Schema transticreview.xsd


schema location: 
attributeFormDefault: 
elementFormDefault:  qualified
 
Elements  Complex types 
conflict  equipment_default 
cutInTask  FileList 
date  modeling_requests 
edart  ModelingRequest 
interval_definition  restplan 
time  takeout_restore 


element conflict
diagram transticreview_p1.png
properties
content complex
children ticket scenario
used by
element edart/transticreview
source <xsd:element name="conflict">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="ticket" minOccurs="0" maxOccurs="unbounded">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="ticket_type">
             
<xsd:simpleType>
               
<xsd:restriction base="xsd:string">
                 
<xsd:enumeration value="transmission"/>
                 
<xsd:enumeration value="generation"/>
               
</xsd:restriction>
             
</xsd:simpleType>
           
</xsd:element>
           
<xsd:element name="pjm_ticket_id" type="xsd:integer"/>
           
<xsd:element name="company_ticket_id" type="xsd:string" minOccurs="0"/>
           
<xsd:element name="scenario_id" type="xsd:integer"/>
           
<xsd:element name="status" type="xsd:string"/>
           
<xsd:element name="title" type="xsd:string"/>
           
<xsd:element name="mitigation_status" type="xsd:string" minOccurs="0"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="scenario" minOccurs="0" maxOccurs="unbounded">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="scenario_id" type="xsd:integer"/>
           
<xsd:element name="title" type="xsd:string"/>
           
<xsd:element name="mitigation_status" type="xsd:string" minOccurs="0"/>
           
<xsd:element name="potential_gap" minOccurs="0" maxOccurs="unbounded">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="interval_start">
                   
<xsd:complexType>
                     
<xsd:sequence>
                       
<xsd:element ref="date"/>
                       
<xsd:element ref="time"/>
                     
</xsd:sequence>
                   
</xsd:complexType>
                 
</xsd:element>
                 
<xsd:element name="interval_end">
                   
<xsd:complexType>
                     
<xsd:sequence>
                       
<xsd:element ref="date"/>
                       
<xsd:element ref="time"/>
                     
</xsd:sequence>
                   
</xsd:complexType>
                 
</xsd:element>
                 
<xsd:element name="actual_out" type="xsd:int"/>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="gen_ticket" minOccurs="0" maxOccurs="unbounded">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="pjm_ticket_id" type="xsd:integer"/>
                 
<xsd:element name="company_ticket_id" type="xsd:string" minOccurs="0"/>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element conflict/ticket
diagram transticreview_p2.png
properties
minOcc 0
maxOcc unbounded
content complex
children ticket_type pjm_ticket_id company_ticket_id scenario_id status title mitigation_status
source <xsd:element name="ticket" minOccurs="0" maxOccurs="unbounded">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="ticket_type">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:string">
           
<xsd:enumeration value="transmission"/>
           
<xsd:enumeration value="generation"/>
         
</xsd:restriction>
       
</xsd:simpleType>
     
</xsd:element>
     
<xsd:element name="pjm_ticket_id" type="xsd:integer"/>
     
<xsd:element name="company_ticket_id" type="xsd:string" minOccurs="0"/>
     
<xsd:element name="scenario_id" type="xsd:integer"/>
     
<xsd:element name="status" type="xsd:string"/>
     
<xsd:element name="title" type="xsd:string"/>
     
<xsd:element name="mitigation_status" type="xsd:string" minOccurs="0"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element conflict/ticket/ticket_type
diagram transticreview_p3.png
type restriction of xsd:string
properties
content simple
facets
Kind Value Annotation
enumeration transmission
enumeration generation
source <xsd:element name="ticket_type">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:string">
     
<xsd:enumeration value="transmission"/>
     
<xsd:enumeration value="generation"/>
   
</xsd:restriction>
 
</xsd:simpleType>
</xsd:element>

element conflict/ticket/pjm_ticket_id
diagram transticreview_p4.png
type xsd:integer
properties
content simple
source <xsd:element name="pjm_ticket_id" type="xsd:integer"/>

element conflict/ticket/company_ticket_id
diagram transticreview_p5.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="company_ticket_id" type="xsd:string" minOccurs="0"/>

element conflict/ticket/scenario_id
diagram transticreview_p6.png
type xsd:integer
properties
content simple
source <xsd:element name="scenario_id" type="xsd:integer"/>

element conflict/ticket/status
diagram transticreview_p7.png
type xsd:string
properties
content simple
source <xsd:element name="status" type="xsd:string"/>

element conflict/ticket/title
diagram transticreview_p8.png
type xsd:string
properties
content simple
source <xsd:element name="title" type="xsd:string"/>

element conflict/ticket/mitigation_status
diagram transticreview_p9.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="mitigation_status" type="xsd:string" minOccurs="0"/>

element conflict/scenario
diagram transticreview_p10.png
properties
minOcc 0
maxOcc unbounded
content complex
children scenario_id title mitigation_status potential_gap gen_ticket
source <xsd:element name="scenario" minOccurs="0" maxOccurs="unbounded">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="scenario_id" type="xsd:integer"/>
     
<xsd:element name="title" type="xsd:string"/>
     
<xsd:element name="mitigation_status" type="xsd:string" minOccurs="0"/>
     
<xsd:element name="potential_gap" minOccurs="0" maxOccurs="unbounded">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="interval_start">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element ref="date"/>
                 
<xsd:element ref="time"/>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="interval_end">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element ref="date"/>
                 
<xsd:element ref="time"/>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="actual_out" type="xsd:int"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="gen_ticket" minOccurs="0" maxOccurs="unbounded">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="pjm_ticket_id" type="xsd:integer"/>
           
<xsd:element name="company_ticket_id" type="xsd:string" minOccurs="0"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element conflict/scenario/scenario_id
diagram transticreview_p11.png
type xsd:integer
properties
content simple
source <xsd:element name="scenario_id" type="xsd:integer"/>

element conflict/scenario/title
diagram transticreview_p12.png
type xsd:string
properties
content simple
source <xsd:element name="title" type="xsd:string"/>

element conflict/scenario/mitigation_status
diagram transticreview_p13.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="mitigation_status" type="xsd:string" minOccurs="0"/>

element conflict/scenario/potential_gap
diagram transticreview_p14.png
properties
minOcc 0
maxOcc unbounded
content complex
children interval_start interval_end actual_out
source <xsd:element name="potential_gap" minOccurs="0" maxOccurs="unbounded">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="interval_start">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element ref="date"/>
           
<xsd:element ref="time"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="interval_end">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element ref="date"/>
           
<xsd:element ref="time"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="actual_out" type="xsd:int"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element conflict/scenario/potential_gap/interval_start
diagram transticreview_p15.png
properties
content complex
children date time
source <xsd:element name="interval_start">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element ref="date"/>
     
<xsd:element ref="time"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element conflict/scenario/potential_gap/interval_end
diagram transticreview_p16.png
properties
content complex
children date time
source <xsd:element name="interval_end">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element ref="date"/>
     
<xsd:element ref="time"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element conflict/scenario/potential_gap/actual_out
diagram transticreview_p17.png
type xsd:int
properties
content simple
source <xsd:element name="actual_out" type="xsd:int"/>

element conflict/scenario/gen_ticket
diagram transticreview_p18.png
properties
minOcc 0
maxOcc unbounded
content complex
children pjm_ticket_id company_ticket_id
source <xsd:element name="gen_ticket" minOccurs="0" maxOccurs="unbounded">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="pjm_ticket_id" type="xsd:integer"/>
     
<xsd:element name="company_ticket_id" type="xsd:string" minOccurs="0"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element conflict/scenario/gen_ticket/pjm_ticket_id
diagram transticreview_p19.png
type xsd:integer
properties
content simple
source <xsd:element name="pjm_ticket_id" type="xsd:integer"/>

element conflict/scenario/gen_ticket/company_ticket_id
diagram transticreview_p20.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="company_ticket_id" type="xsd:string" minOccurs="0"/>

element cutInTask
diagram transticreview_p21.png
properties
content complex
children name status
used by
element edart/transticreview/cutInInfo
source <xsd:element name="cutInTask">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="name" type="xsd:string"/>
     
<xsd:element name="status" type="xsd:string"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element cutInTask/name
diagram transticreview_p22.png
type xsd:string
properties
content simple
source <xsd:element name="name" type="xsd:string"/>

element cutInTask/status
diagram transticreview_p23.png
type xsd:string
properties
content simple
source <xsd:element name="status" type="xsd:string"/>

element date
diagram transticreview_p24.png
type xsd:string
properties
content simple
used by
elements edart/transticreview/company_actuals/interval_definition/interval_end interval_definition/interval_end conflict/scenario/potential_gap/interval_end edart/transticreview/company_actuals/interval_definition/interval_start interval_definition/interval_start conflict/scenario/potential_gap/interval_start
source <xsd:element name="date" type="xsd:string"/>

element edart
diagram transticreview_p25.png
properties
content complex
children error warning transticreview
source <xsd:element name="edart">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="error" type="xsd:string" minOccurs="0" maxOccurs="unbounded"/>
     
<xsd:element name="warning" type="xsd:string" minOccurs="0"/>
     
<xsd:element name="transticreview" maxOccurs="unbounded">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="error" type="xsd:string" minOccurs="0" maxOccurs="unbounded"/>
           
