVITTOW" b2="230 KV" b3="TRAN3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72690</SeqNum>
    <Name>L230.Camden-Cinnaminson.Q-2295</Name>
    <LastEdit Timestamp="2026-06-01T09:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDEN" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDEN" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMDEN" b2="230 KV" b3="CAM-CINQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CINNAMIN" b2="230 KV" b3="1-2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CINNAMIN" b2="230 KV" b3="T20CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CINNAMIN" b2="230 KV" b3="T40CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CINNAMIN" b2="230 KV" b3="TRAN1-2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CINNAMIN" b2="230 KV" b3="TRAN3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72700</SeqNum>
    <Name>L230.Burlington-Cinnaminson-Camden.A-2279</Name>
    <LastEdit Timestamp="2024-07-19T15:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="2-7" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURLINGT" b2="230 KV" b3="BUR-CINA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDEN" b2="230 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDEN" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMDEN" b2="230 KV" b3="CAM-CINA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CINNAMIN" b2="230 KV" b3="T10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CINNAMIN" b2="230 KV" b3="T30CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CINNAMIN" b2="230 KV" b3="TRAN1-2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CINNAMIN" b2="230 KV" b3="TRAN3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72720</SeqNum>
    <Name>230/115.Sayreville.T17</Name>
    <LastEdit Timestamp="2024-07-19T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SAYREVIL" b2="230 KV" b3="17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="115 KV" b3="B44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="B75" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="115 KV" b3="B79" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72730</SeqNum>
    <Name>138.167Plano.Caps1&amp;2</Name>
    <LastEdit Timestamp="2025-03-27T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="138 KV" b3="C1-2 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="167 PLAN" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="167 PLAN" b2="138 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72740</SeqNum>
    <Name>L138.Plano-Sandwich.14609</Name>
    <LastEdit Timestamp="2025-10-10T13:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="146 SAND" b2="138 KV" b3="14609 Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="146 SAND" b2="138 KV" b3="609-301" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="146 SAND" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="146 SAND" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="167 PLAN" b2="138 KV" b3="14609 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="14609" b2="138 KV" b3="14609 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="14609" b2="138 KV" b3="14609 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="138 KV" b3="L14609CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="527PLANO" b2="138 KV" b3="TR76" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72750</SeqNum>
    <Name>345/138.167Plano.TR81</Name>
    <LastEdit Timestamp="2024-12-02T12:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="167 PLAN" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="167 PLAN" b2="345 KV" b3="TR81 CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="167 PLAN" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="167 PLAN" b2="138 KV" b3="TR81CT-S" />
      <ContingencyEquipment Action="S" Type="SD" b1="167 PLAN" b2="138 KV" b3="TR81I" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>72760</SeqNum>
    <Name>L138.BethelPark-Wilson.Z-17</Name>
    <LastEdit Timestamp="2024-07-19T15:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHELPA" b2="138 KV" b3="WILSONCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHELPA" b2="138 KV" b3="BET-WIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE3-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE8-7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73050</SeqNum>
    <Name>Meadowbrook.SVC</Name>
    <LastEdit Timestamp="2024-07-19T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="500 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="500 KV" b3="B18" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEADOWBR" b2="500 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73060</SeqNum>
    <Name>Hunterstown.SVC</Name>
    <LastEdit Timestamp="2024-10-17T15:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="500 KV" b3="B117" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="500 KV" b3="B40" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUNTERST" b2="500 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73070</SeqNum>
    <Name>L230.Sewaren-Woodbrdge-LafayetteRd-Metuchen.X-2303</Name>
    <LastEdit Timestamp="2024-07-22T13:19:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAFA PS" b2="230 KV" b3="LAF-WOOX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAFA PS" b2="230 KV" b3="T-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="230SC3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAFA PS" b2="230 KV" b3="LAF-METX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEWAREN" b2="230 KV" b3="SEW-WOOX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODBRID" b2="230 KV" b3="T1LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73080</SeqNum>
    <Name>345/138.Kammer.T301</Name>
    <LastEdit Timestamp="2024-07-19T15:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="345 KV" b3="BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="345 KV" b3="BB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="H CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="H1 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="KAMMER2" b2="345 KV" b3="TR301" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73110</SeqNum>
    <Name>L138.Gahanna-WestMillersport</Name>
    <LastEdit Timestamp="2024-07-19T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="113" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="114" />
      <ContingencyEquipment Action="L" Type="LN" b1="GAHANNA" b2="138 KV" b3="GAH-WMI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="138 KV" b3="A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="138 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73130</SeqNum>
    <Name>L138.HyattCS-Sawmill.2</Name>
    <LastEdit Timestamp="2024-07-22T12:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="103C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="103S" />
      <ContingencyEquipment Action="L" Type="LN" b1="HYATTCS" b2="138 KV" b3="HYA-SAW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="103C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="103N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73170</SeqNum>
    <Name>L138.Wilson-Mitchell.Z-11</Name>
    <LastEdit Timestamp="2024-07-22T12:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MITCHELL" b2="138 KV" b3="MIT-WIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHELL" b2="138 KV" b3="WILSONCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE3-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE5-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73180</SeqNum>
    <Name>L345.Armstrong-HomerCity</Name>
    <LastEdit Timestamp="2024-08-01T08:01:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMSTRON" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMSTRON" b2="345 KV" b3="B48" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARMSTRON" b2="345 KV" b3="ARM-HOM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="345 KV" b3="B301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="345 KV" b3="B302" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73190</SeqNum>
    <Name>345/138.Armstrong.T2</Name>
    <LastEdit Timestamp="2025-11-21T12:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMSTRON" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMSTRON" b2="345 KV" b3="B48" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMSTRON" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="X" Type="XF" b1="ARMSTRON" b2="345 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73200</SeqNum>
    <Name>345/138.Bayshore.T2</Name>
    <LastEdit Timestamp="2026-01-02T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BAYSHOR2" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="138 KV" b3="3J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="138 KV" b3="3K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="345 KV" b3="42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="345 KV" b3="B28" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73230</SeqNum>
    <Name>L345.Hanna-Mansfield (OE)</Name>
    <LastEdit Timestamp="2025-08-22T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNAOE" b2="345 KV" b3="B105" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANSFIEL" b2="345 KV" b3="HAN-MAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="27" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73240</SeqNum>
    <Name>L230.BirchWood-Comorn-ArnoldCorner-Dahlgren.2145</Name>
    <LastEdit Timestamp="2025-06-16T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARNOLDCR" b2="230 KV" b3="ARN-COMO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARNOLDCR" b2="230 KV" b3="H132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARNOLDCR" b2="230 KV" b3="H232" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ARNOLDCR" b2="35 KV" b3="KGORGELF" />
      <ContingencyEquipment Action="X" Type="XF" b1="ARNOLDCR" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ARNOLDCR" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ARNOLDCR" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ARNOLDCR" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIRCHWD" b2="230 KV" b3="214512" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIRCHWD" b2="230 KV" b3="BIR-COMO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COMORNDP" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAHLGREN" b2="230 KV" b3="214582-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAHLGREN" b2="230 KV" b3="214582-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARNOLDCR" b2="230 KV" b3="2145B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73250</SeqNum>
    <Name>115/34.Warren.TXA</Name>
    <LastEdit Timestamp="2024-07-22T11:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="115 KV" b3="B94" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="115 KV" b3="B96" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="34 KV" b3="FORGE F1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WARREN" b2="115 KV" b3="TX A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73260</SeqNum>
    <Name>L230.Mickleton-CrownPoint &amp; Plant</Name>
    <LastEdit Timestamp="2025-04-24T14:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CROWNPNT" b2="18 KV" b3="CTG1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROWNPNT" b2="18 KV" b3="CTG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROWNPNT" b2="230 KV" b3="HVB01" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROWNPNT" b2="230 KV" b3="HVB02" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROWNPNT" b2="230 KV" b3="HVB03" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROWNPNT" b2="230 KV" b3="HVB04" />
      <ContingencyEquipment Action="L" Type="LN" b1="MICKLETO" b2="230 KV" b3="MIC-CRO" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CROWNPNT" b2="21 KV" b3="STG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="DT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73270</SeqNum>
    <Name>BlackOak.SVC</Name>
    <LastEdit Timestamp="2025-04-02T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKOAK" b2="500 KV" b3="BOL10 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BLACKOAK" b2="500 KV" b3="BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BLACKOAK" b2="500 KV" b3="BUCK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BLACKOAK" b2="500 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73280</SeqNum>
    <Name>Altoona.SVC</Name>
    <LastEdit Timestamp="2025-02-20T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTOONA" b2="230 KV" b3="B27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTOONA" b2="230 KV" b3="B50" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ALTOONA" b2="230 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73290</SeqNum>
    <Name>230/115.Johnstown.T1</Name>
    <LastEdit Timestamp="2024-07-22T11:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSTOW" b2="230 KV" b3="B35" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSTOW" b2="115 KV" b3="B38" />
      <ContingencyEquipment Action="X" Type="XF" b1="JOHNSTOW" b2="230 KV" b3="NO1 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73340</SeqNum>
    <Name>L69.Motts-MossMill.0796</Name>
    <LastEdit Timestamp="2025-07-18T13:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSSMILL" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSSMILL" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOSSMILL" b2="69 KV" b3="MOS-MOTT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTTS" b2="69 KV" b3="ABS J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73370</SeqNum>
    <Name>345/138.Shelby.BK-S</Name>
    <LastEdit Timestamp="2024-11-04T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SHELBY" b2="345 KV" b3="BK-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="138 KV" b3="BLS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="345 KV" b3="DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="345 KV" b3="HH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73410</SeqNum>
    <Name>L345.Vassell-HyattCS</Name>
    <LastEdit Timestamp="2025-10-14T18:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="J1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HYATTCS" b2="345 KV" b3="HYA-VAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="345 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="345 KV" b3="J1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73420</SeqNum>
    <Name>L345.Corridor-Vassell.2</Name>
    <LastEdit Timestamp="2025-10-14T18:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="345 KV" b3="302C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="345 KV" b3="302N" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORRIDOR" b2="345 KV" b3="COR-VAS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="345 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="345 KV" b3="G1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73430</SeqNum>
    <Name>L138.SharpRoad-WMtVernon</Name>
    <LastEdit Timestamp="2025-09-30T20:44:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARPROA" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMTVERNO" b2="138 KV" b3="H000V8" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHARPROA" b2="138 KV" b3="SHA-WMT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73440</SeqNum>
    <Name>L230.Essex-NewarkEnergyCenter.Q-2322</Name>
    <LastEdit Timestamp="2024-07-25T15:35:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="1-15CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="15-16CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ESSEX" b2="230 KV" b3="ESS-NEC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARKEC" b2="230 KV" b3="52-L01" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73450</SeqNum>
    <Name>NewarkEnergyCenter.CC10&amp;11&amp;12</Name>
    <LastEdit Timestamp="2024-07-25T15:37:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARKEC" b2="230 KV" b3="52-L01" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWARKEC" b2="18 KV" b3="CT1_LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWARKEC" b2="18 KV" b3="CT2_LD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWARKEC" b2="18 KV" b3="CTG11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWARKEC" b2="18 KV" b3="CTG12" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWARKEC" b2="230 KV" b3="GSU10" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWARKEC" b2="230 KV" b3="GSU11" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWARKEC" b2="230 KV" b3="GSU12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWARKEC" b2="18 KV" b3="STG10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73670</SeqNum>
    <Name>L230.BloomingGr-Paupack+BloomingGr.T2</Name>
    <LastEdit Timestamp="2024-09-23T10:56:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BLOOMING" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLOOMING" b2="230 KV" b3="BLO-PAU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLOOMING" b2="230 KV" b3="PAUPBUSH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLOOMING" b2="69 KV" b3="TRAN_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAUPACK" b2="230 KV" b3="BLGR_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAUPACK" b2="230 KV" b3="BLGR_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73690</SeqNum>
    <Name>230/69.Paupack.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T13:58:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PAUPACK" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAUPACK" b2="69 KV" b3="TRAN1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PAUPACK" b2="230 KV" b3="TRAN1MOD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73700</SeqNum>
    <Name>230/69.Paupack.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T14:00:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PAUPACK" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAUPACK" b2="69 KV" b3="TRAN2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PAUPACK" b2="230 KV" b3="TRAN2MOD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73710</SeqNum>
    <Name>230/35.Cookstown.BK2</Name>
    <LastEdit Timestamp="2025-11-12T14:28:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOKSTOW" b2="230 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOKSTOW" b2="230 KV" b3="B37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOKSTOW" b2="230 KV" b3="B39" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOKSTOW" b2="35 KV" b3="B80" />
      <ContingencyEquipment Action="X" Type="XF" b1="COOKSTOW" b2="230 KV" b3="BK 2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOKSTOW" b2="35 KV" b3="BK2B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="COOKSTOW" b2="230 KV" b3="CAP3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73720</SeqNum>
    <Name>230/35.Cookstown.BK1</Name>
    <LastEdit Timestamp="2024-07-25T15:38:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="COOKSTOW" b2="230 KV" b3="BK 1TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOKSTOW" b2="35 KV" b3="BK1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOKSTOW" b2="35 KV" b3="BK1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOKSTOW" b2="230 KV" b3="CS56" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73730</SeqNum>
    <Name>L230.Charlottesville-Proffit-Hollymead.2054</Name>
    <LastEdit Timestamp="2025-06-16T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLTSV" b2="230 KV" b3="20282054" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLTSV" b2="230 KV" b3="2054B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLTSV" b2="230 KV" b3="291T2054" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHARLTSV" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHARLTSV" b2="35 KV" b3="TX4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLYMD" b2="230 KV" b3="20542135" />
      <ContingencyEquipment Action="L" Type="LN" b1="PROFITDP" b2="230 KV" b3="2054AC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PROFITDP" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PROFITDP" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73760</SeqNum>
    <Name>L230.Roseland-FrontSt.I-2287</Name>
    <LastEdit Timestamp="2025-07-24T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTST" b2="230 KV" b3="1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTST" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRONTST" b2="230 KV" b3="FRO-ROS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="7-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="7-15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73770</SeqNum>
    <Name>L230.WestOrange-SpringfieldRoad.N-2292</Name>
    <LastEdit Timestamp="2024-07-22T13:05:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGRD" b2="230 KV" b3="1-2CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="SPRINGRD" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGRD" b2="230 KV" b3="T10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORANGE" b2="230 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORANGE" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPRINGRD" b2="230 KV" b3="SPR-WORN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73790</SeqNum>
    <Name>345/138.Kammer.T302</Name>
    <LastEdit Timestamp="2024-07-22T12:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="345 KV" b3="BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="345 KV" b3="BB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="X" Type="XF" b1="KAMMER2" b2="345 KV" b3="TR302" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73800</SeqNum>
    <Name>345/138.CantonCentral.T3</Name>
    <LastEdit Timestamp="2024-07-22T12:00:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="345 KV" b3="T3" />
      <ContingencyEquipment Action="X" Type="XF" b1="CANTONCE" b2="345 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73820</SeqNum>
    <Name>L69.Glenbrook-Salem-Berwick-Products</Name>
    <LastEdit Timestamp="2026-01-12T12:15:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BERCON" b2="69 KV" b3="BER-WBER" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERCON" b2="69 KV" b3="BERC LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERCON" b2="69 KV" b3="BER-BERW" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERWICK" b2="69 KV" b3="BER-SAL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERWICK" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="69 KV" b3="COLU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="69 KV" b3="HUNLCOLU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PRODUCTS" b2="69 KV" b3="PROD LD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SALEMPL" b2="69 KV" b3="4265" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENBROO" b2="69 KV" b3="GLE-SAL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SALEMPL" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SCOTTPL" b2="69 KV" b3="4251" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WBERWICK" b2="69 KV" b3="4255" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRODUCTS" b2="69 KV" b3="PRO-WBER" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73830</SeqNum>
    <Name>FremonteEnergyCenter.CC1&amp;2&amp;3</Name>
    <LastEdit Timestamp="2025-02-18T15:45:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONTE" b2="138 KV" b3="B190" />
      <ContingencyEquipment Action="X" Type="XF" b1="FREMONTE" b2="138 KV" b3="CT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONTE" b2="18 KV" b3="CT1_BRK" />
      <ContingencyEquipment Action="X" Type="XF" b1="FREMONTE" b2="138 KV" b3="CT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONTE" b2="18 KV" b3="CT2_BRK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FREMONTE" b2="18 KV" b3="FT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FREMONTE" b2="18 KV" b3="FT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FREMONTE" b2="23 KV" b3="FT3" />
      <ContingencyEquipment Action="X" Type="XF" b1="FREMONTE" b2="138 KV" b3="ST" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73840</SeqNum>
    <Name>L138.SAkron-Neffsvl-Rosevl-EPete-PrkCit-Dillervl.2</Name>
    <LastEdit Timestamp="2024-07-26T12:57:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="DILLERVI" b2="138 KV" b3="DONNEL2" />
      <ContingencyEquipment Action="X" Type="XF" b1="DILLERVI" b2="138 KV" b3="TRAN 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DILLERVI" b2="13 KV" b3="TRAN_2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EPETERSB" b2="138 KV" b3="TRAN2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEFFSVIL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DILLERVI" b2="138 KV" b3="DIL-PAR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPETERSB" b2="138 KV" b3="EPE-PAR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PARKCITY" b2="138 KV" b3="PARK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPETERSB" b2="138 KV" b3="EPE-ROS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROSEVILL" b2="138 KV" b3="LOAD2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEFFSVIL" b2="138 KV" b3="NEF-ROS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROSEVILL" b2="138 KV" b3="ROSE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="138 KV" b3="DILL2-E" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEFFSVIL" b2="138 KV" b3="NEF-SAK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="138 KV" b3="P2-D2TIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73850</SeqNum>
    <Name>L138.SAkron-Neffsvlle-EPetersb-ParkCit-Diller.1</Name>
    <LastEdit Timestamp="2025-03-27T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DILLERVI" b2="13 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DILLERVI" b2="138 KV" b3="TRAN 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DILLERVI" b2="13 KV" b3="TRAN_1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EPETERSB" b2="138 KV" b3="TRAN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPETERSB" b2="138 KV" b3="EPE-NEF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEFFSVIL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DILLERVI" b2="138 KV" b3="DIL-PAR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPETERSB" b2="138 KV" b3="EPE-PAR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PARKCITY" b2="138 KV" b3="PARK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="138 KV" b3="DILL1-E" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEFFSVIL" b2="138 KV" b3="NEF-SAK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="138 KV" b3="P1-D1TIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73860</SeqNum>
    <Name>L230.JerichoPark-BuenaVista.2350</Name>
    <LastEdit Timestamp="2025-04-21T15:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23016_50" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23016_51" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23025_50" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23025_51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JERICHOP" b2="230 KV" b3="230-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JERICHOP" b2="230 KV" b3="2340-50" />
      <ContingencyEquipment Action="L" Type="LN" b1="JERICHOP" b2="230 KV" b3="BUE-JER0" />
      <ContingencyEquipment Action="CL" Type="CB" b1="JERICHOP" b2="230 KV" b3="TIECB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73870</SeqNum>
    <Name>L230.JerichoPark-BuenaVista.2351</Name>
    <LastEdit Timestamp="2025-04-21T15:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23016_50" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23016_51" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23025_50" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUENAVIS" b2="230 KV" b3="23025_51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JERICHOP" b2="230 KV" b3="230-2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JERICHOP" b2="230 KV" b3="2341-51" />
      <ContingencyEquipment Action="L" Type="LN" b1="JERICHOP" b2="230 KV" b3="BUE-JER1" />
      <ContingencyEquipment Action="CL" Type="CB" b1="JERICHOP" b2="230 KV" b3="TIECB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73890</SeqNum>
    <Name>L138.Dravosburg-Wilson.Z-72</Name>
    <LastEdit Timestamp="2024-07-22T12:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DRAVOSBU" b2="138 KV" b3="DRA-WIL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="Z-72CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE6-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE7-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73940</SeqNum>
    <Name>L69.22ndSt-Takoma.69051</Name>
    <LastEdit Timestamp="2025-02-11T09:14:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="22ST" b2="69 KV" b3="1T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="22ST" b2="13.8 KV" b3="1TSB" />
      <ContingencyEquipment Action="L" Type="LN" b1="22ST" b2="69 KV" b3="22S-TAK4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K10B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K8B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73950</SeqNum>
    <Name>L69.22ndSt-Takoma.69042</Name>
    <LastEdit Timestamp="2025-08-12T04:02:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="22ST" b2="69 KV" b3="22S-TAK5" />
      <ContingencyEquipment Action="X" Type="XF" b1="22ST" b2="69 KV" b3="4T" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="22ST" b2="69 KV" b3="4TP-MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="22ST" b2="13.8 KV" b3="4TSB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K5B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73960</SeqNum>
    <Name>L69.22ndSt-Takoma.69041 + 69/13.22ndSt.3T</Name>
    <LastEdit Timestamp="2026-03-05T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="22ST" b2="69 KV" b3="22S-TAK6" />
      <ContingencyEquipment Action="X" Type="XF" b1="22ST" b2="69 KV" b3="3T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="22ST" b2="13.8 KV" b3="3TSB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K6B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73970</SeqNum>
    <Name>L69.22ndSt-Takoma.69052</Name>
    <LastEdit Timestamp="2025-02-13T08:34:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="22ST" b2="69 KV" b3="22S-TAK7" />
      <ContingencyEquipment Action="X" Type="XF" b1="22ST" b2="69 KV" b3="2T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="22ST" b2="13.8 KV" b3="2TSB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K7B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K9B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73980</SeqNum>
    <Name>L230.PleasntView-EdwardsFerry-Dickerson.23111/203A</Name>
    <LastEdit Timestamp="2024-07-22T13:22:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DICKERSO" b2="230 KV" b3="7ABCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDWSFERY" b2="230 KV" b3="203A" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDWSFERY" b2="230 KV" b3="23111" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDWSFERY" b2="230 KV" b3="H162" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDWSFERY" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDWSFERY" b2="34.5 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="230 KV" b3="203T274" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="230 KV" b3="L3T203" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PLEASNTV" b2="230 KV" b3="SC3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="230 KV" b3="SC322" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>73990</SeqNum>
    <Name>L230.Lakeside-MountainRoad-Northwest.2127</Name>
    <LastEdit Timestamp="2025-06-18T13:21:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="230 KV" b3="216T2127" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="230 KV" b3="H522" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKESID4" b2="230 KV" b3="H8T2127" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTNROAD" b2="230 KV" b3="H212" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MTNROAD" b2="35 KV" b3="HENRICLF" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKESID4" b2="230 KV" b3="LAK-MTNR" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTNROAD" b2="230 KV" b3="MTN-NWES" />
      <ContingencyEquipment Action="X" Type="XF" b1="MTNROAD" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTNROAD" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWEST" b2="230 KV" b3="212752" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWEST" b2="230 KV" b3="221T2127" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWEST" b2="230 KV" b3="H252" />
      <ContingencyEquipment Action="X" Type="XF" b1="NWEST" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NWEST" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74000</SeqNum>
    <Name>L230.Dooms-Staunton.2156</Name>
    <LastEdit Timestamp="2024-07-22T12:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="215642" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="233T2156" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="H542" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOOMS4" b2="230 KV" b3="TX5" />
      <ContingencyEquipment Action="L" Type="LN" b1="STAUNTON" b2="230 KV" b3="2156" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAUNTON" b2="230 KV" b3="293T2156" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74010</SeqNum>
    <Name>L230.Ladysmith-LadysmithCT.2089 + LadySmth.T1&amp;T2</Name>
    <LastEdit Timestamp="2025-07-17T16:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMCT" b2="230 KV" b3="208972-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMCT" b2="230 KV" b3="208972-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LADYSMTH" b2="230 KV" b3="2089A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMTH" b2="230 KV" b3="L1T2089" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMTH" b2="230 KV" b3="L2T2089" />
      <ContingencyEquipment Action="X" Type="XF" b1="LADYSMTH" b2="500 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="LADYSMTH" b2="500 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74020</SeqNum>
    <Name>L230.Farmwell-Waxpool.2166</Name>
    <LastEdit Timestamp="2026-02-19T10:41:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMWELL" b2="230 KV" b3="216682" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMWELL" b2="230 KV" b3="FAR-WAXP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMWELL" b2="230 KV" b3="YT2166" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAXPOOL" b2="230 KV" b3="216622-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAXPOOL" b2="230 KV" b3="216622-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74030</SeqNum>
    <Name>L230.Beaumeade-Nivo.2130</Name>
    <LastEdit Timestamp="2024-11-12T15:45:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="21302143" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAUMEAD" b2="230 KV" b3="2130A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="227T2130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="274T2130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="H392" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAUMEAD" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAUMEAD" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NIVO" b2="230 KV" b3="H12T2130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NIVO" b2="230 KV" b3="H34T2130" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74040</SeqNum>
    <Name>L230.Beaumeade-Nivo.2116</Name>
    <LastEdit Timestamp="2024-11-12T15:46:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="21162143" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="211692" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAUMEAD" b2="230 KV" b3="2116A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NIVO" b2="230 KV" b3="H12T2116" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NIVO" b2="230 KV" b3="H34T2116" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74060</SeqNum>
    <Name>L138.Dravosburg-PortPerry-Wilmerding.Z-76</Name>
    <LastEdit Timestamp="2025-07-28T11:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="PERRYCB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PRTPERRY" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRTPERRY" b2="138 KV" b3="PER-DRA" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRTPERRY" b2="138 KV" b3="PER-WIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILMERDI" b2="138 KV" b3="Z-50" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74070</SeqNum>
    <Name>L138.Watson-Oakland.Z-48</Name>
    <LastEdit Timestamp="2025-02-18T09:22:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKL DUQ" b2="138 KV" b3="Z-48" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKL DUQ" b2="138 KV" b3="OAK-WATS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATSON2" b2="138 KV" b3="TIE1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATSON2" b2="138 KV" b3="TIE2-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74080</SeqNum>
    <Name>L138.Carson-Oakland.Z-47</Name>
    <LastEdit Timestamp="2024-07-22T12:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARS DUQ" b2="138 KV" b3="Z-47" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARS DUQ" b2="138 KV" b3="CAR-OAK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKL DUQ" b2="138 KV" b3="Z-47" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74090</SeqNum>
    <Name>L138.Crescent-Valley.Z-82</Name>
    <LastEdit Timestamp="2024-07-22T12:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="138 KV" b3="VALLEY" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRES DUQ" b2="138 KV" b3="CRE-VAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="138 KV" b3="Z-82" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74100</SeqNum>
    <Name>138/69/46.CapitolHill.T1 + 138/46.CapitolHill.T2</Name>
    <LastEdit Timestamp="2025-10-14T18:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CAPITOLH" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="CAPITOLH" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="CAPITOLH" b2="46 KV" b3="1-T" />
      <ContingencyEquipment Action="X" Type="XF" b1="CAPITOLH" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPITOLH" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPITOLH" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPITOLH" b2="46 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPITOLH" b2="46 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPITOLH" b2="138 KV" b3="U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPITOLH" b2="138 KV" b3="V" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74130</SeqNum>
    <Name>L138.NewCarlisle-Pletcher</Name>
    <LastEdit Timestamp="2024-07-22T12:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCARLI" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLETCHER" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLETCHER" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWCARLI" b2="138 KV" b3="NEW-PLE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74140</SeqNum>
    <Name>L230.SnowdenRiver-ColumbiaBC-WildeLake.2320</Name>
    <LastEdit Timestamp="2025-04-22T14:01:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="COLU BC" b2="230 KV" b3="1TR-2320" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU BC" b2="230 KV" b3="2320CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="COLU BC" b2="230 KV" b3="24TR2318" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COLU BC" b2="230 KV" b3="24TR2320" />
      <ContingencyEquipment Action="L" Type="LN" b1="SNOWDENR" b2="230 KV" b3="COL-SNO0" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SNOWDENR" b2="230 KV" b3="230-3HS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="SNOWDENR" b2="13.8 KV" b3="23022303" />
      <ContingencyEquipment Action="CL" Type="CB" b1="SNOWDENR" b2="13.8 KV" b3="23032301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SNOWDENR" b2="230 KV" b3="230TIE" />
      <ContingencyEquipment Action="CL" Type="CB" b1="WILDELAK" b2="13.8 KV" b3="1-2" />
      <ContingencyEquipment Action="CL" Type="CB" b1="WILDELAK" b2="13.8 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WILDELAK" b2="230 KV" b3="1TR-1BUS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WILDELAK" b2="230 KV" b3="1TR-2BUS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WILDELAK" b2="230 KV" b3="2TR-2BUS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WILDELAK" b2="230 KV" b3="3TR-2BUS" />
      <ContingencyEquipment Action="L" Type="LN" b1="WILDELAK" b2="230 KV" b3="COL-WIL0" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74150</SeqNum>
    <Name>L230.HighRidge-SnowdenRiver-Columbia-WildeLk.2318</Name>
    <LastEdit Timestamp="2024-07-25T16:11:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="COLU BC" b2="230 KV" b3="1TR-2318" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COLU BC" b2="230 KV" b3="24TR2318" />
      <ContingencyEquipment Action="L" Type="LN" b1="WILDELAK" b2="230 KV" b3="COL-WIL8" />
      <ContingencyEquipment Action="CL" Type="CB" b1="COLU BC" b2="13.8 KV" b3="LS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="23182338" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="2318CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHRIDG" b2="230 KV" b3="HIG-SNO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SNOWDENR" b2="230 KV" b3="230-1HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SNOWDENR" b2="230 KV" b3="230-2HS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="SNOWDENR" b2="13.8 KV" b3="23022303" />
      <ContingencyEquipment Action="CL" Type="CB" b1="SNOWDENR" b2="13.8 KV" b3="23032301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SNOWDENR" b2="230 KV" b3="230TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="SNOWDENR" b2="230 KV" b3="COL-SNO8" />
      <ContingencyEquipment Action="CL" Type="CB" b1="WILDELAK" b2="13.8 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WILDELAK" b2="230 KV" b3="1TR-1BUS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="WILDELAK" b2="13.8 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WILDELAK" b2="230 KV" b3="2TR-1BUS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WILDELAK" b2="230 KV" b3="3TR-1BUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74160</SeqNum>
    <Name>L138.Strawton-WildcatWindFarm</Name>
    <LastEdit Timestamp="2024-07-25T16:00:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STRAWTON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRAWTON" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STRAWTON" b2="138 KV" b3="STR-WCA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCATWIND" b2="138 KV" b3="52H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCATWIND" b2="138 KV" b3="52H2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74170</SeqNum>
    <Name>L138.Bixby-ShannonRdSwitch-Shannon</Name>
    <LastEdit Timestamp="2025-10-14T18:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="138 KV" b3="113" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="138 KV" b3="114" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHANNON" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIXBY" b2="138 KV" b3="BIX-SHA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHANNON2" b2="138 KV" b3="SC_COOP" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHANNON" b2="138 KV" b3="SHA-SHA2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHANNON2" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74190</SeqNum>
    <Name>L138.Sandhill-WartonHill.1</Name>
    <LastEdit Timestamp="2025-11-17T12:12:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="SANDHIL2" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="H022S8" />
      <ContingencyEquipment Action="L" Type="LN" b1="SANDHIL2" b2="138 KV" b3="SAN-WAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARTONHI" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74200</SeqNum>
    <Name>L138.Sandhill-Crickett-WartonHill.2</Name>
    <LastEdit Timestamp="2024-11-04T13:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRICKETT" b2="138 KV" b3="CRI-WAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRICKETT" b2="138 KV" b3="LOADCNX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRICKETT" b2="138 KV" b3="CRI-SAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARTONHI" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74210</SeqNum>
    <Name>L138.Howard-Shelbyop.2</Name>
    <LastEdit Timestamp="2024-07-25T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOWARD2" b2="138 KV" b3="HOW-SHE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBYOP" b2="138 KV" b3="NS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74220</SeqNum>
    <Name>L138.Osolo-CountyRoad</Name>
    <LastEdit Timestamp="2025-01-10T12:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COUNTYRD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="COUNTYRD" b2="138 KV" b3="COU-OSO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSOLO" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74230</SeqNum>
    <Name>L138.OSU-WestCampus</Name>
    <LastEdit Timestamp="2024-07-25T15:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OSU" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCAMPUS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCAMPUS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="OSU" b2="138 KV" b3="OSU-WCAM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74240</SeqNum>
    <Name>L138.Corner-Porterfield-Shell.88</Name>
    <LastEdit Timestamp="2024-07-25T15:59:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORNER" b2="138 KV" b3="COR-POR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORNER" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CORNER" b2="138 KV" b3="PORTERES" />
      <ContingencyEquipment Action="L" Type="LN" b1="PORTERFI" b2="138 KV" b3="POR-SHE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PORTERFI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHELL" b2="138 KV" b3="PORT DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELL" b2="138 KV" b3="PORTERFI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74260</SeqNum>
    <Name>L138.SouthAnderson-Cadiz-HenryCounty (CIN)</Name>
    <LastEdit Timestamp="2025-09-15T14:04:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="08CADIZ" b2="138 KV" b3="08C-08H" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="08CADIZ" b2="138 KV" b3="1MO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08HENCO" b2="138 KV" b3="13889" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDERSO" b2="138 KV" b3="1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDERSO" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SANDERSO" b2="138 KV" b3="SAN-08C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74270</SeqNum>
    <Name>L138.Fawkes-FawkesTap-LakeReb-FawkesLG</Name>
    <LastEdit Timestamp="2025-07-24T16:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKES" b2="138 KV" b3="CB834" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAWKES" b2="138 KV" b3="SW837" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKESLG" b2="138 KV" b3="B102_724" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKESLG" b2="138 KV" b3="B102_727" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAWKESLG" b2="138 KV" b3="FAW-FAWK" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAWKES" b2="138 KV" b3="FAW-FAWT" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAWKESTP" b2="138 KV" b3="LAK-FAWK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKE_REB" b2="138 KV" b3="B162_704" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74300</SeqNum>
    <Name>L138.Frosburg-TwinRidge + TwinRidge.WF</Name>
    <LastEdit Timestamp="2026-02-10T12:54:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FROSTBU1" b2="138 KV" b3="TWNRDS" />
      <ContingencyEquipment Action="L" Type="LN" b1="FROSTBU1" b2="138 KV" b3="FRO-TWN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINRIDG" b2="138 KV" b3="FROST CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TWINRIDG" b2="34.5 KV" b3="TWNRDGWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="TWINRIDG" b2="138 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74310</SeqNum>
    <Name>L138.Loyalhanna-Bethlen</Name>
    <LastEdit Timestamp="2024-11-04T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHLEN" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHLEN" b2="138 KV" b3="BET-LOY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOYALHAN" b2="138 KV" b3="BETHLEN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOYALHAN" b2="138 KV" b3="BETHLRES" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74320</SeqNum>
    <Name>L138.FortHill-Modaff.1500</Name>
    <LastEdit Timestamp="2024-07-25T15:57:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="70 MODAF" b2="138 KV" b3="150070CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="70 MODAF" b2="138 KV" b3="BTA-B" />
      <ContingencyEquipment Action="L" Type="LN" b1="70 MODAF" b2="138 KV" b3="1500" />
      <ContingencyEquipment Action="OP" Type="CB" b1="80 FORTH" b2="138 KV" b3="150080CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74330</SeqNum>
    <Name>L138.Modaff-W604.1400</Name>
    <LastEdit Timestamp="2024-07-25T15:56:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="70 MODAF" b2="138 KV" b3="1400" />
      <ContingencyEquipment Action="OP" Type="CB" b1="70 MODAF" b2="138 KV" b3="140070CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="70 MODAF" b2="138 KV" b3="BTA-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W604" b2="138 KV" b3="140060CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74340</SeqNum>
    <Name>L138.FortHill-W600.1600</Name>
    <LastEdit Timestamp="2024-07-25T15:55:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="W600" b2="138 KV" b3="1600" />
      <ContingencyEquipment Action="OP" Type="CB" b1="80 FORTH" b2="138 KV" b3="160080CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W600" b2="138 KV" b3="L1600 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74350</SeqNum>
    <Name>L138.W503-W502.3802</Name>
    <LastEdit Timestamp="2024-07-25T15:53:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="W502" b2="138 KV" b3="252-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W503" b2="138 KV" b3="252-2 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="W503" b2="138 KV" b3="252-3 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="W503" b2="138 KV" b3="3802" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74390</SeqNum>
    <Name>L138.Lancaster-11904-Ecogrove-Freeport.11904</Name>
    <LastEdit Timestamp="2025-09-04T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="119 LANC" b2="138 KV" b3="38L11904" />
      <ContingencyEquipment Action="L" Type="LN" b1="11904" b2="138 KV" b3="11904 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="11904" b2="138 KV" b3="11904 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="11904" b2="138 KV" b3="11904 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="11904" b2="138 KV" b3="11904 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="11904" b2="138 KV" b3="11904 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="11904" b2="138 KV" b3="11904 6" />
      <ContingencyEquipment Action="S" Type="SD" b1="11904" b2="138 KV" b3="11904 7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="121 FREE" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="121 FREE" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="121 FREE" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="121 FREE" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="CL" Type="CB" b1="180 LENA" b2="138 KV" b3="BT2-3CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="180 LENA" b2="138 KV" b3="L11904CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="370 ELER" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="370 ELER" b2="138 KV" b3="L11904CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="969 ECOG" b2="138 KV" b3="0455 M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="969 ECOG" b2="34.5 KV" b3="34TR76CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="969 ECOG" b2="34.5 KV" b3="34TR77CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="969 ECOG" b2="34.5 KV" b3="HIGHPTSP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="969 ECOG" b2="34.5 KV" b3="LENAWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="969 ECOG" b2="138 KV" b3="TR76" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="969 ECOG" b2="34.5 KV" b3="TR76 34" />
      <ContingencyEquipment Action="X" Type="XF" b1="969 ECOG" b2="138 KV" b3="TR77" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74400</SeqNum>
    <Name>L138.Kewanee-BishopHill.94301</Name>
    <LastEdit Timestamp="2024-07-25T15:52:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="74 KEWAN" b2="138 KV" b3="L9430 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="74 KEWAN" b2="138 KV" b3="L9430" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOPHI" b2="138 KV" b3="PCB138-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOPHI" b2="138 KV" b3="PCB138-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74410</SeqNum>
    <Name>L138.Webster2-Webster3 (DEOK-EKPC Tie)</Name>
    <LastEdit Timestamp="2024-07-26T13:04:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WEBSTER2" b2="138 KV" b3="962" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEBSTER2" b2="138 KV" b3="967" />
      <ContingencyEquipment Action="L" Type="LN" b1="WEBSTER2" b2="138 KV" b3="WEB-WEB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEBSTER3" b2="138 KV" b3="808" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74420</SeqNum>
    <Name>L138.ElkemMetals-Riverview</Name>
    <LastEdit Timestamp="2024-07-26T11:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELKEM" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELKEM" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RIVERVIE" b2="138 KV" b3="1048MOAB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIE" b2="138 KV" b3="634" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKEM" b2="138 KV" b3="ELK-RIV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74430</SeqNum>
    <Name>L138.Summerfield-Steamtown</Name>
    <LastEdit Timestamp="2024-07-25T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STEAMTOW" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEAMTOW" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMERFI" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="STEAMTOW" b2="138 KV" b3="STE-SUM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74440</SeqNum>
    <Name>230/138.Bergen.T220-4</Name>
    <LastEdit Timestamp="2025-09-16T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="230 KV" b3="220-4XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="138 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="138 KV" b3="SECT 2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74660</SeqNum>
    <Name>L115.NewRoad-Middleburg.49</Name>
    <LastEdit Timestamp="2024-07-30T14:47:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLEBG" b2="115 KV" b3="H172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLEBG" b2="115 KV" b3="H272" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MIDDLEBG" b2="115 KV" b3="H572" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWROAD" b2="115 KV" b3="49" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWROAD" b2="115 KV" b3="49T113" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NEWROAD" b2="115 KV" b3="49XT113" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWROAD" b2="115 KV" b3="L1T49" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74670</SeqNum>
    <Name>L115.EndlessCaverns-Timberville.131</Name>
    <LastEdit Timestamp="2024-07-26T12:45:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="115 KV" b3="13152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="115 KV" b3="XT131" />
      <ContingencyEquipment Action="L" Type="LN" b1="TIMBERVL" b2="115 KV" b3="131" />
      <ContingencyEquipment Action="L" Type="LN" b1="TIMBERVL" b2="115 KV" b3="131B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMBERVL" b2="115 KV" b3="H162CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMBERVL" b2="115 KV" b3="H262" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIMBVLDP" b2="115 KV" b3="TIMBDPZ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74690</SeqNum>
    <Name>L115.ErieSouth-FrenchRd.1</Name>
    <LastEdit Timestamp="2024-11-20T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="115 KV" b3="B61" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FRENCHRD" b2="115 KV" b3="1ERS MOA" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="FRENCHRD" b2="115 KV" b3="BUSS MOA" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERIES" b2="115 KV" b3="ERI-FRE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74700</SeqNum>
    <Name>L115.ErieSouth-FrenchRd.2</Name>
    <LastEdit Timestamp="2024-11-20T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="115 KV" b3="B63" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FRENCHRD" b2="115 KV" b3="2ERS MOA" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="FRENCHRD" b2="115 KV" b3="BUSS MOA" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERIES" b2="115 KV" b3="ERI-FRE2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74730</SeqNum>
    <Name>L115.Northwest-Northwest2</Name>
    <LastEdit Timestamp="2025-08-22T10:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="NORTHWES" b2="115 KV" b3="110574-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="110574CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHWES2" b2="115 KV" b3="574-560" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHWES" b2="115 KV" b3="NOR-NOR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74740</SeqNum>
    <Name>500/230.Lackawanna.T3</Name>
    <LastEdit Timestamp="2025-10-15T16:42:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LACKAWAN" b2="500 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="NMES_T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="500 KV" b3="T3EAST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="500 KV" b3="T3WEST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="TRAN3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74750</SeqNum>
    <Name>500/230.Lackawanna.T4</Name>
    <LastEdit Timestamp="2025-11-10T11:12:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LACKAWAN" b2="500 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="500 KV" b3="TRAN4_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="TRAN4_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="TRAN4_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74770</SeqNum>
    <Name>L500.Hopatcong-Lackawanna.5063</Name>
    <LastEdit Timestamp="2025-06-04T14:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPATCON" b2="500 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPATCON" b2="500 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPATCON" b2="500 KV" b3="HOP-LAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="500 KV" b3="HOPAEAST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="500 KV" b3="HOPAWEST" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74780</SeqNum>
    <Name>L115.Orchards-Westport.110586</Name>
    <LastEdit Timestamp="2024-07-25T15:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="110586" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="586_596" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="110586" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="526-586" />
      <ContingencyEquipment Action="L" Type="LN" b1="ORCHARDS" b2="115 KV" b3="ORC-WES6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74790</SeqNum>
    <Name>L115.NorthHanover-Eisenhower-GittsRun.996</Name>
    <LastEdit Timestamp="2026-01-08T09:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EISENHOW" b2="115 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="EISENHOW" b2="115 KV" b3="EIS-NHA6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EISENHOW" b2="115 KV" b3="T9_LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GITTSRUN" b2="115 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GITTSRUN" b2="115 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="EISENHOW" b2="115 KV" b3="EIS-GIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHANOVER" b2="115 KV" b3="B99632" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74810</SeqNum>
    <Name>L115.Mansfield-TowerHill-Ward</Name>
    <LastEdit Timestamp="2024-07-26T11:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MANS PN" b2="115 KV" b3="MAN-TOW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANS PN" b2="115 KV" b3="TOWERHL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TOWERHIL" b2="115 KV" b3="NO1 TX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WARD" b2="115 KV" b3="1 BANK" />
      <ContingencyEquipment Action="L" Type="LN" b1="TOWERHIL" b2="115 KV" b3="TOW-WAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74820</SeqNum>
    <Name>L115.Garman-Spangler</Name>
    <LastEdit Timestamp="2024-11-21T15:45:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GARMAN" b2="115 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARMAN" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARMAN" b2="115 KV" b3="GAR-SPA" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARMAN" b2="115 KV" b3="GAR-WES" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPANGLER" b2="115 KV" b3="2TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPANGLER" b2="46 KV" b3="2TX_46MO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74830</SeqNum>
    <Name>L69.BasinRoad-NewCastle.6803</Name>
    <LastEdit Timestamp="2025-05-22T13:43:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="L" Type="LN" b1="BASINRD" b2="69 KV" b3="BAS-NEW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="69 KV" b3="68" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74840</SeqNum>
    <Name>L69.BasinRd-WestDPL.6804</Name>
    <LastEdit Timestamp="2024-07-26T13:10:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="69 KV" b3="66" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="69 KV" b3="70" />
      <ContingencyEquipment Action="L" Type="LN" b1="BASINRD" b2="69 KV" b3="BAS-WES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="69 KV" b3="61 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="69 KV" b3="67 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74850</SeqNum>
    <Name>L69.BasinRd-Edgemoor.6805</Name>
    <LastEdit Timestamp="2024-07-26T13:11:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="69 KV" b3="68" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BASINRD" b2="69 KV" b3="6805-L3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="69 KV" b3="69" />
      <ContingencyEquipment Action="L" Type="LN" b1="BASINRD" b2="69 KV" b3="BAS-EDG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="69 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="69 KV" b3="2-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74860</SeqNum>
    <Name>L69.Edgemoor-NewCastle.6801</Name>
    <LastEdit Timestamp="2024-07-26T11:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="69 KV" b3="2-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="69 KV" b3="2-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEMOOR" b2="69 KV" b3="EDG-NEW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74870</SeqNum>
    <Name>L69.Edgemoor-WestDPL</Name>
    <LastEdit Timestamp="2024-12-24T13:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="69 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="69 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="69 KV" b3="63 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="69 KV" b3="64 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEMOOR" b2="69 KV" b3="EDG-WDPL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74880</SeqNum>
    <Name>L69.Worcester-Berlin-Sinepux-Culver-OceanCity.6724</Name>
    <LastEdit Timestamp="2024-07-26T13:01:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BERLINDP" b2="69 KV" b3="BER-SIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERLINDP" b2="69 KV" b3="BERLIN" />
      <ContingencyEquipment Action="L" Type="LN" b1="CULVER" b2="69 KV" b3="CUL-OCC" />
      <ContingencyEquipment Action="L" Type="LN" b1="CULVER" b2="69 KV" b3="CUL-SIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CULVER" b2="69 KV" b3="CULVER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANCTY" b2="69 KV" b3="40" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SINPUX" b2="69 KV" b3="SINPUX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="69 KV" b3="7250" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="69 KV" b3="7280" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERLINDP" b2="69 KV" b3="BER-WOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74900</SeqNum>
    <Name>L69.Cambridge-Jacktown-EastNewMarket.6719</Name>
    <LastEdit Timestamp="2024-07-26T13:07:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIDG" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIDG" b2="69 KV" b3="7140" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIDG" b2="69 KV" b3="7180" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CAMBRIDG" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENEWMARK" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKTOWN" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMBRIDG" b2="69 KV" b3="CAM-JAC" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENEWMARK" b2="69 KV" b3="ENE-JAC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JACKTOWN" b2="69 KV" b3="JACTWN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74910</SeqNum>
    <Name>L230.Camden-CuthbertBlvd.Z-2305</Name>
    <LastEdit Timestamp="2024-07-26T12:58:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDEN" b2="230 KV" b3="2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDEN" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUTHBERT" b2="230 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUTHBERT" b2="230 KV" b3="1-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMDEN" b2="230 KV" b3="CAM-CUTZ" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CUTHBERT" b2="138 KV" b3="CUTHBSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="CUTHBERT" b2="230 KV" b3="SOLAR_XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUTHBERT" b2="230 KV" b3="T40" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74920</SeqNum>
    <Name>L69.Wattsville-Chincoteague.6746</Name>
    <LastEdit Timestamp="2025-05-15T12:51:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHINCOTE" b2="69 KV" b3="LOADT1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHINCOTE" b2="69 KV" b3="LOADT2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHINCOTE" b2="69 KV" b3="T2-H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="69 KV" b3="7620" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="69 KV" b3="7630" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHINCOTE" b2="69 KV" b3="CHI-WAT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WATTSVIL" b2="69 KV" b3="LOADT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74930</SeqNum>
    <Name>L69.Wattsville-WallopsIsland-Chincoteague.6745</Name>
    <LastEdit Timestamp="2025-07-24T16:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHINCOTE" b2="69 KV" b3="T2-H1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHINCOTE" b2="69 KV" b3="CHI-WAL" />
      <ContingencyEquipment Action="L" Type="LN" b1="WALLOPS" b2="69 KV" b3="WAL-WAT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALLOPS" b2="69 KV" b3="WALOPS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="69 KV" b3="7620" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74940</SeqNum>
    <Name>138/69.Scadiz.T1</Name>
    <LastEdit Timestamp="2024-07-26T11:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCADIZ" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCADIZ" b2="138 KV" b3="F CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCADIZ" b2="138 KV" b3="F2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCADIZ" b2="138 KV" b3="T1_XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74950</SeqNum>
    <Name>L69.Church-MasseyRea-Massey.6727</Name>
    <LastEdit Timestamp="2025-01-30T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="7210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="7290" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASSEY" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCH" b2="69 KV" b3="CHU-MAS" />
      <ContingencyEquipment Action="L" Type="LN" b1="MASSEY" b2="69 KV" b3="MAS-MAS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MASSEYRE" b2="69 KV" b3="MASREA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74960</SeqNum>
    <Name>L69.Worcester-OceanPines-NewHope-NSalisbury.6741</Name>
    <LastEdit Timestamp="2025-12-23T10:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWHOPE" b2="69 KV" b3="N-HOPE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSALISBU" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSALISBU" b2="69 KV" b3="67" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NSALISBU" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWHOPE" b2="69 KV" b3="NEW-OCN" />
      <ContingencyEquipment Action="L" Type="LN" b1="OCEANPIN" b2="69 KV" b3="OCN-WOR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OCEANPIN" b2="69 KV" b3="OCNPIN" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWHOPE" b2="69 KV" b3="NEW-WAL" />
      <ContingencyEquipment Action="L" Type="LN" b1="NSALISBU" b2="69 KV" b3="NSA-WAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALSTON" b2="69 KV" b3="WALSTN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="69 KV" b3="7230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="69 KV" b3="7260" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="69 KV" b3="80" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WORCESTE" b2="69 KV" b3="CAP80" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74970</SeqNum>
    <Name>138/69.Motiva.AT2 &amp; L69.Motiva-DelawareCity</Name>
    <LastEdit Timestamp="2025-05-22T12:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="69 KV" b3="63 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTIVA" b2="138 KV" b3="131 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTIVA" b2="138 KV" b3="132 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOTIVA" b2="138 KV" b3="AT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELA DPL" b2="69 KV" b3="DEL-MOT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74980</SeqNum>
    <Name>L69.Reybold-DelawareCity + 138/69.Reybold.AT1</Name>
    <LastEdit Timestamp="2024-07-26T12:44:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="69 KV" b3="64 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="REYBOLD" b2="138 KV" b3="AT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELA DPL" b2="69 KV" b3="DEL-REY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 136" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>74990</SeqNum>
    <Name>L69.Todd-EastNewMarketRea-EastNewMarket.6715</Name>
    <LastEdit Timestamp="2024-07-26T11:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENEWMARK" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENEWMARK" b2="69 KV" b3="ENE-ENE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ENEWMKTR" b2="69 KV" b3="ENMKTR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODD" b2="69 KV" b3="7370" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODD" b2="69 KV" b3="7380" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENEWMKTR" b2="69 KV" b3="ENE-TOD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75000</SeqNum>
    <Name>L69.CedarNeck-Rehoboth.6733</Name>
    <LastEdit Timestamp="2025-05-06T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARNEC" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARNEC" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARNEC" b2="69 KV" b3="CED-REH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REHOBOTH" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REHOBOTH" b2="69 KV" b3="80" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75020</SeqNum>
    <Name>L138.Darrah-EastHuntington</Name>
    <LastEdit Timestamp="2025-01-30T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARRAH" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARRAH" b2="138 KV" b3="DAR-EHUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EHUNTING" b2="138 KV" b3="P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75040</SeqNum>
    <Name>L69.SilversideRoad-Edgemoor.6829</Name>
    <LastEdit Timestamp="2026-02-10T09:05:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="69 KV" b3="1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="69 KV" b3="1-5" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEMOOR" b2="69 KV" b3="EDG-SIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERSI" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERSI" b2="69 KV" b3="65" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75050</SeqNum>
    <Name>L69.Montvale-PearlRiver-Nanuet.491 (RECO-SENY Tie)</Name>
    <LastEdit Timestamp="2024-07-26T13:06:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTVALE" b2="69 KV" b3="491-29-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANUET" b2="69 KV" b3="153-A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANUET" b2="69 KV" b3="T1-53-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEARLRIV" b2="35 KV" b3="491-31-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEARLRIV" b2="69 KV" b3="BK431" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONTVALE" b2="69 KV" b3="MON-PEA" />
      <ContingencyEquipment Action="L" Type="LN" b1="NANUET" b2="69 KV" b3="NAN-PEA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75060</SeqNum>
    <Name>L69.Leon-Leon-Hitchins (AEP-EKPC Tie)</Name>
    <LastEdit Timestamp="2024-07-30T14:59:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HITCHINS" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEONKP" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAHN" b2="69 KV" b3="GRA-LEO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HITCHINS" b2="69 KV" b3="HIT-LEO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEONKP" b2="69 KV" b3="LEO-LEO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEON_EKP" b2="69 KV" b3="CB634" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LEON_EKP" b2="69 KV" b3="SW637" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75070</SeqNum>
    <Name>L69.Falcon-Falcon-MiddleCreek (AEP-EKPC Tie)</Name>
    <LastEdit Timestamp="2024-07-30T14:56:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FALCON" b2="69 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALCON2" b2="69 KV" b3="624" />
      <ContingencyEquipment Action="L" Type="LN" b1="FALCON" b2="69 KV" b3="FAL-20F1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FALCON" b2="46 KV" b3="FAL-MID1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDDLECR" b2="46 KV" b3="MID-PRE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDDLECR" b2="46 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRESTONS" b2="46 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75080</SeqNum>
    <Name>L69.Sturgis-Howe-NLagr-Lagrange (AEP-NIPSCO Tie)</Name>
    <LastEdit Timestamp="2024-07-30T14:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HOWE" b2="69 KV" b3="168 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOWE" b2="69 KV" b3="L1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOWE" b2="69 KV" b3="L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAGRANGE" b2="69 KV" b3="87" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOWE" b2="69 KV" b3="HOW-NLA" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAGRANGE" b2="69 KV" b3="LAG-NLA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="N_LAGR_T" b2="69 KV" b3="NLAG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STURGIS" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="STURGIS" b2="69 KV" b3="STU-HOW1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75090</SeqNum>
    <Name>L69.MorganCounty-MorganCountyEKPC (AEP-EKPC Tie)</Name>
    <LastEdit Timestamp="2025-05-08T18:52:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANCO" b2="69 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANCO" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORGANCO" b2="69 KV" b3="MOR-MOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MRGNC_EK" b2="69 KV" b3="609" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75110</SeqNum>
    <Name>L69.Argentum-Wheelers-NHaverhi (AEP-EKPC Tie)</Name>
    <LastEdit Timestamp="2026-01-09T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGNT_EK" b2="69 KV" b3="CB614" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYSBRA" b2="69 KV" b3="GRA-ARG1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANFURN" b2="69 KV" b3="FRA-GIN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANFURN" b2="69 KV" b3="FRA-KOT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYSBRA" b2="69 KV" b3="GRA-FRA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GINATCRE" b2="69 KV" b3="PLYHGTS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRAYSBRA" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KOTCOAL" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GINATCRE" b2="69 KV" b3="GIN-NHA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHAVERHI" b2="69 KV" b3="P" />
      <ContingencyEquipment Action="L" Type="LN" b1="KOTCOAL" b2="69 KV" b3="KOT-WHE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEELERS" b2="69 KV" b3="W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75120</SeqNum>
    <Name>L69.Clarendon-Rosslyn.122</Name>
    <LastEdit Timestamp="2024-12-31T13:49:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARENDN" b2="69 KV" b3="L3T122" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLARENDN" b2="69 KV" b3="122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSLYN" b2="69 KV" b3="122T178" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSLYN" b2="69 KV" b3="122T180" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75130</SeqNum>
    <Name>L69.Balston-Rosslyn.143+230/69.Balston.TX1</Name>
    <LastEdit Timestamp="2024-12-31T13:49:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BALSTON" b2="230 KV" b3="H182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALSTON" b2="69 KV" b3="L1T143" />
      <ContingencyEquipment Action="X" Type="XF" b1="BALSTON" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BALSTON" b2="69 KV" b3="143" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSLYN" b2="69 KV" b3="143T174" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSLYN" b2="69 KV" b3="143T179" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75150</SeqNum>
    <Name>L69.Brunswick-BrunswickDP-Danieltown.50B</Name>
    <LastEdit Timestamp="2025-05-12T14:33:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRNSWKDP" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWCK" b2="69 KV" b3="5092" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRNSWKDP" b2="69 KV" b3="50B" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRUNSWCK" b2="69 KV" b3="50T132" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRNSWKDP" b2="69 KV" b3="50C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DANLTNDP" b2="69 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75160</SeqNum>
    <Name>L69.Carlisle-Hutching (DEOK-DAYTON Tie)</Name>
    <LastEdit Timestamp="2024-08-01T14:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="08CRLISL" b2="69 KV" b3="08C-HUT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08CRLISL" b2="69 KV" b3="CB624" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="69 KV" b3="AA-11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75170</SeqNum>
    <Name>L69.Thelma-ThelmaEK (AEP-EKPC Tie)</Name>
    <LastEdit Timestamp="2024-08-01T14:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="THELMA" b2="69 KV" b3="THE-THE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMAEK" b2="69 KV" b3="614" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75190</SeqNum>
    <Name>L138.Lemaster-Rosewood-Lee-Dexter</Name>
    <LastEdit Timestamp="2024-08-30T12:46:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEXTER" b2="138 KV" b3="B CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELLIOTT" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELLIOTT" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELLIOTT" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELLIOTT" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELLIOTT" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEXTER" b2="138 KV" b3="DEX-LEEA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEEAEP" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEEAEP" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMASTER" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMASTER" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEMASTER" b2="138 KV" b3="LEM-ROS" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELLIOTT" b2="138 KV" b3="ELL-ROSE" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEEAEP" b2="138 KV" b3="LEE-ROSE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75200</SeqNum>
    <Name>L138.Saltville-Tazewell</Name>
    <LastEdit Timestamp="2024-10-01T16:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SALTVILL" b2="138 KV" b3="SAL-TAZ1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTVILL" b2="138 KV" b3="V" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWELL" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWELL" b2="138 KV" b3="K2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75630</SeqNum>
    <Name>138/69.RiversideIM.T5</Name>
    <LastEdit Timestamp="2025-07-17T15:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSIM" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIVERSIM" b2="138 KV" b3="T5_XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSIM" b2="138 KV" b3="XT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75740</SeqNum>
    <Name>L500.FrontRoyal-WarrenCo.592 + FrontRoyal.CC</Name>
    <LastEdit Timestamp="2024-08-20T07:04:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTROY" b2="500 KV" b3="541T592" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTROY" b2="500 KV" b3="580T592" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTROY" b2="500 KV" b3="G1A42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTROY" b2="500 KV" b3="G1B42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTROY" b2="500 KV" b3="G1C42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTROY" b2="500 KV" b3="G1S42" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRONTROY" b2="21 KV" b3="LD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRONTROY" b2="21 KV" b3="LD2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRONTROY" b2="21 KV" b3="LD3" />
      <ContingencyEquipment Action="S" Type="SD" b1="FRONTROY" b2="500 KV" b3="SD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FRONTROY" b2="21 KV" b3="WARCOCT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FRONTROY" b2="21 KV" b3="WARCOCT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FRONTROY" b2="21 KV" b3="WARCOCT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FRONTROY" b2="19 KV" b3="WARCOST1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75760</SeqNum>
    <Name>L230.ErieSouth-FourMile</Name>
    <LastEdit Timestamp="2024-05-15T09:17:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="4MILEJCT" b2="230 KV" b3="4MI-ERI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="230 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="230 KV" b3="B38" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75770</SeqNum>
    <Name>L230.ErieEast-FourMile</Name>
    <LastEdit Timestamp="2024-08-01T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="4MILEJCT" b2="230 KV" b3="4MIL-ERE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="230 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="230 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEE" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEE" b2="230 KV" b3="B9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75780</SeqNum>
    <Name>230/115.FourMile.T1</Name>
    <LastEdit Timestamp="2025-11-07T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="4MILEJCT" b2="230 KV" b3="1XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="230 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="115 KV" b3="B56" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="115 KV" b3="B82" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75790</SeqNum>
    <Name>L115.CorryEast-FourMile</Name>
    <LastEdit Timestamp="2025-05-13T13:07:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="4MILEJCT" b2="115 KV" b3="4MIL-COR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="115 KV" b3="B76" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="115 KV" b3="B82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRYE" b2="34.5 KV" b3="1TX 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRYE" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CORRYE" b2="115 KV" b3="BK1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75800</SeqNum>
    <Name>L115.BuffaloRoad-FourMile.2</Name>
    <LastEdit Timestamp="2025-03-27T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="4MILEJCT" b2="115 KV" b3="4MIL-BF2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="115 KV" b3="B56" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="115 KV" b3="B62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFALRD" b2="115 KV" b3="B25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75810</SeqNum>
    <Name>L115.ErieSouth-FourMile</Name>
    <LastEdit Timestamp="2024-05-15T09:18:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="4MILEJCT" b2="115 KV" b3="4MI-ERI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="115 KV" b3="B62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="115 KV" b3="B68" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="115 KV" b3="B46" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75820</SeqNum>
    <Name>L115.BuffaloRoad-FourMile.1</Name>
    <LastEdit Timestamp="2025-07-24T16:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="4MILEJCT" b2="115 KV" b3="4MIL-BF1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="115 KV" b3="B68" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4MILEJCT" b2="115 KV" b3="B76" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFALRD" b2="115 KV" b3="B11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75850</SeqNum>
    <Name>230/115.Everetts.TX4</Name>
    <LastEdit Timestamp="2024-08-01T13:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERETTS" b2="230 KV" b3="H4T2014" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERETTS" b2="230 KV" b3="H4T2160" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERETTS" b2="115 KV" b3="L412" />
      <ContingencyEquipment Action="X" Type="XF" b1="EVERETTS" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75890</SeqNum>
    <Name>L69.Derby-Stevensville-HawthorneTap-HickoryCreek</Name>
    <LastEdit Timestamp="2025-05-28T13:48:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DERBY" b2="69 KV" b3="DER-STE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DERBY" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DERBY" b2="69 KV" b3="J2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAWTHOTP" b2="69 KV" b3="HAW-HIC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAWTHOTP" b2="69 KV" b3="HAWTHORN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORYC" b2="69 KV" b3="Q" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAWTHOTP" b2="69 KV" b3="HAW-STE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STEVENSV" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STEVENSV" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75900</SeqNum>
    <Name>138/69.BigSandy.T5 + L69.BigSandy-Burnaugh</Name>
    <LastEdit Timestamp="2024-11-08T13:47:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BIGSANDY" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIGSANDY" b2="69 KV" b3="BIG-BUR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGSANDY" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BIGSANDY" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BIGSANDY" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75920</SeqNum>
    <Name>138/46.CabinCreek.T8</Name>
    <LastEdit Timestamp="2024-08-01T13:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CABINCRE" b2="138 KV" b3=".  8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINCRE" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINCRE" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINCRE" b2="46 KV" b3="V" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75930</SeqNum>
    <Name>138/46.CabinCreek.T9</Name>
    <LastEdit Timestamp="2024-08-01T13:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CABINCRE" b2="138 KV" b3=".  9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINCRE" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINCRE" b2="46 KV" b3="R" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75940</SeqNum>
    <Name>345/138.CantonCentral.TR1</Name>
    <LastEdit Timestamp="2024-08-01T13:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="345 KV" b3="T1_HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTONCE" b2="138 KV" b3="T1_LS" />
      <ContingencyEquipment Action="X" Type="XF" b1="CANTONCE" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75950</SeqNum>
    <Name>L230.EndlessCaverns-Harrisonburg.2134</Name>
    <LastEdit Timestamp="2024-08-01T13:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ENDCAVRN" b2="230 KV" b3="2134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="230 KV" b3="H3T2134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="230 KV" b3="H5T2134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="230 KV" b3="21092134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="230 KV" b3="213492" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>75980</SeqNum>
    <Name>138/46.Chemical.T9</Name>
    <LastEdit Timestamp="2024-05-17T11:19:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="46 KV" b3="AQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="46 KV" b3="AR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHEMICAL" b2="138 KV" b3="T9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="138 KV" b3="XT9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76010</SeqNum>
    <Name>138/4.Conesville.CVD</Name>
    <LastEdit Timestamp="2025-07-24T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="138 KV" b3="5C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="138 KV" b3="5N" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONESVIL" b2="138 KV" b3="CVD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONESVIL" b2="4 KV" b3="CVD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONESVIL" b2="138 KV" b3="LAUX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76020</SeqNum>
    <Name>DTX138.Kankakee.T3</Name>
    <LastEdit Timestamp="2024-11-08T13:40:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CALVERT" b2="138 KV" b3="CAL-KAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANKAKEE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANKAKEE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KANKAKEE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KANKAKEE" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANKAKEE" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76030</SeqNum>
    <Name>L138.Delano-DelanoRoad</Name>
    <LastEdit Timestamp="2024-08-01T13:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELANO" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELANO" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELANO" b2="138 KV" b3="DEL-DEL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DELANORD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76040</SeqNum>
    <Name>L138.Delano-Kenworth</Name>
    <LastEdit Timestamp="2024-08-01T13:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELANO" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELANO" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELANO" b2="138 KV" b3="DEL-KEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENWORTH" b2="13.8 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KENWORTH" b2="13.8 KV" b3="LOAD11" />
      <ContingencyEquipment Action="X" Type="XF" b1="KENWORTH" b2="138 KV" b3="T1_XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76120</SeqNum>
    <Name>L138.Hazelton-Jennings-Finzel</Name>
    <LastEdit Timestamp="2025-07-24T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FINZEL" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINZEL" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="FINZEL" b2="138 KV" b3="FIN-JEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZELTON" b2="138 KV" b3="JENNINGS" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAZELTON" b2="138 KV" b3="HAZ-JEN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JENNINGS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76270</SeqNum>
    <Name>230/115.Tipton.T230-1</Name>
    <LastEdit Timestamp="2024-10-18T13:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TIPTON" b2="230 KV" b3="230-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="230-1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="230 KV" b3="230-1 HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="FB1-1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76280</SeqNum>
    <Name>230/115.Tipton.T230-2</Name>
    <LastEdit Timestamp="2024-10-23T08:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TIPTON" b2="230 KV" b3="230-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="230-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="230 KV" b3="230-2 HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="2TR-609" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76290</SeqNum>
    <Name>230/115.Tipton.T230-3</Name>
    <LastEdit Timestamp="2024-10-22T16:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TIPTON" b2="230 KV" b3="230-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="230 KV" b3="230-3 HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="230-31B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="230-32B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76320</SeqNum>
    <Name>115/34.Wagner.T110-2</Name>
    <LastEdit Timestamp="2024-08-01T13:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WAGNER" b2="115 KV" b3="110-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="110-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="110-2HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="34 KV" b3="110-2LS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGNER" b2="115 KV" b3="535-2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76540</SeqNum>
    <Name>L345.Losantville-TannersCreek</Name>
    <LastEdit Timestamp="2024-08-01T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOSANTVL" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOSANTVL" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOSANTVL" b2="345 KV" b3="LOS-TAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="Q1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="Q2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76560</SeqNum>
    <Name>L138.WestMifflin-Wilson.Z-13</Name>
    <LastEdit Timestamp="2024-08-01T13:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE4-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="WILSON" b2="138 KV" b3="WIL-WMI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMIFFLIN" b2="138 KV" b3="Z-13CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76580</SeqNum>
    <Name>L138.Hickory-RickermanRd</Name>
    <LastEdit Timestamp="2024-08-01T13:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORYC" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICKERMA" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICKERMA" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HICKORYC" b2="138 KV" b3="HIC-RIC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76590</SeqNum>
    <Name>765/345.Vassell.T1</Name>
    <LastEdit Timestamp="2026-06-05T08:24:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="765 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="765 KV" b3="H018H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="345 KV" b3="H018K5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="345 KV" b3="H018K8" />
      <ContingencyEquipment Action="X" Type="XF" b1="VASSELL" b2="765 KV" b3="XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76600</SeqNum>
    <Name>L230.SouthWaterfront-Newport.L-2264</Name>
    <LastEdit Timestamp="2024-12-30T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWP PS" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWP PS" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWP PS" b2="230 KV" b3="NEW-SWAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="230 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="230 KV" b3="SECT 2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76630</SeqNum>
    <Name>345/138.AllenIM.T2</Name>
    <LastEdit Timestamp="2024-08-01T13:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="J2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALLENIM" b2="345 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76640</SeqNum>
    <Name>L138.Bonnyman-SoftShell + 138/69.Bonnyman.T2</Name>
    <LastEdit Timestamp="2024-08-01T13:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BONNYMAN" b2="138 KV" b3="BON-SOF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BONNYMAN" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="X" Type="XF" b1="BONNYMAN" b2="138 KV" b3="XF2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOFTSHEL" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76680</SeqNum>
    <Name>L138.Niles-BerlinLake</Name>
    <LastEdit Timestamp="2024-08-01T13:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERLNLK" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERLNLK" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERLNLK" b2="138 KV" b3="BER-NILE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NILES" b2="138 KV" b3="B9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76690</SeqNum>
    <Name>138/69.BerlinLake.T1</Name>
    <LastEdit Timestamp="2024-08-01T13:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERLNLK" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERLNLK" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERLNLK" b2="69 KV" b3="B28" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERLNLK" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76780</SeqNum>
    <Name>345/138.KanawhaRiver.A</Name>
    <LastEdit Timestamp="2024-10-28T12:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="KANAWHAR" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="345 KV" b3="AA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="345 KV" b3="AA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="138 KV" b3="U" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76790</SeqNum>
    <Name>L230.Aldene-StanleyTerrace.O-2320</Name>
    <LastEdit Timestamp="2025-05-19T15:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALDENE" b2="230 KV" b3="O_2320" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANLEYT" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALDENE" b2="230 KV" b3="ALD-STA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="STANLEYT" b2="230 KV" b3="REACTOR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STANLEYT" b2="230 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76800</SeqNum>
    <Name>L230.Hoboken-Newport.I-2340</Name>
    <LastEdit Timestamp="2025-06-17T14:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOBOKEN" b2="230 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOBOKEN" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWP PS" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWP PS" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOBOKEN" b2="230 KV" b3="HOB-NEWR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76830</SeqNum>
    <Name>L138.Lamberton-HugleRun-WUnion-Sherwood-WaldoRun</Name>
    <LastEdit Timestamp="2025-11-18T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HUGLERUN" b2="138 KV" b3="HUG-WUN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUGLERUN" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMBERTO" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUGLERUN" b2="138 KV" b3="HUG-LAM" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHERWOD" b2="138 KV" b3="SHR-WUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHERWOD" b2="138 KV" b3="SHE-WAL" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WUNION" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WUNION" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76840</SeqNum>
    <Name>L138.GlenFalls-HRChieton-Varner-WaldoRun</Name>
    <LastEdit Timestamp="2025-05-08T18:58:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GLENFALL" b2="138 KV" b3="GLE-HRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENFALL" b2="138 KV" b3="WALDORUN" />
      <ContingencyEquipment Action="L" Type="LN" b1="HREACHIE" b2="138 KV" b3="HRE-VAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HREACHIE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VARNER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="VARNER" b2="138 KV" b3="VAR-WAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76850</SeqNum>
    <Name>L138.Libertyville-Aptakisic.15410</Name>
    <LastEdit Timestamp="2024-08-01T13:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="109 APTA" b2="138 KV" b3="L15410CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="138 KV" b3="L15410CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="15410" b2="138 KV" b3="15410 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="109 APTA" b2="138 KV" b3="15410 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="166 LEIT" b2="138 KV" b3="15410 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="248 LK Z" b2="138 KV" b3="15410 4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="166 LEIT" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="248 LK Z" b2="138 KV" b3="BT2-3 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76860</SeqNum>
    <Name>L230.Milesburg-Moshannon</Name>
    <LastEdit Timestamp="2024-08-01T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILESBUR" b2="230 KV" b3="MOSHANNO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSHANON" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSHANON" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILESBUR" b2="230 KV" b3="MIL-MOS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76870</SeqNum>
    <Name>L345.RiverStartIII-RiverStart-Headwaters</Name>
    <LastEdit Timestamp="2026-04-24T08:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HEADWATR" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HEADWATR" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HEADWATR" b2="34.5 KV" b3="CAP2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HEADWATR" b2="34.5 KV" b3="CAP3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HEADWATR" b2="34.5 KV" b3="CAP4" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEADWATR" b2="345 KV" b3="HEA-RIVE" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HEADWATR" b2="34.5 KV" b3="HEADWTWF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEADWATR" b2="345 KV" b3="U1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERST3" b2="345 KV" b3="52U4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERST3" b2="345 KV" b3="52U5" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIVERST3" b2="345 KV" b3="RI3-RIVE" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="RIVERSTA" b2="34.5 KV" b3="C1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RIVERSTA" b2="34.5 KV" b3="RIVERSSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIVERSTA" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76880</SeqNum>
    <Name>L345.Corridor-Vassell.1</Name>
    <LastEdit Timestamp="2025-10-23T15:31:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="345 KV" b3="303C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="345 KV" b3="303N" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORRIDOR" b2="345 KV" b3="COR-VAS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="345 KV" b3="H007F2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="345 KV" b3="H007F5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76890</SeqNum>
    <Name>L138.Saturn-Sorenson</Name>
    <LastEdit Timestamp="2024-08-01T13:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SATURN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="SATURN" b2="138 KV" b3="SAT-SOR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SATURN" b2="138 KV" b3="XFR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SATURN" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="L1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76920</SeqNum>
    <Name>L230.Dunkirk-SouthRipley [NYISO]</Name>
    <LastEdit Timestamp="2024-08-01T13:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DUNKIRK" b2="230 KV" b3="DUN-SRI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNKIRK" b2="230 KV" b3="R1502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SRIPLEY" b2="230 KV" b3="200" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76930</SeqNum>
    <Name>765/345.Marysville.T2</Name>
    <LastEdit Timestamp="2024-08-01T13:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="765 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="765 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="345 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="345 KV" b3="H1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARYSVI2" b2="765 KV" b3="XF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76940</SeqNum>
    <Name>L138.Hyatt-Kileville</Name>
    <LastEdit Timestamp="2026-01-21T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="101C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="101S" />
      <ContingencyEquipment Action="L" Type="LN" b1="HYATTCS" b2="138 KV" b3="HYA-KILE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KILEVILL" b2="138 KV" b3="H003A5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KILEVILL" b2="138 KV" b3="H003A8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76970</SeqNum>
    <Name>L69.Bridgeman-Cook</Name>
    <LastEdit Timestamp="2024-08-01T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGMAN" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIDGMAN" b2="69 KV" b3="BRI-COO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="69 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76980</SeqNum>
    <Name>L69.Bridgeman-Pletcher</Name>
    <LastEdit Timestamp="2024-08-01T14:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRIDGMAN" b2="69 KV" b3="BRI-PLE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGMAN" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLETCHER" b2="69 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>76990</SeqNum>
    <Name>L69.Bridgeman-Lakeside-ThreeOaks</Name>
    <LastEdit Timestamp="2024-10-31T08:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGMAN" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIDGMAN" b2="69 KV" b3="BRI-LAK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKESDIM" b2="69 KV" b3="LAK-THR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAKESDIM" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THREEOAK" b2="69 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77000</SeqNum>
    <Name>138/69.Pletcher.XFR1</Name>
    <LastEdit Timestamp="2024-11-18T08:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLETCHER" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLETCHER" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLETCHER" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLETCHER" b2="138 KV" b3="XFR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77020</SeqNum>
    <Name>L138.Inland-ClinicHospital.Q11</Name>
    <LastEdit Timestamp="2025-07-08T13:58:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINHOSP" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINHOSP" b2="138 KV" b3="B15" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINHOSP" b2="138 KV" b3="CLI-INL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="138 KV" b3="Q11_JD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77030</SeqNum>
    <Name>L138.Inland-ClinicHospital.Q14</Name>
    <LastEdit Timestamp="2025-07-08T13:58:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINHOSP" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINHOSP" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINHOSP" b2="138 KV" b3="CLI-INL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="138 KV" b3="Q14_JD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77040</SeqNum>
    <Name>L138.Jordan-ClinicHospital.Q14</Name>
    <LastEdit Timestamp="2024-08-01T13:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINHOSP" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINHOSP" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINHOSP" b2="138 KV" b3="CLI-JOR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JORDAN" b2="138 KV" b3="Q14_CHB1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77060</SeqNum>
    <Name>345/138.Crescent.T3</Name>
    <LastEdit Timestamp="2025-05-28T12:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="138 KV" b3="1-5TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="138 KV" b3="2-5TIE" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRES DUQ" b2="345 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="T3-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="345 KV" b3="T3-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77070</SeqNum>
    <Name>L230.Chuckatuck-NewportNews.263 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-29T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNSCH" b2="230 KV" b3="H232" />
      <ContingencyEquipment Action="X" Type="XF" b1="BENNSCH" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENNSCH" b2="34.5 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHUCKATK" b2="230 KV" b3="263A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHUCKATK" b2="230 KV" b3="263T289" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHUCKATK" b2="230 KV" b3="263T290" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENNSCH" b2="230 KV" b3="BEN-COPE" />
      <ContingencyEquipment Action="X" Type="XF" b1="COPELDPK" b2="230 KV" b3="TX1A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COPELDPK" b2="34.5 KV" b3="TX1A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COPELDPK" b2="22 KV" b3="TX2 LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="COPELDPK" b2="230 KV" b3="XF2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NWPORTNW" b2="230 KV" b3="26329M" />
      <ContingencyEquipment Action="L" Type="LN" b1="COPELDPK" b2="230 KV" b3="263C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77080</SeqNum>
    <Name>115/34.BuffaloRoad.T1</Name>
    <LastEdit Timestamp="2024-08-02T13:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BUFFALRD" b2="115 KV" b3="1TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFALRD" b2="115 KV" b3="1TX115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFALRD" b2="35 KV" b3="1TXLSCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77090</SeqNum>
    <Name>115/34.BuffaloRoad.T2</Name>
    <LastEdit Timestamp="2024-08-02T13:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BUFFALRD" b2="115 KV" b3="2TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFALRD" b2="115 KV" b3="2TX115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFALRD" b2="35 KV" b3="2TXLSCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77100</SeqNum>
    <Name>L500.Clifton-Mosby.559A</Name>
    <LastEdit Timestamp="2024-08-02T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTON" b2="500 KV" b3="H1T559" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSBY" b2="500 KV" b3="55972" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLIFTON" b2="500 KV" b3="559A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSBY" b2="500 KV" b3="559T584" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77110</SeqNum>
    <Name>L138.London-NorthTitus</Name>
    <LastEdit Timestamp="2025-12-26T13:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONDONOE" b2="138 KV" b3="A71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONDONOE" b2="138 KV" b3="B165" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONDONOE" b2="138 KV" b3="LON-NTIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTITUS" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTITUS" b2="138 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77120</SeqNum>
    <Name>L115.Oakwood-LittleCreek-Burton.181</Name>
    <LastEdit Timestamp="2024-10-22T16:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BURTON" b2="115 KV" b3="181B" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BURTON" b2="115 KV" b3="27T181" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTON" b2="115 KV" b3="67T181" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURTON" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BURTON" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LITLCREK" b2="115 KV" b3="H132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LITLCREK" b2="115 KV" b3="H232" />
      <ContingencyEquipment Action="X" Type="XF" b1="LITLCREK" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LITLCREK" b2="34.5 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="LITLCREK" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LITLCREK" b2="34.5 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKWOOD" b2="115 KV" b3="18162" />
      <ContingencyEquipment Action="L" Type="LN" b1="LITLCREK" b2="115 KV" b3="181A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77130</SeqNum>
    <Name>L138.London-National-Mitchell-Tangy</Name>
    <LastEdit Timestamp="2025-12-11T14:55:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONDONOE" b2="138 KV" b3="A204" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONDONOE" b2="138 KV" b3="B202" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONDONOE" b2="138 KV" b3="LON-NAT" />
      <ContingencyEquipment Action="L" Type="LN" b1="MITCHELT" b2="138 KV" b3="MIT-NATI" />
      <ContingencyEquipment Action="L" Type="LN" b1="MITCHELT" b2="138 KV" b3="MIT-TANG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MITCHELT" b2="138 KV" b3="MITCH_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATIONL" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATIONL" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NATIONL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NATIONL" b2="138 KV" b3="T2_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="138 KV" b3="B210" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TANGY" b2="138 KV" b3="D202" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77140</SeqNum>
    <Name>L115.Perryman-Harford.110617</Name>
    <LastEdit Timestamp="2024-08-05T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HARFORD" b2="115 KV" b3="110-7" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARFORD" b2="115 KV" b3="110-7CSW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARFORD" b2="115 KV" b3="617SECT" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HARFORD" b2="115 KV" b3="8TR_618" />
      <ContingencyEquipment Action="CL" Type="CB" b1="HARFORD" b2="34.5 KV" b3="DUM7-9" />
      <ContingencyEquipment Action="CL" Type="CB" b1="HARFORD" b2="34.5 KV" b3="DUM8-9" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARFORD" b2="115 KV" b3="HAR-PER7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="110617GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="617_451" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77150</SeqNum>
    <Name>L115.Perryman-Harford.110618</Name>
    <LastEdit Timestamp="2024-08-05T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HARFORD" b2="115 KV" b3="110-9" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARFORD" b2="115 KV" b3="110-9CSW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARFORD" b2="115 KV" b3="618SECT" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HARFORD" b2="115 KV" b3="8TR_618" />
      <ContingencyEquipment Action="CL" Type="CB" b1="HARFORD" b2="34.5 KV" b3="DUM7-9" />
      <ContingencyEquipment Action="CL" Type="CB" b1="HARFORD" b2="34.5 KV" b3="DUM8-9" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARFORD" b2="115 KV" b3="HAR-PER8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="1106181B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="1106182B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77160</SeqNum>
    <Name>L69.Higbee-Marven.0601</Name>
    <LastEdit Timestamp="2024-08-02T14:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MARVENAE" b2="69 KV" b3="HIG-MARV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGBEE" b2="69 KV" b3="OCB F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARVENAE" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARVENAE" b2="69 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77170</SeqNum>
    <Name>L345.Harmon(FE)-Star</Name>
    <LastEdit Timestamp="2024-08-02T14:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="345 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARMONOE" b2="345 KV" b3="HAR-STA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="345 KV" b3="108" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77180</SeqNum>
    <Name>L138.Harmon(FE)-Cloverdale.1</Name>
    <LastEdit Timestamp="2025-11-17T16:07:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLOVEROE" b2="138 KV" b3="A46" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="138 KV" b3="B110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B17" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVEROE" b2="138 KV" b3="CLO-HAR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77190</SeqNum>
    <Name>L138.Harmon(FE)-Cloverdale.2</Name>
    <LastEdit Timestamp="2025-11-17T16:08:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLOVEROE" b2="138 KV" b3="A45" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="138 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVEROE" b2="138 KV" b3="CLO-HAR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77240</SeqNum>
    <Name>345/138.Harmon(FE).TR1</Name>
    <LastEdit Timestamp="2024-08-02T13:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="345 KV" b3="B7" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARMONOE" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77250</SeqNum>
    <Name>345/138.Harmon(FE).TR2</Name>
    <LastEdit Timestamp="2024-08-02T13:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="345 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="345 KV" b3="B8" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARMONOE" b2="345 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77260</SeqNum>
    <Name>138/69.Harmon(FE).TR3</Name>
    <LastEdit Timestamp="2024-08-02T13:53:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARMONOE" b2="69 KV" b3="A106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="69 KV" b3="B25" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARMONOE" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77270</SeqNum>
    <Name>138/69.Harmon(FE).TR4</Name>
    <LastEdit Timestamp="2024-08-02T13:54:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARMONOE" b2="69 KV" b3="A113" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="69 KV" b3="B27" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARMONOE" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77280</SeqNum>
    <Name>L138.Fostoria-RockyFord</Name>
    <LastEdit Timestamp="2025-12-17T19:38:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTORIA" b2="138 KV" b3="FOS-ROCK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="138 KV" b3="M1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="138 KV" b3="M2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKYFOR" b2="138 KV" b3="H021Q2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKYFOR" b2="138 KV" b3="H021U2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77300</SeqNum>
    <Name>L138.Ebersole-FostoriaCentral.1</Name>
    <LastEdit Timestamp="2024-08-02T14:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBERSOLE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBERSOLE" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EBERSOLE" b2="138 KV" b3="EBE-FOS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="138 KV" b3="L1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77310</SeqNum>
    <Name>L138.Ebersole-NorthFindlayCryptoTap-NorthFindlay</Name>
    <LastEdit Timestamp="2025-11-21T15:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBERSOLE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBERSOLE" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EBERSOLE" b2="138 KV" b3="EBE-NFIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NFINDLAY" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="L" Type="LN" b1="NFINDLAY" b2="138 KV" b3="NFI-NFIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NFINDLCR" b2="138 KV" b3="NFINDLY1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77320</SeqNum>
    <Name>L138.Ebersole-Thornwood-FindlayCentral</Name>
    <LastEdit Timestamp="2024-10-11T16:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBERSOLE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBERSOLE" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EBERSOLE" b2="138 KV" b3="EBE-THO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FINDLAYC" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FINDLAYC" b2="138 KV" b3="FIN-THO2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THORNWD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77330</SeqNum>
    <Name>DTX138.Ebersole.XF1</Name>
    <LastEdit Timestamp="2024-08-02T14:03:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBERSOLE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBERSOLE" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EBERSOLE" b2="138 KV" b3="XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77340</SeqNum>
    <Name>230/26.Sewaren.T220-4</Name>
    <LastEdit Timestamp="2025-06-12T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="1-9" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SEWAREN" b2="26 KV" b3="220-4LS" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEWAREN" b2="230 KV" b3="220-4XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77350</SeqNum>
    <Name>230/35.Englishtown.BK5</Name>
    <LastEdit Timestamp="2026-02-10T11:18:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="34.5 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="34.5 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="230 KV" b3="B78" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="230 KV" b3="B81" />
      <ContingencyEquipment Action="X" Type="XF" b1="ENGLISHT" b2="230 KV" b3="BK 5TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77360</SeqNum>
    <Name>230/35.Englishtown.BK6</Name>
    <LastEdit Timestamp="2026-02-10T11:20:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="230 KV" b3="B84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="230 KV" b3="B87" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="34.5 KV" b3="B93" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="34.5 KV" b3="B96" />
      <ContingencyEquipment Action="X" Type="XF" b1="ENGLISHT" b2="230 KV" b3="BK 6 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="34.5 KV" b3="BK6L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77370</SeqNum>
    <Name>Lakewood.NUG.LK</Name>
    <LastEdit Timestamp="2024-08-02T14:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="LAKEWOOD" b2="230 KV" b3="NUG LK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEWOOD" b2="230 KV" b3="NUGGEN C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77400</SeqNum>
    <Name>L345.GlenWillow-Mansfield</Name>
    <LastEdit Timestamp="2024-08-02T14:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENWILL" b2="345 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENWILL" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="57" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="61" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENWILL" b2="345 KV" b3="GLE-MAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77420</SeqNum>
    <Name>L345.EastLake-GlenWillow</Name>
    <LastEdit Timestamp="2025-08-25T13:51:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="345 KV" b3="B734" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="345 KV" b3="B753" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENWILL" b2="345 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENWILL" b2="345 KV" b3="B16" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTLAKE" b2="345 KV" b3="EAS-GLE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77430</SeqNum>
    <Name>L345.GlenWillow-Juniper</Name>
    <LastEdit Timestamp="2025-11-12T10:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENWILL" b2="345 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENWILL" b2="345 KV" b3="B19" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENWILL" b2="345 KV" b3="GLE-JUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIPER" b2="345 KV" b3="B48" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77440</SeqNum>
    <Name>L345.GlenWillow-Perry</Name>
    <LastEdit Timestamp="2025-08-25T13:53:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENWILL" b2="345 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENWILL" b2="345 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENWILL" b2="345 KV" b3="GLE-PER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77450</SeqNum>
    <Name>L345.GlenWillow-Inland</Name>
    <LastEdit Timestamp="2025-04-01T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENWILL" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENWILL" b2="345 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENWILL" b2="345 KV" b3="GLE-INL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="345 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND" b2="345 KV" b3="B18" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77460</SeqNum>
    <Name>L345.Sammis-Toronto</Name>
    <LastEdit Timestamp="2024-08-02T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="345 KV" b3="295" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="345 KV" b3="298" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAMMISFE" b2="345 KV" b3="SAM-TOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="345 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77470</SeqNum>
    <Name>L345.Toronto-WylieRidge</Name>
    <LastEdit Timestamp="2026-03-31T15:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="345 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="TORONTO" b2="345 KV" b3="TOR-WYL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="345 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="345 KV" b3="B23" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77480</SeqNum>
    <Name>345/138.Toronto.T1</Name>
    <LastEdit Timestamp="2024-08-02T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="X" Type="XF" b1="TORONTO" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77490</SeqNum>
    <Name>345/138.Toronto.T2</Name>
    <LastEdit Timestamp="2024-08-02T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="138 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="345 KV" b3="B6" />
      <ContingencyEquipment Action="X" Type="XF" b1="TORONTO" b2="345 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77510</SeqNum>
    <Name>L138.Boardman-Toronto</Name>
    <LastEdit Timestamp="2024-08-02T14:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BOARDMAN" b2="138 KV" b3="A262" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOARDMAN" b2="138 KV" b3="B84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOARDMAN" b2="138 KV" b3="BOA-TOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77520</SeqNum>
    <Name>345/138.SouthMahwah.BK258</Name>
    <LastEdit Timestamp="2024-08-02T13:59:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="258-582X" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMAWA" b2="345 KV" b3="BK258" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="T258-587" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="345 KV" b3="T258_J34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77530</SeqNum>
    <Name>L138.Toronto-Congress-SouthAkron</Name>
    <LastEdit Timestamp="2025-06-26T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CONGRESS" b2="138 KV" b3="CON-TOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONGRESS" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAKRONFE" b2="138 KV" b3="SAK-CON" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONGRESS" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SAKRONFE" b2="138 KV" b3="A370" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRONFE" b2="138 KV" b3="B165" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="138 KV" b3="B13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77540</SeqNum>
    <Name>L345.Niles-Shenango</Name>
    <LastEdit Timestamp="2025-03-24T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NILES" b2="345 KV" b3="B367" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NILES" b2="345 KV" b3="B368" />
      <ContingencyEquipment Action="L" Type="LN" b1="NILES" b2="345 KV" b3="NIL-SHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="345 KV" b3="106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="345 KV" b3="110" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77550</SeqNum>
    <Name>L345.Highland-Niles</Name>
    <LastEdit Timestamp="2024-10-14T14:32:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="124" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLAOE" b2="345 KV" b3="HIG-NIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NILES" b2="345 KV" b3="B368" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NILES" b2="345 KV" b3="B369" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77560</SeqNum>
    <Name>345/138.Niles.T1</Name>
    <LastEdit Timestamp="2024-08-02T13:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NILES" b2="345 KV" b3="B367" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NILES" b2="345 KV" b3="B369" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NILES" b2="138 KV" b3="B370" />
      <ContingencyEquipment Action="X" Type="XF" b1="NILES" b2="345 KV" b3="TR9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77570</SeqNum>
    <Name>230/69.Copperstone.T2</Name>
    <LastEdit Timestamp="2025-01-06T15:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="COPPERST" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="69 KV" b3="T2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="230 KV" b3="TRAN2CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77670</SeqNum>
    <Name>500/138.Breinigsville.TX1</Name>
    <LastEdit Timestamp="2024-10-22T16:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRNGSVIL" b2="138 KV" b3="TRAN1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRNGSVIL" b2="500 KV" b3="TRAN1_" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRNGSVIL" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77680</SeqNum>
    <Name>L500.Alburtis-Breinigsville.5058</Name>
    <LastEdit Timestamp="2024-08-05T16:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBURTIS" b2="500 KV" b3="ALB-BRN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTIS" b2="500 KV" b3="BREI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTIS" b2="500 KV" b3="BREI2BRN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRNGSVIL" b2="500 KV" b3="ALBRTI2E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRNGSVIL" b2="500 KV" b3="ALBRTI2W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77690</SeqNum>
    <Name>L500.Breinigsville-Wescosville.5044</Name>
    <LastEdit Timestamp="2025-06-03T09:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRNGSVIL" b2="500 KV" b3="BRN-WES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRNGSVIL" b2="500 KV" b3="WESCOE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRNGSVIL" b2="500 KV" b3="WESCOW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="500 KV" b3="BREI_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="500 KV" b3="BREI_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77700</SeqNum>
    <Name>500/138.Breinigsville.TX2</Name>
    <LastEdit Timestamp="2024-10-22T16:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRNGSVIL" b2="138 KV" b3="TRAN2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRNGSVIL" b2="500 KV" b3="TRAN2_" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRNGSVIL" b2="500 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77710</SeqNum>
    <Name>L230.Patriot-Saegers + Patriot.U10&amp;U20</Name>
    <LastEdit Timestamp="2025-06-17T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PATRIOT1" b2="230 KV" b3="10ADA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PATRIOT1" b2="230 KV" b3="20ADA" />
      <ContingencyEquipment Action="X" Type="XF" b1="PATRIOT1" b2="230 KV" b3="GSU10" />
      <ContingencyEquipment Action="X" Type="XF" b1="PATRIOT1" b2="230 KV" b3="GSU20" />
      <ContingencyEquipment Action="L" Type="LN" b1="PATRIOT1" b2="230 KV" b3="PAT-SAE" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PATRIOT1" b2="23 KV" b3="PAT10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PATRIOT1" b2="23 KV" b3="PAT20" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PATRIOT1" b2="23 KV" b3="SSL10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PATRIOT1" b2="23 KV" b3="SSL20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAEGERS" b2="230 KV" b3="PAT_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAEGERS" b2="230 KV" b3="PAT_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77720</SeqNum>
    <Name>L230.Clinton-Saegers</Name>
    <LastEdit Timestamp="2024-11-05T14:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLINTON" b2="230 KV" b3="CLI-SAE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON" b2="230 KV" b3="SAEG_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON" b2="230 KV" b3="SAEG_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAEGERS" b2="230 KV" b3="CLINT_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAEGERS" b2="230 KV" b3="CLN_MON" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77730</SeqNum>
    <Name>L230.Elimsport-Saegers</Name>
    <LastEdit Timestamp="2024-08-05T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMSPOR" b2="230 KV" b3="ELM-SAE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMSPOR" b2="230 KV" b3="LYM_SEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMSPOR" b2="230 KV" b3="SAEGERCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAEGERS" b2="230 KV" b3="ELMSPORT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAEGERS" b2="230 KV" b3="ELM_MONT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77740</SeqNum>
    <Name>L230.Montour-Saegers.1</Name>
    <LastEdit Timestamp="2025-11-13T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="MILTSAE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONTOUR" b2="230 KV" b3="MON-SAE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="SAEG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAEGERS" b2="230 KV" b3="CLN_MON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAEGERS" b2="230 KV" b3="MONT_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77750</SeqNum>
    <Name>L230.Montour-Saegers.2</Name>
    <LastEdit Timestamp="2024-05-16T11:24:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="MILTSAE2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONTOUR" b2="230 KV" b3="MON-SAE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="SAEG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAEGERS" b2="230 KV" b3="ELM_MONT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAEGERS" b2="230 KV" b3="MONT_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77790</SeqNum>
    <Name>L230.Acahela-Pocono</Name>
    <LastEdit Timestamp="2024-08-05T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ACAHELA" b2="230 KV" b3="ACA-POC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ACAHELA" b2="230 KV" b3="POCONCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ACAHELA" b2="230 KV" b3="POCOSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCONO" b2="230 KV" b3="ACAH_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCONO" b2="230 KV" b3="ACAH_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77800</SeqNum>
    <Name>L230.Paupack-Pocono</Name>
    <LastEdit Timestamp="2024-08-05T15:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PAUPACK" b2="230 KV" b3="PAU-POC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAUPACK" b2="230 KV" b3="POCONCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAUPACK" b2="230 KV" b3="POCOSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCONO" b2="230 KV" b3="PAUP_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCONO" b2="230 KV" b3="PAUP_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77810</SeqNum>
    <Name>230/69.Pocono.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T13:54:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="POCONO" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCONO" b2="69 KV" b3="1T" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POCONO" b2="230 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77820</SeqNum>
    <Name>230/69.Pocono.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T13:55:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="POCONO" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCONO" b2="69 KV" b3="2T" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POCONO" b2="230 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77830</SeqNum>
    <Name>L230.Susquehanna-SusquehannaT10</Name>
    <LastEdit Timestamp="2024-08-05T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SUSQT10" b2="230 KV" b3="SUS-SUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQT10" b2="230 KV" b3="SUSQ_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQT10" b2="230 KV" b3="SUSQ_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="SUSQ_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77840</SeqNum>
    <Name>L345.155Nelson-942NelsonEC.94201 + NelsonEC</Name>
    <LastEdit Timestamp="2025-10-29T10:27:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="942 NELS" b2="345 KV" b3="94201" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT1-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="942 NELS" b2="345 KV" b3="5241" />
      <ContingencyEquipment Action="OP" Type="CB" b1="942 NELS" b2="345 KV" b3="5242" />
      <ContingencyEquipment Action="OP" Type="CB" b1="942 NELS" b2="345 KV" b3="5243" />
      <ContingencyEquipment Action="OP" Type="CB" b1="942 NELS" b2="345 KV" b3="5244" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="942 NELS" b2="13.8 KV" b3="AUX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="942 NELS" b2="13.8 KV" b3="AUX2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="942 NELS" b2="18 KV" b3="GT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="942 NELS" b2="18 KV" b3="GT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="942 NELS" b2="18 KV" b3="GT3CT_1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="942 NELS" b2="18 KV" b3="GT4CT_1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="942 NELS" b2="13.8 KV" b3="SS1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="942 NELS" b2="13.8 KV" b3="SS2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="942 NELS" b2="18 KV" b3="SS3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="942 NELS" b2="13.8 KV" b3="ST1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="942 NELS" b2="13.8 KV" b3="ST2" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="345 KV" b3="TR1GSU-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="18 KV" b3="TR1GSU-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="13.8 KV" b3="TR1GSU-T" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="345 KV" b3="TR2GSU-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="18 KV" b3="TR2GSU-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="13.8 KV" b3="TR2GSU-T" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="345 KV" b3="TR3GSU-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="345 KV" b3="TR4GSU-P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77850</SeqNum>
    <Name>942NelsonEC.ST/GT1</Name>
    <LastEdit Timestamp="2025-10-17T12:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="942 NELS" b2="345 KV" b3="5241" />
      <ContingencyEquipment Action="OP" Type="CB" b1="942 NELS" b2="18 KV" b3="52CG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="942 NELS" b2="13.8 KV" b3="52SG1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="942 NELS" b2="13.8 KV" b3="AUX1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="942 NELS" b2="18 KV" b3="GT1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="942 NELS" b2="13.8 KV" b3="SS1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="942 NELS" b2="13.8 KV" b3="ST1" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="345 KV" b3="TR1GSU-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="18 KV" b3="TR1GSU-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="13.8 KV" b3="TR1GSU-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77860</SeqNum>
    <Name>942NelsonEC.ST/GT2</Name>
    <LastEdit Timestamp="2025-10-17T12:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="942 NELS" b2="345 KV" b3="5242" />
      <ContingencyEquipment Action="OP" Type="CB" b1="942 NELS" b2="18 KV" b3="52CG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="942 NELS" b2="13.8 KV" b3="52SG2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="942 NELS" b2="13.8 KV" b3="AUX2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="942 NELS" b2="18 KV" b3="GT2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="942 NELS" b2="13.8 KV" b3="SS2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="942 NELS" b2="13.8 KV" b3="ST2" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="345 KV" b3="TR2GSU-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="18 KV" b3="TR2GSU-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="13.8 KV" b3="TR2GSU-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77870</SeqNum>
    <Name>345/138.MuskingumRiver.T-D</Name>
    <LastEdit Timestamp="2024-08-05T15:36:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="138 KV" b3="HQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="138 KV" b3="HR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SW" />
      <ContingencyEquipment Action="X" Type="XF" b1="MUSKING2" b2="345 KV" b3="XFMR D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77890</SeqNum>
    <Name>345/138.Vassell.T3</Name>
    <LastEdit Timestamp="2025-10-21T13:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="345 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="345 KV" b3="L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="X" Type="XF" b1="VASSELL" b2="345 KV" b3="XF3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77900</SeqNum>
    <Name>L138.Vassell-Delaware</Name>
    <LastEdit Timestamp="2024-08-05T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELAWARE" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="138 KV" b3="AC2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELAWARE" b2="138 KV" b3="DEL-VAS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77910</SeqNum>
    <Name>L345.AllenJunction-Midway</Name>
    <LastEdit Timestamp="2024-08-05T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENJUN" b2="345 KV" b3="ALL-MIDW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="345 KV" b3="B42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="345 KV" b3="B46" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="345 KV" b3="B34534" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="345 KV" b3="B34536" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77930</SeqNum>
    <Name>L345.Dowling-Fulton</Name>
    <LastEdit Timestamp="2024-08-05T16:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOWLING" b2="345 KV" b3="DOW-FULT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULTONFE" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FULTONFE" b2="345 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77940</SeqNum>
    <Name>L345.Dowling-Lemoyne</Name>
    <LastEdit Timestamp="2024-08-05T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOWLING" b2="345 KV" b3="DOW-LEM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="345 KV" b3="B34504" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77950</SeqNum>
    <Name>345/138.Dowling.T1</Name>
    <LastEdit Timestamp="2025-11-10T10:11:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOWLING" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77960</SeqNum>
    <Name>L138.Dowling-Midway</Name>
    <LastEdit Timestamp="2024-08-05T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOWLING" b2="138 KV" b3="DOW-MIDW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13301" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77970</SeqNum>
    <Name>L138.Dowling-HomeDepot-Lemoyne</Name>
    <LastEdit Timestamp="2025-11-10T10:13:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="138 KV" b3="B70" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="138 KV" b3="B80" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOWLING" b2="138 KV" b3="DOW-HOM" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOMEDEPT" b2="138 KV" b3="HOM-LEM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOMEDEPT" b2="138 KV" b3="HOMEDEPT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMOYNE2" b2="138 KV" b3="13216" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77980</SeqNum>
    <Name>L138.ChryslerToledo-FirstSolar-LimeCity-Dowling</Name>
    <LastEdit Timestamp="2025-11-10T10:14:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02LIMECT" b2="138 KV" b3="02L-FST" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="02LIMECT" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="02LIMECT" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LIMECT" b2="138 KV" b3="CS18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LIMECT" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LIMECT" b2="138 KV" b3="CS38" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LIMECT" b2="138 KV" b3="CS46" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02LIMECT" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02LIMECT" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRYSLE2" b2="138 KV" b3="13290" />
      <ContingencyEquipment Action="L" Type="LN" b1="FSTSOLAR" b2="138 KV" b3="FST-CHR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="138 KV" b3="B110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="138 KV" b3="B120" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOWLING" b2="138 KV" b3="DOW-LIME" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FSTSOLAR" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FSTSOLAR" b2="138 KV" b3="CS4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FSTSOLAR" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FSTSOLAR" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FSTSOLAR" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>77990</SeqNum>
    <Name>L138.Dowling-Delafoil-LevisPark</Name>
    <LastEdit Timestamp="2026-02-06T12:18:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02FIVEPT" b2="138 KV" b3="CS13347" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02FIVEPT" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02OILEVS" b2="138 KV" b3="02O-DEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02OILEVS" b2="138 KV" b3="B13335" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELAFOIL" b2="138 KV" b3="02F-DEL" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELAFOIL" b2="138 KV" b3="DEL-DOWL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DELAFOIL" b2="138 KV" b3="LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="138 KV" b3="B100" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78020</SeqNum>
    <Name>L345.AllenJunction-Morocco (ITC) Tie</Name>
    <LastEdit Timestamp="2025-03-28T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENJUN" b2="345 KV" b3="ALL-MORO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="345 KV" b3="B34531" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="345 KV" b3="B34532" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOROCCO" b2="345 KV" b3="34F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOROCCO" b2="345 KV" b3="36H9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78030</SeqNum>
    <Name>L345.Lulu Tap(Morocco-Lulu-Milan-Monroe)</Name>
    <LastEdit Timestamp="2024-08-06T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LULU" b2="345 KV" b3="LUL-MIL" />
      <ContingencyEquipment Action="L" Type="LN" b1="LULU" b2="345 KV" b3="LUL-MON" />
      <ContingencyEquipment Action="L" Type="LN" b1="LULU" b2="345 KV" b3="LUL-MORO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILAN" b2="345 KV" b3="CM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILAN" b2="345 KV" b3="CT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONROE" b2="345 KV" b3="MF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONROE" b2="345 KV" b3="MM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOROCCO" b2="345 KV" b3="34H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOROCCO" b2="345 KV" b3="36H9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78050</SeqNum>
    <Name>L138.Brookside-Nottingham</Name>
    <LastEdit Timestamp="2024-11-21T14:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKSID" b2="138 KV" b3="A97" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSID" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKSID" b2="138 KV" b3="BRO-NOT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="L5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78060</SeqNum>
    <Name>L138.Nottingham-Reedsburgh-Longview</Name>
    <LastEdit Timestamp="2024-08-05T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONGVIOE" b2="138 KV" b3="A125" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGVIOE" b2="138 KV" b3="B68" />
      <ContingencyEquipment Action="L" Type="LN" b1="REEDSBUR" b2="138 KV" b3="REE-LON1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="K5" />
      <ContingencyEquipment Action="L" Type="LN" b1="NOTINGHA" b2="138 KV" b3="NOT-REE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REEDSBUR" b2="138 KV" b3="LDRE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78110</SeqNum>
    <Name>L138.154Libertyville-15417-109Aptakisic.15417</Name>
    <LastEdit Timestamp="2025-06-24T10:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="109 APTA" b2="138 KV" b3="L15417CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="154 LIBE" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="15417" b2="138 KV" b3="15417 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="109 APTA" b2="138 KV" b3="15417 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="166 LEIT" b2="138 KV" b3="15417 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="248 LK Z" b2="138 KV" b3="15417 4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="166 LEIT" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="166 LEIT" b2="138 KV" b3="L15417CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="248 LK Z" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="248 LK Z" b2="138 KV" b3="L15417CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78120</SeqNum>
    <Name>L138.Willey-Fairfield.3886</Name>
    <LastEdit Timestamp="2024-10-11T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="08FRFLD1" b2="138 KV" b3="08L-WILL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08FRFLD1" b2="138 KV" b3="886" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08FRFLD1" b2="138 KV" b3="888" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08FRFLD1" b2="138 KV" b3="BK3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLEY" b2="138 KV" b3="942" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLEY" b2="138 KV" b3="CB842" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78140</SeqNum>
    <Name>L230.Sayreville-WoodbridgeEC + WoodbridgeEC.CC</Name>
    <LastEdit Timestamp="2025-06-26T11:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="B155" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAYREVIL" b2="230 KV" b3="SAY-WOOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODBRDG" b2="230 KV" b3="52-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODBRDG" b2="230 KV" b3="52-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODBRDG" b2="230 KV" b3="52-3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODBRDG" b2="18 KV" b3="CT-1A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODBRDG" b2="18 KV" b3="CT-1B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODBRDG" b2="18 KV" b3="S1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODBRDG" b2="18 KV" b3="SS-1A LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODBRDG" b2="18 KV" b3="SS-1B LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODBRDG" b2="230 KV" b3="T1A" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODBRDG" b2="230 KV" b3="T1B" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODBRDG" b2="230 KV" b3="TS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78150</SeqNum>
    <Name>L230.Gloucest-Camden.Y-2304 + 230/26.Glcstr.220-2</Name>
    <LastEdit Timestamp="2024-08-12T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDEN" b2="230 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMDEN" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMDEN" b2="230 KV" b3="CAM-GLOY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="2-7" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLOUCEST" b2="230 KV" b3="220-2 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="220-2CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78210</SeqNum>
    <Name>230/69.Gloucester.220-6TR</Name>
    <LastEdit Timestamp="2025-08-01T13:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="69 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="220-6CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLOUCEST" b2="230 KV" b3="220-6TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="69 KV" b3="3-4A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78220</SeqNum>
    <Name>L230.Shawboro-Aydlett.2136</Name>
    <LastEdit Timestamp="2024-08-06T11:33:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="AYDLETT" b2="230 KV" b3="20732136" />
      <ContingencyEquipment Action="L" Type="LN" b1="AYDLETT" b2="230 KV" b3="2136A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AYDLETT" b2="230 KV" b3="H132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AYDLETT" b2="230 KV" b3="H232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWBORO" b2="230 KV" b3="20212136" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWBORO" b2="230 KV" b3="269T2136" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78270</SeqNum>
    <Name>L345.Bixby-OhioCentral</Name>
    <LastEdit Timestamp="2024-08-05T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BIXBY" b2="345 KV" b3="BIX-OHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="345 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="345 KV" b3="E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="345 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="345 KV" b3="L2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78280</SeqNum>
    <Name>L345.Conesville-OhioCentral</Name>
    <LastEdit Timestamp="2024-08-05T16:02:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="345 KV" b3="303C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="345 KV" b3="303S" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONESVIL" b2="345 KV" b3="CON-OHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="345 KV" b3="K2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78300</SeqNum>
    <Name>L345.Lisle-Lombard.10322</Name>
    <LastEdit Timestamp="2024-12-10T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="345 KV" b3="L10322CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="103 LISL" b2="345 KV" b3="10322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="345 KV" b3="L10322CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78360</SeqNum>
    <Name>MtStorm.SVC</Name>
    <LastEdit Timestamp="2025-02-20T13:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MTSTORM4" b2="500 KV" b3="BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MTSTORM4" b2="500 KV" b3="BUCK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MTSTORM4" b2="500 KV" b3="SV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="SV1TB3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="SV1TB4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78370</SeqNum>
    <Name>500.Mt.Storm.Cap.SC1</Name>
    <LastEdit Timestamp="2024-10-17T15:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="MTSTORM4" b2="500 KV" b3="SC1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78440</SeqNum>
    <Name>L230.Winfall-SHertford-WAlbemarle-Pembroke.2092</Name>
    <LastEdit Timestamp="2024-10-16T11:26:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEMBROKE" b2="230 KV" b3="20922131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEMBROKE" b2="230 KV" b3="20922293" />
      <ContingencyEquipment Action="L" Type="LN" b1="PEMBROKE" b2="230 KV" b3="PEM-WEST" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHERTFOR" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERTFOR" b2="230 KV" b3="TX1CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHERTFOR" b2="230 KV" b3="TX1_NCE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTALDP" b2="230 KV" b3="DP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHERTFOR" b2="230 KV" b3="SHE-WES1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINFALL" b2="230 KV" b3="209222-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINFALL" b2="230 KV" b3="209222-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHERTFOR" b2="230 KV" b3="SHE-WINF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78500</SeqNum>
    <Name>L230.Deptford-Gloucester.V-2274</Name>
    <LastEdit Timestamp="2025-01-21T13:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DEPTFORD" b2="230 KV" b3="DEP-GLOV" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="DEPTFORD" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEPTFORD" b2="230 KV" b3="SECT1-2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="DEPTFORD" b2="230 KV" b3="TRAN3-4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DEPTFORD" b2="230 KV" b3="TRANT-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DEPTFORD" b2="230 KV" b3="TRANT-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="2-5" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLOUCEST" b2="230 KV" b3="220-1 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="220-1CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="GLOUCEST" b2="26 KV" b3="R1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78510</SeqNum>
    <Name>230/115.Gordonsville.TX3 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-04-22T11:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GORDONSV" b2="230 KV" b3="H384M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONSV" b2="115 KV" b3="L382" />
      <ContingencyEquipment Action="X" Type="XF" b1="GORDONSV" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78590</SeqNum>
    <Name>955River.CT1</Name>
    <LastEdit Timestamp="2026-04-06T09:06:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="955 RIVE" b2="138 KV" b3="95501 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="955 RIVE" b2="138 KV" b3="L95501CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="955 RIVE" b2="16 KV" b3="LAUXTR1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="955 RIVE" b2="16 KV" b3="RV-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="955 RIVE" b2="138 KV" b3="TR11 16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78600</SeqNum>
    <Name>955River.CT2</Name>
    <LastEdit Timestamp="2026-04-06T08:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="955 RIVE" b2="138 KV" b3="95502 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="955 RIVE" b2="138 KV" b3="L95502CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="955 RIVE" b2="16 KV" b3="RV-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="955 RIVE" b2="138 KV" b3="TR12 16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78610</SeqNum>
    <Name>138/69.Jackson.T1</Name>
    <LastEdit Timestamp="2024-08-05T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PL" b2="138 KV" b3="MONR CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PL" b2="138 KV" b3="MONR_2CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="JACK PL" b2="138 KV" b3="TRAN 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PL" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78620</SeqNum>
    <Name>138/69.Jackson.T2</Name>
    <LastEdit Timestamp="2024-08-05T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PL" b2="138 KV" b3="SIEG CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PL" b2="138 KV" b3="SIEG_2CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="JACK PL" b2="138 KV" b3="TRAN 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PL" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78640</SeqNum>
    <Name>ArchbaldTap.PEI.U1&amp;U5&amp;U6</Name>
    <LastEdit Timestamp="2024-08-05T15:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARCHBTAP" b2="69 KV" b3="GEN1 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ARCHBTAP" b2="69 KV" b3="GEN1 GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ARCHBTAP" b2="13 KV" b3="PEI 1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ARCHBTAP" b2="13 KV" b3="PEI 5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ARCHBTAP" b2="13 KV" b3="PEI 6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78650</SeqNum>
    <Name>L69.Jenkins-Owens-EMountain-BearCrk.1 + BearCrk.WF</Name>
    <LastEdit Timestamp="2025-08-04T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAR CRK" b2="69 KV" b3="52U" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAR CRK" b2="69 KV" b3="BEA-EMO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAR CRK" b2="69 KV" b3="BEAR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BEAR CRK" b2="35 KV" b3="BEARCRK" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAR CRK" b2="69 KV" b3="HARWOOD1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BEAR CRK" b2="69 KV" b3="TAP2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAR CRK" b2="69 KV" b3="XFMR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTMNTN" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JENKINS" b2="69 KV" b3="JEN-OWE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="PALO1_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="PALO1_S" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OWENSILL" b2="69 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTMNTN" b2="69 KV" b3="EAS-OWE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OWENSILL" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78660</SeqNum>
    <Name>WallenPaupack.HYDRO </Name>
    <LastEdit Timestamp="2026-03-05T12:55:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WLPK_GEN" b2="69 KV" b3="GEN_BK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLPK_GEN" b2="69 KV" b3="GEN_BK2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WLPK_GEN" b2="69 KV" b3="WLPK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78670</SeqNum>
    <Name>Frackville.SCEN</Name>
    <LastEdit Timestamp="2024-08-05T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="FRACKVIL" b2="69 KV" b3="SCENUG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="SECNUGGE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78680</SeqNum>
    <Name>Frackville.GLBT</Name>
    <LastEdit Timestamp="2025-07-31T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FRACKVIL" b2="69 KV" b3="2368" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FRACKVIL" b2="69 KV" b3="GLBNUG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78690</SeqNum>
    <Name>L69.FaceRock-Holtwood.697Span + Holtwood.U18&amp;U19</Name>
    <LastEdit Timestamp="2024-08-06T11:13:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="697SPANS" />
      <ContingencyEquipment Action="S" Type="SD" b1="FACEROCK" b2="69 KV" b3="697_SD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FACEROCK" b2="13 KV" b3="HOLT18" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FACEROCK" b2="13 KV" b3="HOLT19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="MA16697T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FACEROCK" b2="13 KV" b3="SS3LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="13 KV" b3="TL4C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="13 KV" b3="TL4D" />
      <ContingencyEquipment Action="X" Type="XF" b1="FACEROCK" b2="69 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78700</SeqNum>
    <Name>L69.FaceRock-Holtwood.696Span + Holtwood.U6-U10&amp;13</Name>
    <LastEdit Timestamp="2024-08-06T11:23:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="FACEROCK" b2="69 KV" b3="696_SD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="696_SPAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="13 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FACEROCK" b2="69 KV" b3="DUMGEN2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FACEROCK" b2="13 KV" b3="HOLT10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FACEROCK" b2="13 KV" b3="HOLT13" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FACEROCK" b2="13 KV" b3="HOLT6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FACEROCK" b2="13 KV" b3="HOLT7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FACEROCK" b2="13 KV" b3="HOLT8" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FACEROCK" b2="13 KV" b3="HOLT9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="MLW2-696" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FACEROCK" b2="13 KV" b3="SS2LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="13 KV" b3="TL2-1_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="13 KV" b3="TL2-3_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="13 KV" b3="TL3" />
      <ContingencyEquipment Action="X" Type="XF" b1="FACEROCK" b2="69 KV" b3="TR2" />
      <ContingencyEquipment Action="X" Type="XF" b1="FACEROCK" b2="69 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78710</SeqNum>
    <Name>L69.FaceRock-Holtwood.695Span + Holtwood.U1-U5&amp;U11</Name>
    <LastEdit Timestamp="2024-08-06T11:27:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="695SPANN" />
      <ContingencyEquipment Action="S" Type="SD" b1="FACEROCK" b2="69 KV" b3="695_SD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="13 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FACEROCK" b2="69 KV" b3="DUMGEN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="FIFO695T" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FACEROCK" b2="13 KV" b3="HOLT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FACEROCK" b2="13 KV" b3="HOLT11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FACEROCK" b2="13 KV" b3="HOLT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FACEROCK" b2="13 KV" b3="HOLT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FACEROCK" b2="13 KV" b3="HOLT4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FACEROCK" b2="13 KV" b3="HOLT5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FACEROCK" b2="13 KV" b3="SS1LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="13 KV" b3="TL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="13 KV" b3="TL2-1_CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FACEROCK" b2="69 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78720</SeqNum>
    <Name>L69.FaceRock-Millwood.1</Name>
    <LastEdit Timestamp="2025-11-13T13:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FACEROCK" b2="69 KV" b3="FAC-MIL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="MLWD1_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLWDPL" b2="69 KV" b3="BUSTIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLWDPL" b2="69 KV" b3="FACER1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78730</SeqNum>
    <Name>L69.FaceRock-MtNebo-Millwood.2</Name>
    <LastEdit Timestamp="2024-10-11T16:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MTNEBO" b2="69 KV" b3="FAC-MTNB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="MLW2-696" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="MLWD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLWDPL" b2="69 KV" b3="BUSTIE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLWDPL" b2="69 KV" b3="FACER2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTNEBO" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLWDPL" b2="69 KV" b3="MIL2-MNB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78740</SeqNum>
    <Name>L69.FaceRock-Manor</Name>
    <LastEdit Timestamp="2024-08-06T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FACEROCK" b2="69 KV" b3="FAC-MAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="MA16697T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="MANO16NB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="FARO_16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78750</SeqNum>
    <Name>L500.Juniata-Sunbury.5046</Name>
    <LastEdit Timestamp="2025-01-17T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIATA" b2="500 KV" b3="JUN-SUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="500 KV" b3="SUNB_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="500 KV" b3="SUNB_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="500 KV" b3="JUN_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="500 KV" b3="JUN_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78760</SeqNum>
    <Name>L500.Sunbury-Susquehanna.5045</Name>
    <LastEdit Timestamp="2025-07-25T16:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="500 KV" b3="SUSQ2N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="500 KV" b3="SUSQ2S" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUNBURY" b2="500 KV" b3="SUN-SUS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="500 KV" b3="SUNB2TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="500 KV" b3="SUNB_2-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78770</SeqNum>
    <Name>500/230.Sunbury.T24</Name>
    <LastEdit Timestamp="2024-11-22T10:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SUNBURY" b2="500 KV" b3="24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="TRAN24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="500 KV" b3="TRAN24" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78780</SeqNum>
    <Name>L345.BiersRun-Marquis</Name>
    <LastEdit Timestamp="2024-08-06T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIERSRUN" b2="345 KV" b3="BIE-MAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="345 KV" b3="D1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78790</SeqNum>
    <Name>L345.BiersRun-Bixby</Name>
    <LastEdit Timestamp="2024-08-06T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIERSRUN" b2="345 KV" b3="BIE-BIX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="345 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="345 KV" b3="C1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78820</SeqNum>
    <Name>L138.BiersRun-Lutz</Name>
    <LastEdit Timestamp="2025-09-04T14:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BIERSRUN" b2="138 KV" b3="BIE-LUTZ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="138 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUTZ" b2="138 KV" b3="H002K8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUTZ" b2="138 KV" b3="H002L5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78830</SeqNum>
    <Name>L345.HyattCS-WMillersport</Name>
    <LastEdit Timestamp="2024-08-06T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HYATTCS" b2="345 KV" b3="HYA-WMI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="345 KV" b3="M2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78840</SeqNum>
    <Name>L345.HyattCS-Marysville</Name>
    <LastEdit Timestamp="2024-08-06T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="K1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="345 KV" b3="L1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="345 KV" b3="L2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HYATTCS" b2="345 KV" b3="MAR-HYA2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78850</SeqNum>
    <Name>L345.Cook-Segreto</Name>
    <LastEdit Timestamp="2024-08-06T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COOK" b2="345 KV" b3="COO-SEG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="N2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEGRETO" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEGRETO" b2="345 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78860</SeqNum>
    <Name>L345.BentonHarbor-Segreto</Name>
    <LastEdit Timestamp="2025-11-10T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENTONHA" b2="345 KV" b3="BEN-SEG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEGRETO" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEGRETO" b2="345 KV" b3="A2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78870</SeqNum>
    <Name>L345.Palisades-Segreto.1</Name>
    <LastEdit Timestamp="2024-08-06T11:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="25H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="25R8" />
      <ContingencyEquipment Action="L" Type="LN" b1="PALISAD2" b2="345 KV" b3="PAL-SEG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEGRETO" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEGRETO" b2="345 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78880</SeqNum>
    <Name>L345.Palisades-Segreto.2</Name>
    <LastEdit Timestamp="2026-02-27T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="27F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="27H9" />
      <ContingencyEquipment Action="L" Type="LN" b1="PALISAD2" b2="345 KV" b3="PAL-SEG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEGRETO" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEGRETO" b2="345 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78890</SeqNum>
    <Name>L765.Marysville-Sorenson</Name>
    <LastEdit Timestamp="2024-08-06T11:04:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="765 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARYSVI2" b2="765 KV" b3="MAR-SOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="765 KV" b3="RB2_CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MARYSVI2" b2="765 KV" b3="RSCA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MARYSVI2" b2="765 KV" b3="RSCB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MARYSVI2" b2="765 KV" b3="RSCC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="765 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="765 KV" b3="K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="765 KV" b3="RK2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SORENSON" b2="765 KV" b3="RX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78910</SeqNum>
    <Name>765/345.Sorenson.T3</Name>
    <LastEdit Timestamp="2024-08-06T10:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="765 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="765 KV" b3="H1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SORENSON" b2="765 KV" b3="XF3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>78920</SeqNum>
    <Name>138/69.Brues.TX5</Name>
    <LastEdit Timestamp="2024-08-06T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUES" b2="69 KV" b3="E CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUES" b2="138 KV" b3="TX5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUES" b2="138 KV" b3="XT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79000</SeqNum>
    <Name>L138.BentonHarbor-WestSt-EWatervilet-Hartford</Name>
    <LastEdit Timestamp="2024-08-06T11:36:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BENTONHA" b2="138 KV" b3="BEN-WES1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EWATERVT" b2="138 KV" b3="EAS-HAR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EWATERVT" b2="138 KV" b3="EWATRVSP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EWATERVT" b2="138 KV" b3="LOADT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARTFORD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="EWATERVT" b2="138 KV" b3="EAS-WES" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WESTSTRE" b2="138 KV" b3="ORCHDHLF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTSTRE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79010</SeqNum>
    <Name>L230.Forest-SquabHollow</Name>
    <LastEdit Timestamp="2024-06-22T10:05:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOREST" b2="230 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOREST" b2="230 KV" b3="B30" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOREST" b2="230 KV" b3="FOR-SQU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SQUABHOL" b2="230 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SQUABHOL" b2="230 KV" b3="B7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79020</SeqNum>
    <Name>SquabHollow.SVC</Name>
    <LastEdit Timestamp="2025-02-20T13:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SQUABHOL" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SQUABHOL" b2="230 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79030</SeqNum>
    <Name>230/138.Athenia.220-2</Name>
    <LastEdit Timestamp="2024-08-06T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="2-6" />
      <ContingencyEquipment Action="X" Type="XF" b1="ATHENIA" b2="230 KV" b3="220-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="220-2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79040</SeqNum>
    <Name>L138.Dorton-Beefhide-Jackhorn</Name>
    <LastEdit Timestamp="2026-05-20T17:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEEFHIDE" b2="138 KV" b3="BEE-DOR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEEFHIDE" b2="138 KV" b3="BEE-JACK" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEEFHIDE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DORTON" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKHORN" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79050</SeqNum>
    <Name>L138.ClinchRiver-Lockhart-Dorton</Name>
    <LastEdit Timestamp="2024-08-08T12:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DORTON" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOCKHART" b2="138 KV" b3="CLI-LOC" />
      <ContingencyEquipment Action="L" Type="LN" b1="DORTON" b2="138 KV" b3="DOR-LOC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOCKHART" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79060</SeqNum>
    <Name>L138.Brues-WestBellaire.1</Name>
    <LastEdit Timestamp="2024-08-08T12:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUES" b2="138 KV" b3="BRU-WBE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUES" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="138 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79070</SeqNum>
    <Name>138/69.Brues.TX4</Name>
    <LastEdit Timestamp="2024-08-08T11:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUES" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUES" b2="138 KV" b3="TX4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUES" b2="138 KV" b3="XT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79080</SeqNum>
    <Name>L69.Lincoln-SouthMillville.0603</Name>
    <LastEdit Timestamp="2024-08-08T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN3" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN3" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLN3" b2="69 KV" b3="LIN-SMIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMILLVIL" b2="69 KV" b3="OCB D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79100</SeqNum>
    <Name>L500.NorthAnna-Spotsylvania.573</Name>
    <LastEdit Timestamp="2025-01-24T09:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="500 KV" b3="57302" />
      <ContingencyEquipment Action="L" Type="LN" b1="NANNA4" b2="500 KV" b3="573B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="500 KV" b3="XT573" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="500 KV" b3="515T573" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="500 KV" b3="H1T573" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79110</SeqNum>
    <Name>L115.Oakgreen-Unionville-LocustGrove-Pineglade.153</Name>
    <LastEdit Timestamp="2025-12-04T17:40:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LOCUSTDP" b2="115 KV" b3="LOC-PINE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOCUSTDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGREEN" b2="115 KV" b3="11T153" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGREEN" b2="115 KV" b3="2T153" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="OAKGREEN" b2="115 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGREEN" b2="115 KV" b3="SC102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEGLAD" b2="115 KV" b3="15342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEGLAD" b2="115 KV" b3="153T1046" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOCUSTDP" b2="115 KV" b3="153A" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKGREEN" b2="115 KV" b3="153D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIONVIL" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79120</SeqNum>
    <Name>L115.LakeOfTheWoods-Spotsylvania.37</Name>
    <LastEdit Timestamp="2024-08-12T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="WILDERNS" b2="115 KV" b3="37A" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEOFWD" b2="115 KV" b3="37A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAKEOFWD" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAKEOFWD" b2="115 KV" b3="WILDNSDP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="115 KV" b3="3772" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="115 KV" b3="37T198" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79140</SeqNum>
    <Name>L138.OhioCentral-Powelson</Name>
    <LastEdit Timestamp="2024-08-08T14:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="F2" />
      <ContingencyEquipment Action="L" Type="LN" b1="OHIOCENT" b2="138 KV" b3="OHI-POW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POWELSON" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79170</SeqNum>
    <Name>138/69.Greenlawn.T3</Name>
    <LastEdit Timestamp="2024-08-08T11:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENLAW" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENLAW" b2="138 KV" b3="T3 XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENLAW" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79200</SeqNum>
    <Name>L115.Basin-MauryStreet-Manchester.24</Name>
    <LastEdit Timestamp="2024-08-08T11:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASIN" b2="115 KV" b3="2442" />
      <ContingencyEquipment Action="L" Type="LN" b1="BASIN" b2="115 KV" b3="24A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANCHSTR" b2="115 KV" b3="2432-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANCHSTR" b2="115 KV" b3="2432-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAURYST" b2="115 KV" b3="24B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAURYST" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79270</SeqNum>
    <Name>L115.ChaseCity-RidgeRoad.1009</Name>
    <LastEdit Timestamp="2025-06-19T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHASECTY" b2="115 KV" b3="100912" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHASECTY" b2="115 KV" b3="1009A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGROAD" b2="115 KV" b3="100972" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGROAD" b2="115 KV" b3="ZT1009" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79320</SeqNum>
    <Name>L138.Hebron1-EkpHebron + 138/69.EkpHebron.TXF</Name>
    <LastEdit Timestamp="2024-08-20T10:01:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HEBRN_EK" b2="138 KV" b3="LD_151" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRN_EK" b2="69 KV" b3="N69-608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRN_EK" b2="138 KV" b3="N69-808" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRN_EK" b2="138 KV" b3="N69-908" />
      <ContingencyEquipment Action="X" Type="XF" b1="HEBRN_EK" b2="138 KV" b3="XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRON1" b2="138 KV" b3="853" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRON1" b2="138 KV" b3="855" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEBRON1" b2="138 KV" b3="EKH-HEB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79330</SeqNum>
    <Name>L138.MiamiFort-Hebron.1683</Name>
    <LastEdit Timestamp="2024-08-12T12:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRON1" b2="138 KV" b3="855" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRON1" b2="138 KV" b3="857" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIAMIFOR" b2="138 KV" b3="MIA-HEB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="926" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79340</SeqNum>
    <Name>500/138.FlintRun.T2</Name>
    <LastEdit Timestamp="2025-07-31T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="500 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="500 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLINTRUN" b2="500 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79430</SeqNum>
    <Name>L115.SkiffesCreek-YtNavWpn-Lebanon-Yorktown.58</Name>
    <LastEdit Timestamp="2025-08-19T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LEBANON4" b2="115 KV" b3="58K" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEBANON4" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEBANON4" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="115 KV" b3="19T58" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="115 KV" b3="5872" />
      <ContingencyEquipment Action="L" Type="LN" b1="SKFFSCRK" b2="115 KV" b3="58A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="115 KV" b3="5882" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEBANON4" b2="115 KV" b3="58G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YTNAVWPN" b2="115 KV" b3="H132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="YTNAVWPN" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79450</SeqNum>
    <Name>L69.Tasley-Kellam.6721</Name>
    <LastEdit Timestamp="2024-08-08T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KELLAM" b2="69 KV" b3="70" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELLAM" b2="69 KV" b3="71" />
      <ContingencyEquipment Action="L" Type="LN" b1="KELLAM" b2="69 KV" b3="KEL-TASL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TASLEY" b2="69 KV" b3="7420" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TASLEY" b2="69 KV" b3="7490" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79470</SeqNum>
    <Name>L138.Muskingum-WolfCreek</Name>
    <LastEdit Timestamp="2024-08-08T14:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="138 KV" b3="HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFCREE" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="L" Type="LN" b1="MUSKING2" b2="138 KV" b3="MUS-WOL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79540</SeqNum>
    <Name>L69.Cook-Derby</Name>
    <LastEdit Timestamp="2025-05-27T16:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COOK" b2="69 KV" b3="COO-DER2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DERBY" b2="69 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DERBY" b2="69 KV" b3="N2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79550</SeqNum>
    <Name>L69.Buchanan-Pletcher</Name>
    <LastEdit Timestamp="2024-08-08T15:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCHANAN" b2="69 KV" b3="MM" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCHANAN" b2="69 KV" b3="BUC-PLE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLETCHER" b2="69 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79560</SeqNum>
    <Name>L69.Buchanan-BuchananTap-MayflowerRoad</Name>
    <LastEdit Timestamp="2024-08-09T15:42:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BUCHANAN" b2="69 KV" b3="BUC-BUC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCHANAN" b2="69 KV" b3="LL" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCHANTP" b2="69 KV" b3="BUC-MAY1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUCHANTP" b2="69 KV" b3="SBUCHANA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLWRD" b2="69 KV" b3="BUCH_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79570</SeqNum>
    <Name>L69.Bosserman-NewBuffalo-ThreeOak</Name>
    <LastEdit Timestamp="2025-05-02T13:06:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOSSERMN" b2="69 KV" b3="BOS-NEWB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NEWBUFFA" b2="69 KV" b3="CAPB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWBUFFA" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWBUFFA" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THREEOAK" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWBUFFA" b2="69 KV" b3="NEW-THR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79580</SeqNum>
    <Name>L500.BrunswickSwitchingStationHeritage-Wake.570</Name>
    <LastEdit Timestamp="2025-06-03T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSSWY" b2="500 KV" b3="509T570" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSSWY" b2="500 KV" b3="57062" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNSSWY" b2="500 KV" b3="570A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKE4" b2="500 KV" b3="6HERCUMB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKE4" b2="500 KV" b3="6HER_BK2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79590</SeqNum>
    <Name>L345.HomerCity-Mainesburg</Name>
    <LastEdit Timestamp="2025-08-13T14:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="345 KV" b3="B308" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="345 KV" b3="B309" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOMERCIT" b2="345 KV" b3="HOM-MAI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINESBG" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINESBG" b2="345 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79600</SeqNum>
    <Name>L345.Mainesburg-Watercure [NYISO]</Name>
    <LastEdit Timestamp="2026-02-13T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINESBG" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINESBG" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAINESBG" b2="345 KV" b3="MAI-WAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERCUR" b2="345 KV" b3="30-B142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERCUR" b2="345 KV" b3="3042" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79610</SeqNum>
    <Name>345/115.Mainesburg.T1</Name>
    <LastEdit Timestamp="2024-11-05T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINESBG" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINESBG" b2="115 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINESBG" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINESBG" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINESBG" b2="115 KV" b3="B9" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MAINESBG" b2="345 KV" b3="CAP1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MAINESBG" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79620</SeqNum>
    <Name>L115.Mainesburg-Mansfield</Name>
    <LastEdit Timestamp="2024-08-08T11:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINESBG" b2="115 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINESBG" b2="115 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAINESBG" b2="115 KV" b3="MAI-MAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANS PN" b2="115 KV" b3="ETOWANDA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79630</SeqNum>
    <Name>L115.Everts-Mainesburg</Name>
    <LastEdit Timestamp="2025-03-18T14:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERTSUB" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERTSUB" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="EVERTSUB" b2="115 KV" b3="EVE-MAI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINESBG" b2="115 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINESBG" b2="115 KV" b3="B9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79640</SeqNum>
    <Name>L138.Elko-SquabHollow</Name>
    <LastEdit Timestamp="2024-08-08T12:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELKO" b2="138 KV" b3="BROOKVIL" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKO" b2="138 KV" b3="ELK-SQU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SQUABHOL" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SQUABHOL" b2="138 KV" b3="B17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79680</SeqNum>
    <Name>L138.Edgemont-Claytor</Name>
    <LastEdit Timestamp="2024-08-08T12:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYTOR" b2="138 KV" b3="CLA-EDG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTOR" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMONT" b2="138 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79690</SeqNum>
    <Name>L69.CedarNeck-Bethany.6740</Name>
    <LastEdit Timestamp="2025-05-06T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="69 KV" b3="7530" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="69 KV" b3="7540" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHANY" b2="69 KV" b3="BET-CED" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARNEC" b2="69 KV" b3="65" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARNEC" b2="69 KV" b3="66" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79700</SeqNum>
    <Name>L138.Waterman-H452.11305</Name>
    <LastEdit Timestamp="2025-02-07T12:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="H452" b2="138 KV" b3="H45-WATE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="113 WATE" b2="138 KV" b3="L11305CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H452" b2="138 KV" b3="BT1-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79710</SeqNum>
    <Name>Perryman.CT6</Name>
    <LastEdit Timestamp="2024-08-09T15:39:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMN6" b2="115 KV" b3="130006CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMN6" b2="13.8 KV" b3="6SYNC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PERRYMN6" b2="13.8 KV" b3="LOAD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PERRYMN6" b2="13.8 KV" b3="PERYMAN6" />
      <ContingencyEquipment Action="X" Type="XF" b1="PERRYMN6" b2="115 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79720</SeqNum>
    <Name>Perryman.U51</Name>
    <LastEdit Timestamp="2024-08-09T15:27:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PERRYMAN" b2="115 KV" b3="51-CT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="51SYNCBK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PERRYMAN" b2="33 KV" b3="CT 51" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79730</SeqNum>
    <Name>Perryman.CT1</Name>
    <LastEdit Timestamp="2024-08-09T15:26:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PERRYMAN" b2="115 KV" b3="110-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="110615GC" />
      <ContingencyEquipment Action="S" Type="SD" b1="PERRYMAN" b2="115 KV" b3="110615SD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="615_621" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PERRYMAN" b2="13 KV" b3="CT 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79740</SeqNum>
    <Name>Perryman.U3&amp;4</Name>
    <LastEdit Timestamp="2025-04-21T15:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PERRYMAN" b2="115 KV" b3="110-34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="110616GC" />
      <ContingencyEquipment Action="S" Type="SD" b1="PERRYMAN" b2="115 KV" b3="110616SD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="616_620" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PERRYMAN" b2="13 KV" b3="CT 3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PERRYMAN" b2="13 KV" b3="CT 4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79750</SeqNum>
    <Name>L69.Hensley-Millville</Name>
    <LastEdit Timestamp="2024-11-20T16:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HENSLEY" b2="69 KV" b3="764" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HENSLEY" b2="69 KV" b3="767" />
      <ContingencyEquipment Action="L" Type="LN" b1="HENSLEY" b2="69 KV" b3="HEN-MILV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HENSLEY" b2="69 KV" b3="STA SERV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILVIL" b2="69 KV" b3="LD41" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MILVIL" b2="69 KV" b3="SW386" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MILVIL" b2="69 KV" b3="SW8916" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79770</SeqNum>
    <Name>L69.Hensley-Canal-Kennel</Name>
    <LastEdit Timestamp="2026-05-21T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08CANAL" b2="69 KV" b3="TB1 LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HENSLEY" b2="69 KV" b3="769" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HENSLEY" b2="69 KV" b3="771" />
      <ContingencyEquipment Action="L" Type="LN" b1="08CANAL" b2="69 KV" b3="CAN-HENS" />
      <ContingencyEquipment Action="L" Type="LN" b1="08CANAL" b2="69 KV" b3="CAN-KENN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNEL" b2="69 KV" b3="CB740" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNEL" b2="69 KV" b3="CB748" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79970</SeqNum>
    <Name>230/115.Rocktown.TR3</Name>
    <LastEdit Timestamp="2024-11-14T15:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKTOWN" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKTOWN" b2="35 KV" b3="B28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKTOWN" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKTOWN" b2="35 KV" b3="LOAD1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROCKTOWN" b2="35 KV" b3="MUIRHDSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKTOWN" b2="230 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79980</SeqNum>
    <Name>138/69.Breinigsville.TX3</Name>
    <LastEdit Timestamp="2024-08-08T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRNGSVIL" b2="138 KV" b3="TRAN1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRNGSVIL" b2="69 KV" b3="TRAN3CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRNGSVIL" b2="138 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>79990</SeqNum>
    <Name>138/69.Breinigsville.TX4</Name>
    <LastEdit Timestamp="2024-08-08T11:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRNGSVIL" b2="138 KV" b3="TRAN2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRNGSVIL" b2="69 KV" b3="TRAN4CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRNGSVIL" b2="138 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80020</SeqNum>
    <Name>L138.Mayfield-Pawnee-LeroyCenter.Q2</Name>
    <LastEdit Timestamp="2025-02-10T13:35:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02PAWNEE" b2="138 KV" b3="SWR232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAYFLD" b2="138 KV" b3="04M-PAW2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAWNEETP" b2="138 KV" b3="PAW-02P2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAWNEETP" b2="138 KV" b3="PAW-LER2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80080</SeqNum>
    <Name>L345.KenzigRoad-Speed</Name>
    <LastEdit Timestamp="2024-11-13T13:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIGRD" b2="345 KV" b3="4536-73" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIGRD" b2="345 KV" b3="4573-74" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENZIGRD" b2="345 KV" b3="KEN-SPE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPEED" b2="345 KV" b3="30-39" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPEED" b2="345 KV" b3="39-B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80090</SeqNum>
    <Name>L345.KenzigRoad-Ramsey</Name>
    <LastEdit Timestamp="2024-08-09T15:46:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIGRD" b2="345 KV" b3="4535-74" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIGRD" b2="345 KV" b3="4573-74" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENZIGRD" b2="345 KV" b3="KEN-RAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMSEYHE" b2="345 KV" b3="1822" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMSEYHE" b2="345 KV" b3="1842" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80100</SeqNum>
    <Name>L345.KenzigRoad-PaddysWest</Name>
    <LastEdit Timestamp="2024-08-09T10:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIGRD" b2="345 KV" b3="4535-36" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIGRD" b2="345 KV" b3="4535-74" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENZIGRD" b2="345 KV" b3="KEN-PAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADDYS_W" b2="345 KV" b3="4533_35T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADDYS_W" b2="345 KV" b3="4535_TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80110</SeqNum>
    <Name>L345.KenzigRoad-NorthSide</Name>
    <LastEdit Timestamp="2024-08-09T15:44:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIGRD" b2="345 KV" b3="4535-36" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIGRD" b2="345 KV" b3="4536-73" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENZIGRD" b2="345 KV" b3="KEN-NSD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_SIDE" b2="345 KV" b3="345KVTR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80120</SeqNum>
    <Name>345/138.Northbrook.TR81</Name>
    <LastEdit Timestamp="2024-08-09T09:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="159 NORT" b2="345 KV" b3="TR81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="159 NORT" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="159 NORT" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="159 NORT" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80130</SeqNum>
    <Name>L138.WillCounty-0905-Joliet</Name>
    <LastEdit Timestamp="2025-03-18T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="9 JOLIET" b2="138 KV" b3="0905 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="0905" b2="138 KV" b3="0905 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="0905" b2="138 KV" b3="0905 6" />
      <ContingencyEquipment Action="S" Type="SD" b1="0905" b2="138 KV" b3="0905 7" />
      <ContingencyEquipment Action="L" Type="LN" b1="0905" b2="138 KV" b3="0905 8" />
      <ContingencyEquipment Action="L" Type="LN" b1="18 WILL" b2="138 KV" b3="0905 4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="18 WILL" b2="138 KV" b3="L0905 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="18 WILL" b2="138 KV" b3="L0905TBD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="436 HILL" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="456 JOL" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="9 JOLIET" b2="138 KV" b3="0905B1CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="9 JOLIET" b2="138 KV" b3="TR79" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80140</SeqNum>
    <Name>L138.ProspectHeights-1708-Aptakisik.11708</Name>
    <LastEdit Timestamp="2024-11-05T14:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="109 APTA" b2="138 KV" b3="L11708CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="L11708CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="109 APTA" b2="138 KV" b3="11708 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="11708" b2="138 KV" b3="11708 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="11708" b2="138 KV" b3="11708 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="117 PROS" b2="138 KV" b3="11708 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="11708" b2="138 KV" b3="11708 Z2" />
      <ContingencyEquipment Action="L" Type="LN" b1="217 PROS" b2="138 KV" b3="11708 Z3" />
      <ContingencyEquipment Action="L" Type="LN" b1="11708" b2="138 KV" b3="11708 Z4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="205 WHEE" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="217 PROS" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="237 BUFF" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80150</SeqNum>
    <Name>765/345.Mountaineer.T2 + L345.Mountaineer-Sporn</Name>
    <LastEdit Timestamp="2024-11-05T15:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUNTAIN" b2="765 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUNTAIN" b2="765 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUNTAIN" b2="345 KV" b3="MOU-SPOR" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOUNTAIN" b2="765 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="MM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="MM2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80160</SeqNum>
    <Name>230/138.SquabHollow.TR1</Name>
    <LastEdit Timestamp="2024-08-09T15:45:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SQUABHOL" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SQUABHOL" b2="138 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SQUABHOL" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SQUABHOL" b2="230 KV" b3="B7" />
      <ContingencyEquipment Action="X" Type="XF" b1="SQUABHOL" b2="230 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80180</SeqNum>
    <Name>L138.Trailfork-AloeVeraSwitch-Baileysville</Name>
    <LastEdit Timestamp="2026-03-10T15:54:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALOEVERA" b2="138 KV" b3="ALO-TRAI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALOEVERA" b2="138 KV" b3="SPARTAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALOEVERA" b2="138 KV" b3="ALO-BAIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAILEYSV" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRAILFOR" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80210</SeqNum>
    <Name>230/115.Liberty.TX1</Name>
    <LastEdit Timestamp="2024-08-09T09:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="230 KV" b3="H112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="115 KV" b3="L112" />
      <ContingencyEquipment Action="X" Type="XF" b1="LIBERTY1" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80220</SeqNum>
    <Name>230/115.Liberty.TX2</Name>
    <LastEdit Timestamp="2024-08-09T09:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="230 KV" b3="H212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="115 KV" b3="L212" />
      <ContingencyEquipment Action="X" Type="XF" b1="LIBERTY1" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80230</SeqNum>
    <Name>L230.WintersBranch-CloverHill.2132</Name>
    <LastEdit Timestamp="2026-05-11T11:02:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERHL" b2="230 KV" b3="213252-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERHL" b2="230 KV" b3="213252-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERSB" b2="230 KV" b3="21322239" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERSB" b2="230 KV" b3="213272" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVERHL" b2="230 KV" b3="CLO-WINT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80240</SeqNum>
    <Name>L115.WaughChapel-NAJ-Ridgevw-RockAve-Tipton.110538</Name>
    <LastEdit Timestamp="2025-04-22T13:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CANINERD" b2="115 KV" b3="CAN-MAP8" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NAJ" b2="115 KV" b3="1_4TR38" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="NAJ" b2="115 KV" b3="2_6TR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NAJ" b2="115 KV" b3="3TR538" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="NAJ" b2="115 KV" b3="3TR539" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NAJ" b2="115 KV" b3="6TR538" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIDGVIEW" b2="115 KV" b3="NAJ-RID" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKAVE" b2="115 KV" b3="ROC-NAJ2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RIDGVIEW" b2="115 KV" b3="1-2TIE" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIDGVIEW" b2="115 KV" b3="110-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RIDGVIEW" b2="13.8 KV" b3="110-2 LS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="RIDGVIEW" b2="13.8 KV" b3="TIEBKR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKAVE" b2="115 KV" b3="110538C" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKAVE" b2="115 KV" b3="ROC-TIP8" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="ROCKAVE" b2="115 KV" b3="SW12TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANINERD" b2="115 KV" b3="CAN-TIP8" />
      <ContingencyEquipment Action="L" Type="LN" b1="TIPTON" b2="115 KV" b3="TIP-TIP8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="110538" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="110538SF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="547_538" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAUGHCHA" b2="115 KV" b3="NAJ-WAU8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80250</SeqNum>
    <Name>L115.WaughChapel-NAJ-Ferndal-RockAve-Tipton.110539</Name>
    <LastEdit Timestamp="2025-04-22T13:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CANINERD" b2="115 KV" b3="CAN-MAP9" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FERNDALE" b2="115 KV" b3="110-3 HS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FERNDALE" b2="115 KV" b3="110520-3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FERNDALE" b2="115 KV" b3="110539-2" />
      <ContingencyEquipment Action="CL" Type="CB" b1="FERNDALE" b2="13.8 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="NAJ" b2="115 KV" b3="1_4TR38" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NAJ" b2="115 KV" b3="1_4TR39" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NAJ" b2="115 KV" b3="2TR539" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="NAJ" b2="115 KV" b3="2_6TR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NAJ" b2="115 KV" b3="3TR539" />
      <ContingencyEquipment Action="L" Type="LN" b1="FERNDALE" b2="115 KV" b3="FER-NAJ" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKAVE" b2="115 KV" b3="ROC-NAJ1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKAVE" b2="115 KV" b3="110539C" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKAVE" b2="115 KV" b3="ROC-TIP9" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="ROCKAVE" b2="115 KV" b3="SW12TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANINERD" b2="115 KV" b3="CAN-TIP9" />
      <ContingencyEquipment Action="L" Type="LN" b1="TIPTON" b2="115 KV" b3="TIP-TIP9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="110539" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="110539SF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="539_545" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAUGHCHA" b2="115 KV" b3="NAJ-WAU9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80260</SeqNum>
    <Name>L345.FiveMile-Limelake [NYISO]</Name>
    <LastEdit Timestamp="2026-06-04T14:12:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="5MILE" b2="345 KV" b3="5MI-LIME" />
      <ContingencyEquipment Action="OP" Type="CB" b1="5MILE" b2="345 KV" b3="791" />
      <ContingencyEquipment Action="OP" Type="CB" b1="5MILE" b2="345 KV" b3="794" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMELAKE" b2="345 KV" b3="809" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80320</SeqNum>
    <Name>L230.Lackawanna-Paupack</Name>
    <LastEdit Timestamp="2025-12-10T16:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LACKAWAN" b2="230 KV" b3="LAC-PAU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="PAUPACK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="SMT1PAUP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAUPACK" b2="230 KV" b3="LACK_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAUPACK" b2="230 KV" b3="LACK_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80330</SeqNum>
    <Name>230/69.Springfield.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T12:07:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SPRNGFLD" b2="230 KV" b3="T1 MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRNGFLD" b2="69 KV" b3="TRAN1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPRNGFLD" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80350</SeqNum>
    <Name>L69.Hebron(DEOK)-Hebron(EKPC)</Name>
    <LastEdit Timestamp="2024-08-20T10:03:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRN_EK" b2="69 KV" b3="N69-624" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRON1" b2="69 KV" b3="646" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEBRN_EK" b2="69 KV" b3="HEB-HEBR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80360</SeqNum>
    <Name>L345.Sporn-MuskingumRiver</Name>
    <LastEdit Timestamp="2024-08-09T10:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MUSKING2" b2="345 KV" b3="MUS-SPR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="KK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="345 KV" b3="KK2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80370</SeqNum>
    <Name>Harwood.NEPC</Name>
    <LastEdit Timestamp="2024-08-12T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARWOOD" b2="69 KV" b3="DUM15094" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HARWOOD" b2="69 KV" b3="NEPNUG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80380</SeqNum>
    <Name>Kearny.CT13.A-D</Name>
    <LastEdit Timestamp="2025-07-24T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="11-12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEARNY" b2="13 KV" b3="13CTA" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEARNY" b2="13 KV" b3="13CTB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEARNY" b2="13 KV" b3="13CTC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEARNY" b2="13 KV" b3="13CTD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="2-12" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEARNY" b2="230 KV" b3="TR13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80390</SeqNum>
    <Name>Kearny.CT14.A&amp;B</Name>
    <LastEdit Timestamp="2025-07-24T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="KEARNY" b2="13 KV" b3="14CTA" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEARNY" b2="13 KV" b3="14CTB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEARNY" b2="230 KV" b3="TR_14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80400</SeqNum>
    <Name>Linden.U7&amp;U8</Name>
    <LastEdit Timestamp="2025-01-31T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="138 KV" b3="15-16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="138 KV" b3="2-16" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="138 KV" b3="GSU7-8" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINDEN" b2="13 KV" b3="UNIT07" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINDEN" b2="13 KV" b3="UNIT08" />
      <ContingencyEquipment Action="S" Type="SD" b1="LINDEN" b2="138 KV" b3="UNIT7_8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80410</SeqNum>
    <Name>Mercer.WHNUG</Name>
    <LastEdit Timestamp="2024-08-09T10:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MERCER" b2="230 KV" b3="WH XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCER" b2="230 KV" b3="WHEELBKR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MERCER" b2="13 KV" b3="WHNUG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80420</SeqNum>
    <Name>MeldahlDam.CC + L138.MeldahlDam-MeldahlDamTap</Name>
    <LastEdit Timestamp="2024-08-12T14:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MELDALTP" b2="138 KV" b3="113" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELDALTP" b2="345 KV" b3="1535" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELDALTP" b2="345 KV" b3="1539" />
      <ContingencyEquipment Action="L" Type="LN" b1="MELDALTP" b2="138 KV" b3="MEL-MEL1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MELDALTP" b2="345 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELDDAM" b2="138 KV" b3="52L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80430</SeqNum>
    <Name>L500.Carson-Rawlings.511</Name>
    <LastEdit Timestamp="2025-05-15T09:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARSON4" b2="500 KV" b3="511" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="500 KV" b3="51172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="500 KV" b3="511T544" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAWLINGS" b2="500 KV" b3="51192" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAWLINGS" b2="500 KV" b3="511T556" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80440</SeqNum>
    <Name>L500.Clover-Rawlings.556</Name>
    <LastEdit Timestamp="2025-09-18T16:55:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVER" b2="500 KV" b3="556B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="500 KV" b3="BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="500 KV" b3="BUCK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="500 KV" b3="H7T556" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="500 KV" b3="H8T556" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="500 KV" b3="H9T556" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="500 KV" b3="SV112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAWLINGS" b2="500 KV" b3="511T556" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAWLINGS" b2="500 KV" b3="55692" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80450</SeqNum>
    <Name>L69.Cambridge-Bayly-MacesLane.6764</Name>
    <LastEdit Timestamp="2025-12-15T13:41:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAYLY" b2="69 KV" b3="BAY-CAM" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYLY" b2="69 KV" b3="BAY-MAC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BAYLY" b2="69 KV" b3="BAYLY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIDG" b2="69 KV" b3="7150" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIDG" b2="69 KV" b3="7170" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACELANE" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACELANE" b2="69 KV" b3="63" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80550</SeqNum>
    <Name>L138.Howard-Melmore</Name>
    <LastEdit Timestamp="2024-09-30T14:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOWARD2" b2="138 KV" b3="HOW-MEL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELMORE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELMORE" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80560</SeqNum>
    <Name>L138.Greelawn-Melmore</Name>
    <LastEdit Timestamp="2024-08-09T09:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GREENLAW" b2="138 KV" b3="GRE-MEL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENLAW" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELMORE" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELMORE" b2="138 KV" b3="E1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80630</SeqNum>
    <Name>L138.ShawneeRoad-SouthWestLima</Name>
    <LastEdit Timestamp="2025-07-17T16:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEER" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="138 KV" b3="J2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHAWNEER" b2="138 KV" b3="SHA-SWL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80720</SeqNum>
    <Name>L138.64Bellwood-D460.6405</Name>
    <LastEdit Timestamp="2022-09-08T09:48:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="138 KV" b3="14-15" />
      <ContingencyEquipment Action="L" Type="LN" b1="64 BELLW" b2="138 KV" b3="6405" />
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="138 KV" b3="BT11-14" />
      <ContingencyEquipment Action="CL" Type="CB" b1="D460-6" b2="138 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="D460-6" b2="138 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="D460-6" b2="138 KV" b3="6-7" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="D460-6" b2="138 KV" b3="TR76_34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80730</SeqNum>
    <Name>TMI.LD2 &amp; LD3.StationService</Name>
    <LastEdit Timestamp="2026-02-10T11:33:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="230 KV" b3="105102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="230 KV" b3="109112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="230 KV" b3="B7" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TMI" b2="230 KV" b3="LOAD3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80740</SeqNum>
    <Name>TMI.LD1.StationService</Name>
    <LastEdit Timestamp="2026-02-10T11:33:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="230 KV" b3="109102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="230 KV" b3="109202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="230 KV" b3="B41" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TMI" b2="230 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80780</SeqNum>
    <Name>OysterCreek.BK7.StationService</Name>
    <LastEdit Timestamp="2026-05-08T10:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OYSTERCR" b2="230 KV" b3="B111" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OYSTERCR" b2="230 KV" b3="B77" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OYSTERCR" b2="230 KV" b3="BK 7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80790</SeqNum>
    <Name>OysterCreek.BK8.StationService</Name>
    <LastEdit Timestamp="2024-10-28T15:51:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OYSTERCR" b2="230 KV" b3="B114" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OYSTERCR" b2="230 KV" b3="B80" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OYSTERCR" b2="230 KV" b3="BK 8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>80970</SeqNum>
    <Name>230/13.Limerick.10AUX.StationService</Name>
    <LastEdit Timestamp="2024-08-09T15:43:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LIMERICK" b2="230 KV" b3="10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LIMERICK" b2="13 KV" b3="10AUX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="230 KV" b3="715 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="230 KV" b3="725 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMERICK" b2="230 KV" b3="735 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81300</SeqNum>
    <Name>500/13.HopeCreek.T1&amp;3.StationService</Name>
    <LastEdit Timestamp="2026-02-10T12:00:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="SECT1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="SECT1-5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOPECREE" b2="500 KV" b3="SLP_1_NC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOPECREE" b2="500 KV" b3="SLP_3_NC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81350</SeqNum>
    <Name>500/13.Salem.T1&amp;3.StationService</Name>
    <LastEdit Timestamp="2026-02-10T11:36:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT2-8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SALEM" b2="500 KV" b3="SLP_1_NC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SALEM" b2="500 KV" b3="SLP_3_NC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81360</SeqNum>
    <Name>500/13.Salem.T2&amp;4.StationService</Name>
    <LastEdit Timestamp="2026-02-10T11:37:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT1-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALEM" b2="500 KV" b3="SECT1-9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SALEM" b2="500 KV" b3="SLP_2_NC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SALEM" b2="500 KV" b3="SLP_4_NC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81720</SeqNum>
    <Name>230/115.NorthMeshoppen.T3</Name>
    <LastEdit Timestamp="2025-02-24T09:05:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NMESHOPP" b2="230 KV" b3="#3 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="115 KV" b3="B103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="115 KV" b3="B104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="230 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="230 KV" b3="B28" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81730</SeqNum>
    <Name>138/69.Hartford.T1</Name>
    <LastEdit Timestamp="2025-08-11T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HARTFORD" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARTFORD" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARTFORD" b2="34.5 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARTFORD" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARTFORD" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81760</SeqNum>
    <Name>L138.LeroyCenter-Stacy.Q3</Name>
    <LastEdit Timestamp="2024-08-09T09:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B82" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEROYCEN" b2="138 KV" b3="LER-STAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STACY" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STACY" b2="138 KV" b3="B9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81770</SeqNum>
    <Name>L138.EastLake-Newell-Nash-GrandRiver.Q16</Name>
    <LastEdit Timestamp="2025-07-24T16:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02NASH" b2="138 KV" b3="02N-NEW2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="02NASH" b2="138 KV" b3="SW323" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02NASH" b2="138 KV" b3="SWR230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B36" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTLAKE" b2="138 KV" b3="EAS-NEW2" />
      <ContingencyEquipment Action="L" Type="LN" b1="02NASH" b2="138 KV" b3="02N-GRR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDRVR" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDRVR" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="NEWELL" b2="138 KV" b3="SW656" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWELL" b2="138 KV" b3="SWR632" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81790</SeqNum>
    <Name>L345.Beaver-LakeAvenue.1</Name>
    <LastEdit Timestamp="2024-08-09T10:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="121" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="161" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVER" b2="345 KV" b3="BEA-LAK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="345 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="345 KV" b3="B7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81800</SeqNum>
    <Name>L345.Beaver-LakeAvenue.2</Name>
    <LastEdit Timestamp="2024-08-09T10:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="216" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="345 KV" b3="219" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVER" b2="345 KV" b3="BEA-LAK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="345 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81810</SeqNum>
    <Name>L345.AvonLake-LakeAvenue.1</Name>
    <LastEdit Timestamp="2024-12-30T14:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AVONLAK2" b2="345 KV" b3="AVO-LAK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="345 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="345 KV" b3="B350" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="345 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="345 KV" b3="B8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81830</SeqNum>
    <Name>L345.AvonLake-LakeAvenue.2</Name>
    <LastEdit Timestamp="2025-02-07T12:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AVONLAK2" b2="345 KV" b3="AVO-LAK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="345 KV" b3="B351" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="345 KV" b3="B352" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="345 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81840</SeqNum>
    <Name>345/138.LakeAvenue.T1</Name>
    <LastEdit Timestamp="2024-08-09T09:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="138 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="345 KV" b3="B6" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKEAVE2" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81850</SeqNum>
    <Name>345/138.LakeAvenue.T2</Name>
    <LastEdit Timestamp="2024-08-09T09:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="138 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="345 KV" b3="B8" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKEAVE2" b2="345 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81860</SeqNum>
    <Name>L138.Johnson-LakeAvenue.1</Name>
    <LastEdit Timestamp="2024-10-30T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSOFE" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="JOHNSOFE" b2="138 KV" b3="A37" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSOFE" b2="138 KV" b3="JOH-LAK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="138 KV" b3="B15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81870</SeqNum>
    <Name>L138.Johnson-LakeAvenue.2</Name>
    <LastEdit Timestamp="2024-08-12T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSOFE" b2="138 KV" b3="170" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="JOHNSOFE" b2="138 KV" b3="A173" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="138 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="138 KV" b3="B18" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSOFE" b2="138 KV" b3="JOH-LAK2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81880</SeqNum>
    <Name>L138.BlackRiver-LakeAvenue.1</Name>
    <LastEdit Timestamp="2024-08-12T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKRIV" b2="138 KV" b3="BLA-LAK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="138 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="138 KV" b3="B14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81890</SeqNum>
    <Name>L138.BlackRiver-LakeAvenue.2</Name>
    <LastEdit Timestamp="2024-08-12T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKRIV" b2="138 KV" b3="BLA-LAK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVE2" b2="138 KV" b3="B17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81900</SeqNum>
    <Name>L138.Belmont-WillowIslandHydro</Name>
    <LastEdit Timestamp="2025-03-27T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B24" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="138 KV" b3="BEL-WILH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLOWIH" b2="138 KV" b3="52 L1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WILLOWIH" b2="138 KV" b3="GSU1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WILLOWIH" b2="138 KV" b3="GSU2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WILLOWIH" b2="6.9 KV" b3="WILLHYD1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WILLOWIH" b2="6.9 KV" b3="WILLHYD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81960</SeqNum>
    <Name>L138.Buckhannon-RiderSS</Name>
    <LastEdit Timestamp="2025-04-24T14:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKHANN" b2="138 KV" b3="B50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDERSS" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDERSS" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKHANN" b2="138 KV" b3="BUC-RID" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81980</SeqNum>
    <Name>L138.OakMound-RiderSS</Name>
    <LastEdit Timestamp="2024-08-12T12:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="OAKMOUND" b2="138 KV" b3="OAK-RID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKMOUND" b2="138 KV" b3="RIDER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDERSS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDERSS" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>81990</SeqNum>
    <Name>L138.RiderSS-WestMilford</Name>
    <LastEdit Timestamp="2024-10-03T15:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDERSS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDERSS" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIDERSS" b2="138 KV" b3="RID-WMI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WMIL APS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82000</SeqNum>
    <Name>L138.RiderSS-VensRunTap-Weston</Name>
    <LastEdit Timestamp="2025-05-12T14:31:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDERSS" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDERSS" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIDERSS" b2="138 KV" b3="RID-VENS" />
      <ContingencyEquipment Action="L" Type="LN" b1="VENSRUNT" b2="138 KV" b3="VEN-WEST" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VENSRUNT" b2="138 KV" b3="VENSLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTON" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTON" b2="138 KV" b3="CS185J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTON" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82090</SeqNum>
    <Name>L138.DansMountain-Ridgeley</Name>
    <LastEdit Timestamp="2025-02-18T15:40:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DANSMNTN" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANSMNTN" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="DANSMNTN" b2="138 KV" b3="DAN-RID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGELEY" b2="138 KV" b3="B8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82110</SeqNum>
    <Name>L500.Bismark-Doubs</Name>
    <LastEdit Timestamp="2025-10-09T10:41:37" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BISMARK" b2="500 KV" b3="551T583" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBS" b2="500 KV" b3="583" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISMARK" b2="500 KV" b3="58342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="CB 50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="CB 53" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82120</SeqNum>
    <Name>L500.Bismark-MtStorm</Name>
    <LastEdit Timestamp="2026-04-24T08:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MTSTORM4" b2="500 KV" b3="551" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISMARK" b2="500 KV" b3="55142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISMARK" b2="500 KV" b3="551T583" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="551TB3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTSTORM4" b2="500 KV" b3="551TB4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82140</SeqNum>
    <Name>HandsomeLake.U1-U5</Name>
    <LastEdit Timestamp="2024-08-12T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANDSOME" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANDSOME" b2="345 KV" b3="BWHL" />
      <ContingencyEquipment Action="X" Type="XF" b1="HANDSOME" b2="345 KV" b3="CT TRAN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HANDSOME" b2="13 KV" b3="CT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HANDSOME" b2="13 KV" b3="CT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HANDSOME" b2="13 KV" b3="CT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HANDSOME" b2="13 KV" b3="CT4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HANDSOME" b2="13 KV" b3="CT5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HANDSOME" b2="13 KV" b3="SSLOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82150</SeqNum>
    <Name>Krayn WindFarm.U1</Name>
    <LastEdit Timestamp="2024-08-12T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KRAYN" b2="115 KV" b3="3123_B1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KRAYN" b2="34.5 KV" b3="HIGHLDWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="KRAYN" b2="115 KV" b3="TXWF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82160</SeqNum>
    <Name>Krayn WindFarm.U2</Name>
    <LastEdit Timestamp="2024-08-12T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KRAYN" b2="115 KV" b3="3155_B1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KRAYN" b2="34.5 KV" b3="HIGHNOWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="KRAYN" b2="115 KV" b3="TXWF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82170</SeqNum>
    <Name>L230.AsylumTwp-EastTowanda</Name>
    <LastEdit Timestamp="2024-08-12T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASYLUM" b2="230 KV" b3="10ADA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASYLUM" b2="230 KV" b3="20ADA" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASYLUM" b2="230 KV" b3="ASY-ETOW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="230 KV" b3="B38" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="230 KV" b3="B43" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82180</SeqNum>
    <Name>AsylumTwp.U1</Name>
    <LastEdit Timestamp="2024-08-12T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASYLUM" b2="230 KV" b3="10ADA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASYLUM" b2="23 KV" b3="10BACO1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ASYLUM" b2="23 KV" b3="LIBRTY10" />
      <ContingencyEquipment Action="X" Type="XF" b1="ASYLUM" b2="230 KV" b3="T10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82190</SeqNum>
    <Name>AsylumTwp.U2</Name>
    <LastEdit Timestamp="2024-08-12T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASYLUM" b2="230 KV" b3="20ADA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASYLUM" b2="23 KV" b3="20BACO1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ASYLUM" b2="23 KV" b3="LIBRTY20" />
      <ContingencyEquipment Action="X" Type="XF" b1="ASYLUM" b2="230 KV" b3="T20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82200</SeqNum>
    <Name>L138.OakMound-WaldoRun.2</Name>
    <LastEdit Timestamp="2025-03-28T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKMOUND" b2="138 KV" b3="WALDO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="9" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKMOUND" b2="138 KV" b3="OAK-WAL2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82210</SeqNum>
    <Name>L138.OakMound-WaldoRun.1</Name>
    <LastEdit Timestamp="2025-03-28T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="OAKMOUND" b2="138 KV" b3="OAK-WAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKMOUND" b2="138 KV" b3="WALDO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82300</SeqNum>
    <Name>115/SS.Spotsylvania.SST1</Name>
    <LastEdit Timestamp="2026-03-30T18:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="115 KV" b3="3772" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="115 KV" b3="L172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="115 KV" b3="WT1046" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82350</SeqNum>
    <Name>L138.Mayfield-PineyGroveTap-LeroyCenter+Sanborn.T3</Name>
    <LastEdit Timestamp="2024-08-12T12:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEROYCEN" b2="138 KV" b3="LER2-PIN" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAYFLD" b2="138 KV" b3="04M-PIN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEGROV" b2="138 KV" b3="CS332" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINEGROV" b2="138 KV" b3="PIN-PIN3" />
      <ContingencyEquipment Action="X" Type="XF" b1="SANBORN" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANBORN" b2="138 KV" b3="Q3_T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANBORN" b2="34 KV" b3="R3_T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82380</SeqNum>
    <Name>230/34.Limekiln.T5</Name>
    <LastEdit Timestamp="2024-12-19T17:10:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="AQUEDUCT" b2="35 KV" b3="DUMLOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="35 KV" b3="ALPHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="230 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LIMEKILN" b2="35 KV" b3="DUMFAI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="35 KV" b3="JEFFERSO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="230 KV" b3="MONOCACY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="35 KV" b3="SFREDRIK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="35 KV" b3="T5LSCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LIMEKILN" b2="230 KV" b3="TR5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MONTGOME" b2="35 KV" b3="DUMLOAD1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MONTGOME" b2="35 KV" b3="DUMLOAD3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82420</SeqNum>
    <Name>138/34.Monocacy.T3</Name>
    <LastEdit Timestamp="2024-11-21T14:25:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="MONOCACY" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONOCACY" b2="34.5 KV" b3="T3LCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONOCACY" b2="138 KV" b3="T4 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MONOCACY" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONOCACY" b2="138 KV" b3="WALKERSV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82430</SeqNum>
    <Name>230/35.Montgomery.T1</Name>
    <LastEdit Timestamp="2026-02-10T12:57:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTGOME" b2="230 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTGOME" b2="230 KV" b3="B29" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MONTGOME" b2="230 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTGOME" b2="230 KV" b3="DAMASCUS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONTGOME" b2="230 KV" b3="T4" />
      <ContingencyEquipment Action="X" Type="XF" b1="MONTGOME" b2="230 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82440</SeqNum>
    <Name>230/35.Montgomery.T3</Name>
    <LastEdit Timestamp="2025-11-17T10:46:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTGOME" b2="230 KV" b3="B29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTGOME" b2="35 KV" b3="DUMTR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTGOME" b2="230 KV" b3="RD207JCT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONTGOME" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="MONTGOME" b2="230 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82460</SeqNum>
    <Name>SouthBend.CT1-CT4</Name>
    <LastEdit Timestamp="2025-08-25T10:30:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SBEND" b2="500 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBEND" b2="500 KV" b3="B3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SBEND" b2="18 KV" b3="CT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SBEND" b2="18 KV" b3="CT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SBEND" b2="18 KV" b3="CT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SBEND" b2="18 KV" b3="CT4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBEND" b2="500 KV" b3="G1HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBEND" b2="500 KV" b3="G2HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBEND" b2="500 KV" b3="G3HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBEND" b2="500 KV" b3="G4HCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SBEND" b2="500 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SBEND" b2="500 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SBEND" b2="500 KV" b3="T3" />
      <ContingencyEquipment Action="X" Type="XF" b1="SBEND" b2="500 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82500</SeqNum>
    <Name>L138.JacksonsFerry-Wythe</Name>
    <LastEdit Timestamp="2024-08-12T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSONS" b2="138 KV" b3="JAC-WYT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="R2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYTHE" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82510</SeqNum>
    <Name>L138.JacksonsFerry-Progress</Name>
    <LastEdit Timestamp="2024-08-12T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSONS" b2="138 KV" b3="JAC-PRO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="S2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PROGRESS" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82520</SeqNum>
    <Name>230/115.WaughChapel.T1</Name>
    <LastEdit Timestamp="2025-06-06T12:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="1-115CP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="110538SF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="110543SF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="14TIE" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAUGHCHA" b2="230 KV" b3="230-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="230-1OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="230-1_42" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WAUGHCHA" b2="115 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="540-1B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82530</SeqNum>
    <Name>L138.SandHill-Wayman</Name>
    <LastEdit Timestamp="2024-08-12T12:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="SANDHIL2" b2="138 KV" b3="SAN-WAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYMAN" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82540</SeqNum>
    <Name>L138.Wayman-Aston</Name>
    <LastEdit Timestamp="2024-08-12T12:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ASTON" b2="138 KV" b3="AST-WAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTON" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTON" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYMAN" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82550</SeqNum>
    <Name>L69.Middle-Peermont.0718</Name>
    <LastEdit Timestamp="2024-08-15T10:55:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MIDD AE" b2="69 KV" b3="MID-PEER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD AE" b2="69 KV" b3="OCB C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEERMONT" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEERMONT" b2="69 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82560</SeqNum>
    <Name>L69.Peermont-Swainton.0797</Name>
    <LastEdit Timestamp="2024-08-15T09:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEERMONT" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEERMONT" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="PEERMONT" b2="69 KV" b3="PEE-SWAI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWAINTON" b2="69 KV" b3="OCB D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82570</SeqNum>
    <Name>L138.Lewis-Mill.1424</Name>
    <LastEdit Timestamp="2024-08-15T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LEWIS" b2="138 KV" b3="LEW-MIL4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="138 KV" b3="OCB P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL" b2="138 KV" b3="AW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82580</SeqNum>
    <Name>L138.Lewis-Mill.1423</Name>
    <LastEdit Timestamp="2024-08-15T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LEWIS" b2="138 KV" b3="LEW-MIL3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="138 KV" b3="OCB T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL" b2="138 KV" b3="Q" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82600</SeqNum>
    <Name>L138.Mill-Scull-England.1408</Name>
    <LastEdit Timestamp="2025-05-28T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-H" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENGLAND" b2="138 KV" b3="ENG-SCU8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILL" b2="138 KV" b3="MIL-SC_8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCULL" b2="138 KV" b3="BUS2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82610</SeqNum>
    <Name>138/69.Mill.T1</Name>
    <LastEdit Timestamp="2024-12-24T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL" b2="138 KV" b3="AW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL" b2="69 KV" b3="BV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILL" b2="138 KV" b3="MILL #1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82620</SeqNum>
    <Name>L230.WaughChapel-RussettEast.2328</Name>
    <LastEdit Timestamp="2025-10-06T11:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSETTE" b2="230 KV" b3="23282330" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSETTE" b2="230 KV" b3="2328TL23" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUSSETTE" b2="230 KV" b3="RUS-WAU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="230-2_28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="2328OCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82630</SeqNum>
    <Name>L230.RussettEast-HighRidge.2338</Name>
    <LastEdit Timestamp="2024-08-15T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="23182338" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="2338CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHRIDG" b2="230 KV" b3="HIG-RUS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSETTE" b2="230 KV" b3="23302338" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSETTE" b2="230 KV" b3="L23T2338" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82640</SeqNum>
    <Name>L230.RussettEast-Tipton.2330</Name>
    <LastEdit Timestamp="2024-10-23T13:14:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSETTE" b2="230 KV" b3="23282330" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSETTE" b2="230 KV" b3="23302338" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUSSETTE" b2="230 KV" b3="RUS-TIP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="230 KV" b3="230-2 HS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82650</SeqNum>
    <Name>L230.WaughChapel-RussettEast.2327</Name>
    <LastEdit Timestamp="2025-10-06T11:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSETTE" b2="230 KV" b3="23272329" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSETTE" b2="230 KV" b3="23272331" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUSSETTE" b2="230 KV" b3="RUS-WAU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="2327OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="230 KV" b3="2327_40" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82660</SeqNum>
    <Name>L230.RussettEast-HighRidge.2316</Name>
    <LastEdit Timestamp="2024-08-15T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="23012316" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="2316CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHRIDG" b2="230 KV" b3="HIG-RUS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSETTE" b2="230 KV" b3="23292316" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSETTE" b2="230 KV" b3="23312316" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82670</SeqNum>
    <Name>L230.RussettEast-Tipton.2329</Name>
    <LastEdit Timestamp="2024-10-18T14:02:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSETTE" b2="230 KV" b3="23272329" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSETTE" b2="230 KV" b3="23292316" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUSSETTE" b2="230 KV" b3="RUS-TIP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="230 KV" b3="230-1 HS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82680</SeqNum>
    <Name>L230.RussettEast-Tipton.2331</Name>
    <LastEdit Timestamp="2024-10-23T13:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSETTE" b2="230 KV" b3="23272331" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSETTE" b2="230 KV" b3="23312316" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUSSETTE" b2="230 KV" b3="RUS-TIP3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="230 KV" b3="230-3 HS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82690</SeqNum>
    <Name>138/69.Tobasco.T5</Name>
    <LastEdit Timestamp="2024-08-15T10:41:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08TBSCO1" b2="138 KV" b3="853" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08TBSCO1" b2="138 KV" b3="866" />
      <ContingencyEquipment Action="X" Type="XF" b1="08TBSCO1" b2="138 KV" b3="BK5_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="08TBSCO1" b2="69 KV" b3="BK5_S" />
      <ContingencyEquipment Action="X" Type="XF" b1="08TBSCO1" b2="13.2 KV" b3="BK5_T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08TBSCO1" b2="13.2 KV" b3="LD5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08TBSCO1" b2="69 KV" b3="SW652" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82700</SeqNum>
    <Name>L138.Highland-Hillsboro</Name>
    <LastEdit Timestamp="2024-08-15T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLND2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLND2" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSBOR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSBOR" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLND2" b2="138 KV" b3="HIG-HIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82710</SeqNum>
    <Name>L138.Highland-NewMarket-Seaman</Name>
    <LastEdit Timestamp="2024-11-08T12:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLND2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLND2" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLND2" b2="138 KV" b3="HIG-NEWM" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWMARK2" b2="138 KV" b3="NEW-SEA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWMARK2" b2="138 KV" b3="NEWMARK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEAMAN" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEAMAN" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82720</SeqNum>
    <Name>138/69.Highland.T3 (AEP)</Name>
    <LastEdit Timestamp="2025-08-19T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLND2" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLND2" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLND2" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIGHLND2" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82730</SeqNum>
    <Name>138/69.WestBellaire.T2</Name>
    <LastEdit Timestamp="2024-11-21T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="138 KV" b3="BT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="138 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="X" Type="XF" b1="WBELLAI2" b2="138 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82740</SeqNum>
    <Name>230/69.Middletown.T9</Name>
    <LastEdit Timestamp="2025-02-26T16:08:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD PE" b2="69 KV" b3="025 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MIDD PE" b2="230 KV" b3="95 CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDD PE" b2="230 KV" b3="MID 9TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82750</SeqNum>
    <Name>L230.Chesapeake-Greenwich.262</Name>
    <LastEdit Timestamp="2025-08-26T17:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="230 KV" b3="26222-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="230 KV" b3="26222-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="230 KV" b3="26252" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENWCH" b2="230 KV" b3="262A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="230 KV" b3="H2T262" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82760</SeqNum>
    <Name>L230.Chesapeake-Yadkin.2158</Name>
    <LastEdit Timestamp="2024-08-15T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="230 KV" b3="215822-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="230 KV" b3="215822-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="215812" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESAPKE" b2="230 KV" b3="2158A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="267T2158" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82770</SeqNum>
    <Name>230/115.Chesapeake.TX2</Name>
    <LastEdit Timestamp="2024-08-15T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="230 KV" b3="H222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESAPKE" b2="115 KV" b3="L222" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESAPKE" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="P" Type="XF" b1="CHESAPKE" b2="230 KV" b3="TX2PAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82780</SeqNum>
    <Name>WestWharton.SVC</Name>
    <LastEdit Timestamp="2025-02-20T13:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="230 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="230 KV" b3="EH OC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WWHARTON" b2="230 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82790</SeqNum>
    <Name>Sayreville.CT1-4</Name>
    <LastEdit Timestamp="2024-08-15T11:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SAYREVIL" b2="230 KV" b3="15 T-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SAYREVIL" b2="13 KV" b3="15 T-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SAYREVIL" b2="13 KV" b3="15 T-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAYREVIL" b2="230 KV" b3="BK 15 GC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SAYREVIL" b2="13 KV" b3="CT 1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SAYREVIL" b2="13 KV" b3="CT 2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SAYREVIL" b2="13 KV" b3="CT 3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SAYREVIL" b2="13 KV" b3="CT 4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82800</SeqNum>
    <Name>L230.Chester-GlenGardner.G2033</Name>
    <LastEdit Timestamp="2026-03-27T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTJCT" b2="230 KV" b3="B106" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTJCT" b2="230 KV" b3="BK 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTJCT" b2="35 KV" b3="BK 1 GCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTJCT" b2="230 KV" b3="CHE-GLE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENGARD" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENGARD" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENGARD" b2="34 KV" b3="B47" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLENGARD" b2="230 KV" b3="BK 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLENGARD" b2="34 KV" b3="R720" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82810</SeqNum>
    <Name>230/34.GlenGardner.T8</Name>
    <LastEdit Timestamp="2024-08-15T10:46:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENGARD" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENGARD" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENGARD" b2="34 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENGARD" b2="230 KV" b3="B53" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLENGARD" b2="230 KV" b3="BK 8" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GLENGARD" b2="230 KV" b3="CAP 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLENGARD" b2="34 KV" b3="T748" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82820</SeqNum>
    <Name>230/34.GlenGardner.T1</Name>
    <LastEdit Timestamp="2024-08-15T10:44:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENGARD" b2="230 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENGARD" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENGARD" b2="34 KV" b3="B46" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLENGARD" b2="230 KV" b3="BK 1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLENGARD" b2="34 KV" b3="G735" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82830</SeqNum>
    <Name>230/35.Manitou.T2</Name>
    <LastEdit Timestamp="2024-08-15T10:52:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="230 KV" b3="B27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="230 KV" b3="B55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="230 KV" b3="B8" />
      <ContingencyEquipment Action="X" Type="XF" b1="MANITOU" b2="230 KV" b3="BK 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MANITOU" b2="230 KV" b3="BK 5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANITOU" b2="35 KV" b3="BK2LOBKR" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MANITOU" b2="230 KV" b3="CAP 5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82850</SeqNum>
    <Name>Warren.CT3</Name>
    <LastEdit Timestamp="2024-08-15T09:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WARREN" b2="115 KV" b3="3 TX 11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="13 KV" b3="CT#3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="115 KV" b3="NO3TX115" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WARREN" b2="13 KV" b3="UNITCT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82860</SeqNum>
    <Name>NewBaltimore.WF1</Name>
    <LastEdit Timestamp="2026-01-09T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="NEW_BALT" b2="34.5 KV" b3="NBALTMWF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEW_BALT" b2="115 KV" b3="XF CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEW_BALT" b2="115 KV" b3="XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82870</SeqNum>
    <Name>L69.EggHarbor-Dacosta.0779</Name>
    <LastEdit Timestamp="2024-08-15T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DACOSTA" b2="69 KV" b3="DAC-EGG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DACOSTA" b2="69 KV" b3="OCB L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EGGHARBO" b2="69 KV" b3="B CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EGGHARBO" b2="69 KV" b3="C CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82880</SeqNum>
    <Name>L138.Bosserman-Bosserni-NewCarlisle.Line1</Name>
    <LastEdit Timestamp="2025-02-20T13:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOSSERMN" b2="138 KV" b3="BOS-BNI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOSSERNI" b2="138 KV" b3="BOS-NNI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCARLI" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWCARLI" b2="138 KV" b3="NEW-NWN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82900</SeqNum>
    <Name>L138.Bosserman-Shoreline</Name>
    <LastEdit Timestamp="2025-10-29T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOSSERMN" b2="138 KV" b3="BOS-SHOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHORELIN" b2="138 KV" b3="13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHORELIN" b2="138 KV" b3="13-119" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82910</SeqNum>
    <Name>L115.NorthEast-Shockoe.20</Name>
    <LastEdit Timestamp="2024-08-15T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SHOCKOE" b2="115 KV" b3="20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="115 KV" b3="2062-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="115 KV" b3="L7T20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHOCKOE" b2="115 KV" b3="20T159" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHOCKOE" b2="115 KV" b3="H222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHOCKOE" b2="115 KV" b3="H322" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHOCKOE" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHOCKOE" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHOCKOE" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHOCKOE" b2="35 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82920</SeqNum>
    <Name>L230.Glebe-PotomacY-NAlexandria + 230/35.Glebe.T1</Name>
    <LastEdit Timestamp="2025-04-29T17:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLEBE" b2="230 KV" b3="250T2023" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLEBE" b2="230 KV" b3="275T2023" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLEBE" b2="230 KV" b3="GLE-POT2" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLEBE" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLEBE" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHALEX" b2="230 KV" b3="202362-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHALEX" b2="230 KV" b3="202362-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NRTHALEX" b2="230 KV" b3="NRT-POTO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82930</SeqNum>
    <Name>L230.JeffersonStreet-CarlyleS-NorthAlexandria.2112</Name>
    <LastEdit Timestamp="2025-04-29T17:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARLYLES" b2="230 KV" b3="CAR-JEFF" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARLYLES" b2="230 KV" b3="CAR-NRTH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFRSON" b2="230 KV" b3="211222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHALEX" b2="230 KV" b3="211262-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHALEX" b2="230 KV" b3="211262-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>82940</SeqNum>
    <Name>L115.Northeast-Chesterfield.17</Name>
    <LastEdit Timestamp="2024-08-15T10:54:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="115 KV" b3="1712" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTER4" b2="115 KV" b3="17A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="115 KV" b3="1762-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="115 KV" b3="L7T17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>83500</SeqNum>
    <Name>345/4.DavisBesse.TR01.StationService</Name>
    <LastEdit Timestamp="2026-01-20T17:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B34560" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B34563" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B66" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAVISBES" b2="345 KV" b3="TR01" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>83510</SeqNum>
    <Name>345/4.DavisBesse.TR02.StationService</Name>
    <LastEdit Timestamp="2026-01-20T17:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B34562" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B65" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISBES" b2="345 KV" b3="B67" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAVISBES" b2="345 KV" b3="TR02" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>83630</SeqNum>
    <Name>DTX230.Post.T1</Name>
    <LastEdit Timestamp="2024-12-02T14:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POST" b2="13 KV" b3="15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POST" b2="230 KV" b3="455" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POST" b2="230 KV" b3="475" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>83780</SeqNum>
    <Name>345/4.Perry.LD100.StationService</Name>
    <LastEdit Timestamp="2025-08-25T13:55:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PERRY_FE" b2="345 KV" b3="LD100" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>83790</SeqNum>
    <Name>DTX345/4.Perry.LD200.StationService</Name>
    <LastEdit Timestamp="2025-08-25T13:56:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PERRY_FE" b2="345 KV" b3="LD200" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84020</SeqNum>
    <Name>L69.Lagrange-N.LagrangeTap-Howe + Reclose (NIPSCO)</Name>
    <LastEdit Timestamp="2024-11-27T10:11:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HOWE" b2="69 KV" b3="166 DIS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HOWE" b2="69 KV" b3="168 DIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOWE" b2="69 KV" b3="HOW-NLA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAGRANGE" b2="69 KV" b3="87" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAGRANGE" b2="69 KV" b3="LAG-NLA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="N_LAGR_T" b2="69 KV" b3="NLAG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84030</SeqNum>
    <Name>138/69.TiffinCenter.T1</Name>
    <LastEdit Timestamp="2025-04-24T14:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFINCE" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFINCE" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLMESSW" b2="69 KV" b3="HOL-TIFF" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIVERVW" b2="69 KV" b3="RIV-TIF" />
      <ContingencyEquipment Action="X" Type="XF" b1="TIFFINCE" b2="138 KV" b3="T1 XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFINCE" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84040</SeqNum>
    <Name>L138.H440-H440N (RMU)</Name>
    <LastEdit Timestamp="2025-11-17T15:10:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="H440" b2="138 KV" b3="2-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H440" b2="138 KV" b3="6-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="H440" b2="138 KV" b3="H440" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H440N" b2="138 KV" b3="L4 110CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84070</SeqNum>
    <Name>L230.Essex-Newark Energy Center.Q-2322</Name>
    <LastEdit Timestamp="2024-08-15T11:07:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="1-15CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="15-16CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ESSEX" b2="230 KV" b3="ESS-NEC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARKEC" b2="230 KV" b3="52-L01" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWARKEC" b2="18 KV" b3="CT1_LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWARKEC" b2="18 KV" b3="CT2_LD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWARKEC" b2="18 KV" b3="CTG11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWARKEC" b2="18 KV" b3="CTG12" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWARKEC" b2="230 KV" b3="GSU10" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWARKEC" b2="230 KV" b3="GSU11" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWARKEC" b2="230 KV" b3="GSU12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWARKEC" b2="18 KV" b3="STG10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84140</SeqNum>
    <Name>L230.Kittatinny-Bushkill.K1019</Name>
    <LastEdit Timestamp="2024-08-15T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUSHKILL" b2="230 KV" b3="KITTCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTATIN" b2="230 KV" b3="B32" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUSHKILL" b2="230 KV" b3="BUS-KIT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84150</SeqNum>
    <Name>L138.CherryCreek-Pemberton</Name>
    <LastEdit Timestamp="2026-05-06T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHERRYCR" b2="138 KV" b3="CHE-PEM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHERRYCR" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEMBERT2" b2="138 KV" b3="R" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84180</SeqNum>
    <Name>L115.Dooms-Midway-Redhill-WalnutCreek.39</Name>
    <LastEdit Timestamp="2026-06-01T16:27:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="115 KV" b3="3942" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOOMS4" b2="115 KV" b3="39A" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDWAYDP" b2="115 KV" b3="39B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDWAYDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDHILL" b2="115 KV" b3="RED-WALN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REDHILL" b2="115 KV" b3="REDH_AEP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALNTCRK" b2="115 KV" b3="39T1067" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALNTCRK" b2="115 KV" b3="39T1068" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84220</SeqNum>
