Schema ircdownload.xsd


schema location P:\eDartXML\ircdownload.xsd
attributeFormDefault
elementFormDefault qualified
 
Elements 
adjustedPrimary 
adjustedSpinning 
companySubmittedData 
currentTimestamp 
date 
eastNormalRegulatingReserve 
eastSpinningNonRegulatingReserve 
eastSpinningRegulatingReserve 
edart 
intervalDefinition 
intervalStart 
ircReport 
largestContingency 
load 
normalRegulatingReserve 
operatingReserve 
poolTotals 
primaryReserve 
quickStartHydro 
quickStartOther 
regulation 
requiredPrimary 
requiredSpinning 
reserveGt30 
secondaryReserve 
spinningNonRegulatingReserve 
spinningRegulatingReserve 
time 
totalSpinningReserve 
unaccountedforCapacity 


element adjustedPrimary
diagram ircdownload_p1.png
type xs:integer
properties
content simple
source <xs:element name="adjustedPrimary" type="xs:integer"/>

element adjustedSpinning
diagram ircdownload_p2.png
type xs:integer
properties
content simple
source <xs:element name="adjustedSpinning" type="xs:integer"/>

element companySubmittedData
diagram ircdownload_p3.png
properties
content complex
children operatingReserve synchronizedReserve quickStartHydro quickStartOther supplemental
used by
element ircReport
attributes
Name  Type  Use  Default  Fixed  Annotation
controlZone  derived by: xs:NMTOKEN  required      
source <xs:element name="companySubmittedData">
 
<xs:complexType>
   
<xs:sequence>
     
<xs:element ref="operatingReserve"/>
     
<xs:element name="synchronizedReserve"/>
     
<xs:element ref="quickStartHydro"/>
     
<xs:element ref="quickStartOther"/>
     
<xs:element name="supplemental" type="xs:integer"/>
   
</xs:sequence>
   
<xs:attribute name="controlZone" use="required">
     
<xs:simpleType>
       
<xs:restriction base="xs:NMTOKEN"/>
     
</xs:simpleType>
   
</xs:attribute>
 
</xs:complexType>
</xs:element>

attribute companySubmittedData/@controlZone
type restriction of xs:NMTOKEN
properties
use required
source <xs:attribute name="controlZone" use="required">
 
<xs:simpleType>
   
<xs:restriction base="xs:NMTOKEN"/>
 
</xs:simpleType>
</xs:attribute>

element companySubmittedData/synchronizedReserve
diagram ircdownload_p4.png
source <xs:element name="synchronizedReserve"/>

element companySubmittedData/supplemental
diagram ircdownload_p5.png
type xs:integer
properties
content simple
source <xs:element name="supplemental" type="xs:integer"/>

element currentTimestamp
diagram ircdownload_p6.png
type xs:string
properties
content simple
used by
element ircReport
source <xs:element name="currentTimestamp" type="xs:string"/>

element date
diagram ircdownload_p7.png
type xs:date
properties
content simple
used by
element intervalStart
source <xs:element name="date" type="xs:date"/>

element eastNormalRegulatingReserve
diagram ircdownload_p8.png
type xs:integer
properties
content simple
source <xs:element name="eastNormalRegulatingReserve" type="xs:integer"/>

element eastSpinningNonRegulatingReserve
diagram ircdownload_p9.png
type xs:integer
properties
content simple
source <xs:element name="eastSpinningNonRegulatingReserve" type="xs:integer"/>

element eastSpinningRegulatingReserve
diagram ircdownload_p10.png
type xs:integer
properties
content simple
source <xs:element name="eastSpinningRegulatingReserve" type="xs:integer"/>

element edart
diagram ircdownload_p11.png
properties
content complex
children ircReport
source <xs:element name="edart">
 
<xs:complexType>
   
<xs:sequence>
     
<xs:element ref="ircReport"/>
   
</xs:sequence>
 
</xs:complexType>
</xs:element>

element intervalDefinition
diagram ircdownload_p12.png
properties
content complex
children intervalStart
used by
element ircReport
source <xs:element name="intervalDefinition">
 
<xs:complexType>
   
<xs:sequence>
     
<xs:element ref="intervalStart"/>
   
</xs:sequence>
 
</xs:complexType>
</xs:element>

element intervalStart
diagram ircdownload_p13.png
properties
content complex
children date time
used by
element intervalDefinition
source <xs:element name="intervalStart">
 
<xs:complexType>
   
<xs:sequence>
     
<xs:element ref="date"/>
     
<xs:element ref="time"/>
   
</xs:sequence>
 
</xs:complexType>
</xs:element>

element ircReport
diagram ircdownload_p14.png
properties
content complex
children intervalDefinition currentTimestamp companySubmittedData poolTotals
used by
element edart
attributes
Name  Type  Use  Default  Fixed  Annotation
requestId  xs:short  required      
source <xs:element name="ircReport">
 