<xsd:element name="warning" type="xsd:string" minOccurs="0"/>
           
<xsd:element name="company_name" type="xsd:string" minOccurs="0"/>
           
<xsd:element name="pjm_ticket_id" type="xsd:integer"/>
           
<xsd:element name="company_ticket_id" minOccurs="0">
             
<xsd:simpleType>
               
<xsd:restriction base="xsd:string">
                 
<xsd:minLength value="1"/>
                 
<xsd:maxLength value="30"/>
               
</xsd:restriction>
             
</xsd:simpleType>
           
</xsd:element>
           
<xsd:element name="description" type="xsd:string"/>
           
<xsd:element name="project_ids" type="xsd:string" minOccurs="0" maxOccurs="1"/>
           
<xsd:element name="pjm_comments" minOccurs="0">
             
<xsd:simpleType>
               
<xsd:restriction base="xsd:string"/>
             
</xsd:simpleType>
           
</xsd:element>
           
<xsd:element name="at_risk" type="xsd:boolean" minOccurs="0"/>
           
<xsd:element name="availability" type="xsd:string"/>
           
<xsd:element name="lock_status" type="xsd:string"/>
           
<xsd:element name="ticket_status" type="xsd:string" minOccurs="0"/>
           
<xsd:element name="history_log" minOccurs="0">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="ticketStatus" maxOccurs="unbounded">
                   
<xsd:complexType>
                     
<xsd:sequence>
                       
<xsd:element name="status" type="xsd:string"/>
                       
<xsd:element name="timestamp" type="xsd:string"/>
                       
<xsd:element name="user" type="xsd:string"/>
                     
</xsd:sequence>
                   
</xsd:complexType>
                 
</xsd:element>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="modeling_requests" type="modeling_requests"/>
           
<xsd:element ref="interval_definition"/>
           
<xsd:element name="outage_type">
             
<xsd:simpleType>
               
<xsd:restriction base="xsd:string">
                 
<xsd:enumeration value="DailyIncludingWeekends"/>
                 
<xsd:enumeration value="DailyNoWeekends"/>
                 
<xsd:enumeration value="DailyWeekendsOnly"/>
                 
<xsd:enumeration value="ContinuousNoWeekends"/>
                 
<xsd:enumeration value="Continuous"/>
                 
<xsd:enumeration value="EMS Tripped"/>
               
</xsd:restriction>
             
</xsd:simpleType>
           
</xsd:element>
           
<xsd:element name="ticket_type">
             
<xsd:complexType>
               
<xsd:attribute name="info" type="xsd:boolean" use="optional"/>
               
<xsd:attribute name="emergency" type="xsd:boolean" use="optional"/>
               
<xsd:attribute name="auto_reclose" type="xsd:boolean" use="optional"/>
               
<xsd:attribute name="potentially_incomplete" type="xsd:boolean"/>
               
<xsd:attribute name="directBilling" type="xsd:boolean"/>
               
<xsd:attribute name="directBillingDecline" type="xsd:boolean"/>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="study_note" type="xsd:string" minOccurs="0"/>
           
<xsd:element name="equipment" maxOccurs="unbounded">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="ta_id" type="xsd:string"/>
                 
<xsd:element name="warning" type="xsd:string" minOccurs="0"/>
                 
<xsd:element name="min_mvar" type="xsd:integer" minOccurs="0"/>
                 
<xsd:element name="max_mvar" type="xsd:integer" minOccurs="0"/>
                 
<xsd:element name="type" type="xsd:string" minOccurs="0"/>
                 
<xsd:element ref="interval_definition"/>
               
</xsd:sequence>
               
<xsd:attribute name="status" use="required">
                 
<xsd:simpleType>
                   
<xsd:restriction base="xsd:NMTOKEN">
                     
<xsd:enumeration value="C"/>
                     
<xsd:enumeration value="O"/>
                     
<xsd:enumeration value="E"/>
                     
<xsd:enumeration value="T"/>
                     
<xsd:enumeration value="R"/>
                     
<xsd:enumeration value="TR"/>
                     
<xsd:enumeration value="RE"/>
                   
</xsd:restriction>
                 
</xsd:simpleType>
               
</xsd:attribute>
               
<xsd:attribute name="primaryEquipFlag" type="xsd:boolean" use="optional"/>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="active_dates" minOccurs="0">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element ref="interval_definition" minOccurs="0" maxOccurs="unbounded"/>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="switch">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="interval_definition">
                   
<xsd:complexType>
                     
<xsd:sequence>
                       
<xsd:element name="interval_start">
                         
<xsd:complexType>
                           
<xsd:sequence>
                             
<xsd:element name="date">
                               
<xsd:simpleType>
                                 
<xsd:restriction base="xsd:string"/>
                               
</xsd:simpleType>
                             
</xsd:element>
                             
<xsd:element name="time">
                               
<xsd:simpleType>
                                 
<xsd:restriction base="xsd:string"/>
                               
</xsd:simpleType>
                             
</xsd:element>
                           
</xsd:sequence>
                         
</xsd:complexType>
                       
</xsd:element>
                     
</xsd:sequence>
                   
</xsd:complexType>
                 
</xsd:element>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="congestionExpected" type="xsd:boolean" minOccurs="0"/>
           
<xsd:element name="submittedOnTime" type="xsd:boolean" minOccurs="0"/>
           
<xsd:element name="submitOnTimeComments" type="xsd:string" minOccurs="0"/>
           
<xsd:element name="vegetationFlag" type="xsd:boolean" minOccurs="0"/>
           
<xsd:element name="cause" maxOccurs="unbounded">
             
<xsd:complexType>
               
<xsd:simpleContent>
                 
<xsd:extension base="xsd:int">
                   
<xsd:attribute name="description" type="xsd:string"/>
                 
</xsd:extension>
               
</xsd:simpleContent>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="totalSystemImpacts" type="xsd:integer" minOccurs="0"/>
           
<xsd:element name="unmitigatedSystemImpacts" type="xsd:integer" minOccurs="0"/>
           
<xsd:element name="systemImpacts" minOccurs="0">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="impact" maxOccurs="unbounded">
                   
<xsd:complexType>
                     
<xsd:sequence>
                       
<xsd:element name="impactTitle" type="xsd:string"/>
                       
<xsd:element name="impactDescription" type="xsd:string"/>
                       
<xsd:element name="mitigationStatus" type="xsd:string" minOccurs="0"/>
                     
</xsd:sequence>
                   
</xsd:complexType>
                 
</xsd:element>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="cutInFlag" type="xsd:string" minOccurs="0"/>
           
<xsd:element name="cutInInfo" minOccurs="0">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="cutInTitle" type="xsd:string" minOccurs="0"/>
                 
<xsd:element name="cutInStatus" type="xsd:string" minOccurs="0"/>
                 
<xsd:element ref="cutInTask" minOccurs="0" maxOccurs="unbounded"/>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="marketSensitiveFlag" type="xsd:boolean" minOccurs="0"/>
           
<xsd:element name="nerctads" minOccurs="0">
             
<xsd:complexType>
               
<xsd:choice>
                 
<xsd:element name="planned">
                   
<xsd:simpleType>
                     
<xsd:restriction base="xsd:string">
                       
<xsd:enumeration value="Maintenance and Construction"/>
                       
<xsd:enumeration value="Other Planned Outage"/>
                       
<xsd:enumeration value="Third Party Request"/>
                     
</xsd:restriction>
                   
</xsd:simpleType>
                 
</xsd:element>
                 
<xsd:element name="operational">
                   
<xsd:simpleType>
                     
<xsd:restriction base="xsd:string">
                       
<xsd:enumeration value="Emergency"/>
                       
<xsd:enumeration value="Other Operational Outage"/>
                       
<xsd:enumeration value="System Operating Limit Mitigation, ex Voltage"/>
                       
<xsd:enumeration value="System Voltage Limit Mitigation"/>
                       
<xsd:enumeration value="N/A"/>
                       
<xsd:enumeration value="Human Error"/>
                     
</xsd:restriction>
                   
</xsd:simpleType>
                 
</xsd:element>
                 
<xsd:element name="autoReclose">
                   
<xsd:complexType>
                     
<xsd:sequence>
                       
<xsd:element name="faultType">
                         
<xsd:simpleType>
                           
<xsd:restriction base="xsd:integer">
                             
<xsd:minInclusive value="0"/>
                             
<xsd:maxInclusive value="5"/>
                           
</xsd:restriction>
                         
</xsd:simpleType>
                       
</xsd:element>
                       
<xsd:element name="outageInitCode">
                         
<xsd:simpleType>
                           
<xsd:restriction base="xsd:integer">
                             
<xsd:minInclusive value="0"/>
                             
<xsd:maxInclusive value="5"/>
                           
</xsd:restriction>
                         
</xsd:simpleType>
                       
</xsd:element>
                       
<xsd:element name="initCauseCode">
                         
<xsd:simpleType>
                           
<xsd:restriction base="xsd:integer">
                             
<xsd:minInclusive value="0"/>
                             
<xsd:maxInclusive value="17"/>
                           
</xsd:restriction>
                         
</xsd:simpleType>
                       
</xsd:element>
                       
<xsd:element name="sustainedCauseCode">
                         
<xsd:simpleType>
                           
<xsd:restriction base="xsd:integer">
                             
<xsd:minInclusive value="0"/>
                             
<xsd:maxInclusive value="18"/>
                           
</xsd:restriction>
                         
</xsd:simpleType>
                       
</xsd:element>
                       
<xsd:element name="outageModeCode">
                         
<xsd:simpleType>
                           
<xsd:restriction base="xsd:integer">
                             
<xsd:minInclusive value="0"/>
                             
<xsd:maxInclusive value="5"/>
                           
</xsd:restriction>
                         
</xsd:simpleType>
                       
</xsd:element>
                     
</xsd:sequence>
                   
</xsd:complexType>
                 
</xsd:element>
               
</xsd:choice>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="datelogs" minOccurs="0">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="datelog" minOccurs="0" maxOccurs="unbounded">
                   