    <Name>138/69.STiffin.T2</Name>
    <LastEdit Timestamp="2025-11-03T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STIFFIN" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STIFFIN" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="X" Type="XF" b1="STIFFIN" b2="138 KV" b3="T2 XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84230</SeqNum>
    <Name>138/69.Howard.T1</Name>
    <LastEdit Timestamp="2024-08-15T10:39:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HOWARD2" b2="138 KV" b3="CAPC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="CC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOWARD2" b2="138 KV" b3="T1 XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="69 KV" b3="U" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84270</SeqNum>
    <Name>500/230.Juniata.T1</Name>
    <LastEdit Timestamp="2025-04-09T13:24:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="JUNIATA" b2="500 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="500 KV" b3="TRAN1FBA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="230 KV" b3="TRAN1_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="230 KV" b3="TRAN1_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84290</SeqNum>
    <Name>L138.Monmouth-CastroIP(ILL.EQ)</Name>
    <LastEdit Timestamp="2024-08-15T11:16:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CASTROIP" b2="138 KV" b3="CAS-MONM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CASTROIP" b2="138 KV" b3="H10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CASTROIP" b2="138 KV" b3="H4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONMOUTH" b2="138 KV" b3="1362" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONMOUTH" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84300</SeqNum>
    <Name>L138.Canton-CastroIP(ILL.EQ)</Name>
    <LastEdit Timestamp="2024-08-15T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CANTON 3" b2="138 KV" b3="1614" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANTON 3" b2="138 KV" b3="CAN-CAST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CASTROIP" b2="138 KV" b3="H4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CASTROIP" b2="138 KV" b3="H8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84320</SeqNum>
    <Name>L138.Nagel-ReedyCreek</Name>
    <LastEdit Timestamp="2025-10-15T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="138 KV" b3="L1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NAGELAEP" b2="138 KV" b3="NAG-REE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEDYCRE" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84350</SeqNum>
    <Name>L500.BrunswickHeritage-Rawlings.591</Name>
    <LastEdit Timestamp="2025-05-15T09:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSSWY" b2="500 KV" b3="59162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSSWY" b2="500 KV" b3="XT591" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNSSWY" b2="500 KV" b3="591" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAWLINGS" b2="500 KV" b3="59192-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAWLINGS" b2="500 KV" b3="59192-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84380</SeqNum>
    <Name>L230.Hudson-SouthWaterfront.H2313</Name>
    <LastEdit Timestamp="2024-08-15T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="17-18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="2-17" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUDSON" b2="230 KV" b3="HUD-SWAH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="230 KV" b3="SECT 4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="230 KV" b3="SECT 5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84450</SeqNum>
    <Name>138/69.Seaman.T5</Name>
    <LastEdit Timestamp="2024-08-15T10:40:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEAMAN" b2="69 KV" b3="65" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEAMAN" b2="138 KV" b3="T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEAMAN" b2="138 KV" b3="XT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84480</SeqNum>
    <Name>L138.Amos-Lanham-Sisson</Name>
    <LastEdit Timestamp="2024-12-12T13:19:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="138 KV" b3="AMO-LAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LANHAM1" b2="138 KV" b3="COLUMBIA" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANHAM1" b2="138 KV" b3="LAN-SIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SISSON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SISSON" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84490</SeqNum>
    <Name>L500.Fentress-Yadkin.588</Name>
    <LastEdit Timestamp="2026-06-05T12:28:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="500 KV" b3="58822-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="500 KV" b3="58822-7" />
      <ContingencyEquipment Action="L" Type="LN" b1="FENTRES4" b2="500 KV" b3="588A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="500 KV" b3="H2T588" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="500 KV" b3="H5T588" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84520</SeqNum>
    <Name>L138.Elk-Corwin</Name>
    <LastEdit Timestamp="2024-08-16T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORWIN" b2="138 KV" b3="COR-ELK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CORWIN" b2="138 KV" b3="GM2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORWIN" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CORWIN" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELK" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84600</SeqNum>
    <Name>L230.Cartanza-Garrison.23025</Name>
    <LastEdit Timestamp="2024-08-16T14:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTANZA" b2="230 KV" b3="234" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTANZA" b2="230 KV" b3="235" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CARTANZA" b2="18 KV" b3="GARISON2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CARTANZA" b2="13.8 KV" b3="GARRISON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTANZA" b2="230 KV" b3="HI CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTANZA" b2="230 KV" b3="HI GSU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARTANZA" b2="230 KV" b3="LD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84610</SeqNum>
    <Name>Garrison.CC</Name>
    <LastEdit Timestamp="2024-08-16T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CARTANZA" b2="18 KV" b3="GARISON2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CARTANZA" b2="13.8 KV" b3="GARRISON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTANZA" b2="230 KV" b3="HI CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTANZA" b2="230 KV" b3="HI GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84620</SeqNum>
    <Name>Fanwood-FrontSt.R-2323</Name>
    <LastEdit Timestamp="2024-08-16T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FANWOOD" b2="230 KV" b3="FAN-FRO" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FANWOOD" b2="230 KV" b3="R-2323" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTST" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTST" b2="230 KV" b3="2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84640</SeqNum>
    <Name>138/69.Adams.T3</Name>
    <LastEdit Timestamp="2024-09-13T09:56:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSAEP" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSAEP" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSAEP" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSAEP" b2="69 KV" b3="F2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ADAMSAEP" b2="138 KV" b3="XF3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84650</SeqNum>
    <Name>L138.Adams-Seaman</Name>
    <LastEdit Timestamp="2024-08-16T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ADAMSAEP" b2="138 KV" b3="ADA-SEA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSAEP" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSAEP" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEAMAN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEAMAN" b2="138 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84680</SeqNum>
    <Name>L138.Sundial-CranyRoad</Name>
    <LastEdit Timestamp="2026-02-26T09:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANYROA" b2="138 KV" b3="A000A5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANYROA" b2="138 KV" b3="A000A8" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRANYROA" b2="138 KV" b3="CRA-SUND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNDIAL" b2="138 KV" b3="R CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84690</SeqNum>
    <Name>L138.KanawhaRiver-Garrison-RH-Sundial.2</Name>
    <LastEdit Timestamp="2024-08-16T14:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GARRISON" b2="138 KV" b3="ELKRUN" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARRISON" b2="138 KV" b3="GAR-ROC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANAWHAR" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARRISON" b2="138 KV" b3="GAR-KAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKHOUS" b2="138 KV" b3="REPUBLIC" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUNDIAL" b2="138 KV" b3="ROC-SUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNDIAL" b2="138 KV" b3="N CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84700</SeqNum>
    <Name>L138.Baileysville-Kopperston-LaceyBranch</Name>
    <LastEdit Timestamp="2025-09-03T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAILEYSV" b2="138 KV" b3="BAI-KOP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAILEYSV" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="L" Type="LN" b1="KOPPERST" b2="138 KV" b3="KOP-LAC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KOPPERST" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACEYBRA" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84710</SeqNum>
    <Name>L138.NorthProctorville-Windsor-NCrownCity</Name>
    <LastEdit Timestamp="2024-08-16T14:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NCROWNCI" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="L" Type="LN" b1="NCROWNCI" b2="138 KV" b3="NCR-WIN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NPROCTO2" b2="138 KV" b3="NPR-WIN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WINDSOOP" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84730</SeqNum>
    <Name>L138.SoftShell-Harbertm-Spicewoo</Name>
    <LastEdit Timestamp="2024-08-16T14:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SOFTSHEL" b2="138 KV" b3="HAR-SOF" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARBERTM" b2="138 KV" b3="HAR-SPI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOFTSHEL" b2="138 KV" b3="J CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPICEWOO" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84770</SeqNum>
    <Name>345/138.DavisCreek.TR84</Name>
    <LastEdit Timestamp="2024-11-04T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="345 KV" b3="TR84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="86 DAVIS" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="86 DAVIS" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="86 DAVIS" b2="138 KV" b3="TR84CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84790</SeqNum>
    <Name>L138.199KensingtonAve-K4PilotTownship</Name>
    <LastEdit Timestamp="2024-08-16T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="199 KENS" b2="138 KV" b3="L19901" />
      <ContingencyEquipment Action="L" Type="LN" b1="199 KENS" b2="138 KV" b3="19901" />
      <ContingencyEquipment Action="X" Type="XF" b1="938 K4PI" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="938 K4PI" b2="138 KV" b3="TR1CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84800</SeqNum>
    <Name>L138.FireBrick-MillBrookPark</Name>
    <LastEdit Timestamp="2024-08-16T14:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FIREBRIK" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIREBRIK" b2="138 KV" b3="FIR-MIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLBROO" b2="138 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84810</SeqNum>
    <Name>138/69.Hiple.T4 (NIPSCO)</Name>
    <LastEdit Timestamp="2024-11-18T08:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="138 KV" b3="138-103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="138 KV" b3="13809" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="69 KV" b3="4_XFM_CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIPLE" b2="138 KV" b3="NO_4_XFM" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HIPLE" b2="138 KV" b3="S1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HIPLE" b2="138 KV" b3="S2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84820</SeqNum>
    <Name>138/69.Hiple.T3 (NIPSCO)</Name>
    <LastEdit Timestamp="2024-11-18T08:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="138 KV" b3="1_XFM_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="138 KV" b3="2_XFM_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="69 KV" b3="3_XFM_CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIPLE" b2="138 KV" b3="NO_3_XFM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84830</SeqNum>
    <Name>L138.Desoto-SelmaParker</Name>
    <LastEdit Timestamp="2025-07-31T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="M2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SELMAPAR" b2="138 KV" b3="A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SELMAPAR" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DESOTO" b2="138 KV" b3="DES-SEL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84840</SeqNum>
    <Name>L138.91 Cargo-431 Shorewood.9117</Name>
    <LastEdit Timestamp="2024-11-21T14:41:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="431 SHOR" b2="138 KV" b3="91170908" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="431 SHOR" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="431 SHOR" b2="138 KV" b3="L9117" />
      <ContingencyEquipment Action="OP" Type="CB" b1="91 CARGO" b2="138 KV" b3="L9117" />
      <ContingencyEquipment Action="L" Type="LN" b1="9117" b2="138 KV" b3="9117 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="431 SHOR" b2="138 KV" b3="9117 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="9117" b2="138 KV" b3="9117 Z2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="9117" b2="138 KV" b3="J401 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84860</SeqNum>
    <Name>L345.Covert-Segreto</Name>
    <LastEdit Timestamp="2025-12-18T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="345 KV" b3="277" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="345 KV" b3="5060" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="345 KV" b3="6010" />
      <ContingencyEquipment Action="L" Type="LN" b1="COVERT" b2="345 KV" b3="COV-SEGR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEGRETO" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEGRETO" b2="345 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84870</SeqNum>
    <Name>L230.Chinquapin-Tarboro.2177</Name>
    <LastEdit Timestamp="2024-08-16T14:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHINQUPN" b2="230 KV" b3="21602177" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHINQUPN" b2="230 KV" b3="2177A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHINQUPN" b2="230 KV" b3="H1T2177" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TARBORO" b2="230 KV" b3="229T2177" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TARBORO" b2="230 KV" b3="H472" />
      <ContingencyEquipment Action="X" Type="XF" b1="TARBORO" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84880</SeqNum>
    <Name>Chinquapin.SP</Name>
    <LastEdit Timestamp="2026-01-12T11:48:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CHINQUPN" b2="23 KV" b3="CONET2SP" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHINQUPN" b2="230 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHINQUPN" b2="230 KV" b3="H1T2160" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHINQUPN" b2="230 KV" b3="H1T2177" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84900</SeqNum>
    <Name>L138.OhioCentral-Philo</Name>
    <LastEdit Timestamp="2024-08-16T14:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="L" Type="LN" b1="OHIOCENT" b2="138 KV" b3="OHI-PHI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHILO" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84910</SeqNum>
    <Name>L138.Arboles-Wakefield-SLucasville</Name>
    <LastEdit Timestamp="2026-01-09T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARBOLES" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARBOLES" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARBOLES" b2="138 KV" b3="ARB-WAKE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLUCASVI" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="SLUCASVI" b2="138 KV" b3="SLU-WAK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAKEFIEL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84940</SeqNum>
    <Name>L230.Fredericksburg-CranesCorner.2157</Name>
    <LastEdit Timestamp="2024-08-16T14:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANESCR" b2="230 KV" b3="21042157" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRANESCR" b2="230 KV" b3="2157A" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRANESCR" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRDRKSBG" b2="230 KV" b3="215742CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRDRKSBG" b2="230 KV" b3="XT2157" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84980</SeqNum>
    <Name>L138.Grandview-Clifftop-RaleighCountyAirport</Name>
    <LastEdit Timestamp="2026-05-21T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLIFFTOP" b2="138 KV" b3="CLI-RALE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLIFFTOP" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLIFFTOP" b2="138 KV" b3="CLI-GRA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDVAP" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RALEIGHC" b2="138 KV" b3="A002V5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>84990</SeqNum>
    <Name>L138.Grandview-Hinton</Name>
    <LastEdit Timestamp="2024-08-16T14:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GRANDVAP" b2="138 KV" b3="GRA-HIN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDVAP" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINTON" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85000</SeqNum>
    <Name>138/34.EastElkhart.T3</Name>
    <LastEdit Timestamp="2025-04-14T16:46:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="34 KV" b3="N" />
      <ContingencyEquipment Action="X" Type="XF" b1="EELKHART" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85010</SeqNum>
    <Name>138/69.HarrisCS.TR2</Name>
    <LastEdit Timestamp="2025-10-14T18:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HARRISCS" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISCS" b2="138 KV" b3="XB2H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISCS" b2="69 KV" b3="XB2L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85020</SeqNum>
    <Name>L138.Bain-Kenosha (WISC)</Name>
    <LastEdit Timestamp="2025-12-16T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KENOSHA" b2="138 KV" b3="38852393" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAIN" b2="138 KV" b3="9317" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENOSHA" b2="138 KV" b3="9413" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85060</SeqNum>
    <Name>L138.WestLancaster-Hocking</Name>
    <LastEdit Timestamp="2024-08-16T14:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOCKING" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOCKING" b2="138 KV" b3="HOC-WLA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLANCAST" b2="138 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85080</SeqNum>
    <Name>L138.MattFunk-TechDrive</Name>
    <LastEdit Timestamp="2024-08-19T16:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TECHDRIV" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="L" Type="LN" b1="MATTFUN2" b2="138 KV" b3="MAT-TEC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85090</SeqNum>
    <Name>L230.Elimsport-Lycoming.1 + 230/69.Lycoming.1</Name>
    <LastEdit Timestamp="2025-01-14T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMSPOR" b2="230 KV" b3="ELI-LYC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMSPOR" b2="230 KV" b3="LYCOMNG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMSPOR" b2="230 KV" b3="LYM_SEA" />
      <ContingencyEquipment Action="X" Type="XF" b1="LYCOMING" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="TRAN1_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="TRAN1_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85110</SeqNum>
    <Name>L69.Argentum-Leon</Name>
    <LastEdit Timestamp="2026-01-09T15:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARGNT_EK" b2="69 KV" b3="ARG-LOWG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGNT_EK" b2="69 KV" b3="CB_624" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARTERCJ" b2="69 KV" b3="CAR-PACT" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYSONJ" b2="69 KV" b3="GRA-LEON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEON_EKP" b2="69 KV" b3="CB604" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOWGAP_T" b2="69 KV" b3="LOW-WARN" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYSONJ" b2="69 KV" b3="GRA-PACT" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARTERCJ" b2="69 KV" b3="CAR-WARN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85120</SeqNum>
    <Name>L230.Elimsport-Sunbury</Name>
    <LastEdit Timestamp="2024-10-25T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMSPOR" b2="230 KV" b3="ELI-SUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMSPOR" b2="230 KV" b3="SUNBECB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMSPOR" b2="230 KV" b3="SUNBWCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="ELIM_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="ELIM_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85140</SeqNum>
    <Name>L138.Bluerace-SummerField</Name>
    <LastEdit Timestamp="2024-12-05T16:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUERACE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUERACE" b2="138 KV" b3="BLU-SUM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMERFI" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85150</SeqNum>
    <Name>L138.SunnySide-Carrollton</Name>
    <LastEdit Timestamp="2024-08-22T11:07:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARROLLT" b2="138 KV" b3="CAR-SUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARROLLT" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNNYSOP" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85160</SeqNum>
    <Name>L138.Bosserman-BOCGas</Name>
    <LastEdit Timestamp="2024-08-22T10:53:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BOCGASE2" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOCGASE2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOCGASE2" b2="138 KV" b3="BOC-BOS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOCGASE2" b2="12 KV" b3="XF1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="138 KV" b3="C1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85200</SeqNum>
    <Name>L138.Blendon-Corridor</Name>
    <LastEdit Timestamp="2024-08-19T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLENDON" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLENDON" b2="138 KV" b3="BLE-COR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLENDON" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="105C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="105S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85210</SeqNum>
    <Name>L138.Hernshaw-Ruth</Name>
    <LastEdit Timestamp="2024-08-19T16:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HERNSHAW" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="HERNSHAW" b2="138 KV" b3="HER-RUT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUTH" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85220</SeqNum>
    <Name>L138.Ruth-Turner</Name>
    <LastEdit Timestamp="2024-08-19T16:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RUTH" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUTH" b2="138 KV" b3="RUT-TUR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RUTH" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="D1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85230</SeqNum>
    <Name>L138.WildCat-Emerald-Sardinia</Name>
    <LastEdit Timestamp="2025-12-30T11:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EMERALD1" b2="138 KV" b3="EME-SARD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EMERALD1" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SARDINIA" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILDCAT" b2="138 KV" b3="B-CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="EMERALD1" b2="138 KV" b3="EME-WIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILDCAT" b2="138 KV" b3="H001M5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85250</SeqNum>
    <Name>L230.Dranesville-HerndonPark-SterlingPark.2079</Name>
    <LastEdit Timestamp="2024-08-22T11:07:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DRANESVL" b2="230 KV" b3="20622079" />
      <ContingencyEquipment Action="L" Type="LN" b1="DRANESVL" b2="230 KV" b3="2079C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRANESVL" b2="230 KV" b3="H142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRANESVL" b2="230 KV" b3="H342" />
      <ContingencyEquipment Action="X" Type="XF" b1="DRANESVL" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DRANESVL" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DRANESVL" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DRANESVL" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERNDNPK" b2="230 KV" b3="H282" />
      <ContingencyEquipment Action="X" Type="XF" b1="HERNDNPK" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HERNDNPK" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HERNDNPK" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HERNDNPK" b2="34.5 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERLNPK" b2="230 KV" b3="20792150" />
      <ContingencyEquipment Action="L" Type="LN" b1="HERNDNPK" b2="230 KV" b3="2079B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERLNPK" b2="230 KV" b3="H272CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="STERLNPK" b2="230 KV" b3="TX_2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STERLNPK" b2="35 KV" b3="TX_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85290</SeqNum>
    <Name>765/138.JacksonsFerry.XF3</Name>
    <LastEdit Timestamp="2024-08-19T15:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="765 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="765 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="R1" />
      <ContingencyEquipment Action="X" Type="XF" b1="JACKSONS" b2="765 KV" b3="XF3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85300</SeqNum>
    <Name>L69.Corson-Court.0720</Name>
    <LastEdit Timestamp="2025-06-23T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORSON" b2="69 KV" b3="COR-COU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORSON" b2="69 KV" b3="OCB L" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COURT" b2="69 KV" b3="DIS L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85320</SeqNum>
    <Name>L138.BearWallow-Faraday</Name>
    <LastEdit Timestamp="2024-12-02T14:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARWALO" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEARWALO" b2="138 KV" b3="BEA-FAR" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEARWALO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARDAY" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85330</SeqNum>
    <Name>L230.CoxsCorner-Lumberton.P-2321</Name>
    <LastEdit Timestamp="2024-08-19T16:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COXSCORN" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COXSCORN" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMBERTO" b2="230 KV" b3="1-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="COXSCORN" b2="230 KV" b3="COX-LUM2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMBERTO" b2="230 KV" b3="SECT1-2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LUMBERTO" b2="230 KV" b3="T12TRANS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LUMBERTO" b2="230 KV" b3="TRANT-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85340</SeqNum>
    <Name>L230.Athenia-Bergen.A2332</Name>
    <LastEdit Timestamp="2025-09-16T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="4-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="2-12" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATHENIA" b2="230 KV" b3="ATH-BERA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85380</SeqNum>
    <Name>L345.Tidd-Holloway</Name>
    <LastEdit Timestamp="2024-08-20T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="345 KV" b3="M1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="AA2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLLOWAY" b2="345 KV" b3="HOL-TID" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85390</SeqNum>
    <Name>345/138.Holloway.TR1</Name>
    <LastEdit Timestamp="2024-08-19T13:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="K5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="K6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="345 KV" b3="M2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOLLOWAY" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85400</SeqNum>
    <Name>L138.FallingBranch-Merrimac</Name>
    <LastEdit Timestamp="2024-08-19T16:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FALLINGB" b2="138 KV" b3="FAL-MER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLINGB" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERRIMAC" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERRIMAC" b2="138 KV" b3="T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85420</SeqNum>
    <Name>L138.SouthBaltimore-WestLancaster</Name>
    <LastEdit Timestamp="2024-08-19T16:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SBALTIMO" b2="138 KV" b3="B CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="SBALTIMO" b2="138 KV" b3="SBA-WLA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLANCAST" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85430</SeqNum>
    <Name>L230.Mackeys-Plymouth-Trowbridge.2126</Name>
    <LastEdit Timestamp="2024-08-22T10:56:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MACKEYS" b2="230 KV" b3="212642" />
      <ContingencyEquipment Action="L" Type="LN" b1="MACKEYS" b2="230 KV" b3="2126A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACKEYS" b2="230 KV" b3="H1T2126" />
      <ContingencyEquipment Action="S" Type="SD" b1="PLYMOUT4" b2="230 KV" b3="2126A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLYMOUT4" b2="230 KV" b3="2126B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUT4" b2="230 KV" b3="H132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYMOUT4" b2="230 KV" b3="H232" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLYMOUT4" b2="230 KV" b3="TX_1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLYMOUT4" b2="35 KV" b3="TX_1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLYMOUT4" b2="230 KV" b3="TX_2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLYMOUT4" b2="35 KV" b3="TX_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="230 KV" b3="20342126" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="230 KV" b3="H1T2126" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85450</SeqNum>
    <Name>L138.Evans-Goodyear-Hayes-EastAkron</Name>
    <LastEdit Timestamp="2025-06-20T15:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EAKRON" b2="138 KV" b3="253" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EAKRON" b2="138 KV" b3="A256" />
      <ContingencyEquipment Action="L" Type="LN" b1="EAKRON" b2="138 KV" b3="EAK-HAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVANSOE" b2="138 KV" b3="B105" />
      <ContingencyEquipment Action="L" Type="LN" b1="EVANSOE" b2="138 KV" b3="EVA-GOO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOODYROE" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOODYROE" b2="138 KV" b3="GOO-HAY" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOODYROE" b2="138 KV" b3="LD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAYELMRZ" b2="138 KV" b3="HAYES" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85460</SeqNum>
    <Name>L69.Buckskin-Greenfield</Name>
    <LastEdit Timestamp="2024-10-29T16:31:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKSKIN" b2="69 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKSKIN" b2="69 KV" b3="BUC-GRE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKSKIN" b2="69 KV" b3="H005F5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENFIE" b2="69 KV" b3="JC-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENFIE" b2="69 KV" b3="JC-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85480</SeqNum>
    <Name>L138.Amos-Dalewod-Chemical</Name>
    <LastEdit Timestamp="2024-08-19T15:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHEMICAL" b2="138 KV" b3="CHE-DAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="138 KV" b3="U" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="138 KV" b3="AMO-DAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DALEWOOD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85510</SeqNum>
    <Name>L69.Easton-EastMuni.6772 + EastMuni.G1</Name>
    <LastEdit Timestamp="2024-11-20T16:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="69 KV" b3="7420" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="69 KV" b3="7430" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTON" b2="69 KV" b3="EAS-EMU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTONTP" b2="69 KV" b3="SW_TAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EMUNI" b2="69 KV" b3="E-MUNI" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTONTP" b2="69 KV" b3="EAT-EMU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EMUNI" b2="12 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EMUNI" b2="69 KV" b3="LOAD BKR" />
      <ContingencyEquipment Action="X" Type="XF" b1="EMUNI" b2="69 KV" b3="T4_5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85520</SeqNum>
    <Name>L230.Liberty-Railroad.2080</Name>
    <LastEdit Timestamp="2025-07-01T14:43:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LIBERTY1" b2="230 KV" b3="2080" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="230 KV" b3="20802187" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="230 KV" b3="20802228" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAILRDDP" b2="230 KV" b3="208002-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAILRDDP" b2="230 KV" b3="208002-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85530</SeqNum>
    <Name>L230.Gainesville-Railroad.2151</Name>
    <LastEdit Timestamp="2024-08-19T16:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAINESVL" b2="230 KV" b3="20302151" />
      <ContingencyEquipment Action="L" Type="LN" b1="GAINESVL" b2="230 KV" b3="2151A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAINESVL" b2="230 KV" b3="H3T2151" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAILRDDP" b2="230 KV" b3="215102-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAILRDDP" b2="230 KV" b3="215102-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85540</SeqNum>
    <Name>230/34.Northeast.TX6</Name>
    <LastEdit Timestamp="2025-07-31T15:29:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="NEAST" b2="35 KV" b3="BFI LF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="230 KV" b3="H662" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEAST" b2="230 KV" b3="TX6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEAST" b2="35 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85550</SeqNum>
    <Name>L230.Moyock-Sligo-Shawboro.2192</Name>
    <LastEdit Timestamp="2024-11-20T13:42:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOYOCK" b2="230 KV" b3="219202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOYOCK" b2="230 KV" b3="21922235" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWBORO" b2="230 KV" b3="20642192" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWBORO" b2="230 KV" b3="20732192" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHAWBORO" b2="230 KV" b3="2192" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOYOCK" b2="230 KV" b3="2192A" />
      <ContingencyEquipment Action="X" Type="XF" b1="SLIGO" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SLIGO" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85560</SeqNum>
    <Name>L230.PuddingRidge-Hickory-Fentress.2087</Name>
    <LastEdit Timestamp="2025-10-29T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="208722" />
      <ContingencyEquipment Action="L" Type="LN" b1="HICKORY" b2="230 KV" b3="2087B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="W22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORY" b2="230 KV" b3="H132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORY" b2="230 KV" b3="H432" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUDDNRID" b2="230 KV" b3="20872235" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUDDNRID" b2="230 KV" b3="208782" />
      <ContingencyEquipment Action="L" Type="LN" b1="HICKORY" b2="230 KV" b3="HIC-PUDD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85570</SeqNum>
    <Name>L230.Dooms-Lexington.2168</Name>
    <LastEdit Timestamp="2025-03-18T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DOOMS4" b2="230 KV" b3="2168" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="216842" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOOMS4" b2="230 KV" b3="WT2168" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="230 KV" b3="216802" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85590</SeqNum>
    <Name>L69.Freedom-Rosslyn.174</Name>
    <LastEdit Timestamp="2024-12-31T13:49:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEDOM1" b2="69 KV" b3="17432" />
      <ContingencyEquipment Action="L" Type="LN" b1="FREEDOM1" b2="69 KV" b3="174B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEDOM1" b2="69 KV" b3="174T1003" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSLYN" b2="69 KV" b3="143T174" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSLYN" b2="69 KV" b3="174T178" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROSLYN" b2="13 KV" b3="TX4" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROSLYN" b2="69 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85600</SeqNum>
    <Name>L69.Freedom-Pentagon.1003</Name>
    <LastEdit Timestamp="2025-03-26T10:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEDOM1" b2="69 KV" b3="100332" />
      <ContingencyEquipment Action="L" Type="LN" b1="FREEDOM1" b2="69 KV" b3="1003A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEDOM1" b2="69 KV" b3="174T1003" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="69 KV" b3="100322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="69 KV" b3="XT1003" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85610</SeqNum>
    <Name>500/230.Clover.T7</Name>
    <LastEdit Timestamp="2025-05-13T20:55:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="500 KV" b3="H7T556" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="L712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="L7T2281" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVER" b2="500 KV" b3="TX7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85620</SeqNum>
    <Name>230/115.Mackeys.TX1</Name>
    <LastEdit Timestamp="2024-08-19T13:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MACKEYS" b2="230 KV" b3="H142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACKEYS" b2="115 KV" b3="L1T101" />
      <ContingencyEquipment Action="X" Type="XF" b1="MACKEYS" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85630</SeqNum>
    <Name>230/115.Mackeys.TX2</Name>
    <LastEdit Timestamp="2024-08-19T13:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MACKEYS" b2="230 KV" b3="H242" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACKEYS" b2="115 KV" b3="L2T101" />
      <ContingencyEquipment Action="X" Type="XF" b1="MACKEYS" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85640</SeqNum>
    <Name>230/115.Yadkin.Tx6</Name>
    <LastEdit Timestamp="2024-08-19T13:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="H612" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="115 KV" b3="L6T46" />
      <ContingencyEquipment Action="X" Type="XF" b1="YADKIN4" b2="230 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85670</SeqNum>
    <Name>L230.Hudson-Belleville.I-2314</Name>
    <LastEdit Timestamp="2024-08-19T16:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELLEVIL" b2="230 KV" b3="220-2AB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLEVIL" b2="230 KV" b3="BEL-HUDX" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BELLEVIL" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEVIL" b2="230 KV" b3="SECT2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85690</SeqNum>
    <Name>138/13.Motiva.T5 &amp; L13.Motiva-DelawareCity</Name>
    <LastEdit Timestamp="2025-05-22T12:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="13 KV" b3="T5A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTIVA" b2="138 KV" b3="133 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTIVA" b2="138 KV" b3="134 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELA DPL" b2="13 KV" b3="DEL-MOT1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOTIVA" b2="138 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85700</SeqNum>
    <Name>230/115.NorthEast.230-2</Name>
    <LastEdit Timestamp="2025-08-22T10:34:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="110581" />
      <ContingencyEquipment Action="X" Type="XF" b1="NORTHEAS" b2="230 KV" b3="230-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="230 KV" b3="2337CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="230 KV" b3="2339CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="582_-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="583B_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="592-2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85710</SeqNum>
    <Name>230/115.NorthEast.230-3</Name>
    <LastEdit Timestamp="2025-08-22T10:36:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="110591" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="NORTHEAS" b2="230 KV" b3="230-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="230 KV" b3="2315CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="230 KV" b3="2317CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="592-3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="FB10_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="FB18_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85730</SeqNum>
    <Name>L138.Campbell(FE)-Keisters(APS)</Name>
    <LastEdit Timestamp="2024-08-20T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPOHED" b2="138 KV" b3="B82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPOHED" b2="138 KV" b3="B90" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMPOHED" b2="138 KV" b3="CAM-KEI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEISTERS" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85740</SeqNum>
    <Name>L138.Campbell-McDowell</Name>
    <LastEdit Timestamp="2024-08-19T16:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPOHED" b2="138 KV" b3="B73" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPOHED" b2="138 KV" b3="B82" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMPOHED" b2="138 KV" b3="CAM-MCD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCDOWLOE" b2="138 KV" b3="B90" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85750</SeqNum>
    <Name>L138.NBeckley-JehuBranch-Mabscott-TamsMount</Name>
    <LastEdit Timestamp="2025-05-05T12:36:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JEHUBRAN" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="JEHUBRAN" b2="138 KV" b3="JEH-MABS" />
      <ContingencyEquipment Action="L" Type="LN" b1="MABSCOTT" b2="138 KV" b3="MAB-TAMS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MABSCOTT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBECKLEY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="JEHUBRAN" b2="138 KV" b3="JEH-NBE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAMSMOUN" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAMSMOUN" b2="138 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85770</SeqNum>
    <Name>345/138.Kammer.T303</Name>
    <LastEdit Timestamp="2024-08-19T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="345 KV" b3="EE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="345 KV" b3="EE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="G CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="G1 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="KAMMER2" b2="345 KV" b3="TR303" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85780</SeqNum>
    <Name>L230.Hoboken-49thSt-Homestead.Penhorn.Y2225</Name>
    <LastEdit Timestamp="2024-08-22T10:58:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="49STREET" b2="230 KV" b3="49T-HOM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOBOKEN" b2="230 KV" b3="2-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="49STREET" b2="230 KV" b3="49T-HOB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOBOKEN" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOMESTEA" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOMESTEA" b2="230 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMESTEA" b2="230 KV" b3="TRAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMESTEA" b2="230 KV" b3="TRAN3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENHORN" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOMESTEA" b2="230 KV" b3="HOM-PEN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85790</SeqNum>
    <Name>L138.Sporn-SpornSouth</Name>
    <LastEdit Timestamp="2024-08-21T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="H1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85800</SeqNum>
    <Name>L345.Bayshore-Lallendorf.1</Name>
    <LastEdit Timestamp="2024-08-19T16:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="345 KV" b3="41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="345 KV" b3="42" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYSHOR2" b2="345 KV" b3="BAY-LAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LALLENDO" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LALLENDO" b2="345 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85810</SeqNum>
    <Name>L345.Bayshore-Lallendorf.2</Name>
    <LastEdit Timestamp="2024-08-19T16:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="345 KV" b3="40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="345 KV" b3="44" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYSHOR2" b2="345 KV" b3="BAY-LAL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LALLENDO" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LALLENDO" b2="345 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85820</SeqNum>
    <Name>L345.Lallendorf-Monroe[DET].Tie</Name>
    <LastEdit Timestamp="2025-03-05T16:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LALLENDO" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LALLENDO" b2="345 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="LALLENDO" b2="345 KV" b3="LAL-MON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONROE" b2="345 KV" b3="AM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONROE" b2="345 KV" b3="AT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85830</SeqNum>
    <Name>L345.FostoriaCentral-Lallendorf</Name>
    <LastEdit Timestamp="2024-08-20T12:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTORIA" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTORIA" b2="345 KV" b3="FOS-LAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LALLENDO" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LALLENDO" b2="345 KV" b3="B6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85840</SeqNum>
    <Name>L345.Lallendorf-OregonEnergy</Name>
    <LastEdit Timestamp="2024-08-22T11:13:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LALLENDO" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LALLENDO" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="LALLENDO" b2="345 KV" b3="LAL-ORE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OREGONEN" b2="19 KV" b3="AUXA LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OREGONEN" b2="19 KV" b3="AUXB LD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OREGONEN" b2="19 KV" b3="CTG11" />
      <ContingencyEquipment Action="X" Type="XF" b1="OREGONEN" b2="345 KV" b3="CTG11GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OREGONEN" b2="19 KV" b3="CTG12" />
      <ContingencyEquipment Action="X" Type="XF" b1="OREGONEN" b2="345 KV" b3="CTG12GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OREGONEN" b2="345 KV" b3="G13" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OREGONEN" b2="19 KV" b3="ST10" />
      <ContingencyEquipment Action="X" Type="XF" b1="OREGONEN" b2="345 KV" b3="ST10GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85870</SeqNum>
    <Name>OregonEnergy.ST10</Name>
    <LastEdit Timestamp="2024-08-20T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OREGONEN" b2="345 KV" b3="G10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OREGONEN" b2="19 KV" b3="ST10" />
      <ContingencyEquipment Action="X" Type="XF" b1="OREGONEN" b2="345 KV" b3="ST10GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85880</SeqNum>
    <Name>L345.LeroyCenter-Perry</Name>
    <LastEdit Timestamp="2025-08-25T13:57:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="345 KV" b3="B73" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="345 KV" b3="B74" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEROYCEN" b2="345 KV" b3="LER-PER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85890</SeqNum>
    <Name>L345.Harding-LeroyCenter</Name>
    <LastEdit Timestamp="2025-03-14T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="345 KV" b3="B26" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDING2" b2="345 KV" b3="HAR-LER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="345 KV" b3="B71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="345 KV" b3="B72" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85900</SeqNum>
    <Name>345/138.LeroyCenter.TR1</Name>
    <LastEdit Timestamp="2024-08-20T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="345 KV" b3="B71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="345 KV" b3="B73" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B86" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEROYCEN" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85910</SeqNum>
    <Name>345/138.LeroyCenter.TR2</Name>
    <LastEdit Timestamp="2024-08-20T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="345 KV" b3="B72" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="345 KV" b3="B74" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B87" />
      <ContingencyEquipment Action="X" Type="XF" b1="LEROYCEN" b2="345 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85920</SeqNum>
    <Name>L138.PotterSS-NovaChemical.1</Name>
    <LastEdit Timestamp="2025-04-15T13:43:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NOVACHEM" b2="138 KV" b3="HI CB1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NOVACHEM" b2="13 KV" b3="LOAD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NOVACHEM" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NOVACHEM" b2="138 KV" b3="NOV-POT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE8-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85930</SeqNum>
    <Name>L138.Potter-Valley.Z-181</Name>
    <LastEdit Timestamp="2024-08-20T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="POTTERSS" b2="138 KV" b3="POT-VAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE4-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE6-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="138 KV" b3="Z-181" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85940</SeqNum>
    <Name>L138.Potter-Valley.Z-183</Name>
    <LastEdit Timestamp="2024-08-20T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="POTTERSS" b2="138 KV" b3="POT-VAL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE10-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="138 KV" b3="Z-183" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85960</SeqNum>
    <Name>138/69/34.DeerCreek.T1</Name>
    <LastEdit Timestamp="2025-12-17T11:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DEERCREE" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="DEERCREE" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="DEERCREE" b2="34 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCREE" b2="138 KV" b3="AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCREE" b2="69 KV" b3="BC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCREE" b2="69 KV" b3="BD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCREE" b2="34 KV" b3="V" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>85970</SeqNum>
    <Name>L345.BrunotIsland-Tecumseh-Carson.302</Name>
    <LastEdit Timestamp="2025-01-24T14:31:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNOTIS" b2="345 KV" b3="BRU-TEC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="345 KV" b3="TEC302" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARS DUQ" b2="345 KV" b3="302" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARS DUQ" b2="345 KV" b3="CAR-TEC" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="TECUMSEH" b2="345 KV" b3="R1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TECUMSEH" b2="345 KV" b3="REAC1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86000</SeqNum>
    <Name>L345.HomerCity-PierceBrook</Name>
    <LastEdit Timestamp="2025-03-28T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="345 KV" b3="B304" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="345 KV" b3="B305" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOMERCIT" b2="345 KV" b3="HOM-PIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="345 KV" b3="B94" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86010</SeqNum>
    <Name>L345.PierceBrook-FiveMile[NYISO]</Name>
    <LastEdit Timestamp="2024-08-20T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="5MILE" b2="345 KV" b3="5MI-PIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="5MILE" b2="345 KV" b3="797" />
      <ContingencyEquipment Action="OP" Type="CB" b1="5MILE" b2="345 KV" b3="800" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="345 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86020</SeqNum>
    <Name>345/230.PierceBrook.TR1</Name>
    <LastEdit Timestamp="2025-10-20T10:31:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="230 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="230 KV" b3="B9" />
      <ContingencyEquipment Action="X" Type="XF" b1="PIERCEBR" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86040</SeqNum>
    <Name>L230.LewisRun-PierceBrook</Name>
    <LastEdit Timestamp="2026-04-01T13:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISRN" b2="230 KV" b3="B62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISRN" b2="230 KV" b3="B63" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEWISRN" b2="230 KV" b3="LEW-PIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="230 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="230 KV" b3="B8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86050</SeqNum>
    <Name>230/115.PierceBrook.TR2</Name>
    <LastEdit Timestamp="2024-08-20T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="230 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="115 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="115 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="230 KV" b3="B9" />
      <ContingencyEquipment Action="X" Type="XF" b1="PIERCEBR" b2="230 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86070</SeqNum>
    <Name>L115.FarmersValley-PierceBrook</Name>
    <LastEdit Timestamp="2024-08-20T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMERSV" b2="115 KV" b3="B26" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMERSV" b2="115 KV" b3="FAR-PIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="115 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="115 KV" b3="B15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86090</SeqNum>
    <Name>L138.Fairview-FlatRun-Metz-RichwoodHill.76</Name>
    <LastEdit Timestamp="2024-08-22T11:09:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FAIR APS" b2="138 KV" b3="FAI-FLA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAIR APS" b2="138 KV" b3="FLATRRES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIR APS" b2="138 KV" b3="FLATRUN" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLATRUN" b2="138 KV" b3="FLA-MET" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLATRUN" b2="138 KV" b3="T1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLATRUN" b2="138 KV" b3="T1_2 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="METZ" b2="138 KV" b3="MET-RIC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="METZ" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RICHWDHL" b2="138 KV" b3="A1051" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHWDHL" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHWDHL" b2="138 KV" b3="B6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86110</SeqNum>
    <Name>RichwoodHill.SVC</Name>
    <LastEdit Timestamp="2024-08-20T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHWDHL" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RICHWDHL" b2="138 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86140</SeqNum>
    <Name>L345.Byron-Wayne.0626</Name>
    <LastEdit Timestamp="2025-08-22T10:28:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="144 WAYN" b2="345 KV" b3="0626" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="345 KV" b3="7-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="345 KV" b3="BT5-8D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="6 BYRON" b2="345 KV" b3="L0626" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86150</SeqNum>
    <Name>L500.BrunswickSS-BrunswickCounty.509 &amp; Units</Name>
    <LastEdit Timestamp="2025-04-01T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNSCOL" b2="500 KV" b3="1A" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNSCOL" b2="500 KV" b3="1B" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNSCOL" b2="500 KV" b3="1C" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNSCOL" b2="500 KV" b3="1S" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRUNSCOL" b2="21 KV" b3="BRUNSCT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRUNSCOL" b2="21 KV" b3="BRUNSCT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRUNSCOL" b2="21 KV" b3="BRUNSCT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRUNSCOL" b2="21 KV" b3="BRUNSST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSCOL" b2="500 KV" b3="G1A42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSCOL" b2="500 KV" b3="G1B42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSCOL" b2="500 KV" b3="G1C42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSCOL" b2="500 KV" b3="G1S42" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNSCOL" b2="21 KV" b3="LOAD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNSCOL" b2="21 KV" b3="LOAD2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNSCOL" b2="21 KV" b3="LOAD3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNSCOL" b2="500 KV" b3="509" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSSWY" b2="500 KV" b3="50962" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSSWY" b2="500 KV" b3="509T570" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86160</SeqNum>
    <Name>L500.SkiffesCreek-Surry.582</Name>
    <LastEdit Timestamp="2024-12-03T14:04:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SKFFSCRK" b2="500 KV" b3="582A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="500 KV" b3="H1T582" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="500 KV" b3="H2T582" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="500 KV" b3="531T582" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="500 KV" b3="58202" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86180</SeqNum>
    <Name>L230.Sewaren-Woodbrdge-Metuchen.T-2325</Name>
    <LastEdit Timestamp="2025-06-17T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="1-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="11-12" />
      <ContingencyEquipment Action="L" Type="LN" b1="METUCHEN" b2="230 KV" b3="MET-WOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEWAREN" b2="230 KV" b3="SEW-WOO3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODBRID" b2="230 KV" b3="T3LD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODBRID" b2="230 KV" b3="WOODB2SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODBRID" b2="230 KV" b3="WOODBRSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86220</SeqNum>
    <Name>L230.Greenbrook-LakeNelson</Name>
    <LastEdit Timestamp="2025-01-27T15:18:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENBRO" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENBRO" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENBRO" b2="230 KV" b3="GRE-LAK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LAKENELS" b2="230 KV" b3="LAKENESP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAKENELS" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAKENELS" b2="230 KV" b3="T-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKENELS" b2="230 KV" b3="W1037 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86230</SeqNum>
    <Name>ErieSouth.SVC</Name>
    <LastEdit Timestamp="2025-02-20T13:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="230 KV" b3="B133" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ERIES" b2="230 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86240</SeqNum>
    <Name>230/115.Warren.T5</Name>
    <LastEdit Timestamp="2024-08-20T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WARREN" b2="230 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="115 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="230 KV" b3="B43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="230 KV" b3="B53" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86270</SeqNum>
    <Name>L230.Athenia-Saddlebrook.F-2337</Name>
    <LastEdit Timestamp="2024-08-21T15:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="3-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATHENIA" b2="230 KV" b3="ATH-SADF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SADDLEBR" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SADDLEBR" b2="230 KV" b3="4-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86370</SeqNum>
    <Name>L230.Elmont-ShortPump.2103</Name>
    <LastEdit Timestamp="2024-08-22T11:11:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="20322103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELMONT4" b2="230 KV" b3="210392" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHORTPMP" b2="230 KV" b3="20092103" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMONT4" b2="230 KV" b3="2103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHORTPMP" b2="230 KV" b3="H142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHORTPMP" b2="230 KV" b3="H342" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHORTPMP" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHORTPMP" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86420</SeqNum>
    <Name>L230.NorthBergen-Bergen.U-2326</Name>
    <LastEdit Timestamp="2025-09-16T10:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="17-18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="4-18" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERGEN" b2="230 KV" b3="BER-NBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBERGEN" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBERGEN" b2="230 KV" b3="T-20" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NBERGEN" b2="230 KV" b3="T20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86470</SeqNum>
    <Name>L138.Buffington-Webster.6789</Name>
    <LastEdit Timestamp="2024-08-21T14:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="138 KV" b3="932" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEBSTER2" b2="138 KV" b3="967" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEBSTER2" b2="138 KV" b3="968" />
      <ContingencyEquipment Action="L" Type="LN" b1="WEBSTER2" b2="138 KV" b3="BUF-WEB1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86490</SeqNum>
    <Name>L138.CentralHarding-BlkBrch-Hardinsburg(Tie)</Name>
    <LastEdit Timestamp="2025-01-17T15:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLKBRCH" b2="138 KV" b3="HAR-HARD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLKBRCH" b2="138 KV" b3="LD_153" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLKBRCH" b2="138 KV" b3="BLK-BLKB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CNTRLHAR" b2="138 KV" b3="CB804" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CNTRLHAR" b2="138 KV" b3="CB91T" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARDINSB" b2="138 KV" b3="B184_707" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDINSB" b2="138 KV" b3="B184_724" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86500</SeqNum>
    <Name>L138.Fawkes-FawkesLG (Tie)</Name>
    <LastEdit Timestamp="2025-10-16T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKES" b2="138 KV" b3="CB844" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKESLG" b2="138 KV" b3="B102_744" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKESLG" b2="138 KV" b3="B102_749" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAWKES" b2="138 KV" b3="FAW-FAW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86520</SeqNum>
    <Name>L69.LaurelCo-Hopewell-SweetHollow (Tie)</Name>
    <LastEdit Timestamp="2025-01-15T18:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOPEWEL2" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPEWEL2" b2="69 KV" b3="SWE-HOPE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAURELCO" b2="69 KV" b3="CB634" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPEWEL2" b2="69 KV" b3="LAU-HOPE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWEET_HO" b2="69 KV" b3="B215_604" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWEET_HO" b2="69 KV" b3="B215_607" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86540</SeqNum>
    <Name>L69.Hodgenville-Elizabethtown(Tie)</Name>
    <LastEdit Timestamp="2024-08-22T15:33:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZABET" b2="69 KV" b3="B034_654" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELIZABET" b2="69 KV" b3="B034_657" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIZABET" b2="69 KV" b3="ELI-ELI4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELIZBTO4" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIZBTO4" b2="69 KV" b3="HOD-ELIZ" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HODGENSV" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HODGENVL" b2="69 KV" b3="CB614" />
      <ContingencyEquipment Action="L" Type="LN" b1="HODGENSV" b2="69 KV" b3="HOD-HODG" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HODGENVL" b2="69 KV" b3="SW617" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86550</SeqNum>
    <Name>L69.Greenco-Greensburg (Tie)</Name>
    <LastEdit Timestamp="2025-03-18T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCO" b2="69 KV" b3="CB604" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENCO" b2="69 KV" b3="GRE-GREB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENCO" b2="69 KV" b3="SW607" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENSBU" b2="69 KV" b3="B783_615" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86560</SeqNum>
    <Name>L69.Somerset-RusselCo(Tie)</Name>
    <LastEdit Timestamp="2024-08-22T15:37:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSELCO" b2="69 KV" b3="BS55_614" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUSSELCO" b2="69 KV" b3="RUSS-SEW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RUSSELCO" b2="69 KV" b3="SW627" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SEWELLTN" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEWELLTN" b2="69 KV" b3="SEW-UNIO" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SEWELLTN" b2="69 KV" b3="SH_186" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMRST_EK" b2="69 KV" b3="CBS7_664" />
      <ContingencyEquipment Action="L" Type="LN" b1="SMRST_EK" b2="69 KV" b3="SMR-SOME" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMRST_EK" b2="69 KV" b3="SWS7_657" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOMERSE4" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOMERSE4" b2="69 KV" b3="SS6-SOME" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNION_UN" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNION_UN" b2="69 KV" b3="LD_186" />
      <ContingencyEquipment Action="L" Type="LN" b1="UNION_UN" b2="69 KV" b3="UNI-WAIT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAITSBOR" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="SS_615KU" b2="69 KV" b3="SS6-WAIT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86570</SeqNum>
    <Name>L69.GarrardCo-Lancaster (Tie)</Name>
    <LastEdit Timestamp="2024-08-21T15:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GARRD_CO" b2="69 KV" b3="CB614" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARRD_CO" b2="69 KV" b3="GAR-LANC" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GARRD_CO" b2="69 KV" b3="SW617" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANCASTE" b2="69 KV" b3="B137_654" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86580</SeqNum>
    <Name>L69.FawkesLG-Crooksville (Tie)</Name>
    <LastEdit Timestamp="2026-05-08T12:05:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="2BEREKUT" b2="69 KV" b3="DUM1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="2BEREKUT" b2="69 KV" b3="DUMG1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCAN_EK" b2="69 KV" b3="ALC-PPGJ" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCAN_EK" b2="69 KV" b3="ALC-WBE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALCAN_EK" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALCAN_EK" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROOKSVJ" b2="69 KV" b3="CRO-DUN" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROOKSVJ" b2="69 KV" b3="CRO-HICK" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CROOKSVJ" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUNCANLN" b2="69 KV" b3="DUN-FAW" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUNCANLN" b2="69 KV" b3="DUNCANON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKESLG" b2="69 KV" b3="B102_614" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAWKESLG" b2="69 KV" b3="B102_617" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HICKPLNS" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HICKPLNS" b2="69 KV" b3="SH_186" />
      <ContingencyEquipment Action="L" Type="LN" b1="HICKPLNS" b2="69 KV" b3="HIC-PPG2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PPG2" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="PPG2" b2="69 KV" b3="PPG-PPGJ" />
      <ContingencyEquipment Action="L" Type="LN" b1="2BEREKUT" b2="69 KV" b3="BER-PPG1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROOKSVJ" b2="69 KV" b3="CRO-SPED" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPEDWLRD" b2="69 KV" b3="SPEED_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_BEREA" b2="69 KV" b3="S49-634" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="W_BEREA" b2="69 KV" b3="S49-637" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86590</SeqNum>
    <Name>L69.Farley-LaurelCo(Tie)</Name>
    <LastEdit Timestamp="2024-08-22T15:52:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BACONJ" b2="69 KV" b3="LD_184" />
      <ContingencyEquipment Action="L" Type="LN" b1="BACONJ" b2="69 KV" b3="SCO-BACO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARLEY2" b2="69 KV" b3="B128_624" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARLEY2" b2="69 KV" b3="B128_627" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEAVY" b2="69 KV" b3="KEA-KEAJ" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEAVY" b2="69 KV" b3="KEAVYLD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEAVY" b2="69 KV" b3="KEAVYLD2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEAVYJT1" b2="69 KV" b3="E55-615" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEAVY" b2="69 KV" b3="KEA-KEAV" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEAVYJT2" b2="69 KV" b3="KEA-LAUR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAURELCO" b2="69 KV" b3="CB614" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAURELCO" b2="69 KV" b3="SW617" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIB_CHUR" b2="69 KV" b3="CB62C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LIB_CHUR" b2="69 KV" b3="LD_184" />
      <ContingencyEquipment Action="L" Type="LN" b1="BACONJ" b2="69 KV" b3="LIB-BACO" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARLEY2" b2="69 KV" b3="LIB-FARL" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LIB_CHUR" b2="69 KV" b3="SH_186" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEAVYJT2" b2="69 KV" b3="KEA-SCO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="S_CORBIN" b2="69 KV" b3="LD_185" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86600</SeqNum>
    <Name>230/115.Hunterstown.TR2</Name>
    <LastEdit Timestamp="2024-08-21T13:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="115 KV" b3="4B92" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="230 KV" b3="B126" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUNTERST" b2="230 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86630</SeqNum>
    <Name>L69.Kenton-Murphysville (Tie)</Name>
    <LastEdit Timestamp="2025-01-15T18:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTN_LG" b2="69 KV" b3="B091_604" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTN_LG" b2="69 KV" b3="B091_607" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KENTN_LG" b2="69 KV" b3="LD_1820" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENTN_LG" b2="69 KV" b3="MUR-KENT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MURPHYSV" b2="69 KV" b3="CBN4_634" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86640</SeqNum>
    <Name>L69.Lebanon-Springfield-NSpringfield (Tie)</Name>
    <LastEdit Timestamp="2025-07-25T16:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LEBANON3" b2="69 KV" b3="B043_607" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEBANON3" b2="69 KV" b3="B043_614" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEBANON3" b2="69 KV" b3="SPR-LEBA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="N_SPRFLD" b2="69 KV" b3="CBW3_627" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_SPRFLD" b2="69 KV" b3="CBW3_644" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRINGFI" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="N_SPRFLD" b2="69 KV" b3="NSP-SPRI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86650</SeqNum>
    <Name>230/115.Suffolk.TX1</Name>
    <LastEdit Timestamp="2024-11-04T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="230 KV" b3="H142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="115 KV" b3="L1T44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="115 KV" b3="L1TL5" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUFFOLK" b2="230 KV" b3="TX_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86660</SeqNum>
    <Name>L345.McLean-BrightStalk.94805 + BrightStalk.WF</Name>
    <LastEdit Timestamp="2025-01-30T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="92 MCLEA" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="92 MCLEA" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="92 MCLEA" b2="345 KV" b3="94805" />
      <ContingencyEquipment Action="U" Type="GEN" b1="948 BRIG" b2="34.5 KV" b3="BRSTLKWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="948 BRIG" b2="345 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="948 BRIG" b2="345 KV" b3="U1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86670</SeqNum>
    <Name>L345.Petersburg-Sullivan.Tie</Name>
    <LastEdit Timestamp="2024-08-21T15:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="7B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="7C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="345 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="345 KV" b3="J1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PETERSB2" b2="345 KV" b3="PET-SUL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86680</SeqNum>
    <Name>L138.Melmore-TiffinCenter</Name>
    <LastEdit Timestamp="2024-08-22T11:10:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MELMORE" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELMORE" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MELMORE" b2="138 KV" b3="MEL-TIF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFINCE" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFINCE" b2="138 KV" b3="F2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86690</SeqNum>
    <Name>L230.Beco-Pacific.2165</Name>
    <LastEdit Timestamp="2025-11-24T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BECO" b2="230 KV" b3="2165A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECO" b2="230 KV" b3="H12T2165" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECO" b2="230 KV" b3="H3T2165" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PACIFIC" b2="230 KV" b3="21652234" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PACIFIC" b2="230 KV" b3="216532" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86700</SeqNum>
    <Name>L69.Elizabethtown-TharpJct(Tie)</Name>
    <LastEdit Timestamp="2025-04-15T13:47:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZABET" b2="69 KV" b3="B034_614" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELIZABET" b2="69 KV" b3="B034_617" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIZABET" b2="69 KV" b3="ELI-THAR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="THARPJCT" b2="69 KV" b3="SW615" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86710</SeqNum>
    <Name>L69.Elizabethtown-Kargle(Tie)</Name>
    <LastEdit Timestamp="2025-04-15T13:47:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZABET" b2="69 KV" b3="B034_604" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELIZABET" b2="69 KV" b3="B034_607" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIZABET" b2="69 KV" b3="ELI-KARG" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KARGLE" b2="69 KV" b3="SW615" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86720</SeqNum>
    <Name>L69.EastBardstown-Bardstown(Tie)</Name>
    <LastEdit Timestamp="2024-08-22T11:16:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BARD_IND" b2="69 KV" b3="BAR-BRDT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BARD_IND" b2="69 KV" b3="BARDSTOW" />
      <ContingencyEquipment Action="L" Type="LN" b1="BARD_IND" b2="69 KV" b3="EBR-BARD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BARD_IND" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRDTW_LG" b2="69 KV" b3="B155_634" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRDTW_LG" b2="69 KV" b3="B155_637" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E_BARDST" b2="69 KV" b3="CBW4_614" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86730</SeqNum>
    <Name>L69.ClayVillageJunc(Tie)</Name>
    <LastEdit Timestamp="2025-01-31T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYVILL" b2="69 KV" b3="N19-614" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLAY_VIL" b2="69 KV" b3="B724-645" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYVILL" b2="69 KV" b3="CLA-CLA6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86740</SeqNum>
    <Name>L69.Stephensburg-Leitchfield(Tie)</Name>
    <LastEdit Timestamp="2024-08-22T15:31:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLARKSON" b2="69 KV" b3="CLA-WARR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLARKSON" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="E_VIEW" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="E_VIEW" b2="69 KV" b3="MID-EVI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEITCHFE" b2="69 KV" b3="B556_602" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEITCHFE" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEITCHFE" b2="69 KV" b3="LEI-LET" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LEITCHFE" b2="69 KV" b3="SH_1821" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEITCHFI" b2="69 KV" b3="B168_624" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEITCHFI" b2="69 KV" b3="B168_627" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEITCHFL" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEITCHFI" b2="69 KV" b3="LEI-LEIT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MID_V_CL" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLARKSON" b2="69 KV" b3="MID-CLAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEPHNSB" b2="69 KV" b3="CB634" />
      <ContingencyEquipment Action="L" Type="LN" b1="E_VIEW" b2="69 KV" b3="STE-EVI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STEPHNSB" b2="69 KV" b3="SW637" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WARREN_R" b2="69 KV" b3="LD_184" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEITCHFE" b2="69 KV" b3="LEI-WARR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86750</SeqNum>
    <Name>L69.Wofford-Goldbug(Tie)</Name>
    <LastEdit Timestamp="2025-03-24T11:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GOLDBUG" b2="69 KV" b3="S64-615" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOFFORD" b2="69 KV" b3="B002_604" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOFFORD" b2="69 KV" b3="B002_607" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOLDBUG" b2="69 KV" b3="WOF-GOLD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86770</SeqNum>
    <Name>L69.Bracknco-Carntown(Tie)</Name>
    <LastEdit Timestamp="2024-08-22T11:15:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRACKNCO" b2="69 KV" b3="BN45_624" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRACKNCO" b2="69 KV" b3="BN45_627" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRACKNCO" b2="69 KV" b3="BRA-CRNT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRNTN_LG" b2="69 KV" b3="B223_605" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86780</SeqNum>
    <Name>L69.BondsMill-SAnders1(Tie)</Name>
    <LastEdit Timestamp="2024-08-22T11:14:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BONDS_MI" b2="69 KV" b3="BON-SAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BONDS_MI" b2="69 KV" b3="N68-634" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BONDS_MI" b2="69 KV" b3="N69-637" />
      <ContingencyEquipment Action="OP" Type="CB" b1="S_ANDRSN" b2="69 KV" b3="W127-634" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="S_ANDRSN" b2="69 KV" b3="W127-637" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86790</SeqNum>
    <Name>L69.BondsMill-SAnders2(Tie)</Name>
    <LastEdit Timestamp="2024-08-22T11:15:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BONDS_MI" b2="69 KV" b3="BON-SAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BONDS_MI" b2="69 KV" b3="N69-644" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BONDS_MI" b2="69 KV" b3="N69-647" />
      <ContingencyEquipment Action="OP" Type="CB" b1="S_ANDRSN" b2="69 KV" b3="W127-624" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86830</SeqNum>
    <Name>L500.Brambleton-WishingStar.589</Name>
    <LastEdit Timestamp="2026-05-18T09:02:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="500 KV" b3="558T589" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRAMBLET" b2="500 KV" b3="BRA-WIS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="500 KV" b3="H2T589" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WISHSTAR" b2="500 KV" b3="58942-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WISHSTAR" b2="500 KV" b3="58942-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86850</SeqNum>
    <Name>L230.Swamp-Winfall.2144</Name>
    <LastEdit Timestamp="2026-05-11T11:37:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SWAMP" b2="230 KV" b3="2144" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWAMP" b2="230 KV" b3="214492" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWAMP" b2="230 KV" b3="247T2144" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINFALL" b2="230 KV" b3="20202144" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINFALL" b2="230 KV" b3="214422CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86860</SeqNum>
    <Name>L230.Swamp-Sunbury-Suffolk.247</Name>
    <LastEdit Timestamp="2024-08-22T14:45:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="230 KV" b3="246T247" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="230 KV" b3="24742" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUNBURY4" b2="230 KV" b3="247B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY4" b2="230 KV" b3="H132" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUNBURY4" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNBURY4" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWAMP" b2="230 KV" b3="24792" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUNBURY4" b2="230 KV" b3="247C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWAMP" b2="230 KV" b3="247T2144" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86880</SeqNum>
    <Name>L230.PleasantView-Belmont.2180</Name>
    <LastEdit Timestamp="2024-08-30T09:57:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLMNTDOM" b2="230 KV" b3="2180" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLMNTDOM" b2="230 KV" b3="21802286" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLMNTDOM" b2="230 KV" b3="21802311" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="230 KV" b3="20982180" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="230 KV" b3="H422" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEASNTV" b2="230 KV" b3="L3T2180" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLEASNTV" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLEASNTV" b2="35 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86890</SeqNum>
    <Name>L69.NorthLondon-NLondon(Tie)</Name>
    <LastEdit Timestamp="2024-08-22T15:00:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="N_LND104" b2="69 KV" b3="CB55_608" />
      <ContingencyEquipment Action="L" Type="LN" b1="N_LND104" b2="69 KV" b3="NLN-NLON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_LONDON" b2="69 KV" b3="PCB604" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_LONDON" b2="69 KV" b3="PCB614" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N_LONDON" b2="69 KV" b3="PCB644" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86900</SeqNum>
    <Name>L69.Renaker-Cynthiana-OxfordeK-Newtown2 (tie)</Name>
    <LastEdit Timestamp="2025-01-21T13:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CYNTHASW" b2="69 KV" b3="B144_615" />
      <ContingencyEquipment Action="L" Type="LN" b1="CYNTHASW" b2="69 KV" b3="CYN-OXFR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CYNTHASW" b2="69 KV" b3="KAW-CYT" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWTOWN2" b2="69 KV" b3="OXFR-NEW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NEWTOWN2" b2="69 KV" b3="SW605" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OXFRDEK" b2="69 KV" b3="LD_183" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RENAKER" b2="69 KV" b3="CBN6_664" />
      <ContingencyEquipment Action="L" Type="LN" b1="CYNTHASW" b2="69 KV" b3="REN-CYNT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86910</SeqNum>
    <Name>L69.Rogersville-VineGrove(Tie)</Name>
    <LastEdit Timestamp="2024-08-22T15:48:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PATR_PKW" b2="69 KV" b3="CB634" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PATR_PKW" b2="69 KV" b3="SW637" />
      <ContingencyEquipment Action="L" Type="LN" b1="RADCLIFF" b2="69 KV" b3="RAD-VNE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RADCLIFF" b2="69 KV" b3="RADCLIFF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RADCLIFF" b2="69 KV" b3="TBROWN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RADCLIFK" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="RADCLIFK" b2="69 KV" b3="RAD-VINE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROGERSKU" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="RADCLIFK" b2="69 KV" b3="RAD-ROGE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROGERSVI" b2="69 KV" b3="B160_634" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROGERSVI" b2="69 KV" b3="B160_637" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROGERSKU" b2="69 KV" b3="ROG-ROG2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PATR_PKW" b2="69 KV" b3="PAT-ROGR" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROGERSVI" b2="69 KV" b3="ROG-ROGE" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROGERSVJ" b2="69 KV" b3="ROG-VINE" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROGERSVJ" b2="69 KV" b3="ROG-SBOU" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SBOUNDRY" b2="69 KV" b3="SW615" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VINEGROV" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="RADCLIFF" b2="69 KV" b3="RAD-VIN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VNEGROVE" b2="69 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86920</SeqNum>
    <Name>L69.RussellCo-Union (tie)</Name>
    <LastEdit Timestamp="2025-01-02T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSELCO" b2="69 KV" b3="BS55_614" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUSSELCO" b2="69 KV" b3="RUSS-SEW" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SEWELLTN" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEWELLTN" b2="69 KV" b3="SEW-UNIO" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SEWELLTN" b2="69 KV" b3="SH_186" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="UNION_UN" b2="69 KV" b3="B642_605" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86930</SeqNum>
    <Name>L69.ScottCo-Penn2-Leeslick-Renaker (tie)</Name>
    <LastEdit Timestamp="2025-08-11T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KEITH2" b2="69 KV" b3="KEI-PEN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEITH2" b2="69 KV" b3="N38-605" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEESLICK" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEESLICK" b2="69 KV" b3="LEE-PENN" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEESLICK" b2="69 KV" b3="LEE-RENA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENN2" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENN2" b2="69 KV" b3="SCO-PENN" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PENN2" b2="69 KV" b3="SH_186" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RENAKER" b2="69 KV" b3="CB614" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOTT_CO" b2="69 KV" b3="B145_614" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86940</SeqNum>
    <Name>L69.BeattyvilleEKPC-BeattyvilleLGEE.Tie</Name>
    <LastEdit Timestamp="2024-11-20T16:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEATTYVL" b2="69 KV" b3="BTT-BEAT" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BTTYVEKP" b2="69 KV" b3="DUM1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86950</SeqNum>
    <Name>L230.Sewaren-Woodbridge-Layfayette-Metuchen.W-2328</Name>
    <LastEdit Timestamp="2024-08-22T14:54:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAFA PS" b2="230 KV" b3="LAF-WOO2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAFA PS" b2="230 KV" b3="T20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAFA PS" b2="230 KV" b3="LAF-MET2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEWAREN" b2="230 KV" b3="SEW-WOO2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODBRID" b2="230 KV" b3="T2LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>86970</SeqNum>
    <Name>L138.Edgemont-FallingBranch</Name>
    <LastEdit Timestamp="2024-08-22T14:56:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMONT" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEMONT" b2="138 KV" b3="EDG-FAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FALLINGB" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87000</SeqNum>
    <Name>L138.Edgemont-Vicker-Merrimac</Name>
    <LastEdit Timestamp="2024-08-22T14:54:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEMONT" b2="138 KV" b3="EDG-VIC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMONT" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERRIMAC" b2="138 KV" b3="MER-VIC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERRIMAC" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERRIMAC" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VICKER" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87010</SeqNum>
    <Name>L500.BurchesHill-Cheltenham.5071</Name>
    <LastEdit Timestamp="2025-08-29T13:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="500 KV" b3="14B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURCHESH" b2="500 KV" b3="14C" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURCHESH" b2="500 KV" b3="BUR-CHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHELTENH" b2="500 KV" b3="1AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHELTENH" b2="500 KV" b3="1BB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87020</SeqNum>
    <Name>765/345.Baker.T300</Name>
    <LastEdit Timestamp="2024-10-31T08:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BAKER" b2="765 KV" b3=".300" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="345 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="345 KV" b3="E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="765 KV" b3="N1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87030</SeqNum>
    <Name>345/138.JugStreet.XF5</Name>
    <LastEdit Timestamp="2025-09-24T08:43:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="X" Type="XF" b1="JUGSTRET" b2="345 KV" b3="XF5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87060</SeqNum>
    <Name>230/115.SedgeHill.TX1</Name>
    <LastEdit Timestamp="2024-08-22T10:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="230 KV" b3="H102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="115 KV" b3="L102" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEDGEHIL" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87070</SeqNum>
    <Name>230/115.SedgeHill.TX2</Name>
    <LastEdit Timestamp="2024-08-22T10:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="230 KV" b3="H202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="115 KV" b3="L202" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEDGEHIL" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87080</SeqNum>
    <Name>L115.Oakgreen-Mitchell-MountainRun.2</Name>
    <LastEdit Timestamp="2024-08-22T14:59:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MITCHLDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MITCHLDP" b2="115 KV" b3="2C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTN RUN" b2="115 KV" b3="2T70" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTN RUN" b2="115 KV" b3="RECLOAD3" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKGREEN" b2="115 KV" b3="2A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGREEN" b2="115 KV" b3="2T11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGREEN" b2="115 KV" b3="2T153" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87120</SeqNum>
    <Name>230/138.Waneeta.TR7</Name>
    <LastEdit Timestamp="2024-08-22T10:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WANEETA" b2="230 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="230 KV" b3="75" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WANEETA" b2="138 KV" b3="775" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87150</SeqNum>
    <Name>L230.Hudson-Kearny.G-2312</Name>
    <LastEdit Timestamp="2025-08-01T13:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="3-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUDSON" b2="230 KV" b3="HUD-KEAG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87160</SeqNum>
    <Name>L230.Hudson-Kearny.F-2311</Name>
    <LastEdit Timestamp="2025-08-01T13:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="4-12" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUDSON" b2="230 KV" b3="HUD-KEAF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87190</SeqNum>
    <Name>L230.Bergen-Saddlebrook.C-2334</Name>
    <LastEdit Timestamp="2025-09-16T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERGEN" b2="230 KV" b3="BER-SADC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SADDLEBR" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SADDLEBR" b2="230 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87200</SeqNum>
    <Name>L345.Bergen-Marion.E-3405</Name>
    <LastEdit Timestamp="2025-09-16T14:23:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="345 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERGEN" b2="345 KV" b3="BER-MAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION" b2="345 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION" b2="345 KV" b3="7-8" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MARION" b2="345 KV" b3="REACTOR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87210</SeqNum>
    <Name>L345.Bergen-Marion.F-3406</Name>
    <LastEdit Timestamp="2025-09-16T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="345 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERGEN" b2="345 KV" b3="BER-MAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION" b2="345 KV" b3="1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION" b2="345 KV" b3="9-10" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MARION" b2="345 KV" b3="REACTOR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87220</SeqNum>
    <Name>L230.Deans-MeadowRoad-PiersonAve-Metchuen.S-2219</Name>
    <LastEdit Timestamp="2025-04-08T10:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DEANS" b2="230 KV" b3="DEA-MEA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="230 KV" b3="SECT1-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="230 KV" b3="SECT2-11" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADOWRD" b2="230 KV" b3="MEA-PIE1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEADOWRD" b2="230 KV" b3="SUMMITSP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MEADOWRD" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWRD" b2="230 KV" b3="TRAN1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="METUCHEN" b2="230 KV" b3="MET-PIE" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PIERSOAV" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PIERSOAV" b2="230 KV" b3="TRAN T-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87250</SeqNum>
    <Name>L230.Essex-KearnySub-Kearny.L-2317</Name>
    <LastEdit Timestamp="2024-09-19T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="1-9CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="9-10CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEARNYSB" b2="230 KV" b3="ESS-KSBL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEARNY" b2="230 KV" b3="KEA-KSBL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEARNYSB" b2="230 KV" b3="T-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNYSB" b2="230 KV" b3="T-10CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87310</SeqNum>
    <Name>L230.Earleys.L2171</Name>
    <LastEdit Timestamp="2025-01-09T14:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="217162" />
      <ContingencyEquipment Action="S" Type="SD" b1="EARLEYS" b2="230 KV" b3="2171A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="EARLEYCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="WT2171" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87320</SeqNum>
    <Name>L138.Lewis-Dorothy</Name>
    <LastEdit Timestamp="2024-08-22T10:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DOROTHY" b2="138 KV" b3="DOR-LEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOROTHY" b2="138 KV" b3="P CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOROTHY" b2="138 KV" b3="Q CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="138 KV" b3="OCB O" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87350</SeqNum>
    <Name>Hoytdale.SVC</Name>
    <LastEdit Timestamp="2025-02-20T14:56:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="HOYTDAL2" b2="138 KV" b3="SVC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="138 KV" b3="SVCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87380</SeqNum>
    <Name>L230.KelsonRidge-Talbert-OakGrove.23184/23066</Name>
    <LastEdit Timestamp="2025-03-05T16:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSONRI" b2="230 KV" b3="2C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSONRI" b2="230 KV" b3="2D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="10AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGROVE" b2="230 KV" b3="10CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="KELSONRI" b2="230 KV" b3="KEL-TAL4" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKGROVE" b2="230 KV" b3="OAK-TAL6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87390</SeqNum>
    <Name>L230.KelsonRidge-Morgantown.23086</Name>
    <LastEdit Timestamp="2025-02-28T12:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSONRI" b2="230 KV" b3="1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSONRI" b2="230 KV" b3="1B" />
      <ContingencyEquipment Action="L" Type="LN" b1="KELSONRI" b2="230 KV" b3="KEL-MOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="8BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="8CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87400</SeqNum>
    <Name>L138.Mayfield-PawneeTap-Pawnee-LeroyCenter.Q1</Name>
    <LastEdit Timestamp="2025-02-10T13:37:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02PAWNEE" b2="138 KV" b3="SWR232" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02PAWNEE" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B79" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B80" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAYFLD" b2="138 KV" b3="04M-PAW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B19" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAWNEETP" b2="138 KV" b3="PAW-02P1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAWNEETP" b2="138 KV" b3="PAW-LER1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87410</SeqNum>
    <Name>345/138.Carson.T1</Name>
    <LastEdit Timestamp="2024-08-22T10:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CARS DUQ" b2="345 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARS DUQ" b2="138 KV" b3="T1LO CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARS DUQ" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87420</SeqNum>
    <Name>L138.Auburn-CountyLine-RobisonPark</Name>
    <LastEdit Timestamp="2024-08-22T14:56:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AUBURN" b2="138 KV" b3="AUB-COU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUBURN" b2="138 KV" b3="M CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="COUNTYIM" b2="138 KV" b3="COU-ROB1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COUNTYIM" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="F4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87430</SeqNum>
    <Name>L345.Kammer-WestBellaire</Name>
    <LastEdit Timestamp="2025-12-29T10:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="345 KV" b3="DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="345 KV" b3="DD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KAMMER2" b2="345 KV" b3="KAM-WBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="345 KV" b3="M2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87440</SeqNum>
    <Name>L345.WestBellaire-Tidd</Name>
    <LastEdit Timestamp="2024-08-22T10:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="BB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="345 KV" b3="M1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TIDD_AEP" b2="345 KV" b3="TID-WBE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87470</SeqNum>
    <Name>230/138.Emilie.T9</Name>
    <LastEdit Timestamp="2024-08-27T09:39:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="138 KV" b3="395" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="230 KV" b3="995" />
      <ContingencyEquipment Action="X" Type="XF" b1="EMILIE" b2="230 KV" b3="TR9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87480</SeqNum>
    <Name>L138.Keemin-18706-187SchauffRoad.18706</Name>
    <LastEdit Timestamp="2025-11-11T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="125 NORM" b2="138 KV" b3="TR79 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="187 SCHA" b2="138 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="187 SCHA" b2="138 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="18706" b2="138 KV" b3="18706_1" />
      <ContingencyEquipment Action="L" Type="LN" b1="18706" b2="138 KV" b3="18706_2" />
      <ContingencyEquipment Action="L" Type="LN" b1="125 NORM" b2="138 KV" b3="18706_Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEEMIN" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEEMIN" b2="138 KV" b3="H11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87490</SeqNum>
    <Name>345/138.Tidd.T-B</Name>
    <LastEdit Timestamp="2024-12-12T13:45:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TIDD_AEP" b2="345 KV" b3="B-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="TIDD_AEP" b2="138 KV" b3="B-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="GG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="GG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="M1" />
      <ContingencyEquipment Action="S" Type="SD" b1="TIDD_AEP" b2="138 KV" b3="REAC2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87500</SeqNum>
    <Name>Covert.GTG2 &amp; STG2</Name>
    <LastEdit Timestamp="2024-08-22T15:04:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="345 KV" b3="1020" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COVERT" b2="16 KV" b3="2GTG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="16 KV" b3="2GTG CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COVERT" b2="16 KV" b3="2STG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="16 KV" b3="2STG CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="345 KV" b3="3040" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COVERT" b2="16 KV" b3="SS2 LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="COVERT" b2="345 KV" b3="TB2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87510</SeqNum>
    <Name>Covert.GTG3 &amp; STG3</Name>
    <LastEdit Timestamp="2024-08-22T15:05:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="345 KV" b3="3040" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COVERT" b2="16 KV" b3="3GTG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="16 KV" b3="3GTG CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COVERT" b2="16 KV" b3="3STG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="16 KV" b3="3STG CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="345 KV" b3="4050" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COVERT" b2="16 KV" b3="SS3 LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="COVERT" b2="345 KV" b3="TB3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87530</SeqNum>
    <Name>L138.Jefferson-Grand.4525 G SPOG 2-46</Name>
    <LastEdit Timestamp="2024-08-23T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="45 JEFFE" b2="138 KV" b3="4525" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT4-5 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87540</SeqNum>
    <Name>L138.Jefferson-Grand.4527 G SPOG 2-46</Name>
    <LastEdit Timestamp="2024-08-23T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="45 JEFFE" b2="138 KV" b3="4527" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT5-6 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87550</SeqNum>
    <Name>L138.Grand-Crosby.5825 G SPOG 2-46</Name>
    <LastEdit Timestamp="2024-08-23T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="82 CROSB" b2="138 KV" b3="5825" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1516CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1617CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="82 CROSB" b2="138 KV" b3="I5825" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87560</SeqNum>
    <Name>L138.Grand-Crosby.5827 G SPOG 2-46</Name>
    <LastEdit Timestamp="2024-08-23T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="82 CROSB" b2="138 KV" b3="5827" />
      <ContingencyEquipment Action="CL" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="82 CROSB" b2="138 KV" b3="I5827" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87570</SeqNum>
    <Name>L138.LeroyCtr-PineGroveTap-Mayfield.Q4</Name>
    <LastEdit Timestamp="2025-04-07T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B85" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEROYCEN" b2="138 KV" b3="LER1-PIN" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAYFLD" b2="138 KV" b3="04M-PIN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAYFLD" b2="138 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEGROV" b2="138 KV" b3="CS432" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINEGROV" b2="138 KV" b3="PIN-PIN4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87580</SeqNum>
    <Name>765/500.Cloverdale.T14</Name>
    <LastEdit Timestamp="2025-05-30T14:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="765 KV" b3="BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="765 KV" b3="BB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="500 KV" b3="GG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="500 KV" b3="GG1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVERD2" b2="765 KV" b3="T14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87590</SeqNum>
    <Name>500/345.Cloverdale.T15</Name>
    <LastEdit Timestamp="2024-08-23T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="500 KV" b3="GG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="500 KV" b3="GG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="345 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="345 KV" b3="R2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVERD2" b2="500 KV" b3="T15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87600</SeqNum>
    <Name>500/345.Cloverdale.T16</Name>
    <LastEdit Timestamp="2024-08-23T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="500 KV" b3="FF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="500 KV" b3="FF2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="345 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="345 KV" b3="P2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVERD2" b2="500 KV" b3="T16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87610</SeqNum>
    <Name>138/69.Richland(AEP).T2</Name>
    <LastEdit Timestamp="2024-08-23T10:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="RICHLAND" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLAND" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLAND" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLAND" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87620</SeqNum>
    <Name>138/69.Richland(AEP).T3</Name>
    <LastEdit Timestamp="2024-08-23T10:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLAND" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLAND" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLAND" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="X" Type="XF" b1="RICHLAND" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87640</SeqNum>
    <Name>Tasley.CT10</Name>
    <LastEdit Timestamp="2024-08-27T09:45:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TASLEY" b2="12 KV" b3="450" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TASLEY" b2="69 KV" b3="7465" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TASLEY" b2="12 KV" b3="G10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TASLEY" b2="12 KV" b3="LOADSS" />
      <ContingencyEquipment Action="X" Type="XF" b1="TASLEY" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87690</SeqNum>
    <Name>L138.159Northbrook-15913-48Highland.15913</Name>
    <LastEdit Timestamp="2024-12-12T11:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="159 NORT" b2="138 KV" b3="L15913CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="48 HIGHL" b2="138 KV" b3="15913 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="15913" b2="138 KV" b3="15913 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="15913" b2="138 KV" b3="15913 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="15913" b2="138 KV" b3="15913 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="15913" b2="138 KV" b3="15913 5" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="212 NORT" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="212 NORT" b2="138 KV" b3="L15913CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="213 DEER" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="213 DEER" b2="138 KV" b3="L15913CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="48 HIGHL" b2="138 KV" b3="L15913" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87700</SeqNum>
    <Name>L138.Wickliffe-Riverbend</Name>
    <LastEdit Timestamp="2024-08-23T10:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RVERBDOE" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="RVERBDOE" b2="138 KV" b3="RVE-WIC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WICKLIFF" b2="138 KV" b3="B145" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WICKLIFF" b2="138 KV" b3="B146" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87710</SeqNum>
    <Name>138/26.Wickliffe.TR3</Name>
    <LastEdit Timestamp="2025-04-24T14:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WICKLIFF" b2="138 KV" b3="B103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WICKLIFF" b2="138 KV" b3="B145" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WICKLIFF" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87720</SeqNum>
    <Name>138/13.Brunswick.TR4&amp;TR5</Name>
    <LastEdit Timestamp="2024-08-23T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWOE" b2="138 KV" b3="B202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWOE" b2="138 KV" b3="B204" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNSWOE" b2="138 KV" b3="TR4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNSWOE" b2="138 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87730</SeqNum>
    <Name>345/138.Bergen.345-1 &amp; 345-3</Name>
    <LastEdit Timestamp="2025-09-16T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="138 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="345 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="345 KV" b3="3-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="345 KV" b3="345-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="345 KV" b3="345-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="138 KV" b3="4-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87740</SeqNum>
    <Name>345/230.Bergen.345-2 &amp; 345-4</Name>
    <LastEdit Timestamp="2025-09-18T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="345 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="21-22" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="345 KV" b3="345-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BERGEN" b2="345 KV" b3="345-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="6-22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87770</SeqNum>
    <Name>L138.Mottville-StubeyRoad</Name>
    <LastEdit Timestamp="2024-11-18T12:57:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTTVILL" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOTTVILL" b2="138 KV" b3="MOT-STUB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="138 KV" b3="M000Z8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="138 KV" b3="M001A5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87780</SeqNum>
    <Name>138/69.Campbell.T2</Name>
    <LastEdit Timestamp="2024-08-23T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CAMPOHED" b2="69 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPOHED" b2="69 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPOHED" b2="138 KV" b3="B73" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPOHED" b2="138 KV" b3="B90" />
      <ContingencyEquipment Action="X" Type="XF" b1="CAMPOHED" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87790</SeqNum>
    <Name>230/69.Dennis.T3</Name>
    <LastEdit Timestamp="2024-10-31T08:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="230 KV" b3="GCB E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="230 KV" b3="GCB G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="X" Type="XF" b1="DENNIS" b2="230 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87800</SeqNum>
    <Name>L69.Dennis-Tuckahoe</Name>
    <LastEdit Timestamp="2025-06-04T14:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DENNIS" b2="69 KV" b3="DEN-TUC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUCKAHOE" b2="69 KV" b3="GCB F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87820</SeqNum>
    <Name>L138.TiffinCenter-FremontCenter.1</Name>
    <LastEdit Timestamp="2024-10-25T13:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FREMONTC" b2="138 KV" b3="FRE-TIF1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONTC" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFINCE" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFINCE" b2="138 KV" b3="F1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87830</SeqNum>
    <Name>L230.Chichester-Post.220-39A</Name>
    <LastEdit Timestamp="2024-10-31T08:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICHEST" b2="230 KV" b3="395 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHICHEST" b2="230 KV" b3="CHI-POS" />
      <ContingencyEquipment Action="S" Type="SD" b1="CHICHEST" b2="230 KV" b3="L22039" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POST" b2="230 KV" b3="695" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POST" b2="230 KV" b3="895" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87850</SeqNum>
    <Name>L138.Brady-Darrow</Name>
    <LastEdit Timestamp="2025-08-13T13:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADYLAK" b2="138 KV" b3="B56" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADYLAK" b2="138 KV" b3="B68" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARROW" b2="138 KV" b3="DAR-BRA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARROW" b2="138 KV" b3="B113" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARROW" b2="138 KV" b3="B117" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87870</SeqNum>
    <Name>L345.Ramapo-SugarLoaf-RockTavern</Name>
    <LastEdit Timestamp="2024-08-27T09:44:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="76-1Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAMAPO" b2="345 KV" b3="76-2X" />
      <ContingencyEquipment Action="L" Type="LN" b1="RAMAPO" b2="345 KV" b3="RAM-SUG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKTAVE" b2="345 KV" b3="376512" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKTAVE" b2="345 KV" b3="376523" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKTAVE" b2="345 KV" b3="ROC-SUG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGRLOAF" b2="345 KV" b3="76-112-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87900</SeqNum>
    <Name>L115.Englishtown-Wyckoff</Name>
    <LastEdit Timestamp="2026-02-10T11:23:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="115 KV" b3="B160" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLISHT" b2="115 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENGLISHT" b2="115 KV" b3="ENG-WYCK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYCKOFF" b2="34.5 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYCKOFF" b2="34.5 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYCKOFF" b2="115 KV" b3="B4" />
      <ContingencyEquipment Action="X" Type="XF" b1="WYCKOFF" b2="115 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87910</SeqNum>
    <Name>L138.Kiamensi-Milltown.13834</Name>
    <LastEdit Timestamp="2025-05-16T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="141" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="142" />
      <ContingencyEquipment Action="L" Type="LN" b1="KIAMENSI" b2="138 KV" b3="KIA-MIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLTOWN" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLTOWN" b2="138 KV" b3="132" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87920</SeqNum>
    <Name>138thStreet.SVC</Name>
    <LastEdit Timestamp="2025-02-20T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ST138" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ST138" b2="138 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87930</SeqNum>
    <Name>L69.Corson-Dennis.0604</Name>
    <LastEdit Timestamp="2025-05-20T11:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CORSON" b2="69 KV" b3="COR-DEN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORSON" b2="69 KV" b3="OCB N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="69 KV" b3="K" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87950</SeqNum>
    <Name>L138.Babbitt-JugStreet</Name>
    <LastEdit Timestamp="2024-10-22T16:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BABBITT" b2="138 KV" b3="BAB-JUG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="138 KV" b3="BD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="138 KV" b3="BE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87960</SeqNum>
    <Name>L161.LaurelCo-Pittsburg(LGEE)-Tyner</Name>
    <LastEdit Timestamp="2024-08-27T09:42:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAURELCO" b2="161 KV" b3="CB1024" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAURELCO" b2="161 KV" b3="PIT-LAUR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAURELCO" b2="161 KV" b3="SW1027" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PITTSBUR" b2="161 KV" b3="B051_803" />
      <ContingencyEquipment Action="L" Type="LN" b1="PITTSBUR" b2="161 KV" b3="PIT-PITT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYNER" b2="161 KV" b3="CB1014" />
      <ContingencyEquipment Action="L" Type="LN" b1="PITTS_EK" b2="161 KV" b3="PIT-TYNE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TYNER" b2="161 KV" b3="SW1017" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>87970</SeqNum>
    <Name>L345.Stemple-Tidd</Name>
    <LastEdit Timestamp="2025-03-24T11:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STEMPLE" b2="345 KV" b3="M2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEMPLE" b2="345 KV" b3="N1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STEMPLE" b2="345 KV" b3="STE-TID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="345 KV" b3="AA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88010</SeqNum>
    <Name>138/69.Trenton.BK8</Name>
    <LastEdit Timestamp="2024-08-26T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TRENTON2" b2="138 KV" b3="BK-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON2" b2="69 KV" b3="CB609" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON2" b2="138 KV" b3="CB811" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88020</SeqNum>
    <Name>138/69.ShakerRun.BK1</Name>
    <LastEdit Timestamp="2024-08-26T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHKR_RUN" b2="138 KV" b3="822" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHKR_RUN" b2="138 KV" b3="824" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHKR_RUN" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHKR_RUN" b2="69 KV" b3="CB763" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHKR_RUN" b2="69 KV" b3="CB779" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88030</SeqNum>
    <Name>345/34.Cook.T9</Name>
    <LastEdit Timestamp="2024-08-26T15:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="34 KV" b3="BF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="34 KV" b3="BG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="J2" />
      <ContingencyEquipment Action="X" Type="XF" b1="COOK" b2="345 KV" b3="T9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88040</SeqNum>
    <Name>L138.WillCounty-1803-Romeoville.1803</Name>
    <LastEdit Timestamp="2025-10-06T11:44:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="18 WILL" b2="138 KV" b3="1803 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="18 WILL" b2="138 KV" b3="L1803 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="18 WILL" b2="138 KV" b3="L1803TBD" />
      <ContingencyEquipment Action="L" Type="LN" b1="1803" b2="138 KV" b3="1803 Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="1803" b2="138 KV" b3="1803-314" />
      <ContingencyEquipment Action="U" Type="GEN" b1="411 ROME" b2="138 KV" b3="MAGID_BS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="411 ROME" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88050</SeqNum>
    <Name>L345.RobisonPark-Sorenson</Name>
    <LastEdit Timestamp="2024-08-26T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="345 KV" b3="K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="345 KV" b3="KM" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROBISONP" b2="345 KV" b3="ROB-SOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="D1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88060</SeqNum>
    <Name>L230.SwinksMill-Tysons.2108</Name>
    <LastEdit Timestamp="2025-12-30T14:37:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SWINKMIL" b2="230 KV" b3="20292108" />
      <ContingencyEquipment Action="L" Type="LN" b1="SWINKMIL" b2="230 KV" b3="2108" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWINKMIL" b2="230 KV" b3="H142" />
      <ContingencyEquipment Action="X" Type="XF" b1="SWINKMIL" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWINKMIL" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYSONS" b2="230 KV" b3="20102108" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYSONS" b2="230 KV" b3="210832" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88090</SeqNum>
    <Name>138/69.FremontCenter.T1</Name>
    <LastEdit Timestamp="2024-08-26T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONTC" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="X" Type="XF" b1="FREMONTC" b2="138 KV" b3="T1 XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONTC" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88120</SeqNum>
    <Name>345/138.BiersRun.TX1</Name>
    <LastEdit Timestamp="2024-08-26T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="345 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BIERSRUN" b2="345 KV" b3="XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88140</SeqNum>
    <Name>L138.OliverPlow-Studebaker</Name>
    <LastEdit Timestamp="2024-08-26T15:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVERPL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUDEBAK" b2="138 KV" b3="AC" />
      <ContingencyEquipment Action="L" Type="LN" b1="OLIVERPL" b2="138 KV" b3="OLI-STU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88170</SeqNum>
    <Name>L138.Lisle-Woodridge-DownerGrove-10319-52517.10319</Name>
    <LastEdit Timestamp="2025-11-11T10:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="0907" b2="138 KV" b3="0720CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="103 LISL" b2="138 KV" b3="10319 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="138 KV" b3="L10319CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="0907" b2="138 KV" b3="0907_6" />
      <ContingencyEquipment Action="L" Type="LN" b1="10319" b2="138 KV" b3="10319 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="10319" b2="138 KV" b3="10319 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="10319" b2="138 KV" b3="10319 5" />
      <ContingencyEquipment Action="S" Type="SD" b1="10319" b2="138 KV" b3="10319 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="10319" b2="138 KV" b3="10319Z4" />
      <ContingencyEquipment Action="L" Type="LN" b1="10319" b2="138 KV" b3="10319Z5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="52517" b2="138 KV" b3="517-0319" />
      <ContingencyEquipment Action="L" Type="LN" b1="559 WOOD" b2="138 KV" b3="10319 4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="559 WOOD" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="580 DOWN" b2="138 KV" b3="10319CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="580 DOWN" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="W602" b2="138 KV" b3="BT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W602" b2="138 KV" b3="L10319CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="W603" b2="138 KV" b3="BT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W603" b2="138 KV" b3="L10319CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88200</SeqNum>
    <Name>L115.Jackson-Menges.994 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="115 KV" b3="B16" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACK ME" b2="115 KV" b3="JAC-MEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MENGES" b2="115 KV" b3="99466" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88210</SeqNum>
    <Name>L115.Menges-PHGlatfelter.994 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-05T10:02:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MENGES" b2="115 KV" b3="99469" />
      <ContingencyEquipment Action="L" Type="LN" b1="MENGES" b2="115 KV" b3="MEN-PHG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHGLATFE" b2="115 KV" b3="B99412" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88230</SeqNum>
    <Name>L138.Desoto-Mayfield-23rdStreetTap</Name>
    <LastEdit Timestamp="2024-11-15T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="23RDSTRE" b2="138 KV" b3="U" />
      <ContingencyEquipment Action="L" Type="LN" b1="DESOTO" b2="138 KV" b3="DES-MAY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="L" Type="LN" b1="23RDSTRE" b2="138 KV" b3="23R-MAY" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAYFIELD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88640</SeqNum>
    <Name>138/69/34.ValleyIM.T1</Name>
    <LastEdit Timestamp="2025-04-24T14:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="VALLEYIM" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="VALLEYIM" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="VALLEYIM" b2="34 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEYIM" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMERON" b2="69 KV" b3="CAM-VALL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VALLEYIM" b2="34 KV" b3="GLENWTAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEYIM" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88720</SeqNum>
    <Name>345/34.MeadowLake.T1 + MeadowLake.WF1</Name>
    <LastEdit Timestamp="2025-05-05T13:17:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWLK" b2="345 KV" b3="BT1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWLK" b2="345 KV" b3="BT2-3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MEADOWLK" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MEADOWLK" b2="34.5 KV" b3="CAP2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEADOWLK" b2="34.5 KV" b3="MEDWLKWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEADOWLK" b2="345 KV" b3="T-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88730</SeqNum>
    <Name>345/34.MeadowLake.T1-GSU + MeadowLake.WF2&amp;3</Name>
    <LastEdit Timestamp="2025-05-05T13:17:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWLK" b2="345 KV" b3="BT1-2NEW" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEADOWLK" b2="34.5 KV" b3="MEDLK2WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEADOWLK" b2="34.5 KV" b3="MEDLK3WF" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEADOWLK" b2="345 KV" b3="T-1GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88740</SeqNum>
    <Name>L69.SummitAve-UpperSaddleRiver.654</Name>
    <LastEdit Timestamp="2025-06-23T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMITAV" b2="69 KV" b3="654-72-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="UPPERSAD" b2="69 KV" b3="654-49-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUMMITAV" b2="69 KV" b3="SUM-UPP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88750</SeqNum>
    <Name>L69.SummitAve-Montvale</Name>
    <LastEdit Timestamp="2024-08-26T16:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTVALE" b2="69 KV" b3="656-29-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMITAV" b2="69 KV" b3="656-72-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONTVALE" b2="69 KV" b3="MON-SUM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88760</SeqNum>
    <Name>138/69.Kammer.TX4</Name>
    <LastEdit Timestamp="2025-04-28T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="69 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="69 KV" b3="M6" />
      <ContingencyEquipment Action="X" Type="XF" b1="KAMMER2" b2="138 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88800</SeqNum>
    <Name>L115.TradeCity-Punxsutawney</Name>
    <LastEdit Timestamp="2025-06-19T10:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PUNXSUTA" b2="115 KV" b3="1 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRADECIT" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRADECIT" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="PUNXSUTA" b2="115 KV" b3="PUN-TRA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88810</SeqNum>
    <Name>L138.Celanese-NBlackburg</Name>
    <LastEdit Timestamp="2024-08-26T15:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CELANESE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="NBLACKSB" b2="138 KV" b3="NBL-CEL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBLACKSB" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88820</SeqNum>
    <Name>L138.NBlackburg-Kumis-MattFunk</Name>
    <LastEdit Timestamp="2024-08-26T15:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KUMIS" b2="138 KV" b3="KUM-MAT1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KUMIS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="J1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KUMIS" b2="138 KV" b3="KUM-NBL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBLACKSB" b2="138 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88830</SeqNum>
    <Name>L138.Holloway-Nottingham.1</Name>
    <LastEdit Timestamp="2024-08-26T15:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="F3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="F4" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLLOWAY" b2="138 KV" b3="HOL-NOT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="N8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88840</SeqNum>
    <Name>L138.Nottingham-NewStacy-PoloTap-Washington-Knox</Name>
    <LastEdit Timestamp="2024-08-26T15:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOX" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KNOX" b2="138 KV" b3="B80" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWSTACY" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWSTACY" b2="138 KV" b3="NEW-NOT" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWSTACY" b2="138 KV" b3="NEW-POL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="N7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POLO" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POLO" b2="138 KV" b3="POLO_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="POLO" b2="138 KV" b3="POL-POL" />
      <ContingencyEquipment Action="L" Type="LN" b1="POLOTAP" b2="138 KV" b3="POL-WAS" />
      <ContingencyEquipment Action="L" Type="LN" b1="KNOX" b2="138 KV" b3="KNO-WAS1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WASHINTN" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88850</SeqNum>
    <Name>L115.Nasa-Peninsula.2</Name>
    <LastEdit Timestamp="2024-10-31T08:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="NASADOM" b2="115 KV" b3="DUM" />
      <ContingencyEquipment Action="L" Type="LN" b1="NASADOM" b2="115 KV" b3="PEN-NAS2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NASADOM" b2="22 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="NASADOM" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENINSLA" b2="115 KV" b3="T22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88870</SeqNum>
    <Name>L230.Conastone-Graceton.2324</Name>
    <LastEdit Timestamp="2025-08-26T17:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="2324_GCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASTON" b2="230 KV" b3="3TR_2324" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONASTON" b2="230 KV" b3="CON-GRAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRACETON" b2="230 KV" b3="2324-1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRACETON" b2="230 KV" b3="2324-2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88880</SeqNum>
    <Name>L138.Amos-Ortin-Chemical</Name>
    <LastEdit Timestamp="2024-08-26T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="138 KV" b3="AMO-ORT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="138 KV" b3="AB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHEMICAL" b2="138 KV" b3="CHE-ORT1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ORTIN" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88890</SeqNum>
    <Name>L500.Hosensack-Lauschtown.5066</Name>
    <LastEdit Timestamp="2025-06-04T14:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="500 KV" b3="ELROLAUS" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOSENSAC" b2="500 KV" b3="HOS-LAU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSAC" b2="500 KV" b3="LAUS_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="500 KV" b3="HOSEN_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="500 KV" b3="HOSEN_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88900</SeqNum>
    <Name>500/230.Lauschtown.T3</Name>
    <LastEdit Timestamp="2024-08-26T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LAUSCHTO" b2="500 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="500 KV" b3="TRAN3_H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="230 KV" b3="TRAN3_L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88910</SeqNum>
    <Name>L500.Lackawanna-Shickshinny.5062</Name>
    <LastEdit Timestamp="2025-03-28T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LACKAWAN" b2="500 KV" b3="LAC-SHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="500 KV" b3="SHICEAST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="500 KV" b3="SHICWEST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHICKSHI" b2="500 KV" b3="LACK E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHICKSHI" b2="500 KV" b3="LACK W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88920</SeqNum>
    <Name>230/115.HighRidge.230-1</Name>
    <LastEdit Timestamp="2025-06-06T12:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HIGHRIDG" b2="230 KV" b3="230-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="230-1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="115 KV" b3="230-1LS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="23012316" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HIGHRIDG" b2="115 KV" b3="6-7TIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88930</SeqNum>
    <Name>230/115.HighRidge.230-2</Name>
    <LastEdit Timestamp="2025-06-06T12:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HIGHRIDG" b2="230 KV" b3="230-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="230-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="115 KV" b3="230-2LS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="230 KV" b3="23342302" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HIGHRIDG" b2="115 KV" b3="6-7TIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88940</SeqNum>
    <Name>230/69.Lyons.BK5</Name>
    <LastEdit Timestamp="2024-08-30T12:12:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LYONS" b2="230 KV" b3="103172" />
      <ContingencyEquipment Action="X" Type="XF" b1="LYONS" b2="230 KV" b3="5 BK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYONS" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYONS" b2="69 KV" b3="B6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88950</SeqNum>
    <Name>L345.Bayway-Linden.W-3423</Name>
    <LastEdit Timestamp="2025-06-03T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYWAY" b2="345 KV" b3="BAY-LIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="345 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88960</SeqNum>
    <Name>L345.Bayway-Linden.Z-3452</Name>
    <LastEdit Timestamp="2025-04-08T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="4-12" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYWAY" b2="345 KV" b3="BAY-LIN3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="345 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="345 KV" b3="7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88970</SeqNum>
    <Name>L345.Bayway-Linden.T-3446</Name>
    <LastEdit Timestamp="2025-06-03T09:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="4-14" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYWAY" b2="345 KV" b3="BAY-LIN4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="345 KV" b3="1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="345 KV" b3="9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>88980</SeqNum>
    <Name>L138.Holloway-Nottingham.2</Name>
    <LastEdit Timestamp="2024-08-26T15:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="E3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="E4" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLLOWAY" b2="138 KV" b3="HOL-NOT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="M6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89000</SeqNum>
    <Name>115/46.Claysburg.T2</Name>
    <LastEdit Timestamp="2024-11-21T14:34:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSBUR" b2="46 KV" b3="B29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSBUR" b2="115 KV" b3="B47" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSBUR" b2="115 KV" b3="B48" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLAYSBUR" b2="115 KV" b3="NO.2-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89030</SeqNum>
    <Name>L138.Harmon-Yager</Name>
    <LastEdit Timestamp="2024-08-27T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARMONOE" b2="138 KV" b3="HAR-YAG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89040</SeqNum>
    <Name>L138.Cloverdale-Yager</Name>
    <LastEdit Timestamp="2025-11-17T16:10:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVEROE" b2="138 KV" b3="B112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVEROE" b2="138 KV" b3="CLO-YAG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89050</SeqNum>
    <Name>L138.Stinger-ValleyIM</Name>
    <LastEdit Timestamp="2025-05-15T09:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STINGER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="STINGER" b2="138 KV" b3="STI-VAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEYIM" b2="138 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89060</SeqNum>
    <Name>L138.Brody-Stinger</Name>
    <LastEdit Timestamp="2024-11-20T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRODY" b2="138 KV" b3="BRO-FLO" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRODY" b2="138 KV" b3="BRO-STI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRODY" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRODY" b2="138 KV" b3="MIDWEST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STINGER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="STINGER" b2="138 KV" b3="STI-VAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STINGER" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89070</SeqNum>
    <Name>L115.ChaseCity-BarnJ-DryB-MtLaur-Claysmil.33</Name>
    <LastEdit Timestamp="2026-04-23T08:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BARNJNDP" b2="115 KV" b3="BAR-CHAS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BARNJNDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHASECTY" b2="115 KV" b3="3312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSMIL" b2="115 KV" b3="3362" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSMIL" b2="115 KV" b3="33T1039" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYSMIL" b2="115 KV" b3="CLA-MTLA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DRYBURG" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DRYBURG" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BARNJNDP" b2="115 KV" b3="33B" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTLAURE4" b2="115 KV" b3="33BC" />
      <ContingencyEquipment Action="X" Type="XF" b1="MTLAURE4" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTLAURE4" b2="13 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89090</SeqNum>
    <Name>L115.Highpoint-Rockwood</Name>
    <LastEdit Timestamp="2024-08-27T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHPNT" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHPNT" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHPNT" b2="115 KV" b3="HIG-ROC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKWOOD" b2="115 KV" b3="B36" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89100</SeqNum>
    <Name>L138.Yager-Nottingham.1</Name>
    <LastEdit Timestamp="2024-08-27T15:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="M5" />
      <ContingencyEquipment Action="L" Type="LN" b1="NOTINGHA" b2="138 KV" b3="NOT-YAG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="138 KV" b3="E2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89130</SeqNum>
    <Name>Joffre.SVC</Name>
    <LastEdit Timestamp="2025-11-21T12:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOFFRE" b2="138 KV" b3="10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JOFFRE" b2="138 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89140</SeqNum>
    <Name>L138.RichwoodHill-Mobley</Name>
    <LastEdit Timestamp="2025-06-24T13:07:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MOBLEY" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOBLEY" b2="138 KV" b3="MOB-RIC" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RICHWDHL" b2="138 KV" b3="A1051" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHWDHL" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHWDHL" b2="138 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89160</SeqNum>
    <Name>L138.Britton-Davidson.2</Name>
    <LastEdit Timestamp="2024-08-27T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRITTON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRITTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIDSON" b2="138 KV" b3="AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIDSON" b2="138 KV" b3="B CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRITTON" b2="138 KV" b3="BRI-DAV2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89170</SeqNum>
    <Name>L138.Brody-FlowerFieldRoad-MoorePark</Name>
    <LastEdit Timestamp="2024-08-27T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRODY" b2="138 KV" b3="BRO-FLO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRODY" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLOWRFLD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLOWRFLD" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLOWRFLD" b2="138 KV" b3="FLO-MOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOOREPAR" b2="138 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89180</SeqNum>
    <Name>L138.Hydramatic-MoorePark</Name>
    <LastEdit Timestamp="2024-08-27T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HYDRAMAT" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HYDRAMAT" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOOREPAR" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="L" Type="LN" b1="HYDRAMAT" b2="138 KV" b3="HYD-MOO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89200</SeqNum>
    <Name>L765.HangingRock-NorthProctorville</Name>
    <LastEdit Timestamp="2024-10-18T13:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANGING2" b2="765 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANGING2" b2="765 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="765 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="765 KV" b3="K1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NPROCTO2" b2="765 KV" b3="NPR-HAN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89210</SeqNum>
    <Name>765/138.NorthProctorville.T2</Name>
    <LastEdit Timestamp="2026-01-02T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="765 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="765 KV" b3="J1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NPROCTO2" b2="765 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89220</SeqNum>
    <Name>L765.Amos-NorthProctorville</Name>
    <LastEdit Timestamp="2024-10-18T13:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="765 KV" b3="AMO-NPR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="RB1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="AMOS" b2="765 KV" b3="RXFA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="AMOS" b2="765 KV" b3="RXFB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="AMOS" b2="765 KV" b3="RXFC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="765 KV" b3="U2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="765 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="765 KV" b3="J2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89230</SeqNum>
    <Name>L230.Clark-SunsetHill-DavisDrive.2033</Name>
    <LastEdit Timestamp="2025-01-27T15:17:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARK4" b2="230 KV" b3="2005T203" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARK4" b2="230 KV" b3="202T2033" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLARK4" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLARK4" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISDRV" b2="230 KV" b3="H12T2033" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISDRV" b2="230 KV" b3="H34T2033" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAVISDRV" b2="230 KV" b3="2033" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLARK4" b2="230 KV" b3="2033B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNSETHL" b2="34.5 KV" b3="LOAD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SUNSETHL" b2="34.5 KV" b3="SC1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SUNSETHL" b2="34.5 KV" b3="SC2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUNSETHL" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89260</SeqNum>
    <Name>L138.Holloway-Nottingham.5</Name>
    <LastEdit Timestamp="2024-08-27T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLLOWAY" b2="138 KV" b3="HOL-NOT5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="J6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89270</SeqNum>
    <Name>L138.Holloway-Nottingham.3</Name>
    <LastEdit Timestamp="2024-08-27T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLLOWAY" b2="138 KV" b3="HOL-NOT3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="L6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89280</SeqNum>
    <Name>L69.Adena-Ross</Name>
    <LastEdit Timestamp="2024-08-30T12:26:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADENA" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="ADENA" b2="69 KV" b3="ADE-ROS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ADENA" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADENA" b2="69 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="69 KV" b3="F2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="69 KV" b3="G1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89300</SeqNum>
    <Name>230/69.NorthLebanon.T1</Name>
    <LastEdit Timestamp="2024-08-27T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NLEBNON" b2="230 KV" b3="1BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEBNON" b2="230 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEBNON" b2="230 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEBNON" b2="69 KV" b3="B27" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89310</SeqNum>
    <Name>230/69.Northkill.T1</Name>
    <LastEdit Timestamp="2024-08-27T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHKILL" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHKILL" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHKILL" b2="69 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHKILL" b2="69 KV" b3="B7" />
      <ContingencyEquipment Action="X" Type="XF" b1="NRTHKILL" b2="230 KV" b3="BK 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89320</SeqNum>
    <Name>L138.Star-Tusc</Name>
    <LastEdit Timestamp="2025-05-09T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAR_FE" b2="138 KV" b3="120" />
      <ContingencyEquipment Action="L" Type="LN" b1="STAR_FE" b2="138 KV" b3="STA-TUS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUSC" b2="138 KV" b3="B102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUSC" b2="138 KV" b3="B103" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89330</SeqNum>
    <Name>L138.Holloway-Nottingham.4</Name>
    <LastEdit Timestamp="2024-08-27T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLLOWAY" b2="138 KV" b3="HOL-NOT4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="K6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89340</SeqNum>
    <Name>L345/138.116GoodingsGrove.TR84</Name>
    <LastEdit Timestamp="2024-08-28T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="116 GOOD" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="116 GOOD" b2="138 KV" b3="TR84CT-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="TR84HSCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89350</SeqNum>
    <Name>L345.GooseCreek-LegHorn [ILL_EQ]</Name>
    <LastEdit Timestamp="2026-02-27T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GOOSECRK" b2="345 KV" b3="GOO-LEGH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRK" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRK" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGH" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGH" b2="345 KV" b3="V15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89370</SeqNum>
    <Name>L138.Yager-Nottingham.2</Name>
    <LastEdit Timestamp="2024-08-27T15:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="J5" />
      <ContingencyEquipment Action="L" Type="LN" b1="NOTINGHA" b2="138 KV" b3="NOT-YAG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="138 KV" b3="D2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89380</SeqNum>
    <Name>L138.Harmon(FE)-Nottingham.2</Name>
    <LastEdit Timestamp="2024-08-29T10:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONOE" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARMONOE" b2="138 KV" b3="HAR-NOT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="H3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89390</SeqNum>
    <Name>L138.Holloway-Nottingham.6</Name>
    <LastEdit Timestamp="2024-08-27T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLLOWAY" b2="138 KV" b3="HOL-NOT6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="H4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89400</SeqNum>
    <Name>L115.Highpoint-Ringer Hill</Name>
    <LastEdit Timestamp="2024-08-27T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHPNT" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHPNT" b2="115 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHPNT" b2="115 KV" b3="HIG-RIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RINGERHI" b2="115 KV" b3="NJR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89410</SeqNum>
    <Name>L138.AllenIM-Zodiac.2</Name>
    <LastEdit Timestamp="2025-12-05T14:33:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENIM" b2="138 KV" b3="ALL-ZOD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008R5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008R8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89420</SeqNum>
    <Name>L345.AllenIM-RobisonPark.2</Name>
    <LastEdit Timestamp="2024-08-27T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENIM" b2="345 KV" b3="ALL-ROB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="345 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="345 KV" b3="PM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="345 KV" b3="PM1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89430</SeqNum>
    <Name>L69.CampSherman-Ross</Name>
    <LastEdit Timestamp="2024-08-30T12:40:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMPSHER" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMPSHER" b2="69 KV" b3="CAM-ROS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAMPSHER" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAMPSHER" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="69 KV" b3="F1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89440</SeqNum>
    <Name>230/115.Perryman.230-2</Name>
    <LastEdit Timestamp="2025-06-06T12:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="110461GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="110615GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="110616GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="110617GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="1106182B" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PERRYMAN" b2="230 KV" b3="230-1_2" />
      <ContingencyEquipment Action="X" Type="XF" b1="PERRYMAN" b2="230 KV" b3="230-2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PERRYMAN" b2="230 KV" b3="230-2GCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89450</SeqNum>
    <Name>230/115.Perryman.230-1</Name>
    <LastEdit Timestamp="2025-06-06T12:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="110-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="110451GC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="1106181B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="110620" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYMAN" b2="115 KV" b3="110621" />
      <ContingencyEquipment Action="X" Type="XF" b1="PERRYMAN" b2="230 KV" b3="230-1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PERRYMAN" b2="230 KV" b3="230-1GCB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PERRYMAN" b2="230 KV" b3="230-1_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89470</SeqNum>
    <Name>DTX138.Ross.TR1</Name>
    <LastEdit Timestamp="2025-10-20T10:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROSS" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89490</SeqNum>
    <Name>L138.Joffre-Imperial-NorthFayette</Name>
    <LastEdit Timestamp="2025-02-10T11:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="IMPERIAL" b2="138 KV" b3="IMP-JOF" />
      <ContingencyEquipment Action="L" Type="LN" b1="IMPERIAL" b2="138 KV" b3="IMP-NFA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IMPERIAL" b2="138 KV" b3="IMPERIAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOFFRE" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOFFRE" b2="138 KV" b3="9" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NFAYETTE" b2="138 KV" b3="SMITH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89500</SeqNum>
    <Name>L138.Joffre-Smith</Name>
    <LastEdit Timestamp="2024-08-27T15:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOFFRE" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOFFRE" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOFFRE" b2="138 KV" b3="JOF-SMI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMIT APS" b2="138 KV" b3="NORTH FA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89520</SeqNum>
    <Name>L345.RobisonPark-Hiple</Name>
    <LastEdit Timestamp="2024-11-04T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34536" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34536-37" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIPLE" b2="345 KV" b3="HIP-ROBI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="345 KV" b3="M2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="345 KV" b3="MM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89530</SeqNum>
    <Name>L345.Argenta-WeedLake</Name>
    <LastEdit Timestamp="2024-08-30T12:25:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGENTA2" b2="345 KV" b3="36F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGENTA2" b2="345 KV" b3="36H9" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARGENTA2" b2="345 KV" b3="ARG-WEE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEEDLAKE" b2="345 KV" b3="32F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEEDLAKE" b2="345 KV" b3="36H9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89550</SeqNum>
    <Name>L69.LockHaven-Lycoming.1</Name>
    <LastEdit Timestamp="2025-05-27T16:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="JERSEYSH" b2="69 KV" b3="4019" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JERSEYSH" b2="69 KV" b3="T1LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="JERSEYSH" b2="69 KV" b3="JER-LOC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="LYC1SUNB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="LYCO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="JERSEYSH" b2="69 KV" b3="JER-LYCO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="LOHA1_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="LOHA1_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89560</SeqNum>
    <Name>138/115.Altavista.T3</Name>
    <LastEdit Timestamp="2024-08-27T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAVSTA" b2="138 KV" b3="H332" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAVSTA" b2="115 KV" b3="L332" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALTAVSTA" b2="138 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89570</SeqNum>
    <Name>138/115.Altavista.T4</Name>
    <LastEdit Timestamp="2024-08-27T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAVSTA" b2="138 KV" b3="H432" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAVSTA" b2="115 KV" b3="L432" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALTAVSTA" b2="138 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89580</SeqNum>
    <Name>L69.LockHaven-Lycoming.2</Name>
    <LastEdit Timestamp="2025-05-27T16:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="JERSEYSH" b2="69 KV" b3="4019" />
      <ContingencyEquipment Action="L" Type="LN" b1="JERSEYSH" b2="69 KV" b3="JER-JERS" />
      <ContingencyEquipment Action="L" Type="LN" b1="JERSEYSH" b2="69 KV" b3="JER-LARR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JERSEYSH" b2="69 KV" b3="T2LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JERSEYSS" b2="69 KV" b3="JESTLOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LARRYSCR" b2="69 KV" b3="LACRLOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="LARRYSCR" b2="69 KV" b3="LAR-LYCO" />
      <ContingencyEquipment Action="L" Type="LN" b1="JERSEYSS" b2="69 KV" b3="JER-LOC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="LYC2FQLH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="LYCO2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOCKHAVE" b2="69 KV" b3="T2LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="LOHA2_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="LOHA2_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89590</SeqNum>
    <Name>L69.LockHaven-Lycoming.3</Name>
    <LastEdit Timestamp="2025-05-27T16:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FIRSTQUA" b2="69 KV" b3="4347" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIRSTQUA" b2="69 KV" b3="FIR-WOOL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FIRSTQUA" b2="69 KV" b3="T1LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIRSTQUA" b2="69 KV" b3="FIR-LOC3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="LYC3FLEM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="LYCO3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOCKHAVE" b2="69 KV" b3="T1LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="LOHA3_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="LOHA3_S" />
      <ContingencyEquipment Action="L" Type="LN" b1="LYCOMING" b2="69 KV" b3="LYC-WOOL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOOLRICH" b2="69 KV" b3="WOOL_LD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOOLRICH" b2="69 KV" b3="WOOL_LD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89600</SeqNum>
    <Name>L69.LockHaven-Lycoming.4</Name>
    <LastEdit Timestamp="2025-05-27T16:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FIRSTQUA" b2="69 KV" b3="4347" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIRSTQUA" b2="69 KV" b3="FIR-LYCO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FIRSTQUA" b2="69 KV" b3="T2LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIRSTQUA" b2="69 KV" b3="FIR-LOC4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="LYC4RENO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="LYCO4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="LOHA4_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="LOHA4_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89610</SeqNum>
    <Name>L115.Carolina-Hornertn-RoRapids-DarlDP-NevlFarm.81</Name>
    <LastEdit Timestamp="2026-06-01T17:38:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAROLINA" b2="115 KV" b3="8102" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CAROLINA" b2="115 KV" b3="8108" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAROLINA" b2="115 KV" b3="81G" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARLNGTN" b2="115 KV" b3="81E1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARLNGTN" b2="115 KV" b3="DAR-NEVL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DARLNGTN" b2="115 KV" b3="LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="HORNERTN" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HORNERTN" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HORNERTN" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HORNERTN" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEVLFARM" b2="115 KV" b3="81T1062" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEVLFARM" b2="115 KV" b3="81T1069" />
      <ContingencyEquipment Action="L" Type="LN" b1="RORAPDDP" b2="115 KV" b3="81F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RORAPDDP" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89620</SeqNum>
    <Name>L138.CollegeCorner-Hodgin-Randolph</Name>
    <LastEdit Timestamp="2024-08-30T12:17:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLLEGEC" b2="138 KV" b3="COL-HOD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLEGEC" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLEGEC" b2="138 KV" b3="L1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HODGIN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="HODGIN" b2="138 KV" b3="HOD-RAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RANDOLPH" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89630</SeqNum>
    <Name>L138.BluffPoint-Randolph</Name>
    <LastEdit Timestamp="2024-08-27T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLUFFPOI" b2="138 KV" b3="BLU-RAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUFFPOI" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUFFPOI" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RANDOLPH" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89670</SeqNum>
    <Name>L115.Perth-StageCoach-HickoryGrove.1022 + Stgch.SP</Name>
    <LastEdit Timestamp="2025-06-19T12:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HICKGRDP" b2="115 KV" b3="HIC-STAG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HICKGRDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERTH" b2="115 KV" b3="10161022" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERTH" b2="115 KV" b3="31T1022" />
      <ContingencyEquipment Action="L" Type="LN" b1="PERTH" b2="115 KV" b3="PER-STAG" />
      <ContingencyEquipment Action="X" Type="XF" b1="STGCOACH" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="STGCOACH" b2="34.5 KV" b3="STGCHSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89690</SeqNum>
    <Name>RAS.L230.Clover-BlackWalnut.2068 + Clover.U2</Name>
    <LastEdit Timestamp="2026-02-11T06:39:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKWAL" b2="230 KV" b3="206822" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKWAL" b2="230 KV" b3="20682204" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="206812" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKWAL" b2="230 KV" b3="BLA-CLOV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G1T2068" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="25 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G2TL9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOVER" b2="7 KV" b3="SS2LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89700</SeqNum>
    <Name>L230.MartinsCreek-Quarry</Name>
    <LastEdit Timestamp="2024-08-28T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="GEN3QUA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="QUAR_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="230 KV" b3="MACR2E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="230 KV" b3="MACR2W" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARTINSC" b2="230 KV" b3="MAR-QUA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89710</SeqNum>
    <Name>230/69.Quarry.T3</Name>
    <LastEdit Timestamp="2024-08-30T12:16:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="QUARRY" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="230 KV" b3="TRAN3_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="69 KV" b3="TRAN_3-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="69 KV" b3="TRAN_3-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89720</SeqNum>
    <Name>L115.Plywood-SedgeHill.151</Name>
    <LastEdit Timestamp="2025-11-25T16:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYWOOD" b2="115 KV" b3="127T151" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLYWOOD" b2="115 KV" b3="G1T151" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="115 KV" b3="15102" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLYWOOD" b2="115 KV" b3="151A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="115 KV" b3="151T1047" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89740</SeqNum>
    <Name>L138.Tusc-Involta-Urban</Name>
    <LastEdit Timestamp="2024-08-30T12:24:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INVOLTA" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INVOLTA" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INVOLTA" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INVOLTA" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUSC" b2="138 KV" b3="B102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUSC" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="INVOLTA" b2="138 KV" b3="INV-TUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="URBAN" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="URBAN" b2="138 KV" b3="B238" />
      <ContingencyEquipment Action="L" Type="LN" b1="INVOLTA" b2="138 KV" b3="INV-URB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89750</SeqNum>
    <Name>L138.Adams-Magley + 138/69.AdamsIM.TR1</Name>
    <LastEdit Timestamp="2026-01-23T15:42:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ADAMSIM" b2="138 KV" b3="ADA-MAG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSIM" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSIM" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSIM" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="X" Type="XF" b1="ADAMSIM" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGLEY" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89780</SeqNum>
    <Name>L138.Pidgeon-Guilford-Sammis</Name>
    <LastEdit Timestamp="2026-04-22T15:21:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GUILFRD" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GUILFRD" b2="138 KV" b3="GUILFORD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIDGEON" b2="138 KV" b3="57" />
      <ContingencyEquipment Action="L" Type="LN" b1="GUILFRD" b2="138 KV" b3="GUI-PID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="138 KV" b3="B44" />
      <ContingencyEquipment Action="L" Type="LN" b1="GUILFRD" b2="138 KV" b3="GUI-SAM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89790</SeqNum>
    <Name>L138.NorthProctorville-EastHuntington</Name>
    <LastEdit Timestamp="2024-11-08T12:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EHUNTING" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EHUNTING" b2="138 KV" b3="EHU-NPR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89800</SeqNum>
    <Name>L500.Cloverdale-Lexington.566</Name>
    <LastEdit Timestamp="2025-08-26T17:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVERD2" b2="500 KV" b3="CLO-LEX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="500 KV" b3="EE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="500 KV" b3="EE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="500 KV" b3="547T566" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="500 KV" b3="56602" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89830</SeqNum>
    <Name>138/69.Jubalear.T1</Name>
    <LastEdit Timestamp="2025-07-25T15:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="JUBALEAR" b2="138 KV" b3=".  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUBALEAR" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUBALEAR" b2="138 KV" b3="XT1_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89840</SeqNum>
    <Name>138/69.Fremont.T1</Name>
    <LastEdit Timestamp="2024-08-30T12:06:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FREMONT" b2="138 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONT" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONT" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89850</SeqNum>
    <Name>L230.Penhorn-Hudson.J2341</Name>
    <LastEdit Timestamp="2025-05-27T17:41:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="15-16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="2-15" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUDSON" b2="230 KV" b3="HUD-PENY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENHORN" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENHORN" b2="230 KV" b3="T-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENHORN" b2="230 KV" b3="TRAN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89860</SeqNum>
    <Name>L69.LeeCity-Helechawa</Name>
    <LastEdit Timestamp="2024-11-21T14:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HELECHAW" b2="69 KV" b3="CB604" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HELECHAW" b2="69 KV" b3="CB624" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HELECHAW" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HELECHAW" b2="69 KV" b3="SH_186" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEECITY" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="HELECHAW" b2="69 KV" b3="LEE-20H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89890</SeqNum>
    <Name>138/69.Lick.T6</Name>
    <LastEdit Timestamp="2024-09-12T15:04:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LICK" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICK" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICK" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="X" Type="XF" b1="LICK" b2="138 KV" b3="T6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89910</SeqNum>
    <Name>138/69.Mckinley.T5</Name>
    <LastEdit Timestamp="2024-05-14T09:57:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCKINLEY" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="X" Type="XF" b1="MCKINLEY" b2="138 KV" b3="T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCKINLEY" b2="138 KV" b3="XT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89920</SeqNum>
    <Name>138/69.MoorePark.T1</Name>
    <LastEdit Timestamp="2024-08-28T09:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MOOREPAR" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOOREPAR" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOOREPAR" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89930</SeqNum>
    <Name>138/69.Natrium.T1</Name>
    <LastEdit Timestamp="2025-10-16T11:37:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="BT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="MOB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NATRIUM2" b2="138 KV" b3="MOBILE4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="X" Type="XF" b1="NATRIUM2" b2="138 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89940</SeqNum>
    <Name>138/69.Natrium.T2</Name>
    <LastEdit Timestamp="2025-11-17T13:36:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="H007V5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="H007V8" />
      <ContingencyEquipment Action="X" Type="XF" b1="NATRIUM2" b2="138 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89950</SeqNum>
    <Name>138/69.NBellville.TR1</Name>
    <LastEdit Timestamp="2024-11-19T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOWARD2" b2="138 KV" b3="HOW-NBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBELLVIL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBELLVIL" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="X" Type="XF" b1="NBELLVIL" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89960</SeqNum>
    <Name>138/69.Newcomerstown.T4</Name>
    <LastEdit Timestamp="2025-08-21T12:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCOMER" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCOMER" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWCOMER" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89980</SeqNum>
    <Name>L138.Azalea-Yager</Name>
    <LastEdit Timestamp="2024-08-28T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AZALEA" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AZALEA" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="AZALEA" b2="138 KV" b3="AZA-YAG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="138 KV" b3="C1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>89990</SeqNum>
    <Name>L69.CoolSprings-Lank-FivePoints</Name>
    <LastEdit Timestamp="2024-01-11T10:51:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPRI" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPRI" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOLSPRI" b2="69 KV" b3="COL-LAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIVEPTS" b2="69 KV" b3="65" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIVEPTS" b2="69 KV" b3="FIV-LAN" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="LANKREA" b2="69 KV" b3="LANK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90010</SeqNum>
    <Name>L138.Sterling-ESideLima-Gomer-NDelphos</Name>
    <LastEdit Timestamp="2025-11-04T16:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ESIDELIM" b2="138 KV" b3="ESI-GOME" />
      <ContingencyEquipment Action="L" Type="LN" b1="ESIDELIM" b2="138 KV" b3="ESI-STE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ESIDELIM" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOMER" b2="138 KV" b3="GOM-NDEL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOMER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOMER" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NDELPHOS" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERLING" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERLING" b2="138 KV" b3="S1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90020</SeqNum>
    <Name>L115.Timblin-TradeCity</Name>
    <LastEdit Timestamp="2024-08-28T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMBLIN" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TIMBLIN" b2="115 KV" b3="TIM-TRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRADECIT" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRADECIT" b2="115 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90030</SeqNum>
    <Name>L138.AllenIM-Logtown</Name>
    <LastEdit Timestamp="2025-11-14T09:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGTOWN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENIM" b2="138 KV" b3="ALL-LOG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGTOWN" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90050</SeqNum>
    <Name>L138.Nottingham-Freebyrd</Name>
    <LastEdit Timestamp="2024-08-28T11:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FREEBYRD" b2="138 KV" b3="FRE-NOT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEBYRD" b2="138 KV" b3="Q4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEBYRD" b2="138 KV" b3="R4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTINGHA" b2="138 KV" b3="P7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90060</SeqNum>
    <Name>138/69.SouthBend.T5</Name>
    <LastEdit Timestamp="2025-12-17T11:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SBENDAEP" b2="138 KV" b3="5-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SBENDAEP" b2="69 KV" b3="5-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SBENDAEP" b2="34 KV" b3="5T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBENDAEP" b2="69 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBENDAEP" b2="34 KV" b3="S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SBENDAEP" b2="34 KV" b3="T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBENDAEP" b2="138 KV" b3="XT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90070</SeqNum>
    <Name>138/69.SouthCoshocton.T2</Name>
    <LastEdit Timestamp="2024-08-30T12:09:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SCOSHOCT" b2="138 KV" b3="2-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOSHOCT" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOSHOCT" b2="138 KV" b3="I" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOSHOCT" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCOSHOCT" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCOSHOCT" b2="69 KV" b3="T3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCOSHOCT" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOSHOCT" b2="138 KV" b3="XT4CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90080</SeqNum>
    <Name>L138.Sullgard-Walters</Name>
    <LastEdit Timestamp="2024-08-30T12:48:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLGARD" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="SULLGARD" b2="138 KV" b3="SUL-WAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALTERS" b2="138 KV" b3="3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90090</SeqNum>
    <Name>L230.ParagonPark-SterlingPark.2150</Name>
    <LastEdit Timestamp="2025-09-11T09:57:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PARAGNPK" b2="230 KV" b3="21502207" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARAGNPK" b2="230 KV" b3="215032" />
      <ContingencyEquipment Action="L" Type="LN" b1="PARAGNPK" b2="230 KV" b3="PAR-STE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERLNPK" b2="230 KV" b3="20792150" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERLNPK" b2="230 KV" b3="H372CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="STERLNPK" b2="230 KV" b3="TX_3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STERLNPK" b2="35 KV" b3="TX_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90130</SeqNum>
    <Name>L138.Whitewood-KeenMountain</Name>
    <LastEdit Timestamp="2025-04-24T14:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENMOUN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRASSYCR" b2="138 KV" b3="GRA-KEE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEENMOUN" b2="138 KV" b3="KEE-WHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEWD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEWD" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90160</SeqNum>
    <Name>L138.Richland-Whitewood</Name>
    <LastEdit Timestamp="2024-08-28T11:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLAND" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLAND" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEWD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEWD" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="RICHLAND" b2="138 KV" b3="RIC-WHI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90170</SeqNum>
    <Name>L500.PeachBottom.BusTie.1</Name>
    <LastEdit Timestamp="2025-09-04T14:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="15 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="205 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="235 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="25 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="PEACHBOT" b2="500 KV" b3="BUSTIE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90180</SeqNum>
    <Name>L500.PeachBottom.BusTie.2</Name>
    <LastEdit Timestamp="2025-03-10T15:36:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="225 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="255 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="45 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="500 KV" b3="55 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="PEACHBOT" b2="500 KV" b3="BUSTIE2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90190</SeqNum>
    <Name>L230.McCarter-StanleyTerrace.J-2315</Name>
    <LastEdit Timestamp="2025-05-19T15:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCCARTER" b2="230 KV" b3="MCC-STA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANLEYT" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="STANLEYT" b2="230 KV" b3="REACTOR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STANLEYT" b2="230 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90200</SeqNum>
    <Name>Sewaren.CC</Name>
    <LastEdit Timestamp="2024-11-21T15:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="1-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN7" b2="230 KV" b3="52-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN7" b2="230 KV" b3="52-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEWAREN7" b2="230 KV" b3="7GTB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEWAREN7" b2="230 KV" b3="7GTL" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SEWAREN7" b2="25 KV" b3="CT7" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEWAREN" b2="230 KV" b3="SEW-SEW" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SEWAREN7" b2="18 KV" b3="ST7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90220</SeqNum>
    <Name>L138.Turner-SouthRidge-Chesterfield</Name>
    <LastEdit Timestamp="2024-08-30T12:19:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTER2" b2="138 KV" b3="CHE-SOU" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOUTHRID" b2="138 KV" b3="SOU-TUR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOUTHRID" b2="138 KV" b3="T-12KV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="E1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90230</SeqNum>
    <Name>L138.CabinCreek-FieldsCreek</Name>
    <LastEdit Timestamp="2025-01-28T17:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINCRE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="CABINCRE" b2="138 KV" b3="CAB-FIEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDCRE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDCRE" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90240</SeqNum>
    <Name>L138.CabinCreek-Chesterfield</Name>
    <LastEdit Timestamp="2024-08-29T09:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CABINCRE" b2="138 KV" b3="CAB-CHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINCRE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER2" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90260</SeqNum>
    <Name>L138.Albion-SkinLake-Kendallville</Name>
    <LastEdit Timestamp="2024-08-29T09:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBIONIM" b2="138 KV" b3="ALB-SKI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBIONIM" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENDALLV" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENDALLV" b2="138 KV" b3="KEN-SKI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SKINLAKE" b2="138 KV" b3="SKI-SKI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SKINNERL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90270</SeqNum>
    <Name>L138.GarrettN-MinerRd-Bixler-Kendallville</Name>
    <LastEdit Timestamp="2024-08-30T12:38:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BIXLER" b2="138 KV" b3="BIX-BIX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BIXLER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIXLERTP" b2="138 KV" b3="BIX-KEN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARRETTN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="KENDALLV" b2="138 KV" b3="CAPB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENDALLV" b2="138 KV" b3="DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENDALLV" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENDALLV" b2="69 KV" b3="M" />
      <ContingencyEquipment Action="X" Type="XF" b1="KENDALLV" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENDALLV" b2="138 KV" b3="XT3" />
      <ContingencyEquipment Action="L" Type="LN" b1="MINERD1" b2="138 KV" b3="BIX-MIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MINERD1" b2="138 KV" b3="COAVILL" />
      <ContingencyEquipment Action="L" Type="LN" b1="MINERD1" b2="138 KV" b3="GAR-MIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90280</SeqNum>
    <Name>L138.NDelphos-Logtown</Name>
    <LastEdit Timestamp="2024-08-29T09:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGTOWN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGTOWN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NDELPHOS" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOGTOWN" b2="138 KV" b3="LOG-NDEL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90290</SeqNum>
    <Name>138/69.NDelphos.T1</Name>
    <LastEdit Timestamp="2024-08-29T08:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NDELPHOS" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NDELPHOS" b2="69 KV" b3="XB1L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NDELPHOS" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90320</SeqNum>
    <Name>L230.SkiffesCreek-Warwick-Whealton.2138</Name>
    <LastEdit Timestamp="2025-06-17T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="230 KV" b3="213872" />
      <ContingencyEquipment Action="L" Type="LN" b1="SKFFSCRK" b2="230 KV" b3="2138A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="230 KV" b3="XT2138" />
      <ContingencyEquipment Action="L" Type="LN" b1="WARWICK" b2="230 KV" b3="2138B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARWICK" b2="230 KV" b3="H312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARWICK" b2="230 KV" b3="H412" />
      <ContingencyEquipment Action="X" Type="XF" b1="WARWICK" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WARWICK" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="WARWICK" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WARWICK" b2="35 KV" b3="TX4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEALTON" b2="230 KV" b3="213842" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEALTON" b2="230 KV" b3="234T2138" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90330</SeqNum>
    <Name>230/115.Whealton.TX1</Name>
    <LastEdit Timestamp="2025-01-03T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEALTON" b2="230 KV" b3="H142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEALTON" b2="115 KV" b3="L142" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHEALTON" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90340</SeqNum>
    <Name>L138.Dobbins-Pennant-Toronto</Name>
    <LastEdit Timestamp="2024-08-30T12:27:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOBINS" b2="138 KV" b3="B93" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOBINS" b2="138 KV" b3="B94" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOBINS" b2="138 KV" b3="DOB-PEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENNANT" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENNANT" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENNANT" b2="138 KV" b3="PEN-TORO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="138 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORONTO" b2="138 KV" b3="B16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90350</SeqNum>
    <Name>L138.Dobbins-Lowellville</Name>
    <LastEdit Timestamp="2025-03-17T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOBINS" b2="138 KV" b3="B91" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOBINS" b2="138 KV" b3="B92" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOWELL" b2="138 KV" b3="A22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWELL" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOWELL" b2="138 KV" b3="LOW-DOB1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90360</SeqNum>
    <Name>L345.Palisades-Segreto.3</Name>
    <LastEdit Timestamp="2025-02-10T11:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="31F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="31H9" />
      <ContingencyEquipment Action="L" Type="LN" b1="PALISAD2" b2="345 KV" b3="PAL-SEG3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEGRETO" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEGRETO" b2="345 KV" b3="C1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90370</SeqNum>
    <Name>L138.Bradley-MollysCreek-Nuttall</Name>
    <LastEdit Timestamp="2025-12-16T11:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRADLEY" b2="138 KV" b3="BRA-MOL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADLEY" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOLLYCRK" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOLLYCRK" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOLLYCRK" b2="138 KV" b3="MOL-NUT" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOLLYCRK" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOLLYCRK" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NUTTALL" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NUTTALL" b2="138 KV" b3="L2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90390</SeqNum>
    <Name>L138.BlackRiver-Charleston</Name>
    <LastEdit Timestamp="2024-08-29T09:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="9" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKRIV" b2="138 KV" b3="BLA-CHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLSTN" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLSTN" b2="138 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90400</SeqNum>
    <Name>L138.Charleston-Lorain</Name>
    <LastEdit Timestamp="2024-08-29T09:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02LORAIN" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLSTN" b2="138 KV" b3="CHA-02L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLSTN" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLSTN" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90420</SeqNum>
    <Name>L138.Muskingum-SouthCaldwell.1</Name>
    <LastEdit Timestamp="2024-08-29T09:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="138 KV" b3="HF" />
      <ContingencyEquipment Action="L" Type="LN" b1="MUSKING2" b2="138 KV" b3="MUS-SCA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCALDWEL" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCALDWEL" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90430</SeqNum>
    <Name>L138.Muskingum-SouthCaldwell.2</Name>
    <LastEdit Timestamp="2024-08-30T11:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="138 KV" b3="HE" />
      <ContingencyEquipment Action="L" Type="LN" b1="MUSKING2" b2="138 KV" b3="MUS-SCA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCALDWEL" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCALDWEL" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90440</SeqNum>
    <Name>L138.SouthCaldwell-SouthCumberland</Name>
    <LastEdit Timestamp="2024-09-03T13:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCALDWEL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCALDWEL" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCALDWEL" b2="138 KV" b3="SCA-SCU" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCUMBERL" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCUMBERL" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCUMBERL" b2="34 KV" b3="1-T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCUMBERL" b2="34 KV" b3="CALDWELL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCUMBERL" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCUMBERL" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCUMBERL" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="RANNELL" b2="69 KV" b3="RAN-SCUM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90450</SeqNum>
    <Name>L138.SCaldwell-Caldwell-BallHollow-Herlan</Name>
    <LastEdit Timestamp="2024-11-05T15:00:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BALLHOLL" b2="138 KV" b3="BAL-HER" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BALLHOLL" b2="138 KV" b3="T1 LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BALLHOLL" b2="138 KV" b3="BAL-CAL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CALDWELL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CALDWELL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERLAN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERLAN" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCALDWEL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCALDWEL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CALDWELL" b2="138 KV" b3="CAL-SCA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90460</SeqNum>
    <Name>Montpelier.U1&amp;2 (Keystne)</Name>
    <LastEdit Timestamp="2024-09-03T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTNE" b2="345 KV" b3="JJ" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEYSTNE" b2="13 KV" b3="UN1" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEYSTNE" b2="13 KV" b3="UN2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEYSTNE" b2="13 KV" b3="_UN1__15" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEYSTNE" b2="13 KV" b3="_UN2__15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90470</SeqNum>
    <Name>Montpelier.U3&amp;4 (Keystne)</Name>
    <LastEdit Timestamp="2024-09-03T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTNE" b2="345 KV" b3="HH" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEYSTNE" b2="13 KV" b3="UN3" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEYSTNE" b2="345 KV" b3="UN34" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEYSTNE" b2="13 KV" b3="UN4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEYSTNE" b2="13 KV" b3="_UN3__15" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEYSTNE" b2="13 KV" b3="_UN4__15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90480</SeqNum>
    <Name>L138.NewLondon-BrushTavern</Name>
    <LastEdit Timestamp="2025-10-15T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUSHTAV" b2="138 KV" b3="BRU-NEW1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BRUSHTAV" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUSHTAV" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUSHTAV" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUSHTAV" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLONDO" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90490</SeqNum>
    <Name>L138/69.Skenton.T1&amp;2</Name>
    <LastEdit Timestamp="2025-08-07T12:15:41" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SKENTON" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKENTON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKENTON" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKENTON" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENTON2" b2="69 KV" b3="KEN-SKE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENTON2" b2="69 KV" b3="KEN-SKE2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SKENTON" b2="69 KV" b3="LOAD 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LYNNST" b2="138 KV" b3="LYN-SKE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SKENTON" b2="138 KV" b3="SKE-WIL1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SKENTON" b2="138 KV" b3="T1 XF" />
      <ContingencyEquipment Action="X" Type="XF" b1="SKENTON" b2="138 KV" b3="T2 XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90500</SeqNum>
    <Name>SouthAnderson.U1</Name>
    <LastEdit Timestamp="2024-09-03T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDERSO" b2="138 KV" b3="G1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SANDERSO" b2="13.8 KV" b3="SAN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90510</SeqNum>
    <Name>SouthAnderson.U2</Name>
    <LastEdit Timestamp="2024-09-03T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDERSO" b2="138 KV" b3="G2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SANDERSO" b2="13.8 KV" b3="SAN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90520</SeqNum>
    <Name>SouthAnderson.U3</Name>
    <LastEdit Timestamp="2024-09-03T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDERSO" b2="138 KV" b3="GEN3 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SANDERSO" b2="13.8 KV" b3="SAN3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90590</SeqNum>
    <Name>L138.Ashtabula-Sanborn-Austinburg-LeroyCenter.Q1</Name>
    <LastEdit Timestamp="2024-09-03T13:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="AUSTNBG" b2="138 KV" b3="AUS-04S1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEROYCEN" b2="138 KV" b3="LER-AUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B78" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B79" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SANBORN" b2="138 KV" b3="111" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASHTABUL" b2="138 KV" b3="ASH-04S1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANBORN" b2="138 KV" b3="Q1_T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90620</SeqNum>
    <Name>230/138.Linden.220-1</Name>
    <LastEdit Timestamp="2024-12-18T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="138 KV" b3="1-15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="138 KV" b3="15-16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90680</SeqNum>
    <Name>138/34.48Highland.TR78</Name>
    <LastEdit Timestamp="2024-11-06T12:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="48 HIGHL" b2="138 KV" b3="TR78 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="48 HIGHL" b2="34.5 KV" b3="TR78 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="48 HIGHL" b2="138 KV" b3="TR78 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90740</SeqNum>
    <Name>345/34.EastWhitley.T2</Name>
    <LastEdit Timestamp="2024-08-30T17:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EWHITLEY" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWHITLEY" b2="34 KV" b3="52-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWHITLEY" b2="345 KV" b3="X2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90750</SeqNum>
    <Name>345/34.EastWhitley.T3</Name>
    <LastEdit Timestamp="2024-08-30T17:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EWHITLEY" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWHITLEY" b2="34 KV" b3="52-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWHITLEY" b2="345 KV" b3="X3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90760</SeqNum>
    <Name>345/138.AllenIM.T1</Name>
    <LastEdit Timestamp="2024-09-06T13:50:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="G1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALLENIM" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90780</SeqNum>
    <Name>L69.MorganCounty-Index-LeeCity</Name>
    <LastEdit Timestamp="2024-09-03T14:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="INDEX" b2="69 KV" b3="IND-LEE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INDEX" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEECITY" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANCO" b2="69 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="INDEX" b2="69 KV" b3="IND-MORC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90790</SeqNum>
    <Name>L69.MorganCounty-Morehead</Name>
    <LastEdit Timestamp="2024-09-03T14:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOREHEAD" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANCO" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOREHEAD" b2="69 KV" b3="MORC-MOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90800</SeqNum>
    <Name>L69.Centerville-RichmondPeak (CIN)</Name>
    <LastEdit Timestamp="2026-03-26T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTECIN" b2="69 KV" b3="157BRK" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTECIN" b2="69 KV" b3="CEN-RIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHMOPK" b2="69 KV" b3="CV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90810</SeqNum>
    <Name>L69.RichmondPeak-McMinnRd-08RoseBG (CIN)</Name>
    <LastEdit Timestamp="2024-09-03T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08ROSEBG" b2="69 KV" b3="115-19LS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08ROSEBG" b2="69 KV" b3="6919BP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08ROSEBG" b2="69 KV" b3="6919BRK" />
      <ContingencyEquipment Action="L" Type="LN" b1="08ROSEBG" b2="69 KV" b3="08R-MCM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCMINNRD" b2="69 KV" b3="1LSW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCMINNRD" b2="69 KV" b3="2LSW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCMINNRD" b2="69 KV" b3="6912BKSW" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCMINNRD" b2="69 KV" b3="BK1 69" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCMINNRD" b2="69 KV" b3="MCM-RIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHMOPK" b2="69 KV" b3="RB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90820</SeqNum>
    <Name>L69.SToronto-WToronto-Stratton-Carrolgr-Hammonds</Name>
    <LastEdit Timestamp="2024-09-03T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARROLGR" b2="69 KV" b3="CAR-HAM1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARROLGR" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMMONDS" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STORONT2" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="STORONT2" b2="69 KV" b3="STO-WTO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARROLGR" b2="69 KV" b3="CAR-STR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STRATTON" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STRATTON" b2="69 KV" b3="STR-WTO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WTORONTO" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90840</SeqNum>
    <Name>138/69.Oakley.BK9</Name>
    <LastEdit Timestamp="2024-09-03T13:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="138 KV" b3="802" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="138 KV" b3="803" />
      <ContingencyEquipment Action="X" Type="XF" b1="08OAKLEY" b2="138 KV" b3="BK9_P" />
      <ContingencyEquipment Action="X" Type="XF" b1="08OAKLEY" b2="69 KV" b3="BK9_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="69 KV" b3="CB606" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="69 KV" b3="CB706" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90850</SeqNum>
    <Name>L138.PortUnion-Cornell-WardsCorner-Summerside</Name>
    <LastEdit Timestamp="2025-01-24T09:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08SMRSD1" b2="138 KV" b3="840" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08SMRSD1" b2="138 KV" b3="842" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CORNELL" b2="138 KV" b3="979" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORNELL" b2="138 KV" b3="08C-08C3" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORNL_TP" b2="138 KV" b3="COR-WAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUNIO" b2="138 KV" b3="834" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORNL_TP" b2="138 KV" b3="COR-PORT" />
      <ContingencyEquipment Action="L" Type="LN" b1="08SMRSD1" b2="138 KV" b3="08S-WAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WARDS_C" b2="138 KV" b3="BK1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90860</SeqNum>
    <Name>138/69.Central.BK3</Name>
    <LastEdit Timestamp="2024-09-03T13:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08CNTRAL" b2="69 KV" b3="676" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08CNTRAL" b2="138 KV" b3="922" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08CNTRAL" b2="138 KV" b3="924" />
      <ContingencyEquipment Action="X" Type="XF" b1="08CNTRAL" b2="138 KV" b3="BK3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90870</SeqNum>
    <Name>L138.Central-Oakley</Name>
    <LastEdit Timestamp="2024-09-03T13:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08CNTRAL" b2="138 KV" b3="922" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08CNTRAL" b2="138 KV" b3="928" />
      <ContingencyEquipment Action="L" Type="LN" b1="08OAKLEY" b2="138 KV" b3="CEN-OAK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="138 KV" b3="801" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="138 KV" b3="802" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90880</SeqNum>
    <Name>L138.Central-Ashland</Name>
    <LastEdit Timestamp="2024-09-03T13:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08ASHLD7" b2="138 KV" b3="859" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08ASHLD7" b2="138 KV" b3="872" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08CNTRAL" b2="138 KV" b3="926" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08CNTRAL" b2="138 KV" b3="928" />
      <ContingencyEquipment Action="L" Type="LN" b1="08ASHLD7" b2="138 KV" b3="CEN-ASH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90890</SeqNum>
    <Name>138/69.Ross.T3</Name>
    <LastEdit Timestamp="2024-08-30T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ROSS" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="69 KV" b3="F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="69 KV" b3="G1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90900</SeqNum>
    <Name>L138.Britton-Davidson.1</Name>
    <LastEdit Timestamp="2024-08-30T17:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRITTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRITTON" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIDSON" b2="138 KV" b3="AC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIDSON" b2="138 KV" b3="AD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRITTON" b2="138 KV" b3="BRI-DAV1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90910</SeqNum>
    <Name>138/69.KingsCreek.AT2</Name>
    <LastEdit Timestamp="2025-05-06T11:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="137" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="69 KV" b3="63CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="69 KV" b3="64CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="KINGSCRK" b2="138 KV" b3="AT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90920</SeqNum>
    <Name>138/23.Valley.TR3</Name>
    <LastEdit Timestamp="2024-12-12T13:32:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="138 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="138 KV" b3="3-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="VALL DUQ" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="23 KV" b3="TR3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="138 KV" b3="Z-82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="138 KV" b3="Z-84" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>90930</SeqNum>
    <Name>138/23.Valley.TR1</Name>
    <LastEdit Timestamp="2024-12-12T13:31:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="138 KV" b3="1-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="VALL DUQ" b2="138 KV" b3="T1 XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="23 KV" b3="T1 XF CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALL DUQ" b2="138 KV" b3="Z-181" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91150</SeqNum>
    <Name>L230.HewittRoad-Ryceville.2320E</Name>
    <LastEdit Timestamp="2025-06-16T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="230 KV" b3="770" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="230 KV" b3="850" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEWITTRD" b2="230 KV" b3="HEW-RYC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RYCEVILL" b2="230 KV" b3="540" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91160</SeqNum>
    <Name>L230.HewittRoad-Ryceville.2320W</Name>
    <LastEdit Timestamp="2025-06-16T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="230 KV" b3="829" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="230 KV" b3="860" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEWITTRD" b2="230 KV" b3="HEW-RYC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RYCEVILL" b2="230 KV" b3="536" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91170</SeqNum>
    <Name>230/69.HewittRoad.T3</Name>
    <LastEdit Timestamp="2024-09-03T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="69 KV" b3="797" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="69 KV" b3="815" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="69 KV" b3="818" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="230 KV" b3="829" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="230 KV" b3="850" />
      <ContingencyEquipment Action="X" Type="XF" b1="HEWITTRD" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91180</SeqNum>
    <Name>230/69.HewittRoad.T4</Name>
    <LastEdit Timestamp="2024-09-03T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="230 KV" b3="770" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="69 KV" b3="775" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="69 KV" b3="780" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="69 KV" b3="784" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="230 KV" b3="834" />
      <ContingencyEquipment Action="X" Type="XF" b1="HEWITTRD" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91190</SeqNum>
    <Name>L230.HollandCliff-Aquasco.2350</Name>
    <LastEdit Timestamp="2026-03-31T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUASCO" b2="230 KV" b3="1110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="230 KV" b3="1220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="230 KV" b3="1225" />
      <ContingencyEquipment Action="L" Type="LN" b1="AQUASCO" b2="230 KV" b3="AQU-HOL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91200</SeqNum>
    <Name>L230.HollandCliff-Aquasco.2355</Name>
    <LastEdit Timestamp="2026-03-31T15:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUASCO" b2="230 KV" b3="1120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="230 KV" b3="1200" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="230 KV" b3="1205" />
      <ContingencyEquipment Action="L" Type="LN" b1="AQUASCO" b2="230 KV" b3="AQU-HOL2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91210</SeqNum>
    <Name>230/69.HollandCliff.T1</Name>
    <LastEdit Timestamp="2024-09-03T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="230 KV" b3="1200" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="230 KV" b3="1220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="69 KV" b3="1240" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="69 KV" b3="1260" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOLLANDC" b2="230 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91220</SeqNum>
    <Name>230/69.HollandCliff.T2</Name>
    <LastEdit Timestamp="2024-09-03T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="230 KV" b3="1210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="230 KV" b3="1230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="69 KV" b3="1250" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="69 KV" b3="1270" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOLLANDC" b2="230 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91230</SeqNum>
    <Name>L230.HollandCliff-SollersWharf.2340</Name>
    <LastEdit Timestamp="2024-09-03T14:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="230 KV" b3="1225" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="230 KV" b3="1230" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLLANDC" b2="230 KV" b3="HOL-SOL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOLLERSW" b2="230 KV" b3="1320" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOLLERSW" b2="230 KV" b3="1325" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91240</SeqNum>
    <Name>L230.HollandCliff-SollersWharf.2345</Name>
    <LastEdit Timestamp="2024-09-03T14:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="230 KV" b3="1205" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLANDC" b2="230 KV" b3="1210" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOLLANDC" b2="230 KV" b3="HOL-SOL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOLLERSW" b2="230 KV" b3="1300" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOLLERSW" b2="230 KV" b3="1310" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91250</SeqNum>
    <Name>230/69.SollersWharf.T1</Name>
    <LastEdit Timestamp="2024-09-03T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SOLLERSW" b2="230 KV" b3="1300" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOLLERSW" b2="230 KV" b3="1320" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOLLERSW" b2="69 KV" b3="1340" />
      <ContingencyEquipment Action="X" Type="XF" b1="SOLLERSW" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91260</SeqNum>
    <Name>230/69.SollersWharf.T2</Name>
    <LastEdit Timestamp="2024-09-03T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SOLLERSW" b2="230 KV" b3="1310" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOLLERSW" b2="230 KV" b3="1330" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOLLERSW" b2="69 KV" b3="1350" />
      <ContingencyEquipment Action="X" Type="XF" b1="SOLLERSW" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91270</SeqNum>
    <Name>L230.HewittRoad-SollersWharf.2330</Name>
    <LastEdit Timestamp="2024-09-06T12:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="230 KV" b3="834" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEWITTRD" b2="230 KV" b3="860" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEWITTRD" b2="230 KV" b3="HEW-SOL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOLLERSW" b2="230 KV" b3="1325" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOLLERSW" b2="230 KV" b3="1330" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91310</SeqNum>
    <Name>230/69.Quarry.T2</Name>
    <LastEdit Timestamp="2024-09-06T13:48:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="QUARRY" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="230 KV" b3="TRAN2E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="230 KV" b3="TRAN2W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="69 KV" b3="TRAN2_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="69 KV" b3="TRAN2_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91320</SeqNum>
    <Name>L230.NewFreedom-SilverLake.C-2255/2306</Name>
    <LastEdit Timestamp="2024-09-06T12:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="1-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="2-10 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWFREED" b2="230 KV" b3="NEW-SIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERLA" b2="230 KV" b3="OCB B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91330</SeqNum>
    <Name>L230.Larrabee-Oceanview</Name>
    <LastEdit Timestamp="2024-09-06T12:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRABEE" b2="230 KV" b3="B93" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRABEE" b2="230 KV" b3="B96" />
      <ContingencyEquipment Action="L" Type="LN" b1="LARRABEE" b2="230 KV" b3="LAR-OCE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANVIE" b2="230 KV" b3="B55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANVIE" b2="230 KV" b3="B67" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91340</SeqNum>
    <Name>L138.Zodiac-Waynetra-Hillcrest</Name>
    <LastEdit Timestamp="2026-03-04T10:41:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HILLCRES" b2="138 KV" b3="HIL-WAY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLCRES" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAYNETRA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAYNETRA" b2="138 KV" b3="WAY-ZODI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008M5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008M8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91350</SeqNum>
    <Name>138/69.Corey.T3</Name>
    <LastEdit Timestamp="2024-09-06T12:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COREY" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COREY" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="X" Type="XF" b1="COREY" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COREY" b2="69 KV" b3="XB3L CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91380</SeqNum>
    <Name>L138.Beaver-Henrietta</Name>
    <LastEdit Timestamp="2025-12-08T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="193" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="196" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HENRIETA" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HENRIETA" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="HENRIETA" b2="138 KV" b3="BEA-HEN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91400</SeqNum>
    <Name>L345.Goethals-Lincogen.G23L</Name>
    <LastEdit Timestamp="2025-05-20T11:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="9" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOETHALS" b2="345 KV" b3="GOE-LINC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOGEN" b2="345 KV" b3="52-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOGEN" b2="345 KV" b3="52-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91410</SeqNum>
    <Name>L345.Goethals-Lincogen.G23M + Lincogen.Cogen</Name>
    <LastEdit Timestamp="2025-01-27T14:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="8" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOGEN" b2="345 KV" b3="LIN-GOE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOGEN" b2="13 KV" b3="1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOGEN" b2="345 KV" b3="52-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOGEN" b2="345 KV" b3="52-4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINCOGEN" b2="13 KV" b3="COGEN" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINCOGEN" b2="345 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91420</SeqNum>
    <Name>L345.Farragut-Gowanus.41</Name>
    <LastEdit Timestamp="2024-11-15T11:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARRAGUT" b2="345 KV" b3="6E CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARRAGUT" b2="345 KV" b3="7E CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARRAGUT" b2="345 KV" b3="FAR-GOW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOWANUS" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOWANUS" b2="345 KV" b3="4" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GOWANUS" b2="345 KV" b3="R4" />
      <ContingencyEquipment Action="S" Type="SD" b1="GOWANUS" b2="345 KV" b3="R41" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91430</SeqNum>
    <Name>L345.Farragut-Gowanus.42</Name>
    <LastEdit Timestamp="2024-11-15T11:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARRAGUT" b2="345 KV" b3="6W CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARRAGUT" b2="345 KV" b3="7W CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARRAGUT" b2="345 KV" b3="FAR-GOW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOWANUS" b2="345 KV" b3="14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOWANUS" b2="345 KV" b3="16" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GOWANUS" b2="345 KV" b3="R18" />
      <ContingencyEquipment Action="S" Type="SD" b1="GOWANUS" b2="345 KV" b3="R42" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91460</SeqNum>
    <Name>138/69.Hodgin.T1</Name>
    <LastEdit Timestamp="2024-09-06T12:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HODGIN" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HODGIN" b2="69 KV" b3="6961" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HODGIN" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91470</SeqNum>
    <Name>138/69.Hillcrest.T2</Name>
    <LastEdit Timestamp="2024-11-14T15:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HILLCRES" b2="138 KV" b3="3-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="HILLCRES" b2="69 KV" b3="3-S" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HILLCRES" b2="138 KV" b3="CAPB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLCRES" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLCRES" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILLCRES" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLCRES" b2="69 KV" b3="XB3L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLCRES" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91480</SeqNum>
    <Name>138/69.Hillcrest.T3</Name>
    <LastEdit Timestamp="2024-09-06T12:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HILLCRES" b2="138 KV" b3="3-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="HILLCRES" b2="69 KV" b3="3-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLCRES" b2="69 KV" b3="XB3L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLCRES" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91490</SeqNum>
    <Name>500/230.Sunbury.T25</Name>
    <LastEdit Timestamp="2024-10-28T12:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SUNBURY" b2="500 KV" b3="25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="TRAN25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="500 KV" b3="TRAN25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91500</SeqNum>
    <Name>L500.Sunbury-Hummel + HummelCC</Name>
    <LastEdit Timestamp="2024-10-25T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HUMMEL" b2="500 KV" b3="10" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUMMEL" b2="500 KV" b3="11" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUMMEL" b2="500 KV" b3="12" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUMMEL" b2="500 KV" b3="13" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUMMEL" b2="18 KV" b3="CTG11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUMMEL" b2="18 KV" b3="CTG12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUMMEL" b2="18 KV" b3="CTG13" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUMMEL" b2="18 KV" b3="SS12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUMMEL" b2="18 KV" b3="SS13" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HUMMEL" b2="22 KV" b3="STG" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUMMEL" b2="500 KV" b3="HUMM-SUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="500 KV" b3="HUST_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="500 KV" b3="HUST_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91510</SeqNum>
    <Name>L230.Lackawanna-Lack.EC + Lackawanna.EC.CC</Name>
    <LastEdit Timestamp="2025-07-07T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAENG" b2="230 KV" b3="0SYD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LACKAENG" b2="24 KV" b3="CTG1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LACKAENG" b2="24 KV" b3="CTG2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LACKAENG" b2="24 KV" b3="CTG3" />
      <ContingencyEquipment Action="L" Type="LN" b1="LACKAENG" b2="230 KV" b3="LAC-LAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="LAENRGY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="SMT2LAEN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91520</SeqNum>
    <Name>345/230/14.Cayuga.T9</Name>
    <LastEdit Timestamp="2024-09-09T13:34:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="345 KV" b3="01B9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAYUGA2" b2="13.8 KV" b3="1401 LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAYUGA2" b2="13.8 KV" b3="14345LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="CAYUGA2" b2="345 KV" b3="9-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="CAYUGA2" b2="230 KV" b3="9-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="CAYUGA2" b2="13.8 KV" b3="9-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="230 KV" b3="B913" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="345 KV" b3="B9G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="230 KV" b3="G1B9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91660</SeqNum>
    <Name>L138.Ebersole-FlagCity-NewLiberty</Name>
    <LastEdit Timestamp="2024-09-06T13:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBERSOLE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBERSOLE" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EBERSOLE" b2="138 KV" b3="EBE-FLA" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLAGCITY" b2="138 KV" b3="FLA-NEW" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLAGCITY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLIBER" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91670</SeqNum>
    <Name>L138.SLynchburg-GeorgeSt-Lynbrook-BrushTavern</Name>
    <LastEdit Timestamp="2024-09-06T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUSHTAV" b2="138 KV" b3="BRU-LYN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUSHTAV" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="L" Type="LN" b1="GEORGEST" b2="138 KV" b3="GEO-LYN" />
      <ContingencyEquipment Action="L" Type="LN" b1="GEORGEST" b2="138 KV" b3="GEO-SLY" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GEORGEST" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LYNBROOK" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLYNCHBU" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91680</SeqNum>
    <Name>L138.BiersRun-Hopetown-Delano</Name>
    <LastEdit Timestamp="2024-09-06T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BIERSRUN" b2="138 KV" b3="BIE-HOP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELANO" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELANO" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELANO" b2="138 KV" b3="DEL-HOP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPETOWN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPETOWN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPETOWN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPETOWN" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91700</SeqNum>
    <Name>L138.Delano-Ross</Name>
    <LastEdit Timestamp="2024-09-06T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELANO" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELANO" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELANO" b2="138 KV" b3="DEL-ROS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91710</SeqNum>
    <Name>L138.TiltonEC-WestTilton</Name>
    <LastEdit Timestamp="2025-04-08T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TILTN EC" b2="138 KV" b3="1644" />
      <ContingencyEquipment Action="L" Type="LN" b1="TILTN EC" b2="138 KV" b3="TIL-WTI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WTILT" b2="138 KV" b3="1582" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91720</SeqNum>
    <Name>L230.SkiffesCreek-Waller.2146</Name>
    <LastEdit Timestamp="2024-12-09T15:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="230 KV" b3="214672" />
      <ContingencyEquipment Action="L" Type="LN" b1="SKFFSCRK" b2="230 KV" b3="2146A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="230 KV" b3="285T2146" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALLER" b2="230 KV" b3="21022146" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALLER" b2="230 KV" b3="H542" />
      <ContingencyEquipment Action="X" Type="XF" b1="WALLER" b2="230 KV" b3="TX5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALLER" b2="35 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91730</SeqNum>
    <Name>L230.SkiffesCreek-Denbigh-Yorktown.285</Name>
    <LastEdit Timestamp="2024-11-13T13:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DENBIGH" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DENBIGH" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DENBIGH" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DENBIGH" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="230 KV" b3="28572" />
      <ContingencyEquipment Action="L" Type="LN" b1="DENBIGH" b2="230 KV" b3="285C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="230 KV" b3="285T2146" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="230 KV" b3="209T285" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="230 KV" b3="28582" />
      <ContingencyEquipment Action="L" Type="LN" b1="YORKTOW4" b2="230 KV" b3="285D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91740</SeqNum>
    <Name>L138.Belpre-Parkersburg</Name>
    <LastEdit Timestamp="2024-09-06T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELPRE" b2="138 KV" b3="BEL-PAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELPRE" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARKERSB" b2="138 KV" b3="BELPRE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91750</SeqNum>
    <Name>L138.Belpre-Degussa-Corner</Name>
    <LastEdit Timestamp="2024-10-24T14:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELPRE" b2="138 KV" b3="BEL-DEG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELPRE" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORNER" b2="138 KV" b3="COR-DEG" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CORNER" b2="138 KV" b3="DEGUSRES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORNER" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEGUSSA" b2="138 KV" b3="DEG CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DEGUSSA" b2="138 KV" b3="DEGUSSA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91760</SeqNum>
    <Name>L115.MartinsHundred-SkiffesCreek.7</Name>
    <LastEdit Timestamp="2025-06-19T10:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MARTNHND" b2="115 KV" b3="7A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTNHND" b2="115 KV" b3="H122" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARTNHND" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="115 KV" b3="772" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="115 KV" b3="WT7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91770</SeqNum>
    <Name>L345.Foster-Garver</Name>
    <LastEdit Timestamp="2025-01-27T14:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="345 KV" b3="1351" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="345 KV" b3="1353" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTER2" b2="345 KV" b3="FOS-GAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="345 KV" b3="1435" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="345 KV" b3="1442" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91780</SeqNum>
    <Name>L345.Garver-ToddHunter</Name>
    <LastEdit Timestamp="2024-10-18T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="345 KV" b3="1431" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="345 KV" b3="1433" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARVER" b2="345 KV" b3="GAR-TOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="345 KV" b3="1391" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="345 KV" b3="1393" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91790</SeqNum>
    <Name>L138.McConville-Brookville-SouthLynchburg</Name>
    <LastEdit Timestamp="2025-12-01T13:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKVI2" b2="138 KV" b3="BRO-MCC" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKVI2" b2="138 KV" b3="BRO-SLY1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BROOKVI2" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCONVIL" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCCONVIL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCONVIL" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLYNCHBU" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91800</SeqNum>
    <Name>L138.McConville-GravesMill-Reusens</Name>
    <LastEdit Timestamp="2026-01-28T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GRAVESMI" b2="138 KV" b3="GRA-REU1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRAVESMI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRAVESMI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCONVIL" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAVESMI" b2="138 KV" b3="GRA-MCC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REUSENS" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91820</SeqNum>
    <Name>L230.Lauschtown-SouthAkron</Name>
    <LastEdit Timestamp="2024-09-06T12:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAUSCHTO" b2="230 KV" b3="LAU-SAK3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="230 KV" b3="SAKRN3_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="230 KV" b3="SAKRN3_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="LAUS3_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="LAUS3_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91830</SeqNum>
    <Name>L345.Cole-Hayden</Name>
    <LastEdit Timestamp="2024-09-06T12:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="345 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLE" b2="345 KV" b3="COL-HAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYDEN" b2="345 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYDEN" b2="345 KV" b3="D1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91840</SeqNum>
    <Name>L230.Mountain-Stanton+230/69.Stanton.T1+Mountai.T2</Name>
    <LastEdit Timestamp="2025-06-17T14:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MOUN UGI" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="230 KV" b3="23020" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66240" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN UGI" b2="69 KV" b3="66270" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUN UGI" b2="230 KV" b3="MOU-STA" />
      <ContingencyEquipment Action="X" Type="XF" b1="STANTON" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANTON" b2="230 KV" b3="MOUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANTON" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91850</SeqNum>
    <Name>L230.Lackawanna-Summit.1</Name>
    <LastEdit Timestamp="2024-09-06T12:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="SMT1PAUP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="SUMIT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LACKAWAN" b2="230 KV" b3="LAC-SUM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMITPL" b2="230 KV" b3="LAC1-ST4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMITPL" b2="230 KV" b3="LACK1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91930</SeqNum>
    <Name>138/18.Eastlake.T200 &amp; SC.1.2.3 (CommonMode)</Name>
    <LastEdit Timestamp="2025-04-18T17:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G1SC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G2SC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G3SC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q1T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q2T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q3T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91940</SeqNum>
    <Name>L500.Shickshinny-Susquehanna.5067</Name>
    <LastEdit Timestamp="2025-06-04T14:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHICKSHI" b2="500 KV" b3="SUSQ E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHICKSHI" b2="500 KV" b3="SUSQ W" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHICKSHI" b2="500 KV" b3="SHI-SUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="500 KV" b3="SHIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="500 KV" b3="SUNB2TIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91960</SeqNum>
    <Name>L230.Graceton-Bagley-RaphaelRoad.2313</Name>
    <LastEdit Timestamp="2025-06-16T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAGLEY" b2="230 KV" b3="BAG-GRAC" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAGLEY" b2="230 KV" b3="BAG-RAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAGLEY" b2="230 KV" b3="SW2313" />
      <ContingencyEquipment Action="CL" Type="CB" b1="BAGLEY" b2="230 KV" b3="TIECB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRACETON" b2="230 KV" b3="2313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRACETON" b2="230 KV" b3="2313-03" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPHAERD" b2="230 KV" b3="2313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPHAERD" b2="230 KV" b3="2313_37" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91970</SeqNum>
    <Name>230/115.Earleys.TX4(&amp;TX1)</Name>
    <LastEdit Timestamp="2024-09-06T14:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="115 KV" b3="12662" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="H462" />
      <ContingencyEquipment Action="X" Type="XF" b1="EARLEYS" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EARLEYS" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="EARLEYS" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="115 KV" b3="Y62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91980</SeqNum>
    <Name>L138.Pruntytown-Grafton</Name>
    <LastEdit Timestamp="2025-08-25T11:16:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAFTON" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAFTON" b2="138 KV" b3="GRA-PRU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRAFTON" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRAFTON" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="P16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>91990</SeqNum>
    <Name>L138.Jimbranch-Yukon</Name>
    <LastEdit Timestamp="2024-10-01T16:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JIMBRANC" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="JIMBRANC" b2="138 KV" b3="JIM-YUK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKONAEP" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92000</SeqNum>
    <Name>L138.Farday-Berwind-Yukon</Name>
    <LastEdit Timestamp="2024-10-03T15:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BERWIND" b2="138 KV" b3="BER-FAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERWIND" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERWIND" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARDAY" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERWIND" b2="138 KV" b3="BER-YUK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKONAEP" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92010</SeqNum>
    <Name>L138.Dixon-StillmanValley.10721</Name>
    <LastEdit Timestamp="2025-06-20T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="107 DIXO" b2="138 KV" b3="10721" />
      <ContingencyEquipment Action="OP" Type="CB" b1="107 DIXO" b2="138 KV" b3="L10721CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="176 STIL" b2="138 KV" b3="156107CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="176 STIL" b2="34.5 KV" b3="TR78 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="176 STIL" b2="138 KV" b3="TR78_34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92020</SeqNum>
    <Name>L138.Westwood-08NW_Tap-WLafyett</Name>
    <LastEdit Timestamp="2025-04-08T10:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08NW TAP" b2="138 KV" b3="08PRD LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08NW TAP" b2="138 KV" b3="13806" />
      <ContingencyEquipment Action="L" Type="LN" b1="08NW TAP" b2="138 KV" b3="NWT-WLA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTWOOD" b2="138 KV" b3="06" />
      <ContingencyEquipment Action="L" Type="LN" b1="08NW TAP" b2="138 KV" b3="NWT-WES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLAFYETT" b2="138 KV" b3="2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92030</SeqNum>
    <Name>L138.Lemaster-Fiddlestix-SBloomin-Ross</Name>
    <LastEdit Timestamp="2024-08-22T10:31:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FIDDLEST" b2="138 KV" b3="FID-SBLO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FIDDLEST" b2="138 KV" b3="ILESBORO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMASTER" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMASTER" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIDDLEST" b2="138 KV" b3="FID-LEMA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROSS" b2="138 KV" b3="ROS-SBL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SBLOOMIN" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92040</SeqNum>
    <Name>L138.Mulberry-Ross</Name>
    <LastEdit Timestamp="2024-09-06T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MULBERRY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="MULBERRY" b2="138 KV" b3="MUL-ROS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92050</SeqNum>
    <Name>L138.NProctorville-EProctorville-Darrah</Name>
    <LastEdit Timestamp="2024-12-30T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DARRAH" b2="138 KV" b3="DAR-EPR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARRAH" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPROCTOR" b2="138 KV" b3="EPR-NPR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EPROCTOR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPROCTO2" b2="138 KV" b3="A2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92060</SeqNum>
    <Name>L138.AllenIM-Zodiac.1</Name>
    <LastEdit Timestamp="2025-12-05T14:34:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENIM" b2="138 KV" b3="ALL-ZOD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008S5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008S8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92070</SeqNum>
    <Name>L115.GreeneSt-ConstitutionStreet.110559</Name>
    <LastEdit Timestamp="2024-09-06T12:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONST ST" b2="115 KV" b3="110559" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONST ST" b2="115 KV" b3="559-567" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONST ST" b2="115 KV" b3="CON-GRE1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREE BC" b2="115 KV" b3="110-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREE BC" b2="13 KV" b3="110-2LS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREE BC" b2="115 KV" b3="553_59" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92080</SeqNum>
    <Name>L115.ConstitutionStreet-ConcordSt.110567</Name>
    <LastEdit Timestamp="2026-05-07T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC BC" b2="115 KV" b3="110-1HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC BC" b2="115 KV" b3="567564CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONC BC" b2="115 KV" b3="CON-CST1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC BC" b2="13 KV" b3="TIE CB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONST ST" b2="115 KV" b3="110567" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONST ST" b2="115 KV" b3="559-567" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92090</SeqNum>
    <Name>L230.Lauschtown-SouthReading</Name>
    <LastEdit Timestamp="2024-12-09T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAUSCHTO" b2="230 KV" b3="LAU-SRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="230 KV" b3="SAK4-SRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="230 KV" b3="SREADING" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SREADING" b2="230 KV" b3="B107252" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92100</SeqNum>
    <Name>L230.Lauschtown-SouthAkron.4</Name>
    <LastEdit Timestamp="2024-09-09T13:38:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="230 KV" b3="SAK4-SRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="230 KV" b3="SAKRN4_W" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAUSCHTO" b2="230 KV" b3="LAU-SAK4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="LAUS4_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="LAUS4_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92110</SeqNum>
    <Name>L115.Cambria-Mariner-Johnstown.996</Name>
    <LastEdit Timestamp="2024-08-20T09:05:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIA" b2="115 KV" b3="B33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIA" b2="115 KV" b3="B36" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMBRIA" b2="115 KV" b3="CAM-MAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSTOW" b2="115 KV" b3="B55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARINER" b2="115 KV" b3="AEC" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSTOW" b2="115 KV" b3="JOH-MAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92120</SeqNum>
    <Name>L138.Dorothy-Minotola</Name>
    <LastEdit Timestamp="2024-12-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DOROTHY" b2="138 KV" b3="DOR-MIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOROTHY" b2="138 KV" b3="N CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOROTHY" b2="138 KV" b3="R CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINOTOLA" b2="138 KV" b3="J CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINOTOLA" b2="138 KV" b3="K CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92210</SeqNum>
    <Name>345/138.153Taylor.TR81</Name>
    <LastEdit Timestamp="2024-11-27T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="138 KV" b3="38TR81CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="153 TAYL" b2="345 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="153 TAYL" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="153 TAYL" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92230</SeqNum>
    <Name>L345.Elderberry-Olive</Name>
    <LastEdit Timestamp="2024-10-18T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDERBER" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDERBER" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELDERBER" b2="345 KV" b3="ELD-OLI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="345 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="345 KV" b3="E1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92270</SeqNum>
    <Name>138/69/46.CedarCreek.T1</Name>
    <LastEdit Timestamp="2024-09-09T13:25:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CEDARCR2" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="CEDARCR2" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="CEDARCR2" b2="46 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCR2" b2="46 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCR2" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CEDARCR2" b2="46 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCR2" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92300</SeqNum>
    <Name>L138.Zanesville-NorthZanesville</Name>
    <LastEdit Timestamp="2024-09-09T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NZANESVI" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZANESVIL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="NZANESVI" b2="138 KV" b3="NZA-ZAN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92330</SeqNum>
    <Name>L115.Orchards-ConstitutionSt.110587</Name>
    <LastEdit Timestamp="2024-09-09T12:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONST ST" b2="115 KV" b3="110587" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONST ST" b2="115 KV" b3="B4-587" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONST ST" b2="115 KV" b3="CON-ORCH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="110587" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="587_597" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92340</SeqNum>
    <Name>L345.Hiple-EastElkhart</Name>
    <LastEdit Timestamp="2024-09-09T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="345 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EELKHART" b2="345 KV" b3="EEL-HIP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34525" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34525-26" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92350</SeqNum>
    <Name>L345.Cook-Thomson.2</Name>
    <LastEdit Timestamp="2025-06-26T11:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COOK" b2="345 KV" b3="COO-THO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="L1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOMSON" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOMSON" b2="345 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92360</SeqNum>
    <Name>345/138.EastElkhart.T2</Name>
    <LastEdit Timestamp="2026-05-18T14:53:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EELKHART" b2="345 KV" b3=".  2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="345 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="345 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="M000N5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="M000N8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92370</SeqNum>
    <Name>L138.Franklin-Landis.1410</Name>
    <LastEdit Timestamp="2024-09-09T12:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKAE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKAE" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKAE" b2="138 KV" b3="FRA-LAND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDIS" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDIS" b2="138 KV" b3="R" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92380</SeqNum>
    <Name>L138.Monroe-Landis.1404</Name>
    <LastEdit Timestamp="2024-12-17T15:49:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDIS" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANDIS" b2="138 KV" b3="LAN-MON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDIS" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="138 KV" b3="XFMROCBM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR AE" b2="138 KV" b3="XFMROCBN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92400</SeqNum>
    <Name>L138.MilanSS-Dawkins-Allen</Name>
    <LastEdit Timestamp="2024-09-09T12:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENIM" b2="138 KV" b3="ALL-DAW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="F2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAWKINS" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILANSS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILANSS" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAWKINS" b2="138 KV" b3="DAW-MIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92410</SeqNum>
    <Name>L345.BlueMound-Chestnut.9515</Name>
    <LastEdit Timestamp="2026-01-02T11:05:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="178 BLUE" b2="345 KV" b3="BT1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="178 BLUE" b2="345 KV" b3="BT1-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="178 BLUE" b2="345 KV" b3="9515" />
      <ContingencyEquipment Action="OP" Type="CB" b1="95 CHEST" b2="345 KV" b3="BT1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="95 CHEST" b2="345 KV" b3="BT1-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92420</SeqNum>
    <Name>L138.Academia-AppleValley-Salerno-NLexington</Name>
    <LastEdit Timestamp="2025-11-10T11:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ACADEMIA" b2="138 KV" b3="ACA-APP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ACADEMIA" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="APPLEVAL" b2="138 KV" b3="T6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEXINGT" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="APPLEVAL" b2="138 KV" b3="APP-SALE" />
      <ContingencyEquipment Action="L" Type="LN" b1="NLEXINGT" b2="138 KV" b3="NLE-SALE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SALERNO" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92430</SeqNum>
    <Name>L138.NLexington-Howard</Name>
    <LastEdit Timestamp="2024-09-09T12:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="L" Type="LN" b1="NLEXINGT" b2="138 KV" b3="NLE-HOW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEXINGT" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92440</SeqNum>
    <Name>L138.Roberts-Davidson</Name>
    <LastEdit Timestamp="2024-09-09T12:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIDSON" b2="138 KV" b3="AE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIDSON" b2="138 KV" b3="AF" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAVIDSON" b2="138 KV" b3="DAV-ROB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="138 KV" b3="G1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92450</SeqNum>
    <Name>L138.Davidson-BethelRoad</Name>
    <LastEdit Timestamp="2025-05-16T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHEL2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHEL2" b2="138 KV" b3="BET-DAV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHEL2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHEL2" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIDSON" b2="138 KV" b3="AD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIDSON" b2="138 KV" b3="AE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92460</SeqNum>
    <Name>L138.KyelecSt-Chadwick</Name>
    <LastEdit Timestamp="2024-09-09T12:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHADWICK" b2="138 KV" b3="CHA-KYE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHADWICK" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KYELECST" b2="138 KV" b3="T1T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KYELECST" b2="138 KV" b3="T3T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92470</SeqNum>
    <Name>L138.Bellefonte-Belhaven-Chadwick</Name>
    <LastEdit Timestamp="2024-09-09T12:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELHAVEN" b2="138 KV" b3="BEL-BEL3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELHAVEN" b2="138 KV" b3="BEL-CHA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELHAVEN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEFON" b2="138 KV" b3="LL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHADWICK" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92500</SeqNum>
    <Name>L138.Belmont-BelmontTap-Cabot-OakGrove.608</Name>
    <LastEdit Timestamp="2025-07-25T16:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B15" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="138 KV" b3="BEL-BELT" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMTAP" b2="138 KV" b3="BEL-OAKG" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMTAP" b2="138 KV" b3="BELT-ROC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYTEC" b2="138 KV" b3="CYT CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CYTEC" b2="138 KV" b3="CYT-ROC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CYTEC" b2="138 KV" b3="CYTEC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKG APS" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKG APS" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCHEVIT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCHEVIT" b2="138 KV" b3="T1 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92510</SeqNum>
    <Name>L138.Belmont-Eureka-StMarys-BensRun-LongsReach.70</Name>
    <LastEdit Timestamp="2024-05-15T09:46:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B23" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="138 KV" b3="BEL-EUR" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENSRUN" b2="138 KV" b3="BEN-LON" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENSRUN" b2="138 KV" b3="BEN-STM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENSRUN" b2="138 KV" b3="BENSRUN" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLEASNT" b2="138 KV" b3="EUR-PLE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EUREKA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGREAC" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLEASNT" b2="138 KV" b3="LD_1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLEASNT" b2="138 KV" b3="LD_2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLEASNT" b2="138 KV" b3="STM-PLE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STMARYS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92520</SeqNum>
    <Name>L138.OrdnanceJunction-ShawneeRoad</Name>
    <LastEdit Timestamp="2025-01-03T14:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ORDNANCE" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORDNANCE" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ORDNANCE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ORDNANCE" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="ORDNANCE" b2="138 KV" b3="ORD-SHA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92550</SeqNum>
    <Name>KelsonRidge.StCharles.CC</Name>
    <LastEdit Timestamp="2024-09-09T13:36:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSONRI" b2="230 KV" b3="CB10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSONRI" b2="230 KV" b3="CB11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSONRI" b2="230 KV" b3="CB12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KELSONRI" b2="18 KV" b3="LOAD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KELSONRI" b2="18 KV" b3="LOAD2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KELSONRI" b2="18 KV" b3="STCHA1CT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KELSONRI" b2="18 KV" b3="STCHA1ST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KELSONRI" b2="18 KV" b3="STCHA2CT" />
      <ContingencyEquipment Action="X" Type="XF" b1="KELSONRI" b2="230 KV" b3="TR10" />
      <ContingencyEquipment Action="X" Type="XF" b1="KELSONRI" b2="230 KV" b3="TR11" />
      <ContingencyEquipment Action="X" Type="XF" b1="KELSONRI" b2="230 KV" b3="TR12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92600</SeqNum>
    <Name>230/69.Morgantown.T1 + CT3-4</Name>
    <LastEdit Timestamp="2024-09-09T13:32:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="10AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="10BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="69 KV" b3="1A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="69 KV" b3="4A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="69 KV" b3="5A CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MORGANTO" b2="13 KV" b3="CT3" />
      <ContingencyEquipment Action="X" Type="XF" b1="MORGANTO" b2="230 KV" b3="CT3-4-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="MORGANTO" b2="13 KV" b3="CT3-4-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="MORGANTO" b2="13 KV" b3="CT3-4-T" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MORGANTO" b2="13 KV" b3="CT4" />
      <ContingencyEquipment Action="X" Type="XF" b1="MORGANTO" b2="230 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92610</SeqNum>
    <Name>230/69.Morgantown.T2 + CT5-6</Name>
    <LastEdit Timestamp="2024-09-09T13:32:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="11AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="11BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="69 KV" b3="2B CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="69 KV" b3="4B CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="69 KV" b3="5B CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MORGANTO" b2="13 KV" b3="CT5" />
      <ContingencyEquipment Action="X" Type="XF" b1="MORGANTO" b2="230 KV" b3="CT5-6-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="MORGANTO" b2="13 KV" b3="CT5-6-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="MORGANTO" b2="13 KV" b3="CT5-6-T" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MORGANTO" b2="13 KV" b3="CT6" />
      <ContingencyEquipment Action="X" Type="XF" b1="MORGANTO" b2="230 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92620</SeqNum>
    <Name>230/69.ChalkPoint.T1&amp;T3</Name>
    <LastEdit Timestamp="2025-04-08T11:13:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="2AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="2BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="69 KV" b3="3TSB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="69 KV" b3="FCB14519" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHALKPT" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHALKPT" b2="230 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92630</SeqNum>
    <Name>230/69.ChalkPoint.T2&amp;T4</Name>
    <LastEdit Timestamp="2025-04-08T11:13:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="3AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="230 KV" b3="3BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="69 KV" b3="4TSB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHALKPT" b2="69 KV" b3="FCB14520" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHALKPT" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHALKPT" b2="230 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92640</SeqNum>
    <Name>230/69.Hummelstown.T1</Name>
    <LastEdit Timestamp="2024-09-09T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HUMMELST" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="230 KV" b3="TRAN_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="69 KV" b3="TRAN_1-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="69 KV" b3="TRAN_1-W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92720</SeqNum>
    <Name>L230.Parlin-Williams-Freneau.K1025</Name>
    <LastEdit Timestamp="2025-08-22T12:22:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENEAU" b2="230 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENEAU" b2="230 KV" b3="B86" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRENEAU" b2="230 KV" b3="BK 1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRENEAU" b2="230 KV" b3="BK 3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRENEAU" b2="230 KV" b3="BK 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRENEAU" b2="230 KV" b3="FRE-WIL" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FRENEAU" b2="230 KV" b3="HOMDELSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARLIN" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARLIN" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="WILL JC" b2="230 KV" b3="WIL-PAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILL JC" b2="230 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92730</SeqNum>
    <Name>L230.NJT Aberdeen-Freneau.K1025</Name>
    <LastEdit Timestamp="2024-09-10T16:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENEAU" b2="230 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENEAU" b2="230 KV" b3="B23" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRENEAU" b2="230 KV" b3="FRE-NJT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NJTABERD" b2="230 KV" b3="UBE TX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NJTABERD" b2="230 KV" b3="UBW TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92740</SeqNum>
    <Name>L230.Glade-Warren.2088</Name>
    <LastEdit Timestamp="2024-09-10T16:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLADE" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLADE" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="230 KV" b3="B43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="230 KV" b3="B46" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLADE" b2="230 KV" b3="GLA-WAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92750</SeqNum>
    <Name>230/115.Warren.T4</Name>
    <LastEdit Timestamp="2024-12-09T15:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="230 KV" b3="B46" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="230 KV" b3="B50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="115 KV" b3="B93" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="115 KV" b3="B96" />
      <ContingencyEquipment Action="X" Type="XF" b1="WARREN" b2="230 KV" b3="NO 4 T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92770</SeqNum>
    <Name>230/115.MiddletownJct.T2</Name>
    <LastEdit Timestamp="2024-12-12T13:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="MIDDLJCT" b2="115 KV" b3="2 TX RE" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDDLJCT" b2="230 KV" b3="2T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="115 KV" b3="B109" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B19" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92780</SeqNum>
    <Name>L230.Linden-MinueStreet-Sewaren.Q-2348-3</Name>
    <LastEdit Timestamp="2024-12-16T11:09:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINDEN" b2="230 KV" b3="LIN-MINQ" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MINUEST" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="MINUEST" b2="230 KV" b3="MIN-SEW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="2-14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92790</SeqNum>
    <Name>345/230.Linden.345-1</Name>
    <LastEdit Timestamp="2024-10-18T13:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="345 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="345 KV" b3="3-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="345 KV" b3="345-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92800</SeqNum>
    <Name>345/138.Linden.345-2</Name>
    <LastEdit Timestamp="2024-12-10T13:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="138 KV" b3="13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="138 KV" b3="2-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="345 KV" b3="2-8" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="345 KV" b3="345-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="345 KV" b3="7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92810</SeqNum>
    <Name>L230.ErieSouth-Warren.2008</Name>
    <LastEdit Timestamp="2024-11-21T14:36:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIES" b2="230 KV" b3="B104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="230 KV" b3="B50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="230 KV" b3="B53" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERIES" b2="230 KV" b3="ERI-WAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92830</SeqNum>
    <Name>L345.Bunsonville-Sidney (AMIL)</Name>
