Updated New Service Request Due Dates

For Attachments N, S, EE, Y, and BB, New Service Requests will not be accepted during the period of March 11–31 and September 11–30. For Attachments PP and RR, there is no change in the New Service Request submission period. Please see Manual 14A, Section 2.3, for additional details.

New Service Requests

Queue Point

All new interconnection service requests must be submitted through the Queue Point tool.

Failing to submit a complete interconnection request and/or missing the various interconnection request due dates as set forth in the Open Access Transmission Tariff may result in your interconnection request being terminated and withdrawn. Please see Part IV of the Tariff PDF for interconnection request submittal and/or deficiency review details.

User Guide PDF
Queue Point - Share Feature Quick Guide PDF
Sign in | Register
Calculate your deposit for Attachment N, S, Y & RR 

Submit data for:

  • Generation Interconnection
  • Transmission Interconnection
  • Incremental Auction Revenue Rights upgrades
  • Generation interconnection of 2 megawatts or less
  • Interconnection service agreements for certified inverter-based generating facility
  • System impact studies
  • As-built studies

Pre-Application for Small Generation Interconnection Request

Informal Request – Generators less than or equal to 20 megawatts maximum facility output can request PJM to provide information on proposed jurisdictional circuits by emailing the System Planning Administrator.

Formal Request – Pre-Application Request PDF - Print & complete the form and email it to the System Planning Administrator. Mail the necessary payment to:

PJM Interconnection, LLC Transmission Planning
PO Box 825682
Philadelphia, PA 19182-5682

Any questions call (610) 666-2312.

Generation Construction Phase

Exhibit 6: Transmission Owner Standard Invoice Form F XLS
Exhibit 5: Interconnection Service Agreement/Interconnection Construction Service Agreement Scope Change Form XLS 

Consent to Assignment Agreement Templates


Project Assignment PJM Contact Consent Documents
Prior to Interconnection Service Agreement, Wholesale Market Participant Agreement or Upgrade Construction Service Agreement execution
Interconnection projects project manager
Notice to PJM:
Combined buyer seller DOC
Seller DOC
Buyer DOC
After ISA and prior to commercial operation (i.e. during construction)
Infrastructure coordination project manager

Assignment to:
Lenders DOC
Other Than Lenders:
IC | TO DOC
Agreement to Amend per Assignment without Prior Consent Template DOC
Consent to Assignment and Agreement to Amend Template DOC

After commercial operation1
PJM client manager

1Generator owners or merchant transmission facility owners that wish to assign their facility to another entity or to perform a lender transfer after commercial operation shall follow the following instructions: 

Notify your intent to your PJM client manager a minimum of 90 days prior to the financial transfer to assure adequate time to make necessary agreement modifications and filings with the Federal Energy Regulatory Commission.

Identify to PJM all existing underlying affected agreements, such as Power Purchase Agreements, two-party interconnection agreements, PJM Interconnection service agreements; and

Identify any changes to the facility that have occurred since the current effective agreement was executed that are not currently documented in the existing agreement, such as scope change documents from construction, retirements of units depictured or described in the agreement, modifications to the facility that would be reflected on a one-line diagram. 

PJM will review the proposed assignment and existing agreements to determine the proper documentation and filings necessary to effectuate the requested asset transfer or lender change.

For more information on deposits, please refer to the Open Access Transmission Tariff.

Contact

(866) 400-8980
(610) 666-8980
Member Relations

Training Video | User Guide PDF

Training

Interconnection Customer FAQs 
Interconnection Service Agreement (ISA) Education
Membership & Market Participation Requirements for Generation Interconnection Process PDF
Pre-Queue Education

Manuals

M-14 series - specific business rules under which PJM affects the entire regional transmission expansion planning (RTEP) process, including the details associated with the scope and procedures associated with the planning results and upgrades described in this report

Agreements

Operating Agreement WEB | PDF - Schedule 6
Open Access Transmission Tariff WEB | PDF
- describes the interconnection request process for generating resource interconnection, merchant transmission interconnection as well as specific process provisions to address long-term firm transmission service and auction revenue rights.

PJM’s competitive planning process resources provide RTEP stakeholders the business rules, methodologies and tools necessary to implement Operating Agreement, schedule 6 transmission planning process enhancements and Open Access Transmission Tariff, schedule 12 reforms.

Business Forms & Instructions

Agreement to Amend Template DOC
Confirming Letter of Credit for Interconnection Agreements - Version 2 - Effective 4.2.2021 DOC
Letter of Credit Form DOC
Transmission Owner/Generation Owner Phasor Device Registry Form XLS
Transmission Owner Notice of Completion of Construction - Template DOC
Wholesale Market Participant Agreement Construction Information PDF

Stakeholder Groups

Transmission Expansion Advisory Committee