<xsd:complexType>
                     
<xsd:sequence>
                       
<xsd:element ref="interval_definition"/>
                       
<xsd:element name="timestamp" type="xsd:string"/>
                       
<xsd:element name="currentFlag" type="xsd:integer"/>
                       
<xsd:element name="user" type="xsd:string"/>
                     
</xsd:sequence>
                   
</xsd:complexType>
                 
</xsd:element>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="rtepQueueNumber" minOccurs="0">
             
<xsd:simpleType>
               
<xsd:restriction base="xsd:string">
                 
<xsd:maxLength value="50"/>
               
</xsd:restriction>
             
</xsd:simpleType>
           
</xsd:element>
           
<xsd:element name="totalConflicts" type="xsd:integer" minOccurs="0"/>
           
<xsd:element name="unmitigatedConflicts" type="xsd:integer" minOccurs="0"/>
           
<xsd:element ref="conflict" minOccurs="0" maxOccurs="2"/>
           
<xsd:element name="company_actuals" minOccurs="0">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="interval_definition" maxOccurs="unbounded">
                   
<xsd:complexType>
                     
<xsd:sequence>
                       
<xsd:element name="interval_start">
                         
<xsd:complexType>
                           
<xsd:sequence>
                             
<xsd:element ref="date"/>
                             
<xsd:element ref="time"/>
                           
</xsd:sequence>
                         
</xsd:complexType>
                       
</xsd:element>
                       
<xsd:element name="interval_end" minOccurs="0">
                         
<xsd:complexType>
                           
<xsd:sequence>
                             
<xsd:element ref="date"/>
                             
<xsd:element ref="time"/>
                           
</xsd:sequence>
                         
</xsd:complexType>
                       
</xsd:element>
                     
</xsd:sequence>
                   
</xsd:complexType>
                 
</xsd:element>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="fileAttachmentCount" type="xsd:unsignedInt" minOccurs="0"/>
           
<xsd:element name="fileList" minOccurs="0">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="file" maxOccurs="unbounded">
                   
<xsd:complexType>
                     
<xsd:sequence>
                       
<xsd:element name="fileName" type="xsd:string"/>
                     
</xsd:sequence>
                   
</xsd:complexType>
                 
</xsd:element>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="fileAttachments" minOccurs="0">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="attachment" type="xsd:string" maxOccurs="unbounded"/>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="equipment_default" type="equipment_default"/>
           
<xsd:element name="takeout_restore" type="takeout_restore"/>
           
<xsd:element name="restplan" type="restplan" minOccurs="0"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/error
diagram transticreview_p26.png
type xsd:string
properties
minOcc 0
maxOcc unbounded
content simple
source <xsd:element name="error" type="xsd:string" minOccurs="0" maxOccurs="unbounded"/>

element edart/warning
diagram transticreview_p27.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="warning" type="xsd:string" minOccurs="0"/>

element edart/transticreview
diagram transticreview_p28.png
properties
minOcc 1
maxOcc unbounded
content complex
children error warning company_name pjm_ticket_id company_ticket_id description project_ids pjm_comments at_risk availability lock_status ticket_status history_log modeling_requests interval_definition outage_type ticket_type study_note equipment active_dates switch congestionExpected submittedOnTime submitOnTimeComments vegetationFlag cause totalSystemImpacts unmitigatedSystemImpacts systemImpacts cutInFlag cutInInfo marketSensitiveFlag nerctads datelogs rtepQueueNumber totalConflicts unmitigatedConflicts conflict company_actuals fileAttachmentCount fileList fileAttachments equipment_default takeout_restore restplan
source <xsd:element name="transticreview" maxOccurs="unbounded">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="error" type="xsd:string" minOccurs="0" maxOccurs="unbounded"/>
     
<xsd:element name="warning" type="xsd:string" minOccurs="0"/>
     
<xsd:element name="company_name" type="xsd:string" minOccurs="0"/>
     
<xsd:element name="pjm_ticket_id" type="xsd:integer"/>
     
<xsd:element name="company_ticket_id" minOccurs="0">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:string">
           
<xsd:minLength value="1"/>
           
<xsd:maxLength value="30"/>
         
</xsd:restriction>
       
</xsd:simpleType>
     
</xsd:element>
     
<xsd:element name="description" type="xsd:string"/>
     
<xsd:element name="project_ids" type="xsd:string" minOccurs="0" maxOccurs="1"/>
     
<xsd:element name="pjm_comments" minOccurs="0">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:string"/>
       
</xsd:simpleType>
     
</xsd:element>
     
<xsd:element name="at_risk" type="xsd:boolean" minOccurs="0"/>
     
<xsd:element name="availability" type="xsd:string"/>
     
<xsd:element name="lock_status" type="xsd:string"/>
     
<xsd:element name="ticket_status" type="xsd:string" minOccurs="0"/>
     
<xsd:element name="history_log" minOccurs="0">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="ticketStatus" maxOccurs="unbounded">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="status" type="xsd:string"/>
                 
<xsd:element name="timestamp" type="xsd:string"/>
                 
<xsd:element name="user" type="xsd:string"/>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="modeling_requests" type="modeling_requests"/>
     
<xsd:element ref="interval_definition"/>
     
<xsd:element name="outage_type">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:string">
           
<xsd:enumeration value="DailyIncludingWeekends"/>
           
<xsd:enumeration value="DailyNoWeekends"/>
           
<xsd:enumeration value="DailyWeekendsOnly"/>
           
<xsd:enumeration value="ContinuousNoWeekends"/>
           
<xsd:enumeration value="Continuous"/>
           
<xsd:enumeration value="EMS Tripped"/>
         
</xsd:restriction>
       
</xsd:simpleType>
     
</xsd:element>
     
<xsd:element name="ticket_type">
       
<xsd:complexType>
         
<xsd:attribute name="info" type="xsd:boolean" use="optional"/>
         
<xsd:attribute name="emergency" type="xsd:boolean" use="optional"/>
         
<xsd:attribute name="auto_reclose" type="xsd:boolean" use="optional"/>
         
<xsd:attribute name="potentially_incomplete" type="xsd:boolean"/>
         
<xsd:attribute name="directBilling" type="xsd:boolean"/>
         
<xsd:attribute name="directBillingDecline" type="xsd:boolean"/>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="study_note" type="xsd:string" minOccurs="0"/>
     
<xsd:element name="equipment" maxOccurs="unbounded">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="ta_id" type="xsd:string"/>
           
<xsd:element name="warning" type="xsd:string" minOccurs="0"/>
           
<xsd:element name="min_mvar" type="xsd:integer" minOccurs="0"/>
           
<xsd:element name="max_mvar" type="xsd:integer" minOccurs="0"/>
           
<xsd:element name="type" type="xsd:string" minOccurs="0"/>
           
<xsd:element ref="interval_definition"/>
         
</xsd:sequence>
         
<xsd:attribute name="status" use="required">
           
<xsd:simpleType>
             
<xsd:restriction base="xsd:NMTOKEN">
               
<xsd:enumeration value="C"/>
               
<xsd:enumeration value="O"/>
               
<xsd:enumeration value="E"/>
               
<xsd:enumeration value="T"/>
               
<xsd:enumeration value="R"/>
               
<xsd:enumeration value="TR"/>
               
<xsd:enumeration value="RE"/>
             
</xsd:restriction>
           
</xsd:simpleType>
         
</xsd:attribute>
         
<xsd:attribute name="primaryEquipFlag" type="xsd:boolean" use="optional"/>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="active_dates" minOccurs="0">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element ref="interval_definition" minOccurs="0" maxOccurs="unbounded"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="switch">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="interval_definition">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="interval_start">
                   
<xsd:complexType>
                     
<xsd:sequence>
                       
<xsd:element name="date">
                         
<xsd:simpleType>
                           
<xsd:restriction base="xsd:string"/>
                         
</xsd:simpleType>
                       
</xsd:element>
                       
<xsd:element name="time">
                         
<xsd:simpleType>
                           
<xsd:restriction base="xsd:string"/>
                         
</xsd:simpleType>
                       
</xsd:element>
                     
</xsd:sequence>
                   
</xsd:complexType>
                 
</xsd:element>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="congestionExpected" type="xsd:boolean" minOccurs="0"/>
     