    <LastEdit Timestamp="2026-05-11T15:34:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUNSONV3" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUNSONV3" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUNSONV3" b2="345 KV" b3="BUN-SIDN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIDNYCP3" b2="345 KV" b3="V33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIDNYCP3" b2="345 KV" b3="V35" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92840</SeqNum>
    <Name>L345.Ruby-Sidney</Name>
    <LastEdit Timestamp="2025-05-09T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RUBY" b2="345 KV" b3="V18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUBY" b2="345 KV" b3="V5" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUBY" b2="345 KV" b3="RUB-SIDN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIDNYCP3" b2="345 KV" b3="V23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIDNYCP3" b2="345 KV" b3="V25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92850</SeqNum>
    <Name>L345.Rising-Sidney</Name>
    <LastEdit Timestamp="2026-04-02T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="L" Type="LN" b1="RISING" b2="345 KV" b3="RIS-SID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIDNYCP3" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIDNYCP3" b2="345 KV" b3="V13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92860</SeqNum>
    <Name>L345.Rising-GooseCreek [ILL_EQ]</Name>
    <LastEdit Timestamp="2025-03-18T11:59:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRK" b2="345 KV" b3="V5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRK" b2="345 KV" b3="V7" />
      <ContingencyEquipment Action="L" Type="LN" b1="RISING" b2="345 KV" b3="RIS-GOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="345 KV" b3="V23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="345 KV" b3="V25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92870</SeqNum>
    <Name>L230.Hathaway-RockyMount(CPL).2058 &amp; Hathaway.TX2</Name>
    <LastEdit Timestamp="2026-02-19T10:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="3ROCKY" b2="230 KV" b3="6HAT_2E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3ROCKY" b2="230 KV" b3="WLSN6HAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="230 KV" b3="20582181" />
      <ContingencyEquipment Action="L" Type="LN" b1="HATHAWAY" b2="230 KV" b3="2058A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="230 KV" b3="229T2058" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="230 KV" b3="H202" />
      <ContingencyEquipment Action="X" Type="XF" b1="HATHAWAY" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92880</SeqNum>
    <Name>L230.Hathaway-Tarboro4-Tarboro.229B</Name>
    <LastEdit Timestamp="2026-01-23T09:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="230 KV" b3="22902" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="230 KV" b3="229T2058" />
      <ContingencyEquipment Action="L" Type="LN" b1="HATHAWAY" b2="230 KV" b3="HAT-TARB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TARBORO" b2="230 KV" b3="229T2177" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TARBORO" b2="230 KV" b3="H372" />
      <ContingencyEquipment Action="L" Type="LN" b1="TARBORO" b2="230 KV" b3="229B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TARBORO4" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92890</SeqNum>
    <Name>L230.Hathaway-Hornertown.2056</Name>
    <LastEdit Timestamp="2025-12-04T16:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="230 KV" b3="205602" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="230 KV" b3="20562181" />
      <ContingencyEquipment Action="L" Type="LN" b1="HATHAWAY" b2="230 KV" b3="2056A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORNERTN" b2="230 KV" b3="239T2056" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORNERTN" b2="230 KV" b3="H322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORNERTN" b2="230 KV" b3="H522" />
      <ContingencyEquipment Action="X" Type="XF" b1="HORNERTN" b2="230 KV" b3="TX3_" />
      <ContingencyEquipment Action="X" Type="XF" b1="HORNERTN" b2="230 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92900</SeqNum>
    <Name>L230.Hathaway-Nash-CtyRckMtn-RckyMt(CPL).2181</Name>
    <LastEdit Timestamp="2025-10-28T12:12:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="3ROCKY" b2="230 KV" b3="3RO-CTYR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3ROCKY" b2="230 KV" b3="6HAT_2W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3ROCKY" b2="230 KV" b3="PERS6HAT" />
      <ContingencyEquipment Action="L" Type="LN" b1="CTYRCKMT" b2="230 KV" b3="CTY-NASH" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CTYRCKMT" b2="230 KV" b3="XRM4_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="230 KV" b3="20562181" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="230 KV" b3="20582181" />
      <ContingencyEquipment Action="L" Type="LN" b1="HATHAWAY" b2="230 KV" b3="2181A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NASH" b2="230 KV" b3="H112" />
      <ContingencyEquipment Action="X" Type="XF" b1="NASH" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NASH" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92910</SeqNum>
    <Name>230/115.Hathaway.TX1</Name>
    <LastEdit Timestamp="2025-12-04T16:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="230 KV" b3="H102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="115 KV" b3="L102" />
      <ContingencyEquipment Action="X" Type="XF" b1="HATHAWAY" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92920</SeqNum>
    <Name>L115.CoolSprings-Mayo-BeechBranch.80</Name>
    <LastEdit Timestamp="2025-09-03T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BCHBRNCH" b2="115 KV" b3="8032" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BCHBRNCH" b2="115 KV" b3="80T1048" />
      <ContingencyEquipment Action="L" Type="LN" b1="BCHBRNCH" b2="115 KV" b3="BCH-MAYO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPR" b2="115 KV" b3="8052" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPR" b2="115 KV" b3="80T1032" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOLSPR" b2="115 KV" b3="COO-MAYO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAYODP" b2="115 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92930</SeqNum>
    <Name>L115.Hathaway-Battleboro.1014</Name>
    <LastEdit Timestamp="2025-12-04T16:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BATTLEBO" b2="115 KV" b3="101442" />
      <ContingencyEquipment Action="L" Type="LN" b1="BATTLEBO" b2="115 KV" b3="1014A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="115 KV" b3="101402-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="115 KV" b3="101402-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92940</SeqNum>
    <Name>L500.Carson-RogersRoad.585</Name>
    <LastEdit Timestamp="2025-05-13T20:47:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="500 KV" b3="58572-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARSON4" b2="500 KV" b3="58572-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARSON4" b2="500 KV" b3="585A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROGERSRD" b2="500 KV" b3="58532" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROGERSRD" b2="500 KV" b3="XT585" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92950</SeqNum>
    <Name>L500.BrunswickHeritage-RogersRoad.503</Name>
    <LastEdit Timestamp="2024-09-10T16:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSSWY" b2="500 KV" b3="50362" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNSSWY" b2="500 KV" b3="503A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSSWY" b2="500 KV" b3="WT503" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROGERSRD" b2="500 KV" b3="50332" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROGERSRD" b2="500 KV" b3="ZT503" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>92960</SeqNum>
    <Name>L500.Greensville-RogersRoad.596 + Greensville.CC</Name>
    <LastEdit Timestamp="2025-04-08T10:10:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="GRNSVIL" b2="500 KV" b3="1A" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRNSVIL" b2="500 KV" b3="1B" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRNSVIL" b2="500 KV" b3="1C" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRNSVIL" b2="500 KV" b3="1S" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRNSVIL" b2="500 KV" b3="596A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRNSVIL" b2="500 KV" b3="G1A02" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRNSVIL" b2="500 KV" b3="G1B02" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRNSVIL" b2="500 KV" b3="G1C02" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRNSVIL" b2="500 KV" b3="G1S02" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRNSVIL" b2="20 KV" b3="GREENCT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRNSVIL" b2="20 KV" b3="GREENCT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRNSVIL" b2="20 KV" b3="GREENCT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRNSVIL" b2="20 KV" b3="GREENSST" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRNSVIL" b2="20 KV" b3="LOAD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRNSVIL" b2="20 KV" b3="LOAD2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRNSVIL" b2="20 KV" b3="LOAD3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROGERSRD" b2="500 KV" b3="59632" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROGERSRD" b2="500 KV" b3="YT596" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93000</SeqNum>
    <Name>115/13.Churchland.TX4 </Name>
    <LastEdit Timestamp="2026-04-30T13:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRCHLND" b2="115 KV" b3="H452" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHRCHLND" b2="115 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHRCHLND" b2="13 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93040</SeqNum>
    <Name>230/35.JeffersonStreet.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-01T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="JEFFRSON" b2="230 KV" b3="H124M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFRSON" b2="230 KV" b3="SR122" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JEFFRSON" b2="230 KV" b3="SR_1" />
      <ContingencyEquipment Action="X" Type="XF" b1="JEFFRSON" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JEFFRSON" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93050</SeqNum>
    <Name>230/35.JeffersonStreet.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-01T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="JEFFRSON" b2="230 KV" b3="H224M" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="JEFFRSON" b2="230 KV" b3="SC5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFRSON" b2="230 KV" b3="SC522" />
      <ContingencyEquipment Action="X" Type="XF" b1="JEFFRSON" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JEFFRSON" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93060</SeqNum>
    <Name>L138.SouthBluefield-BluefieldAve</Name>
    <LastEdit Timestamp="2024-10-31T08:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEFIEL" b2="138 KV" b3="BLU-SBL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEFIEL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLUEFIEL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBLUEFIE" b2="138 KV" b3="R" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93090</SeqNum>
    <Name>138/69.Bellefonte.T3</Name>
    <LastEdit Timestamp="2025-10-20T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEFON" b2="69 KV" b3="AB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLEFON" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEFON" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93100</SeqNum>
    <Name>L69.HighStreet-Woodstown.0765</Name>
    <LastEdit Timestamp="2024-09-10T17:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHST" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHST" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHST" b2="69 KV" b3="HIG-WOO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSTOW" b2="69 KV" b3="U" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93110</SeqNum>
    <Name>L69.HighStreet-Paulsboro.0605</Name>
    <LastEdit Timestamp="2024-09-10T17:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHST" b2="69 KV" b3="HIG-PAU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHST" b2="69 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHST" b2="69 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAULSBRO" b2="69 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93120</SeqNum>
    <Name>230/69.Churchtown.T3</Name>
    <LastEdit Timestamp="2024-09-19T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="230 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="230 KV" b3="O" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHURCHTO" b2="230 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93130</SeqNum>
    <Name>L115.GreeneSt-ConstitutionStreet.110562</Name>
    <LastEdit Timestamp="2024-09-10T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONST ST" b2="115 KV" b3="110562" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONST ST" b2="115 KV" b3="568-562" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONST ST" b2="115 KV" b3="CON-GRE3" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREE BC" b2="115 KV" b3="110-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREE BC" b2="13 KV" b3="110-4LS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREE BC" b2="115 KV" b3="554_562" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93140</SeqNum>
    <Name>L115.ConstitutionStreet-ConcordSt.110568</Name>
    <LastEdit Timestamp="2024-06-10T18:59:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CONC BC" b2="115 KV" b3="110-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC BC" b2="13 KV" b3="110-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC BC" b2="115 KV" b3="568563CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONC BC" b2="115 KV" b3="CON-CST2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONC BC" b2="13 KV" b3="TIE CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONST ST" b2="115 KV" b3="110568" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONST ST" b2="115 KV" b3="568-562" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93150</SeqNum>
    <Name>230/138.Eddystone.T9</Name>
    <LastEdit Timestamp="2024-09-10T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="138 KV" b3="195" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="230 KV" b3="95" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDDYSTON" b2="230 KV" b3="TR9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93160</SeqNum>
    <Name>345/138.Bayway.T4+L138.Bayway-FederalSquare.K-1311</Name>
    <LastEdit Timestamp="2024-09-10T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="1-9" />
      <ContingencyEquipment Action="X" Type="XF" b1="BAYWAY" b2="345 KV" b3="345-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYWAY" b2="138 KV" b3="BAY-FED" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FEDERALS" b2="138 KV" b3="132-3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FEDERALS" b2="138 KV" b3="LOAD3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FEDERALS" b2="138 KV" b3="SECT 3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93170</SeqNum>
    <Name>L230.Sewaren-MinueStreet-Linden.R-2218</Name>
    <LastEdit Timestamp="2024-10-29T16:32:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINDEN" b2="230 KV" b3="LIN-MINR" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MINUEST" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="MINUEST" b2="230 KV" b3="MIN-SEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="1-13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="13-14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93180</SeqNum>
    <Name>L115.Warriner-WillMid-WillPott-Macnew-Lenox</Name>
    <LastEdit Timestamp="2026-04-13T15:08:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LENOX" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="LENOX" b2="115 KV" b3="LEN-MAC" />
      <ContingencyEquipment Action="L" Type="LN" b1="MACNEW_T" b2="115 KV" b3="MAC-WIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MACNEW_T" b2="115 KV" b3="MACNEW_T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINER" b2="115 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINER" b2="115 KV" b3="B20" />
      <ContingencyEquipment Action="L" Type="LN" b1="WARRINER" b2="115 KV" b3="WAR-WILL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILLIAMM" b2="115 KV" b3="MIDSTREM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WMPOTTER" b2="115 KV" b3="POTTER" />
      <ContingencyEquipment Action="L" Type="LN" b1="WILLIAMM" b2="115 KV" b3="WIL-WMP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93200</SeqNum>
    <Name>L500.TMI-Lauschtown.5026</Name>
    <LastEdit Timestamp="2024-10-31T08:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAUSCHTO" b2="500 KV" b3="LAU-TMI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="500 KV" b3="TMI_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAUSCHTO" b2="500 KV" b3="TMI_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="500 KV" b3="502602" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="500 KV" b3="502612" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93220</SeqNum>
    <Name>138/34.Guilford.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-30T15:25:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="GUILFORD" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUILFORD" b2="138 KV" b3="CAP1 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GUILFORD" b2="34.5 KV" b3="CAP2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GUILFORD" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUILFORD" b2="138 KV" b3="CAP3  CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUILFORD" b2="138 KV" b3="G12GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUILFORD" b2="138 KV" b3="G13GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUILFORD" b2="138 KV" b3="GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUILFORD" b2="13.8 KV" b3="GEN12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUILFORD" b2="13.8 KV" b3="GEN13" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUILFORD" b2="34.5 KV" b3="STT_1_SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUILFORD" b2="34.5 KV" b3="STT_2_SP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GUILFORD" b2="138 KV" b3="T1 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GUILFORD" b2="34.5 KV" b3="T1LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUILFORD" b2="138 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93240</SeqNum>
    <Name>138/69.Guilford.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-06-02T14:58:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GUILFORD" b2="69 KV" b3="BR30" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GUILFORD" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUILFORD" b2="138 KV" b3="CAP1 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GUILFORD" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUILFORD" b2="138 KV" b3="CAP3  CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUILFORD" b2="138 KV" b3="G12GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUILFORD" b2="138 KV" b3="G13GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUILFORD" b2="138 KV" b3="GEN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUILFORD" b2="13.8 KV" b3="GEN12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUILFORD" b2="13.8 KV" b3="GEN13" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GUILFORD" b2="138 KV" b3="T2 DIS" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUILFORD" b2="138 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93280</SeqNum>
    <Name>138/13.WestEnd.TR18</Name>
    <LastEdit Timestamp="2024-09-10T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="943" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="945" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WEST_END" b2="138 KV" b3="TB18" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93290</SeqNum>
    <Name>138/13.WestEnd.TR19</Name>
    <LastEdit Timestamp="2024-09-10T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="949" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="951" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WEST_END" b2="138 KV" b3="TB19" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93300</SeqNum>
    <Name>138/13.WestEnd.TR17</Name>
    <LastEdit Timestamp="2024-09-10T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="925" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="927" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WEST_END" b2="138 KV" b3="TB17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93310</SeqNum>
    <Name>138/13.WestEnd.TR15</Name>
    <LastEdit Timestamp="2024-09-10T15:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="913" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEST_END" b2="138 KV" b3="915" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WEST_END" b2="138 KV" b3="TB15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93320</SeqNum>
    <Name>138/69.Chadwick.T1</Name>
    <LastEdit Timestamp="2025-08-06T14:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CHADWICK" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHADWICK" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHADWICK" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHADWICK" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93330</SeqNum>
    <Name>L230.Glade-LewisRun</Name>
    <LastEdit Timestamp="2026-04-01T13:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLADE" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLADE" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLADE" b2="230 KV" b3="GLA-LEW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISRN" b2="230 KV" b3="B61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISRN" b2="230 KV" b3="B64" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93340</SeqNum>
    <Name>L138.Kearneysville-Vanville-Inwood</Name>
    <LastEdit Timestamp="2024-09-10T16:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INWOOD" b2="138 KV" b3="1352" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INWOOD" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="INWOOD" b2="138 KV" b3="INW-VAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INWOOD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNEYS" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEARNEYS" b2="138 KV" b3="KEA-VAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VANVILLE" b2="138 KV" b3="T19" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93350</SeqNum>
    <Name>L500.RhodesLane-Yukon.517</Name>
    <LastEdit Timestamp="2025-08-26T17:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RHODESLN" b2="500 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RHODESLN" b2="500 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="RHODESLN" b2="500 KV" b3="RHO-YUK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="500 KV" b3="B103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="500 KV" b3="B190" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93370</SeqNum>
    <Name>345/138.Austin.T1</Name>
    <LastEdit Timestamp="2024-09-10T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AUSTIN" b2="138 KV" b3="52 1" />
      <ContingencyEquipment Action="X" Type="XF" b1="AUSTIN" b2="345 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUSTIN" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUSTIN" b2="345 KV" b3="V15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93430</SeqNum>
    <Name>L345.HollandNorthwest-NeogaSouth (Ameren)</Name>
    <LastEdit Timestamp="2024-09-10T16:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HDNW" b2="345 KV" b3="3517" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HDNW" b2="345 KV" b3="3518" />
      <ContingencyEquipment Action="L" Type="LN" b1="HDNW" b2="345 KV" b3="HDN-NEO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEOGA  3" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEOGA  3" b2="345 KV" b3="V3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93450</SeqNum>
    <Name>138/69.Reusens.T2</Name>
    <LastEdit Timestamp="2025-05-19T14:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="REUSENS" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REUSENS" b2="138 KV" b3="AE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REUSENS" b2="34 KV" b3="BLACKWAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REUSENS" b2="34 KV" b3="N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93460</SeqNum>
    <Name>345/138.Pontiac.TR81</Name>
    <LastEdit Timestamp="2024-09-10T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="80 PONTI" b2="345 KV" b3="BT3-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="80 PONTI" b2="345 KV" b3="BT4-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="80 PONTI" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="80 PONTI" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93500</SeqNum>
    <Name>L138.EllisonRoad-Dalmatian-Aviation</Name>
    <LastEdit Timestamp="2024-09-10T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AVIATION" b2="138 KV" b3="AVI-DAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVIATION" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="L" Type="LN" b1="DALMATIA" b2="138 KV" b3="DAL-ELL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELLISONR" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELLISONR" b2="138 KV" b3="C1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93540</SeqNum>
    <Name>L115.Pinewood-StJohn-Woodpckr-Slbtwn-Frdrksbg.47</Name>
    <LastEdit Timestamp="2024-09-10T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRDRKSBG" b2="115 KV" b3="4742" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRDRKSBG" b2="115 KV" b3="47I" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEWOOD" b2="115 KV" b3="4702" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINEWOOD" b2="115 KV" b3="47D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEWOOD" b2="115 KV" b3="47T1013" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SLABTNDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SLABTNDP" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STJOHNS4" b2="115 KV" b3="12T47" />
      <ContingencyEquipment Action="L" Type="LN" b1="STJOHNS4" b2="115 KV" b3="47E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STJOHNS4" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SLABTNDP" b2="115 KV" b3="47F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODPKDP" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93550</SeqNum>
    <Name>L115.Pinewood-KingsDominionDP-FourRivers.1008</Name>
    <LastEdit Timestamp="2024-09-11T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="115 KV" b3="175T1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="115 KV" b3="73T1008" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOURRIVR" b2="115 KV" b3="1008B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEWOOD" b2="115 KV" b3="100802" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEWOOD" b2="115 KV" b3="10081013" />
      <ContingencyEquipment Action="L" Type="LN" b1="KDOMINDP" b2="115 KV" b3="1008A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93560</SeqNum>
    <Name>L230.Elimsport-Lycoming.3 + 230/69.Lycoming.3</Name>
    <LastEdit Timestamp="2024-09-11T16:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMSPOR" b2="230 KV" b3="ELI-LYC3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMSPOR" b2="230 KV" b3="LYCOM2E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMSPOR" b2="230 KV" b3="LYCOM3E" />
      <ContingencyEquipment Action="X" Type="XF" b1="LYCOMING" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="TRAN_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93570</SeqNum>
    <Name>230/35.Oceanview.T1</Name>
    <LastEdit Timestamp="2024-09-11T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANVIE" b2="230 KV" b3="B64" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANVIE" b2="230 KV" b3="B67" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANVIE" b2="35 KV" b3="B70" />
      <ContingencyEquipment Action="X" Type="XF" b1="OCEANVIE" b2="230 KV" b3="BK 1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93580</SeqNum>
    <Name>230/35.Oceanview.T2</Name>
    <LastEdit Timestamp="2024-09-11T16:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANVIE" b2="230 KV" b3="B58" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANVIE" b2="230 KV" b3="B61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANVIE" b2="35 KV" b3="B72" />
      <ContingencyEquipment Action="X" Type="XF" b1="OCEANVIE" b2="230 KV" b3="BK 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93590</SeqNum>
    <Name>L115.Joppatown-RaphaelRoad + 230/115.RaphaelRoad.1</Name>
    <LastEdit Timestamp="2024-09-11T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOPPATOW" b2="115 KV" b3="620-624" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOPPATOW" b2="115 KV" b3="621-624" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOPPATOW" b2="115 KV" b3="JOP-RAP" />
      <ContingencyEquipment Action="X" Type="XF" b1="RAPHAERD" b2="230 KV" b3="230-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPHAERD" b2="230 KV" b3="2301_1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPHAERD" b2="230 KV" b3="2301_2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93600</SeqNum>
    <Name>L138.OpossumCreek-SLynchbu</Name>
    <LastEdit Timestamp="2024-09-11T16:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OPOSSUMC" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPOSSUMC" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="OPOSSUMC" b2="138 KV" b3="OPO-SLY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLYNCHBU" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93610</SeqNum>
    <Name>138/69.Roanoke.T5</Name>
    <LastEdit Timestamp="2025-03-27T17:51:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ROANOKE" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENINGTN" b2="138 KV" b3="BEN-ROAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMPBAVE" b2="69 KV" b3="CAM-ROA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ROANOKE" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLEARBRO" b2="138 KV" b3="CLE-ROA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRASSYHI" b2="138 KV" b3="GRA-ROA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOSELEY" b2="138 KV" b3="MOS-ROA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROANOKE" b2="138 KV" b3="ROA-SUN" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROANOKE" b2="69 KV" b3="ROA-WAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROANOKE" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="69 KV" b3="U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANOKE" b2="69 KV" b3="V" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93640</SeqNum>
    <Name>L138.NMuskingum-Philo</Name>
    <LastEdit Timestamp="2024-09-11T16:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="NMUSKING" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="NMUSKING" b2="138 KV" b3="NMU-PHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHILO" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93650</SeqNum>
    <Name>L138.Crooksville-Cannelsville-Philo</Name>
    <LastEdit Timestamp="2026-04-14T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CANNELVI" b2="138 KV" b3="CAN-PHI" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROOKSVI" b2="138 KV" b3="CRO-CAN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CANNELVI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROOKSVI" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHILO" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93690</SeqNum>
    <Name>L115.Pinewood-NorthDoswell.1013A</Name>
    <LastEdit Timestamp="2024-10-31T08:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NDOSWLDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEWOOD" b2="115 KV" b3="10081013" />
      <ContingencyEquipment Action="L" Type="LN" b1="NDOSWLDP" b2="115 KV" b3="1013A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEWOOD" b2="115 KV" b3="47T1013" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93700</SeqNum>
    <Name>230/115.Basin.TX6</Name>
    <LastEdit Timestamp="2024-10-18T13:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASIN" b2="230 KV" b3="H642" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASIN" b2="115 KV" b3="L642" />
      <ContingencyEquipment Action="X" Type="XF" b1="BASIN" b2="230 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93710</SeqNum>
    <Name>230/35.Basin.T3</Name>
    <LastEdit Timestamp="2025-02-24T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASIN" b2="230 KV" b3="H342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASIN" b2="35 KV" b3="L342" />
      <ContingencyEquipment Action="X" Type="XF" b1="BASIN" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BASIN" b2="35 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93720</SeqNum>
    <Name>230/35.Basin.T4</Name>
    <LastEdit Timestamp="2025-02-24T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASIN" b2="230 KV" b3="H442" />
      <ContingencyEquipment Action="X" Type="XF" b1="BASIN" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BASIN" b2="35 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93730</SeqNum>
    <Name>500/230.Brambleton.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRAMBLET" b2="500 KV" b3="H104M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="L102" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRAMBLET" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93740</SeqNum>
    <Name>500/230.Brambleton.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRAMBLET" b2="500 KV" b3="H204M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="L202" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRAMBLET" b2="500 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93750</SeqNum>
    <Name>230/115.EndlessCaverns.TX3 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ENDCAVRN" b2="230 KV" b3="H357M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="115 KV" b3="L352" />
      <ContingencyEquipment Action="X" Type="XF" b1="ENDCAVRN" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93760</SeqNum>
    <Name>230/115.EndlessCaverns.TX4 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ENDCAVRN" b2="230 KV" b3="H457M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="115 KV" b3="L452" />
      <ContingencyEquipment Action="X" Type="XF" b1="ENDCAVRN" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93770</SeqNum>
    <Name>230/115.EndlessCaverns.TX5 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-11-10T09:56:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ENDCAVRN" b2="230 KV" b3="H557" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="115 KV" b3="L552" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="115 KV" b3="L5T1083" />
      <ContingencyEquipment Action="X" Type="XF" b1="ENDCAVRN" b2="230 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93780</SeqNum>
    <Name>230/115.Everetts.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="EVERETTS" b2="230 KV" b3="H214M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERETTS" b2="115 KV" b3="L212" />
      <ContingencyEquipment Action="X" Type="XF" b1="EVERETTS" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93800</SeqNum>
    <Name>230/115.Gainesville.TX3 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GAINESVL" b2="230 KV" b3="H394" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAINESVL" b2="115 KV" b3="L392" />
      <ContingencyEquipment Action="X" Type="XF" b1="GAINESVL" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93810</SeqNum>
    <Name>L230.Loudoun-Gainesville.2030</Name>
    <LastEdit Timestamp="2024-09-12T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAINESVL" b2="230 KV" b3="20302151" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAINESVL" b2="230 KV" b3="203092" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOUDOUN4" b2="230 KV" b3="2030A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="20302117" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="203052" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93820</SeqNum>
    <Name>L230.Glebe-Crystal.275 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CRYSTAL4" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRYSTAL4" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRYSTAL4" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRYSTAL4" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GLEBE" b2="230 KV" b3="27596M" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRYSTAL4" b2="230 KV" b3="275A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93830</SeqNum>
    <Name>L230.Glebe-Crystal.276 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CRYSTAL4" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRYSTAL4" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CRYSTAL4" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRYSTAL4" b2="35 KV" b3="TX4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GLEBE" b2="230 KV" b3="27696M" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRYSTAL4" b2="230 KV" b3="276A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93840</SeqNum>
    <Name>230/115.Greenwich.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-04-24T14:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENWCH" b2="230 KV" b3="H154M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="115 KV" b3="L1T120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="115 KV" b3="L1T166" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENWCH" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93850</SeqNum>
    <Name>230/115.Greenwich.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-04-07T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GREENWCH" b2="230 KV" b3="H254M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="115 KV" b3="L2T120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWCH" b2="115 KV" b3="L2T67" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENWCH" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93860</SeqNum>
    <Name>230/115.Harrisonburg.TX6 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARRSNBG" b2="230 KV" b3="H694M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARRSNBG" b2="69 KV" b3="HEC6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="69 KV" b3="L692" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARRSNBG" b2="230 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93870</SeqNum>
    <Name>L115.KittyHawk-Colington.41</Name>
    <LastEdit Timestamp="2024-12-03T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="COLINGTN" b2="115 KV" b3="41T52-1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="COLINGTN" b2="115 KV" b3="SC3" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLINGTN" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COLINGTN" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KITTYHWK" b2="115 KV" b3="41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="115 KV" b3="4152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="115 KV" b3="L3T41" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93880</SeqNum>
    <Name>L138.LakeGeorge-Miller (NIPS)</Name>
    <LastEdit Timestamp="2024-09-11T16:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="17MILLER" b2="138 KV" b3="1722" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17MILLER" b2="138 KV" b3="22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="138 KV" b3="122" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEGEOR" b2="138 KV" b3="LAK-17M1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEGEOR" b2="138 KV" b3="X222" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93900</SeqNum>
    <Name>230/115.KittyHawk.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-30T16:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="115 KV" b3="L252" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="115 KV" b3="L2T52" />
      <ContingencyEquipment Action="X" Type="XF" b1="KITTYHWK" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93910</SeqNum>
    <Name>500/230.Ladysmith.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LADYSMTH" b2="500 KV" b3="H114M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMTH" b2="230 KV" b3="L1T2089" />
      <ContingencyEquipment Action="X" Type="XF" b1="LADYSMTH" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93920</SeqNum>
    <Name>230/115.Landstown.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-30T16:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LANDSTWN" b2="230 KV" b3="H154M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="115 KV" b3="L1T147" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LANDSTWN" b2="230 KV" b3="SC3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="230 KV" b3="SC352" />
      <ContingencyEquipment Action="X" Type="XF" b1="LANDSTWN" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93930</SeqNum>
    <Name>230/115.Landstown.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-30T16:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LANDSTWN" b2="230 KV" b3="H254M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="115 KV" b3="L2T147" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LANDSTWN" b2="230 KV" b3="SV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="230 KV" b3="SV152" />
      <ContingencyEquipment Action="X" Type="XF" b1="LANDSTWN" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93940</SeqNum>
    <Name>500/230.Midlothian.T6 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MIDLOTH" b2="500 KV" b3="H614M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLOTH" b2="230 KV" b3="L612" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDLOTH" b2="500 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93950</SeqNum>
    <Name>230/115.Northeast.TX9 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="NEAST" b2="230 KV" b3="H964M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="115 KV" b3="L962" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEAST" b2="230 KV" b3="TX9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93980</SeqNum>
    <Name>230/115.NorthernNeck.TX4 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-03-30T18:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="NRTHNECK" b2="230 KV" b3="H454M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="115 KV" b3="L4T1059" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="115 KV" b3="L4TGT" />
      <ContingencyEquipment Action="X" Type="XF" b1="NRTHNECK" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>93990</SeqNum>
    <Name>230/115.Peninsula.TX4</Name>
    <LastEdit Timestamp="2025-11-03T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENINSLA" b2="230 KV" b3="H402" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENINSLA" b2="115 KV" b3="L402" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENINSLA" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94010</SeqNum>
    <Name>230/115.RemingtonCT.TX9 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="REMNTNCT" b2="230 KV" b3="H964M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="115 KV" b3="L9T6" />
      <ContingencyEquipment Action="X" Type="XF" b1="REMNTNCT" b2="230 KV" b3="TX9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94020</SeqNum>
    <Name>230/115.SewellsPoint.TX5 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SEWELLPT" b2="230 KV" b3="H574M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWELLPT" b2="115 KV" b3="L572" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEWELLPT" b2="230 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94030</SeqNum>
    <Name>500/115.Spotsylvania.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-05-12T14:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SPOTSLV" b2="500 KV" b3="H174M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="115 KV" b3="L172" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPOTSLV" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94040</SeqNum>
    <Name>230/115.Suffolk.TX5 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-30T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUFFOLK" b2="230 KV" b3="H547M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="115 KV" b3="L1TL5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="115 KV" b3="L5T68" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUFFOLK" b2="230 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94050</SeqNum>
    <Name>500/230.Valley.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="VALLEY4" b2="500 KV" b3="H214M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEY4" b2="230 KV" b3="L212" />
      <ContingencyEquipment Action="X" Type="XF" b1="VALLEY4" b2="500 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94060</SeqNum>
    <Name>230/115.Whealton.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-11T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="WHEALTON" b2="230 KV" b3="H244M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEALTON" b2="115 KV" b3="L242" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHEALTON" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94070</SeqNum>
    <Name>230/115.Yadkin.TX3 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-12T11:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="YADKIN4" b2="230 KV" b3="H314M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="115 KV" b3="L3T46" />
      <ContingencyEquipment Action="X" Type="XF" b1="YADKIN4" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94080</SeqNum>
    <Name>500/230.Yadkin.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-12T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="YADKIN4" b2="500 KV" b3="H114M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="L112" />
      <ContingencyEquipment Action="X" Type="XF" b1="YADKIN4" b2="500 KV" b3="TX1P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94090</SeqNum>
    <Name>500/230.Yadkin.TX5 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-12T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="YADKIN4" b2="500 KV" b3="H514M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YADKIN4" b2="230 KV" b3="L512" />
      <ContingencyEquipment Action="X" Type="XF" b1="YADKIN4" b2="500 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94100</SeqNum>
    <Name>230/115.Yorktown.T9 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-12T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="YORKTOW4" b2="230 KV" b3="H984M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="115 KV" b3="L982-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="115 KV" b3="L982-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="YORKTOW4" b2="230 KV" b3="TX9" />
      <ContingencyEquipment Action="P" Type="XF" b1="YORKTOW4" b2="230 KV" b3="TX9PAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94120</SeqNum>
    <Name>L230.ETowanda-Hillside.2002 [NYISO]</Name>
    <LastEdit Timestamp="2025-11-03T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="230 KV" b3="B40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="230 KV" b3="B65" />
      <ContingencyEquipment Action="L" Type="LN" b1="ETOWANDA" b2="230 KV" b3="ETO-HIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSIDE" b2="230 KV" b3="7012" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94150</SeqNum>
    <Name>138/69.SouthMahwah.BK852</Name>
    <LastEdit Timestamp="2026-02-10T14:59:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RECOLVLD" b2="138 KV" b3="RECOBSLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="585-582Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="587-582Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="588-582Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="758-582Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="69 KV" b3="852-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMAWA" b2="138 KV" b3="852-A" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMAWA" b2="138 KV" b3="BK852" />
      <ContingencyEquipment Action="L" Type="LN" b1="RECOLVLD" b2="138 KV" b3="REC-SMA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94170</SeqNum>
    <Name>345/138.144Wayne.TR81</Name>
    <LastEdit Timestamp="2025-04-28T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="345 KV" b3="45TR81" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="144 WAYN" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="144 WAYN" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94180</SeqNum>
    <Name>345/138.144Wayne.TR84</Name>
    <LastEdit Timestamp="2025-03-27T15:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="345 KV" b3="45TR84" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="144 WAYN" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="144 WAYN" b2="138 KV" b3="TR84CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94190</SeqNum>
    <Name>L345.Wayne-14419-W407-Aurora.14419</Name>
    <LastEdit Timestamp="2025-03-27T17:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="144 WAYN" b2="345 KV" b3="14419 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="345 KV" b3="BT11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="144 WAYN" b2="345 KV" b3="BT12-16" />
      <ContingencyEquipment Action="L" Type="LN" b1="14419" b2="345 KV" b3="14419 1" />
      <ContingencyEquipment Action="S" Type="SD" b1="14419" b2="345 KV" b3="14419 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="14419" b2="345 KV" b3="14419 5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="951 AURO" b2="345 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="W407-6" b2="345 KV" b3="TR85A 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="W407-6" b2="345 KV" b3="TR85B 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="W407-6" b2="345 KV" b3="TR86 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="W407-6" b2="345 KV" b3="TR87 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="W407-6" b2="345 KV" b3="TR88 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94210</SeqNum>
    <Name>L345.Lordstown-Highland.1</Name>
    <LastEdit Timestamp="2024-10-14T11:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="124" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="128" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORDSTWN" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORDSTWN" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLAOE" b2="345 KV" b3="HIG-LOR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94220</SeqNum>
    <Name>L345.Lordstown-Highland.2</Name>
    <LastEdit Timestamp="2024-10-14T11:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORDSTWN" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORDSTWN" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLAOE" b2="345 KV" b3="HIG-LOR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94230</SeqNum>
    <Name>L345.Lordstown-Wellsville</Name>
    <LastEdit Timestamp="2025-03-24T11:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LORDSTWN" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORDSTWN" b2="345 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="LORDSTWN" b2="345 KV" b3="LOR-WELL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLSVIL" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLSVIL" b2="345 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94240</SeqNum>
    <Name>L345.Lordstown-Mansfield</Name>
    <LastEdit Timestamp="2024-10-14T11:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LORDSTWN" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORDSTWN" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="LORDSTWN" b2="345 KV" b3="LOR-MAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="B151" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="B154" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94250</SeqNum>
    <Name>L345.Lordstown-LordstownEC</Name>
    <LastEdit Timestamp="2024-10-14T13:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LORDSTWN" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LORDSTWN" b2="345 KV" b3="B6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LRDTWNEC" b2="19 KV" b3="AUX11" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LRDTWNEC" b2="19 KV" b3="AUX12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LRDTWNEC" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LRDTWNEC" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LRDTWNEC" b2="19 KV" b3="CT11" />
      <ContingencyEquipment Action="X" Type="XF" b1="LRDTWNEC" b2="345 KV" b3="CT11GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LRDTWNEC" b2="19 KV" b3="CT12" />
      <ContingencyEquipment Action="X" Type="XF" b1="LRDTWNEC" b2="345 KV" b3="CT12GSU" />
      <ContingencyEquipment Action="L" Type="LN" b1="LORDSTWN" b2="345 KV" b3="LOR-LOR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LRDTWNEC" b2="19 KV" b3="ST10" />
      <ContingencyEquipment Action="X" Type="XF" b1="LRDTWNEC" b2="345 KV" b3="ST10GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94270</SeqNum>
    <Name>L138.Tiffany-PentagonEnergy-Thompson</Name>
    <LastEdit Timestamp="2025-10-10T13:41:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PTGENRGY" b2="115 KV" b3="LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="PTGENRGY" b2="115 KV" b3="PTG-THO" />
      <ContingencyEquipment Action="L" Type="LN" b1="PTGENRGY" b2="115 KV" b3="PTG-TIF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THOMPSON" b2="115 KV" b3="1 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFANY" b2="115 KV" b3="B19" />
      <ContingencyEquipment Action="L" Type="LN" b1="THOMPSON" b2="115 KV" b3="THO-TIF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94280</SeqNum>
    <Name>L345.MeadowLake-Reynolds.2</Name>
    <LastEdit Timestamp="2026-05-08T11:45:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWLK" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWLK" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADOWLK" b2="345 KV" b3="MEA-REY2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="30-XF3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="34530" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94290</SeqNum>
    <Name>L345.OraOra-Reynolds</Name>
    <LastEdit Timestamp="2024-09-03T14:52:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ORAORA" b2="345 KV" b3="M007A8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORAORA" b2="345 KV" b3="M007B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ORAORA" b2="345 KV" b3="ORA-REYN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="34527" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="34527-00" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94300</SeqNum>
    <Name>345/138.Reynolds.T1 (NIPS)</Name>
    <LastEdit Timestamp="2026-05-08T11:46:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="REYNOLD2" b2="345 KV" b3=".  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="43-XFR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="XFR1CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94320</SeqNum>
    <Name>138/34.Fieldale.T1</Name>
    <LastEdit Timestamp="2025-05-05T11:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FIELDALE" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FIELDALE" b2="34 KV" b3="CAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FIELDALE" b2="34 KV" b3="CAE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDALE" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94340</SeqNum>
    <Name>OpossumCreek.SC2</Name>
    <LastEdit Timestamp="2024-12-06T10:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OPOSSUMC" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPOSSUMC" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="X" Type="XF" b1="OPOSSUMC" b2="138 KV" b3="GSU2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OPOSSUMC" b2="13.8 KV" b3="SC2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94370</SeqNum>
    <Name>230/13.Emilie.T2</Name>
    <LastEdit Timestamp="2024-08-27T09:40:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="230 KV" b3="25_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="EMILIE" b2="230 KV" b3="EMIL2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94380</SeqNum>
    <Name>230/13.Peltz.T6</Name>
    <LastEdit Timestamp="2025-09-05T11:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PELTZ" b2="230 KV" b3="6 TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PELTZ" b2="13 KV" b3="65 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PELTZ" b2="230 KV" b3="955" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PELTZ" b2="230 KV" b3="975" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94390</SeqNum>
    <Name>230/13.Richmond.T90</Name>
    <LastEdit Timestamp="2024-09-12T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="230 KV" b3="185 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="230 KV" b3="415 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="13 KV" b3="91 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="13 KV" b3="92 CT CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="RICH PE" b2="230 KV" b3="RICH 90" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RICH PE" b2="13 KV" b3="UNIT91" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RICH PE" b2="13 KV" b3="UNIT92" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94400</SeqNum>
    <Name>230/13.HinchmansAve.T20</Name>
    <LastEdit Timestamp="2025-06-27T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HINCHMAN" b2="230 KV" b3="T20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINCHMAN" b2="230 KV" b3="T20HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINCHMAN" b2="13 KV" b3="T20LS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HINCHMAN" b2="13 KV" b3="TRANSF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94410</SeqNum>
    <Name>230/69.Brunswick.220-5XF</Name>
    <LastEdit Timestamp="2025-03-26T10:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="69 KV" b3="2-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNSWIC" b2="230 KV" b3="220-5 XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="69 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SEC11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SECT3-11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94420</SeqNum>
    <Name>115/35.Earleys.TX2</Name>
    <LastEdit Timestamp="2024-09-16T10:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="115 KV" b3="13662" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="115 KV" b3="5462" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="115 KV" b3="L362" />
      <ContingencyEquipment Action="X" Type="XF" b1="EARLEYS" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EARLEYS" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="EARLEYS" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94430</SeqNum>
    <Name>230/26.SouthWaterFront.T1</Name>
    <LastEdit Timestamp="2025-01-10T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="230 KV" b3="220-1CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWATERFR" b2="26 KV" b3="220-1LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="26 KV" b3="LDTRANSF" />
      <ContingencyEquipment Action="X" Type="XF" b1="SWATERFR" b2="230 KV" b3="T220-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94440</SeqNum>
    <Name>230/26.SouthWaterFront.T2</Name>
    <LastEdit Timestamp="2025-01-10T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="230 KV" b3="220-2CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWATERFR" b2="26 KV" b3="220-2LD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SWATERFR" b2="26 KV" b3="26 CAPA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SWATERFR" b2="26 KV" b3="26 CAPB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="26 KV" b3="CAP1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="26 KV" b3="LDTRANSF" />
      <ContingencyEquipment Action="X" Type="XF" b1="SWATERFR" b2="230 KV" b3="T220-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94450</SeqNum>
    <Name>230/26.SouthWaterFront.T3</Name>
    <LastEdit Timestamp="2025-01-10T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWATERFR" b2="26 KV" b3="220_3LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="26 KV" b3="LD34TRAN" />
      <ContingencyEquipment Action="X" Type="XF" b1="SWATERFR" b2="230 KV" b3="T220-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="230 KV" b3="TRAN3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94460</SeqNum>
    <Name>230/26.SouthWaterFront.T4</Name>
    <LastEdit Timestamp="2025-01-10T11:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWATERFR" b2="26 KV" b3="220_4LD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SWATERFR" b2="26 KV" b3="26 CAPC" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SWATERFR" b2="26 KV" b3="26 CAPD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="26 KV" b3="CAP2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="26 KV" b3="LD34TRAN" />
      <ContingencyEquipment Action="X" Type="XF" b1="SWATERFR" b2="230 KV" b3="T220-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWATERFR" b2="230 KV" b3="TRAN4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94470</SeqNum>
    <Name>230/26.ToscoGIS.TR1</Name>
    <LastEdit Timestamp="2025-06-12T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOGIS" b2="230 KV" b3="230-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOGIS" b2="230 KV" b3="230-5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TOSCOGIS" b2="27 KV" b3="DUM20077" />
      <ContingencyEquipment Action="X" Type="XF" b1="TOSCOGIS" b2="230 KV" b3="TR-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94480</SeqNum>
    <Name>230/26.ToscoGIS.TR2</Name>
    <LastEdit Timestamp="2025-06-12T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOGIS" b2="230 KV" b3="230-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOGIS" b2="230 KV" b3="230-7" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TOSCOGIS" b2="27 KV" b3="DUM20079" />
      <ContingencyEquipment Action="X" Type="XF" b1="TOSCOGIS" b2="230 KV" b3="TR-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94490</SeqNum>
    <Name>230/26.ToscoGIS.TR3</Name>
    <LastEdit Timestamp="2025-06-12T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOGIS" b2="230 KV" b3="230-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOGIS" b2="230 KV" b3="230-9" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TOSCOGIS" b2="27 KV" b3="DUM20081" />
      <ContingencyEquipment Action="X" Type="XF" b1="TOSCOGIS" b2="230 KV" b3="TR-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94500</SeqNum>
    <Name>Tosco.U1</Name>
    <LastEdit Timestamp="2025-06-20T15:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOGIS" b2="230 KV" b3="230-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOSCOGIS" b2="230 KV" b3="230-6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TOSCOGIS" b2="18 KV" b3="TOSCO1" />
      <ContingencyEquipment Action="X" Type="XF" b1="TOSCOGIS" b2="230 KV" b3="TR-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94510</SeqNum>
    <Name>230/69.Burlington.220-6</Name>
    <LastEdit Timestamp="2024-10-30T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="69 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="1-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="X" Type="XF" b1="BURLINGT" b2="230 KV" b3="220-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="69 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94520</SeqNum>
    <Name>230/35.Montville.1TR</Name>
    <LastEdit Timestamp="2025-06-12T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTVILL" b2="230 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTVILL" b2="230 KV" b3="B9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTVILL" b2="35 KV" b3="BK 1LCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MONTVILL" b2="230 KV" b3="BK 1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94530</SeqNum>
    <Name>230/35.Montville.2TR</Name>
    <LastEdit Timestamp="2025-06-12T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTVILL" b2="230 KV" b3="B125" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTVILL" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTVILL" b2="230 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTVILL" b2="35 KV" b3="BK 2LCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MONTVILL" b2="230 KV" b3="BK 2TR" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MONTVILL" b2="230 KV" b3="CAP3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94540</SeqNum>
    <Name>230/69.SouthLebanon.T1</Name>
    <LastEdit Timestamp="2025-05-30T09:57:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SLEBANON" b2="230 KV" b3="1BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLEBANON" b2="69 KV" b3="B120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLEBANON" b2="230 KV" b3="B60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLEBANON" b2="230 KV" b3="B70" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94550</SeqNum>
    <Name>230/69.SouthReading.T7</Name>
    <LastEdit Timestamp="2024-10-23T10:31:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SREADING" b2="230 KV" b3="7 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SREADING" b2="69 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SREADING" b2="69 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SREADING" b2="230 KV" b3="B752" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94610</SeqNum>
    <Name>138/69/34.SLynchburg.T1</Name>
    <LastEdit Timestamp="2025-07-11T13:58:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SLYNCHBU" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SLYNCHBU" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SLYNCHBU" b2="34 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLYNCHBU" b2="34 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLYNCHBU" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SLYNCHBU" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94630</SeqNum>
    <Name>L138.Amlin-Sumac.1</Name>
    <LastEdit Timestamp="2025-08-01T13:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMLIN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMLIN" b2="138 KV" b3="DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMLIN" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMLIN" b2="138 KV" b3="AML-SUM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMAC" b2="138 KV" b3="BA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMAC" b2="138 KV" b3="BC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94640</SeqNum>
    <Name>L138.Amlin-Sumac.2</Name>
    <LastEdit Timestamp="2024-09-12T11:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMLIN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMLIN" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMLIN" b2="138 KV" b3="AML-SUM2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMAC" b2="138 KV" b3="BD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMAC" b2="138 KV" b3="BF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94700</SeqNum>
    <Name>L138.EastElkhart-RVCapital-Mottville</Name>
    <LastEdit Timestamp="2024-08-15T16:43:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTTVILL" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="EELKHART" b2="138 KV" b3="EEL-RVCA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RVCAPITA" b2="138 KV" b3="M00179" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOTTVILL" b2="138 KV" b3="MOT-RVCA" />
      <ContingencyEquipment Action="S" Type="SD" b1="RVCAPITA" b2="138 KV" b3="RVCAPTAP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RVCAPITA" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94730</SeqNum>
    <Name>L345.Garver-Middletown + Middletown.CC</Name>
    <LastEdit Timestamp="2025-03-14T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="345 KV" b3="1433" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="345 KV" b3="1435" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARVER" b2="345 KV" b3="GAR-MDL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLTWN2" b2="345 KV" b3="CTG_HV" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDLTWN2" b2="345 KV" b3="GSU1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDLTWN2" b2="345 KV" b3="GSU2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDLTWN2" b2="21 KV" b3="LOAD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MIDLTWN2" b2="21 KV" b3="MIDDLTCT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MIDLTWN2" b2="18 KV" b3="MIDDLTST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLTWN2" b2="345 KV" b3="STG_HV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94750</SeqNum>
    <Name>L138.Brookside-Madison</Name>
    <LastEdit Timestamp="2025-01-16T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKSID" b2="138 KV" b3="A82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSID" b2="138 KV" b3="B135" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKSID" b2="138 KV" b3="BRO-MAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISOE" b2="138 KV" b3="B56" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISOE" b2="138 KV" b3="B57" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94760</SeqNum>
    <Name>L138.Longview-Madison</Name>
    <LastEdit Timestamp="2024-09-12T13:35:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONGVIOE" b2="138 KV" b3="A115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGVIOE" b2="138 KV" b3="B171" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONGVIOE" b2="138 KV" b3="LON-MAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISOE" b2="138 KV" b3="B55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISOE" b2="138 KV" b3="B56" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94770</SeqNum>
    <Name>L138.Ryan-Seville</Name>
    <LastEdit Timestamp="2025-05-20T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RYAN" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RYAN" b2="138 KV" b3="B61" />
      <ContingencyEquipment Action="L" Type="LN" b1="RYAN" b2="138 KV" b3="RYA-SEV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEVILL" b2="138 KV" b3="B6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94780</SeqNum>
    <Name>L138.WestMedina-Ryan</Name>
    <LastEdit Timestamp="2025-05-16T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RYAN" b2="138 KV" b3="B60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RYAN" b2="138 KV" b3="B61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMEDINA" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="L" Type="LN" b1="WMEDINA" b2="138 KV" b3="WME-RYA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94790</SeqNum>
    <Name>L138.Galion-OntarioStumboTP-Ontario</Name>
    <LastEdit Timestamp="2026-02-18T10:13:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="54" />
      <ContingencyEquipment Action="L" Type="LN" b1="GALION" b2="138 KV" b3="GAL-ONTS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONTARIOE" b2="138 KV" b3="B111" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONTARIOE" b2="138 KV" b3="B114" />
      <ContingencyEquipment Action="L" Type="LN" b1="ONTARIOE" b2="138 KV" b3="ONT-ONTS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ONTARIST" b2="138 KV" b3="ONTASTUM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94840</SeqNum>
    <Name>L115.Suffolk-OakRidge-Myrtle-WindsorDP-BellAve.44</Name>
    <LastEdit Timestamp="2024-07-16T12:50:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLAVE" b2="115 KV" b3="15T44" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELLAVE" b2="115 KV" b3="4495" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLAVE" b2="115 KV" b3="44A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MYRTLE" b2="115 KV" b3="44C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MYRTLE" b2="115 KV" b3="H162" />
      <ContingencyEquipment Action="X" Type="XF" b1="MYRTLE" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MYRTLE" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OAKRIDGE" b2="115 KV" b3="4437" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="115 KV" b3="23T44" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUFFOLK" b2="115 KV" b3="44D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="115 KV" b3="L1T44" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SUFFOLK" b2="115 KV" b3="SC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUFFOLK" b2="115 KV" b3="SC142" />
      <ContingencyEquipment Action="L" Type="LN" b1="WINDSRDP" b2="115 KV" b3="44B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WINDSRDP" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94850</SeqNum>
    <Name>138/69.Magley.T1</Name>
    <LastEdit Timestamp="2024-09-12T11:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MAGLEY" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGLEY" b2="69 KV" b3="XB1L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGLEY" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94860</SeqNum>
    <Name>L138.Zodiac-Magley</Name>
    <LastEdit Timestamp="2026-03-04T10:36:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGLEY" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAGLEY" b2="138 KV" b3="MAG-ZODI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008N5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008N8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94890</SeqNum>
    <Name>138/69.Adams.T1</Name>
    <LastEdit Timestamp="2024-09-13T09:56:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSAEP" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSAEP" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ADAMSAEP" b2="69 KV" b3="CAP AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSAEP" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADAMSAEP" b2="69 KV" b3="F2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ADAMSAEP" b2="138 KV" b3="TF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94920</SeqNum>
    <Name>138/69.Huntley.T3&amp;T4</Name>
    <LastEdit Timestamp="2025-01-09T14:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTLEY2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTLEY2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="GESUPER" b2="138 KV" b3="GES-HUN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUNTLEY2" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUNTLEY2" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94930</SeqNum>
    <Name>138/69.WestLancaster.T2</Name>
    <LastEdit Timestamp="2024-09-12T13:38:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WLANCAST" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLANCAST" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLANCAST" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLANCAST" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WLANCAST" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94940</SeqNum>
    <Name>138/69/12.EastDanville.T1</Name>
    <LastEdit Timestamp="2025-05-12T16:00:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EDANVILL" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDANVILL" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDANVILL" b2="12 KV" b3="1-T" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDANVILL" b2="230 KV" b3="5" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="EDANVILL" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDANVILL" b2="12 KV" b3="DIBRELL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDANVILL" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDANVILL" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDANVILL" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDANVILL" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDANVILL" b2="230 KV" b3="T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94960</SeqNum>
    <Name>138/69/46.BeaverCreek.T2</Name>
    <LastEdit Timestamp="2025-11-13T09:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BEAVERCR" b2="138 KV" b3="2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAVERCR" b2="69 KV" b3="2-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAVERCR" b2="46 KV" b3="2-T" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BEAVERCR" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="46 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="138 KV" b3="S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94970</SeqNum>
    <Name>L345.Lisle-Lockport.10801</Name>
    <LastEdit Timestamp="2025-01-27T14:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="103 LISL" b2="345 KV" b3="10801" />
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="345 KV" b3="L10801CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT3-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="108 LOCK" b2="345 KV" b3="BT9-10CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>94990</SeqNum>
    <Name>138/69/46.BeaverCreek.T1</Name>
    <LastEdit Timestamp="2024-11-13T14:47:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BEAVERCR" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAVERCR" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEAVERCR" b2="46 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="46 KV" b3="B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BEAVERCR" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BEAVERCR" b2="69 KV" b3="T1E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95010</SeqNum>
    <Name>138/69/34.Bellefonte.T2</Name>
    <LastEdit Timestamp="2025-11-17T11:52:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEFON" b2="69 KV" b3="T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELLEFON" b2="138 KV" b3="T6" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLEFON" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEFON" b2="138 KV" b3="W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEFON" b2="138 KV" b3="X" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEFON" b2="138 KV" b3="Y" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95030</SeqNum>
    <Name>138/69.Carrollton.T3</Name>
    <LastEdit Timestamp="2024-09-12T13:35:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARROLLT" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARROLLT" b2="138 KV" b3="XF-T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARROLLT" b2="138 KV" b3="XT3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95040</SeqNum>
    <Name>138/69.Crooksville.T1</Name>
    <LastEdit Timestamp="2025-09-12T11:14:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROOKSVI" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROOKSVI" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROOKSVI" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROOKSVI" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROOKSVI" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROOKSVI" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95050</SeqNum>
    <Name>138/69.Gavin.T1</Name>
    <LastEdit Timestamp="2025-06-18T12:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="GAVINAEP" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="69 KV" b3="E2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAVINAEP" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95080</SeqNum>
    <Name>138/69.Hazard.T2</Name>
    <LastEdit Timestamp="2026-01-28T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HAZARD" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZARD" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZARD" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95110</SeqNum>
    <Name>230/115.Earleys.TX4</Name>
    <LastEdit Timestamp="2024-09-12T11:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="H462" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="115 KV" b3="L462" />
      <ContingencyEquipment Action="X" Type="XF" b1="EARLEYS" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95190</SeqNum>
    <Name>L138.MuskingumRiver-NMuskingum-Philo</Name>
    <LastEdit Timestamp="2024-10-31T08:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="138 KV" b3="HC" />
      <ContingencyEquipment Action="L" Type="LN" b1="MUSKING2" b2="138 KV" b3="MUS-NMU1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NMUSKING" b2="138 KV" b3="NMU-PHI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NMUSKING" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMUSKING" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHILO" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95210</SeqNum>
    <Name>138/69.Danville.T1</Name>
    <LastEdit Timestamp="2026-04-14T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DANVILLE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANVILLE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANVILLE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DANVILLE" b2="138 KV" b3="CAPB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANVILLE" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANVILLE" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="X" Type="XF" b1="DANVILLE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95240</SeqNum>
    <Name>138/69.Millbrook.T5</Name>
    <LastEdit Timestamp="2026-05-08T15:12:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLBROO" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLBROO" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLBROO" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLBROO" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLBROO" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MILLBROO" b2="69 KV" b3="T" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILLBROO" b2="138 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95250</SeqNum>
    <Name>138/69.Milton.T3</Name>
    <LastEdit Timestamp="2024-09-12T13:40:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON2" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILTON2" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILTON2" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON2" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95260</SeqNum>
    <Name>138/69.Sawmill.T1&amp;T4</Name>
    <LastEdit Timestamp="2024-09-12T11:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="101N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="103N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="105N" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SAWMILL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SAWMILL" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95270</SeqNum>
    <Name>138/69.Selmapar.T2</Name>
    <LastEdit Timestamp="2024-09-12T11:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SELMAPAR" b2="138 KV" b3="A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SELMAPAR" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SELMAPAR" b2="69 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95290</SeqNum>
    <Name>138/69.Bradley.T1</Name>
    <LastEdit Timestamp="2025-01-28T17:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BRADLEY" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRADLEY" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRADLEY" b2="46 KV" b3="1-T" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADLEY" b2="69 KV" b3="BRA-PRI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADLEY" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADLEY" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BRADLEY" b2="46 KV" b3="RALEIGLF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRADLEY" b2="46 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95300</SeqNum>
    <Name>138/69.BiersRun.TX3</Name>
    <LastEdit Timestamp="2024-09-12T11:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="69 KV" b3="K1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BIERSRUN" b2="138 KV" b3="XF3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95310</SeqNum>
    <Name>L345.Elderberry-StJosephEnergyCenter</Name>
    <LastEdit Timestamp="2024-09-12T13:34:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDERBER" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDERBER" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SJEC" b2="345 KV" b3="1A" />
      <ContingencyEquipment Action="X" Type="XF" b1="SJEC" b2="345 KV" b3="1B" />
      <ContingencyEquipment Action="X" Type="XF" b1="SJEC" b2="345 KV" b3="1S" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SJEC" b2="18 KV" b3="CTG1A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SJEC" b2="18 KV" b3="CTG1B" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELDERBER" b2="345 KV" b3="ELD-SJE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SJEC" b2="345 KV" b3="SJEC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SJEC" b2="18 KV" b3="SS1A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SJEC" b2="18 KV" b3="SS1B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SJEC" b2="18 KV" b3="STG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95320</SeqNum>
    <Name>L138.WestEndFostoria-Stiffin-Melmore</Name>
    <LastEdit Timestamp="2025-11-03T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MELMORE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELMORE" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MELMORE" b2="138 KV" b3="MEL-STI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STIFFIN" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEFOSTOR" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="STIFFIN" b2="138 KV" b3="STI-WEF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95330</SeqNum>
    <Name>138/69.MollysCreek.T1</Name>
    <LastEdit Timestamp="2025-05-12T16:09:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOLLYCRK" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOLLYCRK" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOLLYCRK" b2="69 KV" b3="MOL-THUR" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOLLYCRK" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOLLYCRK" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95340</SeqNum>
    <Name>138/69.Darrah.T2</Name>
    <LastEdit Timestamp="2025-12-26T13:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DARRAH" b2="138 KV" b3="2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="DARRAH" b2="69 KV" b3="2-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="DARRAH" b2="34 KV" b3="2-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARRAH" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DARRAH" b2="34 KV" b3="INCOMIL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARRAH" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95370</SeqNum>
    <Name>138/69/12.Halesbranch.T1</Name>
    <LastEdit Timestamp="2026-05-08T15:03:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HALESBRA" b2="69 KV" b3="A008T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HALESBRA" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HALESBRA" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HALESBRA" b2="12 KV" b3="LOAD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HALESBRA" b2="138 KV" b3="P-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HALESBRA" b2="69 KV" b3="S-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HALESBRA" b2="69 KV" b3="SMOKELES" />
      <ContingencyEquipment Action="X" Type="XF" b1="HALESBRA" b2="12 KV" b3="T-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HALESBRA" b2="138 KV" b3="XT1 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95380</SeqNum>
    <Name>138/69.NorthNewark.T1</Name>
    <LastEdit Timestamp="2025-10-10T12:23:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NNEWARK" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NNEWARK" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NNEWARK" b2="138 KV" b3="H001A8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NNEWARK" b2="138 KV" b3="I" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NNEWARK" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NNEWARK" b2="138 KV" b3="T5" />
      <ContingencyEquipment Action="X" Type="XF" b1="NNEWARK" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>95390</SeqNum>
    <Name>138/69.NorthNewark.T2</Name>
    <LastEdit Timestamp="2025-10-10T12:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NNEWARK" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NNEWARK" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NNEWARK" b2="138 KV" b3="H000Z8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NNEWARK" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="X" Type="XF" b1="NNEWARK" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96020</SeqNum>
    <Name>L345.MeadowLake-Reynolds.1</Name>
    <LastEdit Timestamp="2025-08-01T13:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWLK" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWLK" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADOWLK" b2="345 KV" b3="MEA-REY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="34531" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="34531-32" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96140</SeqNum>
    <Name>L138.KingsCreek-PerryRd(SolarFarm)</Name>
    <LastEdit Timestamp="2025-04-10T15:53:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="138" />
      <ContingencyEquipment Action="X" Type="XF" b1="KINGSCRK" b2="138 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="GSU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="GSU2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KINGSCRK" b2="34.5 KV" b3="PERRY1SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KINGSCRK" b2="34.5 KV" b3="PERRY2SP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96230</SeqNum>
    <Name>L138.Marktown-Inland Steel 5</Name>
    <LastEdit Timestamp="2025-03-04T10:28:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="17MRKTWN" b2="138 KV" b3="17M-INL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17MRKTWN" b2="138 KV" b3="30N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17MRKTWN" b2="138 KV" b3="30S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND5T" b2="138 KV" b3="3830" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96240</SeqNum>
    <Name>L138.BluffPoint-Jay</Name>
    <LastEdit Timestamp="2025-08-04T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUFFPOI" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUFFPOI" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUFFPOI" b2="138 KV" b3="BLU-JAY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JAY" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JAY" b2="138 KV" b3="D2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96250</SeqNum>
    <Name>L138.Azalea-Leesville</Name>
    <LastEdit Timestamp="2024-09-12T11:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AZALEA" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="AZALEA" b2="138 KV" b3="AZA-LEE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AZALEA" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESVIL2" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96320</SeqNum>
    <Name>L115.Newsoms-Boykins.1017</Name>
    <LastEdit Timestamp="2024-09-12T13:35:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOYKINS" b2="115 KV" b3="101732" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWSOMS" b2="115 KV" b3="101792" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOYKINS" b2="115 KV" b3="1017A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWSOMS" b2="115 KV" b3="140T1017" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96330</SeqNum>
    <Name>KeysEnergy.CC (Cheltenham)</Name>
    <LastEdit Timestamp="2024-09-12T13:37:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHELTENH" b2="500 KV" b3="1BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHELTENH" b2="500 KV" b3="1CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHELTENH" b2="18 KV" b3="AUXTR11" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHELTENH" b2="18 KV" b3="AUXTR12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHELTENH" b2="18 KV" b3="CTG11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHELTENH" b2="18 KV" b3="CTG12" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHELTENH" b2="500 KV" b3="GSU10TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHELTENH" b2="500 KV" b3="GSU11TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHELTENH" b2="500 KV" b3="GSU12TR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHELTENH" b2="19 KV" b3="STG10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96350</SeqNum>
    <Name>L69.Schuylkill-Lombard.6633</Name>
    <LastEdit Timestamp="2024-09-12T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOMBARD" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOMBARD" b2="13 KV" b3="5TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOMBARD" b2="69 KV" b3="LOM 4TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOMBARD" b2="69 KV" b3="LOM 5TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOMBARD" b2="69 KV" b3="LOM-SCH3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="150 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHUYLKI" b2="69 KV" b3="160 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96390</SeqNum>
    <Name>L345.MeadowLake4-MeadowLake6</Name>
    <LastEdit Timestamp="2025-10-17T12:19:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWL4" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWL4" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADOWL4" b2="345 KV" b3="MEA-MEA6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWL6" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MEADOWL6" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEADOWL6" b2="345 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEADOWL6" b2="34.5 KV" b3="MEDLK6WF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96400</SeqNum>
    <Name>MeadowLake.WF6</Name>
    <LastEdit Timestamp="2025-05-05T13:05:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWL6" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MEADOWL6" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEADOWL6" b2="345 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEADOWL6" b2="34.5 KV" b3="MEDLK6WF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96420</SeqNum>
    <Name>L138.Lunenburg-GaryDP-Kenbridge</Name>
    <LastEdit Timestamp="2025-03-24T11:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="GARYDP" b2="115 KV" b3="1023CSD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GARYDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARYDP" b2="115 KV" b3="1023B" />
      <ContingencyEquipment Action="X" Type="XF" b1="KENBRIDG" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KENBRIDG" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUNENBRG" b2="115 KV" b3="10231034" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARYDP" b2="115 KV" b3="1023A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUNENBRG" b2="115 KV" b3="98T1023" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96430</SeqNum>
    <Name>69/13.Huntsville.T2</Name>
    <LastEdit Timestamp="2025-04-08T10:03:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTSVIL" b2="69 KV" b3="66155" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTSVIL" b2="69 KV" b3="6670" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTSVIL" b2="13 KV" b3="750" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUNTSVIL" b2="13 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUNTSVIL" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96440</SeqNum>
    <Name>69/13.Huntsville.T1</Name>
    <LastEdit Timestamp="2025-06-18T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTSVIL" b2="13 KV" b3="245" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTSVIL" b2="69 KV" b3="66145" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTSVIL" b2="69 KV" b3="6670" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUNTSVIL" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96450</SeqNum>
    <Name>345/138.Bunsonville.TR1</Name>
    <LastEdit Timestamp="2024-09-13T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUNSONV3" b2="138 KV" b3="1576" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUNSONV3" b2="345 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUNSONV3" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUNSONV3" b2="345 KV" b3="V11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96460</SeqNum>
    <Name>345/138.Newton.T2(Ameren)</Name>
    <LastEdit Timestamp="2024-09-13T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTON 3" b2="138 KV" b3="1856" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTON 3" b2="138 KV" b3="1868" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTON 3" b2="345 KV" b3="3490" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWTON 3" b2="345 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96470</SeqNum>
    <Name>L345.Cayuga-Nucor (CIN)</Name>
    <LastEdit Timestamp="2024-09-13T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="345 KV" b3="01B9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="345 KV" b3="10-01" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NUCOR" b2="345 KV" b3="01" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NUCOR" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NUCOR" b2="345 KV" b3="NUC-CAY1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96480</SeqNum>
    <Name>138/69.Yager.TX1</Name>
    <LastEdit Timestamp="2024-09-13T09:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="69 KV" b3="F3 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="YAGER" b2="138 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96490</SeqNum>
    <Name>L230.Nottingham-Colora.220-01</Name>
    <LastEdit Timestamp="2025-08-26T17:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLORA" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLORA" b2="230 KV" b3="236" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTTINGH" b2="230 KV" b3="015" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLORA" b2="230 KV" b3="COL-NOTT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96500</SeqNum>
    <Name>L115.LonePine-Crewe-Martin-Victoria-Lunenburg.1034</Name>
    <LastEdit Timestamp="2025-07-29T12:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CREWE" b2="115 KV" b3="1034G" />
      <ContingencyEquipment Action="X" Type="XF" b1="CREWE" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CREWE" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONEPINE" b2="115 KV" b3="10071034" />
      <ContingencyEquipment Action="L" Type="LN" b1="CREWE" b2="115 KV" b3="1034E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONEPINE" b2="115 KV" b3="1T1034" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUNENBRG" b2="115 KV" b3="10051034" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUNENBRG" b2="115 KV" b3="10231034" />
      <ContingencyEquipment Action="L" Type="LN" b1="LUNENBRG" b2="115 KV" b3="1034A" />
      <ContingencyEquipment Action="S" Type="SD" b1="MARTINDP" b2="115 KV" b3="1034SD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARTINDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="VICTORDP" b2="115 KV" b3="1034C" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARTINDP" b2="115 KV" b3="1034D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VICTORDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VICTORIA" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96510</SeqNum>
    <Name>L115.Lunenburg-NutBushDP.1005</Name>
    <LastEdit Timestamp="2024-09-13T09:48:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LUNENBRG" b2="115 KV" b3="10051034" />
      <ContingencyEquipment Action="L" Type="LN" b1="LUNENBRG" b2="115 KV" b3="1005A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUNENBRG" b2="115 KV" b3="98T1005" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NUTBSHDP" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96520</SeqNum>
    <Name>L138.SouthCadiz-GableSW</Name>
    <LastEdit Timestamp="2024-09-13T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GABLESW" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="GABLESW" b2="138 KV" b3="GAB-SCA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCADIZ" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCADIZ" b2="138 KV" b3="H1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96530</SeqNum>
    <Name>L138.GableSW-Carrollton</Name>
    <LastEdit Timestamp="2024-09-12T13:36:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARROLLT" b2="138 KV" b3="CAR-GAB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARROLLT" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GABLESW" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96540</SeqNum>
    <Name>L138.SouthCadiz-Freebyrd</Name>
    <LastEdit Timestamp="2024-09-12T14:43:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FREEBYRD" b2="138 KV" b3="FRE-SCAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEBYRD" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEBYRD" b2="138 KV" b3="R1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCADIZ" b2="138 KV" b3="F CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCADIZ" b2="138 KV" b3="F1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96560</SeqNum>
    <Name>Newsoms.SP</Name>
    <LastEdit Timestamp="2026-01-09T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWSOMS" b2="115 KV" b3="GENCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWSOMS" b2="34.5 KV" b3="NEWSOMSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96650</SeqNum>
    <Name>L345.Chestnut-Latham.9503</Name>
    <LastEdit Timestamp="2026-01-02T11:04:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="95 CHEST" b2="345 KV" b3="9503" />
      <ContingencyEquipment Action="OP" Type="CB" b1="95 CHEST" b2="345 KV" b3="BT1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="95 CHEST" b2="345 KV" b3="BT2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LATHAM" b2="345 KV" b3="V15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LATHAM" b2="345 KV" b3="V17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96660</SeqNum>
    <Name>L345.Chestnut-TwinForks.93301 + TwinFork.WF</Name>
    <LastEdit Timestamp="2025-07-29T12:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="933 TWIN" b2="34.5 KV" b3="GEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="933 TWIN" b2="345 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="933 TWIN" b2="345 KV" b3="H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="933 TWIN" b2="345 KV" b3="H3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="933 TWIN" b2="34.5 KV" b3="RADFRDWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="933 TWIN" b2="345 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="933 TWIN" b2="345 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="933 TWIN" b2="345 KV" b3="T3" />
      <ContingencyEquipment Action="L" Type="LN" b1="933 TWIN" b2="345 KV" b3="93301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="95 CHEST" b2="345 KV" b3="BT1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="95 CHEST" b2="345 KV" b3="BT2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96680</SeqNum>
    <Name>L138.Leesville-Yager</Name>
    <LastEdit Timestamp="2024-09-13T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESVIL2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEESVIL2" b2="138 KV" b3="LEE-YAG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YAGER" b2="138 KV" b3="D1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96700</SeqNum>
    <Name>OakHall.SP</Name>
    <LastEdit Timestamp="2026-01-09T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="180" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="188" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OAKHALL" b2="34.5 KV" b3="ES01ARSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96710</SeqNum>
    <Name>230/115.ReevesAve.TX4</Name>
    <LastEdit Timestamp="2024-09-13T09:43:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="230 KV" b3="H4T2038" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="230 KV" b3="H4T279" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="115 KV" b3="L412" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="REEVESAV" b2="230 KV" b3="SC4" />
      <ContingencyEquipment Action="X" Type="XF" b1="REEVESAV" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96720</SeqNum>
    <Name>L138.EastMonument-EastDanville</Name>
    <LastEdit Timestamp="2025-12-12T16:54:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EDANVILL" b2="138 KV" b3="EDA-EMO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDANVILL" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EMONUMEN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EMONUMEN" b2="138 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EMONUMEN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="EMONUMEN" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96730</SeqNum>
    <Name>L138.IUPurdue-RobisonPark</Name>
    <LastEdit Timestamp="2024-10-01T16:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IUPURDUE" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IUPURDUE" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IUPURDUE" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="IUPURDUE" b2="138 KV" b3="IUP-ROB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96740</SeqNum>
    <Name>L138.IUPurdue-Spyrun</Name>
    <LastEdit Timestamp="2024-10-01T16:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IUPURDUE" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IUPURDUE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IUPURDUE" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPYRUN" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="IUPURDUE" b2="138 KV" b3="IUP-SPY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96750</SeqNum>
    <Name>Wildcat.CC</Name>
    <LastEdit Timestamp="2025-04-02T15:13:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKSPRI" b2="500 KV" b3="52-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKSPRI" b2="500 KV" b3="52-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKSPRI" b2="500 KV" b3="52-CT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKSPRI" b2="500 KV" b3="52-CT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKSPRI" b2="500 KV" b3="52-ST3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKSPRI" b2="21 KV" b3="AUXLD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKSPRI" b2="21 KV" b3="AUXLD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKSPRI" b2="500 KV" b3="CTG1GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKSPRI" b2="500 KV" b3="CTG2GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKSPRI" b2="500 KV" b3="STG3GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROCKSPRI" b2="21 KV" b3="WCATCTG1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROCKSPRI" b2="21 KV" b3="WCATCTG2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROCKSPRI" b2="24 KV" b3="WCATSTG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96760</SeqNum>
    <Name>Belmont.Stonewall.CC</Name>
    <LastEdit Timestamp="2024-08-30T10:00:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLMNTDOM" b2="230 KV" b3="217812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLMNTDOM" b2="230 KV" b3="231112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLMNTDOM" b2="230 KV" b3="520" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLMNTDOM" b2="230 KV" b3="620" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLMNTDOM" b2="230 KV" b3="C1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLMNTDOM" b2="230 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLMNTDOM" b2="230 KV" b3="GSU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLMNTDOM" b2="18 KV" b3="LOAD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLMNTDOM" b2="18 KV" b3="LOAD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLMNTDOM" b2="230 KV" b3="S2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BLMNTDOM" b2="18 KV" b3="STONECT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BLMNTDOM" b2="18 KV" b3="STONECT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BLMNTDOM" b2="19 KV" b3="STONEST" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96770</SeqNum>
    <Name>L161.Barkley-PrincetonTap(TVA)</Name>
    <LastEdit Timestamp="2025-06-16T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="5PRINC_T" b2="161 KV" b3="912" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARKLEY4" b2="161 KV" b3="924" />
      <ContingencyEquipment Action="L" Type="LN" b1="BARKLEY4" b2="161 KV" b3="BAR-PRI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96790</SeqNum>
    <Name>L138.Clouse-Zanesville</Name>
    <LastEdit Timestamp="2024-09-13T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUSE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUSE" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZANESVIL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOUSE" b2="138 KV" b3="CLO-ZAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96800</SeqNum>
    <Name>L138.Tidd-GableSW</Name>
    <LastEdit Timestamp="2024-09-13T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GABLESW" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="GABLESW" b2="138 KV" b3="GAB-TID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="M2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96810</SeqNum>
    <Name>L138.Elk-Bolins-Mineral-Lemaster</Name>
    <LastEdit Timestamp="2024-11-05T14:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOLINS" b2="138 KV" b3="BOL-MIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOLINS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELK" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOLINS" b2="138 KV" b3="BOL-ELK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMASTER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEMASTER" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEMASTER" b2="138 KV" b3="LEM-MIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MINERAL" b2="138 KV" b3="BUCKEYE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96820</SeqNum>
    <Name>L138.SmithMountain-Penhook-Redwood-WestLake</Name>
    <LastEdit Timestamp="2025-09-04T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PENHOOK" b2="138 KV" b3="PEN-RED" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENHOOK" b2="138 KV" b3="PEN-SMI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENHOOK" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDWOOD" b2="138 KV" b3="RED-WES" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REDWOOD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTLAKE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTLAKE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96830</SeqNum>
    <Name>L230.CabinRun-YardleyRidge.2213</Name>
    <LastEdit Timestamp="2026-03-31T10:22:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINRUN" b2="230 KV" b3="221312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINRUN" b2="230 KV" b3="22132287" />
      <ContingencyEquipment Action="L" Type="LN" b1="CABINRUN" b2="230 KV" b3="CAB-YARR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YARDRIDG" b2="230 KV" b3="WT2213" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YARDRIDG" b2="230 KV" b3="XT2213" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96840</SeqNum>
    <Name>L230.Shellhorn-Enterprise.2186</Name>
    <LastEdit Timestamp="2025-01-24T09:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENTRPRIS" b2="230 KV" b3="H3T2186" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENTRPRIS" b2="230 KV" b3="H5T2186" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELHORN" b2="230 KV" b3="20952186" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELHORN" b2="230 KV" b3="218642" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENTRPRIS" b2="230 KV" b3="2186A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96850</SeqNum>
    <Name>L230.Lackawanna-Summit.2</Name>
    <LastEdit Timestamp="2024-09-26T16:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LACKAWAN" b2="230 KV" b3="LAC-SUM2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="SMT2LAEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="SUMIT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMITPL" b2="230 KV" b3="LACK2_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMITPL" b2="230 KV" b3="LACK2_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96860</SeqNum>
    <Name>L230.Stanton-Summit.4 + 230/69.Stanton.T4</Name>
    <LastEdit Timestamp="2024-10-23T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="STANTON" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANTON" b2="230 KV" b3="LACKAWN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STANTON" b2="230 KV" b3="STA-SUM4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANTON" b2="69 KV" b3="TRAN_4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMITPL" b2="230 KV" b3="LAC1-ST4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMITPL" b2="230 KV" b3="STAN4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96880</SeqNum>
    <Name>L138.Aetna-Babb</Name>
    <LastEdit Timestamp="2025-08-19T16:05:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AETNA" b2="138 KV" b3="B168" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AETNA" b2="138 KV" b3="B169" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABB" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BABB" b2="138 KV" b3="A4" />
      <ContingencyEquipment Action="L" Type="LN" b1="AETNA" b2="138 KV" b3="AET-BABB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96910</SeqNum>
    <Name>138/69.WestEndFostoria.T5</Name>
    <LastEdit Timestamp="2024-09-13T09:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WEFOSTOR" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEFOSTOR" b2="69 KV" b3="S" />
      <ContingencyEquipment Action="X" Type="XF" b1="WEFOSTOR" b2="138 KV" b3="T5 XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96920</SeqNum>
    <Name>138/69.WestEndFostoria.T6</Name>
    <LastEdit Timestamp="2024-09-13T09:42:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WEFOSTOR" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEFOSTOR" b2="69 KV" b3="R" />
      <ContingencyEquipment Action="X" Type="XF" b1="WEFOSTOR" b2="138 KV" b3="T6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96930</SeqNum>
    <Name>L230.PrenticeDrive-Greenway-Shellhorn.2188</Name>
    <LastEdit Timestamp="2026-03-06T10:31:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GREENWAY" b2="230 KV" b3="2188B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENWAY" b2="230 KV" b3="GRE-PREN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWAY" b2="230 KV" b3="H262 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWAY" b2="230 KV" b3="H362 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENWAY" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENWAY" b2="34.5 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENWAY" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENWAY" b2="34.5 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRENTICE" b2="230 KV" b3="218832" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRENTICE" b2="230 KV" b3="ZT2188" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELHORN" b2="230 KV" b3="218842" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELHORN" b2="230 KV" b3="WT2188" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96940</SeqNum>
    <Name>L138.SouthBluefield-TownCreek-Progress</Name>
    <LastEdit Timestamp="2025-06-23T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PROGRESS" b2="138 KV" b3="E CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="PROGRESS" b2="138 KV" b3="PRO-TOW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBLUEFIE" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="L" Type="LN" b1="SBLUEFIE" b2="138 KV" b3="SBL-TOW" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TOWNCRK" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWNCRK" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96950</SeqNum>
    <Name>138/69.BluffPoint.T1</Name>
    <LastEdit Timestamp="2024-09-13T09:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUFFPOI" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUFFPOI" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUFFPOI" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUFFPOI" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96960</SeqNum>
    <Name>Lyons.BluffPointWF</Name>
    <LastEdit Timestamp="2024-09-13T09:49:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUFFPOI" b2="138 KV" b3="52-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BLUFFPOI" b2="34.5 KV" b3="BLFFPTWF" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BLUFFPOI" b2="34.5 KV" b3="C1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUFFPOI" b2="138 KV" b3="GSU1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96970</SeqNum>
    <Name>Buckingham.230.Reactor2-1</Name>
    <LastEdit Timestamp="2024-09-13T09:54:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKINGH" b2="230 KV" b3="265 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BUCKINGH" b2="230 KV" b3="BUCK2-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>96980</SeqNum>
    <Name>L138.Circleville-Harrison.2</Name>
    <LastEdit Timestamp="2024-12-24T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CIRCLEVI" b2="138 KV" b3="AC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CIRCLEVI" b2="138 KV" b3="AD" />
      <ContingencyEquipment Action="L" Type="LN" b1="CIRCLEVI" b2="138 KV" b3="CIR-HAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISCS" b2="138 KV" b3="3C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISCS" b2="138 KV" b3="3W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97000</SeqNum>
    <Name>L138.BeaverCreek-Topmost-Beckham</Name>
    <LastEdit Timestamp="2024-09-16T10:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVERCR" b2="138 KV" b3="BEA-TOP1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BEAVERCR" b2="138 KV" b3="HASP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERCR" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="BECKHAM" b2="138 KV" b3="BEC-TOP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKHAM" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TOPMOST" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97010</SeqNum>
    <Name>L138.Amos-CrookedCreek-PoplarFork-BallsGap</Name>
    <LastEdit Timestamp="2024-09-16T10:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMOS" b2="138 KV" b3="AMO-CRO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALLSGAP" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CROOKEDC" b2="138 KV" b3="LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BALLSGAP" b2="138 KV" b3="BAL-POP" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROOKEDC" b2="138 KV" b3="CRO-POP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POPLARFO" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97020</SeqNum>
    <Name>L230.Crest-Colora.22704</Name>
    <LastEdit Timestamp="2025-04-02T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLORA" b2="230 KV" b3="233" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLORA" b2="230 KV" b3="745 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CREST" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CREST" b2="230 KV" b3="234" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLORA" b2="230 KV" b3="COL-CRE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97030</SeqNum>
    <Name>L230.FourRiver-Doswell.2125 + Doswell.CT2&amp;CT3</Name>
    <LastEdit Timestamp="2024-12-24T13:48:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="DOSWELL" b2="18 KV" b3="DOSWLCT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DOSWELL" b2="18 KV" b3="DOSWLCT3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOSWELL" b2="230 KV" b3="GSU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOSWELL" b2="230 KV" b3="GSU3" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOSWELL" b2="230 KV" b3="GSU_2" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOSWELL" b2="230 KV" b3="GSU_3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOSWELL" b2="230 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="230 KV" b3="20442125" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOSWELL" b2="230 KV" b3="2125" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="230 KV" b3="256T2125" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97040</SeqNum>
    <Name>L230.Stanton-Summit.3 + 230/69.Stanton.T2</Name>
    <LastEdit Timestamp="2024-09-16T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="STANTON" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANTON" b2="230 KV" b3="LACKAWN2" />
      <ContingencyEquipment Action="L" Type="LN" b1="STANTON" b2="230 KV" b3="STA-SUM3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANTON" b2="69 KV" b3="TRAN_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMITPL" b2="230 KV" b3="STAN3_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMITPL" b2="230 KV" b3="STAN3_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97140</SeqNum>
    <Name>940 Cordova.CC</Name>
    <LastEdit Timestamp="2024-09-16T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="21QC906C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="22QC907C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="940 CORD" b2="345 KV" b3="23QC908C" />
      <ContingencyEquipment Action="U" Type="GEN" b1="940 CORD" b2="18 KV" b3="CD-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="940 CORD" b2="18 KV" b3="CD-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="940 CORD" b2="18 KV" b3="CD-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97170</SeqNum>
    <Name>L230.Richmon-Hamlet(CPL) + Hamlet.Units</Name>
    <LastEdit Timestamp="2024-09-16T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMLET" b2="230 KV" b3="CB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAMLET" b2="230 KV" b3="CB3" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAMLET" b2="230 KV" b3="HAM-RIC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HAMLTDOM" b2="13.8 KV" b3="G2_INT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HAMLTDOM" b2="13.8 KV" b3="G3_INT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HAMLTDOM" b2="13.8 KV" b3="G6_INT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHMON" b2="230 KV" b3="NCHP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHMON" b2="230 KV" b3="NCHPRA2S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97180</SeqNum>
    <Name>L230.Crest-Cecil.23005</Name>
    <LastEdit Timestamp="2024-09-16T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CECIL" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CECIL" b2="230 KV" b3="233" />
      <ContingencyEquipment Action="L" Type="LN" b1="CECIL" b2="230 KV" b3="CEC-CRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CREST" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CREST" b2="230 KV" b3="233" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97190</SeqNum>
    <Name>L115.Altavista-OtterRiver-Grit-Perth.31</Name>
    <LastEdit Timestamp="2025-05-22T13:32:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAVSTA" b2="115 KV" b3="3132" />
      <ContingencyEquipment Action="L" Type="LN" b1="OTTERRIV" b2="115 KV" b3="31A" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRITDP" b2="115 KV" b3="GRI-PERT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRITDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="OTTERRIV" b2="115 KV" b3="31B" />
      <ContingencyEquipment Action="X" Type="XF" b1="OTTERRIV" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OTTERRIV" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="OTTERRIV" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OTTERRIV" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERTH" b2="115 KV" b3="3142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERTH" b2="115 KV" b3="31T1022" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97200</SeqNum>
    <Name>L115.WoodchuckTrail-CrystalHill-Perth.1016</Name>
    <LastEdit Timestamp="2025-10-16T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRSTLHDP" b2="115 KV" b3="1016" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRSTLHDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERTH" b2="115 KV" b3="10161022" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERTH" b2="115 KV" b3="101642" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WDCHKTRL" b2="115 KV" b3="10161047" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WDCHKTRL" b2="115 KV" b3="101672" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRSTLHDP" b2="115 KV" b3="CRS-WDCH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97210</SeqNum>
    <Name>230/26.Brunswick.220-3</Name>
    <LastEdit Timestamp="2024-12-17T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SECT 2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SECT 7-8" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNSWIC" b2="230 KV" b3="TRAN 3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRUNSWIC" b2="26 KV" b3="TRANDIS3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97230</SeqNum>
    <Name>L69.Beckett-Paulsboro.0614</Name>
    <LastEdit Timestamp="2025-11-21T15:07:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BECKETT" b2="69 KV" b3="BEC-PAU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKETT" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAULSBRO" b2="69 KV" b3="OCB P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97240</SeqNum>
    <Name>L138.Cloverdale-Catawba</Name>
    <LastEdit Timestamp="2024-09-16T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CATAWBA" b2="138 KV" b3="CAT-CLO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CATAWBA" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97250</SeqNum>
    <Name>L138.Wagenhal-JuneRoad</Name>
    <LastEdit Timestamp="2024-12-18T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNEROAD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNEROAD" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUNEROAD" b2="138 KV" b3="JUN-WAG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97320</SeqNum>
    <Name>138/69.BearWallow.T1</Name>
    <LastEdit Timestamp="2024-12-02T12:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARWALO" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEARWALO" b2="138 KV" b3="BEA-FAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEARWALO" b2="69 KV" b3="BEA-JEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARWALO" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEARWALO" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97360</SeqNum>
    <Name>L138.Bayway-DoremusPl.Q1369 + 345/138.Bayway.T5</Name>
    <LastEdit Timestamp="2024-09-19T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="15-16" />
      <ContingencyEquipment Action="X" Type="XF" b1="BAYWAY" b2="345 KV" b3="345-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="4-16" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYWAY" b2="138 KV" b3="BAY-DOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOREMUSP" b2="138 KV" b3="SECT 2-3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOREMUSP" b2="138 KV" b3="T-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOREMUSP" b2="138 KV" b3="T-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97370</SeqNum>
    <Name>230/26.Brunswick.T2</Name>
    <LastEdit Timestamp="2024-09-19T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SECT 1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SECT 5-6" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNSWIC" b2="230 KV" b3="TRAN 2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRUNSWIC" b2="26 KV" b3="TRANDIS2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97410</SeqNum>
    <Name>138/69.Catawba.T1</Name>
    <LastEdit Timestamp="2024-09-16T10:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CATAWBA" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="CATAWBA" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="CATAWBA" b2="34 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CATAWBA" b2="34 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CATAWBA" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CATAWBA" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97420</SeqNum>
    <Name>230/115.ReevesAve.TX5</Name>
    <LastEdit Timestamp="2024-09-16T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="230 KV" b3="H5T2038" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="230 KV" b3="H5T279" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="115 KV" b3="L512" />
      <ContingencyEquipment Action="X" Type="XF" b1="REEVESAV" b2="230 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97450</SeqNum>
    <Name>L138.HillCres-Waynedal</Name>
    <LastEdit Timestamp="2024-09-16T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HILLCRES" b2="138 KV" b3="HIL-WAY2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLCRES" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNEDAL" b2="138 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97460</SeqNum>
    <Name>L345.Whitestown-Guion (CIN)</Name>
    <LastEdit Timestamp="2024-09-17T12:57:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GUION" b2="345 KV" b3="22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUION" b2="345 KV" b3="24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITESTO" b2="345 KV" b3="03-24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITESTO" b2="345 KV" b3="B1-03" />
      <ContingencyEquipment Action="L" Type="LN" b1="WHITESTO" b2="345 KV" b3="WHI-GUI1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97610</SeqNum>
    <Name>L138.CapitolHill-BullittStreet</Name>
    <LastEdit Timestamp="2024-11-21T14:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLITST" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BULLITST" b2="138 KV" b3="BUL-CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPITOLH" b2="138 KV" b3="P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97620</SeqNum>
    <Name>L138.Aviation-Waynedale</Name>
    <LastEdit Timestamp="2024-09-16T10:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AVIATION" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVIATION" b2="138 KV" b3="AVI-WAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNEDAL" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97640</SeqNum>
    <Name>L138.BerryWood-Berkshire</Name>
    <LastEdit Timestamp="2024-09-16T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKSHI2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERRYWOD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERKSHI2" b2="138 KV" b3="BER-BER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERRYWOD" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97660</SeqNum>
    <Name>L138.Lakemore-Clayben-SouthAkron</Name>
    <LastEdit Timestamp="2024-09-17T12:53:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYOE" b2="138 KV" b3="CS3" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKEMORE" b2="138 KV" b3="LAK-CLA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAKRONFE" b2="138 KV" b3="SAK-CLA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLAYOE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEMORE" b2="138 KV" b3="B51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEMORE" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SAKRONFE" b2="138 KV" b3="A364" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRONFE" b2="138 KV" b3="B30" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97680</SeqNum>
    <Name>L138.7StateLine-55Hegewisch.0703</Name>
    <LastEdit Timestamp="2025-10-28T11:39:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="7 STATE" b2="138 KV" b3="0703 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="55 HEGEW" b2="138 KV" b3="0703 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="0703" b2="138 KV" b3="0703 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="0703" b2="138 KV" b3="0703 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="955 RIVE" b2="138 KV" b3="0703 5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="55 HEGEW" b2="138 KV" b3="BT3-6CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="55 HEGEW" b2="138 KV" b3="BT5-6CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="7 STATE" b2="138 KV" b3="L0703 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="955 RIVE" b2="138 KV" b3="L0703 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="Z715" b2="138 KV" b3="BT1-2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="Z715" b2="138 KV" b3="L0703 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="Z715" b2="138 KV" b3="TR73_12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97700</SeqNum>
    <Name>L69.BearWallow-JewellRidge</Name>
    <LastEdit Timestamp="2024-09-16T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEARWALO" b2="69 KV" b3="BEA-JEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARWALO" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="JEWELRDG" b2="69 KV" b3="JEW-RIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLAND" b2="69 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97720</SeqNum>
    <Name>L138.77Mazon-433ChannahonWest.7719</Name>
    <LastEdit Timestamp="2026-03-31T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="433 CHAN" b2="138 KV" b3="7719 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="433 CHAN" b2="138 KV" b3="7719 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="77 MAZON" b2="138 KV" b3="77197713" />
      <ContingencyEquipment Action="OP" Type="CB" b1="77 MAZON" b2="34.5 KV" b3="TR76 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRBN" b2="138 KV" b3="CRB-MAZO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97740</SeqNum>
    <Name>230/34.NorthAlexandria.T3</Name>
    <LastEdit Timestamp="2024-09-16T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHALEX" b2="230 KV" b3="202362-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHALEX" b2="230 KV" b3="211262-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHALEX" b2="230 KV" b3="H362" />
      <ContingencyEquipment Action="X" Type="XF" b1="NRTHALEX" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97750</SeqNum>
    <Name>L115.Carolina-LkGaston-FiveForks-PalmerSpring.90</Name>
    <LastEdit Timestamp="2024-11-13T14:48:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAROLINA" b2="115 KV" b3="9002" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CAROLINA" b2="115 KV" b3="9008" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIVEFRKS" b2="115 KV" b3="90C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIVEFRKS" b2="115 KV" b3="90E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FIVEFRKS" b2="115 KV" b3="HEC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LITTLEDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LKGASTON" b2="115 KV" b3="90A" />
      <ContingencyEquipment Action="L" Type="LN" b1="LKGASTON" b2="115 KV" b3="90B" />
      <ContingencyEquipment Action="X" Type="XF" b1="LKGASTON" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LKGASTON" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERSP" b2="115 KV" b3="90T1004" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERSP" b2="115 KV" b3="90T1019" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97760</SeqNum>
    <Name>L115.PalmerSpring-KerrDam.1019A</Name>
    <LastEdit Timestamp="2024-09-16T10:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KERRDAM" b2="115 KV" b3="1019A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="85" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERSP" b2="115 KV" b3="10041019" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALMERSP" b2="115 KV" b3="90T1019" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97770</SeqNum>
    <Name>L138.Jenning-Clark.Q13</Name>
    <LastEdit Timestamp="2025-10-07T10:32:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARK_C" b2="138 KV" b3="Q1_T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLARK_C" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="JENNING" b2="138 KV" b3="JEN-CLA2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97780</SeqNum>
    <Name>345/138.Cole.T2</Name>
    <LastEdit Timestamp="2024-09-17T12:46:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="345 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLE" b2="345 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97800</SeqNum>
    <Name>L138.177Burnham-17714-55Hegewisch.17714</Name>
    <LastEdit Timestamp="2024-12-12T14:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="177 BURN" b2="138 KV" b3="L17714CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="177 BURN" b2="138 KV" b3="17714 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="55 HEGEW" b2="138 KV" b3="17714 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="17714" b2="138 KV" b3="17714 3" />
      <ContingencyEquipment Action="S" Type="SD" b1="17714" b2="138 KV" b3="17714 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="43 WILDW" b2="138 KV" b3="17714 6" />
      <ContingencyEquipment Action="L" Type="LN" b1="17714" b2="138 KV" b3="17714 8" />
      <ContingencyEquipment Action="L" Type="LN" b1="17714" b2="138 KV" b3="17714 9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="43 WILDW" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="55 HEGEW" b2="138 KV" b3="BT1-11CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="55 HEGEW" b2="138 KV" b3="BT11-12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="G385-1" b2="138 KV" b3="1412 M" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="G385-1" b2="138 KV" b3="BT1120D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="Z524" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="Z524" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97810</SeqNum>
    <Name>138/12.Hegewisch.TR71</Name>
    <LastEdit Timestamp="2025-06-18T12:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="55 HEGEW" b2="138 KV" b3="BT1-5CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="55 HEGEW" b2="138 KV" b3="BT5-6CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="55 HEGEW" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97820</SeqNum>
    <Name>138/12.Hegewisch.TR72</Name>
    <LastEdit Timestamp="2025-06-18T12:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="55 HEGEW" b2="138 KV" b3="BT1-14CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="55 HEGEW" b2="138 KV" b3="BT13-14" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="55 HEGEW" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97830</SeqNum>
    <Name>138/12.Hegewisch.TR75</Name>
    <LastEdit Timestamp="2025-06-18T12:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="55 HEGEW" b2="138 KV" b3="BT13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="55 HEGEW" b2="138 KV" b3="BT3-13CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="55 HEGEW" b2="138 KV" b3="TR75 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97840</SeqNum>
    <Name>DTX138.Hegewisch.TR76</Name>
    <LastEdit Timestamp="2025-04-07T15:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="55 HEGEW" b2="138 KV" b3="BT11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="55 HEGEW" b2="138 KV" b3="BT3-12CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="55 HEGEW" b2="138 KV" b3="TR76 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97870</SeqNum>
    <Name>L138.Farmville-Moran-FlatCreek-Lonepine.158</Name>
    <LastEdit Timestamp="2025-08-11T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="115 KV" b3="15832" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLATCREE" b2="115 KV" b3="FLA-LONE" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLATCREE" b2="115 KV" b3="FLA-MORA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLATCREE" b2="13 KV" b3="LD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLATCREE" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONEPINE" b2="115 KV" b3="158T1007" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONEPINE" b2="115 KV" b3="1T158" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORANDP" b2="115 KV" b3="158A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MORANDP" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97880</SeqNum>
    <Name>L138.Lonepine-Hooper-Jetersville-Ponton</Name>
    <LastEdit Timestamp="2024-09-17T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HOOPERDP" b2="115 KV" b3="HOO-JET" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOOPERDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JETERSVL" b2="35 KV" b3="AMELIA" />
      <ContingencyEquipment Action="L" Type="LN" b1="JETERSVL" b2="115 KV" b3="JET-PONT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JETERSVL" b2="35 KV" b3="POINTON" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JETERSVL" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONEPINE" b2="115 KV" b3="10071034" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOOPERDP" b2="115 KV" b3="1007A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONEPINE" b2="115 KV" b3="158T1007" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PONTON" b2="115 KV" b3="DP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97910</SeqNum>
    <Name>L345.LakeRedMonRoad-MillCreek</Name>
    <LastEdit Timestamp="2025-11-06T14:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LKREDMNR" b2="345 KV" b3="904" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LKREDMNR" b2="345 KV" b3="914" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="4504_60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL_CRE" b2="345 KV" b3="CB4560" />
      <ContingencyEquipment Action="L" Type="LN" b1="LKREDMNR" b2="345 KV" b3="LKR-MILL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>97920</SeqNum>
    <Name>L138.LonePine-FtPicket.1</Name>
    <LastEdit Timestamp="2024-09-17T12:56:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FTPICKET" b2="115 KV" b3="DP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FTPICKET" b2="115 KV" b3="DP1LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FTPICKET" b2="115 KV" b3="H122" />
      <ContingencyEquipment Action="X" Type="XF" b1="FTPICKET" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FTPICKET" b2="115 KV" b3="1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONEPINE" b2="115 KV" b3="1T1034" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONEPINE" b2="115 KV" b3="1T158" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONEPINE" b2="115 KV" b3="SC102" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98000</SeqNum>
    <Name>138/23.Wilson.T1</Name>
    <LastEdit Timestamp="2024-09-19T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="23 KV" b3="T1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE5-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WILSON" b2="138 KV" b3="T_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98001</SeqNum>
    <Name>138/23.Wilson.T2</Name>
    <LastEdit Timestamp="2024-09-17T12:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="23 KV" b3="T2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE3-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE3-8" />
      <ContingencyEquipment Action="X" Type="XF" b1="WILSON" b2="138 KV" b3="T_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98002</SeqNum>
    <Name>138/23.Wilson.T3</Name>
    <LastEdit Timestamp="2024-09-17T12:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="23 KV" b3="T3CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE4-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE6-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="WILSON" b2="138 KV" b3="T_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98007</SeqNum>
    <Name>DTX230.LewisRun.TR6</Name>
    <LastEdit Timestamp="2024-09-26T16:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISRN" b2="230 KV" b3="B63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISRN" b2="230 KV" b3="B64" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEWISRN" b2="230 KV" b3="TR6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98009</SeqNum>
    <Name>L138.Bosserman-Marquette</Name>
    <LastEdit Timestamp="2024-12-12T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOSSERMN" b2="138 KV" b3="BOS-MAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUETT" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARQUETT" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98010</SeqNum>
    <Name>L138.Marquette-Kuchar-SilverLake</Name>
    <LastEdit Timestamp="2025-04-07T15:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KUCHAR" b2="138 KV" b3="KUC-SIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KUCHAR" b2="138 KV" b3="LIQUID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUETT" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="KUCHAR" b2="138 KV" b3="KUC-MAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARQUETT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUETT" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERLK" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SILVERLK" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERLK" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98011</SeqNum>
    <Name>L138.SilverLake-BattSkid-Olive</Name>
    <LastEdit Timestamp="2026-05-08T15:18:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BATTSKID" b2="138 KV" b3="BAT-OLIV" />
      <ContingencyEquipment Action="L" Type="LN" b1="BATTSKID" b2="138 KV" b3="BAT-SILV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BATTSKID" b2="138 KV" b3="GMLOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="138 KV" b3="N1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERLK" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SILVERLK" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERLK" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98012</SeqNum>
    <Name>L138.NewCarlisle-Bosserni-Bosserman.Line2</Name>
    <LastEdit Timestamp="2025-02-20T13:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOSSERMN" b2="138 KV" b3="BOS-BNI2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOSSERNI" b2="138 KV" b3="BOS-NNI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCARLI" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWCARLI" b2="138 KV" b3="NEW-NWN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98013</SeqNum>
    <Name>765/345.Dumont.T3</Name>
    <LastEdit Timestamp="2024-10-02T14:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="765 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="765 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="345 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="345 KV" b3="E1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DUMONT2" b2="765 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98016</SeqNum>
    <Name>L138.IndustrialPark-Beckwith</Name>
    <LastEdit Timestamp="2026-01-12T11:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKWITH" b2="138 KV" b3="M00061" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKWITH" b2="138 KV" b3="M001D2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BECKWITH" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BECKWITH" b2="138 KV" b3="BEC-INDU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDUSTRI" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98018</SeqNum>
    <Name>L230.Boonetown-SouthReading</Name>
    <LastEdit Timestamp="2024-12-09T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONETWN" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONETWN" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOONETWN" b2="230 KV" b3="BOO-SRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SREADING" b2="230 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98019</SeqNum>
    <Name>L230.Boonetown-Birdsboro + Birdsboro.CT1</Name>
    <LastEdit Timestamp="2026-01-23T09:28:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIRDBORO" b2="230 KV" b3="01" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BIRDBORO" b2="23 KV" b3="AUX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BIRDBORO" b2="23 KV" b3="AUX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIRDBORO" b2="230 KV" b3="BIR-BOO" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BIRDBORO" b2="23 KV" b3="CT1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BIRDBORO" b2="230 KV" b3="GSU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONETWN" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONETWN" b2="230 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98020</SeqNum>
    <Name>345/138.Bayonne.TX4</Name>
    <LastEdit Timestamp="2024-11-13T12:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="345 KV" b3="2-10" />
      <ContingencyEquipment Action="X" Type="XF" b1="BAYONNE" b2="345 KV" b3="345-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="345 KV" b3="9-10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BAYONNE" b2="138 KV" b3="BAYON2SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BAYONNE" b2="138 KV" b3="BAYONNSP" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BAYONNE" b2="345 KV" b3="RC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="138 KV" b3="SECT 2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="138 KV" b3="T-10CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="138 KV" b3="T-40CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BAYONNE" b2="138 KV" b3="T10-LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BAYONNE" b2="138 KV" b3="T40-LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98021</SeqNum>
    <Name>L345.Bayonne-Bayway.F-3432</Name>
    <LastEdit Timestamp="2024-10-25T13:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="345 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="3-13" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYONNE" b2="345 KV" b3="BYO-BAY" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BAYWAY" b2="345 KV" b3="RC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="RC2_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98022</SeqNum>
    <Name>L230.WestOrange-OrangeHeights.V-2327</Name>
    <LastEdit Timestamp="2026-01-23T09:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ORANGEHT" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORANGEHT" b2="230 KV" b3="1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORANGE" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORANGE" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="ORANGEHT" b2="230 KV" b3="ORA-WORA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98023</SeqNum>
    <Name>230/69.Brunswick.TX4</Name>
    <LastEdit Timestamp="2024-10-22T16:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="69 KV" b3="2-10" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNSWIC" b2="230 KV" b3="220-4 XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="69 KV" b3="9-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SEC13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SECT4-14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98024</SeqNum>
    <Name>L345.Bayway-NorthAve.U-3473</Name>
    <LastEdit Timestamp="2025-10-30T16:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="15-16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="3-15" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYWAY" b2="345 KV" b3="BAY-NOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHAV" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHAV" b2="345 KV" b3="1-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98027</SeqNum>
    <Name>L138.Sorenson-Huntington (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-17T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTINGT" b2="138 KV" b3="HUN-SOR1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HUNTINGT" b2="138 KV" b3="Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="L2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98038</SeqNum>
    <Name>L138.PineyGrove-Wattsville.13751</Name>
    <LastEdit Timestamp="2024-09-26T16:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEYGRO" b2="138 KV" b3="8870" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINEYGRO" b2="138 KV" b3="PIN-WAT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98040</SeqNum>
    <Name>L230.Dawkins-VintHill.2163</Name>
    <LastEdit Timestamp="2025-12-10T16:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAWKINSB" b2="230 KV" b3="216342" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAWKINSB" b2="230 KV" b3="DAW-VINT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAWKINSB" b2="230 KV" b3="ZT2163" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINTHILL" b2="230 KV" b3="21012163" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINTHILL" b2="230 KV" b3="21632174" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98041</SeqNum>
    <Name>L230.Milton-Sunbury.1</Name>
    <LastEdit Timestamp="2024-05-21T15:04:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MILTON" b2="230 KV" b3="MIL-SUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON" b2="230 KV" b3="MON2SUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON" b2="230 KV" b3="SUNB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="MIL1SUS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="MILT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98042</SeqNum>
    <Name>L230.Milton-Montour.1</Name>
    <LastEdit Timestamp="2024-07-07T08:33:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MILTON" b2="230 KV" b3="MIL-MON1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON" b2="230 KV" b3="MON1SUN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON" b2="230 KV" b3="MONT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="MILT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="MILTSAE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98043</SeqNum>
    <Name>230/69.Milton.T1</Name>
    <LastEdit Timestamp="2024-10-24T14:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MILTON" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON" b2="230 KV" b3="T1_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98044</SeqNum>
    <Name>230/69.Milton.T2</Name>
    <LastEdit Timestamp="2024-10-18T13:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MILTON" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON" b2="230 KV" b3="T2_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON" b2="69 KV" b3="TRAN_2_" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98045</SeqNum>
    <Name>L345.Bayonne-Marion.L3438</Name>
    <LastEdit Timestamp="2024-10-03T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="345 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="345 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYONNE" b2="345 KV" b3="BYO-MAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION" b2="345 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION" b2="345 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98046</SeqNum>
    <Name>138/26.Athenia.132-1</Name>
    <LastEdit Timestamp="2024-09-17T12:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="1-9" />
      <ContingencyEquipment Action="X" Type="XF" b1="ATHENIA" b2="138 KV" b3="132-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98047</SeqNum>
    <Name>138/26.Athenia.132-2</Name>
    <LastEdit Timestamp="2024-09-17T12:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="1-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="11-12" />
      <ContingencyEquipment Action="X" Type="XF" b1="ATHENIA" b2="138 KV" b3="132-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98048</SeqNum>
    <Name>138/25.Keisters.T1</Name>
    <LastEdit Timestamp="2025-04-01T15:52:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEISTERS" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEISTERS" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEISTERS" b2="25 KV" b3="T1 LS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEISTERS" b2="138 KV" b3="T1 XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98049</SeqNum>
    <Name>L230.Cromby-Lock.220-99</Name>
    <LastEdit Timestamp="2024-09-26T16:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="230 KV" b3="615 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROMBY" b2="230 KV" b3="CRO-LOC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCK" b2="230 KV" b3="805" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCK" b2="230 KV" b3="905" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98050</SeqNum>
    <Name>345/138.Linden.345-3</Name>
    <LastEdit Timestamp="2024-12-09T15:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="138 KV" b3="11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="345 KV" b3="2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="138 KV" b3="2-12" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="345 KV" b3="345-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="345 KV" b3="9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98051</SeqNum>
    <Name>L345.Bayonne-NorthAvenue.G-3433</Name>
    <LastEdit Timestamp="2025-10-30T15:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="345 KV" b3="2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="345 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYONNE" b2="345 KV" b3="BYO-NOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHAV" b2="345 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHAV" b2="345 KV" b3="4-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98053</SeqNum>
    <Name>L345.Fargo-MapleRidge</Name>
    <LastEdit Timestamp="2024-09-17T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FARGO  3" b2="345 KV" b3="FAR-MAPL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARGO  3" b2="345 KV" b3="V25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARGO  3" b2="345 KV" b3="V33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLERID" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAPLERID" b2="345 KV" b3="V9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98054</SeqNum>
    <Name>L345.Fargo-Sandbrg</Name>
    <LastEdit Timestamp="2025-11-14T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FARGO  3" b2="345 KV" b3="FAR-SAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARGO  3" b2="345 KV" b3="V23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARGO  3" b2="345 KV" b3="V31" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SANDBRG" b2="345 KV" b3="SNBG_WF1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDBRG" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDBRG" b2="345 KV" b3="V23" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98055</SeqNum>
    <Name>L345.Oakgrove-Sandburg (MEC)</Name>
    <LastEdit Timestamp="2024-11-27T16:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGRMEC" b2="345 KV" b3="Q10903" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGRMEC" b2="345 KV" b3="Q10904" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKGRMEC" b2="345 KV" b3="OAK-SAND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDBRG" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDBRG" b2="345 KV" b3="V13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98059</SeqNum>
    <Name>L138.Carville-WyeMills.13769</Name>
    <LastEdit Timestamp="2024-10-30T15:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARVILLE" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARVILLE" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="138 KV" b3="132 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="138 KV" b3="133 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARVILLE" b2="138 KV" b3="CAR-WYE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98061</SeqNum>
    <Name>DTX138.Vulcan.TR8</Name>
    <LastEdit Timestamp="2025-05-20T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VULCAN" b2="138 KV" b3="B13393" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VULCAN" b2="138 KV" b3="B13395" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VULCAN" b2="138 KV" b3="B13396" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VULCAN" b2="138 KV" b3="B13397" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VULCAN" b2="138 KV" b3="B13398" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VULCAN" b2="69 KV" b3="B6982" />
      <ContingencyEquipment Action="X" Type="XF" b1="VULCAN" b2="138 KV" b3="TR10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98062</SeqNum>
    <Name>L138.Stanville-MorganFork</Name>
    <LastEdit Timestamp="2024-10-30T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANFK" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORGANFK" b2="138 KV" b3="MOR-STA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANVILL" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98063</SeqNum>
    <Name>L500.Alburtis-Breinigsville.5059 </Name>
    <LastEdit Timestamp="2025-04-23T12:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBURTIS" b2="500 KV" b3="ALB-BRN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTIS" b2="500 KV" b3="BREI1_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBURTIS" b2="500 KV" b3="BREI1_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRNGSVIL" b2="500 KV" b3="ALBRTS1E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRNGSVIL" b2="500 KV" b3="ALBRTS1W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98064</SeqNum>
    <Name>L500.Hunterstown-Vinco.5068</Name>
    <LastEdit Timestamp="2026-04-17T14:31:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="500 KV" b3="B153" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="500 KV" b3="B154" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTERST" b2="500 KV" b3="HUN-VIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINCO" b2="500 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINCO" b2="500 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98065</SeqNum>
    <Name>DTX230.Lewistown.T2</Name>
    <LastEdit Timestamp="2025-11-04T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B66" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISTOW" b2="230 KV" b3="B85" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEWISTOW" b2="230 KV" b3="T2_LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98069</SeqNum>
    <Name>L500.Fairview-Vinco + Fairview.CC</Name>
    <LastEdit Timestamp="2024-08-20T09:15:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRVWEC" b2="500 KV" b3="1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRVWEC" b2="500 KV" b3="1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRVWEC" b2="500 KV" b3="1S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRVWEC" b2="500 KV" b3="1Z" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FAIRVWEC" b2="25 KV" b3="CT-1A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FAIRVWEC" b2="25 KV" b3="CT-1B" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAIRVWEC" b2="500 KV" b3="FAI-VIN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FAIRVWEC" b2="23.5 KV" b3="S1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINCO" b2="500 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINCO" b2="500 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98070</SeqNum>
    <Name>L345.Bayonne-Marion.D-3404</Name>
    <LastEdit Timestamp="2024-10-16T13:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="345 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYONNE" b2="345 KV" b3="BYO-MAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION" b2="345 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION" b2="345 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98071</SeqNum>
    <Name>L345.Bayway-NewarkAirport.O-3467</Name>
    <LastEdit Timestamp="2024-09-17T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYWAY" b2="345 KV" b3="BAY-NEW" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BAYWAY" b2="345 KV" b3="RC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWRKARPT" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWRKARPT" b2="345 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98072</SeqNum>
    <Name>L138.BlueRacer-Herlan</Name>
    <LastEdit Timestamp="2024-11-05T14:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLUERACE" b2="138 KV" b3="BLUE-HER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUERACE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERLAN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERLAN" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98073</SeqNum>
    <Name>L345.Gibson-Bedford(CIN)</Name>
    <LastEdit Timestamp="2025-11-18T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD2" b2="345 KV" b3="06B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD2" b2="345 KV" b3="2106" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEDFORD2" b2="345 KV" b3="BED-GIB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON2" b2="345 KV" b3="06G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON2" b2="345 KV" b3="4506" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98075</SeqNum>
    <Name>DTX138.Hamilton.TR1&amp;TR3</Name>
    <LastEdit Timestamp="2025-05-12T14:25:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02HAMLTN" b2="138 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02HAMLTN" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02HAMLTN" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02HAMLTN" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98076</SeqNum>
    <Name>DTX138.Hamilton.TR2&amp;TR4</Name>
    <LastEdit Timestamp="2025-05-12T14:25:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02HAMLTN" b2="138 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02HAMLTN" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02HAMLTN" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02HAMLTN" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98080</SeqNum>
    <Name>DTX138.Westgate.TR1</Name>
    <LastEdit Timestamp="2025-04-07T11:44:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02WESTGT" b2="138 KV" b3="3316" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02WESTGT" b2="138 KV" b3="B13315" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02WESTGT" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98082</SeqNum>
    <Name>DTX138.Itasca.TR71</Name>
    <LastEdit Timestamp="2026-03-06T12:01:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="101 ITAS" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="101 ITAS" b2="138 KV" b3="TR71 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98083</SeqNum>
    <Name>DTX138.Allentown.T2</Name>
    <LastEdit Timestamp="2024-05-15T08:09:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="ALLENTOW" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="BUSSEC13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="BUSTIECB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="CAP_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="CEAL_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="SIEG_1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLENTOW" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98084</SeqNum>
    <Name>DTX138.Itasca.TR73</Name>
    <LastEdit Timestamp="2026-05-05T14:13:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="101 ITAS" b2="138 KV" b3="11-17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="BT3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="L10117CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="101 ITAS" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="TR82 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98085</SeqNum>
    <Name>DTX138.Allentown.T3</Name>
    <LastEdit Timestamp="2024-05-15T08:10:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="BUSSEC13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="CEAL_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="SIEG_2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLENTOW" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98086</SeqNum>
    <Name>DTX138.AvonLake.T800B</Name>
    <LastEdit Timestamp="2025-09-29T14:25:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AVONLAK2" b2="138 KV" b3="800_B" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVONLAK2" b2="138 KV" b3="AVO-02A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVONLAK2" b2="138 KV" b3="AVO-AVO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="138 KV" b3="B102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVONLAK2" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="AVONLAK2" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98092</SeqNum>
    <Name>DTX138.ProspectHeights.TR73</Name>
    <LastEdit Timestamp="2024-09-17T12:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="117 PROS" b2="138 KV" b3="11701 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="L11701CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="117 PROS" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98093</SeqNum>
    <Name>DTX138.Berkshire.T1</Name>
    <LastEdit Timestamp="2024-09-17T12:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BERKSHI2" b2="138 KV" b3="BER-BER" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERKSHI2" b2="138 KV" b3="BER-SUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKSHI2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKSHI2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERKSHI2" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98097</SeqNum>
    <Name>DTX138.MCCook.TR76</Name>
    <LastEdit Timestamp="2024-10-03T15:32:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5102 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5117 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="51 MC CO" b2="138 KV" b3="TR76 34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98098</SeqNum>
    <Name>DTX138.Blaine.T1&amp;T2</Name>
    <LastEdit Timestamp="2024-09-17T12:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAINE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAINE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLAINE" b2="138 KV" b3="BLA-FRA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLAINE" b2="138 KV" b3="BLA-ROA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLAINE" b2="138 KV" b3="BLAI-WES" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BLAINE" b2="138 KV" b3="CAPB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAINE" b2="138 KV" b3="C_CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLAINE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLAINE" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98100</SeqNum>
    <Name>DTX138.MCCook.TR79</Name>
    <LastEdit Timestamp="2026-01-12T11:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="C7-8 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="51 MC CO" b2="138 KV" b3="CAP7" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="51 MC CO" b2="138 KV" b3="CAP8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5103 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5107 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="51 MC CO" b2="138 KV" b3="TR79 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="TR84 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98103</SeqNum>
    <Name>DTX138.79Spaulding.TR72</Name>
    <LastEdit Timestamp="2025-04-01T15:30:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="138 KV" b3="L7903 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="138 KV" b3="L96002CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="79 SPAUL" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98110</SeqNum>
    <Name>DTX138.Skokie.TR71</Name>
    <LastEdit Timestamp="2024-10-03T15:30:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L8802 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L8803 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="88 SKOKI" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="TR81 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98112</SeqNum>
    <Name>DTX138.Skokie.TR79</Name>
    <LastEdit Timestamp="2024-10-03T15:31:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="C7-8CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="88 SKOKI" b2="138 KV" b3="CAP7" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="88 SKOKI" b2="138 KV" b3="CAP8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L8806 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L8810 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="88 SKOKI" b2="138 KV" b3="TR79 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="TR84 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98114</SeqNum>
    <Name>DTX138.ClevelandCliffs.C14010</Name>
    <LastEdit Timestamp="2026-02-10T09:42:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLEVELCL" b2="138 KV" b3="10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLEVELCL" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLEVELCL" b2="138 KV" b3="C14010LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98116</SeqNum>
    <Name>DTX138.ClevelandCliffs.C14020</Name>
    <LastEdit Timestamp="2026-02-10T09:42:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLEVELCL" b2="138 KV" b3="20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLEVELCL" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLEVELCL" b2="138 KV" b3="C14020LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98117</SeqNum>
    <Name>DTX230.WestWharton.BK1</Name>
    <LastEdit Timestamp="2025-12-01T13:34:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="230 KV" b3="1A3 GCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="230 KV" b3="31C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="34 KV" b3="BK1E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="34 KV" b3="BK1F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWHARTON" b2="230 KV" b3="BK3 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WWHARTON" b2="230 KV" b3="BK_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98118</SeqNum>
    <Name>DTX138.Celanese.TUP1 &amp; TUT1 &amp; TUP2</Name>
    <LastEdit Timestamp="2024-09-17T12:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CELANESE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELANESE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CELANESE" b2="138 KV" b3="CEL-PET1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NBLACKSB" b2="138 KV" b3="NBL-CEL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CELANESE" b2="138 KV" b3="TUP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CELANESE" b2="138 KV" b3="TUP2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CELANESE" b2="138 KV" b3="TUT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98119</SeqNum>
    <Name>230/138.EastDanville.T4 (Scntlz)</Name>
    <LastEdit Timestamp="2026-03-19T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EDANVILL" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDANVILL" b2="230 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EDANVILL" b2="138 KV" b3="X4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98121</SeqNum>
    <Name>138/34.ElectricJct.TR76</Name>
    <LastEdit Timestamp="2026-03-31T15:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="111 ELEC" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="C1-2CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="111 ELEC" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="L11105CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="111 ELEC" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="X" Type="XF" b1="111 ELEC" b2="138 KV" b3="TR76 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="34.5 KV" b3="TR76 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="TR81 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98122</SeqNum>
    <Name>DTX138.Beckjord.T11</Name>
    <LastEdit Timestamp="2024-10-02T14:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="08TBSCO1" b2="138 KV" b3="08T-PIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="801" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="804" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="805" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="810" />
      <ContingencyEquipment Action="L" Type="LN" b1="SILVERGR" b2="138 KV" b3="BEC-SIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98123</SeqNum>
    <Name>DTX138.ProspectHeights.TR71.spog 6-6</Name>
    <LastEdit Timestamp="2024-10-23T13:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="117 PROS" b2="138 KV" b3="11702 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="117 PROS" b2="138 KV" b3="11705 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="117 PROS" b2="138 KV" b3="C5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="C5-6CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="117 PROS" b2="138 KV" b3="C6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="L11702CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="L11705CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="117 PROS" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="117 PROS" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98126</SeqNum>
    <Name>DTX138.ProspectHeights.TR72</Name>
    <LastEdit Timestamp="2024-10-08T13:21:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="117 PROS" b2="138 KV" b3="38C3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="117 PROS" b2="138 KV" b3="38C4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="C3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="L11704CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="117 PROS" b2="138 KV" b3="SVC100" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="SVC100CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="117 PROS" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98127</SeqNum>
    <Name>L69.Lawrence-Ewing.U-723</Name>
    <LastEdit Timestamp="2024-09-17T12:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EWING" b2="69 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWING" b2="69 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="EWING" b2="69 KV" b3="EWI-LAW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="69 KV" b3="1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="69 KV" b3="9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98128</SeqNum>
    <Name>DTX138.Dresden.TR10</Name>
    <LastEdit Timestamp="2024-10-08T13:19:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="L1207 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="12 DRESD" b2="138 KV" b3="TR10 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="TR81 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98129</SeqNum>
    <Name>DTX138.ChryslerToledo.T1</Name>
    <LastEdit Timestamp="2024-09-26T16:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRYSLE2" b2="138 KV" b3="13290" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRYSLE2" b2="138 KV" b3="13291" />
      <ContingencyEquipment Action="L" Type="LN" b1="FSTSOLAR" b2="138 KV" b3="FST-CHR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHRYSLE2" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98130</SeqNum>
    <Name>DTX138.Dresden.ATR12</Name>
    <LastEdit Timestamp="2023-12-07T14:58:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="12 DRESD" b2="138 KV" b3="ATR12 04" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="L0903 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="138 KV" b3="L1206 CB" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="J390" b2="138 KV" b3="TR767734" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98134</SeqNum>
    <Name>DTX138.Concord.T2 &amp; T3</Name>
    <LastEdit Timestamp="2025-03-28T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONCORD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONCORD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONCORD" b2="138 KV" b3="BB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CONCORD" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONCORD" b2="138 KV" b3="CON-COU" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONCORD" b2="138 KV" b3="CON-DUN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONCORD" b2="138 KV" b3="CON-TWI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONCORD" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONCORD" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONCORD" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONCORD" b2="138 KV" b3="TR1-P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONCORD" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98139</SeqNum>
    <Name>138/34.DeerCreek.T2</Name>
    <LastEdit Timestamp="2025-12-26T13:10:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DEERCREE" b2="138 KV" b3="2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="DEERCREE" b2="34 KV" b3="2-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCREE" b2="138 KV" b3="AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCREE" b2="138 KV" b3="AL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCREE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DEERCREE" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCREE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCREE" b2="34 KV" b3="G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DEERCREE" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98140</SeqNum>
    <Name>DTX138.Delaware.T1</Name>
    <LastEdit Timestamp="2025-09-04T14:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DELAWAIM" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELAWAIM" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98141</SeqNum>
    <Name>DTX138.GolfMill.TR71</Name>
    <LastEdit Timestamp="2024-10-07T16:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="172 GOLF" b2="138 KV" b3="4610" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="L4610 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="172 GOLF" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="172 GOLF" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98142</SeqNum>
    <Name>DTX138.Delaware.T2</Name>
    <LastEdit Timestamp="2025-10-02T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DELAWAIM" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELAWAIM" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98143</SeqNum>
    <Name>DTX138.GolfMill.TR73</Name>
    <LastEdit Timestamp="2024-10-07T16:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="172 GOLF" b2="138 KV" b3="4611" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="L4611 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="172 GOLF" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="172 GOLF" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98144</SeqNum>
    <Name>DTX138.Dixie.TR5</Name>
    <LastEdit Timestamp="2025-06-26T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DIXIEFE" b2="138 KV" b3="B55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DIXIEFE" b2="138 KV" b3="B58" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DIXIEFE" b2="138 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98150</SeqNum>
    <Name>DTX115.DupontWaynesboro.T2</Name>
    <LastEdit Timestamp="2024-11-20T13:43:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPWAYNE" b2="115 KV" b3="106352" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPWAYNE" b2="115 KV" b3="14652" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOOMS4" b2="115 KV" b3="146A" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUPWAYNE" b2="115 KV" b3="DUP-SDRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPWAYNE" b2="115 KV" b3="SC152" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DUPWAYNE" b2="115 KV" b3="SC1P1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPWAYNE" b2="115 KV" b3="T122" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUPWAYNE" b2="115 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98152</SeqNum>
    <Name>DTX138.MCCook.TR72</Name>
    <LastEdit Timestamp="2024-05-15T10:56:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="51 MC CO" b2="138 KV" b3="5104 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="51 MC CO" b2="138 KV" b3="5105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="C7-8 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="51 MC CO" b2="138 KV" b3="CAP7" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="51 MC CO" b2="138 KV" b3="CAP8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5104 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5105 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="51 MC CO" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="51 MC CO" b2="345 KV" b3="TR82_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98154</SeqNum>
    <Name>DTX138.MCCook.TR73 + TR78</Name>
    <LastEdit Timestamp="2024-10-03T15:33:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5101 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="51 MC CO" b2="138 KV" b3="L5118 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="51 MC CO" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="51 MC CO" b2="138 KV" b3="TR78 34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98155</SeqNum>
    <Name>L138.Wayman-StullRun-GosneyHill</Name>
    <LastEdit Timestamp="2025-04-21T15:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOSNEYHI" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOSNEYHI" b2="138 KV" b3="GOS-STU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STULLRUN" b2="138 KV" b3="CONSOL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYMAN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="STULLRUN" b2="138 KV" b3="STU-WAY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98158</SeqNum>
    <Name>DTX138.EastLake.T599EL &amp; T500EL</Name>
    <LastEdit Timestamp="2026-02-10T13:03:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTLAKE" b2="138 KV" b3="500EL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTLAKE" b2="138 KV" b3="599EL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="345 KV" b3="B712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="345 KV" b3="B725" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B795" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G4SC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTLAKE" b2="24 KV" b3="LD50" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTLAKE" b2="18 KV" b3="LOAD410" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q4T" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="24 KV" b3="SC5" />
      <ContingencyEquipment Action="X" Type="XF" b1="EASTLAKE" b2="138 KV" b3="TR4" />
      <ContingencyEquipment Action="X" Type="XF" b1="EASTLAKE" b2="345 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98160</SeqNum>
    <Name>DTX138.EastWood.BK2</Name>
    <LastEdit Timestamp="2024-09-19T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="08BROWN" b2="138 KV" b3="08B-08E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTWOOD" b2="138 KV" b3="860" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTWOOD" b2="138 KV" b3="861" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTWOOD" b2="138 KV" b3="BK2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98161</SeqNum>
    <Name>DTX138.Skokie.TR72 + TR77</Name>
    <LastEdit Timestamp="2024-10-07T16:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="11416" b2="138 KV" b3="11416 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="88 SKOKI" b2="138 KV" b3="8805 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L11416CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L8805 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="88 SKOKI" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="88 SKOKI" b2="138 KV" b3="TR77 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="TR82 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="88 SKOKI" b2="138 KV" b3="TR82CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98162</SeqNum>
    <Name>DTX138.Skokie.TR73 + TR78</Name>
    <LastEdit Timestamp="2024-10-07T16:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="88 SKOKI" b2="138 KV" b3="8801 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="8809" b2="138 KV" b3="8809 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="C5-6CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="88 SKOKI" b2="138 KV" b3="CAP5" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="88 SKOKI" b2="138 KV" b3="CAP6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L8801 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="L8809 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="88 SKOKI" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="88 SKOKI" b2="138 KV" b3="TR78 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="88 SKOKI" b2="138 KV" b3="TR83 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="88 SKOKI" b2="138 KV" b3="TR83CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98166</SeqNum>
    <Name>138/69.Wooster.T2</Name>
    <LastEdit Timestamp="2026-01-28T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="WOOSTER" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WOOSTER" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOOSTER" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOOSTER" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOOSTER" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOOSTER" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOOSTER" b2="138 KV" b3="H014K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOOSTER" b2="138 KV" b3="H014K5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOOSTER" b2="138 KV" b3="I" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOOSTER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOOSTER" b2="138 KV" b3="T2_XF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOOSTER" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98167</SeqNum>
    <Name>DTX138.Eleipsic.TR1-ELE &amp; TR2-PRO</Name>
    <LastEdit Timestamp="2025-08-21T17:15:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELEIPSIC" b2="138 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELEIPSIC" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ELEIPSIC" b2="138 KV" b3="CAPAA" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELEIPSIC" b2="138 KV" b3="ELE-LAMM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELEIPSIC" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELEIPSIC" b2="138 KV" b3="TR1-ELE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELEIPSIC" b2="138 KV" b3="TR2-PRO" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELEIPSIC" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELEIPSIC" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98168</SeqNum>
    <Name>DTX138.Woodville.TR1</Name>
    <LastEdit Timestamp="2025-12-30T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVLTE" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVLTE" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODVLTE" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98171</SeqNum>
    <Name>DTX115.ErieWest.T2</Name>
    <LastEdit Timestamp="2025-04-15T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ERIEW" b2="115 KV" b3="2 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="115 KV" b3="B133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERIEW" b2="115 KV" b3="B145" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98172</SeqNum>
    <Name>138/69.WestMtVernon.TR1</Name>
    <LastEdit Timestamp="2025-09-30T20:44:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="WMTVERNO" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMTVERNO" b2="138 KV" b3="H001A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMTVERNO" b2="69 KV" b3="H001A5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMTVERNO" b2="69 KV" b3="H005F2" />
      <ContingencyEquipment Action="X" Type="XF" b1="WMTVERNO" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98173</SeqNum>
    <Name>115/35.EastTowanda.T2 </Name>
    <LastEdit Timestamp="2025-04-22T11:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ETOWANDA" b2="115 KV" b3="2TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B111" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="34.5 KV" b3="B2TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98174</SeqNum>
    <Name>DTX138.WestMedina.TR1</Name>
    <LastEdit Timestamp="2025-05-15T12:48:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WMEDINA" b2="138 KV" b3="15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMEDINA" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMEDINA" b2="138 KV" b3="B25" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WMEDINA" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WMEDINA" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98175</SeqNum>
    <Name>115/35.EastTowanda.T1</Name>
    <LastEdit Timestamp="2025-03-28T15:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ETOWANDA" b2="115 KV" b3="1TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B121" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="34.5 KV" b3="B1TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98176</SeqNum>
    <Name>DTX138.WestLancaster.T2</Name>
    <LastEdit Timestamp="2024-09-17T12:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WLANCAST" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLANCAST" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOCKING" b2="138 KV" b3="HOC-WLA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLANCAST" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLANCAST" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="L" Type="LN" b1="SBALTIMO" b2="138 KV" b3="SBA-WLA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SLANCAST" b2="138 KV" b3="SLA-WLA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WLANCAST" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98178</SeqNum>
    <Name>138/69/34.EastWooster.T2</Name>
    <LastEdit Timestamp="2025-10-10T12:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EWOOSTER" b2="138 KV" b3="2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="EWOOSTER" b2="69 KV" b3="2-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="EWOOSTER" b2="34.5 KV" b3="2-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWOOSTER" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EWOOSTER" b2="34.5 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EWOOSTER" b2="138 KV" b3="X2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98184</SeqNum>
    <Name>DTX115.FarmersValley.T2</Name>
    <LastEdit Timestamp="2025-01-09T14:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMERSV" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMERSV" b2="115 KV" b3="B26" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FARMERSV" b2="115 KV" b3="CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMERSV" b2="115 KV" b3="CS15" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMERSV" b2="115 KV" b3="FAR-PIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FARMERSV" b2="115 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98185</SeqNum>
    <Name>DTX138.WestCanton.T3</Name>
    <LastEdit Timestamp="2024-09-17T12:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="BB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WCANTON" b2="138 KV" b3="CAPB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILESAVE" b2="138 KV" b3="MIL-WCA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WCANTON" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="L" Type="LN" b1="WCANTON" b2="138 KV" b3="WCA-DAL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98187</SeqNum>
    <Name>DTX138.WestCanton.T1</Name>
    <LastEdit Timestamp="2025-08-26T17:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="JJ" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WCANTON" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WCANTON" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98189</SeqNum>
    <Name>DTX115.Geneva.T1</Name>
    <LastEdit Timestamp="2025-12-02T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GENEVA" b2="115 KV" b3="3TX115C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GENEVA" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKTAP" b2="115 KV" b3="FRN-GEN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GENEVA" b2="115 KV" b3="NO1 TX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GENEVA" b2="115 KV" b3="NO3 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GENEVA" b2="115 KV" b3="WAYNE CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98190</SeqNum>
    <Name>DTX138.Genoa.T2</Name>
    <LastEdit Timestamp="2024-09-26T16:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GENOA" b2="138 KV" b3="101N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GENOA" b2="138 KV" b3="102N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GENOA" b2="138 KV" b3="103N" />
      <ContingencyEquipment Action="L" Type="LN" b1="MALISZEW" b2="138 KV" b3="MAL-GEN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GENOA" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98193</SeqNum>
    <Name>L138.Allentown-8thStreet.2</Name>
    <LastEdit Timestamp="2024-10-14T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="8THST" b2="138 KV" b3="BUS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="8THST" b2="138 KV" b3="8TH-ALL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="CEAL2INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENTOW" b2="138 KV" b3="CEAL_2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLENTOW" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98194</SeqNum>
    <Name>L138.8thSt-CAllentwn-Sumner-SWhitehll-Wescsvlle.2</Name>
    <LastEdit Timestamp="2024-10-14T13:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="8THST" b2="138 KV" b3="8TH-CEA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="8THST" b2="138 KV" b3="BUS2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="8THST" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEALALL" b2="138 KV" b3="CEA-SUM2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CEALALL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUMNER" b2="138 KV" b3="SUM-SWH2" />
      <ContingencyEquipment Action="L" Type="LN" b1="S WHI" b2="138 KV" b3="SWH-WES2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="S WHI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUMNER" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WESCOSVI" b2="138 KV" b3="ALLE2INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESCOSVI" b2="138 KV" b3="ALLE_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98195</SeqNum>
    <Name>DTX138.Glenlyn.T2&amp;T9</Name>
    <LastEdit Timestamp="2025-12-19T11:53:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENLYN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GLENLYN" b2="138 KV" b3="CAP_BB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GLENLYN" b2="138 KV" b3="CAP_DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENLYN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENLYN" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENLYN" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLENLYN" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLENLYN" b2="138 KV" b3="T9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98196</SeqNum>
    <Name>DTX138.Desplains.TR72 &amp; TR77</Name>
    <LastEdit Timestamp="2024-10-09T11:13:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L4605 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L4610 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="46 DESPL" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="46 DESPL" b2="138 KV" b3="TR77 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="TR82 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98198</SeqNum>
    <Name>DTX138.Desplains.TR73 &amp; TR78</Name>
    <LastEdit Timestamp="2025-12-15T13:33:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="46 DESPL" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="CAP1-2CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="46 DESPL" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L11701CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L4607 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L83_CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="46 DESPL" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="46 DESPL" b2="138 KV" b3="TR78 34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98199</SeqNum>
    <Name>DTX138.Wayview.T1 &amp; T2</Name>
    <LastEdit Timestamp="2024-09-26T16:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELDENVI" b2="138 KV" b3="BEL-WAY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYVIEW" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYVIEW" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="PROMWAY" b2="138 KV" b3="PRO-WAY1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAYVIEW" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAYVIEW" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98202</SeqNum>
    <Name>DTX138.Wauseon.TR1 &amp; TR3</Name>
    <LastEdit Timestamp="2025-11-06T13:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUSEON" b2="138 KV" b3="B13415" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUSEON" b2="138 KV" b3="B32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUSEON" b2="138 KV" b3="B41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUSEON" b2="138 KV" b3="B51" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAUSEON" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAUSEON" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98203</SeqNum>
    <Name>DTX115.Grandview.T2</Name>
    <LastEdit Timestamp="2024-09-26T16:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRANDVIE" b2="115 KV" b3="2 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDVIE" b2="115 KV" b3="BSSEC115" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLARKSUM" b2="115 KV" b3="CLA-GRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDVIE" b2="115 KV" b3="ECLIPSE" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANDVIE" b2="115 KV" b3="GRA-TIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDVIE" b2="115 KV" b3="TITUSVIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98205</SeqNum>
    <Name>138/69.Wagenhals.T2</Name>
    <LastEdit Timestamp="2025-08-29T12:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WAGENHAL" b2="138 KV" b3="2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAGENHAL" b2="69 KV" b3="2-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAGENHAL" b2="23 KV" b3="2-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAGENHAL" b2="23 KV" b3="DISTLOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAGENHAL" b2="69 KV" b3="MAHONING" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="69 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="69 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="69 KV" b3="T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98207</SeqNum>
    <Name>138/69.Wagenhals.T3 + DTX138.T1</Name>
    <LastEdit Timestamp="2025-08-29T12:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="WAGENHAL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="69 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="69 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAGENHAL" b2="69 KV" b3="S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAGENHAL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAGENHAL" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAGENHAL" b2="69 KV" b3="WLOUISVI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98210</SeqNum>
    <Name>DTX230.Greystone.T2 &amp; T4</Name>
    <LastEdit Timestamp="2024-08-20T08:57:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREYSTON" b2="230 KV" b3="B6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREYSTON" b2="230 KV" b3="BK 2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREYSTON" b2="230 KV" b3="BK 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREYSTON" b2="230 KV" b3="GRE-WHIJ" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREYSTON" b2="230 KV" b3="GRE-WWH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREYSTON" b2="230 KV" b3="J1024 GC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98211</SeqNum>
    <Name>DTX138.Torrey.T2</Name>
    <LastEdit Timestamp="2025-10-20T10:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TORREY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORREY" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TORREY" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORREY" b2="138 KV" b3="W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98213</SeqNum>
    <Name>DTX115.Tiffany.T2</Name>
    <LastEdit Timestamp="2026-05-13T16:28:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIFFANY" b2="115 KV" b3="#2 TX" />
      <ContingencyEquipment Action="L" Type="LN" b1="TIFFANY" b2="115 KV" b3="TIF-WAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINER" b2="115 KV" b3="B41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINER" b2="115 KV" b3="B53" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98218</SeqNum>
    <Name>DTX138.Talmadge.TR1 </Name>
    <LastEdit Timestamp="2024-11-27T10:39:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TALWGATE" b2="138 KV" b3="B40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TALWGATE" b2="138 KV" b3="B50" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TALWGATE" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98220</SeqNum>
    <Name>DTX138.Sunnyside.T4</Name>
    <LastEdit Timestamp="2024-09-26T16:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNNYSOP" b2="138 KV" b3="BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNNYSOP" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SUNNYSOP" b2="138 KV" b3="CAPB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARROLLT" b2="138 KV" b3="CAR-SUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNNYSOP" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNNYSOP" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="L" Type="LN" b1="WARNERSS" b2="138 KV" b3="SUN-WAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNNYSOP" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98222</SeqNum>
    <Name>DTX138.Sunnyside.T5&amp;T6</Name>
    <LastEdit Timestamp="2025-07-11T12:39:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNNYSOP" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNNYSOP" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNNYSOP" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNNYSOP" b2="138 KV" b3="T5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNNYSOP" b2="138 KV" b3="T6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98223</SeqNum>
    <Name>DTX138.Hernshaw.RAVEN</Name>
    <LastEdit Timestamp="2025-02-11T08:31:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HERNSHAW" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERNSHAW" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERNSHAW" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERNSHAW" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIELDCRE" b2="138 KV" b3="FIE-HERN" />
      <ContingencyEquipment Action="L" Type="LN" b1="HERNSHAW" b2="138 KV" b3="HER-RUT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HERNSHAW" b2="138 KV" b3="RAVEN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98224</SeqNum>
    <Name>L345.NorthAve-NewarkAirport.S-3419</Name>
    <LastEdit Timestamp="2024-10-03T15:16:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHAV" b2="345 KV" b3="4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHAV" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWRKARPT" b2="345 KV" b3="4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWRKARPT" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="NWRKARPT" b2="345 KV" b3="NEW-NOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98225</SeqNum>
    <Name>DTX138.Sundial.T1</Name>
    <LastEdit Timestamp="2026-03-26T14:03:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNDIAL" b2="138 KV" b3="M CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNDIAL" b2="138 KV" b3="P CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNDIAL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98227</SeqNum>
    <Name>DTX115.HighRidge.ONE &amp; T33-3 &amp; T33-2</Name>
    <LastEdit Timestamp="2024-09-25T14:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HIGHRIDG" b2="230 KV" b3="230-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="115 KV" b3="230-1LS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIGHRIDG" b2="115 KV" b3="33-2LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIGHRIDG" b2="115 KV" b3="33-3LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="115 KV" b3="BRI" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HIGHRIDG" b2="115 KV" b3="BRIGHDAM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIGHRIDG" b2="115 KV" b3="ONE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98228</SeqNum>
    <Name>L345.NorthAve-NewarkAirport.R-3418</Name>
    <LastEdit Timestamp="2024-05-31T15:05:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHAV" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHAV" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWRKARPT" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWRKARPT" b2="345 KV" b3="1-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="NWRKARPT" b2="345 KV" b3="NEW-NOR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98229</SeqNum>
    <Name>DTX138.StClair.T2</Name>
    <LastEdit Timestamp="2024-09-25T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="STCLAIR2" b2="138 KV" b3="CAP6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="FF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STCLAIR2" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98230</SeqNum>
    <Name>DTX115.HighRidge.TWO &amp; T33-1</Name>
    <LastEdit Timestamp="2024-09-25T14:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HIGHRIDG" b2="230 KV" b3="230-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHRIDG" b2="115 KV" b3="230-2LS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIGHRIDG" b2="115 KV" b3="33-1LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIGHRIDG" b2="115 KV" b3="TWO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98233</SeqNum>
    <Name>L230.Mercer-Trenton.B-2202</Name>
    <LastEdit Timestamp="2024-10-03T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCER" b2="230 KV" b3="SECT1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCER" b2="230 KV" b3="SECT5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERCER" b2="230 KV" b3="MER-TRE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98234</SeqNum>
    <Name>DTX115.Hilltop.T2</Name>
    <LastEdit Timestamp="2025-01-03T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILLTOP" b2="115 KV" b3="2 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTOP" b2="115 KV" b3="B56" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTOP" b2="115 KV" b3="B59" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98236</SeqNum>
    <Name>DTX138.Hinton.T1</Name>
    <LastEdit Timestamp="2026-01-28T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HINTON" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINTON" b2="138 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINTON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HINTON" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HINTON" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98237</SeqNum>
    <Name>DTX115.Springboro.T1</Name>
    <LastEdit Timestamp="2025-12-23T10:34:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRINGBO" b2="115 KV" b3="1 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGBO" b2="115 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGBO" b2="115 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98241</SeqNum>
    <Name>DTX115.Hooversville.T1</Name>
    <LastEdit Timestamp="2025-05-15T09:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOOVERSV" b2="115 KV" b3="1 TX 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOOVERSV" b2="115 KV" b3="B35" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98242</SeqNum>
    <Name>DTX138.SouthPoint.T2 &amp; T6</Name>
    <LastEdit Timestamp="2024-09-25T15:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOINT" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOINT" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENOVA" b2="138 KV" b3="KEN-SPO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLBROO" b2="138 KV" b3="MIL-SPO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPOINT" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPOINT" b2="138 KV" b3="T6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOINT" b2="138 KV" b3="V" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOINT" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98243</SeqNum>
    <Name>138/69/34.SouthPoint.T4</Name>
    <LastEdit Timestamp="2026-01-02T11:12:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SPOINT" b2="138 KV" b3="4-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPOINT" b2="69 KV" b3="4-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPOINT" b2="34.5 KV" b3="4-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOINT" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SPOINT" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOINT" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOINT" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOINT" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOINT" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOINT" b2="34.5 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPOINT" b2="34.5 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98244</SeqNum>
    <Name>DTX115.Hooversville.T2</Name>
    <LastEdit Timestamp="2025-05-22T13:29:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOOVERSV" b2="115 KV" b3="2 TX 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOOVERSV" b2="115 KV" b3="B29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOOVERSV" b2="115 KV" b3="B41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOOVERSV" b2="115 KV" b3="SOMERSSF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98245</SeqNum>
    <Name>DTX138.SoftShell.T1</Name>
    <LastEdit Timestamp="2024-09-25T15:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BONNYMAN" b2="138 KV" b3="BON-SOF" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOFTSHEL" b2="138 KV" b3="CON-SOF" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOFTSHEL" b2="138 KV" b3="HAR-SOF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOFTSHEL" b2="138 KV" b3="J CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOFTSHEL" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOFTSHEL" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOFTSHEL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98246</SeqNum>
    <Name>DTX138.Horizon.T1 (FE)</Name>
    <LastEdit Timestamp="2025-09-24T12:09:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON1" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON1" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HORIZON1" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98249</SeqNum>
    <Name>DTX138.Horizon.T2 (FE)</Name>
    <LastEdit Timestamp="2025-09-24T12:10:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON1" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON1" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HORIZON1" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98251</SeqNum>
    <Name>DTX138.HummelCreek.T1 &amp; T2</Name>
    <LastEdit Timestamp="2025-08-26T17:57:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELCR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELCR" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELCR" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUMMELCR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUMMELCR" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98253</SeqNum>
    <Name>DTX115.Shelocta.T1</Name>
    <LastEdit Timestamp="2025-07-11T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHELOCTA" b2="115 KV" b3="1 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELOCTA" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELOCTA" b2="115 KV" b3="B52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELOCTA" b2="115 KV" b3="NO2TX115" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98254</SeqNum>
    <Name>DTX138.Shelby.T2</Name>
    <LastEdit Timestamp="2024-09-25T15:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBYOP" b2="138 KV" b3="GENCB1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SHELBYOP" b2="138 KV" b3="GENDUMMY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBYOP" b2="138 KV" b3="GH1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBYOP" b2="138 KV" b3="GH2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOWARD2" b2="138 KV" b3="HOW-SHE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHELBYOP" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98255</SeqNum>
    <Name>DTX138.Jackman.T1</Name>
    <LastEdit Timestamp="2025-08-11T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKMAN" b2="138 KV" b3="3329" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKMAN" b2="138 KV" b3="3333" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKMAN" b2="138 KV" b3="B13328" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKMAN" b2="138 KV" b3="B13331" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="JACKMAN" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKMAN" b2="138 KV" b3="CS01" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JACKMAN" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98256</SeqNum>
    <Name>138/69.SharpRoad.TR1</Name>
    <LastEdit Timestamp="2025-10-15T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARPROA" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHARPROA" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHARPROA" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98257</SeqNum>
    <Name>DTX138.SouthBluefield.T1</Name>
    <LastEdit Timestamp="2026-05-08T15:19:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SBLUEFIE" b2="138 KV" b3="AA" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEFIEL" b2="138 KV" b3="BLU-SBL1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SBLUEFIE" b2="138 KV" b3="CAPAA" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERIVERMO" b2="138 KV" b3="ERI-SBL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBLUEFIE" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBLUEFIE" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="L" Type="LN" b1="SBLUEFIE" b2="138 KV" b3="SBL-TOW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBLUEFIE" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SBLUEFIE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98262</SeqNum>
    <Name>DTX138.SouthBaltimore.T1</Name>
    <LastEdit Timestamp="2024-09-25T15:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SBALTIMO" b2="138 KV" b3="A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBALTIMO" b2="138 KV" b3="B CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="SBALTIMO" b2="138 KV" b3="SBA-WLA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SBALTIMO" b2="138 KV" b3="SBA-WMI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SBALTIMO" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98263</SeqNum>
    <Name>DTX115.Saxton.T6</Name>
    <LastEdit Timestamp="2025-04-25T16:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SAXTON" b2="115 KV" b3="6 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAXTON" b2="115 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAXTON" b2="115 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAXTON" b2="115 KV" b3="B42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAXTON" b2="115 KV" b3="B50" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SAXTON" b2="115 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAXTON" b2="115 KV" b3="CS1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CURRYVIL" b2="115 KV" b3="CUR-SAX" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAXTON" b2="115 KV" b3="SAX-SNA" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAXTON" b2="115 KV" b3="SAX-THR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98265</SeqNum>
    <Name>DTX138.Saltville.T2&amp;T5</Name>
    <LastEdit Timestamp="2025-07-31T14:03:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTVILL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTVILL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SALTVILL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SALTVILL" b2="138 KV" b3="T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTVILL" b2="138 KV" b3="U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTVILL" b2="138 KV" b3="V" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98268</SeqNum>
    <Name>138/69.Saltville.T1</Name>
    <LastEdit Timestamp="2025-08-29T12:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SALTVILL" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="SALTVILL" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SALTVILL" b2="34.5 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTVILL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SALTVILL" b2="34.5 KV" b3="DISTLOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTVILL" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTVILL" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTVILL" b2="138 KV" b3="U" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98270</SeqNum>
    <Name>DTX138.SouthAbingdon.T1</Name>
    <LastEdit Timestamp="2024-09-26T16:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ABINGDON" b2="138 KV" b3="ABI-SAB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SABINGDN" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SABINGDN" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SABINGDN" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="L" Type="LN" b1="SABINGDN" b2="138 KV" b3="SAB-SPR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SABINGDN" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98273</SeqNum>
    <Name>DTX138.Krendale.T61</Name>
    <LastEdit Timestamp="2024-09-25T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KRENDALE" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KRENDALE" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEISTERS" b2="138 KV" b3="KEI-KRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KRENDALE" b2="138 KV" b3="KEISTERS" />
      <ContingencyEquipment Action="L" Type="LN" b1="KRENDALE" b2="138 KV" b3="KRE-SHA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KRENDALE" b2="138 KV" b3="T61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98276</SeqNum>
    <Name>DTX115.RoundTop.1B71 &amp; 1B72</Name>
    <LastEdit Timestamp="2026-05-28T14:37:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROUNDTOP" b2="115 KV" b3="1B71" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROUNDTOP" b2="115 KV" b3="1B72" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTOP" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTOP" b2="115 KV" b3="B97372" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTOP" b2="115 KV" b3="B97572" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTOP" b2="115 KV" b3="B98172" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ROUNDTOP" b2="115 KV" b3="CAP2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROUNDTOP" b2="115 KV" b3="STATCOM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98277</SeqNum>
    <Name>345/138.MiamiFort.T9</Name>
    <LastEdit Timestamp="2024-09-26T14:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1401" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1418" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="806" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIAMIFOR" b2="345 KV" b3="9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="928" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98278</SeqNum>
    <Name>345/138.MiamiFort.T10</Name>
    <LastEdit Timestamp="2024-09-26T14:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MIAMIFOR" b2="345 KV" b3="10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1409" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1413" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="908" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="931" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98279</SeqNum>
    <Name>L345.TannersCreek-MiamiFort</Name>
    <LastEdit Timestamp="2025-05-16T12:59:00" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1401" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1403" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TANNERSC" b2="345 KV" b3="TAN-MIA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98280</SeqNum>
    <Name>138/34.Rockhill.T3</Name>
    <LastEdit Timestamp="2024-09-24T16:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKHILL" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKHILL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKHILL" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="FORD" b2="138 KV" b3="FOR-ROC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKHILL" b2="34 KV" b3="M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKHILL" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98282</SeqNum>
    <Name>DTX138.Riverview.T1</Name>
    <LastEdit Timestamp="2024-09-25T15:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIE" b2="138 KV" b3="634" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIE" b2="138 KV" b3="636" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIE" b2="138 KV" b3="644" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKEM" b2="138 KV" b3="ELK-RIV" />
      <ContingencyEquipment Action="L" Type="LN" b1="GORSUCH" b2="138 KV" b3="GOR-RIV" />
      <ContingencyEquipment Action="L" Type="LN" b1="NVIENNA" b2="138 KV" b3="NVI-RIV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERVIE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98286</SeqNum>
    <Name>DTX115.Lenox.T1</Name>
    <LastEdit Timestamp="2024-12-18T12:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LENOX" b2="115 KV" b3="1 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LENOX" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="LENOX" b2="115 KV" b3="LEN-MAC" />
      <ContingencyEquipment Action="L" Type="LN" b1="LENOX" b2="115 KV" b3="LEN-NME" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LENOX" b2="115 KV" b3="N MESHOP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98289</SeqNum>
    <Name>DTX138.Riverside.T1</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSIM" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSIM" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSIM" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERSIM" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98292</SeqNum>
    <Name>DTX138.Lincoln(AEP).T3</Name>
    <LastEdit Timestamp="2025-05-12T16:04:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN2" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINCOLN2" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN2" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98293</SeqNum>
    <Name>L230.Brambleton-PolandRoad.2183</Name>
    <LastEdit Timestamp="2025-10-20T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="21722183" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="218302" />
      <ContingencyEquipment Action="L" Type="LN" b1="POLANDRD" b2="230 KV" b3="2183A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POLANDRD" b2="230 KV" b3="218322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POLANDRD" b2="230 KV" b3="H3T2183" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98295</SeqNum>
    <Name>L138.Wilson-WestMifflin.Z-14</Name>
    <LastEdit Timestamp="2024-10-01T16:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE7-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON" b2="138 KV" b3="TIE8-7" />
      <ContingencyEquipment Action="L" Type="LN" b1="WILSON" b2="138 KV" b3="WIL-WMI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMIFFLIN" b2="138 KV" b3="WILSON" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98296</SeqNum>
    <Name>L138.USSClairton-Dravosburg.Z-15</Name>
    <LastEdit Timestamp="2024-10-22T17:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="138 KV" b3="Z-15" />
      <ContingencyEquipment Action="L" Type="LN" b1="DRAVOSBU" b2="138 KV" b3="DRA-USS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="USSCLAIR" b2="138 KV" b3="Z-15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98297</SeqNum>
    <Name>DTX138.Lincoln(FE).T73</Name>
    <LastEdit Timestamp="2024-09-25T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLN5" b2="138 KV" b3="LIN-LLO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLN5" b2="138 KV" b3="LIN-LLO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN5" b2="138 KV" b3="SWR392" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN5" b2="138 KV" b3="SWR492" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINCOLN5" b2="138 KV" b3="TR73" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98298</SeqNum>
    <Name>DTX138.Logan.T4</Name>
    <LastEdit Timestamp="2024-09-25T14:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGAN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGAN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LOGAN" b2="138 KV" b3="CAPA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGAN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGAN" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOGAN" b2="138 KV" b3="LOG-MUD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOGAN" b2="138 KV" b3="LOG-PIN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOGAN" b2="138 KV" b3="LOG-RUM1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOGAN" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98300</SeqNum>
    <Name>DTX138.LongReach.UNIONCAR</Name>
    <LastEdit Timestamp="2025-08-25T12:44:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGREAC" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGREAC" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LONGREAC" b2="138 KV" b3="UNIONCAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98316</SeqNum>
    <Name>DTX138.MiamiFort.TB16</Name>
    <LastEdit Timestamp="2025-01-09T14:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="805" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="905" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIAMIFOR" b2="138 KV" b3="TB16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98320</SeqNum>
    <Name>DTX138.Moreland.T1</Name>
    <LastEdit Timestamp="2025-08-22T15:36:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORELAND" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORELAND" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MORELAND" b2="138 KV" b3="MORELAND" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98332</SeqNum>
    <Name>138/69.Ridgeway.TR2</Name>
    <LastEdit Timestamp="2025-07-25T15:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGEWAY" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGEWAY" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIDGEWAY" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RIDGEWAY" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98335</SeqNum>
    <Name>DTX138.OakMound.T1</Name>
    <LastEdit Timestamp="2024-09-25T14:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKMOUND" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENFALL" b2="138 KV" b3="GLE-OAK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKMOUND" b2="138 KV" b3="GLEN" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKMOUND" b2="138 KV" b3="OAK-RID" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKMOUND" b2="138 KV" b3="OAK-WAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKMOUND" b2="138 KV" b3="RIDER" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKMOUND" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKMOUND" b2="138 KV" b3="WALDO1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98338</SeqNum>
    <Name>DTX138.OakMound.T2</Name>
    <LastEdit Timestamp="2024-09-25T14:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKMOUND" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKMOUND" b2="138 KV" b3="OAK-QUI" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKMOUND" b2="138 KV" b3="OAK-WAL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKMOUND" b2="138 KV" b3="QUIETDEL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKMOUND" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKMOUND" b2="138 KV" b3="WALDO2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98339</SeqNum>
    <Name>DTX138.Osage.T1</Name>
    <LastEdit Timestamp="2024-10-24T14:21:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OSAGE" b2="138 KV" b3="502JCT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSAGE" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSAGE" b2="138 KV" b3="COLLINSF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSAGE" b2="138 KV" b3="MEA CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OSAGE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98340</SeqNum>
    <Name>DTX138.Osage.T2</Name>
    <LastEdit Timestamp="2024-09-25T15:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="502JCT" b2="138 KV" b3="502-OSA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSAGE" b2="138 KV" b3="502JCT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSAGE" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="OSAGE" b2="138 KV" b3="OSA-WOV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OSAGE" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSAGE" b2="138 KV" b3="WESTOVER" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98348</SeqNum>
    <Name>DTX138.Peakcreek.T1 &amp; T2</Name>
    <LastEdit Timestamp="2024-09-25T15:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEAKCREE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEAKCREE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSONS" b2="138 KV" b3="JAC-PEA1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PEAKCREE" b2="138 KV" b3="PEA-WES" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEAKCREE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEAKCREE" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98368</SeqNum>
    <Name>DTX138.NewLiberty.T3 &amp; T4</Name>
    <LastEdit Timestamp="2025-11-17T12:16:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLIBER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLIBER" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWLIBER" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWLIBER" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLIBER" b2="138 KV" b3="XT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98370</SeqNum>
    <Name>DTX345.Mansfield.TR1</Name>
    <LastEdit Timestamp="2024-09-25T15:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="46" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="57" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFIEL" b2="345 KV" b3="B151" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MANSFIEL" b2="345 KV" b3="LDTR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98371</SeqNum>
    <Name>DTX115.Pleasureville.1BANK &amp; 2BANK &amp; 4BANK</Name>
    <LastEdit Timestamp="2024-09-25T14:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLVL ME" b2="115 KV" b3="1BANK" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLVL ME" b2="115 KV" b3="2BANK" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLVL ME" b2="115 KV" b3="4BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLVL ME" b2="115 KV" b3="97172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLVL ME" b2="115 KV" b3="98372" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLVL ME" b2="115 KV" b3="98672" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PLVL ME" b2="115 KV" b3="CAP 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="CATTRACT" b2="115 KV" b3="CAT-PLV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLVL ME" b2="115 KV" b3="CS6" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARLEY D" b2="115 KV" b3="HAR-PLV" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTROSE" b2="115 KV" b3="MTR-PLV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98405</SeqNum>
    <Name>138/34.Lakeview.TR4</Name>
    <LastEdit Timestamp="2024-09-24T16:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKVEW" b2="138 KV" b3="142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKVEW" b2="138 KV" b3="145" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKVEW" b2="34 KV" b3="B15" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAKVEW" b2="138 KV" b3="M8" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAKVEW" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98406</SeqNum>
    <Name>138/34.Mckinley.T2</Name>
    <LastEdit Timestamp="2024-06-10T15:37:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MCKINLEY" b2="138 KV" b3="2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="MCKINLEY" b2="34 KV" b3="2-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCKINLEY" b2="34 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCKINLEY" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98416</SeqNum>
    <Name>L230.Susquehanna-Palooka.2</Name>
    <LastEdit Timestamp="2025-01-06T16:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PALOOKA" b2="230 KV" b3="JEN-SUS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PALOOKA" b2="230 KV" b3="PAL-SUS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALOOKA" b2="230 KV" b3="SUSQ2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="PALO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="PALO2T21" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98426</SeqNum>
    <Name>230/69.Jenkins.T2</Name>
    <LastEdit Timestamp="2024-09-30T13:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="JENKINS" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="230 KV" b3="TRAN2E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="230 KV" b3="TRAN2W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98436</SeqNum>
    <Name>L138.Strawton-Makahoy</Name>
    <LastEdit Timestamp="2024-10-22T17:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAKAHOY" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAKAHOY" b2="138 KV" b3="K1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRAWTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRAWTON" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAKAHOY" b2="138 KV" b3="MAK-STR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98446</SeqNum>
    <Name>L138.Pendleton-Rosehill-Linwood-Makahoy</Name>
    <LastEdit Timestamp="2024-10-22T16:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LINWOOD2" b2="138 KV" b3="LIN-ROS1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINWOOD2" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAKAHOY" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAKAHOY" b2="138 KV" b3="K1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINWOOD2" b2="138 KV" b3="LIN-MAK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENDLETO" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENDLETO" b2="138 KV" b3="PEN-ROS1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROSEHILL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98456</SeqNum>
    <Name>L138.SouthElwood-Makahoy</Name>
    <LastEdit Timestamp="2025-12-26T13:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAKAHOY" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAKAHOY" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAKAHOY" b2="138 KV" b3="MAK-SEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SELWOOD" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SELWOOD" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SELWOOD" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98466</SeqNum>
    <Name>L230.Ironwood-NorthLebanon</Name>
    <LastEdit Timestamp="2024-10-23T08:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONWOOD" b2="230 KV" b3="B52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONWOOD" b2="230 KV" b3="B53" />
      <ContingencyEquipment Action="L" Type="LN" b1="IRONWOOD" b2="230 KV" b3="IRO-NLE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEBNON" b2="230 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEBNON" b2="230 KV" b3="B53" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98486</SeqNum>
    <Name>Kearny.12CT.1-4</Name>
    <LastEdit Timestamp="2024-09-30T13:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEARNY" b2="230 KV" b3="NO 12XF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEARNY" b2="13 KV" b3="UN121" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEARNY" b2="13 KV" b3="UN122" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEARNY" b2="13 KV" b3="UN123" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEARNY" b2="13 KV" b3="UN124" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98506</SeqNum>
    <Name>L230.Essex-KearnySub-Kearny.R-2296</Name>
    <LastEdit Timestamp="2024-10-02T14:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="1-11CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="11-12CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEARNYSB" b2="230 KV" b3="ESS-KSBR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="15-16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="2-16" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEARNY" b2="230 KV" b3="KEA-KSBR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEARNYSB" b2="230 KV" b3="T-20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98516</SeqNum>
    <Name>DTX138.GolfMill.TR72</Name>
    <LastEdit Timestamp="2024-10-08T13:20:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="L8802 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="172 GOLF" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98526</SeqNum>
    <Name>DTX138.GolfMill.TR74</Name>
    <LastEdit Timestamp="2024-10-08T13:20:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="172 GOLF" b2="138 KV" b3="L8801 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="172 GOLF" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98536</SeqNum>
    <Name>345/138.WestMillersport.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-25T14:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WMILLERS" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WMILLERS" b2="345 KV" b3="X1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98546</SeqNum>
    <Name>345/138.WestMillersport.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-25T14:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WMILLERS" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="138 KV" b3="A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILLERS" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WMILLERS" b2="345 KV" b3="X2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98577</SeqNum>
    <Name>L345.Monroe-Wayne(DET)</Name>
    <LastEdit Timestamp="2025-04-18T17:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONROE" b2="345 KV" b3="CM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONROE" b2="345 KV" b3="CT" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONROE" b2="345 KV" b3="MON-WAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE2" b2="345 KV" b3="EF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE2" b2="345 KV" b3="EM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98607</SeqNum>
    <Name>L345.Faraday-Arlond</Name>
    <LastEdit Timestamp="2025-10-20T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARLD" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARLD" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARLD" b2="345 KV" b3="ARL-FARA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARADAY" b2="345 KV" b3="V23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARADAY" b2="345 KV" b3="V25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98637</SeqNum>
    <Name>230/115.Hathaway.TX2</Name>
    <LastEdit Timestamp="2024-09-30T13:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="230 KV" b3="H202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="115 KV" b3="L202" />
      <ContingencyEquipment Action="X" Type="XF" b1="HATHAWAY" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98700</SeqNum>
    <Name>L69.Midway-LewesRea-FivePoints.6766</Name>
    <LastEdit Timestamp="2024-09-30T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FIVEPTS" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIVEPTS" b2="69 KV" b3="FIV-LEW" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEWESREA" b2="69 KV" b3="LEW-MID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWESREA" b2="69 KV" b3="REATAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAY" b2="69 KV" b3="62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98710</SeqNum>
    <Name>138/26.Athenia.132-4</Name>
    <LastEdit Timestamp="2024-09-30T13:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ATHENIA" b2="138 KV" b3="132-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="132-4SF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98801</SeqNum>
    <Name>RAS.500/161.Volunteer.T1 + BusTie (TVA)</Name>
    <LastEdit Timestamp="2024-12-17T16:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VOLUNTE" b2="161 KV" b3="1064" />
      <ContingencyEquipment Action="CL" Type="CB" b1="VOLUNTE" b2="161 KV" b3="1074" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VOLUNTE" b2="500 KV" b3="5034" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VOLUNTE" b2="500 KV" b3="5038" />
      <ContingencyEquipment Action="X" Type="XF" b1="VOLUNTE" b2="500 KV" b3="XFRMR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98811</SeqNum>
    <Name>RAS.500/161.Volunteer.T2 + BusTie (TVA)</Name>
    <LastEdit Timestamp="2024-12-18T15:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="VOLUNTE" b2="161 KV" b3="1074" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VOLUNTE" b2="161 KV" b3="1084" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VOLUNTE" b2="500 KV" b3="5074" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VOLUNTE" b2="500 KV" b3="5078" />
      <ContingencyEquipment Action="X" Type="XF" b1="VOLUNTE" b2="500 KV" b3="XFRMR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98822</SeqNum>
    <Name>L230.VintHill-Wheeler.2174</Name>
    <LastEdit Timestamp="2024-09-30T14:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VINTHILL" b2="230 KV" b3="21012174" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINTHILL" b2="230 KV" b3="21632174" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEELER" b2="230 KV" b3="21612174" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEELER" b2="230 KV" b3="21742182" />
      <ContingencyEquipment Action="L" Type="LN" b1="WHEELER" b2="230 KV" b3="2174A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98832</SeqNum>
    <Name>L230.Bremo-Buckingham-Farmville.298</Name>
    <LastEdit Timestamp="2025-12-08T14:31:00" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="230 KV" b3="29822" />
      <ContingencyEquipment Action="L" Type="LN" b1="BREMO4" b2="230 KV" b3="298A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="230 KV" b3="H722" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKNGHM" b2="230 KV" b3="298B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BUCKNGHM" b2="35 KV" b3="BUCKN2SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BUCKNGHM" b2="35 KV" b3="BUCKNMSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUCKNGHM" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUCKNGHM" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUCKNGHM" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUCKNGHM" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="230 KV" b3="235T298" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="230 KV" b3="H532" />
      <ContingencyEquipment Action="X" Type="XF" b1="FARMVILL" b2="230 KV" b3="TX6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FARMVILL" b2="35 KV" b3="TX6LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98842</SeqNum>
    <Name>DTX345.NorthAve.T10</Name>
    <LastEdit Timestamp="2024-10-03T15:29:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHAV" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHAV" b2="345 KV" b3="3-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="NORTHAV" b2="345 KV" b3="T-10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NORTHAV" b2="13 KV" b3="T10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98852</SeqNum>
    <Name>DTX345.NorthAve.T20</Name>
    <LastEdit Timestamp="2024-10-03T15:29:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHAV" b2="345 KV" b3="1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHAV" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="X" Type="XF" b1="NORTHAV" b2="345 KV" b3="T-20" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NORTHAV" b2="13 KV" b3="T20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98862</SeqNum>
    <Name>230/115.Bremo.T7</Name>
    <LastEdit Timestamp="2026-01-06T11:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="230 KV" b3="H722" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="115 KV" b3="L722" />
      <ContingencyEquipment Action="X" Type="XF" b1="BREMO4" b2="230 KV" b3="TX7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98883</SeqNum>
    <Name>138/69.BuckleyRoad.TR1</Name>
    <LastEdit Timestamp="2024-10-02T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKLEYR" b2="138 KV" b3="CB-D" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUCKLEYR" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98904</SeqNum>
    <Name>115/35.NorthBangor.TX1</Name>
    <LastEdit Timestamp="2024-10-02T14:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COLUMBJC" b2="35 KV" b3="LOAD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NBANGOR" b2="115 KV" b3="1BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBANGOR" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBANGOR" b2="115 KV" b3="B5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NBANGOR" b2="35 KV" b3="BUS4 LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLUMBJC" b2="35 KV" b3="COL-NBAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBANGOR" b2="35 KV" b3="T-22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98926</SeqNum>
    <Name>L138.Athenia-EastRutherford.S-1345</Name>
    <LastEdit Timestamp="2024-11-13T15:01:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="138 KV" b3="2-12" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATHENIA" b2="138 KV" b3="ATH-ERU" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ERUTHERF" b2="138 KV" b3="132-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ERUTHERF" b2="138 KV" b3="132-2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERUTHERF" b2="138 KV" b3="132-4CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERUTHERF" b2="138 KV" b3="SECT1-5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ERUTHERF" b2="138 KV" b3="T1020XFR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ERUTHERF" b2="138 KV" b3="T20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>98927</SeqNum>
    <Name>L765.Greentown-Reynolds + Reynolds.T3</Name>
    <LastEdit Timestamp="2026-05-08T11:46:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GREENTO2" b2="765 KV" b3="GRE-REY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="765 KV" b3="U1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="765 KV" b3="U2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="30-XF3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="765 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="X" Type="XF" b1="REYNOLD2" b2="765 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="765 KV" b3="XF3BKR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="XF3CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99008</SeqNum>
    <Name>L138.Groton-Hayes</Name>
    <LastEdit Timestamp="2025-04-14T13:08:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GROTON" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GROTON" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GROTON" b2="138 KV" b3="GRO-HAY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="138 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="138 KV" b3="B27" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99009</SeqNum>
    <Name>L138.Groton-WestFremont</Name>
    <LastEdit Timestamp="2025-02-28T12:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GROTON" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GROTON" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="GROTON" b2="138 KV" b3="GRO-WFR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99020</SeqNum>
    <Name>L69.Galdys-StoneMillSS.35</Name>
    <LastEdit Timestamp="2024-10-02T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GLADYSDP" b2="69 KV" b3="35A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STNMLSSW" b2="69 KV" b3="SB3572" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99021</SeqNum>
    <Name>L138.Edison-CreekWalker</Name>
    <LastEdit Timestamp="2026-04-24T08:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CREEKWLK" b2="138 KV" b3="CRE-EDIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CREEKWLK" b2="138 KV" b3="M004D5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CREEKWLK" b2="138 KV" b3="M004E5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDISON2" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99022</SeqNum>
    <Name>L138.GravelPit-Kankakee</Name>
    <LastEdit Timestamp="2024-10-01T16:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAVLPIT" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAVLPIT" b2="138 KV" b3="GRA-KAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRAVLPIT" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAVLPIT" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANKAKEE" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99032</SeqNum>
    <Name>L230.Hosensack-NorthBoyertown.1006</Name>
    <LastEdit Timestamp="2024-12-24T13:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOSENSME" b2="230 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOSENSME" b2="230 KV" b3="HOS-NBO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBOYERTO" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBOYERTO" b2="230 KV" b3="B6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99042</SeqNum>
    <Name>L138.Belmont-Reno-Levee </Name>
    <LastEdit Timestamp="2024-10-14T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEVEE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="138 KV" b3="BEL-REN" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEVEE" b2="138 KV" b3="LEV-REN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RENO" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99052</SeqNum>
    <Name>L138.Levee-DuckCreek</Name>
    <LastEdit Timestamp="2024-11-04T11:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUCKCREE" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEVEE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUCKCREE" b2="138 KV" b3="DUC-LEV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEVEE" b2="138 KV" b3="LEVEE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEVEE" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99062</SeqNum>
    <Name>L138.DuckCreek-MillCreek</Name>
    <LastEdit Timestamp="2024-05-14T09:51:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUCKCREE" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUCKCREE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUCKCREE" b2="138 KV" b3="DUC-MIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILL AEP" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL AEP" b2="138 KV" b3="T138" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99082</SeqNum>
    <Name>L69.Chestnutburg-Gauleymt-Brownsvi-Carbond2</Name>
    <LastEdit Timestamp="2026-06-04T15:04:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARBOND2" b2="69 KV" b3="CAR-BRO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BROWNSVI" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARBOND2" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTNBG" b2="69 KV" b3="A001B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTNBG" b2="69 KV" b3="A001B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTNBG" b2="69 KV" b3="CHE-GAUL" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROWNSVI" b2="69 KV" b3="BRO-GAU1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GAULEYMT" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99083</SeqNum>
    <Name>L138.Mink-Kirk</Name>
    <LastEdit Timestamp="2024-10-02T14:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="138 KV" b3="102C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="138 KV" b3="102S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINK" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINK" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KIRK" b2="138 KV" b3="KIR-MIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99084</SeqNum>
    <Name>L138.Mink-Taylor-EastBroad</Name>
    <LastEdit Timestamp="2024-10-02T14:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBROAD" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBROAD" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINK" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINK" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MINK" b2="138 KV" b3="MIN-TAY" />
      <ContingencyEquipment Action="L" Type="LN" b1="EBROAD" b2="138 KV" b3="EBR-TAY1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TAYLOR2" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99095</SeqNum>
    <Name>138/69/34.Hancock.T1</Name>
    <LastEdit Timestamp="2024-05-14T09:49:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HANCOCK" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="HANCOCK" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="HANCOCK" b2="34 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK" b2="34 KV" b3="AK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK" b2="69 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99105</SeqNum>
    <Name>L138.64Bellwood-D460.6408</Name>
    <LastEdit Timestamp="2025-05-15T09:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="138 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="138 KV" b3="3-5" />
      <ContingencyEquipment Action="L" Type="LN" b1="64 BELLW" b2="138 KV" b3="6408" />
      <ContingencyEquipment Action="OP" Type="CB" b1="D460-6" b2="138 KV" b3="1-2" />
      <ContingencyEquipment Action="CL" Type="CB" b1="D460-6" b2="138 KV" b3="1-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99116</SeqNum>
    <Name>Haviland.WF</Name>
    <LastEdit Timestamp="2024-10-18T13:54:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HAVILAND" b2="138 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAVILAND" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HAVILAND" b2="34.5 KV" b3="NTHWSTBS" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HAVILAND" b2="34.5 KV" b3="NTHWSTSP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HAVILAND" b2="34.5 KV" b3="NTHWSTWF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99118</SeqNum>
    <Name>L345.Maywood-Herleman</Name>
    <LastEdit Timestamp="2024-10-02T14:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HERLEMAN" b2="345 KV" b3="HER-MYWD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERLEMAN" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERLEMAN" b2="345 KV" b3="V43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MYWD" b2="345 KV" b3="V43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MYWD" b2="345 KV" b3="V45" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99139</SeqNum>
    <Name>138/34.Martinsville.T7</Name>
    <LastEdit Timestamp="2025-07-10T19:04:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MARTINSV" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSV" b2="34 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSV" b2="34 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSV" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99161</SeqNum>
    <Name>DTX345.Palisades.AUX LD &amp; AUX CTG Load</Name>
    <LastEdit Timestamp="2024-10-03T15:39:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="25R8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="27R8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="29R8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="31R8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="33R8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PALISAD2" b2="345 KV" b3="AUX CTG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PALISAD2" b2="345 KV" b3="AUX_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99162</SeqNum>
    <Name>DTX345.Palisades.AUX LD2 &amp; AUX CTG2 Load</Name>
    <LastEdit Timestamp="2024-10-03T15:40:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="25F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="27F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="29F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="31F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="33F7" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PALISAD2" b2="345 KV" b3="AUX CTG2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PALISAD2" b2="345 KV" b3="AUX LD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99163</SeqNum>
    <Name>230/69.NorthLebanon.T4</Name>
    <LastEdit Timestamp="2025-06-12T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NLEBNON" b2="230 KV" b3="4BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEBNON" b2="69 KV" b3="B36" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEBNON" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NLEBNON" b2="230 KV" b3="B53" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99173</SeqNum>
    <Name>DTX138.EastLake.T399EL+ Q12 + SC.1-4 (CommonMode)</Name>
    <LastEdit Timestamp="2026-02-10T13:04:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02LARK" b2="138 KV" b3="02L-KEP1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="02LARK" b2="138 KV" b3="SW323" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02LARK" b2="138 KV" b3="SWR232" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LBRTY" b2="138 KV" b3="02L-LAM2" />
      <ContingencyEquipment Action="L" Type="LN" b1="02LBRTY" b2="138 KV" b3="02L-PR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTLAKE" b2="138 KV" b3="399EL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B54" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="EASTLAKE" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTLAKE" b2="138 KV" b3="EAS-02L1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G1SC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G2SC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G3SC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G4SC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTLAKE" b2="18 KV" b3="LOAD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTLAKE" b2="18 KV" b3="LOAD2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTLAKE" b2="18 KV" b3="LOAD3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTLAKE" b2="18 KV" b3="LOAD410" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q1T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q2T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q3T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q4T" />
      <ContingencyEquipment Action="X" Type="XF" b1="EASTLAKE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="X" Type="XF" b1="EASTLAKE" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="X" Type="XF" b1="EASTLAKE" b2="138 KV" b3="TR3" />
      <ContingencyEquipment Action="X" Type="XF" b1="EASTLAKE" b2="138 KV" b3="TR4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEITH" b2="138 KV" b3="SW264" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENYON" b2="138 KV" b3="KEN-KEI2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KENYON" b2="138 KV" b3="SW313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENYON" b2="138 KV" b3="SWR124" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEPLER" b2="138 KV" b3="KEP-KEN1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="KEPLER" b2="138 KV" b3="SW323" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEPLER" b2="138 KV" b3="SWR228" />
      <ContingencyEquipment Action="L" Type="LN" b1="LLOYD" b2="138 KV" b3="LLO-LAM2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="LAMONT" b2="138 KV" b3="SW313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMONT" b2="138 KV" b3="SWR232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLOYD" b2="138 KV" b3="Q2_T" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PROGINS" b2="138 KV" b3="LB17" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PROGINS" b2="138 KV" b3="LB18" />
      <ContingencyEquipment Action="L" Type="LN" b1="PROGINS" b2="138 KV" b3="PRO-02L1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99183</SeqNum>
    <Name>345/138.Petersburg.E</Name>
    <LastEdit Timestamp="2024-10-03T15:37:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="2C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="3C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="4C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="7C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="8C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PETERSB2" b2="138 KV" b3="AUX 4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PETERSB2" b2="34 KV" b3="E" />
      <ContingencyEquipment Action="X" Type="XF" b1="PETERSB2" b2="345 KV" b3="E-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="PETERSB2" b2="138 KV" b3="E-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="PETERSB2" b2="34 KV" b3="E-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="138 KV" b3="T11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99193</SeqNum>
    <Name>345/138.Petersburg.W</Name>
    <LastEdit Timestamp="2024-10-03T15:36:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="2A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="3A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="4A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="7A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="8A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PETERSB2" b2="138 KV" b3="AUX 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="138 KV" b3="T21" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PETERSB2" b2="34 KV" b3="W" />
      <ContingencyEquipment Action="X" Type="XF" b1="PETERSB2" b2="345 KV" b3="W-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="PETERSB2" b2="138 KV" b3="W-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="PETERSB2" b2="34 KV" b3="W-T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99243</SeqNum>
    <Name>138/35.Acca.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-08T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ACCA" b2="115 KV" b3="H174M" />
      <ContingencyEquipment Action="X" Type="XF" b1="ACCA" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99253</SeqNum>
    <Name>138/35.Acca.T2&amp;T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-09T11:11:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ACCA" b2="115 KV" b3="H274M" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ACCA" b2="115 KV" b3="H374M" />
      <ContingencyEquipment Action="X" Type="XF" b1="ACCA" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="ACCA" b2="115 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99325</SeqNum>
    <Name>115/22.Dooms.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-08T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="DOOMS4" b2="115 KV" b3="H144M" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOOMS4" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOOMS4" b2="22 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99326</SeqNum>
    <Name>115/22.Dooms.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-08T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="DOOMS4" b2="115 KV" b3="H244M" />
      <ContingencyEquipment Action="X" Type="XF" b1="DOOMS4" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOOMS4" b2="22 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99330</SeqNum>
    <Name>230/35.Fredericksburg.TX7 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-30T16:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FRDRKSBG" b2="230 KV" b3="H744M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRDRKSBG" b2="115 KV" b3="L742" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FRDRKSBG" b2="230 KV" b3="SC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRDRKSBG" b2="230 KV" b3="SC142" />
      <ContingencyEquipment Action="X" Type="XF" b1="FRDRKSBG" b2="230 KV" b3="TX7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99331</SeqNum>
    <Name>115/35.NorthBangor.TX2</Name>
    <LastEdit Timestamp="2024-11-21T14:29:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NBANGOR" b2="115 KV" b3="2BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBANGOR" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBANGOR" b2="115 KV" b3="B4" />
      <ContingencyEquipment Action="CL" Type="CB" b1="NBANGOR" b2="35 KV" b3="T-22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBANGOR" b2="35 KV" b3="T2LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99443</SeqNum>
    <Name>230/115.Harrisonburg.TX5 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-08T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARRSNBG" b2="230 KV" b3="H594M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="115 KV" b3="L592" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARRSNBG" b2="230 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99444</SeqNum>
    <Name>230/69.Harrisonburg.TX4 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-08T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARRSNBG" b2="230 KV" b3="H494M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARRSNBG" b2="69 KV" b3="HEC3" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARRSNBG" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99465</SeqNum>
    <Name>230/35.Harrisonburg.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-01T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARRSNBG" b2="115 KV" b3="H194M" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HARRSNBG" b2="115 KV" b3="SC5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRSNBG" b2="115 KV" b3="SC592" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARRSNBG" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARRSNBG" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99468</SeqNum>
    <Name>230/35.Hopewell.TX1</Name>
    <LastEdit Timestamp="2024-10-03T11:48:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="H132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="35 KV" b3="L132" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOPEWEL4" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99479</SeqNum>
