101018
Non-Market Post Contingency Local Load Relief Warn
2016-07-05T19:37Z
2016-07-06T04:18Z
A Non-Market Post Contingency Local Load Relief Warn has been issued to maintain COUNTYLI 138 KV at 127 KV in the AEP for Transmission Contingency Control.
Additional Comments: Post Contingency Switching available
false
false
Warning
2016-07-05T19:33Z
2016-07-06T04:18Z
2016-07-05T19:33Z
2016-07-06T04:18Z
AEP
Control Area
101017
Hot Weather Alert
2016-07-05T15:00Z
A Hot Weather Alert has been issued from 08:00 on 07.07.2016 through 23:59 on 07.07.2016 . As indicated in M-13, members are expected to perform the following actions:
- Generation (Gen) dispatchers review & update their unit parameters in Markets Gateway through the Hot Weather Alert period paying particular attention to accurate Start-up & Notification, Min Run Time, Max Run Time, Eco Min/Max and Emergency Min/Max information.
- Gen dispatchers with dual fuel units confirm the equipment is functional & amount of alternate fuel available
- Outages to the alternate fuel capability will be submitted to PJM via Markets Gateway.
- Alternate fuel restrictions will also be communicated via Markets Gateway.
- Gen dispatchers review fuel supply/delivery schedules in anticipation of greater than normal operation of units.
- Transmission/Gen dispatchers review plans to determine if any maintenance/testing, scheduled/being performed, on any monitoring, control, transmission/generating equipment can be deferred/canceled.
Additional Comments: For Thursday, July 7, 2016. A Hot Weather Alert is NOT a trigger for a Performance Assesment Hour.
false
false
Alert
2016-07-07T12:00Z
2016-07-08T03:59Z
2016-07-05T15:00Z
MIDATL
Region
101016
Minimum Generation Alert
2016-07-05T01:03Z
2016-07-05T09:05Z
A Minimum Generation Alert has been issued for the Midnight of 07.05.2016 Expected generation level is within 645 MW of normal minimum energy limits.
false
false
Alert
2016-07-05T00:55Z
2016-07-05T09:00Z
2016-07-05T00:55Z
2016-07-05T09:00Z
PJM-RTO
RTO
101015
Minimum Generation Alert
2016-07-03T23:14Z
2016-07-04T12:29Z
A Minimum Generation Alert has been issued for the Midnight Period of 07.04.2016 Expected generation level is within 1162 MW of normal minimum energy limits.
false
false
Alert
2016-07-03T23:05Z
2016-07-04T12:29Z
2016-07-03T23:05Z
2016-07-04T12:29Z
PJM-RTO
RTO
101014
Minimum Generation Alert
2016-07-03T00:33Z
2016-07-03T12:57Z
A Minimum Generation Alert has been issued for the Midnight period of 07.03.2016 Expected generation level is within -1633 MW of normal minimum energy limits.
false
false
Alert
2016-07-03T00:30Z
2016-07-03T12:57Z
2016-07-03T00:30Z
2016-07-03T12:57Z
PJM-RTO
RTO
101013
Minimum Generation Advisory
2016-07-01T12:06Z
2016-07-04T12:29Z
A Minimum Generation Advisory is being issued for the valley periods 07.02.2016 through 07.04.2016 . This advisory is being issued to provide advanced warning that due to mild weather and light loads, PJM may be entering into Min Gen Alerts and possibly Min Gen Actions during these periods. No action is required from the members at this time. This is an informational notice only. As we approach these valley periods, PJM will implement Min Gen Alerts/Actions on an as needed basis.
false
false
Advisory
2016-07-01T12:05Z
2016-07-04T12:29Z
2016-07-01T12:05Z
2016-07-04T12:29Z
PJM-RTO
RTO