<xsd:element name="submittedOnTime" type="xsd:boolean" minOccurs="0"/>
     
<xsd:element name="submitOnTimeComments" type="xsd:string" minOccurs="0"/>
     
<xsd:element name="vegetationFlag" type="xsd:boolean" minOccurs="0"/>
     
<xsd:element name="cause" maxOccurs="unbounded">
       
<xsd:complexType>
         
<xsd:simpleContent>
           
<xsd:extension base="xsd:int">
             
<xsd:attribute name="description" type="xsd:string"/>
           
</xsd:extension>
         
</xsd:simpleContent>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="totalSystemImpacts" type="xsd:integer" minOccurs="0"/>
     
<xsd:element name="unmitigatedSystemImpacts" type="xsd:integer" minOccurs="0"/>
     
<xsd:element name="systemImpacts" minOccurs="0">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="impact" maxOccurs="unbounded">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="impactTitle" type="xsd:string"/>
                 
<xsd:element name="impactDescription" type="xsd:string"/>
                 
<xsd:element name="mitigationStatus" type="xsd:string" minOccurs="0"/>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="cutInFlag" type="xsd:string" minOccurs="0"/>
     
<xsd:element name="cutInInfo" minOccurs="0">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="cutInTitle" type="xsd:string" minOccurs="0"/>
           
<xsd:element name="cutInStatus" type="xsd:string" minOccurs="0"/>
           
<xsd:element ref="cutInTask" minOccurs="0" maxOccurs="unbounded"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="marketSensitiveFlag" type="xsd:boolean" minOccurs="0"/>
     
<xsd:element name="nerctads" minOccurs="0">
       
<xsd:complexType>
         
<xsd:choice>
           
<xsd:element name="planned">
             
<xsd:simpleType>
               
<xsd:restriction base="xsd:string">
                 
<xsd:enumeration value="Maintenance and Construction"/>
                 
<xsd:enumeration value="Other Planned Outage"/>
                 
<xsd:enumeration value="Third Party Request"/>
               
</xsd:restriction>
             
</xsd:simpleType>
           
</xsd:element>
           
<xsd:element name="operational">
             
<xsd:simpleType>
               
<xsd:restriction base="xsd:string">
                 
<xsd:enumeration value="Emergency"/>
                 
<xsd:enumeration value="Other Operational Outage"/>
                 
<xsd:enumeration value="System Operating Limit Mitigation, ex Voltage"/>
                 
<xsd:enumeration value="System Voltage Limit Mitigation"/>
                 
<xsd:enumeration value="N/A"/>
                 
<xsd:enumeration value="Human Error"/>
               
</xsd:restriction>
             
</xsd:simpleType>
           
</xsd:element>
           
<xsd:element name="autoReclose">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="faultType">
                   
<xsd:simpleType>
                     
<xsd:restriction base="xsd:integer">
                       
<xsd:minInclusive value="0"/>
                       
<xsd:maxInclusive value="5"/>
                     
</xsd:restriction>
                   
</xsd:simpleType>
                 
</xsd:element>
                 
<xsd:element name="outageInitCode">
                   
<xsd:simpleType>
                     
<xsd:restriction base="xsd:integer">
                       
<xsd:minInclusive value="0"/>
                       
<xsd:maxInclusive value="5"/>
                     
</xsd:restriction>
                   
</xsd:simpleType>
                 
</xsd:element>
                 
<xsd:element name="initCauseCode">
                   
<xsd:simpleType>
                     
<xsd:restriction base="xsd:integer">
                       
<xsd:minInclusive value="0"/>
                       
<xsd:maxInclusive value="17"/>
                     
</xsd:restriction>
                   
</xsd:simpleType>
                 
</xsd:element>
                 
<xsd:element name="sustainedCauseCode">
                   
<xsd:simpleType>
                     
<xsd:restriction base="xsd:integer">
                       
<xsd:minInclusive value="0"/>
                       
<xsd:maxInclusive value="18"/>
                     
</xsd:restriction>
                   
</xsd:simpleType>
                 
</xsd:element>
                 
<xsd:element name="outageModeCode">
                   
<xsd:simpleType>
                     
<xsd:restriction base="xsd:integer">
                       
<xsd:minInclusive value="0"/>
                       
<xsd:maxInclusive value="5"/>
                     
</xsd:restriction>
                   
</xsd:simpleType>
                 
</xsd:element>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
         
</xsd:choice>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="datelogs" minOccurs="0">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="datelog" minOccurs="0" maxOccurs="unbounded">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element ref="interval_definition"/>
                 
<xsd:element name="timestamp" type="xsd:string"/>
                 
<xsd:element name="currentFlag" type="xsd:integer"/>
                 
<xsd:element name="user" type="xsd:string"/>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="rtepQueueNumber" minOccurs="0">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:string">
           
<xsd:maxLength value="50"/>
         
</xsd:restriction>
       
</xsd:simpleType>
     
</xsd:element>
     
<xsd:element name="totalConflicts" type="xsd:integer" minOccurs="0"/>
     
<xsd:element name="unmitigatedConflicts" type="xsd:integer" minOccurs="0"/>
     
<xsd:element ref="conflict" minOccurs="0" maxOccurs="2"/>
     
<xsd:element name="company_actuals" minOccurs="0">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="interval_definition" maxOccurs="unbounded">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="interval_start">
                   
<xsd:complexType>
                     
<xsd:sequence>
                       
<xsd:element ref="date"/>
                       
<xsd:element ref="time"/>
                     
</xsd:sequence>
                   
</xsd:complexType>
                 
</xsd:element>
                 
<xsd:element name="interval_end" minOccurs="0">
                   
<xsd:complexType>
                     
<xsd:sequence>
                       
<xsd:element ref="date"/>
                       
<xsd:element ref="time"/>
                     
</xsd:sequence>
                   
</xsd:complexType>
                 
</xsd:element>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="fileAttachmentCount" type="xsd:unsignedInt" minOccurs="0"/>
     
<xsd:element name="fileList" minOccurs="0">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="file" maxOccurs="unbounded">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="fileName" type="xsd:string"/>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="fileAttachments" minOccurs="0">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="attachment" type="xsd:string" maxOccurs="unbounded"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="equipment_default" type="equipment_default"/>
     
<xsd:element name="takeout_restore" type="takeout_restore"/>
     
<xsd:element name="restplan" type="restplan" minOccurs="0"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/error
diagram transticreview_p29.png
type xsd:string
properties
minOcc 0
maxOcc unbounded
content simple
source <xsd:element name="error" type="xsd:string" minOccurs="0" maxOccurs="unbounded"/>

element edart/transticreview/warning
diagram transticreview_p30.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="warning" type="xsd:string" minOccurs="0"/>

element edart/transticreview/company_name
diagram transticreview_p31.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="company_name" type="xsd:string" minOccurs="0"/>

element edart/transticreview/pjm_ticket_id
diagram transticreview_p32.png
type xsd:integer
properties
content simple
source <xsd:element name="pjm_ticket_id" type="xsd:integer"/>

element edart/transticreview/company_ticket_id
diagram transticreview_p33.png
type restriction of xsd:string
properties
minOcc 0
maxOcc 1
content simple
facets
Kind Value Annotation
minLength 1
maxLength 30
source <xsd:element name="company_ticket_id" minOccurs="0">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:string">
     
<xsd:minLength value="1"/>
     
<xsd:maxLength value="30"/>
   
</xsd:restriction>
 
</xsd:simpleType>
</xsd:element>

element edart/transticreview/description
diagram transticreview_p34.png
type xsd:string
properties
content simple
source <xsd:element name="description" type="xsd:string"/>

element edart/transticreview/project_ids
diagram transticreview_p35.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="project_ids" type="xsd:string" minOccurs="0" maxOccurs="1"/>

element edart/transticreview/pjm_comments
diagram transticreview_p36.png
type restriction of xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="pjm_comments" minOccurs="0">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:string"/>
 
</xsd:simpleType>
</xsd:element>

element edart/transticreview/at_risk
diagram transticreview_p37.png
type xsd:boolean
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="at_risk" type="xsd:boolean" minOccurs="0"/>

element edart/transticreview/availability
diagram transticreview_p38.png
type xsd:string
properties
content simple
source <xsd:element name="availability" type="xsd:string"/>

element edart/transticreview/lock_status
diagram transticreview_p39.png
type xsd:string
properties
content simple
source <xsd:element name="lock_status" type="xsd:string"/>

element edart/transticreview/ticket_status
diagram transticreview_p40.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="ticket_status" type="xsd:string" minOccurs="0"/>

element edart/transticreview/history_log
diagram transticreview_p41.png
properties
minOcc 0
maxOcc 1
content complex
children ticketStatus
source <xsd:element name="history_log" minOccurs="0">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="ticketStatus" maxOccurs="unbounded">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="status" type="xsd:string"/>
           
<xsd:element name="timestamp" type="xsd:string"/>
           
<xsd:element name="user" type="xsd:string"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/history_log/ticketStatus
diagram transticreview_p42.png
properties
minOcc 1
maxOcc unbounded
content complex
children status timestamp user
source <xsd:element name="ticketStatus" maxOccurs="unbounded">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="status" type="xsd:string"/>
     