    <Name>DTX138.Butler.T62 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-14T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUTL APS" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUTL APS" b2="138 KV" b3="T62 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99480</SeqNum>
    <Name>DTX138.Butler.T61 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-14T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUTL APS" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUTL APS" b2="138 KV" b3="T61 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99482</SeqNum>
    <Name>L230.NewLondon-KokomoHighlandPark</Name>
    <LastEdit Timestamp="2024-05-14T13:49:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KOKOMOPS" b2="230 KV" b3="09" />
      <ContingencyEquipment Action="L" Type="LN" b1="KOKOMOPS" b2="230 KV" b3="KOK-NEW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLONDN" b2="230 KV" b3="0936" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLONDN" b2="230 KV" b3="1609" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99489</SeqNum>
    <Name>115/13.IndustrialPark.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-09T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="INDUSTPK" b2="115 KV" b3="H244M" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDUSTPK" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INDUSTPK" b2="13 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99491</SeqNum>
    <Name>115/13.Farmville.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-09T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FARMVILL" b2="115 KV" b3="H134M" />
      <ContingencyEquipment Action="X" Type="XF" b1="FARMVILL" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FARMVILL" b2="13 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99493</SeqNum>
    <Name>230/115.Farmville.TX5</Name>
    <LastEdit Timestamp="2024-12-31T14:23:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="230 KV" b3="H532" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="115 KV" b3="L532" />
      <ContingencyEquipment Action="X" Type="XF" b1="FARMVILL" b2="230 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99496</SeqNum>
    <Name>230/35.Landstown.TX3</Name>
    <LastEdit Timestamp="2025-03-20T12:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="230 KV" b3="H352" />
      <ContingencyEquipment Action="X" Type="XF" b1="LANDSTWN" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LANDSTWN" b2="35 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99497</SeqNum>
    <Name>115/13.Locks.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-09T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOCKS" b2="115 KV" b3="H124M" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOCKS" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOCKS" b2="13 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99499</SeqNum>
    <Name>115/13.Locks.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-09T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOCKS" b2="115 KV" b3="H224M" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOCKS" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOCKS" b2="13 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99501</SeqNum>
    <Name>115/13.Northwest.TX9 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-09T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="NWEST" b2="115 KV" b3="H954M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWEST" b2="13 KV" b3="LT952" />
      <ContingencyEquipment Action="X" Type="XF" b1="NWEST" b2="115 KV" b3="TX9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99503</SeqNum>
    <Name>115/35.Oakwood.TX1</Name>
    <LastEdit Timestamp="2024-10-01T15:57:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKWOOD" b2="115 KV" b3="H162" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKWOOD" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKWOOD" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99507</SeqNum>
    <Name>115/35.Peninsula.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-27T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="PENINSLA" b2="115 KV" b3="H104M" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PENINSLA" b2="115 KV" b3="SC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENINSLA" b2="115 KV" b3="SC202" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENINSLA" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENINSLA" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99509</SeqNum>
    <Name>115/13.Plaza.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-09T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="PLAZA" b2="115 KV" b3="H124M" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLAZA" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLAZA" b2="13 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99511</SeqNum>
    <Name>230/35.ReevesAvenue.TX2</Name>
    <LastEdit Timestamp="2024-10-11T15:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="230 KV" b3="H212" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REEVESAV" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="REEVESAV" b2="230 KV" b3="TX2_" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99513</SeqNum>
    <Name>115/35.ReevesAvenue.TX3</Name>
    <LastEdit Timestamp="2025-03-20T12:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="115 KV" b3="H312" />
      <ContingencyEquipment Action="X" Type="XF" b1="REEVESAV" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REEVESAV" b2="35 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99520</SeqNum>
    <Name>230/69.Sunbury.T23</Name>
    <LastEdit Timestamp="2025-01-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SUNBURY" b2="230 KV" b3="23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="TR10TR23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="TR23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="TRAN23" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99521</SeqNum>
    <Name>L138.Faraday-Tazewell </Name>
    <LastEdit Timestamp="2024-10-23T08:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARDAY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="TAZEWELL" b2="138 KV" b3="FAR-TAZ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWELL" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWELL" b2="138 KV" b3="M2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99524</SeqNum>
    <Name>L345.BurrOak-Hiple</Name>
    <LastEdit Timestamp="2024-10-14T13:32:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURR_OAK" b2="345 KV" b3="28-29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURR_OAK" b2="345 KV" b3="29" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURR_OAK" b2="345 KV" b3="BUR-HIPL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34529" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34529-00" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99526</SeqNum>
    <Name>DTX138.BrunotIsland.BLUE</Name>
    <LastEdit Timestamp="2024-10-09T09:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNOTIS" b2="138 KV" b3="BLUE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="BUSTIE16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="BUSTIE26" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99527</SeqNum>
    <Name>DTX138.BrunotIsland.BROWN</Name>
    <LastEdit Timestamp="2024-10-10T13:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNOTIS" b2="138 KV" b3="BROWN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="BUSTIE83" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="COLLIER1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99528</SeqNum>
    <Name>DTX138.BrunotIsland.GRAY</Name>
    <LastEdit Timestamp="2024-10-11T15:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="BUSTIE15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="BUSTIE35" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNOTIS" b2="138 KV" b3="GRAY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99529</SeqNum>
    <Name>DTX138.BrunotIsland.GREEN</Name>
    <LastEdit Timestamp="2024-10-10T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="BUSTIE72" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="COLLIER0" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNOTIS" b2="138 KV" b3="GREEN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99530</SeqNum>
    <Name>DTX138.BrunotIsland.ORANGE</Name>
    <LastEdit Timestamp="2024-10-10T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="BRUNOTIS" b2="13 KV" b3="CT1A" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNOTIS" b2="138 KV" b3="GSU1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNOTIS" b2="138 KV" b3="ORANGELD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="TIE2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="TIE3-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99531</SeqNum>
    <Name>DTX138.BrunotIsland.RED</Name>
    <LastEdit Timestamp="2024-10-10T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="BUSTIE24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="MONT DUQ" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNOTIS" b2="138 KV" b3="RED" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99532</SeqNum>
    <Name>DTX138.BrunotIsland.YELLOW</Name>
    <LastEdit Timestamp="2024-10-10T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="BUSTIE39" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNOTIS" b2="138 KV" b3="NEVILTAP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNOTIS" b2="138 KV" b3="YELLOWLD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99533</SeqNum>
    <Name>DTX138.Universal.T2</Name>
    <LastEdit Timestamp="2024-10-11T16:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIVERSA" b2="138 KV" b3="BUSTIE23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIVERSA" b2="138 KV" b3="LOGAN152" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIVERSA" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99534</SeqNum>
    <Name>DTX138.Universal.T3</Name>
    <LastEdit Timestamp="2024-10-11T16:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIVERSA" b2="138 KV" b3="BUSTIE23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIVERSA" b2="138 KV" b3="BUSTIE31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIVERSA" b2="138 KV" b3="ILL57-T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIVERSA" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99535</SeqNum>
    <Name>230/69.Juniata.T3 </Name>
    <LastEdit Timestamp="2025-10-30T16:39:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="JUNIATA" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="230 KV" b3="TRAN3_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="69 KV" b3="TRAN3_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="69 KV" b3="TRAN3_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99536</SeqNum>
    <Name>230/69.Juniata.T4</Name>
    <LastEdit Timestamp="2025-12-17T19:44:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="JUNIATA" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="230 KV" b3="TRAN4_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="69 KV" b3="TRAN4_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="69 KV" b3="TRAN4_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99537</SeqNum>
    <Name>DTX138.Lyons.TR1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-05-10T10:21:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="02LYONS" b2="138 KV" b3="13462" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02LYONS" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99538</SeqNum>
    <Name>DTX138.Riverbend.TR1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-11T16:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="RVERBDOE" b2="138 KV" b3="A15" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RVERBDOE" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99539</SeqNum>
    <Name>DTX230.LewisRun.TR2</Name>
    <LastEdit Timestamp="2024-10-11T16:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEWISRN" b2="230 KV" b3="2 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISRN" b2="230 KV" b3="B61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWISRN" b2="230 KV" b3="B62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99541</SeqNum>
    <Name>DTX138.Luxor.T61 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="LUXOR" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LUXOR" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LUXOR" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LUXOR" b2="138 KV" b3="T61 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99542</SeqNum>
    <Name>138/69.GrandPoint.TR1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-02-10T12:51:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GRANDPT" b2="138 KV" b3="1TR" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GRANDPT" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDPT" b2="138 KV" b3="CAP1 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GRANDPT" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDPT" b2="138 KV" b3="CAP2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDPT" b2="69 KV" b3="CH5-7CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDPT" b2="69 KV" b3="CH8-11CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRANDPT" b2="69 KV" b3="CHAM5-7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRANDPT" b2="69 KV" b3="CHAM8-11" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRANDPT" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRANDPT" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDPT" b2="69 KV" b3="TR1CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99543</SeqNum>
    <Name>L345.PleasantPrairie-MTP.1 (WEC)</Name>
    <LastEdit Timestamp="2025-03-18T16:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MTP" b2="345 KV" b3="9114" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTP" b2="345 KV" b3="9115" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTP" b2="345 KV" b3="MTP-PLE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEAS PR" b2="345 KV" b3="10-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEAS PR" b2="345 KV" b3="9-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99544</SeqNum>
    <Name>L138.Greendale-HoosierHiddenValley</Name>
    <LastEdit Timestamp="2024-10-14T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="08HEHIDN" b2="138 KV" b3="08H-08G1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="08GRDALE" b2="138 KV" b3="138-1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="08HEHIDN" b2="138 KV" b3="SW2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99545</SeqNum>
    <Name>L138.Hubble-Weisburg-Wilmington-HEHiddenValley</Name>
    <LastEdit Timestamp="2024-10-14T13:34:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="08HEHIDN" b2="138 KV" b3="SW1" />
      <ContingencyEquipment Action="L" Type="LN" b1="08WEISBG" b2="138 KV" b3="08W-HUB1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08WEISBG" b2="138 KV" b3="LD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="08WILM_J" b2="138 KV" b3="08W-08H2" />
      <ContingencyEquipment Action="L" Type="LN" b1="08WILM_J" b2="138 KV" b3="08W-08W3" />
      <ContingencyEquipment Action="L" Type="LN" b1="08WEISBG" b2="138 KV" b3="WEI-WILM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08WIMNTN" b2="138 KV" b3="13832" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUBBLE" b2="138 KV" b3="378" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUBBLE" b2="138 KV" b3="678" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99548</SeqNum>
    <Name>L115.Pecan-Carolina.1010</Name>
    <LastEdit Timestamp="2025-05-12T13:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAROLINA" b2="115 KV" b3="101002CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CAROLINA" b2="115 KV" b3="101008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PECAN" b2="115 KV" b3="101082" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAROLINA" b2="115 KV" b3="1010A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PECAN" b2="115 KV" b3="56T1010" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99550</SeqNum>
    <Name>138/23.Clinton.T123 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-10T10:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLIN DUQ" b2="23 KV" b3="GAUCHOSP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLIN DUQ" b2="23 KV" b3="PITMG_CT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLIN DUQ" b2="23 KV" b3="T1LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLIN DUQ" b2="138 KV" b3="T1_23" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLIN DUQ" b2="138 KV" b3="T1_23DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99551</SeqNum>
    <Name>DTX138.Elwyn.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELWYN" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELWYN" b2="138 KV" b3="T2 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99552</SeqNum>
    <Name>DTX138.WoodvilleDUQ.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-15T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODVILL" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WOODVILL" b2="138 KV" b3="T3 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99553</SeqNum>
    <Name>DTX138.Legionville.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEGIONVI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LEGIONVI" b2="138 KV" b3="T1 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99554</SeqNum>
    <Name>DTX138.Legionville.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEGIONVI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LEGIONVI" b2="138 KV" b3="T2 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99555</SeqNum>
    <Name>DTX138.LogansFerry.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOGANSFE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOGANSFE" b2="138 KV" b3="T1 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99556</SeqNum>
    <Name>DTX138.Raccoon.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RACC DUQ" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RACC DUQ" b2="138 KV" b3="T1 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99557</SeqNum>
    <Name>DTX138.Raccoon.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RACC DUQ" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RACC DUQ" b2="138 KV" b3="T2 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99558</SeqNum>
    <Name>DTX138.Allenport.T1&amp;T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-14T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLENPOR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ALLENPOR" b2="138 KV" b3="T1 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLENPOR" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ALLENPOR" b2="138 KV" b3="T2 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99559</SeqNum>
    <Name>DTX138.Bethelboro.T2&amp;T62 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-14T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHELBO" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BETHELBO" b2="138 KV" b3="T2 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHELBO" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BETHELBO" b2="138 KV" b3="T62 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99560</SeqNum>
    <Name>DTX138.Buckhannon.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-04-25T16:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKHANN" b2="138 KV" b3="A605J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUCKHANN" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99561</SeqNum>
    <Name>DTX138.Burma.T71 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-14T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BURMA" b2="138 KV" b3="T71" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BURMA" b2="138 KV" b3="T71 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99562</SeqNum>
    <Name>DTX138.Burma.T72 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-16T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BURMA" b2="138 KV" b3="T72" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BURMA" b2="138 KV" b3="T72 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99563</SeqNum>
    <Name>138.Carroll.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-11-21T14:24:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CARROLL" b2="138 KV" b3="T1HDIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARROLL" b2="34.5 KV" b3="T1LCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARROLL" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99564</SeqNum>
    <Name>DTX138.Cecil.T1&amp;T61 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-14T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CECI APS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CECI APS" b2="138 KV" b3="T1 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CECI APS" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CECI APS" b2="138 KV" b3="T61 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99565</SeqNum>
    <Name>DTX138.Cecil.T62 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="CECI APS" b2="138 KV" b3="CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CECI APS" b2="138 KV" b3="CAP CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CECI APS" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CECI APS" b2="138 KV" b3="T62 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99566</SeqNum>
    <Name>DTX138.Charleroi.T62 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-14T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHARLERO" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHARLERO" b2="138 KV" b3="T62 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99567</SeqNum>
    <Name>DTX138.Charleroi.T63 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-14T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHARLERO" b2="138 KV" b3="T63" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHARLERO" b2="138 KV" b3="T63 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99568</SeqNum>
    <Name>DTX138.Connelsville.T1 &amp; T61 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-18T15:41:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CONNELSV" b2="138 KV" b3="1TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONNELSV" b2="25 KV" b3="GEN_CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CONNELSV" b2="25 KV" b3="MILLRUN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CONNELSV" b2="138 KV" b3="T1 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONNELSV" b2="25 KV" b3="T1LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONNELSV" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CONNELSV" b2="138 KV" b3="T61 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99569</SeqNum>
    <Name>DTX138.Crupperneck.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="CRUPPERN" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRUPPERN" b2="138 KV" b3="CAP1 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CRUPPERN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CRUPPERN" b2="138 KV" b3="T1 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99570</SeqNum>
    <Name>DTX138.DoubleTollGate.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-01T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOUBLETO" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DOUBLETO" b2="138 KV" b3="T3 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99571</SeqNum>
    <Name>DTX138.DoubleTollGate.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="DOUBLETO" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DOUBLETO" b2="138 KV" b3="CAP3 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOUBLETO" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DOUBLETO" b2="138 KV" b3="T4 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99572</SeqNum>
    <Name>DTX138.Edgelawn.T1 &amp; T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-14T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDGELAWN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EDGELAWN" b2="138 KV" b3="T1 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDGELAWN" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EDGELAWN" b2="138 KV" b3="T2 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99573</SeqNum>
    <Name>DTX138.Edgelawn.T3 (Sctnlz )</Name>
    <LastEdit Timestamp="2024-10-14T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDGELAWN" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EDGELAWN" b2="138 KV" b3="T3 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99574</SeqNum>
    <Name>DTX138.Everson.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EVERSON" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EVERSON" b2="138 KV" b3="T1 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99575</SeqNum>
    <Name>DTX138.Fairview.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FAIR APS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAIR APS" b2="138 KV" b3="T1 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99576</SeqNum>
    <Name>DTX138.Fawn.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FAWN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAWN" b2="138 KV" b3="T1 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99577</SeqNum>
    <Name>DTX138.FrenchCreek.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRENCHCR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FRENCHCR" b2="138 KV" b3="T1 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99578</SeqNum>
    <Name>DTX138.Gilboa.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GILB APS" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GILB APS" b2="138 KV" b3="T2 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99579</SeqNum>
    <Name>DTX138.Goffrun.T1 &amp; T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GOFFRUN" b2="138 KV" b3="A535J" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GOFFRUN" b2="138 KV" b3="A594J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOFFRUN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOFFRUN" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99580</SeqNum>
    <Name>DTX138.Gordon.T2 &amp; T62 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GORDON" b2="138 KV" b3="A2TX" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GORDON" b2="138 KV" b3="A62TX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GORDON" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GORDON" b2="138 KV" b3="T62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99581</SeqNum>
    <Name>DTX138.Washington.T2 &amp; T62 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-16T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WASH APS" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WASH APS" b2="138 KV" b3="T2 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WASH APS" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WASH APS" b2="138 KV" b3="T62 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99582</SeqNum>
    <Name>DTX138.SocialHall.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-16T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOCIALHA" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SOCIALHA" b2="138 KV" b3="T2 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99584</SeqNum>
    <Name>138/25.IronBridge.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-14T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONBRID" b2="25 KV" b3="B2TX" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="IRONBRID" b2="138 KV" b3="T2 DIS" />
      <ContingencyEquipment Action="X" Type="XF" b1="IRONBRID" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99585</SeqNum>
    <Name>DTX138.KarnsCity.T1 &amp; T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T14:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KARNSCIT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KARNSCIT" b2="138 KV" b3="T1 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KARNSCIT" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KARNSCIT" b2="138 KV" b3="T2 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99586</SeqNum>
    <Name>DTX138.KiskiValley.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KISKIVAL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KISKIVAL" b2="138 KV" b3="T1 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99587</SeqNum>
    <Name>DTX138.KiskiValley.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-16T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KISKIVAL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KISKIVAL" b2="138 KV" b3="T2 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99588</SeqNum>
    <Name>DTX138.Kittanning.T2 &amp; T62 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-16T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KITTANNI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KITTANNI" b2="138 KV" b3="T2 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KITTANNI" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KITTANNI" b2="138 KV" b3="T62 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99589</SeqNum>
    <Name>DTX138.Riverton.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="RIVERTON" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERTON" b2="138 KV" b3="CAP1 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERTON" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RIVERTON" b2="138 KV" b3="T1 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99590</SeqNum>
    <Name>DTX138.Riverton.T2 &amp; T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-01T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="RIVERTON" b2="138 KV" b3="DUM HYD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RIVERTON" b2="138 KV" b3="DUMMY DI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERTON" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RIVERTON" b2="138 KV" b3="T2 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERTON" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RIVERTON" b2="138 KV" b3="T3 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99591</SeqNum>
    <Name>DTX230.Limekiln.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-16T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LIMEKILN" b2="230 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LIMEKILN" b2="230 KV" b3="T3 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99592</SeqNum>
    <Name>DTX230.Limekiln.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-16T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LIMEKILN" b2="230 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LIMEKILN" b2="230 KV" b3="T4 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99593</SeqNum>
    <Name>DTX138.LoughsLane.T1 &amp; T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOUGHSLA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOUGHSLA" b2="138 KV" b3="T1 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOUGHSLA" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOUGHSLA" b2="138 KV" b3="T2 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99594</SeqNum>
    <Name>DTX138.LoughsLane.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOUGHSLA" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOUGHSLA" b2="138 KV" b3="T3 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99595</SeqNum>
    <Name>DTX138.Ringgold.T5 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="RINGGOLD" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RINGGOLD" b2="138 KV" b3="CAP1 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RINGGOLD" b2="138 KV" b3="T5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RINGGOLD" b2="138 KV" b3="T5 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99596</SeqNum>
    <Name>DTX138.Ringgold.T6 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RINGGOLD" b2="138 KV" b3="T6" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RINGGOLD" b2="138 KV" b3="T6 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99597</SeqNum>
    <Name>DTX138.RidgewayAPS.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="RIDG APS" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDG APS" b2="138 KV" b3="CAP1 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIDG APS" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RIDG APS" b2="138 KV" b3="T2 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99598</SeqNum>
    <Name>DTX138.Reid.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REID" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="REID" b2="138 KV" b3="T1 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99599</SeqNum>
    <Name>DTX138.Reid.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REID" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="REID" b2="138 KV" b3="T2 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99601</SeqNum>
    <Name>DTX138.Parkersburg.T1 &amp; T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-06-23T12:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PARKERSB" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PARKERSB" b2="138 KV" b3="T1 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PARKERSB" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PARKERSB" b2="138 KV" b3="T2 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99602</SeqNum>
    <Name>DTX138.PowellMountain.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="POWELLMT" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POWELLMT" b2="138 KV" b3="CAP2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POWELLMT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POWELLMT" b2="138 KV" b3="T1 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99603</SeqNum>
    <Name>DTX138.Peters.T2 &amp; T62 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-15T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PETERS" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PETERS" b2="138 KV" b3="T2 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PETERS" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PETERS" b2="138 KV" b3="T62 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99604</SeqNum>
    <Name>DTX138.Pickens.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-03-30T18:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="PICKENS" b2="138 KV" b3="A667J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PICKENS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99605</SeqNum>
    <Name>DTX138.Loyalhanna.T2 &amp; T62 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-04T13:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOYALHAN" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOYALHAN" b2="138 KV" b3="T2 DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOYALHAN" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOYALHAN" b2="138 KV" b3="T62 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99606</SeqNum>
    <Name>DTX138.Loyalhanna.T63 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-04T13:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOYALHAN" b2="138 KV" b3="T63" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOYALHAN" b2="138 KV" b3="T63 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99607</SeqNum>
    <Name>DTX138.Mccalmont.T1B &amp; T61 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-16T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCCALMON" b2="138 KV" b3="T1B" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MCCALMON" b2="138 KV" b3="T1B DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCCALMON" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MCCALMON" b2="138 KV" b3="T61 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99609</SeqNum>
    <Name>L138.Harding-Jennings-Horizon.Q11/Q2</Name>
    <LastEdit Timestamp="2025-12-24T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02GARFLD" b2="138 KV" b3="02G-GAR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02GARFLD" b2="138 KV" b3="TR71" />
      <ContingencyEquipment Action="L" Type="LN" b1="AIR_PROD" b2="138 KV" b3="AIR-JEN2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HORIZON1" b2="138 KV" b3="HOR-AIR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AIR_PROD" b2="138 KV" b3="Q2_T_232" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARFLDTP" b2="138 KV" b3="GAR-LTV1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDING2" b2="138 KV" b3="HAR-GAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDING2" b2="138 KV" b3="B650" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON1" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENNING" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="STEELYAR" b2="138 KV" b3="JEN-STE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STEELYAR" b2="138 KV" b3="LTV-STE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LTVEAST" b2="138 KV" b3="Q2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LTVEAST" b2="138 KV" b3="Q4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LTVEAST" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LTVEAST" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99610</SeqNum>
    <Name>Pecan.SP</Name>
    <LastEdit Timestamp="2026-01-09T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PECAN" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PECAN" b2="34.5 KV" b3="PECANSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PECAN" b2="115 KV" b3="PSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99611</SeqNum>
    <Name>L138.Fogwell-Mckinley</Name>
    <LastEdit Timestamp="2024-10-23T08:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FOGWELL" b2="138 KV" b3="FOG-MCK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOGWELL" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOGWELL" b2="138 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCKINLEY" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99612</SeqNum>
    <Name>L138.Foster-Maineville-Columbia</Name>
    <LastEdit Timestamp="2025-07-11T13:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLB_DEOK" b2="138 KV" b3="847" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOSTER2" b2="138 KV" b3="963" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAINEVIL" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAINEVIL" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLB_DEOK" b2="138 KV" b3="CLB-MAI" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOSTER2" b2="138 KV" b3="FOS-MAI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99613</SeqNum>
    <Name>L138.Columbia-Warren</Name>
    <LastEdit Timestamp="2024-12-17T15:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08WARREN" b2="138 KV" b3="868" />
      <ContingencyEquipment Action="L" Type="LN" b1="08WARREN" b2="138 KV" b3="08W-CLB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLB_DEOK" b2="138 KV" b3="854" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99616</SeqNum>
    <Name>L138.SouthCaldwell-Steamtown</Name>
    <LastEdit Timestamp="2024-10-16T13:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SCALDWEL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCALDWEL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCALDWEL" b2="138 KV" b3="SCA-STE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEAMTOW" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEAMTOW" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99617</SeqNum>
    <Name>12Dresden.U2</Name>
    <LastEdit Timestamp="2024-10-16T12:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT1-7 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="12 DRESD" b2="18 KV" b3="DR-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99618</SeqNum>
    <Name>12Dresden.U3</Name>
    <LastEdit Timestamp="2024-10-16T12:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="12 DRESD" b2="18 KV" b3="DR-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99619</SeqNum>
    <Name>4QuadCities.U1</Name>
    <LastEdit Timestamp="2026-02-10T09:37:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="4 QUAD C" b2="18 KV" b3="ATR11_04" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="4 QUAD C" b2="18 KV" b3="QC-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="4 QUAD C" b2="345 KV" b3="TR1 18" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99620</SeqNum>
    <Name>4 Quad Cities.U2</Name>
    <LastEdit Timestamp="2024-10-16T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT1-11CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4 QUAD C" b2="345 KV" b3="BT1011CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="4 QUAD C" b2="18 KV" b3="QC-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99621</SeqNum>
    <Name>L115.Hilltop-ReederStreet</Name>
    <LastEdit Timestamp="2024-12-17T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTOP" b2="115 KV" b3="B47" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTOP" b2="115 KV" b3="B53" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLTOP" b2="115 KV" b3="HIL-REE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REEDERST" b2="115 KV" b3="NO1 TX" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REEDERST" b2="115 KV" b3="NO2 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99622</SeqNum>
    <Name>L230.WilliamsGrove-Cumberland</Name>
    <LastEdit Timestamp="2025-12-17T16:52:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CUMB PL" b2="230 KV" b3="CUM-WIGR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="230 KV" b3="TR1_WGR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="230 KV" b3="WIGRNEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLGROV" b2="230 KV" b3="CUMB_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLGROV" b2="230 KV" b3="CUMB_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99625</SeqNum>
    <Name>L230.WestShore-WilliamsGrove</Name>
    <LastEdit Timestamp="2025-01-27T14:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="WILLGROV" b2="230 KV" b3="WIGR-WSH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLGROV" b2="230 KV" b3="WSHORE_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLGROV" b2="230 KV" b3="WSHORE_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHORE" b2="230 KV" b3="WIGR_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHORE" b2="230 KV" b3="WIGR_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99626</SeqNum>
    <Name>L138.Sandhill-ValleyGrove-BR-WLibert-Tidd</Name>
    <LastEdit Timestamp="2024-10-25T13:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BATTLERU" b2="138 KV" b3="BAT-WLI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BATTLERU" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="C_4E38F3" />
      <ContingencyEquipment Action="L" Type="LN" b1="TIDD_AEP" b2="138 KV" b3="TID-WLI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BATTLERU" b2="138 KV" b3="BAT-VAL" />
      <ContingencyEquipment Action="L" Type="LN" b1="SANDHIL2" b2="138 KV" b3="SAN-VAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VALLEYGR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WLIBERTY" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99627</SeqNum>
    <Name>L138.GeorgeWashington-BigGraveCreek-Sandhill</Name>
    <LastEdit Timestamp="2024-12-12T14:07:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BIGGRAVE" b2="138 KV" b3="BIG-GEO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIGGRAVE" b2="138 KV" b3="BIG-SAN" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BIGGRAVE" b2="138 KV" b3="W" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BIGGRAVE" b2="138 KV" b3="Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="138 KV" b3="P2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDHIL2" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99628</SeqNum>
    <Name>345/115.Wayne.1TX</Name>
    <LastEdit Timestamp="2024-10-28T14:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE" b2="345 KV" b3="B32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE" b2="345 KV" b3="B45" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE" b2="115 KV" b3="B8" />
      <ContingencyEquipment Action="X" Type="XF" b1="WAYNE" b2="345 KV" b3="NO1 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99630</SeqNum>
    <Name>L115.Trowbridge-Pantego.1020</Name>
    <LastEdit Timestamp="2024-10-22T16:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PANTEGO" b2="115 KV" b3="10201025" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANTEGO" b2="115 KV" b3="WT1020" />
      <ContingencyEquipment Action="L" Type="LN" b1="PANTEGO" b2="115 KV" b3="1020A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="115 KV" b3="167T1020" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99631</SeqNum>
    <Name>DTX115.Pantego.TX1</Name>
    <LastEdit Timestamp="2025-02-26T14:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PANTEGO" b2="115 KV" b3="103132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PANTEGO" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANTEGO" b2="115 KV" b3="WT1020" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99632</SeqNum>
    <Name>L115.Pantego-PantegoDP.1025</Name>
    <LastEdit Timestamp="2025-02-26T14:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PANTEGO" b2="115 KV" b3="PAN-PANT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PANTEGDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANTEGO" b2="115 KV" b3="10201025" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANTEGO" b2="115 KV" b3="10251031" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99633</SeqNum>
    <Name>L138.Dewey-Stanvill</Name>
    <LastEdit Timestamp="2025-11-05T06:50:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEWEY" b2="138 KV" b3="A003L2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEWEY" b2="138 KV" b3="DEW-STA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANVILL" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99634</SeqNum>
    <Name>230/69.Kearny.220-2</Name>
    <LastEdit Timestamp="2024-10-24T14:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="69 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="220-2CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEARNY" b2="230 KV" b3="220-2XF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="69 KV" b3="7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99635</SeqNum>
    <Name>230/69.Kearny.220-1</Name>
    <LastEdit Timestamp="2024-10-24T14:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="69 KV" b3="1-5" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEARNY" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="220-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="69 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99638</SeqNum>
    <Name>L138.NotreDame-SouthBend</Name>
    <LastEdit Timestamp="2024-10-18T14:00:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NOTREDAM" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="NOTREDAM" b2="138 KV" b3="NOT-SBE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NOTREDAM" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBENDAEP" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99640</SeqNum>
    <Name>L138.Catawba-Ironto-Kimballton</Name>
    <LastEdit Timestamp="2025-04-30T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CATAWBA" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="L" Type="LN" b1="CATAWBA" b2="138 KV" b3="CAT-IRON" />
      <ContingencyEquipment Action="L" Type="LN" b1="IRONTO" b2="138 KV" b3="IRO-KIMB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IRONTO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIMBALLT" b2="138 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99641</SeqNum>
    <Name>L138. Kimballton-Glenlyn</Name>
    <LastEdit Timestamp="2024-10-22T16:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENLYN" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENLYN" b2="138 KV" b3="GLE-KIM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIMBALLT" b2="138 KV" b3="K" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99646</SeqNum>
    <Name>230/69.Siegfried.T2 </Name>
    <LastEdit Timestamp="2024-10-31T08:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="HARWDTR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="TRAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="TRAN2CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SIEGFRIE" b2="230 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99647</SeqNum>
    <Name>230/69.Siegfried.T3 </Name>
    <LastEdit Timestamp="2025-08-22T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="FRACKTR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="TRAN3" />
      <ContingencyEquipment Action="X" Type="XF" b1="SIEGFRIE" b2="230 KV" b3="TRAN_3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="TRAN_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99648</SeqNum>
    <Name>L345.Edwardsport-AmoTap (CIN)</Name>
    <LastEdit Timestamp="2024-10-22T17:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOTP" b2="345 KV" b3="28-B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOTP" b2="345 KV" b3="31-28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDWARDPT" b2="345 KV" b3="34528" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDWARDPT" b2="345 KV" b3="34528-G3" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMOTP" b2="345 KV" b3="AMO-EDWA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99649</SeqNum>
    <Name>L345.Oneida-Majestic (ITC)</Name>
    <LastEdit Timestamp="2026-05-06T13:54:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAJESTIC" b2="345 KV" b3="DF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAJESTIC" b2="345 KV" b3="DM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONEIDA" b2="345 KV" b3="30F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONEIDA" b2="345 KV" b3="30H9" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAJESTIC" b2="345 KV" b3="MAJ-ONE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99654</SeqNum>
    <Name>DTX115.DupontWaynesboro.T1</Name>
    <LastEdit Timestamp="2024-09-17T12:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPWAYNE" b2="115 KV" b3="16052" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPWAYNE" b2="115 KV" b3="T122" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUPWAYNE" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99655</SeqNum>
    <Name>DTX138.Itasca.TR72</Name>
    <LastEdit Timestamp="2026-05-04T15:35:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="101 ITAS" b2="138 KV" b3="11-17" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="101 ITAS" b2="138 KV" b3="38C1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="101 ITAS" b2="138 KV" b3="38C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="5-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="C1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="L10104CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="101 ITAS" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99658</SeqNum>
    <Name>L138.SnakeHillRd-Congers.563 (NYISO)</Name>
    <LastEdit Timestamp="2024-10-22T16:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONGERS" b2="138 KV" b3="562-22-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONGERS" b2="138 KV" b3="CON-SNKE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SNKEHLRD" b2="138 KV" b3="5-24-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SNKEHLRD" b2="138 KV" b3="6-24-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99665</SeqNum>
    <Name>138/69.FremontCenter.T3</Name>
    <LastEdit Timestamp="2024-09-17T12:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONTC" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="X" Type="XF" b1="FREMONTC" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONTC" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99669</SeqNum>
    <Name>L138.133RockFall-187SchauffRoad.13304</Name>
    <LastEdit Timestamp="2024-10-24T14:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="133 ROCK" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="133 ROCK" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="133 ROCK" b2="138 KV" b3="13304_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="187 SCHA" b2="138 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="187 SCHA" b2="138 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99670</SeqNum>
    <Name>230/69.Lyons.7BK</Name>
    <LastEdit Timestamp="2024-11-05T14:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LYONS" b2="230 KV" b3="7 BK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYONS" b2="230 KV" b3="B79" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYONS" b2="230 KV" b3="B92" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYONS" b2="69 KV" b3="B94" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99671</SeqNum>
    <Name>DTX230.Wheeler.DP1</Name>
    <LastEdit Timestamp="2024-10-24T14:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEELER" b2="230 KV" b3="21612182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEELER" b2="230 KV" b3="21742182" />
      <ContingencyEquipment Action="S" Type="SD" b1="WHEELER" b2="230 KV" b3="2182Z" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHEELER" b2="230 KV" b3="DP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99672</SeqNum>
    <Name>L138.EastSpringfield-BenjaminTap-NorthTitus</Name>
    <LastEdit Timestamp="2026-02-10T13:07:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENJAMIN" b2="138 KV" b3="DATCENLD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ESPROHED" b2="138 KV" b3="A286" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESPROHED" b2="138 KV" b3="B62" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENJAMIN" b2="138 KV" b3="BEN-ESPR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTITUS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTITUS" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENJAMIN" b2="138 KV" b3="BEN-NTIT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99673</SeqNum>
    <Name>DTX138.NorthTitus.T1</Name>
    <LastEdit Timestamp="2024-10-28T12:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NTITUS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTITUS" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NTITUS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99674</SeqNum>
    <Name>230/115.Shellbank.TX6</Name>
    <LastEdit Timestamp="2024-10-23T08:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELLBNK" b2="230 KV" b3="H652" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELLBNK" b2="115 KV" b3="L652" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHELLBNK" b2="230 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99675</SeqNum>
    <Name>230/115.SkiffesCreek.TX3</Name>
    <LastEdit Timestamp="2024-11-13T12:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="230 KV" b3="H372" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="115 KV" b3="L372" />
      <ContingencyEquipment Action="X" Type="XF" b1="SKFFSCRK" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99676</SeqNum>
    <Name>500/230.SkiffesCreek.TX1</Name>
    <LastEdit Timestamp="2024-12-02T13:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="500 KV" b3="H1T582" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="230 KV" b3="L172 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SKFFSCRK" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99677</SeqNum>
    <Name>500/230.SkiffesCreek.TX2</Name>
    <LastEdit Timestamp="2024-12-02T13:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="500 KV" b3="H2T582" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="230 KV" b3="L272 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SKFFSCRK" b2="500 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99678</SeqNum>
    <Name>L230.SkiffesCreek-Kingsmill-Penniman-Waller.2154</Name>
    <LastEdit Timestamp="2024-10-28T12:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KINGSMIL" b2="230 KV" b3="2154A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGSMIL" b2="230 KV" b3="2154C" />
      <ContingencyEquipment Action="X" Type="XF" b1="KINGSMIL" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSMIL" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENNIMAN" b2="230 KV" b3="2154B1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENNIMAN" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENNIMAN" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="230 KV" b3="209T2154" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKFFSCRK" b2="230 KV" b3="215472" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALLER" b2="230 KV" b3="21132154" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99679</SeqNum>
    <Name>230/115.Carolina.TX4</Name>
    <LastEdit Timestamp="2024-10-23T08:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAROLINA" b2="230 KV" b3="H402CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAROLINA" b2="115 KV" b3="L402" />
      <ContingencyEquipment Action="X" Type="XF" b1="CAROLINA" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99681</SeqNum>
    <Name>L230.DavisDrive-SterlingPark.2194</Name>
    <LastEdit Timestamp="2025-01-24T09:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DAVISDRV" b2="230 KV" b3="2194" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISDRV" b2="230 KV" b3="H12T2194" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVISDRV" b2="230 KV" b3="H34T2194" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERLNPK" b2="230 KV" b3="20812194" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERLNPK" b2="230 KV" b3="H172" />
      <ContingencyEquipment Action="X" Type="XF" b1="STERLNPK" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STERLNPK" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99688</SeqNum>
    <Name>230/138.KokomoHighlandPark.T8</Name>
    <LastEdit Timestamp="2024-10-24T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KOKOMOPS" b2="138 KV" b3="138230-8" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KOKOMOPS" b2="230 KV" b3="230138-8" />
      <ContingencyEquipment Action="X" Type="XF" b1="KOKOMOPS" b2="230 KV" b3="T8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99689</SeqNum>
    <Name>L138.Herlan-SummerField</Name>
    <LastEdit Timestamp="2024-11-05T14:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HERLAN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERLAN" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMERFI" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="HERLAN" b2="138 KV" b3="HER-SUM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99690</SeqNum>
    <Name>L138.Herlan-SomerTap-Natrium + 138/69.Somerton.TR1</Name>
    <LastEdit Timestamp="2024-11-06T12:23:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HERLAN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERLAN" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HERLAN" b2="138 KV" b3="HER-SOM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="G1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NATRIUM2" b2="138 KV" b3="NAT-SOM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOMERTON" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SOMERTON" b2="69 KV" b3="CAPAA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOMERTON" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOMERTAP" b2="138 KV" b3="SOM-SOM1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SOMERTON" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99691</SeqNum>
    <Name>L230.Roundtable-Greenway-Enterprise.2031</Name>
    <LastEdit Timestamp="2026-03-30T18:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENTRPRIS" b2="230 KV" b3="H3T2031" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENTRPRIS" b2="230 KV" b3="H5T2031" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENTRPRIS" b2="230 KV" b3="2031B1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENWAY" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENWAY" b2="34.5 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENWAY" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENWAY" b2="34.5 KV" b3="TX4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTBL" b2="230 KV" b3="203102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTBL" b2="230 KV" b3="20312223" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENWAY" b2="230 KV" b3="2031A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99692</SeqNum>
    <Name>L345.12Dresden-939Mulberry.1227</Name>
    <LastEdit Timestamp="2025-09-03T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="12 DRESD" b2="345 KV" b3="DRE-MUL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12 DRESD" b2="345 KV" b3="L1227" />
      <ContingencyEquipment Action="OP" Type="CB" b1="939_MUL" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="939_MUL" b2="345 KV" b3="2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99693</SeqNum>
    <Name>L138.Nuttall-Quinwood</Name>
    <LastEdit Timestamp="2024-11-05T14:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NUTTALL" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NUTTALL" b2="138 KV" b3="M2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINWOOD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="NUTTALL" b2="138 KV" b3="NUT-QUI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99694</SeqNum>
    <Name>138/69.Quinwood.T2</Name>
    <LastEdit Timestamp="2024-11-05T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINWOOD" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="X" Type="XF" b1="QUINWOOD" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINWOOD" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99695</SeqNum>
    <Name>L230.DaleSummit-Shingletown</Name>
    <LastEdit Timestamp="2024-11-27T11:08:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DALESUMM" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DALESUMM" b2="230 KV" b3="DAL-SHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHINGLET" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SHINGLET" b2="230 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHINGLET" b2="230 KV" b3="DALESUMM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99696</SeqNum>
    <Name>L345.Hiple-WeedLake</Name>
    <LastEdit Timestamp="2024-11-04T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34536-37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="345 KV" b3="34537" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIPLE" b2="345 KV" b3="HIP-WEED" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEEDLAKE" b2="345 KV" b3="32H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEEDLAKE" b2="345 KV" b3="36H9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99700</SeqNum>
    <Name>138/69/46.Stanville.XT3</Name>
    <LastEdit Timestamp="2024-10-24T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="STANVILL" b2="138 KV" b3="3-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="STANVILL" b2="69 KV" b3="3-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="STANVILL" b2="46 KV" b3="3-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANVILL" b2="46 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANVILL" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANVILL" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99702</SeqNum>
    <Name>WalnutRidge.WF</Name>
    <LastEdit Timestamp="2025-12-23T07:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="980 WALN" b2="34.5 KV" b3="WALNT1CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="980 WALN" b2="34.5 KV" b3="WALNTRWF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99703</SeqNum>
    <Name>L230.BrunnerIsland-WilliamsGrove</Name>
    <LastEdit Timestamp="2026-01-07T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNNERI" b2="230 KV" b3="BRU-WIGR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="WIGR_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNNERI" b2="230 KV" b3="WIGR_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLGROV" b2="230 KV" b3="BRUNI_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLGROV" b2="230 KV" b3="BRUNI_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99705</SeqNum>
    <Name>230/69.Trenton.220-4</Name>
    <LastEdit Timestamp="2024-10-28T14:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="69 KV" b3="1-9" />
      <ContingencyEquipment Action="X" Type="XF" b1="TRENTON" b2="230 KV" b3="220-4TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="69 KV" b3="9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99706</SeqNum>
    <Name>230/69.WilliamsGrove.T1</Name>
    <LastEdit Timestamp="2024-10-28T11:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WILLGROV" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLGROV" b2="230 KV" b3="TRAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLGROV" b2="69 KV" b3="TRAN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99707</SeqNum>
    <Name>230/69.WilliamsGrove.T2</Name>
    <LastEdit Timestamp="2024-10-28T11:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WILLGROV" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLGROV" b2="230 KV" b3="TRAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLGROV" b2="69 KV" b3="TRAN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99708</SeqNum>
    <Name>L230.NorthTemple-Lyons.1031</Name>
    <LastEdit Timestamp="2025-03-05T16:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LYONS" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYONS" b2="230 KV" b3="B92" />
      <ContingencyEquipment Action="L" Type="LN" b1="LYONS" b2="230 KV" b3="LYO-NTE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTEMPLE" b2="230 KV" b3="070312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NTEMPLE" b2="230 KV" b3="103112" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99713</SeqNum>
    <Name>11Fisk.31</Name>
    <LastEdit Timestamp="2024-10-28T12:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="11 FISK" b2="12 KV" b3="FK31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="12 KV" b3="U31-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="12 KV" b3="U31-2CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99714</SeqNum>
    <Name>11Fisk.32</Name>
    <LastEdit Timestamp="2024-10-28T12:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="11 FISK" b2="12 KV" b3="FK32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="12 KV" b3="U32-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="12 KV" b3="U32-2CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99715</SeqNum>
    <Name>11Fisk.33</Name>
    <LastEdit Timestamp="2024-10-28T12:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="11 FISK" b2="12 KV" b3="FK33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="12 KV" b3="U33-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="12 KV" b3="U33-2CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99716</SeqNum>
    <Name>11Fisk.34</Name>
    <LastEdit Timestamp="2024-10-28T12:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="11 FISK" b2="12 KV" b3="FK34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="12 KV" b3="U34-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="12 KV" b3="U34-2CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99722</SeqNum>
    <Name>L345.MtVernon-E.W.Frankfurt(ILL_EQ)</Name>
    <LastEdit Timestamp="2025-11-17T11:36:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="E W FKF3" b2="345 KV" b3="30492323" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E W FKF3" b2="345 KV" b3="V7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E W FKF3" b2="345 KV" b3="V9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MT VRNO3" b2="345 KV" b3="4526" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MT VRNO3" b2="345 KV" b3="4530" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99724</SeqNum>
    <Name>OpossumCreek.SC1</Name>
    <LastEdit Timestamp="2024-12-06T10:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OPOSSUMC" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPOSSUMC" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="X" Type="XF" b1="OPOSSUMC" b2="138 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OPOSSUMC" b2="13.8 KV" b3="SC1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99726</SeqNum>
    <Name>L345.Cook-JacksonRoad</Name>
    <LastEdit Timestamp="2024-10-31T08:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COOK" b2="345 KV" b3="COO-JAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="M1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="345 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="345 KV" b3="E1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99732</SeqNum>
    <Name>138/34.48Highland.TR79+TR72</Name>
    <LastEdit Timestamp="2024-11-06T12:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="48 HIGHL" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="48 HIGHL" b2="12 KV" b3="TR72 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="48 HIGHL" b2="138 KV" b3="TR72 CS" />
      <ContingencyEquipment Action="X" Type="XF" b1="48 HIGHL" b2="138 KV" b3="TR79 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="48 HIGHL" b2="34.5 KV" b3="TR79 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="48 HIGHL" b2="138 KV" b3="TR79 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99733</SeqNum>
    <Name>L138.Broadview-Clark</Name>
    <LastEdit Timestamp="2024-11-04T11:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADVW" b2="138 KV" b3="B65" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADVW" b2="138 KV" b3="B66" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROADVW" b2="138 KV" b3="BRO-CLA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKOE" b2="138 KV" b3="B106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKOE" b2="138 KV" b3="B124" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99734</SeqNum>
    <Name>138/69.Broadview.TR1</Name>
    <LastEdit Timestamp="2024-11-04T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADVW" b2="69 KV" b3="B50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADVW" b2="138 KV" b3="B62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADVW" b2="138 KV" b3="B63" />
      <ContingencyEquipment Action="X" Type="XF" b1="BROADVW" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99735</SeqNum>
    <Name>138/69.Broadview.TR2</Name>
    <LastEdit Timestamp="2024-11-04T11:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADVW" b2="69 KV" b3="B51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADVW" b2="138 KV" b3="B66" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADVW" b2="138 KV" b3="B67" />
      <ContingencyEquipment Action="X" Type="XF" b1="BROADVW" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99738</SeqNum>
    <Name>345/26.NewarkAirport.1T</Name>
    <LastEdit Timestamp="2024-11-05T14:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NWRKARPT" b2="345 KV" b3="1-6" />
      <ContingencyEquipment Action="X" Type="XF" b1="NWRKARPT" b2="345 KV" b3="345-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWRKARPT" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NWRKARPT" b2="26 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99739</SeqNum>
    <Name>345/26.NewarkAirport.2T</Name>
    <LastEdit Timestamp="2024-11-05T14:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NWRKARPT" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWRKARPT" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="X" Type="XF" b1="NWRKARPT" b2="345 KV" b3="345-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NWRKARPT" b2="26 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99740</SeqNum>
    <Name>345/26.NewarkAirport.3T</Name>
    <LastEdit Timestamp="2024-11-05T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NWRKARPT" b2="345 KV" b3="3-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="NWRKARPT" b2="345 KV" b3="345-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWRKARPT" b2="345 KV" b3="4-5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NWRKARPT" b2="26 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99744</SeqNum>
    <Name>115/69.Brunswick.T1</Name>
    <LastEdit Timestamp="2025-06-23T12:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWCK" b2="69 KV" b3="13292" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWCK" b2="115 KV" b3="H192CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNSWCK" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99745</SeqNum>
    <Name>115/69.Brunswick.T2</Name>
    <LastEdit Timestamp="2024-11-05T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWCK" b2="69 KV" b3="5092" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWCK" b2="115 KV" b3="H292CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRUNSWCK" b2="115 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99747</SeqNum>
    <Name>JacksonsFerry.SVC</Name>
    <LastEdit Timestamp="2024-11-07T10:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="765 KV" b3="AA CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="JACKSONS" b2="765 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99748</SeqNum>
    <Name>230/69.Sunbury.T26</Name>
    <LastEdit Timestamp="2025-01-31T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SUNBURY" b2="230 KV" b3="26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="TR20TR26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="TR26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="TRAN26" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99752</SeqNum>
    <Name>L138.GrassyFalls-Quinwood</Name>
    <LastEdit Timestamp="2025-03-31T18:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRASSYFA" b2="138 KV" b3="B314" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRASSYFA" b2="138 KV" b3="GRA-QUI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINWOOD" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99754</SeqNum>
    <Name>138/69.Hunt.TR1</Name>
    <LastEdit Timestamp="2025-01-30T15:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNT3" b2="69 KV" b3="608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNT3" b2="138 KV" b3="808" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUNT3" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99757</SeqNum>
    <Name>Holloman.SP</Name>
    <LastEdit Timestamp="2026-01-09T15:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EARLEYS" b2="230 KV" b3="EARLEYCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EARLEYS" b2="35 KV" b3="HOLOMNSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="EARLEYS" b2="230 KV" b3="XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99758</SeqNum>
    <Name>L69.Swoyersville.TX1</Name>
    <LastEdit Timestamp="2024-11-13T14:46:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SWOYERSV" b2="69 KV" b3="6612" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWOYERSV" b2="69 KV" b3="6693" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWOYERSV" b2="69 KV" b3="6695" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWOYERSV" b2="13 KV" b3="LOAD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SWOYERSV" b2="69 KV" b3="XFMR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99759</SeqNum>
    <Name>L69.Swoyersville.TX2</Name>
    <LastEdit Timestamp="2024-11-08T13:15:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SWOYERSV" b2="69 KV" b3="66102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWOYERSV" b2="69 KV" b3="6612" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWOYERSV" b2="69 KV" b3="6699" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWOYERSV" b2="13 KV" b3="LOAD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SWOYERSV" b2="69 KV" b3="XFMR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99760</SeqNum>
    <Name>L115.WaughChapel-Bestgate.110540</Name>
    <LastEdit Timestamp="2024-11-14T15:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="BESTGATE" b2="13.8 KV" b3="11011102" />
      <ContingencyEquipment Action="CL" Type="CB" b1="BESTGATE" b2="13.8 KV" b3="11021103" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BESTGATE" b2="115 KV" b3="110543_1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BESTGATE" b2="115 KV" b3="110543_2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BESTGATE" b2="115 KV" b3="110543_3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BESTGATE" b2="115 KV" b3="BES-WAU0" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="540-1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUGHCHA" b2="115 KV" b3="540-2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99765</SeqNum>
    <Name>L69.Hebron-Rockawalkin-NorthSalisbury.6775</Name>
    <LastEdit Timestamp="2024-11-14T15:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRON" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEBRON" b2="69 KV" b3="HEB-ROC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSALISBU" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="L" Type="LN" b1="NSALISBU" b2="69 KV" b3="NSA-ROCK" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROCKWLKN" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROCKWLKN" b2="69 KV" b3="LS-EGRET" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99766</SeqNum>
    <Name>230/69.Sunbury.T22</Name>
    <LastEdit Timestamp="2025-03-18T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SUNBURY" b2="230 KV" b3="22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="TR22N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="TR22S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="TRAN22_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="TRAN22_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99767</SeqNum>
    <Name>Fluvanna.CC</Name>
    <LastEdit Timestamp="2024-11-18T08:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="FLUVANNA" b2="18 KV" b3="GS12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLUVANNA" b2="500 KV" b3="GS12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FLUVANNA" b2="18 KV" b3="GT12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLUVANNA" b2="500 KV" b3="GT12" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FLUVANNA" b2="18 KV" b3="GT22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLUVANNA" b2="500 KV" b3="GT22" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FLUVANNA" b2="18 KV" b3="GT32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLUVANNA" b2="500 KV" b3="GT32" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLUVANNA" b2="500 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLUVANNA" b2="500 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLUVANNA" b2="500 KV" b3="TX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLUVANNA" b2="500 KV" b3="TXS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99774</SeqNum>
    <Name>138/69.Rhodes.T1</Name>
    <LastEdit Timestamp="2025-01-27T14:58:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RHODS" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RHODS" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RHODS" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="X" Type="XF" b1="RHODS" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99775</SeqNum>
    <Name>L138.OStreet-Harrison.13826</Name>
    <LastEdit Timestamp="2025-01-27T15:16:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISN" b2="138 KV" b3="4B" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRISN" b2="138 KV" b3="HAR-OST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OST" b2="138 KV" b3="2BB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OST" b2="138 KV" b3="LOAD T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99777</SeqNum>
    <Name>L345.Covert-Palisades</Name>
    <LastEdit Timestamp="2025-12-18T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="345 KV" b3="177" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="345 KV" b3="4050" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COVERT" b2="345 KV" b3="5060" />
      <ContingencyEquipment Action="L" Type="LN" b1="COVERT" b2="345 KV" b3="COV-PALI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="33H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALISAD2" b2="345 KV" b3="33R8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99783</SeqNum>
    <Name>230/69.NorthPhiladelphia.T8</Name>
    <LastEdit Timestamp="2024-11-27T15:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="69 KV" b3="85 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="230 KV" b3="885" />
      <ContingencyEquipment Action="X" Type="XF" b1="NPHILADE" b2="230 KV" b3="NP 8TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99785</SeqNum>
    <Name>L138.Newberry-YellowCreek</Name>
    <LastEdit Timestamp="2024-12-05T16:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWBERY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWBERY" b2="138 KV" b3="NEW-YEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YELLOWCR" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99786</SeqNum>
    <Name>L138.Corey-Edlowe-KenzieCreek</Name>
    <LastEdit Timestamp="2025-08-11T12:47:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COREY" b2="138 KV" b3="COR-EDL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COREY" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COREY" b2="138 KV" b3="J2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDLOWE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDLOWE" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDLOWE" b2="138 KV" b3="EDL-KEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="138 KV" b3="M003R2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="138 KV" b3="M003R5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99787</SeqNum>
    <Name>138/69.Quinwood.T1</Name>
    <LastEdit Timestamp="2024-12-24T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINWOOD" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="X" Type="XF" b1="QUINWOOD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINWOOD" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99795</SeqNum>
    <Name>L138.KokomoHighlandPark-Delco (CIN)</Name>
    <LastEdit Timestamp="2024-11-21T14:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELCOCIN" b2="138 KV" b3="87" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KOKOMOPS" b2="138 KV" b3="87" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELCOCIN" b2="138 KV" b3="DEL-KOK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99802</SeqNum>
    <Name>L345.Oakgrove-Louisa (MEC)</Name>
    <LastEdit Timestamp="2025-03-05T16:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISA 6" b2="345 KV" b3="93924" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISA 6" b2="345 KV" b3="93934" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOUISA 6" b2="345 KV" b3="LOU-OAK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGRMEC" b2="345 KV" b3="Q10901" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKGRMEC" b2="345 KV" b3="Q10904" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99803</SeqNum>
    <Name>Louisa.U1 (MEC)</Name>
    <LastEdit Timestamp="2024-11-27T11:19:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISA 6" b2="345 KV" b3="93954" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISA 6" b2="345 KV" b3="93964" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOUISA 6" b2="345 KV" b3="TR1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LOUISA 6" b2="24 KV" b3="UIS31GUN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99804</SeqNum>
    <Name>L115.EvertsDrive-SouthTroy (Sctnlz)</Name>
    <LastEdit Timestamp="2025-06-24T08:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERTSUB" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERTSUB" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EVERTSUB" b2="115 KV" b3="EVE-STR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STROY" b2="115 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99805</SeqNum>
    <Name>L115.ETowanda-TennGas-SouthTroy (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-25T15:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B20" />
      <ContingencyEquipment Action="L" Type="LN" b1="ETOWANDA" b2="115 KV" b3="ETO-GAS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STROY" b2="115 KV" b3="A3 DS" />
      <ContingencyEquipment Action="L" Type="LN" b1="TGAS" b2="115 KV" b3="STR-GAS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TGAS" b2="115 KV" b3="TGAS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99807</SeqNum>
    <Name>L138.Peters-Crossgate (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-10T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CROSSGAT" b2="138 KV" b3="PETERS" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROSSGAT" b2="138 KV" b3="CRO-PET" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERS" b2="138 KV" b3="CROSSGAT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99808</SeqNum>
    <Name>L138.Crossgate-Cecil (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-10T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CECI APS" b2="138 KV" b3="CEC-CRO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CECI APS" b2="138 KV" b3="CROSSGAT" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CROSSGAT" b2="138 KV" b3="CECIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99845</SeqNum>
    <Name>L345.Cayuga2-Cayuga3.34535 (CIN)</Name>
    <LastEdit Timestamp="2026-05-11T15:37:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="345 KV" b3="12-35" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="345 KV" b3="34535-B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAYUGA2" b2="345 KV" b3="CAY-CAY2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CAYUGA3" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA3" b2="345 KV" b3="3502" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAYUGA3" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA3" b2="345 KV" b3="G135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA3" b2="345 KV" b3="X" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99846</SeqNum>
    <Name>L115.WindyEdge-Hazelwood-Erdman.110505</Name>
    <LastEdit Timestamp="2026-03-27T10:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ERDMAN" b2="115 KV" b3="110-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERDMAN" b2="115 KV" b3="110-2CS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="ERDMAN" b2="13 KV" b3="13BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERDMAN" b2="115 KV" b3="505_605" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERDMAN" b2="115 KV" b3="ERD-HAZ5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAZELWOO" b2="115 KV" b3="110-9HS" />
      <ContingencyEquipment Action="S" Type="SD" b1="HAZELWOO" b2="115 KV" b3="110602" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZELWOO" b2="115 KV" b3="110602CB" />
      <ContingencyEquipment Action="CL" Type="CB" b1="HAZELWOO" b2="115 KV" b3="115KVABS" />
      <ContingencyEquipment Action="CL" Type="CB" b1="HAZELWOO" b2="115 KV" b3="602_604" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAZELWOO" b2="115 KV" b3="HAZ-WIN5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110505" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99848</SeqNum>
    <Name>StatlerHill.WF</Name>
    <LastEdit Timestamp="2024-12-03T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STATHILL" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STATHILL" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="STATHILL" b2="34.5 KV" b3="FORWRDWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="STATHILL" b2="115 KV" b3="GSU1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STATHILL" b2="34.5 KV" b3="SOMERSET" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99849</SeqNum>
    <Name>L115.StatlerHill-CentralCityWest-BedfordNorth</Name>
    <LastEdit Timestamp="2024-12-03T14:16:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD" b2="115 KV" b3="B37" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CENTRALC" b2="115 KV" b3="1 TX" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEDFORD" b2="115 KV" b3="BED-CEN" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CENTRALC" b2="115 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STATHILL" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STATHILL" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTRALC" b2="115 KV" b3="CEN-STA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99851</SeqNum>
    <Name>L69.Middle-RioGrande.0607</Name>
    <LastEdit Timestamp="2024-12-24T13:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MIDD AE" b2="69 KV" b3="MID-RIO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD AE" b2="69 KV" b3="OCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIOGRAND" b2="69 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIOGRAND" b2="69 KV" b3="S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99852</SeqNum>
    <Name>L230.Cardiff-Orchard.2321</Name>
    <LastEdit Timestamp="2024-12-24T13:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARDIFF" b2="230 KV" b3="CAR-ORC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="GQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="JN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARD" b2="230 KV" b3="GCB E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARD" b2="230 KV" b3="GCB F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99853</SeqNum>
    <Name>L138.Cardiff-Lewis.1425</Name>
    <LastEdit Timestamp="2024-12-03T14:13:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="138 KV" b3="KM" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARDIFF" b2="138 KV" b3="CAR-LEW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="138 KV" b3="L OCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99854</SeqNum>
    <Name>230/138.Cardiff.T7</Name>
    <LastEdit Timestamp="2025-11-26T11:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="HP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="JN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="138 KV" b3="KM" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARDIFF" b2="230 KV" b3="T7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99856</SeqNum>
    <Name>L138.Reaver-Gay</Name>
    <LastEdit Timestamp="2024-12-18T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAY" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAY" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="L" Type="LN" b1="GAY" b2="138 KV" b3="GAY-REAV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GAY" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REAVER" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REAVER" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99857</SeqNum>
    <Name>L138.McComb-Reaver</Name>
    <LastEdit Timestamp="2025-01-24T09:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCOMB" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCCOMB" b2="138 KV" b3="MCC-REAV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REAVER" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REAVER" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99858</SeqNum>
    <Name>345/138.Desoto.T2 </Name>
    <LastEdit Timestamp="2025-01-06T15:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="345 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="L1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DESOTO" b2="345 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99859</SeqNum>
    <Name>L138.Leon-SouthBuffalo</Name>
    <LastEdit Timestamp="2024-12-30T14:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEONAP" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBUFFALO" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBUFFALO" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="SBUFFALO" b2="138 KV" b3="SBU-LEO1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99862</SeqNum>
    <Name>L138.Mitchell-Cumminsvillle-SouthFairmount.1286</Name>
    <LastEdit Timestamp="2025-01-03T14:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CUMMIVL" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CUMMIVL" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CUMMIVL" b2="138 KV" b3="08C-MIT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHCGE" b2="138 KV" b3="833" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHCGE" b2="138 KV" b3="835" />
      <ContingencyEquipment Action="L" Type="LN" b1="CUMMIVL" b2="138 KV" b3="08C-SFT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOUTHFMT" b2="138 KV" b3="976" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOUTHFMT" b2="138 KV" b3="BANK1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99863</SeqNum>
    <Name>230/69.NorthPhiladelphia.7TR </Name>
    <LastEdit Timestamp="2025-01-06T15:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="69 KV" b3="75 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPHILADE" b2="230 KV" b3="775_CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="NPHILADE" b2="230 KV" b3="NP 7TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99864</SeqNum>
    <Name>L138.Cloverdale-MtUnion + 138/69.MtUnion.T3</Name>
    <LastEdit Timestamp="2024-12-17T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVERD2" b2="138 KV" b3="CLO-MTU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="X" Type="XF" b1="MTUNION" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTUNION" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99865</SeqNum>
    <Name>L138.LindenRoad-AmblerRidge</Name>
    <LastEdit Timestamp="2025-01-10T12:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMBLERR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMBLERR" b2="138 KV" b3="AMB-LIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDENRD" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDENRD" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99867</SeqNum>
    <Name>L138.Karl-Morse</Name>
    <LastEdit Timestamp="2024-12-18T15:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KARL" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KARL" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="KARL" b2="138 KV" b3="KAR-MOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99869</SeqNum>
    <Name>L230.Metuchen-PiersonAve-MeadowRd-Brunswick.Z-2331</Name>
    <LastEdit Timestamp="2025-07-28T11:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SEC11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SECT4-12" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNSWIC" b2="230 KV" b3="BRU-MEA" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MEADOWRD" b2="230 KV" b3="DUM1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MEADOWRD" b2="230 KV" b3="DUM2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEADOWRD" b2="230 KV" b3="SILVLKSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="METUCHEN" b2="230 KV" b3="MET-PIEH" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PIERSOAV" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADOWRD" b2="230 KV" b3="MEA-PIE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERSOAV" b2="230 KV" b3="TRANT-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99872</SeqNum>
    <Name>L138.CapitalHill-Coco</Name>
    <LastEdit Timestamp="2025-01-24T08:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPITOLH" b2="138 KV" b3="V" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COCO" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COCO" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAPITOLH" b2="138 KV" b3="CAP-COC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99873</SeqNum>
    <Name>L138.GoffRun-LindenRoad </Name>
    <LastEdit Timestamp="2024-12-18T15:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOFFRUN" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GOFFRUN" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOFFRUN" b2="138 KV" b3="CAP1 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOFFRUN" b2="138 KV" b3="GOF-LIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOFFRUN" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDENRD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDENRD" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99874</SeqNum>
    <Name>L138.Hayes-WestFremont</Name>
    <LastEdit Timestamp="2025-02-28T12:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="138 KV" b3="B33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYES_FE" b2="138 KV" b3="B36" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAYES_FE" b2="138 KV" b3="HAY-WFR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B187" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WFREMONT" b2="138 KV" b3="B191" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99875</SeqNum>
    <Name>138/12.11Fisk.TR72</Name>
    <LastEdit Timestamp="2024-12-10T16:14:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="12 KV" b3="72B15CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="12 KV" b3="72B16CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="11 FISK" b2="138 KV" b3="CAP C1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="11 FISK" b2="138 KV" b3="CAP C2" />
      <ContingencyEquipment Action="X" Type="XF" b1="11 FISK" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="S" Type="SD" b1="11 FISK" b2="12 KV" b3="TR72B5Z1" />
      <ContingencyEquipment Action="S" Type="SD" b1="11 FISK" b2="12 KV" b3="TR72B6Z2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99877</SeqNum>
    <Name>L69.MountHermon-Beaglin.6757</Name>
    <LastEdit Timestamp="2025-05-06T11:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAGLIN" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAGLIN" b2="69 KV" b3="65" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTHERMON" b2="69 KV" b3="7590" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAGLIN" b2="69 KV" b3="BEA-MTH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99878</SeqNum>
    <Name>L345.MuskingumRiver-Lamping</Name>
    <LastEdit Timestamp="2025-01-31T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMPING" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMPING" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAMPING" b2="345 KV" b3="LAM-MUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="345 KV" b3="SQ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99879</SeqNum>
    <Name>345/138.Lamping.T1</Name>
    <LastEdit Timestamp="2025-01-31T15:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMPING" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMPING" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMPING" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMPING" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="X" Type="XF" b1="LAMPING" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99880</SeqNum>
    <Name>L230.Acahela-Palooka</Name>
    <LastEdit Timestamp="2024-12-30T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ACAHELA" b2="230 KV" b3="ACA-PAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ACAHELA" b2="230 KV" b3="PALON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ACAHELA" b2="230 KV" b3="PALOS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALOOKA" b2="230 KV" b3="ACAH_W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALOOKA" b2="230 KV" b3="ACA_E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99881</SeqNum>
    <Name>138/26.Linden.132-1T</Name>
    <LastEdit Timestamp="2024-12-10T16:15:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="138 KV" b3="1-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="138 KV" b3="11-12" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="138 KV" b3="132-1T" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LINDEN" b2="26 KV" b3="DUM2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99882</SeqNum>
    <Name>138/34.Madison.T1</Name>
    <LastEdit Timestamp="2025-07-10T10:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MADISON" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON" b2="34 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99883</SeqNum>
    <Name>230/69.MiddletownJct.T3</Name>
    <LastEdit Timestamp="2025-04-15T13:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MIDDLJCT" b2="230 KV" b3="3 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="230 KV" b3="B74" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="69 KV" b3="B92" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99884</SeqNum>
    <Name>L115.Chestnut-CoxDP-SouthJustice.1024</Name>
    <LastEdit Timestamp="2026-01-23T09:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTNT" b2="115 KV" b3="10011024" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTNT" b2="115 KV" b3="102482" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTNT" b2="115 KV" b3="1024A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COXDP" b2="115 KV" b3="115" />
      <ContingencyEquipment Action="S" Type="SD" b1="COXDP" b2="115 KV" b3="195A" />
      <ContingencyEquipment Action="L" Type="LN" b1="COXDP" b2="115 KV" b3="COX-SJUS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COXDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SJUSTICE" b2="115 KV" b3="10151024" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SJUSTICE" b2="115 KV" b3="102492" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99887</SeqNum>
    <Name>230/69.CedarGrove.220-2</Name>
    <LastEdit Timestamp="2025-03-26T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="69 KV" b3="1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="230 KV" b3="2-6" />
      <ContingencyEquipment Action="X" Type="XF" b1="CEDARGRO" b2="230 KV" b3="220-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="69 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99888</SeqNum>
    <Name>230/26.Trenton.220-3TR</Name>
    <LastEdit Timestamp="2024-12-10T13:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRENTON" b2="26 KV" b3="220-3LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="TRENTON" b2="230 KV" b3="220-3TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TRENTON" b2="26 KV" b3="DUM15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99889</SeqNum>
    <Name>L345.Hoytdale-McClelland</Name>
    <LastEdit Timestamp="2025-05-02T12:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="345 KV" b3="110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOYTDAL2" b2="345 KV" b3="114" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCLELND" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCLELND" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOYTDAL2" b2="345 KV" b3="HOY-MCCL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99890</SeqNum>
    <Name>L345.McClelland-Shenango</Name>
    <LastEdit Timestamp="2025-03-24T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCLELND" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCLELND" b2="345 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCCLELND" b2="345 KV" b3="MCC-SHEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="345 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHENANGO" b2="345 KV" b3="134" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99891</SeqNum>
    <Name>L345.HickoryRun-McClelland + HickoryRun.CC</Name>
    <LastEdit Timestamp="2024-12-10T16:16:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HICRUNEC" b2="345 KV" b3="1A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HICRUNEC" b2="20 KV" b3="1A CTG" />
      <ContingencyEquipment Action="X" Type="XF" b1="HICRUNEC" b2="345 KV" b3="1A GSU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HICRUNEC" b2="20 KV" b3="1AAUXLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICRUNEC" b2="345 KV" b3="1B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HICRUNEC" b2="20 KV" b3="1B CTG" />
      <ContingencyEquipment Action="X" Type="XF" b1="HICRUNEC" b2="345 KV" b3="1B GSU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HICRUNEC" b2="20 KV" b3="1BAUXLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICRUNEC" b2="345 KV" b3="1S" />
      <ContingencyEquipment Action="X" Type="XF" b1="HICRUNEC" b2="345 KV" b3="1S GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HICRUNEC" b2="22 KV" b3="1S STG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICRUNEC" b2="345 KV" b3="1Z" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCLELND" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCLELND" b2="345 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="HICRUNEC" b2="345 KV" b3="HIC-MCC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99892</SeqNum>
    <Name>L161.Shawnee-Marshall.C31(TVA)</Name>
    <LastEdit Timestamp="2025-07-28T12:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="5USEC31T" b2="161 KV" b3="812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHAL" b2="161 KV" b3="844" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARSHAL" b2="161 KV" b3="MAR-USE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEE4" b2="161 KV" b3="904" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHAWNEE4" b2="161 KV" b3="SHA-USE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99893</SeqNum>
    <Name>L69.RioGrande-Middle.0608</Name>
    <LastEdit Timestamp="2024-12-10T14:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD AE" b2="69 KV" b3="OCB N" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDD AE" b2="69 KV" b3="MID-RIO8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIOGRAND" b2="69 KV" b3="V CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIOGRAND" b2="69 KV" b3="W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99899</SeqNum>
    <Name>L69.Lynch-Chestertown.6762</Name>
    <LastEdit Timestamp="2025-11-30T18:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTERT" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTERT" b2="69 KV" b3="7280" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNCH" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTERT" b2="69 KV" b3="CHE-LYN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99902</SeqNum>
    <Name>138/34.Darrah.T1&amp;T5</Name>
    <LastEdit Timestamp="2025-08-06T14:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARRAH" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARRAH" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARRAH" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DARRAH" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DARRAH" b2="138 KV" b3="T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARRAH" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99903</SeqNum>
    <Name>L138.EastSpringfield-Broadview</Name>
    <LastEdit Timestamp="2024-12-17T16:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADVW" b2="138 KV" b3="B63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADVW" b2="138 KV" b3="B64" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROADVW" b2="138 KV" b3="BRO-ESP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESPROHED" b2="138 KV" b3="B61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99904</SeqNum>
    <Name>L138.LindenRd-Ivydale-PowellMountain </Name>
    <LastEdit Timestamp="2026-03-30T18:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="IVYDALE" b2="138 KV" b3="IVY-LIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IVYDALE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDENRD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDENRD" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POWELLMT" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="IVYDALE" b2="138 KV" b3="IVY-POW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99905</SeqNum>
    <Name>L230.NorthBoyertown-Boonetown.1006</Name>
    <LastEdit Timestamp="2024-12-24T13:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONETWN" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONETWN" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBOYERTO" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBOYERTO" b2="230 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOONETWN" b2="230 KV" b3="BOO-NBO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99918</SeqNum>
    <Name>345/138.TriState.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-13T13:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TRISTATE" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TRISTATE" b2="345 KV" b3="X1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99919</SeqNum>
    <Name>230/115.BullRun.TX6</Name>
    <LastEdit Timestamp="2024-12-18T12:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRUN" b2="230 KV" b3="H662" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRUN" b2="115 KV" b3="L662" />
      <ContingencyEquipment Action="X" Type="XF" b1="BULLRUN" b2="230 KV" b3="TX6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99922</SeqNum>
    <Name>L138.Brookside-Longview</Name>
    <LastEdit Timestamp="2024-12-24T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKSID" b2="138 KV" b3="A99" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSID" b2="138 KV" b3="B28" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKSID" b2="138 KV" b3="BRO-LON1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONGVIOE" b2="138 KV" b3="A92" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGVIOE" b2="138 KV" b3="B90" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99923</SeqNum>
    <Name>230/69.NorthBoyertown.T35</Name>
    <LastEdit Timestamp="2025-04-14T11:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NBOYERTO" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBOYERTO" b2="69 KV" b3="B44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBOYERTO" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="X" Type="XF" b1="NBOYERTO" b2="230 KV" b3="T35" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99924</SeqNum>
    <Name>L138.CherryValley-Belvidere.15624 G SPOG 2-2-B</Name>
    <LastEdit Timestamp="2024-12-31T13:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="122 BELV" b2="138 KV" b3="15624 2" />
      <ContingencyEquipment Action="S" Type="SD" b1="122 BELV" b2="138 KV" b3="15624 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="122 BELV" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="122 BELV" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="CL" Type="CB" b1="123 MARE" b2="138 KV" b3="05 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="156 CHER" b2="138 KV" b3="15624 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="156 CHER" b2="138 KV" b3="L15624CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="15624" b2="138 KV" b3="15624 3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="B465" b2="138 KV" b3="BT1-2 D" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="B465" b2="138 KV" b3="L15624CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99925</SeqNum>
    <Name>L138.Hennepin-Putnam.1771</Name>
    <LastEdit Timestamp="2024-08-16T10:42:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HENNEPIN" b2="138 KV" b3="1556" />
      <ContingencyEquipment Action="L" Type="LN" b1="HENNEPIN" b2="138 KV" b3="HEN-PUT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H23" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99926</SeqNum>
    <Name>L138.PleasantValley-Woodstck.14106 G SPOG 2-2-B</Name>
    <LastEdit Timestamp="2025-10-29T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="CB" b1="123 MARE" b2="138 KV" b3="05 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="151 WOOD" b2="138 KV" b3="14106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="141 PLEA" b2="138 KV" b3="L14106CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="151 WOOD" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="151 WOOD" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99927</SeqNum>
    <Name>230/115.Lanexa.T2</Name>
    <LastEdit Timestamp="2024-12-24T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="230 KV" b3="H232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="115 KV" b3="L232" />
      <ContingencyEquipment Action="X" Type="XF" b1="LANEXA" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99928</SeqNum>
    <Name>138/69.Henrietta.T1</Name>
    <LastEdit Timestamp="2024-12-24T13:51:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HENRIETA" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HENRIETA" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HENRIETA" b2="69 KV" b3="B28" />
      <ContingencyEquipment Action="X" Type="XF" b1="HENRIETA" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99929</SeqNum>
    <Name>DTX138.Mountain.T1&amp;T3</Name>
    <LastEdit Timestamp="2025-10-29T10:23:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MOUN ME" b2="115 KV" b3="1B12" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOUN ME" b2="115 KV" b3="2 TX 11" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MOUN ME" b2="115 KV" b3="3B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN ME" b2="115 KV" b3="98212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN ME" b2="115 KV" b3="B214" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN ME" b2="115 KV" b3="B97412" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MOUN ME" b2="115 KV" b3="CAP3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUN ME" b2="115 KV" b3="CS6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOUN ME" b2="13 KV" b3="GEN #1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOUN ME" b2="13 KV" b3="GEN #2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99931</SeqNum>
    <Name>DTX69.Rosslyn.TX1</Name>
    <LastEdit Timestamp="2024-12-31T13:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSLYN" b2="69 KV" b3="122T180" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSLYN" b2="69 KV" b3="179T180" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROSLYN" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROSLYN" b2="69 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99932</SeqNum>
    <Name>L345.Baldwin-Behv (MISO)</Name>
    <LastEdit Timestamp="2025-08-13T14:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BALDWIN3" b2="345 KV" b3="4560" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALDWIN3" b2="345 KV" b3="4564" />
      <ContingencyEquipment Action="L" Type="LN" b1="BALDWIN3" b2="345 KV" b3="BAL-BEHV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEHV" b2="345 KV" b3="V33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEHV" b2="345 KV" b3="V35" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99933</SeqNum>
    <Name>L345.Baldwin-PraireState.4538</Name>
    <LastEdit Timestamp="2025-01-03T14:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BALDWIN3" b2="345 KV" b3="4538" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALDWIN3" b2="345 KV" b3="4568" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALDWIN3" b2="345 KV" b3="4572" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRAIRST" b2="345 KV" b3="V23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRAIRST" b2="345 KV" b3="V25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99934</SeqNum>
    <Name>345/138.Turky.TR00</Name>
    <LastEdit Timestamp="2025-05-12T14:24:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TURKY H3" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURKY H3" b2="138 KV" b3="H5" />
      <ContingencyEquipment Action="X" Type="XF" b1="TURKY H3" b2="345 KV" b3="TX00" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURKY H3" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURKY H3" b2="345 KV" b3="V11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99935</SeqNum>
    <Name>L345.Bedford2-Columbus</Name>
    <LastEdit Timestamp="2024-11-19T16:23:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD2" b2="345 KV" b3="17B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD2" b2="345 KV" b3="B517" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLUMPSI" b2="345 KV" b3="COL-BED1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLUMPSI" b2="345 KV" b3="34517" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99936</SeqNum>
    <Name>L345.Belleau-Sioux</Name>
    <LastEdit Timestamp="2024-12-31T13:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELLEAU3" b2="345 KV" b3="30102317" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEAU3" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIOUX  3" b2="345 KV" b3="30H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIOUX  3" b2="345 KV" b3="32H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99937</SeqNum>
    <Name>L138.Brokaw-Cornbelt-Gibson (AMRN)</Name>
    <LastEdit Timestamp="2025-05-13T13:47:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROKAW" b2="138 KV" b3="BRO-CORN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="138 KV" b3="H23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="138 KV" b3="H25" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORNBELT" b2="138 KV" b3="COR-MOYE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CORNBELT" b2="138 KV" b3="CORN LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON 3" b2="138 KV" b3="1524" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99938</SeqNum>
    <Name>L138.Brokaw-Leroy-Weedman (AMRN)</Name>
    <LastEdit Timestamp="2025-11-25T16:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROKAW" b2="138 KV" b3="1592   6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="138 KV" b3="H13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="138 KV" b3="H15" />
      <ContingencyEquipment Action="L" Type="LN" b1="WEEDMAN3" b2="138 KV" b3="1592   5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEEDMAN3" b2="138 KV" b3="1376" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEEDMAN3" b2="138 KV" b3="1397" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99939</SeqNum>
    <Name>L345.Cayuga2-CayugaCT(CIN)</Name>
    <LastEdit Timestamp="2025-08-11T15:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="345 KV" b3="12-35" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAYUGA2" b2="345 KV" b3="CAY-CAY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGA2" b2="345 KV" b3="G2-33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGACT" b2="345 KV" b3="33-B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAYUGACT" b2="345 KV" b3="46-33" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99940</SeqNum>
    <Name>L345.Clinton-LegHorn.2 [ILL_EQ]</Name>
    <LastEdit Timestamp="2024-09-06T14:00:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON4" b2="345 KV" b3="4514" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON4" b2="345 KV" b3="BT4510" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINTON4" b2="345 KV" b3="CLI-LEG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGH" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGH" b2="345 KV" b3="V21" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99941</SeqNum>
    <Name>Edwards.U2 (MISO unit)</Name>
    <LastEdit Timestamp="2025-01-02T10:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDWARDS3" b2="69 KV" b3="UN 2CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDWARDS3" b2="69 KV" b3="UN2 EXT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDWRDSCE" b2="69 KV" b3="UN2 DYN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99942</SeqNum>
    <Name>L138.IPVA-Frederc-Flan</Name>
    <LastEdit Timestamp="2026-03-05T13:07:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FLAN" b2="138 KV" b3="FLA-FRED" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLAN" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLAN" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="L" Type="LN" b1="FREDERC3" b2="138 KV" b3="FRE-IPVA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FREDERC3" b2="138 KV" b3="XFMR LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IPVA" b2="138 KV" b3="H17" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99943</SeqNum>
    <Name>L345.Gibson-Douglas (CIN)</Name>
    <LastEdit Timestamp="2026-05-11T15:29:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUGLAS2" b2="345 KV" b3="16-52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUGLAS2" b2="345 KV" b3="53-16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON2" b2="345 KV" b3="16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON2" b2="345 KV" b3="16B11" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOUGLAS2" b2="345 KV" b3="DOU-GIBS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99944</SeqNum>
    <Name>L345.Gibson-Merom</Name>
    <LastEdit Timestamp="2025-04-08T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON2" b2="345 KV" b3="0811" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON2" b2="345 KV" b3="4511" />
      <ContingencyEquipment Action="L" Type="LN" b1="GIBSON2" b2="345 KV" b3="GIB-MER1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEROM_HE" b2="345 KV" b3="1822" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEROM_HE" b2="345 KV" b3="188" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99945</SeqNum>
    <Name>L138.Gifford-Rantoul</Name>
    <LastEdit Timestamp="2024-12-30T14:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GIFFORD" b2="138 KV" b3="GIF-RAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIFFORD" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIFFORD" b2="138 KV" b3="H11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RANTOUL3" b2="138 KV" b3="1553" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99946</SeqNum>
    <Name>L138.Gifford-Sidney</Name>
    <LastEdit Timestamp="2024-12-30T14:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GIFFORD" b2="138 KV" b3="GIF-SID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIFFORD" b2="138 KV" b3="H11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIFFORD" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIDNYCP3" b2="138 KV" b3="1651" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99947</SeqNum>
    <Name>L138.Havana-IPVA</Name>
    <LastEdit Timestamp="2024-12-31T13:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAVANA 3" b2="138 KV" b3="H7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IPVA" b2="138 KV" b3="H19" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAVANA 3" b2="138 KV" b3="HAV-IPVA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99948</SeqNum>
    <Name>L138.Cane-HavanaS-HavanaE (CIPS)</Name>
    <LastEdit Timestamp="2025-03-18T15:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CANE" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANE" b2="138 KV" b3="H7" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANE" b2="138 KV" b3="CAN-HAVA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAVA1527" b2="138 KV" b3="TR 1 LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAVANA 3" b2="138 KV" b3="30712324" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAVANA 3" b2="138 KV" b3="H3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99949</SeqNum>
    <Name>L138.Woodhall-LTVSteel-Putn</Name>
    <LastEdit Timestamp="2025-12-11T15:03:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LTVSTEEL" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LTVSTEEL" b2="138 KV" b3="LTV-WOOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H51" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H53" />
      <ContingencyEquipment Action="L" Type="LN" b1="LTVSTEEL" b2="138 KV" b3="LTV-PUT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODHALL" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODHALL" b2="138 KV" b3="H5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99950</SeqNum>
    <Name>L138.Hoopest-PaxtonEast</Name>
    <LastEdit Timestamp="2024-12-30T14:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOOPEST3" b2="138 KV" b3="1534" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAXT1600" b2="138 KV" b3="1832" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOOPEST3" b2="138 KV" b3="HOO-PAXT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99951</SeqNum>
    <Name>L138.Hoopest-Rossvill</Name>
    <LastEdit Timestamp="2025-01-03T14:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOOPEST3" b2="138 KV" b3="1533" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSSVILL" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSSVILL" b2="138 KV" b3="H5" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOOPEST3" b2="138 KV" b3="HOO-ROSS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99952</SeqNum>
    <Name>L345.Labadie-Graysum.30648308</Name>
    <LastEdit Timestamp="2024-12-31T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSUM3" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAYSUM3" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAYSUM3" b2="345 KV" b3="30648308" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LABADIE3" b2="345 KV" b3="L GRAY 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99954</SeqNum>
    <Name>L500.Marshal-Cumberland.32217(TVA)</Name>
    <LastEdit Timestamp="2024-12-31T13:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMBERL" b2="500 KV" b3="5024" />
      <ContingencyEquipment Action="L" Type="LN" b1="CUMBERL" b2="500 KV" b3="32217A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHAL" b2="500 KV" b3="5044" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHAL" b2="500 KV" b3="5074" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99955</SeqNum>
    <Name>L345.Merom-Worthington</Name>
    <LastEdit Timestamp="2024-12-31T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEROM_HE" b2="345 KV" b3="2812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEROM_HE" b2="345 KV" b3="288" />
      <ContingencyEquipment Action="L" Type="LN" b1="WORTHING" b2="345 KV" b3="WOR-MER1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORTHING" b2="345 KV" b3="280" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99956</SeqNum>
    <Name>L345.Montgomery-Spencer</Name>
    <LastEdit Timestamp="2024-12-31T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MONTGMR3" b2="345 KV" b3="MON-SPC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTGMR3" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTGMR3" b2="345 KV" b3="V15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPCK" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPCK" b2="345 KV" b3="V5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99957</SeqNum>
    <Name>L138.Morrison-Goodland(NIPSCO)</Name>
    <LastEdit Timestamp="2025-01-03T14:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="17GODLND" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="L" Type="LN" b1="17GODLND" b2="138 KV" b3="17G-MOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17GODLND" b2="69 KV" b3="69 XFR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17GODLND" b2="138 KV" b3="BUST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISON" b2="138 KV" b3="46-105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORRISON" b2="138 KV" b3="71-105" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99958</SeqNum>
    <Name>L345.MountVernon-Quot.4591</Name>
    <LastEdit Timestamp="2026-03-09T12:17:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MT VRNO3" b2="345 KV" b3="4530" />
      <ContingencyEquipment Action="L" Type="LN" b1="MT VRNO3" b2="345 KV" b3="MTV-QUOT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MT VRNO3" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUOT" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUOT" b2="345 KV" b3="V5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99959</SeqNum>
    <Name>345/138.Newton.T1(Ameren)</Name>
    <LastEdit Timestamp="2024-12-30T14:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTON 3" b2="138 KV" b3="1866" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTON 3" b2="138 KV" b3="1867" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTON 3" b2="345 KV" b3="3477" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTON 3" b2="345 KV" b3="3478" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWTON 3" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99960</SeqNum>
    <Name>L345.Newton-Tanner</Name>
    <LastEdit Timestamp="2025-11-03T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTON 3" b2="345 KV" b3="3487" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWTON 3" b2="345 KV" b3="3488" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWTON 3" b2="345 KV" b3="NEW-TANN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANN" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANN" b2="345 KV" b3="V5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99961</SeqNum>
    <Name>L345.Oreana-Latham</Name>
    <LastEdit Timestamp="2026-01-02T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LATHAM" b2="345 KV" b3="V17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LATHAM" b2="345 KV" b3="V19" />
      <ContingencyEquipment Action="L" Type="LN" b1="LATHAM" b2="345 KV" b3="LAT-ORE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OREANA" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OREANA" b2="345 KV" b3="V11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99962</SeqNum>
    <Name>L138.PaxtonEast-Gifford</Name>
    <LastEdit Timestamp="2025-01-03T14:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GIFFORD" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIFFORD" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAXT1600" b2="138 KV" b3="1833" />
      <ContingencyEquipment Action="L" Type="LN" b1="GIFFORD" b2="138 KV" b3="GIF-PAX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99963</SeqNum>
    <Name>L138.PaxtonEast-Paxton-OSWD (MISO)</Name>
    <LastEdit Timestamp="2025-08-14T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OSWD" b2="138 KV" b3="H5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSWD" b2="138 KV" b3="H7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAXT1600" b2="138 KV" b3="1834" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAXTON 3" b2="138 KV" b3="PAX-PAXT" />
      <ContingencyEquipment Action="L" Type="LN" b1="OSWD" b2="138 KV" b3="OSW-PAXT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PAXTON 3" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99965</SeqNum>
    <Name>L345.PrairieState-MountVernon</Name>
    <LastEdit Timestamp="2025-08-04T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PRAIRST" b2="345 KV" b3="32274323" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MT VRNO3" b2="345 KV" b3="4534" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MT VRNO3" b2="345 KV" b3="4538" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRAIRST" b2="345 KV" b3="V41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRAIRST" b2="345 KV" b3="V43" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99966</SeqNum>
    <Name>L345.PraireState-Jarv</Name>
    <LastEdit Timestamp="2025-01-30T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JARV" b2="345 KV" b3="V43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JARV" b2="345 KV" b3="V45" />
      <ContingencyEquipment Action="L" Type="LN" b1="JARV" b2="345 KV" b3="JAR-PRAI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRAIRST" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRAIRST" b2="345 KV" b3="V15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99967</SeqNum>
    <Name>L345.Qualitec-Whitestown</Name>
    <LastEdit Timestamp="2024-12-30T14:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="QUALITEC" b2="345 KV" b3="24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUALITEC" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITESTO" b2="345 KV" b3="03-24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITESTO" b2="345 KV" b3="24-26" />
      <ContingencyEquipment Action="L" Type="LN" b1="WHITESTO" b2="345 KV" b3="WHI-QUA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99968</SeqNum>
    <Name>L138.KewaneeEast-Boar (Ameren)</Name>
    <LastEdit Timestamp="2025-08-13T13:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOAR" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOAR" b2="138 KV" b3="H7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEWANEE" b2="138 KV" b3="1366" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOAR" b2="138 KV" b3="BOA-KEWA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99969</SeqNum>
    <Name>345/138.Sidney.TR1</Name>
    <LastEdit Timestamp="2024-12-31T13:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SIDNYCP3" b2="345 KV" b3="B019CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIDNYCP3" b2="138 KV" b3="B100" />
      <ContingencyEquipment Action="X" Type="XF" b1="SIDNYCP3" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99970</SeqNum>
    <Name>L138.Springboro-LuseRoad</Name>
    <LastEdit Timestamp="2025-01-17T10:55:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08SPNGBR" b2="138 KV" b3="13807-91" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUSE_RD" b2="138 KV" b3="7E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUSE_RD" b2="138 KV" b3="7W" />
      <ContingencyEquipment Action="L" Type="LN" b1="LUSE_RD" b2="138 KV" b3="LUS-SPNG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99971</SeqNum>
    <Name>L345.Baldwin-Turky.4521</Name>
    <LastEdit Timestamp="2024-12-31T13:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BALDWIN3" b2="345 KV" b3="4521" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALDWIN3" b2="345 KV" b3="4592" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALDWIN3" b2="345 KV" b3="4596" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURKY H3" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURKY H3" b2="345 KV" b3="V9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99972</SeqNum>
    <Name>L138.Vermilion-NChampgn</Name>
    <LastEdit Timestamp="2024-11-27T10:40:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NCHAMPGN" b2="138 KV" b3="H5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NCHAMPGN" b2="138 KV" b3="H7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VERM1333" b2="138 KV" b3="1306" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VERM1333" b2="138 KV" b3="1310" />
      <ContingencyEquipment Action="L" Type="LN" b1="NCHAMPGN" b2="138 KV" b3="NCH-VERM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99973</SeqNum>
    <Name>L138.Vermilion-Tilton2</Name>
    <LastEdit Timestamp="2024-11-27T10:41:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TILTN EC" b2="138 KV" b3="1316" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TILTN EC" b2="138 KV" b3="1320" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VERM1333" b2="138 KV" b3="1326" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VERM1333" b2="138 KV" b3="1330" />
      <ContingencyEquipment Action="L" Type="LN" b1="TILTN EC" b2="138 KV" b3="TIL-VERM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99975</SeqNum>
    <Name>WilsonBR.Unit1</Name>
    <LastEdit Timestamp="2025-01-03T14:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONBR" b2="161 KV" b3="2078" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WILSONBR" b2="161 KV" b3="UN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99982</SeqNum>
    <Name>L138.Leon-Ripley</Name>
    <LastEdit Timestamp="2025-01-06T16:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEONAP" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEONAP" b2="138 KV" b3="LEO-RIPL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIPLEY" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99983</SeqNum>
    <Name>103Lisle.138.Cap.3&amp;4</Name>
    <LastEdit Timestamp="2025-01-03T13:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="138 KV" b3="C3-4 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="103 LISL" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="103 LISL" b2="138 KV" b3="CAP4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99984</SeqNum>
    <Name>11Fisk.138.Cap.1&amp;2</Name>
    <LastEdit Timestamp="2025-01-03T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="38C2CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="11 FISK" b2="138 KV" b3="CAP C1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="11 FISK" b2="138 KV" b3="CAP C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99985</SeqNum>
    <Name>11Fisk.138.Cap.3&amp;4</Name>
    <LastEdit Timestamp="2025-01-03T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="11 FISK" b2="138 KV" b3="38C1CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="11 FISK" b2="138 KV" b3="CAP C3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="11 FISK" b2="138 KV" b3="CAP C4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99986</SeqNum>
    <Name>111ElectJN.138.Cap.38C3&amp;38C4</Name>
    <LastEdit Timestamp="2025-01-03T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="111 ELEC" b2="138 KV" b3="38C3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="111 ELEC" b2="138 KV" b3="38C4" />
      <ContingencyEquipment Action="S" Type="SD" b1="111 ELEC" b2="138 KV" b3="C3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="138 KV" b3="C3-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99987</SeqNum>
    <Name>117ProspectHeights.138.Cap.38C1&amp;38C2</Name>
    <LastEdit Timestamp="2025-01-03T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="117 PROS" b2="138 KV" b3="38C1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="117 PROS" b2="138 KV" b3="38C2" />
      <ContingencyEquipment Action="S" Type="SD" b1="117 PROS" b2="138 KV" b3="C1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="117 PROS" b2="138 KV" b3="C1-2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99988</SeqNum>
    <Name>13Crawford.138.Cap.1&amp;2</Name>
    <LastEdit Timestamp="2025-01-03T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="C1-2 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="13 CRAWF" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="13 CRAWF" b2="138 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99989</SeqNum>
    <Name>13Crawford.138.Cap.3&amp;4</Name>
    <LastEdit Timestamp="2025-01-03T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="C3-4 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="13 CRAWF" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="13 CRAWF" b2="138 KV" b3="CAP4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99990</SeqNum>
    <Name>13Crawford.138.Cap.5&amp;6</Name>
    <LastEdit Timestamp="2025-01-03T14:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="C5-6 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="13 CRAWF" b2="138 KV" b3="CAP5" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="13 CRAWF" b2="138 KV" b3="CAP6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99991</SeqNum>
    <Name>13Crawford.138.Cap.7&amp;8</Name>
    <LastEdit Timestamp="2025-01-03T14:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="C7-8 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="13 CRAWF" b2="138 KV" b3="CAP7" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="13 CRAWF" b2="138 KV" b3="CAP8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99992</SeqNum>
    <Name>135Elmhurst.138.Cap.C1CS&amp;C2CS</Name>
    <LastEdit Timestamp="2025-01-03T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="135 ELMH" b2="138 KV" b3="38C1-2CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="138 KV" b3="C1CS_CAP" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="138 KV" b3="C2CS_CAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99993</SeqNum>
    <Name>135Elmhurst.138.Cap.C3CS&amp;C4CS</Name>
    <LastEdit Timestamp="2025-01-03T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="135 ELMH" b2="138 KV" b3="38C3-4CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="138 KV" b3="C3CS_CAP" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="135 ELMH" b2="138 KV" b3="C4CS_CAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99994</SeqNum>
    <Name>138SilverLake.138.Cap.38C3&amp;38C4</Name>
    <LastEdit Timestamp="2025-01-03T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="138 SILV" b2="138 KV" b3="38C3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="138 SILV" b2="138 KV" b3="38C4" />
      <ContingencyEquipment Action="S" Type="SD" b1="138 SILV" b2="138 KV" b3="C3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="138 KV" b3="C3-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99995</SeqNum>
    <Name>230/115.ClubHouse.TX1</Name>
    <LastEdit Timestamp="2026-06-02T08:17:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLBHOUSE" b2="230 KV" b3="H152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLBHOUSE" b2="115 KV" b3="L152" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLBHOUSE" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99996</SeqNum>
    <Name>230/115.Grottoes.TX4 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-01-06T15:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GROTTOES" b2="230 KV" b3="H484M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GROTTOES" b2="115 KV" b3="L482" />
      <ContingencyEquipment Action="X" Type="XF" b1="GROTTOES" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99997</SeqNum>
    <Name>L230.FourRiver.2044 +  DTX230.FourRivers.COOP</Name>
    <LastEdit Timestamp="2025-01-03T14:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="230 KV" b3="20442067" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOURRIVR" b2="230 KV" b3="20442125" />
      <ContingencyEquipment Action="S" Type="SD" b1="FOURRIVR" b2="230 KV" b3="2044Z" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FOURRIVR" b2="230 KV" b3="COOP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>99998</SeqNum>
    <Name>138SilverLake.138.Cap.38C1&amp;38C2</Name>
    <LastEdit Timestamp="2025-01-03T13:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="138 SILV" b2="138 KV" b3="38C1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="138 SILV" b2="138 KV" b3="38C2" />
      <ContingencyEquipment Action="S" Type="SD" b1="138 SILV" b2="138 KV" b3="C1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="138 SILV" b2="138 KV" b3="C1-2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100003</SeqNum>
    <Name>L69.Morehead-Rodburn (Tie)</Name>
    <LastEdit Timestamp="2025-01-09T14:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOREHEAD" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOREHEAD" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAYWARD" b2="69 KV" b3="HAY-MOR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOREHEAD" b2="69 KV" b3="MOR-KUM1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOREHEAD" b2="69 KV" b3="MORC-MOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RODBURN" b2="69 KV" b3="PSD_BRK1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100005</SeqNum>
    <Name>L230.Belmont-Stonewater.2178</Name>
    <LastEdit Timestamp="2026-03-24T08:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLMNTDOM" b2="230 KV" b3="217812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLMNTDOM" b2="230 KV" b3="21782286" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLMNTDOM" b2="230 KV" b3="BEL-STON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STNEWATR" b2="230 KV" b3="217862-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STNEWATR" b2="230 KV" b3="217862-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100006</SeqNum>
    <Name>138/69.Ripley.T3</Name>
    <LastEdit Timestamp="2025-02-28T12:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIPLEY" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIPLEY" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIPLEY" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100012</SeqNum>
    <Name>L138.Crescent-Donaldson</Name>
    <LastEdit Timestamp="2025-01-06T16:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRESCNT" b2="138 KV" b3="08C-08D4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESCNT" b2="138 KV" b3="840" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESCNT" b2="138 KV" b3="850" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DONALDSN" b2="138 KV" b3="976" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DONALDSN" b2="138 KV" b3="986" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DONALDSN" b2="138 KV" b3="BK3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100013</SeqNum>
    <Name>L230.Jenkins-Palooka</Name>
    <LastEdit Timestamp="2025-01-06T16:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JENKINS" b2="230 KV" b3="JEN-PAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="230 KV" b3="PALO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="230 KV" b3="ST1-PALO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALOOKA" b2="230 KV" b3="JEN-SUS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALOOKA" b2="230 KV" b3="JENK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100014</SeqNum>
    <Name>230/46.Raystown.TX2</Name>
    <LastEdit Timestamp="2025-01-06T15:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RAYSTOWN" b2="46 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAYSTOWN" b2="230 KV" b3="B25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAYSTOWN" b2="230 KV" b3="B29" />
      <ContingencyEquipment Action="X" Type="XF" b1="RAYSTOWN" b2="230 KV" b3="NO2 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100017</SeqNum>
    <Name>345/138.Hyattcs.T7</Name>
    <LastEdit Timestamp="2025-01-06T15:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="AG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="138 KV" b3="AG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="N2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HYATTCS" b2="345 KV" b3="T7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100021</SeqNum>
    <Name>L69.Columbia-WBloom-EDanvill-ECTP-Danville.2</Name>
    <LastEdit Timestamp="2025-08-29T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLU PL" b2="69 KV" b3="COL-WBL2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COLU PL" b2="69 KV" b3="DAN2INSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="69 KV" b3="DANV2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLTP" b2="69 KV" b3="CLT-DAN2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DANVILPL" b2="69 KV" b3="DUM1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EDANVIPL" b2="69 KV" b3="4178" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLTP" b2="69 KV" b3="CLT-EDA2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDANVIPL" b2="69 KV" b3="EDA-WBL2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WBLOOMSB" b2="69 KV" b3="4173" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WBLOOMSB" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WBLOOMSB" b2="69 KV" b3="WBLO_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100023</SeqNum>
    <Name>138/69.Cloverdale.T18</Name>
    <LastEdit Timestamp="2025-01-09T14:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="69 KV" b3="AD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="G2" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOVERD2" b2="138 KV" b3="T18" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100028</SeqNum>
    <Name>DTX115.Hilltop.T1</Name>
    <LastEdit Timestamp="2025-01-14T15:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILLTOP" b2="115 KV" b3="1 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTOP" b2="115 KV" b3="B44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTOP" b2="115 KV" b3="B47" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100031</SeqNum>
    <Name>L69.Engleside-WestWill-Millwood.1</Name>
    <LastEdit Timestamp="2025-10-14T18:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ENGLESID" b2="69 KV" b3="ENG-WEWI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLESID" b2="69 KV" b3="FARO1INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLESID" b2="69 KV" b3="MLWD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLWDPL" b2="69 KV" b3="BUSTIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLWDPL" b2="69 KV" b3="ENGLES1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLWDPL" b2="69 KV" b3="MLW-WEWI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTWILL" b2="69 KV" b3="T1LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTWILL" b2="69 KV" b3="T2LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100032</SeqNum>
    <Name>L69.Engleside-Millwood.2</Name>
    <LastEdit Timestamp="2025-10-14T18:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLESID" b2="69 KV" b3="FARO2INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLESID" b2="69 KV" b3="MLWD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLWDPL" b2="69 KV" b3="BUSTIE2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENGLESID" b2="69 KV" b3="ENG-MLW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLWDPL" b2="69 KV" b3="ENGLES2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100033</SeqNum>
    <Name>L69.Engleside-MillerSv-WastLanc-Manor.1</Name>
    <LastEdit Timestamp="2026-03-31T15:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ENGLESID" b2="69 KV" b3="ENG-MIL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLESID" b2="69 KV" b3="MANO1INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLESID" b2="69 KV" b3="MANO_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="ENGL_1-S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MANOR" b2="69 KV" b3="RCP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="TRAN_5" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLERSV" b2="69 KV" b3="MIL-WLA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILLERSV" b2="69 KV" b3="T1LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANOR" b2="69 KV" b3="MAN-WLA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTLANC" b2="69 KV" b3="T1LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100034</SeqNum>
    <Name>L69.Engleside-MillerSv-WestLanc-Manor.2</Name>
    <LastEdit Timestamp="2025-10-15T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ENGLESID" b2="69 KV" b3="ENG-MIL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLESID" b2="69 KV" b3="MANO2INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLESID" b2="69 KV" b3="MANO_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="ENG2WHE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="ENGL_2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLERSV" b2="69 KV" b3="MIL-WLA2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILLERSV" b2="69 KV" b3="T2LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANOR" b2="69 KV" b3="MAN-WLA2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTLANC" b2="69 KV" b3="T2LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100035</SeqNum>
    <Name>230/69.Siegfried.T1</Name>
    <LastEdit Timestamp="2025-01-09T14:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="MACR1TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="230 KV" b3="TRAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="TRAN1_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="TRAN1_W" />
      <ContingencyEquipment Action="X" Type="XF" b1="SIEGFRIE" b2="230 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100036</SeqNum>
    <Name>L69.Chatfield-NewWashington-WShelby</Name>
    <LastEdit Timestamp="2025-12-18T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHATFIEL" b2="69 KV" b3="CHA-NWAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHATFIEL" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHATFIEL" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HINESVIL" b2="69 KV" b3="HINESVL" />
      <ContingencyEquipment Action="L" Type="LN" b1="HINESVIL" b2="69 KV" b3="HIN-NWAS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NWASHNTN" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHELBY" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="HINESVIL" b2="69 KV" b3="HIN-WSHE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100044</SeqNum>
    <Name>L69.Columbia-Geisinger-Point.1</Name>
    <LastEdit Timestamp="2024-12-09T14:46:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="69 KV" b3="SUNB1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLU PL" b2="69 KV" b3="COL-GEI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GEISINGR" b2="69 KV" b3="GEI-POI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GEISINGR" b2="69 KV" b3="GEISMEDC" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POINT1" b2="69 KV" b3="4098" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POINT1" b2="69 KV" b3="4156" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POINT1" b2="69 KV" b3="4215" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100046</SeqNum>
    <Name>L69.Lewis-Pville.0771</Name>
    <LastEdit Timestamp="2025-01-09T14:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LEWIS" b2="69 KV" b3="LEW-PVL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="OCB Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PVILLE" b2="69 KV" b3="GCB M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100047</SeqNum>
    <Name>L69.Lewis-Pville.0743</Name>
    <LastEdit Timestamp="2025-01-09T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LEWIS" b2="69 KV" b3="LEW-PVL3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="OCB K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PVILLE" b2="69 KV" b3="GCB N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100048</SeqNum>
    <Name>L69.SouthHampton-Medford-Tabernacle</Name>
    <LastEdit Timestamp="2025-01-09T14:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEDFORD2" b2="69 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MEDFORD2" b2="69 KV" b3="T2LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEDFORD2" b2="69 KV" b3="MED-SAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMPTON" b2="69 KV" b3="Q615" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEDFORD2" b2="69 KV" b3="MED-TAB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TABERNAC" b2="69 KV" b3="OCB A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100049</SeqNum>
    <Name>L69.Sunbury-Columbia</Name>
    <LastEdit Timestamp="2025-05-13T09:27:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLU PL" b2="69 KV" b3="COL-GEI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="69 KV" b3="SUNB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="69 KV" b3="SUNBINSP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GEISINGR" b2="69 KV" b3="GEISMEDC" />
      <ContingencyEquipment Action="L" Type="LN" b1="GEISINGR" b2="69 KV" b3="GEI-POI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="POINT1" b2="69 KV" b3="POI-SUN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POINT1" b2="69 KV" b3="T1_LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="COLU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="COLU1PEN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100050</SeqNum>
    <Name>L138.EastElkhart-Osolo</Name>
    <LastEdit Timestamp="2025-01-24T08:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="F2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EELKHART" b2="138 KV" b3="EEL-OSO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSOLO" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100053</SeqNum>
    <Name>L69.Murphysville-Sardis (Tie)</Name>
    <LastEdit Timestamp="2025-01-13T15:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MURPHYSV" b2="69 KV" b3="CBN4_624" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MURPHYSV" b2="69 KV" b3="CBN4_627" />
      <ContingencyEquipment Action="L" Type="LN" b1="MURPHYSV" b2="69 KV" b3="MUR-SARD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SARDIS2" b2="69 KV" b3="SW615" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100054</SeqNum>
    <Name>L69.Manor-Letort-WestHempfield.1</Name>
    <LastEdit Timestamp="2025-11-25T17:06:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LANCWFIL" b2="69 KV" b3="LAN-LETO" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANCWFIL" b2="69 KV" b3="LAN-WHEM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LANCWFIL" b2="69 KV" b3="LWAFLOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="LETORT" b2="69 KV" b3="LET-MANO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LETORT" b2="69 KV" b3="LETOLOAD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LETORT" b2="69 KV" b3="LETORT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LETORT" b2="69 KV" b3="TURKEYWF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="ENG2WHE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="WHEM_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="69 KV" b3="MANO_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100055</SeqNum>
    <Name>L69.StubeyRoad-PigeonRi</Name>
    <LastEdit Timestamp="2024-11-18T12:58:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PIGEONRI" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="69 KV" b3="M000Y2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="69 KV" b3="M000Y5" />
      <ContingencyEquipment Action="L" Type="LN" b1="PIGEONRI" b2="69 KV" b3="PIG-STU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100056</SeqNum>
    <Name>L69.Brackno-Sharon3-Kenton (Tie)</Name>
    <LastEdit Timestamp="2025-01-13T15:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRACKNCO" b2="69 KV" b3="BN45_634" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRACKNCO" b2="69 KV" b3="BN45_637" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRACKNCO" b2="69 KV" b3="BRA-SHAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTN_LG" b2="69 KV" b3="B091_634" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTN_LG" b2="69 KV" b3="B091_637" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHARON3" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENTN_LG" b2="69 KV" b3="SHA-KENT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100057</SeqNum>
    <Name>L69.Sturgis-CentralSturgis</Name>
    <LastEdit Timestamp="2025-01-09T14:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CENTRLST" b2="69 KV" b3="CEN-FRA" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTRLST" b2="69 KV" b3="CEN-IND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTRLST" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTRLST" b2="69 KV" b3="M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CENTRLST" b2="69 KV" b3="PRAIRE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CENTRLST" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CENTRLST" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STURGIS" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STURGIS" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STURGIS" b2="69 KV" b3="BTM" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTRLST" b2="69 KV" b3="CEN-STU" />
      <ContingencyEquipment Action="L" Type="LN" b1="STURGIS" b2="69 KV" b3="STU-HOW1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STUBYROA" b2="69 KV" b3="STU-STU1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100058</SeqNum>
    <Name>L69.Somerset-Ferguson (Tie)</Name>
    <LastEdit Timestamp="2025-11-14T11:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FRGSNSOU" b2="69 KV" b3="SW605" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMRST_EK" b2="69 KV" b3="CBS7_654" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRGSNSOU" b2="69 KV" b3="SMR-FRGS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMRST_EK" b2="69 KV" b3="SWS7_657" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100059</SeqNum>
    <Name>L69.Hodgenvl-NewHave (Tie)</Name>
    <LastEdit Timestamp="2025-01-13T17:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HODGENVL" b2="69 KV" b3="CB604" />
      <ContingencyEquipment Action="L" Type="LN" b1="HODGENVL" b2="69 KV" b3="HOD-NEW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HODGENVL" b2="69 KV" b3="SW607" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NEW_HAVE" b2="69 KV" b3="B604_605" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100060</SeqNum>
    <Name>L69.LibertyJct-PeytonsStore-CaseyCounty</Name>
    <LastEdit Timestamp="2025-01-13T15:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CASEYCO" b2="69 KV" b3="CB624" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CASEYCO" b2="69 KV" b3="SW627" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LBRTYJCT" b2="69 KV" b3="CB614" />
      <ContingencyEquipment Action="L" Type="LN" b1="LBRTYJCT" b2="69 KV" b3="LIB-LBRT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LIBERTYU" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEYTONST" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIBERTYU" b2="69 KV" b3="LIB-PEYT" />
      <ContingencyEquipment Action="L" Type="LN" b1="CASEYCO" b2="69 KV" b3="PEY-CASE" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PEYTONST" b2="69 KV" b3="SH_186" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100061</SeqNum>
    <Name>L345.KittyHawk-Rockdale</Name>
    <LastEdit Timestamp="2024-12-19T07:29:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHK" b2="345 KV" b3="6830" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHK" b2="345 KV" b3="6832" />
      <ContingencyEquipment Action="L" Type="LN" b1="KITTYHK" b2="345 KV" b3="KIT-ROCK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKDAL3" b2="345 KV" b3="1066S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKDAL3" b2="345 KV" b3="6185S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100063</SeqNum>
    <Name>L69.ClayVillage-Defoe-NewCastleShelby-OwenCo</Name>
    <LastEdit Timestamp="2024-09-20T08:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYVILL" b2="69 KV" b3="N19-604" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYVILL" b2="69 KV" b3="CLA-DEFO" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEFOE" b2="69 KV" b3="DEF-NWCS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DEFOE" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NWCST_EK" b2="69 KV" b3="LD_185" />
      <ContingencyEquipment Action="L" Type="LN" b1="NWCST_EK" b2="69 KV" b3="NWC-OWEN" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NWCST_EK" b2="69 KV" b3="SH_186" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OWEN_CO" b2="69 KV" b3="CB614" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OWEN_CO" b2="69 KV" b3="SW617" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100064</SeqNum>
    <Name>L69.Harrisburg-NewHarrisburg-Gibson.1</Name>
    <LastEdit Timestamp="2025-05-27T18:00:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON" b2="69 KV" b3="COP1CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON" b2="69 KV" b3="COPP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GIBSON" b2="69 KV" b3="GIB-NHAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRISBU" b2="69 KV" b3="HAR-NHA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISBU" b2="69 KV" b3="HUMM_1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NHARRISB" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100066</SeqNum>
    <Name>DTX115.Liberty.NOVEC</Name>
    <LastEdit Timestamp="2024-09-19T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="115 KV" b3="100212-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="115 KV" b3="100212-4" />
      <ContingencyEquipment Action="S" Type="SD" b1="LIBERTY1" b2="115 KV" b3="1002Z" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LIBERTY1" b2="115 KV" b3="NOVEC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100067</SeqNum>
    <Name>DTX115.NewRoad.LDNOVEC</Name>
    <LastEdit Timestamp="2024-09-19T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="NEWROAD" b2="115 KV" b3="113Z" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWROAD" b2="115 KV" b3="49T113" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NEWROAD" b2="115 KV" b3="49XT113" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWROAD" b2="115 KV" b3="L2T113" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWROAD" b2="115 KV" b3="LDNOVEC" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWROAD" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100068</SeqNum>
    <Name>L115.Lanexa-Toano-KingsMill.169</Name>
    <LastEdit Timestamp="2024-09-19T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KINGSMIL" b2="115 KV" b3="169A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KINGSMIL" b2="115 KV" b3="19T169" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="115 KV" b3="16932" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANEXA" b2="115 KV" b3="169B" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TOANO" b2="115 KV" b3="169T177" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100069</SeqNum>
    <Name>69/13.Delaware.T1 + Delaware.U9-12</Name>
    <LastEdit Timestamp="2025-09-05T12:07:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA PE" b2="13 KV" b3="10 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA PE" b2="13 KV" b3="11 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA PE" b2="13 KV" b3="12 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA PE" b2="13 KV" b3="9 CT CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA PE" b2="69 KV" b3="CB-03" />
      <ContingencyEquipment Action="X" Type="XF" b1="DELA PE" b2="69 KV" b3="DEL 1TR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA PE" b2="13 KV" b3="UNIT09" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA PE" b2="13 KV" b3="UNIT10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA PE" b2="13 KV" b3="UNIT11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA PE" b2="13 KV" b3="UNIT12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100070</SeqNum>
    <Name>L138.MeadowBrook-WWinchester.MRB1</Name>
    <LastEdit Timestamp="2025-08-25T11:58:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="B28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD9" />
      <ContingencyEquipment Action="L" Type="LN" b1="MEADOWBR" b2="138 KV" b3="MEA-WWI" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WWINCHES" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WWINCHES" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WWINCHES" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100073</SeqNum>
    <Name>L138.Antietam-EHagerstown</Name>
    <LastEdit Timestamp="2026-03-30T18:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ANTIETAM" b2="138 KV" b3="A1367" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANTIETAM" b2="138 KV" b3="ANT-EHA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EHAGERST" b2="138 KV" b3="ANTIETAM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100074</SeqNum>
    <Name>L138.Brookhaven-Pierpont</Name>
    <LastEdit Timestamp="2025-01-15T17:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKHAV" b2="138 KV" b3="BRO-PIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKHAV" b2="138 KV" b3="PIERPONT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERPONT" b2="138 KV" b3="BROOKHAV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100075</SeqNum>
    <Name>230/36.CannonBranch.TX4</Name>
    <LastEdit Timestamp="2025-01-16T15:50:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CANNONBR" b2="230 KV" b3="H422" />
      <ContingencyEquipment Action="X" Type="XF" b1="CANNONBR" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CANNONBR" b2="36.5 KV" b3="TX4 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100076</SeqNum>
    <Name>138/69/34.HickoryCreek.T8</Name>
    <LastEdit Timestamp="2025-01-17T15:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HICKORYC" b2="138 KV" b3="8-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="HICKORYC" b2="69 KV" b3="8-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="HICKORYC" b2="34 KV" b3="8-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORYC" b2="34 KV" b3="BH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORYC" b2="69 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORYC" b2="138 KV" b3="XT8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100086</SeqNum>
    <Name>L230.VirginiaHills-Carlyle-Potomacy-Glebe.248A</Name>
    <LastEdit Timestamp="2025-11-24T09:59:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARLYLES" b2="230 KV" b3="CAR-POT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLEBE" b2="230 KV" b3="24892" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GLEBE" b2="230 KV" b3="24899M" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLEBE" b2="230 KV" b3="GLE-POTO" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARLYLES" b2="230 KV" b3="CAR-VAHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VAHILLS" b2="230 KV" b3="DB24832" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100088</SeqNum>
    <Name>L138.Terra-FivePointsDP-Wharton.189</Name>
    <LastEdit Timestamp="2025-02-26T16:18:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="WHARTON4" b2="115 KV" b3="189A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FIVEPTDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERRA" b2="115 KV" b3="18952" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERRA" b2="115 KV" b3="189T1031" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIVEPTDP" b2="115 KV" b3="FIV-TERR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHARTON4" b2="115 KV" b3="82T189" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WHARTON4" b2="115 KV" b3="82TX189" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WHARTON4" b2="115 KV" b3="SC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHARTON4" b2="115 KV" b3="SC122" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100089</SeqNum>
    <Name>L138.Terra-Pantego.1031</Name>
    <LastEdit Timestamp="2025-01-24T09:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PANTEGO" b2="115 KV" b3="10251031" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PANTEGO" b2="115 KV" b3="103132" />
      <ContingencyEquipment Action="L" Type="LN" b1="PANTEGO" b2="115 KV" b3="PAN-TERR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERRA" b2="115 KV" b3="103152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERRA" b2="115 KV" b3="189T1031" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100090</SeqNum>
    <Name>L138.Wolfhill-SpringCreek-SouthAbingdon</Name>
    <LastEdit Timestamp="2026-03-02T17:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SABINGDN" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="L" Type="LN" b1="SABINGDN" b2="138 KV" b3="SAB-SPR" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPRINGCR" b2="138 KV" b3="SPR-WOL2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRINGCR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRINGCR" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFHILL" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100091</SeqNum>
    <Name>L138.SouthAbingdon-Abingdon</Name>
    <LastEdit Timestamp="2025-01-24T09:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ABINGDON" b2="138 KV" b3="ABI-SAB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ABINGDON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ABINGDON" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ABINGDON" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ABINGDON" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ABINGDON" b2="138 KV" b3="XT3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SABINGDN" b2="138 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100092</SeqNum>
    <Name>500/138.Nagel.T1</Name>
    <LastEdit Timestamp="2025-01-27T13:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="500 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="500 KV" b3="J1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="138 KV" b3="K1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NAGELAEP" b2="500 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100093</SeqNum>
    <Name>L138.Garver-RockiesExprerss.7581</Name>
    <LastEdit Timestamp="2025-01-21T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="138 KV" b3="882" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="138 KV" b3="884" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARVER" b2="138 KV" b3="GAR-ROCK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKIES" b2="138 KV" b3="896" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKIES" b2="138 KV" b3="898" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100094</SeqNum>
    <Name>L138.Garver-ToddHunter.5689</Name>
    <LastEdit Timestamp="2025-01-21T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="138 KV" b3="887" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="138 KV" b3="889" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARVER" b2="138 KV" b3="GAR-TODH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="925" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="927" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100095</SeqNum>
    <Name>L138.Auburn-AuburnC3 + cap</Name>
    <LastEdit Timestamp="2025-04-24T14:42:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="AUBURN" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="AUBURN" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="L" Type="LN" b1="AUBURN" b2="138 KV" b3="AUB-AUB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUBURN" b2="138 KV" b3="BB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="AUBURN" b2="138 KV" b3="CAPB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUBURN" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUBURN" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUBURN" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUBURN" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUBURN" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUBURN" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AUBURNC3" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100096</SeqNum>
    <Name>DTX138.Oakley.BK1</Name>
    <LastEdit Timestamp="2025-01-31T15:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="138 KV" b3="805" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08OAKLEY" b2="138 KV" b3="815" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08OAKLEY" b2="138 KV" b3="BK1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100097</SeqNum>
    <Name>L230.Trenton-HuntersGlen.N2345</Name>
    <LastEdit Timestamp="2025-08-01T13:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTGLEN" b2="230 KV" b3="1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTGLEN" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="1-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="11-12" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTGLEN" b2="230 KV" b3="HUN-TREN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100098</SeqNum>
    <Name>L345.McLean-PontiacMidpoint.8001</Name>
    <LastEdit Timestamp="2026-01-02T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="80 PONTI" b2="345 KV" b3="8001" />
      <ContingencyEquipment Action="OP" Type="CB" b1="80 PONTI" b2="345 KV" b3="BT3-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="80 PONTI" b2="345 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="92 MCLEA" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="92 MCLEA" b2="345 KV" b3="1-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100100</SeqNum>
    <Name>L138.Kewanee-SchauffRd-Normandy.7405</Name>
    <LastEdit Timestamp="2024-05-15T11:23:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="125 NORM" b2="138 KV" b3="7405 3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="125 NORM" b2="138 KV" b3="TR77 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="187 SCHA" b2="138 KV" b3="1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="187 SCHA" b2="138 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="187 SCHA" b2="138 KV" b3="7405 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="74 KEWAN" b2="138 KV" b3="7405 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="74 KEWAN" b2="138 KV" b3="L7405" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100101</SeqNum>
    <Name>L138.PotterSS-PennChemical.Z-192</Name>
    <LastEdit Timestamp="2025-01-24T09:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENNCHEM" b2="138 KV" b3="Z192" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENNCHEM" b2="138 KV" b3="PEN-POT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE10-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100102</SeqNum>
    <Name>L138.PotterSS-PennChemical.Z-92</Name>
    <LastEdit Timestamp="2025-01-24T09:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENNCHEM" b2="138 KV" b3="Z92" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENNCHEM" b2="138 KV" b3="PEN-POT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE4-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100103</SeqNum>
    <Name>L138.JKSmith-Hunt3</Name>
    <LastEdit Timestamp="2025-02-21T12:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNT3" b2="138 KV" b3="814" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNT3" b2="138 KV" b3="HUN-JKS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB834" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB91T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100104</SeqNum>
    <Name>L138.Dale-Hunt3</Name>
    <LastEdit Timestamp="2025-02-24T11:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DALESTN" b2="138 KV" b3="CB_834" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNT3" b2="138 KV" b3="824" />
      <ContingencyEquipment Action="L" Type="LN" b1="DALESTN" b2="138 KV" b3="DAL-HUNT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100106</SeqNum>
    <Name>L115.BoydtonPlankRd-Herbert.1026</Name>
    <LastEdit Timestamp="2025-01-21T13:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOYTNPRD" b2="115 KV" b3="102652" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOYTNPRD" b2="115 KV" b3="H2T1026" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERBERT2" b2="115 KV" b3="102602" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOYTNPRD" b2="115 KV" b3="BOY-HERB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERBERT2" b2="115 KV" b3="H2T1026" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100107</SeqNum>
    <Name>115/69.VioletHill.6Bank + L115.VioletHill-QueenSt</Name>
    <LastEdit Timestamp="2025-01-21T12:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VIOLET H" b2="115 KV" b3="4 BANK" />
      <ContingencyEquipment Action="X" Type="XF" b1="VIOLET H" b2="115 KV" b3="6-BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIOLET H" b2="69 KV" b3="6B32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIOLET H" b2="115 KV" b3="98332" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIOLET H" b2="115 KV" b3="98832" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTROSE" b2="115 KV" b3="MTR-VIO" />
      <ContingencyEquipment Action="L" Type="LN" b1="QUEEN ST" b2="115 KV" b3="QUE-VIO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100108</SeqNum>
    <Name>L230.ColonialTrail-Surry.212</Name>
    <LastEdit Timestamp="2024-11-13T09:25:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLTRAIL" b2="230 KV" b3="21292" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLTRAIL" b2="230 KV" b3="YT212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="21202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="212T226" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLTRAIL" b2="230 KV" b3="COL-SURR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100109</SeqNum>
    <Name>ColonialTrail.ColtrwSP</Name>
    <LastEdit Timestamp="2025-05-05T12:31:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLTRAIL" b2="230 KV" b3="21292" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COLTRAIL" b2="34.5 KV" b3="COLTRWSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLTRAIL" b2="230 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLTRAIL" b2="230 KV" b3="X92" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100110</SeqNum>
    <Name>138/34.Osolo.T2 + T4</Name>
    <LastEdit Timestamp="2025-01-31T15:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COUNTYRD" b2="138 KV" b3="COU-OSO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSOLO" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSOLO" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OSOLO" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="OSOLO" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSOLO" b2="138 KV" b3="XT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100114</SeqNum>
    <Name>500/230.Chickahominy.TX1</Name>
    <LastEdit Timestamp="2026-06-09T06:53:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="500 KV" b3="55722" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="500 KV" b3="56722" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="L122" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHICKHOM" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100116</SeqNum>
    <Name>L69.Loomis-Lincoln</Name>
    <LastEdit Timestamp="2025-08-22T15:38:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINC UGI" b2="69 KV" b3="6615" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINC UGI" b2="13 KV" b3="LOAD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINC UGI" b2="69 KV" b3="XFMR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOOMIS" b2="69 KV" b3="66160" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINC UGI" b2="69 KV" b3="LIN-LOOM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100123</SeqNum>
    <Name>138/69.Warren.T3</Name>
    <LastEdit Timestamp="2025-07-24T16:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08WARREN" b2="138 KV" b3="868" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08WARREN" b2="138 KV" b3="870" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08WARREN" b2="138 KV" b3="BK3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100124</SeqNum>
    <Name>L230.Pioneer-Liberty.2187</Name>
    <LastEdit Timestamp="2026-02-11T13:12:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="230 KV" b3="20802187" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="230 KV" b3="218712" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LIBERTY1" b2="230 KV" b3="SC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="230 KV" b3="SC112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIONEER1" b2="230 KV" b3="21872220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIONEER1" b2="230 KV" b3="218792" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIBERTY1" b2="230 KV" b3="LIB-PION" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100125</SeqNum>
    <Name>L138.Tidd-Broadacre-EastAmsterdam </Name>
    <LastEdit Timestamp="2025-07-31T12:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROADACR" b2="138 KV" b3="BRO-EAM1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROADACR" b2="138 KV" b3="BRO-TID1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BROADACR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAMSTERD" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="L2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100126</SeqNum>
    <Name>138/69.EastAmsterdam.T1</Name>
    <LastEdit Timestamp="2025-01-29T14:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EAMSTERD" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAMSTERD" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAMSTERD" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100127</SeqNum>
    <Name>230/69.WestShore.TRAN1</Name>
    <LastEdit Timestamp="2025-01-30T15:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WSHORE" b2="230 KV" b3="TRAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHORE" b2="230 KV" b3="TRAN1HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHORE" b2="69 KV" b3="TRAN1LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100128</SeqNum>
    <Name>500/230.Nagel.T5</Name>
    <LastEdit Timestamp="2025-01-31T15:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NAGELAEP" b2="500 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="500 KV" b3="H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="500 KV" b3="J2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAGELAEP" b2="230 KV" b3="S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100129</SeqNum>
    <Name>L138.Harrison-Zuber</Name>
    <LastEdit Timestamp="2025-01-31T15:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISCS" b2="138 KV" b3="2C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISCS" b2="138 KV" b3="2W" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRISCS" b2="138 KV" b3="HAR-ZUB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZUBER" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZUBER" b2="138 KV" b3="G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100130</SeqNum>
    <Name>L138.FieldsCreek-Hernshaw</Name>
    <LastEdit Timestamp="2025-01-28T18:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDCRE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDCRE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIELDCRE" b2="138 KV" b3="FIE-HERN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERNSHAW" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100131</SeqNum>
    <Name>L138.ChesterfieldAve-BullittStreet</Name>
    <LastEdit Timestamp="2025-01-31T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLITST" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BULLITST" b2="138 KV" b3="BUL-CHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER2" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100132</SeqNum>
    <Name>Chestnut.SP</Name>
    <LastEdit Timestamp="2025-01-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTNT" b2="115 KV" b3="52-T1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESTNT" b2="34.5 KV" b3="CHESTSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTNT" b2="115 KV" b3="T-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100133</SeqNum>
    <Name>L138.133RockFall-187SchauffRoad.18702</Name>
    <LastEdit Timestamp="2025-01-27T14:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="133 ROCK" b2="138 KV" b3="BT1-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="133 ROCK" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="187 SCHA" b2="138 KV" b3="8-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="187 SCHA" b2="138 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="133 ROCK" b2="138 KV" b3="ROC-SCHA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100134</SeqNum>
    <Name>L230.Copperstone-Hummelstown.1097</Name>
    <LastEdit Timestamp="2025-02-21T14:53:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="230 KV" b3="HUMM-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="230 KV" b3="HUMM-S" />
      <ContingencyEquipment Action="L" Type="LN" b1="COPPERST" b2="230 KV" b3="COP-HUM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="230 KV" b3="COPPE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="230 KV" b3="COPPW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100135</SeqNum>
    <Name>138/26.Linden.132-2</Name>
    <LastEdit Timestamp="2025-01-27T13:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINDEN" b2="138 KV" b3="132-2CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LINDEN" b2="138 KV" b3="132-2T" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LINDEN" b2="26 KV" b3="DUM7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100137</SeqNum>
    <Name>345/69.Bayonne.T3</Name>
    <LastEdit Timestamp="2024-09-19T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="69 KV" b3="1-5" />
      <ContingencyEquipment Action="X" Type="XF" b1="BAYONNE" b2="345 KV" b3="345-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="345 KV" b3="345-3CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="69 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100138</SeqNum>
    <Name>230/20.Keystone.T5 + U3</Name>
    <LastEdit Timestamp="2025-05-22T12:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="20 KV" b3="3TX_11_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="230 KV" b3="B204" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEYSTONE" b2="20 KV" b3="SS #3" />
      <ContingencyEquipment Action="X" Type="XF" b1="KEYSTONE" b2="230 KV" b3="TR5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KEYSTONE" b2="20 KV" b3="UNIT 3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100139</SeqNum>
    <Name>L115.PossumPoint-BethelDP-Smoketown.18A</Name>
    <LastEdit Timestamp="2025-07-24T16:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SMOKTNDP" b2="115 KV" b3="18A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHELDP" b2="115 KV" b3="BET-POSS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHELDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POSSUMP4" b2="115 KV" b3="1892" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POSSUMP4" b2="115 KV" b3="1898" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMOKTNDP" b2="115 KV" b3="18T145" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100140</SeqNum>
    <Name>NorthernNeck.U1&amp;2&amp;3&amp;4 + SVC</Name>
    <LastEdit Timestamp="2026-03-30T18:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="NRTHNECK" b2="115 KV" b3="BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NRTHNECK" b2="115 KV" b3="BUCK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NRTHNECK" b2="13 KV" b3="GT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NRTHNECK" b2="13 KV" b3="GT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NRTHNECK" b2="13 KV" b3="GT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NRTHNECK" b2="13 KV" b3="GT4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="115 KV" b3="GT52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="115 KV" b3="L4TGT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NRTHNECK" b2="115 KV" b3="SV1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NRTHNECK" b2="115 KV" b3="TX2A" />
      <ContingencyEquipment Action="X" Type="XF" b1="NRTHNECK" b2="115 KV" b3="TX2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100142</SeqNum>
    <Name>138/69.JacksonRoad.TR6</Name>
    <LastEdit Timestamp="2025-01-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="138 KV" b3="M2" />
      <ContingencyEquipment Action="X" Type="XF" b1="JACKSONR" b2="138 KV" b3="TR6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="69 KV" b3="XB6L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100143</SeqNum>
    <Name>L69.JacksonRoad-Quinn-Vintage</Name>
    <LastEdit Timestamp="2025-01-24T09:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSONR" b2="69 KV" b3="JAC-QUIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONR" b2="69 KV" b3="XB6L" />
      <ContingencyEquipment Action="L" Type="LN" b1="QUINNAEP" b2="69 KV" b3="QUI-VINT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="QUINNAEP" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINTAGE" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VINTAGE" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100144</SeqNum>
    <Name>L69.Vintage-MarshNip.Tie(AEP-NIPS)</Name>
    <LastEdit Timestamp="2025-01-27T14:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHNIP" b2="69 KV" b3="110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINTAGE" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARSHNIP" b2="69 KV" b3="MAR-VINT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100145</SeqNum>
    <Name>L69.Plymouth-Pregis-Center-MarshNip(NIPS)</Name>
    <LastEdit Timestamp="2026-06-08T10:06:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="17PLYMTH" b2="69 KV" b3="6921" />
      <ContingencyEquipment Action="L" Type="LN" b1="17PLYMTH" b2="69 KV" b3="PLY-PREG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CENTERNI" b2="69 KV" b3="CENTER1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CENTERNI" b2="69 KV" b3="CENTER2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHNIP" b2="69 KV" b3="110" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTERNI" b2="69 KV" b3="CEN-MARS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARSHNIP" b2="69 KV" b3="MARSHALL" />
      <ContingencyEquipment Action="S" Type="SD" b1="PREGIS_1" b2="69 KV" b3="6921_B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTERNI" b2="69 KV" b3="CEN-PREG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PREGIS_1" b2="69 KV" b3="HOOSRTR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PREGIS_1" b2="69 KV" b3="PIDCO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PREGIS_1" b2="69 KV" b3="PIDCO2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PREGIS_1" b2="69 KV" b3="PREGIS_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100146</SeqNum>
    <Name>138/69.Plymouth.A1(NIPS)</Name>
    <LastEdit Timestamp="2026-05-08T11:40:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="17PLYMTH" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17PLYMTH" b2="138 KV" b3="X119" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17PLYMTH" b2="138 KV" b3="X196" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17PLYMTH" b2="69 KV" b3="XFR1BKR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100147</SeqNum>
    <Name>138/69.Plymouth.B2(NIPS)</Name>
    <LastEdit Timestamp="2026-05-08T11:40:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="17PLYMTH" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17PLYMTH" b2="138 KV" b3="X221" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17PLYMTH" b2="138 KV" b3="X296" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17PLYMTH" b2="69 KV" b3="XFR2BKR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100148</SeqNum>
    <Name>L138.BurrOak-Plymouth(NIPS)</Name>
    <LastEdit Timestamp="2025-01-27T15:15:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="17PLYMTH" b2="138 KV" b3="1921" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURR_OAK" b2="138 KV" b3="BUR-17P1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17PLYMTH" b2="138 KV" b3="X119" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURR_OAK" b2="138 KV" b3="19-XFR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURR_OAK" b2="138 KV" b3="1982" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100149</SeqNum>
    <Name>L138.Plymouth-KosciuTp-NrthWest-Leesburg(NIPS)</Name>
    <LastEdit Timestamp="2025-01-24T09:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="17PLYMTH" b2="138 KV" b3="17P-KOS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17PLYMTH" b2="138 KV" b3="1921" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17PLYMTH" b2="138 KV" b3="X221" />
      <ContingencyEquipment Action="X" Type="XF" b1="KOSCIUTP" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KOSCIUTP" b2="138 KV" b3="38TI" />
      <ContingencyEquipment Action="L" Type="LN" b1="KOSCIUTP" b2="138 KV" b3="KOS-KOS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KOSCIUTP" b2="69 KV" b3="XFR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KOSPLYTP" b2="138 KV" b3="KOS-NRT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESBURG" b2="138 KV" b3="2144" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESBURG" b2="138 KV" b3="X221" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEESBURG" b2="138 KV" b3="LEE-NRT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NRTHWEST" b2="138 KV" b3="NORTHWST" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100150</SeqNum>
    <Name>L138.Stillwell-Plymouth(NIPS)</Name>
    <LastEdit Timestamp="2025-01-24T09:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="17PLYMTH" b2="138 KV" b3="X196" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17PLYMTH" b2="138 KV" b3="X296" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STILLWEL" b2="138 KV" b3="96" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STILLWEL" b2="138 KV" b3="9697" />
      <ContingencyEquipment Action="L" Type="LN" b1="STILLWEL" b2="138 KV" b3="STI-17P1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100154</SeqNum>
    <Name>138/69.ClinchField.1-T</Name>
    <LastEdit Timestamp="2025-01-24T08:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CLINCHFI" b2="138 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHFI" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHFI" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100157</SeqNum>
    <Name>L230.CopperStone-Dauphin+230/69.Dauphin.T1</Name>
    <LastEdit Timestamp="2024-11-27T17:17:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COPPERST" b2="230 KV" b3="COP-DAU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="230 KV" b3="DAUP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="230 KV" b3="DAUPMIJU" />
      <ContingencyEquipment Action="X" Type="XF" b1="DAUPHIN" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAUPHIN" b2="230 KV" b3="JUNICOP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAUPHIN" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100158</SeqNum>
    <Name>L230.Devilsbrook-Trenton.D2335</Name>
    <LastEdit Timestamp="2025-08-11T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEVILSBR" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEVILSBR" b2="230 KV" b3="DEV-TREN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEVILSBR" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="1-13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="13-14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100159</SeqNum>
    <Name>Spotsylvania.SP</Name>
    <LastEdit Timestamp="2025-04-23T16:31:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="SPOTSLV" b2="500 KV" b3="515A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="500 KV" b3="515T573" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="500 KV" b3="515T594" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SPOTSLV" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SPOTSLV" b2="34.5 KV" b3="CAP2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SPOTSLV" b2="34.5 KV" b3="CAP3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SPOTSLV" b2="34.5 KV" b3="CAP4" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SPOTSLV" b2="34.5 KV" b3="CAP5" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SPOTSLV" b2="34.5 KV" b3="CAP6" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SPOTSLV" b2="34.5 KV" b3="CAP7" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SPOTSLV" b2="34.5 KV" b3="CAP8" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPOTSLV" b2="34.5 KV" b3="SPOTS1SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPOTSLV" b2="34.5 KV" b3="SPOTS2SP" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPOTSLV" b2="500 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPOTSLV" b2="500 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100162</SeqNum>
    <Name>345/138.Garver.T24</Name>
    <LastEdit Timestamp="2025-01-27T13:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="345 KV" b3="1431" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="345 KV" b3="1442" />
      <ContingencyEquipment Action="X" Type="XF" b1="GARVER" b2="345 KV" b3="24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="138 KV" b3="878" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="138 KV" b3="881" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100164</SeqNum>
    <Name>L138.187SchauffRd-977GreenRvr.97720 + GreenRvr.WF</Name>
    <LastEdit Timestamp="2025-01-27T15:02:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="187 SCHA" b2="138 KV" b3="7-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="187 SCHA" b2="138 KV" b3="8-9" />
      <ContingencyEquipment Action="L" Type="LN" b1="187 SCHA" b2="138 KV" b3="97720" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="977 GREE" b2="34.5 KV" b3="CAP11" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="977 GREE" b2="34.5 KV" b3="CAP12" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="977 GREE" b2="34.5 KV" b3="CAP21" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="977 GREE" b2="34.5 KV" b3="CAP22" />
      <ContingencyEquipment Action="U" Type="GEN" b1="977 GREE" b2="34.5 KV" b3="GRVRU1WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="977 GREE" b2="34.5 KV" b3="GRVRU2WF" />
      <ContingencyEquipment Action="X" Type="XF" b1="977 GREE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="977 GREE" b2="138 KV" b3="T1 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="977 GREE" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="977 GREE" b2="138 KV" b3="T2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100165</SeqNum>
    <Name>230/69.NewMilford.220-1</Name>
    <LastEdit Timestamp="2025-04-14T11:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWMILFR" b2="69 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWMILFR" b2="69 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWMILFR" b2="230 KV" b3="220-1CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWMILFR" b2="230 KV" b3="220-1XFR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100166</SeqNum>
    <Name>230.Brambleton.Capacitor.SC1</Name>
    <LastEdit Timestamp="2025-01-27T13:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="BRAMBLET" b2="230 KV" b3="SC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="SC102" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100168</SeqNum>
    <Name>138/69.Ebenezer.BK7</Name>
    <LastEdit Timestamp="2025-01-27T13:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08EBNZR5" b2="138 KV" b3="951" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EBNZR5" b2="138 KV" b3="955" />
      <ContingencyEquipment Action="X" Type="XF" b1="08EBNZR5" b2="138 KV" b3="BK7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EBNZR5" b2="69 KV" b3="CB671" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100169</SeqNum>
    <Name>161/69.SummerShade.XF1810(EKPC)</Name>
    <LastEdit Timestamp="2025-01-27T13:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMSHADE" b2="161 KV" b3="1058" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMSHADE" b2="69 KV" b3="CB658" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUMSHADE" b2="161 KV" b3="XF1810" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100170</SeqNum>
    <Name>L69.Columbia-Danville-GTI-Cheroke.1</Name>
    <LastEdit Timestamp="2026-01-12T12:06:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHEROKE1" b2="69 KV" b3="4047" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHEROKE1" b2="69 KV" b3="CHER1_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLTP" b2="69 KV" b3="CLT-DAN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLTP" b2="69 KV" b3="CLT-EDA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLTP" b2="69 KV" b3="CLTP_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLU PL" b2="69 KV" b3="COL-WBL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="69 KV" b3="DANV1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COLU PL" b2="69 KV" b3="DANVINSP" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHEROKE1" b2="69 KV" b3="CHE-DAN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DANVILPL" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EDANVIPL" b2="69 KV" b3="4178" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDANVIPL" b2="69 KV" b3="EDAN2_LD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GTI" b2="69 KV" b3="4223" />
      <ContingencyEquipment Action="L" Type="LN" b1="DANVILPL" b2="69 KV" b3="DAN-GTI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GTI" b2="69 KV" b3="GTI_LD1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POINT1" b2="69 KV" b3="4215" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHEROKE1" b2="69 KV" b3="CHE-POI1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WBLOOMSB" b2="69 KV" b3="4173" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDANVIPL" b2="69 KV" b3="EDA-WBL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100171</SeqNum>
    <Name>L138.Garver-Union-Carlisle</Name>
    <LastEdit Timestamp="2025-01-29T15:22:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="08CRLISL" b2="138 KV" b3="08C-08U1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08CRLISL" b2="138 KV" b3="952" />
      <ContingencyEquipment Action="L" Type="LN" b1="08UNION" b2="138 KV" b3="08U-GARV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08UNION" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="138 KV" b3="876" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="138 KV" b3="878" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100172</SeqNum>
    <Name>ColonialTrail.SpringSP</Name>
    <LastEdit Timestamp="2026-05-11T11:37:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="COLTRAIL" b2="230 KV" b3="SPR GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COLTRAIL" b2="34.5 KV" b3="SPRNG1SP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLTRAIL" b2="230 KV" b3="X92" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLTRAIL" b2="230 KV" b3="XT2197" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100178</SeqNum>
    <Name>L345.Jarv-Stallin</Name>
    <LastEdit Timestamp="2025-01-30T15:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JARV" b2="345 KV" b3="JAR-STAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JARV" b2="345 KV" b3="V31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JARV" b2="345 KV" b3="V33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STALLIN3" b2="345 KV" b3="4518" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STALLIN3" b2="345 KV" b3="4581" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100179</SeqNum>
    <Name>L69.Massey-Kennedyville-Lynch.6799</Name>
    <LastEdit Timestamp="2025-02-21T14:55:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KENNEDYV" b2="69 KV" b3="KND-MAS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KENNEDYV" b2="69 KV" b3="KNDYVL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNCH" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENNEDYV" b2="69 KV" b3="KND-LYN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASSEY" b2="69 KV" b3="60 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASSEY" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MASSEY" b2="69 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100180</SeqNum>
    <Name>L69.Church-Clough-Chestertown.6773</Name>
    <LastEdit Timestamp="2025-01-31T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTERT" b2="69 KV" b3="7310" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTERT" b2="69 KV" b3="7390" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTERT" b2="69 KV" b3="CHE-CLOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="7240" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="7260" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCH" b2="69 KV" b3="CHU-CLOU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOUGH" b2="69 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100181</SeqNum>
    <Name>L69.Sunbury-Columb2.LD</Name>
    <LastEdit Timestamp="2025-05-13T09:29:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="COLU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="COLU2MID" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100184</SeqNum>
    <Name>230/26.Trenton.220-2TR</Name>
    <LastEdit Timestamp="2025-01-31T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="1-9" />
      <ContingencyEquipment Action="X" Type="XF" b1="TRENTON" b2="230 KV" b3="220-2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="26 KV" b3="BUSTIEIM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRENTON" b2="26 KV" b3="LOAD IM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100185</SeqNum>
    <Name>L69.Wyemills-Stevensville</Name>
    <LastEdit Timestamp="2025-01-31T15:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STVNSVIL" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="7530" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="7540" />
      <ContingencyEquipment Action="L" Type="LN" b1="STVNSVIL" b2="69 KV" b3="STV-WYE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100189</SeqNum>
    <Name>L138.Lamping-Rouse-BellRidge</Name>
    <LastEdit Timestamp="2025-08-04T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMPING" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMPING" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAMPING" b2="138 KV" b3="LAM-ROU" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLRIDG" b2="138 KV" b3="BEL-ROUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100190</SeqNum>
    <Name>L115.Blairsville-Shelocta.1002</Name>
    <LastEdit Timestamp="2025-02-07T11:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAIRSVE" b2="115 KV" b3="B37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAIRSVE" b2="115 KV" b3="B45" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLAIRSVE" b2="115 KV" b3="BLA-SHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELOCTA" b2="115 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100191</SeqNum>
    <Name>138/69.Hartford.T4</Name>
    <LastEdit Timestamp="2025-01-31T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARTFORD" b2="69 KV" b3="M" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARTFORD" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARTFORD" b2="138 KV" b3="XT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100192</SeqNum>
    <Name>L138.Arroyo-WylieRidge.218 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-01-31T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARROYO" b2="138 KV" b3="ARR-WYL" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ARROYO" b2="138 KV" b3="WYLIERID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="W5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="W6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100193</SeqNum>
    <Name>L138.Airco-Arroyo (Sctnlz)</Name>
    <LastEdit Timestamp="2025-01-31T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AIRCO" b2="138 KV" b3="ARROYOCB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AIRCO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AIRCO" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="AIRCO" b2="138 KV" b3="AIR-ARR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ARROYO" b2="138 KV" b3="AIRCO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100194</SeqNum>
    <Name>L138.Arroyo-WylieRidge.212 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-08T15:04:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARROYO" b2="138 KV" b3="ARR-ART" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARRJCT" b2="138 KV" b3="ART-SCH" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARRJCT" b2="138 KV" b3="ART-WYL" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ARROYO" b2="138 KV" b3="1093" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELIVERP2" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIVERP2" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIVERP2" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ELIVERP2" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIVERP2" b2="138 KV" b3="ELI-SCH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCHESTER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="B37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYLIERID" b2="138 KV" b3="W3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100195</SeqNum>
    <Name>L138.Albright-Kingwood.100 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-01-31T15:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBRIGHT" b2="138 KV" b3="KINGWOOD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ALBRIGHT" b2="138 KV" b3="KINGWRES" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALBRIGHT" b2="138 KV" b3="ALB-KIN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KINGWOOD" b2="138 KV" b3="ALBRIGHT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100196</SeqNum>
    <Name>L138.Kingwood-Pruntytown.100 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-25T11:18:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KINGWOOD" b2="138 KV" b3="KIN-PRU" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KINGWOOD" b2="138 KV" b3="PRUNTYTO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRUNTYTO" b2="138 KV" b3="P13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100197</SeqNum>
    <Name>L138.OakPark-KelsoGap (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-06T13:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSOGAP" b2="138 KV" b3="1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSOGAP" b2="138 KV" b3="3 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="KELSOGAP" b2="138 KV" b3="KEL-OAK" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OAKPARK" b2="138 KV" b3="KELSOGAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100198</SeqNum>
    <Name>L138.Albright-SnowyCreek-OakPark (Sctnlz)</Name>
    <LastEdit Timestamp="2025-12-18T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBRIGHT" b2="138 KV" b3="ALB-SNO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBRIGHT" b2="138 KV" b3="SNOWYCRE" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKPARK" b2="138 KV" b3="OAK-SNO" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OAKPARK" b2="138 KV" b3="SNOWYCRE" />
      <ContingencyEquipment Action="X" Type="XF" b1="SNOWYCRE" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SNOWYCRE" b2="138 KV" b3="SNO-SNOW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SNOWYCRE" b2="69 KV" b3="T1_LO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100199</SeqNum>
    <Name>L138.Reid-Antrim (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-06T13:19:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ANTRIM" b2="138 KV" b3="ANT-REI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ANTRIM" b2="138 KV" b3="REID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REID" b2="138 KV" b3="B15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100200</SeqNum>
    <Name>L138.Antrim-Guilford (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-06T13:19:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ANTRIM" b2="138 KV" b3="ANT-GUI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ANTRIM" b2="138 KV" b3="GUILFORD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUILFORD" b2="138 KV" b3="B137" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100202</SeqNum>
    <Name>L138.VanNess-Harrison.13825</Name>
    <LastEdit Timestamp="2025-02-07T12:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISN" b2="138 KV" b3="2B" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRISN" b2="138 KV" b3="HAR-VAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARRISN" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VANNESS" b2="138 KV" b3="4BB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VANNESS" b2="138 KV" b3="LOAD T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100203</SeqNum>
    <Name>L138.DillesBottom-GeorgeWashington</Name>
    <LastEdit Timestamp="2025-02-07T12:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DILLESBO" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DILLESBO" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DILLESBO" b2="138 KV" b3="DIL-GEO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="138 KV" b3="Q1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100204</SeqNum>
    <Name>L345.Nevada-GoodingsGrove.9806</Name>
    <LastEdit Timestamp="2025-02-07T12:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="116 GOOD" b2="345 KV" b3="GOO-NEVA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="116 GOOD" b2="345 KV" b3="L9806" />
      <ContingencyEquipment Action="OP" Type="CB" b1="98 NEVAD" b2="345 KV" b3="BT 1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="98 NEVAD" b2="345 KV" b3="BT 1-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100205</SeqNum>
    <Name>L345.Nevada-OtterCreek.97501 + OtterCreekWF</Name>
    <LastEdit Timestamp="2025-02-07T12:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="975 OTTE" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="975 OTTE" b2="34.5 KV" b3="CAP2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="975 OTTE" b2="34.5 KV" b3="OTTERWF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="975 OTTE" b2="34.5 KV" b3="STATCOM" />
      <ContingencyEquipment Action="X" Type="XF" b1="975 OTTE" b2="345 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="975 OTTE" b2="345 KV" b3="T1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="98 NEVAD" b2="345 KV" b3="BT 1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="98 NEVAD" b2="345 KV" b3="BT 2-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="98 NEVAD" b2="345 KV" b3="NEV-OTTE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100206</SeqNum>
    <Name>L138.Corridor-GreenChapel</Name>
    <LastEdit Timestamp="2025-05-21T13:44:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="104C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="104S" />
      <ContingencyEquipment Action="L" Type="LN" b1="CORRIDOR" b2="138 KV" b3="COR-GREE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008L5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100207</SeqNum>
    <Name>L230.Stonewater-Thunderball.2308A</Name>
    <LastEdit Timestamp="2024-10-28T16:01:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STNEWATR" b2="230 KV" b3="230862-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STNEWATR" b2="230 KV" b3="230862-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="STNEWATR" b2="230 KV" b3="STO-THUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THUNDERB" b2="230 KV" b3="230842-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THUNDERB" b2="230 KV" b3="230842-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100208</SeqNum>
    <Name>DTX115.Bedford.Load1</Name>
    <LastEdit Timestamp="2026-02-12T15:01:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD" b2="115 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD" b2="115 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD" b2="115 KV" b3="B37" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEDFORD" b2="115 KV" b3="LOAD 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100209</SeqNum>
    <Name>DTX115.BedfordNorth.WILLSAEC</Name>
    <LastEdit Timestamp="2025-04-30T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD" b2="115 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD" b2="115 KV" b3="B34" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEDFORD" b2="115 KV" b3="WILLSAEC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100210</SeqNum>
    <Name>L138.CommonwealthCrossing-Sheffield-Ridgeway</Name>
    <LastEdit Timestamp="2025-02-07T11:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COMMONWC" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="COMMONWC" b2="138 KV" b3="COM-SHEF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGEWAY" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIDGEWAY" b2="138 KV" b3="RID-SHE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHEFFIEL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100211</SeqNum>
    <Name>L138.MtZion-Longbrch-Boone</Name>
    <LastEdit Timestamp="2025-05-27T17:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOONECO" b2="138 KV" b3="CB814" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BOONECO" b2="138 KV" b3="SW817" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LONGBRCH" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LONGBRCH" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONGBRCH" b2="138 KV" b3="LON-BOO" />
      <ContingencyEquipment Action="L" Type="LN" b1="MT_ZION1" b2="138 KV" b3="MTZ-LON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MT_ZION1" b2="138 KV" b3="874" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100212</SeqNum>
    <Name>L138.AKSteel-Garver.606</Name>
    <LastEdit Timestamp="2025-02-07T11:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AKSTL606" b2="138 KV" b3="638" />
      <ContingencyEquipment Action="L" Type="LN" b1="AKSTL606" b2="138 KV" b3="AKS-GARV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="138 KV" b3="871" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARVER" b2="138 KV" b3="873" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100213</SeqNum>
    <Name>L138.Armco1C-AKSTeel602-AKSteel606.1</Name>
    <LastEdit Timestamp="2025-02-07T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AKSTL602" b2="138 KV" b3="602LD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AKSTL602" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AKSTL606" b2="138 KV" b3="634" />
      <ContingencyEquipment Action="L" Type="LN" b1="AKSTL602" b2="138 KV" b3="AKS-AKS1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AKSTL606" b2="138 KV" b3="BK25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMCO_1C" b2="138 KV" b3="625" />
      <ContingencyEquipment Action="L" Type="LN" b1="AKSTL602" b2="138 KV" b3="AKS-ARM1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100214</SeqNum>
    <Name>L138.Armco1C-AKSTeel602-AKSteel606.2</Name>
    <LastEdit Timestamp="2025-02-07T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AKSTL602" b2="138 KV" b3="602LD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AKSTL602" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AKSTL606" b2="138 KV" b3="634" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AKSTL606" b2="138 KV" b3="638" />
      <ContingencyEquipment Action="L" Type="LN" b1="AKSTL602" b2="138 KV" b3="AKS-AKS2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AKSTL606" b2="138 KV" b3="BK26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARMCO_1C" b2="138 KV" b3="624" />
      <ContingencyEquipment Action="L" Type="LN" b1="AKSTL602" b2="138 KV" b3="AKS-ARM2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100215</SeqNum>
    <Name>L138.SouthUnion-Gans-LakeLynn (Sctnlz)</Name>
    <LastEdit Timestamp="2025-09-15T16:39:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GANS" b2="138 KV" b3="GAN-LAK" />
      <ContingencyEquipment Action="L" Type="LN" b1="GANS" b2="138 KV" b3="GAN-SUN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GANS" b2="138 KV" b3="GEN 8" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GANS" b2="138 KV" b3="GEN 9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GANS" b2="138 KV" b3="GEN CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GANS" b2="138 KV" b3="GEN8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GANS" b2="138 KV" b3="GEN9 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GANS" b2="138 KV" b3="SS LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKELYNN" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUNION" b2="138 KV" b3="GANS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100216</SeqNum>
    <Name>L138.Bethelboro-NrthUnion-SouthUnion (Sctnlz)</Name>
    <LastEdit Timestamp="2024-08-20T09:42:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHELBO" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHELBO" b2="138 KV" b3="BET-NUT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GANS" b2="138 KV" b3="GEN 8" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GANS" b2="138 KV" b3="GEN 9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GANS" b2="138 KV" b3="GEN CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GANS" b2="138 KV" b3="SS LOAD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NUNION" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NUNION" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="L" Type="LN" b1="NUNION" b2="138 KV" b3="NUN-NUT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NUTAP2" b2="138 KV" b3="NUT-SUN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUNION" b2="138 KV" b3="NU TP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100217</SeqNum>
    <Name>L138.Bedington-Nipetown (Sctnlz)</Name>
    <LastEdit Timestamp="2026-06-09T08:19:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDINGTO" b2="138 KV" b3="BD16" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEDINGTO" b2="138 KV" b3="BED-NIP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NIPETOWN" b2="138 KV" b3="A1360" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100218</SeqNum>
    <Name>L138.Nipetown-Reid (Sctnlz)</Name>
    <LastEdit Timestamp="2024-11-20T10:51:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="NIPETOWN" b2="138 KV" b3="A1361" />
      <ContingencyEquipment Action="L" Type="LN" b1="NIPETOWN" b2="138 KV" b3="NIP-REI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REID" b2="138 KV" b3="NIPETOWN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100219</SeqNum>
    <Name>L115.Pickens-Durbin-Beverly.158 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-16T11:04:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEVERLY" b2="138 KV" b3="BEV-DUR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BEVERLY" b2="138 KV" b3="DURBIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DURBIN" b2="69 KV" b3="152" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DURBIN" b2="69 KV" b3="166" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DURBIN" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DURBIN" b2="138 KV" b3="DUR-DUR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DURBIN" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="DURBIN" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PICKENS" b2="138 KV" b3="B25" />
      <ContingencyEquipment Action="L" Type="LN" b1="DURBINTP" b2="138 KV" b3="DUR-PIC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100220</SeqNum>
    <Name>L115.Beverly-LoughsLane.158 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-25T12:45:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEVERLY" b2="138 KV" b3="BEV-LOU" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BEVERLY" b2="138 KV" b3="LOUGHSLA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DURBIN" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DURBIN" b2="138 KV" b3="CAP1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUGHSLA" b2="138 KV" b3="B45" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LOUGHSLA" b2="138 KV" b3="BEVERRES" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100221</SeqNum>
    <Name>L138.Backfork-Cowen.172 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-07T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BACKFORK" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BACKFORK" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BACKFORK" b2="138 KV" b3="BAC-COW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COWEN" b2="138 KV" b3="BACKFORK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100222</SeqNum>
    <Name>L138.Cowen-Crupperneck.172 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-07T11:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COWEN" b2="138 KV" b3="COW-CRU" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COWEN" b2="138 KV" b3="CRUPPERN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRUPPERN" b2="138 KV" b3="COWEN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100223</SeqNum>
    <Name>L138.Brookhaven-SMorgantwn (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-07T11:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKHAV" b2="138 KV" b3="BRO-SMO" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKHAV" b2="138 KV" b3="SABRATON" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMORGANT" b2="138 KV" b3="SABRATON" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100224</SeqNum>
    <Name>L138.SMorgantwn-Pricehill (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-07T12:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PRICEHIL" b2="138 KV" b3="B132" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRICEHIL" b2="138 KV" b3="PRI-SMO" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMORGANT" b2="138 KV" b3="PRICEHIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100225</SeqNum>
    <Name>L138.Burma-Clarion (Sctnlz)</Name>
    <LastEdit Timestamp="2025-12-30T11:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURMA" b2="138 KV" b3="B26" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURMA" b2="138 KV" b3="BUR-CLA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLARION" b2="138 KV" b3="BURMA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100226</SeqNum>
    <Name>L138.Clarion-Ridgeway (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-09T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLARION" b2="138 KV" b3="RIDGWAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDG APS" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLARION" b2="138 KV" b3="CLA-RID" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100227</SeqNum>
    <Name>L138.BarnettsRun-BridgeportHill.406 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-07T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BARNETTS" b2="138 KV" b3="BAR-BRI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARNETTS" b2="138 KV" b3="BRIDGECB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRID APS" b2="138 KV" b3="BARNETTS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100228</SeqNum>
    <Name>L138.BridgeportHill-GlenFalls.406 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-05-12T14:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRID APS" b2="138 KV" b3="BRI-GLE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRID APS" b2="138 KV" b3="GLENFALL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENFALL" b2="138 KV" b3="B406" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100229</SeqNum>
    <Name>L138.BlackOak-ShortGap.RJU (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-30T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKOAK" b2="138 KV" b3="BLA-SHO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKOAK" b2="138 KV" b3="BO12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKOAK" b2="138 KV" b3="BO13" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHORTGAP" b2="138 KV" b3="BLACKOAK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100230</SeqNum>
    <Name>L138.ShortGap-Cumberland.RJU (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-07T12:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CUMB APS" b2="138 KV" b3="CUM-SHO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB APS" b2="138 KV" b3="SHORTGAP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHORTGAP" b2="138 KV" b3="CUMBERLA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100233</SeqNum>
    <Name>L138.Cabot-Woodland-NPointe (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-10T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABOT" b2="138 KV" b3="C9" />
      <ContingencyEquipment Action="L" Type="LN" b1="CABOT" b2="138 KV" b3="CAB-WOO" />
      <ContingencyEquipment Action="L" Type="LN" b1="NPOINTE2" b2="138 KV" b3="NPO-WOO" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NPOINTE2" b2="138 KV" b3="WOODLAND" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODLAND" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100234</SeqNum>
    <Name>L138.NPointe-KiskiValley (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-10T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KISKIVAL" b2="138 KV" b3="KIS-NPO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KISKIVAL" b2="138 KV" b3="NPOINTE2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NPOINTE2" b2="138 KV" b3="KISKIVAL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100235</SeqNum>
    <Name>L138.Catoctin-Walkersville (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-10T11:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CATOCTIN" b2="138 KV" b3="CAT-WAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CATOCTIN" b2="138 KV" b3="WALKERSV" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WALKERSV" b2="138 KV" b3="CATOCTIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100236</SeqNum>
    <Name>L138.Walkersville-Monocacy (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-10T11:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MONOCACY" b2="138 KV" b3="MON-WAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONOCACY" b2="138 KV" b3="WALKERSV" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WALKERSV" b2="138 KV" b3="MONOCACY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100237</SeqNum>
    <Name>L138.Weirton-Hamilton-Parkview.200 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-14T11:26:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HAMI APS" b2="138 KV" b3="HAM-PAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAMI APS" b2="138 KV" b3="HAM-WEI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAMI APS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAMI APS" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PARKVIEW" b2="138 KV" b3="HAMILTON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WEIRTON" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100238</SeqNum>
    <Name>L138.Parkview-BufaloJct-Cecil-Windsor.200 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-10T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BUFFAJCT" b2="138 KV" b3="BUF-CEC" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUFFAJCT" b2="138 KV" b3="BUF-PAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUFFAJCT" b2="138 KV" b3="BUF-WIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CECI APS" b2="138 KV" b3="BUFFAJCT" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PARKVIEW" b2="138 KV" b3="BUFFALOJ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND APS" b2="138 KV" b3="BUFFAJCT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100239</SeqNum>
    <Name>L138.CrupperNeck-Craigsville.302 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-10T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CRAIGSVI" b2="138 KV" b3="CRUPPERN" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRAIGSVI" b2="138 KV" b3="CRA-CRU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRUPPERN" b2="138 KV" b3="CRAIGSVI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100240</SeqNum>
    <Name>L138.Craigsville-PowellMT.302 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-10T11:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CRAIGSVI" b2="138 KV" b3="POWELLMO" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRAIGSVI" b2="138 KV" b3="CRA-POW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POWELLMT" b2="138 KV" b3="CRAIGSVI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100241</SeqNum>
    <Name>L230.Bremo-ForkUnion.2193 </Name>
    <LastEdit Timestamp="2026-01-06T11:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="230 KV" b3="219322" />
      <ContingencyEquipment Action="L" Type="LN" b1="BREMO4" b2="230 KV" b3="2193A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BREMO4" b2="34.5 KV" b3="TX5LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="BREMO4" b2="230 KV" b3="TX5_" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRKUNION" b2="230 KV" b3="20282193" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRKUNION" b2="230 KV" b3="WT2193" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100242</SeqNum>
    <Name>230/138.ForkUnion.TX1</Name>
    <LastEdit Timestamp="2025-04-10T15:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRKUNION" b2="230 KV" b3="H172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRKUNION" b2="115 KV" b3="L172" />
      <ContingencyEquipment Action="X" Type="XF" b1="FRKUNION" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100244</SeqNum>
    <Name>L345.Wellsville-Sammis</Name>
    <LastEdit Timestamp="2025-11-07T15:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="345 KV" b3="278" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAMMISFE" b2="345 KV" b3="280" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAMMISFE" b2="345 KV" b3="SAM-WELL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLSVIL" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLSVIL" b2="345 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100246</SeqNum>
    <Name>L138.NewMartinsville-PadenCity.68 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWMARTI" b2="138 KV" b3="HANN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWMARTI" b2="138 KV" b3="HANN NUG" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWMARTI" b2="138 KV" b3="NEW-PAD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NEWMARTI" b2="138 KV" b3="PADENCIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADENCIT" b2="138 KV" b3="NEWMARTI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100247</SeqNum>
    <Name>L138.Natrium-NewMartinsville.68 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NATRIUM2" b2="138 KV" b3="M3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWMARTI" b2="138 KV" b3="HANN CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEWMARTI" b2="138 KV" b3="HANN NUG" />
      <ContingencyEquipment Action="L" Type="LN" b1="NATRIUM2" b2="138 KV" b3="NAT-NEW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NEWMARTI" b2="138 KV" b3="NATRIUM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100248</SeqNum>
    <Name>L230.Monocacy-OldFarm.219 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-06-26T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MONOCACY" b2="230 KV" b3="MON-OLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONOCACY" b2="230 KV" b3="OLDFARM" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OLDFARM" b2="230 KV" b3="MONOCACY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100249</SeqNum>
    <Name>L230.OldFarm-RingGold.219 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-06-26T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="OLDFARM" b2="230 KV" b3="OLD-RIN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OLDFARM" b2="230 KV" b3="RINGGOLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RINGGOLD" b2="230 KV" b3="MONOCACY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100250</SeqNum>
    <Name>L138.Springdale-MurryCrest (Sctnlz)</Name>
    <LastEdit Timestamp="2025-12-29T10:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MURRYCRE" b2="138 KV" b3="SPRINGDA" />
      <ContingencyEquipment Action="L" Type="LN" b1="MURRYCRE" b2="138 KV" b3="MUR-SPR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="MURRYCRE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100251</SeqNum>
    <Name>L138.MurryCrest-Sunoco-WhiteValley (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-20T13:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MURRYCRE" b2="138 KV" b3="MUR-SUN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MURRYCRE" b2="138 KV" b3="SUNOCO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNDELMT" b2="138 KV" b3="SUNOCO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEVAL" b2="138 KV" b3="SPRING" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUNDELMT" b2="138 KV" b3="SUN-WHI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100252</SeqNum>
    <Name>L138.Whiteley-Blacksville.MiracleRun (Sctnlz)</Name>
    <LastEdit Timestamp="2024-11-21T15:05:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKSVI" b2="138 KV" b3="BLA-MIR" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKSVI" b2="138 KV" b3="BLA-WHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKSVI" b2="138 KV" b3="BLACK CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLACKSVI" b2="138 KV" b3="BLACKSVI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLACKSVI" b2="138 KV" b3="CONSOL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKSVI" b2="138 KV" b3="CONSOLCB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MIRACLER" b2="138 KV" b3="CS1022DS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITELEY" b2="138 KV" b3="BLACK CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100253</SeqNum>
    <Name>L138.MiracleRun-Fairview (Sctnlz)</Name>
    <LastEdit Timestamp="2025-11-25T16:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIR APS" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAIR APS" b2="138 KV" b3="FAI-MIR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MIRACLER" b2="138 KV" b3="A1013" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100254</SeqNum>
    <Name>L138.WWinchester-Redbud.MRB2</Name>
    <LastEdit Timestamp="2026-05-15T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="REDBUD" b2="138 KV" b3="RED-WWI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBUD" b2="138 KV" b3="WWINCHES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWINCHES" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WWINCHES" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WWINCHES" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100255</SeqNum>
    <Name>Cedar.SVC</Name>
    <LastEdit Timestamp="2025-02-20T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CEDAR" b2="230 KV" b3="CED_SVC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="230 KV" b3="VV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100256</SeqNum>
    <Name>Monocacy.SVC</Name>
    <LastEdit Timestamp="2025-04-18T17:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONOCACY" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MONOCACY" b2="230 KV" b3="BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MONOCACY" b2="230 KV" b3="BUCK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MONOCACY" b2="230 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100257</SeqNum>
    <Name>WaldoRun.SVC</Name>
    <LastEdit Timestamp="2025-02-20T13:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="10" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WALDORUN" b2="138 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100258</SeqNum>
    <Name>CaneRiver.SVC</Name>
    <LastEdit Timestamp="2025-04-18T17:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CANERIV" b2="230 KV" b3="BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CANERIV" b2="230 KV" b3="BUCK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANERIV" b2="230 KV" b3="CRAGCSVC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANERIV" b2="230 KV" b3="CSVC_BK2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CANERIV" b2="230 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100259</SeqNum>
    <Name>Colington.SVC</Name>
    <LastEdit Timestamp="2025-02-20T12:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="COLINGTN" b2="115 KV" b3="BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COLINGTN" b2="115 KV" b3="BUCK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COLINGTN" b2="115 KV" b3="SV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLINGTN" b2="115 KV" b3="SV132" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100260</SeqNum>
    <Name>Fentress.SVC</Name>
    <LastEdit Timestamp="2025-02-14T14:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="FENTRES4" b2="230 KV" b3="BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FENTRES4" b2="230 KV" b3="BUCK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FENTRES4" b2="230 KV" b3="SV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="SV122" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100261</SeqNum>
    <Name>Landstown.SVC</Name>
    <LastEdit Timestamp="2025-02-18T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="LANDSTWN" b2="230 KV" b3="BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LANDSTWN" b2="230 KV" b3="BUCK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LANDSTWN" b2="230 KV" b3="SV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="230 KV" b3="SV152" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100262</SeqNum>
    <Name>Lynnhaven.SVC</Name>
    <LastEdit Timestamp="2025-02-18T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="LYNNHAVN" b2="230 KV" b3="BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LYNNHAVN" b2="230 KV" b3="BUCK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LYNNHAVN" b2="230 KV" b3="SV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNNHAVN" b2="230 KV" b3="SV182" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100263</SeqNum>
    <Name>Mosby.SVC1</Name>
    <LastEdit Timestamp="2025-02-18T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MOSBY" b2="500 KV" b3="BOOST1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOSBY" b2="500 KV" b3="BUCK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSBY" b2="500 KV" b3="SV172" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOSBY" b2="500 KV" b3="SVC_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100264</SeqNum>
    <Name>Mosby.SVC2</Name>
    <LastEdit Timestamp="2025-02-20T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MOSBY" b2="500 KV" b3="BOOST2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOSBY" b2="500 KV" b3="BUCK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSBY" b2="500 KV" b3="SV272" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOSBY" b2="500 KV" b3="SVC2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100265</SeqNum>
    <Name>NorthernNeck.SVC</Name>
    <LastEdit Timestamp="2025-02-20T13:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="NRTHNECK" b2="115 KV" b3="BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NRTHNECK" b2="115 KV" b3="BUCK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="115 KV" b3="M4222" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NRTHNECK" b2="115 KV" b3="SV1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100266</SeqNum>
    <Name>Atlantic.STATCOM</Name>
    <LastEdit Timestamp="2024-08-20T09:15:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLANTIC" b2="230 KV" b3="B61" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ATLANTIC" b2="230 KV" b3="SVS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100268</SeqNum>
    <Name>L230.Hopewell-PleasentValley(PS).E-1019</Name>
    <LastEdit Timestamp="2025-02-20T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL1" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL1" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPEWEL1" b2="230 KV" b3="HOP-PLVY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLVY PS" b2="230 KV" b3="SECT2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100269</SeqNum>
    <Name>L138.Gordon-Lagonda (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-20T13:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GORDON" b2="138 KV" b3="GOR-LAG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDON" b2="138 KV" b3="LAGONDA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAGONDA" b2="138 KV" b3="GORDON" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100270</SeqNum>
    <Name>L138.Lagonda-WindsorAPS (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAGONDA" b2="138 KV" b3="WINDSOR" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAGONDA" b2="138 KV" b3="LAG-WIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND APS" b2="138 KV" b3="LAGONDA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100271</SeqNum>
    <Name>L138.Luxor-EastGate-Sony (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T12:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="EASTGATE" b2="138 KV" b3="LUXOSONY" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTGATE" b2="138 KV" b3="EAS-LUX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUXOR" b2="138 KV" b3="EASTGATE" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTGATE" b2="138 KV" b3="EAS-SON" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SONY" b2="138 KV" b3="EASTGATE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100272</SeqNum>
    <Name>L138.Sony-KingFarm (Sctnlz)</Name>
    <LastEdit Timestamp="2024-05-21T15:08:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGFARM" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGFARM" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="L" Type="LN" b1="KINGFARM" b2="138 KV" b3="KIN-SON" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SONY" b2="138 KV" b3="KINGFARM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100273</SeqNum>
    <Name>L138.Huntingdon-Robbins (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-20T13:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTINGD" b2="138 KV" b3="HUN-ROB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTINGD" b2="138 KV" b3="ROBBINS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROBBINS" b2="138 KV" b3="HUNTINGD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100274</SeqNum>
    <Name>L138.Robbins-Yukon (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T12:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROBBINS" b2="138 KV" b3="YUKON" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROBBINS" b2="138 KV" b3="ROB-YUK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="Y7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="Y8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100275</SeqNum>
    <Name>L138.Hempfield-Sewickley (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-20T13:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HEMPFIEL" b2="138 KV" b3="HEM-SEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEMPFIEL" b2="138 KV" b3="SEWICKLE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SEWICKLE" b2="138 KV" b3="HEMPFIEL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100276</SeqNum>
    <Name>L138.Sewickley-WaltzMill-Yukon (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-25T11:27:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SEWICKLE" b2="138 KV" b3="SEW-WAL" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SEWICKLE" b2="138 KV" b3="WALTZMIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALTZMIL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="WALTZMIL" b2="138 KV" b3="WAL-YUK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="Y7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100277</SeqNum>
    <Name>L138.Hempfield-NGreensburg (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-20T17:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEMPFIEL" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEMPFIEL" b2="138 KV" b3="HEM-NGR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NGREENSB" b2="138 KV" b3="HEMPFIEL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100278</SeqNum>
    <Name>L138.NGreensburg-Luxor-Oak-Penn-Harrison(Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T08:27:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HARRCITY" b2="138 KV" b3="HAR-PEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRCITY" b2="138 KV" b3="PENN" />
      <ContingencyEquipment Action="L" Type="LN" b1="LUXOR" b2="138 KV" b3="LUX-STO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUXOR" b2="138 KV" b3="STOSPJCT" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NGREENSB" b2="138 KV" b3="STOSPJCT" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELLIOTTP" b2="138 KV" b3="ELL-NOAK" />
      <ContingencyEquipment Action="L" Type="LN" b1="NOAKFORD" b2="138 KV" b3="NOA-SOA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NOAKFORD" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELLIOTTP" b2="138 KV" b3="ELL-PENN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENN APS" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOAKFORD" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="L" Type="LN" b1="NGREENSB" b2="138 KV" b3="NGR-STO" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOAKFORD" b2="138 KV" b3="SOA-STO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100279</SeqNum>
    <Name>500/230.Conemaugh.TX3</Name>
    <LastEdit Timestamp="2025-01-16T12:40:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONEMAUG" b2="500 KV" b3="B54" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONEMAUG" b2="230 KV" b3="B57" />
      <ContingencyEquipment Action="X" Type="XF" b1="CONEMAUG" b2="500 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100280</SeqNum>
    <Name>L138.Finzel-Frostburg (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T12:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FINZEL" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINZEL" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FINZEL" b2="138 KV" b3="FIN-FRO" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FROSTBU1" b2="138 KV" b3="FINZEL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100281</SeqNum>
    <Name>L138.Frostburg-Ridgeley (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T12:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FROSTBU1" b2="138 KV" b3="RIDGELEY" />
      <ContingencyEquipment Action="L" Type="LN" b1="FROSTBU1" b2="138 KV" b3="FRO-RID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGELEY" b2="138 KV" b3="FROSTBUR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100282</SeqNum>
    <Name>L138.Mechanicstown-FeagansMill (Sctnlz)</Name>
    <LastEdit Timestamp="2024-11-20T10:55:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FEAGANSM" b2="138 KV" b3="A3" />
      <ContingencyEquipment Action="L" Type="LN" b1="FEAGANSM" b2="138 KV" b3="FEA-MEC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MECHATWN" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MECHATWN" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100283</SeqNum>
    <Name>L138.FeagansMill-Stonewall (Sctnlz)</Name>
    <LastEdit Timestamp="2024-11-20T10:55:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FEAGANSM" b2="138 KV" b3="A4" />
      <ContingencyEquipment Action="L" Type="LN" b1="FEAGANSM" b2="138 KV" b3="FEA-STO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STONEWAL" b2="138 KV" b3="B7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100284</SeqNum>
    <Name>L138.GrandPt-Fayetteville (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T12:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FAYETTEV" b2="138 KV" b3="FAY-GRA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAYETTEV" b2="138 KV" b3="GRANDPOI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDPT" b2="138 KV" b3="FAYETTEV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100285</SeqNum>
    <Name>L138.Fayetteville-WestWaynesboro (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T14:52:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FAYETTEV" b2="138 KV" b3="FAY-WWA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAYETTEV" b2="138 KV" b3="W WAYNES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWAYNESB" b2="138 KV" b3="FAYETTEV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100286</SeqNum>
    <Name>L138.Fairview-GrantTown.42 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-29T12:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAIR APS" b2="138 KV" b3="GRANTRES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIR APS" b2="138 KV" b3="GRANTTOW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GRANTTOW" b2="138 KV" b3="1261_Q" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRANTTOW" b2="18 KV" b3="ABPP NUG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANTTOW" b2="138 KV" b3="AM_BITUM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRANTTOW" b2="138 KV" b3="AUX_LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAIR APS" b2="138 KV" b3="FAI-GRA" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRANTTOW" b2="138 KV" b3="GSU 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100287</SeqNum>
    <Name>L138.GrantTown-Rivesville.42 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-18T15:38:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GRANTTOW" b2="138 KV" b3="1260_Q" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GRANTTOW" b2="18 KV" b3="ABPP NUG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANTTOW" b2="138 KV" b3="AM_BITUM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRANTTOW" b2="138 KV" b3="AUX_LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANTTOW" b2="138 KV" b3="GRA-RIV" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRANTTOW" b2="138 KV" b3="GSU 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVESVIL" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100288</SeqNum>
    <Name>L138.Gilboa-Enon-Powell-Summersville (Sctnlz)</Name>
    <LastEdit Timestamp="2026-03-30T18:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ENONTP" b2="138 KV" b3="ENO-GIL" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENONTP" b2="138 KV" b3="ENO-POW" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENONTP" b2="138 KV" b3="ENO-SUM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILB APS" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POWELLMT" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUMMERSV" b2="138 KV" b3="ENONTAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100289</SeqNum>
    <Name>L138.Summersville-GrassyFalls (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-23T09:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRASSYFA" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRASSYFA" b2="138 KV" b3="GRA-SUM" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUMMERSV" b2="138 KV" b3="GRASSYFA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100291</SeqNum>
    <Name>L138.Lardin-ClarksvllJct-Maldn-Californ (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-29T12:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CALIFORN" b2="138 KV" b3="CAL-MAL" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CALIFORN" b2="138 KV" b3="MALDEN" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLRKSJCT" b2="138 KV" b3="CLA-EME" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLRKSJCT" b2="138 KV" b3="CLA-LAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLRKSJCT" b2="138 KV" b3="CLA-LUZ" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EMERALD" b2="138 KV" b3="CLARKS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARDIN" b2="138 KV" b3="L-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARDIN" b2="138 KV" b3="L-5" />
      <ContingencyEquipment Action="L" Type="LN" b1="LUZERNE" b2="138 KV" b3="LUZ-MAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LUZERNE" b2="138 KV" b3="T62" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MALDEN" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100292</SeqNum>
    <Name>L138.Californ-Charlero (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-24T11:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CALIFORN" b2="138 KV" b3="CAL-CHA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CALIFORN" b2="138 KV" b3="CHARLERO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLERO" b2="138 KV" b3="CALIFORN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100293</SeqNum>
    <Name>L138.Charleroi-WestRaver (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-24T11:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLERO" b2="138 KV" b3="WESTRAVE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHARLERO" b2="138 KV" b3="CHA-WES" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WESTRAVE" b2="138 KV" b3="CHARLERO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100294</SeqNum>
    <Name>L138.WestRaver-Yukon (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="WESTRAVE" b2="138 KV" b3="WES-YUK" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WESTRAVE" b2="138 KV" b3="YUKON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="Y18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="Y19" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100295</SeqNum>
    <Name>L138.Albright-Ruthbelle.102 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-24T11:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBRIGHT" b2="138 KV" b3="ALB-RUT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBRIGHT" b2="138 KV" b3="RUTHBELL" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ALBRIGHT" b2="138 KV" b3="RUTHBRES" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RUTHBELL" b2="138 KV" b3="ALBRIGHT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100296</SeqNum>
    <Name>L138.Ruthbelle-CheatLake.102 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHTLAKE" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHTLAKE" b2="138 KV" b3="CHT-RUT" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RUTHBELL" b2="138 KV" b3="CHTLAKE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100297</SeqNum>
    <Name>L138.LakeLynn-CheatLake (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-24T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHTLAKE" b2="138 KV" b3="CHT-LAK" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHTLAKE" b2="138 KV" b3="LAKELYNN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKELYNN" b2="138 KV" b3="CHEATLAK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100298</SeqNum>
    <Name>138/69.CheatLake.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-25T15:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CHTLAKE" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHTLAKE" b2="69 KV" b3="SNOW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHTLAKE" b2="138 KV" b3="T4 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100299</SeqNum>
    <Name>L138.LakeLynn-WestRun.14 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-24T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LAKELYNN" b2="138 KV" b3="LAK-WES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKELYNN" b2="138 KV" b3="W RUN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WESTRUN" b2="138 KV" b3="LAKELYNN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100300</SeqNum>
    <Name>L138.WestRun-CollinsFerry.14 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLLINSF" b2="138 KV" b3="COL-WES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLINSF" b2="138 KV" b3="WRUN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WESTRUN" b2="138 KV" b3="COLLINSF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100301</SeqNum>
    <Name>L138.SenecaCaverns-CanaanValley.160 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CANAANVA" b2="138 KV" b3="SENECACA" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANAANVA" b2="138 KV" b3="CAN-SEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SENECACA" b2="138 KV" b3="CANAANVA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100302</SeqNum>
    <Name>L138.CanaanValley-William.160 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-24T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CANAANVA" b2="138 KV" b3="WILLIAM" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANAANVA" b2="138 KV" b3="CAN-WIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLIAM" b2="138 KV" b3="CANAANVA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WILLIAM" b2="138 KV" b3="CANAARES" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100303</SeqNum>
    <Name>L138.Everson-Chesapeake.400 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-24T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHESAPEA" b2="138 KV" b3="A1087" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESAPEA" b2="138 KV" b3="CHE-EVE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERSON" b2="138 KV" b3="CHESAPEA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100304</SeqNum>
    <Name>L138.Chesapeake-Rivesville.400 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-24T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHESAPEA" b2="138 KV" b3="A1086" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVESVIL" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESAPEA" b2="138 KV" b3="CHE-RIV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100305</SeqNum>
    <Name>L115.Carroll-Taneytown (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-24T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARROLL" b2="138 KV" b3="TANEYTOW" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARROLL" b2="138 KV" b3="CAR-TAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TANEYTOW" b2="138 KV" b3="CARROLL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100306</SeqNum>
    <Name>L115.Taneytown-Germantown (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-29T12:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GERMANTO" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="GERMANTO" b2="138 KV" b3="GER-TAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TANEYTOW" b2="138 KV" b3="GERMANTO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100307</SeqNum>
    <Name>L138.DoubleTollGate-OldChapel (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-24T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBLETO" b2="138 KV" b3="OLDCHAPE" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBLETO" b2="138 KV" b3="DOU-OLD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OLDCHAPE" b2="138 KV" b3="DOUBLETO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100308</SeqNum>
    <Name>L138.OldChapel-Millville (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T12:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLVILL" b2="138 KV" b3="OLDCHAPE" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLVILL" b2="138 KV" b3="MIL-OLD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OLDCHAPE" b2="138 KV" b3="MILLVILL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100309</SeqNum>
    <Name>L138.Dupont-Larkmead (Sctnlz)</Name>
    <LastEdit Timestamp="2025-11-17T15:45:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPONT" b2="138 KV" b3="B92" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUPONT" b2="138 KV" b3="DUP-LAR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DUPONT" b2="138 KV" b3="EDLWN_BP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LARKMEAD" b2="138 KV" b3="A8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100310</SeqNum>
    <Name>L138.Larkmead-Edgelawn (Sctnlz)</Name>
    <LastEdit Timestamp="2025-11-17T15:46:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGELAWN" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDGELAWN" b2="138 KV" b3="EDG-LAR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LARKMEAD" b2="138 KV" b3="A6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100311</SeqNum>
    <Name>L138.Ringgold-EWaynesboro (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T12:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="EWAYNESB" b2="138 KV" b3="RINGGOLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RINGGOLD" b2="138 KV" b3="EASTWAYN" />
      <ContingencyEquipment Action="L" Type="LN" b1="EWAYNESB" b2="138 KV" b3="EWA-RIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100312</SeqNum>
    <Name>L138.EWaynesboro-WWaynesboro (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-24T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="EWAYNESB" b2="138 KV" b3="W WAYNES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWAYNESB" b2="138 KV" b3="E WAYNES" />
      <ContingencyEquipment Action="L" Type="LN" b1="EWAYNESB" b2="138 KV" b3="EWA-WWA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100313</SeqNum>
    <Name>L138.GateHill-BrownsvilleJCT (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-29T12:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROWNJCT" b2="138 KV" b3="BRO-GAT" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROWNJCT" b2="138 KV" b3="DUMGATE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GATESHIL" b2="138 KV" b3="LARDIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GATESHIL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100314</SeqNum>
    <Name>L138.BrownsvilleJCT-Charleroi (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-24T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROWNJCT" b2="138 KV" b3="BRO-CHA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROWNJCT" b2="138 KV" b3="DUMCHAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARLERO" b2="138 KV" b3="EMERALD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100315</SeqNum>
    <Name>L138.Astor-BriceRd</Name>
    <LastEdit Timestamp="2025-02-21T12:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTOR" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ASTOR" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRICE" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRICE" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASTOR" b2="138 KV" b3="AST-BRIC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100316</SeqNum>
    <Name>L138.BriceRd-Refugee-Groves-Shannon</Name>
    <LastEdit Timestamp="2025-03-14T10:29:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRICE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRICE" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GROVES" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRICE" b2="138 KV" b3="BRI-REFU" />
      <ContingencyEquipment Action="L" Type="LN" b1="GROVES" b2="138 KV" b3="GRO-REF" />
      <ContingencyEquipment Action="L" Type="LN" b1="REFUGEE" b2="138 KV" b3="REF-SHA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHANNON" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHANNON" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHANNON" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100317</SeqNum>
    <Name>L138.Belmont-Middlebourne-Jacksonburg (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-21T12:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELMONT" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="138 KV" b3="BEL-MID" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="JACKSONB" b2="138 KV" b3="1088" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSONB" b2="138 KV" b3="JAC-MID" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDDLEBO" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100318</SeqNum>
    <Name>L138.Jacksonburg-RichwoodHill (Sctnlz)</Name>
    <LastEdit Timestamp="2025-02-24T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="JACKSONB" b2="138 KV" b3="1089" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSONB" b2="138 KV" b3="JAC-RIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHWDHL" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHWDHL" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100320</SeqNum>
    <Name>ChaseCity.BlueStSP</Name>
    <LastEdit Timestamp="2025-09-04T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="CHASECTY" b2="115 KV" b3="1027" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHASECTY" b2="115 KV" b3="102712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHASECTY" b2="34.5 KV" b3="BLUESTCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHASECTY" b2="34.5 KV" b3="BLUESTSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHASECTY" b2="115 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100321</SeqNum>
    <Name>230/13.Middletown.T2</Name>
    <LastEdit Timestamp="2025-02-26T14:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD PE" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MIDD PE" b2="230 KV" b3="825 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MIDD PE" b2="230 KV" b3="MID 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100322</SeqNum>
    <Name>Sunbury.Diesel</Name>
    <LastEdit Timestamp="2025-02-26T15:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="SUNBURY" b2="69 KV" b3="DIES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="TR10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="TR10TR23" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100323</SeqNum>
    <Name>230/115.Gordonsville.TX4</Name>
    <LastEdit Timestamp="2025-04-15T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONSV" b2="230 KV" b3="H482" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONSV" b2="115 KV" b3="L482" />
      <ContingencyEquipment Action="X" Type="XF" b1="GORDONSV" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100324</SeqNum>
    <Name>345/138.Kirk.T5</Name>
    <LastEdit Timestamp="2025-02-26T14:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="345 KV" b3="C CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="345 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="138 KV" b3="J2" />