<xs:complexType>
   
<xs:sequence>
     
<xs:element ref="intervalDefinition"/>
     
<xs:element ref="currentTimestamp"/>
     
<xs:element ref="companySubmittedData" minOccurs="0" maxOccurs="unbounded"/>
     
<xs:element ref="poolTotals" maxOccurs="unbounded"/>
   
</xs:sequence>
   
<xs:attribute name="requestId" type="xs:short" use="required"/>
 
</xs:complexType>
</xs:element>

attribute ircReport/@requestId
type xs:short
properties
use required
source <xs:attribute name="requestId" type="xs:short" use="required"/>

element largestContingency
diagram ircdownload_p15.png
type xs:integer
properties
content simple
used by
element poolTotals
source <xs:element name="largestContingency" type="xs:integer"/>

element load
diagram ircdownload_p16.png
type xs:integer
properties
content simple
source <xs:element name="load" type="xs:integer"/>

element normalRegulatingReserve
diagram ircdownload_p17.png
type xs:integer
properties
content simple
source <xs:element name="normalRegulatingReserve" type="xs:integer"/>

element operatingReserve
diagram ircdownload_p18.png
type xs:integer
properties
content simple
used by
elements companySubmittedData poolTotals
source <xs:element name="operatingReserve" type="xs:integer"/>

element poolTotals
diagram ircdownload_p19.png
properties
content complex
children totalSynchronizedReserve operatingReserve requiredSynchronized adjustedSynchronized primaryReserve adjustedPrimaryReserve largestContingency
used by
element ircReport
attributes
Name  Type  Use  Default  Fixed  Annotation
reserveArea  derived by: xs:NMTOKEN  required      
source <xs:element name="poolTotals">
 
<xs:complexType>
   
<xs:sequence>
     
<xs:element name="totalSynchronizedReserve"/>
     
<xs:element ref="operatingReserve"/>
     
<xs:element name="requiredSynchronized" type="xs:integer"/>
     
<xs:element name="adjustedSynchronized" type="xs:integer"/>
     
<xs:element ref="primaryReserve"/>
     
<xs:element name="adjustedPrimaryReserve"/>
     
<xs:element ref="largestContingency" minOccurs="0"/>
   
</xs:sequence>
   
<xs:attribute name="reserveArea" use="required">
     
<xs:simpleType>
       
<xs:restriction base="xs:NMTOKEN"/>
     
</xs:simpleType>
   
</xs:attribute>
 
</xs:complexType>
</xs:element>

attribute poolTotals/@reserveArea
type restriction of xs:NMTOKEN
properties
use required
source <xs:attribute name="reserveArea" use="required">
 
<xs:simpleType>
   
<xs:restriction base="xs:NMTOKEN"/>
 
</xs:simpleType>
</xs:attribute>

element poolTotals/totalSynchronizedReserve
diagram ircdownload_p20.png
source <xs:element name="totalSynchronizedReserve"/>

element poolTotals/requiredSynchronized
diagram ircdownload_p21.png
type xs:integer
properties
content simple
source <xs:element name="requiredSynchronized" type="xs:integer"/>

element poolTotals/adjustedSynchronized
diagram ircdownload_p22.png
type xs:integer
properties
content simple
source <xs:element name="adjustedSynchronized" type="xs:integer"/>

element poolTotals/adjustedPrimaryReserve
diagram ircdownload_p23.png
source <xs:element name="adjustedPrimaryReserve"/>

element primaryReserve
diagram ircdownload_p24.png
type xs:integer
properties
content simple
used by
element poolTotals
source <xs:element name="primaryReserve" type="xs:integer"/>

element quickStartHydro
diagram ircdownload_p25.png
type xs:integer
properties
content simple
used by
element companySubmittedData
source <xs:element name="quickStartHydro" type="xs:integer"/>

element quickStartOther
diagram ircdownload_p26.png
type xs:integer
properties
content simple
used by
element companySubmittedData
source <xs:element name="quickStartOther" type="xs:integer"/>

element regulation
diagram ircdownload_p27.png
type xs:integer
properties
content simple
nillable 0
source <xs:element name="regulation" type="xs:integer" nillable="0"/>

element requiredPrimary
diagram ircdownload_p28.png
type xs:integer
properties
content simple
source <xs:element name="requiredPrimary" type="xs:integer"/>

element requiredSpinning
diagram ircdownload_p29.png
type xs:integer
properties
content simple
source <xs:element name="requiredSpinning" type="xs:integer"/>

element reserveGt30
diagram ircdownload_p30.png
type xs:integer
properties
content simple
source <xs:element name="reserveGt30" type="xs:integer"/>

element secondaryReserve
diagram ircdownload_p31.png
type xs:integer
properties
content simple
source <xs:element name="secondaryReserve" type="xs:integer"/>

element spinningNonRegulatingReserve
diagram ircdownload_p32.png
type xs:integer
properties
content simple
source <xs:element name="spinningNonRegulatingReserve" type="xs:integer"/>

element spinningRegulatingReserve
diagram ircdownload_p33.png
type xs:integer
properties
content simple
source <xs:element name="spinningRegulatingReserve" type="xs:integer"/>

element time
diagram ircdownload_p34.png
type xs:time
properties
content simple
used by
element intervalStart
source <xs:element name="time" type="xs:time"/>

element totalSpinningReserve
diagram ircdownload_p35.png
type xs:integer
properties
content simple
source <xs:element name="totalSpinningReserve" type="xs:integer"/>

element unaccountedforCapacity
diagram ircdownload_p36.png
type xs:integer
properties
content simple
source <xs:element name="unaccountedforCapacity" type="xs:integer"/>


XML Schema documentation generated by XMLSpy Schema Editor http://www.altova.com/xmlspy