<xsd:element name="timestamp" type="xsd:string"/>
     
<xsd:element name="user" type="xsd:string"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/history_log/ticketStatus/status
diagram transticreview_p43.png
type xsd:string
properties
content simple
source <xsd:element name="status" type="xsd:string"/>

element edart/transticreview/history_log/ticketStatus/timestamp
diagram transticreview_p44.png
type xsd:string
properties
content simple
source <xsd:element name="timestamp" type="xsd:string"/>

element edart/transticreview/history_log/ticketStatus/user
diagram transticreview_p45.png
type xsd:string
properties
content simple
source <xsd:element name="user" type="xsd:string"/>

element edart/transticreview/modeling_requests
diagram transticreview_p46.png
type modeling_requests
properties
content complex
children modeling_request
source <xsd:element name="modeling_requests" type="modeling_requests"/>

element edart/transticreview/outage_type
diagram transticreview_p47.png
type restriction of xsd:string
properties
content simple
facets
Kind Value Annotation
enumeration DailyIncludingWeekends
enumeration DailyNoWeekends
enumeration DailyWeekendsOnly
enumeration ContinuousNoWeekends
enumeration Continuous
enumeration EMS Tripped
source <xsd:element name="outage_type">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:string">
     
<xsd:enumeration value="DailyIncludingWeekends"/>
     
<xsd:enumeration value="DailyNoWeekends"/>
     
<xsd:enumeration value="DailyWeekendsOnly"/>
     
<xsd:enumeration value="ContinuousNoWeekends"/>
     
<xsd:enumeration value="Continuous"/>
     
<xsd:enumeration value="EMS Tripped"/>
   
</xsd:restriction>
 
</xsd:simpleType>
</xsd:element>

element edart/transticreview/ticket_type
diagram transticreview_p48.png
properties
content complex
attributes
Name  Type  Use  Default  Fixed  Annotation
info  xsd:boolean  optional      
emergency  xsd:boolean  optional      
auto_reclose  xsd:boolean  optional      
potentially_incomplete  xsd:boolean        
directBilling  xsd:boolean        
directBillingDecline  xsd:boolean        
source <xsd:element name="ticket_type">
 
<xsd:complexType>
   
<xsd:attribute name="info" type="xsd:boolean" use="optional"/>
   
<xsd:attribute name="emergency" type="xsd:boolean" use="optional"/>
   
<xsd:attribute name="auto_reclose" type="xsd:boolean" use="optional"/>
   
<xsd:attribute name="potentially_incomplete" type="xsd:boolean"/>
   
<xsd:attribute name="directBilling" type="xsd:boolean"/>
   
<xsd:attribute name="directBillingDecline" type="xsd:boolean"/>
 
</xsd:complexType>
</xsd:element>

attribute edart/transticreview/ticket_type/@info
type xsd:boolean
properties
use optional
source <xsd:attribute name="info" type="xsd:boolean" use="optional"/>

attribute edart/transticreview/ticket_type/@emergency
type xsd:boolean
properties
use optional
source <xsd:attribute name="emergency" type="xsd:boolean" use="optional"/>

attribute edart/transticreview/ticket_type/@auto_reclose
type xsd:boolean
properties
use optional
source <xsd:attribute name="auto_reclose" type="xsd:boolean" use="optional"/>

attribute edart/transticreview/ticket_type/@potentially_incomplete
type xsd:boolean
source <xsd:attribute name="potentially_incomplete" type="xsd:boolean"/>

attribute edart/transticreview/ticket_type/@directBilling
type xsd:boolean
source <xsd:attribute name="directBilling" type="xsd:boolean"/>

attribute edart/transticreview/ticket_type/@directBillingDecline
type xsd:boolean
source <xsd:attribute name="directBillingDecline" type="xsd:boolean"/>

element edart/transticreview/study_note
diagram transticreview_p49.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="study_note" type="xsd:string" minOccurs="0"/>

element edart/transticreview/equipment
diagram transticreview_p50.png
properties
minOcc 1
maxOcc unbounded
content complex
children ta_id warning min_mvar max_mvar type interval_definition
attributes
Name  Type  Use  Default  Fixed  Annotation
status  derived by: xsd:NMTOKEN  required      
primaryEquipFlag  xsd:boolean  optional      
source <xsd:element name="equipment" maxOccurs="unbounded">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="ta_id" type="xsd:string"/>
     
<xsd:element name="warning" type="xsd:string" minOccurs="0"/>
     
<xsd:element name="min_mvar" type="xsd:integer" minOccurs="0"/>
     
<xsd:element name="max_mvar" type="xsd:integer" minOccurs="0"/>
     
<xsd:element name="type" type="xsd:string" minOccurs="0"/>
     
<xsd:element ref="interval_definition"/>
   
</xsd:sequence>
   
<xsd:attribute name="status" use="required">
     
<xsd:simpleType>
       
<xsd:restriction base="xsd:NMTOKEN">
         
<xsd:enumeration value="C"/>
         
<xsd:enumeration value="O"/>
         
<xsd:enumeration value="E"/>
         
<xsd:enumeration value="T"/>
         
<xsd:enumeration value="R"/>
         
<xsd:enumeration value="TR"/>
         
<xsd:enumeration value="RE"/>
       
</xsd:restriction>
     
</xsd:simpleType>
   
</xsd:attribute>
   
<xsd:attribute name="primaryEquipFlag" type="xsd:boolean" use="optional"/>
 
</xsd:complexType>
</xsd:element>

attribute edart/transticreview/equipment/@status
type restriction of xsd:NMTOKEN
properties
use required
facets
Kind Value Annotation
enumeration C
enumeration O
enumeration E
enumeration T
enumeration R
enumeration TR
enumeration RE
source <xsd:attribute name="status" use="required">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:NMTOKEN">
     
<xsd:enumeration value="C"/>
     
<xsd:enumeration value="O"/>
     
<xsd:enumeration value="E"/>
     
<xsd:enumeration value="T"/>
     
<xsd:enumeration value="R"/>
     
<xsd:enumeration value="TR"/>
     
<xsd:enumeration value="RE"/>
   
</xsd:restriction>
 
</xsd:simpleType>
</xsd:attribute>

attribute edart/transticreview/equipment/@primaryEquipFlag
type xsd:boolean
properties
use optional
source <xsd:attribute name="primaryEquipFlag" type="xsd:boolean" use="optional"/>

element edart/transticreview/equipment/ta_id
diagram transticreview_p51.png
type xsd:string
properties
content simple
source <xsd:element name="ta_id" type="xsd:string"/>

element edart/transticreview/equipment/warning
diagram transticreview_p52.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="warning" type="xsd:string" minOccurs="0"/>

element edart/transticreview/equipment/min_mvar
diagram transticreview_p53.png
type xsd:integer
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="min_mvar" type="xsd:integer" minOccurs="0"/>

element edart/transticreview/equipment/max_mvar
diagram transticreview_p54.png
type xsd:integer
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="max_mvar" type="xsd:integer" minOccurs="0"/>

element edart/transticreview/equipment/type
diagram transticreview_p55.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="type" type="xsd:string" minOccurs="0"/>

element edart/transticreview/active_dates
diagram transticreview_p56.png
properties
minOcc 0
maxOcc 1
content complex
children interval_definition
source <xsd:element name="active_dates" minOccurs="0">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element ref="interval_definition" minOccurs="0" maxOccurs="unbounded"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/switch
diagram transticreview_p57.png
properties
content complex
children interval_definition
source <xsd:element name="switch">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="interval_definition">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="interval_start">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element name="date">
                   
<xsd:simpleType>
                     
<xsd:restriction base="xsd:string"/>
                   
</xsd:simpleType>
                 
</xsd:element>
                 
<xsd:element name="time">
                   
<xsd:simpleType>
                     
<xsd:restriction base="xsd:string"/>
                   
</xsd:simpleType>
                 
</xsd:element>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/switch/interval_definition
diagram transticreview_p58.png
properties
content complex
children interval_start
used by
elements edart/transticreview/active_dates edart/transticreview/datelogs/datelog edart/transticreview/equipment edart/transticreview
source <xsd:element name="interval_definition">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="interval_start">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="date">
             
<xsd:simpleType>
               
<xsd:restriction base="xsd:string"/>
             
</xsd:simpleType>
           
</xsd:element>
           
<xsd:element name="time">
             
<xsd:simpleType>
               
<xsd:restriction base="xsd:string"/>
             
</xsd:simpleType>
           
</xsd:element>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/switch/interval_definition/interval_start
diagram transticreview_p59.png
properties
content complex
children date time
source <xsd:element name="interval_start">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="date">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:string"/>
       
</xsd:simpleType>
     
</xsd:element>
     
<xsd:element name="time">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:string"/>
       
</xsd:simpleType>
     
</xsd:element>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/switch/interval_definition/interval_start/date
diagram transticreview_p60.png
type restriction of xsd:string
properties
content simple
used by
elements edart/transticreview/company_actuals/interval_definition/interval_end interval_definition/interval_end conflict/scenario/potential_gap/interval_end edart/transticreview/company_actuals/interval_definition/interval_start interval_definition/interval_start conflict/scenario/potential_gap/interval_start
source <xsd:element name="date">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:string"/>
 