      <ContingencyEquipment Action="X" Type="XF" b1="KIRK" b2="345 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100325</SeqNum>
    <Name>L115.ChaseCity-ButcherCreek.1045</Name>
    <LastEdit Timestamp="2025-02-26T14:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTCHERC" b2="115 KV" b3="104502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTCHERC" b2="115 KV" b3="98T1045" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUTCHERC" b2="115 KV" b3="BUT-CHAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHASECTY" b2="115 KV" b3="104512" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100326</SeqNum>
    <Name>L115.ButcherCreek-Lunenburg.98</Name>
    <LastEdit Timestamp="2025-02-26T14:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTCHERC" b2="115 KV" b3="9802" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTCHERC" b2="115 KV" b3="98T1045" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUNENBRG" b2="115 KV" b3="98T1005" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUNENBRG" b2="115 KV" b3="98T1023" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUTCHERC" b2="115 KV" b3="BUT-LUNE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100327</SeqNum>
    <Name>ButcherCreek.BUTCHSP</Name>
    <LastEdit Timestamp="2025-02-26T16:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTCHERC" b2="115 KV" b3="104502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTCHERC" b2="115 KV" b3="9802" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BUTCHERC" b2="34.5 KV" b3="BUTCHCSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUTCHERC" b2="115 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100328</SeqNum>
    <Name>115/22.BlairsvilleEast.TX2</Name>
    <LastEdit Timestamp="2025-02-26T15:55:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAIRSVE" b2="115 KV" b3="B48" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAIRSVE" b2="115 KV" b3="B55" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLAIRSVE" b2="115 KV" b3="NO.2 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAIRSVE" b2="22 KV" b3="NO2TX22C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100329</SeqNum>
    <Name>115/22.BlairsvilleEast.TX3</Name>
    <LastEdit Timestamp="2025-02-27T16:06:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAIRSVE" b2="115 KV" b3="B45" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAIRSVE" b2="115 KV" b3="B51" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLAIRSVE" b2="115 KV" b3="NO.3 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAIRSVE" b2="22 KV" b3="NO3TX22C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100332</SeqNum>
    <Name>230/13.Emilie.T1</Name>
    <LastEdit Timestamp="2024-08-27T09:40:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="230 KV" b3="15 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EMILIE" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="EMILIE" b2="230 KV" b3="EMIL1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100333</SeqNum>
    <Name>230/35.Windsor.1TR</Name>
    <LastEdit Timestamp="2026-02-10T11:25:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND JC" b2="230 KV" b3="B38" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND JC" b2="230 KV" b3="B57" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND JC" b2="230 KV" b3="B64" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND JC" b2="34.5 KV" b3="B80" />
      <ContingencyEquipment Action="X" Type="XF" b1="WIND JC" b2="230 KV" b3="BK 1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100334</SeqNum>
    <Name>L230.Windsor-Clarksville.C-1017</Name>
    <LastEdit Timestamp="2025-03-24T15:51:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLARKSVI" b2="230 KV" b3="CLA-WIN" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CLARKSVI" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKSVI" b2="230 KV" b3="SECT1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKSVI" b2="230 KV" b3="TRAN4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLARKSVI" b2="230 KV" b3="TRANT-2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="CLARKSVI" b2="230 KV" b3="TRNSFR34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND JC" b2="230 KV" b3="B64" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND JC" b2="230 KV" b3="B68" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100335</SeqNum>
    <Name>115/35.EastTowanda.T5</Name>
    <LastEdit Timestamp="2025-03-28T15:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ETOWANDA" b2="115 KV" b3="5TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="115 KV" b3="B113" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ETOWANDA" b2="34.5 KV" b3="B5TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100336</SeqNum>
    <Name>230/115.Shelocta.TX2 </Name>
    <LastEdit Timestamp="2026-01-28T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELOCTA" b2="230 KV" b3="B37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELOCTA" b2="230 KV" b3="B40" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHELOCTA" b2="230 KV" b3="NO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELOCTA" b2="115 KV" b3="NO2TX115" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100337</SeqNum>
    <Name>230/69.WestShore.TRAN2</Name>
    <LastEdit Timestamp="2025-04-10T15:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WSHORE" b2="230 KV" b3="TRAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHORE" b2="230 KV" b3="TRAN2HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHORE" b2="69 KV" b3="TRAN2LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100340</SeqNum>
    <Name>L138/69.Fremont.T1 + 69.Fremont.Bus</Name>
    <LastEdit Timestamp="2025-07-10T10:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FREMNT" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="FREMNT" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="FREMNT" b2="12 KV" b3="1-T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FREMNT" b2="12 KV" b3="12KV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMNT" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMNT" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMNT" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FREMNT" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FREMNT" b2="69 KV" b3="LD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMNT" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100342</SeqNum>
    <Name>Fieldale.SC1</Name>
    <LastEdit Timestamp="2025-04-22T11:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDALE" b2="138 KV" b3="AF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDALE" b2="138 KV" b3="BT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FIELDALE" b2="13 KV" b3="SYNCHRO8" />
      <ContingencyEquipment Action="X" Type="XF" b1="FIELDALE" b2="138 KV" b3="T8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100343</SeqNum>
    <Name>Fieldale.SC2</Name>
    <LastEdit Timestamp="2025-07-23T16:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDALE" b2="138 KV" b3="AF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDALE" b2="138 KV" b3="BT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FIELDALE" b2="13 KV" b3="SYNCHRO9" />
      <ContingencyEquipment Action="X" Type="XF" b1="FIELDALE" b2="138 KV" b3="T9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100346</SeqNum>
    <Name>L138.Anguin-Babbitt.1</Name>
    <LastEdit Timestamp="2026-03-16T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ANGUIN" b2="138 KV" b3="ANG-BAB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="H1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100347</SeqNum>
    <Name>L138.Anguin-Babbitt.2</Name>
    <LastEdit Timestamp="2026-02-27T15:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ANGUIN" b2="138 KV" b3="ANG-BAB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="H009G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="H009G5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="G1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100348</SeqNum>
    <Name>DTX138.Huffman.T1</Name>
    <LastEdit Timestamp="2025-09-16T13:49:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUFFMAN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUFFMAN" b2="138 KV" b3="AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUFFMAN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUFFMAN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUFFMAN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUFFMAN" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100350</SeqNum>
    <Name>DTX69.Atco.LoadBus1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-05-19T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="ATCO" b2="69 KV" b3="ATCO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ATCO" b2="69 KV" b3="BUS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATCO" b2="69 KV" b3="CAPGCBG" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ATCO" b2="69 KV" b3="K" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100351</SeqNum>
    <Name>DTX69.Clayton.Load1</Name>
    <LastEdit Timestamp="2025-05-28T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLAYTNAE" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLAYTNAE" b2="69 KV" b3="LOADDIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100352</SeqNum>
    <Name>DTX138.Landis.T1</Name>
    <LastEdit Timestamp="2025-07-03T13:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDIS" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDIS" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LANDIS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100353</SeqNum>
    <Name>DTX138.Landis.MANAWAY</Name>
    <LastEdit Timestamp="2025-07-03T13:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDIS" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LANDIS" b2="138 KV" b3="MANAWAY" />
      <ContingencyEquipment Action="S" Type="SD" b1="LANDIS" b2="138 KV" b3="SEREACT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDIS" b2="138 KV" b3="W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100354</SeqNum>
    <Name>DTX138.Lincoln.CLAYVILLE</Name>
    <LastEdit Timestamp="2025-07-07T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINCOLN1" b2="138 KV" b3="CLAYVILL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN1" b2="138 KV" b3="GCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN1" b2="138 KV" b3="GCB B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LINCOLN1" b2="138 KV" b3="MAYSLNSP" />
      <ContingencyEquipment Action="S" Type="SD" b1="LINCOLN1" b2="138 KV" b3="SEREACT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100355</SeqNum>
    <Name>DTX138.Minotola.1BUS</Name>
    <LastEdit Timestamp="2021-04-23T11:24:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MINOTOLA" b2="138 KV" b3="1BUS" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MINOTOLA" b2="138 KV" b3="1BUS" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MINOTOLA" b2="138 KV" b3="CEDARSLR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINOTOLA" b2="138 KV" b3="H CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINOTOLA" b2="138 KV" b3="J CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100356</SeqNum>
    <Name>DTX138.Minotola.2BUS</Name>
    <LastEdit Timestamp="2021-04-23T11:24:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MINOTOLA" b2="138 KV" b3="2BUS" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MINOTOLA" b2="138 KV" b3="2BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINOTOLA" b2="138 KV" b3="K CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINOTOLA" b2="138 KV" b3="M CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100357</SeqNum>
    <Name>DTX138.Union.BUS3</Name>
    <LastEdit Timestamp="2025-07-03T13:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNION" b2="138 KV" b3="BUS3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNION" b2="138 KV" b3="C CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNION" b2="138 KV" b3="F CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100359</SeqNum>
    <Name>L138.Bureau-LTVSteel-Putnam (Ameren)</Name>
    <LastEdit Timestamp="2025-03-24T15:29:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BUREAU" b2="138 KV" b3="BUR-LTVS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUREAU" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUREAU" b2="138 KV" b3="H7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LTVSTEEL" b2="138 KV" b3="A3" />
      <ContingencyEquipment Action="L" Type="LN" b1="LTVSTEEL" b2="138 KV" b3="LTV-PUT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H43" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100360</SeqNum>
    <Name>L345.PleasantPrairie-MTP.2 (WEC)</Name>
    <LastEdit Timestamp="2025-03-18T16:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MTP" b2="345 KV" b3="9117" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTP" b2="345 KV" b3="9118" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTP" b2="345 KV" b3="MTP-PLE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEAS PR" b2="345 KV" b3="10-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLEAS PR" b2="345 KV" b3="2-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100361</SeqNum>
    <Name>L69.Howard-WShelby</Name>
    <LastEdit Timestamp="2025-03-24T11:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="69 KV" b3="O" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHELBY" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WSHELBY" b2="69 KV" b3="COPPERWE" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOWARD2" b2="69 KV" b3="HOW-WSHE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100362</SeqNum>
    <Name>230/36.Cumulus.TX2</Name>
    <LastEdit Timestamp="2025-03-24T11:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMULUS" b2="230 KV" b3="H252" />
      <ContingencyEquipment Action="X" Type="XF" b1="CUMULUS" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100363</SeqNum>
    <Name>500/13.CalvertCliffs.P-13000-3</Name>
    <LastEdit Timestamp="2025-04-18T17:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="14" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CALVERTC" b2="500 KV" b3="LD3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100365</SeqNum>
    <Name>230/26.Trenton.220-1TR</Name>
    <LastEdit Timestamp="2025-03-27T17:39:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="2-14" />
      <ContingencyEquipment Action="X" Type="XF" b1="TRENTON" b2="230 KV" b3="220-1TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="26 KV" b3="BUSTIEAB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="TRENTON" b2="26 KV" b3="CAP2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRENTON" b2="26 KV" b3="LOAD AB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100367</SeqNum>
    <Name>138/69/34.Dunlap.T2</Name>
    <LastEdit Timestamp="2025-03-28T15:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DUNLAP" b2="69 KV" b3="DUN-LUSH" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKHYDRO" b2="34 KV" b3="ELK-DUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNLAP" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNLAP" b2="34 KV" b3="L" />
      <ContingencyEquipment Action="X" Type="XF" b1="DUNLAP" b2="138 KV" b3="TR2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="DUNLAP" b2="69 KV" b3="TR2-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="DUNLAP" b2="34 KV" b3="TR2-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNLAP" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100368</SeqNum>
    <Name>L138.Sheffield-Marktown (NIPS)</Name>
    <LastEdit Timestamp="2026-02-10T16:54:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="17MRKTWN" b2="138 KV" b3="78N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17MRKTWN" b2="138 KV" b3="78S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="138 KV" b3="478" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="138 KV" b3="7778" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHEFFILD" b2="138 KV" b3="SHE-17M1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100369</SeqNum>
    <Name>L138.Chicago Ave - Inland5T(Mittal5).13829 (NIPS)</Name>
    <LastEdit Timestamp="2024-08-16T10:37:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHIC_AVE" b2="138 KV" b3="29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHIC_AVE" b2="138 KV" b3="29-33" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHIC_AVE" b2="138 KV" b3="CHI-INL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INLAND5T" b2="138 KV" b3="3829" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100370</SeqNum>
    <Name>L230.BullRun-Elklick.295 </Name>
    <LastEdit Timestamp="2025-06-26T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRUN" b2="230 KV" b3="200T295" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRUN" b2="230 KV" b3="29562" />
      <ContingencyEquipment Action="L" Type="LN" b1="BULLRUN" b2="230 KV" b3="295C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELKLCKDP" b2="230 KV" b3="29572-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELKLCKDP" b2="230 KV" b3="29572-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100371</SeqNum>
    <Name>L69.Sunbury-Point.1</Name>
    <LastEdit Timestamp="2025-05-13T09:30:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="POINT1" b2="69 KV" b3="POI-SUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="COLU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="COLU1PEN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100372</SeqNum>
    <Name>L69.Columbia-Point-Cherokee-Danville-GTI.2</Name>
    <LastEdit Timestamp="2025-12-30T15:23:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHEROKE1" b2="69 KV" b3="4046" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHEROKE1" b2="69 KV" b3="CHE-POI2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COLU PL" b2="69 KV" b3="SUN2INSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="69 KV" b3="SUNB2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHEROKE1" b2="69 KV" b3="CHE-DAN2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DANVILPL" b2="69 KV" b3="DAN-GTI2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DANVILPL" b2="69 KV" b3="DUM1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DANVILPL" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GTI" b2="69 KV" b3="4223" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GTI" b2="69 KV" b3="GTI_LD2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="POINT1" b2="69 KV" b3="4099" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLU PL" b2="69 KV" b3="COL-POI2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100374</SeqNum>
    <Name>L230.Gordonsville-Remington.2199</Name>
    <LastEdit Timestamp="2025-04-14T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONSV" b2="230 KV" b3="21352199" />
      <ContingencyEquipment Action="L" Type="LN" b1="GORDONSV" b2="230 KV" b3="GOR-REMI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONSV" b2="230 KV" b3="H3T2199" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGTN" b2="230 KV" b3="20772199" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGTN" b2="230 KV" b3="280T2199" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100375</SeqNum>
    <Name>L230.Cartanza-SilverRun.23032</Name>
    <LastEdit Timestamp="2025-04-14T11:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTANZA" b2="230 KV" b3="230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARTANZA" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARTANZA" b2="230 KV" b3="CAR-SIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERUN" b2="230 KV" b3="F220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERUN" b2="230 KV" b3="F230" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100376</SeqNum>
    <Name>L230.RedLion-SilverRun.23057</Name>
    <LastEdit Timestamp="2025-04-14T11:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="246" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="230 KV" b3="247" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDLION" b2="230 KV" b3="RED-SIL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERUN" b2="230 KV" b3="F210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERUN" b2="230 KV" b3="F220" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100377</SeqNum>
    <Name>L69.Frackville-PortCarbon-Fichbach.1</Name>
    <LastEdit Timestamp="2025-05-13T09:51:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FISHBACH" b2="69 KV" b3="FRAC1DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="ORWI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="SHE2ORW2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FISHBACH" b2="69 KV" b3="FIS-POR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRACKVIL" b2="69 KV" b3="FRA-POCA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PORTCRBN" b2="69 KV" b3="POCA2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100378</SeqNum>
    <Name>L230.CedarCreek-SilverRun.23030</Name>
    <LastEdit Timestamp="2025-04-08T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCRE" b2="230 KV" b3="230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCRE" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARCRE" b2="230 KV" b3="CED-SIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERUN" b2="230 KV" b3="F310" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERUN" b2="230 KV" b3="F320" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100379</SeqNum>
    <Name>L230.EastWindsor-Windsor.J2009</Name>
    <LastEdit Timestamp="2025-07-29T12:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="230 KV" b3="B46" />
      <ContingencyEquipment Action="L" Type="LN" b1="EWINDSOR" b2="230 KV" b3="EWI-WIN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EWINDSOR" b2="230 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND JC" b2="230 KV" b3="B38" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND JC" b2="230 KV" b3="B42" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100381</SeqNum>
    <Name>230/69.CedarGrove.220-1</Name>
    <LastEdit Timestamp="2025-03-26T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="X" Type="XF" b1="CEDARGRO" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="69 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="69 KV" b3="4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARGRO" b2="230 KV" b3="7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100382</SeqNum>
    <Name>DTX230.Metuchen.220-2</Name>
    <LastEdit Timestamp="2025-03-26T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="METUCHEN" b2="230 KV" b3="220-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100383</SeqNum>
    <Name>DTX230.Metuchen.220-4</Name>
    <LastEdit Timestamp="2025-03-26T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="2-4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="METUCHEN" b2="230 KV" b3="220-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="METUCHEN" b2="230 KV" b3="230SC3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100384</SeqNum>
    <Name>230/69.McCarter.220-7</Name>
    <LastEdit Timestamp="2025-03-26T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="69 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="230 KV" b3="2-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="MCCARTER" b2="230 KV" b3="220-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="69 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100385</SeqNum>
    <Name>230/26.McCarter.TR-1</Name>
    <LastEdit Timestamp="2025-06-02T12:51:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="230 KV" b3="1-5" />
      <ContingencyEquipment Action="X" Type="XF" b1="MCCARTER" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MCCARTER" b2="26 KV" b3="TR-1LO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100386</SeqNum>
    <Name>230/26.McCarter.TR-2</Name>
    <LastEdit Timestamp="2025-06-02T12:52:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="X" Type="XF" b1="MCCARTER" b2="230 KV" b3="220-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MCCARTER" b2="26 KV" b3="TR-2LO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100387</SeqNum>
    <Name>230/26.McCarter.TR-3</Name>
    <LastEdit Timestamp="2025-06-02T12:52:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="230 KV" b3="1-9" />
      <ContingencyEquipment Action="X" Type="XF" b1="MCCARTER" b2="230 KV" b3="220-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MCCARTER" b2="26 KV" b3="TR-3LO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100388</SeqNum>
    <Name>DTX230.Brunswick.T-10</Name>
    <LastEdit Timestamp="2025-03-26T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SECT 1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SECT 7-8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNSWIC" b2="230 KV" b3="T-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100389</SeqNum>
    <Name>DTX230.Brunswick.T20</Name>
    <LastEdit Timestamp="2025-03-26T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SECT2-10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRUNSWIC" b2="230 KV" b3="T20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100390</SeqNum>
    <Name>230/69.JacksonRoad.220-5T</Name>
    <LastEdit Timestamp="2025-03-27T17:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PS" b2="69 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PS" b2="69 KV" b3="1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PS" b2="230 KV" b3="11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK PS" b2="230 KV" b3="2-12" />
      <ContingencyEquipment Action="X" Type="XF" b1="JACK PS" b2="230 KV" b3="220-5T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100391</SeqNum>
    <Name>DTX230.Hillsdale.220-3</Name>
    <LastEdit Timestamp="2025-03-26T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILLSDAL" b2="230 KV" b3="220-3LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100392</SeqNum>
    <Name>DTX230.Hillsdale.220-4</Name>
    <LastEdit Timestamp="2025-03-26T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="15-16" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILLSDAL" b2="230 KV" b3="220-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="3-15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100393</SeqNum>
    <Name>230/69.GreenBrook.220-3</Name>
    <LastEdit Timestamp="2025-03-26T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENBRO" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENBRO" b2="69 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENBRO" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENBRO" b2="230 KV" b3="220-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENBRO" b2="69 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100394</SeqNum>
    <Name>DTX230.Hillsdale.T-1</Name>
    <LastEdit Timestamp="2025-03-26T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="3-13" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILLSDAL" b2="230 KV" b3="T-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100395</SeqNum>
    <Name>DTX230.Hillsdale.T-2</Name>
    <LastEdit Timestamp="2025-03-26T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="4-12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILLSDAL" b2="230 KV" b3="T-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100396</SeqNum>
    <Name>DTX230.Hillsdale.T-3</Name>
    <LastEdit Timestamp="2025-03-26T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILLSDAL" b2="230 KV" b3="T-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100397</SeqNum>
    <Name>DTX230.Hillsdale.T-4</Name>
    <LastEdit Timestamp="2025-03-26T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILLSDAL" b2="230 KV" b3="T-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100398</SeqNum>
    <Name>230/69.FrontStreet.220-2</Name>
    <LastEdit Timestamp="2025-03-26T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTST" b2="69 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTST" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="X" Type="XF" b1="FRONTST" b2="230 KV" b3="220-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTST" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRONTST" b2="69 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100402</SeqNum>
    <Name>L138.Desplains-4609-Howard.L4609</Name>
    <LastEdit Timestamp="2025-03-27T17:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="4609" b2="138 KV" b3="460-DES2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="198 DESP" b2="138 KV" b3="L4609 CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="4609" b2="138 KV" b3="460-HOWA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="215 HOWA" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="4609" b2="138 KV" b3="460-DESP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L4609 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100404</SeqNum>
    <Name>L345.Lisle-Lombard.10321</Name>
    <LastEdit Timestamp="2025-03-28T15:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="103 LISL" b2="345 KV" b3="10321" />
      <ContingencyEquipment Action="OP" Type="CB" b1="103 LISL" b2="345 KV" b3="L10321CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="120 LOMB" b2="345 KV" b3="L10321CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100405</SeqNum>
    <Name>L138.GrandRiver-PnsvlleMuni-Nursey-LeroyCenter.Q16</Name>
    <LastEdit Timestamp="2025-04-18T17:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDRVR" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDRVR" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANDRVR" b2="138 KV" b3="GRR-PAI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B77" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEROYCEN" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAINESV2" b2="138 KV" b3="LER-PAI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NURSERY" b2="138 KV" b3="Q2_T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NURSERY" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAINESV" b2="138 KV" b3="A1_Q16" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAINESV" b2="138 KV" b3="PAI-NUR2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PAINESV" b2="138 KV" b3="SW56" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="PAINESV2" b2="138 KV" b3="A6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAINESV2" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAINESV2" b2="138 KV" b3="PAI-NUR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100406</SeqNum>
    <Name>230/13.Parrish.3TR</Name>
    <LastEdit Timestamp="2025-04-02T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PARRISH" b2="13 KV" b3="3TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARRISH" b2="230 KV" b3="935 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PARRISH" b2="230 KV" b3="PAR 3TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100407</SeqNum>
    <Name>230/13.Parrish.2TR</Name>
    <LastEdit Timestamp="2025-04-07T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PARRISH" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARRISH" b2="230 KV" b3="825 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PARRISH" b2="230 KV" b3="PAR 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100408</SeqNum>
    <Name>230/13.Parrish.1TR</Name>
    <LastEdit Timestamp="2025-04-02T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PARRISH" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARRISH" b2="230 KV" b3="715 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PARRISH" b2="230 KV" b3="PAR 1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100409</SeqNum>
    <Name>L345.Leeds-Hurley</Name>
    <LastEdit Timestamp="2025-12-01T13:51:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="HURLEY" b2="345 KV" b3="2C-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HURLEY" b2="345 KV" b3="30151" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HURLEY" b2="345 KV" b3="30353" />
      <ContingencyEquipment Action="S" Type="SD" b1="HURLEY" b2="345 KV" b3="C-3" />
      <ContingencyEquipment Action="S" Type="SD" b1="HURLEY" b2="345 KV" b3="SD" />
      <ContingencyEquipment Action="L" Type="LN" b1="HURLEY" b2="345 KV" b3="HUR-LEE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEEDS" b2="345 KV" b3="R301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEEDS" b2="345 KV" b3="R94301" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100410</SeqNum>
    <Name>L345.TrimbleCounty-Middletown</Name>
    <LastEdit Timestamp="2025-04-02T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MIDLT_LG" b2="345 KV" b3="MID-TRMB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="345 KV" b3="MT_4541A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLT_LG" b2="345 KV" b3="MT_4541B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="4511_41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="TC_4541" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100411</SeqNum>
    <Name>L345.Marcy-CoopersCorner</Name>
    <LastEdit Timestamp="2025-04-02T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOPERSC" b2="345 KV" b3="4182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOPERSC" b2="345 KV" b3="42-4182" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOPERSC" b2="345 KV" b3="COO-MARC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARCY" b2="345 KV" b3="3202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARCY" b2="345 KV" b3="3208" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARCY" b2="345 KV" b3="MAR-MARC" />
      <ContingencyEquipment Action="S" Type="SD" b1="MARCYCOO" b2="345 KV" b3="SC 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100414</SeqNum>
    <Name>L345.Leeds-NewScotland.3</Name>
    <LastEdit Timestamp="2025-04-02T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LEEDS" b2="345 KV" b3="LEE-NEW3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEEDS" b2="345 KV" b3="R9293" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEEDS" b2="345 KV" b3="R93" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWSCOTL" b2="345 KV" b3="R93" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100418</SeqNum>
    <Name>500/345.Shawnee.094N (TVA)</Name>
    <LastEdit Timestamp="2025-04-02T15:21:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SHAWNEE4" b2="500 KV" b3="094N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEE4" b2="345 KV" b3="3034" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEE4" b2="345 KV" b3="3038" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEE4" b2="500 KV" b3="5054" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEE4" b2="500 KV" b3="5058" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100419</SeqNum>
    <Name>L500.Newport-Richmon</Name>
    <LastEdit Timestamp="2025-04-07T15:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPORT4" b2="500 KV" b3="12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPORT4" b2="500 KV" b3="22" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NEWPORT4" b2="500 KV" b3="RHMD" />
      <ContingencyEquipment Action="L" Type="LN" b1="RICHMON" b2="500 KV" b3="RICHMOND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHMON" b2="500 KV" b3="2NEW_BK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHMON" b2="500 KV" b3="2NEW_BK2" />
      <ContingencyEquipment Action="S" Type="SD" b1="RICHMON" b2="500 KV" b3="REAC_5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100420</SeqNum>
    <Name>500/230.Antioch.BK2</Name>
    <LastEdit Timestamp="2025-04-07T15:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ANTIOCH4" b2="500 KV" b3="21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANTIOCH4" b2="500 KV" b3="22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANTIOCH4" b2="230 KV" b3="42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANTIOCH4" b2="230 KV" b3="43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANTIOCH4" b2="230 KV" b3="51" />
      <ContingencyEquipment Action="X" Type="XF" b1="ANTIOCH4" b2="500 KV" b3="BK2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="ANTIOCH4" b2="230 KV" b3="BK2-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100421</SeqNum>
    <Name>500/230.PLGarden.AT5</Name>
    <LastEdit Timestamp="2025-04-07T15:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLGARDEN" b2="500 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLGARDEN" b2="500 KV" b3="11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLGARDEN" b2="230 KV" b3="31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLGARDEN" b2="230 KV" b3="41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLGARDEN" b2="500 KV" b3="5" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLGARDEN" b2="500 KV" b3="AT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100422</SeqNum>
    <Name>L345.Gibson-PoseyVilleEast (External)</Name>
    <LastEdit Timestamp="2026-04-28T13:39:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON2" b2="345 KV" b3="34542" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON2" b2="345 KV" b3="98G4" />
      <ContingencyEquipment Action="L" Type="LN" b1="GIBSON2" b2="345 KV" b3="GIB-POLY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POLYEAST" b2="345 KV" b3="3200" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POLYEAST" b2="345 KV" b3="3300" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100423</SeqNum>
    <Name>L161.AlcoaSW-AlcoaPRI-Calderwood.1</Name>
    <LastEdit Timestamp="2025-04-18T17:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALCOAPRI" b2="161 KV" b3="1530" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALCOAPRI" b2="161 KV" b3="1680" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCOA_SW" b2="161 KV" b3="ALC-ALC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALCOA_SW" b2="161 KV" b3="924" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCOAPRI" b2="161 KV" b3="ALC-CLDR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100424</SeqNum>
    <Name>L161.AlcoaSW-Fontana</Name>
    <LastEdit Timestamp="2025-04-07T15:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALCOA_SW" b2="161 KV" b3="984" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCOA_SW" b2="161 KV" b3="ALC-FONT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FONTANA" b2="161 KV" b3="938" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100425</SeqNum>
    <Name>L138.University-Mukwonago</Name>
    <LastEdit Timestamp="2025-08-11T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUKWGO73" b2="138 KV" b3="9319" />
      <ContingencyEquipment Action="L" Type="LN" b1="MUKWGO73" b2="138 KV" b3="MUK-UNIV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIVRST3" b2="138 KV" b3="UNIG52" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100426</SeqNum>
    <Name>L138.Paris-Raymond-StMartin</Name>
    <LastEdit Timestamp="2025-09-02T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PARIS 83" b2="138 KV" b3="9302" />
      <ContingencyEquipment Action="L" Type="LN" b1="PARIS 83" b2="138 KV" b3="PAR-RAYM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAYMOND" b2="138 KV" b3="G12-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RAYMOND" b2="138 KV" b3="T8_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STMART13" b2="138 KV" b3="9069" />
      <ContingencyEquipment Action="L" Type="LN" b1="RAYMOND" b2="138 KV" b3="RAY-STMA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100427</SeqNum>
    <Name>L345.Dresser-SugarCreek (CIN)</Name>
    <LastEdit Timestamp="2026-05-11T15:38:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08SCRK_M" b2="345 KV" b3="38-45" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08SCRK_M" b2="345 KV" b3="G1-38" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRESSER" b2="345 KV" b3="38 B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRESSER" b2="345 KV" b3="B3 38" />
      <ContingencyEquipment Action="L" Type="LN" b1="DRESSER" b2="345 KV" b3="DRE-SUGA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100428</SeqNum>
    <Name>L345.Callaway-Bland</Name>
    <LastEdit Timestamp="2025-04-07T15:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAND  3" b2="345 KV" b3="V21 TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLAND  3" b2="345 KV" b3="V23 TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CALAWY 3" b2="345 KV" b3="30154302" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALAWY 3" b2="345 KV" b3="V43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALAWY 3" b2="345 KV" b3="V45" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100429</SeqNum>
    <Name>345/161.Wilson.XF1 (BR)</Name>
    <LastEdit Timestamp="2025-04-07T15:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WILSONBR" b2="345 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONBR" b2="345 KV" b3="121" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONBR" b2="161 KV" b3="2001" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100430</SeqNum>
    <Name>L345.Labadie-WLWD-Mason4</Name>
    <LastEdit Timestamp="2025-08-22T08:23:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LABADIE3" b2="345 KV" b3="LAB-WLW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LABADIE3" b2="345 KV" b3="MASN L 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="MASON 13" b2="345 KV" b3="MAS-WLW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASON 13" b2="345 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLWD" b2="345 KV" b3="V3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100431</SeqNum>
    <Name>L345.Hazelton-HickoryCreek</Name>
    <LastEdit Timestamp="2025-04-07T15:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZLTON6" b2="345 KV" b3="9985" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZLTON6" b2="345 KV" b3="9986" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HCKRYCK" b2="345 KV" b3="5267" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HCKRYCK" b2="345 KV" b3="5268" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAZLTON6" b2="345 KV" b3="HAZ-HCK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100432</SeqNum>
    <Name>L115.Hathaway-Benson-CoolSprings.1032</Name>
    <LastEdit Timestamp="2025-05-22T13:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BENSONDP" b2="115 KV" b3="BEN-COOL" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENSONDP" b2="115 KV" b3="BEN-HATH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENSONDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPR" b2="115 KV" b3="103252" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPR" b2="115 KV" b3="80T1032" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="115 KV" b3="103202_3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATHAWAY" b2="115 KV" b3="103202_4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100433</SeqNum>
    <Name>L138.EastLake-Newell-Nash-GrandRiver.Q15</Name>
    <LastEdit Timestamp="2025-05-15T09:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="02NASH" b2="138 KV" b3="02N-GRR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02NASH" b2="138 KV" b3="02N-NEW1" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="02NASH" b2="138 KV" b3="SW323" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02NASH" b2="138 KV" b3="SWR330" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="B35" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTLAKE" b2="138 KV" b3="EAS-NEW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDRVR" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDRVR" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="NEWELL" b2="138 KV" b3="SW656" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWELL" b2="138 KV" b3="SWR532" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100434</SeqNum>
    <Name>L161.Cheoah-AlcoaPRI</Name>
    <LastEdit Timestamp="2025-04-07T15:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALCOAPRI" b2="161 KV" b3="1510" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALCOAPRI" b2="161 KV" b3="ALC-CHEO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEOAHH4" b2="161 KV" b3="10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100435</SeqNum>
    <Name>230/115.Remington.TX3</Name>
    <LastEdit Timestamp="2025-04-10T15:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGTN" b2="230 KV" b3="H342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGTN" b2="115 KV" b3="L342" />
      <ContingencyEquipment Action="X" Type="XF" b1="REMINGTN" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100436</SeqNum>
    <Name>L345.Montezuma-Ottumwa</Name>
    <LastEdit Timestamp="2025-04-10T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="OTTUMW16" b2="345 KV" b3="62455626" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MNTZUMA6" b2="345 KV" b3="DBM902" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MNTZUMA6" b2="345 KV" b3="DBM903" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTUMW16" b2="345 KV" b3="6118" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTUMW16" b2="345 KV" b3="6119" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100438</SeqNum>
    <Name>L345.SouthWestLima-Gristmill</Name>
    <LastEdit Timestamp="2025-11-06T14:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRISTMIL" b2="345 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRISTMIL" b2="345 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWLIMA" b2="345 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRISTMIL" b2="345 KV" b3="GRI-SWLM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100439</SeqNum>
    <Name>345/138.Gristmill.T1</Name>
    <LastEdit Timestamp="2025-04-18T17:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRISTMIL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRISTMIL" b2="345 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRISTMIL" b2="345 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="GEMINI" b2="138 KV" b3="GEM-GRST" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRISTMIL" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100440</SeqNum>
    <Name>L138.Gristmill-Gemini</Name>
    <LastEdit Timestamp="2025-04-18T17:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GEMINI" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEMINI" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRISTMIL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="GEMINI" b2="138 KV" b3="GEM-GRST" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRISTMIL" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100441</SeqNum>
    <Name>L138.Richland-Ridgeville-Stryker</Name>
    <LastEdit Timestamp="2025-11-03T14:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="RICHLND" b2="138 KV" b3="RIC-02R1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02RDGVL" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="138 KV" b3="B13245" />
      <ContingencyEquipment Action="L" Type="LN" b1="02RDGVL" b2="138 KV" b3="02R-STRY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRYKER" b2="138 KV" b3="B13222" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100442</SeqNum>
    <Name>L345.Wellsville-HibbetsMill + HibbetsMill.CC</Name>
    <LastEdit Timestamp="2025-04-10T15:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIBBMILL" b2="26 KV" b3="AUX1LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIBBMILL" b2="26 KV" b3="AUX2LOAD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HIBBMILL" b2="26 KV" b3="CTG-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIBBMILL" b2="345 KV" b3="CTG-1GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HIBBMILL" b2="26 KV" b3="CTG-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIBBMILL" b2="345 KV" b3="CTG-2GSU" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIBBMILL" b2="345 KV" b3="HIB-WELL" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HIBBMILL" b2="18 KV" b3="STG-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIBBMILL" b2="345 KV" b3="STG-1GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HIBBMILL" b2="18 KV" b3="STG-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIBBMILL" b2="345 KV" b3="STG-2GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLSVIL" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLSVIL" b2="345 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100443</SeqNum>
    <Name>L115.Skippers-Trego-Diamond-SmithPond-BrinkDP.1043</Name>
    <LastEdit Timestamp="2024-09-03T15:11:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRINKDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DIAMONDG" b2="115 KV" b3="DIA-SMTH" />
      <ContingencyEquipment Action="X" Type="XF" b1="DIAMONDG" b2="115 KV" b3="FTCRKGSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DIAMONDG" b2="34.5 KV" b3="FTCRKSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKIPPERS" b2="115 KV" b3="10371043" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKIPPERS" b2="115 KV" b3="130T1043" />
      <ContingencyEquipment Action="S" Type="SD" b1="SMTHPOND" b2="115 KV" b3="104382SD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRINKDP" b2="115 KV" b3="BRI-SMIT" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMTHPOND" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SMTHPOND" b2="34.5 KV" b3="PUMPKISP" />
      <ContingencyEquipment Action="L" Type="LN" b1="DIAMONDG" b2="115 KV" b3="DIA-TREG" />
      <ContingencyEquipment Action="L" Type="LN" b1="SKIPPERS" b2="115 KV" b3="SKI-TREG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TREGO" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100444</SeqNum>
    <Name>L115.Clubhouse-Metcalf-Emporia-IvoryLane.1029</Name>
    <LastEdit Timestamp="2026-04-20T13:16:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELFLDDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLBHOUSE" b2="115 KV" b3="102952" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLBHOUSE" b2="115 KV" b3="CLB-METC" />
      <ContingencyEquipment Action="L" Type="LN" b1="EMPORADP" b2="115 KV" b3="EMP-EMPO" />
      <ContingencyEquipment Action="L" Type="LN" b1="EMPORADP" b2="115 KV" b3="EMP-IVOL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EMPORADP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EMPORIA" b2="13 KV" b3="G12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EMPORIA" b2="13 KV" b3="LD1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="EMPORIA" b2="115 KV" b3="SC1" />
      <ContingencyEquipment Action="X" Type="XF" b1="EMPORIA" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="EMPORIA" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EMPORIA" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVORYLNE" b2="115 KV" b3="10291037" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVORYLNE" b2="115 KV" b3="102992" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELFLDDP" b2="115 KV" b3="BEL-METC" />
      <ContingencyEquipment Action="X" Type="XF" b1="METCALF" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="METCALF" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="METCALF" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="METCALF" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELFLDDP" b2="115 KV" b3="BEL-METT" />
      <ContingencyEquipment Action="L" Type="LN" b1="EMPORIA" b2="115 KV" b3="EMP-METC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100447</SeqNum>
    <Name>230/69.WestShore.TRAN3</Name>
    <LastEdit Timestamp="2026-03-31T15:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHORE" b2="230 KV" b3="TR3E_230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHORE" b2="69 KV" b3="TR3E_69" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHORE" b2="230 KV" b3="TR3W_230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHORE" b2="69 KV" b3="TR3W_69" />
      <ContingencyEquipment Action="X" Type="XF" b1="WSHORE" b2="230 KV" b3="TRAN3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100449</SeqNum>
    <Name>TEMP.L115.Perth-GritDP-OtterRiver-Altavista.31</Name>
    <LastEdit Timestamp="2025-05-27T17:51:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAVSTA" b2="115 KV" b3="3132" />
      <ContingencyEquipment Action="L" Type="LN" b1="OTTERRIV" b2="115 KV" b3="31B" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRITDP" b2="115 KV" b3="GRI-PERT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRITDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="OTTERRIV" b2="115 KV" b3="31A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTERRIV" b2="115 KV" b3="H162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTERRIV" b2="115 KV" b3="H262" />
      <ContingencyEquipment Action="X" Type="XF" b1="OTTERRIV" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OTTERRIV" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="OTTERRIV" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OTTERRIV" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERTH" b2="115 KV" b3="3142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERTH" b2="115 KV" b3="31T1022" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100451</SeqNum>
    <Name>L115.Westport-WilkensAve.110566</Name>
    <LastEdit Timestamp="2025-04-14T11:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="SW110566" />
      <ContingencyEquipment Action="X" Type="XF" b1="WILKENS" b2="115 KV" b3="110-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="WESTPORT" b2="115 KV" b3="WES-WIL2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100452</SeqNum>
    <Name>L115.Westport-WilkensAve.110565</Name>
    <LastEdit Timestamp="2025-04-11T17:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="10552TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTPORT" b2="115 KV" b3="1BUS" />
      <ContingencyEquipment Action="X" Type="XF" b1="WILKENS" b2="115 KV" b3="110-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WESTPORT" b2="115 KV" b3="WES-WIL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100454</SeqNum>
    <Name>115/13.Fitzell.110-4</Name>
    <LastEdit Timestamp="2025-04-14T11:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FITZELL" b2="115 KV" b3="110-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FITZELL" b2="13.8 KV" b3="13TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FITZELL" b2="115 KV" b3="981-503" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FITZELL" b2="115 KV" b3="982-503" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FITZELL" b2="13.8 KV" b3="LOAD4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100455</SeqNum>
    <Name>115/13.Fitzell.110-3</Name>
    <LastEdit Timestamp="2025-04-14T11:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FITZELL" b2="115 KV" b3="110-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FITZELL" b2="13.8 KV" b3="13TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FITZELL" b2="115 KV" b3="981-504" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FITZELL" b2="115 KV" b3="982-504" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FITZELL" b2="13.8 KV" b3="LOAD3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100457</SeqNum>
    <Name>138/69.Fremont.2-T</Name>
    <LastEdit Timestamp="2025-04-14T11:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FREMONT" b2="138 KV" b3="2-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONT" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREMONT" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100458</SeqNum>
    <Name>L115.IvoryLane-FntainDP-Skippers.1037</Name>
    <LastEdit Timestamp="2026-05-11T11:40:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FNTAINDP" b2="115 KV" b3="FNT-SKIP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FNTAINDP" b2="115 KV" b3="LD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVORYLNE" b2="115 KV" b3="10291037" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVORYLNE" b2="115 KV" b3="103792" />
      <ContingencyEquipment Action="L" Type="LN" b1="FNTAINDP" b2="115 KV" b3="FNT-IVOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKIPPERS" b2="115 KV" b3="10371043" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKIPPERS" b2="115 KV" b3="103712" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100459</SeqNum>
    <Name>L138.Auburn-Varner</Name>
    <LastEdit Timestamp="2025-05-12T13:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AUBURN" b2="138 KV" b3="AUB-VARN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AUBURN" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VARNRAEP" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VARNRAEP" b2="138 KV" b3="C1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100460</SeqNum>
    <Name>L138.PotterSS-NovaChemical.2</Name>
    <LastEdit Timestamp="2025-04-15T13:44:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NOVACHEM" b2="138 KV" b3="HI CB2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NOVACHEM" b2="13 KV" b3="LOAD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="NOVACHEM" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NOVACHEM" b2="138 KV" b3="NOV-POT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE7-6CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTERSS" b2="138 KV" b3="TIE7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100461</SeqNum>
    <Name>138/18.Eastlake.T500 &amp; SC.4.5 (CommonMode)</Name>
    <LastEdit Timestamp="2025-04-18T17:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="345 KV" b3="B712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="345 KV" b3="B725" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G4SC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q4T" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="24 KV" b3="SC5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100462</SeqNum>
    <Name>138/18.Eastlake.T399 &amp; SC.1.2.3.4 (CommonMode)</Name>
    <LastEdit Timestamp="2025-04-18T17:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G1SC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G2SC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G3SC" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EASTLAKE" b2="18 KV" b3="G4SC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q1T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q2T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q3T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTLAKE" b2="138 KV" b3="Q4T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100463</SeqNum>
    <Name>DTX230.NEWP PS.T-1</Name>
    <LastEdit Timestamp="2025-04-29T17:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWP PS" b2="230 KV" b3="1-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWP PS" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWP PS" b2="230 KV" b3="T-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100465</SeqNum>
    <Name>L138.H445-H440N</Name>
    <LastEdit Timestamp="2025-04-18T17:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="H440N" b2="138 KV" b3="H445" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H440N" b2="138 KV" b3="L2 210CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H445" b2="138 KV" b3="BT1-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H445" b2="138 KV" b3="BT1-4 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100466</SeqNum>
    <Name>138/69.NortheastCanton.T2</Name>
    <LastEdit Timestamp="2025-08-29T12:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NECANTON" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NECANTON" b2="138 KV" b3="J2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NECANTON" b2="69 KV" b3="K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NECANTON" b2="69 KV" b3="L2" />
      <ContingencyEquipment Action="X" Type="XF" b1="NECANTON" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100468</SeqNum>
    <Name>L138.Redeye-SmithMountain</Name>
    <LastEdit Timestamp="2026-03-18T16:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDEYE" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDEYE" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDEYE" b2="138 KV" b3="RED-SMIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100473</SeqNum>
    <Name>L345.Argenta-BattleCreek</Name>
    <LastEdit Timestamp="2026-02-27T15:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGENTA2" b2="345 KV" b3="28F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGENTA2" b2="345 KV" b3="28H9" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARGENTA2" b2="345 KV" b3="ARG-BAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATTLECR" b2="345 KV" b3="32H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATTLECR" b2="345 KV" b3="32R8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100474</SeqNum>
    <Name>L115.Erdman-MonumentStreet.110558</Name>
    <LastEdit Timestamp="2026-06-05T12:32:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ERDMAN" b2="115 KV" b3="ERD-MON8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERDMAN" b2="115 KV" b3="GBR6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ERDMAN" b2="115 KV" b3="GBT6" />
      <ContingencyEquipment Action="X" Type="XF" b1="MONUMEST" b2="115 KV" b3="110-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONUMEST" b2="115 KV" b3="110-1HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONUMEST" b2="115 KV" b3="563_558" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONUMEST" b2="115 KV" b3="FIVE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONUMEST" b2="13 KV" b3="ONE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100475</SeqNum>
    <Name>L115.Erdman-MonumentStreet.110557</Name>
    <LastEdit Timestamp="2025-04-18T17:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ERDMAN" b2="115 KV" b3="507-557" />
      <ContingencyEquipment Action="L" Type="LN" b1="ERDMAN" b2="115 KV" b3="ERD-MON7" />
      <ContingencyEquipment Action="X" Type="XF" b1="MONUMEST" b2="115 KV" b3="110-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONUMEST" b2="115 KV" b3="110-3HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONUMEST" b2="115 KV" b3="557_564" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONUMEST" b2="13 KV" b3="THREE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100477</SeqNum>
    <Name>345/138.Munster.A (NIPS)</Name>
    <LastEdit Timestamp="2025-04-24T14:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUNSTER2" b2="345 KV" b3="04_BKR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUNSTER2" b2="345 KV" b3="22_BKR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUNSTER2" b2="138 KV" b3="94-XFR1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MUNSTER2" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUNSTER2" b2="138 KV" b3="XFR1_BKR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100478</SeqNum>
    <Name>L138.Glencoe-Wbellai2</Name>
    <LastEdit Timestamp="2025-04-29T17:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GLENCOE" b2="138 KV" b3="GLE-WBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENCOE" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENCOE" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBELLAI2" b2="138 KV" b3="F2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100479</SeqNum>
    <Name>138/69.Glencoe.TR1</Name>
    <LastEdit Timestamp="2025-04-29T17:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENCOE" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENCOE" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENCOE" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENCOE" b2="69 KV" b3="L1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLENCOE" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100484</SeqNum>
    <Name>345/21.TrimbleCounty.T1</Name>
    <LastEdit Timestamp="2025-04-18T17:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRMBLPJM" b2="21 KV" b3="LOAD1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRMBLPJM" b2="21 KV" b3="TMBL11ME" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="1212_126" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRMBL_LG" b2="21 KV" b3="AUX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="21 KV" b3="TLG_AUX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="TRMBL_LG" b2="345 KV" b3="TRANS1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRMBL_LG" b2="21 KV" b3="TRIMBL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRMBL_LG" b2="21 KV" b3="TRM-TRM1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRMBL_LG" b2="21 KV" b3="TRMBL1EX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100485</SeqNum>
    <Name>345/24.TrimbleCounty.T2</Name>
    <LastEdit Timestamp="2025-04-18T17:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRMBLPJM" b2="24 KV" b3="LOAD2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRMBLPJM" b2="24 KV" b3="TMBL21ME" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="4512_42" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRMBL_LG" b2="24 KV" b3="LD_203" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRMBL_LG" b2="24 KV" b3="LD_204" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRMBL_LG" b2="345 KV" b3="TC_4512" />
      <ContingencyEquipment Action="X" Type="XF" b1="TRMBL_LG" b2="345 KV" b3="TRANS2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRMBL_LG" b2="24 KV" b3="TRIMBL2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRMBL_LG" b2="24 KV" b3="TRM-TRM2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TRMBL_LG" b2="24 KV" b3="TRMBL2EX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100486</SeqNum>
    <Name>SpanishGrove.SP</Name>
    <LastEdit Timestamp="2025-08-22T10:25:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPANGRO" b2="115 KV" b3="105092" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPANGRO" b2="115 KV" b3="105892" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPANGRO" b2="34.5 KV" b3="SPAGROSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPANGRO" b2="115 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPANGRO" b2="115 KV" b3="T1HS_CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPANGRO" b2="115 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPANGRO" b2="115 KV" b3="T2HS_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100487</SeqNum>
    <Name>TaylorsMill.SP</Name>
    <LastEdit Timestamp="2025-07-14T15:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TAYLRMIL" b2="69 KV" b3="104032" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAYLRMIL" b2="69 KV" b3="17332" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAYLRMIL" b2="69 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TAYLRMIL" b2="34.5 KV" b3="WHIHORSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100491</SeqNum>
    <Name>L345.Losantville-Headwaters.2</Name>
    <LastEdit Timestamp="2025-04-18T17:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOSANTVL" b2="34.5 KV" b3="52C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOSANTVL" b2="345 KV" b3="52U1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOSANTVL" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOSANTVL" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LOSANTVL" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LOSANTVL" b2="34.5 KV" b3="HEDWT2WF" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOSANTVL" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100492</SeqNum>
    <Name>DTX138.Medford.T2</Name>
    <LastEdit Timestamp="2025-04-29T17:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEDFORD" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEDFORD" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MEDFORD" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100493</SeqNum>
    <Name>L138.Desoto-Medford</Name>
    <LastEdit Timestamp="2025-04-29T17:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DESOTO" b2="138 KV" b3="DES-MED1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="F2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEDFORD" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEDFORD" b2="138 KV" b3="E2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100495</SeqNum>
    <Name>L138.Kentonku-Sardinia</Name>
    <LastEdit Timestamp="2025-04-29T17:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTN_LG" b2="138 KV" b3="B091_734" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENTN_LG" b2="138 KV" b3="B091_737" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SARDINIA" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENTN_LG" b2="138 KV" b3="KEN-SARD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100496</SeqNum>
    <Name>138/69.Olive.T3</Name>
    <LastEdit Timestamp="2025-10-24T12:50:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="OLIVE" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="138 KV" b3="K2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OLIVE" b2="69 KV" b3="NWCRNIPS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100498</SeqNum>
    <Name>L345.GunnRoad.SCIOTORIDGE.WF</Name>
    <LastEdit Timestamp="2026-04-08T09:58:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GUNNROAD" b2="345 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUNNROAD" b2="345 KV" b3="M2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUNNROAD" b2="34.5 KV" b3="SCIOT1WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUNNROAD" b2="34.5 KV" b3="SCIOT2WF" />
      <ContingencyEquipment Action="S" Type="SD" b1="GUNNROAD" b2="345 KV" b3="SCIOTORD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUNNROAD" b2="345 KV" b3="SRIDGE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100500</SeqNum>
    <Name>TMI.500.Cap2</Name>
    <LastEdit Timestamp="2025-05-08T12:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TMI" b2="500 KV" b3="B30" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="TMI" b2="500 KV" b3="CAP 2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100501</SeqNum>
    <Name>L230.HomerCity-Shelocta</Name>
    <LastEdit Timestamp="2026-02-02T12:15:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="230 KV" b3="208" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="230 KV" b3="209" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOMERCIT" b2="230 KV" b3="HOM-SHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELOCTA" b2="230 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELOCTA" b2="230 KV" b3="B40" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100502</SeqNum>
    <Name>L138.Delaware-Royerton</Name>
    <LastEdit Timestamp="2025-08-21T12:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELAWAIM" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROYERTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROYERTON" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELAWAIM" b2="138 KV" b3="DEL-ROYE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100503</SeqNum>
    <Name>L138.Royerton-Desoto</Name>
    <LastEdit Timestamp="2025-10-07T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DESOTO" b2="138 KV" b3="DES-ROY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROYERTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROYERTON" b2="138 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100504</SeqNum>
    <Name>138/69.Royerton.T2</Name>
    <LastEdit Timestamp="2025-04-22T13:47:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROYERTON" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROYERTON" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROYERTON" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROYERTON" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100507</SeqNum>
    <Name>L138.KenzieCreek-BlossomTrail</Name>
    <LastEdit Timestamp="2025-04-21T15:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLOSSOMT" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLOSSOMT" b2="138 KV" b3="BLO-KENZ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLOSSOMT" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="138 KV" b3="G2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100508</SeqNum>
    <Name>Mackeys.SP</Name>
    <LastEdit Timestamp="2025-06-27T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MACKEYS" b2="230 KV" b3="212642" />
      <ContingencyEquipment Action="X" Type="XF" b1="MACKEYS" b2="230 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MACKEYS" b2="34.5 KV" b3="MACKEYSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACKEYS" b2="230 KV" b3="T232" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100509</SeqNum>
    <Name>CoolSprings.SP.MOCCASSP</Name>
    <LastEdit Timestamp="2025-04-21T15:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="COOLSPR" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPR" b2="115 KV" b3="GSU_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOLSPR" b2="34.5 KV" b3="MOCCASCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COOLSPR" b2="34.5 KV" b3="MOCCASSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100510</SeqNum>
    <Name>L138.GosneyHill-NauvooRidge</Name>
    <LastEdit Timestamp="2025-04-21T15:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOSNEYHI" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOSNEYHI" b2="138 KV" b3="GOS-NAUV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAUVOORI" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAUVOORI" b2="138 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100511</SeqNum>
    <Name>L138.NorthEastCanton-Packard-WestCanton</Name>
    <LastEdit Timestamp="2025-04-21T15:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NECANTON" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NECANTON" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NECANTON" b2="138 KV" b3="NEC-PAC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PACKARD2" b2="138 KV" b3="T1 LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="PACKARD2" b2="138 KV" b3="PAC-WCA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100512</SeqNum>
    <Name>HardinSS.SP</Name>
    <LastEdit Timestamp="2026-03-26T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HARDIN" b2="34.5 KV" b3="HRDN12SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HARDIN" b2="34.5 KV" b3="HRDN23SP" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARDIN" b2="345 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARDIN" b2="345 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100517</SeqNum>
    <Name>L138.Jay-BitterRidge</Name>
    <LastEdit Timestamp="2026-03-26T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BITTERRI" b2="138 KV" b3="52-T1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BITTERRI" b2="34.5 KV" b3="BITERRWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="BITTERRI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BITTERRI" b2="138 KV" b3="BIT-JAY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JAY" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JAY" b2="138 KV" b3="C_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100518</SeqNum>
    <Name>230/35.Hayfield.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAYFIEL4" b2="230 KV" b3="H244M" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HAYFIEL4" b2="230 KV" b3="SC9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYFIEL4" b2="230 KV" b3="SC942" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAYFIEL4" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAYFIEL4" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100524</SeqNum>
    <Name>230/35.Hayfield.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-04-22T11:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAYFIEL4" b2="230 KV" b3="H144M" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAYFIEL4" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAYFIEL4" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100526</SeqNum>
    <Name>230/35.Braddock.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-04-22T11:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRADDOCK" b2="230 KV" b3="H174M" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRADDOCK" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRADDOCK" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100528</SeqNum>
    <Name>230/35.Braddock.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-04-22T11:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BRADDOCK" b2="230 KV" b3="H274M" />
      <ContingencyEquipment Action="X" Type="XF" b1="BRADDOCK" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRADDOCK" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100530</SeqNum>
    <Name>230/115.Locks.TX6</Name>
    <LastEdit Timestamp="2024-11-08T09:52:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKS" b2="230 KV" b3="H6T205" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKS" b2="115 KV" b3="L622" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOCKS" b2="230 KV" b3="TX6_" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100532</SeqNum>
    <Name>230/35.Plaza.TX5 </Name>
    <LastEdit Timestamp="2026-05-01T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLAZA" b2="230 KV" b3="H522" />
      <ContingencyEquipment Action="X" Type="XF" b1="PLAZA" b2="230 KV" b3="TX5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PLAZA" b2="35 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100534</SeqNum>
    <Name>230/115.ReevesAvenue.TX4 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="REEVESAV" b2="230 KV" b3="H414M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="115 KV" b3="L412" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="REEVESAV" b2="230 KV" b3="SC4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="230 KV" b3="SC412" />
      <ContingencyEquipment Action="X" Type="XF" b1="REEVESAV" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100536</SeqNum>
    <Name>230/115.ReevesAvenue.TX5 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-04-22T11:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="REEVESAV" b2="230 KV" b3="H514M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEVESAV" b2="115 KV" b3="L512" />
      <ContingencyEquipment Action="X" Type="XF" b1="REEVESAV" b2="230 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100542</SeqNum>
    <Name>Desper.SP</Name>
    <LastEdit Timestamp="2026-05-11T11:34:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DESPER" b2="230 KV" b3="220232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESPER" b2="230 KV" b3="230432" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DESPER" b2="34.5 KV" b3="DESPERSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="DESPER" b2="230 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100543</SeqNum>
    <Name>L138.Lockwood-Shicksville-Sowers</Name>
    <LastEdit Timestamp="2025-04-25T16:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKWOOD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOCKWOOD" b2="138 KV" b3="LOC-SHI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHICKSVI" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHICKSVI" b2="138 KV" b3="SHI-SOWR" />
      <ContingencyEquipment Action="X" Type="XF" b1="SHICKSVI" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOWERS" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOWERS" b2="138 KV" b3="K2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100544</SeqNum>
    <Name>L138.Holloway-DillesBottom</Name>
    <LastEdit Timestamp="2025-04-25T16:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DILLESBO" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DILLESBO" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="DILLESBO" b2="138 KV" b3="DIL-HOLL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="G3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="G4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100545</SeqNum>
    <Name>DTX138.DillesBottom.T1</Name>
    <LastEdit Timestamp="2025-04-25T16:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DILLESBO" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DILLESBO" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DILLESBO" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100546</SeqNum>
    <Name>L138.Holloway-GeorgeWashington</Name>
    <LastEdit Timestamp="2025-04-25T16:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="138 KV" b3="S2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GEORGEWA" b2="138 KV" b3="GEO-HOLL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLLOWAY" b2="138 KV" b3="H4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100547</SeqNum>
    <Name>DTX138.Royerton.T1 </Name>
    <LastEdit Timestamp="2025-05-02T12:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROYERTON" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROYERTON" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROYERTON" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100548</SeqNum>
    <Name>138/69.Bosserman.T1</Name>
    <LastEdit Timestamp="2025-05-02T12:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOSSERMN" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="X" Type="XF" b1="BOSSERMN" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100550</SeqNum>
    <Name>DryBread.SP</Name>
    <LastEdit Timestamp="2025-04-30T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DRYBREAD" b2="230 KV" b3="220182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRYBREAD" b2="230 KV" b3="25482" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DRYBREAD" b2="34.5 KV" b3="DRYBRDSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="DRYBREAD" b2="230 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100551</SeqNum>
    <Name>L230.Lakeview-DryBread.254A</Name>
    <LastEdit Timestamp="2026-05-01T11:33:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DRYBREAD" b2="230 KV" b3="25482" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRYBREAD" b2="230 KV" b3="254T2201" />
      <ContingencyEquipment Action="L" Type="LN" b1="DRYBREAD" b2="230 KV" b3="DRY-LAKE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEVIE4" b2="230 KV" b3="213T254" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEVIE4" b2="230 KV" b3="25462" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100552</SeqNum>
    <Name>L230.ClubHouse-DryBread.2201A</Name>
    <LastEdit Timestamp="2025-04-30T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLBHOUSE" b2="230 KV" b3="238T2201" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRYBREAD" b2="230 KV" b3="220182" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRYBREAD" b2="230 KV" b3="254T2201" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLBHOUSE" b2="230 KV" b3="CLU-DRYB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100553</SeqNum>
    <Name>IvoryLane.SP</Name>
    <LastEdit Timestamp="2025-04-30T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IVORYLNE" b2="115 KV" b3="102992" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IVORYLNE" b2="115 KV" b3="103792" />
      <ContingencyEquipment Action="X" Type="XF" b1="IVORYLNE" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="IVORYLNE" b2="34.5 KV" b3="IVORLNSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100554</SeqNum>
    <Name>DTX138.Gemini.LOAD1</Name>
    <LastEdit Timestamp="2025-04-29T17:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GEMINI" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEMINI" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GEMINI" b2="138 KV" b3="CAPAA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GEMINI" b2="138 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100555</SeqNum>
    <Name>DTX138.Gemini.LOAD2</Name>
    <LastEdit Timestamp="2025-04-29T17:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GEMINI" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEMINI" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GEMINI" b2="138 KV" b3="CAPBB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GEMINI" b2="138 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100556</SeqNum>
    <Name>L230.Loudoun-CatharDP-Youngsbr</Name>
    <LastEdit Timestamp="2025-12-24T10:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CATHARDP" b2="230 KV" b3="CAT-YOUN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CATHARDP" b2="230 KV" b3="DP1LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="20942140" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUDOUN4" b2="230 KV" b3="214052" />
      <ContingencyEquipment Action="L" Type="LN" b1="CATHARDP" b2="230 KV" b3="CAT-LOUD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YOUNGSBR" b2="230 KV" b3="214042" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YOUNGSBR" b2="230 KV" b3="ZT2140" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100557</SeqNum>
    <Name>L138.ValleyIM-Almena</Name>
    <LastEdit Timestamp="2025-12-16T12:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALMENA" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALMENA" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALMENA" b2="138 KV" b3="XT4" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALMENA" b2="138 KV" b3="ALM-VAL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VALLEYIM" b2="138 KV" b3="K" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100558</SeqNum>
    <Name>138/69.Almena.T4</Name>
    <LastEdit Timestamp="2025-05-15T09:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALMENA" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALMENA" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALMENA" b2="138 KV" b3="XT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100559</SeqNum>
    <Name>L500.Hatfield-GreeneCounty + GreenCounty.CC</Name>
    <LastEdit Timestamp="2026-02-10T12:58:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENECC" b2="23 KV" b3="52G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENECC" b2="23 KV" b3="AUX_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENECC" b2="500 KV" b3="B1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GREENECC" b2="23 KV" b3="GREENECC" />
      <ContingencyEquipment Action="X" Type="XF" b1="GREENECC" b2="500 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATFIELD" b2="500 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HATFIELD" b2="500 KV" b3="B12" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENECC" b2="500 KV" b3="GRE-HATF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100560</SeqNum>
    <Name>L138.Macksburg-Buell</Name>
    <LastEdit Timestamp="2025-04-25T17:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUELL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARENDSRI" b2="138 KV" b3="ARE-BUEL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUELL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACKSBRG" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUELL" b2="138 KV" b3="BUE-MACK" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MACKSBRG" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MACKSBRG" b2="138 KV" b3="MAC-SOL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100563</SeqNum>
    <Name>L138.Brunswick-Stoney (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-01T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWOE" b2="138 KV" b3="B201" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWOE" b2="138 KV" b3="B204" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BRUNSWOE" b2="138 KV" b3="C11" />
      <ContingencyEquipment Action="L" Type="LN" b1="STONEY" b2="138 KV" b3="STO-BRU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANGROE" b2="138 KV" b3="B52" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GRANGROE" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STONEY" b2="138 KV" b3="A 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100565</SeqNum>
    <Name>L138.WAkron-Granger-Stoney (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-01T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="BRUNSWOE" b2="138 KV" b3="C11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWOE" b2="138 KV" b3="CS1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GRANGROE" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRANGROE" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STONEY" b2="138 KV" b3="A 59" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANGROE" b2="138 KV" b3="GRA-STO1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WAKRON" b2="138 KV" b3="A275" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKRON" b2="138 KV" b3="B273" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAKRON" b2="138 KV" b3="WAK-GRA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100567</SeqNum>
    <Name>L138.NilesCentral-Garden (Sctnlz)</Name>
    <LastEdit Timestamp="2025-05-16T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CNTRALOE" b2="138 KV" b3="37" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CNTRALOE" b2="138 KV" b3="A 23" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARDENOE" b2="138 KV" b3="GAR-CNT1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GARDENOE" b2="138 KV" b3="CS3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100568</SeqNum>
    <Name>L138.Packard-Elm-Garden (Sctnlz)</Name>
    <LastEdit Timestamp="2025-05-16T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02CORTLD" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMOHED" b2="138 KV" b3="ELM-02C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMOHED" b2="138 KV" b3="ELM-PAC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELMOHED" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GARDENOE" b2="138 KV" b3="A 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMOHED" b2="138 KV" b3="ELM-GAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PACKRDOE" b2="138 KV" b3="13" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PACKRDOE" b2="138 KV" b3="A 8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100570</SeqNum>
    <Name>L138.BayShore-Oregon (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-11T15:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="02OREGON" b2="138 KV" b3="CS13410" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYSHOR2" b2="138 KV" b3="B13255" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYSHOR2" b2="138 KV" b3="BAY-02O1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100571</SeqNum>
    <Name>L138.Maclean-Oregon (Sctnlz)</Name>
    <LastEdit Timestamp="2025-05-16T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="02OREGON" b2="138 KV" b3="CS13411" />
      <ContingencyEquipment Action="L" Type="LN" b1="02OREGON" b2="138 KV" b3="MAC-ORE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACLEAN" b2="138 KV" b3="B13201" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100573</SeqNum>
    <Name>L138.AllenJct-SilReyTap-Reynolds (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-28T12:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02SILICA" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02SILICA" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENJUN" b2="138 KV" b3="ALL-SILR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENJUN" b2="138 KV" b3="B13377" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="REYNSILI" b2="138 KV" b3="CS13385" />
      <ContingencyEquipment Action="L" Type="LN" b1="02SILICA" b2="138 KV" b3="02S-SILR" />
      <ContingencyEquipment Action="L" Type="LN" b1="REYNSILI" b2="138 KV" b3="REY-SILR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100574</SeqNum>
    <Name>L138.Vulcan-UnivToledo-Reynolds (Sctnlz)</Name>
    <LastEdit Timestamp="2025-05-22T13:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="UNIV_TOL" b2="138 KV" b3="02U-REY1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="REYNSILI" b2="138 KV" b3="CS13388" />
      <ContingencyEquipment Action="L" Type="LN" b1="UNIV_TOL" b2="138 KV" b3="02U-VUL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIV_TOL" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VULCAN" b2="138 KV" b3="B13397" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100577</SeqNum>
    <Name>500/138.Yukon.TR5</Name>
    <LastEdit Timestamp="2025-08-25T11:28:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="500 KV" b3="B104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="500 KV" b3="B185" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="X" Type="XF" b1="YUKON" b2="500 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100580</SeqNum>
    <Name>HillcrestSP</Name>
    <LastEdit Timestamp="2025-04-29T17:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILCRST2" b2="138 KV" b3="52-T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILCRST2" b2="34.5 KV" b3="HLCRS1CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HILCRST2" b2="34.5 KV" b3="HLCRS1SP" />
      <ContingencyEquipment Action="X" Type="XF" b1="HILCRST2" b2="138 KV" b3="T1-GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100581</SeqNum>
    <Name>L138.Mullens-Pierpont-Tamsmount</Name>
    <LastEdit Timestamp="2025-04-29T17:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MULLENS" b2="138 KV" b3="MUL-PIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MULLENS" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PIERPON2" b2="138 KV" b3="MABEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAMSMOUN" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAMSMOUN" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="L" Type="LN" b1="PIERPON2" b2="138 KV" b3="PIE-TAM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100582</SeqNum>
    <Name>L138.Tamsmount-Stotesburg-Pemberton</Name>
    <LastEdit Timestamp="2025-04-29T17:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEMBERT2" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="L" Type="LN" b1="PEMBERT2" b2="138 KV" b3="PEM-STO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STOTESBU" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAMSMOUN" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAMSMOUN" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="STOTESBU" b2="138 KV" b3="STO-TAM1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100583</SeqNum>
    <Name>DTX138.Tamsmount.T2</Name>
    <LastEdit Timestamp="2025-04-30T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TAMSMOUN" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAMSMOUN" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TAMSMOUN" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100584</SeqNum>
    <Name>L138.Delaware-Lantern-Fuson</Name>
    <LastEdit Timestamp="2025-04-29T17:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELAWAIM" b2="138 KV" b3="W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FUSON" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FUSON" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FUSON" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELAWAIM" b2="138 KV" b3="DEL-LAN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FUSON" b2="138 KV" b3="FUS-LANT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LANTERNP" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANTERNP" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100586</SeqNum>
    <Name>L138.Devola-ArendsRidgeSw-Buell</Name>
    <LastEdit Timestamp="2025-04-29T17:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARENDSRI" b2="138 KV" b3="ARE-BUEL" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARENDSRI" b2="138 KV" b3="ARE-DVLA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ARENDSRI" b2="138 KV" b3="LOWELL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUELL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEVOLA" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEVOLA" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100587</SeqNum>
    <Name>138/69.Reusens.T4 </Name>
    <LastEdit Timestamp="2025-05-09T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="REUSENS" b2="138 KV" b3=".  4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REUSENS" b2="138 KV" b3="AF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REUSENS" b2="69 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100588</SeqNum>
    <Name>138/69.Reusens.T1</Name>
    <LastEdit Timestamp="2025-05-09T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="REUSENS" b2="34 KV" b3=".  3" />
      <ContingencyEquipment Action="X" Type="XF" b1="REUSENS" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REUSENS" b2="138 KV" b3="AD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REUSENS" b2="34 KV" b3="GLAMORGA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REUSENS" b2="34 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REUSENS" b2="34 KV" b3="O" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100589</SeqNum>
    <Name>L138.Gemini-WestMoulton</Name>
    <LastEdit Timestamp="2025-04-29T17:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GEMINI" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEMINI" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GEMINI" b2="138 KV" b3="GEM-WMOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMOULTON" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMOULTON" b2="138 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100590</SeqNum>
    <Name>L138.Sowers-Varner</Name>
    <LastEdit Timestamp="2025-05-28T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SOWERS" b2="138 KV" b3="AA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SOWERS" b2="138 KV" b3="CAPAA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOWERS" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOWERS" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="SOWERS" b2="138 KV" b3="SOW-VARN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VARNRAEP" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VARNRAEP" b2="138 KV" b3="C1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100591</SeqNum>
    <Name>L115.Northeast-WindyEdge.110592</Name>
    <LastEdit Timestamp="2025-04-30T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="592-2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="592-3B" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHEAS" b2="115 KV" b3="NOR-WIN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110592" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100593</SeqNum>
    <Name>L138.Aero-Oakbrook</Name>
    <LastEdit Timestamp="2025-09-23T14:18:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AERO1" b2="138 KV" b3="AER-OAKB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AERO1" b2="138 KV" b3="CB956" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AERO1" b2="138 KV" b3="CB968" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKBROOK" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKBROOK" b2="138 KV" b3="BK3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKBROOK" b2="69 KV" b3="CB641" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKBROOK" b2="138 KV" b3="CB816" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100594</SeqNum>
    <Name>DTX138.Aero.L1</Name>
    <LastEdit Timestamp="2025-04-30T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AERO1" b2="138 KV" b3="CB962" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AERO1" b2="138 KV" b3="CB964" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AERO1" b2="138 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100595</SeqNum>
    <Name>DTX138.Aero.L2</Name>
    <LastEdit Timestamp="2025-04-30T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AERO1" b2="138 KV" b3="CB960" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AERO1" b2="138 KV" b3="CB962" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AERO1" b2="138 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100596</SeqNum>
    <Name>DTX138.Aero.L3</Name>
    <LastEdit Timestamp="2025-04-30T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AERO1" b2="138 KV" b3="CB966" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AERO1" b2="138 KV" b3="CB968" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AERO1" b2="138 KV" b3="LOAD3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100597</SeqNum>
    <Name>DTX138.Aero.L4</Name>
    <LastEdit Timestamp="2025-04-30T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AERO1" b2="138 KV" b3="CB956" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AERO1" b2="138 KV" b3="CB960" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AERO1" b2="138 KV" b3="LOAD4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100598</SeqNum>
    <Name>L138.Donaldson-Woodspoint</Name>
    <LastEdit Timestamp="2025-04-30T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DONALDSN" b2="138 KV" b3="978" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DONALDSN" b2="138 KV" b3="983" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DONALDSN" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSPNT" b2="138 KV" b3="CB821" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSPNT" b2="138 KV" b3="CB824" />
      <ContingencyEquipment Action="L" Type="LN" b1="DONALDSN" b2="138 KV" b3="DON-WOOD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100599</SeqNum>
    <Name>L138.Buffington-Florence-Woodspoint</Name>
    <LastEdit Timestamp="2025-04-30T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFINGT" b2="138 KV" b3="945" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLORNCE" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLORNCE" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLORNCE" b2="138 KV" b3="BK4" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUFFINGT" b2="138 KV" b3="BUF-08F1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSPNT" b2="138 KV" b3="CB821" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSPNT" b2="138 KV" b3="CB826" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLORNCE" b2="138 KV" b3="FLO-WOOD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100600</SeqNum>
    <Name>L230.Buttermilk-Cumulus.2203</Name>
    <LastEdit Timestamp="2025-05-08T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTTRMLK" b2="230 KV" b3="21522203" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTTRMLK" b2="230 KV" b3="220312" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUTTRMLK" b2="230 KV" b3="BUT-CUMU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMULUS" b2="230 KV" b3="H12T2203" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMULUS" b2="230 KV" b3="H34T2203" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100602</SeqNum>
    <Name>DTX230.Buttermilk.TX2</Name>
    <LastEdit Timestamp="2025-08-22T10:29:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTTRMLK" b2="230 KV" b3="220312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTTRMLK" b2="230 KV" b3="221412" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUTTRMLK" b2="36.5 KV" b3="LD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUTTRMLK" b2="230 KV" b3="TX_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100603</SeqNum>
    <Name>DTX230.Buttermilk.TX3</Name>
    <LastEdit Timestamp="2025-08-22T10:29:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTTRMLK" b2="230 KV" b3="215212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTTRMLK" b2="230 KV" b3="217012" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUTTRMLK" b2="36.5 KV" b3="LD3" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUTTRMLK" b2="230 KV" b3="TX_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100604</SeqNum>
    <Name>L230.Buttermilk-Pacific.2170</Name>
    <LastEdit Timestamp="2025-12-03T11:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTTRMLK" b2="230 KV" b3="217012" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTTRMLK" b2="230 KV" b3="21702214" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUTTRMLK" b2="230 KV" b3="BUT-PACI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PACIFIC" b2="230 KV" b3="21702231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PACIFIC" b2="230 KV" b3="217032" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100605</SeqNum>
    <Name>L230.Buttermilk-Roundtable.2214</Name>
    <LastEdit Timestamp="2025-07-07T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTTRMLK" b2="230 KV" b3="21702214" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTTRMLK" b2="230 KV" b3="221412" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUTTRMLK" b2="230 KV" b3="BUT-ROUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTBL" b2="230 KV" b3="21492214" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTBL" b2="230 KV" b3="221402" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100606</SeqNum>
    <Name>L230.Trenton-Yardville-WardAve.L-2343</Name>
    <LastEdit Timestamp="2025-07-17T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="2-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARDAV" b2="230 KV" b3="L-Y" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YARDVILL" b2="230 KV" b3="T-1CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRENTON" b2="230 KV" b3="TRE-YARL" />
      <ContingencyEquipment Action="L" Type="LN" b1="WARDAV" b2="230 KV" b3="WAR-YARL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100608</SeqNum>
    <Name>Hartsmill.SP</Name>
    <LastEdit Timestamp="2025-04-30T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HARTSMIL" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HARTSMIL" b2="34.5 KV" b3="HARTSMSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARTSMIL" b2="115 KV" b3="W64_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100610</SeqNum>
    <Name>L230.SouthAnna-Desper.2202 + SouthAnna.G2</Name>
    <LastEdit Timestamp="2026-05-11T11:34:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DESPER" b2="230 KV" b3="22022304" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESPER" b2="230 KV" b3="220232" />
      <ContingencyEquipment Action="L" Type="LN" b1="DESPER" b2="230 KV" b3="DES-SANN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANNA" b2="230 KV" b3="20742202" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SANNA" b2="230 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANNA" b2="230 KV" b3="G2T2202" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100611</SeqNum>
    <Name>138/69.Kiamensi.AT1</Name>
    <LastEdit Timestamp="2025-04-30T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="X" Type="XF" b1="KIAMENSI" b2="138 KV" b3="AT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100612</SeqNum>
    <Name>L138.Riverport-Holston</Name>
    <LastEdit Timestamp="2025-04-30T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HOLSTON" b2="138 KV" b3="HOL-RIVR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLSTON" b2="138 KV" b3="V" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERPRT" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERPRT" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100616</SeqNum>
    <Name>L69.HardingsCorner-Closter.47</Name>
    <LastEdit Timestamp="2025-04-30T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOSTER" b2="69 KV" b3="3-28-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOSTER" b2="69 KV" b3="4-28-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOSTER" b2="69 KV" b3="CLO-HARI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARINGSC" b2="69 KV" b3="230-A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARINGSC" b2="69 KV" b3="BK230 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100617</SeqNum>
    <Name>L69.Cresskill-Closter.61</Name>
    <LastEdit Timestamp="2025-10-10T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOSTER" b2="69 KV" b3="1-28-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOSTER" b2="69 KV" b3="4-28-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOSTER" b2="69 KV" b3="CLO-CRE6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESSKIL" b2="69 KV" b3="61-37" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100619</SeqNum>
    <Name>L69.Closter-Sparkill.751 Tie</Name>
    <LastEdit Timestamp="2025-04-30T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOSTER" b2="69 KV" b3="751282" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOSTER" b2="69 KV" b3="CLO-SPAR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SPARKILL" b2="69 KV" b3="751-50-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100623</SeqNum>
    <Name>DTX138.Riverport.AIRPD1</Name>
    <LastEdit Timestamp="2025-05-02T12:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERPRT" b2="138 KV" b3="AIRPD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERPRT" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERPRT" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100624</SeqNum>
    <Name>DTX138.Riverport.AIRPD2</Name>
    <LastEdit Timestamp="2025-05-02T12:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERPRT" b2="138 KV" b3="AIRPD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERPRT" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERPRT" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100625</SeqNum>
    <Name>Redeye.BEDFRFSP</Name>
    <LastEdit Timestamp="2025-05-02T13:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDEYE" b2="138 KV" b3="52-T1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDEYE" b2="34.5 KV" b3="BEDFRFSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDEYE" b2="138 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100626</SeqNum>
    <Name>L345.McLean-Bloom.91309 + BloomingGrove.WF</Name>
    <LastEdit Timestamp="2025-05-02T13:03:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="913 BLOO" b2="35 KV" b3="BLOOM2WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="913 BLOO" b2="35 KV" b3="BLOOMGWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="913 BLOO" b2="345 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="913 BLOO" b2="345 KV" b3="T1CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="913 BLOO" b2="345 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="913 BLOO" b2="345 KV" b3="T2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="92 MCLEA" b2="345 KV" b3="1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="92 MCLEA" b2="345 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="913 BLOO" b2="345 KV" b3="91309" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100627</SeqNum>
    <Name>L138.Devola-MillCreek</Name>
    <LastEdit Timestamp="2024-05-14T09:50:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEVOLA" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEVOLA" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEVOLA" b2="138 KV" b3="DEV-MILL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL AEP" b2="138 KV" b3="T138" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILL AEP" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100628</SeqNum>
    <Name>DTX115.Edinboro.2TX</Name>
    <LastEdit Timestamp="2026-01-20T17:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EDINBORO" b2="115 KV" b3="2TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDINBORO" b2="115 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDINBORO" b2="115 KV" b3="B27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDINBORO" b2="34.5 KV" b3="B2TX" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDINBORO" b2="115 KV" b3="EDI-VEN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100629</SeqNum>
    <Name>L115.Northeast-MiddleRiver.110583</Name>
    <LastEdit Timestamp="2025-08-22T10:37:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="MIDDLERI" b2="115 KV" b3="5TR_02" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MIDDLERI" b2="115 KV" b3="5TR_83" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MIDDLERI" b2="115 KV" b3="6TR_83" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MIDDLERI" b2="115 KV" b3="8TR_83" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MIDDLERI" b2="115 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="583B_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="583F_18" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDDLERI" b2="115 KV" b3="MID-NOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100630</SeqNum>
    <Name>DTX138.Gore.T2</Name>
    <LastEdit Timestamp="2025-05-02T12:58:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GORE APS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORE APS" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GORE APS" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100631</SeqNum>
    <Name>DTX138.Gore.T1</Name>
    <LastEdit Timestamp="2025-07-10T19:05:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GORE APS" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORE APS" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GORE APS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100633</SeqNum>
    <Name>L115.Northeast-WindyEdge.110591</Name>
    <LastEdit Timestamp="2025-05-15T09:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="110591" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="582-591" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINDYEDG" b2="115 KV" b3="110591" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTHEAS" b2="115 KV" b3="NOR-WIN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100635</SeqNum>
    <Name>DTX138.WolfGlade.T1</Name>
    <LastEdit Timestamp="2025-05-15T09:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFGLAD" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFGLAD" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOLFGLAD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100636</SeqNum>
    <Name>DTX138.WolfGlade.T2 </Name>
    <LastEdit Timestamp="2025-05-15T09:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFGLAD" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFGLAD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOLFGLAD" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100637</SeqNum>
    <Name>L138.Universal-Plum.Z-154 </Name>
    <LastEdit Timestamp="2025-08-25T15:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PLUM" b2="138 KV" b3="PLU-UNI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLUM" b2="138 KV" b3="UNIV154" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIVERSA" b2="138 KV" b3="PLUM154" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100638</SeqNum>
    <Name>DTX138.WaldoRun.SHERWD2</Name>
    <LastEdit Timestamp="2025-05-05T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="B112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="B113" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALDORUN" b2="138 KV" b3="SHERWD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100639</SeqNum>
    <Name>L230.Trenton-Yardville-WardAve.L2347</Name>
    <LastEdit Timestamp="2025-10-10T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARDAV" b2="230 KV" b3="P-H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YARDVILL" b2="230 KV" b3="T-2CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRENTON" b2="230 KV" b3="TRE-YARP" />
      <ContingencyEquipment Action="L" Type="LN" b1="WARDAV" b2="230 KV" b3="WAR-YARP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100644</SeqNum>
    <Name>L230.Gainesville-Heathcote.2176</Name>
    <LastEdit Timestamp="2025-08-29T13:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAINESVL" b2="230 KV" b3="217692-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAINESVL" b2="230 KV" b3="217692-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="GAINESVL" b2="230 KV" b3="GAI-HEAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATHCOT" b2="230 KV" b3="217602" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATHCOT" b2="230 KV" b3="21762185" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100645</SeqNum>
    <Name>230/138.WardAve.220-1</Name>
    <LastEdit Timestamp="2026-02-10T13:14:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WARDAV" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WARDAV" b2="230 KV" b3="220-1XF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WARDAV" b2="138 KV" b3="COLONILD" />
      <ContingencyEquipment Action="S" Type="SD" b1="WARDAV" b2="138 KV" b3="E-1383SR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100649</SeqNum>
    <Name>345/138.BedfordPark.TR81</Name>
    <LastEdit Timestamp="2025-05-06T11:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="345 KV" b3="1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="115 BEDF" b2="138 KV" b3="TR81 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="115 BEDF" b2="345 KV" b3="TR81CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="115 BEDF" b2="138 KV" b3="TR81CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100651</SeqNum>
    <Name>L345.Nucor-Whitestown (CIN)</Name>
    <LastEdit Timestamp="2025-05-05T11:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NUCOR" b2="345 KV" b3="26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NUCOR" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NUCOR" b2="345 KV" b3="NUC-WHI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITESTO" b2="345 KV" b3="24-26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITESTO" b2="345 KV" b3="26-B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100654</SeqNum>
    <Name>DTX138.BasinRoad.T2</Name>
    <LastEdit Timestamp="2025-05-09T10:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BASINRD" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100655</SeqNum>
    <Name>DTX138.BearDPL.TR1</Name>
    <LastEdit Timestamp="2020-11-16T13:24:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAR DPL" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAR DPL" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAR DPL" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="BEAR DPL" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100656</SeqNum>
    <Name>DTX138.BearDPL.TR2</Name>
    <LastEdit Timestamp="2020-11-16T13:24:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAR DPL" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAR DPL" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAR DPL" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="BEAR DPL" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100657</SeqNum>
    <Name>DTX138.BearDPL.TR3</Name>
    <LastEdit Timestamp="2025-05-08T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAR DPL" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAR DPL" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAR DPL" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100658</SeqNum>
    <Name>DTX69.Bozman.MBLTPL</Name>
    <LastEdit Timestamp="2020-11-16T13:26:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOZMAN" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOZMAN" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOZMAN" b2="69 KV" b3="MBLTPL" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="BOZMAN" b2="69 KV" b3="MBLTPL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100659</SeqNum>
    <Name>DTX69.Bozman.Load</Name>
    <LastEdit Timestamp="2020-11-16T13:26:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOZMAN" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOZMAN" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOZMAN" b2="69 KV" b3="LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="BOZMAN" b2="69 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100660</SeqNum>
    <Name>DTX138.BrandyWine.T5</Name>
    <LastEdit Timestamp="2024-05-31T14:36:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDYWN" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDYWN" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRANDYWN" b2="138 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100661</SeqNum>
    <Name>DTX138.BrandyWine.T4</Name>
    <LastEdit Timestamp="2026-02-10T08:39:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDYWN" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDYWN" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRANDYWN" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100662</SeqNum>
    <Name>DTX69.Cambridge.T3</Name>
    <LastEdit Timestamp="2020-11-16T13:26:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIDG" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIDG" b2="69 KV" b3="7170" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAMBRIDG" b2="69 KV" b3="LOADT3" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="CAMBRIDG" b2="69 KV" b3="LOADT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100663</SeqNum>
    <Name>DTX69.Cambridge.T4</Name>
    <LastEdit Timestamp="2020-11-16T13:25:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIDG" b2="69 KV" b3="7140" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIDG" b2="69 KV" b3="7150" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAMBRIDG" b2="69 KV" b3="LOADT4" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="CAMBRIDG" b2="69 KV" b3="LOADT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100664</SeqNum>
    <Name>DTX138.Carville.T1</Name>
    <LastEdit Timestamp="2025-05-09T10:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARVILLE" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARVILLE" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARVILLE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100665</SeqNum>
    <Name>DTX138.Carville.T2</Name>
    <LastEdit Timestamp="2025-05-08T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARVILLE" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARVILLE" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARVILLE" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100666</SeqNum>
    <Name>DTX69.CedarNeck.T1</Name>
    <LastEdit Timestamp="2020-11-16T13:24:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARNEC" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARNEC" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CEDARNEC" b2="69 KV" b3="T1 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="CEDARNEC" b2="69 KV" b3="T1 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100667</SeqNum>
    <Name>DTX69.CedarNeck.T2</Name>
    <LastEdit Timestamp="2020-11-16T13:24:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARNEC" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARNEC" b2="69 KV" b3="65" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CEDARNEC" b2="69 KV" b3="T2 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="CEDARNEC" b2="69 KV" b3="T2 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100668</SeqNum>
    <Name>DTX138.ChapelStreet.T2</Name>
    <LastEdit Timestamp="2025-05-08T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAPELST" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAPELST" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHAPELST" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100669</SeqNum>
    <Name>DTX138.ChapelStreet.T3</Name>
    <LastEdit Timestamp="2025-05-08T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAPELST" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAPELST" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHAPELST" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100670</SeqNum>
    <Name>DTX69.Church.T3</Name>
    <LastEdit Timestamp="2025-05-08T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="7250" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHURCH" b2="69 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100671</SeqNum>
    <Name>DTX69.Church.T4</Name>
    <LastEdit Timestamp="2025-05-08T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="7220" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHURCH" b2="69 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100672</SeqNum>
    <Name>DTX138.Clayton.T2</Name>
    <LastEdit Timestamp="2024-05-31T14:47:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTON" b2="138 KV" b3="8260" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTON" b2="138 KV" b3="8270" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLAYTON" b2="138 KV" b3="LOADT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100673</SeqNum>
    <Name>DTX138.Edgemoor.T6 (LX)</Name>
    <LastEdit Timestamp="2024-05-31T14:52:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="3-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="138 KV" b3="3-7" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDGEMOOR" b2="138 KV" b3="T6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100674</SeqNum>
    <Name>DTX230.Crest.T1</Name>
    <LastEdit Timestamp="2020-11-16T13:23:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CREST" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CREST" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CREST" b2="230 KV" b3="T1 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="CREST" b2="230 KV" b3="T1 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100675</SeqNum>
    <Name>DTX230.Crest.T2</Name>
    <LastEdit Timestamp="2020-11-16T13:23:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CREST" b2="230 KV" b3="233" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CREST" b2="230 KV" b3="234" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CREST" b2="230 KV" b3="T2 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="CREST" b2="230 KV" b3="T2 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100676</SeqNum>
    <Name>DTX138.Clayton.T1</Name>
    <LastEdit Timestamp="2024-05-31T14:47:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTON" b2="138 KV" b3="8280" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYTON" b2="138 KV" b3="8290" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLAYTON" b2="138 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100677</SeqNum>
    <Name>DTX69.FruitLand.T1</Name>
    <LastEdit Timestamp="2020-11-16T13:22:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRUITLAN" b2="69 KV" b3="7540" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRUITLAN" b2="69 KV" b3="7550" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRUITLAN" b2="69 KV" b3="FRT-PEM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRUITLAN" b2="69 KV" b3="LOADT1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="FRUITLAN" b2="69 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100678</SeqNum>
    <Name>DTX69.FruitLand.T2</Name>
    <LastEdit Timestamp="2020-11-16T13:22:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRUITLAN" b2="69 KV" b3="7500" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRUITLAN" b2="69 KV" b3="7540" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRUITLAN" b2="69 KV" b3="FRT-LOR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRUITLAN" b2="69 KV" b3="LOADT2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="FRUITLAN" b2="69 KV" b3="LOADT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100679</SeqNum>
    <Name>DTX138.Harmony.T1</Name>
    <LastEdit Timestamp="2024-05-31T14:53:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="137" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="138" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HARMONY" b2="138 KV" b3="BROOKSFC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARMONY" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100680</SeqNum>
    <Name>DTX138.Harmony.T2</Name>
    <LastEdit Timestamp="2024-05-31T14:54:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="137" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARMONY" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100681</SeqNum>
    <Name>DTX138.Harmony.T3</Name>
    <LastEdit Timestamp="2024-05-31T14:54:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="140" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="141" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARMONY" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100682</SeqNum>
    <Name>DTX138.Harmony.T4</Name>
    <LastEdit Timestamp="2024-05-31T14:54:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="139" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="140" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARMONY" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100683</SeqNum>
    <Name>DTX138.Kiamensi.T2</Name>
    <LastEdit Timestamp="2024-05-31T14:59:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="138" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="139" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KIAMENSI" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100684</SeqNum>
    <Name>DTX138.Kiamensi.T3</Name>
    <LastEdit Timestamp="2024-05-31T15:00:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KIAMENSI" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100685</SeqNum>
    <Name>DTX138.KingsCreek.T1</Name>
    <LastEdit Timestamp="2025-05-08T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSCRK" b2="138 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100686</SeqNum>
    <Name>DTX138.KingsCreek.T2</Name>
    <LastEdit Timestamp="2025-05-08T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KINGSCRK" b2="138 KV" b3="138" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSCRK" b2="138 KV" b3="LOADT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100692</SeqNum>
    <Name>L138.ChicagoAve-Praixair3</Name>
    <LastEdit Timestamp="2024-08-16T10:37:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHIC_AVE" b2="138 KV" b3="31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHIC_AVE" b2="138 KV" b3="31-00" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHIC_AVE" b2="138 KV" b3="CHI-PRA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRAXAIR3" b2="138 KV" b3="3831" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100693</SeqNum>
    <Name>L115.Cloud-Kerrdam</Name>
    <LastEdit Timestamp="2026-03-24T08:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="115 KV" b3="3822-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="115 KV" b3="3822-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="65" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOUD" b2="115 KV" b3="CLO-KERR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100694</SeqNum>
    <Name>138/69.Derby.T2</Name>
    <LastEdit Timestamp="2026-03-26T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DERBY" b2="138 KV" b3="2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="DERBY" b2="69 KV" b3="2-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="DERBY" b2="34 KV" b3="2-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DERBY" b2="69 KV" b3="J2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DERBY" b2="34 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DERBY" b2="69 KV" b3="N2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DERBY" b2="34 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DERBY" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100695</SeqNum>
    <Name>L138.Derby-MainStreet</Name>
    <LastEdit Timestamp="2025-02-21T14:56:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DERBY" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="DERBY" b2="138 KV" b3="DER-MAI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINSTRE" b2="138 KV" b3="AC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100696</SeqNum>
    <Name>L138.MillCreek-SpringCreek-Eldean</Name>
    <LastEdit Timestamp="2025-05-16T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="09SPRING" b2="138 KV" b3="09S-ELD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09SPRING" b2="138 KV" b3="BK-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09SPRING" b2="138 KV" b3="HALTERMN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDEAN1" b2="138 KV" b3="OR-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDEAN1" b2="138 KV" b3="OR-F" />
      <ContingencyEquipment Action="L" Type="LN" b1="09SPRING" b2="138 KV" b3="09S-MIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILCREEK" b2="138 KV" b3="BU-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILCREEK" b2="138 KV" b3="BU-E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100697</SeqNum>
    <Name>DTX138.MillCreek.BK2</Name>
    <LastEdit Timestamp="2025-05-09T10:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILCREEK" b2="138 KV" b3="BU-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILCREEK" b2="138 KV" b3="BU-F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100698</SeqNum>
    <Name>DTX138.MillCreek.BK3</Name>
    <LastEdit Timestamp="2025-05-09T10:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILCREEK" b2="138 KV" b3="BU-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILCREEK" b2="138 KV" b3="BU-D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100704</SeqNum>
    <Name>L345.Ruby-Kansas</Name>
    <LastEdit Timestamp="2025-05-13T09:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KANSAS 3" b2="345 KV" b3="V31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANSAS 3" b2="345 KV" b3="V33" />
      <ContingencyEquipment Action="L" Type="LN" b1="KANSAS 3" b2="345 KV" b3="KAN-RUBY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUBY" b2="345 KV" b3="V5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUBY" b2="345 KV" b3="V7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100705</SeqNum>
    <Name>DTX138.MtPleasant.T1</Name>
    <LastEdit Timestamp="2020-12-13T18:16:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MTPLEASN" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTPLEASN" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTPLEASN" b2="138 KV" b3="T1LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MTPLEASN" b2="138 KV" b3="T1LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100706</SeqNum>
    <Name>DTX138.MtPleasant.T2</Name>
    <LastEdit Timestamp="2020-12-13T18:15:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MTPLEASN" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTPLEASN" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTPLEASN" b2="138 KV" b3="T2LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MTPLEASN" b2="138 KV" b3="T2LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100707</SeqNum>
    <Name>DTX138.Reybold.T1</Name>
    <LastEdit Timestamp="2020-12-13T18:15:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 135" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REYBOLD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="REYBOLD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100708</SeqNum>
    <Name>DTX138.Reybold.T2</Name>
    <LastEdit Timestamp="2020-12-13T18:15:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYBOLD" b2="138 KV" b3="PCB 133" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REYBOLD" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="REYBOLD" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100709</SeqNum>
    <Name>DTX138.SilverBrook.T2</Name>
    <LastEdit Timestamp="2020-12-13T18:15:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERBR" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERBR" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="L" Type="LN" b1="SILVERBR" b2="138 KV" b3="SIL-WWI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SILVERBR" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SILVERBR" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100710</SeqNum>
    <Name>DTX138.SilverBrook.T3</Name>
    <LastEdit Timestamp="2020-12-13T18:15:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERBR" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERBR" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="L" Type="LN" b1="KIAMENSI" b2="138 KV" b3="KIA-SIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SILVERBR" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SILVERBR" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100711</SeqNum>
    <Name>DTX138.SunsetLake.T1</Name>
    <LastEdit Timestamp="2020-12-13T18:15:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNSETLA" b2="138 KV" b3="130 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNSETLA" b2="138 KV" b3="134 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNSETLA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SUNSETLA" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100712</SeqNum>
    <Name>DTX138.SunsetLake.T3</Name>
    <LastEdit Timestamp="2020-12-13T18:15:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNSETLA" b2="138 KV" b3="133 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNSETLA" b2="138 KV" b3="134 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNSETLA" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SUNSETLA" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100713</SeqNum>
    <Name>DTX138.SunsetLake.T2</Name>
    <LastEdit Timestamp="2025-05-13T09:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNSETLA" b2="138 KV" b3="131 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNSETLA" b2="138 KV" b3="132 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNSETLA" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100714</SeqNum>
    <Name>DTX69.Sussex.T1</Name>
    <LastEdit Timestamp="2020-12-13T18:15:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSSEX" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSSEX" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSSEX" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SUSSEX" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUSSEX" b2="69 KV" b3="LOADT1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SUSSEX" b2="69 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100715</SeqNum>
    <Name>DTX69.FivePoints.T1</Name>
    <LastEdit Timestamp="2020-12-13T18:14:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FIVEPTS" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIVEPTS" b2="69 KV" b3="65" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIVEPTS" b2="69 KV" b3="FIV-LAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FIVEPTS" b2="69 KV" b3="LOADT1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="FIVEPTS" b2="69 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100716</SeqNum>
    <Name>DTX69.FivePoints.T2</Name>
    <LastEdit Timestamp="2020-12-13T18:14:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FIVEPTS" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIVEPTS" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIVEPTS" b2="69 KV" b3="FIV-LEW" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FIVEPTS" b2="69 KV" b3="LOADT2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="FIVEPTS" b2="69 KV" b3="LOADT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100717</SeqNum>
    <Name>DTX69.Worcester.T1</Name>
    <LastEdit Timestamp="2020-12-13T18:14:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="69 KV" b3="7240" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="69 KV" b3="7280" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="69 KV" b3="GEN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WORCESTE" b2="69 KV" b3="LOADT1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="WORCESTE" b2="69 KV" b3="LOADT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WORCESTE" b2="69 KV" b3="WORSOSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100718</SeqNum>
    <Name>DTX69.Worcester.T2</Name>
    <LastEdit Timestamp="2020-12-13T18:14:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="69 KV" b3="7230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="69 KV" b3="7240" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WORCESTE" b2="69 KV" b3="GEN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WORCESTE" b2="69 KV" b3="LOADT2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="WORCESTE" b2="69 KV" b3="LOADT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WORCESTE" b2="69 KV" b3="WORNOSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100719</SeqNum>
    <Name>DTX69.WyeMills.T2</Name>
    <LastEdit Timestamp="2020-12-13T18:14:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="7560" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="7570" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WYEMILLS" b2="69 KV" b3="LOADT2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="WYEMILLS" b2="69 KV" b3="LOADT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100720</SeqNum>
    <Name>DTX69.WyeMills.T3</Name>
    <LastEdit Timestamp="2020-12-13T18:14:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WYEMILLS" b2="69 KV" b3="LOADT3" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="WYEMILLS" b2="69 KV" b3="LOADT3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="69 KV" b3="WYE" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WYEMILLS" b2="69 KV" b3="WYEMILSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100721</SeqNum>
    <Name>DTX138.WestWilmington.T1</Name>
    <LastEdit Timestamp="2020-12-13T18:14:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WWILMING" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWILMING" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WWILMING" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="WWILMING" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100722</SeqNum>
    <Name>DTX138.WestWilmington.T2</Name>
    <LastEdit Timestamp="2020-12-13T18:14:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WWILMING" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWILMING" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WWILMING" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="WWILMING" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100723</SeqNum>
    <Name>DTX69.EastNewMarket.E-NMKT</Name>
    <LastEdit Timestamp="2025-08-11T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENEWMARK" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENEWMARK" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENEWMARK" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ENEWMARK" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ENEWMARK" b2="69 KV" b3="CAP2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ENEWMARK" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100724</SeqNum>
    <Name>DTX138.Glasgow.T2</Name>
    <LastEdit Timestamp="2025-05-13T09:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLASGOW" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLASGOW" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLASGOW" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100725</SeqNum>
    <Name>DTX138.Glasgow.T4</Name>
    <LastEdit Timestamp="2025-05-13T09:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLASGOW" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLASGOW" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLASGOW" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100726</SeqNum>
    <Name>DTX69.WestDPL.T2</Name>
    <LastEdit Timestamp="2020-12-13T18:13:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="69 KV" b3="63 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="69 KV" b3="68 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTDPL" b2="69 KV" b3="LOAD2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="WESTDPL" b2="69 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100727</SeqNum>
    <Name>DTX69.WestDPL.T5</Name>
    <LastEdit Timestamp="2020-12-13T18:13:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="69 KV" b3="64 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="69 KV" b3="66 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTDPL" b2="69 KV" b3="LOAD5" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="WESTDPL" b2="69 KV" b3="LOAD5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100728</SeqNum>
    <Name>DTX138.Bishop.T1</Name>
    <LastEdit Timestamp="2025-05-13T09:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP" b2="138 KV" b3="165" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP" b2="138 KV" b3="166" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BISHOP" b2="138 KV" b3="T1 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100729</SeqNum>
    <Name>DTX138.Cheswold.T3</Name>
    <LastEdit Timestamp="2025-05-13T09:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWOLD" b2="138 KV" b3="8230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWOLD" b2="138 KV" b3="8240" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHESWOLD" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100730</SeqNum>
    <Name>DTX138.CedarCreek.T1</Name>
    <LastEdit Timestamp="2025-05-13T09:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCRE" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCRE" b2="138 KV" b3="137" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CEDARCRE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100731</SeqNum>
    <Name>DTX138.FarmView.Load1</Name>
    <LastEdit Timestamp="2026-02-10T08:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVIEW" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVIEW" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FARMVIEW" b2="138 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100732</SeqNum>
    <Name>DTX138.Keeney.T2LD</Name>
    <LastEdit Timestamp="2025-05-13T09:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEENEY" b2="138 KV" b3="T2_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100733</SeqNum>
    <Name>DTX230.Keeney.T2</Name>
    <LastEdit Timestamp="2025-05-13T09:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="235" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="238" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="230 KV" b3="241" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEENEY" b2="230 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100734</SeqNum>
    <Name>DTX138.Pocomoke.Load1</Name>
    <LastEdit Timestamp="2020-12-13T18:12:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POCOMOKE" b2="138 KV" b3="131 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCOMOKE" b2="138 KV" b3="132 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="COSTEN" b2="138 KV" b3="COS-POC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POCOMOKE" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="POCOMOKE" b2="138 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100735</SeqNum>
    <Name>DTX138.Pocomoke.Load2</Name>
    <LastEdit Timestamp="2020-12-13T18:12:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POCOMOKE" b2="138 KV" b3="130 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCOMOKE" b2="138 KV" b3="131 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POCOMOKE" b2="138 KV" b3="LOAD2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="POCOMOKE" b2="138 KV" b3="LOAD2" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKHALL" b2="138 KV" b3="OAK-POC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100736</SeqNum>
    <Name>DTX138.LumsPond.T1</Name>
    <LastEdit Timestamp="2024-05-31T15:01:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMSPOND" b2="138 KV" b3="PCB 131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMSPOND" b2="138 KV" b3="PCB 132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LUMSPOND" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100737</SeqNum>
    <Name>DTX138.LumsPond.T2</Name>
    <LastEdit Timestamp="2024-05-31T15:02:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMSPOND" b2="138 KV" b3="PCB 132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMSPOND" b2="138 KV" b3="PCB 133" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LUMSPOND" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100738</SeqNum>
    <Name>DTX138.RedLion.T1</Name>
    <LastEdit Timestamp="2025-12-18T17:21:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REDLION" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100739</SeqNum>
    <Name>DTX69.RehoBoth.REHT1</Name>
    <LastEdit Timestamp="2020-12-13T18:11:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REHOBOTH" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REHOBOTH" b2="69 KV" b3="90" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REHOBOTH" b2="69 KV" b3="REHT1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="REHOBOTH" b2="69 KV" b3="REHT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100740</SeqNum>
    <Name>DTX69.RehoBoth.REHT2</Name>
    <LastEdit Timestamp="2020-12-13T18:11:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REHOBOTH" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REHOBOTH" b2="69 KV" b3="80" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REHOBOTH" b2="69 KV" b3="REHT2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="REHOBOTH" b2="69 KV" b3="REHT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100741</SeqNum>
    <Name>DTX138.138thStreet.LoadT1</Name>
    <LastEdit Timestamp="2020-12-13T18:11:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ST138" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ST138" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHANY" b2="138 KV" b3="BET-ST1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ST138" b2="138 KV" b3="LOADT1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="ST138" b2="138 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100742</SeqNum>
    <Name>DTX138.138thStreet.LoadT2+13thStreet.SVC</Name>
    <LastEdit Timestamp="2024-05-31T14:41:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ST138" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ST138" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ST138" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ST138" b2="138 KV" b3="LOADT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ST138" b2="138 KV" b3="SVC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100743</SeqNum>
    <Name>DTX69.WattsVille.LoadT1</Name>
    <LastEdit Timestamp="2025-05-15T09:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="69 KV" b3="7650" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATTSVIL" b2="69 KV" b3="7660" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WATTSVIL" b2="69 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100744</SeqNum>
    <Name>230/35.Windsor.5TR</Name>
    <LastEdit Timestamp="2026-02-10T11:26:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND JC" b2="230 KV" b3="B42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND JC" b2="230 KV" b3="B46" />
      <ContingencyEquipment Action="X" Type="XF" b1="WIND JC" b2="230 KV" b3="BK 5TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND JC" b2="34.5 KV" b3="BK5LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100746</SeqNum>
    <Name>138/34.64Bellwood.TR78</Name>
    <LastEdit Timestamp="2025-12-05T12:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="138 KV" b3="138TR78" />
      <ContingencyEquipment Action="X" Type="XF" b1="64 BELLW" b2="138 KV" b3="TR78 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="64 BELLW" b2="34.5 KV" b3="TR78 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100747</SeqNum>
    <Name>SouthAnna.G1</Name>
    <LastEdit Timestamp="2025-05-15T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SANNA" b2="230 KV" b3="52G1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANNA" b2="230 KV" b3="52G1B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SANNA" b2="230 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANNA" b2="230 KV" b3="G1T2074" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100748</SeqNum>
    <Name>SouthAnna.G2</Name>
    <LastEdit Timestamp="2025-05-15T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SANNA" b2="230 KV" b3="52G2A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANNA" b2="230 KV" b3="52G2B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SANNA" b2="230 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANNA" b2="230 KV" b3="G2T2202" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100749</SeqNum>
    <Name>L138.Gaston-MississinewaLake-DeerCreek</Name>
    <LastEdit Timestamp="2025-05-15T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCREE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEERCREE" b2="138 KV" b3="DEE-MIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="GASTON" b2="138 KV" b3="GAS-MIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GASTON" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GASTON" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MISSISSI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MISSISSI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MISSISSI" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100751</SeqNum>
    <Name>DTX138.BethelPark.T62</Name>
    <LastEdit Timestamp="2025-10-14T11:34:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHELPA" b2="138 KV" b3="2-3TIECB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHELPA" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHELPA" b2="138 KV" b3="T62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100752</SeqNum>
    <Name>DTX138.BethelPark.T61</Name>
    <LastEdit Timestamp="2025-10-14T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHELPA" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHELPA" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHELPA" b2="138 KV" b3="WILSONCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100753</SeqNum>
    <Name>DTX138.BethelPark.T63</Name>
    <LastEdit Timestamp="2025-09-18T09:56:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHELPA" b2="138 KV" b3="2-3TIECB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHELPA" b2="138 KV" b3="ST CLAIR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHELPA" b2="138 KV" b3="T63" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100754</SeqNum>
    <Name>DTX138.Bredinville.T2</Name>
    <LastEdit Timestamp="2025-09-18T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BREDINVI" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BREDINVI" b2="138 KV" b3="CABREJCT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BREDINVI" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100755</SeqNum>
    <Name>DTX138.Bredinville.T1</Name>
    <LastEdit Timestamp="2025-09-18T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BREDINVI" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BREDINVI" b2="138 KV" b3="KILGO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BREDINVI" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100756</SeqNum>
    <Name>DTX138.Brookhaven.T3</Name>
    <LastEdit Timestamp="2025-09-18T09:56:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKHAV" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROOKHAV" b2="138 KV" b3="SABRATON" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BROOKHAV" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100757</SeqNum>
    <Name>DTX138.Connellsville.T62</Name>
    <LastEdit Timestamp="2025-09-18T09:57:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONNELSV" b2="138 KV" b3="BETHELBO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONNELSV" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONNELSV" b2="138 KV" b3="T62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100758</SeqNum>
    <Name>DTX138.FrenchCreek.T2</Name>
    <LastEdit Timestamp="2026-02-10T12:53:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENCHCR" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENCHCR" b2="138 KV" b3="B49" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRENCHCR" b2="138 KV" b3="BUSTIECB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FRENCHCR" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRENCHCR" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100759</SeqNum>
    <Name>DTX138.Gordon.T61</Name>
    <LastEdit Timestamp="2025-12-05T14:35:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDON" b2="138 KV" b3="B47" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDON" b2="138 KV" b3="MANIFOLD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GORDON" b2="138 KV" b3="T61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100760</SeqNum>
    <Name>DTX138.Gordon.T3</Name>
    <LastEdit Timestamp="2024-05-13T09:47:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDON" b2="138 KV" b3="2-3BUSTI" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GORDON" b2="138 KV" b3="ARDENLF1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDON" b2="138 KV" b3="B25" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GORDON" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100761</SeqNum>
    <Name>DTX138.Greenwood.T2</Name>
    <LastEdit Timestamp="2025-09-18T09:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWOO" b2="138 KV" b3="ABBUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENWOO" b2="138 KV" b3="BCBUSTIE" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GREENWOO" b2="138 KV" b3="GREENWD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENWOO" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100762</SeqNum>
    <Name>DTX138.Halfway.T2</Name>
    <LastEdit Timestamp="2025-09-18T09:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HALFWAY" b2="138 KV" b3="AB TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HALFWAY" b2="138 KV" b3="BC TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HALFWAY" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100767</SeqNum>
    <Name>DTX138.Amos.SCR1</Name>
    <LastEdit Timestamp="2025-09-18T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMOS" b2="138 KV" b3="SCR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100768</SeqNum>
    <Name>DTX138.Amos.SCR2</Name>
    <LastEdit Timestamp="2025-09-18T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMOS" b2="138 KV" b3="F2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMOS" b2="138 KV" b3="SCR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100769</SeqNum>
    <Name>DTX138.Aston.William1</Name>
    <LastEdit Timestamp="2025-09-18T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTON" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTON" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ASTON" b2="138 KV" b3="WILLIAM1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100770</SeqNum>
    <Name>DTX138.Aston.William2</Name>
    <LastEdit Timestamp="2025-09-18T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTON" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ASTON" b2="138 KV" b3="WILLIAM2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100771</SeqNum>
    <Name>DTX138.Aston.William3</Name>
    <LastEdit Timestamp="2025-09-18T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ASTON" b2="138 KV" b3="WILLIAM3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100772</SeqNum>
    <Name>DTX138.Azalea.Moment1</Name>
    <LastEdit Timestamp="2025-09-18T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AZALEA" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AZALEA" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="AZALEA" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AZALEA" b2="138 KV" b3="MOMENT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100773</SeqNum>
    <Name>DTX138.Azalea.Moment2</Name>
    <LastEdit Timestamp="2025-09-18T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AZALEA" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AZALEA" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AZALEA" b2="138 KV" b3="MOMENT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100774</SeqNum>
    <Name>DTX138.Bexley.T3</Name>
    <LastEdit Timestamp="2025-09-18T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEXLEY" b2="138 KV" b3="104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEXLEY" b2="138 KV" b3="105" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEXLEY" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100775</SeqNum>
    <Name>DTX138.Clinton.T2</Name>
    <LastEdit Timestamp="2025-09-18T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTOCS" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTOCS" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLINTOCS" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100776</SeqNum>
    <Name>DTX138.Clinton.T3</Name>
    <LastEdit Timestamp="2025-09-18T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTOCS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTOCS" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLINTOCS" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100777</SeqNum>
    <Name>DTX69.Cook.TR8</Name>
    <LastEdit Timestamp="2025-09-30T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="COOK" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COOK" b2="69 KV" b3="T7" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COOK" b2="69 KV" b3="TR8_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100778</SeqNum>
    <Name>DTX138.Corridor.XF3</Name>
    <LastEdit Timestamp="2025-09-18T09:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="101C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="101N" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CORRIDOR" b2="138 KV" b3="XF3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100779</SeqNum>
    <Name>DTX138.Corridor.XF4</Name>
    <LastEdit Timestamp="2025-09-18T09:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="101C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="138 KV" b3="101S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CORRIDOR" b2="138 KV" b3="XF4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100780</SeqNum>
    <Name>DTX138.Davidson.T1</Name>
    <LastEdit Timestamp="2025-09-18T09:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIDSON" b2="138 KV" b3="A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIDSON" b2="138 KV" b3="AF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAVIDSON" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100781</SeqNum>
    <Name>DTX138.Delano.T1</Name>
    <LastEdit Timestamp="2025-09-18T09:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELANO" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELANO" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DELANO" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100782</SeqNum>
    <Name>DTX138.EastBroadSt.T1</Name>
    <LastEdit Timestamp="2025-09-18T09:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBROAD" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBROAD" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EBROAD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100783</SeqNum>
    <Name>DTX138.EastBroadSt.T2</Name>
    <LastEdit Timestamp="2025-05-12T15:54:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBROAD" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBROAD" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EBROAD" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100784</SeqNum>
    <Name>DTX138.Freebyrd.XF1</Name>
    <LastEdit Timestamp="2025-09-18T09:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="FREEBYRD" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEBYRD" b2="138 KV" b3="Q1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEBYRD" b2="138 KV" b3="R1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FREEBYRD" b2="138 KV" b3="XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100785</SeqNum>
    <Name>DTX138.Freebyrd.XF2</Name>
    <LastEdit Timestamp="2025-09-22T14:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEBYRD" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEBYRD" b2="138 KV" b3="Q1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FREEBYRD" b2="138 KV" b3="XF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100786</SeqNum>
    <Name>DTX138.Freebyrd.XF3</Name>
    <LastEdit Timestamp="2025-09-22T14:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEBYRD" b2="138 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEBYRD" b2="138 KV" b3="Q4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FREEBYRD" b2="138 KV" b3="XF3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100787</SeqNum>
    <Name>DTX138.Freebyrd.XF4</Name>
    <LastEdit Timestamp="2025-09-22T14:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEBYRD" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREEBYRD" b2="138 KV" b3="R4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FREEBYRD" b2="138 KV" b3="XF4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100788</SeqNum>
    <Name>DTX138.Gahanna.T5</Name>
    <LastEdit Timestamp="2025-11-21T12:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="108" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="109" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GAHANNA" b2="138 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100789</SeqNum>
    <Name>DTX138.Gahanna.T6</Name>
    <LastEdit Timestamp="2026-01-27T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="111" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="112" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GAHANNA" b2="138 KV" b3="T6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100790</SeqNum>
    <Name>DTX138.Gahanna.T3</Name>
    <LastEdit Timestamp="2025-09-22T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="114" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="115" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GAHANNA" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100791</SeqNum>
    <Name>DTX138.Gahanna.T4</Name>
    <LastEdit Timestamp="2025-09-22T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="117" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAHANNA" b2="138 KV" b3="118" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GAHANNA" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100792</SeqNum>
    <Name>DTX138.Gay.T1</Name>
    <LastEdit Timestamp="2025-09-22T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAY" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAY" b2="138 KV" b3="105" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GAY" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100793</SeqNum>
    <Name>DTX138.Gay.T2</Name>
    <LastEdit Timestamp="2025-09-22T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAY" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAY" b2="138 KV" b3="104" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GAY" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100794</SeqNum>
    <Name>DTX138.Genoa.T1</Name>
    <LastEdit Timestamp="2025-09-22T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GENOA" b2="138 KV" b3="102C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GENOA" b2="138 KV" b3="102N" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GENOA" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100795</SeqNum>
    <Name>L138.Arsenal-Riazzi.Z101</Name>
    <LastEdit Timestamp="2025-06-20T15:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ARSENAL" b2="138 KV" b3="ARS-RIAZ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="138 KV" b3="TIE 2-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="138 KV" b3="TIE 3-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIAZZI" b2="138 KV" b3="TIE1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIAZZI" b2="138 KV" b3="TIE2-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100796</SeqNum>
    <Name>DTX138.Riazzi.T1</Name>
    <LastEdit Timestamp="2025-06-18T12:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIAZZI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIAZZI" b2="138 KV" b3="TIE1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIAZZI" b2="138 KV" b3="TIE1-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100797</SeqNum>
    <Name>DTX138.Riazzi.T2</Name>
    <LastEdit Timestamp="2025-06-19T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIAZZI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIAZZI" b2="138 KV" b3="TIE2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIAZZI" b2="138 KV" b3="TIE2-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100798</SeqNum>
    <Name>L138.OhioCentral-EastPoint-Culbertson</Name>
    <LastEdit Timestamp="2025-05-27T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CULBERTS" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CULBERTS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CULBERTS" b2="138 KV" b3="CUL-EPOI" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPOINT" b2="138 KV" b3="EPO-OHI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EPOINT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="E2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100799</SeqNum>
    <Name>DTX138.Culbertson.AMG1</Name>
    <LastEdit Timestamp="2025-05-27T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CULBERTS" b2="138 KV" b3="AMG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CULBERTS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CULBERTS" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100800</SeqNum>
    <Name>DTX138.Culbertson.AMG2</Name>
    <LastEdit Timestamp="2025-05-27T17:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CULBERTS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CULBERTS" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CULBERTS" b2="138 KV" b3="AMG2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100802</SeqNum>
    <Name>DTX138.Greif.T1</Name>
    <LastEdit Timestamp="2025-09-22T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREIF" b2="138 KV" b3="A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREIF" b2="138 KV" b3="D CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREIF" b2="138 KV" b3="T1LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100803</SeqNum>
    <Name>DTX138.Greif.T2</Name>
    <LastEdit Timestamp="2025-09-22T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREIF" b2="138 KV" b3="B CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREIF" b2="138 KV" b3="C CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREIF" b2="138 KV" b3="T2LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100804</SeqNum>
    <Name>DTX138.Jugstreet.SmithsMill</Name>
    <LastEdit Timestamp="2025-09-22T14:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JUGSTRET" b2="138 KV" b3="SMITHMIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100805</SeqNum>
    <Name>DTX138.Kammer.T6</Name>
    <LastEdit Timestamp="2025-09-22T14:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="J CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="J1 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KAMMER2" b2="138 KV" b3="T6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100806</SeqNum>
    <Name>DTX138.Kammer.T5</Name>
    <LastEdit Timestamp="2025-09-22T14:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KAMMER2" b2="138 KV" b3="T5 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100807</SeqNum>
    <Name>DTX138.Kammer.FGD1</Name>
    <LastEdit Timestamp="2025-09-22T14:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KAMMER2" b2="138 KV" b3="FGD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="J CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="J2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100808</SeqNum>
    <Name>DTX138.Kammer.FGD2</Name>
    <LastEdit Timestamp="2025-09-22T14:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KAMMER2" b2="138 KV" b3="FGD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="I CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="I1 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100809</SeqNum>
    <Name>DTX138.Karl.T1</Name>
    <LastEdit Timestamp="2025-09-23T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KARL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KARL" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KARL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100810</SeqNum>
    <Name>DTX138.Karl.T2</Name>
    <LastEdit Timestamp="2025-09-23T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KARL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KARL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KARL" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100811</SeqNum>
    <Name>DTX138.Karl.T3</Name>
    <LastEdit Timestamp="2025-09-23T11:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KARL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KARL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KARL" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100812</SeqNum>
    <Name>L138.WestSide-OliverPlow</Name>
    <LastEdit Timestamp="2025-05-16T12:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVERPL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="OLIVERPL" b2="138 KV" b3="OLI-WSI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSIDE" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100814</SeqNum>
    <Name>DTX138.Lardin.T61</Name>
    <LastEdit Timestamp="2025-09-23T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LARDIN" b2="138 KV" b3="L-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARDIN" b2="138 KV" b3="L-3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LARDIN" b2="138 KV" b3="T61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100815</SeqNum>
    <Name>DTX138.Peters.T61</Name>
    <LastEdit Timestamp="2025-09-23T12:50:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERS" b2="138 KV" b3="1-2B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PETERS" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERS" b2="138 KV" b3="UNIONJCT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100816</SeqNum>
    <Name>DTX138.MahansLane.T1</Name>
    <LastEdit Timestamp="2025-09-23T12:55:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAHANSLA" b2="138 KV" b3="202 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAHANSLA" b2="138 KV" b3="252 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAHANSLA" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100818</SeqNum>
    <Name>DTX230.Damascus.T1&amp;4</Name>
    <LastEdit Timestamp="2025-09-23T11:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAMASCUS" b2="230 KV" b3="BUSTIEBA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAMASCUS" b2="230 KV" b3="BUSTIEDC" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DAMASCUS" b2="230 KV" b3="CAP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAMASCUS" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAMASCUS" b2="230 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100819</SeqNum>
    <Name>DTX138.Dupont.T1&amp;3</Name>
    <LastEdit Timestamp="2024-11-20T10:58:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPONT" b2="138 KV" b3="B94" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPONT" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUPONT" b2="138 KV" b3="DUP-GEP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUPONT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUPONT" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DUPONT" b2="138 KV" b3="W94_BYP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100820</SeqNum>
    <Name>DTX138.Dupont.T2&amp;4</Name>
    <LastEdit Timestamp="2024-11-20T10:58:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPONT" b2="138 KV" b3="B92" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUPONT" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DUPONT" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUPONT" b2="138 KV" b3="DUP-LAR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DUPONT" b2="138 KV" b3="EDLWN_BP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUPONT" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DUPONT" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100821</SeqNum>
    <Name>L138.Kirby-Crissinger</Name>
    <LastEdit Timestamp="2025-07-07T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISS" b2="138 KV" b3="B102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRISS" b2="138 KV" b3="B122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRBY" b2="138 KV" b3="18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRBY" b2="138 KV" b3="24" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRISS" b2="138 KV" b3="CRI-KIRB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100822</SeqNum>
    <Name>DTX138.Hempfield.T61</Name>
    <LastEdit Timestamp="2025-05-13T14:21:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEMPFIEL" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEMPFIEL" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEMPFIEL" b2="138 KV" b3="HEM-NGR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HEMPFIEL" b2="138 KV" b3="T61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100823</SeqNum>
    <Name>DTX138.Hempfield.T2&amp;62</Name>
    <LastEdit Timestamp="2025-05-13T14:22:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEMPFIEL" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEMPFIEL" b2="138 KV" b3="HEM-SEW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEMPFIEL" b2="138 KV" b3="SEWICKLE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HEMPFIEL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HEMPFIEL" b2="138 KV" b3="T62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100824</SeqNum>
    <Name>DTX138.Huntingdon.T2&amp;62</Name>
    <LastEdit Timestamp="2025-09-23T12:56:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTINGD" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTINGD" b2="138 KV" b3="ROBBINS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUNTINGD" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUNTINGD" b2="138 KV" b3="T62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100825</SeqNum>
    <Name>138/25.IronBridge.T1 &amp; 61</Name>
    <LastEdit Timestamp="2026-05-08T10:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONBRID" b2="25 KV" b3="B1TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONBRID" b2="138 KV" b3="B40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONBRID" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IRONBRID" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="X" Type="XF" b1="IRONBRID" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100826</SeqNum>
    <Name>DTX138.Kittanning.T1&amp;61</Name>
    <LastEdit Timestamp="2025-09-23T12:56:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTANNI" b2="138 KV" b3="ARMSTRON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTANNI" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KITTANNI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KITTANNI" b2="138 KV" b3="T61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100827</SeqNum>
    <Name>DTX138.Kiesters.T62</Name>
    <LastEdit Timestamp="2025-09-23T12:56:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEISTERS" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEISTERS" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEISTERS" b2="138 KV" b3="T62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100828</SeqNum>
    <Name>DTX138.Luxor.T62</Name>
    <LastEdit Timestamp="2025-09-30T15:59:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LUXOR" b2="138 KV" b3="BRACKJCT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUXOR" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LUXOR" b2="138 KV" b3="T62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100829</SeqNum>
    <Name>DTX138.Mcalpin.T1</Name>
    <LastEdit Timestamp="2025-09-30T16:00:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCALPIN" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCALPIN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCALPIN" b2="138 KV" b3="WHITEJCT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100830</SeqNum>
    <Name>DTX138.Mccalmont.T2A</Name>
    <LastEdit Timestamp="2025-09-04T14:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCALMON" b2="138 KV" b3="1-2BUSTI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCALMON" b2="138 KV" b3="2-3BUSTI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCALMON" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCCALMON" b2="138 KV" b3="T2A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100831</SeqNum>
    <Name>DTX138.Mccalmont.T3A&amp;63</Name>
    <LastEdit Timestamp="2025-09-30T16:00:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCALMON" b2="138 KV" b3="2-3BUSTI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCALMON" b2="138 KV" b3="AKSTEEL3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCALMON" b2="138 KV" b3="KILGO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCCALMON" b2="138 KV" b3="T3A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCCALMON" b2="138 KV" b3="T63" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100832</SeqNum>
    <Name>DTX230.Milesburg.T81</Name>
    <LastEdit Timestamp="2025-09-30T16:01:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILESBUR" b2="230 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILESBUR" b2="230 KV" b3="DALESUMM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILESBUR" b2="230 KV" b3="T81" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100833</SeqNum>
    <Name>DTX230.Milesburg.T82</Name>
    <LastEdit Timestamp="2025-09-30T16:02:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILESBUR" b2="230 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILESBUR" b2="230 KV" b3="MOSHANNO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILESBUR" b2="230 KV" b3="T82" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100834</SeqNum>
    <Name>DTX230.Monocacy.T5</Name>
    <LastEdit Timestamp="2025-09-30T16:02:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONOCACY" b2="230 KV" b3="BUSTIEAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONOCACY" b2="230 KV" b3="EAGLEHEA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONOCACY" b2="230 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100835</SeqNum>
    <Name>DTX230.Mtairy.T3</Name>
    <LastEdit Timestamp="2025-09-30T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MTAIRY" b2="230 KV" b3="BUSTIE23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTAIRY" b2="230 KV" b3="BUSTIE34" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTAIRY" b2="230 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100836</SeqNum>
    <Name>DTX230.Mtairy.T4</Name>
    <LastEdit Timestamp="2025-10-03T13:36:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MTAIRY" b2="230 KV" b3="BUSTIE34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTAIRY" b2="230 KV" b3="DAMASCUS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTAIRY" b2="230 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100837</SeqNum>
    <Name>DTX138.NorthPetersburg.T2</Name>
    <LastEdit Timestamp="2025-10-03T13:37:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPETERSB" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPETERSB" b2="138 KV" b3="HARDY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPETERSB" b2="34.5 KV" b3="T2LCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="NPETERSB" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100838</SeqNum>
    <Name>DTX138.NorthPetersburg.T1</Name>
    <LastEdit Timestamp="2025-10-03T13:38:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPETERSB" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPETERSB" b2="138 KV" b3="SENCAV_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPETERSB" b2="34.5 KV" b3="T1LCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="NPETERSB" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100839</SeqNum>
    <Name>DTX138.Padencity.T2</Name>
    <LastEdit Timestamp="2025-08-25T12:39:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PADENCIT" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PADENCIT" b2="138 KV" b3="NEWMARTI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PADENCIT" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100840</SeqNum>
    <Name>DTX138.Parkersburg.T3&amp;4</Name>
    <LastEdit Timestamp="2026-01-09T15:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PARKERSB" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARKERSB" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUGRUN" b2="138 KV" b3="JUG-PAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PARKERSB" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PARKERSB" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100841</SeqNum>
    <Name>DTX138.Pierpont.T1</Name>
    <LastEdit Timestamp="2024-11-13T09:50:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERPONT" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERPONT" b2="138 KV" b3="BROOKHAV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PIERPONT" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100842</SeqNum>
    <Name>DTX138.Redbud.T2&amp;3</Name>
    <LastEdit Timestamp="2024-05-15T09:44:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="REDBUD" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBUD" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBUD" b2="34.5 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REDBUD" b2="34.5 KV" b3="LOAD2" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDBUD" b2="138 KV" b3="RED-WWI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REDBUD" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBUD" b2="138 KV" b3="WWINCHES" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100843</SeqNum>
    <Name>DTX138.Redbud.T1&amp;4</Name>
    <LastEdit Timestamp="2025-07-11T12:48:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="REDBUD" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBUD" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBUD" b2="34.5 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="REDBUD" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDBUD" b2="138 KV" b3="GREENWOO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REDBUD" b2="34.5 KV" b3="LOAD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REDBUD" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100844</SeqNum>
    <Name>DTX138.RidgewayAPS.T1</Name>
    <LastEdit Timestamp="2025-10-02T10:31:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDG APS" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDG APS" b2="138 KV" b3="PAPERCIT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIDG APS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100845</SeqNum>
    <Name>DTX230.Shingletown.T81</Name>
    <LastEdit Timestamp="2025-10-01T16:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHINGLET" b2="230 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHINGLET" b2="230 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHAWVILL" b2="230 KV" b3="SHA-SHI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHINGLET" b2="230 KV" b3="T81" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100846</SeqNum>
    <Name>DTX138.Smith.T2&amp;3</Name>
    <LastEdit Timestamp="2026-01-16T12:47:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SMIT APS" b2="25 KV" b3="B2TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMIT APS" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SMIT APS" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMIT APS" b2="138 KV" b3="NORTH FA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SMIT APS" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMIT APS" b2="138 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100847</SeqNum>
    <Name>DTX138.Trissler.T3</Name>
    <LastEdit Timestamp="2024-05-15T09:35:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISSLER" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISSLER" b2="138 KV" b3="B604" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELMONT" b2="138 KV" b3="BEL-TRI2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRISSLER" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100848</SeqNum>
    <Name>L138.Woodspoint-Aero1</Name>
    <LastEdit Timestamp="2025-11-21T12:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AERO1" b2="138 KV" b3="CB964" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AERO1" b2="138 KV" b3="CB966" />
      <ContingencyEquipment Action="L" Type="LN" b1="AERO1" b2="138 KV" b3="AER-WOOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSPNT" b2="138 KV" b3="CB824" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSPNT" b2="138 KV" b3="CB826" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100849</SeqNum>
    <Name>DTX138.WaldoRun.SHERWD1</Name>
    <LastEdit Timestamp="2025-10-02T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALDORUN" b2="138 KV" b3="SHERWD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100850</SeqNum>
    <Name>DTX138.Opequon.T1&amp;2</Name>
    <LastEdit Timestamp="2025-12-19T11:53:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OPEQUON" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPEQUON" b2="138 KV" b3="KEARNEYS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OPEQUON" b2="34.5 KV" b3="T1LSCB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OPEQUON" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="OPEQUON" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100851</SeqNum>
    <Name>DTX138.WashingtonAPS.T61</Name>
    <LastEdit Timestamp="2026-01-16T12:50:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WASH APS" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WASH APS" b2="138 KV" b3="DUTCHFOR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WASH APS" b2="138 KV" b3="T61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100852</SeqNum>
    <Name>DTX138.WhiteValley.T1&amp;61</Name>
    <LastEdit Timestamp="2025-10-02T10:37:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEVAL" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEVAL" b2="138 KV" b3="SPRING" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHITEVAL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHITEVAL" b2="138 KV" b3="T61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100853</SeqNum>
    <Name>DTX138.WhiteValley.T62</Name>
    <LastEdit Timestamp="2025-10-02T10:38:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEVAL" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEVAL" b2="138 KV" b3="HARRCITY" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHITEVAL" b2="138 KV" b3="T62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100854</SeqNum>
    <Name>DTX138.WestWaynesboro.T61</Name>
    <LastEdit Timestamp="2025-10-02T10:37:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WWAYNESB" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWAYNESB" b2="138 KV" b3="FAYETTEV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WWAYNESB" b2="138 KV" b3="T61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100855</SeqNum>
    <Name>DTX138.WestWaynesboro.T2&amp;62</Name>
    <LastEdit Timestamp="2025-10-02T10:36:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WWAYNESB" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WWAYNESB" b2="138 KV" b3="E WAYNES" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WWAYNESB" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WWAYNESB" b2="138 KV" b3="T62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100856</SeqNum>
    <Name>DTX138.Youngwood.T1&amp;61</Name>
    <LastEdit Timestamp="2025-10-02T10:38:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="YOUNGWOO" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="YOUNGWOO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="YOUNGWOO" b2="138 KV" b3="T61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YOUNGWOO" b2="138 KV" b3="YUKON" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100857</SeqNum>
    <Name>DTX138.Youngwood.T2&amp;62</Name>
    <LastEdit Timestamp="2025-10-02T10:39:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="YOUNGWOO" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YOUNGWOO" b2="138 KV" b3="EASTGATE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="YOUNGWOO" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="YOUNGWOO" b2="138 KV" b3="T62" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100859</SeqNum>
    <Name>L230.WardAve-Crosswicks-ChesterF-Mansfield.2339</Name>
    <LastEdit Timestamp="2025-10-17T12:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHESTERF" b2="230 KV" b3="T-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTERF" b2="230 KV" b3="CHE-CROX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSWIC" b2="230 KV" b3="T-2CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CROSSWIC" b2="230 KV" b3="TXR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFLD" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFLD" b2="230 KV" b3="1-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTERF" b2="230 KV" b3="CHE-MANS" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROSSWIC" b2="230 KV" b3="CRO-WARX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARDAV" b2="230 KV" b3="P-H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100860</SeqNum>
    <Name>DTX138.Knollwood.BK1</Name>
    <LastEdit Timestamp="2025-10-02T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09KNOLLW" b2="138 KV" b3="A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09KNOLLW" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09KNOLLW" b2="138 KV" b3="BK-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100861</SeqNum>
    <Name>DTX69.FaceRock.KINZ14</Name>
    <LastEdit Timestamp="2025-10-02T10:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="CAP1-K14" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FACEROCK" b2="69 KV" b3="KINZ14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="KINZ14NB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FACEROCK" b2="69 KV" b3="QVIL2 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FACEROCK" b2="69 KV" b3="QVIL_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100862</SeqNum>
    <Name>DTX138.Carlisle.BK2</Name>
    <LastEdit Timestamp="2025-10-02T10:30:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09NCARLI" b2="138 KV" b3="BK-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09NCARLI" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09NCARLI" b2="138 KV" b3="P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100863</SeqNum>
    <Name>DTX138.Needmore.BK3</Name>
    <LastEdit Timestamp="2025-10-02T10:32:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09NEEDMO" b2="138 KV" b3="A_1CA869" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09NEEDMO" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09NEEDMO" b2="138 KV" b3="BK-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100864</SeqNum>
    <Name>DTX138.Eldean1.BK3</Name>
    <LastEdit Timestamp="2025-10-02T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELDEAN1" b2="138 KV" b3="BK-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDEAN1" b2="138 KV" b3="OR-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDEAN1" b2="138 KV" b3="OR-F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100865</SeqNum>
    <Name>DTX138.Eldean1.BK2</Name>
    <LastEdit Timestamp="2025-10-02T10:30:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELDEAN1" b2="138 KV" b3="BK-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDEAN1" b2="138 KV" b3="OR-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDEAN1" b2="138 KV" b3="OR-C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100869</SeqNum>
    <Name>DTX138.TownSend.ONE</Name>
    <LastEdit Timestamp="2025-05-19T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWNSEND" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWNSEND" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TOWNSEND" b2="138 KV" b3="ONE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100870</SeqNum>
    <Name>DTX138.TownSend.MidleTown</Name>
    <LastEdit Timestamp="2025-10-02T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWNSEND" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWNSEND" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TOWNSEND" b2="138 KV" b3="MIDLETWN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100871</SeqNum>
    <Name>DTX69.Tasley.LoadT1</Name>
    <LastEdit Timestamp="2025-05-16T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TASLEY" b2="69 KV" b3="7480" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TASLEY" b2="69 KV" b3="7490" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TASLEY" b2="69 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100872</SeqNum>
    <Name>DTX69.Tasley.LoadT4</Name>
    <LastEdit Timestamp="2025-05-16T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TASLEY" b2="69 KV" b3="7460" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TASLEY" b2="69 KV" b3="7470" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TASLEY" b2="69 KV" b3="LOADT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100873</SeqNum>
    <Name>DTX138.Steele.T3</Name>
    <LastEdit Timestamp="2025-05-19T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="8250" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="8280" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STEELE" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100874</SeqNum>
    <Name>DTX138.Motiva.Load</Name>
    <LastEdit Timestamp="2025-05-19T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTIVA" b2="138 KV" b3="130 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOTIVA" b2="138 KV" b3="131 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MOTIVA" b2="138 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100875</SeqNum>
    <Name>DTX138.MillTown.LoadT3</Name>
    <LastEdit Timestamp="2024-05-31T15:03:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLTOWN" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLTOWN" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILLTOWN" b2="138 KV" b3="LOADT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100876</SeqNum>
    <Name>DTX138.MillTown.LoadT4</Name>
    <LastEdit Timestamp="2024-05-31T15:03:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLTOWN" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLTOWN" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILLTOWN" b2="138 KV" b3="LOADT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100877</SeqNum>
    <Name>DTX138.Milford.LoadT1</Name>
    <LastEdit Timestamp="2025-08-11T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="138 KV" b3="8620" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="138 KV" b3="8630" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100878</SeqNum>
    <Name>DTX138.Milford.LoadT2(LX)</Name>
    <LastEdit Timestamp="2025-09-16T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="138 KV" b3="8640" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MILFORD" b2="138 KV" b3="LOADT2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MILFORD" b2="138 KV" b3="LOADT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100879</SeqNum>
    <Name>DTX138.Milford.Load13702</Name>
    <LastEdit Timestamp="2025-05-16T12:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILFORD" b2="138 KV" b3="13702" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILFORD" b2="138 KV" b3="8630" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100880</SeqNum>
    <Name>DTX69.Kellam.T1</Name>
    <LastEdit Timestamp="2025-05-19T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KELLAM" b2="69 KV" b3="71" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELLAM" b2="69 KV" b3="72" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KELLAM" b2="69 KV" b3="T1 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100881</SeqNum>
    <Name>DTX69.Kellam.T2</Name>
    <LastEdit Timestamp="2025-05-19T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KELLAM" b2="69 KV" b3="70" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELLAM" b2="69 KV" b3="75" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELLAM" b2="69 KV" b3="76" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="KELLAM" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KELLAM" b2="69 KV" b3="T2 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100882</SeqNum>
    <Name>DTX138.NewCastle.Load13803</Name>
    <LastEdit Timestamp="2025-05-19T14:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWCASTL" b2="138 KV" b3="13803" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100883</SeqNum>
    <Name>DTX138.OceanBay.LoadT1</Name>
    <LastEdit Timestamp="2024-08-21T16:23:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANBAY" b2="138 KV" b3="173" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANBAY" b2="138 KV" b3="174" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OCEANBAY" b2="138 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100884</SeqNum>
    <Name>138/12.OceanBay.T2 + OceanBay.SP</Name>
    <LastEdit Timestamp="2024-09-10T15:05:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANBAY" b2="138 KV" b3="170" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANBAY" b2="138 KV" b3="171" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OCEANBAY" b2="12 KV" b3="LOADT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OCEANBAY" b2="12 KV" b3="OCEABA" />
      <ContingencyEquipment Action="X" Type="XF" b1="OCEANBAY" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100885</SeqNum>
    <Name>DTX138.Robinsonville.Angola</Name>
    <LastEdit Timestamp="2021-01-20T16:55:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBINS" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBINS" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROBINS" b2="138 KV" b3="ANGOLA" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="ROBINS" b2="138 KV" b3="ANGOLA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100886</SeqNum>
    <Name>DTX69.BridgeVille.LoadT1</Name>
    <LastEdit Timestamp="2025-05-19T14:52:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEVI" b2="69 KV" b3="CB60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEVI" b2="69 KV" b3="CB61" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRIDGEVI" b2="69 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100887</SeqNum>
    <Name>DTX69.BridgeVille.LoadT2</Name>
    <LastEdit Timestamp="2025-05-19T14:53:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="BRIDGEVI" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BRIDGEVI" b2="69 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEVI" b2="69 KV" b3="CB61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEVI" b2="69 KV" b3="CB62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIDGEVI" b2="69 KV" b3="CB63" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRIDGEVI" b2="69 KV" b3="LOADT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100888</SeqNum>
    <Name>DTX138.CarrCroft.T2</Name>
    <LastEdit Timestamp="2025-05-16T12:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARRCROF" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARRCROF" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARRCROF" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100889</SeqNum>
    <Name>DTX138.CarrCroft.Load13823</Name>
    <LastEdit Timestamp="2025-05-16T12:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARRCROF" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARRCROF" b2="138 KV" b3="13823" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARRCROF" b2="138 KV" b3="142" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100890</SeqNum>
    <Name>DTX138.Bethany.Load</Name>
    <LastEdit Timestamp="2024-05-31T14:45:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="138 KV" b3="132CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHANY" b2="138 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100891</SeqNum>
    <Name>DTX69.Bethany.Load2</Name>
    <LastEdit Timestamp="2025-08-22T10:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="69 KV" b3="7510" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="69 KV" b3="7550" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHANY" b2="69 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100893</SeqNum>
    <Name>DTX69.Bethany.Load35</Name>
    <LastEdit Timestamp="2025-05-19T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="69 KV" b3="7530" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="69 KV" b3="7560" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHANY" b2="69 KV" b3="LOAD35" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100894</SeqNum>
    <Name>DTX69.Beaglin.T1</Name>
    <LastEdit Timestamp="2021-01-20T16:57:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAGLIN" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAGLIN" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAGLIN" b2="69 KV" b3="T1LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="BEAGLIN" b2="69 KV" b3="T1LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100895</SeqNum>
    <Name>DTX69.Beaglin.T2</Name>
    <LastEdit Timestamp="2021-01-20T16:57:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAGLIN" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAGLIN" b2="69 KV" b3="65" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAGLIN" b2="69 KV" b3="T2LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="BEAGLIN" b2="69 KV" b3="T2LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100896</SeqNum>
    <Name>DTX69.Stevensville.T1</Name>
    <LastEdit Timestamp="2025-05-19T14:57:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STVNSVIL" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STVNSVIL" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STVNSVIL" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100897</SeqNum>
    <Name>DTX69.Absecon.Load1</Name>
    <LastEdit Timestamp="2025-07-07T10:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ABSECON" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ABSECON" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ABSECON" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ABSECON" b2="69 KV" b3="PEARSTCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ABSECON" b2="69 KV" b3="PEARSTSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100898</SeqNum>
    <Name>DTX69.Absecon.Load2</Name>
    <LastEdit Timestamp="2025-07-07T10:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ABSECON" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ABSECON" b2="69 KV" b3="LOAD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ABSECON" b2="69 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ABSECON" b2="69 KV" b3="OAKSTCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ABSECON" b2="69 KV" b3="OAKSTSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100900</SeqNum>
    <Name>DTX69.Atco.LoadBus4 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-05-19T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="ATCO" b2="69 KV" b3="ATCO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ATCO" b2="69 KV" b3="BUS4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATCO" b2="69 KV" b3="CAPGCBG" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ATCO" b2="69 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100901</SeqNum>
    <Name>DTX69.Barnegat.T1</Name>
    <LastEdit Timestamp="2025-07-03T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BARNEGAT" b2="69 KV" b3="CB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARNEGAT" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BARNEGAT" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100903</SeqNum>
    <Name>DTX69.Beckett.T2</Name>
    <LastEdit Timestamp="2024-09-06T15:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKETT" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKETT" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BECKETT" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100904</SeqNum>
    <Name>DTX69.Berlin.IBus</Name>
    <LastEdit Timestamp="2025-07-03T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERLIN" b2="69 KV" b3="IBUS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BERLIN" b2="69 KV" b3="R" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100906</SeqNum>
    <Name>DTX69.CarllsCorner.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLLS" b2="69 KV" b3="CAPOCBN" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CARLLS" b2="69 KV" b3="CARLLS" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CARLLS" b2="69 KV" b3="CUMBERLF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLLS" b2="69 KV" b3="CUMB_CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CARLLS" b2="69 KV" b3="S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARLLS" b2="69 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100907</SeqNum>
    <Name>DTX69.CarllsCorner.T3 </Name>
    <LastEdit Timestamp="2022-11-14T16:19:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LT" Type="LOAD" b1="CARLLS" b2="69 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLLS" b2="69 KV" b3="W_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100908</SeqNum>
    <Name>DTX69.Cedar.Load7</Name>
    <LastEdit Timestamp="2023-08-25T07:43:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="CEDAR" b2="69 KV" b3="CEDAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="FF CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB KK" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CEDAR" b2="69 KV" b3="LOAD7" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="CEDAR" b2="69 KV" b3="LOAD7" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CEDAR" b2="69 KV" b3="MOBILCAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="OCB V" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100909</SeqNum>
    <Name>DTX69.Cedar.Load6</Name>
    <LastEdit Timestamp="2021-04-23T12:23:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB EE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDAR" b2="69 KV" b3="GCB J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CEDAR" b2="69 KV" b3="LOAD6" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="CEDAR" b2="69 KV" b3="LOAD6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100910</SeqNum>
    <Name>DTX230.Chambers.Bus3</Name>
    <LastEdit Timestamp="2021-04-23T12:12:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHAMBERS" b2="230 KV" b3="BUS3" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="CHAMBERS" b2="230 KV" b3="BUS3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBERS" b2="230 KV" b3="BUSGCBB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBERS" b2="230 KV" b3="BUSGCBD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100911</SeqNum>
    <Name>DTX230.Chambers.Bus4</Name>
    <LastEdit Timestamp="2021-04-23T12:12:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHAMBERS" b2="230 KV" b3="BUS4" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="CHAMBERS" b2="230 KV" b3="BUS4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBERS" b2="230 KV" b3="BUSGCBC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBERS" b2="230 KV" b3="BUSGCBE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100912</SeqNum>
    <Name>DTX69.ChurchTown.Bus1</Name>
    <LastEdit Timestamp="2021-04-23T12:12:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHURCHTO" b2="69 KV" b3="BUS1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="CHURCHTO" b2="69 KV" b3="BUS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="Q" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100913</SeqNum>
    <Name>DTX69.ChurchTown.T5</Name>
    <LastEdit Timestamp="2021-04-23T12:12:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="HP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="JN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHURCHTO" b2="69 KV" b3="T5" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="CHURCHTO" b2="69 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100914</SeqNum>
    <Name>DTX69.Corson.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-03T13:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CORSON" b2="69 KV" b3="DIS I" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CORSON" b2="69 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100916</SeqNum>
    <Name>DTX69.Corson.T3</Name>
    <LastEdit Timestamp="2025-07-03T13:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CORSON" b2="69 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CORSON" b2="69 KV" b3="T3 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100917</SeqNum>
    <Name>DTX69.Court.T1</Name>
    <LastEdit Timestamp="2025-07-03T13:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="COURT" b2="69 KV" b3="DIS G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COURT" b2="69 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COURT" b2="69 KV" b3="R" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COURT" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100918</SeqNum>
    <Name>DTX69.Court.T3</Name>
    <LastEdit Timestamp="2025-07-03T13:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="COURT" b2="69 KV" b3="DIS L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COURT" b2="69 KV" b3="P" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COURT" b2="69 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100919</SeqNum>
    <Name>DTX69.EggHarbor.T1</Name>
    <LastEdit Timestamp="2025-07-03T13:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EGGHARBO" b2="69 KV" b3="D CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EGGHARBO" b2="69 KV" b3="E CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EGGHARBO" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100920</SeqNum>
    <Name>DTX69.Fairton.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-05-19T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAIRTON" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FAIRTON" b2="69 KV" b3="T1-LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100921</SeqNum>
    <Name>DTX69.Fairton.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-05-19T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAIRTON" b2="69 KV" b3="I" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FAIRTON" b2="69 KV" b3="T2-LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100923</SeqNum>
    <Name>L138.Varner-Wilmingt</Name>
    <LastEdit Timestamp="2025-05-30T14:58:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VARNRAEP" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VARNRAEP" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="VARNRAEP" b2="138 KV" b3="VAR-WILM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILMINGT" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100925</SeqNum>
    <Name>DTX230.Chickahominy.TX3</Name>
    <LastEdit Timestamp="2025-05-30T14:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="H322" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHICKHOM" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHICKHOM" b2="36.5 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100927</SeqNum>
    <Name>ChurchLand.SR1</Name>
    <LastEdit Timestamp="2025-05-19T14:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CHRCHLND" b2="230 KV" b3="SR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHRCHLND" b2="230 KV" b3="SR152" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100928</SeqNum>
    <Name>Delta.138.Cap1+Cap2</Name>
    <LastEdit Timestamp="2025-09-02T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="DELTA" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DELTA" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELTA" b2="138 KV" b3="CS14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELTA" b2="138 KV" b3="CS20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100933</SeqNum>
    <Name>L115.PrGeorge-Mnpst-FtLee-Sisky-TmplAv-Harvell.97</Name>
    <LastEdit Timestamp="2025-07-10T10:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FORTLEE" b2="115 KV" b3="97B" />
      <ContingencyEquipment Action="L" Type="LN" b1="FORTLEE" b2="115 KV" b3="FOR-MAIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORTLEE" b2="115 KV" b3="H172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORTLEE" b2="115 KV" b3="H272" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORTLEE" b2="115 KV" b3="H372" />
      <ContingencyEquipment Action="X" Type="XF" b1="FORTLEE" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FORTLEE" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="FORTLEE" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FORTLEE" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="FORTLEE" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FORTLEE" b2="13 KV" b3="TX3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVELL" b2="115 KV" b3="9742" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARVELL" b2="115 KV" b3="97A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINPOST" b2="115 KV" b3="H102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINPOST" b2="115 KV" b3="H202" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAINPOST" b2="115 KV" b3="MAI-PRGE" />
      <ContingencyEquipment Action="X" Type="XF" b1="MAINPOST" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAINPOST" b2="13.2 KV" b3="TX1LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="MAINPOST" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAINPOST" b2="13.2 KV" b3="TX2LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRGEORGE" b2="115 KV" b3="97T121" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRGEORGE" b2="115 KV" b3="L1T97" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SISISKY" b2="13.2 KV" b3="CAP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SISISKY" b2="13.2 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SISISKY" b2="13.2 KV" b3="SC161-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SISISKY" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SISISKY" b2="115 KV" b3="97B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TEMPLEAV" b2="115 KV" b3="H182" />
      <ContingencyEquipment Action="X" Type="XF" b1="TEMPLEAV" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TEMPLEAV" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100934</SeqNum>
    <Name>DTX69.Lamb.T1</Name>
    <LastEdit Timestamp="2025-07-07T10:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMB" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMB" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAMB" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100935</SeqNum>
    <Name>DTX69.Laurel.Bus4</Name>
    <LastEdit Timestamp="2025-07-03T13:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAUREL" b2="69 KV" b3="BUS4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAUREL" b2="69 KV" b3="T4 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100936</SeqNum>
    <Name>DTX69.LenoxAE.Load1</Name>
    <LastEdit Timestamp="2025-07-03T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LENOX AE" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LENOX AE" b2="69 KV" b3="M DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100937</SeqNum>
    <Name>DTX69.Marven.T1Load</Name>
    <LastEdit Timestamp="2025-07-03T14:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARVENAE" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARVENAE" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARVENAE" b2="69 KV" b3="T1 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MARVENAE" b2="69 KV" b3="T1 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MARVENAE" b2="69 KV" b3="T1 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100938</SeqNum>
    <Name>DTX69.Marven.T2Load</Name>
    <LastEdit Timestamp="2025-07-03T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARVENAE" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARVENAE" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARVENAE" b2="69 KV" b3="T2 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MARVENAE" b2="69 KV" b3="T2 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MARVENAE" b2="69 KV" b3="T2 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100939</SeqNum>
    <Name>DTX69.Marven.T3Load</Name>
    <LastEdit Timestamp="2025-07-03T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARVENAE" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARVENAE" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARVENAE" b2="69 KV" b3="T3 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MARVENAE" b2="69 KV" b3="T3 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MARVENAE" b2="69 KV" b3="T3 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100940</SeqNum>
    <Name>DTX69.Mickleton.T2Load</Name>
    <LastEdit Timestamp="2021-04-23T12:15:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="PP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="QQ" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MICKLETO" b2="69 KV" b3="T2 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MICKLETO" b2="69 KV" b3="T2 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100941</SeqNum>
    <Name>DTX69.Mickleton.T5Load</Name>
    <LastEdit Timestamp="2021-04-23T12:15:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="JJ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="69 KV" b3="KK" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MICKLETO" b2="69 KV" b3="T5 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MICKLETO" b2="69 KV" b3="T5 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100942</SeqNum>
    <Name>DTX69.MossMill.T1</Name>
    <LastEdit Timestamp="2021-04-23T12:15:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSSMILL" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSSMILL" b2="69 KV" b3="N" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MOSSMILL" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MOSSMILL" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100943</SeqNum>
    <Name>DTX69.MossMill.T2</Name>
    <LastEdit Timestamp="2021-04-23T12:16:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSSMILL" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSSMILL" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MOSSMILL" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MOSSMILL" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100944</SeqNum>
    <Name>DTX69.NewPort.Load1</Name>
    <LastEdit Timestamp="2025-07-03T14:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="NEWPORT" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPORT" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWPORT" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPORT" b2="69 KV" b3="OCB G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPORT" b2="69 KV" b3="OCB H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100945</SeqNum>
    <Name>DTX69.Ontario.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-01T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ONTARIO" b2="69 KV" b3="DIS H" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ONTARIO" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONTARIO" b2="69 KV" b3="WIND" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ONTARIO" b2="69 KV" b3="WINDPWR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100946</SeqNum>
    <Name>DTX69.Ontario.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-01T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ONTARIO" b2="69 KV" b3="DIS G" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ONTARIO" b2="69 KV" b3="GEN_DUM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ONTARIO" b2="69 KV" b3="LOAD2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ONTARIO" b2="69 KV" b3="MIDTWNGT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100948</SeqNum>
    <Name>DTX69.PaulsBoro.Load2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-10T16:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="PAULSBRO" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PAULSBRO" b2="69 KV" b3="LOAD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAULSBRO" b2="69 KV" b3="OCB V" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PAULSBRO" b2="69 KV" b3="Y" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100949</SeqNum>
    <Name>DTX69.Peermont.T1</Name>
    <LastEdit Timestamp="2021-04-23T12:16:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEERMONT" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEERMONT" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEERMONT" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="PEERMONT" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100950</SeqNum>
    <Name>DTX69.Peermont.T2</Name>
    <LastEdit Timestamp="2021-04-23T12:17:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEERMONT" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEERMONT" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEERMONT" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="PEERMONT" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100952</SeqNum>
    <Name>DTX69.PineHill.Bus1(Sctnlz)</Name>
    <LastEdit Timestamp="2021-04-23T12:17:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PINEHILL" b2="69 KV" b3="1BUS" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="PINEHILL" b2="69 KV" b3="1BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEHILL" b2="69 KV" b3="CAPOCBD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PINEHILL" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PINEHILL" b2="69 KV" b3="PINEHL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100953</SeqNum>
    <Name>DTX69.PineHill.Bus2(Sctnlz)</Name>
    <LastEdit Timestamp="2021-04-23T12:17:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PINEHILL" b2="69 KV" b3="3BUS" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="PINEHILL" b2="69 KV" b3="3BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEHILL" b2="69 KV" b3="CAPOCBD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PINEHILL" b2="69 KV" b3="I" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PINEHILL" b2="69 KV" b3="PINEHL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100954</SeqNum>
    <Name>DTX69.PVille.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2023-02-17T11:30:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="PVILLE" b2="69 KV" b3="P DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PVILLE" b2="69 KV" b3="T4" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="PVILLE" b2="69 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100957</SeqNum>
    <Name>DTX69.PVille.T5 (Sctnlz)</Name>
    <LastEdit Timestamp="2021-04-23T11:27:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="PVILLE" b2="69 KV" b3="H DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PVILLE" b2="69 KV" b3="T5" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="PVILLE" b2="69 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100958</SeqNum>
    <Name>L138.Brookside-Bethel</Name>
    <LastEdit Timestamp="2025-05-19T15:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHEL2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHEL2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSDE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BETHEL2" b2="138 KV" b3="BET-BRO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BROOKSDE" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100960</SeqNum>
    <Name>DTX.Cole.T3</Name>
    <LastEdit Timestamp="2025-10-02T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="138 KV" b3="J1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COLE" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100965</SeqNum>
    <Name>DTX138.Beatty.T5</Name>
    <LastEdit Timestamp="2025-07-14T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="M2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEATTY" b2="138 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100967</SeqNum>
    <Name>L230.BrandonShores-Riverside.2344</Name>
    <LastEdit Timestamp="2026-01-07T10:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="2344 OCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="23472344" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDONS" b2="230 KV" b3="BRA-RIV4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="230 KV" b3="2344GCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100968</SeqNum>
    <Name>L230.BrandonShores-Riverside.2345</Name>
    <LastEdit Timestamp="2026-01-07T10:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="23450CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="2345_S6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRANDONS" b2="230 KV" b3="BRA-RIV5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSID" b2="230 KV" b3="2345OCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100969</SeqNum>
    <Name>L115.Burton-LongCreek.27 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-05-23T14:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LONGCREK" b2="115 KV" b3="27D" />
      <ContingencyEquipment Action="X" Type="XF" b1="BAYSIDE" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BAYSIDE" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BAYSIDE" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BAYSIDE" b2="13 KV" b3="TX3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAYSIDE" b2="115 KV" b3="27A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURTON" b2="115 KV" b3="27T166" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BURTON" b2="115 KV" b3="27T181" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONGCREK" b2="115 KV" b3="2769M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100970</SeqNum>
    <Name>L115.LongCreek-VirginiaBeach.27 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-05-27T17:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAINSTOR" b2="115 KV" b3="27E" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAINSTOR" b2="115 KV" b3="27F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAINSTOR" b2="115 KV" b3="H122" />
      <ContingencyEquipment Action="X" Type="XF" b1="BAINSTOR" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BAINSTOR" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONGCREK" b2="115 KV" b3="2766M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="115 KV" b3="2772" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100972</SeqNum>
    <Name>L230.EvergreenMills-YarleyRidge.2209</Name>
    <LastEdit Timestamp="2025-05-23T14:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EVRGREEN" b2="230 KV" b3="220932" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVRGREEN" b2="230 KV" b3="H1T2209" />
      <ContingencyEquipment Action="L" Type="LN" b1="EVRGREEN" b2="230 KV" b3="EVR-YARD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YARDRIDG" b2="230 KV" b3="WT2209" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YARDRIDG" b2="230 KV" b3="XT2209" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100973</SeqNum>
    <Name>L230.EvergreenMills-Brableton.2172</Name>
    <LastEdit Timestamp="2025-12-10T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="217202" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="21722183" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRAMBLET" b2="230 KV" b3="BRA-EVRG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVRGREEN" b2="230 KV" b3="217232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVRGREEN" b2="230 KV" b3="H2T2172" />
      <ContingencyEquipment Action="S" Type="SD" b1="EVRGREEN" b2="230 KV" b3="REAC1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100974</SeqNum>
    <Name>L345.Cook-Thomson.1</Name>
    <LastEdit Timestamp="2025-06-26T11:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COOK" b2="345 KV" b3="COO-THO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOK" b2="345 KV" b3="K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOMSON" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOMSON" b2="345 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100975</SeqNum>
    <Name>L345.Thomson-KenzieCreek</Name>
    <LastEdit Timestamp="2025-05-23T14:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENZIECR" b2="345 KV" b3="KEN-THOM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOMSON" b2="345 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOMSON" b2="345 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100976</SeqNum>
    <Name>L138.Morse-SpringRoad-Genoa</Name>
    <LastEdit Timestamp="2025-07-10T10:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GENOA" b2="138 KV" b3="102C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GENOA" b2="138 KV" b3="102S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORSE" b2="138 KV" b3="MOR-SPRN" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPRNGRD1" b2="138 KV" b3="SPR-GEN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRNGRD1" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRNGRD1" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100977</SeqNum>
    <Name>L138.Morse-Karl</Name>
    <LastEdit Timestamp="2025-07-10T10:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KARL" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KARL" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="KARL" b2="138 KV" b3="KAR-MOR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100978</SeqNum>
    <Name>L138.Hutching-Gebhart</Name>
    <LastEdit Timestamp="2025-05-27T17:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GEBHART" b2="138 KV" b3="RA-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEBHART" b2="138 KV" b3="RA-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="138 KV" b3="AA-G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUTCHING" b2="138 KV" b3="AA-H" />
      <ContingencyEquipment Action="L" Type="LN" b1="GEBHART" b2="138 KV" b3="GEB-HUTC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100979</SeqNum>
    <Name>L138.Gebhart-Sugarcreek</Name>
    <LastEdit Timestamp="2025-05-27T17:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GEBHART" b2="138 KV" b3="GEB-SUGA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEBHART" b2="138 KV" b3="RA-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEBHART" b2="138 KV" b3="RA-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="138 KV" b3="RS-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="138 KV" b3="RS-G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100980</SeqNum>
    <Name>L138.ElkGrove-Schaumburg-RollingMeadows.18410</Name>
    <LastEdit Timestamp="2025-05-29T15:27:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="18410" b2="138 KV" b3="18410 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="22-23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="23-24" />
      <ContingencyEquipment Action="L" Type="LN" b1="18410" b2="138 KV" b3="18410 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="18410" b2="138 KV" b3="18410 3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="206 ROLL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="206 ROLL" b2="138 KV" b3="L18410CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="253 SCHA" b2="138 KV" b3="18410CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100981</SeqNum>
    <Name>L138.ElkGrove-Landmeir-Tonne-E552.18408</Name>
    <LastEdit Timestamp="2026-02-06T12:29:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="15-20" />
      <ContingencyEquipment Action="L" Type="LN" b1="18408" b2="138 KV" b3="18408 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="19-20" />
      <ContingencyEquipment Action="L" Type="LN" b1="18408" b2="138 KV" b3="18408 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="18408" b2="138 KV" b3="18408 3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="207 TONN" b2="138 KV" b3="L18408CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="225 LAND" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E552" b2="138 KV" b3="1-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="18408" b2="138 KV" b3="18408_5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E552" b2="138 KV" b3="2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100982</SeqNum>
    <Name>L138.DesPlains-Busse-ElkGrove.4606</Name>
    <LastEdit Timestamp="2026-03-27T10:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="152 BUSS" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="152 BUSS" b2="138 KV" b3="L4606 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="16-17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="17-18" />
      <ContingencyEquipment Action="L" Type="LN" b1="4606" b2="138 KV" b3="4606-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L4606 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="46 DESPL" b2="138 KV" b3="4606 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="4606" b2="138 KV" b3="4606-BUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100983</SeqNum>
    <Name>500/138.Yukon.TR7</Name>
    <LastEdit Timestamp="2025-08-25T11:29:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="500 KV" b3="B101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="500 KV" b3="B180" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="X" Type="XF" b1="YUKON" b2="500 KV" b3="TR7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100984</SeqNum>
    <Name>230/69.Berks.T3</Name>
    <LastEdit Timestamp="2025-05-23T13:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BERKS" b2="230 KV" b3="TRAN3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKS" b2="230 KV" b3="TRAN3HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKS" b2="69 KV" b3="TRAN3LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100985</SeqNum>
    <Name>L230.Hopewell-WardsCreek.2215</Name>
    <LastEdit Timestamp="2025-10-22T14:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="20412215" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="221532" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPEWEL4" b2="230 KV" b3="HOP-WARD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARDSCRK" b2="230 KV" b3="221552" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARDSCRK" b2="230 KV" b3="240T2215" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100986</SeqNum>
    <Name>L230.Surry-WardsCreek.240</Name>
    <LastEdit Timestamp="2025-05-27T17:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="24002" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SURRY4" b2="230 KV" b3="G1T240" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARDSCRK" b2="230 KV" b3="24052" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARDSCRK" b2="230 KV" b3="240T2215" />
      <ContingencyEquipment Action="L" Type="LN" b1="SURRY4" b2="230 KV" b3="SUR-WARD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100988</SeqNum>
    <Name>L115.HarmonyV-GreysPoint-Rappahanock.1021</Name>
    <LastEdit Timestamp="2025-07-14T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GREYSPT" b2="115 KV" b3="GRE-HARM" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREYSPT" b2="115 KV" b3="GRE-RAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREYSPT" b2="115 KV" b3="GRE-RAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONYV" b2="115 KV" b3="102162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPPAHAN" b2="115 KV" b3="65T1021" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RAPPAHAN" b2="115 KV" b3="SR1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RAPPAHAN" b2="115 KV" b3="SR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100989</SeqNum>
    <Name>138/69/34.Fieldale.T3 </Name>
    <LastEdit Timestamp="2025-07-10T10:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FIELDALE" b2="138 KV" b3="3-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="FIELDALE" b2="69 KV" b3="3-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="FIELDALE" b2="34 KV" b3="3-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDALE" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDALE" b2="34 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIELDALE" b2="138 KV" b3="N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100990</SeqNum>
    <Name>138/69.SugarCreek.BK7</Name>
    <LastEdit Timestamp="2025-05-23T13:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="SUGARCRE" b2="138 KV" b3="138C" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUGARCRE" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="138 KV" b3="RS-138C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="69 KV" b3="RS-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="69 KV" b3="RS-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="138 KV" b3="RS-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUGARCRE" b2="138 KV" b3="RS-K" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100991</SeqNum>
    <Name>L69.Gretna-TaylorMills.1040</Name>
    <LastEdit Timestamp="2025-07-25T16:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRETNA" b2="69 KV" b3="35T1040" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRETNA" b2="69 KV" b3="GRE-GRDP" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GRETNA" b2="69 KV" b3="SC2" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRETNA" b2="69 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRETNADP" b2="69 KV" b3="GRE-TAYM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRETNADP" b2="69 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAYLRMIL" b2="69 KV" b3="104032" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAYLRMIL" b2="69 KV" b3="173T1040" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100992</SeqNum>
    <Name>L69.TaylorMills-Chatham-Climax-Bearskin.173</Name>
    <LastEdit Timestamp="2025-05-23T14:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARSKI4" b2="69 KV" b3="17302" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEARSKI4" b2="138 KV" b3="TX1" />
      <ContingencyEquipment Action="S" Type="SD" b1="CHATHAM4" b2="69 KV" b3="173B1" />
      <ContingencyEquipment Action="S" Type="SD" b1="CHATHAM4" b2="69 KV" b3="173E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHATHAM4" b2="69 KV" b3="SHEVADP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHATHAM4" b2="69 KV" b3="SHOCKODP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHATHAM4" b2="69 KV" b3="TX1 LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEARSKI4" b2="69 KV" b3="173A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLIMAXDP" b2="69 KV" b3="173B" />
      <ContingencyEquipment Action="S" Type="SD" b1="CLIMAXDP" b2="69 KV" b3="173B1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLIMAXDP" b2="69 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAYLRMIL" b2="69 KV" b3="17332" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAYLRMIL" b2="69 KV" b3="173T1040" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHATHAM4" b2="69 KV" b3="CHA-TAYM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100993</SeqNum>
    <Name>DTX138.Dixie.TR7</Name>
    <LastEdit Timestamp="2025-07-11T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DIXIEFE" b2="138 KV" b3="B13294" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DIXIEFE" b2="138 KV" b3="B46" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DIXIEFE" b2="138 KV" b3="TR7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100994</SeqNum>
    <Name>138/69.Turner.TR1</Name>
    <LastEdit Timestamp="2025-05-23T13:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROSSLAN" b2="69 KV" b3="CRO-TURN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="X" Type="XF" b1="TURNER" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100995</SeqNum>
    <Name>DTX138.Turner.T6</Name>
    <LastEdit Timestamp="2025-07-11T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="F2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TURNER" b2="138 KV" b3="T6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100996</SeqNum>
    <Name>Chickahominy.SP</Name>
    <LastEdit Timestamp="2025-05-23T13:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="223322-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="230 KV" b3="223322-3" />
      <ContingencyEquipment Action="S" Type="SD" b1="CHICKHOM" b2="230 KV" b3="2233A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHICKHOM" b2="34.5 KV" b3="CHICK1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHICKHOM" b2="34.5 KV" b3="CHICK1SP" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHICKHOM" b2="230 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100997</SeqNum>
    <Name>L138.Darrow-Terex</Name>
    <LastEdit Timestamp="2025-07-31T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02TEREX" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARROW" b2="138 KV" b3="B113" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARROW" b2="138 KV" b3="B114" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARROW" b2="138 KV" b3="DAR-02T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100998</SeqNum>
    <Name>L115.Carolina-EatonsFerry-HawTree.1044</Name>
    <LastEdit Timestamp="2025-07-25T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAROLINA" b2="115 KV" b3="104402" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CAROLINA" b2="115 KV" b3="104408" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAROLINA" b2="115 KV" b3="CAR-ETNF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ETNFERDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ETNFERDP" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAWTREE" b2="115 KV" b3="104412" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAWTREE" b2="115 KV" b3="22T1044" />
      <ContingencyEquipment Action="L" Type="LN" b1="ETNFERDP" b2="115 KV" b3="ETN-HAWT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>100999</SeqNum>
    <Name>L115.HawTree-KerrDam.22</Name>
    <LastEdit Timestamp="2025-07-07T09:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAWTREE" b2="115 KV" b3="2212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAWTREE" b2="115 KV" b3="22T1044" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="45" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAWTREE" b2="115 KV" b3="HAW-KERR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101000</SeqNum>
    <Name>L345.Baldwin-RushIsland</Name>
    <LastEdit Timestamp="2025-05-27T17:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BALDWIN3" b2="345 KV" b3="4548 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BALDWIN3" b2="345 KV" b3="4552" />
      <ContingencyEquipment Action="L" Type="LN" b1="BALDWIN3" b2="345 KV" b3="BAL-RUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSH   3" b2="345 KV" b3="BLWN4585" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101001</SeqNum>
    <Name>138/23.England.TXB</Name>
    <LastEdit Timestamp="2025-05-27T17:57:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-N" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ENGLAND" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="23 KV" b3="R" />
      <ContingencyEquipment Action="X" Type="XF" b1="ENGLAND" b2="138 KV" b3="TRAN B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101002</SeqNum>
    <Name>138/23.England.TXA</Name>
    <LastEdit Timestamp="2025-05-27T18:00:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-I" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-L" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ENGLAND" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="23 KV" b3="O" />
      <ContingencyEquipment Action="X" Type="XF" b1="ENGLAND" b2="138 KV" b3="TRAN A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101003</SeqNum>
    <Name>L345.Mrgnvly-Arnold</Name>
    <LastEdit Timestamp="2025-05-27T17:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARNOLD16" b2="345 KV" b3="0710" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARNOLD16" b2="345 KV" b3="2820" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARNOLD16" b2="345 KV" b3="ARN-MRGN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MRGNVLY" b2="345 KV" b3="6954" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MRGNVLY" b2="345 KV" b3="6955" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101004</SeqNum>
    <Name>L345.Mrgnvly-Beverly &amp; 345/161.Beverly.TR7</Name>
    <LastEdit Timestamp="2025-05-29T15:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEVERLY6" b2="345 KV" b3="7233" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEVERLY6" b2="345 KV" b3="BEV-MRGN" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEVERLY6" b2="345 KV" b3="TR7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MRGNVLY" b2="345 KV" b3="6955" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MRGNVLY" b2="345 KV" b3="6956" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101008</SeqNum>
    <Name>DTX230.CabinRun.LD2</Name>
    <LastEdit Timestamp="2025-10-02T10:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINRUN" b2="230 KV" b3="221312" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CABINRUN" b2="230 KV" b3="LD2_LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINRUN" b2="230 KV" b3="T122" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101009</SeqNum>
    <Name>DTX230.CabinRun.LD1</Name>
    <LastEdit Timestamp="2026-03-31T10:23:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINRUN" b2="230 KV" b3="228712" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CABINRUN" b2="230 KV" b3="LD1_LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINRUN" b2="230 KV" b3="T122" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101019</SeqNum>
    <Name>DTX69.Quinton.T2</Name>
    <LastEdit Timestamp="2021-04-23T11:55:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINTON" b2="69 KV" b3="N" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="QUINTON" b2="69 KV" b3="T2_LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="QUINTON" b2="69 KV" b3="T2_LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101020</SeqNum>
    <Name>DTX69.RioGrande.T7</Name>
    <LastEdit Timestamp="2025-07-02T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIOGRAND" b2="69 KV" b3="BV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIOGRAND" b2="69 KV" b3="T7" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="RIOGRAND" b2="69 KV" b3="T7" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="RIOGRAND" b2="69 KV" b3="T7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIOGRAND" b2="69 KV" b3="U" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101021</SeqNum>
    <Name>DTX69.RioGrande.T6</Name>
    <LastEdit Timestamp="2025-07-03T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIOGRAND" b2="69 KV" b3="R" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIOGRAND" b2="69 KV" b3="T6" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="RIOGRAND" b2="69 KV" b3="T6" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="RIOGRAND" b2="69 KV" b3="T6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIOGRAND" b2="69 KV" b3="V CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101022</SeqNum>
    <Name>DTX69.RioGrande.T8</Name>
    <LastEdit Timestamp="2025-07-03T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIOGRAND" b2="69 KV" b3="AW" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIOGRAND" b2="69 KV" b3="T8" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="RIOGRAND" b2="69 KV" b3="T8" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="RIOGRAND" b2="69 KV" b3="T8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIOGRAND" b2="69 KV" b3="W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101024</SeqNum>
    <Name>DTX69.RoadsTown.Load1</Name>
    <LastEdit Timestamp="2025-07-03T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROADSTOW" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROADSTOW" b2="69 KV" b3="LOADDIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101025</SeqNum>
    <Name>DTX69.RoadsTown.T2Load</Name>
    <LastEdit Timestamp="2025-07-02T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROADSTOW" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROADSTOW" b2="69 KV" b3="T2LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101026</SeqNum>
    <Name>DTX69.Rowan.RowanT1</Name>
    <LastEdit Timestamp="2025-07-02T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROWAN" b2="69 KV" b3="GCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROWAN" b2="69 KV" b3="GCB D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROWAN" b2="69 KV" b3="ROWANT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101027</SeqNum>
    <Name>DTX69.Rowan.RowanT2</Name>
    <LastEdit Timestamp="2025-07-02T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROWAN" b2="69 KV" b3="GCB B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROWAN" b2="69 KV" b3="GCB C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROWAN" b2="69 KV" b3="ROWANT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101028</SeqNum>
    <Name>DTX138.Scull.Bus1</Name>
    <LastEdit Timestamp="2021-04-23T11:54:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCULL" b2="138 KV" b3="BUS1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SCULL" b2="138 KV" b3="BUS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCULL" b2="138 KV" b3="CS A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101029</SeqNum>
    <Name>DTX138.Scull.Bus2</Name>
    <LastEdit Timestamp="2021-04-23T11:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCULL" b2="138 KV" b3="BUS2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SCULL" b2="138 KV" b3="BUS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCULL" b2="138 KV" b3="CS B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101030</SeqNum>
    <Name>DTX69.SeaIsle.T1Load</Name>
    <LastEdit Timestamp="2021-04-23T11:52:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEAISLE" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEAISLE" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SEAISLE" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SEAISLE" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101031</SeqNum>
    <Name>DTX69.SeaIsle.T2Load</Name>
    <LastEdit Timestamp="2021-04-23T11:52:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEAISLE" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEAISLE" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SEAISLE" b2="69 KV" b3="T2 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SEAISLE" b2="69 KV" b3="T2 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101032</SeqNum>
    <Name>DTX69.SearsTown.Load2</Name>
    <LastEdit Timestamp="2025-09-09T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="SEARSTOW" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SEARSTOW" b2="69 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEARSTOW" b2="69 KV" b3="CB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEARSTOW" b2="69 KV" b3="CB AW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEARSTOW" b2="69 KV" b3="CB R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEARSTOW" b2="69 KV" b3="GEN CB" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SEARSTOW" b2="69 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101033</SeqNum>
    <Name>DTX69.SearsTown.Load1</Name>
    <LastEdit Timestamp="2025-09-09T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEARSTOW" b2="69 KV" b3="CB AW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEARSTOW" b2="69 KV" b3="CB B" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SEARSTOW" b2="69 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101034</SeqNum>
    <Name>DTX69.SecondStreet.Wheat2</Name>
    <LastEdit Timestamp="2024-11-13T14:25:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SECONDST" b2="69 KV" b3="J_CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SECONDST" b2="69 KV" b3="WHEAT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101037</SeqNum>
    <Name>DTX69.SecondStreet.Load2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-02T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SECONDST" b2="69 KV" b3="LOAD2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SECONDST" b2="69 KV" b3="N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101038</SeqNum>
    <Name>DTX69.SecondStreet.Wheat1</Name>
    <LastEdit Timestamp="2021-04-23T11:53:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SECONDST" b2="69 KV" b3="DIS M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SECONDST" b2="69 KV" b3="WHEAT1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SECONDST" b2="69 KV" b3="WHEAT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101039</SeqNum>
    <Name>DTX69.SecondStreet.Load1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-02T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SECONDST" b2="69 KV" b3="DIS O" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SECONDST" b2="69 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101041</SeqNum>
    <Name>DTX69.ShipBottom.T1 </Name>
    <LastEdit Timestamp="2021-04-23T11:50:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHIPBOTT" b2="69 KV" b3="GCB B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHIPBOTT" b2="69 KV" b3="GCB C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHIPBOTT" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SHIPBOTT" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101042</SeqNum>
    <Name>DTX69.ShipBottom.T2</Name>
    <LastEdit Timestamp="2021-04-23T11:50:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHIPBOTT" b2="69 KV" b3="GCB E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHIPBOTT" b2="69 KV" b3="GCB F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHIPBOTT" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SHIPBOTT" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101043</SeqNum>
    <Name>DTX69.Sickler.T3Load</Name>
    <LastEdit Timestamp="2021-04-23T11:50:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SICKLER" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SICKLER" b2="69 KV" b3="T3LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SICKLER" b2="69 KV" b3="T3LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101044</SeqNum>
    <Name>DTX69.Sickler.2BUS</Name>
    <LastEdit Timestamp="2021-04-23T11:50:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SICKLER" b2="69 KV" b3="2BUS" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="SICKLER" b2="69 KV" b3="2BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SICKLER" b2="69 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101045</SeqNum>
    <Name>DTX69.SilverLake.Bus5</Name>
    <LastEdit Timestamp="2025-07-02T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SILVERLA" b2="69 KV" b3="BUS5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERLA" b2="69 KV" b3="Q" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101048</SeqNum>
    <Name>DTX69.SouthMillVille.Load2</Name>
    <LastEdit Timestamp="2025-07-02T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SMILLVIL" b2="69 KV" b3="LOAD2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMILLVIL" b2="69 KV" b3="LOAD2DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101049</SeqNum>
    <Name>DTX69.SouthMillVille.Load1</Name>
    <LastEdit Timestamp="2025-07-02T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMILLVIL" b2="69 KV" b3="F DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SMILLVIL" b2="69 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101050</SeqNum>
    <Name>DTX69.Stratford.T1</Name>
    <LastEdit Timestamp="2025-12-01T13:35:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STRATFOR" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRATFOR" b2="69 KV" b3="CB_B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STRATFOR" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101051</SeqNum>
    <Name>DTX69.StratFord.T2</Name>
    <LastEdit Timestamp="2026-01-27T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STRATFOR" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRATFOR" b2="69 KV" b3="CB_B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STRATFOR" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101052</SeqNum>
    <Name>DTX69.SWainton.Load2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-06-27T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="SWAINTON" b2="69 KV" b3="DIS C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWAINTON" b2="69 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101054</SeqNum>
    <Name>DTX69.Tabernacle.T2</Name>
    <LastEdit Timestamp="2025-06-27T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TABERNAC" b2="69 KV" b3="OCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TABERNAC" b2="69 KV" b3="R" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TABERNAC" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101055</SeqNum>
    <Name>DTX69.Tabernacle.T1</Name>
    <LastEdit Timestamp="2025-06-27T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="TABERNAC" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="TABERNAC" b2="69 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TABERNAC" b2="69 KV" b3="CB G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TABERNAC" b2="69 KV" b3="OCB B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TABERNAC" b2="69 KV" b3="R" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TABERNAC" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101056</SeqNum>
    <Name>DTX69.Tansboro.T1Load</Name>
    <LastEdit Timestamp="2021-04-23T11:30:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TANSBORO" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANSBORO" b2="69 KV" b3="F CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TANSBORO" b2="69 KV" b3="T1 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="TANSBORO" b2="69 KV" b3="T1 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101057</SeqNum>
    <Name>DTX69.Tansboro.T2Load</Name>
    <LastEdit Timestamp="2021-04-23T11:30:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TANSBORO" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANSBORO" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TANSBORO" b2="69 KV" b3="T2 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="TANSBORO" b2="69 KV" b3="T2 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101058</SeqNum>
    <Name>DTX69.Tansboro.JMLoad</Name>
    <LastEdit Timestamp="2025-06-27T09:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TANSBORO" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANSBORO" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TANSBORO" b2="69 KV" b3="JM LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101059</SeqNum>
    <Name>DTX69.Terrace.Bus1</Name>
    <LastEdit Timestamp="2025-06-27T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TERRACE" b2="69 KV" b3="BUS1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TERRACE" b2="69 KV" b3="C DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101060</SeqNum>
    <Name>DTX69.Terrace.Bus3</Name>
    <LastEdit Timestamp="2025-06-27T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TERRACE" b2="69 KV" b3="BUS3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TERRACE" b2="69 KV" b3="P DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101061</SeqNum>
    <Name>DTX69.Tuckahoe.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-06-27T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TUCKAHOE" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TUCKAHOE" b2="69 KV" b3="T1 DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101063</SeqNum>
    <Name>DTX138.UpperPittsGrove.LOAD (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-01T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="UPPERPIT" b2="138 KV" b3="DIS  D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERPIT" b2="138 KV" b3="GENCB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UPPERPIT" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="UPPERPIT" b2="138 KV" b3="PITSGVSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101065</SeqNum>
    <Name>DTX69.Washington.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2021-04-23T11:32:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="WASHINGT" b2="69 KV" b3="I" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WASHINGT" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="WASHINGT" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101068</SeqNum>
    <Name>DTX69.Washington.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2021-04-23T11:32:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="WASHINGT" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WASHINGT" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="WASHINGT" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101069</SeqNum>
    <Name>DTX69.Winslow.T1</Name>
    <LastEdit Timestamp="2025-06-27T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="WINSLOW" b2="69 KV" b3="R" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WINSLOW" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101070</SeqNum>
    <Name>DTX69.Winslow.T2</Name>
    <LastEdit Timestamp="2025-06-27T13:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="WINSLOW" b2="69 KV" b3="S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WINSLOW" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101071</SeqNum>
    <Name>DTX69.WoodsTown.LoadT4</Name>
    <LastEdit Timestamp="2025-06-27T12:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSTOW" b2="69 KV" b3="GENCB1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODSTOW" b2="69 KV" b3="LOAD_T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSTOW" b2="69 KV" b3="OCB A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODSTOW" b2="69 KV" b3="PLGRV1SP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101072</SeqNum>
    <Name>DTX69.WoodsTown.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-06-27T12:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODSTOW" b2="69 KV" b3="GENCB2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WOODSTOW" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODSTOW" b2="69 KV" b3="LOAD_T3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WOODSTOW" b2="69 KV" b3="PLGRV2SP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101075</SeqNum>
    <Name>DTX69.Glassboro.BUS2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-06-27T09:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLASSBOR" b2="69 KV" b3="BUS2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GLASSBOR" b2="69 KV" b3="I" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101076</SeqNum>
    <Name>DTX69.Glassboro.BUS3 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-02T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLASSBOR" b2="69 KV" b3="BUS3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GLASSBOR" b2="69 KV" b3="M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101077</SeqNum>
    <Name>DTX69.Glassboro.BUS5 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-02T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLASSBOR" b2="69 KV" b3="BUS5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GLASSBOR" b2="69 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101078</SeqNum>
    <Name>69/23.Higbee.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2023-09-13T14:09:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="HIGBEE" b2="23 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGBEE" b2="23 KV" b3="D20" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="HIGBEE" b2="23 KV" b3="LOAD_2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIGBEE" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HIGBEE" b2="69 KV" b3="T2HS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101080</SeqNum>
    <Name>69/23.Higbee.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2023-09-13T14:12:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="HIGBEE" b2="23 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGBEE" b2="23 KV" b3="D1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="HIGBEE" b2="23 KV" b3="LOAD_1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HIGBEE" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HIGBEE" b2="69 KV" b3="T1HS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101082</SeqNum>
    <Name>DTX69.HighStreet.T1</Name>
    <LastEdit Timestamp="2025-07-02T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHST" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHST" b2="69 KV" b3="N" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIGHST" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101083</SeqNum>
    <Name>DTX69.Huron.LoadTr2</Name>
    <LastEdit Timestamp="2025-07-02T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HURON" b2="69 KV" b3="LOADTR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HURON" b2="69 KV" b3="V CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HURON" b2="69 KV" b3="W CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101084</SeqNum>
    <Name>DTX69.Huron.LoadTr1</Name>
    <LastEdit Timestamp="2025-07-02T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HURON" b2="69 KV" b3="K CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HURON" b2="69 KV" b3="LOADTR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HURON" b2="69 KV" b3="M CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101085</SeqNum>
    <Name>DTX69.LakeAvenue.T8</Name>
    <LastEdit Timestamp="2025-09-09T11:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVEN" b2="69 KV" b3="AW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVEN" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAKEAVEN" b2="69 KV" b3="T8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101086</SeqNum>
    <Name>DTX69.LakeAvenue.T9</Name>
    <LastEdit Timestamp="2021-04-23T11:48:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVEN" b2="69 KV" b3="DE_" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKEAVEN" b2="69 KV" b3="N_" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAKEAVEN" b2="69 KV" b3="T9" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="LAKEAVEN" b2="69 KV" b3="T9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101087</SeqNum>
    <Name>DTX69.Dacosta.Load2</Name>
    <LastEdit Timestamp="2025-07-02T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DACOSTA" b2="69 KV" b3="LOAD2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DACOSTA" b2="69 KV" b3="LOAD2DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101088</SeqNum>
    <Name>DTX69.Dacosta.Load1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="DACOSTA" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DACOSTA" b2="69 KV" b3="GCB O" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DACOSTA" b2="69 KV" b3="LOAD DIS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DACOSTA" b2="69 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101090</SeqNum>
    <Name>DTX138.Dorothy.Bus1 </Name>
    <LastEdit Timestamp="2025-07-02T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOROTHY" b2="138 KV" b3="1BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOROTHY" b2="138 KV" b3="N CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOROTHY" b2="138 KV" b3="P CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101091</SeqNum>
    <Name>DTX138.Dorothy.Bus2</Name>
    <LastEdit Timestamp="2025-07-02T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOROTHY" b2="138 KV" b3="2BUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOROTHY" b2="138 KV" b3="Q CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOROTHY" b2="138 KV" b3="R CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101092</SeqNum>
    <Name>DTX138.Franklin.T1</Name>
    <LastEdit Timestamp="2025-07-02T09:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKAE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKAE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRANKAE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101093</SeqNum>
    <Name>L69.Tuckahoe-Mill</Name>
    <LastEdit Timestamp="2025-06-04T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILL" b2="69 KV" b3="OCB N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUCKAHOE" b2="69 KV" b3="GCB E" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILL" b2="69 KV" b3="MIL-TUC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101094</SeqNum>
    <Name>L138.469EverGreenPark-814Damen.81414</Name>
    <LastEdit Timestamp="2025-06-19T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="469 EVRG" b2="138 KV" b3="81414" />
      <ContingencyEquipment Action="OP" Type="CB" b1="469 EVRG" b2="138 KV" b3="L81414CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="814 DAME" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="814 DAME" b2="138 KV" b3="L81414CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101095</SeqNum>