</xsd:simpleType>
</xsd:element>

element edart/transticreview/switch/interval_definition/interval_start/time
diagram transticreview_p61.png
type restriction of xsd:string
properties
content simple
used by
elements edart/transticreview/company_actuals/interval_definition/interval_end interval_definition/interval_end conflict/scenario/potential_gap/interval_end edart/transticreview/company_actuals/interval_definition/interval_start interval_definition/interval_start conflict/scenario/potential_gap/interval_start
source <xsd:element name="time">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:string"/>
 
</xsd:simpleType>
</xsd:element>

element edart/transticreview/congestionExpected
diagram transticreview_p62.png
type xsd:boolean
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="congestionExpected" type="xsd:boolean" minOccurs="0"/>

element edart/transticreview/submittedOnTime
diagram transticreview_p63.png
type xsd:boolean
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="submittedOnTime" type="xsd:boolean" minOccurs="0"/>

element edart/transticreview/submitOnTimeComments
diagram transticreview_p64.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="submitOnTimeComments" type="xsd:string" minOccurs="0"/>

element edart/transticreview/vegetationFlag
diagram transticreview_p65.png
type xsd:boolean
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="vegetationFlag" type="xsd:boolean" minOccurs="0"/>

element edart/transticreview/cause
diagram transticreview_p66.png
type extension of xsd:int
properties
minOcc 1
maxOcc unbounded
content complex
attributes
Name  Type  Use  Default  Fixed  Annotation
description  xsd:string        
source <xsd:element name="cause" maxOccurs="unbounded">
 
<xsd:complexType>
   
<xsd:simpleContent>
     
<xsd:extension base="xsd:int">
       
<xsd:attribute name="description" type="xsd:string"/>
     
</xsd:extension>
   
</xsd:simpleContent>
 
</xsd:complexType>
</xsd:element>

attribute edart/transticreview/cause/@description
type xsd:string
source <xsd:attribute name="description" type="xsd:string"/>

element edart/transticreview/totalSystemImpacts
diagram transticreview_p67.png
type xsd:integer
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="totalSystemImpacts" type="xsd:integer" minOccurs="0"/>

element edart/transticreview/unmitigatedSystemImpacts
diagram transticreview_p68.png
type xsd:integer
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="unmitigatedSystemImpacts" type="xsd:integer" minOccurs="0"/>

element edart/transticreview/systemImpacts
diagram transticreview_p69.png
properties
minOcc 0
maxOcc 1
content complex
children impact
source <xsd:element name="systemImpacts" minOccurs="0">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="impact" maxOccurs="unbounded">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="impactTitle" type="xsd:string"/>
           
<xsd:element name="impactDescription" type="xsd:string"/>
           
<xsd:element name="mitigationStatus" type="xsd:string" minOccurs="0"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/systemImpacts/impact
diagram transticreview_p70.png
properties
minOcc 1
maxOcc unbounded
content complex
children impactTitle impactDescription mitigationStatus
source <xsd:element name="impact" maxOccurs="unbounded">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="impactTitle" type="xsd:string"/>
     
<xsd:element name="impactDescription" type="xsd:string"/>
     
<xsd:element name="mitigationStatus" type="xsd:string" minOccurs="0"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/systemImpacts/impact/impactTitle
diagram transticreview_p71.png
type xsd:string
properties
content simple
source <xsd:element name="impactTitle" type="xsd:string"/>

element edart/transticreview/systemImpacts/impact/impactDescription
diagram transticreview_p72.png
type xsd:string
properties
content simple
source <xsd:element name="impactDescription" type="xsd:string"/>

element edart/transticreview/systemImpacts/impact/mitigationStatus
diagram transticreview_p73.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="mitigationStatus" type="xsd:string" minOccurs="0"/>

element edart/transticreview/cutInFlag
diagram transticreview_p74.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="cutInFlag" type="xsd:string" minOccurs="0"/>

element edart/transticreview/cutInInfo
diagram transticreview_p75.png
properties
minOcc 0
maxOcc 1
content complex
children cutInTitle cutInStatus cutInTask
source <xsd:element name="cutInInfo" minOccurs="0">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="cutInTitle" type="xsd:string" minOccurs="0"/>
     
<xsd:element name="cutInStatus" type="xsd:string" minOccurs="0"/>
     
<xsd:element ref="cutInTask" minOccurs="0" maxOccurs="unbounded"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/cutInInfo/cutInTitle
diagram transticreview_p76.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="cutInTitle" type="xsd:string" minOccurs="0"/>

element edart/transticreview/cutInInfo/cutInStatus
diagram transticreview_p77.png
type xsd:string
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="cutInStatus" type="xsd:string" minOccurs="0"/>

element edart/transticreview/marketSensitiveFlag
diagram transticreview_p78.png
type xsd:boolean
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="marketSensitiveFlag" type="xsd:boolean" minOccurs="0"/>

element edart/transticreview/nerctads
diagram transticreview_p79.png
properties
minOcc 0
maxOcc 1
content complex
children planned operational autoReclose
source <xsd:element name="nerctads" minOccurs="0">
 
<xsd:complexType>
   
<xsd:choice>
     
<xsd:element name="planned">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:string">
           
<xsd:enumeration value="Maintenance and Construction"/>
           
<xsd:enumeration value="Other Planned Outage"/>
           
<xsd:enumeration value="Third Party Request"/>
         
</xsd:restriction>
       
</xsd:simpleType>
     
</xsd:element>
     
<xsd:element name="operational">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:string">
           
<xsd:enumeration value="Emergency"/>
           
<xsd:enumeration value="Other Operational Outage"/>
           
<xsd:enumeration value="System Operating Limit Mitigation, ex Voltage"/>
           
<xsd:enumeration value="System Voltage Limit Mitigation"/>
           
<xsd:enumeration value="N/A"/>
           
<xsd:enumeration value="Human Error"/>
         
</xsd:restriction>
       
</xsd:simpleType>
     
</xsd:element>
     
<xsd:element name="autoReclose">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="faultType">
             
<xsd:simpleType>
               
<xsd:restriction base="xsd:integer">
                 
<xsd:minInclusive value="0"/>
                 
<xsd:maxInclusive value="5"/>
               
</xsd:restriction>
             
</xsd:simpleType>
           
</xsd:element>
           
<xsd:element name="outageInitCode">
             
<xsd:simpleType>
               
<xsd:restriction base="xsd:integer">
                 
<xsd:minInclusive value="0"/>
                 
<xsd:maxInclusive value="5"/>
               
</xsd:restriction>
             
</xsd:simpleType>
           
</xsd:element>
           
<xsd:element name="initCauseCode">
             
<xsd:simpleType>
               
<xsd:restriction base="xsd:integer">
                 
<xsd:minInclusive value="0"/>
                 
<xsd:maxInclusive value="17"/>
               
</xsd:restriction>
             
</xsd:simpleType>
           
</xsd:element>
           
<xsd:element name="sustainedCauseCode">
             
<xsd:simpleType>
               
<xsd:restriction base="xsd:integer">
                 
<xsd:minInclusive value="0"/>
                 
<xsd:maxInclusive value="18"/>
               
</xsd:restriction>
             
</xsd:simpleType>
           
</xsd:element>
           
<xsd:element name="outageModeCode">
             
<xsd:simpleType>
               
<xsd:restriction base="xsd:integer">
                 
<xsd:minInclusive value="0"/>
                 
<xsd:maxInclusive value="5"/>
               
</xsd:restriction>
             
</xsd:simpleType>
           
</xsd:element>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
   
</xsd:choice>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/nerctads/planned
diagram transticreview_p80.png
type restriction of xsd:string
properties
content simple
facets
Kind Value Annotation
enumeration Maintenance and Construction
enumeration Other Planned Outage
enumeration Third Party Request
source <xsd:element name="planned">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:string">
     
<xsd:enumeration value="Maintenance and Construction"/>
     
<xsd:enumeration value="Other Planned Outage"/>
     
<xsd:enumeration value="Third Party Request"/>
   
</xsd:restriction>
 
</xsd:simpleType>
</xsd:element>

element edart/transticreview/nerctads/operational
diagram transticreview_p81.png
type restriction of xsd:string
properties
content simple
facets
Kind Value Annotation
enumeration Emergency
enumeration Other Operational Outage
enumeration System Operating Limit Mitigation, ex Voltage
enumeration System Voltage Limit Mitigation
enumeration N/A
enumeration Human Error
source <xsd:element name="operational">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:string">
     
<xsd:enumeration value="Emergency"/>
     
<xsd:enumeration value="Other Operational Outage"/>
     
<xsd:enumeration value="System Operating Limit Mitigation, ex Voltage"/>
     
<xsd:enumeration value="System Voltage Limit Mitigation"/>
     
<xsd:enumeration value="N/A"/>
     
<xsd:enumeration value="Human Error"/>
   
</xsd:restriction>
 
</xsd:simpleType>
</xsd:element>

element edart/transticreview/nerctads/autoReclose
diagram transticreview_p82.png
properties
content complex
children faultType outageInitCode initCauseCode sustainedCauseCode outageModeCode
source <xsd:element name="autoReclose">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="faultType">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:integer">
           