    <Name>L115.Tarboro-ShilohDP-ConetoeDP-BethelCarolina.105</Name>
    <LastEdit Timestamp="2025-09-18T15:54:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BETHELCA" b2="115 KV" b3="105A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONETODP" b2="115 KV" b3="105B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHELCA" b2="115 KV" b3="H142" />
      <ContingencyEquipment Action="X" Type="XF" b1="BETHELCA" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETHELCA" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CONETODP" b2="115 KV" b3="105C1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONETODP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHILOHDP" b2="115 KV" b3="105D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHILOHDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TARBORO" b2="115 KV" b3="55T105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TARBORO" b2="115 KV" b3="L4T105" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101096</SeqNum>
    <Name>L115.Everetts-WilRobDP-Robersonvil-MrtnDP-Parme.96</Name>
    <LastEdit Timestamp="2025-09-18T15:54:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EVERETTS" b2="115 KV" b3="9612" />
      <ContingencyEquipment Action="L" Type="LN" b1="WILROBDP" b2="115 KV" b3="96D" />
      <ContingencyEquipment Action="L" Type="LN" b1="MRTNCTDP" b2="115 KV" b3="96A" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROBERSNV" b2="115 KV" b3="96F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MRTNCTDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PARMELE" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PARMELE" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROBERSNV" b2="115 KV" b3="96C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROBERSNV" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILROBDP" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101097</SeqNum>
    <Name>230/115.Tarboro.TX4</Name>
    <LastEdit Timestamp="2025-06-23T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TARBORO" b2="230 KV" b3="H472" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TARBORO" b2="115 KV" b3="L4T105" />
      <ContingencyEquipment Action="X" Type="XF" b1="TARBORO" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101098</SeqNum>
    <Name>230/115.Tarboro.TX3</Name>
    <LastEdit Timestamp="2025-06-23T12:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TARBORO" b2="230 KV" b3="H372" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TARBORO" b2="115 KV" b3="L3T55" />
      <ContingencyEquipment Action="X" Type="XF" b1="TARBORO" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101099</SeqNum>
    <Name>345/138.Chamberlin.T4 </Name>
    <LastEdit Timestamp="2025-07-11T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="345 KV" b3="B210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="138 KV" b3="B56" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAMBROE" b2="345 KV" b3="B89" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHAMBROE" b2="345 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101100</SeqNum>
    <Name>138/34.Martinsville.T3</Name>
    <LastEdit Timestamp="2025-07-07T09:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MARTINSV" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARTINSV" b2="34 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSV" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101103</SeqNum>
    <Name>138/69.Darrow.TR1</Name>
    <LastEdit Timestamp="2025-08-13T13:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARROW" b2="138 KV" b3="B116" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARROW" b2="138 KV" b3="B117" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARROW" b2="69 KV" b3="B31" />
      <ContingencyEquipment Action="X" Type="XF" b1="DARROW" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101104</SeqNum>
    <Name>L345.EastElkhart-Thomson</Name>
    <LastEdit Timestamp="2025-06-26T11:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="345 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOMSON" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOMSON" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EELKHART" b2="345 KV" b3="EEL-THOM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101105</SeqNum>
    <Name>L345.IndeckNiles-Thomson + IndeckNiles.CC</Name>
    <LastEdit Timestamp="2026-02-10T09:42:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="INDECK" b2="345 KV" b3="1A_GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDECK" b2="345 KV" b3="1B_GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="INDECK" b2="345 KV" b3="1S_GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDECK" b2="345 KV" b3="1Z" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INDECK" b2="26 KV" b3="AUX1LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INDECK" b2="26 KV" b3="AUX2LD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="INDECK" b2="26 KV" b3="CTG1A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="INDECK" b2="26 KV" b3="CTG1B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="INDECK" b2="24 KV" b3="STG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOMSON" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THOMSON" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="INDECK" b2="345 KV" b3="IND-THOM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101108</SeqNum>
    <Name>115/13.Mainpost.TX2</Name>
    <LastEdit Timestamp="2025-06-26T11:44:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAINPOST" b2="115 KV" b3="H202" />
      <ContingencyEquipment Action="X" Type="XF" b1="MAINPOST" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAINPOST" b2="13.2 KV" b3="TX2LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101110</SeqNum>
    <Name>L69.Corey-Ripple</Name>
    <LastEdit Timestamp="2025-06-26T11:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COREY" b2="69 KV" b3="A CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="COREY" b2="69 KV" b3="COR-RIPP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIPPLE" b2="69 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101111</SeqNum>
    <Name>L345/DC/230.Bergen-HudsonConverter-West49th.Y56</Name>
    <LastEdit Timestamp="2024-08-16T10:49:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="23-24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="6-24" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERGEN" b2="230 KV" b3="BER-HUD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HCS" b2="500 KV" b3="NYPUMP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HCSNY" b2="345 KV" b3="20D01CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HCSNY" b2="345 KV" b3="20D03CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HCSNY" b2="345 KV" b3="20D04CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HCSNY" b2="345 KV" b3="20D05CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HCSNY" b2="345 KV" b3="20D06CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HCSNY" b2="345 KV" b3="HCS-W49S" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HCSNY" b2="500 KV" b3="PJMGEN" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="W49ST" b2="138 KV" b3="38M42" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="W49ST" b2="138 KV" b3="38M72_65" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W49ST" b2="345 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W49ST" b2="345 KV" b3="8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101112</SeqNum>
    <Name>L138.187SchauffR-155Nelson.15515</Name>
    <LastEdit Timestamp="2025-07-11T13:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="155 NELS" b2="138 KV" b3="L15515CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="187 SCHA" b2="138 KV" b3="10-12" />
      <ContingencyEquipment Action="L" Type="LN" b1="155 NELS" b2="138 KV" b3="15515 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="187 SCHA" b2="138 KV" b3="7-12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101116</SeqNum>
    <Name>Springdale.CC</Name>
    <LastEdit Timestamp="2025-07-07T10:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SPRINGDA" b2="138 KV" b3="CT-3" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPRINGDA" b2="138 KV" b3="CT-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="CT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPRINGDA" b2="18 KV" b3="CT3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRINGDA" b2="18 KV" b3="CT3 AUX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="CT4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPRINGDA" b2="18 KV" b3="CT4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRINGDA" b2="18 KV" b3="CT4 AUX" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPRINGDA" b2="138 KV" b3="ST-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="ST5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SPRINGDA" b2="18 KV" b3="ST5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRINGDA" b2="18 KV" b3="ST5 AUX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101119</SeqNum>
    <Name>L345.Elwood-Jackson.1</Name>
    <LastEdit Timestamp="2025-07-07T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT8-12CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="900 ELWO" b2="345 KV" b3="ELW-JAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="929 JACK" b2="345 KV" b3="GSU1CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101120</SeqNum>
    <Name>L345.Elwood-Jackson.2</Name>
    <LastEdit Timestamp="2025-07-07T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="900 ELWO" b2="345 KV" b3="BT5-7 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="900 ELWO" b2="345 KV" b3="ELW-JAC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="929 JACK" b2="345 KV" b3="GSU2CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101121</SeqNum>
    <Name>929_Jackson.CC1</Name>
    <LastEdit Timestamp="2024-12-12T14:10:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="929 JACK" b2="22 KV" b3="AUX1LD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="929 JACK" b2="22 KV" b3="GEN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="929 JACK" b2="22 KV" b3="GEN1CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="929 JACK" b2="345 KV" b3="GSU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="929 JACK" b2="345 KV" b3="GSU1CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101122</SeqNum>
    <Name>929_Jackson.CC2</Name>
    <LastEdit Timestamp="2024-12-12T14:10:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="929 JACK" b2="22 KV" b3="AUX2LD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="929 JACK" b2="22 KV" b3="GEN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="929 JACK" b2="22 KV" b3="GEN2CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="929 JACK" b2="345 KV" b3="GSU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="929 JACK" b2="345 KV" b3="GSU2CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101123</SeqNum>
    <Name>L138.GMLordstown-Magellan</Name>
    <LastEdit Timestamp="2025-07-03T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GMWAROE" b2="138 KV" b3="B67" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGELLAN" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGELLAN" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="L" Type="LN" b1="GMWAROE" b2="138 KV" b3="GMW-MAGE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101124</SeqNum>
    <Name>WardsCreek.SP</Name>
    <LastEdit Timestamp="2025-07-07T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WARDSCRK" b2="230 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARDSCRK" b2="230 KV" b3="GSU_CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WARDSCRK" b2="34.5 KV" b3="WARCRKSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARDSCRK" b2="34.5 KV" b3="WARDCRK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101125</SeqNum>
    <Name>345/138.Bath.BK-N</Name>
    <LastEdit Timestamp="2025-07-22T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BATH" b2="345 KV" b3="BK-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="138 KV" b3="BL-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="345 KV" b3="GL-GG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATH" b2="345 KV" b3="GL-HH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101126</SeqNum>
    <Name>138/69.WestMilton.BK-8</Name>
    <LastEdit Timestamp="2025-10-21T13:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WMILTON" b2="138 KV" b3="BK-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="69 KV" b3="OC-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="69 KV" b3="OC-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="138 KV" b3="OC-H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="138 KV" b3="OC-J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101127</SeqNum>
    <Name>345/138.WestMilton.BK-W </Name>
    <LastEdit Timestamp="2025-07-22T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WMILTON" b2="345 KV" b3="BK-W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="138 KV" b3="OC-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="138 KV" b3="OC-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="345 KV" b3="OC-BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="345 KV" b3="OC-EE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101128</SeqNum>
    <Name>L138.RidgeRoad-Pofolk</Name>
    <LastEdit Timestamp="2025-08-21T12:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_GPFK" b2="138 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_GPFK" b2="138 KV" b3="CB4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CPP_GPFK" b2="138 KV" b3="GPF-RID1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_RIDG" b2="138 KV" b3="RGCB3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CPP_RIDG" b2="138 KV" b3="RGCB4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101129</SeqNum>
    <Name>L138.Amlin-Hayden</Name>
    <LastEdit Timestamp="2025-07-03T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMLIN" b2="138 KV" b3="AML-HAYD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMLIN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMLIN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYDEN" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYDEN" b2="138 KV" b3="G1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101130</SeqNum>
    <Name>L138.Hayden-Cole</Name>
    <LastEdit Timestamp="2025-07-03T15:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLE" b2="138 KV" b3="COL-HAYD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYDEN" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYDEN" b2="138 KV" b3="G2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101131</SeqNum>
    <Name>L138.Boutwell-Elima</Name>
    <LastEdit Timestamp="2025-07-11T13:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOUTWELL" b2="138 KV" b3="BOU-ELIM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOUTWELL" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOUTWELL" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="D1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101132</SeqNum>
    <Name>DTX138.Boutwell.T1</Name>
    <LastEdit Timestamp="2025-08-14T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOUTWELL" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOUTWELL" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOUTWELL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101133</SeqNum>
    <Name>L230.Cumulus-Farmwell.2190</Name>
    <LastEdit Timestamp="2025-07-14T15:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMULUS" b2="230 KV" b3="H12T2190" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMULUS" b2="230 KV" b3="H34T2190" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMWELL" b2="230 KV" b3="219082" />
      <ContingencyEquipment Action="L" Type="LN" b1="CUMULUS" b2="230 KV" b3="CUM-FARM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMWELL" b2="230 KV" b3="WT2190" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101134</SeqNum>
    <Name>L765.Kammer-Guernsey</Name>
    <LastEdit Timestamp="2025-07-16T12:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GUERNSEY" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUERNSEY" b2="765 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="GUERNSEY" b2="765 KV" b3="GUE-KAMM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="765 KV" b3="QQ1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="765 KV" b3="QQ2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="KAMMER2" b2="765 KV" b3="RXCA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="KAMMER2" b2="765 KV" b3="RXCB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="KAMMER2" b2="765 KV" b3="RXCC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101135</SeqNum>
    <Name>L765.Guernsey-Vassell</Name>
    <LastEdit Timestamp="2025-07-15T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GUERNSEY" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUERNSEY" b2="765 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="GUERNSEY" b2="765 KV" b3="GUE-VASS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="765 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VASSELL" b2="765 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101136</SeqNum>
    <Name>Clover.SVC1</Name>
    <LastEdit Timestamp="2025-07-15T12:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="500 KV" b3="BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="500 KV" b3="BUCK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="500 KV" b3="SV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="500 KV" b3="SV112" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101140</SeqNum>
    <Name>L138.DicksCreekGen-ToddHunter</Name>
    <LastEdit Timestamp="2025-07-07T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="D_C_GEN" b2="138 KV" b3="960" />
      <ContingencyEquipment Action="OP" Type="CB" b1="D_C_GEN" b2="138 KV" b3="963" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="937" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODDHUNT" b2="138 KV" b3="939" />
      <ContingencyEquipment Action="L" Type="LN" b1="D_C_GEN" b2="138 KV" b3="DCG-TODD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101141</SeqNum>
    <Name>DicksCreekGen.U1-5</Name>
    <LastEdit Timestamp="2025-07-07T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="D_C_GEN" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="X" Type="XF" b1="D_C_GEN" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="X" Type="XF" b1="D_C_GEN" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="D_C_GEN" b2="138 KV" b3="957" />
      <ContingencyEquipment Action="OP" Type="CB" b1="D_C_GEN" b2="138 KV" b3="963" />
      <ContingencyEquipment Action="U" Type="GEN" b1="D_C_GEN" b2="13 KV" b3="CT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="D_C_GEN" b2="13 KV" b3="CT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="D_C_GEN" b2="13 KV" b3="CT4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="D_C_GEN" b2="13 KV" b3="CT5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101142</SeqNum>
    <Name>230/69.Hillsdale.220-1XF</Name>
    <LastEdit Timestamp="2025-07-07T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="69 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="69 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLSDAL" b2="230 KV" b3="220-1CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="HILLSDAL" b2="230 KV" b3="220-1XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101143</SeqNum>
    <Name>DTX230.EvergreenMills.H137</Name>
    <LastEdit Timestamp="2025-07-07T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EVRGREEN" b2="230 KV" b3="H132" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EVRGREEN" b2="230 KV" b3="H137_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVRGREEN" b2="230 KV" b3="H1T2209" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101144</SeqNum>
    <Name>DTX230.EvergreenMills.H237</Name>
    <LastEdit Timestamp="2025-07-07T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EVRGREEN" b2="230 KV" b3="H232" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EVRGREEN" b2="230 KV" b3="H237_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVRGREEN" b2="230 KV" b3="H2T2172" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101145</SeqNum>
    <Name>DTX69.Washington.T3</Name>
    <LastEdit Timestamp="2021-05-07T13:08:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WASHINGT" b2="69 KV" b3="GCB_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WASHINGT" b2="69 KV" b3="GCB_F" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="WASHINGT" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WASHINGT" b2="69 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101146</SeqNum>
    <Name>138/115.Roxbury.T2</Name>
    <LastEdit Timestamp="2025-08-11T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBURY" b2="115 KV" b3="B31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBURY" b2="115 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBURY" b2="138 KV" b3="B35" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROXBURY" b2="138 KV" b3="NO2 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101148</SeqNum>
    <Name>DTX138.184ElkGrove.MOBILELD.TR78</Name>
    <LastEdit Timestamp="2026-02-25T10:34:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="21-22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="22-23" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="184 ELKG" b2="138 KV" b3="MOBILELD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101149</SeqNum>
    <Name>DTX138.184ElkGrove.TR76</Name>
    <LastEdit Timestamp="2025-07-10T10:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="18-19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="19-20" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="184 ELKG" b2="138 KV" b3="TR76_12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101150</SeqNum>
    <Name>L138.Trabue-Fisher</Name>
    <LastEdit Timestamp="2025-08-19T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FISHER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="FISHER" b2="138 KV" b3="FIS-TRA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FISHER" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRABUE" b2="138 KV" b3="S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101151</SeqNum>
    <Name>L69.Moorepark-WhlrST-DockFoundry-Ripple</Name>
    <LastEdit Timestamp="2025-07-11T13:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DOCKFOUN" b2="69 KV" b3="DOC-RIPP" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOCKFOUN" b2="69 KV" b3="DOC-WHEE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOCKFOUN" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOOREPAR" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOOREPAR" b2="69 KV" b3="MOO-WHEE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIPPLE" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHEELRST" b2="69 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101152</SeqNum>
    <Name>L138.Kammer-Hannibal.4</Name>
    <LastEdit Timestamp="2025-07-10T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNIBAL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNIBAL" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="F CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KAMMER2" b2="138 KV" b3="F2 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANNIBAL" b2="138 KV" b3="HAN-KAM4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101153</SeqNum>
    <Name>DTX138.Magellan.TR3</Name>
    <LastEdit Timestamp="2025-07-11T13:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGELLAN" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGELLAN" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAGELLAN" b2="138 KV" b3="TR3_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101157</SeqNum>
    <Name>L230.Upland-Parrish.220-20</Name>
    <LastEdit Timestamp="2025-07-10T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PARRISH" b2="230 KV" b3="705 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARRISH" b2="230 KV" b3="715 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPLANDPE" b2="230 KV" b3="205_CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="PARRISH" b2="230 KV" b3="PAR-UPLA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101158</SeqNum>
    <Name>230/13.Upland.TR1</Name>
    <LastEdit Timestamp="2025-07-10T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="UPLANDPE" b2="13.8 KV" b3="1TRLS_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPLANDPE" b2="230 KV" b3="715_CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="UPLANDPE" b2="230 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101159</SeqNum>
    <Name>230/13.Upland.TR3</Name>
    <LastEdit Timestamp="2025-07-10T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="UPLANDPE" b2="13.8 KV" b3="3TRLS_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPLANDPE" b2="230 KV" b3="935_CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="UPLANDPE" b2="230 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101160</SeqNum>
    <Name>L138.Saltvill-ElkGard-Lebanon-ClinchRiver</Name>
    <LastEdit Timestamp="2025-08-21T17:10:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLINCHRI" b2="138 KV" b3="CLI-LEB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKGARD2" b2="138 KV" b3="ELK-LEB1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKGARD2" b2="138 KV" b3="ELK-SAL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELKGARD2" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELKGARD2" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELKGARD2" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEBANON" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SALTVILL" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101241</SeqNum>
    <Name>L230.Kearny-NJTMeadows.P-2216</Name>
    <LastEdit Timestamp="2025-07-14T15:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="1-15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEARNY" b2="230 KV" b3="15-16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NJTMEADO" b2="230 KV" b3="2-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NJTMEADO" b2="230 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEARNY" b2="230 KV" b3="KEA-NJT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101243</SeqNum>
    <Name>L69.Frackville-HghRdge-Okhll-Cass-Extrd-Fichbach.3</Name>
    <LastEdit Timestamp="2025-01-15T10:24:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CASS" b2="69 KV" b3="CAS-EXT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CASS" b2="69 KV" b3="CAS-EXT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CASS" b2="69 KV" b3="CAS-OAK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CASS" b2="69 KV" b3="T1LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EXTRUDIO" b2="69 KV" b3="AUB_LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="EXTRUDIO" b2="69 KV" b3="EXT-FISH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EXTRUDIO" b2="69 KV" b3="EXTRLOAD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FISHBACH" b2="69 KV" b3="BT2-3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FISHBACH" b2="69 KV" b3="BUS1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FISHBACH" b2="69 KV" b3="FRACKLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="FISH3" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRACKVIL" b2="69 KV" b3="FRA-HIGH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="MOW2FIS3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HIGHR_PL" b2="69 KV" b3="2341" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHR_PL" b2="69 KV" b3="HIG-OAK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CASS" b2="69 KV" b3="CAS-OAK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKHILPL" b2="69 KV" b3="OAHILOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101244</SeqNum>
    <Name>L138.SulphurCity-ParrRun</Name>
    <LastEdit Timestamp="2025-07-24T16:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PARRRUN" b2="138 KV" b3="BKG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULPHRCI" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULPHRCI" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="PARRRUN" b2="138 KV" b3="PAR-SULP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101249</SeqNum>
    <Name>L230.Pocaty-Landstown.271</Name>
    <LastEdit Timestamp="2025-07-11T13:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="230 KV" b3="27152-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANDSTWN" b2="230 KV" b3="27152-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANDSTWN" b2="230 KV" b3="LAN-POTY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCATY" b2="230 KV" b3="27142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POCATY" b2="230 KV" b3="271T2240" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101251</SeqNum>
    <Name>230/69.Hummelstown.T3</Name>
    <LastEdit Timestamp="2025-07-22T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HUMMELST" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="230 KV" b3="TRAN-3-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="230 KV" b3="TRAN-3-W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="69 KV" b3="TRAN_3-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="69 KV" b3="TRAN_3-W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101252</SeqNum>
    <Name>HawTree.SP</Name>
    <LastEdit Timestamp="2024-08-20T07:22:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAWTREE" b2="115 KV" b3="104412" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAWTREE" b2="115 KV" b3="2212" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAWTREE" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HAWTREE" b2="34.5 KV" b3="HWTRCRSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101259</SeqNum>
    <Name>DTX138.Kirk.T2</Name>
    <LastEdit Timestamp="2025-09-23T11:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="138 KV" b3="L1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KIRK" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101260</SeqNum>
    <Name>DTX138.Marion.T6</Name>
    <LastEdit Timestamp="2025-09-23T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARION2" b2="138 KV" b3="T6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101261</SeqNum>
    <Name>DTX138.Marion.T5</Name>
    <LastEdit Timestamp="2025-09-23T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARION2" b2="138 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101262</SeqNum>
    <Name>DTX138.Marion.T4</Name>
    <LastEdit Timestamp="2025-09-23T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARION2" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101263</SeqNum>
    <Name>DTX138.McComb.T1</Name>
    <LastEdit Timestamp="2025-09-23T11:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCOMB" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCOMB" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCCOMB" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101264</SeqNum>
    <Name>138/69.Merrimac.TR1</Name>
    <LastEdit Timestamp="2025-10-10T12:31:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MERRIMAC" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERRIMAC" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERRIMAC" b2="138 KV" b3="S" />
      <ContingencyEquipment Action="X" Type="XF" b1="MERRIMAC" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101265</SeqNum>
    <Name>138/68.Merrimac.TR3</Name>
    <LastEdit Timestamp="2025-10-10T12:32:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MERRIMAC" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERRIMAC" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERRIMAC" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="X" Type="XF" b1="MERRIMAC" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101266</SeqNum>
    <Name>DTX138.MilanSS.XF1</Name>
    <LastEdit Timestamp="2025-09-23T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILANSS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILANSS" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILANSS" b2="138 KV" b3="XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101267</SeqNum>
    <Name>DTX138.MilanSS.XF2</Name>
    <LastEdit Timestamp="2025-09-23T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILANSS" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILANSS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILANSS" b2="138 KV" b3="XF2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101268</SeqNum>
    <Name>DTX138.MilanSS.XF3</Name>
    <LastEdit Timestamp="2025-11-04T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILANSS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILANSS" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILANSS" b2="138 KV" b3="XF3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101269</SeqNum>
    <Name>DTX138.Morse.T2</Name>
    <LastEdit Timestamp="2025-11-17T12:17:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="MORSE" b2="138 KV" b3="CAPAA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MORSE" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101270</SeqNum>
    <Name>DTX138.Morse.T3</Name>
    <LastEdit Timestamp="2025-11-21T12:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORSE" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MORSE" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101271</SeqNum>
    <Name>DTX138.Mound.T2</Name>
    <LastEdit Timestamp="2025-09-23T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUND" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUND" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MOUND" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101272</SeqNum>
    <Name>DTX138.MuskingumRiver.GLOBEMET</Name>
    <LastEdit Timestamp="2025-09-23T11:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MUSKING2" b2="138 KV" b3="GLOBEMET" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="138 KV" b3="HT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSKING2" b2="138 KV" b3="HU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101274</SeqNum>
    <Name>PennChemical.CC</Name>
    <LastEdit Timestamp="2024-08-20T11:03:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENNCHEM" b2="138 KV" b3="CT1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENNCHEM" b2="138 KV" b3="CT1GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENNCHEM" b2="138 KV" b3="CT2" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENNCHEM" b2="138 KV" b3="CT2GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENNCHEM" b2="138 KV" b3="CT3" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENNCHEM" b2="138 KV" b3="CT3GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PENNCHEM" b2="13 KV" b3="PACMSCT1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PENNCHEM" b2="13 KV" b3="PACMSCT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PENNCHEM" b2="13 KV" b3="PACMSCT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PENNCHEM" b2="13 KV" b3="PACMSST1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PENNCHEM" b2="13 KV" b3="PACMSST2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENNCHEM" b2="138 KV" b3="ST1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENNCHEM" b2="138 KV" b3="ST1GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENNCHEM" b2="138 KV" b3="ST2" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENNCHEM" b2="138 KV" b3="ST2GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101276</SeqNum>
    <Name>L138.DesPlaines-Busse-ElkGrove.4605</Name>
    <LastEdit Timestamp="2026-05-08T14:23:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="4605" b2="138 KV" b3="4605 7" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="152 BUSS" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="152 BUSS" b2="138 KV" b3="L4605 CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="4-5" />
      <ContingencyEquipment Action="L" Type="LN" b1="4605" b2="138 KV" b3="4605-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="4605" b2="138 KV" b3="4605-DES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="46 DESPL" b2="138 KV" b3="L4605 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="4605" b2="138 KV" b3="4605 3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101277</SeqNum>
    <Name>L138.ElkGrove-Rolling-Schaumburg.18411</Name>
    <LastEdit Timestamp="2025-05-08T14:02:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="18411" b2="138 KV" b3="18411 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="8-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="18411" b2="138 KV" b3="18411 3" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="206 ROLL" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="206 ROLL" b2="138 KV" b3="L18411CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="18411" b2="138 KV" b3="18411 2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="253 SCHA" b2="138 KV" b3="18411CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101278</SeqNum>
    <Name>DTX138.Magellan.TR2</Name>
    <LastEdit Timestamp="2025-07-14T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGELLAN" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGELLAN" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAGELLAN" b2="138 KV" b3="TR2_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101279</SeqNum>
    <Name>DTX138.Magellan.TR1</Name>
    <LastEdit Timestamp="2025-07-14T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGELLAN" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGELLAN" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAGELLAN" b2="138 KV" b3="TR1_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101280</SeqNum>
    <Name>L69.Frackville-Shenandoa-MahnyCty-Tamanend-Hauto.2</Name>
    <LastEdit Timestamp="2026-02-13T10:52:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AIRPROHT" b2="69 KV" b3="AIR-TAM2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AIRPROHT" b2="69 KV" b3="HOAP2_LD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DELANOPL" b2="69 KV" b3="2246" />
      <ContingencyEquipment Action="L" Type="LN" b1="AIRPROHT" b2="69 KV" b3="AIR-DEL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="FIS2SIE2" />
      <ContingencyEquipment Action="S" Type="SD" b1="FRACKVIL" b2="69 KV" b3="FR-RGTP" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRACKVIL" b2="69 KV" b3="FRA-SHE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="LRIDG2CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FRACKVIL" b2="69 KV" b3="LRIDGWF2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="SIEG2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAUTO" b2="69 KV" b3="2295" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAUTO" b2="69 KV" b3="2683" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAUTO" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MAHONYCI" b2="69 KV" b3="2381" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELANOPL" b2="69 KV" b3="DEL-MAH2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAHONYCI" b2="69 KV" b3="MACI2_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAHONYCI" b2="69 KV" b3="MAH-SHEN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHENAND" b2="69 KV" b3="2245" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHENAND" b2="69 KV" b3="KEANLOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHENAND" b2="69 KV" b3="T1LOAD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="TAMANEND" b2="69 KV" b3="CAP3" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAUTO" b2="69 KV" b3="HAU-TAMA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TAMANEND" b2="69 KV" b3="T3LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101281</SeqNum>
    <Name>L138.ElkGrove-Landmeir-Tonne-E552.18407</Name>
    <LastEdit Timestamp="2026-02-18T10:25:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="184 ELKG" b2="138 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="18407" b2="138 KV" b3="18407 1" />
      <ContingencyEquipment Action="L" Type="LN" b1="18407" b2="138 KV" b3="18407 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="18407" b2="138 KV" b3="18407 Z3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="207 TONN" b2="138 KV" b3="L18407CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="225 LAND" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="18407" b2="138 KV" b3="18407_4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E552" b2="138 KV" b3="5-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E552" b2="138 KV" b3="7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101282</SeqNum>
    <Name>345/138.WestMilton.BKE</Name>
    <LastEdit Timestamp="2025-10-29T09:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WMILTON" b2="345 KV" b3="BK-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="345 KV" b3="OC-AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="345 KV" b3="OC-DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="138 KV" b3="OC-F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="138 KV" b3="OC-H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101283</SeqNum>
    <Name>L345.Babbitt-Kirk</Name>
    <LastEdit Timestamp="2025-07-14T15:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="345 KV" b3="AD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="345 KV" b3="AE" />
      <ContingencyEquipment Action="L" Type="LN" b1="BABBITT" b2="345 KV" b3="BAB-KIRK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="345 KV" b3="C CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="345 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101284</SeqNum>
    <Name>DTX230.BrandonShores.AQCS1</Name>
    <LastEdit Timestamp="2025-09-24T12:20:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="2345_S6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRANDONS" b2="230 KV" b3="AQCS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="SWAQC56" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101285</SeqNum>
    <Name>DTX230.BrandonShores.AQCS2</Name>
    <LastEdit Timestamp="2025-09-24T12:19:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="130002OC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRANDONS" b2="230 KV" b3="1TR_P2TR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRANDONS" b2="230 KV" b3="AQCS2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101286</SeqNum>
    <Name>DTX500.CalvertCliffs.LD3</Name>
    <LastEdit Timestamp="2025-09-23T11:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALVERTC" b2="500 KV" b3="14" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CALVERTC" b2="500 KV" b3="LD3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101287</SeqNum>
    <Name>DTX115.Northeast.110-2</Name>
    <LastEdit Timestamp="2025-08-22T10:38:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NORTHEAS" b2="115 KV" b3="110-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="2TRF_10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101288</SeqNum>
    <Name>DTX115.Northeast.110-1</Name>
    <LastEdit Timestamp="2025-09-23T11:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NORTHEAS" b2="115 KV" b3="110-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="1101-581" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHEAS" b2="115 KV" b3="1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101289</SeqNum>
    <Name>DTX115.Orchards.110-1</Name>
    <LastEdit Timestamp="2025-09-23T11:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ORCHARDS" b2="115 KV" b3="110-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="110595" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="585_595" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101290</SeqNum>
    <Name>DTX115.Orchards.110-2</Name>
    <LastEdit Timestamp="2025-09-25T13:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ORCHARDS" b2="115 KV" b3="110-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="110596" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="586_596" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101291</SeqNum>
    <Name>DTX115.Orchards.110-3</Name>
    <LastEdit Timestamp="2025-09-25T13:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ORCHARDS" b2="115 KV" b3="110-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="110597" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="587_597" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101292</SeqNum>
    <Name>DTX115.Orchards.110-4</Name>
    <LastEdit Timestamp="2025-09-25T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ORCHARDS" b2="115 KV" b3="110-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="110598" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORCHARDS" b2="115 KV" b3="589_598" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101293</SeqNum>
    <Name>DTX115.Pumphrey.110-1</Name>
    <LastEdit Timestamp="2025-09-25T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PUMPHREY" b2="115 KV" b3="110-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="533_1TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="S110-1HS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101294</SeqNum>
    <Name>DTX115.Pumphrey.110-2</Name>
    <LastEdit Timestamp="2025-09-25T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PUMPHREY" b2="115 KV" b3="110-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="S110-2HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="S525_2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101295</SeqNum>
    <Name>DTX115.Tipton.110608LD</Name>
    <LastEdit Timestamp="2025-09-25T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="110608" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIPTON" b2="115 KV" b3="110608LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="608T610" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101296</SeqNum>
    <Name>DTX115.Tipton.110613LD</Name>
    <LastEdit Timestamp="2025-09-25T13:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="110613" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIPTON" b2="115 KV" b3="110613LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="611T613" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101297</SeqNum>
    <Name>DTX115.Tipton.110609LD</Name>
    <LastEdit Timestamp="2025-09-25T13:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="110609" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIPTON" b2="115 KV" b3="110609LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="2TR-609" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101298</SeqNum>
    <Name>DTX115.Tipton.110610LD</Name>
    <LastEdit Timestamp="2025-09-25T13:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="110610" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIPTON" b2="115 KV" b3="110610LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="608T610" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101299</SeqNum>
    <Name>DTX115.Tipton.110611LD</Name>
    <LastEdit Timestamp="2025-09-25T13:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="110611" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIPTON" b2="115 KV" b3="110611LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="611T613" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101300</SeqNum>
    <Name>DTX115.Tipton.110612LD</Name>
    <LastEdit Timestamp="2025-09-25T13:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="110612" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIPTON" b2="115 KV" b3="110612LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPTON" b2="115 KV" b3="612TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101301</SeqNum>
    <Name>DTX138.Itasca.TR77</Name>
    <LastEdit Timestamp="2025-07-15T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="10-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="9-10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="101 ITAS" b2="138 KV" b3="TR77 34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101302</SeqNum>
    <Name>DTX138.114Northwest.TR70</Name>
    <LastEdit Timestamp="2025-10-28T11:22:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT707 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT708 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="114 NORT" b2="138 KV" b3="TR70" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101303</SeqNum>
    <Name>DTX138.114Northwest.TR74-12</Name>
    <LastEdit Timestamp="2025-10-29T10:19:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT714 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT716 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="114 NORT" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101304</SeqNum>
    <Name>DTX138.114Northwest.TR78X-12 &amp; TR78Y-12</Name>
    <LastEdit Timestamp="2025-07-15T12:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT711 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT713 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="114 NORT" b2="138 KV" b3="TR78X 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="114 NORT" b2="138 KV" b3="TR78Y 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101305</SeqNum>
    <Name>DTX138.114Northwest.TR76X-12 &amp; TR76Y-12</Name>
    <LastEdit Timestamp="2025-07-14T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT723 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT725 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="114 NORT" b2="138 KV" b3="TR76X 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="114 NORT" b2="138 KV" b3="TR76Y 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101306</SeqNum>
    <Name>DTX138.114Northwest.TR77X-12 &amp; TR77Y-12</Name>
    <LastEdit Timestamp="2025-07-15T12:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT721 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT733 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="114 NORT" b2="138 KV" b3="TR77X 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="114 NORT" b2="138 KV" b3="TR77Y 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101307</SeqNum>
    <Name>DTX138.114Northwest.TR79X-12 &amp; TR79Y-12</Name>
    <LastEdit Timestamp="2025-07-15T12:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT708 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT710 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="114 NORT" b2="138 KV" b3="TR79X 12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="114 NORT" b2="138 KV" b3="TR79Y 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101308</SeqNum>
    <Name>DTX138.114Northwest.TR71-12</Name>
    <LastEdit Timestamp="2025-07-14T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT725 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT727 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="114 NORT" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101309</SeqNum>
    <Name>DTX138.114Northwest.TR72-12</Name>
    <LastEdit Timestamp="2025-07-14T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT722 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT728 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="114 NORT" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101310</SeqNum>
    <Name>DTX138.114Northwest.TR73-12</Name>
    <LastEdit Timestamp="2025-07-14T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT713 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="114 NORT" b2="138 KV" b3="BT717 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="114 NORT" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101311</SeqNum>
    <Name>DTX138.126State.TR74-12</Name>
    <LastEdit Timestamp="2025-07-15T12:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="126 STAT" b2="138 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="126 STAT" b2="138 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="126 STAT" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101312</SeqNum>
    <Name>DTX138.126State.TR72-12</Name>
    <LastEdit Timestamp="2025-07-15T12:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="126 STAT" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="126 STAT" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="126 STAT" b2="138 KV" b3="NISALSP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="126 STAT" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101313</SeqNum>
    <Name>DTX138.13Crawford.TR71-12</Name>
    <LastEdit Timestamp="2025-07-15T12:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B727 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B728 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="13 CRAWF" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101314</SeqNum>
    <Name>DTX138.13Crawford.TR72-12</Name>
    <LastEdit Timestamp="2025-10-29T10:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="112-212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B721 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B722 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="13 CRAWF" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101315</SeqNum>
    <Name>DTX138.13Crawford.TR73-12</Name>
    <LastEdit Timestamp="2025-07-15T12:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B718 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B720 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="13 CRAWF" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101316</SeqNum>
    <Name>DTX138.13Crawford.TR74-12</Name>
    <LastEdit Timestamp="2025-07-15T12:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B717 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="B719 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="13 CRAWF" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101317</SeqNum>
    <Name>DTX138.13Crawford.TR76-12</Name>
    <LastEdit Timestamp="2025-07-15T12:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT1-2GCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="13 CRAWF" b2="138 KV" b3="TR76 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101318</SeqNum>
    <Name>DTX138.13Crawford.TR77-12</Name>
    <LastEdit Timestamp="2025-07-15T12:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT5-14CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="C1-2 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="13 CRAWF" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="13 CRAWF" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="13 CRAWF" b2="138 KV" b3="TR77 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101319</SeqNum>
    <Name>DTX138.13Crawford.TR78-12</Name>
    <LastEdit Timestamp="2025-07-15T12:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT1213CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT1314CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="13 CRAWF" b2="138 KV" b3="TR78 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101320</SeqNum>
    <Name>DTX138.13Crawford.TR79-12</Name>
    <LastEdit Timestamp="2025-07-15T12:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT1415CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="13 CRAWF" b2="138 KV" b3="BT1516CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="13 CRAWF" b2="138 KV" b3="TR79 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101321</SeqNum>
    <Name>345/138.Babbitt.TR1</Name>
    <LastEdit Timestamp="2025-07-31T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="AB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="345 KV" b3="AC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="345 KV" b3="AD" />
      <ContingencyEquipment Action="X" Type="XF" b1="BABBITT" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101322</SeqNum>
    <Name>138/23.Aetna.TR1</Name>
    <LastEdit Timestamp="2025-07-15T12:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AETNA" b2="138 KV" b3="B166" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AETNA" b2="138 KV" b3="B171" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AETNA" b2="23 KV" b3="C" />
      <ContingencyEquipment Action="X" Type="XF" b1="AETNA" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101323</SeqNum>
    <Name>DTX138.Aetna.TR3</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AETNA" b2="138 KV" b3="B167" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AETNA" b2="138 KV" b3="B168" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AETNA" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101324</SeqNum>
    <Name>DTX138.154Libertyville.TR73</Name>
    <LastEdit Timestamp="2025-07-15T12:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="154 LIBE" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="154 LIBE" b2="138 KV" b3="TR73 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101329</SeqNum>
    <Name>DTX138.40Diversey.TR71</Name>
    <LastEdit Timestamp="2025-07-16T12:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="40 DIVER" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101330</SeqNum>
    <Name>DTX138.40Diversey.TR72</Name>
    <LastEdit Timestamp="2025-07-16T12:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="40 DIVER" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101331</SeqNum>
    <Name>DTX138.40Diversey.TR73</Name>
    <LastEdit Timestamp="2025-07-16T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="40 DIVER" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101332</SeqNum>
    <Name>DTX138.40Diversey.TR74</Name>
    <LastEdit Timestamp="2025-07-16T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT1-5 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="40 DIVER" b2="138 KV" b3="BT4-5 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="40 DIVER" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101333</SeqNum>
    <Name>DTX138.45Jefferson.TR71</Name>
    <LastEdit Timestamp="2026-01-02T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="45 JEFFE" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="TR71CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101334</SeqNum>
    <Name>DTX138.45Jefferson.TR72</Name>
    <LastEdit Timestamp="2025-07-16T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT1-12CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT1112CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="45 JEFFE" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101335</SeqNum>
    <Name>DTX138.45Jefferson.TR73</Name>
    <LastEdit Timestamp="2025-07-16T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="45 JEFFE" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101336</SeqNum>
    <Name>DTX138.45Jefferson.TR74</Name>
    <LastEdit Timestamp="2025-07-17T15:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="45 JEFFE" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="X" Type="XF" b1="45 JEFFE" b2="138 KV" b3="TR77 69" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="45 JEFFE" b2="69 KV" b3="TR77 D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101337</SeqNum>
    <Name>DTX138.82Crosby.TR71</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1-8 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="82 CROSB" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101338</SeqNum>
    <Name>DTX138.82Crosby.TR72</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="82 CROSB" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101339</SeqNum>
    <Name>DTX138.82Crosby.TR73</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1617CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1718CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="82 CROSB" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101340</SeqNum>
    <Name>DTX138.82Crosby.TR74</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1213CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="82 CROSB" b2="138 KV" b3="BT1314CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="82 CROSB" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101343</SeqNum>
    <Name>DTX138.J310.TR2</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="J310" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="J310" b2="138 KV" b3="L1807 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="J310" b2="138 KV" b3="LY1 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="J310" b2="138 KV" b3="TR2 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101344</SeqNum>
    <Name>DTX138.J310.TR1</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="J310" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="J310" b2="138 KV" b3="L5104 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="J310" b2="138 KV" b3="TR1 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101345</SeqNum>
    <Name>DTX138.174University.TR71</Name>
    <LastEdit Timestamp="2025-07-16T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="174 UNIV" b2="138 KV" b3="38L17401" />
      <ContingencyEquipment Action="OP" Type="CB" b1="174 UNIV" b2="138 KV" b3="BT1-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="174 UNIV" b2="138 KV" b3="TR71" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101346</SeqNum>
    <Name>DTX138.174University.TR72</Name>
    <LastEdit Timestamp="2025-07-16T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="174 UNIV" b2="138 KV" b3="BT1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="174 UNIV" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="174 UNIV" b2="138 KV" b3="L17404" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="174 UNIV" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101347</SeqNum>
    <Name>DTX138.174University.TR73</Name>
    <LastEdit Timestamp="2025-07-16T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="174 UNIV" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="174 UNIV" b2="138 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="174 UNIV" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101348</SeqNum>
    <Name>DTX138.179Bloom.TR71</Name>
    <LastEdit Timestamp="2025-07-16T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="179 BLOO" b2="138 KV" b3="38TR71CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="179 BLOO" b2="138 KV" b3="TR71 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101349</SeqNum>
    <Name>DTX138.179Bloom.LOAD</Name>
    <LastEdit Timestamp="2025-05-13T08:42:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="179 BLOO" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="179 BLOO" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="179 BLOO" b2="138 KV" b3="C1-2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="179 BLOO" b2="138 KV" b3="TR72_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101350</SeqNum>
    <Name>L138.58Grand-65Ohio.5805</Name>
    <LastEdit Timestamp="2025-07-15T13:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1119CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="58 GRAND" b2="138 KV" b3="BT1819CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="58 GRAND" b2="138 KV" b3="5805 Z1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="65 OHIO" b2="138 KV" b3="TR75 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101354</SeqNum>
    <Name>L138.Brokaw-Normal</Name>
    <LastEdit Timestamp="2025-11-25T16:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BROKAW" b2="138 KV" b3="BRO-TOWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="138 KV" b3="H21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="138 KV" b3="H23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORMAL 3" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORMAL 3" b2="138 KV" b3="H7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWANDA" b2="138 KV" b3="BROKAW" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORMAL 3" b2="138 KV" b3="NOR-TOWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWANDA" b2="138 KV" b3="NORMAL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101355</SeqNum>
    <Name>500/230.Ladysmith.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-29T12:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="LADYSMTH" b2="500 KV" b3="H214M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LADYSMTH" b2="230 KV" b3="L2T2089" />
      <ContingencyEquipment Action="X" Type="XF" b1="LADYSMTH" b2="500 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101357</SeqNum>
    <Name>DTX69.Argentum.LOAD</Name>
    <LastEdit Timestamp="2026-03-31T15:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARGNT_EK" b2="69 KV" b3="CB738" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ARGNT_EK" b2="69 KV" b3="LD_189" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101358</SeqNum>
    <Name>DTX138.Gallatin.25KVLD</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GALLATIN" b2="138 KV" b3="25KVLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALLATIN" b2="138 KV" b3="844" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALLATIN" b2="138 KV" b3="CB824" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101359</SeqNum>
    <Name>DTX138.Gallatin.34KVLD</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GALLATIN" b2="138 KV" b3="34.5KVLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALLATIN" b2="138 KV" b3="844" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALLATIN" b2="138 KV" b3="CB814" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101360</SeqNum>
    <Name>DTX138.Spurlock.T28</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB918" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB95T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPURLOCK" b2="138 KV" b3="T28" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101361</SeqNum>
    <Name>DTX138.Spurlock.T27</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB908" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB95T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPURLOCK" b2="138 KV" b3="T27" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101362</SeqNum>
    <Name>DTX138.Spurlock.G1SVCLD</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB802" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="138 KV" b3="CB90T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPURLOCK" b2="138 KV" b3="G1SVCLD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101363</SeqNum>
    <Name>DTX345.Spurlock.G4SVCLD</Name>
    <LastEdit Timestamp="2025-07-17T16:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB1488" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPURLOCK" b2="345 KV" b3="CB152T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPURLOCK" b2="345 KV" b3="G4SVCLD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101364</SeqNum>
    <Name>DTX138.Anguin.1B</Name>
    <LastEdit Timestamp="2025-12-04T17:34:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ANGUIN" b2="138 KV" b3="1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="H005F8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101365</SeqNum>
    <Name>138/69.WolfGlad.T3</Name>
    <LastEdit Timestamp="2025-07-17T15:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFGLAD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFGLAD" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFGLAD" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOLFGLAD" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101366</SeqNum>
    <Name>L69.Byllesby-WolfGlad</Name>
    <LastEdit Timestamp="2025-07-17T16:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BYLLESBY" b2="69 KV" b3="BYL-WOLF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BYLLESBY" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFGLAD" b2="69 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101367</SeqNum>
    <Name>L69.ShelbyCo-Logan-Budd-Bekaert-WShelby(LGEE).Tie</Name>
    <LastEdit Timestamp="2025-11-14T16:44:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEKAERT" b2="69 KV" b3="BEK-WSHE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEKAERT" b2="69 KV" b3="BEKARET1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEKAERT" b2="69 KV" b3="BEKARET2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEKAERT" b2="69 KV" b3="BEKARET3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEKAERT" b2="69 KV" b3="BEK-BUDD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUDD" b2="69 KV" b3="BUD-LOGA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUDD" b2="69 KV" b3="LD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOGAN_EK" b2="69 KV" b3="LD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOGAN_EK" b2="69 KV" b3="LD2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOGAN_EK" b2="69 KV" b3="LOG-SHEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBYCO" b2="69 KV" b3="N53-644" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHELBY2" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSHELBY2" b2="69 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101368</SeqNum>
    <Name>230/138.WestHempfield.T4</Name>
    <LastEdit Timestamp="2025-07-18T13:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WHEMPFIE" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="230 KV" b3="TRAN4HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="138 KV" b3="TRAN_4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101369</SeqNum>
    <Name>L115.Glory-DixonvilleEast.1091 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-11T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="DIXONVIL" b2="115 KV" b3="GLORY115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLORY" b2="115 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLORY" b2="115 KV" b3="B48" />
      <ContingencyEquipment Action="L" Type="LN" b1="DIXONVIL" b2="115 KV" b3="DIX-GLO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101370</SeqNum>
    <Name>L115.DixonvilleEast-TradeCity.1091 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DIXONVIL" b2="115 KV" b3="DIX-TRA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DIXONVIL" b2="115 KV" b3="TRADE115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRADECIT" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRADECIT" b2="115 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101371</SeqNum>
    <Name>L115.Garman-Westover.991 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GARMAN" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARMAN" b2="115 KV" b3="GAR-WES" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WESTOVER" b2="115 KV" b3="GARMANMO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101373</SeqNum>
    <Name>L115.Madera-BioEnergy-Shawville.991 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-06-03T11:49:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIOENRGY" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIOENRGY" b2="115 KV" b3="BIO-SHA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BIOENRGY" b2="115 KV" b3="CLEARFLD" />
      <ContingencyEquipment Action="X" Type="XF" b1="MADERA" b2="115 KV" b3="2TX" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MADERA" b2="34.5 KV" b3="2TXLDIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIOENRGY" b2="115 KV" b3="BIO-MAD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MADERA" b2="115 KV" b3="SHWVLMOA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWVILL" b2="115 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101374</SeqNum>
    <Name>L115.TyroneNorth-Westfall.1037</Name>
    <LastEdit Timestamp="2025-10-15T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TYRONEN" b2="115 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYRONEN" b2="115 KV" b3="B14" />
      <ContingencyEquipment Action="L" Type="LN" b1="TYRONEN" b2="115 KV" b3="TYR-WES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTFALL" b2="115 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTFALL" b2="115 KV" b3="B15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101375</SeqNum>
    <Name>L115.EagleValley-TyroneNorth.1037</Name>
    <LastEdit Timestamp="2025-10-09T12:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLEVAL" b2="115 KV" b3="1137-B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLEVAL" b2="115 KV" b3="1137-B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="EAGLEVAL" b2="115 KV" b3="EAG-TYR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYRONEN" b2="115 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYRONEN" b2="115 KV" b3="B16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101376</SeqNum>
    <Name>L115.Krayn-Salix (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KRAYN" b2="115 KV" b3="1123CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KRAYN" b2="115 KV" b3="1123CB2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KRAYN" b2="115 KV" b3="KRA-SAL" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SALIX" b2="115 KV" b3="CLAYSBMO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101377</SeqNum>
    <Name>L115.Hilltop-RachelHill-Salix (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTOP" b2="115 KV" b3="B44" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTOP" b2="115 KV" b3="B50" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLCJCT" b2="115 KV" b3="HIL-HIL" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLCJCT" b2="115 KV" b3="HIL-RAC" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RACHELHI" b2="115 KV" b3="HILCJMOA" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLCJCT" b2="115 KV" b3="HIL-SAL" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SALIX" b2="115 KV" b3="HILCJ MO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101378</SeqNum>
    <Name>L115.Curryville-Saxton.1099 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-06-30T08:51:52" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CURRYVIL" b2="115 KV" b3="12RS MOA" />
      <ContingencyEquipment Action="L" Type="LN" b1="CURRYVIL" b2="115 KV" b3="CUR-SAX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAXTON" b2="115 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SAXTON" b2="115 KV" b3="CURRYAUX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101379</SeqNum>
    <Name>L115.Claysburg-Curryville.1099 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSBUR" b2="115 KV" b3="B48" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSBUR" b2="115 KV" b3="B49" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYSBUR" b2="115 KV" b3="CLA-CUR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CURRYVIL" b2="115 KV" b3="12RC MOA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101380</SeqNum>
    <Name>L115.ShadeGap-ThreeSprings (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHADEGAP" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHADEGAP" b2="115 KV" b3="SHA-THR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="THREESPR" b2="115 KV" b3="A2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101381</SeqNum>
    <Name>L115.Saxton-ThreeSprings (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SAXTON" b2="115 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SAXTON" b2="115 KV" b3="D37" />
      <ContingencyEquipment Action="L" Type="LN" b1="SAXTON" b2="115 KV" b3="SAX-THR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="THREESPR" b2="115 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101382</SeqNum>
    <Name>L115.RachelHill-ScalpLevel (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-11T15:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RACHELHI" b2="115 KV" b3="B24" />
      <ContingencyEquipment Action="L" Type="LN" b1="RACHELHI" b2="115 KV" b3="RAC-SCA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SCALPLEV" b2="115 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101383</SeqNum>
    <Name>L115.Hooversville-ScalpLevel (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOOVERSV" b2="115 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SCALPLEV" b2="115 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOOVERSV" b2="115 KV" b3="HOO-SCA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101384</SeqNum>
    <Name>L115.Somerset-Ralphton (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="RALPHTON" b2="115 KV" b3="RAL-SOM" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RALPHTON" b2="115 KV" b3="SOMRST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOME PN" b2="115 KV" b3="RALPHTSF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101385</SeqNum>
    <Name>L115.Hooversville-Ralphton (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOOVERSV" b2="115 KV" b3="B27" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOOVERSV" b2="115 KV" b3="HOO-RAL" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RALPHTON" b2="115 KV" b3="HOVRV MO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101386</SeqNum>
    <Name>L230.HomerCity-Quemahoning.2024 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="230 KV" b3="207" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOMERCIT" b2="230 KV" b3="208" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOMERCIT" b2="230 KV" b3="HOM-QUE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="QUEMAHON" b2="230 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101387</SeqNum>
    <Name>L230.Hooversville-Quemahoning.2024 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-12-23T10:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOOVERSV" b2="230 KV" b3="B53" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="QUEMAHON" b2="230 KV" b3="A3" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOOVERSV" b2="230 KV" b3="HOO-QUE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101388</SeqNum>
    <Name>L115.Lucerne-Edgewood.1036 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEWOOD" b2="115 KV" b3="EDG-LUC" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EDGEWOOD" b2="115 KV" b3="LUCRNMO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUCERNE" b2="115 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101389</SeqNum>
    <Name>L115.Edgewood.Shelocta.1036 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-09T15:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="EDGEWOOD" b2="115 KV" b3="A184" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDGEWOOD" b2="115 KV" b3="EDG-SHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELOCTA" b2="115 KV" b3="B52" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101390</SeqNum>
    <Name>L115.PierceBrook-TwoMile (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="115 KV" b3="B13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERCEBR" b2="115 KV" b3="B14" />
      <ContingencyEquipment Action="L" Type="LN" b1="PIERCEBR" b2="115 KV" b3="PIE-TWO" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TWOMILE" b2="115 KV" b3="PIERCE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101391</SeqNum>
    <Name>L115.TwoMile-Potter (Sctnlz)</Name>
    <LastEdit Timestamp="2025-12-11T15:11:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="POTTER" b2="115 KV" b3="BT CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="POTTER" b2="115 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTTER" b2="46 KV" b3="T1LCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="POTTER" b2="115 KV" b3="POT-TWO" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TWOMILE" b2="115 KV" b3="POTTER" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101392</SeqNum>
    <Name>L115.NilesValley-Sabinsville (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NILESVAL" b2="115 KV" b3="B53" />
      <ContingencyEquipment Action="L" Type="LN" b1="NILESVAL" b2="115 KV" b3="NIL-SAB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SABINSVI" b2="115 KV" b3="NILV MOA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101393</SeqNum>
    <Name>L115.Sabinsville-Hector (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-23T16:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HECTOR" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HECTOR" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HECTOR" b2="115 KV" b3="HEC-SAB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SABINSVI" b2="115 KV" b3="POTTENOA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101394</SeqNum>
    <Name>L230.Lackawanna-Oxbow (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-16T15:09:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="NMESH_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACKAWAN" b2="230 KV" b3="NMES_T3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OXBOW" b2="230 KV" b3="D7" />
      <ContingencyEquipment Action="L" Type="LN" b1="LACKAWAN" b2="230 KV" b3="LAC-OXB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101395</SeqNum>
    <Name>L230.Oxbow-NMeshoppen (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-01T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="230 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="230 KV" b3="B28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OXBOW" b2="230 KV" b3="CS1TX" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OXBOW" b2="230 KV" b3="D8" />
      <ContingencyEquipment Action="L" Type="LN" b1="NMESHOPP" b2="230 KV" b3="NME-OXB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OXBOW" b2="34.5 KV" b3="OXBOWGT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OXBOW" b2="34.5 KV" b3="OXBOW_LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="OXBOW" b2="230 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101396</SeqNum>
    <Name>L115.Grandview-Haynie (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GRANDVIE" b2="115 KV" b3="GRA-HAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDVIE" b2="115 KV" b3="PINEY115" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAYNIE" b2="115 KV" b3="GRNVWMOA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101397</SeqNum>
    <Name>L115.Haynie-Piney (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAYNIE" b2="115 KV" b3="PINEY115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEY" b2="115 KV" b3="GRANDVW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEY" b2="115 KV" b3="GRANDVWA" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAYNIE" b2="115 KV" b3="HAY-PIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101398</SeqNum>
    <Name>L115.Elipse-Clarksummit.1009 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLARKSUM" b2="115 KV" b3="CLA-ECL" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLARKSUM" b2="115 KV" b3="ECLIPSMO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ECLIPSE" b2="115 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101399</SeqNum>
    <Name>L115.Clarksummit-Grandview.1009 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-18T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLARKSUM" b2="115 KV" b3="CLA-GRA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLARKSUM" b2="115 KV" b3="GRNVW MO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANDVIE" b2="115 KV" b3="ECLIPSE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101400</SeqNum>
    <Name>L115.UticaJct.Wayne.1010 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-11-12T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="UTICAJCT" b2="115 KV" b3="A5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAYNE" b2="115 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="UTICAJCT" b2="115 KV" b3="UTI-WAY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101401</SeqNum>
    <Name>L115.Eclipse.UticaJct.1010 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-11-13T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ECLIPSE" b2="115 KV" b3="B10" />
      <ContingencyEquipment Action="L" Type="LN" b1="ECLIPSE" b2="115 KV" b3="ECL-UTI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="UTICAJCT" b2="115 KV" b3="A4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101404</SeqNum>
    <Name>L115.Roundtop-Allen.981-2</Name>
    <LastEdit Timestamp="2026-05-26T16:54:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLEN" b2="115 KV" b3="ALL-ROU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLEN" b2="115 KV" b3="B35" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLEN" b2="115 KV" b3="B9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTOP" b2="115 KV" b3="B98172" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101405</SeqNum>
    <Name>L115.Edinboro-VenangoJunction (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDINBORO" b2="115 KV" b3="B27" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDINBORO" b2="115 KV" b3="EDI-VEN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="VENANJCT" b2="115 KV" b3="EDNBRMOA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101406</SeqNum>
    <Name>L115.MorganStreet-VenangoJunction (Sctnlz)</Name>
    <LastEdit Timestamp="2025-12-23T10:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANST" b2="115 KV" b3="B43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VENANJCT" b2="115 KV" b3="MOR S MO" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORGANST" b2="115 KV" b3="MOR-VEN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101407</SeqNum>
    <Name>L115.Springboro-VenangoJunction (Sctnlz)</Name>
    <LastEdit Timestamp="2025-12-24T10:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGBO" b2="115 KV" b3="B15" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPRINGBO" b2="115 KV" b3="SPR-VEN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="VENANJCT" b2="115 KV" b3="A30" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101408</SeqNum>
    <Name>L115.HarveyRun-Whetstone.982 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-05-15T09:14:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="HARVEYRN" b2="115 KV" b3="CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVEYRN" b2="115 KV" b3="CAP CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARVEYRN" b2="115 KV" b3="HAR-WHE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARVEYRN" b2="115 KV" b3="WTSTONMO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHETSTON" b2="115 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101409</SeqNum>
    <Name>L115.Dubois-HarveyRun.982 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-12-30T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUBOIS" b2="115 KV" b3="B4" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUBOIS" b2="115 KV" b3="DUB-HAR" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HARVEYRN" b2="115 KV" b3="CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVEYRN" b2="115 KV" b3="CAP CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARVEYRN" b2="115 KV" b3="DUBOISMO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101413</SeqNum>
    <Name>115/34.SouthTroy.TX1&amp;2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="STROY" b2="115 KV" b3="A1TX" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STROY" b2="115 KV" b3="A2TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STROY" b2="34 KV" b3="B1TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STROY" b2="34 KV" b3="B2TX" />
      <ContingencyEquipment Action="X" Type="XF" b1="STROY" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="STROY" b2="115 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101414</SeqNum>
    <Name>L115.Hill-Bair (Sctnlz)</Name>
    <LastEdit Timestamp="2024-12-18T16:29:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAIR" b2="115 KV" b3="96919" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILL" b2="115 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILL" b2="115 KV" b3="B20" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAIR" b2="115 KV" b3="BAI-HIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101415</SeqNum>
    <Name>L115.Bair-Jackson (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAIR" b2="115 KV" b3="96916" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="115 KV" b3="B19" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAIR" b2="115 KV" b3="BAI-JAC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101416</SeqNum>
    <Name>L115.BuffaloRoad-DowningAve (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BUFFALRD" b2="115 KV" b3="BUF-DOW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFALRD" b2="115 KV" b3="GREEN_GR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWNGAVE" b2="115 KV" b3="BUFFRDMO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101417</SeqNum>
    <Name>L115.DowningAve-GreenGarden (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DOWNGAVE" b2="115 KV" b3="DOW-GRN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWNGAVE" b2="115 KV" b3="GRNGARDM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENGAR" b2="115 KV" b3="BUFLO_RD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101418</SeqNum>
    <Name>115/35.DowningAve.3TRAN (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DOWNGAVE" b2="115 KV" b3="3TRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWNGAVE" b2="35 KV" b3="3TRLSCB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DOWNGAVE" b2="115 KV" b3="3TX115SW" />
      <ContingencyEquipment Action="CL" Type="CB" b1="DOWNGAVE" b2="35 KV" b3="BUSTIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101420</SeqNum>
    <Name>L230.Shelocta-Keystone.2014</Name>
    <LastEdit Timestamp="2024-06-20T20:47:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="230 KV" b3="10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTONE" b2="230 KV" b3="20" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEYSTONE" b2="230 KV" b3="KEY-SHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELOCTA" b2="230 KV" b3="B34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELOCTA" b2="230 KV" b3="B37" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101421</SeqNum>
    <Name>L115.Gardners-Dillsburg.973 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DILLSBUR" b2="115 KV" b3="97369" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARDNERS" b2="115 KV" b3="97382" />
      <ContingencyEquipment Action="L" Type="LN" b1="DILLSBUR" b2="115 KV" b3="DIL-GAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101422</SeqNum>
    <Name>L115.Dillsburg-Roundtop.973 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DILLSBUR" b2="115 KV" b3="97366" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTOP" b2="115 KV" b3="B97372" />
      <ContingencyEquipment Action="L" Type="LN" b1="DILLSBUR" b2="115 KV" b3="DIL-ROU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101423</SeqNum>
    <Name>L115.VioletHill-MtRose.983 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-23T16:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MTROSE" b2="115 KV" b3="98369DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIOLET H" b2="115 KV" b3="98332" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTROSE" b2="115 KV" b3="MTR-VIO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101424</SeqNum>
    <Name>L115.MtRose-Pleasureville.983 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MTROSE" b2="115 KV" b3="98366DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLVL ME" b2="115 KV" b3="98372" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTROSE" b2="115 KV" b3="MTR-PLV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101425</SeqNum>
    <Name>L115.Hunterstown-Oxford (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="115 KV" b3="96092" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTERST" b2="115 KV" b3="HUN-OXF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OXFORD" b2="115 KV" b3="96009" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101426</SeqNum>
    <Name>L115.Oxford-NorthHanover (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NHANOVER" b2="115 KV" b3="96032" />
      <ContingencyEquipment Action="L" Type="LN" b1="NHANOVER" b2="115 KV" b3="NHA-OXF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OXFORD" b2="115 KV" b3="96006" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101427</SeqNum>
    <Name>L115.Tolna-Crossroads.990 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSROA" b2="115 KV" b3="99046" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOLNA" b2="115 KV" b3="99002" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROSSROA" b2="115 KV" b3="CRO-TOL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101428</SeqNum>
    <Name>L115.Crossroads-Windsor.990 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSROA" b2="115 KV" b3="99049" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WIND ME" b2="115 KV" b3="99032" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROSSROA" b2="115 KV" b3="CRO-WIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101429</SeqNum>
    <Name>L115.MiddleJct-YrkHav-LocustP-ZionsVw.977 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-11-21T14:30:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOCUSTPR" b2="115 KV" b3="LOAD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOCUSTPR" b2="115 KV" b3="LOC-ZION" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="115 KV" b3="B97742" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDDLJCT" b2="115 KV" b3="MID-YOR7" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOCUSTPR" b2="115 KV" b3="LOC-YORK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKHAVE" b2="115 KV" b3="T-970" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ZIONSVIE" b2="115 KV" b3="97716DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101430</SeqNum>
    <Name>L115.ZionsView-SmithStreet.977 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-11-21T14:30:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHST" b2="115 KV" b3="97702" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHST" b2="115 KV" b3="97708" />
      <ContingencyEquipment Action="L" Type="LN" b1="SMITHST" b2="115 KV" b3="SMI-ZIO" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ZIONSVIE" b2="115 KV" b3="97719DIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101431</SeqNum>
    <Name>L115.WhiteFord-Glades.987 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLADES" b2="115 KV" b3="1 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLADES" b2="115 KV" b3="B98732" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLADES" b2="115 KV" b3="GLA-WHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEFOR" b2="115 KV" b3="98749" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101432</SeqNum>
    <Name>L115.CatTractor-WhiteFord.987 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CATTRACT" b2="115 KV" b3="98712" />
      <ContingencyEquipment Action="L" Type="LN" b1="CATTRACT" b2="115 KV" b3="CAT-WHI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEFOR" b2="115 KV" b3="98746" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101433</SeqNum>
    <Name>L115.Glades-WestHellam.972 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-12-29T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLADES" b2="115 KV" b3="2 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLADES" b2="115 KV" b3="B98732" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLADES" b2="115 KV" b3="GLA-WHE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WHELLAM" b2="115 KV" b3="A97219" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101434</SeqNum>
    <Name>L115.WestHellam-Prospect-Yorkana.972 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-08-20T09:16:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PROSPEME" b2="115 KV" b3="LD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PROSPEME" b2="115 KV" b3="PRO-YOR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WHELLAM" b2="115 KV" b3="A97216" />
      <ContingencyEquipment Action="L" Type="LN" b1="PROSPEME" b2="115 KV" b3="PRO-WHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="115 KV" b3="97282CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101435</SeqNum>
    <Name>L115.Jackson-JEBaker-Taxville.966 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JACK ME" b2="115 KV" b3="B18" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACK ME" b2="115 KV" b3="JAC-JEB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JEBAKER" b2="115 KV" b3="1 BANK" />
      <ContingencyEquipment Action="L" Type="LN" b1="JEBAKER" b2="115 KV" b3="JEB-TAX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAXVILLE" b2="115 KV" b3="96636" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101436</SeqNum>
    <Name>L115.Taxville-Westgate.966 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TAXVILLE" b2="115 KV" b3="96639" />
      <ContingencyEquipment Action="L" Type="LN" b1="TAXVILLE" b2="115 KV" b3="TAX-WES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTGATE" b2="115 KV" b3="B96612" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101437</SeqNum>
    <Name>L115.ElmStreetTap-ElmStreet (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ELMST" b2="115 KV" b3="BK1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ELMST" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELMST" b2="34.5 KV" b3="ELMSTLD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELMSTTAP" b2="115 KV" b3="A35" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMST" b2="115 KV" b3="ELM-ELM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101438</SeqNum>
    <Name>L115.ElmStreetTap-WarrenSouth (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-21T09:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELMSTTAP" b2="115 KV" b3="A34" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMSTTAP" b2="115 KV" b3="ELM-WRS" />
      <ContingencyEquipment Action="X" Type="XF" b1="WARRENS" b2="115 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WARRENS" b2="34.5 KV" b3="WARRNSLD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101439</SeqNum>
    <Name>L115.Yorkana-Redfront-Yoe-Springwood.988 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-29T16:24:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REDFRONT" b2="115 KV" b3="TRAN1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SPRINGWO" b2="115 KV" b3="A14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YOE" b2="115 KV" b3="98869" />
      <ContingencyEquipment Action="L" Type="LN" b1="SPRINGWO" b2="115 KV" b3="SPR-YOE" />
      <ContingencyEquipment Action="CL" Type="CB" b1="YOE" b2="115 KV" b3="T989" />
      <ContingencyEquipment Action="L" Type="LN" b1="YOE" b2="115 KV" b3="YOE-RED" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="115 KV" b3="98882-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="REDFRONT" b2="115 KV" b3="RED-YORK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101441</SeqNum>
    <Name>L115.VioletHill-QueenSt-Springwood.988 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-30T15:28:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="QUEEN ST" b2="115 KV" b3="2 BANK" />
      <ContingencyEquipment Action="L" Type="LN" b1="QUEEN ST" b2="115 KV" b3="QUE-VIO" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SPRINGWO" b2="115 KV" b3="A13" />
      <ContingencyEquipment Action="L" Type="LN" b1="QUEEN ST" b2="115 KV" b3="QUE-SPR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIOLET H" b2="115 KV" b3="98832" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101442</SeqNum>
    <Name>L115.Queenst-VioletHill.988 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-07-23T16:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="QUEEN ST" b2="115 KV" b3="98869" />
      <ContingencyEquipment Action="L" Type="LN" b1="QUEEN ST" b2="115 KV" b3="QUE-VIO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIOLET H" b2="115 KV" b3="98832" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101443</SeqNum>
    <Name>L161.Joppa-Shawnee.4 (TVA)</Name>
    <LastEdit Timestamp="2025-10-29T10:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOPPA_N" b2="161 KV" b3="1620" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOPPA_N" b2="161 KV" b3="1621" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOPPA_N" b2="161 KV" b3="JOP-SHA4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHAWNEE4" b2="161 KV" b3="1041" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEE4" b2="161 KV" b3="1044" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101444</SeqNum>
    <Name>138/69.Trebein.BK-8</Name>
    <LastEdit Timestamp="2025-07-22T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="09TREBEI" b2="138 KV" b3="BK-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09TREBEI" b2="69 KV" b3="BL-8N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09TREBEI" b2="69 KV" b3="BL-8S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09TREBEI" b2="138 KV" b3="GB-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09TREBEI" b2="138 KV" b3="GB-D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101446</SeqNum>
    <Name>138/69.Chadwick.T2</Name>
    <LastEdit Timestamp="2025-07-29T12:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CHADWICK" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHADWICK" b2="69 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHADWICK" b2="69 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHADWICK" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101448</SeqNum>
    <Name>L138.FlintRun-WaldoRun.1</Name>
    <LastEdit Timestamp="2025-09-03T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="138 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLINTRUN" b2="138 KV" b3="FLI-WAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="B111" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="B112" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101449</SeqNum>
    <Name>L138.FlintRun-WaldoRun.2</Name>
    <LastEdit Timestamp="2025-09-03T09:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLINTRUN" b2="138 KV" b3="FLI-WAL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALDORUN" b2="138 KV" b3="8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101450</SeqNum>
    <Name>230/115.Farmville.TX4</Name>
    <LastEdit Timestamp="2025-07-22T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="230 KV" b3="H432" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="115 KV" b3="L432" />
      <ContingencyEquipment Action="X" Type="XF" b1="FARMVILL" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101451</SeqNum>
    <Name>L138.SulphurCity-ElkGarden-KelsoGap</Name>
    <LastEdit Timestamp="2025-07-24T16:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELKGARDE" b2="138 KV" b3="ELK-KEL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELKGARDE" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSOGAP" b2="138 KV" b3="1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSOGAP" b2="138 KV" b3="2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULPHRCI" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULPHRCI" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKGARDE" b2="138 KV" b3="ELK-SULP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101452</SeqNum>
    <Name>L230.RollinsFord-Gainesville</Name>
    <LastEdit Timestamp="2026-05-11T11:41:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAINESVL" b2="230 KV" b3="23462222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAINESVL" b2="230 KV" b3="H3T2222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROLNSFRD" b2="230 KV" b3="222252-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROLNSFRD" b2="230 KV" b3="222252-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GAINESVL" b2="230 KV" b3="GAI-ROLN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101453</SeqNum>
    <Name>L230.RollinsFord-ElkRun-RemingtonCT</Name>
    <LastEdit Timestamp="2025-08-29T13:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELKRUNDP" b2="230 KV" b3="2114A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELKRUNDP" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="21142155" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMNTNCT" b2="230 KV" b3="211462" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROLNSFRD" b2="230 KV" b3="211452-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROLNSFRD" b2="230 KV" b3="211452-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELKRUNDP" b2="230 KV" b3="ELK-ROLN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101454</SeqNum>
    <Name>DTX.RollinsFord.DPW54</Name>
    <LastEdit Timestamp="2025-07-24T16:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROLNSFRD" b2="230 KV" b3="211452-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROLNSFRD" b2="230 KV" b3="222252-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROLNSFRD" b2="230 KV" b3="DP_W54" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101455</SeqNum>
    <Name>DTX.RollinsFord.DPY54</Name>
    <LastEdit Timestamp="2025-07-24T16:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROLNSFRD" b2="230 KV" b3="211452-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROLNSFRD" b2="230 KV" b3="222252-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROLNSFRD" b2="230 KV" b3="DP_Y54" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101456</SeqNum>
    <Name>L500.FlintRun-Harrison.598</Name>
    <LastEdit Timestamp="2025-10-22T14:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="500 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLINTRUN" b2="500 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLINTRUN" b2="500 KV" b3="FLI-HARR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR APS" b2="500 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARR APS" b2="500 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101457</SeqNum>
    <Name>L345.Tristate-Baker</Name>
    <LastEdit Timestamp="2026-01-06T11:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="345 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAKER" b2="345 KV" b3="J2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRISTATE" b2="345 KV" b3="TRI-BAK1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="345 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="345 KV" b3="H2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101459</SeqNum>
    <Name>L138.WolfGlade-JubalEarly</Name>
    <LastEdit Timestamp="2025-07-31T14:00:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUBALEAR" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="JUBALEAR" b2="138 KV" b3="JUB-WOLF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFGLAD" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFGLAD" b2="138 KV" b3="A1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101460</SeqNum>
    <Name>L138.JubalEarly-Austinville-Wythe</Name>
    <LastEdit Timestamp="2025-07-31T14:01:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AUSTINVI" b2="138 KV" b3="AUS-JUB1" />
      <ContingencyEquipment Action="L" Type="LN" b1="AUSTINVI" b2="138 KV" b3="AUS-WYT1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AUSTINVI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUBALEAR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYTHE" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101461</SeqNum>
    <Name>138/69.JubalEarly.T2</Name>
    <LastEdit Timestamp="2025-07-24T16:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUBALEAR" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="X" Type="XF" b1="JUBALEAR" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUBALEAR" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101462</SeqNum>
    <Name>L230.Essex-Hudson.A2227</Name>
    <LastEdit Timestamp="2025-07-25T16:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="13-14CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESSEX" b2="230 KV" b3="2-14CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUDSON" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="ESSEX" b2="230 KV" b3="ESS-HUD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101463</SeqNum>
    <Name>230/138.HuntersGlen.220-3 + HuntersGlen.F-1384</Name>
    <LastEdit Timestamp="2025-08-01T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HUNTGLEN" b2="230 KV" b3="220-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTGLEN" b2="230 KV" b3="220-3CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="HUNTGLEN" b2="138 KV" b3="F-1384" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUNTGLEN" b2="138 KV" b3="FORREST" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101464</SeqNum>
    <Name>230/35.Winterpock.TX1</Name>
    <LastEdit Timestamp="2025-10-02T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERPK" b2="230 KV" b3="H14T2066" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERPK" b2="230 KV" b3="H14T219" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERPK" b2="230 KV" b3="H152" />
      <ContingencyEquipment Action="X" Type="XF" b1="WINTERPK" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WINTERPK" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101465</SeqNum>
    <Name>Rawlings.SV2</Name>
    <LastEdit Timestamp="2025-07-25T16:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="RAWLINGS" b2="500 KV" b3="2BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RAWLINGS" b2="500 KV" b3="2BUCK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RAWLINGS" b2="500 KV" b3="SV2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAWLINGS" b2="500 KV" b3="SV292" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101466</SeqNum>
    <Name>L138.Chadwick-Bellefonte</Name>
    <LastEdit Timestamp="2025-07-24T16:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEFON" b2="138 KV" b3="V" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLEFON" b2="138 KV" b3="BEL-CHAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHADWICK" b2="138 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101467</SeqNum>
    <Name>L138.Chadwick-Grangston</Name>
    <LastEdit Timestamp="2025-07-25T16:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHADWICK" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANGSTO" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHADWICK" b2="138 KV" b3="CHA-GRAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101468</SeqNum>
    <Name>L138.Cloverdale-Brlngt-Catawba-WSalem-GlenMary</Name>
    <LastEdit Timestamp="2025-07-25T16:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BURLING2" b2="138 KV" b3="BUR-CAT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURLING2" b2="138 KV" b3="BUR-CLO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BURLING2" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CATAWBA" b2="138 KV" b3="CAT-WSA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERD2" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENMARY" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENMARY" b2="138 KV" b3="GLE-WSAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WSALEM" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101469</SeqNum>
    <Name>L138.GlenMary-MattFunk</Name>
    <LastEdit Timestamp="2025-07-25T16:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENMARY" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENMARY" b2="138 KV" b3="GLE-MATT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MATTFUN2" b2="138 KV" b3="J2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101470</SeqNum>
    <Name>161/69.FoxHollow.TR1</Name>
    <LastEdit Timestamp="2025-07-25T15:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FOX_HOLL" b2="161 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX_HOLL" b2="161 KV" b3="W18-1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX_HOLL" b2="69 KV" b3="W18-678" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101478</SeqNum>
    <Name>138/69.BlueJacket.T1</Name>
    <LastEdit Timestamp="2025-07-25T15:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEJACK" b2="69 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEJACK" b2="69 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEJACK" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUEJACK" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BLUEJACK" b2="69 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101480</SeqNum>
    <Name>115/23.Roxbury.T3</Name>
    <LastEdit Timestamp="2026-01-20T17:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBURY" b2="115 KV" b3="B32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBURY" b2="115 KV" b3="B33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBURY" b2="23 KV" b3="B7" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROXBURY" b2="115 KV" b3="NO3 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101481</SeqNum>
    <Name>L230.BullRun-Clifton.2212</Name>
    <LastEdit Timestamp="2025-07-28T11:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRUN" b2="230 KV" b3="244T2212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BULLRUN" b2="230 KV" b3="265T2212" />
      <ContingencyEquipment Action="L" Type="LN" b1="BULLRUN" b2="230 KV" b3="BUL-CLIF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTON" b2="230 KV" b3="21642212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFTON" b2="230 KV" b3="221282" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101482</SeqNum>
    <Name>L345.Arcadian-Granville (WEC)</Name>
    <LastEdit Timestamp="2026-01-30T14:28:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARCADIAN" b2="345 KV" b3="9268" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARCADIAN" b2="345 KV" b3="9269" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARCADIAN" b2="345 KV" b3="ARC-GRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANVILL" b2="345 KV" b3="9357" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANVILL" b2="345 KV" b3="9358" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101483</SeqNum>
    <Name>L138.CregoRoad-Glidden.8302</Name>
    <LastEdit Timestamp="2025-07-28T11:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="189_CREG" b2="138 KV" b3="7-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="189_CREG" b2="138 KV" b3="9-10" />
      <ContingencyEquipment Action="L" Type="LN" b1="189_CREG" b2="138 KV" b3="CRE-GLI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="83 GLIDD" b2="138 KV" b3="BT1-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="83 GLIDD" b2="138 KV" b3="BT8-9 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101484</SeqNum>
    <Name>345/138.Varner.T1</Name>
    <LastEdit Timestamp="2025-07-28T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VARNRAEP" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VARNRAEP" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VARNRAEP" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="X" Type="XF" b1="VARNRAEP" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101485</SeqNum>
    <Name>L345.Varner-SouthButler</Name>
    <LastEdit Timestamp="2025-07-28T11:53:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SBUTLER" b2="345 KV" b3="52H-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VARNRAEP" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="SBUTLER" b2="345 KV" b3="SBU-VAR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101488</SeqNum>
    <Name>Millstone.U2 (NEISO)</Name>
    <LastEdit Timestamp="2025-07-28T11:52:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MILLSTON" b2="345 KV" b3="2X" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLSTON" b2="345 KV" b3="8T_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLSTON" b2="345 KV" b3="9T_2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MILLSTON" b2="24 KV" b3="MIL2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101489</SeqNum>
    <Name>Millstone.U3 (NEISO)</Name>
    <LastEdit Timestamp="2025-07-28T11:51:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLSTON" b2="345 KV" b3="13T_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLSTON" b2="345 KV" b3="14T_2" />
      <ContingencyEquipment Action="X" Type="XF" b1="MILLSTON" b2="345 KV" b3="3X" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MILLSTON" b2="24 KV" b3="MIL3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101493</SeqNum>
    <Name>L138.WhiteSU-Midway</Name>
    <LastEdit Timestamp="2025-07-28T11:55:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="4WHITESU" b2="138 KV" b3="702" />
      <ContingencyEquipment Action="OP" Type="CB" b1="4WHITESU" b2="138 KV" b3="724" />
      <ContingencyEquipment Action="L" Type="LN" b1="4WHITESU" b2="138 KV" b3="4WH-MIDW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWY_KU" b2="138 KV" b3="B747_705" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101494</SeqNum>
    <Name>L138.Midway-WestLexington</Name>
    <LastEdit Timestamp="2025-07-28T11:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWY_KU" b2="138 KV" b3="B747_705" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDWY_KU" b2="138 KV" b3="LD_153" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDWY_KU" b2="138 KV" b3="WLE-MIDW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_LXNGT" b2="138 KV" b3="B154_714" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_LXNGT" b2="138 KV" b3="B154_717" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101495</SeqNum>
    <Name>L138.Boar-Sandburg (Ameren)</Name>
    <LastEdit Timestamp="2025-07-28T11:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOAR" b2="138 KV" b3="BOA-SAND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOAR" b2="138 KV" b3="H6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDBRG" b2="138 KV" b3="H31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDBRG" b2="138 KV" b3="H33" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101508</SeqNum>
    <Name>L69.Frackville-MahonyCty-Tamanend-Hauto.1</Name>
    <LastEdit Timestamp="2026-03-05T15:19:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AIRPROHT" b2="69 KV" b3="AIR-DEL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="AIRPROHT" b2="69 KV" b3="AIR-TAM1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AIRPROHT" b2="69 KV" b3="HOAP1_LD" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="DELANOPL" b2="69 KV" b3="2246" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DELANOPL" b2="69 KV" b3="2247" />
      <ContingencyEquipment Action="S" Type="SD" b1="FRACKVIL" b2="69 KV" b3="FR-GLBT" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRACKVIL" b2="69 KV" b3="FRA-MAHO" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FRACKVIL" b2="69 KV" b3="GLBNUG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="SIE1ORW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="SIEG1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GRNWDTP" b2="69 KV" b3="2215" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRNWDTP" b2="69 KV" b3="GRN-TAMA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRNWDTP" b2="69 KV" b3="GRWOLOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAUTO" b2="69 KV" b3="HAU-GRW" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAUTO" b2="69 KV" b3="2294" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAUTO" b2="69 KV" b3="2683" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAUTO" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MAHONYCI" b2="69 KV" b3="2381" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELANOPL" b2="69 KV" b3="DEL-MAH1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAHONYCI" b2="69 KV" b3="GIMALOAD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MAHONYCI" b2="69 KV" b3="LRIDGWF1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAHONYCI" b2="69 KV" b3="MACI1_LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MAHONYCI" b2="69 KV" b3="PRIMLOAD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="TAMANEND" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TAMANEND" b2="69 KV" b3="T1LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101509</SeqNum>
    <Name>L69.Frackville-Tuscarora</Name>
    <LastEdit Timestamp="2024-11-27T10:51:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FRACKVIL" b2="69 KV" b3="FRA-TUSC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="HAUT1_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="HAUT1_W" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRNWDTP" b2="69 KV" b3="GRN-TUSC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101510</SeqNum>
    <Name>L69.Frackville-Shenandoah.2</Name>
    <LastEdit Timestamp="2025-05-13T09:53:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="FRACKVIL" b2="69 KV" b3="FR-SCEN" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRACKVIL" b2="69 KV" b3="FRA-SHE2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FRACKVIL" b2="69 KV" b3="SCENUG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="SECNUGGE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="SHE2ORW2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="SHEN2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHENAND" b2="69 KV" b3="2245" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHENAND" b2="69 KV" b3="T2LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101511</SeqNum>
    <Name>L138.H440-H447RR</Name>
    <LastEdit Timestamp="2025-11-17T15:13:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="H440" b2="138 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H440" b2="138 KV" b3="1-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="H447RR" b2="138 KV" b3="HRR-H440" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H447RR" b2="138 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H447RR" b2="138 KV" b3="1-9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101512</SeqNum>
    <Name>SmithPond.MerrinSP</Name>
    <LastEdit Timestamp="2025-12-08T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SMTHPOND" b2="115 KV" b3="104382" />
      <ContingencyEquipment Action="S" Type="SD" b1="SMTHPOND" b2="115 KV" b3="104382SD" />
      <ContingencyEquipment Action="X" Type="XF" b1="SMTHPOND" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SMTHPOND" b2="34.5 KV" b3="PUMPKISP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101514</SeqNum>
    <Name>Guernsey.CC </Name>
    <LastEdit Timestamp="2026-02-10T09:43:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GUERNSEY" b2="230 KV" b3="11ADA" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUERNSEY" b2="230 KV" b3="11BAT01" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUERNSEY" b2="23 KV" b3="11CC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUERNSEY" b2="230 KV" b3="21ADA" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUERNSEY" b2="230 KV" b3="21BAT02" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUERNSEY" b2="23 KV" b3="21CC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUERNSEY" b2="230 KV" b3="31ADA" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUERNSEY" b2="230 KV" b3="31BAT03" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUERNSEY" b2="23 KV" b3="31CC" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GUERNSEY" b2="23 KV" b3="AUX1LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GUERNSEY" b2="23 KV" b3="AUX2LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GUERNSEY" b2="23 KV" b3="AUX3LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUERNSEY" b2="765 KV" b3="G" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUERNSEY" b2="765 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101517</SeqNum>
    <Name>Hannibal.CC</Name>
    <LastEdit Timestamp="2025-07-29T14:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNIBAL" b2="24 KV" b3="52G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNIBAL" b2="138 KV" b3="52L" />
      <ContingencyEquipment Action="X" Type="XF" b1="HANNIBAL" b2="138 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HANNIBAL" b2="24 KV" b3="LONGRDCC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101518</SeqNum>
    <Name>Katydid.TopCrop.2.WF</Name>
    <LastEdit Timestamp="2025-07-29T14:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="196 KATY" b2="34.5 KV" b3="4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="196 KATY" b2="345 KV" b3="GCB153" />
      <ContingencyEquipment Action="U" Type="GEN" b1="196 KATY" b2="34.5 KV" b3="TCROP2WF" />
      <ContingencyEquipment Action="X" Type="XF" b1="196 KATY" b2="345 KV" b3="TR87" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101519</SeqNum>
    <Name>MoleCreek.Minonk.WF</Name>
    <LastEdit Timestamp="2025-05-13T08:44:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="908 MOLE" b2="34.5 KV" b3="CAP CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="908 MOLE" b2="345 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="908 MOLE" b2="34.5 KV" b3="L1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="908 MOLE" b2="34.5 KV" b3="MINONKWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="908 MOLE" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101520</SeqNum>
    <Name>Swamp.Desert.WF</Name>
    <LastEdit Timestamp="2025-07-29T14:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SWAMP" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SWAMP" b2="34.5 KV" b3="DESERTWF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWAMP" b2="230 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101521</SeqNum>
    <Name>L138.199Kensington-949KellyCreek.19902+KellyCrk.WF</Name>
    <LastEdit Timestamp="2025-07-31T14:05:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="199 KENS" b2="138 KV" b3="L19902" />
      <ContingencyEquipment Action="L" Type="LN" b1="199 KENS" b2="138 KV" b3="19902" />
      <ContingencyEquipment Action="OP" Type="CB" b1="949 KELL" b2="34.5 KV" b3="35RB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="949 KELL" b2="34.5 KV" b3="35RB2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="949 KELL" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="949 KELL" b2="34.5 KV" b3="CAP2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="949 KELL" b2="34.5 KV" b3="CAP3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="949 KELL" b2="34.5 KV" b3="CAP4" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="949 KELL" b2="34.5 KV" b3="CAP5" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="949 KELL" b2="34.5 KV" b3="CAP6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="949 KELL" b2="138 KV" b3="CB138-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="949 KELL" b2="138 KV" b3="CB138-2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="949 KELL" b2="34.5 KV" b3="KELLYCWF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="949 KELL" b2="34.5 KV" b3="PCB35" />
      <ContingencyEquipment Action="X" Type="XF" b1="949 KELL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="949 KELL" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101522</SeqNum>
    <Name>Portland.CT5</Name>
    <LastEdit Timestamp="2025-07-29T14:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTLAND" b2="230 KV" b3="B512" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PORTLAND" b2="13 KV" b3="CT 5" />
      <ContingencyEquipment Action="X" Type="XF" b1="PORTLAND" b2="230 KV" b3="G5 TX 2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTLAND" b2="13 KV" b3="G52" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101526</SeqNum>
    <Name>L138.189CREG-83GLIDD.L8309</Name>
    <LastEdit Timestamp="2025-07-29T14:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="189_CREG" b2="138 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="189_CREG" b2="138 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="189_CREG" b2="138 KV" b3="CRE-GLI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="83 GLIDD" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="83 GLIDD" b2="138 KV" b3="BT2-3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101527</SeqNum>
    <Name>L230.Brunswick-Huntglen.S-2324</Name>
    <LastEdit Timestamp="2025-07-29T14:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRUNSWIC" b2="230 KV" b3="BRU-HUNT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SEC13-14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRUNSWIC" b2="230 KV" b3="SECT3-13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTGLEN" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTGLEN" b2="230 KV" b3="4-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101528</SeqNum>
    <Name>L345.StClair-Stephens</Name>
    <LastEdit Timestamp="2025-07-29T14:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR" b2="345 KV" b3="BM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR" b2="345 KV" b3="BT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEPHNS2" b2="345 KV" b3="EF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEPHNS2" b2="345 KV" b3="EM" />
      <ContingencyEquipment Action="L" Type="LN" b1="STCLAIR" b2="345 KV" b3="STC-STE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101529</SeqNum>
    <Name>138/23.Newark.132-1TX</Name>
    <LastEdit Timestamp="2025-07-29T14:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NEWARK" b2="138 KV" b3="132-1TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="5-6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWARK" b2="26 KV" b3="LD1XFR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101530</SeqNum>
    <Name>138/23.Newark.132-2TX</Name>
    <LastEdit Timestamp="2025-08-01T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NEWARK" b2="138 KV" b3="132-2TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="7-8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWARK" b2="26 KV" b3="LD2XFR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101531</SeqNum>
    <Name>138/23.Newark.132-3TX</Name>
    <LastEdit Timestamp="2025-08-01T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NEWARK" b2="138 KV" b3="132-3TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="4-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="9-10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWARK" b2="26 KV" b3="LD3XFR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101532</SeqNum>
    <Name>138/23.Newark.132-4TX</Name>
    <LastEdit Timestamp="2025-08-01T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="11-12" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEWARK" b2="138 KV" b3="132-4TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWARK" b2="138 KV" b3="4-12" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWARK" b2="26 KV" b3="LD4XFR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101534</SeqNum>
    <Name>DTX230.HuntersGlen.T-1</Name>
    <LastEdit Timestamp="2025-07-31T12:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTGLEN" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTGLEN" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUNTGLEN" b2="230 KV" b3="T-1LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101535</SeqNum>
    <Name>L345.Marysville-Peoria</Name>
    <LastEdit Timestamp="2025-07-31T12:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="345 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="345 KV" b3="G2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARYSVI2" b2="345 KV" b3="MAR-PEOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEORIA" b2="345 KV" b3="CE-AA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101536</SeqNum>
    <Name>DTX138.Beatty.T6</Name>
    <LastEdit Timestamp="2025-07-31T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="M1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEATTY" b2="138 KV" b3="T6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101537</SeqNum>
    <Name>765/138.Broadford.T5</Name>
    <LastEdit Timestamp="2025-08-04T12:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="765 KV" b3="N1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADFO2" b2="765 KV" b3="N2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BROADFO2" b2="765 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101538</SeqNum>
    <Name>L345.DuntonLake-SouthButler.1</Name>
    <LastEdit Timestamp="2025-07-31T12:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNTONLK" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNTONLK" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUNTONLK" b2="345 KV" b3="DUN-SBU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBUTLER" b2="345 KV" b3="52H-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101539</SeqNum>
    <Name>L345.DuntonLake-SouthButler.2 </Name>
    <LastEdit Timestamp="2025-08-04T13:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNTONLK" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNTONLK" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUNTONLK" b2="345 KV" b3="DUN-SBU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBUTLER" b2="345 KV" b3="52H-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101540</SeqNum>
    <Name>DTX138.Babbitt.T4</Name>
    <LastEdit Timestamp="2025-07-31T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BABBITT" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101541</SeqNum>
    <Name>DTX138.Babbitt.T5</Name>
    <LastEdit Timestamp="2025-07-31T12:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="E2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BABBITT" b2="138 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101542</SeqNum>
    <Name>L230.Mercer-Whitehorse.D-2309</Name>
    <LastEdit Timestamp="2025-08-13T14:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MERCER" b2="230 KV" b3="MER-WHIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCER" b2="230 KV" b3="SECT3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCER" b2="230 KV" b3="SECT4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITHRSE" b2="230 KV" b3="1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITHRSE" b2="230 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101543</SeqNum>
    <Name>230/69.Whitehorse.220-1TR</Name>
    <LastEdit Timestamp="2025-08-13T13:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITHRSE" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHITHRSE" b2="230 KV" b3="220-1TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITHRSE" b2="69 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITHRSE" b2="69 KV" b3="4-5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101544</SeqNum>
    <Name>Rappahanock.SR1</Name>
    <LastEdit Timestamp="2025-07-31T12:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="RAPPAHAN" b2="115 KV" b3="SR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPPAHAN" b2="115 KV" b3="SR112" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101545</SeqNum>
    <Name>Rappahanock.SR2</Name>
    <LastEdit Timestamp="2025-07-31T12:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="RAPPAHAN" b2="115 KV" b3="SR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPPAHAN" b2="115 KV" b3="SR212" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101550</SeqNum>
    <Name>L69.Columbia-University-Scott.1</Name>
    <LastEdit Timestamp="2025-02-19T08:36:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="COLU PL" b2="69 KV" b3="GLB1INSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="69 KV" b3="GLBR1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SCOTTPL" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCOTTPL" b2="69 KV" b3="SCOT1 LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLU PL" b2="69 KV" b3="COL-UNI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCOTTPL" b2="69 KV" b3="SCO-UNI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIVERPL" b2="69 KV" b3="UNIV_LD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101565</SeqNum>
    <Name>345/69.Peoria.BK-S</Name>
    <LastEdit Timestamp="2025-08-01T13:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PEORIA" b2="345 KV" b3="BK-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEORIA" b2="69 KV" b3="CE-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEORIA" b2="69 KV" b3="CE-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEORIA" b2="345 KV" b3="CE-AA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101567</SeqNum>
    <Name>L115.GoreJct-FairviewEast</Name>
    <LastEdit Timestamp="2024-06-11T11:15:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRVIEW" b2="115 KV" b3="B31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOREJCT" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAIRVIEW" b2="115 KV" b3="FAI-GOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101568</SeqNum>
    <Name>115/13.Tarboro.TX2</Name>
    <LastEdit Timestamp="2025-08-01T13:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TARBORO" b2="115 KV" b3="H272" />
      <ContingencyEquipment Action="X" Type="XF" b1="TARBORO" b2="115 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101569</SeqNum>
    <Name>138/69.Jay.T2</Name>
    <LastEdit Timestamp="2025-08-04T12:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JAY" b2="69 KV" b3="Q" />
      <ContingencyEquipment Action="X" Type="XF" b1="JAY" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JAY" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101570</SeqNum>
    <Name>230/69.HuntersGlen.220-1</Name>
    <LastEdit Timestamp="2025-08-04T12:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTGLEN" b2="69 KV" b3="2-10" />
      <ContingencyEquipment Action="X" Type="XF" b1="HUNTGLEN" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTGLEN" b2="230 KV" b3="220-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTGLEN" b2="69 KV" b3="9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101571</SeqNum>
    <Name>SandyPond.DC.Tie (NEISO) + LX.PratJct</Name>
    <LastEdit Timestamp="2025-08-22T08:20:40" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="P1_P2_T" b2="345 KV" b3="HQP2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="PRAT_J" b2="115 KV" b3="6X_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDYPON" b2="345 KV" b3="1412" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDYPON" b2="345 KV" b3="2137" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDYPON" b2="345 KV" b3="3512" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDYPON" b2="345 KV" b3="3521" />
      <ContingencyEquipment Action="L" Type="LN" b1="P1_P2_T" b2="345 KV" b3="P1P-SAN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="P1_P2_T" b2="345 KV" b3="P1P-SAN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101572</SeqNum>
    <Name>L161.Joppa-Shawnee.2 (TVA)</Name>
    <LastEdit Timestamp="2025-10-29T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOPPA_N" b2="161 KV" b3="1604" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOPPA_N" b2="161 KV" b3="JOP-SHA2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHAWNEE4" b2="161 KV" b3="1001" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEE4" b2="161 KV" b3="1004" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101573</SeqNum>
    <Name>Gibson.U1</Name>
    <LastEdit Timestamp="2025-08-04T13:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="GIBSON2" b2="345 KV" b3="BK 1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GIBSON2" b2="24 KV" b3="UN 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON2" b2="24 KV" b3="UN1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON2" b2="345 KV" b3="UN1_7EA9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101576</SeqNum>
    <Name>230/138.Lafayette.T4(Cinergy)</Name>
    <LastEdit Timestamp="2025-08-04T12:59:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08LAFYTE" b2="138 KV" b3="138230-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08LAFYTE" b2="230 KV" b3="230138-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="08LAFYTE" b2="230 KV" b3="4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101580</SeqNum>
    <Name>L161.EBowlingGreen-SouthGlasgow (TVA)</Name>
    <LastEdit Timestamp="2025-08-19T16:27:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="5BRSTOKY" b2="161 KV" b3="914" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="5TRANSPK" b2="161 KV" b3="147_LD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="5TRANSPK" b2="161 KV" b3="CAP01" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRSTO_T" b2="161 KV" b3="BRS-5BRS" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRSTO_T" b2="161 KV" b3="BRS-TRA" />
      <ContingencyEquipment Action="L" Type="LN" b1="E_BOWL" b2="161 KV" b3="EBO-BRS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E_BOWL" b2="161 KV" b3="934" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="E_BOWL" b2="161 KV" b3="939" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLASG_T" b2="161 KV" b3="GLA-SGLA" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLASG_T" b2="161 KV" b3="GLA-TRA" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLSGWKY" b2="161 KV" b3="GLS-GLA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GLSGWKY" b2="161 KV" b3="LD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SGLASGOW" b2="161 KV" b3="924" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SGLASGOW" b2="161 KV" b3="938" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101584</SeqNum>
    <Name>DTX138.Republic.T2</Name>
    <LastEdit Timestamp="2025-09-25T13:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REPUBLIC" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REPUBLIC" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REPUBLIC" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101585</SeqNum>
    <Name>DTX138.Sawmill.T2</Name>
    <LastEdit Timestamp="2025-09-25T13:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="101C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="101N" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SAWMILL" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101586</SeqNum>
    <Name>DTX138.Sawmill.T3</Name>
    <LastEdit Timestamp="2025-09-25T13:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="101C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAWMILL" b2="138 KV" b3="101S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SAWMILL" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101587</SeqNum>
    <Name>DTX138.StClair.T3</Name>
    <LastEdit Timestamp="2025-09-25T13:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STCLAIR2" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STCLAIR2" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101588</SeqNum>
    <Name>DTX138.Kenny.T1</Name>
    <LastEdit Timestamp="2025-09-25T13:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNY" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNY" b2="138 KV" b3="106" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KENNY" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101589</SeqNum>
    <Name>DTX138.Tidd.T301 &amp; T13</Name>
    <LastEdit Timestamp="2025-10-01T16:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="L1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIDD_AEP" b2="138 KV" b3="T13" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIDD_AEP" b2="138 KV" b3="T301" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101590</SeqNum>
    <Name>DTX138.Tidd.FGDA</Name>
    <LastEdit Timestamp="2025-09-29T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIDD_AEP" b2="138 KV" b3="FGD A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="J1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101591</SeqNum>
    <Name>DTX138.Tidd.FGDB</Name>
    <LastEdit Timestamp="2025-09-29T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIDD_AEP" b2="138 KV" b3="FGD B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="H2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101592</SeqNum>
    <Name>DTX138.Tidd.T14</Name>
    <LastEdit Timestamp="2025-09-29T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIDD_AEP" b2="138 KV" b3="J-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIDD_AEP" b2="138 KV" b3="T14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101593</SeqNum>
    <Name>DTX138.Timken.T2</Name>
    <LastEdit Timestamp="2025-09-29T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMKEN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMKEN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIMKEN" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101594</SeqNum>
    <Name>DTX138.Timken.T3</Name>
    <LastEdit Timestamp="2025-09-29T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMKEN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMKEN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TIMKEN" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101595</SeqNum>
    <Name>DTX138.Unioncam.T2&amp;3</Name>
    <LastEdit Timestamp="2025-10-01T16:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIONCAM" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIONCAM" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIONCAM" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIONCAM" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101596</SeqNum>
    <Name>DTX138.Vine.T1</Name>
    <LastEdit Timestamp="2025-09-29T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VINE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101597</SeqNum>
    <Name>DTX138.Vine.T2</Name>
    <LastEdit Timestamp="2025-09-29T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="107" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VINE" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101598</SeqNum>
    <Name>DTX138.Vine.T3</Name>
    <LastEdit Timestamp="2025-09-29T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINE" b2="138 KV" b3="108" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VINE" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101599</SeqNum>
    <Name>DTX138.Arsenal.T1</Name>
    <LastEdit Timestamp="2025-09-29T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ARSENAL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="138 KV" b3="TIE 1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="138 KV" b3="TIE 1-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101600</SeqNum>
    <Name>DTX138.Arsenal.T2</Name>
    <LastEdit Timestamp="2025-09-29T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ARSENAL" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="138 KV" b3="TIE 2-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="138 KV" b3="TIE 2-7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101601</SeqNum>
    <Name>DTX138.Arsenal.T3</Name>
    <LastEdit Timestamp="2026-03-30T18:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ARSENAL" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="138 KV" b3="TIE 3-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARSENAL" b2="138 KV" b3="TIE 4-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101602</SeqNum>
    <Name>DTX138.Carson.LOADDUM</Name>
    <LastEdit Timestamp="2025-10-01T16:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARS DUQ" b2="138 KV" b3="BUSTIE13" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CARS DUQ" b2="138 KV" b3="LOADDUM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARS DUQ" b2="138 KV" b3="Z-88" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101604</SeqNum>
    <Name>DTX69.Dravosburg.T2</Name>
    <LastEdit Timestamp="2025-03-12T16:51:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAVOSBU" b2="69 KV" b3="T2 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DRAVOSBU" b2="69 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101606</SeqNum>
    <Name>DTX138.Findlay.T1</Name>
    <LastEdit Timestamp="2025-09-29T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FINDLAY" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINDLAY" b2="138 KV" b3="CLINTON" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FINDLAY" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101607</SeqNum>
    <Name>DTX138.Findlay.T2</Name>
    <LastEdit Timestamp="2025-09-29T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FINDLAY" b2="138 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINDLAY" b2="138 KV" b3="MONTOUR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FINDLAY" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101608</SeqNum>
    <Name>DTX138.HighlandDUQ.T1</Name>
    <LastEdit Timestamp="2025-09-29T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGH DUQ" b2="138 KV" b3="BUSTIE12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGH DUQ" b2="138 KV" b3="LOGAN59" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIGH DUQ" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101609</SeqNum>
    <Name>DTX138.HighlandDUQ.T2</Name>
    <LastEdit Timestamp="2025-09-29T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGH DUQ" b2="138 KV" b3="ARSENAL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGH DUQ" b2="138 KV" b3="BUSTIE12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGH DUQ" b2="138 KV" b3="BUSTIE23" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIGH DUQ" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101610</SeqNum>
    <Name>DTX138.HighlandDUQ.T3</Name>
    <LastEdit Timestamp="2025-09-29T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGH DUQ" b2="138 KV" b3="BUSTIE23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGH DUQ" b2="138 KV" b3="LOGAN60" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIGH DUQ" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101612</SeqNum>
    <Name>DTX138.Anguin.1A</Name>
    <LastEdit Timestamp="2025-12-10T16:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ANGUIN" b2="138 KV" b3="1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="H005G8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101613</SeqNum>
    <Name>138/69/34.EastLynchburg.T1</Name>
    <LastEdit Timestamp="2025-08-13T13:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BWAEP" b2="69 KV" b3="M" />
      <ContingencyEquipment Action="L" Type="LN" b1="BWAEP" b2="69 KV" b3="BWA-ELY" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELYNCHBU" b2="34.5 KV" b3="PEAKSVW" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELYNCHBU" b2="138 KV" b3="T1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELYNCHBU" b2="69 KV" b3="T1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="ELYNCHBU" b2="34.5 KV" b3="T1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELYNCHBU" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101614</SeqNum>
    <Name>L138.Aladdin-Strawton</Name>
    <LastEdit Timestamp="2025-08-13T13:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALADDIN" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALADDIN" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALADDIN" b2="138 KV" b3="ALA-STR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRAWTON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRAWTON" b2="138 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101615</SeqNum>
    <Name>345/138.TriState.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-13T13:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TRISTATE" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="138 KV" b3="F2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TRISTATE" b2="345 KV" b3="X2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101616</SeqNum>
    <Name>L345.Meredos-Turn (AMRN/MISO)</Name>
    <LastEdit Timestamp="2025-08-13T14:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MEREDOS3" b2="345 KV" b3="MER-TURN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEREDOS3" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEREDOS3" b2="345 KV" b3="V15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURN" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURN" b2="345 KV" b3="V11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101617</SeqNum>
    <Name>L345.Behv-Cahokia (MISO)</Name>
    <LastEdit Timestamp="2025-08-13T14:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BEHV" b2="345 KV" b3="BEH-CAHO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEHV" b2="345 KV" b3="V43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEHV" b2="345 KV" b3="V45" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAHOKIA3" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAHOKIA3" b2="345 KV" b3="V5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101618</SeqNum>
    <Name>L138.SouthStTap-Boar (Ameren)</Name>
    <LastEdit Timestamp="2025-08-19T16:35:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOAR" b2="138 KV" b3="BOA-STHS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOAR" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOAR" b2="138 KV" b3="H5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STHSTTAP" b2="138 KV" b3="LOAD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="STHSTTAP" b2="138 KV" b3="S ST T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STHSTTAP" b2="138 KV" b3="ST TAP42" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101623</SeqNum>
    <Name>161/138.Hazard.T3</Name>
    <LastEdit Timestamp="2025-08-13T13:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HAZARD" b2="161 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZARD" b2="161 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZARD" b2="138 KV" b3="Q" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101624</SeqNum>
    <Name>L138.EBeaver-Marquis</Name>
    <LastEdit Timestamp="2025-08-13T13:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MARQUIS2" b2="138 KV" b3="EBE-MAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEAVER" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEAVER" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="138 KV" b3="P1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101625</SeqNum>
    <Name>138/69.BlossomTrail.TR2</Name>
    <LastEdit Timestamp="2025-08-14T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BLOSSOMT" b2="138 KV" b3="2-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLOSSOMT" b2="69 KV" b3="2-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLOSSOMT" b2="34 KV" b3="2-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLOSSOMT" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLOSSOMT" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLOSSOMT" b2="34 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLOSSOMT" b2="69 KV" b3="N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101626</SeqNum>
    <Name>DTX230.HuntersGlen.T-2</Name>
    <LastEdit Timestamp="2025-08-14T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTGLEN" b2="230 KV" b3="4-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTGLEN" b2="230 KV" b3="5-6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUNTGLEN" b2="230 KV" b3="T-2LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101628</SeqNum>
    <Name>L138.Aetna-Evans</Name>
    <LastEdit Timestamp="2025-08-19T16:06:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AETNA" b2="138 KV" b3="AET-EVAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AETNA" b2="138 KV" b3="B166" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AETNA" b2="138 KV" b3="B167" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVANSOE" b2="138 KV" b3="B110" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101629</SeqNum>
    <Name>L138.Museville-SmithMountain</Name>
    <LastEdit Timestamp="2025-09-04T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSEVILL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MUSEVILL" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHMOU" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MUSEVILL" b2="138 KV" b3="MUS-SMIT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101630</SeqNum>
    <Name>DanRiverCT.ST07 (DUKE)</Name>
    <LastEdit Timestamp="2025-08-14T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DANRV CT" b2="100 KV" b3="BK 7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANRV CT" b2="100 KV" b3="BUS LN7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANRV CT" b2="18 KV" b3="ST 7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DANRV CT" b2="18 KV" b3="ST07" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101631</SeqNum>
    <Name>DanRiverCT.CT08 (DUKE)</Name>
    <LastEdit Timestamp="2025-08-14T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DANRV CT" b2="100 KV" b3="BK 8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANRV CT" b2="100 KV" b3="BUS LN8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANRV CT" b2="18 KV" b3="CT 8" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DANRV CT" b2="18 KV" b3="CT08" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101632</SeqNum>
    <Name>DanRiverCT.CT09 (DUKE)</Name>
    <LastEdit Timestamp="2025-08-14T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DANRV CT" b2="100 KV" b3="BK 9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANRV CT" b2="100 KV" b3="BUS L9R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANRV CT" b2="18 KV" b3="CT 9" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DANRV CT" b2="18 KV" b3="CT09" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101634</SeqNum>
    <Name>L138.WestMountVernon-Ashley</Name>
    <LastEdit Timestamp="2025-08-19T10:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHLEY 3" b2="138 KV" b3="1486" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MT VRNO3" b2="138 KV" b3="H31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MT VRNO3" b2="138 KV" b3="H33" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASHLEY 3" b2="138 KV" b3="LN  2646" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101635</SeqNum>
    <Name>L69.Vineland.0768(G10.SD)</Name>
    <LastEdit Timestamp="2025-08-22T11:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="VINELAND" b2="69 KV" b3="0768" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINELAND" b2="69 KV" b3="OCB C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINELAND" b2="69 KV" b3="OCB G" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101636</SeqNum>
    <Name>L69.Vineland.0712(G11.SD)</Name>
    <LastEdit Timestamp="2025-09-18T11:08:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="VINELAND" b2="69 KV" b3="0712" />
      <ContingencyEquipment Action="S" Type="SD" b1="VINELAND" b2="69 KV" b3="0712-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINELAND" b2="69 KV" b3="OCB J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINELAND" b2="69 KV" b3="OCB S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINELAND" b2="69 KV" b3="W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101637</SeqNum>
    <Name>L345.Cahokia-Beehive</Name>
    <LastEdit Timestamp="2025-08-14T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEHV" b2="345 KV" b3="V43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEHV" b2="345 KV" b3="V45" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEHV" b2="345 KV" b3="BEH-CAHO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAHOKIA3" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAHOKIA3" b2="345 KV" b3="V5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101638</SeqNum>
    <Name>L138.NorrisCity-Crossville</Name>
    <LastEdit Timestamp="2025-08-19T16:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSVL3" b2="138 KV" b3="H11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSVL3" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORRIS 3" b2="138 KV" b3="1771" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORRIS 3" b2="138 KV" b3="30439313" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101639</SeqNum>
    <Name>L230.Commodore-PNKY</Name>
    <LastEdit Timestamp="2026-03-26T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CMDR" b2="345 KV" b3="V7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CMDR" b2="345 KV" b3="V9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101640</SeqNum>
    <Name>L345.Ashtabula-Perry</Name>
    <LastEdit Timestamp="2026-04-17T08:31:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="345 KV" b3="B210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="345 KV" b3="B214" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRY_FE" b2="345 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="PERRY_FE" b2="345 KV" b3="PER-ASH1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101641</SeqNum>
    <Name>345/138.Ashtabula.TR9</Name>
    <LastEdit Timestamp="2025-10-14T09:59:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="138 KV" b3="B149" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="345 KV" b3="B213" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHTABUL" b2="345 KV" b3="B246" />
      <ContingencyEquipment Action="X" Type="XF" b1="ASHTABUL" b2="345 KV" b3="TR-9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101642</SeqNum>
    <Name>138/69.Rigis.TR1</Name>
    <LastEdit Timestamp="2025-08-14T10:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOODYEAR" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIGIS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOODYEAR" b2="69 KV" b3="GOO-RIG" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIGIS" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101643</SeqNum>
    <Name>L138.Gibson-OSWD</Name>
    <LastEdit Timestamp="2025-08-14T10:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON 3" b2="138 KV" b3="1522" />
      <ContingencyEquipment Action="L" Type="LN" b1="GIBSON 3" b2="138 KV" b3="GIB-OSWD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSWD" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OSWD" b2="138 KV" b3="H5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101644</SeqNum>
    <Name>L345.Root-EnonTP-Belleau</Name>
    <LastEdit Timestamp="2025-09-12T14:44:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELLEAU3" b2="345 KV" b3="BEL-ENON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEAU3" b2="345 KV" b3="V31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENON CNT" b2="345 KV" b3="302" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENON CNT" b2="345 KV" b3="ENO-ENO" />
      <ContingencyEquipment Action="L" Type="LN" b1="ENON TP" b2="345 KV" b3="ENO-ROOT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROOT" b2="345 KV" b3="V5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROOT" b2="345 KV" b3="V7" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROOT" b2="345 KV" b3="V8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101646</SeqNum>
    <Name>Rawlings.SV1</Name>
    <LastEdit Timestamp="2025-08-14T10:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="RAWLINGS" b2="500 KV" b3="1BOOST" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RAWLINGS" b2="500 KV" b3="1BUCK" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RAWLINGS" b2="500 KV" b3="SV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAWLINGS" b2="500 KV" b3="SV192" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101647</SeqNum>
    <Name>115/34.PequestRiver.BK2</Name>
    <LastEdit Timestamp="2026-03-03T10:41:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEQUESTR" b2="34 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEQUESTR" b2="115 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEQUESTR" b2="115 KV" b3="B8" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEQUESTR" b2="115 KV" b3="BK 2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PEQUESTR" b2="34 KV" b3="FOLRFTSP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEQUESTR" b2="34 KV" b3="LOAD1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PEQUESTR" b2="34 KV" b3="WARRENSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101648</SeqNum>
    <Name>L161.SouthGlasgow-Summershade (TVA)</Name>
    <LastEdit Timestamp="2025-08-19T10:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SGLASGOW" b2="161 KV" b3="1026" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SGLASGOW" b2="161 KV" b3="938" />
      <ContingencyEquipment Action="L" Type="LN" b1="SGLASGOW" b2="161 KV" b3="SGL-SUMM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMER" b2="161 KV" b3="934" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SUMMER" b2="161 KV" b3="939" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101649</SeqNum>
    <Name>L161.FoxHollow-SouthGlasgow (TVA) Tie</Name>
    <LastEdit Timestamp="2025-08-21T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="E_GLSGW" b2="161 KV" b3="EGL-EGL2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="E_GLSGW" b2="161 KV" b3="LD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="E_GLSTP" b2="161 KV" b3="EGL-SGLA" />
      <ContingencyEquipment Action="L" Type="LN" b1="E_GLSTP" b2="161 KV" b3="EGL-FOXH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOX_HOLL" b2="161 KV" b3="W18-1034" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SGLASGOW" b2="161 KV" b3="1026" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SGLASGOW" b2="161 KV" b3="924" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101650</SeqNum>
    <Name>500/138.Yukon.TR6</Name>
    <LastEdit Timestamp="2025-08-25T11:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="138 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="500 KV" b3="B170" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YUKON" b2="500 KV" b3="B175" />
      <ContingencyEquipment Action="X" Type="XF" b1="YUKON" b2="500 KV" b3="TR6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101651</SeqNum>
    <Name>L115.FtEustis-Grafton-Yorktown.34</Name>
    <LastEdit Timestamp="2025-08-19T16:39:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FTEUSTIS" b2="115 KV" b3="34T1038" />
      <ContingencyEquipment Action="L" Type="LN" b1="FTEUSTIS" b2="115 KV" b3="FTE-GRAF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FTEUSTIS" b2="115 KV" b3="H392" />
      <ContingencyEquipment Action="L" Type="LN" b1="YORKTOW4" b2="115 KV" b3="34D" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRAFTON4" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRAFTON4" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKTOW4" b2="115 KV" b3="3482" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101652</SeqNum>
    <Name>345/138.HardinCounty.T4</Name>
    <LastEdit Timestamp="2025-08-19T10:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="138 KV" b3="CB722" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="138 KV" b3="CB728" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="345 KV" b3="CB904" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="345 KV" b3="CB924" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="345 KV" b3="CB944" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARDIN_C" b2="345 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101653</SeqNum>
    <Name>138/69.HardinCounty.T3</Name>
    <LastEdit Timestamp="2025-08-19T10:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="69 KV" b3="618" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="138 KV" b3="CB712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="138 KV" b3="CB718" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARDIN_C" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101654</SeqNum>
    <Name>L69.Frackville-HighRidge</Name>
    <LastEdit Timestamp="2025-05-13T09:53:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="AUBU" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRACKVIL" b2="69 KV" b3="FRA-HIG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="MOW1AUBU" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HIGHR_PL" b2="69 KV" b3="2341" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIGHR_PL" b2="69 KV" b3="T1LOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIGHR_PL" b2="69 KV" b3="T2LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101657</SeqNum>
    <Name>L138.Highland-Magellan</Name>
    <LastEdit Timestamp="2025-08-19T10:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="B205" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="138 KV" b3="B208" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGELLAN" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAGELLAN" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLAOE" b2="138 KV" b3="HIG-MAGE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101658</SeqNum>
    <Name>230/115.NorthMeshoppen.4TX</Name>
    <LastEdit Timestamp="2024-10-29T16:35:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NMESHOPP" b2="230 KV" b3="4 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="115 KV" b3="B106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="115 KV" b3="B107" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="230 KV" b3="B22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="230 KV" b3="B25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101659</SeqNum>
    <Name>L138.Glidden-WDekalb.8315</Name>
    <LastEdit Timestamp="2025-10-10T13:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="375 W DE" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="375 W DE" b2="138 KV" b3="L8315CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="83 GLIDD" b2="138 KV" b3="BT5-6 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="83 GLIDD" b2="138 KV" b3="BT6-8 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="83 GLIDD" b2="138 KV" b3="GLI-WDEK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101661</SeqNum>
    <Name>L69.Peoria-Darby</Name>
    <LastEdit Timestamp="2025-08-19T10:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARBY" b2="69 KV" b3="CG-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEORIA" b2="69 KV" b3="CE-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEORIA" b2="69 KV" b3="CE-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARBY" b2="69 KV" b3="DAR-PEOR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101662</SeqNum>
    <Name>L69.Peoria-EastLibertyUnion-HndaLiberty-HndaMrsvil</Name>
    <LastEdit Timestamp="2026-05-11T09:23:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="6619REA" b2="69 KV" b3="661-ELI" />
      <ContingencyEquipment Action="L" Type="LN" b1="6619REA" b2="69 KV" b3="661-HON" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="6619REA" b2="69 KV" b3="ELIB1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="6619REA" b2="69 KV" b3="ELIB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIBERTY" b2="69 KV" b3="CH-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HONDAMAR" b2="69 KV" b3="B09" />
      <ContingencyEquipment Action="L" Type="LN" b1="6619REA" b2="69 KV" b3="661-PEOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEORIA" b2="69 KV" b3="CE-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEORIA" b2="69 KV" b3="CE-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101663</SeqNum>
    <Name>L345.Hazelton-Arnold</Name>
    <LastEdit Timestamp="2025-08-19T16:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARNOLD16" b2="345 KV" b3="0710" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARNOLD16" b2="345 KV" b3="4730" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAZLTON6" b2="345 KV" b3="62050625" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZLTON6" b2="345 KV" b3="997" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZLTON6" b2="345 KV" b3="9983" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101664</SeqNum>
    <Name>115/34.PequestRiver.BK1</Name>
    <LastEdit Timestamp="2026-03-03T10:41:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PEQUESTR" b2="34 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEQUESTR" b2="115 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEQUESTR" b2="115 KV" b3="B9" />
      <ContingencyEquipment Action="X" Type="XF" b1="PEQUESTR" b2="115 KV" b3="BK 1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PEQUESTR" b2="34 KV" b3="CAP1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PEQUESTR" b2="34 KV" b3="FOULRISP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEQUESTR" b2="34 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101665</SeqNum>
    <Name>L115.KerrDam-Bishop.137D</Name>
    <LastEdit Timestamp="2025-03-17T13:39:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP2" b2="115 KV" b3="13712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP2" b2="115 KV" b3="VT137" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERRDAM" b2="115 KV" b3="105" />
      <ContingencyEquipment Action="L" Type="LN" b1="BISHOP2" b2="115 KV" b3="BIS-KERR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101666</SeqNum>
    <Name>DTX230.Easters.LD1</Name>
    <LastEdit Timestamp="2024-06-10T19:15:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTERS" b2="230 KV" b3="LD1_V37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="V32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="VT2229" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101667</SeqNum>
    <Name>DTX230.Easters.LD2</Name>
    <LastEdit Timestamp="2024-06-10T19:16:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTERS" b2="230 KV" b3="LD2_W37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="W32" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="WT2226" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101669</SeqNum>
    <Name>L138.Bam-SprgVal (MISO)</Name>
    <LastEdit Timestamp="2025-08-19T16:40:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAM" b2="138 KV" b3="9191" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAM" b2="138 KV" b3="BAM-SPRG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRG VA3" b2="138 KV" b3="9172" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101671</SeqNum>
    <Name>DTX230.EvergreenMills.H437</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EVRGREEN" b2="230 KV" b3="H432" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EVRGREEN" b2="230 KV" b3="H437_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVRGREEN" b2="230 KV" b3="YTH4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101672</SeqNum>
    <Name>DTX230.EvergreenMills.H337</Name>
    <LastEdit Timestamp="2026-04-28T08:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EVRGREEN" b2="230 KV" b3="H332" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EVRGREEN" b2="230 KV" b3="H337_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EVRGREEN" b2="230 KV" b3="WTH3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101673</SeqNum>
    <Name>L69.Ontario-HarborBeach.0609</Name>
    <LastEdit Timestamp="2025-09-02T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBORBC" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBORBC" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARBORBC" b2="69 KV" b3="HAR-ONTA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONTARIO" b2="69 KV" b3="HP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101674</SeqNum>
    <Name>L69.HarborBeach-Huron.0610</Name>
    <LastEdit Timestamp="2025-09-04T13:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBORBC" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBORBC" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARBORBC" b2="69 KV" b3="HAR-HURO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HURON" b2="69 KV" b3="P CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HURON" b2="69 KV" b3="W CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101675</SeqNum>
    <Name>DTX69.HarborBeach.T1</Name>
    <LastEdit Timestamp="2025-09-02T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBORBC" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBORBC" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARBORBC" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101676</SeqNum>
    <Name>DTX69.HarborBeach.T2</Name>
    <LastEdit Timestamp="2025-09-02T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBORBC" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARBORBC" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARBORBC" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101677</SeqNum>
    <Name>DTX138.HummelCreek.T1 &amp; T2 &amp; LoadSwap</Name>
    <LastEdit Timestamp="2022-07-07T15:16:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELCR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELCR" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELCR" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOOVILLE" b2="138 KV" b3="DOO-HUM" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUMMELCR" b2="138 KV" b3="HUM-GRE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUMMELCR" b2="138 KV" b3="HUM-ROC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUMMELCR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUMMELCR" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MISSISSI" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101679</SeqNum>
    <Name>L230.Athenia-Harvey.Y-2330</Name>
    <LastEdit Timestamp="2025-08-21T12:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ATHENIA" b2="230 KV" b3="3-7" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATHENIA" b2="230 KV" b3="ATH-HARV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVEY" b2="230 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVEY" b2="230 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101680</SeqNum>
    <Name>138/69.EBeaver.TR1</Name>
    <LastEdit Timestamp="2025-12-11T15:15:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEAVER" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEAVER" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEAVER" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBEAVER" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="X" Type="XF" b1="EBEAVER" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101683</SeqNum>
    <Name>L138.Whitwat-LKHD-Sunrise (MISO)</Name>
    <LastEdit Timestamp="2025-11-17T11:44:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNTOWN" b2="138 KV" b3="7148" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LKHD TP3" b2="138 KV" b3="T1_LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LKHD TP3" b2="138 KV" b3="T2_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNRISE" b2="138 KV" b3="7236-S" />
      <ContingencyEquipment Action="L" Type="LN" b1="LKHD TP3" b2="138 KV" b3="LKH-SUNR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITWAT3" b2="138 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="WHITWAT3" b2="138 KV" b3="39523399" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101686</SeqNum>
    <Name>L230.Haymarket-Heathcote.2184A</Name>
    <LastEdit Timestamp="2026-01-16T13:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYMARKT" b2="230 KV" b3="H12T2184" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYMARKT" b2="230 KV" b3="H34T2184" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAYMARKT" b2="230 KV" b3="HAY-HEA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATHCOT" b2="230 KV" b3="218402" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATHCOT" b2="230 KV" b3="21842251" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101687</SeqNum>
    <Name>L230.Haymarket-Heathcote.2185A</Name>
    <LastEdit Timestamp="2025-08-29T13:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYMARKT" b2="230 KV" b3="H12T2185" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYMARKT" b2="230 KV" b3="H34T2185" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAYMARKT" b2="230 KV" b3="HAY-HEA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATHCOT" b2="230 KV" b3="21762185" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATHCOT" b2="230 KV" b3="218502" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101689</SeqNum>
    <Name>138/69/34.Jay.T4</Name>
    <LastEdit Timestamp="2025-08-29T12:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="JAY" b2="138 KV" b3="4-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="JAY" b2="69 KV" b3="4-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="JAY" b2="34 KV" b3="4-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JAY" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JAY" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JAY" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JAY" b2="69 KV" b3="K1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JAY" b2="34 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101690</SeqNum>
    <Name>L138.Canal-Gay</Name>
    <LastEdit Timestamp="2025-11-25T16:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CANALAEP" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANALAEP" b2="138 KV" b3="CAN-GAY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANALAEP" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAY" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAY" b2="138 KV" b3="102" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101698</SeqNum>
    <Name>Renan.SP</Name>
    <LastEdit Timestamp="2025-08-21T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RENAN" b2="69 KV" b3="52-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="RENAN" b2="69 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RENAN" b2="34.5 KV" b3="RENANSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101699</SeqNum>
    <Name>L345.Stuart-Clay</Name>
    <LastEdit Timestamp="2025-08-25T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAY" b2="345 KV" b3="HA-AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAY" b2="345 KV" b3="HA-CC" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAY" b2="345 KV" b3="CLA-STUA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUART2" b2="345 KV" b3="MM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUART2" b2="345 KV" b3="NN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101705</SeqNum>
    <Name>L345.Massac-Kelso (ILL/MISO)</Name>
    <LastEdit Timestamp="2024-06-10T15:23:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KELSO  3" b2="345 KV" b3="KEL-MASS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KELSO  3" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASSAC" b2="345 KV" b3="V31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASSAC" b2="345 KV" b3="V33" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101712</SeqNum>
    <Name>L345.Clay-HectateEnergyHighland</Name>
    <LastEdit Timestamp="2025-08-26T17:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLAY" b2="345 KV" b3="CLA-HECE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAY" b2="345 KV" b3="HA-BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAY" b2="345 KV" b3="HA-CC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEC_ENER" b2="345 KV" b3="TRAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101713</SeqNum>
    <Name>345/34.HectateEnergyHighland.TR12 + SP1 + SP2</Name>
    <LastEdit Timestamp="2025-08-26T17:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="HEC_ENER" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HEC_ENER" b2="34.5 KV" b3="GEN1SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HEC_ENER" b2="34.5 KV" b3="GEN2SP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEC_ENER" b2="345 KV" b3="TR12CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="HEC_ENER" b2="345 KV" b3="TR1_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101714</SeqNum>
    <Name>345/34.HectateEnergyHighland.TR3 + SP3</Name>
    <LastEdit Timestamp="2025-08-26T17:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="HEC_ENER" b2="34.5 KV" b3="CAP3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HEC_ENER" b2="34.5 KV" b3="GEN3SP" />
      <ContingencyEquipment Action="X" Type="XF" b1="HEC_ENER" b2="345 KV" b3="TR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEC_ENER" b2="345 KV" b3="TR3CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101715</SeqNum>
    <Name>345/34.HectateEnergyHighland.TR4 + SP4</Name>
    <LastEdit Timestamp="2025-08-26T17:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="HEC_ENER" b2="34.5 KV" b3="CAP4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HEC_ENER" b2="34.5 KV" b3="GEN4SP" />
      <ContingencyEquipment Action="X" Type="XF" b1="HEC_ENER" b2="345 KV" b3="TR4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEC_ENER" b2="345 KV" b3="TR4CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101716</SeqNum>
    <Name>230/69.Benning.12T</Name>
    <LastEdit Timestamp="2025-08-29T12:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BENNING" b2="230 KV" b3="12T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="1CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BENNING" b2="69 KV" b3="1CBB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENNING" b2="230 KV" b3="230-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="4AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="4BB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K5B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K7B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101719</SeqNum>
    <Name>L345.WestLexington-Brown</Name>
    <LastEdit Timestamp="2025-08-26T18:08:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_NO" b2="345 KV" b3="B152_912" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROWN_NO" b2="345 KV" b3="BRO-WLX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROWN_NO" b2="345 KV" b3="CB914" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W_LXNGT" b2="345 KV" b3="904" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101720</SeqNum>
    <Name>138/69.WestCanton.T2</Name>
    <LastEdit Timestamp="2025-08-29T12:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="JJ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="69 KV" b3="P" />
      <ContingencyEquipment Action="X" Type="XF" b1="WCANTON" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101722</SeqNum>
    <Name>230/115.HoggardMill.TX1</Name>
    <LastEdit Timestamp="2025-08-29T12:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOGARDML" b2="230 KV" b3="H122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOGARDML" b2="115 KV" b3="L1T1054" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOGARDML" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101723</SeqNum>
    <Name>230/115.HoggardMill.TX2</Name>
    <LastEdit Timestamp="2025-08-29T12:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOGARDML" b2="230 KV" b3="H222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOGARDML" b2="115 KV" b3="L2T1054" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOGARDML" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101724</SeqNum>
    <Name>DTX115.HoggardMill.WINDSRDP</Name>
    <LastEdit Timestamp="2025-08-29T12:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOGARDML" b2="115 KV" b3="L1T1054" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOGARDML" b2="115 KV" b3="L2T1054" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOGARDML" b2="115 KV" b3="WINDSRDP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101738</SeqNum>
    <Name>L138.CapitolHill-Chemical</Name>
    <LastEdit Timestamp="2025-08-29T12:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPITOLH" b2="138 KV" b3="U" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAPITOLH" b2="138 KV" b3="CAP-CHE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="138 KV" b3="T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101742</SeqNum>
    <Name>230/35.Idylwood.TX1Z</Name>
    <LastEdit Timestamp="2025-08-29T12:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IDYLWOO4" b2="230 KV" b3="H1Z12" />
      <ContingencyEquipment Action="X" Type="XF" b1="IDYLWOO4" b2="230 KV" b3="TX1Z" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="IDYLWOO4" b2="35 KV" b3="TX1Z" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101750</SeqNum>
    <Name>138/115.Edinburg.TX3</Name>
    <LastEdit Timestamp="2025-09-02T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDINBUR4" b2="138 KV" b3="H312" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDINBUR4" b2="115 KV" b3="L312" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDINBUR4" b2="138 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101751</SeqNum>
    <Name>TownSend.SP</Name>
    <LastEdit Timestamp="2025-09-03T14:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWNSEND" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWNSEND" b2="138 KV" b3="137" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TOWNSEND" b2="138 KV" b3="TOWNSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101752</SeqNum>
    <Name>L138.Sundial-LaceyBranch</Name>
    <LastEdit Timestamp="2025-09-03T09:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LACEYBRA" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="LACEYBRA" b2="138 KV" b3="LAC-SUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNDIAL" b2="138 KV" b3="P CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101753</SeqNum>
    <Name>L115.PequestRiver-Drakestown-Flanders</Name>
    <LastEdit Timestamp="2025-09-02T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DRAKESTO" b2="115 KV" b3="LD 1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLANDERS" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLANDERS" b2="34.5 KV" b3="BBK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DRAKESTO" b2="115 KV" b3="DRA-FLA" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FLANDERS" b2="115 KV" b3="NEM1JC" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLANDERS" b2="115 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEQUESTR" b2="115 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEQUESTR" b2="115 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="DRAKESTO" b2="115 KV" b3="DRA-PEQU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101754</SeqNum>
    <Name>L230.Glenbrook-SusquehannaT10</Name>
    <LastEdit Timestamp="2025-09-03T09:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="230 KV" b3="SU10_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="230 KV" b3="SU10_S" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENBROO" b2="230 KV" b3="GLE-SU10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQT10" b2="230 KV" b3="MONTNBUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQT10" b2="230 KV" b3="MONTSBUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101755</SeqNum>
    <Name>L230.Glenbrook-Susquehanna</Name>
    <LastEdit Timestamp="2025-09-03T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="230 KV" b3="MONTSUSQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="230 KV" b3="SUSQ" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENBROO" b2="230 KV" b3="GLE-SUSQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="MONT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="MONTPALO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101756</SeqNum>
    <Name>L115.BeechBranch-Heartsease-Hartsmill.1048</Name>
    <LastEdit Timestamp="2025-09-03T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BCHBRNCH" b2="115 KV" b3="104832" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BCHBRNCH" b2="115 KV" b3="80T1048" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARTSMIL" b2="115 KV" b3="104862" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARTSMIL" b2="115 KV" b3="55T1048" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARTSMIL" b2="115 KV" b3="HAR-HRTS" />
      <ContingencyEquipment Action="L" Type="LN" b1="BCHBRNCH" b2="115 KV" b3="BCH-HRTS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HRTSEASE" b2="115 KV" b3="DP1 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101757</SeqNum>
    <Name>230/69.Glenbrook.T1</Name>
    <LastEdit Timestamp="2025-09-03T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="GLENBROO" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="230 KV" b3="TRAN1HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="69 KV" b3="TRAN1LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101759</SeqNum>
    <Name>L345.939Mulberry-Tazewell.93915</Name>
    <LastEdit Timestamp="2026-01-20T17:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="939_MUL" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="939_MUL" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="939_MUL" b2="345 KV" b3="1-7" />
      <ContingencyEquipment Action="L" Type="LN" b1="939_MUL" b2="345 KV" b3="MUL-TAZE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWEL2" b2="345 KV" b3="V41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAZEWEL2" b2="345 KV" b3="V43" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101761</SeqNum>
    <Name>230/69.Glenbrook.T2</Name>
    <LastEdit Timestamp="2025-09-03T09:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="GLENBROO" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="230 KV" b3="TRAN2HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="69 KV" b3="TRAN2LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101762</SeqNum>
    <Name>L138.MiamiFort - MiamiforGT</Name>
    <LastEdit Timestamp="2025-09-03T14:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="824_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="826" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="138 KV" b3="919" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101763</SeqNum>
    <Name>L69.Cresskill-Closter.752</Name>
    <LastEdit Timestamp="2025-10-10T13:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOSTER" b2="69 KV" b3="2-28-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOSTER" b2="69 KV" b3="3-28-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOSTER" b2="69 KV" b3="CLO-CRE7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRESSKIL" b2="69 KV" b3="752-37" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101765</SeqNum>
    <Name>L138.Lockbourne-Harris</Name>
    <LastEdit Timestamp="2025-09-03T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISCS" b2="138 KV" b3="6C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISCS" b2="138 KV" b3="6E" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRISCS" b2="138 KV" b3="HAR-LOCK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKBOUR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKBOUR" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101766</SeqNum>
    <Name>L69.Glenbrook-Salem-Berwick.2</Name>
    <LastEdit Timestamp="2026-01-12T12:08:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BERWICK" b2="69 KV" b3="BER-SAL2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERWICK" b2="69 KV" b3="BER-WBE2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERWICK" b2="69 KV" b3="LOAD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="69 KV" b3="COLU2_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="69 KV" b3="COLU2_S" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SALEMPL" b2="69 KV" b3="4265" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENBROO" b2="69 KV" b3="GLE-SAL2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SCOTTPL" b2="69 KV" b3="4252" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WBERWICK" b2="69 KV" b3="4255" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WBERWICK" b2="69 KV" b3="WBER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WBERWICK" b2="69 KV" b3="WBER CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WBERWICK" b2="69 KV" b3="WBER LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101767</SeqNum>
    <Name>ThreeRivers.CC2 + L345.ThreeRivers-Mulberry.92404</Name>
    <LastEdit Timestamp="2025-12-01T13:43:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="924_TRIV" b2="22.5 KV" b3="GEN2_CC" />
      <ContingencyEquipment Action="X" Type="XF" b1="924_TRIV" b2="345 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="924_TRIV" b2="345 KV" b3="TR2CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="924_TRIV" b2="22.5 KV" b3="UAT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="939_MUL" b2="345 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="939_MUL" b2="345 KV" b3="7-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="939_MUL" b2="345 KV" b3="7-8" />
      <ContingencyEquipment Action="L" Type="LN" b1="924_TRIV" b2="345 KV" b3="TRI-MUL2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101768</SeqNum>
    <Name>ThreeRivers.CC1 + L345.ThreeRivers-Mulberry.92401</Name>
    <LastEdit Timestamp="2025-12-01T13:43:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="924_TRIV" b2="22.5 KV" b3="GEN1_CC" />
      <ContingencyEquipment Action="X" Type="XF" b1="924_TRIV" b2="345 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="924_TRIV" b2="345 KV" b3="TR1CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="924_TRIV" b2="22.5 KV" b3="UAT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="939_MUL" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="939_MUL" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="924_TRIV" b2="345 KV" b3="TRI-MUL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101770</SeqNum>
    <Name>230/69.MartinsCreek.TR22</Name>
    <LastEdit Timestamp="2025-09-03T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MARTINSC" b2="230 KV" b3="TR22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="TR22_HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="69 KV" b3="TR22_LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101771</SeqNum>
    <Name>L138.Lockbourne.SCentral.1</Name>
    <LastEdit Timestamp="2025-09-03T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKBOUR" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKBOUR" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LOCKBOUR" b2="138 KV" b3="CAPA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCENTRAL" b2="138 KV" b3="HVB1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOCKBOUR" b2="138 KV" b3="LOC-SCE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101772</SeqNum>
    <Name>L138.Lockbourne.SCentral.2</Name>
    <LastEdit Timestamp="2025-09-03T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKBOUR" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKBOUR" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCENTRAL" b2="138 KV" b3="HVB2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOCKBOUR" b2="138 KV" b3="LOC-SCE2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCENTRAL" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101773</SeqNum>
    <Name>L345.EastStoleRoad-StolleRd [NYISO]</Name>
    <LastEdit Timestamp="2025-09-03T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ESTOLLER" b2="345 KV" b3="2B3003" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESTOLLER" b2="345 KV" b3="2B3009" />
      <ContingencyEquipment Action="L" Type="LN" b1="ESTOLLER" b2="345 KV" b3="EST-STOL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STOLLERD" b2="345 KV" b3="2852" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101774</SeqNum>
    <Name>L138.Lockbourne.SCentral.3</Name>
    <LastEdit Timestamp="2025-09-03T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKBOUR" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKBOUR" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCENTRAL" b2="138 KV" b3="HVB3" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOCKBOUR" b2="138 KV" b3="LOC-SCE3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101779</SeqNum>
    <Name>L138.New Bourbon-StFrancois [ILL_EQ]</Name>
    <LastEdit Timestamp="2025-09-04T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="N BURBN3" b2="138 KV" b3="B109" />
      <ContingencyEquipment Action="L" Type="LN" b1="STFRANCS" b2="138 KV" b3="31305317" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STFRANCS" b2="138 KV" b3="H22" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101780</SeqNum>
    <Name>345/138.SilverGrove.T24</Name>
    <LastEdit Timestamp="2025-09-04T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERGR" b2="345 KV" b3="1416" />
      <ContingencyEquipment Action="X" Type="XF" b1="SILVERGR" b2="345 KV" b3="24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERGR" b2="138 KV" b3="813" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101782</SeqNum>
    <Name>L138.Bellard-Brim</Name>
    <LastEdit Timestamp="2025-09-04T14:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02BRIM" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02BRIM" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLARD" b2="138 KV" b3="BEL-BRIM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLARD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLARD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101783</SeqNum>
    <Name>138/69.Bellard.T1</Name>
    <LastEdit Timestamp="2025-09-04T14:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLARD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLARD" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLARD" b2="69 KV" b3="E2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLARD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101785</SeqNum>
    <Name>L138.Circleville-WestFall</Name>
    <LastEdit Timestamp="2026-01-23T09:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CIRCLEVI" b2="138 KV" b3="AG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CIRCLEVI" b2="138 KV" b3="AH" />
      <ContingencyEquipment Action="L" Type="LN" b1="CIRCLEVI" b2="138 KV" b3="CIR-WSTF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSTFALL" b2="138 KV" b3="H000A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSTFALL" b2="138 KV" b3="H000A8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101787</SeqNum>
    <Name>L138.Cyprus-WhiteRoad</Name>
    <LastEdit Timestamp="2024-12-19T17:21:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CYPRUS" b2="138 KV" b3="CYP-WHIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H016M2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H016M5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITERD" b2="138 KV" b3="H001B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITERD" b2="138 KV" b3="H001C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101788</SeqNum>
    <Name>L138.Cyprus-Canal</Name>
    <LastEdit Timestamp="2024-12-13T08:44:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CANALAEP" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANALAEP" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CANALAEP" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANALAEP" b2="138 KV" b3="CAN-CYPR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000E2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000E5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101790</SeqNum>
    <Name>L230.ParagonPark-SterlingPark.2081</Name>
    <LastEdit Timestamp="2025-09-12T10:34:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PARAGNPK" b2="230 KV" b3="20812206" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARAGNPK" b2="230 KV" b3="208132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERLNPK" b2="230 KV" b3="20812194" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STERLNPK" b2="230 KV" b3="H472CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="PARAGNPK" b2="230 KV" b3="PAR-STE1" />
      <ContingencyEquipment Action="X" Type="XF" b1="STERLNPK" b2="230 KV" b3="TX_4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STERLNPK" b2="35 KV" b3="TX_4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101791</SeqNum>
    <Name>L230.ParagonPark-Beaumeade.2206</Name>
    <LastEdit Timestamp="2025-09-11T14:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="220692" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="274T2206" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAUMEAD" b2="230 KV" b3="BEA-PARA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARAGNPK" b2="230 KV" b3="20812206" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARAGNPK" b2="230 KV" b3="220632" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101796</SeqNum>
    <Name>DTX230.Betzwood.LOAD2</Name>
    <LastEdit Timestamp="2025-09-29T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BETZWOOD" b2="230 KV" b3="635" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETZWOOD" b2="230 KV" b3="805 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BETZWOOD" b2="230 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101797</SeqNum>
    <Name>DTX230.UpperProvidence.T3 &amp; LOAD1 </Name>
    <LastEdit Timestamp="2025-10-01T16:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERPRO" b2="230 KV" b3="625" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERPRO" b2="230 KV" b3="785" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UPPERPRO" b2="230 KV" b3="LOAD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UPPERPRO" b2="230 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101798</SeqNum>
    <Name>DTX230.UpperProvidence.LOAD2</Name>
    <LastEdit Timestamp="2025-09-29T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERPRO" b2="230 KV" b3="725" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UPPERPRO" b2="230 KV" b3="785" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UPPERPRO" b2="230 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101799</SeqNum>
    <Name>DTX230.Richmond.5TR</Name>
    <LastEdit Timestamp="2025-09-29T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="230 KV" b3="185 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="230 KV" b3="285 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RICH PE" b2="230 KV" b3="5TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101800</SeqNum>
    <Name>69/13.12th&amp;Irving.T3</Name>
    <LastEdit Timestamp="2026-01-27T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="12THST" b2="69 KV" b3="K1-21B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="12THST" b2="69 KV" b3="K1-22B" />
      <ContingencyEquipment Action="X" Type="XF" b1="12THST" b2="69 KV" b3="T3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="12THST" b2="13.8 KV" b3="T3_LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101801</SeqNum>
    <Name>DTX230.Benning.230-1</Name>
    <LastEdit Timestamp="2025-09-29T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="1AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="1BB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENNING" b2="230 KV" b3="230-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101802</SeqNum>
    <Name>DTX230.Benning.230-2</Name>
    <LastEdit Timestamp="2025-09-29T10:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENNING" b2="230 KV" b3="230-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="2AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="230 KV" b3="2BB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101803</SeqNum>
    <Name>DTX69.Benning.LOAD47</Name>
    <LastEdit Timestamp="2025-09-29T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K7B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K9B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENNING" b2="69 KV" b3="LOAD47" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101804</SeqNum>
    <Name>DTX69.Benning.69115</Name>
    <LastEdit Timestamp="2025-09-29T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENNING" b2="69 KV" b3="69115" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K10B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K12B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101805</SeqNum>
    <Name>DTX69.Benning.69114</Name>
    <LastEdit Timestamp="2025-09-30T15:45:00" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="2CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BENNING" b2="69 KV" b3="2CBB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENNING" b2="69 KV" b3="69114" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K6B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K8B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101806</SeqNum>
    <Name>DTX69.Benning.LOAD46</Name>
    <LastEdit Timestamp="2025-09-30T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENNING" b2="69 KV" b3="69K3B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENNING" b2="69 KV" b3="LOAD46" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101807</SeqNum>
    <Name>DTX138.BuzzardPoint.T12</Name>
    <LastEdit Timestamp="2025-09-30T08:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUZZARD" b2="138 KV" b3="K3-43B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUZZARD" b2="138 KV" b3="K3-44B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUZZARD" b2="138 KV" b3="LOAD T12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101808</SeqNum>
    <Name>69/13.FTSlocum.T1</Name>
    <LastEdit Timestamp="2026-01-27T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FTSLOCUM" b2="69 KV" b3="K1-21B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FTSLOCUM" b2="69 KV" b3="K1-22B" />
      <ContingencyEquipment Action="X" Type="XF" b1="FTSLOCUM" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FTSLOCUM" b2="13.8 KV" b3="T1_LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101813</SeqNum>
    <Name>230/69.Pentagon.TX4</Name>
    <LastEdit Timestamp="2025-09-04T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="230 KV" b3="H422" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="69 KV" b3="L422" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENTAGON" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101814</SeqNum>
    <Name>230/69.Pentagon.TX3</Name>
    <LastEdit Timestamp="2025-09-04T14:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="230 KV" b3="H322" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="69 KV" b3="L322" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENTAGON" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101819</SeqNum>
    <Name>L230.MuddyRun-PeachBottom.220-07 + MuddyRun.U5-8</Name>
    <LastEdit Timestamp="2025-09-05T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MUDDYRN" b2="230 KV" b3="075 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MUDDYRN" b2="230 KV" b3="MR 3TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="MUDDYRN" b2="230 KV" b3="MR 4TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="MUDDYRN" b2="230 KV" b3="MUD-PEA7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT6" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT7" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MUDDYRN" b2="13 KV" b3="UNIT8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="230 KV" b3="175 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="230 KV" b3="475" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PEACHBOT" b2="230 KV" b3="4TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEACHBOT" b2="230 KV" b3="675 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101820</SeqNum>
    <Name>230/13.Post.3TR</Name>
    <LastEdit Timestamp="2025-09-05T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POST" b2="13 KV" b3="35" />
      <ContingencyEquipment Action="X" Type="XF" b1="POST" b2="230 KV" b3="3TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POST" b2="230 KV" b3="565" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POST" b2="230 KV" b3="695" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101821</SeqNum>
    <Name>230/13.Post.2TR</Name>
    <LastEdit Timestamp="2025-09-05T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POST" b2="13 KV" b3="25" />
      <ContingencyEquipment Action="X" Type="XF" b1="POST" b2="230 KV" b3="2TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POST" b2="230 KV" b3="785" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POST" b2="230 KV" b3="895" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101822</SeqNum>
    <Name>69/13.Tuna.TR1</Name>
    <LastEdit Timestamp="2025-09-08T09:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="69 KV" b3="150" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="69 KV" b3="160" />
      <ContingencyEquipment Action="X" Type="XF" b1="TUNA" b2="69 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="13 KV" b3="TR1L CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101823</SeqNum>
    <Name>69/13.Tuna.TR2</Name>
    <LastEdit Timestamp="2025-11-26T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="69 KV" b3="110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="69 KV" b3="120" />
      <ContingencyEquipment Action="X" Type="XF" b1="TUNA" b2="69 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="13 KV" b3="TR2L CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101824</SeqNum>
    <Name>69/13.Tuna.TR3</Name>
    <LastEdit Timestamp="2025-09-08T09:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="69 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="69 KV" b3="140" />
      <ContingencyEquipment Action="X" Type="XF" b1="TUNA" b2="69 KV" b3="TR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TUNA" b2="13 KV" b3="TR3L CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101826</SeqNum>
    <Name>L138.LaRue-Nwaldo-Windfall-Fulton-Hedding-WMTVerno</Name>
    <LastEdit Timestamp="2025-09-30T20:45:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FULTON" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HEDDINGR" b2="138 KV" b3="H00792" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEDDINGR" b2="138 KV" b3="HED-FUL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEDDINGR" b2="138 KV" b3="HED-MWB1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEDDINGR" b2="138 KV" b3="HED-WMT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARUE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARUE" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MWBLOOMF" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWALDO" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="LARUE" b2="138 KV" b3="LAR-NWAL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NWALDO" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="NWALDO" b2="138 KV" b3="XFMRT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WINDFALL" b2="138 KV" b3="FUL-WIN" />
      <ContingencyEquipment Action="L" Type="LN" b1="WINDFALL" b2="138 KV" b3="NWA-WIN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WINDFALL" b2="138 KV" b3="T-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMTVERNO" b2="138 KV" b3="H000V5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101827</SeqNum>
    <Name>DTX.LaRue.T1</Name>
    <LastEdit Timestamp="2025-09-08T09:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LARUE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARUE" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LARUE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101828</SeqNum>
    <Name>DTX138.Waverly.T1</Name>
    <LastEdit Timestamp="2025-09-30T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY2" b2="138 KV" b3="101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY2" b2="138 KV" b3="106" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAVERLY2" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101829</SeqNum>
    <Name>DTX138.Waverly.T3</Name>
    <LastEdit Timestamp="2025-09-30T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY2" b2="138 KV" b3="104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY2" b2="138 KV" b3="105" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WAVERLY2" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAVERLY2" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101830</SeqNum>
    <Name>DTX138.Waverly.T4</Name>
    <LastEdit Timestamp="2025-09-30T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY2" b2="138 KV" b3="106" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAVERLY2" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WAVERLY2" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101831</SeqNum>
    <Name>DTX138.WestCampus.OSU7LD</Name>
    <LastEdit Timestamp="2025-09-30T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WCAMPUS" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCAMPUS" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WCAMPUS" b2="138 KV" b3="OSU7 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101832</SeqNum>
    <Name>DTX138.WestCampus.OSU8LD</Name>
    <LastEdit Timestamp="2025-09-30T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WCAMPUS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCAMPUS" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WCAMPUS" b2="138 KV" b3="OSU8 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101833</SeqNum>
    <Name>DTX138.WestCampus.OSU9LD</Name>
    <LastEdit Timestamp="2025-09-30T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WCAMPUS" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCAMPUS" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WCAMPUS" b2="138 KV" b3="OSU9 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101834</SeqNum>
    <Name>DTX138.WilsonCS.T1</Name>
    <LastEdit Timestamp="2025-09-30T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONCS" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONCS" b2="138 KV" b3="4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILSONCS" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101835</SeqNum>
    <Name>DTX138.WilsonCS.T2</Name>
    <LastEdit Timestamp="2025-09-30T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONCS" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONCS" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILSONCS" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101836</SeqNum>
    <Name>DTX138.WilsonCS.T3</Name>
    <LastEdit Timestamp="2025-09-30T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONCS" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONCS" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WILSONCS" b2="138 KV" b3="CAP5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILSONCS" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101837</SeqNum>
    <Name>Kent.Dover.CC + Kent.6759SD</Name>
    <LastEdit Timestamp="2025-12-01T13:37:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="52-G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="52-G3" />
      <ContingencyEquipment Action="S" Type="SD" b1="KENT" b2="69 KV" b3="6759" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KENT" b2="13 KV" b3="DOVER1CT" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KENT" b2="13 KV" b3="DOVER2CT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="GENDUMMY" />
      <ContingencyEquipment Action="X" Type="XF" b1="KENT" b2="69 KV" b3="TR1" />
      <ContingencyEquipment Action="X" Type="XF" b1="KENT" b2="69 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHST" b2="69 KV" b3="3070" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHST" b2="69 KV" b3="3080" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NORTHST" b2="69 KV" b3="GF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101838</SeqNum>
    <Name>Kent.Dover.CT2</Name>
    <LastEdit Timestamp="2025-09-08T09:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="52-G3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KENT" b2="13 KV" b3="DOVER2CT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101839</SeqNum>
    <Name>L69.Cheswold-Kent.6768</Name>
    <LastEdit Timestamp="2025-09-08T09:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWOLD" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESWOLD" b2="69 KV" b3="CHE-KEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="7870" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="7890" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101840</SeqNum>
    <Name>L138.Steele-Easton.13712</Name>
    <LastEdit Timestamp="2025-09-08T09:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTON" b2="138 KV" b3="165" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTON" b2="138 KV" b3="EAS-STE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="138 KV" b3="8260" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101849</SeqNum>
    <Name>765/138.Greentown.T3</Name>
    <LastEdit Timestamp="2025-09-08T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="GREENTO2" b2="765 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="765 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENTO2" b2="765 KV" b3="N1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101850</SeqNum>
    <Name>Llanerch.138.Cap7-1</Name>
    <LastEdit Timestamp="2025-09-09T11:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="LLANERCH" b2="138 KV" b3="7-1CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="138 KV" b3="715 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101851</SeqNum>
    <Name>Cromby.230.Cap6-4</Name>
    <LastEdit Timestamp="2025-09-09T11:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="CROMBY" b2="230 KV" b3="6-4 CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="230 KV" b3="645 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101852</SeqNum>
    <Name>Cromby.230.Cap5-1</Name>
    <LastEdit Timestamp="2025-09-09T11:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="CROMBY" b2="230 KV" b3="5-1 CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="230 KV" b3="515 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101853</SeqNum>
    <Name>Perkiomen.138.Cap7-1</Name>
    <LastEdit Timestamp="2025-09-09T11:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PERKIOME" b2="138 KV" b3="715 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="PERKIOME" b2="138 KV" b3="CAP 7-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101854</SeqNum>
    <Name>Heaton.138.Cap8-1</Name>
    <LastEdit Timestamp="2025-09-09T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="HEATON" b2="138 KV" b3="8-1 CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="138 KV" b3="815 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101855</SeqNum>
    <Name>Warrington.230.Cap1</Name>
    <LastEdit Timestamp="2025-09-09T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="WARRINGT" b2="230 KV" b3="230CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINGT" b2="230 KV" b3="815" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101856</SeqNum>
    <Name>Planebrook.230.Cap8-1</Name>
    <LastEdit Timestamp="2025-09-09T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="PLANEBRO" b2="230 KV" b3="8-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLANEBRO" b2="230 KV" b3="805" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101857</SeqNum>
    <Name>Newlinville.230.Cap7-1</Name>
    <LastEdit Timestamp="2025-09-09T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="NEWLINVI" b2="230 KV" b3="7-1 CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWLINVI" b2="230 KV" b3="715 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101858</SeqNum>
    <Name>Heaton.230.Cap10-1</Name>
    <LastEdit Timestamp="2025-09-09T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="HEATON" b2="230 KV" b3="10-1 CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATON" b2="230 KV" b3="105 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101859</SeqNum>
    <Name>Elroy.500.Cap22-1</Name>
    <LastEdit Timestamp="2025-09-09T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="ELROY" b2="500 KV" b3="22-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROY" b2="500 KV" b3="225" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101860</SeqNum>
    <Name>Elroy.500.Cap20-1</Name>
    <LastEdit Timestamp="2025-09-08T09:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="ELROY" b2="500 KV" b3="20-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELROY" b2="500 KV" b3="205" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101861</SeqNum>
    <Name>Bradford.230.Cap4-1</Name>
    <LastEdit Timestamp="2026-03-27T10:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="BRADFORD" b2="230 KV" b3="4-1_CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADFORD" b2="230 KV" b3="415 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101862</SeqNum>
    <Name>Cromby.138.Cap1-1</Name>
    <LastEdit Timestamp="2025-09-09T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="CROMBY" b2="138 KV" b3="1-1 CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROMBY" b2="138 KV" b3="115" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101866</SeqNum>
    <Name>L230.Waterfront-Ritchie.23051</Name>
    <LastEdit Timestamp="2025-09-09T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="230 KV" b3="23051B" />
      <ContingencyEquipment Action="P" Type="XF" b1="WATERFRO" b2="230 KV" b3="1T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="3BCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="3CCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="RITCHIE" b2="230 KV" b3="RIT-WATE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101867</SeqNum>
    <Name>L230.Waterfront-BuzzardPoint.23172</Name>
    <LastEdit Timestamp="2026-01-16T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="P" Type="XF" b1="BUZZARD" b2="138 KV" b3="14T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUZZARD" b2="138 KV" b3="14TSBCB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BUZZARD" b2="230 KV" b3="23172SR" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUZZARD" b2="230 KV" b3="BUZ-WATE" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUZZARD" b2="230 KV" b3="STAB-14T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="2BCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="2CCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101873</SeqNum>
    <Name>L230.Wakeman-Airport-Cannon Branch.2148</Name>
    <LastEdit Timestamp="2024-07-11T14:11:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AIRPORT" b2="230 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANNONBR" b2="230 KV" b3="214822" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANNONBR" b2="230 KV" b3="21482225" />
      <ContingencyEquipment Action="L" Type="LN" b1="AIRPORT" b2="230 KV" b3="AIR-CANN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKEMN" b2="230 KV" b3="214812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKEMN" b2="230 KV" b3="21482179" />
      <ContingencyEquipment Action="L" Type="LN" b1="AIRPORT" b2="230 KV" b3="AIR-WAKE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101874</SeqNum>
    <Name>L230.Wakeman-Cloverhill.2179</Name>
    <LastEdit Timestamp="2026-05-14T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERHL" b2="230 KV" b3="217952-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVERHL" b2="230 KV" b3="217952-7" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOVERHL" b2="230 KV" b3="CLO-WAKE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKEMN" b2="230 KV" b3="21482179" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKEMN" b2="230 KV" b3="217912" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101875</SeqNum>
    <Name>230/69.MartinsCreek.TR23</Name>
    <LastEdit Timestamp="2025-09-09T11:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MARTINSC" b2="230 KV" b3="TR23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="TR23_HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="69 KV" b3="TR23_LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101876</SeqNum>
    <Name>L138.Ashland-Brookside</Name>
    <LastEdit Timestamp="2025-09-09T11:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ASHLAND" b2="138 KV" b3="ASH-BROO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHLAND" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHLAND" b2="138 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKSID" b2="138 KV" b3="B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101877</SeqNum>
    <Name>DTX.Ashland.T1</Name>
    <LastEdit Timestamp="2024-08-20T11:36:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHLAND" b2="69 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHLAND" b2="69 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHLAND" b2="138 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASHLAND" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="X" Type="XF" b1="ASHLAND" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101878</SeqNum>
    <Name>Vineland.CT11</Name>
    <LastEdit Timestamp="2025-09-18T12:24:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="VINELAND" b2="13.8 KV" b3="CTYVINEL" />
      <ContingencyEquipment Action="X" Type="XF" b1="VINELAND" b2="69 KV" b3="GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="VINELAND" b2="69 KV" b3="LDXFMR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VINELAND" b2="4 KV" b3="STLOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINELAND" b2="69 KV" b3="W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101879</SeqNum>
    <Name>138/12.Christiana.T1</Name>
    <LastEdit Timestamp="2025-09-09T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="12 KV" b3="1A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="12 KV" b3="1B CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHR138" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101880</SeqNum>
    <Name>138/12.Christiana.T2</Name>
    <LastEdit Timestamp="2025-09-09T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="12 KV" b3="2A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="12 KV" b3="2B CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHR138" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101881</SeqNum>
    <Name>138/12.Christiana.T3</Name>
    <LastEdit Timestamp="2025-09-09T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="12 KV" b3="3A CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHR138" b2="12 KV" b3="3B CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHR138" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101882</SeqNum>
    <Name>RedLion.REDLINFC</Name>
    <LastEdit Timestamp="2025-09-11T10:00:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="144" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="34.5 KV" b3="3801" />
      <ContingencyEquipment Action="X" Type="XF" b1="REDLION" b2="138 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDLION" b2="34.5 KV" b3="REDLINFC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101883</SeqNum>
    <Name>69/13.DelawareCity.T1 + DelawareCity.G1</Name>
    <LastEdit Timestamp="2025-09-16T15:56:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="13 KV" b3="1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="13 KV" b3="1C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="69 KV" b3="62 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="69 KV" b3="64 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA DPL" b2="13 KV" b3="G1" />
      <ContingencyEquipment Action="X" Type="XF" b1="DELA DPL" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101884</SeqNum>
    <Name>69/13.DelawareCity.T2 + DelawareCity.G2</Name>
    <LastEdit Timestamp="2025-09-16T15:56:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="13 KV" b3="2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="13 KV" b3="2C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="69 KV" b3="62 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="69 KV" b3="63 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA DPL" b2="13 KV" b3="G2" />
      <ContingencyEquipment Action="X" Type="XF" b1="DELA DPL" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101885</SeqNum>
    <Name>DelawareCity.G3</Name>
    <LastEdit Timestamp="2025-09-11T09:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="13 KV" b3="3A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="13 KV" b3="BT5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="13 KV" b3="T6A" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA DPL" b2="13 KV" b3="UNIT03" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101886</SeqNum>
    <Name>DelawareCity.G10</Name>
    <LastEdit Timestamp="2025-09-11T09:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="DELA DPL" b2="13 KV" b3="G10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DELA DPL" b2="13 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELA DPL" b2="13 KV" b3="T4A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101888</SeqNum>
    <Name>WestDPL.G1</Name>
    <LastEdit Timestamp="2025-09-11T10:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="12 KV" b3="BT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="12 KV" b3="BT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WESTDPL" b2="12 KV" b3="G1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101889</SeqNum>
    <Name>BelleHaven.SVC</Name>
    <LastEdit Timestamp="2025-09-09T11:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="BELLEHAV" b2="12 KV" b3="D-SMES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLEHAV" b2="12 KV" b3="SMES CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101890</SeqNum>
    <Name>L230.Beco-ParagonPark.2207</Name>
    <LastEdit Timestamp="2025-10-30T15:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BECO" b2="230 KV" b3="220712" />
      <ContingencyEquipment Action="L" Type="LN" b1="BECO" b2="230 KV" b3="BEC-PARA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECO" b2="230 KV" b3="H12T2207" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARAGNPK" b2="230 KV" b3="21502207" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARAGNPK" b2="230 KV" b3="220732" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101891</SeqNum>
    <Name>DTX138.Robinsonville.T1</Name>
    <LastEdit Timestamp="2025-11-26T11:11:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBINS" b2="138 KV" b3="1301" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="ROBINS" b2="138 KV" b3="T1 LOAD" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="ROBINS" b2="138 KV" b3="T1 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101892</SeqNum>
    <Name>69/35.Eagle.2TR</Name>
    <LastEdit Timestamp="2025-09-11T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLE PE" b2="69 KV" b3="045" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLE PE" b2="35 KV" b3="25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLE PE" b2="69 KV" b3="785" />
      <ContingencyEquipment Action="X" Type="XF" b1="EAGLE PE" b2="69 KV" b3="EAGL2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101893</SeqNum>
    <Name>69/35.Eagle.1TR</Name>
    <LastEdit Timestamp="2025-09-11T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLE PE" b2="69 KV" b3="035" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLE PE" b2="35 KV" b3="15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EAGLE PE" b2="69 KV" b3="785" />
      <ContingencyEquipment Action="X" Type="XF" b1="EAGLE PE" b2="69 KV" b3="EAGL1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101894</SeqNum>
    <Name>FordMill.1STM</Name>
    <LastEdit Timestamp="2025-09-11T09:48:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FORDMILL" b2="230 KV" b3="1ST HICB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORDMILL" b2="18 KV" b3="1ST LOCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FORDMILL" b2="230 KV" b3="1STM XF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FORDMILL" b2="18 KV" b3="FE 1STM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101895</SeqNum>
    <Name>FordMill.2STM</Name>
    <LastEdit Timestamp="2025-09-11T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FORDMILL" b2="230 KV" b3="2ST HICB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORDMILL" b2="18 KV" b3="2ST LOCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FORDMILL" b2="230 KV" b3="2STM XF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FORDMILL" b2="18 KV" b3="FE 2STM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101896</SeqNum>
    <Name>L69.Amtrak-Richmond.6661</Name>
    <LastEdit Timestamp="2025-09-11T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMTRAK" b2="69 KV" b3="71 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMTRAK" b2="69 KV" b3="AMT-RIC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="69 KV" b3="110 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICH PE" b2="69 KV" b3="120 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101897</SeqNum>
    <Name>138/13.Bluegrass.1TR+4TR</Name>
    <LastEdit Timestamp="2025-09-11T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEGRAS" b2="13 KV" b3="1TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEGRAS" b2="138 KV" b3="335 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEGRAS" b2="13 KV" b3="4TRLS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEGRAS" b2="138 KV" b3="705 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUEGRAS" b2="138 KV" b3="BLU 1TR" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUEGRAS" b2="138 KV" b3="BLU 4TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101899</SeqNum>
    <Name>L138.Eddystone.BusTie.EDDYSTN</Name>
    <LastEdit Timestamp="2025-09-11T09:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="138 KV" b3="125 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDDYSTON" b2="138 KV" b3="215 CB" />
      <ContingencyEquipment Action="S" Type="SD" b1="EDDYSTON" b2="138 KV" b3="EDDYSTN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101900</SeqNum>
    <Name>230/69.Harvey.T220-1</Name>
    <LastEdit Timestamp="2025-09-11T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVEY" b2="69 KV" b3="1-9" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARVEY" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVEY" b2="230 KV" b3="220-1HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVEY" b2="69 KV" b3="9-10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101901</SeqNum>
    <Name>230/69.Harvey.T220-2</Name>
    <LastEdit Timestamp="2025-09-11T09:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVEY" b2="69 KV" b3="1-7" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARVEY" b2="230 KV" b3="220-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVEY" b2="230 KV" b3="220-2HS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVEY" b2="69 KV" b3="7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101902</SeqNum>
    <Name>L345.Killdeer-Quinn (MISO North)</Name>
    <LastEdit Timestamp="2025-09-12T10:38:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KILLDEER" b2="345 KV" b3="3820" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KILLDEER" b2="345 KV" b3="3822" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KILLDEER" b2="345 KV" b3="3827" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="KILLDEER" b2="345 KV" b3="C1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="KILLDEER" b2="345 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KILLDEER" b2="345 KV" b3="KIL-QUIN" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="KILLDEER" b2="345 KV" b3="R1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINN" b2="345 KV" b3="3763" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUINN" b2="345 KV" b3="3764" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101903</SeqNum>
    <Name>L161.Genoa-Seneca(WEST EQ)</Name>
    <LastEdit Timestamp="2025-09-11T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GENOA536" b2="161 KV" b3="2QB2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GENOA536" b2="161 KV" b3="2QY2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GENOA536" b2="161 KV" b3="LN  4398" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SENECA 6" b2="161 KV" b3="50QB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SENECA 6" b2="161 KV" b3="50QB2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101906</SeqNum>
    <Name>L115.LickRun-Arnold-Bigby</Name>
    <LastEdit Timestamp="2025-09-12T10:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARNOLDRE" b2="115 KV" b3="1BANK CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARNOLDRE" b2="115 KV" b3="ARN-BIG" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARNOLDRE" b2="115 KV" b3="ARN-LIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARNOLDRE" b2="115 KV" b3="GM CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGBY" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGBY" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICKRUN" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICKRUN" b2="115 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101907</SeqNum>
    <Name>L115.Bigby-MeyersdaleNorth</Name>
    <LastEdit Timestamp="2025-09-12T10:33:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGBY" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGBY" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIGBY" b2="115 KV" b3="BIG-MEY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEYERSDA" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MEYERSDA" b2="115 KV" b3="NO1 TX" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101908</SeqNum>
    <Name>Bigby.Lookout.WF</Name>
    <LastEdit Timestamp="2025-09-12T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIGBY" b2="115 KV" b3="B4WINDCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="BIGBY" b2="115 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BIGBY" b2="25 KV" b3="LOKOUTWF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101909</SeqNum>
    <Name>Arnold.GreenMountain.BT</Name>
    <LastEdit Timestamp="2025-09-12T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARNOLDRE" b2="115 KV" b3="GM CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ARNOLDRE" b2="115 KV" b3="GM TRAN" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ARNOLDRE" b2="25 KV" b3="GRENMTBS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101910</SeqNum>
    <Name>MeyersdaleNorth.BT</Name>
    <LastEdit Timestamp="2025-09-12T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEYERSDA" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEYERSDA" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEYERSDA" b2="34.5 KV" b3="MEYERSBS" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEYERSDA" b2="115 KV" b3="TXB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101911</SeqNum>
    <Name>MeyersdaleNorth.WF</Name>
    <LastEdit Timestamp="2025-09-12T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEYERSDA" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEYERSDA" b2="115 KV" b3="TXWF1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEYERSDA" b2="35 KV" b3="WINDPWR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101914</SeqNum>
    <Name>Cardiff.230.Cap1</Name>
    <LastEdit Timestamp="2025-09-12T10:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="CARDIFF" b2="230 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="CU CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101915</SeqNum>
    <Name>Cardiff.230.CapSVC</Name>
    <LastEdit Timestamp="2025-09-12T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARDIFF" b2="230 KV" b3="ES CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CARDIFF" b2="230 KV" b3="SVC CAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101916</SeqNum>
    <Name>England.138.Cap1</Name>
    <LastEdit Timestamp="2025-09-12T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-N" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ENGLAND" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101917</SeqNum>
    <Name>England.138.Cap2</Name>
    <LastEdit Timestamp="2025-09-12T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENGLAND" b2="138 KV" b3="452-L" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ENGLAND" b2="138 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101918</SeqNum>
    <Name>Mickleton.230.ReactorSR1</Name>
    <LastEdit Timestamp="2025-09-12T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MICKLETO" b2="230 KV" b3="GG" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MICKLETO" b2="230 KV" b3="SR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101919</SeqNum>
    <Name>ChapelStreet.138.Cap.2A&amp;2B</Name>
    <LastEdit Timestamp="2025-12-24T10:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAPELST" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHAPELST" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CHAPELST" b2="138 KV" b3="CAP2A" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CHAPELST" b2="138 KV" b3="CAP2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101920</SeqNum>
    <Name>Harmony.138.Cap1</Name>
    <LastEdit Timestamp="2025-09-12T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONY" b2="138 KV" b3="142" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HARMONY" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101921</SeqNum>
    <Name>Keeney.138.Cap1</Name>
    <LastEdit Timestamp="2025-09-12T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="138" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="KEENEY" b2="138 KV" b3="CAP1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101922</SeqNum>
    <Name>Kiamensi.138.Cap2</Name>
    <LastEdit Timestamp="2025-09-12T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KIAMENSI" b2="138 KV" b3="143" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="KIAMENSI" b2="138 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101923</SeqNum>
    <Name>MTPleasant.138.Cap.2&amp;3</Name>
    <LastEdit Timestamp="2025-09-12T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MTPLEASN" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTPLEASN" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MTPLEASN" b2="138 KV" b3="CAP 2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MTPLEASN" b2="138 KV" b3="CAP 3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101924</SeqNum>
    <Name>Bethany.138.Cap.2&amp;3</Name>
    <LastEdit Timestamp="2025-09-16T11:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="BETHANY" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BETHANY" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="138 KV" b3="CS-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BETHANY" b2="138 KV" b3="CS-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101925</SeqNum>
    <Name>Cheswold.138.Cap.1&amp;2</Name>
    <LastEdit Timestamp="2025-09-12T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWOLD" b2="138 KV" b3="130 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESWOLD" b2="138 KV" b3="8220" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CHESWOLD" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CHESWOLD" b2="138 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101926</SeqNum>
    <Name>Church.138.Cap.1&amp;2</Name>
    <LastEdit Timestamp="2025-09-12T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CHURCH" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CHURCH" b2="138 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101927</SeqNum>
    <Name>Felton.138.Cap.1&amp;2</Name>
    <LastEdit Timestamp="2025-09-12T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FELTON" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FELTON" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FELTON" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FELTON" b2="138 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101928</SeqNum>
    <Name>NorthSeaford.138.Cap.3&amp;4</Name>
    <LastEdit Timestamp="2025-09-16T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NSEAFORD" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NSEAFORD" b2="138 KV" b3="CAP4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101929</SeqNum>
    <Name>Vienna.138.Cap2</Name>
    <LastEdit Timestamp="2025-09-16T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VIENNA" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="VIENNA" b2="138 KV" b3="CAP2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101930</SeqNum>
    <Name>Wyemills.138.Cap.3&amp;4</Name>
    <LastEdit Timestamp="2025-09-16T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="138 KV" b3="130 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WYEMILLS" b2="138 KV" b3="131 CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WYEMILLS" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WYEMILLS" b2="138 KV" b3="CAP4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101931</SeqNum>
    <Name>CedarCreek.230.ReactorREAC</Name>
    <LastEdit Timestamp="2025-09-12T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCRE" b2="230 KV" b3="235" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CEDARCRE" b2="230 KV" b3="REAC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101932</SeqNum>
    <Name>NewCastle.138.ReactorSR1</Name>
    <LastEdit Timestamp="2025-09-12T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="138 KV" b3="137" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NEWCASTL" b2="138 KV" b3="SR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101933</SeqNum>
    <Name>DTX69.Kent.T2(LX)</Name>
    <LastEdit Timestamp="2025-09-16T11:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="7840" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="7850" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="KENT" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="KENT" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101934</SeqNum>
    <Name>DTX69.Harrington.VERNON(LX)</Name>
    <LastEdit Timestamp="2025-09-16T11:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRTN" b2="69 KV" b3="7240" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRTN" b2="69 KV" b3="7250" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="HARRTN" b2="69 KV" b3="VERNON" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="HARRTN" b2="69 KV" b3="VERNON" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101941</SeqNum>
    <Name>DTX345.Bayonne.T20</Name>
    <LastEdit Timestamp="2025-10-07T10:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="345 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYONNE" b2="345 KV" b3="5-6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BAYONNE" b2="345 KV" b3="T-20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101942</SeqNum>
    <Name>DTX345.Bayway.T345-3</Name>
    <LastEdit Timestamp="2025-10-07T10:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="3-11" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BAYWAY" b2="345 KV" b3="345-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101943</SeqNum>
    <Name>DTX345.Bayway.T345-1</Name>
    <LastEdit Timestamp="2025-10-07T10:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="1-5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BAYWAY" b2="345 KV" b3="345-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAYWAY" b2="345 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101944</SeqNum>
    <Name>DTX230.Bergen.T13KV-3</Name>
    <LastEdit Timestamp="2025-10-07T10:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERGEN" b2="230 KV" b3="13KV-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="23-24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="5-23" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101945</SeqNum>
    <Name>DTX69.BasinRoad.T1</Name>
    <LastEdit Timestamp="2025-10-07T10:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="69 KV" b3="68" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BASINRD" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101946</SeqNum>
    <Name>DTX230.Bergen.T13KV-1</Name>
    <LastEdit Timestamp="2025-10-07T10:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERGEN" b2="230 KV" b3="13KV-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="21-22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="5-21" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101947</SeqNum>
    <Name>DTX69.SilversideRoad.T2</Name>
    <LastEdit Timestamp="2026-02-10T08:47:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERSI" b2="69 KV" b3="65" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERSI" b2="69 KV" b3="68" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SILVERSI" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101948</SeqNum>
    <Name>DTX69.SilversideRoad.T1</Name>
    <LastEdit Timestamp="2025-10-07T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERSI" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERSI" b2="69 KV" b3="67" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SILVERSI" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101949</SeqNum>
    <Name>DTX69.SilversideRoad.T3</Name>
    <LastEdit Timestamp="2025-10-07T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERSI" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERSI" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SILVERSI" b2="69 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101950</SeqNum>
    <Name>DTX69/12.WestDPL.T3</Name>
    <LastEdit Timestamp="2025-12-03T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="69 KV" b3="62 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="69 KV" b3="68 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WESTDPL" b2="69 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="12 KV" b3="T3 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101951</SeqNum>
    <Name>DTX69/12.WestDPL.T1</Name>
    <LastEdit Timestamp="2025-12-03T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="69 KV" b3="61 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="69 KV" b3="65 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WESTDPL" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTDPL" b2="12 KV" b3="T1 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101952</SeqNum>
    <Name>DTX69.Kent.T1</Name>
    <LastEdit Timestamp="2025-10-07T10:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="7810" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENT" b2="69 KV" b3="7820" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KENT" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101953</SeqNum>
    <Name>DTX69.NorthSeaford.T3</Name>
    <LastEdit Timestamp="2025-10-07T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="69 KV" b3="7310" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSEAFORD" b2="69 KV" b3="7320" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NSEAFORD" b2="69 KV" b3="LOADT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101954</SeqNum>
    <Name>DTX69.Midway.T1</Name>
    <LastEdit Timestamp="2025-10-07T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAY" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAY" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDWAY" b2="69 KV" b3="T1 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101955</SeqNum>
    <Name>DTX69.Midway.T2</Name>
    <LastEdit Timestamp="2025-10-07T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAY" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAY" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDWAY" b2="69 KV" b3="T2 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101956</SeqNum>
    <Name>DTX69.Hebron.T1</Name>
    <LastEdit Timestamp="2025-10-07T10:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRON" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRON" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HEBRON" b2="69 KV" b3="LOAD 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101957</SeqNum>
    <Name>DTX69.Hebron.T2</Name>
    <LastEdit Timestamp="2025-10-07T10:20:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRON" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEBRON" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HEBRON" b2="69 KV" b3="LOAD 2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101958</SeqNum>
    <Name>DTX69.Lynch.T1</Name>
    <LastEdit Timestamp="2025-10-07T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNCH" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNCH" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LYNCH" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101959</SeqNum>
    <Name>DTX69.Lynch.T2</Name>
    <LastEdit Timestamp="2024-11-06T12:51:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNCH" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYNCH" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LYNCH" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101960</SeqNum>
    <Name>DTX69.Edgemoor.T7</Name>
    <LastEdit Timestamp="2025-10-07T10:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="69 KV" b3="1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDGEMOOR" b2="69 KV" b3="2-3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDGEMOOR" b2="69 KV" b3="T7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101961</SeqNum>
    <Name>DTX69.Monsanto.T1</Name>
    <LastEdit Timestamp="2025-10-07T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONSANTO" b2="69 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONSANTO" b2="69 KV" b3="OCB A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONSANTO" b2="69 KV" b3="OCB B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101962</SeqNum>
    <Name>DTX69.Oldman.T1</Name>
    <LastEdit Timestamp="2025-10-07T10:26:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OLDMAN" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLDMAN" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="OLDMAN" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OLDMAN" b2="69 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101963</SeqNum>
    <Name>DTX69.Paulsboro.T5</Name>
    <LastEdit Timestamp="2025-10-07T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PAULSBRO" b2="69 KV" b3="BUSOCB N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAULSBRO" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PAULSBRO" b2="69 KV" b3="LOAD5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAULSBRO" b2="69 KV" b3="OCB O" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101964</SeqNum>
    <Name>Dennis.230.CapDENN</Name>
    <LastEdit Timestamp="2025-10-02T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="DENNIS" b2="230 KV" b3="DENN CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNIS" b2="230 KV" b3="GCB B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101965</SeqNum>
    <Name>Carrcroft.138.Cap.1&amp;2</Name>
    <LastEdit Timestamp="2025-12-24T10:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CARRCROF" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARRCROF" b2="138 KV" b3="140" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CARRCROF" b2="138 KV" b3="CAP2A" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="CARRCROF" b2="138 KV" b3="CAP2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101966</SeqNum>
    <Name>Townsend.138.Cap.1&amp;2</Name>
    <LastEdit Timestamp="2025-10-02T10:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWNSEND" b2="138 KV" b3="137" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOWNSEND" b2="138 KV" b3="138" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="TOWNSEND" b2="138 KV" b3="CAP 1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="TOWNSEND" b2="138 KV" b3="CAP 2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TOWNSEND" b2="138 KV" b3="DUM1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101967</SeqNum>
    <Name>DTX69.Williams.T4 &amp; T5</Name>
    <LastEdit Timestamp="2025-10-07T10:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLIAMS" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLIAMS" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILLIAMS" b2="69 KV" b3="T4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILLIAMS" b2="69 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101968</SeqNum>
    <Name>DTX25.Todd.T1</Name>
    <LastEdit Timestamp="2025-10-07T10:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TODD" b2="69 KV" b3="7330" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODD" b2="69 KV" b3="7360" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TODD" b2="25 KV" b3="DORCHSP2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TODD" b2="25 KV" b3="LOAD_T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="TODD" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101969</SeqNum>
    <Name>DTX25.Todd.T2 &amp; T3</Name>
    <LastEdit Timestamp="2025-10-07T10:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TODD" b2="69 KV" b3="7340" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODD" b2="69 KV" b3="7350" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TODD" b2="25 KV" b3="DORCHSP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TODD" b2="25 KV" b3="LOADT2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TODD" b2="69 KV" b3="LOADT3" />
      <ContingencyEquipment Action="X" Type="XF" b1="TODD" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101970</SeqNum>
    <Name>L138.Carville-Pondtown.13723</Name>
    <LastEdit Timestamp="2026-02-09T10:41:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARVILLE" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARVILLE" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARVILLE" b2="138 KV" b3="CAR-PND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PONDTOWN" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PONDTOWN" b2="138 KV" b3="131" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101971</SeqNum>
    <Name>L138.Church-Pondtown.13735</Name>
    <LastEdit Timestamp="2026-02-09T10:41:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCH" b2="138 KV" b3="CHU-PND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PONDTOWN" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PONDTOWN" b2="138 KV" b3="133" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101972</SeqNum>
    <Name>L138.StoneBranch-MidKiff-Sheridan</Name>
    <LastEdit Timestamp="2025-11-20T13:51:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MIDKIFF" b2="138 KV" b3="MID-STON" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDKIFF" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDKIFF" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERIDAN" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDKIFF" b2="138 KV" b3="MID-SHER" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STONEBRA" b2="138 KV" b3="LX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STONEBRA" b2="138 KV" b3="LX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101973</SeqNum>
    <Name>L138.Eastwood-HalfAcre</Name>
    <LastEdit Timestamp="2025-10-16T13:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTWOOD" b2="138 KV" b3="859" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HALFACRE" b2="138 KV" b3="885" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTWOOD" b2="138 KV" b3="EAS-HALF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101974</SeqNum>
    <Name>L138.FordBatavia-HalfAcre</Name>
    <LastEdit Timestamp="2025-10-16T13:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FORD_BAT" b2="138 KV" b3="920" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORD_BAT" b2="138 KV" b3="936" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FORD_BAT" b2="138 KV" b3="LD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HALFACRE" b2="138 KV" b3="883" />
      <ContingencyEquipment Action="L" Type="LN" b1="FORD_BAT" b2="138 KV" b3="FRD-HALF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101975</SeqNum>
    <Name>69/13.Koonsville.TR1</Name>
    <LastEdit Timestamp="2025-10-17T12:06:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KOONSVIL" b2="69 KV" b3="66320" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KOONSVIL" b2="69 KV" b3="66376" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KOONSVIL" b2="13 KV" b3="LOAD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="KOONSVIL" b2="69 KV" b3="XFMR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101976</SeqNum>
    <Name>69/13.Koonsville.TR2</Name>
    <LastEdit Timestamp="2025-10-17T12:06:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KOONSVIL" b2="69 KV" b3="66320" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KOONSVIL" b2="69 KV" b3="66380" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KOONSVIL" b2="13 KV" b3="LOAD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="KOONSVIL" b2="69 KV" b3="XFMR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101978</SeqNum>
    <Name>230/35.Winterpock.TX2 &amp; TX3</Name>
    <LastEdit Timestamp="2025-10-06T11:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERPK" b2="230 KV" b3="H23T2066" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERPK" b2="230 KV" b3="H23T219" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERPK" b2="230 KV" b3="H252" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERPK" b2="230 KV" b3="H352" />
      <ContingencyEquipment Action="X" Type="XF" b1="WINTERPK" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WINTERPK" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="WINTERPK" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WINTERPK" b2="36.5 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101981</SeqNum>
    <Name>DTX138.BuzzardPoint.T11</Name>
    <LastEdit Timestamp="2025-10-07T10:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUZZARD" b2="138 KV" b3="K1-21B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUZZARD" b2="138 KV" b3="K1-22B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUZZARD" b2="138 KV" b3="LOAD T11" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BUZZARD" b2="138 KV" b3="NEM1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101982</SeqNum>
    <Name>DTX230.Morgantown.RSST1</Name>
    <LastEdit Timestamp="2025-10-07T10:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="9AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="9BB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MORGANTO" b2="230 KV" b3="RSST1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101983</SeqNum>
    <Name>DTX69.PotomacRiver.LD1</Name>
    <LastEdit Timestamp="2025-10-07T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="69K1-2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="69K1-6B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="6TSB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="POTOMAC" b2="69 KV" b3="GSA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POTOMAC" b2="69 KV" b3="LD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101984</SeqNum>
    <Name>DTX230.Morgantown.RSST2</Name>
    <LastEdit Timestamp="2025-10-07T10:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="8AB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORGANTO" b2="230 KV" b3="8BB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MORGANTO" b2="230 KV" b3="RSST2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101985</SeqNum>
    <Name>DTX69.PotomacRiver.LD6</Name>
    <LastEdit Timestamp="2025-10-07T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="69K1-6B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="69K5-6B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="7TSB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="POTOMAC" b2="69 KV" b3="GSA2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POTOMAC" b2="69 KV" b3="LD6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101986</SeqNum>
    <Name>DTX69.PotomacRiver.LD4</Name>
    <LastEdit Timestamp="2025-10-07T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="POTOMAC" b2="69 KV" b3="069-41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="5G4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="69K3-4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="69K4-5B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="9TSB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POTOMAC" b2="69 KV" b3="LD4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101987</SeqNum>
    <Name>DTX69.PotomacRiver.LD3</Name>
    <LastEdit Timestamp="2025-10-07T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="POTOMAC" b2="69 KV" b3="069-31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="5G3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="69K2-3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="69K3-4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="8TSB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POTOMAC" b2="69 KV" b3="LD3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101988</SeqNum>
    <Name>DTX69.PotomacRiver.LD2</Name>
    <LastEdit Timestamp="2025-10-07T10:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="69K1-2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="69K2-3B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POTOMAC" b2="69 KV" b3="LD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101989</SeqNum>
    <Name>DTX69.PotomacRiver.LD5</Name>
    <LastEdit Timestamp="2025-10-07T10:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="69K4-5B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTOMAC" b2="69 KV" b3="69K5-6B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POTOMAC" b2="69 KV" b3="LD5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101991</SeqNum>
    <Name>DTX69.Harwood.VALMLD</Name>
    <LastEdit Timestamp="2026-05-12T09:55:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="69 KV" b3="VALM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARWOOD" b2="69 KV" b3="VALMBAY6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARWOOD" b2="69 KV" b3="VALMLD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101992</SeqNum>
    <Name>DTX69.Jenkins.SCRANTN2</Name>
    <LastEdit Timestamp="2025-10-07T10:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="SCRA2_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="SCRA2_S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JENKINS" b2="69 KV" b3="SCRANTN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101993</SeqNum>
    <Name>DTX69.Jenkins.RIVER1</Name>
    <LastEdit Timestamp="2025-10-07T10:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="GEOR1_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="GEOR1_S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JENKINS" b2="69 KV" b3="RIVER1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101994</SeqNum>
    <Name>DTX69.Jenkins.RIVER2</Name>
    <LastEdit Timestamp="2025-10-07T10:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="GEOR2_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="GEOR2_S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JENKINS" b2="69 KV" b3="RIVER2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101995</SeqNum>
    <Name>DTX69.Jenkins.SCRANTN1</Name>
    <LastEdit Timestamp="2025-10-07T10:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="JENKINS" b2="69 KV" b3="SCRA1CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="SCRA1_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JENKINS" b2="69 KV" b3="SCRA1_S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JENKINS" b2="69 KV" b3="SCRANTN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101996</SeqNum>
    <Name>DTX69.LockHaven.RENOLD</Name>
    <LastEdit Timestamp="2025-10-07T10:25:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="LOCKHAVE" b2="69 KV" b3="FLEMCAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="LYC4RENO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="RENO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOCKHAVE" b2="69 KV" b3="RENOLD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101997</SeqNum>
    <Name>DTX69.LockHaven.FQLHLD</Name>
    <LastEdit Timestamp="2025-10-07T10:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="FQLH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOCKHAVE" b2="69 KV" b3="FQLHLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="LYC2FQLH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101998</SeqNum>
    <Name>DTX69.LockHaven.FLEMING</Name>
    <LastEdit Timestamp="2025-10-07T10:24:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="FLE" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LOCKHAVE" b2="69 KV" b3="FLEMCAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOCKHAVE" b2="69 KV" b3="FLEMING" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKHAVE" b2="69 KV" b3="LYC3FLEM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>101999</SeqNum>
    <Name>DTX230.MartinsCreek.LOAD1</Name>
    <LastEdit Timestamp="2025-10-07T10:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="2030SIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="AUX20-30" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARTINSC" b2="230 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102000</SeqNum>
    <Name>DTX69.Sunbury.TR20LD</Name>
    <LastEdit Timestamp="2025-10-07T10:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="TR20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="TR20TR26" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNBURY" b2="69 KV" b3="TR20_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102001</SeqNum>
    <Name>L69.Sunbury-Hamilton-Point.1</Name>