<xsd:minInclusive value="0"/>
           
<xsd:maxInclusive value="5"/>
         
</xsd:restriction>
       
</xsd:simpleType>
     
</xsd:element>
     
<xsd:element name="outageInitCode">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:integer">
           
<xsd:minInclusive value="0"/>
           
<xsd:maxInclusive value="5"/>
         
</xsd:restriction>
       
</xsd:simpleType>
     
</xsd:element>
     
<xsd:element name="initCauseCode">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:integer">
           
<xsd:minInclusive value="0"/>
           
<xsd:maxInclusive value="17"/>
         
</xsd:restriction>
       
</xsd:simpleType>
     
</xsd:element>
     
<xsd:element name="sustainedCauseCode">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:integer">
           
<xsd:minInclusive value="0"/>
           
<xsd:maxInclusive value="18"/>
         
</xsd:restriction>
       
</xsd:simpleType>
     
</xsd:element>
     
<xsd:element name="outageModeCode">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:integer">
           
<xsd:minInclusive value="0"/>
           
<xsd:maxInclusive value="5"/>
         
</xsd:restriction>
       
</xsd:simpleType>
     
</xsd:element>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/nerctads/autoReclose/faultType
diagram transticreview_p83.png
type restriction of xsd:integer
properties
content simple
facets
Kind Value Annotation
minInclusive 0
maxInclusive 5
source <xsd:element name="faultType">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:integer">
     
<xsd:minInclusive value="0"/>
     
<xsd:maxInclusive value="5"/>
   
</xsd:restriction>
 
</xsd:simpleType>
</xsd:element>

element edart/transticreview/nerctads/autoReclose/outageInitCode
diagram transticreview_p84.png
type restriction of xsd:integer
properties
content simple
facets
Kind Value Annotation
minInclusive 0
maxInclusive 5
source <xsd:element name="outageInitCode">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:integer">
     
<xsd:minInclusive value="0"/>
     
<xsd:maxInclusive value="5"/>
   
</xsd:restriction>
 
</xsd:simpleType>
</xsd:element>

element edart/transticreview/nerctads/autoReclose/initCauseCode
diagram transticreview_p85.png
type restriction of xsd:integer
properties
content simple
facets
Kind Value Annotation
minInclusive 0
maxInclusive 17
source <xsd:element name="initCauseCode">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:integer">
     
<xsd:minInclusive value="0"/>
     
<xsd:maxInclusive value="17"/>
   
</xsd:restriction>
 
</xsd:simpleType>
</xsd:element>

element edart/transticreview/nerctads/autoReclose/sustainedCauseCode
diagram transticreview_p86.png
type restriction of xsd:integer
properties
content simple
facets
Kind Value Annotation
minInclusive 0
maxInclusive 18
source <xsd:element name="sustainedCauseCode">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:integer">
     
<xsd:minInclusive value="0"/>
     
<xsd:maxInclusive value="18"/>
   
</xsd:restriction>
 
</xsd:simpleType>
</xsd:element>

element edart/transticreview/nerctads/autoReclose/outageModeCode
diagram transticreview_p87.png
type restriction of xsd:integer
properties
content simple
facets
Kind Value Annotation
minInclusive 0
maxInclusive 5
source <xsd:element name="outageModeCode">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:integer">
     
<xsd:minInclusive value="0"/>
     
<xsd:maxInclusive value="5"/>
   
</xsd:restriction>
 
</xsd:simpleType>
</xsd:element>

element edart/transticreview/datelogs
diagram transticreview_p88.png
properties
minOcc 0
maxOcc 1
content complex
children datelog
source <xsd:element name="datelogs" minOccurs="0">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="datelog" minOccurs="0" maxOccurs="unbounded">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element ref="interval_definition"/>
           
<xsd:element name="timestamp" type="xsd:string"/>
           
<xsd:element name="currentFlag" type="xsd:integer"/>
           
<xsd:element name="user" type="xsd:string"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/datelogs/datelog
diagram transticreview_p89.png
properties
minOcc 0
maxOcc unbounded
content complex
children interval_definition timestamp currentFlag user
source <xsd:element name="datelog" minOccurs="0" maxOccurs="unbounded">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element ref="interval_definition"/>
     
<xsd:element name="timestamp" type="xsd:string"/>
     
<xsd:element name="currentFlag" type="xsd:integer"/>
     
<xsd:element name="user" type="xsd:string"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/datelogs/datelog/timestamp
diagram transticreview_p90.png
type xsd:string
properties
content simple
source <xsd:element name="timestamp" type="xsd:string"/>

element edart/transticreview/datelogs/datelog/currentFlag
diagram transticreview_p91.png
type xsd:integer
properties
content simple
source <xsd:element name="currentFlag" type="xsd:integer"/>

element edart/transticreview/datelogs/datelog/user
diagram transticreview_p92.png
type xsd:string
properties
content simple
source <xsd:element name="user" type="xsd:string"/>

element edart/transticreview/rtepQueueNumber
diagram transticreview_p93.png
type restriction of xsd:string
properties
minOcc 0
maxOcc 1
content simple
facets
Kind Value Annotation
maxLength 50
source <xsd:element name="rtepQueueNumber" minOccurs="0">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:string">
     
<xsd:maxLength value="50"/>
   
</xsd:restriction>
 
</xsd:simpleType>
</xsd:element>

element edart/transticreview/totalConflicts
diagram transticreview_p94.png
type xsd:integer
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="totalConflicts" type="xsd:integer" minOccurs="0"/>

element edart/transticreview/unmitigatedConflicts
diagram transticreview_p95.png
type xsd:integer
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="unmitigatedConflicts" type="xsd:integer" minOccurs="0"/>

element edart/transticreview/company_actuals
diagram transticreview_p96.png
properties
minOcc 0
maxOcc 1
content complex
children interval_definition
source <xsd:element name="company_actuals" minOccurs="0">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="interval_definition" maxOccurs="unbounded">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="interval_start">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element ref="date"/>
                 
<xsd:element ref="time"/>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
           
<xsd:element name="interval_end" minOccurs="0">
             
<xsd:complexType>
               
<xsd:sequence>
                 
<xsd:element ref="date"/>
                 
<xsd:element ref="time"/>
               
</xsd:sequence>
             
</xsd:complexType>
           
</xsd:element>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/company_actuals/interval_definition
diagram transticreview_p97.png
properties
minOcc 1
maxOcc unbounded
content complex
children interval_start interval_end
used by
elements edart/transticreview/active_dates edart/transticreview/datelogs/datelog edart/transticreview/equipment edart/transticreview
source <xsd:element name="interval_definition" maxOccurs="unbounded">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="interval_start">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element ref="date"/>
           
<xsd:element ref="time"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="interval_end" minOccurs="0">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element ref="date"/>
           
<xsd:element ref="time"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/company_actuals/interval_definition/interval_start
diagram transticreview_p98.png
properties
content complex
children date time
source <xsd:element name="interval_start">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element ref="date"/>
     
<xsd:element ref="time"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/company_actuals/interval_definition/interval_end
diagram transticreview_p99.png
properties
minOcc 0
maxOcc 1
content complex
children date time
source <xsd:element name="interval_end" minOccurs="0">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element ref="date"/>
     
<xsd:element ref="time"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/fileAttachmentCount
diagram transticreview_p100.png
type xsd:unsignedInt
properties
minOcc 0
maxOcc 1
content simple
source <xsd:element name="fileAttachmentCount" type="xsd:unsignedInt" minOccurs="0"/>

element edart/transticreview/fileList
diagram transticreview_p101.png
properties
minOcc 0
maxOcc 1
content complex
children file
source <xsd:element name="fileList" minOccurs="0">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="file" maxOccurs="unbounded">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element name="fileName" type="xsd:string"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/fileList/file
diagram transticreview_p102.png
properties
minOcc 1
maxOcc unbounded
content complex
children fileName
source <xsd:element name="file" maxOccurs="unbounded">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="fileName" type="xsd:string"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/fileList/file/fileName
diagram transticreview_p103.png
type xsd:string
properties
content simple
source <xsd:element name="fileName" type="xsd:string"/>

element edart/transticreview/fileAttachments
diagram transticreview_p104.png
properties
minOcc 0
maxOcc 1
content complex
children attachment
source <xsd:element name="fileAttachments" minOccurs="0">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="attachment" type="xsd:string" maxOccurs="unbounded"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element edart/transticreview/fileAttachments/attachment
diagram transticreview_p105.png
type xsd:string
properties
minOcc 1
maxOcc unbounded
content simple
source <xsd:element name="attachment" type="xsd:string" maxOccurs="unbounded"/>

element edart/transticreview/equipment_default
diagram transticreview_p106.png
type equipment_default
properties
content complex
children equipment
source <xsd:element name="equipment_default" type="equipment_default"/>

element edart/transticreview/takeout_restore
diagram transticreview_p107.png
type takeout_restore
properties
content complex
children equipment
source <xsd:element name="takeout_restore" type="takeout_restore"/>

element edart/transticreview/restplan
diagram transticreview_p108.png
type restplan
properties
minOcc 0
maxOcc 1
content complex
children restplanreview
source <xsd:element name="restplan" type="restplan" minOccurs="0"/>

element interval_definition
diagram transticreview_p109.png
properties
content complex
children interval_start interval_end
used by
elements edart/transticreview/active_dates edart/transticreview/datelogs/datelog edart/transticreview/equipment edart/transticreview
source <xsd:element name="interval_definition">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element name="interval_start">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element ref="date"/>
           
<xsd:element ref="time"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
     
<xsd:element name="interval_end" minOccurs="0">
       
<xsd:complexType>
         
<xsd:sequence>
           
<xsd:element ref="date"/>
           
<xsd:element ref="time"/>
         
</xsd:sequence>
       
</xsd:complexType>
     
</xsd:element>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element interval_definition/interval_start
diagram transticreview_p110.png
properties
content complex
children date time
source <xsd:element name="interval_start">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element ref="date"/>
     
<xsd:element ref="time"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element interval_definition/interval_end
diagram transticreview_p111.png
properties
minOcc 0
maxOcc 1
content complex
children date time
source <xsd:element name="interval_end" minOccurs="0">
 
<xsd:complexType>
   
<xsd:sequence>
     
<xsd:element ref="date"/>
     
<xsd:element ref="time"/>
   
</xsd:sequence>
 
</xsd:complexType>
</xsd:element>

element time
diagram transticreview_p112.png
type xsd:string
properties
content simple
used by
elements edart/transticreview/company_actuals/interval_definition/interval_end interval_definition/interval_end conflict/scenario/potential_gap/interval_end edart/transticreview/company_actuals/interval_definition/interval_start interval_definition/interval_start conflict/scenario/potential_gap/interval_start
source <xsd:element name="time" type="xsd:string"/>

complexType equipment_default
diagram transticreview_p113.png
children equipment
used by
element edart/transticreview/equipment_default
source <xsd:complexType name="equipment_default">
 
<xsd:choice minOccurs="0" maxOccurs="unbounded">
   
<xsd:element name="equipment">
     
<xsd:complexType>
       
<xsd:all>
         
<xsd:element name="default_status" type="xsd:string"/>
       
</xsd:all>
       
<xsd:attribute name="ta_id" type="xsd:long" use="required"/>
     
</xsd:complexType>
   
</xsd:element>
 
</xsd:choice>
</xsd:complexType>

element equipment_default/equipment
diagram transticreview_p114.png
properties
content complex
children default_status
attributes
Name  Type  Use  Default  Fixed  Annotation
ta_id  xsd:long  required      
source <xsd:element name="equipment">
 
<xsd:complexType>
   
<xsd:all>
     
<xsd:element name="default_status" type="xsd:string"/>
   
</xsd:all>
   
<xsd:attribute name="ta_id" type="xsd:long" use="required"/>
 
</xsd:complexType>
</xsd:element>

attribute equipment_default/equipment/@ta_id
type xsd:long
properties
use required
source <xsd:attribute name="ta_id" type="xsd:long" use="required"/>

element equipment_default/equipment/default_status
diagram transticreview_p115.png
type xsd:string
properties
content simple
source <xsd:element name="default_status" type="xsd:string"/>

complexType FileList
diagram transticreview_p116.png
children fileName
used by
element ModelingRequest/fileList
source <xsd:complexType name="FileList">
 
<xsd:sequence>
   
<xsd:element name="fileName" type="xsd:string" minOccurs="0" maxOccurs="unbounded"/>
 
</xsd:sequence>
</xsd:complexType>

element FileList/fileName
diagram transticreview_p117.png
type xsd:string
properties
minOcc 0
maxOcc unbounded
content simple
source <xsd:element name="fileName" type="xsd:string" minOccurs="0" maxOccurs="unbounded"/>

complexType modeling_requests
diagram transticreview_p118.png
children modeling_request
used by
element edart/transticreview/modeling_requests
source <xsd:complexType name="modeling_requests">
 
<xsd:sequence>
   
<xsd:element name="modeling_request" type="ModelingRequest" minOccurs="0" maxOccurs="unbounded"/>
 
</xsd:sequence>
</xsd:complexType>

element modeling_requests/modeling_request
diagram transticreview_p119.png
type ModelingRequest
properties
minOcc 0
maxOcc unbounded
content complex
children title rtep_queue_number company_name status build fileList
attributes
Name  Type  Use  Default  Fixed  Annotation
id  xsd:long  required      
source <xsd:element name="modeling_request" type="ModelingRequest" minOccurs="0" maxOccurs="unbounded"/>

complexType ModelingRequest
diagram transticreview_p120.png
children title rtep_queue_number company_name status build fileList
used by
element modeling_requests/modeling_request
attributes
Name  Type  Use  Default  Fixed  Annotation
id  xsd:long  required      
source <xsd:complexType name="ModelingRequest">
 
<xsd:sequence>
   
<xsd:element name="title" type="xsd:string"/>
   
<xsd:element name="rtep_queue_number" type="xsd:string"/>
   
<xsd:element name="company_name" type="xsd:string"/>
   
<xsd:element name="status" type="xsd:string"/>
   
<xsd:element name="build" type="xsd:string"/>
   
<xsd:element name="fileList" type="FileList"/>
 
</xsd:sequence>
 
<xsd:attribute name="id" type="xsd:long" use="required"/>
</xsd:complexType>

attribute ModelingRequest/@id
type xsd:long
properties
use required
source <xsd:attribute name="id" type="xsd:long" use="required"/>

element ModelingRequest/title
diagram transticreview_p121.png
type xsd:string
properties
content simple
source <xsd:element name="title" type="xsd:string"/>

element ModelingRequest/rtep_queue_number
diagram transticreview_p122.png
type xsd:string
properties
content simple
source <xsd:element name="rtep_queue_number" type="xsd:string"/>

element ModelingRequest/company_name
diagram transticreview_p123.png
type xsd:string
properties
content simple
source <xsd:element name="company_name" type="xsd:string"/>

element ModelingRequest/status
diagram transticreview_p124.png
type xsd:string
properties
content simple
source <xsd:element name="status" type="xsd:string"/>

element ModelingRequest/build
diagram transticreview_p125.png
type xsd:string
properties
content simple
source <xsd:element name="build" type="xsd:string"/>

element ModelingRequest/fileList
diagram transticreview_p126.png
type FileList
properties
content complex
children fileName
source <xsd:element name="fileList" type="FileList"/>

complexType restplan
diagram transticreview_p127.png
children restplanreview
used by
element edart/transticreview/restplan
source <xsd:complexType name="restplan">
 
<xsd:sequence>
   
<xsd:element name="restplanreview" type="xsd:string"/>
 
</xsd:sequence>
</xsd:complexType>

element restplan/restplanreview
diagram transticreview_p128.png
type xsd:string
properties
content simple
source <xsd:element name="restplanreview" type="xsd:string"/>

complexType takeout_restore
diagram transticreview_p129.png
children equipment
used by
element edart/transticreview/takeout_restore
source <xsd:complexType name="takeout_restore">
 
<xsd:choice minOccurs="0" maxOccurs="unbounded">
   
<xsd:element name="equipment">
     
<xsd:complexType>
       
<xsd:all>
         
<xsd:element name="status">
           
<xsd:simpleType>
             
<xsd:restriction base="xsd:NMTOKEN">
               
<xsd:enumeration value="T"/>
               
<xsd:enumeration value="R"/>
               
<xsd:enumeration value="TR"/>
             
</xsd:restriction>
           
</xsd:simpleType>
         
</xsd:element>
       
</xsd:all>
       
<xsd:attribute name="ta_id" type="xsd:long" use="required"/>
     
</xsd:complexType>
   
</xsd:element>
 
</xsd:choice>
</xsd:complexType>

element takeout_restore/equipment
diagram transticreview_p130.png
properties
content complex
children status
attributes
Name  Type  Use  Default  Fixed  Annotation
ta_id  xsd:long  required      
source <xsd:element name="equipment">
 
<xsd:complexType>
   
<xsd:all>
     
<xsd:element name="status">
       
<xsd:simpleType>
         
<xsd:restriction base="xsd:NMTOKEN">
           
<xsd:enumeration value="T"/>
           
<xsd:enumeration value="R"/>
           
<xsd:enumeration value="TR"/>
         
</xsd:restriction>
       
</xsd:simpleType>
     
</xsd:element>
   
</xsd:all>
   
<xsd:attribute name="ta_id" type="xsd:long" use="required"/>
 
</xsd:complexType>
</xsd:element>

attribute takeout_restore/equipment/@ta_id
type xsd:long
properties
use required
source <xsd:attribute name="ta_id" type="xsd:long" use="required"/>

element takeout_restore/equipment/status
diagram transticreview_p131.png
type restriction of xsd:NMTOKEN
properties
content simple
facets
Kind Value Annotation
enumeration T
enumeration R
enumeration TR
source <xsd:element name="status">
 
<xsd:simpleType>
   
<xsd:restriction base="xsd:NMTOKEN">
     
<xsd:enumeration value="T"/>
     
<xsd:enumeration value="R"/>
     
<xsd:enumeration value="TR"/>
   
</xsd:restriction>
 
</xsd:simpleType>
</xsd:element>


XML Schema documentation generated by XMLSpy Schema Editor http://www.altova.com/xmlspy