    <LastEdit Timestamp="2025-05-13T09:33:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HAMILTPL" b2="69 KV" b3="HAM-POI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAMILTPL" b2="69 KV" b3="HAM-SUN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAMILTPL" b2="69 KV" b3="HAMI1_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="HAMI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="HAMI1DAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102002</SeqNum>
    <Name>L69.Sunbury-Augustaville-Hunter</Name>
    <LastEdit Timestamp="2025-06-05T12:53:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AUGUSTVL" b2="69 KV" b3="AUG-HUNT" />
      <ContingencyEquipment Action="L" Type="LN" b1="AUGUSTVL" b2="69 KV" b3="AUG-SUNB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AUGUSTVL" b2="69 KV" b3="AUGU_LD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HUNTERPL" b2="69 KV" b3="2013" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HUNTERPL" b2="69 KV" b3="2015" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="ELDR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="ELDR12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102003</SeqNum>
    <Name>L69.SelingsGrv-HummelsW-Sunbury-Middlbrg-Bvrtwn.B</Name>
    <LastEdit Timestamp="2025-08-22T10:28:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BEAVRTWN" b2="69 KV" b3="4028" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAVRTWN" b2="69 KV" b3="BEAV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAVRTWN" b2="69 KV" b3="BEWE" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVRTWN" b2="69 KV" b3="BEA-MIDD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MIDDLBRG" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDDLBRG" b2="69 KV" b3="MID-SETP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIDDLBRG" b2="69 KV" b3="MIDD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SELINGRV" b2="69 KV" b3="4033" />
      <ContingencyEquipment Action="L" Type="LN" b1="SELINGRV" b2="69 KV" b3="SEL-SETP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="COLU2MID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="MIDD" />
      <ContingencyEquipment Action="L" Type="LN" b1="SETP" b2="69 KV" b3="SET-SUN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102004</SeqNum>
    <Name>DTX69.Sunbury.DAUPLD</Name>
    <LastEdit Timestamp="2025-05-13T09:36:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="DAUP_CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUNBURY" b2="69 KV" b3="DAUP_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="HAMI1DAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102006</SeqNum>
    <Name>DTX230.Susquehannat10.T10</Name>
    <LastEdit Timestamp="2025-10-07T10:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQT10" b2="230 KV" b3="MOUNT10T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQT10" b2="230 KV" b3="SUSQT10T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUSQT10" b2="230 KV" b3="T10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102032</SeqNum>
    <Name>Lutz.Yellowbud.SP</Name>
    <LastEdit Timestamp="2025-10-14T18:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LUTZ" b2="138 KV" b3="52T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUTZ" b2="138 KV" b3="52T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="LUTZ" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="LUTZ" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LUTZ" b2="34.5 KV" b3="YELWBDSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102037</SeqNum>
    <Name>L115.Claysmil-SedgeHill.1039</Name>
    <LastEdit Timestamp="2026-04-23T08:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSMIL" b2="115 KV" b3="103962" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSMIL" b2="115 KV" b3="33T1039" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="115 KV" b3="1039-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="115 KV" b3="1039-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLAYSMIL" b2="115 KV" b3="CLA-SEDG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102044</SeqNum>
    <Name>L345.908MoleCreek-939Mulberry.93913</Name>
    <LastEdit Timestamp="2025-10-15T14:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="908 MOLE" b2="345 KV" b3="BT1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="908 MOLE" b2="345 KV" b3="BT2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="908 MOLE" b2="345 KV" b3="MOL-MULB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="939_MUL" b2="345 KV" b3="7-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="939_MUL" b2="345 KV" b3="8-11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102057</SeqNum>
    <Name>DTX138.Sewickly.T1</Name>
    <LastEdit Timestamp="2022-09-19T15:33:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWICKLY" b2="138 KV" b3="1-2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWICKLY" b2="138 KV" b3="CRE-Z143" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SEWICKLY" b2="138 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102058</SeqNum>
    <Name>DTX138.Sewickly.T2</Name>
    <LastEdit Timestamp="2022-09-19T15:34:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWICKLY" b2="138 KV" b3="1-2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWICKLY" b2="138 KV" b3="BIZ-43" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SEWICKLY" b2="138 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102065</SeqNum>
    <Name>Callaway.U1 (ILLEQ)</Name>
    <LastEdit Timestamp="2025-10-15T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CALAWY 3" b2="25 KV" b3="L   G1UN" />
      <ContingencyEquipment Action="X" Type="XF" b1="CALAWY 3" b2="345 KV" b3="T 130225" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALAWY 3" b2="345 KV" b3="V53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALAWY 3" b2="345 KV" b3="V55" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102067</SeqNum>
    <Name>DTX138.HalfAcre.BK1</Name>
    <LastEdit Timestamp="2025-10-15T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HALFACRE" b2="138 KV" b3="883" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HALFACRE" b2="138 KV" b3="885" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HALFACRE" b2="138 KV" b3="BK1LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102068</SeqNum>
    <Name>L69.Koonsville-Glenbrook</Name>
    <LastEdit Timestamp="2025-10-16T13:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GLENBROO" b2="69 KV" b3="GLE-KOON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="69 KV" b3="HUNL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENBROO" b2="69 KV" b3="HUNLCOLU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KOONSVIL" b2="69 KV" b3="66380" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102069</SeqNum>
    <Name>L230.Aviator-PolandRd.2221 </Name>
    <LastEdit Timestamp="2024-09-10T13:31:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AVIATOR" b2="230 KV" b3="222152-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVIATOR" b2="230 KV" b3="222152-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POLANDRD" b2="230 KV" b3="222122" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVIATOR" b2="230 KV" b3="AVI-POLA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POLANDRD" b2="230 KV" b3="H3T2221" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102070</SeqNum>
    <Name>L230.Sojourner-Runway-Shellhorn.2218</Name>
    <LastEdit Timestamp="2025-12-18T16:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RUNWAYDP" b2="230 KV" b3="NOVEC" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUNWAYDP" b2="230 KV" b3="RUN-SHEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELHORN" b2="230 KV" b3="221842" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELHORN" b2="230 KV" b3="XT2218" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOJOURNR" b2="230 KV" b3="221862-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOJOURNR" b2="230 KV" b3="221862-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="RUNWAYDP" b2="230 KV" b3="RUN-SOJO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102071</SeqNum>
    <Name>DTX230.Sojourner.LD1 </Name>
    <LastEdit Timestamp="2026-05-11T11:43:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SOJOURNR" b2="230 KV" b3="221862-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOJOURNR" b2="230 KV" b3="229262-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOJOURNR" b2="230 KV" b3="232162-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOJOURNR" b2="230 KV" b3="LD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102072</SeqNum>
    <Name>DTX230.Sojourner.LD2 </Name>
    <LastEdit Timestamp="2026-05-11T11:43:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SOJOURNR" b2="230 KV" b3="221862-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOJOURNR" b2="230 KV" b3="229262-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOJOURNR" b2="230 KV" b3="232162-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOJOURNR" b2="230 KV" b3="LD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102073</SeqNum>
    <Name>L138.CollegeCorner-Centerville-Modoc</Name>
    <LastEdit Timestamp="2025-11-04T16:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CENTECIN" b2="69 KV" b3="138BK" />
      <ContingencyEquipment Action="X" Type="XF" b1="CENTECIN" b2="138 KV" b3="X1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTECIN" b2="138 KV" b3="CEN-CEN" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTERVI" b2="138 KV" b3="CEN-COL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CENTERVI" b2="138 KV" b3="CEN-MOD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLEGEC" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLEGEC" b2="138 KV" b3="J1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MODOC" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MODOC" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102075</SeqNum>
    <Name>138/69.Modoc.TR1 </Name>
    <LastEdit Timestamp="2025-11-10T11:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MODOC" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MODOC" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MODOC" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="X" Type="XF" b1="MODOC" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102076</SeqNum>
    <Name>L500.Cavalier-Septa.586 + CavalierSolar.SP</Name>
    <LastEdit Timestamp="2025-12-04T17:44:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAVALRSP" b2="500 KV" b3="52" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CAVALRSP" b2="34.5 KV" b3="CAVALRSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="CAVALRSP" b2="500 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEPTA4" b2="500 KV" b3="578T586" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEPTA4" b2="500 KV" b3="579T586" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAVALRSP" b2="500 KV" b3="CAV-SEPT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102077</SeqNum>
    <Name>L138.Cyprus-Parsons.2</Name>
    <LastEdit Timestamp="2024-12-13T08:44:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CYPRUS" b2="138 KV" b3="CYP-PAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000D5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARSONSA" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102079</SeqNum>
    <Name>L138.Cyprus-Parsons.1</Name>
    <LastEdit Timestamp="2025-12-01T11:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CYPRUS" b2="138 KV" b3="CYP-PAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000C5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARSONSA" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102080</SeqNum>
    <Name>DTX138.Cyprus.GentoB</Name>
    <LastEdit Timestamp="2024-05-14T10:11:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CYPRUS" b2="138 KV" b3="GENTOB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000D5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000D8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102081</SeqNum>
    <Name>DTX138.Cyprus.GentoA</Name>
    <LastEdit Timestamp="2024-05-14T10:11:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CYPRUS" b2="138 KV" b3="GENTOA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000F5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000F8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102085</SeqNum>
    <Name>L138.NWoodcock-NorthFindlay</Name>
    <LastEdit Timestamp="2025-10-17T12:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="NFINDLAY" b2="138 KV" b3="NFI-NWO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NFINDLAY" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWOODCOC" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102086</SeqNum>
    <Name>138/69/34.NWoodcock.T1</Name>
    <LastEdit Timestamp="2025-10-16T13:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NWOODCOC" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="NWOODCOC" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="NWOODCOC" b2="34 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWOODCOC" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWOODCOC" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NWOODCOC" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NWOODCOC" b2="34 KV" b3="MORRICAL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102087</SeqNum>
    <Name>138/69.Strawton.T1</Name>
    <LastEdit Timestamp="2025-11-10T14:00:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STRAWTON" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="X" Type="XF" b1="STRAWTON" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRAWTON" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102092</SeqNum>
    <Name>L138.Sheridan-Elynn-Lavalett-Shoals</Name>
    <LastEdit Timestamp="2025-10-16T14:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELYNN" b2="138 KV" b3="ELY-LAV1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELYNN" b2="138 KV" b3="T1T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAVALETT" b2="138 KV" b3="LAV-SHO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAVALETT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELYNN" b2="138 KV" b3="ELY-SHER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERIDAN" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHOALS" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102094</SeqNum>
    <Name>L115.SedgeHill-Huber-WoodchuckTrail.1047</Name>
    <LastEdit Timestamp="2025-11-25T16:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUBER" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="115 KV" b3="1041702" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="115 KV" b3="151T1047" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUBER" b2="115 KV" b3="HUB-SEDG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WDCHKTRL" b2="115 KV" b3="10161047" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WDCHKTRL" b2="115 KV" b3="104772" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUBER" b2="115 KV" b3="HUB-WDCH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102095</SeqNum>
    <Name>L138.Dublin-Amlin</Name>
    <LastEdit Timestamp="2025-10-17T12:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMLIN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMLIN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMLIN" b2="138 KV" b3="AML-DUBL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUBLIN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUBLIN" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102096</SeqNum>
    <Name>L230.Burlington-Bustleton-Mansfield.2355</Name>
    <LastEdit Timestamp="2025-10-17T12:16:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="1-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURLINGT" b2="230 KV" b3="2-12" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURLINGT" b2="230 KV" b3="BUR-BUSX" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUSTLETO" b2="230 KV" b3="BUS-MANS" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BUSTLETO" b2="13 KV" b3="BUSTSP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BUSTLETO" b2="13 KV" b3="GHLF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUSTLETO" b2="230 KV" b3="T-1CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUSTLETO" b2="13 KV" b3="T1LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUSTLETO" b2="230 KV" b3="TXR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFLD" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANSFLD" b2="230 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102097</SeqNum>
    <Name>L69.Millsboro-Zoar.6734</Name>
    <LastEdit Timestamp="2025-11-11T10:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILSBORO" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILSBORO" b2="69 KV" b3="7440" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILSBORO" b2="69 KV" b3="MIL-ZOAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZOAR" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZOAR" b2="69 KV" b3="64" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102099</SeqNum>
    <Name>L138.Lakin-Sporn</Name>
    <LastEdit Timestamp="2025-10-17T12:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKIN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKIN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAKIN" b2="138 KV" b3="LAK-SPO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="N2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102100</SeqNum>
    <Name>DTX138.Lakin.T4</Name>
    <LastEdit Timestamp="2025-10-17T12:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKIN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKIN" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAKIN" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102101</SeqNum>
    <Name>942NelsonEC.GT3CT</Name>
    <LastEdit Timestamp="2025-10-28T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="942 NELS" b2="345 KV" b3="5243" />
      <ContingencyEquipment Action="OP" Type="CB" b1="942 NELS" b2="18 KV" b3="52CSGT3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="942 NELS" b2="18 KV" b3="GT3CT_1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="942 NELS" b2="18 KV" b3="SS3" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="345 KV" b3="TR3GSU-P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102102</SeqNum>
    <Name>942NelsonEC.GT4CT</Name>
    <LastEdit Timestamp="2025-10-28T11:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="942 NELS" b2="345 KV" b3="5244" />
      <ContingencyEquipment Action="U" Type="GEN" b1="942 NELS" b2="18 KV" b3="GT4CT_1" />
      <ContingencyEquipment Action="X" Type="XF" b1="942 NELS" b2="345 KV" b3="TR4GSU-P" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102103</SeqNum>
    <Name>DTX138.Beatty.T1&amp;2</Name>
    <LastEdit Timestamp="2025-10-17T12:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="L2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEATTY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEATTY" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102104</SeqNum>
    <Name>L161.JoppaNorth-Grahamville.1</Name>
    <LastEdit Timestamp="2025-10-28T12:10:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAHAMVI" b2="161 KV" b3="B161_854" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GRAHAMVI" b2="161 KV" b3="B161_857" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOPPA" b2="161 KV" b3="1664" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOPPA" b2="161 KV" b3="1668" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRAHAMVI" b2="161 KV" b3="GRA-JOP1" />
      <ContingencyEquipment Action="S" Type="SD" b1="JOPPA" b2="161 KV" b3="G_TAP" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOPPA" b2="161 KV" b3="JOP-JOPG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOPPA_S" b2="161 KV" b3="1602" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102106</SeqNum>
    <Name>DTX138.Italian.XFM1</Name>
    <LastEdit Timestamp="2025-10-20T10:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ITALIANV" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ITALIANV" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ITALIANV" b2="138 KV" b3="XFM1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102107</SeqNum>
    <Name>DTX138.Italian.XFM2</Name>
    <LastEdit Timestamp="2025-10-20T10:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ITALIANV" b2="138 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ITALIANV" b2="138 KV" b3="9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ITALIANV" b2="138 KV" b3="XFM2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102108</SeqNum>
    <Name>DTX138.Turner.T4</Name>
    <LastEdit Timestamp="2025-10-20T10:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURNER" b2="138 KV" b3="F1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TURNER" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102109</SeqNum>
    <Name>DTX138.Ross.TR2</Name>
    <LastEdit Timestamp="2025-10-20T10:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSS" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROSS" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102110</SeqNum>
    <Name>DTX138.Torrey.T1&amp;4</Name>
    <LastEdit Timestamp="2026-05-08T15:13:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TORREY" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="TORREY" b2="138 KV" b3="CAPAF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TORREY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TORREY" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TORREY" b2="138 KV" b3="Y" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102111</SeqNum>
    <Name>L345.Kansas-Arlond</Name>
    <LastEdit Timestamp="2025-10-20T10:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARLD" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARLD" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARLD" b2="345 KV" b3="ARL-KANS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANSAS 3" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANSAS 3" b2="345 KV" b3="V15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102125</SeqNum>
    <Name>138/69.Haviland.T4 (Sctnlz) </Name>
    <LastEdit Timestamp="2026-02-23T12:42:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAVILAND" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAVILAND" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAVILAND" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAVILAND" b2="69 KV" b3="T" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAVILAND" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102126</SeqNum>
    <Name>138/69.Inez.TR2</Name>
    <LastEdit Timestamp="2025-11-25T16:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INEZ" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INEZ" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INEZ" b2="69 KV" b3="M" />
      <ContingencyEquipment Action="X" Type="XF" b1="INEZ" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102127</SeqNum>
    <Name>L138.CedarCreek-Raccoon-JohnsCreek &amp; LoadSwap</Name>
    <LastEdit Timestamp="2025-08-21T17:11:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCR2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="CEDARCR2" b2="46 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSCRE" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOHNSCRE" b2="138 KV" b3="JON-RACC" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARCR2" b2="138 KV" b3="CED-RACC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102129</SeqNum>
    <Name>L230.Roundtable-Lockridge.2223</Name>
    <LastEdit Timestamp="2026-03-30T18:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKRDGE" b2="230 KV" b3="222372" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKRDGE" b2="230 KV" b3="H12T2223" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOCKRDGE" b2="230 KV" b3="LOC-ROUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTBL" b2="230 KV" b3="20312223" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTBL" b2="230 KV" b3="222302" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102130</SeqNum>
    <Name>L138.WKingsport-How</Name>
    <LastEdit Timestamp="2026-02-10T09:52:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HOW" b2="138 KV" b3="HOW-WKI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOW" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WKINGSPO" b2="138 KV" b3="CAPB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WKINGSPO" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WKINGSPO" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WKINGSPO" b2="138 KV" b3="X1 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WKINGSPO" b2="138 KV" b3="XT3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WKINGSPO" b2="138 KV" b3="Y" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102131</SeqNum>
    <Name>L345.Labadie-WLWD-Mason3</Name>
    <LastEdit Timestamp="2025-08-22T08:23:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LABADIE3" b2="345 KV" b3="LAB-WLWD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LABADIE3" b2="345 KV" b3="MASN L 3" />
      <ContingencyEquipment Action="L" Type="LN" b1="MASON 13" b2="345 KV" b3="MAS-WLWD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASON 13" b2="345 KV" b3="Q" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLWD" b2="138 KV" b3="XFMR 1L" />
      <ContingencyEquipment Action="X" Type="XF" b1="WLWD" b2="345 KV" b3="XFMR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102132</SeqNum>
    <Name>L138.Edwards-Fargo</Name>
    <LastEdit Timestamp="2025-12-16T11:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDWARDS3" b2="138 KV" b3="H7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDWARDS3" b2="138 KV" b3="H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARGO  3" b2="138 KV" b3="H43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARGO  3" b2="138 KV" b3="H45" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDWARDS3" b2="138 KV" b3="LN  3007" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102137</SeqNum>
    <Name>L69.Rowan-Glassboro.0729 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-21T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GLASSBOR" b2="69 KV" b3="ABS-K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROWAN" b2="69 KV" b3="GCB C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROWAN" b2="69 KV" b3="GCB D" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLASSBOR" b2="69 KV" b3="GLA-ROW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102138</SeqNum>
    <Name>L69.Monsanto-Nortonville.0705 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-21T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MONSANTO" b2="69 KV" b3="MON-NORT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONSANTO" b2="69 KV" b3="OCB B" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="NORTONVL" b2="69 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102139</SeqNum>
    <Name>L69.Oldman-Nortonville.0705 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-21T13:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="NORTONVL" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORTONVL" b2="69 KV" b3="NOR-OLDM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLDMAN" b2="69 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102140</SeqNum>
    <Name>L69.Terrace-Pitman.0756-2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-21T13:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PITMAN" b2="69 KV" b3="OCB D" />
      <ContingencyEquipment Action="L" Type="LN" b1="PITMAN" b2="69 KV" b3="PIT-TER" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERRACE" b2="69 KV" b3="ABS B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102141</SeqNum>
    <Name>L138.Keeney-ChurchmansTap.13806 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-20T10:47:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHURCTAP" b2="138 KV" b3="13806-L1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHURCTAP" b2="138 KV" b3="CHU-KEE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEENEY" b2="138 KV" b3="134" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102142</SeqNum>
    <Name>L138.BasinRoad-ChurchmansTap.13807 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-10-20T10:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BASINRD" b2="138 KV" b3="136" />
      <ContingencyEquipment Action="L" Type="LN" b1="BASINRD" b2="138 KV" b3="BAS-CHU" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHURCTAP" b2="138 KV" b3="13807-L3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102148</SeqNum>
    <Name>L138.Corbin-Rutland (IP/MISO)</Name>
    <LastEdit Timestamp="2025-10-30T11:02:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRBN" b2="138 KV" b3="CRB-RTLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRBN" b2="138 KV" b3="H53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRBN" b2="138 KV" b3="H55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RTLD" b2="138 KV" b3="H5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RTLD" b2="138 KV" b3="H7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102150</SeqNum>
    <Name>Columbia.T3.138/69kv.XFMR</Name>
    <LastEdit Timestamp="2025-10-21T13:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLUMBIA" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLUMBIA" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLUMBIA" b2="69 KV" b3="K1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLUMBIA" b2="69 KV" b3="L1" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLUMBIA" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102151</SeqNum>
    <Name>Columbia.T4.138/69kv.XFMR</Name>
    <LastEdit Timestamp="2025-10-21T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLUMBIA" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLUMBIA" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLUMBIA" b2="69 KV" b3="K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLUMBIA" b2="69 KV" b3="L2" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLUMBIA" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102152</SeqNum>
    <Name>Lakin.T3.138/69kv.XFMR</Name>
    <LastEdit Timestamp="2025-10-21T13:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LAKIN" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKIN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKIN" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAKIN" b2="69 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102156</SeqNum>
    <Name>L138.Bixby-Pickerington-Sifford</Name>
    <LastEdit Timestamp="2025-11-04T16:43:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="138 KV" b3="110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="138 KV" b3="112" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIXBY" b2="138 KV" b3="BIX-PIC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PICKERI2" b2="138 KV" b3="PIC-SIFF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PICKERI2" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIFFORD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIFFORD" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102158</SeqNum>
    <Name>L138.Sifford-WLancast</Name>
    <LastEdit Timestamp="2025-10-29T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SIFFORD" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIFFORD" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WLANCAST" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="SIFFORD" b2="138 KV" b3="SIF-WLAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102159</SeqNum>
    <Name>L69.Angora-Civic</Name>
    <LastEdit Timestamp="2025-10-29T10:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGORA" b2="69 KV" b3="210 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGORA" b2="69 KV" b3="2TRHS CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGORA" b2="13 KV" b3="2TRLS CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="ANGORA" b2="69 KV" b3="ANG 2TR" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANGORA" b2="69 KV" b3="ANG-CIVI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CIVIC" b2="69 KV" b3="315 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CIVIC" b2="69 KV" b3="325 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102163</SeqNum>
    <Name>L138.NewBourbon-SMNY(ILL EQ)</Name>
    <LastEdit Timestamp="2025-10-29T10:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PERRYVI3" b2="138 KV" b3="31305314" />
      <ContingencyEquipment Action="OP" Type="CB" b1="N BURBN3" b2="138 KV" b3="B101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERRYVI3" b2="138 KV" b3="B105" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102164</SeqNum>
    <Name>L230.Moyock-PuddingRidge.2235</Name>
    <LastEdit Timestamp="2024-11-20T13:58:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOYOCK" b2="230 KV" b3="21922235" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOYOCK" b2="230 KV" b3="223502" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOYOCK" b2="230 KV" b3="MOY-PUDD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUDDNRID" b2="230 KV" b3="20872235" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUDDNRID" b2="230 KV" b3="223582" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102165</SeqNum>
    <Name>BeechBranch.SP.BCHBRNSP</Name>
    <LastEdit Timestamp="2025-03-26T16:33:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BCHBRNCH" b2="115 KV" b3="104832" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BCHBRNCH" b2="115 KV" b3="8032" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BCHBRNCH" b2="34.5 KV" b3="BCHBRNSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="BCHBRNCH" b2="115 KV" b3="GSU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BCHBRNCH" b2="34.5 KV" b3="GSU_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102166</SeqNum>
    <Name>Claysmill.SUNNYBSP</Name>
    <LastEdit Timestamp="2025-10-30T15:17:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLAYSMIL" b2="34.5 KV" b3="SUNNYBSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLAYSMIL" b2="115 KV" b3="SUNNYGSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAYSMIL" b2="115 KV" b3="W64" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102167</SeqNum>
    <Name>L138.Shankatank-TannersCreek</Name>
    <LastEdit Timestamp="2025-10-29T10:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHANKATK" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHANKATK" b2="138 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHANKATK" b2="138 KV" b3="SHA-TANN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102169</SeqNum>
    <Name>230/115.Hickory.TX4</Name>
    <LastEdit Timestamp="2025-10-30T15:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORY" b2="115 KV" b3="1632" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORY" b2="115 KV" b3="H232" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORY" b2="230 KV" b3="H432" />
      <ContingencyEquipment Action="X" Type="XF" b1="HICKORY" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102170</SeqNum>
    <Name>L345.AltaFarm-DeerCreek.197201 + Altafarm.WF</Name>
    <LastEdit Timestamp="2025-10-30T15:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="909DCREE" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="909DCREE" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALTAFARM" b2="345 KV" b3="ALT-DCRE" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ALTAFARM" b2="34.5 KV" b3="AFARMWF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAFARM" b2="345 KV" b3="T1CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102171</SeqNum>
    <Name>L345.Brokaw-DeerCreek.190907</Name>
    <LastEdit Timestamp="2025-11-14T09:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="909DCREE" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="909DCREE" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROKAW" b2="345 KV" b3="BRO-DCRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="345 KV" b3="4539" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROKAW" b2="345 KV" b3="4543" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102175</SeqNum>
    <Name>L69.Sunbury-Point.2</Name>
    <LastEdit Timestamp="2025-05-13T09:38:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="POINT1" b2="69 KV" b3="POI-SUN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="COLU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="COLU2MID" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102288</SeqNum>
    <Name>L138.593WillowSp-59306-Burridge-J310ArgonneLab</Name>
    <LastEdit Timestamp="2026-05-08T14:25:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="136 BURR" b2="138 KV" b3="59306_3" />
      <ContingencyEquipment Action="CL" Type="CB" b1="136 BURR" b2="138 KV" b3="BT2-3CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="136 BURR" b2="138 KV" b3="L59306" />
      <ContingencyEquipment Action="L" Type="LN" b1="59306" b2="138 KV" b3="59306__1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="593 WILL" b2="138 KV" b3="L59306CS" />
      <ContingencyEquipment Action="L" Type="LN" b1="J310" b2="138 KV" b3="59306_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="J310" b2="138 KV" b3="6-7CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="J310" b2="138 KV" b3="7-8CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102290</SeqNum>
    <Name>L138.MierPSI-Wabash (CIN/MISO)</Name>
    <LastEdit Timestamp="2026-05-08T11:32:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="MIERPSI" b2="138 KV" b3="LABW_DS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WABASPSI" b2="138 KV" b3="13848" />
      <ContingencyEquipment Action="L" Type="LN" b1="WABASPSI" b2="138 KV" b3="WAB-MIE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102291</SeqNum>
    <Name>L69.Columbia-University-Scott.2</Name>
    <LastEdit Timestamp="2025-02-19T08:37:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLU PL" b2="69 KV" b3="COL-UNI2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="69 KV" b3="GLBR2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCOTTPL" b2="69 KV" b3="SCOT2 LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCOTTPL" b2="69 KV" b3="SCO-UNI2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIVERPL" b2="69 KV" b3="UNIV_LD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102292</SeqNum>
    <Name>L138.WestMoulton-CityofStMarys</Name>
    <LastEdit Timestamp="2025-10-30T15:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CITYSTMA" b2="138 KV" b3="AC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CITYSTMA" b2="138 KV" b3="GENCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CITYSTMA" b2="138 KV" b3="T11" />
      <ContingencyEquipment Action="L" Type="LN" b1="WMOULTON" b2="138 KV" b3="WMO-CIT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMOULTON" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMOULTON" b2="138 KV" b3="K" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102295</SeqNum>
    <Name>L345.Tanner-Xena.4526</Name>
    <LastEdit Timestamp="2025-11-03T14:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TANN" b2="345 KV" b3="V5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANN" b2="345 KV" b3="V7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="XENA" b2="345 KV" b3="3577" />
      <ContingencyEquipment Action="OP" Type="CB" b1="XENA" b2="345 KV" b3="3578" />
      <ContingencyEquipment Action="L" Type="LN" b1="TANN" b2="345 KV" b3="TAN-XENA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102296</SeqNum>
    <Name>L138.Marion-Mound</Name>
    <LastEdit Timestamp="2025-10-30T15:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUND" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOUND" b2="138 KV" b3="104" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARION2" b2="138 KV" b3="MAR-MOUN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102297</SeqNum>
    <Name>L138.Danville-Brosville</Name>
    <LastEdit Timestamp="2026-05-01T09:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROSVILL" b2="138 KV" b3="A000Y8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DANVILLE" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROSVILL" b2="138 KV" b3="BRO-DANV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102302</SeqNum>
    <Name>230/115.Hooversville.3TX</Name>
    <LastEdit Timestamp="2025-12-23T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HOOVERSV" b2="230 KV" b3="3 TX  1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOOVERSV" b2="115 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOOVERSV" b2="230 KV" b3="B53" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102304</SeqNum>
    <Name>L138.Charger-Ligonier</Name>
    <LastEdit Timestamp="2025-11-03T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARGER" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARGER" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHARGER" b2="138 KV" b3="CHA-LIG" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LIGONIER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LIGONIER" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102309</SeqNum>
    <Name>L115.ElmStreetTap-Warren (Sctnlz)</Name>
    <LastEdit Timestamp="2025-11-03T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELMSTTAP" b2="115 KV" b3="WARREN D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="115 KV" b3="B92" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARREN" b2="115 KV" b3="B93" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELMSTTAP" b2="115 KV" b3="ELM-WAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102312</SeqNum>
    <Name>L138.ChatField-RedRun</Name>
    <LastEdit Timestamp="2025-06-12T12:47:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHATFIEL" b2="138 KV" b3="CHA-REDR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHATFIEL" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHATFIEL" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDRUNAE" b2="138 KV" b3="H005X5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDRUNAE" b2="138 KV" b3="H005X8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102314</SeqNum>
    <Name>L345.Arcadian-Paris.W30 (WEC)</Name>
    <LastEdit Timestamp="2024-09-05T15:00:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARCADIAN" b2="345 KV" b3="9273" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARCADIAN" b2="345 KV" b3="9274" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARIS 83" b2="345 KV" b3="9303" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARIS 83" b2="345 KV" b3="9304" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARCADIAN" b2="345 KV" b3="ARC-PARI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102315</SeqNum>
    <Name>L138.RobisonPark-Hacienda-Harper-Milan</Name>
    <LastEdit Timestamp="2024-12-18T16:50:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HACIENDA" b2="138 KV" b3="HAC-HAR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HACIENDA" b2="138 KV" b3="HAC-ROB1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HACIENDA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARPER" b2="138 KV" b3="HAR-MIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARPER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILANSS" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILANSS" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="D2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102319</SeqNum>
    <Name>138/69.Hazard.T1</Name>
    <LastEdit Timestamp="2025-11-04T09:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HAZARD" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZARD" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAZARD" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102322</SeqNum>
    <Name>L345.LakeRedmonRoad-HardinC</Name>
    <LastEdit Timestamp="2025-11-06T14:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="345 KV" b3="CB944" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="345 KV" b3="CB954" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LKREDMNR" b2="345 KV" b3="904" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LKREDMNR" b2="345 KV" b3="924" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDIN_C" b2="345 KV" b3="HAR-LKRE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102323</SeqNum>
    <Name>L345.LakeRedmonRoad-OtterCreek</Name>
    <LastEdit Timestamp="2025-12-20T17:41:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LKREDMNR" b2="345 KV" b3="914" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LKREDMNR" b2="345 KV" b3="924" />
      <ContingencyEquipment Action="L" Type="LN" b1="LKREDMNR" b2="345 KV" b3="LKR-OTTE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTERCRK" b2="345 KV" b3="546" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTERCRK" b2="345 KV" b3="552" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102324</SeqNum>
    <Name>L69.Highland-Martinsville-EastFork</Name>
    <LastEdit Timestamp="2025-09-12T15:45:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTFORK" b2="69 KV" b3="HS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTFORK" b2="69 KV" b3="HS3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLND2" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLND2" b2="69 KV" b3="HIG-09M1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARTIDPL" b2="69 KV" b3="BK-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARTIDPL" b2="69 KV" b3="BK-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EASTFORK" b2="69 KV" b3="EAS-MART" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARTIDPL" b2="69 KV" b3="NEWVIENN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102329</SeqNum>
    <Name>138/69.ChatField.TR2</Name>
    <LastEdit Timestamp="2025-11-07T14:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHATFIEL" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHATFIEL" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHATFIEL" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHATFIEL" b2="69 KV" b3="J" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHATFIEL" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102330</SeqNum>
    <Name>L138.WestMilton-Eldean</Name>
    <LastEdit Timestamp="2025-11-07T15:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ELDEAN1" b2="138 KV" b3="ELD-WMIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDEAN1" b2="138 KV" b3="OR-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDEAN1" b2="138 KV" b3="OR-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="138 KV" b3="OC-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="138 KV" b3="OC-C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102331</SeqNum>
    <Name>L138.Midway-Wauseon</Name>
    <LastEdit Timestamp="2025-11-07T15:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13305" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIDWAYTE" b2="138 KV" b3="MID-WAUS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAUSEON" b2="138 KV" b3="B51" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102332</SeqNum>
    <Name>L138.Melmore-ChatField</Name>
    <LastEdit Timestamp="2025-11-07T15:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHATFIEL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHATFIEL" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELMORE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MELMORE" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHATFIEL" b2="138 KV" b3="CHA-MEL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102340</SeqNum>
    <Name>L230.Idylwood-Tysons.2175</Name>
    <LastEdit Timestamp="2026-01-07T09:14:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IDYLWOO4" b2="230 KV" b3="2022175X" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYSONS" b2="230 KV" b3="217532" />
      <ContingencyEquipment Action="L" Type="LN" b1="IDYLWOO4" b2="230 KV" b3="IDY-TYS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYSONS" b2="230 KV" b3="WT2175" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102341</SeqNum>
    <Name>DTX.Waterfront.T4</Name>
    <LastEdit Timestamp="2025-11-07T14:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="4ACB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="4BCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102342</SeqNum>
    <Name>DTX.Waterfront.T6</Name>
    <LastEdit Timestamp="2025-11-07T14:54:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="6ACB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="6BCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102344</SeqNum>
    <Name>L115.LaCrosse-Brodnax.1064</Name>
    <LastEdit Timestamp="2026-03-30T18:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRODNAX" b2="115 KV" b3="71T1064" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRODNAX" b2="115 KV" b3="BRO-LACR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACROSSE" b2="115 KV" b3="106422" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LACROSSE" b2="115 KV" b3="H1T1064" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102345</SeqNum>
    <Name>L230.SusquehannaU1-Susquehanna230kV.YARDSPAN</Name>
    <LastEdit Timestamp="2026-04-20T12:51:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SUSQUEHA" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="GEN1-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="GEN1-W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="SYNCHRO" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SUSQUEHA" b2="24 KV" b3="UNIT01" />
      <ContingencyEquipment Action="S" Type="SD" b1="SUSQUEHA" b2="230 KV" b3="YARDSPAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102346</SeqNum>
    <Name>230/69.Susquehanna.T1</Name>
    <LastEdit Timestamp="2025-11-07T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SUSQUEHA" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="T1HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="69 KV" b3="T1LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102350</SeqNum>
    <Name>L230.BearRock-FiddlersGreen</Name>
    <LastEdit Timestamp="2025-10-27T18:36:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARROCK" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEARROCK" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEARROCK" b2="230 KV" b3="BEA-FID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIDDLERS" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIDDLERS" b2="230 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102351</SeqNum>
    <Name>L230.Johnstown-FiddlersGreen</Name>
    <LastEdit Timestamp="2025-10-27T18:36:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FIDDLERS" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIDDLERS" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOHNSTOW" b2="230 KV" b3="B7" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIDDLERS" b2="230 KV" b3="FID-JOH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102358</SeqNum>
    <Name>230/34.FiddlersGreen.T1</Name>
    <LastEdit Timestamp="2025-11-07T14:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FIDDLERS" b2="34.5 KV" b3="B24" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FIDDLERS" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIDDLERS" b2="34.5 KV" b3="FIDDLECB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FIDDLERS" b2="34.5 KV" b3="FIDDLESP" />
      <ContingencyEquipment Action="X" Type="XF" b1="FIDDLERS" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIDDLERS" b2="230 KV" b3="T1_B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102360</SeqNum>
    <Name>L230.SedgeHill-Alton.296</Name>
    <LastEdit Timestamp="2024-06-10T19:17:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTON" b2="230 KV" b3="29652" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTON" b2="230 KV" b3="296T2217" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALTON" b2="230 KV" b3="ALT-SEDG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="230 KV" b3="H1T296" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="230 KV" b3="H2T296" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102361</SeqNum>
    <Name>L230.Hendrick-Person(CPL).2241</Name>
    <LastEdit Timestamp="2024-08-20T07:45:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HENDRICK" b2="230 KV" b3="22172241" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HENDRICK" b2="230 KV" b3="224162" />
      <ContingencyEquipment Action="L" Type="LN" b1="HENDRICK" b2="230 KV" b3="HEN-PERS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERSON4" b2="230 KV" b3="6HND_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERSON4" b2="230 KV" b3="ROXB_6HN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102362</SeqNum>
    <Name>L230.NewFreedom-Hilltop.K2237</Name>
    <LastEdit Timestamp="2025-11-10T11:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTPPS" b2="230 KV" b3="1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTPPS" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLTPPS" b2="230 KV" b3="HIL-NEWF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="230 2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWFREED" b2="230 KV" b3="230 7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102363</SeqNum>
    <Name>L230.BeaverBrook-Hilltop.G2338</Name>
    <LastEdit Timestamp="2025-11-10T14:23:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="BEAVERBR" b2="230 KV" b3="BEAVBRSP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BEAVERBR" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVERBR" b2="230 KV" b3="SECT 1-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEAVERBR" b2="230 KV" b3="T-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTPPS" b2="230 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTPPS" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVERBR" b2="230 KV" b3="BEA-HILL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102364</SeqNum>
    <Name>L138.WestMilton-Airport</Name>
    <LastEdit Timestamp="2025-11-10T11:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AIRPORT2" b2="138 KV" b3="AIR-WMIL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AIRPORT2" b2="138 KV" b3="RO-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AIRPORT2" b2="138 KV" b3="RO-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="138 KV" b3="OC-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMILTON" b2="138 KV" b3="OC-D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102365</SeqNum>
    <Name>L138.Airport-Miami</Name>
    <LastEdit Timestamp="2025-11-10T11:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AIRPORT2" b2="138 KV" b3="RO-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AIRPORT2" b2="138 KV" b3="RO-E" />
      <ContingencyEquipment Action="L" Type="LN" b1="AIRPORT2" b2="138 KV" b3="AIR-MIAM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMI" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102366</SeqNum>
    <Name>DTX.Airpot.BK-2</Name>
    <LastEdit Timestamp="2025-11-07T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AIRPORT2" b2="138 KV" b3="BK-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AIRPORT2" b2="138 KV" b3="RO-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AIRPORT2" b2="138 KV" b3="RO-E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102367</SeqNum>
    <Name>DTX138.Airport.SALYRSUB</Name>
    <LastEdit Timestamp="2025-03-07T09:40:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AIRPORT2" b2="138 KV" b3="RO-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AIRPORT2" b2="138 KV" b3="RO-C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AIRPORT2" b2="138 KV" b3="SALYRSUB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102371</SeqNum>
    <Name>L138.Babbitt-Hazelton-Kirk</Name>
    <LastEdit Timestamp="2025-07-09T10:16:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BABBITT" b2="138 KV" b3="BAB-HAZL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="N1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HAZLTNAP" b2="138 KV" b3="BEECHWD" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAZLTNAP" b2="138 KV" b3="HAZ-KIR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="138 KV" b3="101C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KIRK" b2="138 KV" b3="101N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102372</SeqNum>
    <Name>L138.CollegeCorner-Collinsville</Name>
    <LastEdit Timestamp="2025-11-10T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COLLEGEC" b2="138 KV" b3="COL-COL6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLEGEC" b2="138 KV" b3="M2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLINSV" b2="138 KV" b3="957" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLINSV" b2="138 KV" b3="959" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102373</SeqNum>
    <Name>L138.Collinsville-Huston-Trenton</Name>
    <LastEdit Timestamp="2025-11-10T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLINSV" b2="138 KV" b3="953" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLINSV" b2="138 KV" b3="959" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUSTON" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLLINSV" b2="138 KV" b3="HUS-COL" />
      <ContingencyEquipment Action="L" Type="LN" b1="TRENTON2" b2="138 KV" b3="HUS-TRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRENTON2" b2="138 KV" b3="808" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102374</SeqNum>
    <Name>138/69.Collinsville.BK2</Name>
    <LastEdit Timestamp="2025-11-07T14:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLINSV" b2="69 KV" b3="671" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLINSV" b2="69 KV" b3="676" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLINSV" b2="138 KV" b3="953" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLINSV" b2="138 KV" b3="957" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLLINSV" b2="138 KV" b3="BK2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102375</SeqNum>
    <Name>DTX69.HighStreet.T2</Name>
    <LastEdit Timestamp="2025-11-10T14:02:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHST" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHST" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIGHST" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102376</SeqNum>
    <Name>L138.DeerCreek-Beatty</Name>
    <LastEdit Timestamp="2025-11-10T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="5C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="138 KV" b3="5W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCR" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCR" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEATTY" b2="138 KV" b3="BEA-DEA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102377</SeqNum>
    <Name>L138.DeerCreek-London</Name>
    <LastEdit Timestamp="2025-11-10T11:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCR" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCR" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEERCR" b2="138 KV" b3="DEA-LON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONDONOE" b2="138 KV" b3="B199" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102378</SeqNum>
    <Name>Wildcat.WILLOWSP</Name>
    <LastEdit Timestamp="2025-11-10T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WILDCAT" b2="138 KV" b3="GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="WILDCAT" b2="138 KV" b3="MPT-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WILDCAT" b2="34.5 KV" b3="WILLOWSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102379</SeqNum>
    <Name>L230.Hourglass-Pioneer.2196</Name>
    <LastEdit Timestamp="2026-01-13T11:29:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOURGLAS" b2="230 KV" b3="219662-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOURGLAS" b2="230 KV" b3="219662-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIONEER1" b2="230 KV" b3="21962314" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIONEER1" b2="230 KV" b3="219692" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOURGLAS" b2="230 KV" b3="HOU-PION" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102381</SeqNum>
    <Name>230/69.Hilltop.220-1</Name>
    <LastEdit Timestamp="2025-11-07T14:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTPPS" b2="69 KV" b3="2-3" />
      <ContingencyEquipment Action="X" Type="XF" b1="HILLTPPS" b2="230 KV" b3="220-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTPPS" b2="230 KV" b3="220-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLTPPS" b2="69 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102383</SeqNum>
    <Name>345/138.BentonHarbor.T2</Name>
    <LastEdit Timestamp="2025-11-13T13:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BENTONHA" b2="345 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="345 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONHA" b2="138 KV" b3="F1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102387</SeqNum>
    <Name>L69.Churchtown-Beckett.0722</Name>
    <LastEdit Timestamp="2025-11-21T12:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BECKETT" b2="69 KV" b3="BEC-CHU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKETT" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="ES" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCHTO" b2="69 KV" b3="GQ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102389</SeqNum>
    <Name>DTX230.Easters.LD3</Name>
    <LastEdit Timestamp="2024-06-10T19:18:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTERS" b2="230 KV" b3="LD3_Y37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="T342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="Y32" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102390</SeqNum>
    <Name>DTX230.Easters.LD4</Name>
    <LastEdit Timestamp="2024-06-10T19:19:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTERS" b2="230 KV" b3="LD4_U37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="T342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="U32" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102391</SeqNum>
    <Name>DTX230.Easters.LD5</Name>
    <LastEdit Timestamp="2024-06-10T19:19:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EASTERS" b2="230 KV" b3="LD5_Z37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="T562" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="Z32" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102400</SeqNum>
    <Name>L138.Fuson-Cowan</Name>
    <LastEdit Timestamp="2025-11-13T13:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COWANIM" b2="138 KV" b3="M001J2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COWANIM" b2="138 KV" b3="M001K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FUSON" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="COWANIM" b2="138 KV" b3="COW-FUSO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FUSON" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FUSON" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102401</SeqNum>
    <Name>L138.Cowan-Westinghouse-23rdSt</Name>
    <LastEdit Timestamp="2025-11-13T13:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="23RDSTRE" b2="138 KV" b3="23R-WES2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="23RDSTRE" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="23RDSTRE" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="COWANIM" b2="138 KV" b3="COW-WEST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COWANIM" b2="138 KV" b3="M001J5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COWANIM" b2="138 KV" b3="M001J8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTNGIM" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTNGIM" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTNGIM" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTNGIM" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102405</SeqNum>
    <Name>138/69.Beckjord.BK10</Name>
    <LastEdit Timestamp="2025-11-21T12:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="69 KV" b3="634" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="69 KV" b3="636" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKJORD" b2="138 KV" b3="824" />
      <ContingencyEquipment Action="X" Type="XF" b1="BECKJORD" b2="138 KV" b3="BK10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102413</SeqNum>
    <Name>L138.K323-19907-Kensington-Kankakee.19907</Name>
    <LastEdit Timestamp="2025-11-30T18:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="157 KANK" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="157 KANK" b2="138 KV" b3="L19907CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="199 KENS" b2="138 KV" b3="L19907" />
      <ContingencyEquipment Action="L" Type="LN" b1="19907" b2="138 KV" b3="199-K327" />
      <ContingencyEquipment Action="L" Type="LN" b1="19907" b2="138 KV" b3="199-KAN7" />
      <ContingencyEquipment Action="L" Type="LN" b1="19907" b2="138 KV" b3="199-KEN7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="K323" b2="138 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="K323" b2="138 KV" b3="2-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102414</SeqNum>
    <Name>L138.K323-19906-Kensington-Kankakee.19906</Name>
    <LastEdit Timestamp="2025-11-30T18:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CL" Type="DIS" b1="157 KANK" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="157 KANK" b2="138 KV" b3="L19906CS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="199 KENS" b2="138 KV" b3="L19906" />
      <ContingencyEquipment Action="L" Type="LN" b1="19906" b2="138 KV" b3="199-K326" />
      <ContingencyEquipment Action="L" Type="LN" b1="19906" b2="138 KV" b3="199-KAN6" />
      <ContingencyEquipment Action="L" Type="LN" b1="19906" b2="138 KV" b3="199-KEN6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="K323" b2="138 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="K323" b2="138 KV" b3="6-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102419</SeqNum>
    <Name>230/34.Takoma.027-6T</Name>
    <LastEdit Timestamp="2025-11-18T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TAKOMA" b2="230 KV" b3="027-6T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="3C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="34 KV" b3="6TS2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="34 KV" b3="6TS4B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102420</SeqNum>
    <Name>L345.GordonRoad-PrinceTown</Name>
    <LastEdit Timestamp="2025-09-12T16:47:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONRD" b2="345 KV" b3="G220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GORDONRD" b2="345 KV" b3="G230" />
      <ContingencyEquipment Action="L" Type="LN" b1="GORDONRD" b2="345 KV" b3="GOR-PRIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINCTWN" b2="345 KV" b3="G220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINCTWN" b2="345 KV" b3="G230" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102421</SeqNum>
    <Name>345/138.Bedford2.T5</Name>
    <LastEdit Timestamp="2025-11-18T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD2" b2="345 KV" b3="06B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD2" b2="138 KV" b3="3455" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEDFORD2" b2="345 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD2" b2="345 KV" b3="B517" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102422</SeqNum>
    <Name>345/138.Bedford2.T7</Name>
    <LastEdit Timestamp="2024-11-19T16:23:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD2" b2="345 KV" b3="17B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD2" b2="138 KV" b3="3457" />
      <ContingencyEquipment Action="X" Type="XF" b1="BEDFORD2" b2="345 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEDFORD2" b2="345 KV" b3="B721" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102424</SeqNum>
    <Name>L230.Monocacy-WestJefferson-Doubs</Name>
    <LastEdit Timestamp="2025-11-18T15:44:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ3 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBS" b2="230 KV" b3="DOU-WJEF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONOCACY" b2="230 KV" b3="DOUBS" />
      <ContingencyEquipment Action="L" Type="LN" b1="MONOCACY" b2="230 KV" b3="MON-WJEF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WJEFERSN" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WJEFERSN" b2="230 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102426</SeqNum>
    <Name>L69.Stuart-Raven-BrownHill-Poplar-Copeland</Name>
    <LastEdit Timestamp="2026-05-08T15:31:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08STUART" b2="69 KV" b3="716" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENTONVI" b2="69 KV" b3="BEN-POPL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENTONVI" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BENTONVI" b2="69 KV" b3="XT1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BROWNHIL" b2="69 KV" b3="ADAMS" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROWNHIL" b2="69 KV" b3="BRO-POPL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPELAND" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPELAND" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="COPELAND" b2="69 KV" b3="COP-POPL" />
      <ContingencyEquipment Action="L" Type="LN" b1="08STUART" b2="69 KV" b3="08S-RAVE" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROWNHIL" b2="69 KV" b3="BRO-RAV" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RAVEN" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102430</SeqNum>
    <Name>138/69.SouthBend.T6</Name>
    <LastEdit Timestamp="2025-11-18T15:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SBENDAEP" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="X" Type="XF" b1="SBENDAEP" b2="138 KV" b3="TR6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBENDAEP" b2="138 KV" b3="XT6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102439</SeqNum>
    <Name>L69.BiersRun-Towhees-Lattavil-Buckskin</Name>
    <LastEdit Timestamp="2024-09-12T16:46:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="69 KV" b3="K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIERSRUN" b2="69 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKSKIN" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUCKSKIN" b2="69 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKSKIN" b2="69 KV" b3="BUC-LAT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LATTAVIL" b2="69 KV" b3="LAT-TOWH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LATTAVIL" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIERSRUN" b2="69 KV" b3="BIE-TOWH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TOWHEES" b2="69 KV" b3="PAINTCRE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102440</SeqNum>
    <Name>345/69.Clinton3.BK-E</Name>
    <LastEdit Timestamp="2025-11-21T12:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CLINTON3" b2="345 KV" b3="BK-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON3" b2="345 KV" b3="EE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON3" b2="69 KV" b3="HE-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON3" b2="69 KV" b3="HE-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON3" b2="345 KV" b3="HE-CC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102441</SeqNum>
    <Name>PuddingRidge.OAKTRASP</Name>
    <LastEdit Timestamp="2025-11-24T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PUDDNRID" b2="230 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUDDNRID" b2="230 KV" b3="OAKTRACB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PUDDNRID" b2="34.5 KV" b3="OAKTRASP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102452</SeqNum>
    <Name>230/69.NorthHershey.TR3</Name>
    <LastEdit Timestamp="2025-11-07T09:25:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NHERSHEY" b2="230 KV" b3="B12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHERSHEY" b2="230 KV" b3="B18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHERSHEY" b2="69 KV" b3="B93" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHERSHEY" b2="69 KV" b3="B9_TEMP" />
      <ContingencyEquipment Action="X" Type="XF" b1="NHERSHEY" b2="230 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102453</SeqNum>
    <Name>L115.Poe-NewBohemia-BakersPondDP-Harrell.106</Name>
    <LastEdit Timestamp="2025-12-05T12:07:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAKRSPDP" b2="115 KV" b3="106AB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BAKRSPDP" b2="115 KV" b3="BAK-HARR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BAKRSPDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRELL" b2="115 KV" b3="10642-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRELL" b2="115 KV" b3="10642-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NBOHEMDP" b2="115 KV" b3="106A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NBOHEMDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NBOHMSUB" b2="115 KV" b3="106A2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="NBOHMSUB" b2="115 KV" b3="SC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POE" b2="115 KV" b3="10652" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102454</SeqNum>
    <Name>L115.Harrell-BellAve.1057</Name>
    <LastEdit Timestamp="2025-12-04T16:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELLAVE" b2="115 KV" b3="105795" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BELLAVE" b2="115 KV" b3="23T1057_" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLAVE" b2="115 KV" b3="BEL-HARR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRELL" b2="115 KV" b3="105742-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRELL" b2="115 KV" b3="105742-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102455</SeqNum>
    <Name>DTX138.Dameron.T3</Name>
    <LastEdit Timestamp="2025-12-10T16:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAMERON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAMERON" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAMERON" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102457</SeqNum>
    <Name>161/69.RusselCo.XF186</Name>
    <LastEdit Timestamp="2025-11-24T10:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSELCO" b2="161 KV" b3="CB1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RUSSELCO" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="X" Type="XF" b1="RUSSELCO" b2="161 KV" b3="XF186" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102458</SeqNum>
    <Name>138/34.DeerCreek.T1 + BigPlain2.SP</Name>
    <LastEdit Timestamp="2025-11-24T10:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCR" b2="34.5 KV" b3="BIGPL2CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DEERCR" b2="34.5 KV" b3="BIGPL2SP" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DEERCR" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCR" b2="34.5 KV" b3="CAP1CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DEERCR" b2="34.5 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCR" b2="34.5 KV" b3="CAP2CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="DEERCR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCR" b2="138 KV" b3="T1_HCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102461</SeqNum>
    <Name>L115.Chestnut-Meadows.110537</Name>
    <LastEdit Timestamp="2025-12-19T11:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTNUT" b2="115 KV" b3="527-537" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTNUT" b2="115 KV" b3="CHE-MEA2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MEADOWBC" b2="115 KV" b3="1TR537" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MEADOWBC" b2="115 KV" b3="2TR536" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MEADOWBC" b2="115 KV" b3="2TR537" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102462</SeqNum>
    <Name>L115.Chestnut-Frederick-ViaductAve-Pumphrey.110527</Name>
    <LastEdit Timestamp="2025-12-01T13:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTNUT" b2="115 KV" b3="110527CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTNUT" b2="115 KV" b3="CHE-FRE7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRED BC" b2="115 KV" b3="1_4TR27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRED BC" b2="115 KV" b3="2_3TR27" />
      <ContingencyEquipment Action="CL" Type="CB" b1="FRED BC" b2="115 KV" b3="2_3TR28" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRED BC" b2="115 KV" b3="FRE-VIA7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="110527" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUMPHREY" b2="115 KV" b3="527_522" />
      <ContingencyEquipment Action="L" Type="LN" b1="PUMPHREY" b2="115 KV" b3="PUM-VIA7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VIADUCAV" b2="115 KV" b3="527_1XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102468</SeqNum>
    <Name>138/69.Middle.T3</Name>
    <LastEdit Timestamp="2025-11-26T11:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MIDD AE" b2="138 KV" b3="MID #3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD AE" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDD AE" b2="69 KV" b3="XFMROCBE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102469</SeqNum>
    <Name>L69.Lewis-FAATC-Lenox.0721</Name>
    <LastEdit Timestamp="2025-12-03T11:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="FAATC" b2="69 KV" b3="0721-3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="FAATC" b2="69 KV" b3="76462" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAATC" b2="69 KV" b3="FAA-LEN" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAATC" b2="69 KV" b3="FAA-LEW1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FAATC" b2="69 KV" b3="LOAD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LENOX AE" b2="69 KV" b3="OCB L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEWIS" b2="69 KV" b3="R" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102474</SeqNum>
    <Name>138/25.OakHall.T1</Name>
    <LastEdit Timestamp="2026-06-01T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="180" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKHALL" b2="138 KV" b3="184" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="OAKHALL" b2="25 KV" b3="3239" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKHALL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKHALL" b2="25 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102488</SeqNum>
    <Name>Pondtown.SP1</Name>
    <LastEdit Timestamp="2025-11-30T18:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PONDTOWN" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PONDTOWN" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PONDTOWN" b2="34.5 KV" b3="PONDTSP1" />
      <ContingencyEquipment Action="S" Type="SD" b1="PONDTOWN" b2="138 KV" b3="SD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="PONDTOWN" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102489</SeqNum>
    <Name>Pondtown.SP2</Name>
    <LastEdit Timestamp="2025-11-30T18:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PONDTOWN" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PONDTOWN" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PONDTOWN" b2="34.5 KV" b3="PONDTSP2" />
      <ContingencyEquipment Action="S" Type="SD" b1="PONDTOWN" b2="138 KV" b3="SD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="PONDTOWN" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102490</SeqNum>
    <Name>L138.Sorenson-Illinois</Name>
    <LastEdit Timestamp="2025-11-30T18:08:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ILLINOIS" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="ILLINOIS" b2="138 KV" b3="ILL-SOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="M1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102491</SeqNum>
    <Name>L138.DeerCreek-Fisherbo</Name>
    <LastEdit Timestamp="2025-11-26T11:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEERCREE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEERCREE" b2="138 KV" b3="DEE-FISH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FISHERBO" b2="138 KV" b3="B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102496</SeqNum>
    <Name>L230.Clover-BlackWalnut.2068</Name>
    <LastEdit Timestamp="2025-09-18T16:54:43" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKWAL" b2="230 KV" b3="206822" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKWAL" b2="230 KV" b3="20682204" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKWAL" b2="230 KV" b3="BLA-CLOV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="206812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G1T2068" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102497</SeqNum>
    <Name>L230.Edmonson-BlackWalnut.2204</Name>
    <LastEdit Timestamp="2025-09-18T16:55:02" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKWAL" b2="230 KV" b3="20682204" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKWAL" b2="230 KV" b3="220422" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKWAL" b2="230 KV" b3="BLA-EDMO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDMONSON" b2="230 KV" b3="22042250" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDMONSON" b2="230 KV" b3="220482" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102498</SeqNum>
    <Name>RAS.L230.Edmonson-SedgeHill.2250 + Clover.U2</Name>
    <LastEdit Timestamp="2026-02-11T06:39:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="25 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G2TL9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOVER" b2="7 KV" b3="SS2LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDMONSON" b2="230 KV" b3="22042250" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDMONSON" b2="230 KV" b3="225082" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDMONSON" b2="230 KV" b3="EDM-SEDG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="230 KV" b3="H1T2250" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="230 KV" b3="H2T2250" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102499</SeqNum>
    <Name>RAS.L230.Edmonson-BlackWalnut.2204 + Clover.U2</Name>
    <LastEdit Timestamp="2026-02-11T06:40:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKWAL" b2="230 KV" b3="20682204" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKWAL" b2="230 KV" b3="220422" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKWAL" b2="230 KV" b3="BLA-EDMO" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="25 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G2TL9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOVER" b2="7 KV" b3="SS2LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDMONSON" b2="230 KV" b3="22042250" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDMONSON" b2="230 KV" b3="220482" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102500</SeqNum>
    <Name>L230.Edmonson-SedgeHill.2250</Name>
    <LastEdit Timestamp="2025-09-18T16:53:47" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDMONSON" b2="230 KV" b3="22042250" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDMONSON" b2="230 KV" b3="225082" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDMONSON" b2="230 KV" b3="EDM-SEDG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="230 KV" b3="H1T2250" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEDGEHIL" b2="230 KV" b3="H2T2250" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102505</SeqNum>
    <Name>L230.Ritchie-Waterfront.23016</Name>
    <LastEdit Timestamp="2025-12-03T11:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RITCHIE" b2="230 KV" b3="23016B" />
      <ContingencyEquipment Action="L" Type="LN" b1="RITCHIE" b2="230 KV" b3="RIT-WAT6" />
      <ContingencyEquipment Action="P" Type="XF" b1="WATERFRO" b2="230 KV" b3="23016-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="5BCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="5CCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102506</SeqNum>
    <Name>EastFayette.ArcheSP</Name>
    <LastEdit Timestamp="2025-12-04T16:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="E_FAYET" b2="34.5 KV" b3="ARCHESP" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="E_FAYET" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="X" Type="XF" b1="E_FAYET" b2="138 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E_FAYET" b2="138 KV" b3="HCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102507</SeqNum>
    <Name>138/69.Chatfield.T1</Name>
    <LastEdit Timestamp="2025-12-02T10:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHATFIEL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHATFIEL" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHATFIEL" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHATFIEL" b2="69 KV" b3="K" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHATFIEL" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102511</SeqNum>
    <Name>138.Lick.TR4</Name>
    <LastEdit Timestamp="2024-08-15T16:38:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LICK" b2="138 KV" b3="104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICK" b2="138 KV" b3="105" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102513</SeqNum>
    <Name>138/34.Hancock.T2</Name>
    <LastEdit Timestamp="2024-05-14T09:48:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HANCOCK" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK" b2="34 KV" b3="AE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102520</SeqNum>
    <Name>L115.Chestnut-Meadows.110536</Name>
    <LastEdit Timestamp="2025-12-24T10:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTNUT" b2="115 KV" b3="530-536" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MEADOWBC" b2="115 KV" b3="1TR537" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MEADOWBC" b2="115 KV" b3="2TR536" />
      <ContingencyEquipment Action="CL" Type="CB" b1="MEADOWBC" b2="13.8 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTNUT" b2="115 KV" b3="CHE-MEA1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MEADOWBC" b2="13.8 KV" b3="DUM3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102521</SeqNum>
    <Name>L115.Granite-Hollofield-Chestnut.110530/110528B</Name>
    <LastEdit Timestamp="2025-12-24T10:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CHESTNUT" b2="115 KV" b3="110530" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTNUT" b2="115 KV" b3="CHE-HOL8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="115 KV" b3="110530" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRANITE" b2="115 KV" b3="530_60A" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANITE" b2="115 KV" b3="GRA-HOL8" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="HOLLOFIE" b2="115 KV" b3="1-2 BUS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HOLLOFIE" b2="115 KV" b3="110-2H_S" />
      <ContingencyEquipment Action="S" Type="SD" b1="HOLLOFIE" b2="115 KV" b3="110528-B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102526</SeqNum>
    <Name>345/69.Clinton3.BK-W</Name>
    <LastEdit Timestamp="2025-12-11T09:14:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CLINTON3" b2="345 KV" b3="BK-W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON3" b2="69 KV" b3="HE-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON3" b2="69 KV" b3="HE-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON3" b2="345 KV" b3="HE-AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON3" b2="345 KV" b3="HE-FF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102527</SeqNum>
    <Name>L115.Pineglade-Paytes-Golddale-Spotsylvania</Name>
    <LastEdit Timestamp="2025-12-05T12:06:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GOLDDALE" b2="115 KV" b3="153B" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAYTESDP" b2="115 KV" b3="153B1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PAYTESDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PAYTESDP" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEGLAD" b2="115 KV" b3="104642" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEGLAD" b2="115 KV" b3="153T1046" />
      <ContingencyEquipment Action="L" Type="LN" b1="PAYTESTP" b2="115 KV" b3="PAY-PINE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="115 KV" b3="104672" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOLDDALE" b2="115 KV" b3="GOL-SPOS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPOTSLV" b2="115 KV" b3="WT1046" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102528</SeqNum>
    <Name>138/69.MoorePark.T3</Name>
    <LastEdit Timestamp="2025-12-10T16:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MOOREPAR" b2="138 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOOREPAR" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOOREPAR" b2="138 KV" b3="XT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102529</SeqNum>
    <Name>DTX.Conesville.SLATE2</Name>
    <LastEdit Timestamp="2026-05-18T15:48:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="138 KV" b3="2C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONESVIL" b2="138 KV" b3="2S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONESVIL" b2="138 KV" b3="FGD LD2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CONESVIL" b2="138 KV" b3="SLATE2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102530</SeqNum>
    <Name>L230.Waterfront-BuzzardPoint.23173</Name>
    <LastEdit Timestamp="2026-01-16T13:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="BUZZARD" b2="230 KV" b3="23173SR" />
      <ContingencyEquipment Action="P" Type="XF" b1="BUZZARD" b2="138 KV" b3="7T-PS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUZZARD" b2="138 KV" b3="7TSBCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUZZARD" b2="230 KV" b3="BUZ-WAT3" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUZZARD" b2="230 KV" b3="STAB-7-" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="6BCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="6CCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102531</SeqNum>
    <Name>BlackWalnut.FoxHouseSP</Name>
    <LastEdit Timestamp="2025-12-05T12:05:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKWAL" b2="230 KV" b3="206822" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKWAL" b2="230 KV" b3="220422" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKWAL" b2="34.5 KV" b3="FOXHOUCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BLACKWAL" b2="34.5 KV" b3="FOXHOUSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLACKWAL" b2="230 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKWAL" b2="230 KV" b3="GSU_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102533</SeqNum>
    <Name>L69.Haviland-NorthVanWert-VanWert</Name>
    <LastEdit Timestamp="2025-12-08T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAVILAND" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAVILAND" b2="69 KV" b3="HAV-NVA" />
      <ContingencyEquipment Action="L" Type="LN" b1="NVANWERT" b2="69 KV" b3="NVA-VAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NVANWERT" b2="69 KV" b3="VAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VANWERT" b2="69 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102534</SeqNum>
    <Name>L69.Haviland-LattyJct-Latty-Payne</Name>
    <LastEdit Timestamp="2025-12-08T10:43:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAVILAND" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="LATTY" b2="69 KV" b3="LAT-PAY" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LATTY" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAVILAND" b2="69 KV" b3="HAV-LAT" />
      <ContingencyEquipment Action="L" Type="LN" b1="LATTY" b2="69 KV" b3="LAT-LAT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LATTYJCT" b2="69 KV" b3="LATTY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAYNE" b2="69 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102535</SeqNum>
    <Name>L69.NDelphos-EDelphos-ElidaRoad-NorthSpencerville</Name>
    <LastEdit Timestamp="2025-12-10T16:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDELPHOS" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDELPHOS" b2="69 KV" b3="EDE-ELI" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIDARD" b2="69 KV" b3="ELI-NSP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELIDARD" b2="69 KV" b3="ELIDA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NDELPHOS" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDELPHOS" b2="69 KV" b3="EDE-NDE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NSPENCER" b2="69 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102536</SeqNum>
    <Name>L69.NDelphos-SDelphos-Delphos-NMiddlepoint-VanWert</Name>
    <LastEdit Timestamp="2025-12-10T16:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DELPHOS" b2="69 KV" b3="DEL-NMI" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELPHOS" b2="69 KV" b3="DEL-SDE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DELPHOS" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DELPHOS" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NDELPHOS" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NMIDDLEP" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="NDELPHOS" b2="69 KV" b3="NDE-SDE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SDELPHOS" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VANWERT" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="NMIDDLEP" b2="69 KV" b3="NMI-VAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102537</SeqNum>
    <Name>138/69.Wellington.T3</Name>
    <LastEdit Timestamp="2025-12-05T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLINGT" b2="69 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLINGT" b2="138 KV" b3="B64" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLINGT" b2="138 KV" b3="B67" />
      <ContingencyEquipment Action="X" Type="XF" b1="WELLINGT" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102538</SeqNum>
    <Name>138/69.Wellington.T4</Name>
    <LastEdit Timestamp="2025-12-05T09:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLINGT" b2="138 KV" b3="B61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLINGT" b2="138 KV" b3="B70" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLINGT" b2="69 KV" b3="B88" />
      <ContingencyEquipment Action="X" Type="XF" b1="WELLINGT" b2="138 KV" b3="TR4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102539</SeqNum>
    <Name>L138.Beaver-Brighton-Wellington</Name>
    <LastEdit Timestamp="2025-12-23T10:28:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="127" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVER" b2="138 KV" b3="BEA-BRIG" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIGTN" b2="138 KV" b3="BRI-WELL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRIGTN" b2="138 KV" b3="LD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLINGT" b2="138 KV" b3="B67" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WELLINGT" b2="138 KV" b3="B70" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102542</SeqNum>
    <Name>L345.Kansas-Sugar Creek</Name>
    <LastEdit Timestamp="2024-08-16T10:34:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08SCRK_M" b2="345 KV" b3="38-45" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08SCRK_M" b2="345 KV" b3="45-13" />
      <ContingencyEquipment Action="L" Type="LN" b1="KANSAS 3" b2="345 KV" b3="KAN-SUGA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANSAS 3" b2="345 KV" b3="V33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KANSAS 3" b2="345 KV" b3="V35" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102543</SeqNum>
    <Name>L138.Marktown - Amoco - Sheffield (NIPS)</Name>
    <LastEdit Timestamp="2025-11-17T11:42:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="17MRKTWN" b2="138 KV" b3="17M-AMO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17MRKTWN" b2="138 KV" b3="69N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17MRKTWN" b2="138 KV" b3="69S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMOCOTP" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="AMOCOTP" b2="138 KV" b3="LB12_MO" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="AMOCOTP" b2="138 KV" b3="LB13_MO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="138 KV" b3="7778" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="138 KV" b3="7793" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHEFFILD" b2="138 KV" b3="SHE-AMO1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102547</SeqNum>
    <Name>L230.Dawkins-Liberty.2246</Name>
    <LastEdit Timestamp="2025-12-10T16:19:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAWKINSB" b2="230 KV" b3="224642" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAWKINSB" b2="230 KV" b3="DAW-LIB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAWKINSB" b2="230 KV" b3="VT2246" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="230 KV" b3="224612-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="230 KV" b3="224612-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102548</SeqNum>
    <Name>DTX.Dawkins.LD1</Name>
    <LastEdit Timestamp="2025-12-10T16:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAWKINSB" b2="230 KV" b3="216342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAWKINSB" b2="230 KV" b3="224642" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAWKINSB" b2="230 KV" b3="LD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102549</SeqNum>
    <Name>DTX.Dawkins.LD2</Name>
    <LastEdit Timestamp="2025-12-10T16:21:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAWKINSB" b2="230 KV" b3="LD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAWKINSB" b2="230 KV" b3="VT2246" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAWKINSB" b2="230 KV" b3="ZT2163" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102550</SeqNum>
    <Name>L138.37Natoma-78FranklinPark.3705 G SPOG 2-48</Name>
    <LastEdit Timestamp="2025-12-10T17:55:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="37 NATOM" b2="138 KV" b3="3705" />
      <ContingencyEquipment Action="CL" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT2121CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT722 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT726 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="138 KV" b3="BT1-8CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="138 KV" b3="BT5-8CB" />
      <ContingencyEquipment Action="P" Type="XF" b1="78 FRANK" b2="138 KV" b3="P3705-1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="78 FRANK" b2="138 KV" b3="P3705BD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="78 FRANK" b2="138 KV" b3="P3705BYD" />
      <ContingencyEquipment Action="X" Type="XF" b1="78 FRANK" b2="138 KV" b3="P3705T38" />
      <ContingencyEquipment Action="X" Type="XF" b1="78 FRANK" b2="138 KV" b3="Z3705T38" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102565</SeqNum>
    <Name>L69.Siegfried-Hauto.1</Name>
    <LastEdit Timestamp="2025-12-11T09:51:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ASHFIEPL" b2="69 KV" b3="2601" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASHFIEPL" b2="69 KV" b3="ASH-EPT1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASHFIEPL" b2="69 KV" b3="ASH-LAND" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ASHFIEPL" b2="69 KV" b3="ASH1LOAD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EPALMTAP" b2="69 KV" b3="1217" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAUTO" b2="69 KV" b3="2294" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAUTO" b2="69 KV" b3="HAU-PEN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANSFORD" b2="69 KV" b3="LAN-PENN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LANSFORD" b2="69 KV" b3="LANSLOAD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PENN_SP" b2="69 KV" b3="2299" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENN_SP" b2="69 KV" b3="CB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENN_SP" b2="69 KV" b3="CB3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PENN_SP" b2="69 KV" b3="GREEN2SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PENN_SP" b2="69 KV" b3="GREENSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="FRAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="NAZ1FRC1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SIEGFRIE" b2="69 KV" b3="SIE-TRE1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SSLATING" b2="69 KV" b3="DUMG1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPALMTAP" b2="69 KV" b3="EPT-SSL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SSLATING" b2="69 KV" b3="SSL-TRE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SSLATING" b2="69 KV" b3="SSL1LOAD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TREICHLE" b2="69 KV" b3="1211" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TREICHLE" b2="69 KV" b3="TR12LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102566</SeqNum>
    <Name>L69.Siegfried-Hauto.2</Name>
    <LastEdit Timestamp="2025-12-11T09:53:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ASHFIEPL" b2="69 KV" b3="2601" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASHFIEPL" b2="69 KV" b3="ASH-EPT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASHFIEPL" b2="69 KV" b3="ASH-PENN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ASHFIEPL" b2="69 KV" b3="ASH2LOAD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EPALMTAP" b2="69 KV" b3="1218" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HAUTO" b2="69 KV" b3="2295" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAUTO" b2="69 KV" b3="HAU-PEN2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PENN_SP" b2="69 KV" b3="2299" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="FRAC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="NAZ2FRC2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SIEGFRIE" b2="69 KV" b3="SIE-TRE2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SSLATING" b2="69 KV" b3="DUMG1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPALMTAP" b2="69 KV" b3="EPT-SSL2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SSLATING" b2="69 KV" b3="SSL-TRE2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SSLATING" b2="69 KV" b3="SSL2LOAD" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TREICHLE" b2="69 KV" b3="1211" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102567</SeqNum>
    <Name>DTX138.Innovation.CMH704</Name>
    <LastEdit Timestamp="2025-12-10T16:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INNOVATI" b2="138 KV" b3="CMH704" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H002F2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H002F5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102568</SeqNum>
    <Name>DTX138.Innovation.CMH703</Name>
    <LastEdit Timestamp="2025-12-10T16:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INNOVATI" b2="138 KV" b3="CMH703" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H002G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H002G5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102574</SeqNum>
    <Name>230/69.Pentagon.TX2</Name>
    <LastEdit Timestamp="2025-12-11T09:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="230 KV" b3="H222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENTAGON" b2="69 KV" b3="L222" />
      <ContingencyEquipment Action="X" Type="XF" b1="PENTAGON" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102575</SeqNum>
    <Name>L69.Haviland-Paulding</Name>
    <LastEdit Timestamp="2025-12-11T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HAVILAND" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="L" Type="LN" b1="HAVILAND" b2="69 KV" b3="HAV-PAU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PAULDING" b2="69 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102576</SeqNum>
    <Name>Powell.SP</Name>
    <LastEdit Timestamp="2024-08-20T07:47:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HENDRICK" b2="230 KV" b3="221762" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HENDRICK" b2="230 KV" b3="224162" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HENDRICK" b2="230 KV" b3="52" />
      <ContingencyEquipment Action="X" Type="XF" b1="HENDRICK" b2="230 KV" b3="GSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HENDRICK" b2="34.5 KV" b3="POWELLSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102577</SeqNum>
    <Name>PineyCreek.SP</Name>
    <LastEdit Timestamp="2025-12-11T09:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EDMONSON" b2="230 KV" b3="220482" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDMONSON" b2="230 KV" b3="225082" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDMONSON" b2="230 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDMONSON" b2="230 KV" b3="GSU_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDMONSON" b2="34.5 KV" b3="PINEYCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EDMONSON" b2="34.5 KV" b3="PINEYCSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102578</SeqNum>
    <Name>L345.Roberts-Cosgray</Name>
    <LastEdit Timestamp="2026-04-24T08:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COSGRAY" b2="345 KV" b3="H001X2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COSGRAY" b2="345 KV" b3="H001X5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTS2" b2="345 KV" b3="A CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="COSGRAY" b2="345 KV" b3="COS-ROBE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102579</SeqNum>
    <Name>L345.Cosgray-Hayden</Name>
    <LastEdit Timestamp="2025-12-11T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COSGRAY" b2="345 KV" b3="H001W5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COSGRAY" b2="345 KV" b3="H001W8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYDEN" b2="345 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COSGRAY" b2="345 KV" b3="COS-HAYD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYDEN" b2="345 KV" b3="D1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102581</SeqNum>
    <Name>L115.SpanishGrove-JonesStore-Jeffress.1058</Name>
    <LastEdit Timestamp="2025-02-21T15:05:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFRESS" b2="115 KV" b3="105852" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFRESS" b2="115 KV" b3="WT1058" />
      <ContingencyEquipment Action="L" Type="LN" b1="JEFFRESS" b2="115 KV" b3="JEF-JONE" />
      <ContingencyEquipment Action="L" Type="LN" b1="JONESTDP" b2="115 KV" b3="JON-SPGR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JONESTDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPANGRO" b2="115 KV" b3="10501058" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPANGRO" b2="115 KV" b3="105892" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102582</SeqNum>
    <Name>DTX.Dameron.T4</Name>
    <LastEdit Timestamp="2025-12-11T09:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAMERON" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAMERON" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAMERON" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102583</SeqNum>
    <Name>L138.Kileville-Amlin</Name>
    <LastEdit Timestamp="2026-01-27T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMLIN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMLIN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMLIN" b2="138 KV" b3="AML-KILE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KILEVILL" b2="138 KV" b3="H002N5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KILEVILL" b2="138 KV" b3="H002N8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102587</SeqNum>
    <Name>L345.HardinCounty-GlendaleSouth</Name>
    <LastEdit Timestamp="2025-12-16T12:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDALS" b2="345 KV" b3="912" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDALS" b2="345 KV" b3="914" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARDIN_C" b2="345 KV" b3="GLEN-HAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="345 KV" b3="CB904" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDIN_C" b2="345 KV" b3="CB914" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102588</SeqNum>
    <Name>345/138.GlendaleSouth.TR1</Name>
    <LastEdit Timestamp="2025-12-12T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDALS" b2="138 KV" b3="712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDALS" b2="138 KV" b3="718" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDALS" b2="345 KV" b3="912" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDALS" b2="345 KV" b3="918" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLENDALS" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102589</SeqNum>
    <Name>345/138.GlendaleSouth.TR2</Name>
    <LastEdit Timestamp="2025-12-12T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDALS" b2="138 KV" b3="722" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDALS" b2="138 KV" b3="728" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDALS" b2="345 KV" b3="922" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDALS" b2="345 KV" b3="928" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLENDALS" b2="345 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102591</SeqNum>
    <Name>L115.Oakdale-Goudey</Name>
    <LastEdit Timestamp="2025-12-12T15:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOUDEY" b2="115 KV" b3="93902" />
      <ContingencyEquipment Action="L" Type="LN" b1="GOUDEY" b2="115 KV" b3="GOU-OAK9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKDALE" b2="115 KV" b3="939" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKDALE" b2="115 KV" b3="93922" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102593</SeqNum>
    <Name>L230.Heathcote-YoungsBranch</Name>
    <LastEdit Timestamp="2025-12-24T10:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATHCOT" b2="230 KV" b3="21842251" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HEATHCOT" b2="230 KV" b3="225102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YOUNGSBR" b2="230 KV" b3="225142" />
      <ContingencyEquipment Action="L" Type="LN" b1="HEATHCOT" b2="230 KV" b3="HEA-YOUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YOUNGSBR" b2="230 KV" b3="YT2251" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102595</SeqNum>
    <Name>L765.Rockport-RockportWorks.3</Name>
    <LastEdit Timestamp="2025-12-24T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ROCKPOR2" b2="765 KV" b3="ROC-ROC3" />
      <ContingencyEquipment Action="X" Type="XF" b1="ROCKPWKS" b2="765 KV" b3="8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPWKS" b2="138 KV" b3="T8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKPWKS" b2="765 KV" b3="TB8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102604</SeqNum>
    <Name>Axton.SP</Name>
    <LastEdit Timestamp="2026-01-08T09:10:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="AXTONAEP" b2="34.5 KV" b3="AXTONSP" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="AXTONAEP" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AXTONAEP" b2="138 KV" b3="HV1" />
      <ContingencyEquipment Action="X" Type="XF" b1="AXTONAEP" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102605</SeqNum>
    <Name>DTX69.HighStreet.SJGAS</Name>
    <LastEdit Timestamp="2025-12-26T13:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHST" b2="69 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHST" b2="69 KV" b3="M" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HIGHST" b2="69 KV" b3="SJGAS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102606</SeqNum>
    <Name>DTX138.Woodville.TR2</Name>
    <LastEdit Timestamp="2025-12-24T10:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVLTE" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVLTE" b2="138 KV" b3="B8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WOODVLTE" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102607</SeqNum>
    <Name>L138.Finley-Broadview</Name>
    <LastEdit Timestamp="2025-12-26T13:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADVW" b2="138 KV" b3="B69" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROADVW" b2="138 KV" b3="B70" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINLEY" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINLEY" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROADVW" b2="138 KV" b3="BRO-FIN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102613</SeqNum>
    <Name>L138.Roxana-MitchellYard (NIPS) </Name>
    <LastEdit Timestamp="2025-12-26T13:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="17ROXANA" b2="138 KV" b3="25" />
      <ContingencyEquipment Action="L" Type="LN" b1="MITCHYRD" b2="138 KV" b3="MIT-ROXA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHYRD" b2="138 KV" b3="25N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MITCHYRD" b2="138 KV" b3="25S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102617</SeqNum>
    <Name>WalnutRidge.WF2</Name>
    <LastEdit Timestamp="2025-12-26T13:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="980 WALN" b2="34.5 KV" b3="WALNT2CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="980 WALN" b2="34.5 KV" b3="WALNT2WF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102618</SeqNum>
    <Name>DTX69.Beckett.T1</Name>
    <LastEdit Timestamp="2025-12-26T13:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKETT" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKETT" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BECKETT" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102623</SeqNum>
    <Name>L230.Milton-Montour.2</Name>
    <LastEdit Timestamp="2024-07-07T08:32:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MILTON" b2="230 KV" b3="MIL-MON2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON" b2="230 KV" b3="MON2SUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON" b2="230 KV" b3="MONT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="MILT2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="MILTSAE2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102624</SeqNum>
    <Name>L115.Shillelagh-GreatBridge-Hickory.16</Name>
    <LastEdit Timestamp="2025-12-30T14:31:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HICKORY" b2="115 KV" b3="16A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRTBRIDG" b2="115 KV" b3="H142" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRTBRIDG" b2="115 KV" b3="H242" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRTBRIDG" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRTBRIDG" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="GRTBRIDG" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRTBRIDG" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HICKORY" b2="115 KV" b3="1632" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHILLAGH" b2="115 KV" b3="105392" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHILLAGH" b2="115 KV" b3="74T1053" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRTBRIDG" b2="115 KV" b3="GRT-SHIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102625</SeqNum>
    <Name>Shillelagh.SP</Name>
    <LastEdit Timestamp="2026-01-08T09:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SHILLAGH" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHILLAGH" b2="115 KV" b3="SHILLACB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SHILLAGH" b2="34.5 KV" b3="SHILLASP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102634</SeqNum>
    <Name>L69.Seville-Seville Tap</Name>
    <LastEdit Timestamp="2025-12-29T11:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEVILL" b2="69 KV" b3="B53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEVILL" b2="69 KV" b3="B54" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEVILL" b2="69 KV" b3="SEV-SEVT" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SEVILLTP" b2="69 KV" b3="DUM2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102635</SeqNum>
    <Name>L69.Seville-Acme Hill</Name>
    <LastEdit Timestamp="2026-01-06T17:09:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ACMEHILL" b2="69 KV" b3="DUMG1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ACMEHILL" b2="69 KV" b3="ACM-SEV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEVILL" b2="69 KV" b3="B21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEVILL" b2="69 KV" b3="B55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEVILL" b2="69 KV" b3="CS1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SEVILL" b2="69 KV" b3="MOBILE21" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102636</SeqNum>
    <Name>L138.AmblerRdg-ThorofareCrk-Jarrett</Name>
    <LastEdit Timestamp="2025-12-29T10:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMBLERR" b2="138 KV" b3="AMB-THO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMBLERR" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JARRETT" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="JARRETT" b2="138 KV" b3="JAR-THOR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THOROFSS" b2="138 KV" b3="BROADRUN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THOROFSS" b2="138 KV" b3="COBB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THOROFSS" b2="138 KV" b3="MORRISBR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102637</SeqNum>
    <Name>L138.Jarrett-Flatwood-Coco </Name>
    <LastEdit Timestamp="2025-12-30T11:53:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COCO" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COCO" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="COCO" b2="138 KV" b3="COC-FLA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLATWOOD" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FLATWOOD" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JARRETT" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="FLATWOOD" b2="138 KV" b3="FLA-JARR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102639</SeqNum>
    <Name>L345.Batesville-Ghent+345/138.Batesville.3</Name>
    <LastEdit Timestamp="2025-12-30T11:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BATESVIL" b2="345 KV" b3="3" />
      <ContingencyEquipment Action="L" Type="LN" b1="BATESVIL" b2="345 KV" b3="BAT-GHE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATESVIL" b2="138 KV" b3="T13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_942" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GHENT_LG" b2="345 KV" b3="B165_944" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102640</SeqNum>
    <Name>L138.Strasburg-BuffaloMarsh (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-25T12:55:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFALOM" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFALOM" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUFFALOM" b2="138 KV" b3="BUF-STRA" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="STRASBUR" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STRASBUR" b2="138 KV" b3="CAP2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102641</SeqNum>
    <Name>L138.Halfway-Marlowe (Sctnlz)</Name>
    <LastEdit Timestamp="2025-12-30T14:33:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="HALFWAY" b2="138 KV" b3="MARLOWE" />
      <ContingencyEquipment Action="L" Type="LN" b1="HALFWAY" b2="138 KV" b3="HAL-MAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARLOWE" b2="138 KV" b3="HALFWAY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102642</SeqNum>
    <Name>L138.Halfway-Paramount (Sctnlz)</Name>
    <LastEdit Timestamp="2025-12-30T14:33:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HALFWAY" b2="138 KV" b3="HAL-PAR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HALFWAY" b2="138 KV" b3="PARAMOUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARAMOUN" b2="138 KV" b3="BUS_TIE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102643</SeqNum>
    <Name>L138.Paramount-Reid.RI-2 (Sctnlz)</Name>
    <LastEdit Timestamp="2025-12-30T14:34:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="PARAMOUN" b2="138 KV" b3="PAR-REI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="PARAMOUN" b2="138 KV" b3="REID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REID" b2="138 KV" b3="PARAMOUN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102644</SeqNum>
    <Name>L115.NorthernNeck-MoonCrnr.1059</Name>
    <LastEdit Timestamp="2026-02-24T23:01:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOONCRNR" b2="115 KV" b3="10591073" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOONCRNR" b2="115 KV" b3="10591078" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOONCRNR" b2="115 KV" b3="65T1059" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOONCRNR" b2="115 KV" b3="MOO-NRTH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="115 KV" b3="105952" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="115 KV" b3="L4T1059" />
      <ContingencyEquipment Action="X" Type="XF" b1="NRTHNECK" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NRTHNECK" b2="35 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102648</SeqNum>
    <Name>Pineglade.SP</Name>
    <LastEdit Timestamp="2026-04-28T08:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="PINEGLAD" b2="34.5 KV" b3="PINEGLSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="PINEGLAD" b2="115 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEGLAD" b2="115 KV" b3="T1HS_CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PINEGLAD" b2="115 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEGLAD" b2="115 KV" b3="T2HS_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102649</SeqNum>
    <Name>L138.Mechanicstown-Millville</Name>
    <LastEdit Timestamp="2026-01-08T09:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MECHATWN" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MECHATWN" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="MECHATWN" b2="138 KV" b3="MEC-MILL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLVILL" b2="138 KV" b3="FEAGANSM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102650</SeqNum>
    <Name>Mechatwn.Blakes.SP</Name>
    <LastEdit Timestamp="2026-01-20T18:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MECHATWN" b2="138 KV" b3="BLAKEGSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MECHATWN" b2="34.5 KV" b3="BLAKESP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MECHATWN" b2="138 KV" b3="CB1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102651</SeqNum>
    <Name>DTX230.Montour.TR10</Name>
    <LastEdit Timestamp="2025-12-30T13:16:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="BAY7_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="SAEG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="SAEG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="SUSQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTOUR" b2="230 KV" b3="SUSQ_10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONTOUR" b2="230 KV" b3="T40" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MONTOUR" b2="230 KV" b3="TR10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102653</SeqNum>
    <Name>Todd.SP</Name>
    <LastEdit Timestamp="2026-03-27T10:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TODD" b2="69 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODD" b2="69 KV" b3="GSU_HSCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TODD" b2="34.5 KV" b3="RICHFICB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="TODD" b2="34.5 KV" b3="RICHFISP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102659</SeqNum>
    <Name>138/34.Holston.T2-XF</Name>
    <LastEdit Timestamp="2025-12-30T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLSTON" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLSTON" b2="34.5 KV" b3="K1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOLSTON" b2="34.5 KV" b3="L" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOLSTON" b2="138 KV" b3="T2-XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102660</SeqNum>
    <Name>L138.Putnam-Streator</Name>
    <LastEdit Timestamp="2026-04-27T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="61 STREA" b2="138 KV" b3="L6101 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="PUTN" b2="138 KV" b3="PUT-STRE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102662</SeqNum>
    <Name>L138.Kewanee-Putnam</Name>
    <LastEdit Timestamp="2025-12-31T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="74 KEWAN" b2="138 KV" b3="KEW-PUTN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="74 KEWAN" b2="138 KV" b3="L7404_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102667</SeqNum>
    <Name>L138.Corbin-Mazon.7713</Name>
    <LastEdit Timestamp="2025-12-31T11:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="77 MAZON" b2="138 KV" b3="77197713" />
      <ContingencyEquipment Action="L" Type="LN" b1="CRBN" b2="138 KV" b3="CRB-MAZO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRBN" b2="138 KV" b3="H41" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRBN" b2="138 KV" b3="H43" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102669</SeqNum>
    <Name>L138.Putnam-EskimoTap.1757</Name>
    <LastEdit Timestamp="2026-01-02T11:19:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ESK TAP3" b2="138 KV" b3="K TAP 43" />
      <ContingencyEquipment Action="L" Type="LN" b1="ESK TAP3" b2="138 KV" b3="ESK-PUTN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102670</SeqNum>
    <Name>L138.Hickock-Putnam.1556</Name>
    <LastEdit Timestamp="2025-12-31T11:33:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HKOK" b2="138 KV" b3="H5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HKOK" b2="138 KV" b3="H7" />
      <ContingencyEquipment Action="L" Type="LN" b1="HKOK" b2="138 KV" b3="HKO-PUTN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H55" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102673</SeqNum>
    <Name>Harrell.WaverlySP</Name>
    <LastEdit Timestamp="2025-12-31T11:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HARRELL" b2="115 KV" b3="GSU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRELL" b2="115 KV" b3="GSU1_CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HARRELL" b2="34.5 KV" b3="WAVRLYSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102674</SeqNum>
    <Name>L345.Tiffin-Hills (MEC)</Name>
    <LastEdit Timestamp="2025-12-31T11:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLS  6" b2="345 KV" b3="974" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLS  6" b2="345 KV" b3="984" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLS  6" b2="345 KV" b3="62276622" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFIN 6" b2="345 KV" b3="ICK944" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102675</SeqNum>
    <Name>138/34.5.Finley.T1</Name>
    <LastEdit Timestamp="2026-01-02T11:11:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="FINLEY" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="FINLEY" b2="34.5 KV" b3="CAP2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="FINLEY" b2="34.5 KV" b3="MADSNFSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="FINLEY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINLEY" b2="138 KV" b3="T1_HCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102677</SeqNum>
    <Name>L345.Beatty-Chenoweth</Name>
    <LastEdit Timestamp="2026-01-08T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="345 KV" b3="302C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEATTY" b2="345 KV" b3="302W" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEATTY" b2="345 KV" b3="BEA-CHEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHENOWET" b2="345 KV" b3="H005V8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHENOWET" b2="345 KV" b3="H005W2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102678</SeqNum>
    <Name>L230.Belmont-CochranMill-GooseCreek.2286</Name>
    <LastEdit Timestamp="2024-08-30T09:59:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLMNTDOM" b2="230 KV" b3="21782286" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLMNTDOM" b2="230 KV" b3="21802286" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLMNTDOM" b2="230 KV" b3="BEL-COCH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRE" b2="230 KV" b3="227T2286" />
      <ContingencyEquipment Action="L" Type="LN" b1="COCHRANM" b2="230 KV" b3="COC-GOOS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRE" b2="230 KV" b3="L1T2286" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102679</SeqNum>
    <Name>L138.Hennepin-Putnam.1765</Name>
    <LastEdit Timestamp="2024-08-16T10:43:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HENNEPIN" b2="138 KV" b3="1516" />
      <ContingencyEquipment Action="L" Type="LN" b1="HENNEPIN" b2="138 KV" b3="HEN-PUT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H33" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102680</SeqNum>
    <Name>L115.GittsRun-PHGlatfelter.995</Name>
    <LastEdit Timestamp="2026-01-08T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GITTSRUN" b2="115 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GITTSRUN" b2="115 KV" b3="B9" />
      <ContingencyEquipment Action="L" Type="LN" b1="GITTSRUN" b2="115 KV" b3="GIT-PHG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHGLATFE" b2="115 KV" b3="B99512" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102681</SeqNum>
    <Name>DTX138.GittsRun3</Name>
    <LastEdit Timestamp="2026-01-08T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GITTSRUN" b2="115 KV" b3="3 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GITTSRUN" b2="115 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GITTSRUN" b2="115 KV" b3="B9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102682</SeqNum>
    <Name>L138.Bluefield-Hockman</Name>
    <LastEdit Timestamp="2026-01-08T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLUEFIEL" b2="138 KV" b3="BLU-HOCK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUEFIEL" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BLUEFIEL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOCKMAN" b2="138 KV" b3="A000B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOCKMAN" b2="138 KV" b3="A000B5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOCKMAN" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102683</SeqNum>
    <Name>DTX138.JKSmith.JKSMITHP</Name>
    <LastEdit Timestamp="2026-01-08T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB802" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JKSMT_EK" b2="138 KV" b3="CB90T" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JKSMT_EK" b2="138 KV" b3="JKSMITHP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102684</SeqNum>
    <Name>Harrell.Waverly2SP</Name>
    <LastEdit Timestamp="2026-01-08T09:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HARRELL" b2="115 KV" b3="GSU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRELL" b2="115 KV" b3="GSU2_CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HARRELL" b2="34.5 KV" b3="WAVRL2SP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102690</SeqNum>
    <Name>DTX138.45Jefferson.TR75</Name>
    <LastEdit Timestamp="2026-01-08T09:43:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT8-9 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="45 JEFFE" b2="138 KV" b3="BT9-10CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="45 JEFFE" b2="138 KV" b3="TR75_12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102695</SeqNum>
    <Name>L345.Hugh-Zachary</Name>
    <LastEdit Timestamp="2024-08-16T10:46:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUGH" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUGH" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUGH" b2="345 KV" b3="HUG-ZACH" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ZACH" b2="345 KV" b3="R1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZACH" b2="345 KV" b3="V15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZACH" b2="345 KV" b3="V25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZACH" b2="345 KV" b3="V65" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102696</SeqNum>
    <Name>138/46.Chemical.T10</Name>
    <LastEdit Timestamp="2026-01-09T15:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="138 KV" b3="AC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="46 KV" b3="AV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="46 KV" b3="AW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="138 KV" b3="T" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHEMICAL" b2="138 KV" b3="T10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="138 KV" b3="U" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102697</SeqNum>
    <Name>L138.Arboles-Marquis2</Name>
    <LastEdit Timestamp="2026-01-09T15:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ARBOLES" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ARBOLES" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ARBOLES" b2="138 KV" b3="ARB-MARQ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARQUIS2" b2="138 KV" b3="M1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102700</SeqNum>
    <Name>L230.Takoma-Harvard.23118</Name>
    <LastEdit Timestamp="2026-01-09T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVARD" b2="230 KV" b3="4A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVARD" b2="230 KV" b3="4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="1C" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARVARD" b2="230 KV" b3="HAR-TAK1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102704</SeqNum>
    <Name>L138.McDowell-McConnellsburg</Name>
    <LastEdit Timestamp="2026-01-09T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCONNEL" b2="138 KV" b3="B35" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCDOWELL" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCDOWELL" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCCONNEL" b2="138 KV" b3="MCC-MCDO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102705</SeqNum>
    <Name>L230.Takoma-Harvard.23120</Name>
    <LastEdit Timestamp="2026-01-09T15:45:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVARD" b2="230 KV" b3="2A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVARD" b2="230 KV" b3="2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="8B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="8C" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARVARD" b2="230 KV" b3="HAR-TAK2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102706</SeqNum>
    <Name>230/115.Werner.T13</Name>
    <LastEdit Timestamp="2025-11-10T10:49:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WERNER" b2="230 KV" b3="13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WERNER" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WERNER" b2="115 KV" b3="B105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WERNER" b2="115 KV" b3="B19" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102707</SeqNum>
    <Name>L345.Moro2-Roxford (Ameren)</Name>
    <LastEdit Timestamp="2026-01-12T12:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MORO2" b2="345 KV" b3="MOR-ROXF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORO2" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORO2" b2="345 KV" b3="V9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXFORD3" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXFORD3" b2="345 KV" b3="V13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102709</SeqNum>
    <Name>L230.Carroll-MtAiry.211</Name>
    <LastEdit Timestamp="2026-04-28T08:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARROLL" b2="230 KV" b3="B41" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARROLL" b2="230 KV" b3="CAR-MTA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTAIRY" b2="230 KV" b3="B12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102710</SeqNum>
    <Name>WoodchuckTrail.CrysthSP</Name>
    <LastEdit Timestamp="2026-01-12T12:26:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WDCHKTRL" b2="115 KV" b3="101672" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WDCHKTRL" b2="115 KV" b3="104772" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WDCHKTRL" b2="34.5 KV" b3="CRYSTHSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="WDCHKTRL" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WDCHKTRL" b2="34.5 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102711</SeqNum>
    <Name>L138.Beckwith-SpyRun</Name>
    <LastEdit Timestamp="2026-01-12T11:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BECKWITH" b2="138 KV" b3="BEC-SPYR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKWITH" b2="138 KV" b3="M00060" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BECKWITH" b2="138 KV" b3="M001D2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BECKWITH" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPYRUN" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102713</SeqNum>
    <Name>115/35.Oakwood.TX2 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-12T11:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="OAKWOOD" b2="115 KV" b3="H264M" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKWOOD" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKWOOD" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102715</SeqNum>
    <Name>115/13.Oakwood.TX3</Name>
    <LastEdit Timestamp="2024-10-01T15:58:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKWOOD" b2="115 KV" b3="H362" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKWOOD" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OAKWOOD" b2="13 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102723</SeqNum>
    <Name>McDowellRoad.GCOVE2SP</Name>
    <LastEdit Timestamp="2026-01-12T12:20:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="MCDOWELL" b2="34.5 KV" b3="CAP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MCDOWELL" b2="34.5 KV" b3="GCOVE2SP" />
      <ContingencyEquipment Action="X" Type="XF" b1="MCDOWELL" b2="138 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCDOWELL" b2="138 KV" b3="GSU_HCB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MCDOWELL" b2="34.5 KV" b3="REAC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102724</SeqNum>
    <Name>L138.Kewanee-Midland</Name>
    <LastEdit Timestamp="2026-01-12T11:58:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="74 KEWAN" b2="138 KV" b3="L91018" />
      <ContingencyEquipment Action="L" Type="LN" b1="910_MWF" b2="138 KV" b3="91018" />
      <ContingencyEquipment Action="U" Type="GEN" b1="910_MWF" b2="34.5 KV" b3="910MWFWF" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="910_MWF" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="910_MWF" b2="34.5 KV" b3="CAP2" />
      <ContingencyEquipment Action="X" Type="XF" b1="910_MWF" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="910_MWF" b2="138 KV" b3="TR1CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102725</SeqNum>
    <Name>L230.Thelma-OakSP</Name>
    <LastEdit Timestamp="2026-02-27T15:41:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKSP" b2="230 KV" b3="52-T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="OAKSP" b2="230 KV" b3="MPT-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="OAKSP" b2="230 KV" b3="OAK-THEL" />
      <ContingencyEquipment Action="U" Type="GEN" b1="OAKSP" b2="34.5 KV" b3="OAKSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA4" b2="230 KV" b3="213T2244" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THELMA4" b2="230 KV" b3="225T2244" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102729</SeqNum>
    <Name>McConnellsburg.GreatCove.SP</Name>
    <LastEdit Timestamp="2026-01-20T18:03:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCONNEL" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MCCONNEL" b2="34.5 KV" b3="GCOVE1SP" />
      <ContingencyEquipment Action="X" Type="XF" b1="MCCONNEL" b2="138 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102730</SeqNum>
    <Name>L138.NWTap-WLAirport-Purdue</Name>
    <LastEdit Timestamp="2026-01-20T17:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="08NW TAP" b2="138 KV" b3="NWT-WLAI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="08NW TAP" b2="138 KV" b3="PURD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PURDUE" b2="138 KV" b3="138-138" />
      <ContingencyEquipment Action="L" Type="LN" b1="PURDUE" b2="138 KV" b3="PUR-WLAI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102743</SeqNum>
    <Name>L230.McCarter-OrangeHeights.A-2306</Name>
    <LastEdit Timestamp="2026-01-22T13:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="230 KV" b3="1-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCCARTER" b2="230 KV" b3="11-12" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCCARTER" b2="230 KV" b3="MCC-ORAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORANGEHT" b2="230 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORANGEHT" b2="230 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102745</SeqNum>
    <Name>L138.Sorenson-Vanburen</Name>
    <LastEdit Timestamp="2026-01-22T13:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="138 KV" b3="M2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VANBUREN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VANBUREN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="VANBUREN" b2="138 KV" b3="VAN-SOR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102746</SeqNum>
    <Name>138/69.Vanburen.T2</Name>
    <LastEdit Timestamp="2026-01-22T13:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VANBUREN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VANBUREN" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VANBUREN" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="X" Type="XF" b1="VANBUREN" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102748</SeqNum>
    <Name>L138.Dameron-Traphill-Bolt</Name>
    <LastEdit Timestamp="2026-01-27T10:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOLT" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOLT" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAMERON" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAMERON" b2="138 KV" b3="DAM-TRAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAMERON" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOLT" b2="138 KV" b3="BOL-TRAP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRAPHILL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102749</SeqNum>
    <Name>L138.Bolt-CranyRoad</Name>
    <LastEdit Timestamp="2026-03-13T09:30:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOLT" b2="138 KV" b3="BOL-CRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOLT" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOLT" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANYROA" b2="138 KV" b3="A000A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANYROA" b2="138 KV" b3="A000A8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102755</SeqNum>
    <Name>230/138.EastDanville.T5 (Scntlz)</Name>
    <LastEdit Timestamp="2025-05-12T16:00:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EDANVILL" b2="230 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDANVILL" b2="138 KV" b3="A007L8" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="EDANVILL" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDANVILL" b2="230 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EDANVILL" b2="138 KV" b3="X5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102757</SeqNum>
    <Name>L138.Woodville-WestEndFostoria</Name>
    <LastEdit Timestamp="2026-01-27T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WEFOSTOR" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="WEFOSTOR" b2="138 KV" b3="WES-WOOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVLTE" b2="138 KV" b3="B14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODVLTE" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102758</SeqNum>
    <Name>L230.Pacific-GlobalPlaza.2234</Name>
    <LastEdit Timestamp="2026-01-27T10:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOBLPLZ" b2="230 KV" b3="223452" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLOBLPLZ" b2="230 KV" b3="GLO-PAC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOBLPLZ" b2="230 KV" b3="H12T2234" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PACIFIC" b2="230 KV" b3="21652234" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PACIFIC" b2="230 KV" b3="223432" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102759</SeqNum>
    <Name>L230.Pacific-GlobalPlaza.2231</Name>
    <LastEdit Timestamp="2026-01-27T10:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOBLPLZ" b2="230 KV" b3="223152" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLOBLPLZ" b2="230 KV" b3="GLO-PAC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOBLPLZ" b2="230 KV" b3="H12T2231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PACIFIC" b2="230 KV" b3="21702231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PACIFIC" b2="230 KV" b3="223132" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102760</SeqNum>
    <Name>L138.WestFall-Lutz</Name>
    <LastEdit Timestamp="2026-01-23T09:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LUTZ" b2="138 KV" b3="H002K8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUTZ" b2="138 KV" b3="H002L2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LUTZ" b2="138 KV" b3="LUT-WSTF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSTFALL" b2="138 KV" b3="H000A5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WSTFALL" b2="138 KV" b3="H000A8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102762</SeqNum>
    <Name>L138.BerryHill-Brosville</Name>
    <LastEdit Timestamp="2026-05-01T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERRYHIL" b2="138 KV" b3="A000H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERRYHIL" b2="138 KV" b3="A000H5" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERRYHIL" b2="138 KV" b3="BER-BROS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROSVILL" b2="138 KV" b3="A000Y5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102763</SeqNum>
    <Name>230/69.Takoma.027-12T</Name>
    <LastEdit Timestamp="2026-01-23T09:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TAKOMA" b2="230 KV" b3="027-12T" />
      <ContingencyEquipment Action="P" Type="XF" b1="TAKOMA" b2="69 KV" b3="12PAC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K11B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K9B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="8A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="8B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102765</SeqNum>
    <Name>Riley.Adams.SP</Name>
    <LastEdit Timestamp="2026-01-27T10:40:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="RILEY" b2="34.5 KV" b3="ADAMSSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RILEY" b2="115 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RILEY" b2="115 KV" b3="B30" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="RILEY" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="X" Type="XF" b1="RILEY" b2="115 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102769</SeqNum>
    <Name>DTX138.Bolt.T2</Name>
    <LastEdit Timestamp="2026-01-27T10:23:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOLT" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOLT" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOLT" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102770</SeqNum>
    <Name>L69.SafeHarbor-Manor.692+69.Manor.SouthBus</Name>
    <LastEdit Timestamp="2026-05-12T10:02:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="ENGL_1-S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="ENGL_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="FARO_16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="TRAN_3-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="SAFEHARB" b2="69 KV" b3="692" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANOR" b2="69 KV" b3="MAN-SAF4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAFEHARB" b2="13 KV" b3="TRAN692N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAFEHARB" b2="13 KV" b3="TRAN692S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102771</SeqNum>
    <Name>L69.SafeHarbor-Manor.693+69.Manor.NorthBus</Name>
    <LastEdit Timestamp="2026-05-12T10:05:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="TRAN4-CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="TRAN_3-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="TRAN_5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="WHEM_1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SAFEHARB" b2="69 KV" b3="693" />
      <ContingencyEquipment Action="L" Type="LN" b1="MANOR" b2="69 KV" b3="MAN-SAF3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAFEHARB" b2="13 KV" b3="TRAN693N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAFEHARB" b2="13 KV" b3="TRAN693S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102772</SeqNum>
    <Name>L345.Whitestown-Hortonville</Name>
    <LastEdit Timestamp="2026-01-27T10:37:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HORTONVI" b2="345 KV" b3="04-27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORTONVI" b2="345 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITESTO" b2="345 KV" b3="04-B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITESTO" b2="345 KV" b3="B2-04" />
      <ContingencyEquipment Action="L" Type="LN" b1="HORTONVI" b2="345 KV" b3="HOR-WHI1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102776</SeqNum>
    <Name>L345.Columbus-Prescott(CIN)</Name>
    <LastEdit Timestamp="2024-08-16T10:45:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLUMPSI" b2="345 KV" b3="34536" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRESCTP" b2="345 KV" b3="PRE-COL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRESCTP" b2="345 KV" b3="36-B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRESCTP" b2="345 KV" b3="B2-36" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102777</SeqNum>
    <Name>L230.LincolnPark-Discovery.2232A</Name>
    <LastEdit Timestamp="2026-05-11T11:44:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DISCOVER" b2="230 KV" b3="21072232" />
      <ContingencyEquipment Action="L" Type="LN" b1="DISCOVER" b2="230 KV" b3="DIS-LINC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DISCOVER" b2="230 KV" b3="H232" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DISCOVER" b2="13 KV" b3="LOAD 2" />
      <ContingencyEquipment Action="X" Type="XF" b1="DISCOVER" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLNP" b2="230 KV" b3="22322279" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLNP" b2="230 KV" b3="223272" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102784</SeqNum>
    <Name>L115.Gitts Run - Fairview ME</Name>
    <LastEdit Timestamp="2026-01-29T14:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GITTSRUN" b2="115 KV" b3="B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GITTSRUN" b2="115 KV" b3="B8" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GITTSRUN" b2="115 KV" b3="D15" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAIRVWME" b2="115 KV" b3="FAI-GIT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102785</SeqNum>
    <Name>DTX.GittsRun.T2</Name>
    <LastEdit Timestamp="2026-02-11T09:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GITTSRUN" b2="115 KV" b3="2 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GITTSRUN" b2="115 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GITTSRUN" b2="115 KV" b3="B7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102793</SeqNum>
    <Name>L115.Hunterstown-Orrtanna</Name>
    <LastEdit Timestamp="2026-02-26T09:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUNTERST" b2="115 KV" b3="96392" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUNTERST" b2="115 KV" b3="HUN-ORRT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORRTANNA" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORRTANNA" b2="115 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102797</SeqNum>
    <Name>L138.CranyRoad-Baileysville</Name>
    <LastEdit Timestamp="2025-09-23T13:50:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BAILEYSV" b2="138 KV" b3="BAI-CRAN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BAILEYSV" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANYROA" b2="138 KV" b3="A000A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANYROA" b2="138 KV" b3="A000A5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102798</SeqNum>
    <Name>138/69.Llanerch.TR7</Name>
    <LastEdit Timestamp="2026-02-26T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="69 KV" b3="575 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LLANERCH" b2="138 KV" b3="755 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="LLANERCH" b2="138 KV" b3="LAN 7TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102799</SeqNum>
    <Name>L345.LegHorn-Oreana.1 [ILL_EQ]</Name>
    <LastEdit Timestamp="2024-09-06T14:02:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGH" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGH" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEGH" b2="345 KV" b3="LEG-OREA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OREANA" b2="345 KV" b3="V7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OREANA" b2="345 KV" b3="V9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102800</SeqNum>
    <Name>345/138.Rising.TR2 (AMRN)</Name>
    <LastEdit Timestamp="2026-02-27T15:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="RISING" b2="345 KV" b3="45TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="138 KV" b3="H11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="345 KV" b3="V31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RISING" b2="345 KV" b3="V35" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102805</SeqNum>
    <Name>L138.HaumesserRd-H452-Waterman-Creg.11323</Name>
    <LastEdit Timestamp="2026-04-21T09:46:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="113 WATE" b2="138 KV" b3="11323 Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="113 WATE" b2="138 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="113 WATE" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="189_CREG" b2="138 KV" b3="CRE-WATE" />
      <ContingencyEquipment Action="L" Type="LN" b1="113 WATE" b2="138 KV" b3="11323 2" />
      <ContingencyEquipment Action="L" Type="LN" b1="375 W DE" b2="138 KV" b3="11323 4" />
      <ContingencyEquipment Action="S" Type="SD" b1="11323" b2="138 KV" b3="11323 5" />
      <ContingencyEquipment Action="L" Type="LN" b1="H452" b2="138 KV" b3="H45-1132" />
      <ContingencyEquipment Action="OP" Type="CB" b1="189_CREG" b2="138 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="189_CREG" b2="138 KV" b3="4-5" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="375 W DE" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="375 W DE" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="L" Type="LN" b1="94 HAURD" b2="138 KV" b3="11323" />
      <ContingencyEquipment Action="OP" Type="CB" b1="94 HAURD" b2="138 KV" b3="L11323CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H452" b2="138 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="H452" b2="138 KV" b3="BT1-2 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102809</SeqNum>
    <Name>L138.BlackRiver-Woodings</Name>
    <LastEdit Timestamp="2026-03-02T17:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLACKRIV" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLACKRIV" b2="138 KV" b3="BLA-WOOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODINGS" b2="138 KV" b3="CB-M1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODINGS" b2="138 KV" b3="CB-M2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102811</SeqNum>
    <Name>L138.Beaver-Woodings</Name>
    <LastEdit Timestamp="2026-03-02T17:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAVER" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAVER" b2="138 KV" b3="BEA-WOOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODINGS" b2="138 KV" b3="CB-M1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODINGS" b2="138 KV" b3="CB-M4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102812</SeqNum>
    <Name>138/69.Woodings.T3</Name>
    <LastEdit Timestamp="2026-02-27T15:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODINGS" b2="69 KV" b3="CB-J5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODINGS" b2="138 KV" b3="CB-M2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOODINGS" b2="138 KV" b3="CB-M4" />
      <ContingencyEquipment Action="X" Type="XF" b1="WOODINGS" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102817</SeqNum>
    <Name>L345.ABBrown-Reid</Name>
    <LastEdit Timestamp="2026-04-29T14:16:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ABBROWN" b2="345 KV" b3="1000" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ABBROWN" b2="345 KV" b3="2000" />
      <ContingencyEquipment Action="L" Type="LN" b1="ABBROWN" b2="345 KV" b3="ABB-REI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REID_BR" b2="345 KV" b3="222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REID_BR" b2="345 KV" b3="226" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102819</SeqNum>
    <Name>L138.Ontario-Cairns (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-25T14:07:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CAIRNS" b2="138 KV" b3="A617" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAIRNS" b2="138 KV" b3="CAI-ONT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONTARIOE" b2="138 KV" b3="B112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONTARIOE" b2="138 KV" b3="B113" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102820</SeqNum>
    <Name>L138.Cairns-ArmcoSteel-Longview (Sctnlz)</Name>
    <LastEdit Timestamp="2025-08-25T14:08:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="02ARMCO" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LONGVIOE" b2="138 KV" b3="LON-02A1" />
      <ContingencyEquipment Action="L" Type="LN" b1="02ARMCO" b2="138 KV" b3="02A-CAI" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CAIRNS" b2="138 KV" b3="A616" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LONGVIOE" b2="138 KV" b3="A111" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGVIOE" b2="138 KV" b3="B32" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102825</SeqNum>
    <Name>230/115.Cloud.T2</Name>
    <LastEdit Timestamp="2026-03-16T14:09:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="H222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="115 KV" b3="L222" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOUD" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102826</SeqNum>
    <Name>DTX230.Cloud.LD2V25</Name>
    <LastEdit Timestamp="2026-02-11T06:50:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="222922-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="232922-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="H222" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOUD" b2="230 KV" b3="LD2V25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="T472" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102827</SeqNum>
    <Name>DTX230.Cloud.LD1U25</Name>
    <LastEdit Timestamp="2026-02-11T06:50:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOUD" b2="230 KV" b3="LD1U25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="T472" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="T672" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102829</SeqNum>
    <Name>L138.MilesAve-WCanton</Name>
    <LastEdit Timestamp="2026-03-19T09:31:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILESAVE" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILESAVE" b2="138 KV" b3="MIL-WCA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCANTON" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102832</SeqNum>
    <Name>DTX138.Anguin.ROCKHO_F</Name>
    <LastEdit Timestamp="2026-04-09T14:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="H012A5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="H012A8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ANGUIN" b2="138 KV" b3="ROCKHO_F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102833</SeqNum>
    <Name>DTX138.Anguin.ROCKHO_E</Name>
    <LastEdit Timestamp="2026-04-09T14:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="H012B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="H012B8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ANGUIN" b2="138 KV" b3="ROCKHO_E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102838</SeqNum>
    <Name>DTX138.Babbitt.T11</Name>
    <LastEdit Timestamp="2026-04-02T09:25:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="H001Q2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BABBITT" b2="138 KV" b3="T11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102841</SeqNum>
    <Name>L345.Aster-Commodore.12266</Name>
    <LastEdit Timestamp="2026-04-07T08:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTR" b2="345 KV" b3="V5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASTR" b2="345 KV" b3="V7" />
      <ContingencyEquipment Action="L" Type="LN" b1="ASTR" b2="345 KV" b3="AST-CMDR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CMDR" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CMDR" b2="345 KV" b3="V7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102844</SeqNum>
    <Name>230/115.KittyHawk.TX3</Name>
    <LastEdit Timestamp="2026-04-09T14:18:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="230 KV" b3="H352" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="115 KV" b3="L352" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITTYHWK" b2="115 KV" b3="L3T41" />
      <ContingencyEquipment Action="X" Type="XF" b1="KITTYHWK" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102845</SeqNum>
    <Name>230/115.HarmonyVillage.TX2</Name>
    <LastEdit Timestamp="2026-04-08T09:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONYV" b2="230 KV" b3="H262" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONYV" b2="115 KV" b3="L262" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARMONYV" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102857</SeqNum>
    <Name>L138.ADM North-MtZion (ILL_EQ)</Name>
    <LastEdit Timestamp="2026-04-13T15:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ADM NORT" b2="138 KV" b3="BT1370" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ADM NORT" b2="138 KV" b3="H11" />
      <ContingencyEquipment Action="L" Type="LN" b1="ADM NORT" b2="138 KV" b3="ADM-MTZI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MT ZION" b2="138 KV" b3="H5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MT ZION" b2="138 KV" b3="H7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102860</SeqNum>
    <Name>L230.TechPark-Portugee.2198B</Name>
    <LastEdit Timestamp="2025-11-17T20:44:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUGEE" b2="230 KV" b3="219872-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUGEE" b2="230 KV" b3="219872-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TECHPARK" b2="230 KV" b3="219812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TECHPARK" b2="230 KV" b3="21982313" />
      <ContingencyEquipment Action="L" Type="LN" b1="PORTUGEE" b2="230 KV" b3="POR-TECH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102863</SeqNum>
    <Name>L500.8Anderson-Roane (TVA)</Name>
    <LastEdit Timestamp="2026-04-16T13:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="8ANDERSO" b2="500 KV" b3="5014" />
      <ContingencyEquipment Action="OP" Type="CB" b1="8ANDERSO" b2="500 KV" b3="6016" />
      <ContingencyEquipment Action="L" Type="LN" b1="8ANDERSO" b2="500 KV" b3="AND-ROA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANE" b2="500 KV" b3="5034" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANE" b2="500 KV" b3="5044" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102864</SeqNum>
    <Name>L138.Danville-Riverside</Name>
    <LastEdit Timestamp="2026-04-16T13:50:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DANVILLE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="DANVILLE" b2="138 KV" b3="DAN-RIVE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERSAP" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102867</SeqNum>
    <Name>L345.BurrOak-Hinshaw (NIPS)</Name>
    <LastEdit Timestamp="2025-08-22T08:19:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURR_OAK" b2="345 KV" b3="09-40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURR_OAK" b2="345 KV" b3="40CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURR_OAK" b2="345 KV" b3="BUR-HINS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINSHAW" b2="345 KV" b3="40N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINSHAW" b2="345 KV" b3="40S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102868</SeqNum>
    <Name>L161.BeaverChannel-Sub49 (MISO)</Name>
    <LastEdit Timestamp="2026-04-21T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BVR CH 6" b2="161 KV" b3="145" />
      <ContingencyEquipment Action="L" Type="LN" b1="BVR CH 6" b2="161 KV" b3="62084622" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SB 49  6" b2="161 KV" b3="874GCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102869</SeqNum>
    <Name>L115.HarmonyVillage-OwlTrap.1033</Name>
    <LastEdit Timestamp="2025-08-22T10:35:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARMONYV" b2="115 KV" b3="103362" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OWLTRAP" b2="115 KV" b3="10331060" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OWLTRAP" b2="115 KV" b3="103322" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARMONYV" b2="115 KV" b3="HAR-OWLT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102870</SeqNum>
    <Name>DTX.Kileville.Shire1</Name>
    <LastEdit Timestamp="2026-04-21T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KILEVILL" b2="138 KV" b3="H003B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KILEVILL" b2="138 KV" b3="H003B5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KILEVILL" b2="138 KV" b3="SHIRE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102871</SeqNum>
    <Name>DTX.Kileville.Shire2</Name>
    <LastEdit Timestamp="2026-04-23T08:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KILEVILL" b2="138 KV" b3="H003A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KILEVILL" b2="138 KV" b3="H003A5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KILEVILL" b2="138 KV" b3="SHIRE2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102872</SeqNum>
    <Name>DTX.Kileville.Shire3</Name>
    <LastEdit Timestamp="2026-04-23T08:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KILEVILL" b2="138 KV" b3="H002N2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KILEVILL" b2="138 KV" b3="H002N5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KILEVILL" b2="138 KV" b3="SHIRE3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102873</SeqNum>
    <Name>DTX.Kileville.Shire4</Name>
    <LastEdit Timestamp="2026-04-23T08:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KILEVILL" b2="138 KV" b3="H002M2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KILEVILL" b2="138 KV" b3="H002M5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KILEVILL" b2="138 KV" b3="SHIRE4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102875</SeqNum>
    <Name>138/34.Streator.TR77 </Name>
    <LastEdit Timestamp="2026-04-21T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="61 STREA" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="61 STREA" b2="34.5 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="61 STREA" b2="34.5 KV" b3="BT3-4 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="61 STREA" b2="138 KV" b3="L6102 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="61 STREA" b2="138 KV" b3="TR77 34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102876</SeqNum>
    <Name>138/34.Streator.TR78 </Name>
    <LastEdit Timestamp="2026-04-21T09:27:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="61 STREA" b2="138 KV" b3="BT2-3 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="61 STREA" b2="34.5 KV" b3="BT6-7 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="61 STREA" b2="34.5 KV" b3="BT7-8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="61 STREA" b2="138 KV" b3="L6101 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="61 STREA" b2="138 KV" b3="TR78 34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102880</SeqNum>
    <Name>L138.CreekWalker-GravelPit</Name>
    <LastEdit Timestamp="2026-04-24T08:29:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CREEKWLK" b2="138 KV" b3="M004E5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CREEKWLK" b2="138 KV" b3="M004E8" />
      <ContingencyEquipment Action="L" Type="LN" b1="CREEKWLK" b2="138 KV" b3="CRE-GRAV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GRAVLPIT" b2="138 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102881</SeqNum>
    <Name>CreekWalker.HoneySuckleSP</Name>
    <LastEdit Timestamp="2026-02-10T09:44:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CREEKWLK" b2="138 KV" b3="52-T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CREEKWLK" b2="138 KV" b3="AUXLD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CREEKWLK" b2="138 KV" b3="HONEYSSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102882</SeqNum>
    <Name>L230.LostCity-TechPark.2313A</Name>
    <LastEdit Timestamp="2025-05-20T09:34:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOSTCIT2" b2="230 KV" b3="22822313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOSTCIT2" b2="230 KV" b3="231362" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOSTCIT2" b2="230 KV" b3="LOS-TECH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TECHPARK" b2="230 KV" b3="21982313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TECHPARK" b2="230 KV" b3="231312" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102883</SeqNum>
    <Name>DTX345.Cosgray.CMH0911</Name>
    <LastEdit Timestamp="2026-04-24T08:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COSGRAY" b2="345 KV" b3="CMH0911" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COSGRAY" b2="345 KV" b3="H001X5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COSGRAY" b2="345 KV" b3="H001X8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102884</SeqNum>
    <Name>DTX345.Cosgray.CMH0912</Name>
    <LastEdit Timestamp="2026-04-24T08:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COSGRAY" b2="345 KV" b3="CMH0912" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COSGRAY" b2="345 KV" b3="H001W2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COSGRAY" b2="345 KV" b3="H001X2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102885</SeqNum>
    <Name>DTX345.Cosgray.CMH0913</Name>
    <LastEdit Timestamp="2026-04-24T08:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COSGRAY" b2="345 KV" b3="CMH0913" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COSGRAY" b2="345 KV" b3="H001W2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COSGRAY" b2="345 KV" b3="H001W5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102886</SeqNum>
    <Name>DTX345.Cosgray.CMH0914</Name>
    <LastEdit Timestamp="2026-04-24T08:28:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COSGRAY" b2="345 KV" b3="CMH0914" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COSGRAY" b2="345 KV" b3="H001W8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COSGRAY" b2="345 KV" b3="H001X8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102887</SeqNum>
    <Name>L345.Losantville-RiverStartIII</Name>
    <LastEdit Timestamp="2026-04-24T08:42:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOSANTVL" b2="345 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOSANTVL" b2="345 KV" b3="D2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOSANTVL" b2="345 KV" b3="LOS-RIV3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERST3" b2="345 KV" b3="52U3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERST3" b2="345 KV" b3="52U5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102888</SeqNum>
    <Name>RiverStartIII.River2SP</Name>
    <LastEdit Timestamp="2026-02-10T09:44:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERST3" b2="345 KV" b3="52U4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RIVERST3" b2="34.5 KV" b3="RIVER2SP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERST3" b2="34.5 KV" b3="SST_2" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIVERST3" b2="345 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102889</SeqNum>
    <Name>RiverStartIII.River3SP</Name>
    <LastEdit Timestamp="2026-02-10T09:44:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERST3" b2="345 KV" b3="52U3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="RIVERST3" b2="34.5 KV" b3="RIVER3SP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERST3" b2="34.5 KV" b3="SST_1" />
      <ContingencyEquipment Action="X" Type="XF" b1="RIVERST3" b2="345 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102890</SeqNum>
    <Name>OwlTrap.Carver.SP</Name>
    <LastEdit Timestamp="2026-04-27T10:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="OWLTRAP" b2="34.5 KV" b3="CARVERSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="OWLTRAP" b2="115 KV" b3="MPT-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OWLTRAP" b2="115 KV" b3="T1-CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102891</SeqNum>
    <Name>L138.CherryCreek-RaleighCountyAirport</Name>
    <LastEdit Timestamp="2026-05-20T17:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHERRYCR" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RALEIGHC" b2="138 KV" b3="A002V2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHERRYCR" b2="138 KV" b3="CHE-RALE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102892</SeqNum>
    <Name>L69.Narrows-Stevensville</Name>
    <LastEdit Timestamp="2026-05-11T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NARROWS" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NARROWS" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STVNSVIL" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="L" Type="LN" b1="NARROWS" b2="69 KV" b3="NAR-STV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102894</SeqNum>
    <Name>161/138.PowellCounty.XF156</Name>
    <LastEdit Timestamp="2026-04-27T09:56:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POWELLCO" b2="161 KV" b3="1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POWELLCO" b2="138 KV" b3="CB828" />
      <ContingencyEquipment Action="X" Type="XF" b1="POWELLCO" b2="161 KV" b3="XF156" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102895</SeqNum>
    <Name>L69.Grasonville-Narrows</Name>
    <LastEdit Timestamp="2026-05-11T09:57:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRSNVILL" b2="69 KV" b3="7660" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRSNVILL" b2="69 KV" b3="GRS-NAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NARROWS" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NARROWS" b2="69 KV" b3="66" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102896</SeqNum>
    <Name>L230.WashingtonAve-CookRoad-Harvey</Name>
    <LastEdit Timestamp="2026-04-29T12:36:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COOKRD" b2="230 KV" b3="COO-HARV" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOKRD" b2="230 KV" b3="COO-WASH" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COOKRD" b2="230 KV" b3="LOADTRAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COOKRD" b2="230 KV" b3="T2_LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COOKRD" b2="230 KV" b3="T4_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVEY" b2="230 KV" b3="2-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVEY" b2="230 KV" b3="7-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WASHAVE" b2="230 KV" b3="1-2CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WASHAVE" b2="230 KV" b3="T-10LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102897</SeqNum>
    <Name>138/69.Lick.TR5</Name>
    <LastEdit Timestamp="2024-08-15T16:39:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LICK" b2="138 KV" b3="102" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICK" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICK" b2="138 KV" b3="BB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LICK" b2="138 KV" b3="CAP4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LICK" b2="138 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102898</SeqNum>
    <Name>115/35.VirginiaBeach.TX3 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-30T13:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="VABEACH" b2="115 KV" b3="H374M" />
      <ContingencyEquipment Action="X" Type="XF" b1="VABEACH" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VABEACH" b2="13 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102899</SeqNum>
    <Name>115/35.VirginiaBeach.TX3 (Sctnlz F)</Name>
    <LastEdit Timestamp="2026-04-30T13:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="115 KV" b3="7872" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="115 KV" b3="H172" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="VABEACH" b2="115 KV" b3="H374M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="115 KV" b3="L572" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="115 KV" b3="SC572" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="115 KV" b3="T122" />
      <ContingencyEquipment Action="X" Type="XF" b1="VABEACH" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VABEACH" b2="13 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102900</SeqNum>
    <Name>115/35.VirginiaBeach.TX4 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-30T13:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="VABEACH" b2="115 KV" b3="H474M" />
      <ContingencyEquipment Action="X" Type="XF" b1="VABEACH" b2="115 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VABEACH" b2="13 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102901</SeqNum>
    <Name>115/35.VirginiaBeach.TX4 (Sctnlz F)</Name>
    <LastEdit Timestamp="2026-04-30T13:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="115 KV" b3="2772" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="VABEACH" b2="115 KV" b3="H274M" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="VABEACH" b2="115 KV" b3="H474M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="115 KV" b3="L672" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VABEACH" b2="115 KV" b3="T122" />
      <ContingencyEquipment Action="X" Type="XF" b1="VABEACH" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VABEACH" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="VABEACH" b2="115 KV" b3="TX4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VABEACH" b2="13 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102903</SeqNum>
    <Name>230/35.JeffersonStreet.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-04-29T12:24:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="JEFFRSON" b2="230 KV" b3="H324M" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="JEFFRSON" b2="230 KV" b3="SC5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFRSON" b2="230 KV" b3="SC522" />
      <ContingencyEquipment Action="X" Type="XF" b1="JEFFRSON" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JEFFRSON" b2="35 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102904</SeqNum>
    <Name>L138.BuffaloMarsh-Meadowbrook</Name>
    <LastEdit Timestamp="2026-05-04T15:12:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFALOM" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUFFALOM" b2="138 KV" b3="B30" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUFFALOM" b2="138 KV" b3="BUF-MEAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWBR" b2="138 KV" b3="MD5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102905</SeqNum>
    <Name>L345.GunnRoad-BokesCreek</Name>
    <LastEdit Timestamp="2026-04-08T09:56:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOKESCR" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOKESCR" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOKESCR" b2="345 KV" b3="BOK-GUNN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUNNROAD" b2="345 KV" b3="H025P2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUNNROAD" b2="345 KV" b3="N1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102906</SeqNum>
    <Name>L345.Marysville-BokesCreek</Name>
    <LastEdit Timestamp="2026-05-05T09:55:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOKESCR" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOKESCR" b2="345 KV" b3="BOK-MARY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOKESCR" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="345 KV" b3="J1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="345 KV" b3="J2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102907</SeqNum>
    <Name>BokesCreek.UnionSP</Name>
    <LastEdit Timestamp="2026-05-12T09:23:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOKESCR" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOKESCR" b2="34.5 KV" b3="AUXLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOKESCR" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="X" Type="XF" b1="BOKESCR" b2="345 KV" b3="MPT1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BOKESCR" b2="345 KV" b3="MPT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BOKESCR" b2="34.5 KV" b3="UNIONSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102911</SeqNum>
    <Name>L345.Bisn-Turn (AMIL)</Name>
    <LastEdit Timestamp="2026-05-06T11:54:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BISN" b2="345 KV" b3="BIS-TURN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISN" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISN" b2="345 KV" b3="V7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURN" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TURN" b2="345 KV" b3="V3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102919</SeqNum>
    <Name>DTX69.Narrows.LOAD1</Name>
    <LastEdit Timestamp="2026-05-08T10:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NARROWS" b2="69 KV" b3="65" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NARROWS" b2="69 KV" b3="66" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NARROWS" b2="69 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102920</SeqNum>
    <Name>DTX69.Narrows.LOAD2</Name>
    <LastEdit Timestamp="2026-05-08T10:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NARROWS" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NARROWS" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NARROWS" b2="69 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102923</SeqNum>
    <Name>230/69.Takoma.027-8T</Name>
    <LastEdit Timestamp="2024-07-01T22:37:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TAKOMA" b2="230 KV" b3="027-8T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="6B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="6C" />
      <ContingencyEquipment Action="P" Type="XF" b1="TAKOMA" b2="69 KV" b3="8PAC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102924</SeqNum>
    <Name>230/34.Takoma.027-10T</Name>
    <LastEdit Timestamp="2024-06-24T21:04:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TAKOMA" b2="230 KV" b3="027-10T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="34 KV" b3="10TS3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="34 KV" b3="10TS4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="2C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102928</SeqNum>
    <Name>DTX69.Ontario.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-07-17T08:50:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ONTARIO" b2="69 KV" b3="LOAD3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ONTARIO" b2="69 KV" b3="W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONTARIO" b2="69 KV" b3="WIND" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ONTARIO" b2="69 KV" b3="WINDPWR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102929</SeqNum>
    <Name>DTX69.Ontario.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-07-17T08:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="ONTARIO" b2="69 KV" b3="GEN_DUM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ONTARIO" b2="69 KV" b3="LOAD4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ONTARIO" b2="69 KV" b3="MIDTWNGT" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ONTARIO" b2="69 KV" b3="V" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102930</SeqNum>
    <Name>DTX138.Riverville.T2</Name>
    <LastEdit Timestamp="2026-05-14T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIL" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERVIL" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102931</SeqNum>
    <Name>DTX138.Riverville.T1</Name>
    <LastEdit Timestamp="2026-05-14T09:32:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIL" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERVIL" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102941</SeqNum>
    <Name>L230.Klecknersville-MartinsCreek</Name>
    <LastEdit Timestamp="2026-05-22T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KLECKNER" b2="230 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KLECKNER" b2="230 KV" b3="B6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="GEN4KLEC" />
      <ContingencyEquipment Action="L" Type="LN" b1="KLECKNER" b2="230 KV" b3="KLE-MART" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="KLEC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102942</SeqNum>
    <Name>L69.Kennel-Miller.2</Name>
    <LastEdit Timestamp="2026-06-03T14:38:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNEL" b2="69 KV" b3="CB748" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNEL" b2="69 KV" b3="CB751" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILLER1" b2="69 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENNEL" b2="69 KV" b3="KEN-MIL2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MILLER1" b2="69 KV" b3="SW618" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102943</SeqNum>
    <Name>L138.Kline-Twinbranch</Name>
    <LastEdit Timestamp="2026-05-21T09:46:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KLINE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="KLINE" b2="138 KV" b3="KLI-TWI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KLINE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KLINE" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KLINE" b2="138 KV" b3="TWINB1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="V" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="V1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102944</SeqNum>
    <Name>L138.Gilboa-JonesBranch-Belva-Carbondale</Name>
    <LastEdit Timestamp="2026-05-21T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELVAAEP" b2="138 KV" b3="BEL-CAR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELVAAEP" b2="138 KV" b3="T1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARBOND2" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="L" Type="LN" b1="GILB APS" b2="138 KV" b3="GIL-JON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILB APS" b2="138 KV" b3="JONESTAP" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELVAAEP" b2="138 KV" b3="BEL-JON" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JONESTAP" b2="138 KV" b3="JONES" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102945</SeqNum>
    <Name>138/69/46.Carbondale.T1</Name>
    <LastEdit Timestamp="2026-05-19T09:38:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CARBOND2" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARBOND2" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="CARBOND2" b2="46 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARBOND2" b2="46 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARBOND2" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARBOND2" b2="138 KV" b3="L" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102946</SeqNum>
    <Name>L138.Badger-JugStreet</Name>
    <LastEdit Timestamp="2026-05-20T17:39:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BADGRAEP" b2="138 KV" b3="H007K5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BADGRAEP" b2="138 KV" b3="H007K8" />
      <ContingencyEquipment Action="L" Type="LN" b1="BADGRAEP" b2="138 KV" b3="BAD-JUGS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="138 KV" b3="N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102947</SeqNum>
    <Name>L345.Commodore-Jord.(ILL_EQ)</Name>
    <LastEdit Timestamp="2026-05-22T09:37:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CMDR" b2="345 KV" b3="CMD-JORD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CMDR" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CMDR" b2="345 KV" b3="V9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JORD" b2="345 KV" b3="V23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JORD" b2="345 KV" b3="V25" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102949</SeqNum>
    <Name>L230.Rancocas-Cinnaminson.K-2342</Name>
    <LastEdit Timestamp="2026-06-01T09:40:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CINNAMIN" b2="230 KV" b3="1-2CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="CINNAMIN" b2="230 KV" b3="CIN-RANC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RANCOCAS" b2="230 KV" b3="1-2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RANCOCAS" b2="230 KV" b3="T-10CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102952</SeqNum>
    <Name>DTX69.CapeMay.T2</Name>
    <LastEdit Timestamp="2026-06-02T11:04:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPEMAY" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPEMAY" b2="69 KV" b3="G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAPEMAY" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102953</SeqNum>
    <Name>DTX69.CapeMay.T3</Name>
    <LastEdit Timestamp="2026-06-02T11:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPEMAY" b2="69 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAPEMAY" b2="69 KV" b3="F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAPEMAY" b2="69 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102954</SeqNum>
    <Name>L138.JoshuaFalls-Riverville</Name>
    <LastEdit Timestamp="2024-05-06T14:59:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOSHUAF2" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOSHUAF2" b2="138 KV" b3="G2" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOSHUAF2" b2="138 KV" b3="JOS-RIVE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIL" b2="138 KV" b3="A2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102955</SeqNum>
    <Name>DTX138.Riverville.T3</Name>
    <LastEdit Timestamp="2024-05-06T15:07:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIL" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIL" b2="138 KV" b3="AA_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIL" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIVERVIL" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102956</SeqNum>
    <Name>138/46.Chemical.T6</Name>
    <LastEdit Timestamp="2024-11-19T17:32:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CHEMICAL" b2="138 KV" b3=".  6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="46 KV" b3="AJ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="46 KV" b3="AK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHEMICAL" b2="138 KV" b3="XT6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102958</SeqNum>
    <Name>L138.WolfLake-Sheffield</Name>
    <LastEdit Timestamp="2024-05-09T14:56:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="17WOLFLK" b2="138 KV" b3="BUST" />
      <ContingencyEquipment Action="X" Type="XF" b1="17WOLFLK" b2="138 KV" b3="X2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17WOLFLK" b2="34 KV" b3="X2DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="138 KV" b3="7793" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHEFFILD" b2="138 KV" b3="SHE-17W1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="138 KV" b3="X293" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102964</SeqNum>
    <Name>DTX138.Cyprus.ChillyWC</Name>
    <LastEdit Timestamp="2024-05-17T09:41:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CYPRUS" b2="138 KV" b3="CHILLYWC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000E5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000E8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102968</SeqNum>
    <Name>DTX69.Millsboro.T1</Name>
    <LastEdit Timestamp="2024-05-13T12:57:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILSBORO" b2="69 KV" b3="7420" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILSBORO" b2="69 KV" b3="7440" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILSBORO" b2="69 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102969</SeqNum>
    <Name>DTX69.Millsboro.T2</Name>
    <LastEdit Timestamp="2024-05-13T12:59:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILSBORO" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILSBORO" b2="69 KV" b3="7410" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILSBORO" b2="69 KV" b3="LOADT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102971</SeqNum>
    <Name>L230.Finneywood-Briery-Farmville.235</Name>
    <LastEdit Timestamp="2025-12-05T14:19:03" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRIERY" b2="230 KV" b3="235B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIERY" b2="230 KV" b3="BRI-FINN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRIERY" b2="230 KV" b3="LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="230 KV" b3="235T298" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="230 KV" b3="H332" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="230 KV" b3="H432" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINNEYWD" b2="230 KV" b3="23572" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINNEYWD" b2="230 KV" b3="UT235" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102972</SeqNum>
    <Name>DTX138.Cyprus.ChillyWD</Name>
    <LastEdit Timestamp="2024-05-17T12:03:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CYPRUS" b2="138 KV" b3="CHILLYWD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000C5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000C8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102977</SeqNum>
    <Name>L345.Madison-Greene</Name>
    <LastEdit Timestamp="2024-05-21T14:08:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="345 KV" b3="DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENE" b2="345 KV" b3="EE" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENE" b2="345 KV" b3="GRE-MADI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON2" b2="345 KV" b3="JM-CC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON2" b2="345 KV" b3="JM-DD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102979</SeqNum>
    <Name>345/69.Madison.BK-N</Name>
    <LastEdit Timestamp="2024-05-29T10:13:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MADISON2" b2="345 KV" b3="BK-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON2" b2="69 KV" b3="JM-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON2" b2="345 KV" b3="JM-AA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON2" b2="345 KV" b3="JM-DD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102980</SeqNum>
    <Name>DTX.OysterCreek.BK11</Name>
    <LastEdit Timestamp="2024-05-21T14:15:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OYSTERCR" b2="230 KV" b3="B101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OYSTERCR" b2="230 KV" b3="B98" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OYSTERCR" b2="230 KV" b3="T11LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102981</SeqNum>
    <Name>DTX230.Cloud.LD4Z25</Name>
    <LastEdit Timestamp="2026-02-11T06:50:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOUD" b2="230 KV" b3="LD4Z25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="T352" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="T562" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102982</SeqNum>
    <Name>L230.Milton-Sunbury.2</Name>
    <LastEdit Timestamp="2024-05-21T15:06:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MILTON" b2="230 KV" b3="MIL-SUN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON" b2="230 KV" b3="MON1SUN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON" b2="230 KV" b3="SUNB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="ELDRMIL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="230 KV" b3="MILT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102983</SeqNum>
    <Name>115/46.Cambria.BK1</Name>
    <LastEdit Timestamp="2024-05-21T15:11:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIA" b2="115 KV" b3="B31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMBRIA" b2="115 KV" b3="B34" />
      <ContingencyEquipment Action="X" Type="XF" b1="CAMBRIA" b2="115 KV" b3="BK_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102987</SeqNum>
    <Name>DTX138.126State.TR75-12</Name>
    <LastEdit Timestamp="2024-05-23T14:53:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="126 STAT" b2="138 KV" b3="BT4-5_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="126 STAT" b2="138 KV" b3="BT5-6_CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="126 STAT" b2="138 KV" b3="TR75 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102990</SeqNum>
    <Name>RAS.L230.Finneywood-Briery-Farmville.235+Clover.U2</Name>
    <LastEdit Timestamp="2026-02-11T06:42:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRIERY" b2="230 KV" b3="235B" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIERY" b2="230 KV" b3="BRI-FINN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRIERY" b2="230 KV" b3="LOAD" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="25 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G2TL9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOVER" b2="7 KV" b3="SS2LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="230 KV" b3="235T298" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="230 KV" b3="H332" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="230 KV" b3="H432" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINNEYWD" b2="230 KV" b3="23572" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINNEYWD" b2="230 KV" b3="UT235" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102991</SeqNum>
    <Name>L230.Cloud-Easters.2229</Name>
    <LastEdit Timestamp="2024-05-28T15:40:25" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="222922-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="222922-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="222932" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOUD" b2="230 KV" b3="CLD-EAST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="VT2229" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102992</SeqNum>
    <Name>RAS.L230.Cloud-Easters.2229 + Clover.U2</Name>
    <LastEdit Timestamp="2026-02-11T06:43:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="222922-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="222922-4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="25 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G2TL9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOVER" b2="7 KV" b3="SS2LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="222932" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLOUD" b2="230 KV" b3="CLD-EAST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTERS" b2="230 KV" b3="VT2229" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102993</SeqNum>
    <Name>L230.MtVernon-Waterfront.23143</Name>
    <LastEdit Timestamp="2024-05-28T17:04:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MTVERPEP" b2="230 KV" b3="4A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTVERPEP" b2="230 KV" b3="4B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="1BCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="1CCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTVERPEP" b2="230 KV" b3="MTV-WAT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102994</SeqNum>
    <Name>Atlanta.Buckey.SP</Name>
    <LastEdit Timestamp="2024-05-28T17:17:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLNTA" b2="69 KV" b3="BUCKEYCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ATLNTA" b2="69 KV" b3="BUCKEYSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>102995</SeqNum>
    <Name>Atlanta.Pickaw.SP</Name>
    <LastEdit Timestamp="2024-05-28T17:18:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ATLNTA" b2="69 KV" b3="PICKAWCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ATLNTA" b2="69 KV" b3="PICKAWSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103007</SeqNum>
    <Name>138/115.Garrett.TRAN2</Name>
    <LastEdit Timestamp="2024-08-20T11:27:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GARRETT" b2="115 KV" b3="CS3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARRETT" b2="138 KV" b3="T2 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GARRETT" b2="138 KV" b3="TRAN  2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103008</SeqNum>
    <Name>DTX138.Anguin.Liberty3</Name>
    <LastEdit Timestamp="2024-06-04T12:46:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="52T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ANGUIN" b2="138 KV" b3="LIBERTY3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103009</SeqNum>
    <Name>DTX138.Anguin.Liberty2</Name>
    <LastEdit Timestamp="2024-06-04T13:26:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="52T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="H009H2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ANGUIN" b2="138 KV" b3="LIBERTY2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103010</SeqNum>
    <Name>DTX138.Anguin.Liberty1</Name>
    <LastEdit Timestamp="2024-06-04T13:27:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="52T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="H009J2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ANGUIN" b2="138 KV" b3="LIBERTY1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103012</SeqNum>
    <Name>L230.Racefield-Brambleton.2227</Name>
    <LastEdit Timestamp="2024-06-07T09:23:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="206T2227" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="222702" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRAMBLET" b2="230 KV" b3="BRA-RACE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RACEFIEL" b2="230 KV" b3="222792-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RACEFIEL" b2="230 KV" b3="222792-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103013</SeqNum>
    <Name>DTX.Racefield.Load1</Name>
    <LastEdit Timestamp="2024-06-07T08:53:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RACEFIEL" b2="230 KV" b3="209492-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RACEFIEL" b2="230 KV" b3="222792-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RACEFIEL" b2="230 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103014</SeqNum>
    <Name>DTX.Racefield.Load2</Name>
    <LastEdit Timestamp="2024-06-07T08:53:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RACEFIEL" b2="230 KV" b3="209492-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RACEFIEL" b2="230 KV" b3="222792-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RACEFIEL" b2="230 KV" b3="LOAD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103016</SeqNum>
    <Name>L230.Pembroke-Chowan-Edenton-Mackeys.2131</Name>
    <LastEdit Timestamp="2024-06-10T09:14:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHOWAN" b2="230 KV" b3="CHO-PEMB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHOWAN" b2="230 KV" b3="H112" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHOWAN" b2="230 KV" b3="TX_1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHOWAN" b2="35 KV" b3="TX_1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHOWAN" b2="230 KV" b3="2131B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDENTON" b2="230 KV" b3="H152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EDENTON" b2="230 KV" b3="H252" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDENTON" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EDENTON" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDENTON" b2="230 KV" b3="TX_1" />
      <ContingencyEquipment Action="X" Type="XF" b1="EDENTON" b2="230 KV" b3="TX_2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EDENTON" b2="230 KV" b3="2131A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACKEYS" b2="230 KV" b3="H1T2131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACKEYS" b2="230 KV" b3="H2T2131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEMBROKE" b2="230 KV" b3="20922131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEMBROKE" b2="230 KV" b3="21312293" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103017</SeqNum>
    <Name>L138.Franklin-Sidney</Name>
    <LastEdit Timestamp="2024-06-10T09:16:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09SIDNEY" b2="138 KV" b3="BA-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09SIDNEY" b2="138 KV" b3="BA-C" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKLI5" b2="138 KV" b3="FRA-SIDN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLI5" b2="138 KV" b3="BN-B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLI5" b2="138 KV" b3="BN-C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103018</SeqNum>
    <Name>L138.Amsterdam-Franklin + 138/69.Amsterdam.TR7</Name>
    <LastEdit Timestamp="2026-03-05T15:00:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="09AMSTRD" b2="69 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="09AMSTRD" b2="69 KV" b3="8" />
      <ContingencyEquipment Action="L" Type="LN" b1="09AMSTRD" b2="138 KV" b3="AMS-FRAN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="09AMSTRD" b2="69 KV" b3="BK-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="09AMSTRD" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLI5" b2="138 KV" b3="BN-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLI5" b2="138 KV" b3="BN-D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103019</SeqNum>
    <Name>L230.Alton-Hendrick.2217</Name>
    <LastEdit Timestamp="2024-08-20T07:46:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTON" b2="230 KV" b3="221752" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTON" b2="230 KV" b3="296T2217" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HENDRICK" b2="230 KV" b3="22172241" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HENDRICK" b2="230 KV" b3="221762" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALTON" b2="230 KV" b3="ALT-HEND" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103020</SeqNum>
    <Name>L230.AltonSP</Name>
    <LastEdit Timestamp="2024-06-10T09:24:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTON" b2="230 KV" b3="221752" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTON" b2="230 KV" b3="29652" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ALTON" b2="34.5 KV" b3="ALTPOSSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="ALTON" b2="230 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103021</SeqNum>
    <Name>Inez.MartinCountySolar</Name>
    <LastEdit Timestamp="2024-06-11T12:22:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INEZ" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INEZ" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="X" Type="XF" b1="INEZ" b2="138 KV" b3="GSU1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="INEZ" b2="34.5 KV" b3="MARTC1SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="INEZ" b2="34.5 KV" b3="MARTC2SP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103022</SeqNum>
    <Name>230/114.Cloud.TX1</Name>
    <LastEdit Timestamp="2024-06-11T12:55:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="H122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="115 KV" b3="L122" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLOUD" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103023</SeqNum>
    <Name>230/34.Takmoa.5T</Name>
    <LastEdit Timestamp="2024-06-13T08:42:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TAKOMA" b2="230 KV" b3="027-5T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="34 KV" b3="5TS1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="34 KV" b3="5TS3B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103024</SeqNum>
    <Name>230/69.Takoma.7T</Name>
    <LastEdit Timestamp="2024-08-11T22:03:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="TAKOMA" b2="230 KV" b3="027-7T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="5B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="230 KV" b3="5C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K10B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAKOMA" b2="69 KV" b3="69K12B" />
      <ContingencyEquipment Action="P" Type="XF" b1="TAKOMA" b2="69 KV" b3="7PAC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103025</SeqNum>
    <Name>L345.Carlson-Reynold</Name>
    <LastEdit Timestamp="2026-05-08T11:47:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLSON" b2="345 KV" b3="46N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLSON" b2="345 KV" b3="46S" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARLSON" b2="345 KV" b3="CAR-REYN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="39-46" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="46" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103026</SeqNum>
    <Name>L345.Carlson-Cavalry</Name>
    <LastEdit Timestamp="2024-06-17T18:08:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLSON" b2="345 KV" b3="47N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLSON" b2="345 KV" b3="47S" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARLSON" b2="345 KV" b3="CAR-CAVA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAVALRY" b2="345 KV" b3="47" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103027</SeqNum>
    <Name>L345.BurrOak-Carlson</Name>
    <LastEdit Timestamp="2024-06-17T18:26:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BURR_OAK" b2="345 KV" b3="28" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BURR_OAK" b2="345 KV" b3="28-29" />
      <ContingencyEquipment Action="L" Type="LN" b1="CARLSON" b2="345 KV" b3="CAR-BURR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLSON" b2="345 KV" b3="28N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARLSON" b2="345 KV" b3="28S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103029</SeqNum>
    <Name>L230.MartinsCreek-MorrisPark-Gilbert.P-2016 w/LX</Name>
    <LastEdit Timestamp="2024-09-06T14:57:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBERT" b2="230 KV" b3="B57" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GILBERT" b2="230 KV" b3="B72" />
      <ContingencyEquipment Action="L" Type="LN" b1="GILBERT" b2="230 KV" b3="GIL-MRP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="GBRT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="230 KV" b3="GBRTMONR" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARTINSC" b2="230 KV" b3="MAR-MRP" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MORRISPA" b2="35 KV" b3="BK 1" />
      <ContingencyEquipment Action="LT" Type="LOAD" b1="MORRISPA" b2="35 KV" b3="BK 2" />
      <ContingencyEquipment Action="X" Type="XF" b1="MORRISPA" b2="230 KV" b3="BK2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MORRISPA" b2="230 KV" b3="BK2 DS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103030</SeqNum>
    <Name>L230.Sandlot-CannonBranch.2225</Name>
    <LastEdit Timestamp="2024-06-25T12:52:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CANNONBR" b2="230 KV" b3="21482225" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANNONBR" b2="230 KV" b3="222522" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDLOT" b2="230 KV" b3="22252230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDLOT" b2="230 KV" b3="222542" />
      <ContingencyEquipment Action="L" Type="LN" b1="CANNONBR" b2="230 KV" b3="CAN-SAN1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103036</SeqNum>
    <Name>138/69.Skaggs.T1810</Name>
    <LastEdit Timestamp="2024-06-28T14:28:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SKAGGS" b2="69 KV" b3="E35-638" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SKAGGS" b2="138 KV" b3="E35-808" />
      <ContingencyEquipment Action="X" Type="XF" b1="SKAGGS" b2="138 KV" b3="XF1810" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103037</SeqNum>
    <Name>161/69.Denny.T186</Name>
    <LastEdit Timestamp="2025-12-17T14:09:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNY" b2="161 KV" b3="S27-1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DENNY" b2="69 KV" b3="S27-608" />
      <ContingencyEquipment Action="X" Type="XF" b1="DENNY" b2="161 KV" b3="XF186" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103038</SeqNum>
    <Name>161/69.CaseyCo.XF181</Name>
    <LastEdit Timestamp="2024-06-28T14:41:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CASEYCO" b2="161 KV" b3="CB1008" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CASEYCO" b2="69 KV" b3="CB608" />
      <ContingencyEquipment Action="X" Type="XF" b1="CASEYCO" b2="161 KV" b3="XF181" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103040</SeqNum>
    <Name>L345.Hills-SubT-Louisa(MEC)</Name>
    <LastEdit Timestamp="2024-07-03T12:21:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HILLS  6" b2="345 KV" b3="62208622" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLS  6" b2="345 KV" b3="914" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILLS  6" b2="345 KV" b3="924" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="HILLS  6" b2="345 KV" b3="REACT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOUISA 6" b2="345 KV" b3="62207622" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISA 6" b2="345 KV" b3="93924" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOUISA 6" b2="345 KV" b3="93964" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUB T  6" b2="345 KV" b3="944" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103042</SeqNum>
    <Name>L138.Boxwood-Amherst-Riverville</Name>
    <LastEdit Timestamp="2025-02-18T12:37:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMHERST" b2="138 KV" b3="AMH-RIVE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMHERST" b2="138 KV" b3="XT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMHERST" b2="138 KV" b3="AMH-BOXW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOXWOOD" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOXWOOD" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIL" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIL" b2="138 KV" b3="B2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103043</SeqNum>
    <Name>DTX138.Boxwood.T2</Name>
    <LastEdit Timestamp="2024-07-09T12:48:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOXWOOD" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOXWOOD" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOXWOOD" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103044</SeqNum>
    <Name>138/69.Brosville.TR1</Name>
    <LastEdit Timestamp="2026-03-05T14:55:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROSVILL" b2="138 KV" b3="A000Y5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROSVILL" b2="138 KV" b3="A000Y8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BROSVILL" b2="69 KV" b3="CITYDANV" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BROSVILL" b2="69 KV" b3="DUMG3" />
      <ContingencyEquipment Action="X" Type="XF" b1="BROSVILL" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103045</SeqNum>
    <Name>L69.Hancock-6645Tap</Name>
    <LastEdit Timestamp="2024-07-15T13:20:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="6645_TAP" b2="69 KV" b3="6645TAPH" />
      <ContingencyEquipment Action="L" Type="LN" b1="6645_TAP" b2="69 KV" b3="HAN-6645" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK4" b2="69 KV" b3="HN6645TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103046</SeqNum>
    <Name>161/69.Pineville.T1416</Name>
    <LastEdit Timestamp="2024-07-15T13:41:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEVIL" b2="69 KV" b3="B192_688" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PINEVIL" b2="161 KV" b3="B192_818" />
      <ContingencyEquipment Action="X" Type="XF" b1="PINEVIL" b2="161 KV" b3="XF1416" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103047</SeqNum>
    <Name>345/138.BlueLick.T157</Name>
    <LastEdit Timestamp="2024-07-15T13:52:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUE_LCK" b2="138 KV" b3="138KVTR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUE_LCK" b2="345 KV" b3="TR14538T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLUE_LCK" b2="345 KV" b3="TR1TR2T" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLUE_LCK" b2="345 KV" b3="XF157" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103048</SeqNum>
    <Name>161/69.TaylorCoLGEE.T185</Name>
    <LastEdit Timestamp="2024-07-17T13:31:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TAYLOR_C" b2="69 KV" b3="B200_608" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TAYLOR_C" b2="161 KV" b3="B200_804" />
      <ContingencyEquipment Action="X" Type="XF" b1="TAYLOR_C" b2="161 KV" b3="XF185" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103049</SeqNum>
    <Name>L500.WMemph-Bhamste-Freepor(WMemphis-Birmingham)</Name>
    <LastEdit Timestamp="2025-11-20T13:55:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="8BHAMSTE" b2="500 KV" b3="BHA-WMEM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="8FREEPOR" b2="500 KV" b3="5034" />
      <ContingencyEquipment Action="OP" Type="CB" b1="8FREEPOR" b2="500 KV" b3="5038" />
      <ContingencyEquipment Action="L" Type="LN" b1="8BHAMSTE" b2="500 KV" b3="BHA-FREE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMEMPH" b2="500 KV" b3="B8810" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WMEMPH" b2="500 KV" b3="B8814" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103053</SeqNum>
    <Name>WildcatWindFarm.U1&amp;U2</Name>
    <LastEdit Timestamp="2026-06-03T14:44:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WCATWIND" b2="34.5 KV" b3="52BT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCATWIND" b2="34.5 KV" b3="52L1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCATWIND" b2="34.5 KV" b3="52L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCATWIND" b2="34.5 KV" b3="52Z1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCATWIND" b2="34.5 KV" b3="52Z2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WCATWIND" b2="34.5 KV" b3="CX11" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WCATWIND" b2="34.5 KV" b3="CX21" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WCATWIND" b2="34.5 KV" b3="WDCAT2WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WCATWIND" b2="34.5 KV" b3="WLDCATWF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103055</SeqNum>
    <Name>L345.Madison-Fayette.34512 </Name>
    <LastEdit Timestamp="2024-07-30T11:50:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="345 KV" b3="JN-DD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="345 KV" b3="JN-FF" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAYETTE2" b2="345 KV" b3="FAY-MAD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON2" b2="345 KV" b3="JM-GG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON2" b2="345 KV" b3="JM-KK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103056</SeqNum>
    <Name>L345.Madison-Fayette.34514 </Name>
    <LastEdit Timestamp="2024-07-30T11:50:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="345 KV" b3="JN-HH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="345 KV" b3="JN-JJ" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAYETTE2" b2="345 KV" b3="FAY-MAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON2" b2="345 KV" b3="JM-EE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISON2" b2="345 KV" b3="JM-FF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103057</SeqNum>
    <Name>345/138.Fayette.BK-E </Name>
    <LastEdit Timestamp="2026-05-11T10:10:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FAYETTE2" b2="345 KV" b3="BK-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="138 KV" b3="JN-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="138 KV" b3="JN-F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="345 KV" b3="JN-GG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="345 KV" b3="JN-HH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103058</SeqNum>
    <Name>345/138.Fayette.BK-W </Name>
    <LastEdit Timestamp="2026-05-11T10:14:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FAYETTE2" b2="345 KV" b3="BK-W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="138 KV" b3="JN-H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="138 KV" b3="JN-K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="345 KV" b3="JN-KK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="345 KV" b3="JN-MM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103059</SeqNum>
    <Name>138/69.Fayette.BK-7 </Name>
    <LastEdit Timestamp="2026-05-11T10:18:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FAYETTE2" b2="138 KV" b3="BK-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="69 KV" b3="JN-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="138 KV" b3="JN-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="138 KV" b3="JN-E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103067</SeqNum>
    <Name>230/69.Clarendon.T_103067</Name>
    <LastEdit Timestamp="2024-07-30T14:55:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARENDN" b2="230 KV" b3="H372" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARENDN" b2="69 KV" b3="L3T122" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLARENDN" b2="230 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103068</SeqNum>
    <Name>DTX138.JugStreet.T3 </Name>
    <LastEdit Timestamp="2024-08-13T18:42:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="138 KV" b3="H013T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JUGSTRET" b2="138 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103069</SeqNum>
    <Name>L138.ElPaso-Minonk-Rutland(ILL/COMED/ILL)</Name>
    <LastEdit Timestamp="2024-08-15T11:48:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="182_MINO" b2="138 KV" b3="TR76_34" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELPASO 3" b2="138 KV" b3="ELP-MINO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELPASO 3" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELPASO 3" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="L" Type="LN" b1="182_MINO" b2="138 KV" b3="182-RTLD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RTLD" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RTLD" b2="138 KV" b3="H7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103070</SeqNum>
    <Name>DTX138.Fayette.L13844</Name>
    <LastEdit Timestamp="2026-05-11T10:26:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FAYETTE2" b2="138 KV" b3="13844" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="138 KV" b3="JN-G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="138 KV" b3="JN-H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103071</SeqNum>
    <Name>DTX138.Fayette.L13845</Name>
    <LastEdit Timestamp="2026-05-13T16:01:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FAYETTE2" b2="138 KV" b3="13845" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="138 KV" b3="JN-L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAYETTE2" b2="138 KV" b3="JN-N" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103072</SeqNum>
    <Name>L230.Belmont-TrappeRock.2311</Name>
    <LastEdit Timestamp="2024-12-17T09:25:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLMNTDOM" b2="230 KV" b3="21802311" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLMNTDOM" b2="230 KV" b3="231112" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLMNTDOM" b2="230 KV" b3="BLM-TRAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRAPROCK" b2="230 KV" b3="231142-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRAPROCK" b2="230 KV" b3="231142-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103074</SeqNum>
    <Name>230/69.SouthAkron.T5</Name>
    <LastEdit Timestamp="2024-08-30T09:50:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SAKRON" b2="230 KV" b3="5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="TRAN5_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="230 KV" b3="TRAN5_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="69 KV" b3="TRAN_5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103077</SeqNum>
    <Name>L345.OraOra-Olive</Name>
    <LastEdit Timestamp="2024-09-03T14:56:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="345 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OLIVE" b2="345 KV" b3="E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="OLIVE" b2="345 KV" b3="OLI-ORAO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORAORA" b2="345 KV" b3="M007A8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORAORA" b2="345 KV" b3="M007B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103078</SeqNum>
    <Name>OraOra.MammothNorthSolar</Name>
    <LastEdit Timestamp="2024-09-03T15:03:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ORAORA" b2="345 KV" b3="M007B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ORAORA" b2="345 KV" b3="M007B5" />
      <ContingencyEquipment Action="X" Type="XF" b1="ORAORA" b2="345 KV" b3="MPT1" />
      <ContingencyEquipment Action="X" Type="XF" b1="ORAORA" b2="345 KV" b3="MPT2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ORAORA" b2="34.5 KV" b3="ORAORASP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103079</SeqNum>
    <Name>L345.Clinton-LegHorn.1 [ILL_EQ]</Name>
    <LastEdit Timestamp="2024-09-06T14:01:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON4" b2="345 KV" b3="BT4518" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON4" b2="345 KV" b3="BT4522" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINTON4" b2="345 KV" b3="CLI-LEGH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGH" b2="345 KV" b3="V15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGH" b2="345 KV" b3="V23" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103080</SeqNum>
    <Name>L345.LegHorn-Oreana.2 [ILL_EQ]</Name>
    <LastEdit Timestamp="2024-09-06T14:02:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGH" b2="345 KV" b3="V21" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEGH" b2="345 KV" b3="V23" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEGH" b2="345 KV" b3="LEG-ORE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OREANA" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OREANA" b2="345 KV" b3="V5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103082</SeqNum>
    <Name>L230.MtVernon-Waterfront.23142</Name>
    <LastEdit Timestamp="2024-09-06T07:28:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MTVERPEP" b2="230 KV" b3="2A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTVERPEP" b2="230 KV" b3="2B" />
      <ContingencyEquipment Action="L" Type="LN" b1="MTVERPEP" b2="230 KV" b3="MTV-WAT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="4BCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATERFRO" b2="230 KV" b3="4CCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103083</SeqNum>
    <Name>L138.FiveForks-Rivervil</Name>
    <LastEdit Timestamp="2024-09-10T11:28:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FIVEFRAP" b2="138 KV" b3="GLADSTON" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIL" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIVERVIL" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="FIVEFRAP" b2="138 KV" b3="FIV-RIVE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103084</SeqNum>
    <Name>L230.Aviator-Celestial.2137</Name>
    <LastEdit Timestamp="2025-04-30T10:12:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AVIATOR" b2="230 KV" b3="213752-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AVIATOR" b2="230 KV" b3="213752-7" />
      <ContingencyEquipment Action="L" Type="LN" b1="AVIATOR" b2="230 KV" b3="AVI-CELE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELESTIA" b2="230 KV" b3="21372261" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELESTIA" b2="230 KV" b3="213732" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103088</SeqNum>
    <Name>L115.ChaseCity-Cemetry-Herbert.171</Name>
    <LastEdit Timestamp="2024-09-17T12:50:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CEMETRY" b2="115 KV" b3="H152" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CEMETRY" b2="13 KV" b3="LD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CEMETRY" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHASECTY" b2="115 KV" b3="17112" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEMETRY" b2="115 KV" b3="CEM-CHAS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHASECTY" b2="115 KV" b3="H212" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHASECTY" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHASECTY" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERBERT2" b2="115 KV" b3="17102" />
      <ContingencyEquipment Action="L" Type="LN" b1="CEMETRY" b2="115 KV" b3="CEM-HERB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERBERT2" b2="115 KV" b3="H2T171" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103089</SeqNum>
    <Name>230/69.Acahela.1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-21T15:23:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ACAHELA" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ACAHELA" b2="69 KV" b3="TRAN1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ACAHELA" b2="230 KV" b3="TRANS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103090</SeqNum>
    <Name>230/69.Acahela.2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-21T15:24:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ACAHELA" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ACAHELA" b2="69 KV" b3="TRAN2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ACAHELA" b2="230 KV" b3="TRANS2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103091</SeqNum>
    <Name>230/69.Berks.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-21T15:25:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BERKS" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BERKS" b2="230 KV" b3="TRAN1MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKS" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103092</SeqNum>
    <Name>230/69.Berks.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-22T10:26:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BERKS" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BERKS" b2="230 KV" b3="TRAN2MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERKS" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103093</SeqNum>
    <Name>230/69.BloomingGrove.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-21T15:26:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BLOOMING" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BLOOMING" b2="230 KV" b3="TRAN1MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLOOMING" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103094</SeqNum>
    <Name>230/69.BloomingGrove.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-22T10:29:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BLOOMING" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BLOOMING" b2="230 KV" b3="TRAN2MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLOOMING" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103095</SeqNum>
    <Name>230/69.Buxmont.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-21T15:27:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BUXMONT" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUXMONT" b2="230 KV" b3="TRAN1MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUXMONT" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103096</SeqNum>
    <Name>230/69.Buxmont.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-21T15:27:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="BUXMONT" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BUXMONT" b2="230 KV" b3="TRAN2MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUXMONT" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103097</SeqNum>
    <Name>230/69.Clinton.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-21T15:30:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CLINTON" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLINTON" b2="230 KV" b3="TRAN1MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103098</SeqNum>
    <Name>230/69.Clinton.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-21T15:31:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CLINTON" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CLINTON" b2="230 KV" b3="TRAN2MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103099</SeqNum>
    <Name>230/69.Columbia.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-21T15:32:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="COLU PL" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COLU PL" b2="230 KV" b3="TRAN1MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103100</SeqNum>
    <Name>230/69.Columbia.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-22T10:30:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="COLU PL" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COLU PL" b2="230 KV" b3="TRAN2MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103101</SeqNum>
    <Name>230/69.Cumberland.T1</Name>
    <LastEdit Timestamp="2026-05-12T10:17:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CUMB PL" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="230 KV" b3="TR1_WGR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="230 KV" b3="TRAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103102</SeqNum>
    <Name>230/69.Cumberland.T2</Name>
    <LastEdit Timestamp="2026-01-20T14:09:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CUMB PL" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="230 KV" b3="TR2_JUN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="230 KV" b3="TRAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103104</SeqNum>
    <Name>230/69.WestHempfield.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T11:24:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WHEMPFIE" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WHEMPFIE" b2="230 KV" b3="TRAN2MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103106</SeqNum>
    <Name>230/69.WestHempfield.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T11:38:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WHEMPFIE" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WHEMPFIE" b2="230 KV" b3="TRAN1MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEMPFIE" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103108</SeqNum>
    <Name>230/69.Stanton.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-10-03T15:38:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="STANTON" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STANTON" b2="230 KV" b3="TRAN4MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANTON" b2="69 KV" b3="TRAN_4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103110</SeqNum>
    <Name>230/69.Stanton.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T11:51:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="STANTON" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STANTON" b2="230 KV" b3="TRAN3MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANTON" b2="69 KV" b3="TRAN_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103112</SeqNum>
    <Name>230/69.Stanton.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T11:55:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="STANTON" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STANTON" b2="230 KV" b3="TRAN2MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANTON" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103114</SeqNum>
    <Name>230/69.Stanton.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T11:59:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="STANTON" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="STANTON" b2="230 KV" b3="TRAN1MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STANTON" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103118</SeqNum>
    <Name>230/69.SouthManheim.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T13:31:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SMANHEIM" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMANHEIM" b2="230 KV" b3="TRAN3MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMANHEIM" b2="69 KV" b3="TRAN_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103120</SeqNum>
    <Name>230/69.SouthManheim.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T13:35:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SMANHEIM" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMANHEIM" b2="230 KV" b3="TRAN4MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMANHEIM" b2="69 KV" b3="TRAN_4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103122</SeqNum>
    <Name>230/69.SouthAkron.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T13:40:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SAKRON" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SAKRON" b2="230 KV" b3="TRAN4MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="69 KV" b3="TRAN_4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103124</SeqNum>
    <Name>230/69.SouthAkron.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T13:44:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SAKRON" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SAKRON" b2="230 KV" b3="TRAN3MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAKRON" b2="69 KV" b3="TRAN_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103130</SeqNum>
    <Name>230/138.Monroe.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T14:12:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MONR PL" b2="230 KV" b3="2 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR PL" b2="138 KV" b3="TRAN2LS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONR PL" b2="230 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103132</SeqNum>
    <Name>230/69.Millwood.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T14:18:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MILLWDPL" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MILLWDPL" b2="230 KV" b3="T1 HSDIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLWDPL" b2="69 KV" b3="T1 LS CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103134</SeqNum>
    <Name>230/69.Millwood.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T14:20:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MILLWDPL" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MILLWDPL" b2="230 KV" b3="T2 HSDIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MILLWDPL" b2="69 KV" b3="T2 LS CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103136</SeqNum>
    <Name>230/69.Manor.T3 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-11-21T09:13:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MANOR" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="230 KV" b3="TRAN3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="TRAN_3-N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="TRAN_3-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103138</SeqNum>
    <Name>230/69.Manor.T4 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T14:30:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="MANOR" b2="230 KV" b3="4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MANOR" b2="69 KV" b3="TRAN4-CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MANOR" b2="230 KV" b3="TRAN4-DI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103140</SeqNum>
    <Name>230/69.Hummelstown.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-20T14:42:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HUMMELST" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="230 KV" b3="TRAN_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="69 KV" b3="TRAN_2-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="69 KV" b3="TRAN_2-W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103144</SeqNum>
    <Name>230/69.Dauphin.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-21T15:21:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DAUPHIN" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DAUPHIN" b2="230 KV" b3="TRAN1MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAUPHIN" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103145</SeqNum>
    <Name>230/69.Dauphin.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-21T15:21:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DAUPHIN" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="DAUPHIN" b2="230 KV" b3="TRAN2MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DAUPHIN" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103146</SeqNum>
    <Name>230/69.EastPalmerton.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-21T15:22:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EPALMERT" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EPALMERT" b2="230 KV" b3="TRAN1MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EPALMERT" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103147</SeqNum>
    <Name>230/69.EastPalmerton.T2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-22T10:36:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="EPALMERT" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="EPALMERT" b2="230 KV" b3="TRAN2MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EPALMERT" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103148</SeqNum>
    <Name>230/69.Eldred.TR1 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-21T15:22:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ELDRED" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELDRED" b2="230 KV" b3="TRAN1MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDRED" b2="69 KV" b3="TRAN_1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103149</SeqNum>
    <Name>230/69.Eldred.TR2 (Sctnlz)</Name>
    <LastEdit Timestamp="2024-09-22T10:41:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ELDRED" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ELDRED" b2="230 KV" b3="TRAN2MOD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDRED" b2="69 KV" b3="TRAN_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103150</SeqNum>
    <Name>138/69.Amherst.XFMR</Name>
    <LastEdit Timestamp="2024-09-23T12:07:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AMHERST" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="X" Type="XF" b1="AMHERST" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMHERST" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103151</SeqNum>
    <Name>L138.Brim-Midway</Name>
    <LastEdit Timestamp="2024-09-23T14:56:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02BRIM" b2="138 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02BRIM" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="02BRIM" b2="138 KV" b3="BRI-MIDW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDWAYTE" b2="138 KV" b3="B13302" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103153</SeqNum>
    <Name>230/69.Frackville.TRAN1</Name>
    <LastEdit Timestamp="2024-09-24T10:07:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="230 KV" b3="TR1_SIEG" />
      <ContingencyEquipment Action="X" Type="XF" b1="FRACKVIL" b2="230 KV" b3="TRAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="230 KV" b3="TRAN1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="TRAN1LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103154</SeqNum>
    <Name>230/69.Frackville.TRAN3</Name>
    <LastEdit Timestamp="2025-02-04T06:13:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="230 KV" b3="TR3_COLU" />
      <ContingencyEquipment Action="X" Type="XF" b1="FRACKVIL" b2="230 KV" b3="TRAN3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="230 KV" b3="TRAN3CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="TRAN3LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103155</SeqNum>
    <Name>230/69.Frackville.TRAN2</Name>
    <LastEdit Timestamp="2025-04-25T09:02:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FRACKVIL" b2="230 KV" b3="TRAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="TRAN2_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="230 KV" b3="TRAN2_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="230 KV" b3="TRAN2_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRACKVIL" b2="69 KV" b3="TRAN2_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103156</SeqNum>
    <Name>L345.Schahfer-Hinshaw (NIPS)</Name>
    <LastEdit Timestamp="2024-09-24T13:07:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HINSHAW" b2="345 KV" b3="13N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINSHAW" b2="345 KV" b3="13S" />
      <ContingencyEquipment Action="L" Type="LN" b1="HINSHAW" b2="345 KV" b3="HIN-SCHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCHAHFER" b2="345 KV" b3="13U14" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103157</SeqNum>
    <Name>L138.Ameriplex-Boundary</Name>
    <LastEdit Timestamp="2025-11-06T11:02:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMERIPLX" b2="138 KV" b3="AME-BOUN" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMERIPLX" b2="138 KV" b3="AME-PINE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AMERIPLX" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMERIPLX" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOUNDARY" b2="138 KV" b3="M003H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOUNDARY" b2="138 KV" b3="M003H8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103158</SeqNum>
    <Name>L69.Grasonville-Queenstown</Name>
    <LastEdit Timestamp="2024-09-26T12:26:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GRSNVILL" b2="69 KV" b3="7690" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUEENTWN" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUEENTWN" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRSNVILL" b2="69 KV" b3="GRS-QUE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103159</SeqNum>
    <Name>L345.Jordan-Massac (ILL/MISO)</Name>
    <LastEdit Timestamp="2024-09-26T12:12:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JORD" b2="345 KV" b3="JOR-MASS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JORD" b2="345 KV" b3="V25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JORD" b2="345 KV" b3="V33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASSAC" b2="345 KV" b3="V35" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASSAC" b2="345 KV" b3="V43" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103161</SeqNum>
    <Name>230/35.Hopewell.TX7</Name>
    <LastEdit Timestamp="2024-10-03T11:47:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="230 KV" b3="H732" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPEWEL4" b2="35 KV" b3="L732" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOPEWEL4" b2="230 KV" b3="TX7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103162</SeqNum>
    <Name>L230.Livingston-Roseland.B-2333</Name>
    <LastEdit Timestamp="2024-10-03T15:43:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIVINGPS" b2="230 KV" b3="1-2CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LIVINGPS" b2="230 KV" b3="T-20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIVINGPS" b2="230 KV" b3="T-20B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="18-22" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROSELAND" b2="230 KV" b3="21-22" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIVINGPS" b2="230 KV" b3="LIV-ROSE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103163</SeqNum>
    <Name>DTX138.Anguin.DEVITO1</Name>
    <LastEdit Timestamp="2026-05-08T14:46:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ANGUIN" b2="138 KV" b3="DEVITO1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="H009G5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="H022W8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103174</SeqNum>
    <Name>L138.Anguin-Brie.1</Name>
    <LastEdit Timestamp="2024-10-09T10:08:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANGUIN" b2="138 KV" b3="ANG-BRI1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H002V5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H002V8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103175</SeqNum>
    <Name>L138.Anguin-Macy</Name>
    <LastEdit Timestamp="2024-10-09T10:10:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ANGUIN" b2="138 KV" b3="ANG-MACY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACYOP" b2="138 KV" b3="H018U2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACYOP" b2="138 KV" b3="H018U8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103176</SeqNum>
    <Name>L138.Brie-Macy</Name>
    <LastEdit Timestamp="2024-10-09T10:12:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRIE" b2="138 KV" b3="BRI-MACY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H002W5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H002W8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACYOP" b2="138 KV" b3="H018U5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACYOP" b2="138 KV" b3="H018X2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103177</SeqNum>
    <Name>DTX138.Macy.TR1</Name>
    <LastEdit Timestamp="2024-10-09T10:14:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MACYOP" b2="138 KV" b3="H018U2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACYOP" b2="138 KV" b3="H018U5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MACYOP" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103178</SeqNum>
    <Name>DTX138.Macy.TR2</Name>
    <LastEdit Timestamp="2024-10-09T10:14:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MACYOP" b2="138 KV" b3="H018U8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACYOP" b2="138 KV" b3="H018X2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MACYOP" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103179</SeqNum>
    <Name>Diamond.FountainCreek.SP</Name>
    <LastEdit Timestamp="2024-10-09T11:18:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DIAMONDG" b2="115 KV" b3="FTCRKCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="DIAMONDG" b2="115 KV" b3="FTCRKGSU" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DIAMONDG" b2="34.5 KV" b3="FTCRKSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103182</SeqNum>
    <Name>L138.LongCreek-Bartonville</Name>
    <LastEdit Timestamp="2024-10-14T13:38:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BARTONVI" b2="138 KV" b3="BAR-LONG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARTONVI" b2="138 KV" b3="BUS TIE" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BARTONVI" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BARTONVI" b2="138 KV" b3="CAP1 CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BARTONVI" b2="34.5 KV" b3="HPHOODCT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BARTONVI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BARTONVI" b2="34.5 KV" b3="T3" />
      <ContingencyEquipment Action="X" Type="XF" b1="BARTONVI" b2="138 KV" b3="XF3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGCREE" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGCREE" b2="138 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103183</SeqNum>
    <Name>LongCreek.Bartonsville.SP</Name>
    <LastEdit Timestamp="2024-10-10T14:49:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGCREE" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LONGCREE" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LONGCREE" b2="34.5 KV" b3="BARTONSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="LONGCREE" b2="138 KV" b3="GSU1" />
      <ContingencyEquipment Action="X" Type="XF" b1="LONGCREE" b2="138 KV" b3="GSU2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103185</SeqNum>
    <Name>L138.Spickard-ClintonCo-Warren</Name>
    <LastEdit Timestamp="2024-10-10T15:07:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08WARREN" b2="138 KV" b3="873" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINTONC" b2="138 KV" b3="CLI-WAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLINTONC" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLINTONC" b2="138 KV" b3="CLNTONBS" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINTONC" b2="138 KV" b3="CLI-SPIC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPICKARD" b2="138 KV" b3="H014W2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPICKARD" b2="138 KV" b3="H014W5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103187</SeqNum>
    <Name>L138.HarrisonCounty-Renaker</Name>
    <LastEdit Timestamp="2024-10-18T16:23:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRCOEK" b2="138 KV" b3="N101-814" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARRCOEK" b2="138 KV" b3="N101-817" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RENAKER" b2="138 KV" b3="CB814" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRCOEK" b2="138 KV" b3="HAR-RENA" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="RENAKER" b2="138 KV" b3="SW817" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103188</SeqNum>
    <Name>Pembroke.Timber.WF</Name>
    <LastEdit Timestamp="2024-10-16T11:29:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PEMBROKE" b2="230 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PEMBROKE" b2="230 KV" b3="GSU_HSCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PEMBROKE" b2="34.5 KV" b3="TIMBERWF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103191</SeqNum>
    <Name>Kiser.Clearview.SP</Name>
    <LastEdit Timestamp="2025-02-18T13:07:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="KISER" b2="34.5 KV" b3="CLEARVSP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KISER" b2="138 KV" b3="EB-C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KISER" b2="138 KV" b3="EB-F" />
      <ContingencyEquipment Action="X" Type="XF" b1="KISER" b2="138 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103198</SeqNum>
    <Name>L230.Thunderball-Brambleton.206B</Name>
    <LastEdit Timestamp="2024-10-28T16:01:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="20602" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="206T2227" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THUNDERB" b2="230 KV" b3="20642-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THUNDERB" b2="230 KV" b3="20642-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRAMBLET" b2="230 KV" b3="BRA-THUN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103199</SeqNum>
    <Name>DTX230.Thunderball.LD1</Name>
    <LastEdit Timestamp="2024-10-28T16:02:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="THUNDERB" b2="230 KV" b3="20642-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THUNDERB" b2="230 KV" b3="230842-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THUNDERB" b2="230 KV" b3="LD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103200</SeqNum>
    <Name>DTX230.Thunderball.LD2</Name>
    <LastEdit Timestamp="2024-10-28T16:03:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="THUNDERB" b2="230 KV" b3="20642-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="THUNDERB" b2="230 KV" b3="230842-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THUNDERB" b2="230 KV" b3="LD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103201</SeqNum>
    <Name>Groton.Wheatsborough.SP</Name>
    <LastEdit Timestamp="2024-10-29T16:44:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="GROTON" b2="138 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GROTON" b2="138 KV" b3="GSUHCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GROTON" b2="34.5 KV" b3="GSULCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GROTON" b2="34.5 KV" b3="WHEATBSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103202</SeqNum>
    <Name>L345.Hinshaw-Dunbrsf2 (NIPS)</Name>
    <LastEdit Timestamp="2024-10-31T11:18:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNBRSF2" b2="345 KV" b3="41" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DUNBRSF2" b2="345 KV" b3="DBS2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="DUNBRSF2" b2="345 KV" b3="DSF2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINSHAW" b2="345 KV" b3="41N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINSHAW" b2="345 KV" b3="41S" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUNBRSF2" b2="345 KV" b3="DUN-HINS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103203</SeqNum>
    <Name>HarrisonCounty.BlueBird.SP</Name>
    <LastEdit Timestamp="2024-11-05T09:12:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRCOEK" b2="138 KV" b3="BLUE_CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HARRCOEK" b2="34.5 KV" b3="BLUE_SP" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARRCOEK" b2="138 KV" b3="TX1-9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103204</SeqNum>
    <Name>138/69/34.FortRobison.TR1</Name>
    <LastEdit Timestamp="2024-11-05T09:26:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="FORTROBI" b2="138 KV" b3="1-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="FORTROBI" b2="69 KV" b3="1-S" />
      <ContingencyEquipment Action="X" Type="XF" b1="FORTROBI" b2="34.5 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORTROBI" b2="69 KV" b3="A001G8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORTROBI" b2="138 KV" b3="A001H8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORTROBI" b2="34.5 KV" b3="A001J2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103205</SeqNum>
    <Name>L138.FortRobison-WolfHills</Name>
    <LastEdit Timestamp="2024-11-05T09:33:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FORTROBI" b2="138 KV" b3="A001H5" />
      <ContingencyEquipment Action="L" Type="LN" b1="FORTROBI" b2="138 KV" b3="FOR-WOL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WOLFHILL" b2="138 KV" b3="A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103206</SeqNum>
    <Name>L138.LafayetteSouth-Shadeland-Tippecanoe</Name>
    <LastEdit Timestamp="2024-11-06T12:12:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAFAYSOU" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHADELND" b2="138 KV" b3="BK1 LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAFAYSOU" b2="138 KV" b3="LAF-SHA" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHADELND" b2="138 KV" b3="SHA-TIP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIPPECAN" b2="138 KV" b3="2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103207</SeqNum>
    <Name>138/34.Hancock.T6</Name>
    <LastEdit Timestamp="2024-11-05T14:16:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="HANCOCK" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK" b2="138 KV" b3="A006D5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANCOCK" b2="34 KV" b3="A006D8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103208</SeqNum>
    <Name>DTX230.Northwood.2Bank</Name>
    <LastEdit Timestamp="2024-11-05T14:53:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NORTHWOO" b2="230 KV" b3="2 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="230 KV" b3="B27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="230 KV" b3="B30" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103211</SeqNum>
    <Name>L230.Echelon-Marlton-CoxsCorner.W-2223</Name>
    <LastEdit Timestamp="2024-11-06T15:25:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COXSCORN" b2="230 KV" b3="COX-MARW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COXSCORN" b2="230 KV" b3="SECT1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COXSCORN" b2="230 KV" b3="SECT3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ECHELON" b2="230 KV" b3="1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ECHELON" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="ECHELON" b2="230 KV" b3="ECH-MARL" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MARLTON" b2="230 KV" b3="T1-2TRAN" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="MARLTON" b2="230 KV" b3="T3-4TRAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103213</SeqNum>
    <Name>L138.Corey-StubeyRoad</Name>
    <LastEdit Timestamp="2024-11-18T12:58:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COREY" b2="138 KV" b3="COR-STUB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COREY" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COREY" b2="138 KV" b3="H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="138 KV" b3="M000Z5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="138 KV" b3="M001A2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103214</SeqNum>
    <Name>L230.Bergen-NorthBergen.M-2344</Name>
    <LastEdit Timestamp="2024-11-21T10:01:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="15-16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERGEN" b2="230 KV" b3="4-16" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERGEN" b2="230 KV" b3="BER-NBE3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NBERGEN" b2="230 KV" b3="3-4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NBERGEN" b2="230 KV" b3="T10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103215</SeqNum>
    <Name>L138.Kenna-Sisson</Name>
    <LastEdit Timestamp="2024-11-15T07:28:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNA" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENNA" b2="138 KV" b3="KEN-SISS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SISSON" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SISSON" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103216</SeqNum>
    <Name>L138.Kenna-Ripley</Name>
    <LastEdit Timestamp="2024-11-15T07:28:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="KENNA" b2="138 KV" b3="KEN-RIPL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNA" b2="138 KV" b3="L" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIPLEY" b2="138 KV" b3="F" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103217</SeqNum>
    <Name>L69.Sturgis-StubeyRoad</Name>
    <LastEdit Timestamp="2024-11-18T12:58:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="69 KV" b3="M000X5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="69 KV" b3="M000X8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STURGIS" b2="69 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="STUBYROA" b2="69 KV" b3="STU-STU1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103218</SeqNum>
    <Name>L138.Mclean-Normal</Name>
    <LastEdit Timestamp="2024-11-11T07:37:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCLEAN" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCLEAN" b2="138 KV" b3="H7" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCLEAN" b2="138 KV" b3="MCL-NORM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORMAL 3" b2="138 KV" b3="H11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORMAL 3" b2="138 KV" b3="H9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103222</SeqNum>
    <Name>L345.Cyprus-Bixby</Name>
    <LastEdit Timestamp="2024-11-13T08:43:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BIXBY" b2="345 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BIXBY" b2="345 KV" b3="BIX-CYPR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="345 KV" b3="H017F8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="345 KV" b3="H017Y5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103223</SeqNum>
    <Name>L138.Kewanee-CedarCreek</Name>
    <LastEdit Timestamp="2024-11-12T15:42:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CEDARCR2" b2="138 KV" b3="CED-KEWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CEDARCR2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEWANEE2" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEWANEE2" b2="138 KV" b3="H" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103224</SeqNum>
    <Name>L138.Boxwood-Reusens</Name>
    <LastEdit Timestamp="2024-11-13T09:10:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BOXWOOD" b2="138 KV" b3="BOX-REU1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOXWOOD" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOXWOOD" b2="138 KV" b3="K" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REUSENS" b2="138 KV" b3="E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103225</SeqNum>
    <Name>L345.Hayden-Beacon</Name>
    <LastEdit Timestamp="2024-11-13T09:35:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEACON" b2="345 KV" b3="H007P5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEACON" b2="345 KV" b3="H007P8" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEACON" b2="345 KV" b3="BEA-HAYD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYDEN" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYDEN" b2="345 KV" b3="C2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103226</SeqNum>
    <Name>DTX138.Pierpont.T2</Name>
    <LastEdit Timestamp="2024-11-13T09:51:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERPONT" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIERPONT" b2="138 KV" b3="B5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PIERPONT" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103228</SeqNum>
    <Name>DTX138.Cly.TR1</Name>
    <LastEdit Timestamp="2024-11-13T15:22:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLY" b2="115 KV" b3="B47" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLY" b2="115 KV" b3="B7" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLY" b2="115 KV" b3="LD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103230</SeqNum>
    <Name>L115.ShadeGap-AspenSolar</Name>
    <LastEdit Timestamp="2024-11-27T09:30:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ASPENSLR" b2="115 KV" b3="ASP-SHAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASPENSLR" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASPENSLR" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHADEGAP" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHADEGAP" b2="115 KV" b3="D16" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103231</SeqNum>
    <Name>L115.Roxbury-AspenSolar</Name>
    <LastEdit Timestamp="2024-11-27T09:32:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ASPENSLR" b2="115 KV" b3="ASP-ROXB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASPENSLR" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASPENSLR" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBURY" b2="115 KV" b3="B33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROXBURY" b2="115 KV" b3="B34" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103232</SeqNum>
    <Name>AspenRoad.SP </Name>
    <LastEdit Timestamp="2024-11-27T09:57:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ASPENSLR" b2="34.5 KV" b3="ASPNRDCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ASPENSLR" b2="34.5 KV" b3="ASPNRDSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="ASPENSLR" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ASPENSLR" b2="115 KV" b3="GSU_H_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103237</SeqNum>
    <Name>L138.Richland-Lammer</Name>
    <LastEdit Timestamp="2024-11-27T09:47:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMMER" b2="138 KV" b3="H024M5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAMMER" b2="138 KV" b3="H024Q2" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAMMER" b2="138 KV" b3="LAM-RICH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RICHLND" b2="138 KV" b3="B13250" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103238</SeqNum>
    <Name>L345.Trumbull-Highland</Name>
    <LastEdit Timestamp="2024-11-27T09:48:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="172" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIGHLAOE" b2="345 KV" b3="175" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRUMBUL2" b2="345 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRUMBUL2" b2="345 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIGHLAOE" b2="345 KV" b3="HIG-TRUM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103239</SeqNum>
    <Name>DTX138.Talmadge.TR3</Name>
    <LastEdit Timestamp="2024-11-27T09:50:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TALWGATE" b2="138 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TALWGATE" b2="138 KV" b3="B30" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TALWGATE" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103247</SeqNum>
    <Name>DTX138.Remington.BK2&amp;4</Name>
    <LastEdit Timestamp="2024-12-05T15:10:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGT" b2="138 KV" b3="830" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGT" b2="138 KV" b3="834" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REMINGT" b2="138 KV" b3="BK2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REMINGT" b2="138 KV" b3="BK4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103248</SeqNum>
    <Name>DTX138.Remington.BK1&amp;3</Name>
    <LastEdit Timestamp="2025-04-08T13:45:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGT" b2="138 KV" b3="829" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REMINGT" b2="138 KV" b3="830" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REMINGT" b2="138 KV" b3="BK1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REMINGT" b2="138 KV" b3="BK3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103249</SeqNum>
    <Name>DTX230.Nivo.T1&amp;2</Name>
    <LastEdit Timestamp="2024-12-05T15:22:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NIVO" b2="230 KV" b3="H12T2116" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NIVO" b2="230 KV" b3="H12T2130" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NIVO" b2="36.5 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NIVO" b2="36.5 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="NIVO" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="NIVO" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103250</SeqNum>
    <Name>DTX230.Nivo.T3</Name>
    <LastEdit Timestamp="2026-02-11T06:55:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NIVO" b2="230 KV" b3="H34T2116" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NIVO" b2="230 KV" b3="H34T2130" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NIVO" b2="36.5 KV" b3="T3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NIVO" b2="36.5 KV" b3="T4LD" />
      <ContingencyEquipment Action="X" Type="XF" b1="NIVO" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="NIVO" b2="230 KV" b3="TX4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103251</SeqNum>
    <Name>DTX230.Northwood.3Bank</Name>
    <LastEdit Timestamp="2024-12-05T16:06:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NORTHWOO" b2="230 KV" b3="3 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="230 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="230 KV" b3="B29" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103252</SeqNum>
    <Name>L138.Sporn-Polymer-KeraLakes</Name>
    <LastEdit Timestamp="2024-12-13T05:53:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KERALAKE" b2="138 KV" b3="A008D5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERALAKE" b2="138 KV" b3="A008D8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POLYMER" b2="138 KV" b3="ARMSTRNG" />
      <ContingencyEquipment Action="L" Type="LN" b1="KERALAKE" b2="138 KV" b3="KER-POLY" />
      <ContingencyEquipment Action="L" Type="LN" b1="POLYMER" b2="138 KV" b3="POL-SPS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POLYMER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="V" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPORNAEP" b2="138 KV" b3="V1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103253</SeqNum>
    <Name>345/138.Cyprus.TR1</Name>
    <LastEdit Timestamp="2024-12-05T16:29:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000F2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H000F5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="345 KV" b3="H017Y2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="345 KV" b3="H017Y5" />
      <ContingencyEquipment Action="X" Type="XF" b1="CYPRUS" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103254</SeqNum>
    <Name>345/138.Cyprus.TR2</Name>
    <LastEdit Timestamp="2024-12-10T16:22:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="345 KV" b3="H017F8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H017V2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H017V5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="345 KV" b3="H017Y8" />
      <ContingencyEquipment Action="X" Type="XF" b1="CYPRUS" b2="345 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103257</SeqNum>
    <Name>DTX138.Sisson.T1</Name>
    <LastEdit Timestamp="2024-12-12T13:41:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SISSON" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SISSON" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SISSON" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103258</SeqNum>
    <Name>L230.Sewaren-Deans.2207</Name>
    <LastEdit Timestamp="2024-12-05T17:23:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DEANS" b2="230 KV" b3="DEA-SEWA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="230 KV" b3="SECT 1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEANS" b2="230 KV" b3="SECT 7-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="11-12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEWAREN" b2="230 KV" b3="2-12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103260</SeqNum>
    <Name>L345.ABBrown-Polyeast (External)</Name>
    <LastEdit Timestamp="2024-12-18T10:10:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ABBROWN" b2="345 KV" b3="3000" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ABBROWN" b2="345 KV" b3="4000" />
      <ContingencyEquipment Action="L" Type="LN" b1="ABBROWN" b2="345 KV" b3="ABB-POLY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POLYEAST" b2="345 KV" b3="3100" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POLYEAST" b2="345 KV" b3="3300" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103261</SeqNum>
    <Name>230/115.Locks.TX7</Name>
    <LastEdit Timestamp="2024-12-09T15:03:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKS" b2="230 KV" b3="H7T249" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKS" b2="115 KV" b3="L722" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOCKS" b2="230 KV" b3="TX7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103263</SeqNum>
    <Name>Seabrook.U1 (NEISO)</Name>
    <LastEdit Timestamp="2025-09-15T13:41:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SEABROOK" b2="345 KV" b3="11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEABROOK" b2="345 KV" b3="12" />
      <ContingencyEquipment Action="X" Type="XF" b1="SEABROOK" b2="345 KV" b3="1X" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SEABROOK" b2="24 KV" b3="SBRK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103265</SeqNum>
    <Name>230/26.Lawrence.220-1</Name>
    <LastEdit Timestamp="2024-12-12T14:18:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LAWRENCE" b2="230 KV" b3="220-1 TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="230 KV" b3="220-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LAWRENCE" b2="26 KV" b3="BUSDUMMY" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAWRENCE" b2="26 KV" b3="LOAD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103266</SeqNum>
    <Name>L115.Cly-ES3CONEW-Raintree-SmithSt</Name>
    <LastEdit Timestamp="2024-12-13T11:00:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLY" b2="115 KV" b3="B15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLY" b2="115 KV" b3="B23" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLY" b2="115 KV" b3="CLY-ES3" />
      <ContingencyEquipment Action="L" Type="LN" b1="ES3CONEW" b2="115 KV" b3="ES3-RAI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ES3CONEW" b2="115 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RAINTREE" b2="115 KV" b3="LOAD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RAINTREE" b2="115 KV" b3="LOAD2" />
      <ContingencyEquipment Action="L" Type="LN" b1="RAINTREE" b2="115 KV" b3="RAI-SMI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SMITHST" b2="115 KV" b3="B97802" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SMITHST" b2="115 KV" b3="D97808" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103269</SeqNum>
    <Name>L230.Altair-TrappeRock.2263</Name>
    <LastEdit Timestamp="2024-12-17T09:15:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAIR" b2="230 KV" b3="226372-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAIR" b2="230 KV" b3="226372-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALTAIR" b2="230 KV" b3="ALT-TRAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRAPROCK" b2="230 KV" b3="226342-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRAPROCK" b2="230 KV" b3="226342-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103270</SeqNum>
    <Name>L230.Brambleton-Northstar.2319</Name>
    <LastEdit Timestamp="2024-12-18T08:58:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="201T2319" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="230 KV" b3="231902" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRAMBLET" b2="230 KV" b3="BRA-NRTH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHSTAR" b2="230 KV" b3="231962-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHSTAR" b2="230 KV" b3="231962-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103271</SeqNum>
    <Name>L138.Hoffman-E535Microsoft.21403</Name>
    <LastEdit Timestamp="2025-04-01T15:48:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="1-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E535" b2="138 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E535" b2="138 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="E535" b2="138 KV" b3="21403" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103272</SeqNum>
    <Name>DTX138.Hoffman.T73</Name>
    <LastEdit Timestamp="2026-01-20T13:34:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="3-4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="214 HOFF" b2="138 KV" b3="TR73 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103273</SeqNum>
    <Name>DTX138.Hoffman.T74 </Name>
    <LastEdit Timestamp="2026-06-05T10:27:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="1-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="7-8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="214 HOFF" b2="138 KV" b3="TR74 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103274</SeqNum>
    <Name>DTX138.Hoffman.T71</Name>
    <LastEdit Timestamp="2026-03-31T10:35:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="12-13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="13-14" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="214 HOFF" b2="138 KV" b3="TR71 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103275</SeqNum>
    <Name>DTX138.Hoffman.T72 </Name>
    <LastEdit Timestamp="2025-11-06T15:16:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="10-11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="9-10" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="214 HOFF" b2="138 KV" b3="TR72 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103276</SeqNum>
    <Name>L138.Hoffman-E535Microsoft.21408</Name>
    <LastEdit Timestamp="2025-05-13T08:40:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="12-16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="15-16" />
      <ContingencyEquipment Action="L" Type="LN" b1="E535" b2="138 KV" b3="21408" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E535" b2="138 KV" b3="5-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E535" b2="138 KV" b3="7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103277</SeqNum>
    <Name>DTX138.E535.TR73</Name>
    <LastEdit Timestamp="2025-05-30T10:04:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="E535" b2="138 KV" b3="6-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E535" b2="138 KV" b3="7-8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="E535" b2="138 KV" b3="TR73" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103278</SeqNum>
    <Name>DTX138.E535.TR72</Name>
    <LastEdit Timestamp="2025-06-03T11:31:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="E535" b2="138 KV" b3="5-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E535" b2="138 KV" b3="5-8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="E535" b2="138 KV" b3="TR72" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103279</SeqNum>
    <Name>L138.Hoffman-21401-Schaumburg.21401</Name>
    <LastEdit Timestamp="2026-02-09T10:25:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="214 HOFF" b2="138 KV" b3="21401_1" />
      <ContingencyEquipment Action="L" Type="LN" b1="21401" b2="138 KV" b3="21401-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="21401" b2="138 KV" b3="21401_2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="220 S SC" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="220 S SC" b2="138 KV" b3="L21401CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="253 SCHA" b2="138 KV" b3="18411CS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="253 SCHA" b2="138 KV" b3="L21401CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103280</SeqNum>
    <Name>L138.Hoffman-21404-Schaumburg.21404</Name>
    <LastEdit Timestamp="2026-05-08T14:19:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="13-14" />
      <ContingencyEquipment Action="L" Type="LN" b1="214 HOFF" b2="138 KV" b3="21404_1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="214 HOFF" b2="138 KV" b3="9-14" />
      <ContingencyEquipment Action="L" Type="LN" b1="21404" b2="138 KV" b3="21404-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="21404" b2="138 KV" b3="21404_2" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="220 S SC" b2="138 KV" b3="BT2-3 CS" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="253 SCHA" b2="138 KV" b3="18410CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103281</SeqNum>
    <Name>L345.Fairbanks-Dresser (External)</Name>
    <LastEdit Timestamp="2024-12-18T10:01:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DRESSER" b2="345 KV" b3="20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRBNKS" b2="345 KV" b3="50-20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRBNKS" b2="345 KV" b3="51-20" />
      <ContingencyEquipment Action="L" Type="LN" b1="DRESSER" b2="345 KV" b3="DRE-FAIR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103282</SeqNum>
    <Name>L345.Fairbanks-Merom_HE (External)</Name>
    <LastEdit Timestamp="2024-12-18T10:02:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRBNKS" b2="345 KV" b3="50-20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FAIRBNKS" b2="345 KV" b3="51-20" />
      <ContingencyEquipment Action="L" Type="LN" b1="FAIRBNKS" b2="345 KV" b3="FAI-MERO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEROM_HE" b2="345 KV" b3="3822" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEROM_HE" b2="345 KV" b3="388" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103284</SeqNum>
    <Name>L138.Philo-Chandler-Bridge-Bloom-Bethel-WDover</Name>
    <LastEdit Timestamp="2024-12-19T09:37:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BLOOMFSW" b2="138 KV" b3="BLO-BRI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLOOMFSW" b2="138 KV" b3="BLO-GMB1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WDOVER" b2="138 KV" b3="WDO-BLO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRIDGEV2" b2="138 KV" b3="BRI-GMC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRIDGEV2" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GMBETHEL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GMCHANDL" b2="138 KV" b3="GMC-PHI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GMCHANDL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PHILO" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WDOVER" b2="138 KV" b3="H000B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WDOVER" b2="138 KV" b3="H000B8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103285</SeqNum>
    <Name>L138.WDover-Strasburg-NStrasburg-SCanton</Name>
    <LastEdit Timestamp="2024-12-18T11:26:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="NSTRASBU" b2="138 KV" b3="NST-STR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NSTRASBU" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCANTON2" b2="138 KV" b3="M2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCANTON2" b2="138 KV" b3="SCA-NST1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STRABURG" b2="138 KV" b3="STR-WDO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STRABURG" b2="138 KV" b3="T1LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WDOVER" b2="138 KV" b3="H000K5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WDOVER" b2="138 KV" b3="H000K8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103286</SeqNum>
    <Name>138/69.WDover.T1</Name>
    <LastEdit Timestamp="2025-06-12T11:19:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WDOVER" b2="138 KV" b3="H000B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WDOVER" b2="138 KV" b3="H000K8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WDOVER" b2="69 KV" b3="H006Z5CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="WDOVER" b2="138 KV" b3="T1_XF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103287</SeqNum>
    <Name>L138.WDover-SugarCreekTerminal</Name>
    <LastEdit Timestamp="2024-12-18T11:33:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUGARCRT" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WDOVER" b2="138 KV" b3="H000B8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WDOVER" b2="138 KV" b3="H000K5" />
      <ContingencyEquipment Action="L" Type="LN" b1="SUGARCRT" b2="138 KV" b3="SUG-WDOV" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103288</SeqNum>
    <Name>L138.Modoc-Wapahani</Name>
    <LastEdit Timestamp="2024-12-18T11:40:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MODOC" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MODOC" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MODOC" b2="138 KV" b3="MOD-WAPA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAPAHANI" b2="138 KV" b3="M005B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAPAHANI" b2="138 KV" b3="M005B8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103289</SeqNum>
    <Name>L138.Wapahani-Desoto</Name>
    <LastEdit Timestamp="2024-12-18T11:41:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESOTO" b2="138 KV" b3="M1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DESOTO" b2="138 KV" b3="DES-WAPA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAPAHANI" b2="138 KV" b3="M005B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAPAHANI" b2="138 KV" b3="M005B8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103290</SeqNum>
    <Name>L230.MtVernon-Harvard.23141</Name>
    <LastEdit Timestamp="2024-12-18T11:45:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVARD" b2="230 KV" b3="1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVARD" b2="230 KV" b3="1B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTVERPEP" b2="230 KV" b3="1A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTVERPEP" b2="230 KV" b3="1B" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARVARD" b2="230 KV" b3="HAR-MTV1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103291</SeqNum>
    <Name>DTX138.Hill.BK2</Name>
    <LastEdit Timestamp="2024-12-18T16:23:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILL" b2="115 KV" b3="2 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILL" b2="115 KV" b3="B18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILL" b2="115 KV" b3="B19" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103292</SeqNum>
    <Name>DTX138.Hill.BK3</Name>
    <LastEdit Timestamp="2024-12-18T16:24:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILL" b2="115 KV" b3="3 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILL" b2="115 KV" b3="B17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HILL" b2="115 KV" b3="B20" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103294</SeqNum>
    <Name>L138.Springdale-Plum.Z-54</Name>
    <LastEdit Timestamp="2024-12-19T12:42:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLUM" b2="138 KV" b3="CHES54" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPRINGDA" b2="138 KV" b3="B23" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLUM" b2="138 KV" b3="PLU-SPRI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103295</SeqNum>
    <Name>L69.Sunbury-Penns-HummelsW-SellingsGrove.C</Name>
    <LastEdit Timestamp="2025-08-22T10:29:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HUMMELSW" b2="69 KV" b3="HUM-SELI" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUMMELSW" b2="69 KV" b3="HUM-SETP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HUMMELSW" b2="69 KV" b3="HUWH_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="PENNS" b2="69 KV" b3="PEN-SETP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PENNS" b2="69 KV" b3="PENNS_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PENNS" b2="69 KV" b3="PENN_CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PENNS" b2="69 KV" b3="PENN_SP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SELINGRV" b2="69 KV" b3="4033" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SELINGRV" b2="69 KV" b3="SELI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="COLU1PEN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUNBURY" b2="69 KV" b3="PENNS" />
      <ContingencyEquipment Action="L" Type="LN" b1="SETP" b2="69 KV" b3="SET-SUN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103297</SeqNum>
    <Name>L138.Wentworth-Eber</Name>
    <LastEdit Timestamp="2025-03-13T09:33:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02EBER" b2="138 KV" b3="B13435" />
      <ContingencyEquipment Action="L" Type="LN" b1="02EBER" b2="138 KV" b3="02E-02W1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02WENTWT" b2="138 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02WENTWT" b2="138 KV" b3="B27" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103298</SeqNum>
    <Name>DTX138.Sifford.Ruble2A </Name>
    <LastEdit Timestamp="2025-01-09T18:05:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SIFFORD" b2="138 KV" b3="H024K5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIFFORD" b2="138 KV" b3="H024K8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SIFFORD" b2="138 KV" b3="RUBLE2A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103299</SeqNum>
    <Name>DTX138.Sifford.Ruble2B </Name>
    <LastEdit Timestamp="2025-01-09T18:05:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SIFFORD" b2="138 KV" b3="H024L5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIFFORD" b2="138 KV" b3="H024L8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SIFFORD" b2="138 KV" b3="RUBLE2B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103300</SeqNum>
    <Name>DTX138.Sifford.Ruble1A</Name>
    <LastEdit Timestamp="2024-12-30T09:16:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SIFFORD" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIFFORD" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SIFFORD" b2="138 KV" b3="RUBLE1A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103301</SeqNum>
    <Name>DTX138.Sifford.Ruble1B</Name>
    <LastEdit Timestamp="2024-12-30T09:16:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SIFFORD" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIFFORD" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SIFFORD" b2="138 KV" b3="RUBLE1B" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103302</SeqNum>
    <Name>L138.Clifford-Colleen-JamesRiver</Name>
    <LastEdit Timestamp="2026-06-01T12:05:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CLIFFORD" b2="138 KV" b3="CLI-COL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLIFFORD" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COLLEEN" b2="138 KV" b3="LOAD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COLLEEN" b2="138 KV" b3="LOAD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JAMESRV" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLLEEN" b2="138 KV" b3="COL-JAME" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103304</SeqNum>
    <Name>L345.Larrison-Dumont.2</Name>
    <LastEdit Timestamp="2025-10-16T15:23:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DUMONT2" b2="345 KV" b3="DUM-LAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="345 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="345 KV" b3="G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M007Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M007Z5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103306</SeqNum>
    <Name>L345.Larrison-Sorenson</Name>
    <LastEdit Timestamp="2024-12-31T13:30:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LARRISON" b2="345 KV" b3="LAR-SORE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008E2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008E5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="345 KV" b3="E2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103307</SeqNum>
    <Name>DTX345.Larrison.1</Name>
    <LastEdit Timestamp="2024-12-31T13:31:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LARRISON" b2="345 KV" b3="LOAD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M007Z5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M007Z8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103308</SeqNum>
    <Name>DTX345.Larrison.2</Name>
    <LastEdit Timestamp="2024-12-31T13:32:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LARRISON" b2="345 KV" b3="LOAD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008A5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008A8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103309</SeqNum>
    <Name>DTX345.Larrison.3</Name>
    <LastEdit Timestamp="2025-05-28T10:45:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LARRISON" b2="345 KV" b3="LOAD3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008B5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103310</SeqNum>
    <Name>DTX345.Larrison.4</Name>
    <LastEdit Timestamp="2025-04-15T15:12:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LARRISON" b2="345 KV" b3="LOAD4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008C5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103311</SeqNum>
    <Name>DTX345.Larrison.5</Name>
    <LastEdit Timestamp="2025-08-28T16:15:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LARRISON" b2="345 KV" b3="LOAD5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008D5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008D8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103312</SeqNum>
    <Name>DTX345.Larrison.6</Name>
    <LastEdit Timestamp="2025-08-28T16:15:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LARRISON" b2="345 KV" b3="LOAD6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008E5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008E8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103313</SeqNum>
    <Name>138/69.Master.T2</Name>
    <LastEdit Timestamp="2024-12-31T13:41:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MASTER" b2="69 KV" b3="165 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASTER" b2="138 KV" b3="25 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="MASTER" b2="138 KV" b3="MAS 2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103314</SeqNum>
    <Name>DTX345.Beacon.Darby1</Name>
    <LastEdit Timestamp="2024-12-31T13:57:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEACON" b2="345 KV" b3="DARBY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEACON" b2="345 KV" b3="H007R2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEACON" b2="345 KV" b3="H007R5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103315</SeqNum>
    <Name>DTX345.Beacon.Darby2</Name>
    <LastEdit Timestamp="2024-12-31T13:58:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEACON" b2="345 KV" b3="DARBY2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEACON" b2="345 KV" b3="H007Q2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEACON" b2="345 KV" b3="H007Q5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103316</SeqNum>
    <Name>DTX345.Beacon.Darby3</Name>
    <LastEdit Timestamp="2024-12-31T14:01:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BEACON" b2="345 KV" b3="DARBY3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEACON" b2="345 KV" b3="H007P2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEACON" b2="345 KV" b3="H007P5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103317</SeqNum>
    <Name>DTX115.Werner.BK12</Name>
    <LastEdit Timestamp="2024-12-31T14:41:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WERNER" b2="115 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WERNER" b2="115 KV" b3="B21" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WERNER" b2="115 KV" b3="BK 12" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103318</SeqNum>
    <Name>DTX115.Werner.TR14</Name>
    <LastEdit Timestamp="2024-12-31T14:41:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WERNER" b2="115 KV" b3="B19" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WERNER" b2="115 KV" b3="B22" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WERNER" b2="115 KV" b3="TR14LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103319</SeqNum>
    <Name>L138.NorthNewark-MountPerry-Isabella-Crooksville</Name>
    <LastEdit Timestamp="2024-12-31T14:47:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CROOKSVI" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="CROOKSVI" b2="138 KV" b3="CRO-ISAB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ISABELLA" b2="138 KV" b3="ISA-MOUN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ISABELLA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOUNTPER" b2="138 KV" b3="MOU-NNEW" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MOUNTPER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NNEWARK" b2="138 KV" b3="H000Z8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103321</SeqNum>
    <Name>L138.Shelby-Franklin</Name>
    <LastEdit Timestamp="2025-01-06T16:18:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLI5" b2="138 KV" b3="BN-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLI5" b2="138 KV" b3="BN-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBY" b2="138 KV" b3="F" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKLI5" b2="138 KV" b3="FRA-SHEL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103322</SeqNum>
    <Name>DTX138.Franklin.Honda1</Name>
    <LastEdit Timestamp="2025-01-06T16:30:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLI5" b2="138 KV" b3="BN-A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLI5" b2="138 KV" b3="BN-B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRANKLI5" b2="138 KV" b3="HONDA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103323</SeqNum>
    <Name>DTX138.Franklin.Honda2</Name>
    <LastEdit Timestamp="2025-01-06T16:31:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLI5" b2="138 KV" b3="BN-D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLI5" b2="138 KV" b3="BN-E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRANKLI5" b2="138 KV" b3="HONDA2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103325</SeqNum>
    <Name>230/115.Trowbridge.TX1</Name>
    <LastEdit Timestamp="2025-01-09T11:36:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="230 KV" b3="H1T2126" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="115 KV" b3="L1T167" />
      <ContingencyEquipment Action="X" Type="XF" b1="TROWBRDG" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103326</SeqNum>
    <Name>230/115.Trowbridge.TX2</Name>
    <LastEdit Timestamp="2025-01-09T11:37:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="230 KV" b3="H2T2034" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TROWBRDG" b2="115 KV" b3="L2T168" />
      <ContingencyEquipment Action="X" Type="XF" b1="TROWBRDG" b2="230 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103337</SeqNum>
    <Name>L345.Dumont-NewPrairie</Name>
    <LastEdit Timestamp="2026-02-10T10:29:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DUMONT2" b2="345 KV" b3="DUM-NPRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="345 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="345 KV" b3="G2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPRAIRIE" b2="345 KV" b3="M008L2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPRAIRIE" b2="345 KV" b3="M008L5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103339</SeqNum>
    <Name>L138.LuseRoad-Monticello</Name>
    <LastEdit Timestamp="2025-08-22T08:19:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="17MONTCL" b2="138 KV" b3="125E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="17MONTCL" b2="138 KV" b3="125W" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUSE_RD" b2="138 KV" b3="125E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUSE_RD" b2="138 KV" b3="125W" />
      <ContingencyEquipment Action="L" Type="LN" b1="LUSE_RD" b2="138 KV" b3="LUS-MONT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103342</SeqNum>
    <Name>L500.BrownsFerry-Madison (TVA)</Name>
    <LastEdit Timestamp="2025-01-24T11:57:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BFNP" b2="500 KV" b3="32227A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BFNP" b2="500 KV" b3="5224" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BFNP" b2="500 KV" b3="5228" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MADISNTV" b2="500 KV" b3="5024" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MADISNTV" b2="500 KV" b3="5027" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103343</SeqNum>
    <Name>Spickard.SP</Name>
    <LastEdit Timestamp="2025-01-29T15:44:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="SPICKARD" b2="34.5 KV" b3="DODSONSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="SPICKARD" b2="138 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SPICKARD" b2="138 KV" b3="GSUCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103349</SeqNum>
    <Name>230/115.CannonBranch.TX1</Name>
    <LastEdit Timestamp="2025-01-29T15:18:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CANNONBR" b2="230 KV" b3="H122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANNONBR" b2="230 KV" b3="H1T2195" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANNONBR" b2="115 KV" b3="L1T197" />
      <ContingencyEquipment Action="X" Type="XF" b1="CANNONBR" b2="230 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103351</SeqNum>
    <Name>L138.Hiple-Northport (NIPS)</Name>
    <LastEdit Timestamp="2025-01-31T08:58:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="138 KV" b3="123-00" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HIPLE" b2="138 KV" b3="138-123" />
      <ContingencyEquipment Action="L" Type="LN" b1="HIPLE" b2="138 KV" b3="HIP-NORT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHPOR" b2="138 KV" b3="123_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHPOR" b2="138 KV" b3="123_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103353</SeqNum>
    <Name>DTX138.Brie.Voltron1</Name>
    <LastEdit Timestamp="2025-02-18T12:38:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H002V2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H002V5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRIE" b2="138 KV" b3="VOLTRON1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103354</SeqNum>
    <Name>DTX138.Brie.Voltron2</Name>
    <LastEdit Timestamp="2025-02-18T12:38:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H002W2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H002W5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRIE" b2="138 KV" b3="VOLTRON2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103355</SeqNum>
    <Name>DTX138.Brie.Voltron3</Name>
    <LastEdit Timestamp="2025-02-18T12:40:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H002Y2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H002Y5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRIE" b2="138 KV" b3="VOLTRON3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103356</SeqNum>
    <Name>DTX138.Brie.Voltron4</Name>
    <LastEdit Timestamp="2025-02-18T12:41:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H020H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H020H5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BRIE" b2="138 KV" b3="VOLTRON4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103358</SeqNum>
    <Name>L138.FudgeHollow-KanawhaTr-Greenbri</Name>
    <LastEdit Timestamp="2025-02-04T07:09:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FUDGEHO4" b2="138 KV" b3="14A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FUDGEHO4" b2="138 KV" b3="14T112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FUDGEHO4" b2="138 KV" b3="14T155" />
      <ContingencyEquipment Action="L" Type="LN" b1="KANAWTRL" b2="138 KV" b3="KAN-GRE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KANAWTRL" b2="46 KV" b3="LOAD" />
      <ContingencyEquipment Action="X" Type="XF" b1="KANAWTRL" b2="138 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103359</SeqNum>
    <Name>L138.Hinton-Roncvr-Greenbri</Name>
    <LastEdit Timestamp="2025-02-04T07:32:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="GREENBRI" b2="138 KV" b3="CAPB" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENBRI" b2="138 KV" b3="GRE-RON1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENBRI" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENBRI" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HINTON" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="HINTON" b2="138 KV" b3="HIN-RON1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RONCEVER" b2="138 KV" b3="T1T3T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103360</SeqNum>
    <Name>L138.Poth-Yearling</Name>
    <LastEdit Timestamp="2025-05-12T15:54:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POTH" b2="138 KV" b3="H010V2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTH" b2="138 KV" b3="H010X8" />
      <ContingencyEquipment Action="L" Type="LN" b1="POTH" b2="138 KV" b3="POT-YEAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YEARLING" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="YEARLING" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103361</SeqNum>
    <Name>DTX138.Poth.T1</Name>
    <LastEdit Timestamp="2025-05-12T15:55:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POTH" b2="138 KV" b3="H010X5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTH" b2="138 KV" b3="H010X8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POTH" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103362</SeqNum>
    <Name>DTX138.Poth.T2</Name>
    <LastEdit Timestamp="2025-05-12T15:55:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="POTH" b2="138 KV" b3="H010V2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POTH" b2="138 KV" b3="H010X2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POTH" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103364</SeqNum>
    <Name>DTX230.Altair.Y74 Load</Name>
    <LastEdit Timestamp="2025-02-05T09:47:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAIR" b2="230 KV" b3="20172-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAIR" b2="230 KV" b3="226372-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALTAIR" b2="230 KV" b3="LD2_Y74" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103365</SeqNum>
    <Name>DTX230.Altair.W74 Load</Name>
    <LastEdit Timestamp="2025-02-05T09:49:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAIR" b2="230 KV" b3="20172-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALTAIR" b2="230 KV" b3="226372-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALTAIR" b2="230 KV" b3="LD1_W74" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103366</SeqNum>
    <Name>L138.OhioCentral-Newcomer</Name>
    <LastEdit Timestamp="2025-12-19T16:36:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCOMER" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OHIOCENT" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="OHIOCENT" b2="138 KV" b3="OHI-SCO1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SCOSHOCT" b2="138 KV" b3="DUME1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCOSHOCT" b2="138 KV" b3="MOBOP112" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWCOMER" b2="138 KV" b3="NEW-SCO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103368</SeqNum>
    <Name>L115.Jeffress-Clarksville-BurlDrTp-BuggsIsland.36</Name>
    <LastEdit Timestamp="2025-02-21T15:05:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUGGSISL" b2="115 KV" b3="3612" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURDRTP" b2="115 KV" b3="36D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUGGSISL" b2="115 KV" b3="36T127" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BURDRTP" b2="115 KV" b3="3637" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BURDRTP" b2="115 KV" b3="3637-1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BURDRTP" b2="115 KV" b3="36E" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="BURDRTP" b2="115 KV" b3="36T193" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLARKVIL" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLARKVIL" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFRESS" b2="115 KV" b3="3652" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLARKVIL" b2="115 KV" b3="CLA-JEFF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFRESS" b2="115 KV" b3="VT36" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103369</SeqNum>
    <Name>DTX115.Jeffress.115kV LOAD W37</Name>
    <LastEdit Timestamp="2025-02-11T11:34:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JEFFRESS" b2="115 KV" b3="LD_W37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFRESS" b2="115 KV" b3="W52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFRESS" b2="115 KV" b3="WT1058" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103370</SeqNum>
    <Name>DTX115.Jeffress.115kV LOAD V37</Name>
    <LastEdit Timestamp="2025-02-11T11:36:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JEFFRESS" b2="115 KV" b3="LD_V37" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFRESS" b2="115 KV" b3="V52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEFFRESS" b2="115 KV" b3="VT36" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103376</SeqNum>
    <Name>L138.Calumet-Sheffield (NIPS)</Name>
    <LastEdit Timestamp="2025-02-14T08:27:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CALUMETP" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALUMETP" b2="34 KV" b3="34 XFR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CALUMETP" b2="138 KV" b3="38BT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="138 KV" b3="478" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHEFFILD" b2="138 KV" b3="SHE-CAL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHEFFILD" b2="138 KV" b3="X204" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103377</SeqNum>
    <Name>L138.Watson-Forbes.Z-85</Name>
    <LastEdit Timestamp="2025-05-13T10:48:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FORBES" b2="138 KV" b3="TIE 14" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FORBES" b2="138 KV" b3="TIE 42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATSON2" b2="138 KV" b3="TIE1-8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATSON2" b2="138 KV" b3="TIE6-7" />
      <ContingencyEquipment Action="L" Type="LN" b1="FORBES" b2="138 KV" b3="WAT-FOR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103378</SeqNum>
    <Name>DTX138.Anguin.DEVITO2</Name>
    <LastEdit Timestamp="2026-05-08T14:47:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ANGUIN" b2="138 KV" b3="DEVITO2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="H022U5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ANGUIN" b2="138 KV" b3="H022U8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103381</SeqNum>
    <Name>L138.Innovation-GreenChapel.1</Name>
    <LastEdit Timestamp="2025-11-17T15:28:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008J2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008J5" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENCHA" b2="138 KV" b3="GRE-INN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H009C5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H009C8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103382</SeqNum>
    <Name>L138.Innovation-GreenChapel.2</Name>
    <LastEdit Timestamp="2025-11-17T15:28:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008H5" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENCHA" b2="138 KV" b3="GRE-INN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H009B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H009B8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103383</SeqNum>
    <Name>115/34.5.NorthMeshoppen.BK1</Name>
    <LastEdit Timestamp="2025-02-24T09:43:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="115 KV" b3="B100" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="115 KV" b3="B101" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NMESHOPP" b2="34.5 KV" b3="B5" />
      <ContingencyEquipment Action="X" Type="XF" b1="NMESHOPP" b2="115 KV" b3="BK1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103384</SeqNum>
    <Name>L161.Paradise-ParadiseCC.1 (TVA)</Name>
    <LastEdit Timestamp="2025-02-24T11:37:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="5PARADCC" b2="161 KV" b3="1214" />
      <ContingencyEquipment Action="OP" Type="CB" b1="5PARADCC" b2="161 KV" b3="1224" />
      <ContingencyEquipment Action="L" Type="LN" b1="5PARADCC" b2="161 KV" b3="PARA-PAR" />
      <ContingencyEquipment Action="U" Type="GEN" b1="5PARADCC" b2="18 KV" b3="PARADCC1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="5PARADCC" b2="18 KV" b3="PARADCC2" />
      <ContingencyEquipment Action="X" Type="XF" b1="5PARADCC" b2="161 KV" b3="XF1" />
      <ContingencyEquipment Action="X" Type="XF" b1="5PARADCC" b2="161 KV" b3="XF2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARADIS" b2="161 KV" b3="864" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARADIS" b2="161 KV" b3="868" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103385</SeqNum>
    <Name>L161.Paradise-ParadiseCC.2 (TVA)</Name>
    <LastEdit Timestamp="2025-07-16T12:30:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="5PARADCC" b2="161 KV" b3="1234" />
      <ContingencyEquipment Action="OP" Type="CB" b1="5PARADCC" b2="161 KV" b3="1244" />
      <ContingencyEquipment Action="U" Type="GEN" b1="5PARADCC" b2="18 KV" b3="PARADCC3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="5PARADCC" b2="18 KV" b3="PARADST1" />
      <ContingencyEquipment Action="L" Type="LN" b1="5PARADCC" b2="161 KV" b3="PCC-5PA2" />
      <ContingencyEquipment Action="X" Type="XF" b1="5PARADCC" b2="161 KV" b3="XF3" />
      <ContingencyEquipment Action="X" Type="XF" b1="5PARADCC" b2="161 KV" b3="XF4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="5PARADIS" b2="161 KV" b3="1056" />
      <ContingencyEquipment Action="OP" Type="CB" b1="5PARADIS" b2="161 KV" b3="958" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103401</SeqNum>
    <Name>230/34.Frederick.TR5</Name>
    <LastEdit Timestamp="2025-03-10T14:33:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FREDERIC" b2="230 KV" b3="T5CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FREDERIC" b2="34.5 KV" b3="T5LCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="FREDERIC" b2="230 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103402</SeqNum>
    <Name>L138.SouthOttawa-Ottawa (IP/MISO)</Name>
    <LastEdit Timestamp="2025-03-10T14:51:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OTTAWAIP" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOTTAWA" b2="138 KV" b3="H5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOTTAWA" b2="138 KV" b3="H7" />
      <ContingencyEquipment Action="L" Type="LN" b1="OTTAWAIP" b2="138 KV" b3="OTTI-SOT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103407</SeqNum>
    <Name>DTX138.JugStreet.XT1</Name>
    <LastEdit Timestamp="2025-03-20T16:35:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUGSTRET" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JUGSTRET" b2="138 KV" b3="LD-XF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103408</SeqNum>
    <Name>L115.RidgeRoad-Bishop.1080A</Name>
    <LastEdit Timestamp="2025-03-20T10:43:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP2" b2="115 KV" b3="108012" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP2" b2="115 KV" b3="WT1080" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGROAD" b2="115 KV" b3="108072" />
      <ContingencyEquipment Action="L" Type="LN" b1="BISHOP2" b2="115 KV" b3="BIS-RIDG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGROAD" b2="115 KV" b3="YT1080" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103409</SeqNum>
    <Name>DTX115.Bishop.LDV17</Name>
    <LastEdit Timestamp="2025-03-20T10:44:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BISHOP2" b2="115 KV" b3="LD_V17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP2" b2="115 KV" b3="V12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP2" b2="115 KV" b3="VT137" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103410</SeqNum>
    <Name>DTX115.Bishop.LDW17</Name>
    <LastEdit Timestamp="2025-03-20T10:44:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BISHOP2" b2="115 KV" b3="LD_W17" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP2" b2="115 KV" b3="W12" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISHOP2" b2="115 KV" b3="WT1080" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103412</SeqNum>
    <Name>DTX138.Cyprus.Feathe</Name>
    <LastEdit Timestamp="2025-03-23T17:58:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CYPRUS" b2="138 KV" b3="FEATHE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H017Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H017Z5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103413</SeqNum>
    <Name>DTX138.Mink.T2</Name>
    <LastEdit Timestamp="2025-03-23T17:58:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MINK" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINK" b2="138 KV" b3="H014Q2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MINK" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103414</SeqNum>
    <Name>L138.Tangy-Bellepoint (Sctnlz) </Name>
    <LastEdit Timestamp="2025-03-24T09:38:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELLEP" b2="138 KV" b3="A627" />
      <ContingencyEquipment Action="L" Type="LN" b1="TANGY" b2="138 KV" b3="TAN-BEL1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="TANGY" b2="138 KV" b3="A157" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANGY" b2="138 KV" b3="B155" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103415</SeqNum>
    <Name>L138.Bellepoint-MillCreek-Finley (Sctnlz)</Name>
    <LastEdit Timestamp="2025-03-24T09:39:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BELLEP" b2="138 KV" b3="BEL-02M1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02MLCRK" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FINLEY" b2="138 KV" b3="FIN-MIL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02MLCRK" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELLEP" b2="138 KV" b3="A631" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINLEY" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINLEY" b2="138 KV" b3="B3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103416</SeqNum>
    <Name>L345.Joachim-Tyson</Name>
    <LastEdit Timestamp="2025-03-24T10:04:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JOACHIM" b2="345 KV" b3="JOA-TYS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JOACHIM" b2="345 KV" b3="V5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TYSON  3" b2="345 KV" b3="JOCM 2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103417</SeqNum>
    <Name>L138.Cincinatti-Towerline</Name>
    <LastEdit Timestamp="2025-03-24T10:17:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CINCNATI" b2="138 KV" b3="CIN-TWRL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CINCNATI" b2="138 KV" b3="H3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CINCNATI" b2="138 KV" b3="H5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWRL" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWRL" b2="138 KV" b3="H11" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103418</SeqNum>
    <Name>L138.ToldeoHospital-Bellevue (Sctnlz)</Name>
    <LastEdit Timestamp="2026-02-10T13:10:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELLEVUE" b2="138 KV" b3="B26_DIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="TOLEDOHP" b2="138 KV" b3="TOL-BEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOLEDOHP" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOLEDOHP" b2="138 KV" b3="B4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103419</SeqNum>
    <Name>L138.Bellevue-UniversityOT-Vulcan (Sctnlz)</Name>
    <LastEdit Timestamp="2026-02-10T13:11:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELLEVUE" b2="138 KV" b3="B27_DIS" />
      <ContingencyEquipment Action="L" Type="LN" b1="UNIV_TOL" b2="138 KV" b3="02U-BEL1" />
      <ContingencyEquipment Action="L" Type="LN" b1="UNIV_TOL" b2="138 KV" b3="02U-VUL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="UNIV_TOL" b2="138 KV" b3="3381" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIV_TOL" b2="138 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VULCAN" b2="138 KV" b3="B13395" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103420</SeqNum>
    <Name>L115.Newberry-Cly (Sctnlz)</Name>
    <LastEdit Timestamp="2026-03-17T07:04:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLY" b2="115 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLY" b2="115 KV" b3="B39" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWBERRY" b2="115 KV" b3="97586" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLY" b2="115 KV" b3="CLY-NEW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103421</SeqNum>
    <Name>L115.RoundTop-Newberry (Sctnlz)</Name>
    <LastEdit Timestamp="2025-03-24T10:34:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWBERRY" b2="115 KV" b3="97589" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWBERRY" b2="115 KV" b3="NEW-ROU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROUNDTOP" b2="115 KV" b3="B97572" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103423</SeqNum>
    <Name>L115.MiddletownJct-Collins (Sctnlz)</Name>
    <LastEdit Timestamp="2025-03-24T11:15:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLINS" b2="115 KV" b3="97576" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLLINS" b2="115 KV" b3="COL-MID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDDLJCT" b2="115 KV" b3="B97542" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103424</SeqNum>
    <Name>L115.Collins-Cly (Sctnlz)</Name>
    <LastEdit Timestamp="2025-03-24T11:15:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLY" b2="115 KV" b3="B39" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLY" b2="115 KV" b3="B47" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLY" b2="115 KV" b3="CLY-COL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLLINS" b2="115 KV" b3="97579" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103427</SeqNum>
    <Name>500/230.HopeCreek.500-1</Name>
    <LastEdit Timestamp="2025-05-14T09:34:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="1-7" />
      <ContingencyEquipment Action="X" Type="XF" b1="HOPECREE" b2="500 KV" b3="500-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="230 KV" b3="500-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="500 KV" b3="7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103428</SeqNum>
    <Name>L230.HopeCreek-SilverRun</Name>
    <LastEdit Timestamp="2025-05-14T09:34:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOPECREE" b2="230 KV" b3="500-1CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERUN" b2="230 KV" b3="F110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SILVERUN" b2="230 KV" b3="F120" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOPECREE" b2="230 KV" b3="HOP-SIL" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103430</SeqNum>
    <Name>DTX138.Marion.T8</Name>
    <LastEdit Timestamp="2025-03-25T12:10:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="H015B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="H015B5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARION2" b2="138 KV" b3="T8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103431</SeqNum>
    <Name>DTX138.McKinley.T4</Name>
    <LastEdit Timestamp="2025-04-21T09:35:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MCKINLEY" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCKINLEY" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCKINLEY" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCKINLEY" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103434</SeqNum>
    <Name>L500.Davidson-Johnsonville (TVA)</Name>
    <LastEdit Timestamp="2025-03-31T06:36:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DAVIDSO" b2="500 KV" b3="5034" />
      <ContingencyEquipment Action="L" Type="LN" b1="JVILLE" b2="500 KV" b3="32221A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JVILLE" b2="500 KV" b3="5084" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103437</SeqNum>
    <Name>DTX138.Wentworth.TR1</Name>
    <LastEdit Timestamp="2025-06-12T11:58:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02WENTWT" b2="138 KV" b3="B26" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02WENTWT" b2="138 KV" b3="B30" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02WENTWT" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103438</SeqNum>
    <Name>DTX138.Wentworth.TR2</Name>
    <LastEdit Timestamp="2025-06-12T11:59:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02WENTWT" b2="138 KV" b3="B27" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02WENTWT" b2="138 KV" b3="B28" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02WENTWT" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103440</SeqNum>
    <Name>138/34.79Spaulding.TR76</Name>
    <LastEdit Timestamp="2025-05-02T15:30:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="79 SPAUL" b2="138 KV" b3="TR76 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="34.5 KV" b3="TR76 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="79 SPAUL" b2="138 KV" b3="TR76 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103441</SeqNum>
    <Name>138/34.79Spaulding.TR77</Name>
    <LastEdit Timestamp="2025-05-02T15:27:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="79 SPAUL" b2="138 KV" b3="TR77 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="34.5 KV" b3="TR77 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="79 SPAUL" b2="138 KV" b3="TR77 CS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103442</SeqNum>
    <Name>138/34.79Spaulding.TR78</Name>
    <LastEdit Timestamp="2025-05-02T15:07:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="79 SPAUL" b2="138 KV" b3="TR78 34" />
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="34.5 KV" b3="TR78 CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="79 SPAUL" b2="138 KV" b3="TR78 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103449</SeqNum>
    <Name>230/35.Clay.T1</Name>
    <LastEdit Timestamp="2025-04-02T15:25:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAY PE" b2="35 KV" b3="110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAY PE" b2="230 KV" b3="715" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLAY PE" b2="230 KV" b3="CLAY1TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103450</SeqNum>
    <Name>230/35.Clay.T2</Name>
    <LastEdit Timestamp="2025-04-02T15:26:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAY PE" b2="35 KV" b3="120 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLAY PE" b2="230 KV" b3="825" />
      <ContingencyEquipment Action="X" Type="XF" b1="CLAY PE" b2="230 KV" b3="CLAY2TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103453</SeqNum>
    <Name>DTX230.Northstar.W64</Name>
    <LastEdit Timestamp="2025-04-07T11:22:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHSTAR" b2="230 KV" b3="204562-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHSTAR" b2="230 KV" b3="231962-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NRTHSTAR" b2="230 KV" b3="W64_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103454</SeqNum>
    <Name>DTX230.Northstar.Y64</Name>
    <LastEdit Timestamp="2025-04-07T11:24:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHSTAR" b2="230 KV" b3="204562-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHSTAR" b2="230 KV" b3="231962-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NRTHSTAR" b2="230 KV" b3="Y64_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103455</SeqNum>
    <Name>DTX138.Talmadge.TR2</Name>
    <LastEdit Timestamp="2025-04-07T11:42:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="TALWGATE" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TALWGATE" b2="138 KV" b3="B50" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TALWGATE" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103456</SeqNum>
    <Name>DTX138.Jerome.C2</Name>
    <LastEdit Timestamp="2025-04-07T12:24:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JEROMEOH" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEROMEOH" b2="138 KV" b3="H010C5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEROMEOH" b2="138 KV" b3="H010C8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103458</SeqNum>
    <Name>DTX138.Angola.TR2</Name>
    <LastEdit Timestamp="2025-04-08T10:57:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02ANGOLA" b2="138 KV" b3="B13471" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02ANGOLA" b2="138 KV" b3="B13473" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02ANGOLA" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103459</SeqNum>
    <Name>L138.Marion.52AB</Name>
    <LastEdit Timestamp="2025-04-08T11:07:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="H015D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="H024T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103463</SeqNum>
    <Name>DTX138.Hockessin.T4</Name>
    <LastEdit Timestamp="2025-04-10T15:24:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOCKESIN" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOCKESIN" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOCKESIN" b2="138 KV" b3="T4 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103464</SeqNum>
    <Name>DTX138.Hockessin.T5</Name>
    <LastEdit Timestamp="2025-04-10T15:25:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOCKESIN" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOCKESIN" b2="138 KV" b3="133" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HOCKESIN" b2="138 KV" b3="T5 LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103465</SeqNum>
    <Name>DTX69.DarleyRoad.T1</Name>
    <LastEdit Timestamp="2025-04-10T15:26:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARLEYRD" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARLEYRD" b2="69 KV" b3="68" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DARLEYRD" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103466</SeqNum>
    <Name>DTX69.DarleyRoad.T2</Name>
    <LastEdit Timestamp="2025-04-11T17:43:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARLEYRD" b2="69 KV" b3="66" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARLEYRD" b2="69 KV" b3="68" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DARLEYRD" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103467</SeqNum>
    <Name>DTX69.DarleyRoad.T3</Name>
    <LastEdit Timestamp="2025-04-10T15:27:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DARLEYRD" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DARLEYRD" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DARLEYRD" b2="69 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103468</SeqNum>
    <Name>DTX69.Kenney.T1</Name>
    <LastEdit Timestamp="2025-04-10T15:30:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNEY" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNEY" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KENNEY" b2="24 KV" b3="T1" />
      <ContingencyEquipment Action="X" Type="XF" b1="KENNEY" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103469</SeqNum>
    <Name>DTX69.Kenney.T2</Name>
    <LastEdit Timestamp="2025-04-10T15:31:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNEY" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENNEY" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KENNEY" b2="24 KV" b3="T2" />
      <ContingencyEquipment Action="X" Type="XF" b1="KENNEY" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103470</SeqNum>
    <Name>DTX69.MountHermon.T1</Name>
    <LastEdit Timestamp="2025-04-10T15:33:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MTHERMON" b2="69 KV" b3="7580" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTHERMON" b2="69 KV" b3="7590" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTHERMON" b2="69 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103471</SeqNum>
    <Name>DTX69.MountHermon.T2</Name>
    <LastEdit Timestamp="2025-04-10T15:34:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MTHERMON" b2="69 KV" b3="7570" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTHERMON" b2="69 KV" b3="7580" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTHERMON" b2="69 KV" b3="LOADT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103472</SeqNum>
    <Name>DTX69.Naamans.T1</Name>
    <LastEdit Timestamp="2025-04-10T15:34:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NAAMANS" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAAMANS" b2="69 KV" b3="64" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NAAMANS" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103473</SeqNum>
    <Name>DTX69.Naamans.T2</Name>
    <LastEdit Timestamp="2025-04-10T15:35:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NAAMANS" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAAMANS" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NAAMANS" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103474</SeqNum>
    <Name>DTX69.NewCastle.T1</Name>
    <LastEdit Timestamp="2025-04-10T15:36:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWCASTL" b2="69 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103475</SeqNum>
    <Name>DTX69.NewCastle.T2</Name>
    <LastEdit Timestamp="2025-04-10T15:37:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="69 KV" b3="66" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWCASTL" b2="69 KV" b3="LOADT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103476</SeqNum>
    <Name>DTX69.NewCastle.T3</Name>
    <LastEdit Timestamp="2025-04-10T15:39:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="69 KV" b3="66" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWCASTL" b2="69 KV" b3="68" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEWCASTL" b2="69 KV" b3="LOADT3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103477</SeqNum>
    <Name>DTX69.OceanCity.T1</Name>
    <LastEdit Timestamp="2025-04-10T15:40:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANCTY" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANCTY" b2="69 KV" b3="7270" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OCEANCTY" b2="69 KV" b3="LOADT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103478</SeqNum>
    <Name>DTX69.OceanCity.T2</Name>
    <LastEdit Timestamp="2025-04-10T15:40:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANCTY" b2="69 KV" b3="40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OCEANCTY" b2="69 KV" b3="7270" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OCEANCTY" b2="69 KV" b3="LOADT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103479</SeqNum>
    <Name>DTX69.Stevensville.T2</Name>
    <LastEdit Timestamp="2025-04-10T15:41:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STVNSVIL" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STVNSVIL" b2="69 KV" b3="62" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STVNSVIL" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103480</SeqNum>
    <Name>230/69.Gloucester.220-5TR</Name>
    <LastEdit Timestamp="2025-04-10T16:05:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="69 KV" b3="1-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="230 KV" b3="220-5CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GLOUCEST" b2="230 KV" b3="220-5TR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLOUCEST" b2="69 KV" b3="5-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103481</SeqNum>
    <Name>L138.Logan-Chauncey-Sprigg-Stone</Name>
    <LastEdit Timestamp="2025-09-12T10:59:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CHAUNCEY" b2="138 KV" b3="CHA-CHA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHAUNCEY" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAUNCYT" b2="138 KV" b3="CHA-LOG1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHAUNCYT" b2="138 KV" b3="CHA-SPR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGAN" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SPRIGG" b2="138 KV" b3="MOBAP104" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SPRIGG" b2="138 KV" b3="SS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STONE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="STONE" b2="138 KV" b3="STO-SPR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103482</SeqNum>
    <Name>L138.Inez-Hat-Borde-Cinderella-Sprig-PineCr-Logan</Name>
    <LastEdit Timestamp="2025-09-12T09:34:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BORDERLA" b2="138 KV" b3="BOR-CIN1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BORDERLA" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CINDEREL" b2="138 KV" b3="CIN-SPR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CINDEREL" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GRANTBRA" b2="138 KV" b3="GRA-PIG1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GRANTBRA" b2="138 KV" b3="T1T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HATFIEL2" b2="138 KV" b3="HAT-BOR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HATFIEL2" b2="138 KV" b3="HAT-INE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HATFIEL2" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INEZ" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INEZ" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOGAN" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOGAN" b2="138 KV" b3="LOG-PIN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PIGEONCR" b2="138 KV" b3="PIG-RAG1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PIGEONCR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PIGEONCR" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINECREE" b2="138 KV" b3="PIN-PIN5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PINECREE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PINECRTP" b2="138 KV" b3="PIN-RAG1" />
      <ContingencyEquipment Action="L" Type="LN" b1="RAGLAND" b2="138 KV" b3="RAG-SPR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RAGLAND" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SPRIGG" b2="138 KV" b3="SS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103483</SeqNum>
    <Name>L500.Marshall-Cumberland (TVA)</Name>
    <LastEdit Timestamp="2025-04-15T13:48:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CUMBERL" b2="500 KV" b3="32217A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMBERL" b2="500 KV" b3="5024" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CUMBERL" b2="500 KV" b3="5029" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHAL" b2="500 KV" b3="5044" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARSHAL" b2="500 KV" b3="5074" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103484</SeqNum>
    <Name>L345.Shawnee4-E W FKF3 (TVA)</Name>
    <LastEdit Timestamp="2025-04-15T14:01:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="SHAWNEE4" b2="345 KV" b3="32177A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E W FKF3" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E W FKF3" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEE4" b2="345 KV" b3="3028" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHAWNEE4" b2="345 KV" b3="3038" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103488</SeqNum>
    <Name>DTX138.Cyprus.Feathf</Name>
    <LastEdit Timestamp="2025-04-15T13:56:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CYPRUS" b2="138 KV" b3="FEATHF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H018A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H018A5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103494</SeqNum>
    <Name>L115.Northwood-Glendon</Name>
    <LastEdit Timestamp="2025-04-25T09:22:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLENDON" b2="115 KV" b3="95132" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="GLENDON" b2="115 KV" b3="DUMF1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLENDON" b2="115 KV" b3="GLE-NORW" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="115 KV" b3="B169" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORTHWOO" b2="115 KV" b3="B171" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103498</SeqNum>
    <Name>DTX138.Marion.T7</Name>
    <LastEdit Timestamp="2025-05-01T09:45:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="H015A5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="H015A8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARION2" b2="138 KV" b3="T7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103499</SeqNum>
    <Name>138/34.Hardy.T1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-03-12T13:43:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="HARDY" b2="138 KV" b3="CAP3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDY" b2="138 KV" b3="CS31" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="HARDY" b2="138 KV" b3="T1 DIS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARDY" b2="34.5 KV" b3="T1LCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="HARDY" b2="138 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103500</SeqNum>
    <Name>ColonialTrail.SprgrvSP</Name>
    <LastEdit Timestamp="2026-05-11T11:45:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLTRAIL" b2="230 KV" b3="GENCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLTRAIL" b2="230 KV" b3="GSU2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COLTRAIL" b2="34.5 KV" b3="SPRNG2SP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103502</SeqNum>
    <Name>DTX138.79Spaulding.TR71</Name>
    <LastEdit Timestamp="2025-05-02T15:29:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="138 KV" b3="L7901_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="79 SPAUL" b2="138 KV" b3="L7910 CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="79 SPAUL" b2="138 KV" b3="LOADTR71" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="79 SPAUL" b2="138 KV" b3="TR76 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103505</SeqNum>
    <Name>DTX138.78FranklinPark.TR76</Name>
    <LastEdit Timestamp="2025-05-19T09:04:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="138 KV" b3="BT1-2 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="78 FRANK" b2="138 KV" b3="BT1-8CB" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="78 FRANK" b2="34.5 KV" b3="TR76" />
      <ContingencyEquipment Action="X" Type="XF" b1="78 FRANK" b2="138 KV" b3="TR76 34" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="78 FRANK" b2="138 KV" b3="TR76 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103506</SeqNum>
    <Name>345/34.MeadowLake4.T1-GSU + MeadowLake.WF4&amp;5</Name>
    <LastEdit Timestamp="2025-05-05T13:17:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWL4" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEADOWL4" b2="345 KV" b3="BT1-2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="MEADOWL4" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEADOWL4" b2="34.5 KV" b3="MEDLK4WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MEADOWL4" b2="34.5 KV" b3="MEDLK5WF" />
      <ContingencyEquipment Action="X" Type="XF" b1="MEADOWL4" b2="345 KV" b3="T-1GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103512</SeqNum>
    <Name>SouthReading.Titus4</Name>
    <LastEdit Timestamp="2025-05-08T13:51:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SREADING" b2="69 KV" b3="10 BNK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SREADING" b2="69 KV" b3="B10-85" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SREADING" b2="13 KV" b3="G4-10B2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SREADING" b2="13 KV" b3="TITUS4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103513</SeqNum>
    <Name>SouthReading.Titus5</Name>
    <LastEdit Timestamp="2025-05-08T13:53:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SREADING" b2="69 KV" b3="12 BNK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SREADING" b2="69 KV" b3="B12-85" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SREADING" b2="13 KV" b3="G5-12B2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SREADING" b2="13 KV" b3="TITUS5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103514</SeqNum>
    <Name>L345.Bermuda-Corridor</Name>
    <LastEdit Timestamp="2026-04-14T15:15:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BERMUDA" b2="345 KV" b3="BER-CORR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERMUDA" b2="345 KV" b3="H021G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERMUDA" b2="345 KV" b3="H021G5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="345 KV" b3="303C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CORRIDOR" b2="345 KV" b3="303S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103515</SeqNum>
    <Name>345/138.Innovation.T1</Name>
    <LastEdit Timestamp="2025-05-08T14:18:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H002E5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H002E8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="345 KV" b3="H010Q5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="345 KV" b3="H010R5" />
      <ContingencyEquipment Action="X" Type="XF" b1="INNOVATI" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103520</SeqNum>
    <Name>L69.Church-Blanco.6792</Name>
    <LastEdit Timestamp="2025-05-13T10:58:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLANCO" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLANCO" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="7220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHURCH" b2="69 KV" b3="7290" />
      <ContingencyEquipment Action="L" Type="LN" b1="BLANCO" b2="69 KV" b3="BLA-CHUR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103521</SeqNum>
    <Name>Blanco.JonesSP</Name>
    <LastEdit Timestamp="2025-05-13T10:59:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BLANCO" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BLANCO" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BLANCO" b2="34.5 KV" b3="JONESSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="BLANCO" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103522</SeqNum>
    <Name>345/138.Innovation.T2</Name>
    <LastEdit Timestamp="2025-05-15T12:54:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H002G5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H002G8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="345 KV" b3="H010Q2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="345 KV" b3="H010R2" />
      <ContingencyEquipment Action="X" Type="XF" b1="INNOVATI" b2="345 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103527</SeqNum>
    <Name>L138.Horizon-Badger</Name>
    <LastEdit Timestamp="2025-05-20T09:19:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BADGRAEP" b2="138 KV" b3="BAD-HORI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BADGRAEP" b2="138 KV" b3="H007L5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BADGRAEP" b2="138 KV" b3="H007L8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON" b2="138 KV" b3="H012C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON" b2="138 KV" b3="H012C5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103528</SeqNum>
    <Name>L138.Horizon-GreenChapel</Name>
    <LastEdit Timestamp="2025-05-20T09:23:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GREENCHA" b2="138 KV" b3="GRE-HORI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008K5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON" b2="138 KV" b3="H012D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON" b2="138 KV" b3="H012D5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103529</SeqNum>
    <Name>L230.LostCity-WhiteOak.2282B</Name>
    <LastEdit Timestamp="2025-05-22T13:50:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOSTCIT2" b2="230 KV" b3="22822313" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOSTCIT2" b2="230 KV" b3="228262" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEOA4" b2="230 KV" b3="228242-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEOA4" b2="230 KV" b3="228242-6" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOSTCIT2" b2="230 KV" b3="LOS-WHIT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103532</SeqNum>
    <Name>L138.Carson-Watson.Z-89</Name>
    <LastEdit Timestamp="2025-05-21T11:16:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CARS DUQ" b2="138 KV" b3="CAR-WATS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CARS DUQ" b2="138 KV" b3="Z-89" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATSON2" b2="138 KV" b3="TIE3-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WATSON2" b2="138 KV" b3="TIE6-7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103533</SeqNum>
    <Name>DTX138.Marion.T10</Name>
    <LastEdit Timestamp="2025-06-12T11:47:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="H015A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="H024T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARION2" b2="138 KV" b3="T10" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103534</SeqNum>
    <Name>DTX138.Jerome.C4</Name>
    <LastEdit Timestamp="2025-05-27T13:57:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JEROMEOH" b2="138 KV" b3="C4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEROMEOH" b2="138 KV" b3="H010G5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEROMEOH" b2="138 KV" b3="H010G8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103535</SeqNum>
    <Name>L69.Gibson-AMPPark-Oberlin-Swatara-Hummelstown.2</Name>
    <LastEdit Timestamp="2025-05-28T13:49:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMPPARK1" b2="69 KV" b3="AP1-OBE2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMPPARK1" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="AMPPARK1" b2="69 KV" b3="TRAN1-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMPPARK2" b2="69 KV" b3="AP2-SWA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMPPARK2" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="AMPPARK2" b2="69 KV" b3="TRAN1-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMPPARK1" b2="69 KV" b3="AMP-GIBS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON" b2="69 KV" b3="HUM1WSH2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON" b2="69 KV" b3="HUMM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="69 KV" b3="HARR1-E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="69 KV" b3="HARR1-W" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMPPARK2" b2="69 KV" b3="AP2-OBE2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OBRLINPL" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUMMELST" b2="69 KV" b3="HUM1-SWA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SWATARA" b2="69 KV" b3="TRAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103536</SeqNum>
    <Name>L345.Beason-MtPulaski.18806</Name>
    <LastEdit Timestamp="2025-05-28T10:30:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="188 MTPU" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="188 MTPU" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="987_BEAS" b2="345 KV" b3="BEA-MTPU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="987_BEAS" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="987_BEAS" b2="345 KV" b3="3-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103537</SeqNum>
    <Name>L345.Beason-TopHatWindFarm.98701 + 926TopH.WF</Name>
    <LastEdit Timestamp="2025-05-28T10:35:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="926_TOPH" b2="34.5 KV" b3="TOPHATWF" />
      <ContingencyEquipment Action="X" Type="XF" b1="926_TOPH" b2="345 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="926_TOPH" b2="345 KV" b3="TR1_CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="926_TOPH" b2="345 KV" b3="TR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="926_TOPH" b2="345 KV" b3="TR2_CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="987_BEAS" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="987_BEAS" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="987_BEAS" b2="345 KV" b3="BEA-TOPH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103538</SeqNum>
    <Name>DTX138.Jerome.C1</Name>
    <LastEdit Timestamp="2025-05-28T10:58:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JEROMEOH" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEROMEOH" b2="138 KV" b3="H009Z8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEROMEOH" b2="138 KV" b3="H011N8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103539</SeqNum>
    <Name>DTX138.Jerome.C3</Name>
    <LastEdit Timestamp="2025-05-28T11:00:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="JEROMEOH" b2="138 KV" b3="C3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEROMEOH" b2="138 KV" b3="H010F2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEROMEOH" b2="138 KV" b3="H010F5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103540</SeqNum>
    <Name>L138.CampWashington-SFairmount.27987</Name>
    <LastEdit Timestamp="2025-05-29T13:25:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMP_WSH" b2="138 KV" b3="811" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMP_WSH" b2="138 KV" b3="819" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAMP_WSH" b2="138 KV" b3="TB3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOUTHFMT" b2="138 KV" b3="976" />
      <ContingencyEquipment Action="L" Type="LN" b1="CAMP_WSH" b2="138 KV" b3="CAM-SOUT" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103541</SeqNum>
    <Name>DTX138.CampWashington.TB2</Name>
    <LastEdit Timestamp="2025-05-29T13:26:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMP_WSH" b2="138 KV" b3="815" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CAMP_WSH" b2="138 KV" b3="819" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CAMP_WSH" b2="138 KV" b3="TB2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103542</SeqNum>
    <Name>DTX138.E535.TR71</Name>
    <LastEdit Timestamp="2025-05-30T10:00:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="E535" b2="138 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E535" b2="138 KV" b3="1-4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="E535" b2="138 KV" b3="TR71" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103543</SeqNum>
    <Name>DTX138.E535.TR74</Name>
    <LastEdit Timestamp="2025-05-30T10:01:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="E535" b2="138 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E535" b2="138 KV" b3="3-4" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="E535" b2="138 KV" b3="TR74" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103544</SeqNum>
    <Name>L115.GoaldersCreek-OwlTrap.1060</Name>
    <LastEdit Timestamp="2025-08-22T10:35:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GLDRSCRK" b2="115 KV" b3="10601071" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLDRSCRK" b2="115 KV" b3="85T1060" />
      <ContingencyEquipment Action="L" Type="LN" b1="GLDRSCRK" b2="115 KV" b3="GLD-OWLT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OWLTRAP" b2="115 KV" b3="10331060" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OWLTRAP" b2="115 KV" b3="106022" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103545</SeqNum>
    <Name>GoaldersCreek.WalnutSP</Name>
    <LastEdit Timestamp="2025-05-30T11:15:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="GLDRSCRK" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GLDRSCRK" b2="115 KV" b3="WALNUTCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GLDRSCRK" b2="34.5 KV" b3="WALNUTSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103546</SeqNum>
    <Name>230/115.Yorkana.T1</Name>
    <LastEdit Timestamp="2025-06-05T12:39:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="115 KV" b3="1B82" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="230 KV" b3="B121" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YORKANA" b2="230 KV" b3="B14" />
      <ContingencyEquipment Action="X" Type="XF" b1="YORKANA" b2="230 KV" b3="BANK 1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103547</SeqNum>
    <Name>DTX138.GreenChapel.T7</Name>
    <LastEdit Timestamp="2025-05-30T11:25:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008N5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008N8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENCHA" b2="138 KV" b3="T7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103553</SeqNum>
    <Name>230/69.Lumberton.T220-6</Name>
    <LastEdit Timestamp="2025-06-06T17:09:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMBERTO" b2="69 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMBERTO" b2="230 KV" b3="220-6CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LUMBERTO" b2="69 KV" b3="3-4" />
      <ContingencyEquipment Action="X" Type="XF" b1="LUMBERTO" b2="230 KV" b3="T-220-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103554</SeqNum>
    <Name>L69.Benton-Bowman-Scott-Univ-Columbia</Name>
    <LastEdit Timestamp="2025-06-12T11:17:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENTON" b2="69 KV" b3="BEFO_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENTON" b2="69 KV" b3="BEN-BOWM" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENTON" b2="69 KV" b3="BEN-ROHR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENTON" b2="69 KV" b3="BENT1_LD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="BENTON" b2="69 KV" b3="BENT_CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="69 KV" b3="GLBR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOWMANSM" b2="69 KV" b3="BOW-SCO2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SCOTTPL" b2="69 KV" b3="CAP2" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCOTTPL" b2="69 KV" b3="SCO-UNI2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCOTTPL" b2="69 KV" b3="SCOT2 LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLU PL" b2="69 KV" b3="COL-UNI2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIVERPL" b2="69 KV" b3="UNIV_LD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103555</SeqNum>
    <Name>L69.Juniata-Benvenue-Greenpark-Shermdale.1</Name>
    <LastEdit Timestamp="2025-12-11T09:57:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENVENUE" b2="69 KV" b3="BENV1_LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENVENUE" b2="69 KV" b3="NEBL_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENVENUE" b2="69 KV" b3="BEN-GRE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENPAR" b2="69 KV" b3="GRE-SHE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENVENUE" b2="69 KV" b3="BEN-JUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="69 KV" b3="SDLE1_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="69 KV" b3="SDLE1_S" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHERMAND" b2="69 KV" b3="5317" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHERMAND" b2="69 KV" b3="SSHE_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103556</SeqNum>
    <Name>L69.Juniata-Benvenue-Greenpark-Shermdale.2</Name>
    <LastEdit Timestamp="2025-06-11T16:56:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BENVENUE" b2="69 KV" b3="BENV2_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENVENUE" b2="69 KV" b3="BEN-GRE2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENPAR" b2="69 KV" b3="GRE-SHE2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENPAR" b2="69 KV" b3="GRPA_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="BENVENUE" b2="69 KV" b3="BEN-JUN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="69 KV" b3="SDLE2_N" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHERMAND" b2="69 KV" b3="SDLE_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103557</SeqNum>
    <Name>L69.Lycoming-KenmarTap-Clinton.1</Name>
    <LastEdit Timestamp="2025-06-11T16:39:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON" b2="69 KV" b3="LYC1MUN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON" b2="69 KV" b3="LYCO1" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINTON" b2="69 KV" b3="CLI-KEN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENMARTP" b2="69 KV" b3="KEN-LYC1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KENMARTP" b2="69 KV" b3="KEN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="CLIN1_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="CLIN1_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103558</SeqNum>
    <Name>L69.Lycoming-KenmarTap-Clinton.2</Name>
    <LastEdit Timestamp="2025-06-11T16:39:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON" b2="69 KV" b3="LYC2MIL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINTON" b2="69 KV" b3="LYCO2W" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINTON" b2="69 KV" b3="CLI-KEN2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KENMARTP" b2="69 KV" b3="KEN-LYC2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KENMARTP" b2="69 KV" b3="KEN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="CLIN2_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LYCOMING" b2="69 KV" b3="CLIN2_S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103559</SeqNum>
    <Name>L69.Copperst-Ruthford-Lawnton-Harrisburg.1</Name>
    <LastEdit Timestamp="2025-12-11T15:46:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="69 KV" b3="D2-H1TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="69 KV" b3="HARR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISBU" b2="69 KV" b3="COPP1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRISBU" b2="69 KV" b3="HAR-LAW1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAWNTON" b2="69 KV" b3="5167" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAWNTON" b2="69 KV" b3="T3" />
      <ContingencyEquipment Action="L" Type="LN" b1="COPPERST" b2="69 KV" b3="COP-RUT" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAWNTON" b2="69 KV" b3="LAW-RUT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RUTHFORD" b2="69 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103560</SeqNum>
    <Name>L69.Copperst-Rutherford-Lawnton-Harrisburg.2</Name>
    <LastEdit Timestamp="2025-12-11T15:44:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="69 KV" b3="H2-D1TIE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPPERST" b2="69 KV" b3="HARR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISBU" b2="69 KV" b3="COPP2" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRISBU" b2="69 KV" b3="HAR-LAW2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="LAWNTON" b2="69 KV" b3="5167" />
      <ContingencyEquipment Action="L" Type="LN" b1="LAWNTON" b2="69 KV" b3="LAW-RUT2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LAWNTON" b2="69 KV" b3="T4" />
      <ContingencyEquipment Action="L" Type="LN" b1="COPPERST" b2="69 KV" b3="COP-RUT2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RUTHFORD" b2="69 KV" b3="LD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103561</SeqNum>
    <Name>L69.Millv-Rohr-Bowman-Scott-Univ-Columb</Name>
    <LastEdit Timestamp="2025-06-11T16:40:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="BOWMANSM" b2="69 KV" b3="BOMI_CAP" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOWMANSM" b2="69 KV" b3="BOW-ROHR" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOWMANSM" b2="69 KV" b3="BOW-SCO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BOWMANSM" b2="69 KV" b3="W610_LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLU PL" b2="69 KV" b3="GLBR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MILLVIL2" b2="69 KV" b3="MVIL2_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROHRSBUR" b2="69 KV" b3="ROH-ROHR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROHRSBUR" b2="69 KV" b3="ROHR1_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILLVIL2" b2="69 KV" b3="MIL-ROHR" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="SCOTTPL" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCOTTPL" b2="69 KV" b3="SCOT1 LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="COLU PL" b2="69 KV" b3="COL-UNI1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SCOTTPL" b2="69 KV" b3="SCO-UNI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="UNIVERPL" b2="69 KV" b3="UNIV_LD1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103564</SeqNum>
    <Name>L115.ScotlandNeck-BynumsBridge.1070</Name>
    <LastEdit Timestamp="2025-06-11T15:40:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BYNMSBRD" b2="115 KV" b3="10151070" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BYNMSBRD" b2="115 KV" b3="10701084" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOTLAND" b2="115 KV" b3="126T1070" />
      <ContingencyEquipment Action="L" Type="LN" b1="BYNMSBRD" b2="115 KV" b3="BYN-SCOT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCOTLAND" b2="115 KV" b3="H272" />
      <ContingencyEquipment Action="X" Type="XF" b1="SCOTLAND" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCOTLAND" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCOTLAND" b2="13 KV" b3="TX2H_NCE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SCOTLAND" b2="13 KV" b3="TX2_NCE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103566</SeqNum>
    <Name>230/69.Palooka.1</Name>
    <LastEdit Timestamp="2025-06-11T16:32:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PALOOKA" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALOOKA" b2="230 KV" b3="TRAN1HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALOOKA" b2="69 KV" b3="TRAN1LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103567</SeqNum>
    <Name>230/69.Palooka.2</Name>
    <LastEdit Timestamp="2025-06-11T16:32:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="PALOOKA" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALOOKA" b2="230 KV" b3="TRAN2HCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALOOKA" b2="69 KV" b3="TRAN2LCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103568</SeqNum>
    <Name>230/69.SummitPl.T1</Name>
    <LastEdit Timestamp="2025-06-11T16:35:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SUMMITPL" b2="230 KV" b3="T1_XFMR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMITPL" b2="230 KV" b3="TRAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMITPL" b2="69 KV" b3="TRAN1_69" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103569</SeqNum>
    <Name>230/69.SummitPl.T2</Name>
    <LastEdit Timestamp="2025-06-11T16:36:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="SUMMITPL" b2="230 KV" b3="T2_XFMR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMITPL" b2="230 KV" b3="TRAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMITPL" b2="69 KV" b3="TRAN2_69" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103570</SeqNum>
    <Name>L69.Cumberland-WCarlisleTap.1</Name>
    <LastEdit Timestamp="2025-11-17T12:05:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CUMB PL" b2="69 KV" b3="CUM-WCT1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CUMB PL" b2="69 KV" b3="WCAR1INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="69 KV" b3="WCAR_1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHERMAND" b2="69 KV" b3="5317" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WCARLTAP" b2="69 KV" b3="5027" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WCARLTAP" b2="69 KV" b3="5213" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WCARLTAP" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCARLTAP" b2="69 KV" b3="CAP1_CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHERMAND" b2="69 KV" b3="SHE-WCA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WCARLTAP" b2="69 KV" b3="WCAR1_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103571</SeqNum>
    <Name>L69.Cumberland-WCarlisleTap.2</Name>
    <LastEdit Timestamp="2025-11-17T12:06:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CUMB PL" b2="69 KV" b3="CUM-WCT2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CUMB PL" b2="69 KV" b3="WCAR2INS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="69 KV" b3="WCAR_2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHERMAND" b2="69 KV" b3="5318" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WCARLTAP" b2="69 KV" b3="5026" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WCARLTAP" b2="69 KV" b3="5213" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHERMAND" b2="69 KV" b3="SHE-WCAR" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WCARLTAP" b2="69 KV" b3="WCAR2 LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103572</SeqNum>
    <Name>L138.Howard-RedRun</Name>
    <LastEdit Timestamp="2025-06-12T12:50:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOWARD2" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOWARD2" b2="138 KV" b3="HOW-REDR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDRUNAE" b2="138 KV" b3="H005X8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDRUNAE" b2="138 KV" b3="H005Y2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103573</SeqNum>
    <Name>L230.Beaumeade-DTC.2143</Name>
    <LastEdit Timestamp="2025-06-12T13:01:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="21162143" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="21302143" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DTC" b2="230 KV" b3="214342" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAUMEAD" b2="230 KV" b3="BEA-DTC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DTC" b2="230 KV" b3="H12T2143" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103574</SeqNum>
    <Name>L345/138.Foxhills-Goethals (SENY)</Name>
    <LastEdit Timestamp="2025-06-13T07:40:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FOXHILLS" b2="138 KV" b3="8N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FOXHILLS" b2="138 KV" b3="9X" />
      <ContingencyEquipment Action="L" Type="LN" b1="FOXHILLS" b2="138 KV" b3="FOX-GOET" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOETHALS" b2="345 KV" b3="6X" />
      <ContingencyEquipment Action="P" Type="XF" b1="GOETHALS" b2="138 KV" b3="P6" />
      <ContingencyEquipment Action="X" Type="XF" b1="GOETHALS" b2="345 KV" b3="T6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103575</SeqNum>
    <Name>TEMP:L115.Plaza-BellW-BrwnBv-Kevl-Kngsl-Reym.53-72</Name>
    <LastEdit Timestamp="2026-03-09T14:45:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BELLWOOD" b2="115 KV" b3="7249" />
      <ContingencyEquipment Action="L" Type="LN" b1="BELLWOOD" b2="115 KV" b3="72E" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLWOOD" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELLWOOD" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BELLWOOD" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BELLWOOD" b2="13 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROWNBOV" b2="115 KV" b3="72C" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROWNBOV" b2="115 KV" b3="72D" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROWNBOV" b2="115 KV" b3="BRO-KEVL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BROWNBOV" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="115 KV" b3="5312" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEVLAR" b2="115 KV" b3="53A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTER4" b2="115 KV" b3="7212" />
      <ContingencyEquipment Action="L" Type="LN" b1="REYMET" b2="115 KV" b3="72A" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTER4" b2="115 KV" b3="CHE-REYM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEVLAR" b2="115 KV" b3="5372" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEVLAR" b2="115 KV" b3="KEV-NATC" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEVLAR" b2="115 KV" b3="KEV-REYM" />
      <ContingencyEquipment Action="L" Type="LN" b1="REYMET" b2="115 KV" b3="72B" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTER4" b2="115 KV" b3="CHE-KING" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSLND" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KINGSLND" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="L" Type="LN" b1="NATCYL" b2="115 KV" b3="72F" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NATCYL" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLAZA" b2="115 KV" b3="7222" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REYMET" b2="115 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103579</SeqNum>
    <Name>Temp:L115.Curryville-Saxton.1099 (Sctnlz)Ed1254648</Name>
    <LastEdit Timestamp="2025-06-30T08:50:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="CURRYVIL" b2="115 KV" b3="12RS MOA" />
      <ContingencyEquipment Action="L" Type="LN" b1="CURRYVIL" b2="115 KV" b3="CUR-SAX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAXTON" b2="115 KV" b3="B24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAXTON" b2="115 KV" b3="B50" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103582</SeqNum>
    <Name>DTX230.Portugee.DPX74</Name>
    <LastEdit Timestamp="2025-06-16T10:14:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUGEE" b2="230 KV" b3="209172-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUGEE" b2="230 KV" b3="219872-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PORTUGEE" b2="230 KV" b3="DPX74" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103583</SeqNum>
    <Name>DTX230.Portugee.DPW74</Name>
    <LastEdit Timestamp="2025-06-16T10:15:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUGEE" b2="230 KV" b3="209172-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PORTUGEE" b2="230 KV" b3="219872-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PORTUGEE" b2="230 KV" b3="DPW74" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103585</SeqNum>
    <Name>115/46.SummitWest.TR1</Name>
    <LastEdit Timestamp="2025-06-19T22:00:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="115 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="46 KV" b3="B110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="46 KV" b3="B140" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="46 KV" b3="B170" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="115 KV" b3="B30" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUMMIT_W" b2="115 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103586</SeqNum>
    <Name>115/46.SummitWest.TR2</Name>
    <LastEdit Timestamp="2025-06-19T22:00:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="46 KV" b3="B130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="46 KV" b3="B160" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="46 KV" b3="B180" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="115 KV" b3="B40" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUMMIT_W" b2="115 KV" b3="B50" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUMMIT_W" b2="115 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103587</SeqNum>
    <Name>138/69.StubeyRoad.TR3</Name>
    <LastEdit Timestamp="2025-06-18T17:08:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="69 KV" b3="M000X2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="69 KV" b3="M000X5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="138 KV" b3="M001A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="138 KV" b3="M001A5" />
      <ContingencyEquipment Action="X" Type="XF" b1="STUBYROA" b2="138 KV" b3="TR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103588</SeqNum>
    <Name>138/69.StubeyRoad.TR2</Name>
    <LastEdit Timestamp="2025-06-18T17:08:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="STUBYROA" b2="69 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="69 KV" b3="M000X8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="69 KV" b3="M000Y8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="138 KV" b3="M000Z5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="138 KV" b3="M000Z8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STUBYROA" b2="69 KV" b3="M004Q5" />
      <ContingencyEquipment Action="X" Type="XF" b1="STUBYROA" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103590</SeqNum>
    <Name>L230.MtVernon-Harvard.23140</Name>
    <LastEdit Timestamp="2026-04-23T08:50:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVARD" b2="230 KV" b3="3A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARVARD" b2="230 KV" b3="3B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTVERPEP" b2="230 KV" b3="3A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MTVERPEP" b2="230 KV" b3="3B" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARVARD" b2="230 KV" b3="HAR-MTV2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103591</SeqNum>
    <Name>L230.RockyMountain-Wilson (CPL)</Name>
    <LastEdit Timestamp="2025-06-20T14:42:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="3ROCKY" b2="230 KV" b3="3RO-WILS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3ROCKY" b2="230 KV" b3="WLSN6HAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3ROCKY" b2="230 KV" b3="WLSN_2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON4" b2="230 KV" b3="RMT2_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103592</SeqNum>
    <Name>L345.Douglas-Francisco[CIN]</Name>
    <LastEdit Timestamp="2026-01-28T08:01:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUGLAS2" b2="345 KV" b3="16-52" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUGLAS2" b2="345 KV" b3="52-53" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOUGLAS2" b2="345 KV" b3="DOU-FRCS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRCSCCIN" b2="345 KV" b3="3200" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRCSCCIN" b2="345 KV" b3="3600" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103593</SeqNum>
    <Name>L345.Montgomery-Root</Name>
    <LastEdit Timestamp="2025-06-22T20:54:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MONTGMR3" b2="345 KV" b3="MON-ROOT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTGMR3" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTGMR3" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROOT" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROOT" b2="345 KV" b3="V7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103595</SeqNum>
    <Name>L230.RockyMountain-Person (CPL)</Name>
    <LastEdit Timestamp="2025-11-19T14:19:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="3ROCKY" b2="230 KV" b3="3RO-CAST" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3ROCKY" b2="230 KV" b3="PERS6HAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3ROCKY" b2="230 KV" b3="PERS_2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CASTALIA" b2="230 KV" b3="BK1_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="CASTALIA" b2="230 KV" b3="CAS-PBCS" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HENDE" b2="230 KV" b3="87_TOPOL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HENDE" b2="230 KV" b3="BK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="HENDE" b2="230 KV" b3="HEN-PBCS" />
      <ContingencyEquipment Action="L" Type="LN" b1="HENDERSN" b2="230 KV" b3="31007A" />
      <ContingencyEquipment Action="L" Type="LN" b1="HENDERSN" b2="230 KV" b3="HEN-OXF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OXFORDN" b2="230 KV" b3="BK1" />
      <ContingencyEquipment Action="L" Type="LN" b1="OXFORDN" b2="230 KV" b3="OXF-OXF" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OXFST" b2="230 KV" b3="79_TOPO1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OXFST" b2="230 KV" b3="BK2" />
      <ContingencyEquipment Action="L" Type="LN" b1="OXFST" b2="230 KV" b3="RMT2_PER" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PBCS" b2="230 KV" b3="PV01" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERSON4" b2="230 KV" b3="HEND_RMT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PERSON4" b2="230 KV" b3="RMT2_2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103596</SeqNum>
    <Name>L115.RockyMountain-Wilson (CPL)</Name>
    <LastEdit Timestamp="2025-07-01T11:54:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="3ROCKY" b2="115 KV" b3="ROC-SHAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="3ROCKY" b2="115 KV" b3="WLSN_1E" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAVENPRT" b2="115 KV" b3="DAV-ELM" />
      <ContingencyEquipment Action="L" Type="LN" b1="DAVENPRT" b2="115 KV" b3="DAV-SHA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAVENPRT" b2="115 KV" b3="DAVEN" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DAVENPRT" b2="115 KV" b3="WILSON" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="ELMCITY" b2="115 KV" b3="227_TOP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ELMCITY" b2="115 KV" b3="227_TOPO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHARPSBG" b2="115 KV" b3="SHARP" />
      <ContingencyEquipment Action="L" Type="LN" b1="WILSON4" b2="115 KV" b3="RKMT_WL2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSON4" b2="115 KV" b3="RMT2_1E" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103601</SeqNum>
    <Name>L69.Hanover-Parrish-WilkesBarre-Palooka</Name>
    <LastEdit Timestamp="2025-09-23T13:29:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="BLYTHEBU" b2="69 KV" b3="2253" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANOVER" b2="69 KV" b3="66410" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANOVER" b2="69 KV" b3="HAN-PAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALOOKA" b2="69 KV" b3="HARW1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PALOOKA" b2="69 KV" b3="JEN-HAR1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PARRISPL" b2="69 KV" b3="PAR-WIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PARRISPL" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WILKBARR" b2="69 KV" b3="DUM3" />
      <ContingencyEquipment Action="L" Type="LN" b1="PALOOKA" b2="69 KV" b3="PAL-WIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILKBARR" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILKBARR" b2="69 KV" b3="TRAN1" />
      <ContingencyEquipment Action="L" Type="LN" b1="WILKBARR" b2="69 KV" b3="WIL-WRI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WRIGHT_T" b2="69 KV" b3="WRTP1_LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103603</SeqNum>
    <Name>RedRun.SycamcSP</Name>
    <LastEdit Timestamp="2025-07-28T17:47:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="REDRUNAE" b2="138 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDRUNAE" b2="138 KV" b3="H005X5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDRUNAE" b2="138 KV" b3="H005Y2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="REDRUNAE" b2="34.5 KV" b3="SYCAMCSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103604</SeqNum>
    <Name>L138.Robison-Reed-Trier</Name>
    <LastEdit Timestamp="2025-12-09T16:14:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REED" b2="138 KV" b3="M005H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REED" b2="138 KV" b3="M005H5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REED" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REED" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="L" Type="LN" b1="REED" b2="138 KV" b3="REE-ROB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRIER" b2="138 KV" b3="M000S2" />
      <ContingencyEquipment Action="L" Type="LN" b1="REED" b2="138 KV" b3="REE-TRI1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="TRIER" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRIER" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103605</SeqNum>
    <Name>L138.Lincoln-AnthonyTap-StateStreet-Trier</Name>
    <LastEdit Timestamp="2025-08-11T10:34:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ANTHONY" b2="138 KV" b3="T5" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANTHONY" b2="138 KV" b3="ANT-ANT2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANTHONYT" b2="138 KV" b3="ANT-LIN2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANTHONYT" b2="138 KV" b3="ANT-STA1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN2" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STATESTR" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STATESTR" b2="138 KV" b3="XT1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRIER" b2="138 KV" b3="M000S2" />
      <ContingencyEquipment Action="L" Type="LN" b1="STATESTR" b2="138 KV" b3="STA-TRI1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103607</SeqNum>
    <Name>L230.Hourglass-Sandlot.2230</Name>
    <LastEdit Timestamp="2025-08-07T16:05:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HOURGLAS" b2="230 KV" b3="223062-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HOURGLAS" b2="230 KV" b3="223062-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDLOT" b2="230 KV" b3="22252230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDLOT" b2="230 KV" b3="223042" />
      <ContingencyEquipment Action="L" Type="LN" b1="HOURGLAS" b2="230 KV" b3="HOU-SAND" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103608</SeqNum>
    <Name>L161.EBowlingGreen-Aberdeen-Paradise(TVA)</Name>
    <LastEdit Timestamp="2025-07-04T07:22:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="E_BOWL" b2="161 KV" b3="ABE-EBO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="E_BOWL" b2="161 KV" b3="914" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARADIS" b2="161 KV" b3="858" />
      <ContingencyEquipment Action="L" Type="LN" b1="ABERD_T" b2="161 KV" b3="ABE-PAR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103609</SeqNum>
    <Name>L345.Albion-Gibson(MISO)</Name>
    <LastEdit Timestamp="2025-07-04T07:42:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALBION 3" b2="345 KV" b3="ALB-GIB1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBION 3" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALBION 3" b2="345 KV" b3="V7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON2" b2="345 KV" b3="09G3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON2" b2="345 KV" b3="4509" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103611</SeqNum>
    <Name>MoonCorner.BookerSP</Name>
    <LastEdit Timestamp="2025-10-22T10:57:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOONCRNR" b2="115 KV" b3="52TP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOONCRNR" b2="34.5 KV" b3="BOOKERCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOONCRNR" b2="34.5 KV" b3="BOOKERSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOONCRNR" b2="115 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103612</SeqNum>
    <Name>MoonCorner.CerulnSP</Name>
    <LastEdit Timestamp="2025-10-22T12:51:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOONCRNR" b2="115 KV" b3="CERULNCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MOONCRNR" b2="34.5 KV" b3="CERULNSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="MOONCRNR" b2="115 KV" b3="GSU2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103613</SeqNum>
    <Name>L345.CaseyWest-Zeke (Ameren)</Name>
    <LastEdit Timestamp="2025-07-07T15:04:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CASEY  3" b2="345 KV" b3="3528" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CASEY  3" b2="345 KV" b3="3529" />
      <ContingencyEquipment Action="L" Type="LN" b1="CASEY  3" b2="345 KV" b3="CAS-ZEKE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZEKE" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZEKE" b2="345 KV" b3="V5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103614</SeqNum>
    <Name>L138.Brie-Innovation.1</Name>
    <LastEdit Timestamp="2025-07-10T19:09:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRIE" b2="138 KV" b3="BRI-INN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H020K2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H020K5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H002F5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H002F8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103615</SeqNum>
    <Name>L138.Brie-Innovation.2</Name>
    <LastEdit Timestamp="2026-01-20T10:19:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BRIE" b2="138 KV" b3="BRI-INN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H020J2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRIE" b2="138 KV" b3="H020J5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H002E2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="138 KV" b3="H002E5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="INNOVATI" b2="138 KV" b3="SKIDAP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103616</SeqNum>
    <Name>BynumsBridge.AbeechSP</Name>
    <LastEdit Timestamp="2025-07-09T10:27:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BYNMSBRD" b2="115 KV" b3="ABEECHCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BYNMSBRD" b2="34.5 KV" b3="ABEECHSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="BYNMSBRD" b2="115 KV" b3="GSU" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103621</SeqNum>
    <Name>L500.Mosby-WishingStar.590B</Name>
    <LastEdit Timestamp="2026-02-06T12:17:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSBY" b2="500 KV" b3="59072" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSBY" b2="500 KV" b3="XT590" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WISHSTAR" b2="500 KV" b3="59042-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WISHSTAR" b2="500 KV" b3="59042-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOSBY" b2="500 KV" b3="MOS-WIS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103623</SeqNum>
    <Name>L500.Brambleton-WishingStar.501A</Name>
    <LastEdit Timestamp="2026-02-06T12:18:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="500 KV" b3="H1T501" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRAMBLET" b2="500 KV" b3="WT501" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WISHSTAR" b2="500 KV" b3="50142-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WISHSTAR" b2="500 KV" b3="50142-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRAMBLET" b2="500 KV" b3="BRA-WIS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103625</SeqNum>
    <Name>L500.WishingStar-Mars.527A</Name>
    <LastEdit Timestamp="2025-12-20T20:18:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARS2" b2="500 KV" b3="52792-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARS2" b2="500 KV" b3="52792-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WISHSTAR" b2="500 KV" b3="52742-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WISHSTAR" b2="500 KV" b3="52742-4" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARS2" b2="500 KV" b3="MAR-WIS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103626</SeqNum>
    <Name>230/138.Noblesville.T7 [CIN]</Name>
    <LastEdit Timestamp="2025-08-22T08:27:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NOBLESVI" b2="138 KV" b3="138230-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NOBLESVI" b2="230 KV" b3="230138-7" />
      <ContingencyEquipment Action="X" Type="XF" b1="NOBLESVI" b2="230 KV" b3="7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103627</SeqNum>
    <Name>L345.Gwynneville-Prescott [CIN]</Name>
    <LastEdit Timestamp="2025-07-15T13:33:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GWYNNEVI" b2="345 KV" b3="15-54" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GWYNNEVI" b2="345 KV" b3="B115" />
      <ContingencyEquipment Action="L" Type="LN" b1="PRESCTP" b2="345 KV" b3="PRE-GWY1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRESCTP" b2="345 KV" b3="15-B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRESCTP" b2="345 KV" b3="B1-15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103630</SeqNum>
    <Name>500/230.Mars.TX1</Name>
    <LastEdit Timestamp="2025-12-20T20:49:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARS2" b2="500 KV" b3="H192-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARS2" b2="500 KV" b3="H192-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARS2" b2="230 KV" b3="L192" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARS2" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103631</SeqNum>
    <Name>500/230.Mars.TX2</Name>
    <LastEdit Timestamp="2026-03-31T10:28:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARS2" b2="500 KV" b3="H292-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARS2" b2="500 KV" b3="H292-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARS2" b2="230 KV" b3="L292" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARS2" b2="230 KV" b3="L2T2291" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARS2" b2="500 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103632</SeqNum>
    <Name>L230.CabinRun-Mars.2287A</Name>
    <LastEdit Timestamp="2026-03-31T10:21:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINRUN" b2="230 KV" b3="22132287" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CABINRUN" b2="230 KV" b3="228712" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARS2" b2="230 KV" b3="22872095" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARS2" b2="230 KV" b3="228792" />
      <ContingencyEquipment Action="L" Type="LN" b1="CABINRUN" b2="230 KV" b3="CAB-MARS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103634</SeqNum>
    <Name>L230.Mars-Shelhorn.2095H</Name>
    <LastEdit Timestamp="2026-03-31T10:20:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARS2" b2="230 KV" b3="209592" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARS2" b2="230 KV" b3="22872095" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARS2" b2="230 KV" b3="MAR-SHEL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELHORN" b2="230 KV" b3="20952186" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELHORN" b2="230 KV" b3="209542" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103641</SeqNum>
    <Name>DTX230.Yeagertown.TR7</Name>
    <LastEdit Timestamp="2025-07-22T13:32:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="YEAGERTO" b2="230 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YEAGERTO" b2="230 KV" b3="B34" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="YEAGERTO" b2="230 KV" b3="NO7TR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103642</SeqNum>
    <Name>DTX230.Yeagertown.TR2</Name>
    <LastEdit Timestamp="2025-07-22T13:34:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="YEAGERTO" b2="230 KV" b3="B23" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YEAGERTO" b2="230 KV" b3="B26" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="YEAGERTO" b2="230 KV" b3="NO.2 T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103643</SeqNum>
    <Name>L230.Liberty-Wellington-Rixlew.2228</Name>
    <LastEdit Timestamp="2025-07-29T16:52:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="230 KV" b3="20802228" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIBERTY1" b2="230 KV" b3="222812" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIBERTY1" b2="230 KV" b3="LIB-WEL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIXLEW" b2="230 KV" b3="222852" />
      <ContingencyEquipment Action="L" Type="LN" b1="RIXLEW" b2="230 KV" b3="RIX-WELN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIXLEW" b2="230 KV" b3="VT2228" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WELNGTDP" b2="230 KV" b3="TX1LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103644</SeqNum>
    <Name>L230.Pioneer-Rixlew.2314</Name>
    <LastEdit Timestamp="2025-07-22T13:51:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PIONEER1" b2="230 KV" b3="21962314" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIONEER1" b2="230 KV" b3="231492" />
      <ContingencyEquipment Action="L" Type="LN" b1="PIONEER1" b2="230 KV" b3="PIO-RIXE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIXLEW" b2="230 KV" b3="231452" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIXLEW" b2="230 KV" b3="UT2314" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103645</SeqNum>
    <Name>DTX138.Rixlew.LD1</Name>
    <LastEdit Timestamp="2025-07-22T13:53:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIXLEW" b2="230 KV" b3="LD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIXLEW" b2="230 KV" b3="UT2314" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIXLEW" b2="230 KV" b3="VT2228" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103646</SeqNum>
    <Name>DTX138.Rixlew.LD2</Name>
    <LastEdit Timestamp="2025-07-22T13:54:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIXLEW" b2="230 KV" b3="222852" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIXLEW" b2="230 KV" b3="231452" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RIXLEW" b2="230 KV" b3="LD2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103648</SeqNum>
    <Name>TEMP:L138.Elima-WNewton-Lynn-Skenton-WildCree-Laru</Name>
    <LastEdit Timestamp="2025-08-07T11:45:52" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIMA" b2="138 KV" b3="E1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARUE" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARUE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="LARUE" b2="138 KV" b3="LAR-WILD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LYNNST" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LYNNST" b2="138 KV" b3="LYN-SKE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="SKENTON" b2="138 KV" b3="SKE-WIL1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="URWNEWTN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILDCREE" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIMA" b2="138 KV" b3="ELI-WNE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LYNNST" b2="138 KV" b3="LYN-WNE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="URWNEWTN" b2="138 KV" b3="URW-WNE1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103649</SeqNum>
    <Name>L345.Diaz-Moro2 (Amaren)</Name>
    <LastEdit Timestamp="2025-07-29T07:48:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DIAZ" b2="345 KV" b3="DIA-MORO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DIAZ" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DIAZ" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORO2" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MORO2" b2="345 KV" b3="V3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103650</SeqNum>
    <Name>230/34.Northeast.TX8</Name>
    <LastEdit Timestamp="2025-07-31T15:33:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="230 KV" b3="H862" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEAST" b2="230 KV" b3="TX8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEAST" b2="35 KV" b3="TX8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103651</SeqNum>
    <Name>230/34.Northeast.TX5</Name>
    <LastEdit Timestamp="2025-07-31T15:32:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEAST" b2="230 KV" b3="H562" />
      <ContingencyEquipment Action="X" Type="XF" b1="NEAST" b2="230 KV" b3="TX5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NEAST" b2="35 KV" b3="TX5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103652</SeqNum>
    <Name>L138.Elizabethtown-BrdtwLG-NelsonTap-NelsonC</Name>
    <LastEdit Timestamp="2025-08-01T15:08:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRDTW_LG" b2="138 KV" b3="B155_704" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELIZABET" b2="138 KV" b3="B034_714" />
      <ContingencyEquipment Action="L" Type="LN" b1="NELSON_C" b2="138 KV" b3="NEL-NELS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NELSON_C" b2="138 KV" b3="W76-808" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRDTW_LG" b2="138 KV" b3="NEL-BRDT" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELIZABET" b2="138 KV" b3="NEL-ELIZ" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103653</SeqNum>
    <Name>DTX138.Hannibal.Northsub</Name>
    <LastEdit Timestamp="2025-08-02T22:27:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNIBAL" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANNIBAL" b2="138 KV" b3="A1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HANNIBAL" b2="138 KV" b3="NORTHSUB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103657</SeqNum>
    <Name>L69.Copeland-Panhandle-Seaman</Name>
    <LastEdit Timestamp="2025-08-07T09:52:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COPELAND" b2="69 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COPELAND" b2="69 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="COPELAND" b2="69 KV" b3="COP-PANH" />
      <ContingencyEquipment Action="L" Type="LN" b1="PANHANDL" b2="69 KV" b3="PAN-SEA1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="PANHANDL" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SEAMAN" b2="69 KV" b3="64" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103669</SeqNum>
    <Name>138/69.KenzieCreek.T2</Name>
    <LastEdit Timestamp="2025-08-19T13:11:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="138 KV" b3="J2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="69 KV" b3="M003X2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KENZIECR" b2="69 KV" b3="M003Y2" />
      <ContingencyEquipment Action="X" Type="XF" b1="KENZIECR" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103671</SeqNum>
    <Name>Celestial.DullesSP</Name>
    <LastEdit Timestamp="2025-11-17T12:26:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CELESTIA" b2="230 KV" b3="213732" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELESTIA" b2="230 KV" b3="226132" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CELESTIA" b2="34.5 KV" b3="DULLE1SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CELESTIA" b2="34.5 KV" b3="DULLE2SP" />
      <ContingencyEquipment Action="X" Type="XF" b1="CELESTIA" b2="230 KV" b3="GSU" />
      <ContingencyEquipment Action="X" Type="XF" b1="CELESTIA" b2="230 KV" b3="GSU2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103675</SeqNum>
    <Name>L230.Lanexa-NorthernNeck.2208A</Name>
    <LastEdit Timestamp="2025-09-03T10:44:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="230 KV" b3="21292208" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LANEXA" b2="230 KV" b3="220832" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="230 KV" b3="20762208" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NRTHNECK" b2="230 KV" b3="220852" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANEXA" b2="230 KV" b3="LAN-NRTH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103678</SeqNum>
    <Name>L138.Galion-Hamilton-Selma</Name>
    <LastEdit Timestamp="2025-09-18T09:01:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02HAMILT" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GALION" b2="138 KV" b3="GAL-02H2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02HAMILT" b2="138 KV" b3="LD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="55" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="B56" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SELMA2" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SELMA2" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="02HAMILT" b2="138 KV" b3="HAM-SELM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103679</SeqNum>
    <Name>L138.Selma-DualRail-Roberts</Name>
    <LastEdit Timestamp="2025-09-18T09:01:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="02DUALRT" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="02DUALRT" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ROBERTOE" b2="138 KV" b3="ROB-02D1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02DUALRT" b2="138 KV" b3="TR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="02DUALRT" b2="138 KV" b3="YACHIYO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBERTOE" b2="138 KV" b3="B60" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROBERTOE" b2="138 KV" b3="D54" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SELMA2" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SELMA2" b2="138 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="02DUALRT" b2="138 KV" b3="DUA-SELM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103682</SeqNum>
    <Name>L69.EastFork-Wilmington</Name>
    <LastEdit Timestamp="2025-09-12T15:44:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EASTFORK" b2="69 KV" b3="EAS-WILM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTFORK" b2="69 KV" b3="HS3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EASTFORK" b2="69 KV" b3="HS4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILMING2" b2="69 KV" b3="5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103683</SeqNum>
    <Name>L345.PrinceTown-NewScotland</Name>
    <LastEdit Timestamp="2025-09-18T08:55:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWSCOTL" b2="345 KV" b3="R361" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINCTWN" b2="345 KV" b3="G210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRINCTWN" b2="345 KV" b3="G220" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWSCOTL" b2="345 KV" b3="NEW-PR61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103686</SeqNum>
    <Name>L69.Harrisburg-NHarrisburg-Gibson.2</Name>
    <LastEdit Timestamp="2025-09-16T14:42:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON" b2="69 KV" b3="COP2CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON" b2="69 KV" b3="COPP2" />
      <ContingencyEquipment Action="L" Type="LN" b1="GIBSON" b2="69 KV" b3="GIB-NHA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARRISBU" b2="69 KV" b3="HUMM_2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HARRISBU" b2="69 KV" b3="TRAN3" />
      <ContingencyEquipment Action="L" Type="LN" b1="HARRISBU" b2="69 KV" b3="HAR-NHA2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NHARRISB" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103687</SeqNum>
    <Name>L69.Gibson-AP1-Oberlin-AP2-Ebenezer-Hummel.2</Name>
    <LastEdit Timestamp="2025-09-18T12:57:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="AMPPARK1" b2="69 KV" b3="AP1-OBE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMPPARK1" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="AMPPARK1" b2="69 KV" b3="TRAN1-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMPPARK2" b2="69 KV" b3="AP2-EBE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="AMPPARK2" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="AMPPARK2" b2="69 KV" b3="TRAN1-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="EBENEZR" b2="69 KV" b3="EBE-HUM2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="EBENEZR" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMPPARK1" b2="69 KV" b3="AMP-GIB2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON" b2="69 KV" b3="HUM2WSH1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON" b2="69 KV" b3="HUMM2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HUMMELST" b2="69 KV" b3="HARR_2-W" />
      <ContingencyEquipment Action="L" Type="LN" b1="AMPPARK2" b2="69 KV" b3="AP2-OBE" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OBRLINPL" b2="69 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103693</SeqNum>
    <Name>L69.Quarry-Nazareth.1</Name>
    <LastEdit Timestamp="2025-09-24T14:45:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COPLAY1" b2="69 KV" b3="COP-COP1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COPLAY1" b2="69 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COPLAY2" b2="69 KV" b3="CO2-NAZ1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COPLAY2" b2="69 KV" b3="COP2-1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COPLAY2" b2="69 KV" b3="LOST1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COPLAY1" b2="69 KV" b3="COP-FAR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRMRSVPL" b2="69 KV" b3="TRAN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="QUA1SIE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="QUAR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="69 KV" b3="NAZA1_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="69 KV" b3="NAZA1_S" />
      <ContingencyEquipment Action="L" Type="LN" b1="QUARRY" b2="69 KV" b3="QUA-SFA" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRMRSVPL" b2="69 KV" b3="FAR-SFA" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SFARMERS" b2="69 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103694</SeqNum>
    <Name>L138.Huffman-Wildwood-JacksonsFerry</Name>
    <LastEdit Timestamp="2025-09-30T16:04:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HUFFMAN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="HUFFMAN" b2="138 KV" b3="HUF-WILD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="P" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JACKSONS" b2="138 KV" b3="P2" />
      <ContingencyEquipment Action="L" Type="LN" b1="JACKSONS" b2="138 KV" b3="JAC-WILD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WILDWOOD" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103695</SeqNum>
    <Name>L230.Pioneer-Sandlot.2220A</Name>
    <LastEdit Timestamp="2026-02-11T13:12:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PIONEER1" b2="230 KV" b3="21872220" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PIONEER1" b2="230 KV" b3="222092" />
      <ContingencyEquipment Action="L" Type="LN" b1="PIONEER1" b2="230 KV" b3="PIO-SAND" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDLOT" b2="230 KV" b3="22202243" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDLOT" b2="230 KV" b3="222042" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANDLOT" b2="230 KV" b3="YT2220" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103696</SeqNum>
    <Name>L69.Vineland.0711-2SD</Name>
    <LastEdit Timestamp="2025-09-23T12:37:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="S" Type="SD" b1="VINELAND" b2="69 KV" b3="0711-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINELAND" b2="69 KV" b3="OCB F" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINELAND" b2="69 KV" b3="OCB S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINELAND" b2="69 KV" b3="OCB U" />
      <ContingencyEquipment Action="OP" Type="CB" b1="VINELAND" b2="69 KV" b3="T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103697</SeqNum>
    <Name>DTX138.Horizon.T1 (AEP)</Name>
    <LastEdit Timestamp="2025-09-23T13:36:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON" b2="138 KV" b3="H012C5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON" b2="138 KV" b3="H012C8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HORIZON" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103698</SeqNum>
    <Name>DTX138.Horizon.T2 (AEP)</Name>
    <LastEdit Timestamp="2025-09-23T13:37:47" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON" b2="138 KV" b3="H012D5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON" b2="138 KV" b3="H012D8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HORIZON" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103699</SeqNum>
    <Name>DTX138.Horizon.T6 (AEP)</Name>
    <LastEdit Timestamp="2025-09-23T13:38:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON" b2="138 KV" b3="H012F2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HORIZON" b2="138 KV" b3="H012F5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HORIZON" b2="138 KV" b3="T6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103700</SeqNum>
    <Name>L69.Nazareth-KeystoneCement.1 (Protection)</Name>
    <LastEdit Timestamp="2026-05-15T15:38:56" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTCEM" b2="69 KV" b3="1453" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEYSTCEM" b2="69 KV" b3="1453_BYP" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEYSTCEM" b2="69 KV" b3="KEY-NAZ1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="MAC2SIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="SIEG1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103701</SeqNum>
    <Name>L69.Siegfried-KeystoneCement-Nazareth.2(sw/bypass)</Name>
    <LastEdit Timestamp="2026-05-26T10:36:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEYSTCEM" b2="69 KV" b3="1562" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEYSTCEM" b2="69 KV" b3="1563" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEYSTCEM" b2="69 KV" b3="KEY-SIE2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEYSTCEM" b2="69 KV" b3="SUB1_LD2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEYSTCEM" b2="69 KV" b3="SUB2_LD2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEYSTCEM" b2="69 KV" b3="KEY-NAZ2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="QUA1SIE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="SIEG2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="NAZ2FRC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="NAZA2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103702</SeqNum>
    <Name>L69.Quarry-Farmersville-Coplay-Nazareth.2 </Name>
    <LastEdit Timestamp="2025-10-27T10:16:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="COPLAY1" b2="69 KV" b3="COP-COP2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COPLAY1" b2="69 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="COPLAY2" b2="69 KV" b3="CO2-NAZ2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COPLAY2" b2="69 KV" b3="COP2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COPLAY2" b2="69 KV" b3="COP2-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="COPLAY2" b2="69 KV" b3="LONESTAR" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="COPLAY2" b2="69 KV" b3="LOST1" />
      <ContingencyEquipment Action="L" Type="LN" b1="COPLAY1" b2="69 KV" b3="COP-FAR2" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRMRSVPL" b2="69 KV" b3="FAR-SFA2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FRMRSVPL" b2="69 KV" b3="TRAN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="MAC1QUA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="QUAR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="69 KV" b3="NAZA2_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUARRY" b2="69 KV" b3="NAZA2_S" />
      <ContingencyEquipment Action="L" Type="LN" b1="QUARRY" b2="69 KV" b3="QUA-SFA2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SFARMERS" b2="69 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103703</SeqNum>
    <Name>69/13.Hanover.T1</Name>
    <LastEdit Timestamp="2025-09-30T16:19:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANOVER" b2="69 KV" b3="66407" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANOVER" b2="69 KV" b3="66410" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANOVER" b2="69 KV" b3="66413" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANOVER" b2="69 KV" b3="HAN-PAR" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANOVER" b2="69 KV" b3="HAN-PLY" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HANOVER" b2="13 KV" b3="LOAD1" />
      <ContingencyEquipment Action="X" Type="XF" b1="HANOVER" b2="69 KV" b3="XFMR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103704</SeqNum>
    <Name>69/13.Hanover.T2</Name>
    <LastEdit Timestamp="2025-09-30T16:19:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="HANOVER" b2="69 KV" b3="66404" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HANOVER" b2="69 KV" b3="66407" />
      <ContingencyEquipment Action="L" Type="LN" b1="HANOVER" b2="69 KV" b3="HAN-LOO" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HANOVER" b2="13 KV" b3="LOAD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HANOVER" b2="69 KV" b3="XFMR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103705</SeqNum>
    <Name>L230.Doubs-Quantum</Name>
    <LastEdit Timestamp="2025-09-30T20:50:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ14 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ15 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUANT400" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUANT400" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBS" b2="230 KV" b3="DOU-QUA2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103706</SeqNum>
    <Name>L230.Quantum-LimeKiln</Name>
    <LastEdit Timestamp="2025-09-30T20:49:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMEKILN" b2="230 KV" b3="DOUBS231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUANT400" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUANT400" b2="230 KV" b3="B4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUANT400" b2="230 KV" b3="B8" />
      <ContingencyEquipment Action="L" Type="LN" b1="LIMEKILN" b2="230 KV" b3="LIM-QUAN" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103709</SeqNum>
    <Name>DTX138.RollingMill.AirGas (PE)</Name>
    <LastEdit Timestamp="2026-04-21T15:31:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ROLL PE" b2="138 KV" b3="AIRGAS" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="ROLL PE" b2="138 KV" b3="DUM1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103711</SeqNum>
    <Name>TEMP:L500.Bismark-Doubs &amp; Doubs.500.Cap4</Name>
    <LastEdit Timestamp="2025-10-09T10:40:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BISMARK" b2="500 KV" b3="551T583" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBS" b2="500 KV" b3="583" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISMARK" b2="500 KV" b3="58342" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DOUBS" b2="500 KV" b3="CAP4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="CB 50" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="CB 53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="500 KV" b3="DL61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103718</SeqNum>
    <Name>L765.Dumont-Sorenson</Name>
    <LastEdit Timestamp="2025-10-21T14:42:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="765 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="765 KV" b3="A2_CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUMONT2" b2="765 KV" b3="DUM-SOR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUMONT2" b2="765 KV" b3="RA2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DUMONT2" b2="765 KV" b3="RXFD" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DUMONT2" b2="765 KV" b3="RXFE" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DUMONT2" b2="765 KV" b3="RXFF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="765 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SORENSON" b2="765 KV" b3="J2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103720</SeqNum>
    <Name>L345.Elderberry-Larrison</Name>
    <LastEdit Timestamp="2025-12-12T15:36:34" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDERBER" b2="345 KV" b3="A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ELDERBER" b2="345 KV" b3="B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="ELDERBER" b2="345 KV" b3="ELD-LARR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008D5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103721</SeqNum>
    <Name>L138.Guardian-McNutt</Name>
    <LastEdit Timestamp="2025-10-21T14:48:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GUARDIAN" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="L" Type="LN" b1="GUARDIAN" b2="138 KV" b3="GUA-MCNU" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GUARDIAN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCNUTT" b2="138 KV" b3="M008Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCNUTT" b2="138 KV" b3="M009E8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103722</SeqNum>
    <Name>DTX138.RedLion.T2</Name>
    <LastEdit Timestamp="2025-12-18T17:20:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="130" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REDLION" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="REDLION" b2="138 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103725</SeqNum>
    <Name>L230.NewPost-SummDP-LeesHillDP.2355</Name>
    <LastEdit Timestamp="2026-02-11T13:09:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESHILL" b2="230 KV" b3="235522" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEESHILL" b2="230 KV" b3="LEE-SUMM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESHILL" b2="230 KV" b3="WT2355" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPOST" b2="230 KV" b3="209052-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEWPOST" b2="230 KV" b3="235552-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUMMITDP" b2="230 KV" b3="DP" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWPOST" b2="230 KV" b3="NEW-SUMM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103726</SeqNum>
    <Name>McNutt.ElkharSP</Name>
    <LastEdit Timestamp="2025-10-24T12:56:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="MCNUTT" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MCNUTT" b2="34.5 KV" b3="ELKHARSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="MCNUTT" b2="138 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCNUTT" b2="138 KV" b3="M009E5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MCNUTT" b2="138 KV" b3="M009E8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103727</SeqNum>
    <Name>L138.Kitzmiller-MtZion-Beryl-WestVaco-CrossSchool</Name>
    <LastEdit Timestamp="2025-10-24T13:04:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BERYL" b2="138 KV" b3="BER-MTZ" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERYL" b2="138 KV" b3="BER-CRS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSSCH" b2="138 KV" b3="CS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CROSSSCH" b2="138 KV" b3="CS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITZMILR" b2="138 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITZMILR" b2="138 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="KITZMILR" b2="138 KV" b3="KIT-MTZI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTZI APS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="L" Type="LN" b1="BERYL" b2="138 KV" b3="BER-WES" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTVACO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTVACO" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WESTVACO" b2="138 KV" b3="WVACO G1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="WESTVACO" b2="138 KV" b3="WVACO G2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103728</SeqNum>
    <Name>Kitzmiller.BackboneSP</Name>
    <LastEdit Timestamp="2025-10-22T10:53:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KITZMILR" b2="34.5 KV" b3="BACKBNCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="KITZMILR" b2="34.5 KV" b3="BACKBNSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="KITZMILR" b2="138 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KITZMILR" b2="138 KV" b3="GSU_H_CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103730</SeqNum>
    <Name>DTX115.Westgate.T2 </Name>
    <LastEdit Timestamp="2026-05-08T15:08:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTGATE" b2="115 KV" b3="2 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTGATE" b2="115 KV" b3="B31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTGATE" b2="115 KV" b3="B96712" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103731</SeqNum>
    <Name>DTX115.Westgate.T1 </Name>
    <LastEdit Timestamp="2026-05-08T15:08:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WESTGATE" b2="115 KV" b3="1 BANK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTGATE" b2="115 KV" b3="B31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WESTGATE" b2="115 KV" b3="B96612" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103733</SeqNum>
    <Name>L138.ClinchRiver-SextonSS-Dickens-WestKingsport</Name>
    <LastEdit Timestamp="2025-10-24T10:03:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLINCHRI" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CLINCHRI" b2="138 KV" b3="CLI-SEX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DICKENS" b2="138 KV" b3="DIC-SEX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DICKENS" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WKINGSPO" b2="138 KV" b3="A007W2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WKINGSPO" b2="138 KV" b3="N" />
      <ContingencyEquipment Action="L" Type="LN" b1="SEXTONSS" b2="138 KV" b3="SEX-WKI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103734</SeqNum>
    <Name>L138.WestKingsport-Moreland </Name>
    <LastEdit Timestamp="2025-10-24T10:05:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MORELAND" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WKINGSPO" b2="138 KV" b3="A007X8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WKINGSPO" b2="138 KV" b3="M" />
      <ContingencyEquipment Action="L" Type="LN" b1="MORELAND" b2="138 KV" b3="MOR-WKI" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103735</SeqNum>
    <Name>DTX138.Gobain.T1&amp;T61</Name>
    <LastEdit Timestamp="2025-10-24T13:02:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GOBAIN" b2="138 KV" b3="B47" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOBAIN" b2="138 KV" b3="B48" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOBAIN" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GOBAIN" b2="138 KV" b3="T61" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103736</SeqNum>
    <Name>DTX138.NewPrairie.T1</Name>
    <LastEdit Timestamp="2025-10-24T16:34:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPRAIRIE" b2="345 KV" b3="M008F5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPRAIRIE" b2="345 KV" b3="M008F8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NPRAIRIE" b2="345 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103737</SeqNum>
    <Name>DTX138.NewPrairie.T2</Name>
    <LastEdit Timestamp="2025-10-24T16:35:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPRAIRIE" b2="345 KV" b3="M008G5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPRAIRIE" b2="345 KV" b3="M008G8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NPRAIRIE" b2="345 KV" b3="T2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103738</SeqNum>
    <Name>DTX138.NewPrairie.T3</Name>
    <LastEdit Timestamp="2025-10-24T16:36:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPRAIRIE" b2="345 KV" b3="M008H5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPRAIRIE" b2="345 KV" b3="M008H8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NPRAIRIE" b2="345 KV" b3="T3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103739</SeqNum>
    <Name>DTX138.NewPrairie.T4</Name>
    <LastEdit Timestamp="2025-10-24T16:36:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NPRAIRIE" b2="345 KV" b3="M008J5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPRAIRIE" b2="345 KV" b3="M008J8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NPRAIRIE" b2="345 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103742</SeqNum>
    <Name>DTX230.Yeagertown.TR3</Name>
    <LastEdit Timestamp="2025-10-28T11:37:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="YEAGERTO" b2="230 KV" b3="#3 TX" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YEAGERTO" b2="230 KV" b3="B29" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YEAGERTO" b2="230 KV" b3="B4_TEMP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103746</SeqNum>
    <Name>Cole.PleasantPrairieSP</Name>
    <LastEdit Timestamp="2025-11-06T15:15:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="S" Type="SD" b1="COLE" b2="345 KV" b3="GENLINE" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLE" b2="345 KV" b3="GSU1" />
      <ContingencyEquipment Action="X" Type="XF" b1="COLE" b2="345 KV" b3="GSU2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="345 KV" b3="GSU2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="345 KV" b3="GSUCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COLE" b2="345 KV" b3="H022X2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="COLE" b2="34.5 KV" b3="PLEPRASP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103747</SeqNum>
    <Name>L138.Reedurban-MilesAve</Name>
    <LastEdit Timestamp="2025-10-29T10:36:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILESAVE" b2="138 KV" b3="D" />
      <ContingencyEquipment Action="L" Type="LN" b1="MILESAVE" b2="138 KV" b3="MIL-REE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REEDURBA" b2="138 KV" b3="H007D2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103748</SeqNum>
    <Name>DTX138.111ElectricJunction.TR79</Name>
    <LastEdit Timestamp="2025-10-29T16:45:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="111 ELEC" b2="138 KV" b3="TR79" />
      <ContingencyEquipment Action="OP" Type="CB" b1="111 ELEC" b2="34.5 KV" b3="TR79_CB" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="111 ELEC" b2="138 KV" b3="TR79_M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103749</SeqNum>
    <Name>345/138.RobisonPark.T6</Name>
    <LastEdit Timestamp="2025-10-30T06:59:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBISONP" b2="138 KV" b3="H4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103750</SeqNum>
    <Name>L138.Corbin-Putnam (IP/MISO)</Name>
    <LastEdit Timestamp="2025-10-30T11:09:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRBN" b2="138 KV" b3="CRB-PUTN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRBN" b2="138 KV" b3="H43" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRBN" b2="138 KV" b3="H45" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PUTN" b2="138 KV" b3="H63" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103751</SeqNum>
    <Name>L138.Corbin-Oglesby.1 (IP/MISO)</Name>
    <LastEdit Timestamp="2025-12-11T15:33:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRBN" b2="138 KV" b3="CRB-OGL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRBN" b2="138 KV" b3="H11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRBN" b2="138 KV" b3="H13" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OGLESBY" b2="138 KV" b3="LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103753</SeqNum>
    <Name>138/69.Dewey.T1</Name>
    <LastEdit Timestamp="2025-11-05T19:08:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="DEWEY" b2="138 KV" b3="1-T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEWEY" b2="69 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEWEY" b2="138 KV" b3="A003L5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEWEY" b2="69 KV" b3="A003M2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="DEWEY" b2="69 KV" b3="CAPAA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103754</SeqNum>
    <Name>DTX230.Yeagertown.T1</Name>
    <LastEdit Timestamp="2025-11-03T11:15:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="YEAGERTO" b2="230 KV" b3="B20" />
      <ContingencyEquipment Action="OP" Type="CB" b1="YEAGERTO" b2="230 KV" b3="B4_TEMP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="YEAGERTO" b2="230 KV" b3="NO.1 T" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103755</SeqNum>
    <Name>L69.MartinsCreek-CherryHill.1(Protection)</Name>
    <LastEdit Timestamp="2026-02-02T09:55:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHERRYHI" b2="69 KV" b3="CB1205" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHERRYHI" b2="69 KV" b3="CHE-MTBE" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARTINSC" b2="69 KV" b3="MAR-MTBE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="69 KV" b3="NAZA1_E" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="69 KV" b3="NAZA1_W" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MTBETHEL" b2="69 KV" b3="T2LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103756</SeqNum>
    <Name>L69.CherryHill-Nazareth.1(Protection)</Name>
    <LastEdit Timestamp="2026-02-02T09:54:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHERRYHI" b2="69 KV" b3="CB1205" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHERRYHI" b2="69 KV" b3="CHE-NAZ1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHERRYHI" b2="69 KV" b3="HERCLOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHERRYHI" b2="69 KV" b3="T1LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="MAC1QUA2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="MACR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103760</SeqNum>
    <Name>LarrabeeRoad-MerrillRoad-Nece HVDC (NENB)</Name>
    <LastEdit Timestamp="2025-11-05T11:17:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LARABERD" b2="345 KV" b3="K3007-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARABERD" b2="345 KV" b3="K3007-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARABERD" b2="345 KV" b3="K3007-5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LARABERD" b2="345 KV" b3="NECE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103761</SeqNum>
    <Name>L138.IndianRiver.13747Span</Name>
    <LastEdit Timestamp="2025-11-05T12:18:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="134" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="135" />
      <ContingencyEquipment Action="S" Type="SD" b1="INDIANRI" b2="138 KV" b3="13747" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="142" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103762</SeqNum>
    <Name>L138.IndianRiver.13746Span</Name>
    <LastEdit Timestamp="2025-11-05T12:18:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="131" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="132" />
      <ContingencyEquipment Action="S" Type="SD" b1="INDIANRI" b2="138 KV" b3="13746" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INDIANRI" b2="138 KV" b3="141" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103763</SeqNum>
    <Name>L138.Boundary-DardenRoad-SouthBend</Name>
    <LastEdit Timestamp="2025-11-07T09:55:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOUNDARY" b2="138 KV" b3="M003G8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOUNDARY" b2="138 KV" b3="M003H5" />
      <ContingencyEquipment Action="L" Type="LN" b1="BOUNDARY" b2="138 KV" b3="BOU-DARD" />
      <ContingencyEquipment Action="L" Type="LN" b1="DARDENRO" b2="138 KV" b3="DAR-SBE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DARDENRO" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DARDENRO" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SBENDAEP" b2="138 KV" b3="C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103764</SeqNum>
    <Name>138/69.Boundary.TR2</Name>
    <LastEdit Timestamp="2025-11-07T09:58:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BOUNDARY" b2="138 KV" b3="M003H5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOUNDARY" b2="138 KV" b3="M003H8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOUNDARY" b2="69 KV" b3="M003K5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BOUNDARY" b2="69 KV" b3="M003L2" />
      <ContingencyEquipment Action="X" Type="XF" b1="BOUNDARY" b2="138 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103765</SeqNum>
    <Name>L230.Wakeman-WintersBranch.2224A</Name>
    <LastEdit Timestamp="2026-01-21T15:43:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKEMN" b2="230 KV" b3="222412" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WAKEMN" b2="230 KV" b3="UT2224" />
      <ContingencyEquipment Action="L" Type="LN" b1="WAKEMN" b2="230 KV" b3="WAK-WINT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERSB" b2="230 KV" b3="22242238" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERSB" b2="230 KV" b3="222472" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103766</SeqNum>
    <Name>DTX138.Dowling.Pivot1</Name>
    <LastEdit Timestamp="2025-11-10T10:17:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="138 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="138 KV" b3="B11" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOWLING" b2="138 KV" b3="PIVOT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103767</SeqNum>
    <Name>DTX138.Dowling.Pivot2</Name>
    <LastEdit Timestamp="2025-11-10T10:19:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="138 KV" b3="B120" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOWLING" b2="138 KV" b3="B130" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DOWLING" b2="138 KV" b3="PIVOT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103768</SeqNum>
    <Name>L138.Timet-KeraLakes1</Name>
    <LastEdit Timestamp="2025-11-10T19:11:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KERALAKE" b2="138 KV" b3="A008D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERALAKE" b2="138 KV" b3="A008D5" />
      <ContingencyEquipment Action="L" Type="LN" b1="KERALAKE" b2="138 KV" b3="KER-TIM1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMET" b2="138 KV" b3="PMB1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103773</SeqNum>
    <Name>DTX138.Cyprus.Cobble4H</Name>
    <LastEdit Timestamp="2026-02-10T09:45:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CYPRUS" b2="138 KV" b3="COBBLE4H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H018A5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H018A8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103776</SeqNum>
    <Name>L230.LeesHillDP-MineRd-Fredericksburg.2301</Name>
    <LastEdit Timestamp="2026-02-11T13:04:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRDRKSBG" b2="230 KV" b3="20832301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRDRKSBG" b2="230 KV" b3="230142" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRDRKSBG" b2="230 KV" b3="FRD-MINE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESHILL" b2="230 KV" b3="230122" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEESHILL" b2="230 KV" b3="LEE-MINE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESHILL" b2="230 KV" b3="YT2301" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINEROAD" b2="230 KV" b3="H112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MINEROAD" b2="230 KV" b3="H212" />
      <ContingencyEquipment Action="X" Type="XF" b1="MINEROAD" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MINEROAD" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MINEROAD" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MINEROAD" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103777</SeqNum>
    <Name>DTX230.LeesHillDP.LDU24</Name>
    <LastEdit Timestamp="2025-11-17T09:35:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEESHILL" b2="230 KV" b3="LD_U24" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESHILL" b2="230 KV" b3="WT2355" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESHILL" b2="230 KV" b3="YT2301" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103778</SeqNum>
    <Name>DTX230.LeesHillDP.LDV24</Name>
    <LastEdit Timestamp="2025-11-17T09:36:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESHILL" b2="230 KV" b3="230122" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESHILL" b2="230 KV" b3="235522" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LEESHILL" b2="230 KV" b3="LD_V24" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103779</SeqNum>
    <Name>L138.Timet-KeraLakes2</Name>
    <LastEdit Timestamp="2025-11-17T11:06:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KERALAKE" b2="138 KV" b3="A008D8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KERALAKE" b2="138 KV" b3="A008E2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KERALAKE" b2="138 KV" b3="KER-TIM2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIMET" b2="138 KV" b3="PMB2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103780</SeqNum>
    <Name>L138.Itasca-W469.10103</Name>
    <LastEdit Timestamp="2026-02-19T13:21:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="101 ITAS" b2="138 KV" b3="IT3-W469" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="L10103CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W-469" b2="138 KV" b3="BT1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W-469" b2="138 KV" b3="BT2-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103783</SeqNum>
    <Name>L138.Zodiac-Lincoln.1</Name>
    <LastEdit Timestamp="2025-12-05T14:34:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN2" b2="138 KV" b3="I" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLN2" b2="138 KV" b3="LIN-ZOD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008N2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008N5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103784</SeqNum>
    <Name>L138.Zodiac-Lincoln.2</Name>
    <LastEdit Timestamp="2025-11-19T13:30:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN2" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLN2" b2="138 KV" b3="LIN-ZOD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008M2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008M5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103787</SeqNum>
    <Name>L69.MartinsCreek-CherryHill.2(Protection)</Name>
    <LastEdit Timestamp="2026-02-02T09:55:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHERRYHI" b2="69 KV" b3="CB1206" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHERRYHI" b2="69 KV" b3="CHE-FACT" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FACTORYV" b2="69 KV" b3="T1LOAD" />
      <ContingencyEquipment Action="L" Type="LN" b1="FACTORYV" b2="69 KV" b3="FAC-MART" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="69 KV" b3="NAZA2CTG" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARTINSC" b2="69 KV" b3="NAZA2_W" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103788</SeqNum>
    <Name>L69.CherryHill-Nazareth.2(Protection)</Name>
    <LastEdit Timestamp="2026-02-02T09:55:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHERRYHI" b2="69 KV" b3="CB1206" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHERRYHI" b2="69 KV" b3="CHE-NAZ2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHERRYHI" b2="69 KV" b3="LICALOAD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CHERRYHI" b2="69 KV" b3="T2LOAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="MAC2SIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="MACR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103789</SeqNum>
    <Name>DTX115.Werner.BK1</Name>
    <LastEdit Timestamp="2025-11-20T09:12:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="WERNER" b2="115 KV" b3="B105" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WERNER" b2="115 KV" b3="B20" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WERNER" b2="115 KV" b3="BK1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103790</SeqNum>
    <Name>L230.AllenCreek-Cloud.2329</Name>
    <LastEdit Timestamp="2026-01-06T11:21:47" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="232942" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENCRK" b2="230 KV" b3="ALL-CLOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="ZT2329" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="232922-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="232922-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103791</SeqNum>
    <Name>L230.AllenCreek-Finneywood.2258</Name>
    <LastEdit Timestamp="2026-01-06T11:21:52" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="225842" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENCRK" b2="230 KV" b3="ALL-FINN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="UT2258" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINNEYWD" b2="230 KV" b3="22582299" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINNEYWD" b2="230 KV" b3="225872" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103807</SeqNum>
    <Name>Sullivan.TradePost.SP</Name>
    <LastEdit Timestamp="2026-06-03T14:47:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="345 KV" b3="345-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SULLIVA2" b2="345 KV" b3="345-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SULLIVA2" b2="345 KV" b3="GSU1" />
      <ContingencyEquipment Action="X" Type="XF" b1="SULLIVA2" b2="345 KV" b3="GSU2" />
      <ContingencyEquipment Action="U" Type="GEN" b1="SULLIVA2" b2="34.5 KV" b3="TRADEPSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103809</SeqNum>
    <Name>L345.Tristate-MercerBottom</Name>
    <LastEdit Timestamp="2025-12-03T13:21:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCERSB" b2="345 KV" b3="A008F5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCERSB" b2="345 KV" b3="A008F8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="345 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRISTATE" b2="345 KV" b3="G1" />
      <ContingencyEquipment Action="L" Type="LN" b1="MERCERSB" b2="345 KV" b3="MER-TRIS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103813</SeqNum>
    <Name>Ridgeway.138.RX3.SD</Name>
    <LastEdit Timestamp="2025-12-17T16:59:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGEWAY" b2="138 KV" b3="A002D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RIDGEWAY" b2="138 KV" b3="E" />
      <ContingencyEquipment Action="S" Type="SD" b1="RIDGEWAY" b2="138 KV" b3="RX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103814</SeqNum>
    <Name>DTX230.Quantum400.BAUXITE1</Name>
    <LastEdit Timestamp="2025-12-08T14:32:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="QUANT400" b2="230 KV" b3="B2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUANT400" b2="230 KV" b3="B3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="QUANT400" b2="230 KV" b3="BAUXITE1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="QUANT400" b2="230 KV" b3="D38" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103815</SeqNum>
    <Name>DTX230.Quantum400.BAUXITE2</Name>
    <LastEdit Timestamp="2025-12-08T14:32:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="QUANT400" b2="230 KV" b3="B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUANT400" b2="230 KV" b3="B6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="QUANT400" b2="230 KV" b3="BAUXITE2" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="QUANT400" b2="230 KV" b3="D40" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103816</SeqNum>
    <Name>DTX345.MercersBottom.NUCOR1</Name>
    <LastEdit Timestamp="2026-01-20T12:18:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCERSB" b2="345 KV" b3="A008F2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCERSB" b2="345 KV" b3="A008F5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MERCERSB" b2="345 KV" b3="NUCOR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103817</SeqNum>
    <Name>DTX345.MercersBottom.NUCOR2</Name>
    <LastEdit Timestamp="2026-01-20T12:20:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCERSB" b2="345 KV" b3="A008G5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MERCERSB" b2="345 KV" b3="A008G8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MERCERSB" b2="345 KV" b3="NUCOR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103818</SeqNum>
    <Name>L345.Celtic-HyattCS</Name>
    <LastEdit Timestamp="2025-12-17T11:33:44" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="345 KV" b3="H021A8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="345 KV" b3="H021J5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="345 KV" b3="H021J8" />
      <ContingencyEquipment Action="L" Type="LN" b1="CELTIC" b2="345 KV" b3="CEL-HYAT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HYATTCS" b2="345 KV" b3="H2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103820</SeqNum>
    <Name>Fermi.U2 (DET/MISO)</Name>
    <LastEdit Timestamp="2025-12-10T20:06:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="EFERMI" b2="345 KV" b3="CF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EFERMI" b2="345 KV" b3="CM" />
      <ContingencyEquipment Action="U" Type="GEN" b1="EFERMI" b2="22 KV" b3="FE2" />
      <ContingencyEquipment Action="X" Type="XF" b1="EFERMI" b2="345 KV" b3="G2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103821</SeqNum>
    <Name>RAS.L230.Bremo-Buckingham-Farmville.298+Clover.U2</Name>
    <LastEdit Timestamp="2026-02-11T06:44:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="230 KV" b3="29822" />
      <ContingencyEquipment Action="L" Type="LN" b1="BREMO4" b2="230 KV" b3="298A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BREMO4" b2="230 KV" b3="H722" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUCKNGHM" b2="230 KV" b3="298B" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BUCKNGHM" b2="35 KV" b3="BUCKN2SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="BUCKNGHM" b2="35 KV" b3="BUCKNMSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUCKNGHM" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUCKNGHM" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="BUCKNGHM" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BUCKNGHM" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="25 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G2TL9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOVER" b2="7 KV" b3="SS2LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="230 KV" b3="235T298" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMVILL" b2="230 KV" b3="H532" />
      <ContingencyEquipment Action="X" Type="XF" b1="FARMVILL" b2="230 KV" b3="TX6" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FARMVILL" b2="35 KV" b3="TX6LOAD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103822</SeqNum>
    <Name>RAS.L230.AllenCreek-Cloud.2329 + Clover.U2</Name>
    <LastEdit Timestamp="2026-02-11T06:44:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="232942" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENCRK" b2="230 KV" b3="ALL-CLOU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="ZT2329" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="232922-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="232922-4" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="25 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G2TL9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOVER" b2="7 KV" b3="SS2LD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103823</SeqNum>
    <Name>RAS.L230.AllenCreek-Finneywood.2258 + Clover.U2</Name>
    <LastEdit Timestamp="2026-02-11T06:44:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="225842" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENCRK" b2="230 KV" b3="ALL-FINN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="UT2258" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLOVER" b2="25 KV" b3="G2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G212" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOVER" b2="230 KV" b3="G2TL9" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOVER" b2="7 KV" b3="SS2LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINNEYWD" b2="230 KV" b3="22582299" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINNEYWD" b2="230 KV" b3="225872" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103825</SeqNum>
    <Name>DTX138.Zodiac.CAPRA</Name>
    <LastEdit Timestamp="2025-12-12T16:28:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ZODIAC" b2="138 KV" b3="CAPRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008S2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008S5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103827</SeqNum>
    <Name>L345.Bermuda-Innovation</Name>
    <LastEdit Timestamp="2026-04-14T15:12:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BERMUDA" b2="345 KV" b3="BER-INNO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERMUDA" b2="345 KV" b3="H021D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERMUDA" b2="345 KV" b3="H021D5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="345 KV" b3="H010Q2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INNOVATI" b2="345 KV" b3="H010Q5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103828</SeqNum>
    <Name>L345.Larrison-NewPrairie</Name>
    <LastEdit Timestamp="2025-12-15T15:41:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LARRISON" b2="345 KV" b3="LAR-NPRA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRISON" b2="345 KV" b3="M008A5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPRAIRIE" b2="345 KV" b3="M008F2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NPRAIRIE" b2="345 KV" b3="M008F5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103831</SeqNum>
    <Name>L69.WestCambridge-MacesLane.6783</Name>
    <LastEdit Timestamp="2025-12-15T13:44:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MACELANE" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACELANE" b2="69 KV" b3="61" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WCAMBRID" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="L" Type="LN" b1="MACELANE" b2="69 KV" b3="MAC-WES" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103833</SeqNum>
    <Name>230/69.NorthHershey.TR5</Name>
    <LastEdit Timestamp="2025-12-16T15:48:38" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NHERSHEY" b2="230 KV" b3="B164" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHERSHEY" b2="230 KV" b3="B92" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHERSHEY" b2="69 KV" b3="B94" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NHERSHEY" b2="69 KV" b3="B95" />
      <ContingencyEquipment Action="X" Type="XF" b1="NHERSHEY" b2="230 KV" b3="TR5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103834</SeqNum>
    <Name>L230.Hayfield-EPG.215</Name>
    <LastEdit Timestamp="2025-12-17T12:10:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EPG" b2="230 KV" b3="226452" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EPG" b2="230 KV" b3="H12T2264" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYFIEL4" b2="230 KV" b3="226442" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAYFIEL4" b2="230 KV" b3="241T2264" />
      <ContingencyEquipment Action="L" Type="LN" b1="EPG" b2="230 KV" b3="HAY-EPG" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103836</SeqNum>
    <Name>L115.Franklin-Vernon.D931</Name>
    <LastEdit Timestamp="2025-12-17T16:14:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLIN" b2="115 KV" b3="B39" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRANKLIN" b2="115 KV" b3="B40" />
      <ContingencyEquipment Action="L" Type="LN" b1="FRANKLIN" b2="115 KV" b3="FRA-VERD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="VERNON" b2="115 KV" b3="BK 4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103837</SeqNum>
    <Name>L138.Ebersole-RockyFord</Name>
    <LastEdit Timestamp="2025-12-17T19:41:19" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="EBERSOLE" b2="138 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EBERSOLE" b2="138 KV" b3="C1" />
      <ContingencyEquipment Action="L" Type="LN" b1="EBERSOLE" b2="138 KV" b3="EBE-ROCK" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKYFOR" b2="138 KV" b3="H021Q5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKYFOR" b2="138 KV" b3="H021U2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103838</SeqNum>
    <Name>DTX230.AllenCreek. LDZ</Name>
    <LastEdit Timestamp="2025-12-18T12:17:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLENCRK" b2="230 KV" b3="LDZ" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="Z42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="ZT2329" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103839</SeqNum>
    <Name>DTX230.AllenCreek. LDU</Name>
    <LastEdit Timestamp="2025-12-18T12:19:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLENCRK" b2="230 KV" b3="LDU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="U42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="UT2258" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103840</SeqNum>
    <Name>DTX230.AllenCreek. LDV</Name>
    <LastEdit Timestamp="2025-12-18T12:22:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLENCRK" b2="230 KV" b3="LDV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="V42" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="VTW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103841</SeqNum>
    <Name>DTX230.AllenCreek. LDY</Name>
    <LastEdit Timestamp="2025-12-18T12:24:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ALLENCRK" b2="230 KV" b3="LDY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="XTY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENCRK" b2="230 KV" b3="Y42" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103842</SeqNum>
    <Name>L500.Mosby-WishingStar.546</Name>
    <LastEdit Timestamp="2025-12-19T11:55:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSBY" b2="500 KV" b3="502T546" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOSBY" b2="500 KV" b3="54672" />
      <ContingencyEquipment Action="L" Type="LN" b1="MOSBY" b2="500 KV" b3="MOS-WIS2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WISHSTAR" b2="500 KV" b3="54642-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WISHSTAR" b2="500 KV" b3="54642-4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103843</SeqNum>
    <Name>DTX138.Pokagon.T4</Name>
    <LastEdit Timestamp="2026-02-10T09:46:31" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="POKAGON" b2="138 KV" b3="T4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="POKAGON" b2="138 KV" b3="XT4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103846</SeqNum>
    <Name>DTX115.ShadeGap.T1</Name>
    <LastEdit Timestamp="2026-01-21T17:51:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHADEGAP" b2="115 KV" b3="B5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SHADEGAP" b2="115 KV" b3="NO1 TX" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHADEGAP" b2="115 KV" b3="NO1_TX_A" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103848</SeqNum>
    <Name>L138.Dragoon-TwinBranch</Name>
    <LastEdit Timestamp="2025-12-30T13:18:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="DRAGOON" b2="138 KV" b3="DRA-TWI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAGOON" b2="138 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TWINBRAN" b2="138 KV" b3="B1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103849</SeqNum>
    <Name>DTX138.Dragoon.T1</Name>
    <LastEdit Timestamp="2025-12-30T13:18:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DRAGOON" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAGOON" b2="138 KV" b3="XT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103850</SeqNum>
    <Name>DTX138.Dragoon.T2</Name>
    <LastEdit Timestamp="2025-12-30T13:18:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DRAGOON" b2="138 KV" b3="T2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRAGOON" b2="138 KV" b3="XT2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103851</SeqNum>
    <Name>DTX138.GreenChapel.T5</Name>
    <LastEdit Timestamp="2025-12-30T13:20:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008M5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008M8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENCHA" b2="138 KV" b3="T5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103852</SeqNum>
    <Name>DTX138.GreenChapel.T4</Name>
    <LastEdit Timestamp="2025-12-30T13:20:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008L5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008L8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENCHA" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103853</SeqNum>
    <Name>230/115.WilliamsGrove.T3</Name>
    <LastEdit Timestamp="2025-12-30T13:14:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="WILLGROV" b2="230 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLGROV" b2="230 KV" b3="T3_HI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLGROV" b2="115 KV" b3="T3_LO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103855</SeqNum>
    <Name>345/138.Celtic.TR1</Name>
    <LastEdit Timestamp="2026-01-08T09:43:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="138 KV" b3="H020Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="138 KV" b3="H020Z5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="345 KV" b3="H021A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="345 KV" b3="H021J5" />
      <ContingencyEquipment Action="X" Type="XF" b1="CELTIC" b2="345 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103856</SeqNum>
    <Name>345/138.Celtic.TR2</Name>
    <LastEdit Timestamp="2026-01-07T17:10:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="138 KV" b3="H020Y5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="138 KV" b3="H020Y8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="345 KV" b3="H021A5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="345 KV" b3="H021A8" />
      <ContingencyEquipment Action="X" Type="XF" b1="CELTIC" b2="345 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103857</SeqNum>
    <Name>L230.BrickYard-WintersBranch.2239</Name>
    <LastEdit Timestamp="2026-01-06T11:25:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRICKYRD" b2="230 KV" b3="20112239" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRICKYRD" b2="230 KV" b3="223932" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRICKYRD" b2="230 KV" b3="BRI-WIN9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERSB" b2="230 KV" b3="21322239" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERSB" b2="230 KV" b3="223972" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103858</SeqNum>
    <Name>L230.BrickYard-WintersBranch.2238</Name>
    <LastEdit Timestamp="2026-01-20T15:51:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRICKYRD" b2="230 KV" b3="21952238" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRICKYRD" b2="230 KV" b3="223832" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRICKYRD" b2="230 KV" b3="BRI-WIN8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERSB" b2="230 KV" b3="22242238" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WINTERSB" b2="230 KV" b3="223872" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103859</SeqNum>
    <Name>DTX230.Cloud.LD3W25</Name>
    <LastEdit Timestamp="2026-02-11T06:50:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="222922-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="232922-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="H122" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CLOUD" b2="230 KV" b3="LD3W25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CLOUD" b2="230 KV" b3="T352" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103860</SeqNum>
    <Name>L138.Celtic-Jerome.1</Name>
    <LastEdit Timestamp="2026-01-15T08:01:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CELTIC" b2="138 KV" b3="CEL-JERO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="138 KV" b3="H020Y2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="138 KV" b3="H020Y5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEROMEOH" b2="138 KV" b3="H009Z8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEROMEOH" b2="138 KV" b3="H010G2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103861</SeqNum>
    <Name>L138.Celtic-Jerome.2</Name>
    <LastEdit Timestamp="2026-01-15T08:01:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CELTIC" b2="138 KV" b3="CEL-JER2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="138 KV" b3="H020Z5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="138 KV" b3="H020Z8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEROMEOH" b2="138 KV" b3="H010C8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JEROMEOH" b2="138 KV" b3="H010H2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103862</SeqNum>
    <Name>L138.Celtic-Kileville</Name>
    <LastEdit Timestamp="2026-01-20T12:25:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CELTIC" b2="138 KV" b3="CEL-KILE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="138 KV" b3="H021H2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="138 KV" b3="H021H5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KILEVILL" b2="138 KV" b3="H003B5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KILEVILL" b2="138 KV" b3="H003B8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103866</SeqNum>
    <Name>115/34.Flanders.TR1</Name>
    <LastEdit Timestamp="2026-01-16T10:13:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FLANDERS" b2="34.5 KV" b3="B16" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FLANDERS" b2="115 KV" b3="B9" />
      <ContingencyEquipment Action="X" Type="XF" b1="FLANDERS" b2="115 KV" b3="TR1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103868</SeqNum>
    <Name>L230.WhiteOak-DecoyAirfield.2280B</Name>
    <LastEdit Timestamp="2026-01-20T10:28:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DECYARFD" b2="230 KV" b3="228092-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DECYARFD" b2="230 KV" b3="228092-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DECYARFD" b2="230 KV" b3="DEC-WHIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEOA4" b2="230 KV" b3="228042-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHITEOA4" b2="230 KV" b3="228042-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103869</SeqNum>
    <Name>L230.DecoyAirfield-TechPark.2344A</Name>
    <LastEdit Timestamp="2026-01-29T14:13:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DECYARFD" b2="230 KV" b3="234492-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DECYARFD" b2="230 KV" b3="234492-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="DECYARFD" b2="230 KV" b3="DEC-TECH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TECHPARK" b2="230 KV" b3="234412" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TECHPARK" b2="230 KV" b3="286T2344" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103870</SeqNum>
    <Name>Celtic.138.Cap2</Name>
    <LastEdit Timestamp="2026-01-20T10:38:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="CELTIC" b2="138 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="138 KV" b3="H021M5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103871</SeqNum>
    <Name>Celtic.138.Cap1</Name>
    <LastEdit Timestamp="2026-01-20T10:40:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="CELTIC" b2="138 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELTIC" b2="138 KV" b3="H021L8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103872</SeqNum>
    <Name>L230.LincolnPrk-ParkCenter.2242B</Name>
    <LastEdit Timestamp="2026-01-20T10:57:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLNP" b2="230 KV" b3="20082242" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLNP" b2="230 KV" b3="224272" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARKCNTR" b2="230 KV" b3="22422397" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARKCNTR" b2="230 KV" b3="224242" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLNP" b2="230 KV" b3="LIN-PAR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103873</SeqNum>
    <Name>L230.ParkCenter-Dulles.2397A</Name>
    <LastEdit Timestamp="2026-01-21T15:37:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DULLES" b2="230 KV" b3="239782-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DULLES" b2="230 KV" b3="239782-9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARKCNTR" b2="230 KV" b3="22422397" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARKCNTR" b2="230 KV" b3="239742" />
      <ContingencyEquipment Action="L" Type="LN" b1="DULLES" b2="230 KV" b3="DUL-PARK" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103879</SeqNum>
    <Name>L230.CannonBranch-BrickYard.2195A</Name>
    <LastEdit Timestamp="2026-01-21T15:40:49" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRICKYRD" b2="230 KV" b3="21952238" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRICKYRD" b2="230 KV" b3="219532" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRICKYRD" b2="230 KV" b3="BRI-CANN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANNONBR" b2="230 KV" b3="219522" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CANNONBR" b2="230 KV" b3="H1T2195" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103880</SeqNum>
    <Name>DTX230.DecoyAirfield.Z94</Name>
    <LastEdit Timestamp="2026-02-14T10:47:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DECYARFD" b2="230 KV" b3="228092-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DECYARFD" b2="230 KV" b3="234492-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DECYARFD" b2="230 KV" b3="LD_Z94" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103881</SeqNum>
    <Name>DTX230.DecoyAirfield.W94</Name>
    <LastEdit Timestamp="2026-02-14T10:45:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DECYARFD" b2="230 KV" b3="228092-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DECYARFD" b2="230 KV" b3="234492-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="DECYARFD" b2="230 KV" b3="LD_W94" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103882</SeqNum>
    <Name>L115.ShadeGap-HillValley</Name>
    <LastEdit Timestamp="2026-01-21T17:49:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="HILLVALL" b2="115 KV" b3="#1 TX" />
      <ContingencyEquipment Action="L" Type="LN" b1="HILLVALL" b2="115 KV" b3="HIL-SHA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHADEGAP" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHADEGAP" b2="115 KV" b3="HILL_VLY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103885</SeqNum>
    <Name>L115.ChestCrk-Westover.991 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-22T13:28:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTCRK" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTCRK" b2="115 KV" b3="B2" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTCRK" b2="115 KV" b3="CHE-WEST" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WESTOVER" b2="115 KV" b3="MADERAMO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103886</SeqNum>
    <Name>L115.Madera-ChestCrk.991 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-01-22T13:29:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTCRK" b2="115 KV" b3="B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTCRK" b2="115 KV" b3="B3" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHESTCRK" b2="115 KV" b3="CHE-MADE" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="MADERA" b2="115 KV" b3="WSTS MOA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103889</SeqNum>
    <Name>L230.NorthAnna-SouthHall.255C</Name>
    <LastEdit Timestamp="2026-01-22T13:56:26" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="230 KV" b3="25502" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NANNA4" b2="230 KV" b3="H3T255" />
      <ContingencyEquipment Action="L" Type="LN" b1="NANNA4" b2="230 KV" b3="NAN-SOUT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOUTHALL" b2="230 KV" b3="25562-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOUTHALL" b2="230 KV" b3="25562-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103890</SeqNum>
    <Name>L230.SouthHall-Louisa-Desper.2304A</Name>
    <LastEdit Timestamp="2026-05-11T11:36:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DESPER" b2="230 KV" b3="22022304" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DESPER" b2="230 KV" b3="230432" />
      <ContingencyEquipment Action="U" Type="GEN" b1="LOUISA" b2="35 KV" b3="BTM1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOUISA" b2="230 KV" b3="LOU-LOUI" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOUISA" b2="230 KV" b3="LOU-SOUT" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOUISA" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOUISA" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="L" Type="LN" b1="DESPER" b2="230 KV" b3="DES-LOUI" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LOUISAPP" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOUTHALL" b2="230 KV" b3="230462-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOUTHALL" b2="230 KV" b3="230462-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103891</SeqNum>
    <Name>L345.Francisco-Duff[CIN/SIGE]</Name>
    <LastEdit Timestamp="2026-01-28T08:05:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUFF" b2="345 KV" b3="3300" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUFF" b2="345 KV" b3="3600" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRCSCCIN" b2="345 KV" b3="3300" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FRCSCCIN" b2="345 KV" b3="3500" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUFF" b2="345 KV" b3="DUF-FRC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103892</SeqNum>
    <Name>L115.Lincoln-Riley</Name>
    <LastEdit Timestamp="2026-01-28T09:48:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLN" b2="115 KV" b3="96262-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LINCOLN" b2="115 KV" b3="BK3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RILEY" b2="115 KV" b3="B10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RILEY" b2="115 KV" b3="B20" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLN" b2="115 KV" b3="LIN-RILE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103899</SeqNum>
    <Name>L230.Lowmoor-RockyForge.2069 + Lowmoor.TX3 + TX4</Name>
    <LastEdit Timestamp="2026-06-02T12:07:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LOWMOOR" b2="230 KV" b3="2069A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWMOOR" b2="138 KV" b3="L34T112" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOWMOOR" b2="138 KV" b3="L34T161" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOWMOOR" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="X" Type="XF" b1="LOWMOOR" b2="230 KV" b3="TX4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKFORG" b2="230 KV" b3="20692084" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKFORG" b2="230 KV" b3="206962" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103900</SeqNum>
    <Name>L230.Lexington-RockyForge.2084</Name>
    <LastEdit Timestamp="2026-05-18T14:26:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LEXINGTN" b2="230 KV" b3="208402" />
      <ContingencyEquipment Action="L" Type="LN" b1="LEXINGTN" b2="230 KV" b3="2084B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKFORG" b2="230 KV" b3="20692084" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROCKFORG" b2="230 KV" b3="208462" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103922</SeqNum>
    <Name>Grover.WF</Name>
    <LastEdit Timestamp="2026-02-06T08:44:20" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="HAVILAND" b2="34.5 KV" b3="CAP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HAVILAND" b2="34.5 KV" b3="GROVERWF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HAVILAND" b2="138 KV" b3="H003E2" />
      <ContingencyEquipment Action="X" Type="XF" b1="HAVILAND" b2="138 KV" b3="MPT1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103923</SeqNum>
    <Name>DTX138.Cyprus.COBBLE4G + SKID</Name>
    <LastEdit Timestamp="2026-02-10T10:07:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CYPRUS" b2="138 KV" b3="COBBLE4G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H017Z5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CYPRUS" b2="138 KV" b3="H017Z8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CYPRUS" b2="138 KV" b3="SKID" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103924</SeqNum>
    <Name>L138.FifthAvenue-Wilson</Name>
    <LastEdit Timestamp="2026-02-06T12:17:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="FIFTHAVE" b2="138 KV" b3="FIF-WIL1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIFTHAVE" b2="138 KV" b3="H010Z8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIFTHAVE" b2="138 KV" b3="H011A2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONCS" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILSONCS" b2="138 KV" b3="8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103925</SeqNum>
    <Name>EndlessCaverns.BS1&amp;BS2</Name>
    <LastEdit Timestamp="2026-02-06T12:26:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="115 KV" b3="108352" />
      <ContingencyEquipment Action="X" Type="XF" b1="ENDCAVRN" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ENDCAVRN" b2="115 KV" b3="L5T1083" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ENDCAVRN" b2="35 KV" b3="PRSPT1BS" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ENDCAVRN" b2="35 KV" b3="PRSPT2BS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103926</SeqNum>
    <Name>L230.Reston-ParkCenter.2043A</Name>
    <LastEdit Timestamp="2026-02-11T09:59:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PARKCNTR" b2="230 KV" b3="20432279" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARKCNTR" b2="230 KV" b3="204342" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RESTON" b2="230 KV" b3="20152043" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RESTON" b2="230 KV" b3="20432062" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RESTON" b2="230 KV" b3="H362" />
      <ContingencyEquipment Action="L" Type="LN" b1="PARKCNTR" b2="230 KV" b3="PAR-REST" />
      <ContingencyEquipment Action="X" Type="XF" b1="RESTON" b2="230 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RESTON" b2="35 KV" b3="TX3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103927</SeqNum>
    <Name>L230.ParkCenter-LincolnPark.2279A</Name>
    <LastEdit Timestamp="2026-02-13T14:58:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLNP" b2="230 KV" b3="22322279" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LINCOLNP" b2="230 KV" b3="227972" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARKCNTR" b2="230 KV" b3="20432279" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PARKCNTR" b2="230 KV" b3="227942" />
      <ContingencyEquipment Action="L" Type="LN" b1="LINCOLNP" b2="230 KV" b3="LIN-PAR9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103928</SeqNum>
    <Name>L230.Gainesville-Trident.2346A</Name>
    <LastEdit Timestamp="2026-02-06T13:02:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GAINESVL" b2="230 KV" b3="23462222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GAINESVL" b2="230 KV" b3="234692" />
      <ContingencyEquipment Action="L" Type="LN" b1="GAINESVL" b2="230 KV" b3="GAI-TRID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRIDENT" b2="230 KV" b3="234632-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRIDENT" b2="230 KV" b3="234632-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103929</SeqNum>
    <Name>L230.Trident-Atlantic-Linton-Wheeler.2161D</Name>
    <LastEdit Timestamp="2026-02-06T13:04:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ATLNTCDP" b2="230 KV" b3="2161B" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ATLNTCDP" b2="230 KV" b3="DP1LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="LNTNHLDP" b2="230 KV" b3="2161A" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LNTNHLDP" b2="230 KV" b3="DP1LD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRIDENT" b2="230 KV" b3="216132-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TRIDENT" b2="230 KV" b3="216132-2" />
      <ContingencyEquipment Action="L" Type="LN" b1="ATLNTCDP" b2="230 KV" b3="ATL-TRID" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEELER" b2="230 KV" b3="21612174" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHEELER" b2="230 KV" b3="21612182" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103938</SeqNum>
    <Name>L230.Celestial-Mars-Sojourner.2200</Name>
    <LastEdit Timestamp="2026-02-17T10:42:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CELESTIA" b2="230 KV" b3="21372261" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CELESTIA" b2="230 KV" b3="226132" />
      <ContingencyEquipment Action="L" Type="LN" b1="CELESTIA" b2="230 KV" b3="CEL-MARS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARS2" b2="230 KV" b3="L192" />
      <ContingencyEquipment Action="L" Type="LN" b1="MARS2" b2="230 KV" b3="MAR-SOJO" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOJOURNR" b2="230 KV" b3="229262-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOJOURNR" b2="230 KV" b3="229262-2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103939</SeqNum>
    <Name>L69.Siegfried-KeystoneCement.1 (Protection)</Name>
    <LastEdit Timestamp="2026-05-15T15:39:20" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTCEM" b2="69 KV" b3="1453" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEYSTCEM" b2="69 KV" b3="1453_BYP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEYSTCEM" b2="69 KV" b3="1562" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEYSTCEM" b2="69 KV" b3="1563" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEYSTCEM" b2="69 KV" b3="KEY-SIE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEYSTCEM" b2="69 KV" b3="SUB1_LD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEYSTCEM" b2="69 KV" b3="SUB2_LD1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="NAZ1FRC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="NAZA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103940</SeqNum>
    <Name>Marysville.CadenceSP</Name>
    <LastEdit Timestamp="2026-02-15T06:51:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MARYSVI2" b2="34.5 KV" b3="CADEN1SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MARYSVI2" b2="34.5 KV" b3="CADEN2SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MARYSVI2" b2="34.5 KV" b3="CADEN3SP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="345 KV" b3="G" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARYSVI2" b2="345 KV" b3="G1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARYSVI2" b2="345 KV" b3="MPT1" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARYSVI2" b2="345 KV" b3="MPT2" />
      <ContingencyEquipment Action="X" Type="XF" b1="MARYSVI2" b2="345 KV" b3="MPT3" />
      <ContingencyEquipment Action="S" Type="SD" b1="MARYSVI2" b2="345 KV" b3="SD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103942</SeqNum>
    <Name>L230.Buttermilk-Nimbus.2255</Name>
    <LastEdit Timestamp="2026-05-18T14:26:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTTRMLK" b2="230 KV" b3="22032255" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BUTTRMLK" b2="230 KV" b3="225512" />
      <ContingencyEquipment Action="L" Type="LN" b1="BUTTRMLK" b2="230 KV" b3="BUT-NIMB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NIMBUS" b2="230 KV" b3="225532-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NIMBUS" b2="230 KV" b3="225532-6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103943</SeqNum>
    <Name>L230.Farmwell-Nimbus.2260</Name>
    <LastEdit Timestamp="2026-05-18T14:28:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMWELL" b2="230 KV" b3="21902260" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FARMWELL" b2="230 KV" b3="226082" />
      <ContingencyEquipment Action="L" Type="LN" b1="FARMWELL" b2="230 KV" b3="FAR-NIMB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NIMBUS" b2="230 KV" b3="22482260" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NIMBUS" b2="230 KV" b3="226032" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103944</SeqNum>
    <Name>L230.Beaumeade-Interconnection.2152</Name>
    <LastEdit Timestamp="2026-05-18T14:28:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="215292" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BEAUMEAD" b2="230 KV" b3="227T2152" />
      <ContingencyEquipment Action="L" Type="LN" b1="BEAUMEAD" b2="230 KV" b3="BEA-INTE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INTERCON" b2="230 KV" b3="215252-6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INTERCON" b2="230 KV" b3="215252-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103945</SeqNum>
    <Name>L230.Interconnection-Nimbus.2248</Name>
    <LastEdit Timestamp="2026-05-18T14:34:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="INTERCON" b2="230 KV" b3="224852-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="INTERCON" b2="230 KV" b3="224852-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NIMBUS" b2="230 KV" b3="22482260" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NIMBUS" b2="230 KV" b3="224832" />
      <ContingencyEquipment Action="L" Type="LN" b1="INTERCON" b2="230 KV" b3="INT-NIMB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103949</SeqNum>
    <Name>L69.ShelbyCounty-ShelbyIND (Tie)</Name>
    <LastEdit Timestamp="2026-02-18T10:20:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHELBYCO" b2="69 KV" b3="N53-624" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SHELBYCO" b2="69 KV" b3="N53-627" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHLBYIND" b2="69 KV" b3="SHI-SHLC" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHLBYIND" b2="69 KV" b3="612" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SHLBYIND" b2="69 KV" b3="614" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103950</SeqNum>
    <Name>L138.37Natoma-71Higgins.3706 G</Name>
    <LastEdit Timestamp="2026-02-18T12:06:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="37 NATOM" b2="138 KV" b3="3706" />
      <ContingencyEquipment Action="CL" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT2121CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT728 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="37 NATOM" b2="138 KV" b3="BT729_CB" />
      <ContingencyEquipment Action="CL" Type="DIS" b1="71 HIGGI" b2="138 KV" b3="BT723 M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="71 HIGGI" b2="138 KV" b3="BT745 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="71 HIGGI" b2="138 KV" b3="BT756 CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103951</SeqNum>
    <Name>L345.Deedsville-Leesburg (NIPS/CIN)</Name>
    <LastEdit Timestamp="2026-02-19T05:55:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DEEDSVIL" b2="345 KV" b3="18-B1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DEEDSVIL" b2="345 KV" b3="47-18" />
      <ContingencyEquipment Action="L" Type="LN" b1="DEEDSVIL" b2="345 KV" b3="DEE-LEE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESBURG" b2="345 KV" b3="18" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LEESBURG" b2="345 KV" b3="1824" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103952</SeqNum>
    <Name>L115.Robley-Garner-MoonCorner.1078</Name>
    <LastEdit Timestamp="2026-02-24T22:45:32" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GARNERDP" b2="115 KV" b3="GAR-MOON" />
      <ContingencyEquipment Action="L" Type="LN" b1="GARNERDP" b2="115 KV" b3="GAR-ROBL" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GARNERDP" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOONCRNR" b2="115 KV" b3="10591078" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOONCRNR" b2="115 KV" b3="107842" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOONCRNR" b2="115 KV" b3="6542" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOONCRNR" b2="115 KV" b3="65T1059" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBLEY" b2="115 KV" b3="107862" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBLEY" b2="115 KV" b3="65T1078" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103953</SeqNum>
    <Name>L115.Rappahan-WhiteS-Ocran-Lancaster-Robley.65</Name>
    <LastEdit Timestamp="2026-02-24T22:43:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="LANCASTR" b2="115 KV" b3="65B1" />
      <ContingencyEquipment Action="L" Type="LN" b1="LANCASTR" b2="115 KV" b3="LAN-ROBL" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="LANCASTR" b2="115 KV" b3="SC3" />
      <ContingencyEquipment Action="X" Type="XF" b1="LANCASTR" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LANCASTR" b2="13 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="LANCASTR" b2="115 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LANCASTR" b2="35 KV" b3="TX2" />
      <ContingencyEquipment Action="X" Type="XF" b1="LANCASTR" b2="115 KV" b3="TX3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="LANCASTR" b2="35 KV" b3="TX3" />
      <ContingencyEquipment Action="L" Type="LN" b1="OCRAN" b2="115 KV" b3="65A1" />
      <ContingencyEquipment Action="X" Type="XF" b1="OCRAN" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="OCRAN" b2="13.2 KV" b3="TX1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RAPPAHAN" b2="115 KV" b3="65T1021" />
      <ContingencyEquipment Action="L" Type="LN" b1="RAPPAHAN" b2="115 KV" b3="RAP-WHIT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBLEY" b2="115 KV" b3="6562" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBLEY" b2="115 KV" b3="65T1078" />
      <ContingencyEquipment Action="X" Type="XF" b1="WHITESTN" b2="115 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WHITESTN" b2="13 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103955</SeqNum>
    <Name>230/69.Cumberland.T3</Name>
    <LastEdit Timestamp="2026-02-23T12:36:37" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="CUMB PL" b2="230 KV" b3="3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="230 KV" b3="TRAN3_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="230 KV" b3="TRAN3_S" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CUMB PL" b2="69 KV" b3="TRAN_3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103956</SeqNum>
    <Name>ChestCreek.WF</Name>
    <LastEdit Timestamp="2026-05-08T15:07:12" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="CHESTCRK" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTCRK" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTCRK" b2="115 KV" b3="GSUHCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESTCRK" b2="34.5 KV" b3="ROGUEWF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103958</SeqNum>
    <Name>L138.Brookind-Hughs Rd-Charge</Name>
    <LastEdit Timestamp="2026-02-24T09:50:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKIND" b2="138 KV" b3="14M9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BROOKIND" b2="138 KV" b3="14W4" />
      <ContingencyEquipment Action="L" Type="LN" b1="BROOKIND" b2="138 KV" b3="BRO-HUGH" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARGE" b2="138 KV" b3="14B7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CHARGE" b2="138 KV" b3="14M9" />
      <ContingencyEquipment Action="L" Type="LN" b1="CHARGE" b2="138 KV" b3="CHA-HUGH" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103959</SeqNum>
    <Name>MaceLane.EgyptRoad1.SP</Name>
    <LastEdit Timestamp="2026-02-25T08:46:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MACELANE" b2="69 KV" b3="60" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MACELANE" b2="69 KV" b3="63" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MACELANE" b2="34.5 KV" b3="MACESP" />
      <ContingencyEquipment Action="X" Type="XF" b1="MACELANE" b2="69 KV" b3="TF1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103960</SeqNum>
    <Name>Milton.NUMBER.SP</Name>
    <LastEdit Timestamp="2026-02-25T08:50:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MILTON" b2="69 KV" b3="NUMBERCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="MILTON" b2="69 KV" b3="NUMBERSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103970</SeqNum>
    <Name>ClarkSummit.Cardinal.SP</Name>
    <LastEdit Timestamp="2026-03-02T11:38:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CLARKSUM" b2="34.5 KV" b3="CARDNLCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CLARKSUM" b2="34.5 KV" b3="CARDNLSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103971</SeqNum>
    <Name>Philipsburg.SchoolHouse1.SP</Name>
    <LastEdit Timestamp="2026-03-02T11:15:59" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PHILIPSB" b2="115 KV" b3="UNSH_CB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PHILIPSB" b2="115 KV" b3="UNSH_SP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103972</SeqNum>
    <Name>Midland.Pine1.SP</Name>
    <LastEdit Timestamp="2026-03-02T11:19:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MIDLAND" b2="23 KV" b3="BPINE1SP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLAND" b2="23 KV" b3="SPINE1CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103973</SeqNum>
    <Name>Midland.Pine2.SP</Name>
    <LastEdit Timestamp="2026-03-02T11:19:50" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="MIDLAND" b2="23 KV" b3="BPINE2SP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIDLAND" b2="23 KV" b3="SPINE2CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103974</SeqNum>
    <Name>IronBridge.SpringLane.SP</Name>
    <LastEdit Timestamp="2026-03-02T11:56:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IRONBRID" b2="25 KV" b3="SPRNGLCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="IRONBRID" b2="25 KV" b3="SPRNGLSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103980</SeqNum>
    <Name>L230.Lockridge-PrenticeDrive.2295</Name>
    <LastEdit Timestamp="2026-03-04T10:26:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKRDGE" b2="230 KV" b3="229572" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCKRDGE" b2="230 KV" b3="H12T2295" />
      <ContingencyEquipment Action="L" Type="LN" b1="LOCKRDGE" b2="230 KV" b3="LOC-PREN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRENTICE" b2="230 KV" b3="229532" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRENTICE" b2="230 KV" b3="YT2295" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103981</SeqNum>
    <Name>L138.AllenIM-Zodiac.4</Name>
    <LastEdit Timestamp="2026-03-04T10:38:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENIM" b2="138 KV" b3="ALL-ZOD4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="J" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="J1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008P5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008P8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103982</SeqNum>
    <Name>L138.AllenIM-Zodiac.3</Name>
    <LastEdit Timestamp="2026-03-04T10:43:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="ALLENIM" b2="138 KV" b3="ALL-ZOD3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLENIM" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008Q5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008Q8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103991</SeqNum>
    <Name>L345.Quot-Xena.4617</Name>
    <LastEdit Timestamp="2026-03-09T12:19:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="QUOT" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="QUOT" b2="345 KV" b3="V7" />
      <ContingencyEquipment Action="L" Type="LN" b1="QUOT" b2="345 KV" b3="QUO-XENA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="XENA" b2="345 KV" b3="V6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103992</SeqNum>
    <Name>L69.Juniata-Nwprt-Thmpsn-Wlkr-McAlvl-Rfld-Mfflntn</Name>
    <LastEdit Timestamp="2026-05-15T10:30:57" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="JUNIATA" b2="69 KV" b3="JUN-NEWP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="69 KV" b3="RFLD_N" />
      <ContingencyEquipment Action="OP" Type="CB" b1="JUNIATA" b2="69 KV" b3="RFLD_S" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MCALSTVL" b2="69 KV" b3="MCAL_LD" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MIFFLNTN" b2="69 KV" b3="MIFF_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCALSTVL" b2="69 KV" b3="MCA-RICH" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="RICHFLD" b2="69 KV" b3="RFLD_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MCALSTVL" b2="69 KV" b3="MCA-THOM" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEWPRTPL" b2="69 KV" b3="NEW-THOM" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THOMPNTN" b2="69 KV" b3="THOM_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="THOMPNTN" b2="69 KV" b3="TOM-WALK" />
      <ContingencyEquipment Action="L" Type="LN" b1="WALKERPL" b2="69 KV" b3="WAL-WAS2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="WALKERPL" b2="69 KV" b3="WALK_CAP" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="WALKERPL" b2="69 KV" b3="WALK_LD" />
      <ContingencyEquipment Action="L" Type="LN" b1="MIFFLNTN" b2="69 KV" b3="MIF-WAS1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALKERSO" b2="69 KV" b3="WALKERCB" />
      <ContingencyEquipment Action="L" Type="LN" b1="WALKERSO" b2="69 KV" b3="WAS-WAS1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103995</SeqNum>
    <Name>DTX230.SouthHall.LDW</Name>
    <LastEdit Timestamp="2026-03-16T12:46:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SOUTHALL" b2="230 KV" b3="230462-1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOUTHALL" b2="230 KV" b3="25562-1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOUTHALL" b2="230 KV" b3="LDW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103996</SeqNum>
    <Name>DTX230.SouthHall.LDY</Name>
    <LastEdit Timestamp="2026-03-16T12:46:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SOUTHALL" b2="230 KV" b3="230462-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOUTHALL" b2="230 KV" b3="25562-2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SOUTHALL" b2="230 KV" b3="LDY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103997</SeqNum>
    <Name>L161.Massac-JoppaN.7276 (AMIL/GLH)</Name>
    <LastEdit Timestamp="2026-03-17T10:37:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOPPA_N" b2="161 KV" b3="1605" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASSAC" b2="161 KV" b3="H35" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASSAC" b2="161 KV" b3="H43" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOPPA_N" b2="161 KV" b3="JOP-MAS2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103998</SeqNum>
    <Name>L161.Massac-JoppaN.7174 (AMIL/GLH)</Name>
    <LastEdit Timestamp="2026-03-17T10:43:07" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="JOPPA_N" b2="161 KV" b3="1616" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASSAC" b2="161 KV" b3="H33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MASSAC" b2="161 KV" b3="H35" />
      <ContingencyEquipment Action="L" Type="LN" b1="JOPPA_N" b2="161 KV" b3="JOP-MASS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>103999</SeqNum>
    <Name>L230.Cookstown-Larrabee</Name>
    <LastEdit Timestamp="2026-05-07T08:31:02" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="COOKSTOW" b2="230 KV" b3="B154" />
      <ContingencyEquipment Action="OP" Type="CB" b1="COOKSTOW" b2="230 KV" b3="B69" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRABEE" b2="230 KV" b3="B90" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LARRABEE" b2="230 KV" b3="B93" />
      <ContingencyEquipment Action="L" Type="LN" b1="COOKSTOW" b2="230 KV" b3="COO-LARR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104001</SeqNum>
    <Name>500/230.Fentress.TX4</Name>
    <LastEdit Timestamp="2026-03-19T14:28:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="500 KV" b3="H422-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="500 KV" b3="H422-5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="L422-10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="L422-11" />
      <ContingencyEquipment Action="X" Type="XF" b1="FENTRES4" b2="500 KV" b3="TX4_" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104002</SeqNum>
    <Name>L230.Fentress-Harpers.2253</Name>
    <LastEdit Timestamp="2026-03-20T10:11:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="22532210" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="22532211" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARPERS" b2="230 KV" b3="225302" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARPERS" b2="230 KV" b3="22532270" />
      <ContingencyEquipment Action="L" Type="LN" b1="FENTRES4" b2="230 KV" b3="FEN-HAR3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104003</SeqNum>
    <Name>L230.Fentress-Harpers.2252B</Name>
    <LastEdit Timestamp="2026-03-19T15:08:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FENTRES4" b2="230 KV" b3="225222" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARPERS" b2="230 KV" b3="226702" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARPERS" b2="230 KV" b3="226702-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARPERS" b2="230 KV" b3="22672272" />
      <ContingencyEquipment Action="L" Type="LN" b1="FENTRES4" b2="230 KV" b3="FEN-HAR5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HARPERS" b2="230 KV" b3="SVM5" />
      <ContingencyEquipment Action="U" Type="GEN" b1="HARPERS" b2="230 KV" b3="SVM6" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104005</SeqNum>
    <Name>L138.NauvooRidge-GeorgeWashington</Name>
    <LastEdit Timestamp="2026-03-26T12:55:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="GEORGEWA" b2="138 KV" b3="GEO-NAUV" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="138 KV" b3="R" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GEORGEWA" b2="138 KV" b3="R1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAUVOORI" b2="138 KV" b3="H001S2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAUVOORI" b2="138 KV" b3="H001S5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104006</SeqNum>
    <Name>DTX138.NauvooRidge.XCL2</Name>
    <LastEdit Timestamp="2026-03-26T12:59:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NAUVOORI" b2="138 KV" b3="H001T5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAUVOORI" b2="138 KV" b3="H001T8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NAUVOORI" b2="138 KV" b3="XCL2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104007</SeqNum>
    <Name>DTX138.NauvooRidge.XCL1</Name>
    <LastEdit Timestamp="2026-03-26T13:00:35" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NAUVOORI" b2="138 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAUVOORI" b2="138 KV" b3="A2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="NAUVOORI" b2="138 KV" b3="XCL1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104014</SeqNum>
    <Name>Robley.MaonSP</Name>
    <LastEdit Timestamp="2026-03-31T10:18:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="ROBLEY" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROBLEY" b2="115 KV" b3="MAONCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="ROBLEY" b2="34.5 KV" b3="MAONSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104015</SeqNum>
    <Name>345/138.Babbitt.TR2</Name>
    <LastEdit Timestamp="2026-03-31T10:30:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="345 KV" b3="AE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="345 KV" b3="H019G8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="H022Y5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BABBITT" b2="138 KV" b3="H022Y8" />
      <ContingencyEquipment Action="X" Type="XF" b1="BABBITT" b2="345 KV" b3="TR2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104016</SeqNum>
    <Name>DTX138.Zodiac.AQUAF&amp;PISCESD</Name>
    <LastEdit Timestamp="2026-05-08T14:43:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ZODIAC" b2="138 KV" b3="AQUAF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008P2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008P5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ZODIAC" b2="138 KV" b3="PISCESD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104018</SeqNum>
    <Name>345/138.IPVA.TR1 (AMIL)</Name>
    <LastEdit Timestamp="2026-04-02T16:49:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="IPVA" b2="138 KV" b3="52 1" />
      <ContingencyEquipment Action="X" Type="XF" b1="IPVA" b2="345 KV" b3="TR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IPVA" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="IPVA" b2="345 KV" b3="V15" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104019</SeqNum>
    <Name>L345.Montgomery-Scar.5679 (AMMO)</Name>
    <LastEdit Timestamp="2026-04-02T18:54:18" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="MONTGMR3" b2="345 KV" b3="MON-SCAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTGMR3" b2="345 KV" b3="V31" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MONTGMR3" b2="345 KV" b3="V33" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCAR" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCAR" b2="345 KV" b3="V3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104020</SeqNum>
    <Name>L345.Labadie-Scar.5608 (AMMO)</Name>
    <LastEdit Timestamp="2026-04-02T18:55:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="LABADIE3" b2="345 KV" b3="L MTGY 4" />
      <ContingencyEquipment Action="L" Type="LN" b1="LABADIE3" b2="345 KV" b3="LAB-SCAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCAR" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SCAR" b2="345 KV" b3="V9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104023</SeqNum>
    <Name>L345.GunnRoad.SCIOTORIDGE.SP</Name>
    <LastEdit Timestamp="2026-04-08T09:59:55" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GUNNROAD" b2="345 KV" b3="H025P2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GUNNROAD" b2="345 KV" b3="M2" />
      <ContingencyEquipment Action="X" Type="XF" b1="GUNNROAD" b2="345 KV" b3="MPT-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUNNROAD" b2="34.5 KV" b3="SCIOT2BS" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUNNROAD" b2="34.5 KV" b3="SCIOT2SP" />
      <ContingencyEquipment Action="U" Type="GEN" b1="GUNNROAD" b2="34.5 KV" b3="SCIOTOSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104024</SeqNum>
    <Name>DTX138.Marion.T3</Name>
    <LastEdit Timestamp="2026-04-09T15:08:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="6" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="H015D2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MARION2" b2="138 KV" b3="H024T2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARION2" b2="138 KV" b3="T3" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="MARION2" b2="138 KV" b3="T4" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104025</SeqNum>
    <Name>Chestertown.SP</Name>
    <LastEdit Timestamp="2026-04-13T15:49:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="CHESTERT" b2="69 KV" b3="52-T1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="CHESTERT" b2="34.5 KV" b3="CHESTRSP" />
      <ContingencyEquipment Action="X" Type="XF" b1="CHESTERT" b2="69 KV" b3="MPT-1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104026</SeqNum>
    <Name>L500.Souci-Driver (EAI/MISO)</Name>
    <LastEdit Timestamp="2026-05-11T15:35:11" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="DRIVER" b2="500 KV" b3="B8438" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRIVER" b2="500 KV" b3="B8865" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DRIVER" b2="500 KV" b3="B8875" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANSSU" b2="500 KV" b3="B3935" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SANSSU" b2="500 KV" b3="B3975" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="SANSSU" b2="500 KV" b3="B3980" />
      <ContingencyEquipment Action="L" Type="LN" b1="DRIVER" b2="500 KV" b3="DRI-SANS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104027</SeqNum>
    <Name>L138.Tiffany-Thompson-Warriner</Name>
    <LastEdit Timestamp="2026-04-10T18:05:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="THOMPSON" b2="115 KV" b3="1 TX" />
      <ContingencyEquipment Action="L" Type="LN" b1="THOMPSON" b2="115 KV" b3="THO-WARR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TIFFANY" b2="115 KV" b3="B19" />
      <ContingencyEquipment Action="L" Type="LN" b1="THOMPSON" b2="115 KV" b3="THO-TIF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINER" b2="115 KV" b3="B53" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WARRINER" b2="115 KV" b3="B59" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104029</SeqNum>
    <Name>DTX138.Zodiac.AQUAE&amp;PISCESC</Name>
    <LastEdit Timestamp="2026-05-08T14:43:43" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ZODIAC" b2="138 KV" b3="AQUAE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008Q2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M008Q5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M009V2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ZODIAC" b2="138 KV" b3="M009V5" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ZODIAC" b2="138 KV" b3="PISCESC" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104030</SeqNum>
    <Name>138/12.36Madison.TR71 S</Name>
    <LastEdit Timestamp="2026-04-14T10:37:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="36 MADIS" b2="138 KV" b3="TR71 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="36 MADIS" b2="138 KV" b3="TR71 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104031</SeqNum>
    <Name>138/12.36Madison.TR74 S</Name>
    <LastEdit Timestamp="2026-04-14T10:38:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="36 MADIS" b2="138 KV" b3="TR74 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="36 MADIS" b2="138 KV" b3="TR74 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104032</SeqNum>
    <Name>138/12.36Madison.TR72 S</Name>
    <LastEdit Timestamp="2026-04-14T10:38:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="36 MADIS" b2="138 KV" b3="TR72 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="36 MADIS" b2="138 KV" b3="TR72 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104033</SeqNum>
    <Name>138/12.36Madison.TR73 S</Name>
    <LastEdit Timestamp="2026-04-14T10:39:13" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="36 MADIS" b2="138 KV" b3="TR73 12" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="36 MADIS" b2="138 KV" b3="TR73 M" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104034</SeqNum>
    <Name>DTX345.Bermuda.ARNOR1</Name>
    <LastEdit Timestamp="2026-04-14T15:16:41" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERMUDA" b2="345 KV" b3="ARNOR1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERMUDA" b2="345 KV" b3="H021G5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERMUDA" b2="345 KV" b3="H021G8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104035</SeqNum>
    <Name>DTX345.Bermuda.ARNOR2</Name>
    <LastEdit Timestamp="2026-04-14T15:17:14" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERMUDA" b2="345 KV" b3="ARNOR2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERMUDA" b2="345 KV" b3="H021F5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERMUDA" b2="345 KV" b3="H021F8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104036</SeqNum>
    <Name>DTX345.Bermuda.ARNOR3</Name>
    <LastEdit Timestamp="2026-04-14T15:17:46" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERMUDA" b2="345 KV" b3="ARNOR3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERMUDA" b2="345 KV" b3="H021D5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERMUDA" b2="345 KV" b3="H021D8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104037</SeqNum>
    <Name>DTX345.Bermuda.ARNOR4</Name>
    <LastEdit Timestamp="2026-04-14T15:18:17" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="BERMUDA" b2="345 KV" b3="ARNOR4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERMUDA" b2="345 KV" b3="H021C5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BERMUDA" b2="345 KV" b3="H021C8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104038</SeqNum>
    <Name>L138.Itasca-W469.10104</Name>
    <LastEdit Timestamp="2026-04-15T15:00:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="101 ITAS" b2="138 KV" b3="IT4-W469" />
      <ContingencyEquipment Action="OP" Type="CB" b1="101 ITAS" b2="138 KV" b3="L10104CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W-469" b2="138 KV" b3="BT6-7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="W-469" b2="138 KV" b3="BT7-8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104039</SeqNum>
    <Name>DTX138.FifthAve.T1</Name>
    <LastEdit Timestamp="2026-04-16T14:05:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="FIFTHAVE" b2="138 KV" b3="H010Z2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FIFTHAVE" b2="138 KV" b3="H011A2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="FIFTHAVE" b2="138 KV" b3="T1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104040</SeqNum>
    <Name>765/345.Reynolds.T3</Name>
    <LastEdit Timestamp="2026-05-08T11:47:48" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="30-XF3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="765 KV" b3="BUSTIE" />
      <ContingencyEquipment Action="X" Type="XF" b1="REYNOLD2" b2="765 KV" b3="T3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="765 KV" b3="XF3BKR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="REYNOLD2" b2="345 KV" b3="XF3CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104041</SeqNum>
    <Name>DTX138.GreenChapel.T8</Name>
    <LastEdit Timestamp="2026-04-16T15:12:01" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008Q5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008Q8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENCHA" b2="138 KV" b3="T8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104042</SeqNum>
    <Name>DTX138.GreenChapel.T9</Name>
    <LastEdit Timestamp="2026-04-16T15:12:39" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008R5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENCHA" b2="138 KV" b3="H008R8" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="GREENCHA" b2="138 KV" b3="T9" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104043</SeqNum>
    <Name>L345.DuneAcres-GaryAve (NIPS)</Name>
    <LastEdit Timestamp="2026-04-22T09:38:51" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNEACRE" b2="345 KV" b3="10" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DUNEACRE" b2="345 KV" b3="210" />
      <ContingencyEquipment Action="L" Type="LN" b1="DUNEACRE" b2="345 KV" b3="DUN-GAR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GARYAVE" b2="345 KV" b3="34510_BR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104047</SeqNum>
    <Name>L230.AWS-Susquehanna230kV.YARDSPAN2</Name>
    <LastEdit Timestamp="2026-04-20T12:51:06" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="AWS" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="AWSHAR1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUSQUEHA" b2="69 KV" b3="LD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="SUSQUEHA" b2="69 KV" b3="LD2" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUSQUEHA" b2="230 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SUSQUEHA" b2="230 KV" b3="T1-T2_CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="SUSQUEHA" b2="230 KV" b3="T2" />
      <ContingencyEquipment Action="S" Type="SD" b1="SUSQUEHA" b2="230 KV" b3="YARDSPN2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104049</SeqNum>
    <Name>L500.Bradley-Conasaug </Name>
    <LastEdit Timestamp="2026-04-22T10:14:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADLEY4" b2="500 KV" b3="5024" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BRADLEY4" b2="500 KV" b3="5028" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASAUG" b2="500 KV" b3="110" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CONASAUG" b2="500 KV" b3="220" />
      <ContingencyEquipment Action="L" Type="LN" b1="BRADLEY4" b2="500 KV" b3="BRA-CONA" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104050</SeqNum>
    <Name>L500.Norcross-Southhall</Name>
    <LastEdit Timestamp="2026-04-22T09:38:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NORCROS" b2="500 KV" b3="930" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NORCROS" b2="500 KV" b3="950" />
      <ContingencyEquipment Action="L" Type="LN" b1="NORCROS" b2="500 KV" b3="NOR-SOUT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOUTHHAL" b2="500 KV" b3="510" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SOUTHHAL" b2="500 KV" b3="530" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104052</SeqNum>
    <Name>Swainton.69.Cap1</Name>
    <LastEdit Timestamp="2026-04-22T16:36:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="SWAINTON" b2="69 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SWAINTON" b2="69 KV" b3="J" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104053</SeqNum>
    <Name>L138.Lick-Pattonsville-Rhodes-CityJack</Name>
    <LastEdit Timestamp="2026-04-23T15:32:21" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="CITYJACK" b2="138 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICK" b2="138 KV" b3="103" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LICK" b2="138 KV" b3="104" />
      <ContingencyEquipment Action="L" Type="LN" b1="CITYJACK" b2="138 KV" b3="CIT-PATT" />
      <ContingencyEquipment Action="L" Type="LN" b1="LICK" b2="138 KV" b3="LIC-PATT" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RHODS" b2="138 KV" b3="C2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="RHODS" b2="138 KV" b3="D1" />
      <ContingencyEquipment Action="L" Type="LN" b1="PATTONSV" b2="138 KV" b3="PAT-RHOD" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104054</SeqNum>
    <Name>L345.Herleman-Meredosia</Name>
    <LastEdit Timestamp="2026-04-26T14:55:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="HERLEMAN" b2="345 KV" b3="HER-MERI" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERLEMAN" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HERLEMAN" b2="345 KV" b3="V13" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEREDOS3" b2="345 KV" b3="V11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MEREDOS3" b2="345 KV" b3="V13" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104055</SeqNum>
    <Name>L230.Oakboro-Ansonville-WDBS-Lilesville (CPL)</Name>
    <LastEdit Timestamp="2026-04-28T13:12:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="LD" Type="LOAD" b1="ANSONVL" b2="230 KV" b3="248_TOPO" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANSONVL" b2="230 KV" b3="ANS-WAD" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LILESVIL" b2="230 KV" b3="OAKB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LILESVIL" b2="230 KV" b3="ROCKOAKB" />
      <ContingencyEquipment Action="L" Type="LN" b1="ANSONVL" b2="230 KV" b3="31086A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OAKBORO" b2="230 KV" b3="LILESB" />
      <ContingencyEquipment Action="L" Type="LN" b1="LILESVIL" b2="230 KV" b3="LIL-WDBS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104056</SeqNum>
    <Name>L500.Plateau-Roane (TVA)</Name>
    <LastEdit Timestamp="2026-04-28T13:50:54" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="PLATEAU" b2="500 KV" b3="5034" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PLATEAU" b2="500 KV" b3="6036" />
      <ContingencyEquipment Action="L" Type="LN" b1="PLATEAU" b2="500 KV" b3="PLA-ROA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANE" b2="500 KV" b3="5044" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ROANE" b2="500 KV" b3="5048" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104057</SeqNum>
    <Name>L500.Dell-NewMadrid (TVA)</Name>
    <LastEdit Timestamp="2026-04-28T15:04:09" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DELL" b2="500 KV" b3="B8364" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DELL" b2="500 KV" b3="B8368" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="WNEWMAD" b2="500 KV" b3="5015" />
      <ContingencyEquipment Action="L" Type="LN" b1="DELL" b2="500 KV" b3="DEL-WNEW" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104058</SeqNum>
    <Name>L230.Green-Steele.23007</Name>
    <LastEdit Timestamp="2026-04-29T17:17:10" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENDPL" b2="230 KV" b3="230" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GREENDPL" b2="230 KV" b3="231" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="230 KV" b3="256" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STEELE" b2="230 KV" b3="9240" />
      <ContingencyEquipment Action="L" Type="LN" b1="GREENDPL" b2="230 KV" b3="GRE-STEE" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104060</SeqNum>
    <Name>Harpers.SV1</Name>
    <LastEdit Timestamp="2026-04-29T17:48:27" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="U" Type="GEN" b1="HARPERS" b2="230 KV" b3="SV1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="HARPERS" b2="230 KV" b3="SV102" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104061</SeqNum>
    <Name>345/138.135Elmhurst.TR84</Name>
    <LastEdit Timestamp="2026-05-01T12:49:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="345 KV" b3="3-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="135 ELMH" b2="138 KV" b3="TR84 CB" />
      <ContingencyEquipment Action="X" Type="XF" b1="135 ELMH" b2="345 KV" b3="TR84CT-P" />
      <ContingencyEquipment Action="X" Type="XF" b1="135 ELMH" b2="138 KV" b3="TR84CT-S" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104062</SeqNum>
    <Name>230/34.Lock.T1 </Name>
    <LastEdit Timestamp="2026-05-07T08:37:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LOCK" b2="230 KV" b3="1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCK" b2="34 KV" b3="15" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCK" b2="230 KV" b3="715" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104063</SeqNum>
    <Name>230/34.Lock.T2 </Name>
    <LastEdit Timestamp="2026-05-07T08:39:42" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="LOCK" b2="230 KV" b3="2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCK" b2="34 KV" b3="25" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LOCK" b2="230 KV" b3="915" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104065</SeqNum>
    <Name>L138.Terminal-Elmwood</Name>
    <LastEdit Timestamp="2026-05-11T10:30:08" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="08EMWOD1" b2="138 KV" b3="812" />
      <ContingencyEquipment Action="OP" Type="CB" b1="08EMWOD1" b2="138 KV" b3="815" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="08EMWOD1" b2="138 KV" b3="TB8" />
      <ContingencyEquipment Action="L" Type="LN" b1="08EMWOD1" b2="138 KV" b3="08E-TER1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TERMINAL" b2="138 KV" b3="910" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104066</SeqNum>
    <Name>L345.Keystone-Whippleditch</Name>
    <LastEdit Timestamp="2026-05-05T14:19:33" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTNE" b2="345 KV" b3="A" />
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTNE" b2="345 KV" b3="B" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEYSTNE" b2="345 KV" b3="KEY-WHPL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHPLDICH" b2="345 KV" b3="C" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WHPLDICH" b2="345 KV" b3="D" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104067</SeqNum>
    <Name>500/230.GooseCreek.TX1 (Sctnlz)</Name>
    <LastEdit Timestamp="2026-05-08T15:14:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="GOOSECRE" b2="500 KV" b3="H184M" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRE" b2="230 KV" b3="L1T227" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GOOSECRE" b2="230 KV" b3="L1T2286" />
      <ContingencyEquipment Action="X" Type="XF" b1="GOOSECRE" b2="500 KV" b3="TX1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104069</SeqNum>
    <Name>L500.Choctaw-Clay (TVA)</Name>
    <LastEdit Timestamp="2026-05-06T10:33:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="8CHOCTAW" b2="500 KV" b3="5014" />
      <ContingencyEquipment Action="OP" Type="CB" b1="8CHOCTAW" b2="500 KV" b3="5018" />
      <ContingencyEquipment Action="L" Type="LN" b1="8CHOCTAW" b2="500 KV" b3="CHO-CLAY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="8CLAY MS" b2="500 KV" b3="5028" />
      <ContingencyEquipment Action="OP" Type="CB" b1="8CLAY MS" b2="500 KV" b3="5034" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104070</SeqNum>
    <Name>L345.Bisn-Mogl (AMIL)</Name>
    <LastEdit Timestamp="2026-05-06T11:53:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="BISN" b2="345 KV" b3="BIS-MOGL" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISN" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BISN" b2="345 KV" b3="V3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOGL" b2="345 KV" b3="V1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MOGL" b2="345 KV" b3="V5" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104073</SeqNum>
    <Name>L345.Oneida-Oxby (MISO)</Name>
    <LastEdit Timestamp="2026-05-13T14:26:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ONEIDA" b2="345 KV" b3="30F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ONEIDA" b2="345 KV" b3="30R8" />
      <ContingencyEquipment Action="L" Type="LN" b1="ONEIDA" b2="345 KV" b3="ONE-OXBY" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OXBY" b2="345 KV" b3="31H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OXBY" b2="345 KV" b3="31R8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104074</SeqNum>
    <Name>L345.BattleCreek-Oxby (MISO)</Name>
    <LastEdit Timestamp="2026-05-06T15:13:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="BATTLECR" b2="345 KV" b3="32F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="BATTLECR" b2="345 KV" b3="34H9" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OXBY" b2="345 KV" b3="31F7" />
      <ContingencyEquipment Action="OP" Type="CB" b1="OXBY" b2="345 KV" b3="31H9" />
      <ContingencyEquipment Action="L" Type="LN" b1="BATTLECR" b2="345 KV" b3="BAT-OXBY" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104075</SeqNum>
    <Name>TEMP:L230.CranesCorner-Stafford-AquiaHarbor.2104T</Name>
    <LastEdit Timestamp="2026-05-29T12:53:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUAHAR" b2="230 KV" b3="21042119" />
      <ContingencyEquipment Action="OP" Type="CB" b1="AQUAHAR" b2="230 KV" b3="252T2104" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRANESCR" b2="230 KV" b3="21042157" />
      <ContingencyEquipment Action="L" Type="LN" b1="AQUAHAR" b2="230 KV" b3="AQU-CRAN" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="CRANESCR" b2="230 KV" b3="DUMD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="STAFFORD" b2="230 KV" b3="2104B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAFFORD" b2="230 KV" b3="H152" />
      <ContingencyEquipment Action="OP" Type="CB" b1="STAFFORD" b2="230 KV" b3="H252" />
      <ContingencyEquipment Action="X" Type="XF" b1="STAFFORD" b2="230 KV" b3="TX1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STAFFORD" b2="35 KV" b3="TX1" />
      <ContingencyEquipment Action="X" Type="XF" b1="STAFFORD" b2="230 KV" b3="TX2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="STAFFORD" b2="35 KV" b3="TX2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104083</SeqNum>
    <Name>TEMP.TannersCreek-MiamiFort+TannersCreek-EastBend</Name>
    <LastEdit Timestamp="2026-05-11T14:49:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1401" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MIAMIFOR" b2="345 KV" b3="1403" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="T" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="T1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TANNERSC" b2="345 KV" b3="T2" />
      <ContingencyEquipment Action="L" Type="LN" b1="TANNERSC" b2="345 KV" b3="TAN-EBE1" />
      <ContingencyEquipment Action="L" Type="LN" b1="TANNERSC" b2="345 KV" b3="TAN-MIA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104086</SeqNum>
    <Name>L345.Gibson-PetersB (CIN/IPL)</Name>
    <LastEdit Timestamp="2026-05-11T15:40:53" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON2" b2="345 KV" b3="07G1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GIBSON2" b2="345 KV" b3="4507" />
      <ContingencyEquipment Action="L" Type="LN" b1="GIBSON2" b2="345 KV" b3="GIB-PET1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="2B" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PETERSB2" b2="345 KV" b3="2C" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104087</SeqNum>
    <Name>L345.Majestic-Tompkins (ITC/CONS)</Name>
    <LastEdit Timestamp="2026-05-11T15:50:28" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="MAJESTIC" b2="345 KV" b3="BF" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MAJESTIC" b2="345 KV" b3="BM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOMPKINS" b2="345 KV" b3="26R8" />
      <ContingencyEquipment Action="OP" Type="CB" b1="TOMPKINS" b2="345 KV" b3="28H9" />
      <ContingencyEquipment Action="L" Type="LN" b1="MAJESTIC" b2="345 KV" b3="MAJ-TOM" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104088</SeqNum>
    <Name>L115.Allen-WilliamsGrove</Name>
    <LastEdit Timestamp="2026-05-28T17:14:04" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLEN" b2="115 KV" b3="B30" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ALLEN" b2="115 KV" b3="B35" />
      <ContingencyEquipment Action="L" Type="LN" b1="ALLEN" b2="115 KV" b3="WIL-ALLN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WILLGROV" b2="115 KV" b3="T3_LO" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104101</SeqNum>
    <Name>L69.Siegfried-KeystoneCement-Nazareth.1(sw/bypass)</Name>
    <LastEdit Timestamp="2026-05-15T15:39:30" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>N</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEYSTCEM" b2="69 KV" b3="1562" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEYSTCEM" b2="69 KV" b3="1563" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEYSTCEM" b2="69 KV" b3="KEY-SIE1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEYSTCEM" b2="69 KV" b3="SUB1_LD1" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEYSTCEM" b2="69 KV" b3="SUB2_LD1" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEYSTCEM" b2="69 KV" b3="KEY-NAZ1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="MAC2SIE1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="SIEG1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="NAZ1FRC1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="NAZA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104102</SeqNum>
    <Name>L345.Dee Mac Rd - 918 Dana.91509</Name>
    <LastEdit Timestamp="2026-05-19T13:28:03" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="915_DEEM" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="915_DEEM" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="918_DANA" b2="345 KV" b3="DAN-DEEM" />
      <ContingencyEquipment Action="OP" Type="CB" b1="918_DANA" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="918_DANA" b2="345 KV" b3="1-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104103</SeqNum>
    <Name>L345.Nevada - Dana.91815</Name>
    <LastEdit Timestamp="2026-05-28T17:05:29" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="918_DANA" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="918_DANA" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="L" Type="LN" b1="918_DANA" b2="345 KV" b3="DAN-NEVA" />
      <ContingencyEquipment Action="OP" Type="CB" b1="98 NEVAD" b2="345 KV" b3="BT 1-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="98 NEVAD" b2="345 KV" b3="BT 2-4" />
      <ContingencyEquipment Action="OP" Type="CB" b1="98 NEVAD" b2="345 KV" b3="IND_CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="98 NEVAD" b2="345 KV" b3="REA1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104104</SeqNum>
    <Name>915DeeMacRd.Panther.WF</Name>
    <LastEdit Timestamp="2026-06-03T14:52:15" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="915_DEEM" b2="345 KV" b3="1-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="915_DEEM" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="915_DEEM" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="915_DEEM" b2="34.5 KV" b3="CAP2" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="915_DEEM" b2="34.5 KV" b3="CAP3" />
      <ContingencyEquipment Action="U" Type="GEN" b1="915_DEEM" b2="34.5 KV" b3="PANTH1WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="915_DEEM" b2="34.5 KV" b3="PANTH2WF" />
      <ContingencyEquipment Action="U" Type="GEN" b1="915_DEEM" b2="34.5 KV" b3="PANTH3WF" />
      <ContingencyEquipment Action="X" Type="XF" b1="915_DEEM" b2="345 KV" b3="XFMR-1" />
      <ContingencyEquipment Action="X" Type="XF" b1="915_DEEM" b2="345 KV" b3="XFMR-2" />
      <ContingencyEquipment Action="X" Type="XF" b1="915_DEEM" b2="345 KV" b3="XFMR-3" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104105</SeqNum>
    <Name>Dana.OsaGrove.WF</Name>
    <LastEdit Timestamp="2026-05-28T12:10:24" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="918_DANA" b2="345 KV" b3="1-2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="918_DANA" b2="345 KV" b3="2-3" />
      <ContingencyEquipment Action="OP" Type="CB" b1="918_DANA" b2="345 KV" b3="L81801" />
      <ContingencyEquipment Action="X" Type="XF" b1="918_DANA" b2="345 KV" b3="MPT-1" />
      <ContingencyEquipment Action="U" Type="GEN" b1="918_DANA" b2="34.5 KV" b3="OSAGFLWF" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104107</SeqNum>
    <Name>L138.Crescent-Findlay.T-Z24/45</Name>
    <LastEdit Timestamp="2026-05-20T16:23:22" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="CRES DUQ" b2="138 KV" b3="CRE-FIN" />
      <ContingencyEquipment Action="OP" Type="CB" b1="CRES DUQ" b2="138 KV" b3="Z-24 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="FINDLAY" b2="138 KV" b3="MONTOUR" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104111</SeqNum>
    <Name>L69.Siegfried-KeystoneCement.2 (Protection)</Name>
    <LastEdit Timestamp="2026-05-26T10:46:56" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTCEM" b2="69 KV" b3="1454" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEYSTCEM" b2="69 KV" b3="1454_BYP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEYSTCEM" b2="69 KV" b3="1562" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEYSTCEM" b2="69 KV" b3="1563" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEYSTCEM" b2="69 KV" b3="KEY-SIE2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEYSTCEM" b2="69 KV" b3="SUB1_LD2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEYSTCEM" b2="69 KV" b3="SUB2_LD2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="NAZ2FRC2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SIEGFRIE" b2="69 KV" b3="NAZA2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104112</SeqNum>
    <Name>L69.Nazareth-KeystoneCement.2(Protection)</Name>
    <LastEdit Timestamp="2026-05-26T10:50:25" />
    <ActiveFlag>N</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="KEYSTCEM" b2="69 KV" b3="1454" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEYSTCEM" b2="69 KV" b3="1454_BYP" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEYSTCEM" b2="69 KV" b3="1562" />
      <ContingencyEquipment Action="OP" Type="DIS" b1="KEYSTCEM" b2="69 KV" b3="1563" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEYSTCEM" b2="69 KV" b3="SUB1_LD2" />
      <ContingencyEquipment Action="LD" Type="LOAD" b1="KEYSTCEM" b2="69 KV" b3="SUB2_LD2" />
      <ContingencyEquipment Action="L" Type="LN" b1="KEYSTCEM" b2="69 KV" b3="KEY-NAZ2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="QUA1SIE2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NAZARETH" b2="69 KV" b3="SIEG2" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104113</SeqNum>
    <Name>L230.Doubs-Sage</Name>
    <LastEdit Timestamp="2026-05-26T11:02:00" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ8 CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="DOUBS" b2="230 KV" b3="DJ9 CB" />
      <ContingencyEquipment Action="L" Type="LN" b1="DOUBS" b2="230 KV" b3="DOU-SAGE" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAGE" b2="230 KV" b3="B11" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SAGE" b2="230 KV" b3="DUMCB1" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104116</SeqNum>
    <Name>L138.EastElkhart-MengesDitch2</Name>
    <LastEdit Timestamp="2026-06-09T14:43:40" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EELKHART" b2="138 KV" b3="EEL-MEN2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="M000N2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="M000N5" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MENGDTCH" b2="138 KV" b3="127-X2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MENGDTCH" b2="138 KV" b3="127CB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104118</SeqNum>
    <Name>Galion.Blossom.SP</Name>
    <LastEdit Timestamp="2026-05-28T14:23:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="168" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="34.5 KV" b3="BLOSSOCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="34.5 KV" b3="C1" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GALION" b2="34.5 KV" b3="CAP1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="34.5 KV" b3="CAP1CB" />
      <ContingencyEquipment Action="CP" Type="CAP" b1="GALION" b2="34.5 KV" b3="CAP2" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="34.5 KV" b3="CAP2CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="DUMCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="GALION" b2="138 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="138 KV" b3="GSUHCB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="GALION" b2="34.5 KV" b3="GSULCB" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104119</SeqNum>
    <Name>L115.WalnutCreek-Sherwood.1068</Name>
    <LastEdit Timestamp="2026-06-04T12:07:56" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERWOOD" b2="115 KV" b3="106882" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALNTCRK" b2="115 KV" b3="39T1068" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALNTCRK" b2="115 KV" b3="91T1068" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHERWOOD" b2="115 KV" b3="SHE-WAL8" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104120</SeqNum>
    <Name>L115.WalnutCreek-Sherwood.1067</Name>
    <LastEdit Timestamp="2026-06-01T16:18:16" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="SHERWOOD" b2="115 KV" b3="106782" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALNTCRK" b2="115 KV" b3="39T1067" />
      <ContingencyEquipment Action="OP" Type="CB" b1="WALNTCRK" b2="115 KV" b3="91T1067" />
      <ContingencyEquipment Action="L" Type="LN" b1="SHERWOOD" b2="115 KV" b3="SHE-WAL7" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104121</SeqNum>
    <Name>L115.SouthJustice-NevilleFarm.1069</Name>
    <LastEdit Timestamp="2026-06-01T17:43:05" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="NEVLFARM" b2="115 KV" b3="10621069" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEVLFARM" b2="115 KV" b3="81T1069" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SJUSTICE" b2="115 KV" b3="10151069" />
      <ContingencyEquipment Action="OP" Type="CB" b1="SJUSTICE" b2="115 KV" b3="106992" />
      <ContingencyEquipment Action="L" Type="LN" b1="NEVLFARM" b2="115 KV" b3="NEV-SJUS" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104122</SeqNum>
    <Name>NevilleFarm.Halifax.SP</Name>
    <LastEdit Timestamp="2026-06-02T11:42:36" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="X" Type="XF" b1="NEVLFARM" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="NEVLFARM" b2="115 KV" b3="HALIFXCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="NEVLFARM" b2="34.5 KV" b3="HALIFXSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104139</SeqNum>
    <Name>115/34.PortRepublic-GSU+StoneWSP</Name>
    <LastEdit Timestamp="2026-06-05T08:43:23" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="CP" Type="CAP" b1="PRTRPBLC" b2="34.5 KV" b3="CAP" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRTRPBLC" b2="34.5 KV" b3="CAPCB" />
      <ContingencyEquipment Action="X" Type="XF" b1="PRTRPBLC" b2="115 KV" b3="GSU" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRTRPBLC" b2="115 KV" b3="STONEWCB" />
      <ContingencyEquipment Action="U" Type="GEN" b1="PRTRPBLC" b2="34.5 KV" b3="STONEWSP" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104140</SeqNum>
    <Name>L115.PortRepublic-Grottoes.1089</Name>
    <LastEdit Timestamp="2026-06-05T08:55:58" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="GROTTOES" b2="115 KV" b3="108982" />
      <ContingencyEquipment Action="L" Type="LN" b1="GROTTOES" b2="115 KV" b3="GRO-PRTR" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRTRPBLC" b2="115 KV" b3="108962" />
      <ContingencyEquipment Action="OP" Type="CB" b1="PRTRPBLC" b2="115 KV" b3="119T1089" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104142</SeqNum>
    <Name>L345.LimeLake-EastStolleRoad [NYISO]</Name>
    <LastEdit Timestamp="2026-06-04T14:13:25" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="OP" Type="CB" b1="ESTOLLER" b2="345 KV" b3="2B3003" />
      <ContingencyEquipment Action="OP" Type="CB" b1="ESTOLLER" b2="345 KV" b3="2B3005" />
      <ContingencyEquipment Action="OP" Type="CB" b1="LIMELAKE" b2="345 KV" b3="804" />
      <ContingencyEquipment Action="L" Type="LN" b1="ESTOLLER" b2="345 KV" b3="EST-LIME" />
    </Equipment>
  </Contingency>
  <Contingency>
    <SeqNum>104143</SeqNum>
    <Name>L138.EastElkhart-MengesDitch1</Name>
    <LastEdit Timestamp="2026-06-09T14:48:45" />
    <ActiveFlag>Y</ActiveFlag>
    <DefaultFlag>Y</DefaultFlag>
    <Equipment>
      <ContingencyEquipment Action="L" Type="LN" b1="EELKHART" b2="138 KV" b3="EEL-MEN1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="H" />
      <ContingencyEquipment Action="OP" Type="CB" b1="EELKHART" b2="138 KV" b3="H1" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MENGDTCH" b2="138 KV" b3="128-00CB" />
      <ContingencyEquipment Action="OP" Type="CB" b1="MENGDTCH" b2="138 KV" b3="128CB" />
    </Equipment>
  </Contingency>
</Contingencies>